HomeMy WebLinkAbout15-16482 i �
` .. CITY OF ZEPHYRHILLS �'r!
5335-8TH�STREET
(si3)�so-oozo 1 $2
BUILDING PERMIT
PERMIT INFORMATION LOCATION INFORMATION
Permit Number: 16482 ; Address: 38434 5TH AVE HISTORIC
Permit Type: MECHANICAL ZEPHYRHILLS, FL.
Class of Work: A/C CHANGEOUT Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Square Feet: Subdivision: CITY OF ZEPHYRHILLS
Est. Value: Parcel Number: 11-26-21-0010-16700-0055
Improv. Cost: 5,900.00 ; OWNER INFORMATION
Date Issued: 7/31/2015 . Name: MOSS S ARDELL
Total Fees: 65.00 Address: 38434 5TH AVE HISTORIC
Amount Paid: 65.00 ZEPHYRHILLS, FL. 33542
Date Paid: 7/31/2015 Phone:
Work Desc: A/C CHANGE OUT 3 TON SPLIT SYS�TEM
CONTRACTOR S E APPLICATION FEES
CGM SERVICE INC A/C CHANGE UT 65.00
. <��
, i 1 C
n ���
� v �
/
� Ins ectionsiRe uired
D CTS INSTALLED
DUCTSINSULATED
FINAL
REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection
I trips are necessary due to any one of the following reasons: a)wrong address b) condemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d) work not ready for
inspection when called e) permit not posted on job site t) plans not at job site g)work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and therelmay be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with
City Codes and Ordinances.NO OCCUPANCY BEFO C.O.
�
CONTRACTOR SIGNATU PERMIT OFFI R
PERMIT EXPI S IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD� FROM WEATHER
�
�
. � , I
SERVICES
AIR CONDITIONIN�G AND HEATING
July 29, 2015 �
I
�
C1TY OF ZEPHYRHILLS
� REFERENCE: CACO26444 (dba CGM Services, Inc.)
SUBJECT: AUTHORIZED SIGNER
To Whom It May Concern:
!, Michael G. Charles, hereby give my autho�ization for the following person listed below
to sign for all necessary paperwork for CGM�Services, Inc., for the purpose of obtaining
and/or picking up mechanical permits, with City of Zephyrhills.
Y� attention to thi atte ' greatly appreciated.
�
r. Michael G arles (CACO26444)
Ernest Guernsey (I to e shown upon request)
Before me personally appeared Mr. Michae�l G Charles to be person described in and
who executed the foregoing instrument and acknowledged to and before me that he/she
executed said instrument for the purpose herein expressed.
Witness: My hand and official seal this�_day of �V , 2015.
� (�1 ��'`i��`'OEBRA'��y'�';��:
�.....;,c� r,
Notary Public, State of Florida � r�G�gustg��'l'' ;`�y%
�*: � �' �g``��:
�Z i "'�9: �
.—�' �'_ 'Ti' �
�� bFF�� `n�*=
.°•�: J.B : 2
f•0 f�,c°��d thN I 'O��
�'iG6 °:;'�nsumnd°� �Q�`,��
fs'/,���se 1101�11+,O`,,�
1015 E. M.L. King Jr. Blvd., Tampa, Florida 33603
(813)AIR-COOL(247-2665)
Commercial & Residential FAX (813)i247-6535 IndoorAir Quality
I Sales &Service www.cgmservices.com Refrigeration
� � a�saso-oozo City of Zephyrhilis Permit Application Fax-813-780-0021
�' �,�;r Building DepaAment
�
' Date Received phone Contact for Pertnitting
-rIT�- --
Owners Name ///D�D.� S ����LL Owner Phone Number
Owners Address `y' �w � Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simple TiUeholder Address �
JOBADDRESS S � � UE � J LOT# �
I
SUBDIVISION PARCEL IDl� '
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED e NEW CoNSiR e ADD/ALT � SIGN 0 Q DEMOLISH
INSTALL REPAIR
PROPOSED USE Q SFR �� COMM Q OTHER
TYPE OF CONSTRUCTION Q BLOCK Q FRAME 0 STEEL Q
DESCRIPTION OF WORK G � � f l/"
BUILDING SIZE SQ FOOTAGE�� HEIGHT
TI"1'T' �T
QBUILDING $ VALUATION OFTOTAL CONSTRUCTION
�ELECTRICAL $ AMP SERVICE ' 0 PROGRESS ENERGY Q W.R.E.C.
OPLUMBING $ � I� �� Y
�MECHANICAL $ O, i VALUATION OF MECHANICAL INSTALLATION � �
� � �� �
QGAS Q ROOFING Q SPECIALTY 0 OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA �YES NO I
�-�--.�5-�' '.�.����::'-.-:-r��:+�.--•--.-i-��L.'� 'I' �.--•--.-.-�5-:�.�.�..r.�..-.�.-.-.�-r�.�.-r�
.+I
I
� BUILDER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address License#
ELECTRICIAN � COMPA IY � ���N�
SIGNATURE � REGISTERED Y/ N FEE CURREA Y/N
Address License#
PLUMBER COMPANY
i SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address License#
MECHANICAL COMPAI Y (o L7l�/ S�/(UI CLS
SIGNATURE REGISTERED Y N FEE CURRE� Y/N
i �/��
' Address � E O�U(.� /i"� License# /7L.(/
OTHER COMPANY
ISIGNATURE REGISTERED Y/ N FEE CURREA Y/N
Address License#
1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 I 1 I 1 1�1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Fortns;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Pians w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(3)complete sets of Building Pians plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permi[for new construction.
Minimum ten(10)working days aker submittal date. Required onsile,Construction Plans,Stortnwater Plans w/Silt Fence inslalled,
� Sanitary Facilities&1 dumpster.Site Work Pertnit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans. i
""PROPERTY SURVEY required for all NEW construction.�
..i-1..1..1-G�...r�l.-�1-.4�1.-�C�..r..�1-1�1.-FI-.4�1.-4�F-i-'.+�..+-1-�F' • .--r.--r�4�1.-4�5�.-.�
Directions:
Fill out applicaGon completely
Owner&ConVactor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades'over$7500)
" Agent(for the contractor)or Power of Attorney(for lhe owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (Front of Applicalion Only)
Reroofs if shingles Sewers Service Upgrades A/C Fences(PlotlSurvey/Footage)
Driveways-Not over Counler if on public roadways..needs ROW '
• } �- , �
. ' NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicabie deed restrictions. ,
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner�and contractor may be cited for a misdemeanor violation
' under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or;contractors, he is advised to have the contractor(s) sign
portions of the"contractor Block"of this application for whichithey will be responsible. If you, as the owner sign as the
contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands,thaY such fees, as may be due,will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or
final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County WateNSewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner',I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner"prior to commencement. i
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating�construction,zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is �
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands,Water/Wastewater Treatment. �
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls,Docks,Navigable Waterways.
- Department of Health & Rehabilitative Services%Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways. j
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone"V"unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume"will be submitted at time'of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone ";4" in connection with a permitted building using stem wall
construction,I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating
the conditions of the building permit issued under the attached permit application,for lots less than one(1)
acre which are elevated by fill,an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this a�davit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other,installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or
set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension
may be requested, in writing,from the Building Official for a�period not to exceed ninety(90)days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned.
WARNING TO OWNER: Y UR F ILURE T ECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMP VE NT T OUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER O AN N BEFORE RECORDING YOUR NOTICE F COMMENCEMENT.
FLORIDA JUR,4T(F.S.117.03 i
OWNER OR AGENT CONTRACTOR
Subscribed and sw t ed b fore this Sub's/ri ed and or to or f irme )before m his `
��.3�—�5 by VVI�I��by � $ U . 1
o is/are personally kno n to me or has/have produced i/are personally nown to me or has/ha produce
°f50 as identification. as' ntification.
! I
�� Nolary Public I ;� ' Notary Public
o \� �. • •., �/
' ' Commission No, y�.�\ Q,�phISS/ °��.,t/��
Y RODRIGUE ' o
�,o�►"'"�o`,� WEND � o �d'o v9uste,�o�-°.� �
a f`jycRar�p��g���k6 Name of Notar�y�ecg nted or stampec4 m Q �
'�t�'�' 2��s ° a aYO� Cn:�°
'+••�•••••-�� EXPIRES November i8, �z.
••.�'oFC.;,,.,•�' #�F02285,5 JQQ'�
(407)399-0153 FloridallotarySetvice.com ' ���:
�9• �onded lhN �Q��
%.�,��,p•o'�Yfdrn.lnsu2c�;. �,0��
--- , ////r���l11 u a i'i�NO��\\a\
�
July 25,2015 AIR CONDITIONING AND HEATING
Ernie Harrell
Cross Construction Company, Inc.
25221 Wesley Chapel Blvd. i
Lutz, FL 33559
Office 813 973-4191 Fax 813 948-6722 Email: cccamdawson(a�verizon.net
Subject: Downtown Visitors Center
38434 5`h Avenue
Zephyrhills,FL 33542
RE: AC Replacement Proposal
I
We are pleased to provide the following pricing and information for the installation of 3.0-ton split
system heat pump replacement in existing home, including the following:
Equipment Schedule: �
CARRIER Comfort 14 series 3.0-ton Air Conditioning Replacement-ARI Ref#7850599
Md#25ACC436A003 Condensing Unit �
Md#FB4CNF036T00 Indoor Air Handler Section
Md#CEOO1N08 5 KW heat assist
33,400 BTUH Cooling Capacity 14.00 SEER
Control: Venstar Digital Programmable Thermostat �
Warranty: 1-Year Labor, 5-Year Parts and Compressor
Scope of Work:
■ Remove and disposal of existing equipment
■ Provide and install new 3.0-ton system per equipment selection.
■ Provide and install new thermostat control per equipment selection.
■ Condensing unit to be relocated to grade level on new pre-caste concrete pad.
■ Provide and install new refrigerant piping with arrmaflex pipe insulation.
■ Provide and install new vertical mounted air handler(same as existing)with float protection and
condensate drain piping connection to existirig.
■ Provide and install new supply/return ductwork with start collar and mechanical fasteners.
Modifications of existing supply/return trunk to new supply/return plenum.
■ Connect and evacuate refrigerant piping.
■ Re-connect existing electrical hookups to new equipment. Check breaker sizes.
■ Start-up of equipment. i
■ All permits and inspections. i
Contract Amount$5,900.00 �
This proposal reflects materials,workmanship,and job response necessary
to assure a high standard of inech�anical installation for this project.
�
Ernest T Guernsey-Vice President
CGM Ser,vices, Inc.
7015 E Martin Luther King Blvd
Tampa,iFl 33603
Office 813 247-2665 Cell 813 422-1683 Fax 813 247-6535
Email etg(n�c�mservices.com
Website www.cEmservices.com
I