HomeMy WebLinkAbout15-16342 ,/ r� CITY OF ZEPHYRHILLS f� 5335-8TH STREEI' / (sis)�so-oo20 16342 . BUILDING PERMIT SINGLE FAMILY RESIDENTIAL ' PERMIT INFORMA►TION LOCATION INFORMATION ' Permit#:16342 Issued: 6/05/2015 Address: 39317 AIR PARK RD Permit Type: GENERAL BUILDING PERMIT ZEPHYRHILLS, FL. Class of Work: ADD/ALT COMMERCIAL Township: Range: Proposed Use: NOT APPLICABLE � Lot(s): Block: Section: Sq. Feet: Est. Value: �� ��"' Book: Page: Cost: 3,820.00 Total Fees��, 82.50 Subdivision: CITY OF ZEPHYRHILLS Amount Paid: 82.50 Date Paid: 6/05/2015 Parcel Number: 13-26-21-0000-00100-0020 CONTRACTOR INFORMATION OWNER INFORMATION Name: SUN STATE ALUMINUM INC Name: CITY OF ZEPHYRHILLS Addr: 6154 FT KING RD Address: 39317 AIR PARK RD ZEPHYRHILLS, FL 33542 ZEPHYRHILLS, FL. 33542 Phone: (813)788-7308 Lic: RX0060171 Phone: Work Desc: INSTALL PAN ROOF 42 X 13 (AERO CENTER) �e- �r APPLICATION FEES BUILDING FEE 82.50 re� s �S � 2� �C S� � r� � Ins ections Re uired FOOTER 2ND ROUGH PLUMB MIS INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection trips are necessary due to any one of the following reasons: a)wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d)work not ready for inspection when called e) permit not posted on job site fl plans not at job site g)work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recoraiing your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be pertormed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. � CON RACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER ��`�'�`-�C,�,�1.�1� • a ��-�. ra 1'YJIiCHASE ORDER �'� : ,; ��;�. No. 0000026782 �i��� �f �ephyrhills ;:::��� �E. , °s V�NDOR: SIiIP'CO: BILLTO: Sun State Aluminum Inc City of Zephyrhills , 61541�ori TCing Rd 5335 8fh Si. Zephyrhills,i'L 33542 Zepiryrhills,FL 33542 > VE3VDOR NO. VGNDOTt PIiONE NUMBER ' TERMS DATE REQUIREU D�LIVERY DATE SunStAlu 0 0527RO i 5 S1iTPPII�G Y1�'STRUCTIONS ([wne) ITLM QTY U/Nf bFSCRIPTtON/TASIt PRD CODE ACCOUNT UIVIT PRIC� AMOUN'[' ] 1.00 Install Pan Roof aiid Repair old 042-4200-542-4600 3,82U.06 3,820.00 Gutters SUBTOTAL: 3,820.00 TAX: 0.00 SHIPPING: O.OQ TAXABLE: i`10 TOTAL: 3,820.00 CONFIRMING: �J�eG^ /. c.,��' L�—d`� L! AU'fT-IORIZED SIGNATUl2E IMPOl2TANT: OUR ORDER NUMBE[t MUST APYEAR ON EVL•RY lNVOlCEAND PACKAGL• Tl�is purcl�ase ordcr is givcn npon thc rcpresentalion and gunranty o}'the manuCacturcr ot scllc�hat no brcach of any Statc or 1'ederal Law or Rcguletion hes o�cu�red in connec�ion with tha manufacturing,processing,brznding,fabeling or l�ansporiation of Uu mercha�edise herain mentioned. If such 1�roacB oceurs or is chwgcd by any Iegally eons�iiutcd Sta�c or Federa!aut6oriry, ilre buyer shall be aitidcd to rescind��e order and retum the unused mercha�idise and sliall also bc I�eld harniless by�he menuCamurer or ullcr against any penelq�incurred ancllor the eosl of defense of any proueding designed to penTlize the huyer. o _ i �� I �LO'A�.w 11�fl�_ �.::- � . ' I� .. I City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: �� N ��Q��- /� t-V`'�� ''l�%'� Date Received: � - 2� - l � Site: � - - -� ��3 f� l�i�✓��1►�-2� � ,�J' , �� Permit Type: � �T�VI�(/�� 0 � Approved w/no comments Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. 7 • � �-a- l� I Kalvin Switz ans Examiner Date Contractor and/or Homeowner (Required when comments are present) �������� Page No. of Pages • ' SUN STATE ALUMINUM, INC. 6154 Fort King Rd. ZEPHYRHILLS, FL 33542 (813) 788-7308 SUBMITfED TO PHONE DATE G�' e,-° _ l3 1 STREET� JOB ME G�� CfTY,STATE end ZIP CODE JOB LOCATION ARCHITECT DATE OF PLANS JOB PHONE We hereby submit spec(ftcaUons and estimates for: � .._._.... � ���....�.`.�. 1..-{.. ...�.��C .._.�� ...�..-�... .� ._._. ���._. ... .. ... . .._.._. ._... ...._. ...._.__...._..........._. ._...C�-. ._. �`�� �� ._. ... ._....._._._... ...... ..._..... ._.. ._.._. ... ._. ._._.._.... ...._. ... ... ... .... _.._ ... ._.... ...... .. _...._._... ... ._.._._._..._. ._._.._. ._...... ...._. .._.._._.. ._..__.._. ... ._. ... .. ._._. .._. .. . ....._. . . . . ...___ . __._._. _. . _. .__....... ... ....... `�'._. C��-.Q.� ... ............. _.. .. ... .... _.... ... ... ... _�. ..... . .. .. ... _._.. , __._..._. ... .____......._._........... .___......_._. ._. ...._.... ._._._._._.... ... ._._._._. ._.. ._. .._._.._._._. ... ... ..__._....... ._. ........ ... �....� ._._.._....___........_.. . .._._._._..... ........ ._._.__.__. . . ..__. ._ ..._....._... ... ...... ._. ... , � ...._. .... ._. ... ... ._. ._. ._. ...... ....._... ...._.... .._.. ��.�.._... ... ...� ...._. ._. ... ..,�.�. �.--.�_. ...... __...._._.._..... ._._._.._..._. ... ._. ..... ... ._.. .-----. ... ... ...._. ._... ...... ._. ... ... .._. ..._. .._.._.... ... � __._. ._. ._..__._..._........ .._.... ._.. ...... ._...._... .._. .._........_. ...._...._......_. ... ..... ... .___..._. _._._. ._... ...._.._._._._._._--��v�-����...._._....... ._._..._. ._.__.._. ... ... .... ..._........ ... ...... ... ... ._. ... ._. ... ...... ... ... .._. ... ......_._._._. .............._.... ._._.... . ._. .. ......._....... .___. � _.__....... ...._. ._._.__.._.._..._.._.._.._._....... ._._. .........._.__.._._._....... ._.. .__. ._.._..-.---._._.__._._.._. ._._.__....._. ._._.. ._. ._..._.._... ._. .__..._._.._. ._.._._._._._.._.___..._._.. �C �DICtr�Ct hereby to furnish material and labor—complete in accordance with above specifications, for the sttu� of: `� l.f�� dollars($�J� ), Payment to be made as follows: All unpaid 6alances subject to 1.5%monthly interest fee. All material is guaranteed to be as specified.All work to be completed in a workmanlike manner according to standard practices.Any alteration or deviation from above specifications AUthOrized involving extra costs will be executed onty upon written orders,and will become an extra Signature charge over and above the estimate. All agreements contingent upon strikes, accidenLs or delays beyond our conhoi.Ow�er to rarty fire,tomado and other necessary insurance. Note:This pfoposal may be Our workers are fully covered by Workman's Compensation Insurance. withdrawn by us if not aCCepted within days. �LCCC�L�I�Ce Df �Cl�OYYLr�ICL—The above prices,specifications and conditions are satisfactory and are hereby accepted. You are authorized Signature to do the work as spec�ed. Payment will be made as outlined above. Date of Acceptance: Signature s�saso-oozo City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date 6teceived Phone ConQact for Permitting p�3 � -- 3 � � �Oe�rner's Mame B�" Z ` ( D CHc � y r � S Ovuner F'hone�dumber mvvner's�ddress V', ` � O�nmer 6'hone Rlumber �ee SiPnple Titleholder fdame Owner Phone Rlumber _t� �fLf Fee Simple Titleholder Address CA(��" .DO�41DDRESS J — �-�i!�S ��- ,33 J/�'— LOT# � SID�DINISIOkI ��1RCEL ID# (OBTAIfdED FROAA PROPERTY TAX PdOTICE) lfHORCC PROPOSED NEW CONSTR ADD/ALT � SIGPV Q � DEMOLISH B INSTALL B REPAIR �ROPO��D USE Q SFR Q COMM 0 OTHER T1f�E OF COfdSTRUCTIOf� Q BLOCK � - FRAME � STEEL 0 ID�SCRIPTIOId OE Hl/ORK �fa x /3 �UI�.DIMG SIZE �o�, �C 3 SQ FOOT�►GE �Ll�p F9EIGHY OBUILDING $ VALUATION OF TOTAL CONSTRUCTION ao. QELECTRICAL $ AMP SERVICE � PROGRESS EiVERGY Q W.R.E.C. OPLUMBING $ ���2 d� ,3 �-�—P(�,,. QMECHAfVICAL $ VALUATION OF MECHANICAL INSTALLATIOIV � , ���� r �GAS Q ROOFING Q SPECIALTY 0 OTHER 3 �� FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA �YES NO i` �,� Q���/�c�:�jy�i �_q � ,.� � �UILDER ���'S'� COAAPAIdY SG/i�,�S L`���'t'�� SIGWATURE REGISTERED Y/ I� FEE CURRE� Y/M 41t9dress License# � �b�c D �7 � �L�CTRICI�1fd COIIflPAWY S9GM�4TURE REGISTERED Y/ N FEE CURRE� Y/N �lddress License# ��lDRfiBE02 COAAP�4R9V 51G�Ut�Tl1PZE REGISTERED Y/ N FEE CURRE� Y/M e4ddress License# f1tI�CHAMICAL COiYiPAf�Y SIGRIATUltE REGISTERED Y I N FEE CURRE� Y/f� �►ddress License# OTHE6t COMPA,fdY SIG(dATURE REGISTERED Y/ N FEE CURRE� Y/M �dcdress License# R�SIDE(dTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Siit Fence installed, Sanitary Facilities 8 1 dumpster;Site Work Permit for subdivfsions/large projects CORAAAERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. I Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, i Sanitary Faciflties&1 dumpster.Site Work Permlt for all new projects.All commercial requirements must meet compliance S9Gfd PERAIIIT Attach(2)sets of Engineered Plans. °"'PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner 8 Contractor sign back of application,nota�(zed If over$2900,a fdotice of CoQnmencerv�ent is required. (?91C upgrades oeer$7500) •° Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same ONER YHE COUtdTER PERMIITTIR7G (Front of Application Only) Reroofs if shingles Sewers Service Upgrades A/C Fences(PIoUSurvey/Footage) Drivearays-Not over Counter if on`putilic roadwaqs.:needs ROW � , ' �� � � ` � J � . ; _ , , �: ,.. ., � . P10'TiCE Of� �EED ����'�OCYOOR��: The undersigned understands that this permit may be subject to"deed" restrictions" vvhich may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. lDP9LIC�NSED COB�7�ACYOR� �R9f� COR9Y�1���� ���P�O��86�ILIYGL��: If the ovvner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance writh state and local regulations. If the contractor is not licensed as required by law, both the ovuner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended confractor are uncertain as 4o what licensing requirements may appty for fihe intended work, they are advised to contact the Pasco County �uilding Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for vuhich 4hey �nrill be responsible. If you, as the owner sign as the contractor, that may be an indication that he is nof properly licensed and is not entitled to permitting privileges in Pasco County. '��f��PO�Y'�TIOR9 Ofi�l��C'�lU�'ILB'�If�� ���/��'�'�f�� ���OU�Cf� ��COi/��lf����: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion ofi existing buildings, as specified in �asco County Ordinance number 89-07' and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final pouver release. If the project does not involve a certificate of occupancy or final power release, fhe fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. C0�9S7�d�C710�9 L.OI�R9 L.�►@�(Cha�4�r 7�93, IFlc�rri����a���uQ��, �� �e���e���): If valuation of work is $2,500.00 or more, I certify that I, the applicanf, have been provided with a copy of the "Florida Construction Lien Law—HomeovNner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. COGdT42k�CYOF�'S101iN�1��'S �►��I�k�VI�': I certify that all the information in this application is accurate and that all work yvill be done in compliance with all applicable lavus regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be perforrried to meet standards of all laws regulating consfruction, County and City codes, zoning regulations, and land development regulations in fhe jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify v�rhaf actions I must take fo be in compliance. Such agencies include buf are not limited to: - Department of Environmental protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, lnlaterNVasteuvater Treatmenf. - Southwest Florida Water Nlanagement District-Wells, Cypress �ayheads, V1letland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Watenrvays. - Department of Health � Rehabilitative Services/Environmental Health Unit-VNells, VVastewater Treatment, Septic Tanks. - - US Environmen4al Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the�ollowing restrictions apply to the use of fill:� - Use of fill is not allowed in Flood Zone"V" unless expressly permitfed. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting vvhich is prepared by a professional engineer licensed by the Stafe of Florida. - If the fill material is to be used in Flood Zone "A" in connecfion �nrith a permifted building using stem vvall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill maferial is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions.of the building permit issued under the attached permit application, for lofs less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the ACI�RIT ��R TC�� Olf�9�f�7�, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. 0 understand fhat a separate permit may be required for electrical vuork, plumbing, signs, vvells, pools, air conditioning, gas, or other installations nol specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. �, �ild�RAll�d� T'O Ol�IRlIEf�: YOl1� ��+ILl1�� �f0 �Y����D � YV�YIC� Of� C�M�fiEYVCE�ifl�NIT i�i�V �f�SIDLT I�I YOtJR ��VIfV� �fiIIGE �O� Il�if�@ZO!/f�i�il�Yl9�� �'O Y0991F� ��OV�E��. IF YOU &�BVfEYVID TO O�Y�lIFI �IPIP►iVC0F1G, C�R9�111L� � Vil17H Y�ll� L�fd��cR O�Z�i�c�YYO(FtN1�Y�f��O�l� �Y��C��I�IR9G lf(D�1�3 R90�ICf�Of� CONiiiii�f�V�CIEYY�VdI�P1Y. FLORIDA JURAT(F.S. 117.03) OIfiINE�t OR AGEWT � COW7'�tACYOR��� � Su scribed and sworn o;(�r ffrmed before me this Subsp ribed and sworn to(or �rmed)before me this 29/iS by �i��U l'yl i rt?S s!�9lrS by ��r-�h.� {Nl► m S Who is/are personally known t _or has/have oroduced Who Is/are personallv known to me o has/have produced as identification. as identification. Notary Public Notary Public Commission No. �Ur g 3 L 9°1 Commission No. b�i'3�� Qi iJ0 E510-86E(LUt•)� .,,""""„ �e woo•aoiNag/ue3oNep, 1� „ :�04�YPUel�'; /VANCY J �ROOKS ��i„ ng�agp :a�. "'a.'� fVame of �Fe e�i pl��Al�(�#FF093699 Name o(Not ���t :,o: s 669£60��#NOISSIWWO�i1W i. �r•, 4 � . ;NA.. Qf 2. �••.",2�`••-�-oP�� EXPIRES February 18.2018 .�, � ',O� y0, j .,OFF��.r: s�ooae rA�rvdN --...Bna�d'°,,.;' (407)398-0153 FloridallotaryService.com General Ledger �Y��{�rr'a`n��.,, ,:;v,,�- " - Journal Entry Proof List � ��y ¢��� ,�.;�;;� ..t�rtu�wii`� k,�,B; User• ���� �� ��v���r��I��i � +�i'�r�k�;:��� - s�oppell �;� �i�:,�„� -,.. �. Printed: 6/3/2015-12:31 PM �w"�`'�� . ��. Batch: 00008.06.2015-enterprise permit fee Account Number Account Description Debit Amount Credit Amount Line Description System Reference Project Management Journal Entry:040-09-2015 Journal Entry Date:06/03/2015 001-0000-133-1000 Due Fr Pc General 157.50 0.00 entecprise pertnit fee _ 001-0000-322-0000 Building Permits 0.00 157.50 enterprise permit fee 002-0000-231-6850 Due To Anport Fund 157.50 0.00 enterprise permit fee 002-0000-231-1000 Due To General Fund 0.00 157.50 enterprise permit fee 042-4200-542-4600 Repair&Maint-Buildings 157.50 0.00 enterprise pemut fee 042-0000-133-1000 Due Fr Pc Airport 0.00 157.50 enterprise permit fee Joumal Entry Totals 472.50 472.50 Journal Entry Balance 0.00 Report Totals: 472.50 472.50 0.00 GL-Joi:znal Entry Proof List(6/3/2015-12:31 Pl� Page 1 I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN COMPLIANCE WITH ASCE7-10, &FBC 2010 WITH 2013 SUPPLEMENT. EXISTING HOST STRUCTURE 3"X12"RISER PAN PANEL BREAK FORM HEADER OR WHERE ATTACHING TO ECEIVING CHANNEL USE(1)#10 X 3/4"SMS /1-1/4"NEOPRENE WASHER / 2'FORM EDGE&@ 3"O.C.PER 3"X 48"X0.024"llb. / 'ii PANEL FOAM DENSITY #10 SMS AT EACH RISER COMPOSITE ROOF #10 X 4"SMS 1-1/4" PANEL FOR PAN OR#10 SMS @ NEOPRENE WASHER 8"O.C.FOR COMPOSITE PANEL 8"O.C.PER PANEL SOLID ROOF - - - PROFESSIONAL ENGINEER SEAL ENGINEER OF RECORD David W. Smith P.E. (3)3/8" FLORIDA LICENSE NUMBER:53608 THRU BOLTS WASHERS/NUTS 1-1/4 #10 SMS @ 8"O.C. Thomas L. Hanson P.E. (MIN) FOR COMPOSITE PANEL MAYNOTCH FORCENTER 2"X6"SMB BEAM(SEE FLORIDA LICENSE NUMBER:38654 OR EDGE OF POST (2)#10 SCREWS PER 12" SHEET S-2 FOR SIZE) WIDTH CONNECTING LI PAN TO HEADER(BOTTOM POST OR UPRIGHT Mark Ronald Dunn, Jr. OR BACK OF PAN) UPRIGHT(SEE P.E. SHEET S-2 FOR SIZE) 2)#10X2"SCREWS PER 12"WIDTH CONNECTING FLORIDA LICENSE NUMBER:73968 HEADER OR CHANNEL TO FASCIA. E Joel Falardeau P.E. EEII1S1 ROOF PANEL TO FASCIA CONNECTION DETAILS FLORIDA LICENSE NUMBER:70667 I SCALE:NTS (1)-1/2"0 LDT CONCRETE FBC Plans &Engineering SCREW WITH 2-3/4" NOTE:MINIMUM EMBEDMENT OF Services, Inc. EMBEDMENT(MIN EDGE ANCHORS INTO CONCRETE FOOTING SHALL 6272 Abbott Station Drive Unit 101 DISTANCE 3")FLANGE 08 2-3/4"AT ALL POST LOCATIONS.ALL Zephyrhills,fl.33542 SCREW LENGTHS AT POST CONNECTIONS Phone:(813)788-5314 — — SHALL BE OF SUFFICIENT LENGTH FOR Fax:1-(866)-824-7894 REQUIRED EMBEDMENT INTO CONCRETE Email:erb@Ibcplans.com PER OUTER FOOTING WHEN A PAVER DECK IS PRESENT. 1"PER FT.MAX FOR 2'-0" �Typ Website:www.fbcplans.com MIN BEFORE STEEPER C.O.A.-#29054290S4 SLOPE (2)-3/8"0 MACHINE BOLTS WITH WASHERS TOP VIEW OR(4)#14X 3/4"SMS ALUM.SQUARE COLUMN DRAWN BY: EA.SIDE 2"x2"x 0.125"ANGLE EXTERNAL REVISION: DATE: OR EQUIVALENT POST BASE (1)-1/20 LDT CONCRETE TYPE! . RO 1 SCREW WITH 2-3/4" FLAT SLOPE NO FTG oZ¢ EMBEDMENT(MIN EDGE OPT#2: FOR INTERNAL FASTENING RO 2 <2:12 d G� DISTANCE=3") (4)-3/8" 0 CONCRETE PER OUTER FLANGE SCREW WITH 2-3/4" RO 3 NOTES FOR ALL FOUNDATION TYPES EMBEDMENT(MIN EDGE DISTANCE=3" RO 4 1.THE FOUNDATIONS SHOWN ARE BASED ON A MINIMUM SOIL a MIN SPACING 2") BEARING PRESSURE OF 1,500 PSF.THE BEARING CAPACITY OF THE SOIL VERIFIED BY A LICENSED CONTRACTOR PRIOR TO ANY POURING c ° - OF CONCRETE. ° ° PROJECT ADDRESS: 2.THE SLAB/FOUNDATION MUST BE CLEARED OF ALL DEBRIS,AND 4 °_ -- -j COMPACTED PRIOR TO POURING OF ANY CONCRETE. d o a CITY OF ZEPHYRHILLS-FBD BLD. 3.CONCRETE MEET THE SPECIFICATIONS IN THE S-1 NOTES PAGE. 39450 SOUTH AVE K FRONT VIEW ZEPHYRHILLS,FL. TYPE II MONOLITHIC SLAB/FOOTING SCALE:N.T.S. G1 POST CONNECTION DETAIL S-4 SCALE:NTS CONTRACTOR: SUNSTATE ALUMINUM DETAILS S- 3 I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN COMPLIANCE WITH ASCE7-10, &FBC 2010 WITH 2013 SUPPLEMENT. PROFESSIONAL ENGINEER SEAL 3" X .024 PAN ROOF EXIST. ROOF ENGINEER OF RECORD FL 1779 OR EQUAL David W. Smith P.E. FLORIDA LICENSE NUMBER:53608 LI Thomas L. Hanson P.E. 1 r FLORIDA LICENSE NUMBER:38654 0 3" X 3" X 093 Mark Ronald Dunn, Jr..POSTS. TYP. P.E. OF 7 FLORIDA LICENSE NUMBER:73968 II Joel Falardeau P.E. FLORIDA LICENSE NUMBER:70667 EXISTING CONC. SLAB FBC Plans&Engineering Services,Inc. 5 r 6272 Abbott Station Drive Unit 101 J Zephyrhills,fl.33542 Phone:(813)788-5314 Fax:1-(866)-824-7894 Email:erb@fbcplans.com Website:wtvw.tbcplans.com C.O.A.-#29054 DRAWN BY: REVISION: DATE: SIDE ELEVATION RO1 3/16-"=1'-0" RO 2 RO3 RO 4' PROJECT ADDRESS: CITY OF ZEPHYRHILLS-FBD BLD. 39450 SOUTH AVE ZEPHYRHILLS,FL. CONTRACTOR: SUNSTATE ALUMINUM DETAILS S- 2C I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN COMPLIANCE WITH ASCE7-10, &FBC 2010 WITH 2013 SUPPLEMENT_ _ _ _ _ _ C _ 3" X .024 PAN ROOF PROFESSIONAL ENGINEER SEAL FL 1779 OR EQUAL ENGINEER OF RECORD David W. Smith P.E. FLORIDA LICENSE NUMBER:53608 I1� 2X6 SMB 2X6 SMB 2X6 SMB 2X6 SMB 2X6 SMB 2X6 SMB E Thomas L..Hanson P.E. 3" X 3" X .093 _ FLORIDA LICENSE NUMBER:38654 POSTS. TYP. OF 7 ! Mark Ronald Dunn, Jr. P.E. FLORIDA LICENSE NUMBER:73968 Joel Falardeau P.E. EXISTING CONC. SLAB FLORIDA LICENSE NUMBER:70667 9'-411 91-411 91-411 FBC Plans &Engineering a� Services,Inc. 6272 Abbott Station Drive Unit 101 Zephyrhills,H.33542 56' Phone:(813)788-5314 Fax:1-(866)-824-7894 Email:erb@fbcplans.com Website:www.fbcplans.com C.O.A.-#29054 FRONT ELEVATION DRAWN BY: 3116"=1'-0" REVISION: DATE: RO 1 RO 2 RO 3 RO4' PROJECT ADDRESS: CITY OF ZEPHYRHILLS-FBD BLD. 39450 SOUTH AVE ZEPHYRHILLS,FL. CONTRACTOR: SUNSTATE ALUMINUM DETAILS S- 2B / .: I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN COMPLIANCE WITH ASCE7-10, &FBC 2010 WITH 2013 SUPPLEMENT. EXISTING FBO BLDG. PROFESSIONAL ENGINEER SEAL NGINEER OF RECORD David W. Smith P.E. FLORIDA LICENSE NUMBER:53608 EXIST. CONC. SLAB 3" X 3" X .093 POSTS TYP. OF 7 _ Thomas L. Hanson P.E. FLORIDA LICENSE NUMBER:38654 2X6 SMB 2X6 SMB 2X6 SMB 2X6 SMB 2X6 SMB 2X6 SMB Mark Ronald Dunn, jr. P.E. g'_4" 9._4.. 9,-4„ 9,-4„ 9'-4" -i' 7 FLORIDA LICENSE NUMBER:73968 Joel Falardeau P.E. 56' FLORIDA LICENSE NUMBER:70667 FBC Plans&Engineering \3" X .024 PAN ROOF Services;Inc. FL 1779 OR EQUAL 6272 Abbott Station Drive Unit 101 Zephyrhills,fl.33542 7894 P L/\ N ` /I E /\' Fax:1-866)-824-7394 HIV V V V Fax:Email:erb@fbcplans.com ns.c erb@fbcplans.com 3/16" 1 1—0,1 Website:www.fbcplans.com C.O.A.-#29054 DRAWN BY: REVISION: DATE: RO 1 RO 2 RO 3 RO4• PROJECT ADDRESS: CITY OF ZEPHYRHILLS-FBD BLD. 39450 SOUTH AVE ZEPHYRHILLS,FL. CONTRACTOR: SUNSTATE ALUMINUM FLOOR PLAN S- 2 General Notes I HEREBY CERTIFY THAT I HAVE REVIEWED A:CONCRETE&FOUNDATION DESIGN: HOT DIPPED GALVANIZED. THIS PLAN AND FOUND EI 7-1T BE F N 1. ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 5.ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X 4. DOOR LOCATIONS MAYBE DETERMINED IN THE FIELD BY WITH 2013 1 SUPPLEMENT. 10, E FBC 2010 PSI MINIMUM. BOLT DIAMETER INTO STRUCTURAL FRAMING(G=.42 MIN.). CONTRACTOR. 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI 6.LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE S.IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL MINIMUM,3 1/2"NOMINAL THICKNESS. PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, 3. MINIM FIBERMESH(3/4"PER CUBIC YARD MIN.)MEETING GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF ENSURE BONDING AGENT IS USED FIRST. APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED THE BOLT OR SCREW.ALL LAG BOLTS AND SCREWS SHALL BE 6. SCREENING MATERIAL SHALL BE 18X14X0.013 OR oK IN LIEU OF WELDED WIRE MESH INSERTED IN PILOT HOLES BY TURNING AND UNDER NO EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED 4. ALL SLABS ON GRADE SHALL BE 4"THICK WITH FIBERMESH. CIRCUMSTANCES BY DRIVING WITH A HAMMER. ON DRAWING S-2. ALL L REINFORCING SHALL CONFORM TO ASTM A615,BE GRADE 7•ALL EXPANSION ANCHORS SHALL BE DESIGNED IN 7. 1"X2"X.045 NON-STRUCTURAL MEMBERS SHALL BE ATTACHED 60(60 KSI MIN.)DEFORMED BARS,#3 BARS MAY BE GRADE 40 ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S TO HOST WITH 1/4"DIAMETER X 1-3/4"EMBEDMENT&24"O.C. 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY MASONRY SCREW FOR CONCRETE&EQUIVALENT SIZE WOOD SCREW BE 3000 PSI MIN.,2"MINIMUM.THICKNESS. BE APPLIED IN CONDITIONS ACCEPTABLE TO WHEN IN WOOD&#10 X 1/2"EMBEDMENT SMS OR TEK SCREWS 7. SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF. MANUFACTURER FASTENERS SHALL BE A MINIMUM OF SAE IN ALUMINUM MEMBERS TYPICAL 7 / 8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE GRADE#5 OR BETTER ZINC PLATED. FOLLOWING: B.ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR OPC(PORTLAND CEMENT TYPE I,-ASTM C 150). PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 AGGREGATES-#6 STONE,ASTM C 33 SIZE NO.67 LESS THAN 18-8,UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES JOB DESCRIPTION: PATIO COVER FOR USE WITH ACQ PRESSURE TREATED WOOD,OR 3/4". OTHERWISE NOTED ON PLANS. PROFESSIONAL ENGINEER SEAL AIR ENTRAINING+/-1%-ASTM C 260. 9.ALL FASTENERS SHALL COMPLY WITH ASTM A153. WATER REDUCING AGENT-ASTM C 494. 10.ALL CONNECTORS SHALL COMPLY WITH ASTM A653 CLASS DESIGN DATA: OTHER ADMIXTURES SHALL NOT BE PERMITTED. FENGINEER OF RECORD CLEAN POTABLE WATER 1. ULTIMATE DESIGN WIND SPEED Vult,(3 SECOND GUST): 140 MPH 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. 11.FOR SMS,THE MINIMUM CENTER-TO-CENTER SPACING SHALL NOMINAL DESIGN WIND SPEED Vasd: 110 MPH David W. Smith P.E. 10.PREPARE&PLACE CONCRETE ACCORDING TO AMERICAN BE 3/4"AND MINIMUM CENTER-TO-EDGE SHALL BE 1/2" 2. RISK CATEGORY : II FLORIDA LICENSE NUMBER:53608 CONCRETE INSTITUTE MANUAL STANDARD PRACTICE,PART 1, UNLESS NOTED OTHERWISE. 3. WIND EXPOSURE C 2,&3 ALONG WITH HOT WEATHER CONDITIONS 4. WIND LOADS: RECOMMENDATIONS. E.REFERENCE STANDARDS: SCREEN ROOF: N/A Thomas L. Hanson P.E. 11.IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, ASTM E 119 SCREEN WALLS: N/A FLORIDA LICENSE NUMBER:38654 CONCRETE SHALL BE A MINIMUM OF 4"IN THICKNESS, ASTM E 1300 SOLID ROOF(MWFRS): 32 PSF VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, ASCE 7-10 Mark Ronald Dunn, Jr. SPALLING OR OTHER DETERIORATION. AA ASM35,AND SPEC.FOR ALUMINUM PART 1-A,&1-B 5. FACTOR APPLIED TO SCREEN WIND LOADS FOR 18X14X0.013 ASTM C94 OR EQUIVALENT DENSITY SCREEN MESH: N/A P.E. B.MASONRY: ASTM C150 6. FACTOR APPLIED TO SCREEN WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 FLORIDA LICENSE NUMBER.73968 1.CONCRETE MASONRY UNITS(CMU)SHALL BE STANDARD ASTM C33 7. LIVE LOAD: HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON ASTM C260 300 lb.VERTICAL DOWNLOAD ON PRIMARY SCREEN ENCLOSURE MEMBERS. Joel Falardeau P.E. TYPE M OR S MORTAR ASTM C494 200 1b.VERTICAL DOWNLOAD ON SCREEN ENCLOSURE PURLINS. 2.ALL MORTAR SHALL BE OF TYPE M OR S. ASTM A615 ASTM A185 8. EXIST.4"CONCRETE SLAB,2500 PSI MIN.CONCRETE W/6"X6"-#10WWM FLORIDA LICENSE NUMBER:70667 3.ALL GROUT SHALL PSI MINIMUM AND HAVE FLORIDA BUILDING CODE 2010 (CHAPTERS 16,20 AND 23) OVER 6"MIL POLYFILM W/EDGES LAPPED 6"&TAPED,OVER CLEAN COMPACTED SOIL MAXIMUM COARSE AGGREGATE REGATE SIZE OF 3/8". W2013 SUPPLEMENTS. SHALL BE ADEQUATE TO RESIST THE UPLOADS FORTHE PROPOSED STRUCTURE. FBC Plans&Engineering 4.PROVIDE CLEAN-OUTS FOR REINFORCED CELLS CONTAINING / REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-O"IN 2005 ALUMINUM DESIGN MANUAL Services,Inc. N A HEIGHT. F.ABBREVIATIONS: 9. SCREEN ROOF TYPE:10. SOLID ROOF TYPE 3"X12"X.024 ALUM.RISER PAN ROOF FL 1779 OR EQUIV. 6272 Abbott Station Drive Unit 101 THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED Phone:hills,fl.33542 C.ALUMINUM' TO REPRESENT ALL THOSE USED ON THESE DRAWINGS,BUT ZephPhone:(813)788-5314 TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. 1-(866)-824-7894 1. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE Email:erb@lbcplans.com MINIMUM REQUIREMENTS OF 6005-T5 FOR ALLOY WITHA 1.TYP--TYPICAL ALUMINUM STRUCTURAL MEMBERS Fax:--e: 6)-824-7B94.thcplans.com MINIMUM THICKNESS OF 0.040"FOR SUPPORTING MEMBERS. 2.SIM--SIMILAR 2. WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF 3.UON--UNLESS OTHERWISE NOTED C.O.A.Websit-#29054 0.024"SHALL APPLY. 4.CONT--CONTINUOUS HOLLOW SECTIONS 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO"PART 1-A- 5.VIF--VERIFY IN FIELD 2 x 2:---------------------------------------2"x 2"x 0.046" DATE: 05-28-2015 SPECIFICATIONS FOR ALUMINUM STRUCTURES-ALLOWABLE G.RESPONSIBILITY: 3 x 2:----------------------------------------3"x 2"x 0.050" STRESS DESIGN"OR"PART 1-B-SPECIFICATIONS FOR 2 x 3:---------------------------------------2"X 3"x 0.050" DRAWN BY: ALUMINUM STRUCTURES-BUILDING LOAD AND RESISTANCE 1.ALL SITE WORK SHALL BE PERFORMED BYA LICENSED FACTOR DESIGN"OF THE ALUMINUM DESIGN MANUAL 2005 CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING 2 x 3:---------------------------------------2"x 3"x 0.070" PREPARED BY THE ALUMINUM ASSOCIATION, CODES,LOCAL ORDINANCES,ETC. 2 x 4:---------------------------------------2"x 4"x 0.050" REVISION: DATE: 2.CONTRACTOR SHALL VERIFYALL DIMENSIONS AND DETAILS, 2 x 5: -------------------------------2"x 5"x 0.050" BI iI - r INC.WASHINGTON D.C.THE 2010 FLORIDA BUILDING CODE -------- T S}1 '_: (31y�LY WITS RO 1 NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEENA I .WITH 2009 SUPPLEMENTS(CHAPTER 16 STRUCTURAL DESIGN DRAWINGS,FABRICATED ITEMS,OR ACTUAL FIELD - rLOING RO 2 &HERE ALUMINUM 20 ALUMINUM).CME 3.THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 1 x 2:----------------------------------------1"ONS. OPEN BACK SECTIONS 2"x 0.040" LE CAL rL;' `BAG RO 3 4. WHERE COMES INTO CONTACT WITH STEEL,OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC 'SUNROOM'ROOM ADDITION ELEMENTS AS PROVIDED BY THE dL, ,tiP> F ' �'t}ral1s SEPARATION. 1 x 3:----------------------------------------1"x 3"x 0.045., 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS CONTRACTOR RO 4 THAN#10 SMS 6"FROM THE ENDS AND 12"ON CENTER,IF 4.ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND SNAP SECTIONS USING#12 SPACING MAY BE 24"ON CENTER. MANUFACTURER. 2 x 2 Snap:----------------------------------2"x 2"x 0.045" PROJECT ADDRESS: 6. VINYL/ACRYLIC/GLASS PANELS SHALL BE REMOVABLE.THEY 5.ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BYA 2 x 3 Snap: 2"x 3"x 0.050" SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING ---- j- CITY OF ZEPHYRHILLS-FBD BLD. "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND LICENSED P.E.IN ACCORDANCE WITH STANDARD 2 x 4 Snap:---------------------------------2"x 4"x 0.045" RE V a �; ( SPEEDS EXCEED 75 MEH".DECAL SHALL BE PLACED SO IT IS ENGINEERING PRACTICES. ,TE tp ' 39450 SOUTH AVE VISIBLE WHEN PANEL IS INSTALLED. SELF MATING (SMB) CI Ty T OF ZED. / J ZEPHYRHILLS,FL. (ACRYLIC/GLASS WINDBREAKERS INCLUDED) H.MISCELLANEOUS: ` HILL_g 1.ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A 2 x 4 SMB:---------------------- 2"x 4"x 0.044"x 0.100" LANS D.FASTENERS: MANUFACTURED HOME,TRAILER HOME,OR PRE-FAB HOME.IF 2 x 5 SMB:---------------------- 2"x 5"x 0.050"x 0.118" EXAM! /CS 1. ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE THE EXISTING STRUCTURE IS ONE OF THESE,A SEPARATE 4TH 2 x 6 SMB:---------------------- 2"x 6"x 0.050"x 0.120" 300 18-8,WITH STANDARD FLAT WASHER UNLESS WALL SUPPORT SYSTEM MUST BE ENGINEERED SO THAT NO 2 x 7 SMB:---------------------- 2"x 7"x 0.057"x 0.120" CONTRACTOR: MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED 2 x 8 SMB:---------------------- 2"x 8"x 0.072"x 0.224" WITH AC PRESSURE TREATED WOOD. HOME. SUNSTATE ALUMINUM Q2 x 9 SMB:---------------------- 2"x 9"x 0.072"x 0.224" 2.HEX BOLTS HAS TO BE ASTM A 325,PLATED WITH STANDARD 2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA,THE FLAT WASHERS AND NUTS. ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING 2 x 10 SMB:------------------- 2"x 10"x 0.092"x 0.374" 3.ALL CONCRETE SCREWS SHALL BE,SIMPSON,HILTI,RAWL, BARRIER REQUIREMENTS OF THE FLORIDA BUILDING CODE NOTES TAPCON,REDHEAD,DYNABOLT,OR APPROVED EQUAL. R 4101.17 IN ITS ENTIRETY. N 4.ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE 3• EMERGENCY ESCAPE&RESCUE OPENING PER FBC R310.1S - 1 SHALL BE VERIFIED BY CONTRACTOR&BUILDING OFFICIAL