Loading...
HomeMy WebLinkAbout15-16055 1 CITY OF ZEPHYRHILLS 5335-8TH STREET , ; (sis)�so-oozo 16055 BUILDING PERMIT � PERMIT INFORMATION LOCATION INFORMATION Permit Number: 16055 Address: 4645 WISTERIA DR LOT 19 Permit Type: ADDITION/ALTERATION ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: WHISPERING OAKS Est. Value: Parcel Number: 15-26-21-0160-00000-0190 Improv. Cost: 1,200.00 OWNER INFORMATION Date Issued: 3/04/2015 Name: EDWARD C ROWELL Total Fees: 187.50 Address: 4645 WISTERIA DR Amount Paid: 187.50 ZEPHYRHILLS FL 33542 Date Paid: 3/04/2015 Phone: 813-764-3426 Work Desc: GARAGE ENCLOSURE FOR LIVABLE SPACE 252 SQ CONTRACTOR $ - � APPLICATION FEES M NER BUILDING FEE 67.50 E E TR CAL FEE 60.00 HOMEOWNER MECHANICAL FEE 60.00 HOMEOWNER i Ins ecfions Re uire FOOT R 2ND ROUGH PLUMB MISC I ULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. �, CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTlON FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c)when extra inspection trips are necessary due to any one of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site fl plans not at job site g)work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this properly that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your properly. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application. All work shall be pertormed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFO C.O. - RACTOR IGNATU PERMIT OFFI R PERMIT EXPIRES I 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - $ HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 1 FORMS � ' FLORIDA BUILDING CODE,ENERGY CONSERVATION FORM 402-2010 Residentiai Building Thermal Envelope Approach ALL CLIMATE ZONES Scope:Complianoe with Section 402 of the Aorida Building Cbd�En�gy Conse�vation,sh�l be danonstrated by the use of Form 402 for single and multiplefanily residences of three stories or less in haght,additions to existing residenti�bwldings,renovations to existing residential buildings,new heeting,000ling,and water heating systens in oastin buildings,as �plic�le To compiy,a building must me�or e�coaed all of the�ergy�ciency requiranents on Table 402A and�I applicable m�d�requiremait�n��lzed in T�le 4026 of this form.If a bwiding does not comply wnth this me4hod or Alternate Form 402,it mag still oomply under Se�tion 405 of theRor�da Buildi Cbd�EnPr9Y PROJECTNAME. ?�'+��� �i5'Fe�^r�Q` , UILDER: �_ __ (/��_l __________ _ AND ADDRESS: :��h?IP�I��� r� PERMI�ING n. I r I` —��1N��.-�—�1\:Y-W==- ) �OFFICE l��T� a� ��p Yl y�'/►I I�� �_---�`'-3�yz�----=--------------T--------------- ------ OWNER: !PERMIT NO ��� ;JURISDICTION NO ��� General Instructions 1 �w construction which incorporates any of thefoliowing features cannot comply using this mdhod:glass ar�s in excess of 20 t of conditioned floor a�,dectric resistance h�t and air h�dlers located in attics. Additions 5 600 sq.ft.,renovations and equi pment changeouts may comply by this meth with exceptions given. 2.RII in all the�plicablespa�of the"To Be InstallEd"column on Table407Awith the information requested.All"To Be Inst�led"values must be equal to or more�cient than the required leoels. 3.Complete page 1 based on the"To Be Installed"column information. 4.R�d the require�ts of Tabie 4026 and check mch box to indicateyour intent to comply with all applicable items. 5.R�rJ,sign and date the"Prepared By'oertification stffianent�the bottom of pa�e 1 The owner or own�s a3ent must�so sign and date the form. Please Print CK 1 New construction,addition,or existing building 1 /�}U �'��d � � 2. Single-family detached or multiple-family attached 2. �n ��. Q ����i � 3 If multiple-family—No of units covered by this submission 3. /V lA v ✓ 4. Is this a worst case? (yes/no) 4 �d �' 5 Conditioned floor area(sq ft.) 5 �`"�� � 6 Glass type and area: � a U-factor 6 a ��� � b.SHGC 6b e ZS c Gl�s area 6c. ��_sq ft. � 7 Percentage of glass to floor area 7 � % � 8 Floor type,area or perimeter,and insulation a.5lab-on-grade(R-value) 8a.R= � �� lin.ft. � b.Wood,raised(R-value) 8b R=� sq ft. c.Wood,common(R-value) 8c R= �/�� sq ft. d.Concrete,raised(R-value) 8d R=�� sq ft. e.Concre4e,common(R-value) 8e.R=� sq ft. 9. Wall type,area and insulation a.Exterior. 1. Masonry(Insulation R-value) ga_� R=�sjj��sq ft. '✓ 2. Woodframe(InsulationR-value) ga_2. R= sq ft. b.AdjacenC 1. Masonry(InsulationR-value) 9b-1. R= /�/� sq.ft. 2. Woodframe(InsulationR-value) 9b-2. R=� sq ft. 10. Ceiling type,area and insulation a.Underattic(InsulationR-value) 10a.R=�30 sq ft. �� �� b.Singleassembly(InsulationR-value) 10b R=� sq ft. 11 Air distribution system Duct insulation,location,Qn �, a.D uct location,insulation 11 a. R= �_ ��f G b.AHU location 11b.� IS�/✓!ro {���s/!� ,C '`� c.Qn,Testreportariached(<0.03;ya/no) 11c.Testreport tached? Yes o r✓ 12. Cooling system 12a.Type: (i�)T/��/ ���-sf�� � ��fP�M a.Type 12b.SEER/EER: � b.Efficiency � 13 Heating system: 13a.Type:,��� ����n y h{a��r���U a.Type 13b HSPF/COP/AFUE:�y�'� b.Efficiency � 14 HVAC sizing calculation attached 14 Yes �o 15 Hot water system io)�,� ����1� ,F�1 j,5 f�q y /,�, 15a.Type: �y � a.Type 15b EF ar/ /�' b.Efficiency I F�Eby certify thd ttre pl covaed by the dcvl�ion ae in compli th the Forida �Revie.v of plats ad s�cdims o�vaed by this ail�ion indrdes canplia�cewilh the Forida ��� I Er�agy Code.BeFore cons[rud' is cornpl ed, buildng wiil be inspected fw mmpliaxe in � amrdaxewithSection � r � . Pf7�AR�BY: �CCDECH-1qAL I ha�y ify tF�this building is in compliaxewith the Rorida Eiagy Code i �A�: �,,� ��.� 3����I" C 4 2010 FLORIDA BUILDING CODE—ENERGY CONSERVATION FORMS , TABLE402A BUILDiNG COPAPONEI�T PEAFOABAANCE CRITERIA INSTALLED VALUES: _ U-Factor<0.65 U-Factor= Wmdows(see Note 2): SHGC=0.30 SHGC= 96 0l CFA<=20% g6 01 CFA= S li hLS U-Factor<0.75 Doors:Exteriordoor U-Factor U-Factor<0.65 U-Factor= Floors: Slab-ont,�rade No requirement R-Value= pyer�mcondtioned see Note 3 A-13 Walls—EM.and A�.(see Note 3): Frame R-13 R-Value= Mass (see Note 3) Irderior ot wall: R-7_8 R-Value= Exterior of wall: R-6 A-Value= Ceilfn s see Notes 3&4 R�0 R-Value= T���� Reflectance , 025 Reflectans:e T A��� YeslNo Air disVibution system(see Note 4) DucNroAc&air handling unit Loratinn: Uncorxfi6oned space Not allowed Tes[report Attached7 Condrtioned space YeslNo Duct R-value R-vaiue?6 R-Value= Air leakage�n on<_0_03 Q�_ Air con '' see Nnte SEER=�3.0 SEER= Heating system Heat pump(see Note 5) Cooling: SEER=13.0 SEER= Heating: HSPF=7_7 HSPF= Gas fumace AFUE 78% AFUE= Oil tumace AFUE 78% Afl1E_ ElecVic res'stance:Not altowed(see Note 5) Water heatimJ system(storage lype) pecUic(see Nole 6): 40 gaL•EF=0.92 Gallons= I 50 gal:EF=O_9D EF= ^ Gas fired(see Note 7�: q0 gal:EF=0.59 Gallons= Othe��descn.be�. 50 gal:EF=0.58 EF= (1)Each componerrt present in ihe As Proposed home must meet or exceed each of the applicable perfortnance criferia in orderto compiy with this code using this method; othervvise Section 4D5 compfiance must be used. (2)�ndows and doors qual'rfying as glazedienestratian areas must comptywith both the maximum U-Fac[orand the ma�dmum SHGC(solarHeat Gain CoeHicient)criteria and have a ma�dmum total window area equal to or less than 20%ot the conditioned iloor area(CFA);othervvise Section 405 must be used tor compliance. Exceptinn: Additions of 60D square feet(56 rr�}or less may have a maximum glass to CFA of 50 percent (3)R-values are tor insulation material only as app6ed in accordance with manufacturers'iostaliation instructions.For mass walis,the interiof ot walP'requirement must be met except'rf at least 50°k of the R-6 insulation required for the"exterior oi wall°is installed exterior of,or integral to,the wall. (4)Du�ts&AHU instalied substantially leak free per Section 40322.1.Test by Class 1 BERS rater required. Exception:Ducts installed onto an exisGng air disiribution system as part of an addition or renovation;duct must be R-6 installed per Sec.503.272. (5)For all converttional unils wiih capacities greater than 30,OD0 Btu/hr. For other types of equipment,see Tables 503.23(1-8). Exception:The prohb"dion on efechic resistance heat does not apply to add�ions,renovations and new heating systems installed in existing buildings. (6)For other electric storage wlumes,minimum EF=0.97-(0.00132 x volume). (7)For other nawral gas storage wlumes,minimum EF=O.fi7-(0.0019 x wlume). TABLE 4026 MANDATORY REQUTAEMENTS C�PONENTS ' SECTION RE�UIHEMENTS CHECK To be cauthed,gasketed,wealhersUippetl or othenvi�sealed.Aecessed tighting IGrated as rt�eating ASTM E i Air leakage 402.4 283.Wmdows and doors=0.30 dMsq.ft Testing or visual inspection required.Fuepiarxs:gasketed doors& I outdoor oombustion air. � Ceilingslknee walfs 405.21 R-19 space pemtit6ng. I Programmabte ihermostat 403.�.1 Where forad-air fumace is primazy sys[em.programmable themwshaf is required. I Air distributlon system 4032 Ducxs in attics or on rools insutaled to R-8;other ducts R�.Ducis tested to Oq=0.03 by a Ciass 1 BERS rater. Heat trap required for verticai pipe risers.Compty with efficiencies in Table 403.4.32.Provide svitch or dearly � Water heaters 403.4 marked circuit breaker(elecVic)or shutoft (gas).Circulating system pipes insulated to=R-2+aa�ssible manual OFF switch. Spas and fieated pools musl have vapor-retatdant cavers ar a tiquid cover ar other means proven to reduce heat Swimming pool S spas 403.9 bss except it 70°h ai heat hom site-recovered energy.OtUtimer switch required.Gas heaters mirdmum thermal effiae =78% B2%afterM16H3.Heat um oolheatersminimumCOP=4.0. Smng calculation perfortned&attached.Minimum etficiencles per Tabies 50323.Equipmerrt efficiertcy verification Cooling/heating equipment 403.6 required.Special oxaston cooling or hea6ng capaciry requires separate system or variabie capacity system. Electric heai>�OkW must be divided iMO two or more sta es. Lighting equipmer�t 404_t At least 50%of pertnane�'ustalled IigMing fadures stpll be hi9h-efFuacy 1amAs. 2010 FLORIDA BUILDING CODE—E{1l5RGY COMSEFiVRTION C•� 1 vJ�S r Fyylilttl�il��u'-Y�' 1P�s7� r°?"';�;�Ma' '�;��,� '` '1�..+_�' _ ^k��.., .S.• City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: �pw�►AQ �\D w E�` Date Received: 2 — �� — � S Site: ��3 �� �A� ISTEQIA �Q.. PermitType: REa+IODEL. (1�A�LA�E -l�0 3�dileoNl Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ w' �� / �'- �'c � c: � .�e �� , �C ��l �lG� �f � ' —e'U� =�,��E 9� !�'� � C ��' (J ��c� d CU C = � � - -�C , , . . ' �fC _ �-./ 0 ' � �1�-Pb�� This comment sheet shall be kept with the permit and/or plans. ��,f _.... �IJ` Kalvin Switzer— Examiner Date Go tor and/or Homeowner (Required when comments are present) � 813-784-dd20 City of Zephyrhills Perrnit Appiication Fax-813-78d-0021 , Building Department ' bate Reaeived � Phone Contact for Permitting — Owner's Name � Wp✓ Owner Phone Number (`� 7�"� ��y�� Owner's Address L✓` "`�r'�I�,� '�' � Owner Phone Number �� � Fee Simpte Titlehoi er Name ��'�C'�'� ��,�_� Owner Phone Number � � Fee Simple Titleholder Address l�* n ��i �' ��ST �R i � �� JOB ADDitESS LOT# �� suso�v�sioN �- � � PARCEi.ID# ! 5 - 26 - Z,t - �t�,o _ o0000 - o�90 (OBTAINEp FROM PROPERTY TAX NQTICE) WORK PROPOSSD e NEW CONSTR 8 ADDIA�T � SIGN � Q DEMOI.ISH INSTALL REPAIR Pt20POSEQ USE Q SFR [� COM{iri � OTNER TYPE OF CONS7RUCTION Q BLOCK Q FRAME 0 STEEL Q DESCRIPTION OP WORK �`����Sti -���'li O � SUILDING SIZE �� � SQ FOOTAGE C�� HEIGHT �� � , �Bt11l.DING $ / -�x✓y� VALUATION OF TOTAL CONSTRUCTION � �ELECTRtCAt. � � AMP SERV[CE � PROGRESS ENERGY Q W.R.E.C. �PLUMBING �> � ����r� OMECNANtCA� $ VALUATION flF MEGHANtCA�lNSTA�LATIQN � QGAS Q RQQFING Q SPECIALTY � OTHER FINISHED FLOQR ELEVATIONS � � FLOOD ZONE AREA QYES NO BUI�DER '1 �^ �fCOMPAI+IY � �' t�+�4�'�/ �IGNATURE K� REGISTERED Y/ N FEE CURRE� Y/N Address License# � EI.ECTRICIAN � COMPAMY � SIGNA7URE REGISTERED Y/ N FEE CURRE� Y/N Address License# � � PI.UMBER CQMPANY SIGNATURE REGISTERED Y/ N FEE CUFtRE� Y/N Address License# �� � MECHATdICAL �'"'- _�-�"�'„�—�-7� • � �_ °�c--COMPANY SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Address License# �— � QTNER J � COMPANY SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N ,,....., �„_,,._,_ Address License# r� � RE3IDENTIAL AEtach{2}Plot Plans;{2}sets of Buitding Pians;(1}set af Energy Farms;R-O-W Permit#ar new construc#ian, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Santtary Facilities&1 dumpster;Stte Work Permit for subdlvisionsAarge projects COMMERCIPd. Attach{3}complete sets of Suitding P1ans plus a Life Safety Page;{1}set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)warking days after submittal date. Required onsite,Construcfion Plans,Stormwater Plans w/Silt Fence installed, - -- Sanitary Facilities&1 dumpster.Site Work Permit for aii new projects.A41 commerciai requirements must meet compl'sance 3IGN PERMtT Attach{2)sets of Engineered Ptans. ""PROPERTY SURVEY required far all NEW construction. Diractions: Fill aut application completely. Owner 8 Cantractor sign back of appi�cation,notarized tf aver$2500,a Notice of Commencement is required. (A/C upgrades over$7500) "* Agent(for the contractor)or Power of Rttamey{for the owner}would be someone with notarized istter from owner autharizing same OVER TNE COUNTER PERMITTiNG (Front of Applicatian Only) Reroofs if shingles Sewers Service Upgrades A/C Fences(PIoUSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to°deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND COP17R�►C70R RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance virith state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired.a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of�this�applicatidn`for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. YR�►NSPORTATION IMPACTIUTILITIES IIMPAC7'AND RESOURCE RECOVERY FEES: The undersigned understands that Transpb�tation Impact�Eees and Recou�se ftecovery:Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I '� certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owrner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be perFormed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. � I understand that the following restrictions apply to the use of fill:� - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone °A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the�►GEIVT FOR THE OVi1NER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plurnbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to.violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate I justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWiVER: YOUR �AILURE TO RECORD A NOTICE OF COMMENCEMENT IV1AY RESULT IN YOUR PAYIfVG TWICE FOR IIVIPROVENiENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, COFISULT I IiVITH YOUR LENDER OR AN�1TTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEf1AENT. '� FLORIDA JURAT(F.S. 117.03)- - _ _ ,_ _ _ �_ > OWINER OR AGENT CONTRACTOR Subscribed and swom to(or affirmed)before me this Subscrlbed and swom to(or affirmed)before me this by bY Who is/are personally known to me or has/have produced Who(s/are personally known to me or has/have produced as IdentlficaUon. as identificaGon. , Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped