HomeMy WebLinkAbout16-17271 CITY OF ZEPHYRHILLS %'
5335-8TH STREET '�
(sis)�so-oozo 17271•�
FIRE SPRINKLER SYSTEM PERMIT �
PERMIT INFORMATION LOCATION INFORMATION
Permit Number: 17271 Address: 40119 CR 54
Permit Type: FIRE SPRINKLER SYSTEM ZEPHYRHILLS, FL.
� Class of Work: FIRE-SPRINKLER SYS Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Square Feet: Subdivision: CITY OF ZEPHYRHILLS
Est. Value: Parcel Number: 06-26-22-0000-01500-0020
Improv. Cost: 3,781.00 OWNER INFORMATION
' Date Issued: 5/17/2016 Name: STAHL FAMILY FARMS LLC
Total Fees: 175.00 Address: PO BOX 550
Amount Paid: 175.00 JANE LEW WV 26378-0550
Date Paid: 5/17/2016 Phone:
Work Desc: INSTALLATION FIRE SPRINKLER SYSTEM-VIKINGS POOL
'CONTRACTOR S APPLICATION FEES
C MERCIAL FIRE COMM CA N.. FIRE SPRINKLER SYS 50.00 FIRE PLAN REVIEW FEES 50.00
' FIRE INSPECTION FEES 45.00 CONTRACTOR CERTIFICATE 30.00
�
� �
�� '1i
� .
l Ct-G2_ t n � ��"c�..eP-
Ins ections Re uired -
FIRE-PRESSURE TEST -
FIRE ACCEPTANCE Final —.1���
Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire
prevention and protection related activities such as inspections, plan review,administrative fees,and other
costs related to the aforementioned.
Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of
the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final
inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All
work shall be pertormed in accordance with City Codes and Ordinances.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMEN ENT."
�
CON RACTOR SIGNATURE PERMIT OFFICE
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED �
ZEPHYRHILLS FIRE RESCUE DEPT- 813-780-0041
' o� '
�c:-'�� . - ~�..,;3k-
�;�,' �v,., �rt��
`.K'Lx--_ s�'� '-f"'�,
>.�.,�,-_.;.,��.�...si„"�%
�s�� `
�`
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner: �j�l'►'l��P.�2r� � �/ ����lcG2�1'�'1
�Z�
Date Received: _/f(7 'l .(�
Site:' • � d �� � �/� S�" - .
� /i /
Permit Type: ��`� �.�Y''� �1�C l�� V� �t nG ��6S
J
Approved w/no comments:l�' Approved w/the below comments: E�" Denied w/the below comments: ❑
:,—•
� C-s p-! �P�.�,^r-t ti�C7� i.��;� i. d... 'r.a c—`wan.) r�`c.. ��,a;L' ��.*�.c'�
�5"��C'� �r7►'�1v �d/�.r��r'$��S
This comment sheet shall be kept with the permit and/or plans.
�
. � �� / '
-.._�,•c- _�..� � iY /[o W
Gene Brown—Fire Safety Officer ate Contractor d/or Homeowner
(Required when comments are present)
ZE�!°�YRFIBLLS F�RE DEPe4R`fli�E�VI`
38410 6th Ave Zephyrhills, FL 33542
FIRE SERVICE USER FEES
Occupancy No.:
Plan No.: Contractor: C r C �'R�,�,��,.,� t,..�.• �'�,__
Business Name: \f,;� ,�,r� �vd/ � L C Billing Address: `�o �7 crx • �s'o
Business Address: �,r� j_+4 r'�2 :��I G n s� �n�c�,c Fi �3� �� q .. ,-3-�Q
Business Phone No.: �� ;�'�. ��,�� �. Billing Phone No.: •��"i�- S'�3 c,- �/�� �
Business Fax No.: ��3 ;b*� . ��� ��'/' Billing Fax No.: 7.� 'y �- �3.���Y�rv
Contact: ��a zlr��-r� c.-'s.�,r-�-s•- Contact:
PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE ALARM FEE
sitePlan N/C Annual N/C u' Sprinkler $50 1stAlarm N/C
Multi-Family/Commercial .06 sf 1st Re-inspection N/C Standpipes $50 2nd Alarm �N/C
(Minimum Charge$25.00 2nd Re-inspection $100 Fire Pump $50 3rd Alarm N/C
� �lan Revisions DBL 3rd Re-inspection $250 Hoods $50 4th Alarm $100
4th Re-Inspection $500 Fire Alarm $50 5th Alarm $150
SPRINKLER SYSTEMS (Business closed until LP Gas $50 6th Alarm $200
Jt 0-25 Heads $50 violations corrected) Natural Gas $50 NON COMPLIANCE $150
26 plus Heads $100 SPRINKLER SYSTEMS Fuel Tanks- pertank $50
STANDPIPE SYSTEM Hydro Undergrounds $45 Sparklers $100
� Per Riser $50 1-lydrostatic Test $65 per system Fire Works $500
FIRE PUMP AcceptanceTest $45 persystem Camp Fire $25 �
� Per Pump $100 Hydrant Flow $75 Controlled Bum $100
FIRE ALARM SYSTEM Hood/Duct $50
� 0-25 Devices $50 FIRE ALARM SYSTEM Place of Assembly $50 Mnual
26 plus Devices $100 System Acceptance $50 Fire Protection $25
SUPPRESSION SYSTEMS Recall Acceptance $50 Flammable Application $50 nnnua�
Wet $50 OTHER Waste Tire Storage $50 Mnual
Dry $50 Fire WalUSmoke Wall $15 Perwan Generator<KW $100
CO2 $50 LP Gas $25 pertank Generator>30 KW 150
Other $50 Natural Gas $25 persystem Bio-Hazard Waste $100 Annual
KITCHEN EXHAUST Fumigation Tenting $50
� Hood/Ducts $50 Tent 10'x10'or greater $15 per tent Torch Pot/Applied $50
OTHER Fire Pump $45 Haz.Materials $100 Mnual
�P Installation per tank $50 Fire Suppression $30
Fuel Tank Installation $50 System Acceptance
❑ (Per Tank) $50 � Exhaust Hood/Duct $30
Natural Gas Installation $50 Re-inspection DBL
(Per System) (other than annual)
� Spray Booth $50 � Inspection scheduled DBL �
and cancelled less than
24 hours
BConstruction Insp. N/C
Emergency Vehicle A� $50 FALSE ALARM
PLANS TOTAL 5:e: INSPECTION TOTAL� PERhflITTOTAL S(s TOTAL�
GRAND TOTAL
Comments:
C �st,+i 2/,1 .:�9�� � ��.� �� �r. �W �4 s..a.. `j.?"�rt! Y—��vQ.L•�
r���c-Fti i�,+�-7 s•:i.<+-.-�il•.�.-��r
r
Date: a i rYG
�-•>
Inspector: _ r- L.-..�. ,�----
nm
- NOTICE OF COMMENCEMENT
This Instrument Prepared By: I IIIII)IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIII IIII ! ;
Name Edrei Soto 2016071113
Address 6510B 125`h Ave.N. Lar�o,Fl.33773 , Rcpt:1769163 Ree: 10.00
Permit No. " • DS: 0.00 I T: 0.00 �
TaacFolioNo 06-26-22-0000-01500-0020 05/06/2016 S. 5. , Dpty Clerk I
THE LJNDERSIGNED hereby gives notice that improvements will be made to certain real properiy,and in accordance with Section
713 13 of the Florida Statutes,the following information is provided in this NOTICE OF COMM�NCEMENT.
1.Description of properiy(legal description): 40119 County Rd 54 Zephvrhills FL 33540 - 06-26-22-0000-01500-0020
2.General description of improvements: Fire Sprinkler Svstem Renovation.
3 Owner Information ----
a)Name and address: Stahl Familv Farms LLC - PO Box 550 Jane Lew,WV 26378
' b)Name and address of fee simple titleholder(if other than owner) : N/A
c)Interest in properiy N/A
4.Contractor Information
: a)Name and address: Sean R. Guthrie of Commercial Fire&Communications,Inc. 6510 125`h Ave N,Lar�o FL 33773
b)Telephone No.: 727-530-4521 Fax No. (Opt.) 727-531-0596
S.Surety Information
a)Name and address: N/A
b)Amount ofBond:
c)Telephone No.: % PRULA 5 0�NEIL,Ph D PASCO CLERK & COf�PTROLLEF
6.Lender 05 R6 B 16 11:41am 1 �,���
a)Name and address: N/A �3�� PG �7
Phone.No.
7.Identity of person within the State of Florida designated by owner upon whom notices or other documents may be served:
a)Name and address: Sean R Guthrie of Commercial Fire&Communications,Inc 6510 125`h Ave N,Lar�o FL 33773
b)Telephone No.: 727-530-4521 Fax No. (Opt.) 727-531-0596
8.In addition to himself,owner designates the following person to receive a copy of the Lienor's Notice as provided in Section
713 13(1)(b),Florida Statutes:
a)Name and address: Sean R Guthrie of Commercial Fire&Communications,Inc 6510_125`h Ave N,Largo FL 33773
�b)Telephone No.: 727-530-4521 Fax No. (Opt.) 727-531-0596
9.Expiration date of Notice of Commencement(the expiration date is one year from the date of recording unless a different date
is specified):
WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF �
COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDEYt CHAPTER 713,PART I,SECTION 713.13,
FLORIDA STATLTTES,AND CAN RESiJLT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.
A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. O T F CING,CONSULT YOUR LENDER OR AN ATTORNEY BEFORE
COMNiENCIN V�' OR RE �� TICE OF COMMENC T.
:i�` Nohry Public-State ol Florida
STATE OF FLORID :. Commistlon N fF 941793 * 1� i a e o r or Owner's Authorized Oflicer/Director/Mana r
couivzy oF rasc =� • w�omm.Eupyfra(.��uy.1�5,2020 �' �
���N�IRR���. * ��N �� '
PrmtNa�ieand itle
* n \ c
The foregoing instrument was aclmowled ed before me this � day of !7�Q� � ,20 ��,by �A� -Y�m�i
as (11� (type of authority, e.g. officer,trustee,
attorney in fact)for W name of n behal f who instrument was executed).
Personally Known OR Produced Identification Notary Signature � I
Type of Identification Produced - Name(print)
---AND ---
Verification pursuant to Section 92.525,Florida Statutes.Under penalties of perjury, I dec at I have read the foregoing and that
the facts stated in it are true to the best of my knowledge and belief. ,
*Foxnasrtaoc,rvsazoo�
Si e al Person Signing(in line#10)Above
s�3-�so-oozo City of Zephyrhills Fire Fax-813-780-0021
Permit Application
Date Received r Phone Contact for Permit �2� 5 3 0 4 5 21
�---~-- ..__.. _ __,.. .._---_-___ _ _ ..e�� _.....����
Owner'sName Stahl Family Farms LLC Owner'sPhoneNumber 72� 530 4521
Owner'sAddress P•O. Box 550, Jane Lew, WV 26378-0550
Fee Simple Titleholder Name Titleholder Phone Number � � �
Fee Simple Titleholder Address
r�"�' __�.�
JobAddress 40119 County Road 54 Zephyrhills, FL 33540� Lot# �
SubDivision Parcel# 06-26-22-000-01500-0020
�_.. ��. ._._.._ __ _.._.e.._�.�.. e,,__. -�---�:-�--_-�
� Bio-Hazard Waste Storage-ANNUAL � Fumigation Tent
. � Comm Exhaust Kitchen Hood/Duct � Hazardous Material(Tier II or RQ Facility)ANNUAL
� Controlled Burn � Hood Installation
� Emergency Generator<30 kw � LP/Natural Gas-Installation
� � Emergency Generator>30 kw � LP/Natural Gas-ANNUAL Sale
� Fire Protection Maintenance-ANNUAL � Places of Assembly-ANNUAL �
r y emi �n er /'� �/ �
��/ / �
Sprinkler � ❑ ❑ ❑ � Recreational Burn i/%X l
��
Fire Alarm � ❑ ❑ ❑ � � Sparkiers
Hood Cleaning � ❑ ❑ ❑ � Sprinkler System Instail '
Hood Suppression � ❑ ❑ ❑ � Standpipes(Sprinkler Sys)
ire -Installa on � Torch RoofinglTar Kettle
mps � Waste Tire Storage ANNUAL
� FlammableApplication-ANNUAL $3,781.00 Valuation of Project
� Fuel Tanks
, � Othef: Fire Protection A teration
�.__'.""'_'.. ....____ - __..W.�...v ._.�.. � �.�......n.�.��--�----�
', Contractor � Company Commercia Fire & Communications
Signature � Registered Y/N Fee Current Y/N
' Address 6510 125t Ave. N. Largo, FL 33773 License# 50901100012004
, ELECTRICIAN Company
Signature Registered Y/N Fee Current Y/N
Address License#
PLUMBER Company
Signature Registered Y/N Fee Current Y/N
i
Address License# ,
MECHANICAL Company
Signature Registered Y/N Fee Current Y/N
Address . License#
OTHER Company
Signature Registered Y/N Fee Current Y/N
Address License#
��-�'' _ .. ___._. __...___, _. �___.� _ - w....�,..�__ "" . ----s
Directions:
Fiil out application completely
Owner&Contractor sign back of application,notarized(Or,copy of signed contract with owner)
If over$2500,a Notice of Commencement is required(Mechanical work over$5000)
Supply two(2)sets of drawings with applicable documentation
Allow 10-14 days for review after submittal date. Parcel#-obtained from Property Tax Notice(http://appraiser.pascogov.com)
I
_. . . , . . :_ . .. -
: . . . .
1
=--= =— Above Ground P.o. Box 1350
� .� �� . --� ,
' - - ..,t/t-. �:...;:��:;, -;..;.�=�
' , � �''����'� -'�:-"=;,:� '-���� -`'' Largo, Florida 33779-1350
� _. v�� v ,Sprinkle� Piping
' CONIIII�RCIAL FIRE (`.727)-530-4521 50901100012004 " '
& COMMUNICATIONS SITE#:
�t.
Contractor's Material �and Test Certificate for Aboveground Piping ,=
PROCEDURE r� � z"`'
Upon completion of work,inspections and fests shall be made by the contractor's representative and witnessed by an owner's representative. All
defects shall be corrected and system left in service before contractor's personnel finally leave the job.
A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities,owners and contractor It is
understood that the owner's representative's signature in no way prejudices any claim against contractor for faulty material,poor workmanship or failure
, to com I with a rovin authori 's re uirements or local ordinances. �,�'`� �r,;i
- Property Name � /f ����� �OU t`� Date��� a��� '
�,� f
, Property Address �U / I � ������_� ;"'� �`�
s � i l�
Accepted by approving authorities(n�mes) �
, Address
, Plans Installation conforms to accepted plans ``0..Yes ❑ No
' Equipment used is approved `�'q Yes ❑ No �
If no, explain deviations
"" Has person in charge of fire equipment been instructed as '�,Yes ❑ No, �� .� -
,. to location of control valves and care and maintenance '
-- of this new equipment?
If no,explain
Instructions
Have copies of the following been left on the premises? ❑ Yes 0. No
� �'1. System components instructions ❑ Yes �[^�], No
". s� 2. Care and maintenance instructions ❑ Yes �� No
•� 3. NFPA 25 ❑ Yes �� No
Location of Supplies buildings
s stem
- Year of Orifice Temperature
Make Model manufacture size Quantit ratin
! LJ _r� L��.4.` "�C�/.� R�_'' � /S�'�'
Sprinklers � � � � �
� Pipe and Type of pipe Jc
fittin s T e of fittin s �'�-'� � / A Ca.�
, ' Maximum time to operate
Alarm valve Alarm device throu h test connection
or flow T e Make Model Minutes Seconds
indicator
D valve Q.O.D. � �
Make Model Serial no. Make Model Serial no.
' ' Time to trip Time water Alarm "
Dry pipe through test Water Air Trip point reached operated
� operating connection� ressure ressure air ressure test outlet� ro erl
� ��est Minutes Seconds si si si Minutes Seconds Yes No
' � Without � �
N/ � Q.O.D.
� _ With • � � ,
Q.O.D
If no explain
1 Measured from time inspector's test connection is opened
'�_F __ _ _ -" _ _ _. � . -
=—=— =— Above Ground � �
� �� �� � P.o. Box 1350
�.<,.z�i�� �=::� .:;�=;�
� --� �� �- � ��`` Largo, Florida 33779-1350
��- �� , � _ �y S p ri n k l:e r P i p i n g �-�727)_530-4521 50901100012004
CONIIN�RCIAL FIRE
& COMMUNICATIONS SITE#:
Operation � ,
❑ Pneumatic ❑ Electric ❑ H draulic ' ,.r;
�'"� Piping supervised ❑Yes ❑ No Detecting media supervised ❑Yes ❑ No �
,: ;.
`;:r, � Does valve operate from the manual trip, remote or both ❑Yes ❑ No
Deluge and control statioris?
preaction Is there an accessible facility in each circuit If no, explain
valves for testing? ❑Ye ❑ No
b. �. NA
N/A
' Does each circuit operate Does each circuit operate Maximum time to
Make Model su ervision loss alarm? valve release? o erate release
Yes No Yes No Minutes Seconds
' ❑ ❑ ❑ ❑
Pressure Location Make and Setting Static pressure Residual pressure Flow rate
reducing and floor model flowin � -
valv,�e test Inlet si Outlet si Inlet si Outlet si Flow m
i�
N/A� ❑ If checked, see attached listin for additional ressure reducin valves
Hvdrostatic: Hydrostatic tests shall be made at not less than 200 psi (13.6 bar)for 2 hours or 50 psi(3.4 bar)above
_ static pressure in excess of 150 psi for 2 hours. Differential dry-pipe valve clappers shall be left open during the test to '
Test Prevent damage. All aboveground leakage shall be stopped. .
description Pneumatic: Establish 40 psi air pressure and measure drop,which shall not exceed 1%psi(0.1 bar) in 24 hours. Test
�, pressure tanks at normal water level and air pressure and measure air pressure drop,which shall not exceed 1'/psi
0.1 bar in 24 hours. . �
; All piping hydrostatically tested at �(�� psi ( bar)for hours If no, state reason '
'�, Dry piping pneumatically tested ❑Yes ❑ No ❑ NA
� �;. E ui ment o erates ro erl ❑Yes ❑ No
� ; Do you certify as the sprinkler contractor that additives and corrosive chemicals, sodium silicate or derivatives of sodium
silicate, brine or other corrosive chemicals were not used for testing systems or stopping leaks?
❑ Yes ❑ No
Drain Reading of gauge located near water supply Residual pressure with valve in test�
Tests test test connection: si bar connection o en wide: si tf��3 bar
' Underground mains and lead-in connections to system risers flushed before connection made to
' sprinkler piping
' Verified by copy of the Contractor's Material and ❑Yes � No Other Explain
Test Certificate for Underground Piping '
� Flushed b installer of under round i in ❑Yes O,No '
' If powder-driven fasteners are used in concrete, ❑Yes ❑ No If no, explain
' has representative sample testing been 'qNA
satisfactoril com leted?
� Blank testing Number used Locations Number removed
askets
Welded i in � Yes ❑ No
, � If es... '
-Do you certify as the sprinkler contractor that welding procedures used complied with the �q Yes ❑ No ,
� minimum requirements of AWS B2.1,ASME Section IX Welding and Brazing Qualifrcations, � -
� or other applicable qualification standard as required by the AHJ?
'� �
� Do you certify that all welding was performed by welders or welding operators qualified in 0 Yes ❑ No
accordance with the minimum requirements of AWS B2.1,ASME Section IX Welding and '�,
Welding Brazing Qualifications, or other applicable qualification standard as required by the AHJ?
, \
� Do you certify that the.welding was conducted in accordance with a documented quality �� Yes ❑ No
' _ control procedure to ensure that(1)all discs are retrieved (2)that openings in piping are ��,
smooth;that slag and other welding residue are removed, (3)the intemal diameters of �
piping are not penetrated; (4)completed welds are free from cracks, incomplete fusion,
surface porosity greater than 1/16 in.diameter, undercut deeper than the lesser of 25% of
; the wall thickness or1/32 in.; and (5)completed circumferential butt weld reinforcement does ;
, not exceed 3/32 in.?
� =—=— =— �� Above .Ground P.o. Box 1350
� -� -� - ���
' � - �,a�:��-�;�.,:,.=h:�<si._,�,.
` � � —� � :�+�� .: "�� `''��` ;Largo, Florida 33779-1350
v� v � � : �Sprinkler Piping
COMN�RCIAL FIRE , � � . _ �(727)-530-4521 50901100012004
& COMMUNICATIONS " ' - SITE#:
� ,
-`,� I ' ,�,.
�4�- ' Do.you certify that you have a control feature to ensure that �-� ,
Cutouts all cutouts(discs) are retrieved? � � ��, Yes ❑ No
�d�s�� �; �f�g �rc�c-�--r nea .�; .S-��� . �
�""' � If no explain: " '
' Hydraulic Nameplate provided �Yes ❑ No
data
nameplate
. �
Sprinkler contractor removed all caps and straps? �,Yes ❑ No
Remarks Date left in service with all control valves open:
Name of sprinkler contractor�y �^ '
....��t`'��IYI�'-dCt�� P."/�C.."" ����8
Tests witnessed by �''�,�
The property owner or their authorized agent(signed) Title Date
Signatures •
For sprinkler contractor(signed) Title Date
. ' �'� " "�� � � -�
� ,�'l, �"" ��� ��°��Sr��. � .�rG� -
�. - -- _
Aciditional explanations and noter ���lr���-�( � �, �E�r�{S, ���� �������-S � ��'�j�fl ` -
L���-!� �ti'�--�'� � f
;},6 ,
�J' r.
� :�� .
n
.f�� . .
•.4'!s _
- '•:�{�'"..�, ' .
! �
'fi
.. , •, ,.
, , °'�-.
" ' _.�---� _
_ � ' � ` .;;:' ,
�� � . , , t _ .
��,n'; , , . ' .... rt� _
.�:� � , , .
_ ^.��
�. .
( '� � ijia Email
� ..�� � P.O. Box 1350, LARGO, FLORIDA 33779-1350 •-
� � �� �'�' � Submitted Date: 02/19/lb
�i� (727) 530-4521 Fax (727) 531-0596
(800)741-6507 (941)362-0486 Proposal# DC-744
�� ���MEi���.I.��R� EF0000785 FPC1 50901100012004
� ccMzr.�itTNiC3T?OA75 www.cfcsystems.com
� �` � ��°O�OS�l
Customer Name ' ' ,�ob Name
Viking Pools LLC Viking Pools LLC
401]9 Cr 54 East 40l 19 Cr 54 East
ZEPHYRHILLS,PL 33540 Zephyrhills,FL 33540
' Phone: (S13)783-7212 Fax: (8l3)783-7214
Phone: (813)783-7212 Fax:(813)783-7214
ATTN:THERESA ELLIOT Email:theresaellioit@lathampool.com
We suUmit the following pro posal to you in confidence,not to be disclosed without prior�vritten consent,to perform the
work in the following plans and speci�cations. This proposal may Ue withdra�vn if not accepted in 30 days.
Dr�win�Date:None 3pecification Sections: None Addendum # None
Rework existing Fire Sprinkler System in new sl�op area to comply with NFPA 13,Ordinary Hazard,Group 2(maa.
spacing= 130 sq.ft. per spklr} for proper coverage.
Demo existing semi-recessed fire spklrs/piping
'I Install new SSU spk]rs/piping,as required
Specificallxlncluded in this Proposal: ,S�ecificallv Fxcluded in this Pronosal
Pennit Additional devices required by local authority
Testing Additioaal devices required by owner
Drain and,fill of fire sprinkler system Any required fire watch
i
Patching and painting
Any overtime/weekend labor
�'he Sum of' $3�7g1.�o Three Thousand Sel�en Hundred L•ighty Orie D ollars And A�o Cenis
For value received and other considerations,the seller agrees with the buyer to provide the buyer with the listed products
in accordance witl�the terms and conditions of this proposal. Cancellation of proposal after acceptance will be billed for
restocking fee for materi�ls�nd labor charges for work performed througl�date of cancellation.
Terms: Due Upon Recei t
Options Selected
Signature ' Submitted by:
Drew Carpenter
Printed Name Sales&Estimating
Date of Acceptance PO# drewc@cfcsystems.com
�
,
.
" � � Comrnerciat �IRE
,. . ... ._. .
.� ..� ��.
�� �► �i Communications,lnc.
6510-B 125th Avenue N. P.O. Box 1350 Phone(727)530-4521
Largo, FL 33773 Largo, FL 33779-1350 Fax(727)531-0596
Viking Pools
40119 County Road 54
Zephyrhills, FL 33540
I Fire Snrinkler Equipment Submittal
Description Manufacturer Part#
SPRINKLERS:
Upright (QR,SC) Tyco TY3131
i
FIl"TINGS:
Threaded Fittings AnvilStar Cast Iron
Threaded Fittings AnvilStar Ductile Iron
PIPE:
�Black' Steel Wheatland Sch.10/40
� HARDWARE:
Loop Hanger Erico 100 Series
MSDS:
Cutting Oil
Thread Sealant
' Teflon Tape ,
�
Fu/l Service Alarm& Communications Contractor
License#5090110001Z004
r •
� �
II
1.
'�"(,�C'Q Fire �r Building
PYaducts
Technical Services:Tel� (800)381-9312/Fax: (800)791-5500
� . �
Ser�es TY FRB 2.8, 4.2, 5.6, and 8.0 K-factor
Upright, Pendenf, and Recessed Pendent Sprinklers
� Quick Response, Standard Coverage
� General tained when exposed to corrosive at- _
mospheres. Although corrosion resis- -�`�- --:���--
tant coated sprinklers have passed the ,�����n --� - ~=��:
Description standard corrosion tests of the appli- :="�"+`�, `���." ' """
; "'T���, ~t
cable approval agencies,the testing is =-=.;
The Tyco� Series TY-FRB, 2.8, 4.2, not representative of all possible cor- � +'
5.6,and 8.0 K-factor, Upright and Pen- rosive atmospheres. Consequently, it �-�'� �
dent Sprinklers described in this data is recommended that the end user be '
sheet are quick response - standard consulted with respect to the suitability �w � ��-- , � �
coverage, decorative 3 mm glass bulb of these coatings for any given corro- �'�'., . , : �-.,..:.d,�.�
type spray sprinklers designed for use sive environment.The effects of ambi- � }"�- U~� � ` -"
in light orordinary hazard,commercial ent temperature, concentration of • `'"��iYf
s�a .�y. ,
occupancies such as banks, hotels, chemicals, and gas/chemical velocity, � `ry' '_�^___ � ��
shopping malls, etc. should be considered, as a minimum,
The recessed version of the Series along with the corrosive nature of the
TY-FRB Pendent Sprinkler,where ap- chemical to which the sprinklers will be �
plicable, is intended for use in areas exposed. _
with a finished ceiling. It uses either a An intermediate level versions of the - :_�°��._
two-piece Style 10 (1/2 inch NPT) or Series TY-FRB Pendent Sprinklers ��� �;�
Style 40(3/4 inch NPT) Recessed Es- are detailed in Technical Data Sheet ;
cutcheon with 1/2 inch (12,7 mm) of TFP356, and Sprinkler Guards are de- '� % $.
recessed adjustment or up to 3/4 inch tailed in Technical Data Sheet TFP780 "' � �',�
� ,;.- �.�,,,,.,.
(19,1 mm)of total adjustment from the '� •�?.. ��
flush pendent position, or a two-piece WARNINGS � �' *,, �;R
Style 20(1/2 inch NPT)or Style 30(3/4 The Series TY-FRB Sprinklers de- '''��•b_�-��`= _,�� _
inch NPT) Recessed Escutcheon with scribed herein must be installed and ~n�",�"-�
1/4 inch (6,4 mm)of recessed adjust- maintained in compliance with this
ment or up to 1/2 inch (12,7 mm) of document,as well as with the applica-
total adjustment from the flush pen- b/e standards of the National Fire Pro-
dent position. The adjustment pro- fection Association, in addition to the
vided by the Recessed Escutcheon re- standards ofanyofherauthorities hav- M�de1�sPr�nk'er
duces the accuracy to which the fixed ing jurisdiction. Failure to do so may
pipe drops to the sprinklers must be impair the performance of these de- ,dentification
cut. vices.
Corrosion resistant coatings, where The owneris responsible formaintain- NLIlnberS
applicable, are utilized to extend the ing their fire protection system and de-
life of copper alloy sprinklers beyond vices in proper operating condition. TY1131 - Upright 2.8K, 1/2"NPT
that which would otherwise be ob- The insta/ling contractor or sprinkler TY1231 - Pendent 2.8K, 1/2"NPT
manufacturer should be contacted TY2131 - Upright 4.2K, 1/2"NPT
wifh any quesfions. TY2231 - Pendent 4.2K, 1/2"NPT
IMPORTANT TY3131 - Upright 5.6K, 1/2"NPT
Always refer to Technical Data TY3231 - Pendent 5.6K, 1/2"NPT
Sheef TFP700 for the "INSTALLER TY4131 - Upright 8.OK,3/4"NPT
WARNING" that provides cautions TY4231 - Pendent 8.OK,3/4"NPT
with respect to handling and instal- TY4831- Upright 8.OK, 1/2"NPT
lation ofsprinklersystemsand com- TY4931- Pendent 8.OK, 1/2"NPT
ponents. Improper handling and in-
sta/lation can permanently damage
a sprink/er system or its compo-
nents and cause the sprinkler to fail
to ope�ate in a fire situation or cause
if to operate premature/y.
Page 7 of 10 � AUGUST, 2007 TFP171
;.
TFP171 Page 3 of 10
ESCUTCHEON 7/16"(11,1 mm) STYLE 10 or 20
PLATE SEATING NOMINAL RECESSED *
SURFACE NPT �-IN ESCUTCHEON DEFSECTOR
� 6*
2-3/16" �_ 7/16" 5
(11,1 mm)
(55,6 mm) NOMINAL 4
MAKE-IN
1-1/2" � 2-3/16�� 2
(38,1 mm) WRENCH
(55,6 mm) 3
FLATS
. �
. SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. � 1/2"NPT
• PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION
1-Frame 3-Sealing a-Bulb 6-oefiector * Temperature rating is indicated on deflector or adjacent to
2-Button Assembly 5-Compression orifice seat on frame.
Screw
FIGURE 3
QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY3931)AND PENDENT(TY3231)SPRINKLERS
5.6 K-FACTOR, 1/2/NCH NPT
ESCUTCHEON 1/2"(12,7 mm) STYLE 30 or 40
i PLATE SEATING NOMINAL RECESSED *
SURFACE 3�4 MAKE-IN ESCUTCHEON SSU
NPT � DEFLECTOR
� — 6*
1/2" 5
2-5/16" (12,7 mm)
(58,7 mm) NOMINAL 4
MAKE-IN
1-9/16" I 2-1/4" 2
(39,7 mm) WRENCH (57,2 mm)
FLATS 3
:
* � 1
SSP DEFLECTOR 2-7/8"(73,0 mm)DIA. 3/4"NPT
PENDENT REC6SSED PENDENT UPRIGHT - CROSS SECTION
1-Frame 3-Sealing 4-Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to
2-Button Assembly 5-Compression orifiCe seat on ffame.
Screw ,
FIGURE 4
QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4131)AND PENDENT(TY4231)SPRINKLERS
8.0 K-FACTOR, 3/4/NCH NPT
TFP171 Page 5 of 10
SPRINKLER FINISH(See Note 7)
K TYPE TEMP. BULB NATURAL CHROME WHITE***
LIQUID BRASS PLATED POLYESTER
135°F/57°C Orange
PENDENT 155°F/68°C Red
TY1231
and
175°F/79°C Yellow �.2,3,5
UPRIGHT 200°F/93°C Green
2 8 (TY1131)
286°F/141°C Blue
1/2"
NPT 135°F/57°C Orange �
. RECESSED 155°F/68°C Red
PENDENT
(TY1231)* 175°F/79°C Yellow
Figure 6 200°F/93°C Green 1,2,5
135°F/57°C Orange
� RECESSED
PENDENT �55°F/68°C Red
(TY1231)'* 175°F/79°C Yellow
Figure 7 200°F/93°C Green
135°F/57°C Orange
PENDENT 155°F/68°C Red
(TY2231)
and 175°F/79°C Yellow
UPRIGHT 200°F/93°C Green
4.2 �TY2131)
286°F/141°C Blue � 2
1/2"
NPT 135°F/57°C Orange
RECESSED �55°F/68°C Red
PENDENT
(TY2231)" 175°F/79°C Yeilow
, Figure S 200°F/93°C Green
135°F/57°C Orange
RECESSED 155°F/68°C Red
PENDENT
(TY2231)" 175°F/79°C Yellow
Figure 9 200°Fl93°C Green ,
NOTES:
1 Listed by Underwriters Laboratories, Inc.(UL)as Quick Response Sprinklers.
2.Listed by Underwriters Laboratories, Inc.for use in Canada(C-UL)as Quick Re-
sponse Sprinklers.
3 Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprin-
klers.
5 Approved by the City of New York under MEA 354-01-E.
7 Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprin-
klers are UL and C-UL Listed as Corrosion Resistant Sprinklers.
' Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment
Recessed Escutcheon,as applicable.
**Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment
Recessed Escutcheon,as applicable.
"`Frame and Deflector only Listings and approvals apply to color(Special Order).
N/A. Not Available
TABLE A
LABORATORY LISTINGS AND APPROVALS
2.8 AND 4.2 K-FACTOR SPRINKLERS
TFP177 Page 7 of 10
SPRINKLER FINISH
K TYPE NATURAL CHROME WHITE LEAD
BRASS PLATED POLYESTER COATED
P,ENDENT(TY3231)
and
2 g UPRIGHT(TY3131) 175 PSI(12,1 BAR) N/A
��2 RECESSED PENDENT
NPT (N323)
PENDENT(TY4231)
, and
4.2 UPRIGHT(TY4131) 175 PSI(12,1 BAR) N/A
3/4" RECESSED PENDENT
. NPT (�'4231)
PENDENT(TY3231)
and 250 PSI(17,2 BAR) 175 PSI(12,1 BAR)
5.6 UPRIGHT(TY3131) OR
1�2 RECESSED PENDENT ��5 PSI(12,1 BAR)
N PT (TY3231)
(SEE NOTE 1) N/A
PENDENT(TY4231)
and 175 PSI(12,1 BAR) 175 PSI(12,1 BAR)
g p UPRIGHT(TY4131)
3�4 RECESSED PENDENT
N PT (TY4231) N/A
i 8.0 PENDENT(TY4931)
1/2" and 175 PSI(12,1 BAR) 175 PSI(12,1 BAR)
NPT UPRIGHT(TY4831)
NOTES:
1 The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories Inc.(UL);the Listing by
Underwriters Laboratories, Inc.for use in Canada(C-UL);and,the Approval by the City of New York.
TABLE C, MAXIMUM WORK/NG PRESSURE
fained with a torque of 10 to 20 ft.lbs. the sprinkler into the sprinkler fitting.
Installation (13,4 to 26,8 Nm). A maximum of 30 Step 3. Tighten the sprinkler into the
ft.lbs.(40,7 Nm)of torque is to be used
The Series TY-FRB Sprinklers must to install sprinklers wifh 3/4 NPT con- sprinkler fitting using only the W-Type
be installed in accordance with the fol- nections. Higher levels of torque may 6 Sprinkler Wrench (Ref. Figure 14)
lowin instructions: With reference to Figures 1, 2, 3, 4,
9 � distort the sprinkler inlet and cause and 5,the W-Type 6 Sprinkler Wrench
leakage orimpairment of the sprinkler. is to be applied to the sprinkier wrench
NOTES
Do not insta/l any bu/b type sprinkler if Do not attempt to make-up for insuffi- flats.
the bu/b is cracked or fhere is a loss of cient adjustmenf in the escutcheon The Series TY-FRB Recessed Pen-
liquid from the bulb With the sprinkler plate by under- or over-tightening the dent Sprinklers must be installed in
held horizonfally, a small air bubble sprinkler. Readjust the position of the accordance with the following instruc-
should be present. The diamefer of the sprinkler fifting to suit. tions
air bubble is app�oximately 1/16 inch The Series TY-FRB Pendent and Up- Step A. After installing the Style 10.
(1,6 mm) for the 135°F/57°C to 3/32 right Sprinklers must be installed in 20, 30,or 40 Mounting Plate,as appli-
inch (2,4 mm) for the 286°F/141°C accordance with the foliowing instruc- cable, over the sprinkler threads and
temperature ratings. tions. with pipe thread sealant applied to the
Aleaktight9/2inchNPTsprinklerjoint Step 1. Pendent sprinklers are to be Pipe threads, hand tighten the sprin-
should be obtained with a tor ue of 7 kler into the sprinkler fitting.
9 installed in the pendent position, and
to 14 ft.lbs. (9,5 fo 99,0 Nm).A maxi- upright sprinklers are to be installed in Step B. Tighten the sprinkler into the
mum of 29 ft. Ibs. (28,5 Nm)of torque the upright position. sprinkler fitting using only the W-Type
may be used fo install sprinklers with Step 2. With pipe thread sealant ap- � Recessed Sprinkler Wrench (Ref.
1/2 NPT connecfions. A leak tight 3/4 plied to the pipe threads, hand tighten Figure 15).With reference to Figure 1,
inch NPT sprinkler joint should be ob- 2, 3, and 4, the W-Type 7 Recessed
TFP771 Page 9 of 10
2-7/8"DIA. 2-7l8"DIA.
5/8f1%4" (73,0 mm) 3/4"(19,1 mm) 1/2±1/8" (73,0 mm) 1/2"(12,7 mm)
(15,9±6,4 mm) Z_1/4"DIA. 1/4"(6,4 mm) (12,7t3,2 mm) 2_�/4"DIA. 1/4"(6,4 mm)
FACE OF (57,2 mm) � MOUNTING FACE OF (57,2 mm) � MOUNTING
SPRINKLER p�qTE SPRINKLER PLATE
FITTING FITTING
1/8" 1/8"
(3,2 mm) (�m)
� � \
MOUNTING
MOUNTING SURFACE
SURFACE
. CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-1/4"(31,8 mm)
TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm)
, FIGURE 10 FIGURE 91
SER/ES TY-FRB RECESSED PENDENT SER/ES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON
5.6 K-FACTOR, 1/2 INCH NPT 5.6 K-FACTOR, 1/2 INCH NPT
2-7/8"DIA. 2-7/8"DIA.
5/8t1/4" (73,0 mm) 3/4"(19,1 mm) ��zt��$„ (73,0 mm) 1/2"(12,7 mm)
(15,9±6,4 mm) 2-1/4"DIA. 1�4"(6,4 mm) ��2,7±3,2 mm) 2-1/4"DIA. 1/4"(6,4 mm)
(57,2 mm) � MOUNTING FACE OF (57,2 mm) � MOUNTING
FACE OF
SPRINKLER PLATE SPRINKLER PLATE
FITTING FITTING
1/8" 1/8"
(3,2 mm) (3,2 mm)
� � �
MOUNTING
MOUNTING SURFACE
SURFACE
CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16"(33,3 mm)
TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm)
FIGURE 12 F/GURE 93
SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4/NCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON
8.0 K-FACTOR, 3/4 INCH NPT 8.0 K-FACTOR,3/4 INCH NPT
pleted,to verify the integrity of the cor- wRENCH
rosion resistant coating Thereafter, RECESS
annual inspections per NFPA 25
should suffice, however, instead of in- / WRENCH RECESS �
specting from the floor level,a random � (END"A"USED FOR
sampling of close-up visual inspec- 1/2��NPT MODELS) n
tions should be made, so as to better `U
determine the exact sprinkler condi-
tion and the long term integrity of the �.•
corrosion resistant coatin as it ma WRENCH RECESS
g' y (END"B"USED FOR PUSH WRENCH
be affected by the corrosive conditions 3/4"NPT MODELS) IN TO ENSURE I
p�gSe�t. ENGAGEMENT
FIGURE 14 WITH SPRINKLER �i
The owner is responsible for the I11- WRENCHINGAREA
spection, testing, and maintenance of W-TYPE 6 SPRINKLER
their fire rotection s stem and de- WRENCH FIGURE 15
vices in ompliance with this docu- W-TYPE 7 RECESSED I
ment, as well as with the applicable SPRINKLER WRENCH
standards of the National Fire Protec- facturer should be contacted relative
tion Association (e.g., NFPA 25), in to any questions.
addition to the standards of any other It is recommended that automatic Inspection Service in accordance with II
authorities having jurisdiction The in- sprinkler systems be inspected, local requirements and/or national
stalling contractor or sprinkler manu- tested,.and maintained by a qualified codes I
.. /��St�rTM ��Z /.1iWIL.
SPFT"" Cast Iron Threaded Fittings U� U�C
FM
APPROVED
SPFT"'Cast Iron Threaded Fittings pre r-,.____.. -- , f
UL/ULC Listed and FM Approved for '� '°�}
300 psi service. These fittings are avail- ( ~_ - - _
able in a range of styles and specifica- ��
tions. All SPFT"'Cast Iron Threaded ' '� - �;,;;,�
Fittings dimensions conform to ANSI , �,
B16.4 Class 125 requirements, and ,y�;�`� . �° �
threcds are NPT per ANSI/ASME _,,;:
B 120.1 '{�
y ,�
1
� �
t - ���'
r_-v.�.sw.-_�:�.:�>_-.,�.�.��.d...:•;�.:_�.f:r.-_..�..,<.,�-,.u: _„�-,-_ ..w.._..._.,-t-=..tl..M�_-.--.-.r-s.n-.,..,..�r�::1._.:�._.....a.:::.:-.v:.._a.. t.'..--'�. --_--• _..�. ,1---�.....-- ._�_z�-_,.,, „ .x:,.�_.z....
������������ ��, ����` ������ ���� � ������ ����� �������� ��t�����
�3�F I�t��ii� Ir�ri it���•� ; �i��a�b�.�fr� UL�'
---- -- --- -- - - -- ----
t��� �i����nd �����a���roti�d�v�r�c�t�psi
�n�'�.The��diCLin��pF���i��� ��;��n�J�bl�
1�a��dr,��a�ae�i�at�43n� �s�: ����i��l'� ir� � ' � �:,-
r�n��am st�p�te�.ar�d s�e�lic�,1'stins.a�ll �P�E .� -
Ca�aclil�ir��TF���a��'ed��1.�is�b��c�ir�H�ir�s��ifis
�uanf�aasn ta��,�l�I �t���I�.�� �5�� re�uir�- . . _ �- ;��.
iritnt���nd Cl�r���l��s�t f�J�T�ei u�R51,��5hiE � � � � E -r
C�9.'�CI.1_ �! � .
� �.
����a�� fa�an`a'}er��d�3 �=ikti►����r�4�a�'�r�� _ �� -
Li�t�� �nd f�'�.�P�pp�r�r�d!ar 31]4 �5i �i�ra�ic�_ �
Ti�e� Ftler�w a�� ��t�if�l�f� i� a��n�� €�� �` �.."',
s��yd�s aa��speci:ic�ic�n�All SPF��sC lron _ ,m94 �-�'�;
Tiirc�d�d Fitkin��a�arsi�r�yi€�4i� �c��€��r�� i� -� -
a'�P�fS� �16_+� ��quir�m�r,t�,.and 1;h:reads.�r� ��',� r�� -
�PT p��r���1�"�5�,�1E �1,��.1� a��E� �����,��
;, :.� , � �
'I p{�y{��l n n F1 ,r,ry '�w�..e �yJ{ ,A�s
` ` ITdYTIR4MJ°h'T'04?i44�L �rt§h'&'k'eic�il����l{.�l�1.1J�� ����'+�+ d '��������+'
h f�t'�.7 3
Wheatland's
Sched u le 10
Sprinkler Pipe
Wheatland's Schedule 10 Sprinkler Pipe is a high quality sprinkler pipe offering you the full
range of assurances you require. Schedule 10 Sprinkler Pipe has passed some of the
toughest lab tests ever created for sprinkler pipe.
Made in the U.S.A. by Wheatland Tube Com- Specifications and Approvals
pany means made to the highest standards for
consistant quality.
Wheatland's schedule 10 Sprinkler Pipe is made Wheatland's Schedule 10 Lightwall
from the highest quality steel in one of the Sprinkler Pipe meets or exceeds the
nation's most modern and most complete pipe following:
manufacturing plants. Our proprietary mill coating
offers you a clean, corrosion and heat resistant • UL Listed
surface that outlasts and outperforms standard • FM Approved
lacquer coatings. Plus, this coating can be • ASTM A135, Grade A
quickly and easily painted without special
preparation. Or it may be hot-dipped galvanized
to meet FM requirements for dry systems in Please refer to appropriate documentation for
accordance with the zinc coating specification of up-to-date listing and approval information.
ASTM A795 or A53. Specifications and descriptions are accurate as
known at time of publication and are subject to
change without notice.
Specifications
Nominal O.D Nominal I.D Nominal Wall Nominal Weight Pieces
NPS UL CRR' Lift
in. mm in. mm in. mm Ibs./ft. kg/m
1 �/4 1.660 42.2 7.442 36.6 .109 2.77 1.81 2.69 7.3 61
� �/2 1.900 48.3 7_682 42.7 .109 2.77 2.09 3.1 1 5.8 67
2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37
2 1/2 2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30
3 3.500 88.9 3.260 82.8 .�20 3.05 4.34 6.46 2.6 7 9
4 4.500 1 14.3 4.260 7 08.2 .120 3.05 5.62 8.37 1.6 �9
5 5.563 y 47.3 5.295 134.5 .134 3.40 7.78 1�.58 1.5 13
6 6.625 168.3 6.357 7 67.5 .7 34 3.40 9.30 �3.85 y.O �O
*Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY
, 'The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Schedule 40 steel pipe is used as the
benchmark(value of 1.0).
,�yjt�Y:s.
"�� �WheatlandTube Company
�i;.
1 Council Avenue, P.O. Box 608 Wheatland, PA 1 61 61-0608
Ph 800.257.8182 Fax 724.346.7260
www.wheatland.com 0207 1.OMrev01
SWIVEL LOOP HANGER 100 �� ��'� ' � �
.. , �
, -2__ ,.�y'=..:r°-�;,�,�,.
Heavy Duty Adjustable Band Hanger '��W' �, i -�������� `"t
� __ �. �,
• Size Range: 1/2" through 8" y , tr �:� 1�'
, �,, . �l . '�.
• Surface Finish: Electro-zinc plated P��_
• Recommended for the suspension of stationary ���;;--��.:� _ -� �
`��--�. �" � '��� _ ,��
non-insulated pipe lines -�_�;� �-�_�� _
:.�4 -
• Features a retained insert nut to ensure that the � �-�$� �� �3
loop hanger and insert nut stay together
.�
• Conforms with Federal Specification WW-H-171 (Type 10), `'`�� ��
Manufacturers Standardization Society (MSS) SP-58 and
��` � �
SP-69 (Type 10) � �
��- �; 4� .��s:�
��,
k�`�;i,b'r
k�
• / ��i •
• - ' e - - • . � •
1000050EG 1/2" 3/8" 2-3/4" 1 " 300 3/4" - 8" 12" - 8"
1000075EG 3/4" 3/8" 3-1/16" 1 " 300 FM
1000100EG 1 " 3/8" 3-5/16" 1 " 300 c U� us
APPROVED
1000125EG 1-1/4" 3/8" 3-9/16" 1 " 300
1000150EG 1-1/2" 3/8" 3-13/16" 1 " 300 RS �{ �
1000200EG 2" 3/8" 4-1/4" 1 " 300 �
1000250EG 2-1/2" 1/2" 5-5/8" 1-1/4" 1000
1000300EG 3" 1/2" 6-9/16" 1-1/4" 1000 B
1000350EG 3-1/2" 1/2" 7" 1-1/4" 1000 �
1000400EG 4" 5/8" 7-3/4" 1-5/16" 1100 A
1000500EG 5" 5/8" 9-1/8" 1-5/16" 1100
1000600EG 6" 3/4" 10-5/8" 1-9/16" 1250
1000800EG 8" 7/8" 13-1/8" 1-5/8" 1250
Section IV—Fire and Explosion Hazard Data
� Flash Point(Method Used) Flammable Limits LEL UEL
300°F(COC)
Extinguishing Media
Dry Chemical,Foam,CO
Special Fire Fighting Procedures �
Firefighters should wear self-contained breathing apparatus.
Unusual Fire Exp(osion Hazards
None
� Section V—Reactivity Data
Stability Unstable Conditions to Avoid
None
Stable X
Incompatibility(Materials to avoic�
Strong oxidizing agents
Hazardous Decomposition or Byproducts
CO,CO2
Hazardous May Occur ❑ Conditions to Avoid
polymerization None
Will Not Occur �
(Reproduce locally) OSHA 174,Sept. 1985
Section VI —Health Hazard Data
Route(s)ofEntry• Inhalation? Skin? Ingestion?
Possible Possible Possible
Health Hazards(Acute and Chronic)
No known acute health hazards;prolonged or frequent use may cause mild skin and eye irritation.Target organs
(oil mist),respiratory system and skin.
Carcinogenicity• NTP? IARC Monographs? OSHA Regulated?
None known
Signs and Symptoms of Exposure
Possible red and/or itching skin due to overexposure.
Medical Conditions Generally Aggravated by Exposure
None known
Emergency and First Aid Procedures
Eye contact:flush with water for at least 15 minutes and seek medical attention immediately.
Skin contact:wash with soap and water.
Inhalation:if a person breathes in large amounts of this product,move the exposed person to fresh air at once.
Section VII— Precautions for Safe Handling and Use
,•
Product Name.PipeFitO
Preparation Date.January 11,2010
Page 1 of 6
SAFETY DATA SHEET
Section 1: Product and Company Identification
Product Name: PipeFit�
Product Code: 46030 1pt. BIC, 46031 1 qt., 46032 1 Gal., 46033 5 gal., 46034 55 gal., 46048 1 qt. BIC
Product Use: Pipe thread sealant
Manufacturer: Fire Protection Products Inc.
6241 Yarrow Drive
Suite A
� Carlsbad, CA 92011-1541
Phone Number: 1-800-344-1822
2d-hour Emergency: CHEMTREC: (800)424-9300
Section 2: Hazards Identification
Protective NFPA Rating EU WHMIS
Clothing (USA) Classification (Canada) Transportation
�, i � Not classified as
� � �,Q dangerous �, Not Regulated
� Not controlled
Emergency Overview: Exposure to hazardous substances is not expected when handling this product for its intended
use. Extreme'heating(>300°C)or during a fire may generate dense smoke, irritating and toxic
fumes.
Appearance,Color and Odor: White-cream colored paste with mild odor
USA. This material is not considered hazardous by the OSHA hazard Communication Standard
(29 CFR 1910 1200).
Canada: This is not a controlled product under WHMIS
European Union(EU): This product is not classified as dangerous according to Directive
1999/45/EC and its amendments.
Potential Health Effects ACUTE(short term):see Section 8 for exposure controls
Pipefit0 does not present an inhalation, ingestion, or contact health hazard unless subjected to
extreme heating.
Relevant Route(s)of Exposure: Skin contact.
Inhalation: No health effects expected with normal use of the product.
Extreme heating(>300°C)of the product can release irritating vapors. Symptoms of irritation
include coughing,sneezing, nasal discharge, headache, hoarseness and pain in the upper
respiratory tract.
Products of thermal decomposition of fluorocarbon monomers and polymers can produce a
condition known as"polymer-fume fever";the symptoms are flu-like(chills, headache and fever)
with chest tightness and mild cough, onset of symptoms may be delayed.
Ingestion: Not an expected route of occupational exposure. Acute oral toxicity of the component substances
is low
Skin: No adverse health effects expected with normal use of the product.
Eye: Direct eye contact may cause temporary irritation as a foreign object in the eye. Symptoms of
irritation include redness, swelling, pain and blurred or hazy vision.
.: •
Product Name:PipeFitO
Preparation Date.January 11,2010
Page 3 of 6
SAFETY DATA SHEET �
Section 5: Fire Fighting Measures, continued
Specific Hazards arising from the Chemical: During a fire, products of combustion may include Hydrogen fluoride, Perfluoro-
carbon olefins and oxides of carbon.
Irritating and harmful fumes are released when PTFE is heated above 300°C The
decomposition products and the resulting health effects are temperature-dependent.
Protective Equipment and precautions for Self-contained breathing apparatus and protective clothing should be worn.
firefighters: Remove all unprotected personnel.
N�PA
Health: 0
Flammability: 0
. Instability: 0
Section 6: Accidental Release Measures
Personal Precautions: Spilled product may pose a slipping hazard.
Environmental Precautions: Prevent the product from entering sewers or waterways.
Methods for Containment: Not applicable
Methods for Clean-up: Pick up spilled product and collect for re-use or proper disposal. Dispose of any
contaminated, unusable product as described in Section 13 of this SDS.
Section 7: Handling and Storage
Handling: Avoid contact with eyes and skin;do not breathe fumes. Do not use near sources
of extreme heat. Keep out of reach of children.
Wash thoroughly with detergent and water after handling, before eating, drinking,
smoking or using the foilet.
Storage: Store in a cool, dry area, away from heat,flames and ignition sources.
' Section 8: Exposure Controls/Personal Protection
� Exposure Guidelines
' Measurable airborne concentrations of the component substances, listed in Section 3, are not expected when product is used as
directed on the label for its intended purpose.
Exposure Controls
Engineering Controls: Not required for normal use If product is overheated, provide adequate ventilation to keep fume .
concentrations below any applicable exposure limits. Consult local authorities for acceptable
exposure limits.
Personal Protection:
Eye/Face Protection: No special requirements.
Skin Protection: Wear appropriate gloves when needed to prevent skin contact.
Respiratory Protection: Not required for normal use.
A respiratory protection program that meets OSHA's 29 CFR 1910 134 and ANSI Z882
requirements, European Standard EN529 or Canadian Standards Association(CSA)Standard
Z94 4-2002 must be followed whenever workplace conditions warrant a respirator's use.
General Hygiene Measures: Do not ingest.Avoid contact with skin and eyes. Keep out of reach of children. Wash hands after
handling.
'' II
A Product Name.Pi eFit�
P
Preparation Date:January 11,2010
Page 5 of 6
SAFETY DATA SHEET
Section 11: Toxicological Information (continued)
Chronic Toxicitv Data
Carcinogenicity: Light Naphthenic hydrotreated distillates, has less than 3% DMSO extract as measured by IP 346
This product is not required to be labeled according to the European Directive 67/548/EEC
IARC Group 3, Not classifiable as to its carcinogenicity in humans.
ACGIH A4, Not classifiable as a human carcinogen.
• Inqredient ACGIH IARC NTP
Light Naphthenic hydrotreated Not listed Group 3 Not listed
distillates
Ethanol A4 Not applicable Not applicable
PTFE Not listed Group 3 Not listed
ACGIH: (American Conference of Governmental Industrial Hygienists)
IARC� (International Agency for Research on Cancer)
NTP� (National Toxicology Program)
Irritation: Not available
Corrosivity: Not applicable
Sensitization: Product contains a substance which may cause an allergic skin reaction. There is no test data
available for the product.
Neurological Effects: Not available
Genetic Effects: Not available
Reproductive Effects: Not available
Developmental Effects: Not available
Target Organ Effects: Not available
Section 12: Ecological Information
Ecotoxicity: Ecotoxicity is expected to be low due to the producYs insolubility in water
Persistence/Degradability: Not available
Bioaccumulation/Accumulation: Product is not readily biodegradeable.
Mobility: Not available
Section 13: Disposal Considerations
Waste Disposal Method: Do NOT discard into any sewers, on the ground or into any body of water Store material for
disposal as indicated in Section 7 Handling and Storage.
The conditions of use, storage and disposal of this product are beyond our control and may be
beyond our knowledge. For this and other reasons, the supplier does not assume responsibility
and expressly disclaim liability for loss, damage or expense arising out of or in any way
connected with the handling, storage, use or disposal of this product.
USA: Dispose of in accordance with local, state and federal laws and regulations.
Canada: Dispose of in accordance with local, provincial and federal laws and regulations.
EU: Waste must be disposed of in accordance with relevant EU Directives and national, regional and
local environmental control regulations. For disposal within the EU,the appropriate code
according to the European Waste Catalogue(EWC)should be used.
. .
Material Safety Data Sheet U.S. Department
Labor
May be used to comply with Occupational Safety and Health
Administration
OSHA's Hazard Communication Standard (Non-Mandatory Form)
29 CFR 1910.1200 Standard must be Form Approved
consulted for specific requirements. OMB No. 1218-0072
• IDENTITY(As Used on Label and List) Note:Blank spaces are not permitted.If any item is not
PTFE Thread Seal Tape applicable,or no information is available,the space must be
marked to indicate that.
�
Section I
Manufacturer's Name Emergency Telephone Number
Fire Protection Products,Inc. Call CHEMTREC 1 800 424-9300 or 1 703 527-3887
Address(�tttmber,Sb•eet, City,State,a�id Zip Code) Telephone Number for Information
6241 Yarrow Dr.,Ste.A 760 931-1168
Date Prepared
Carlsbad,CA 92011 7/26/2007
Signature of Preparer(optionan
' Section II—Hazard Ingredients/Identify Information
Hazardous Components(Specific Chemical Other Limits
Identity;Common Name(s)) OSHA PEL ACGIH TLV Recommended %(optional)
Pol tetraflouroeth lene 90-100% Thermal decom osition of the fluorocarbon chain in air leads to
the formation of oxidized roducts containin carbon,fluorine
and ox en.Because these roducts decom ose in art b
Yg P P P Y
hydrolysis in alkaline solution,they can be quantitatively provided
an index of ex osure.No TLVs are recommended at this time,but
Air concentration should be controlled as low as possible.
�
�
Section VI—Health Hazard Data
Route(s)of Entry: Inhalation? Skin? Ingestion?
See Health Hazards N/A N/A
Health Hazards(Acute and Claronic)Unheated fluorocarbon polymer is inert and there is no known instances of health
hazard,when handling the unheated product.When heated at high temperature,it will thermally degrade,decompose and
produce toxic fumes.Inhalation of such fumes will cause"Polymer Fume Fever",which has symptoms very similar to
influenza and can include headache,cough,fever,chills and chest discomfort.The symptoms do not occur until several
hours after exposure and may pass within 36 to 48 hours,even in the absence of treatment.
� Carcinogenicity: NTP? IARC Monographs? OSHA Regulated?
Polytetrafluoroethylene N/A 3-Not classifiable as its N/A
carcino enicity to humans
�
Signs and Symptoms of Exposure
N/A
Medical Conditions Generally See Health Hazards
Aggravated by Exposure
Emergency and First Aid Procedures
N/A
Section VII— Precautions for Safe Handling and Use
Steps to Be Taken in Case Material is Released or Spilled
N/A
Waste Disposal Method
Do not incinerate.Obey local rules,laws and regulations.
Precautions to Be Taken in Handling and Storing
Keep away from heat and sources of ignition.
Other precautions
Do not use for body transplantation and a contact with living body tissue and body fluids.
i
r