HomeMy WebLinkAbout15-16271 CITY OF ZEPHYRHILLS
; � ; 5335-8TH STREET
(si3)�so-oozo 16271
BUILDING PERMIT
PERMIT INFORMATION LOCATION INFORMATION
Permit Number: 16271 Address: 5222 19TH ST
Permit Type: ADDITION/ALTERATION ZEPHYRHILLS, FL.
Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Square Feet: Subdivision: CITY OF ZEPHYRHILLS
Est. Value: Parcel Number: 11-26-21-0010-19900-0010
Improv. Cost: 1,900.00 OWNER INFORMATION
Date Issued: 5/18/2015 Name: MCLEOD, ASHLEY& LARRAMORE, JOS
Total Fees: 187.50 Address: 5222 19TH ST
Amount Paid: 187.50 ZEPHYRHILLS, FL. 33542 �
Date Paid: 5/18/2015 �c► Phone: (813)714-6569
Work Desc: GARAGE CONVERT TO B�@idl 287 SQ FT Q j� -/ - �
CONTRACTOR S APPLICATION FE S
H M OWNER BUILDING FEE 67.50 ELECTRICAL FEE 60.00
HOMEOWNER MECHANICAL FEE 60.00
HOMEOWNER
� n .
� L
�
z�
.c�
Ins ections Re uired
FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
', ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
' DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
.
REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c)when extra inspection
� trips are necessary due to any one of the following reasons: a)wrong address b) condemned work resulting
' from faulty construction c) repairs or corrections not made when inspections called d) work not ready for
inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with
City Codes and Ordinances. NO OCCUPANCY BEFO C.O.
CO CTOR SIGNATURE PERMIT OFFI R
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
i
1
� . .
�•� [�r
!{.< F?':3";
f�37��yfj;y f�
��7'!�1
�'
"�r. „ , '
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner: ����l���-�
Date Received: �—���jr
Site: SZZL � �~ �z.r� e%�`�'�`�G���c�-
Permit Type: �0 y��/(:��� �7/ �i? S�.� "
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑
��� ,;:/� ,t q�
' ���� k'/ 1�"��r�'`✓ � �'� �-T � �:,�''�d;'� �-7 r✓i�
a
r�i r� �� �;:-i ����cr�. C�—L�- l �` � �
��,
��
This comment sheet shall be kept with the permit and/or plans.
, '
/l / � '� L
�
Kalvin S 'tzer— x mer Date � Contractor and/or o eowner
(Required when co ments are present)
�
o ` �s�aaeaoozo City of Zephyrhills Permit Application F�-si�-�eaooz�
� Building Department �
;
� Date Received {3 I 3 ��3 �G��
Phone ConWct for Pertnitting
' OwnersName � .` �SNL�y �AZCplrwa OwnerPhoneNumber 8l3 — 3.73- (G .�.7
� t—�: a 9 7N - �.T
Owners Address J a � J�i�Fi Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address
JOBADDRESS Sr��'� I��µ ST12E�LT L TO # � .
SUBDIVISION PARCEL ID#
(OBTAINED FROM PROPERTY TAl(NOTICE)
WORK PROPOSED B NEW CONSTR� ADD/ALT 0 SIGN Q Q DEMOLISH
� INSTALL REPAIR
� PROPOSEDUSE Q SFR Q COMM 0 OTHER �Jg�Q10�2 ulL �aJ�
TYPE OF CONSTRUCTION � BLOCK Q FRAME STEEL Q
DESCRIP110N OF WORK CD JE�S � T� D12 ao�— S �—l ��
BUILDING SIZE ��� S I r SQ FOOTAGE� HEIGHT � �_L[1��1 1
mBUILDING $ ' �0O VALUATION OF TOTAL CONSTRUCTION
QELECTRICAL $ AMP SERVICE Q PROGRESS ENERGY Q W.R.E.C.
.
QPLUMBING $ n ,_ � _
i �/f/` 1
QMECHANICAL $ VALUATION OF MECHANICAL INSTALLATION (� C
V
�
QGAS Q ROOFING Q SPECIALTY Q OTHER , �
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA QYES NO "����
�
b��t� BUILDER �A� tt►Z � 7 \
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address � �9 5 i SLE£T License#
�
ELECTRICIAN �Q a(,�+ COMPANY
SIGNATURE l REGISTERED Y/ N FEE CURRE� Y/N
Address License#
PLUMBER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address �� License#
M\ . 1
' MECHANICAL �. COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREA Y/N
Address License#
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address License#
t111t111111111111t1111111111111111111i11111111111111111111111111111
RESIDENTIAL Attach(2)Plot Pians;(2)sets of 8uilding Plans;(1)set of Energy Fortns;R-O-W Pertnit for new consWCtion,
Minimum ten(10)worlting days after submittal date. Required onsite,ConsVuction Plans,Stortnwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster,Site Work Pertnit for subdivisionsJlarge projects
COMMERCIAL Attach(3)complete sels of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Pertnit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Starmwaler Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster Site Work Pertnit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
""PROPERTY SURVEY required for all NEW construclion. I
Directions:•
Fill out applicaUon completely
Owner&ConUactor sign back of application,notarized
If over$2500,a Nodce of Commencement is required. (AIC upgrades over$7500)
" Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from awner authorizing same
OVER THE COUNTER PERMITIING (Front of Application Only)
Reroofs'rf shingles Sewers Service Upgrades A/C Fences(PIoUSurvey/Footage) .
Driveways-Not over Counter'rf on public roadways..needs ROW
_ J
�
� � NOTICE OF DEED RESTRICTIONS: The undersigned understands that this pe�mit may be subject to"deed"restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
' applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the
, contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
� under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the
contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands,that such fees, as may be due,will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
� receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or
final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County WateNSewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner"prior to commencement. '
CONTRACTOR'S/OWNER'S AFFIDAVIT. I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands,Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls,Docks,Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone"V"unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a '
"compensating volume"will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction,I certify that fill will be used only to fill the area within the stem wall.
' - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating
the cond'itions of the building permit issued under the attached permit application,for lots less than one (1)
acre which are elevated by fill,an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
_, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the appiication. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or
'� � � set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter
��°,�o requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid
,�e�i� unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
�:y�� the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension
�� � may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate
' �� justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned.
� � WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
�� PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S.117.03)
� � OWNERORAGENT�Wct.l l [.�C�G(`��C(� CONTRACTOR
Nw;� Sub nd sw m to(or affirm )befo�r [�e this Subscribed and sworn to(or affirmed)before me this
• �,N,y� rv�t...�, 'Z..t�\0 by
Who is/are personally nown t e or has/have produced Who is/are personally known to me or hasRiave produced
► a: �_11':J.�f'1 as identification. as idenfification.
1'�•'
,,,14pM;`, .���i'�!
Notary Public Notary Public
Commission No. �`1���; Commission No.
..` otary typed, AM�f�� Name of Notary typed,printed or stamped
�� IlOiify ItbNC•Slile o1 Flor�d:
'• Mry►Conlm.Eq�May 23,:::�
'"' ConMlllltl0�o�iF 111536
,':,'��a�t��a BOf�dlhalalM�lOIIrNOIayl�SSn.�
,,: -- ; � '
FoRAns
fLOR�dA BUILDIfdG�ODE;ENERt3Y CONSEFiVA`I'ION
FOAld.402-2010 ResideMisi Buildiqg The?met Emretupe Appmach ALL�.IMA7E 20NES
Ssapa:Compliance with 5ection 4D2 of the Florida.Bvildiag Code,Ereipy Lbnssnrdhon,'shall.be demoostrated by the use of Fonn.402 for�ing�e-and mattiplafamily tesidences of ihree
srones or less in height,additirn�s ioezisUng reside�l buildings,rennvatlans to ex�tmg�eside�ial buildlngs newr heatir�coo6n�,and waterheating sysiems�n e�dsting�buAd'mgs as
�pp�le.To campty,a 6uiMing must ineet or exceed altnf llIe energy e�icfency iegunelpents on Ta6k 4020.ai�allapplicable man�tay reqolremenCS Sumrrrar¢ed in Takle 4028 a�thk
form.I(.e huilding does notcompiy w�h Nqs method or AUernate Form 402;It may.�i11.co�npiy dader S¢ctiun 4D5 of theHpdda 8ullding Gode,.Energy Cansenatian.
PROJECTNAME: -:Lefr2�i10�2 eunn�: Owner
AND ADDRESS: 522.2 19t�1 St P�ppq7�7py�
-Zephyrhilis,FL 33542 aF�iCE: City of Zephyrhills
OYVNER: Josh&Ashley Larram9re F�aMtrNO.: � z?l JURISDlCi1pNN0:: 61'I6O0
Ge�al lnsti'udines:
t:Ne�a cotistn�etian wt�ich inco�oraies anY af the totlowkm teatu�es cannot eompiy us�g thls meihod:gtass areas In Bzcess ut 20 t ai caid�tioned ttoor area,ele�tr�resishen�e
a
heatand ait fiandlers iocaFed in ttics.'AddIqO�S 6U8.�.$.,retlavefiora atW equ(p�ntebadgewds roayaomply.ity this meth kNh o�r:epiinna ptven.
2 Fdt irt aq the appupMe,spaces.oi tt�a"fo Be Itistallsd`�alumn on Teble 4lYlA wtth Ure IRfor(nat)on reqttested,A►I'7o Be Imstalled"i21Ues tt�us��e equatto or inore efficient 5hen the �
required f�els.
3;Complete�ge 7 baSed oq tlre'7o 9e Insmlted"column Gitom�atian:
4.Read fhe requirements:of Table 902B and ct�eck eacR bmc m ind�caDe ywr intent io compty with all appikable items.
5:.Read,sign ahd date.the"Psepared 6��cecdfirdtlonslammem af tha botmm ofi pape 7:The a�vner or awrte�s agertt mustsiSO Sfgn�nd dai�tha fbrm.
Flea�e Pmit CIC
t. Nenv codstruCBon,addiUon,ot exTs6ng building �, Addition
2 Singi��family detacheit or riiultiple-tam9ly attached g Detached
3, lf muftiple�amity-rlo.of.ufiit�copered bythis submission �
4. fsthis e warst case?(yeslno) : 4. No
3. Cand+tione+dfborarea(sqrR.) 5; 287_
� 6. Gfass.type and area: `
e..U-faccoi 6a. 0.65
b.SHGC �b. .�� �
a Glass area sc. .. 'I 2 sq.R
7. Pereentage of gEass W rioor area 7 4.2 y, �
� e. Floor type,area or perimetey 8nd insutadon:
a steb-on-grade(x-vqtue} Sa.R- � 35.5 Iln.tt
b.Wood.:aiscd(R-valae) Sb.R= Sq,ft
a.W"oqd.cantmon(12-value) 80.R=. sq.R
d.Conrrcce,ruisat(R YalurJ 8d.R= sq;it �
, t.Condae..com�non(R-vaAie) 8e.xi= sq.ft
9, .Wafl type,s(ea�1d lnsulat�qn:
a.Fxterior: I, Masonry.(InsulappnR-va�ue) �.1, p_ 7,$ 284
2. WaodPrame(Lts�ationR-value) ' �2 �_ �:,� -
b.Adjacena 1. Maso�ty(InsulationR'value7 g��, q_ ��
2. Wood&ame(InsnladonR-value) 9b-2.R=
sq.[L
10. Ceilingtype,steaendinstilation:
aUndcrmtic:(InsalaricmRvame) 10a.R= 30 -,q.n 28$
b.Single asstmbly(Insula[ion R-value� 'f Oh.p= �q.�
it. AIr�istrf4ution 8ystem:pelct i�uiation,tocation,Qn
&.I7dct la�ation,insuJation 918, R=S_�_ AfhC
b-����� 11b. Existma-Attic
c_(�n,Testiepatt 2ttached(c9.03;yeslnoa 1lC.Test raport etlnehed?Yes Nq)(
y� ����� Heat Pum
a.'rype 12e,Type:. . P
b.�ciem.y 12b:SEEH/EER: � i�c stin9
�3. t�eating system: ��;TyPs; Heat Pump
a'ri�pe 13b.HSPF/CQP/AFUE: Existinq�
h Efficiency
S4. ItVAC slzing calcu�tlon:aflached
19. Y��No
Y5. Hot waEer system: •
�,Zyp� t5a.rype: Existing
b.EfHcieucy 75b EF-
i hersbq�ertityihet9�a plans artd speci6cattoru cqverad�ythe ialculaitqn ere in wmptiai�ce ryirti tha qotltla qevlew et plans and speclfirations mve�ed 6yHds��kula6on i�lcffies eomp6ar�caW tn me flwlfla.
Enerpy Cotle. Enarpy Code.Betore consl CO�nQIBf 1111 _�ildiil9 Will h9(�Pfl�1ed foTFalIIDI�Z�IGe li�
PAEPAAEDBY' DATE
3-25-15 �0rdarrcewdhSectlnn553.8 F .
l here6p cerlity Uatihis 6�d1d1�Islatomptiance wllh Iha Flonda Fn¢�qy Code: CDOE OFRGWi: -
OWNEfl A�ifNi:. UATE: 9AT• ' j`
,
�.4 2010 FLORIDA BU DING CODE-ENER6Y CQNSERVAT30N
,�, � 4
FORNlS
Yaa�aoz�
8tlti.Qi[iG COA}FqHENi pERFOAT�IANGE CfitT£RIA' �tSTALLEO V/tLUES:
U�Faclore0.65 �,���_ �.�J�
YllrtdowslseeNate2�: SHOC-Q30 St�c3C� Q.3Q
%OtGPAar2096 W aTGPF=
s u-�ro.<o.rs 4•�
Door,xFx�eHbr4owtYFactor � U-�actorcp65 U-FacWr=.
� l�cor& 5lab-on�gr�OS � . . . . . . . No rsqutiement . . .
{}Y9r uttC00�1iIX76Q i'�1005 is88 idOt6�3 R-13 ����
'wexs-E�it ana A�j.isee Nare 3y: �� .. .
Frartte, H-iS t?-Velue�
N�ss (see Npte�) �
frttetioratvmil: A7.8' A-Vatua.= 7.$
Exterior ot wa1L fl-6 A-Velue=
Cei5ngs{seeNotes3'84) R�80 R-yalug= 80 T��rt
� Raftecbnce U25 Edeflect8�e= At�rhetl7
YestP2a
Air dispi3kilion aystem{sea N#e ay . . - . . .
°�k�`�'��"a��`"���' ��n Existin lAttic 7escreport
thtconiiistaredsPece Nolallovred �
Atffiitted?
Con�§enetlaPaGe' YesiNo
Duct Ft-velue. A-vaNe 2 6 R-Valu9§ 6
AlrteakeBaG7n "G1n50_0.9 �_ �
Rir C07tdN ' #s:�s see Mo1aS 3EER=43A �� SEEF2 0 - (StIY) .. . .
tieaGng system .
I Hea�pump1seeNate� Goolhu� SF.ERe73.0 SEER= Existing
Ft�tlrrc�; H3PF=77 H$PFa Existing
Gas ful»�eee RFUE7896 AfUE�
OR tum3ce. AFUE78% HFUE d
FJeevia rusismnci:�Not�lewed(see Note$j �
Weterheatitgsyskbm{stbrageiype} � - . .
eectuc{seeHOmsa: ao�t�=asz �c�uo�s- Existing
sa�:e�=p.so �_
t3as11red{see(+1cRa 7j. d4 gaY.EF=U.59 �g�q�
Qtlisr tdesctitrs): SOaat:EF=Q.58 EF'
(1)Eaahcompqnent present inttteAS Propasetl hamemustrneetor�tt�9ed�ach ofthe applicaMeperfarmanc�ecrfteaa inptderiocnmglyWiB�thiseode usfngthismethpg•
athersrtisea^er.tlon 405 comp6az�ce»wsi 6e paecl. '
(2)Wi�taws and doors 4uatiiYingagqk^izsd tenectrallon areas must cr�mP�Y-wiqhbWh{hemaximufi 41•Factorand themaxim�sn 9tlGG(solarHeel Gai�Coetficienij r.riteria
and have a maximum t+Dta1 wiadov�.area equa►to or,tess then 26%nf ihe oondi�ohed floor area(CFA);amenvise Sectinn aq5 must be used tor comptiance.
'ExcePiios::A�Uons of 64p square feei#56 r�)ot tess mas!havs a ma�mum glas to CFA Of 5D psiasat
(3}i�-vah3es�ator kssuL�+ttqn matertatonty asappiied�rraccordarica w;t}i inanuta#urers`insFaualion iaswciions.fiormass waAs,ihe`Ynferior of wall'requirefierri mtistbe
met except if st Ceast 50%ot th¢R-B insulatian requ,'ueid for the"�ascterkr dC walP is I�spalled exieriw ot,or Integral.to,the waU:
{4)DucGs&AHU installed suhsianNapy leak tree por SecUon 40322:t_Tesi trQ Glass t BERS rater requtred.
F�cceA�orr-Ducts 3nsta}ted onto an e�stimg air distn'EwGqn systqrrs as p�rt ct&n add�ic4n ar renat�tian;duCY mtist ba R-6 instatted per Sec.508.27.2
' (5)For.ali.conuerrtlonal units with capacHies greaterUmn 3q.oflO.Btuptr For othertppes ai equiprirerrt,see.Tabtes so3.^�9(-1.sj-
Exeeptbn:The prohibition on�fechic resi.staace heat daes nut apply.Yo.aatcjltions,renpvatiohs and�eewr heating systems irmcalleii in�ciSting ku�kiings.
(6}Foz o2hei.elecStc siarage vo3umes.3nlrslt�pm EF`=0.97-(U.Q0182 X va}i�me).
(/y ForqmerimtUtai gas sbxage v6lunres,mirtimam EF=,0.67•(O.OUt9 x:vWUme}.
i
.TABt.@' B PMNOATORYREQUIREAAEN7S � � � -+ .
� COMPQNENTS $ itE4[SIREISlENZS_. ��
TAbB ceutked.ge'sketetl.wexJherstdpped oroll�e�cwisaseatetl.pqcegsed pqnGng IGratatl as mpating iaSiM�.
Ai�leak0g9 4b2.4 2$3.WlrWnwe arM ilooca�D.90 Wm/sq.R.Testing or Wwel inspqaton'requlre0.Fltaplaaes�estceted tloors& 'Y2S
outdoor comlwsUCm a�r.
ce;6�tta�ee wana�� aasa� �R-ta space permnang. � � � N1A
Programmaritelhamm.stat Ao37.t Wbere tomed�air fumate is t�ma�v sYS`tem:a�ammm�a mgrmostac�re�ea N/A
A'ird�triWiiion aysibrn 4032, D�ict,e(n attlw or on robb insuiata!!a H-8:ofhardusis A�,duds lestetl to q,=U.03 4ye Gass r BEAS ratei. IS�{R
ttsat b'aP r�uti8dfasvettka!}sipe risets.,COmpiy wNh ei�cieM�es inTaDte Aa3.4t&Z Pmvtda s+�h or,�eeAy
Watechsetsts 463A ��r�tt��esRer(dac�tic}orstiaMff t9�7.CiieusaHa9systemPipes�iatedfo=a-2+��te,,,arwas E�cisting
' � ' � spas anQ7taaieC poois rriust hava rapnr-rerecasm cwas w a,tlquitl cover oromet meamsproven to.iam�ce haa[
( Slvirnm)npt?ooF&spas 409.9 ;bssp�cep?tt709hafiwaihomate-reCavemdene�gy.ORlUrttersueitci�reqtdrad:Gasheatersmin'vnumihem�a!
� .efrtae =7&% ettertits+ts.Iteat heatersmiinmvmCqP=a.ff.' �IIA
i 9iira,�ca�ulatWti Deitom�f fl atteci�d.NGrrimum stficiandes perTeMes 503.23.EqutpmeM,eFficieiR.yveAtir.a6rn
Coolin0m4P4n9��pn�e�t 403.8 requiMed.Special accesion Fnofiny orlwatirnJ�A�Y�Q��BasePa2m syst�m or vsNeble cepec�r system.
�ElBdrk hBat s"lOkW dxlSt 6a divided rrtto hao ormpre YeS
�9�'+�R9 eiN�DmE�st d04_i iltiess�54%¢f persnaxienfly 3+sraileC Jigtr?tttg tbttieres shaH bar hfgh-e}ficy�y tecr�.
N/A
20i0 6L,ORIDA BUiLDIHG!CODE—ENEiiGY CONSERVATION C.5
�
' - -- -. .. -
� ` ' New Construction
� ���� whole House Worksheet
Customer's Name Josh &Ashley Larramore Address 5222 19th St.
City Zephyrhilis, F� state FL zip 33542 TelephoneNumber .
WINTER: Inside Design Temp 7� deg F -Outside Design Temp 3� deg F = Heating Temp Difference 4� deg F
SUMMER: Outside Design Temp 95 deg F -Inside Design Temp 75 deg F = Cooling Temp Difference 2� deg F
HEATING COMMON DATA SECTION COOLING
HEATING COOLING `
BTUH LOSS FACfOR SU BJ ECT SQ.Ff. FAROR BTUH GAIN
•• GROSS WALL 284 •.
125 DOORS&WINDOWS(Table A or B) 12 264
392 1.44 NET WALL 272 2.3 626
138 0.48 CEILING 287 2.1 603
0 O FLOORS 287 O.O 0
Infihntlon Xeating Volume Volume CmINy Inflkrnion
Btu/Nr - TableD %ID% S 3/6D % (CUFt) �CUft) X I 1/60 X n T % TaWeD - B[u/hr
337 = 0.8 x 0.18333 x 2,296 2,296 x 0.03833 x 20 X 0.4 = 337
992 SUB-TOTAL BTUH LOSS (per 10 deg F)
X 4 ADJUSTMENT FACTOR(Table C)
3,966 TOTAL BTUH LOSS
PEOPLE 2 x 300 BTUH GAIN c"�°'^a��'°°^�Pa�'e'�°°m> 600
' APPLIANCES BTUH ' 0
SUB-TOTAL BTUH GAIN(room sensible oniy) 2,429
x 1.05 DUCT LOSS/GAIN FACTOR(Table F) X 1.1
SUB-TOTAL BTUH(Sensible Gain) 2,672
MOISTURE REMOVAL (sub total x 1.3) x 1.3
4,164 TOTAL BTUH LOSS/GAIN 3,473
TABLE A - HEATING - DOORS&WOOD FRAME WINDOWS TABLE B - COOLING - DOORS&WINDOWS
(PER 10 deg F) Factors assume windows have inside shading by dreperies or venitian
For sliding glass doors use fadors for the same type window blinds and sliding glass doors are treated as windows
construction SINGIEGWSS DOUBIEGlA55 TRIPIEGIASS
Window& Frames xArea =BtuhLoss 7EMV.DIFF. TEMP.OIFF. TEMY.DIfF xArea BTUHGAIN
DoorTypes Wood TIM Metal oireRm� 15 20 25 15 20 25 15 20 25��„`-",•':��•�';��"�- ,`�qna'��;fi�,x�$�,„�y
I
Single Pane g,g0 10.45 11.55 N 18 22 28 14 16 18 IS 12 13 12 264
Clea� 12 12$ NE&NW 37 41 45 31 33 35 26 27 28 0 0
WithStorm 4.75 5.25 6.50 e&w 52 56 60 44 45 46 38 39 40 0 0
DoublePane 5.51 6.09 7.25 sEasw 45 49 53 39 41 43 33 34 35 0 0
Clear 5 28 32 35 23 25 27 19 20 21 0 0
Withstorm 3.41 3.85 4.90 sMUann lbi 168 172 141 143 365 132136 140 0 0
TriplePane 4.39 5,46 wood-3 8.8 vos 131 8.6 109113 B.6 109 13] 0 0
qear 3.80 Me�al-Z 3.5 4.5 5.4 3.5 4.5 5.4 3S 4.5 5.4 0 0
lalousie 5 0 TOTALS 12 2�{
Single 1-For wood doors and
Sfngle w/Storm polystyrene wre metal doors
_ -
Skylights 11.07 11.69 12.92 2-For urethane core metal daors
Singie
oouble 6.65 7.35 8.75 TABLE D - INFILTRATION MULTIPLIERS
�oor7ypes 4� Winter Air Changes Per Haur
WoodOniy 0 0 FloorArea 90oorless 900-1500 1500-2100 ver2100
Woodw/Storm 3.2 Best 0.4 0.4 03 0.3
Urethane Care(R-5) 1.90 Aversge 1.2 1.0 0.8 0.7
Urethane Care 1�p Pwr 2.2 1.6 12 1.0
(R•5)w/Storm Fareachfireplaceadd: Best Average Paor
0.1 0.2 0.6
TOTALS
12 125
Summer Air Changes Per Hour
FloorArea 900orless 9m-1500 1500-2100 over2100
TABLE C -ADJUSTMENT FACfORS - (HEATING) e�c o.z o.2 o.z o.2
degFTemperatureDi(L 30 40 50 60 70 80 90 Average 0.5 0.5 0.4 0.4
AdjurtmentFactor 3 4 5 6 7 S 9 Poor 0.8 0.7 0.6 0.5
i
i a _� -�
� a3" x '
, _,
� Ex.st�,.t� Coao�t,oa�a SpA�
l � 6�(,sr,aG. �oo(L 'SO ��.m�,w1 ,
�EmodF Lw•sT�wl�`, �.._�.._...,...^.--_-_...__.�____�..� y .
`�
\
,uERHE'P� �°eR ? � �
1oTOQ. oQEA�MTOR � T�PICRL'� �tW 0`nL�TS \
�
�9.' n,G. ♦
.
i ' �
� `
�
�
' �ri�sT�r�C, 17f�`IWALI� FNSvLp7ED
� � �
NE�.� US�Naow TD � � �X�5tir1L CoNDiTieatC
W'P.L1.�j I
IY�RSCr1 kx,s,�r.!G � SPA a�., '
� � �
� _ �-
� �./�� EX�STi�JG, p0�w1Fl1.L� TIJS✓LM4T�EQ �
i � _ . ���f �
� Cm�! WALL _ _ _ _ _ ; ' C���,aas �o Q�mfl,nl
i/ �5 af9a¢. �FTo,�. ` , - - - ' Yt
.
�fCYjST L�NTiL D�i�. • i
iNDbW W I C�''�U SAtn85 �
r����D w� i2i6�d�CeNC, � i �
' �eW I +l a �vRM��, �- Fo�L ' .
� • 1�tILflT.aa� ��z'i �iNt�t) � ` .
�Stucco �a� pn,� • � " ��ywA,,v F�a�aid �
�L,�� ��` .
F�N�sa To n+s,e+� _ ��'I,�� e�
E��sr�N� , P��4'��5 � ,�
� � ,
� \
�� � - _ � G,c•sT�NS t��
\� .." � -
, b��ti`'�� a 3�- o � � 7o R�M�,�
5�� /� �
' yg��G 4 Cp��� I /" �
4
� G� �
��4y A�,� G p�' i . � � — R E+ho�E C�.�s T�a C,
R'''�G G� t t� N�w Cmu WA�I.,
��+ \v` i W I ik S 12E9A j� . ` I 3°� G�.8.� �ooR..
� \��,5 , �
��,�� ���j► /�'� � .
� �i�� � N�cW sTocc c �r� pa,�,- � ��
�G\�Q�"_,p����� I r�r�isN To MR���1 C��sna�
_\ � ��,�
, Q�
, �