Loading...
HomeMy WebLinkAbout16-16963 � � CITY OF ZEPHYRHILLS • • 5335-8TH STREET (813)780-0020 169 BUILDING PERMIT � PERMIT INFORMATION LOCATION INFORMATION � Permit Number: 16963 Address: 3828 LAUREL VALLEY BLVD LOT�45 Permit Type: ADDITION/ALTERATION ZEPHYRHILLS, FL. Class df Work: 434-ADD/ALT RESIDENTIAL Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: MAJESTIC OAKS Est. Value: Parcel Number: 24-26-21-0000-00100-0090 Improv. Cost: 19,000.00 OWNER INFORMATION �� Date Issued: 1/26/2016 Name: NHC-FL115 LLC (GENE SHELLEY) Total Fees: 195.00 Address: 6991 E CAMELBACK RD STE B310 Amount Paid: 195.00 SCOTTSDALE AZ 85251-2493 Date Paid: 1/26/2016 Phone: (443)591-1708 Work Desc: WOOD DECK & SCREEN RM W/WINDOWS 12 ' X 30 ' CONTRACTOR S � APPLICATION FEES ° SUNSTATE ALUMIUMN INC BUILDING FEE 195.00 ` � n � 1 o�`� � l� � - -.� — —� � � 1 - Ins ections Re uired • � " FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. � DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four fimes the amount of the fee imposed for the initial inspection or � first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental �entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your properly. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete.Plans,Specifications Must Accompany Application. All work shall be pertormed in accordance with , City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. , � - �� CONT CTOR SIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER -- - � I� ��f°�'/� ��` 2�- � / - ��D- �v/1�d -d d 9 l� �a-7`- .3 s lP . � �'��' �.Qt��e/ �� /��7 !/��. 2��`lts, �f. 33s-S�� /�J G� C � I�L //S �-�G � �tr�.' Si{P/I�O ( ! � - I � �� I � � � � t E 10 � � i � � �� � � , � � � ; . . ��o,�s�, � � Y GvoaO � �'J��Ic � /�/' � � ��" � �Xi,S}�r;9 5 �I ���� �' G��o����a ����� � ! � S c rerY, - �; 2a�,�.� , � , . , , 7a �.� � � � � 7, 7� i I ; � f � � i ; � /z� � � i ` � � p� - � � � , � j � a� i � � � � yv` - ---�i .�Ct'�srp/ ��Q��h /'�vCG m �� #10 SMS @ 12•' O.C. INTO EX1S71NG APPROVED SCREEN ENCLOSURE MEMBER d EXISTING APPROYED _ SCREEN ENCLOSURE MEMBEf?S. � EXlSTlNG APPROVED , SCREEN ENCLOSURE MEMBERS. ,�10 SlvlS @ l2" O.C. lNTO EXISTI NG APPROVEQ SCREEN , ENCLOSURE MEMBFR ' TYP. VFRTICAL 4 TRACK TYP. HORI�ONTAL 4 TRACK IVO FES. 1. TNlS 4UlIYDBREAK HAS BEEN DESIGIVED !N ACCORDANCE Wl7H TNE FLORIDa - BUlL.DlNG �QDE, 2004 ED1TlON . 2. THIS 'REMOVRBLE WlNDBREAK' IS AN ASSEMBLY OF SOLID VINYL AND ALUMJNUM PANELS 11VSTALLED OVER AN EXISTING AP�ROVFD SCRFFN ENCLOSllRE. 1T SHALL ONLY BE USED ON BALCONIES, PORCHES, TFRRACES, NON-HABITABLF SPACES, ETC. WHICH ARE NOT 1NTEl�IDED TO BE GLAZED OR CLOSED !!V BY WAtLS, 8UT WHFRE A WIIVDBREAK /S DESIREO. THlS W1/VDBREAK SHALL 8E REMOVED AND PROPERLY STORED AT THE 'SSUANCE OF A TROPlCAL STQRM OR HURRICANE WARNING. 3. TN1S DRAWING APPLIES ONLY TO PGT PRODUCTS. Revi3;ons Tolervnces Urtfess Nofed: �f� U QtB nofes TNElNFORWVAON, OfS�CN AF 04TA q7NfAlf�'D . --.--_. --._-- Froctions t �/64 yp�����ttbn£PRdPERTY OF PGT Pecima!,C110'f .01 proU57AEs AND cbNSrot77m COh47DtN7A[ 8) updote notes o�;mu�.ono t .aos AhID PROPRIETARY NO Aa4TlON Of�1115 Angular_ f J' pQLYIMENT AfAY BE USf'D GY2 RFPhbDUCfD IN SerieS�'°��: '�"'���' �"�°`�'���5�°`��� IRIDU�TRIE� l/ert 4T/Nor. 4T �urss7o,v aF�r rxDusm�s. Materio7: Description:.--•— — --•--- — --.i—••�_ ----- - Rcvsd By: Dote: Chkd By. �te: T . An ch o ra e fo r V4 T & SS 4 T PGT N0: YENDOR NO: Scale; Sheat Drowing No. Rev: Drorn 6y: Oa(e; �oP l 2043 O � ' • �n����r� PageNo. of Pages L! L SUN STATE ALUMINUM, INC. 6154 Fort King Rd. - _ � ZEPHYRHILLS, FL 33542 ' (813) 788-7308 . � SUBMITTEDTO P ONE � _ ' � �l�� � 1 � ��� v Q� \ ` - STREET ,�� �� � oi `�w ��. CfTY,STATE and ZIP COD JOB LOCATIO � S � �C ARCHREC OATE OF PIAN JOB PHONE _ We hereby submit speciffca8ons and estimates tor Q: � �.>C���i��t�(L�'�`� .._.. _._. .. ._._...._.___.__..------..___.__... . . ._._.._._ _ ._ . ._._ . ___. _. __...___..._ ...._____......___.__._____..._...._.__.__.__...___.__... ......__.._..._.._.__--�---�-----.._. . . � ._ . _...._ . _ .._._.... . ._ .. . . . . . . .........--�-- --._._..__._��.,._�..��_.. ..-----���--�-���`�.�t_�....._. ._.__. .._.. ._...._.-�--._. ._.__._._........._.... _. _�..��-��_...._....__c��. �-.---.__�.._`������__.`-..__�....�-_..�...._. .._.._. ... .. .__ ._..._._..__.---._._._.... ..._... .._.._. ._. ....__._..._.�..____....__....__._.. ..._.._.__._..__.____. ._.._.__....._..__._._.__._._._._._......._..____._._._._._.._... ._.---..__. .._.._...... ..._.... ..._._._..._.....-.-.---._.... .__._._._._._----.--__.._._`._..__. _..._..__._.__._.__._._. i __}._�.�_.:�_�..�__._..__�..`�.. .���..�. ��_.��s_.__._.... �� ._... .-5�-�-=-�.---. .---. .__.._...._.._.... ._....__.__.__.._.. ...__.._._ ...._.__---_..__._.__._-.------. -- � _ e� . --.--_..___._._._. ... ._. .____.._.._.._.. ._._..--.--.-..---.._..__.._-.------_.. .__..._.....__--.-.--.---.__._._._.._.._...._. ... r . _. _. . ._.._..___...._.._...__.__._.._.__..__._.._..._. .__._..__._._... ...._.._..----._..__._... ... .--.-.---_..__...._._._.-----.._._...._. ._...._.. ... ._._._...... _.___._._... ._._.._._.__._...._. ._........._._. ._._._.__._._..__._.__ .__.._..._...��_G.�,.,_.____�1�`-.45....._._�-.___.��G��___._`�_��..��. ._._._._.___._.--- -----�... .__.�..---__..._._ tA' �E QL01ttrAtt hereby to furnis , abor—complete in accordance with above specifications,for t���ym of: 1 ��� � doliars($ �� ��- ). Payment to be made as follows: All unpaid balances subject to 1.5%monthly interest fee. AO materiai is guarantesd to be as specified.Atl warfc to be campleted in a warlmianGke � manner accordirg to standard practices.My atteraHon ar deviaUon(rom sbove spedficatlons --- involvfng eMra cosLs will ba executed only upcm written orders,and will become an e i charge over and above tt�e esfimate. Ag agraements contingent upon strikes. a ' I or tlelays beyond our cordrol.Owner to carty fire,tomado snd other necessary i , te:ThiS propOSal ma�be Ou�woskers are funy mvered by Wockman's Compeiesation insucance. vv'ithdrawn b us'rf not accepted within da� �CCP.�1t�I�CCE Of C�.OTCtrI��—The above prices,speciiications and conditions a►e satisfactory and are hereby accepted. l�u are authorized Sign re to do the work as specified_ Payment will be made as outiined above. Date of Acceptance: Signature � � ' 1lliiilllliilillliiNiPiilllllif IllllliliillllNIIIIIIIIIIII ' FBC Plans 20160@3432 Fio�ida &Engineering -. .. , �uilding 62T2Abbo#StatbnDr. � . Unk101 Rcpt:17393R2 Ree: 10.00 Code ��������42 D5: 0.00 I7: 0.00 01/08/2016 E. M., Dpl.y Clerk Permil hlo. Parcel ID No NOTICE QF COMMENCEMEN7 �} Slate of �i0![��+ County ot / �S G U THE UNDERSIGNED hereby gives nolice that improvement will be made to cehain real property,and in accordance with Chapter 713,Florida Stalutes, tFe foilowing information Ss provided in this Notice oi Commencement: 1 Oescription nf Property: Parcel ldentifiCalinn No. +��I� .»(n-a� - D OOD -'0(}�0 Q � �Q�Q streetnddress: .�,�6 �Ccet�`a/ rl.t�e .� ��ulX ��l,�i�y7„�,(��'�(c ��»' .33SS"r�-- 2. General Description of Improvemenl t.� ,_q�CJ'�coryPn /'-Grl�rh l�� f//A[`/ �/h�d�t.1 S' 9. Owner Mfomretion or Lessee informalion i(the Lessee contracled for tbe impravemenl: �v G � uL ' e � �aQ�'i/���,p��I��ea,� ,�f �T�/,�3io ed tfs c%IP ,,� �5�r t Address City Slate Interest in Property;�fwJh��' Neme oT Fee Simple Tiqehalder: (ff different trom Owner iisted abovej Address �G ��� t/J._��� City Slale � 4, Cpn�reGtOr: lJ`- ,.��.k,�r ; Name G��s-y �� _ fCi�� /�� � ! � �=c 33 sY � Address ^-! q(� �}3 (� Ci�y %�' Slale � Contrectors 7elephone No. �f�� t d 6 " /3 �d ' 5. Surety: Name Address Ciry Slate Amount of Bond: S Tetephone No.: ' 6. Lender. *[ �' � Name ��►` �.� * Address City Slate `�r� s t� lentler's Telaphone No, � \ P 7 Persons within the State of Fiorida designated by the owner upon whom notices or other docoments may be served as provided by J Q Sectinn 713.13{t){a}(7),Flodda Slalules: �_` � ,� P,,, • � �♦ � � � Name � i • "" o' � � , � � r . �v � Address ' City State �q� � +��� Tetegbone Number o(Qesignated Person: ��A &, In addi0an to himsell,the owner designates o(_ `�� � �r � to recelve a copy of the Lienors Nofice as provided in Section 713.13(1){D),Ftodda Statutes. '}'� M T Telephone Nomber oi Person or Entity Oesignatetl by Owner� Q � � � 8. Earyisratipn date ot Notice ot Commencemen((the es�irdtion date may not be betore the compietion ot wnS{nutlon and fnai Rayment to the � Z � Q� � contraUor,bnt wlll be one yea�from the date of recording untess a di8ereat date Is speclfied): O � � � � J V WARNING TO OWNER: ANY PAYMENTS MApE BY THE OWNER AFTER THE EXP(RA710N OF THE NOTICE OF COMMHNCBMENT � Z � O � _! r ARE CONSIOERED lMPROPER PAYMENTS Uh'�ER CHAPTER?13, PART 1, SECTlON 713.13, F(.QRIOA S7ATU7ES, AND CAN � — U C/) O r RESULT IN YOUR PAYING TWICE fOR IMPROVEMENTS T4 YOUf2 PRqPERTY A 13t3TtGE QF' CDMMENCEMENT MU5T BE Q O � y � Cy{� 0. REGOROED RND POS7E0 pN THE JOB SI7E BEFORE THE FIRST INSPECTION. IF VOU INTEND TO OBTAIN FINANCING,CONSU4T �. (� h w WITH YOUR IENDER OR AN ATTORNEY BEFpRP COMMENCENG WpRK OR RECORDIM�YQUR N4TICE OF COMtdENCEMENT � W ~ Under penatky of pe�ury,1 dectare that i have read the foregoi�g nattce ot commencement and thet tha facts stated thereln are true to tbe best � � _ � —� � o(my knovAedge and heliel. �.. � I— Q �C Q STATE'OF FLORIDA � � � � � U couHrv oF Qasco � s ��t'i' °� S� e of Qwner o essee,or e�s or l ssee's Authorized � ~ } � W' ONcer irector/Partnerrtvlanager � Q � (� � � � d�lr�rC9E/'C� S U C.}� Sig�atory's TIt1eJOKce � � �.. � � � � V Zhe/oregoing instrumenf uas acknowledged befare me khis„��y aE�:�,20��tby,���"'�� ��L��.GL1c.,;,�� � U- W � � �1 J as �L�9.(.� � (lype of a�lhority.0.g.,o(fiter,IruSlee,BllofnEy in fOCQ COt � w 0 Q � a Z 1 (nam,e,/o(t�art�on behati ot whom insirv�,enf was ex wted}. i.R. (� � � O Personally Known O QR Prpduced IdeotiGcallon� Notary Signatur��`..J''�(„��..r�_d L /L Y�{�L�"u^'� � � � fl � ,! / . t�ff/!��Y /�- 1--��'z-�o� z T y p e o f i d e n t i f i c a t i o n P ro d u c e d��Y� L�1�- Name(Print} Ll.l � Q J � /''I�F�.�YGftrt�.b B � � �- � ,��;;�,:�Koacorro c�n f-=-,� o ;� a m {.: ;s MYCpMMiSSWNiEEt96B57 ;�• '� EXPIRES:dune28,2018 ',�,�'n.; eoroearm,t+marwt�tma� wpdatatkcslnoticecommentement_pc053Qa8 . - - Pt7VLR 5 0'NfiIL,Ph D PRSCO CLERK & COMPTRO�C£R 01UR8BK,9309m PG 311 ��� �� , ' • o�.- ^� ,, � ,:,:_ �, �_ � - � i� >>. /' City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: �Z,�.��5�� ��it�(.!�'t� �/1(� ��'l ' Date Received: � � Z�� l b ' Site: c� Z�°3� �i�-G<-�,� '�GL .(� ' ,� / �,{ � Permit Type: �`�� ���-'� `U S(.{�►'1 t�'�j?�'' 1 Z� �1! � Approved w/no comments. Approved w/the below comments: ❑ Denied w/the below comments: ❑ ' ' � f � ` _ I Y � d E This comment sheet sha11 be kept with the permit and/or plans. �� � � i ���� Kal�in Switz�� Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) i i s�3-7so-oo20 , i City of Zephyrhills Permit Application _ _ _ -_ _ FaX-s�s-7so-oo2� ' � '� ' • Building Department � ' � � � ,.�^ , , - ' „ Date Received �-!,� i ' - p _ / Phone Contact for Permittin � o - _,7 3/ .� , TrITI-IT� � - --- �/'�' / ' .__ _ ,._. - i Owner's Name C 'r�- /`j[.LG � (/`-fNe S�P{� Owner Phone Number 5`�!3-�5' - /+ / Scct�tsJol�I�4 2. J S�s'1 ' Owner's Address � (.G 6tG,C S'TC �3/ Owner Phone Number Fee Simple Titleholder Name � Owner Phone Number I ' Fee Simple Titleholder Address , JOBADDRESS �a 0 ��GC/"e� �/a `� ���� �S -�C• 33 sy2- LOT# �� � SUBDIVISION � �%C ua-( PARCEL ID#�y'��o"�� -�DO�-��ad- Q°9 � � ! (OBTAINED FROM PROPERTY TAX NOTICE)' WORK PROPOSED e , NEW CONSTR B ADD/ALT 0 SIGN Q Q DEMOLISH INSTALL REPAIR PROPOSED USE Q SFR Q COMM 0 OTHER TYPE OF CONSTRUCTION Q IBLOCK Q FRAME � STEEL 0 DESCRIPTION OF WORK �DI W'�c 1� l` v�'i�'�L��'1 Yh � I�l k�! � w/K�d!� BUILDING SIZE �X 3 v I SQ FOOTAGE �� U HEIGHT �TTI"IT�TTrtTI'TI�TIT1�1T1�TI�ITrITT1Tt�1�ITTT�IT1�Tf TTP'TI�TI�T1� �BUILDING �1q pQO.d D VALUATION OF TOTAL CONSTRUCTION y�, � � t G✓ '�ELECTRICAL $ � AMP SERVICE 0 PROGRESS ENERGY Q W.R.E.C. QPLUMBING $ � � / � GLY i OMECHANICAL $ VALUATION OF MECHANICAL INSTALLATION � QGAS Q ROOFING Q SPECIALTY 0 OTHER � FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA �YES NO (� 2�-j�. -1-i-1--F-1--1--f-I{-1-1-4-�1--I-1-1-f-i�-1-1-1-/-I-I-1--1--I-I-1-1--E�-i-f-1-f-I-1-{--F-�1-H-1-1--1-I--1-1-F-1-1-I-i-1-F-a-E--1-1-f-i-1-E-1-f-i-i-E- ' BUILDER � ' � ��OMPANY LllfS �Y�P �4!!�f/YIUk^ SIGNATURE I � REGISTERE� Y/ N FEE CURREN Y/N Address c�l��/ ��•�G�7y � �lti`�S' �-� �3Sy y License# �Q�i2 0�� � ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address I License# � • PLUMBER I COMPANY I SIGNATURE I REGISTERED Y/ N FEE CURREN Y/N Address I License# � MECHANICAL � COMPANY I SIGNATURE I REGISTERED Y/ N FEE CURREN .Y/N I Address I License# OTHER l COMPANY SIGNATURE I REGISTERED Y/ N FEE CURREN Y/N Address I License# 1111111111111111111 �111111 '111111111111111111111111111111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2y sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten.(10)working days after submittal date. Required onsite,Construction Pians,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 d�mpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. **"'PROPERTY SURVEY required for all NEW construction. -�-*-1-i-I-�--4-I--1-�4-t-t..{..i-f--1-1-i t-(..t-1..{-1-I-1-L-t-t-{..4.i-{�i-{-1-�-{.�1-1-{..1-{..f-i-f-i�-I-{�{-1-f�-f-i-f-f�1-��-1-f..4.foi.�1-{� Dlrections: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commenci ment is required. (AfC upgrades over$7500) •* Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs if shingles Sewers Seiice Upgrades A/C Fences(PlotlSutvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW I � i � r I -- I ( I � I NOTICE PJF DEED RESTRICTI�ONS: The under.signed understands that this permit may be subject to"deed"restrictions" which may be more resfrictive fhan County reguiations. The undersigned assumes respansibiiity for compliance with any applicable deed restric#ions. UNL(CElUS�D CONTRACTQRS AND COIVTRACTOR RESPOIVSlB1LlTlES: !f the owner has hired.a contractor or contractors to undertake work, �hey may be required to be licensed in accordance with state and local regulations. If fhe ; ; contracfar is nof Iicensed as re�quired by law, bath the owner and contractor may be cited for a misdemeanor violation i under state iaw. if the owner or intended contractar are uncertain as to what licensing requ'sremen#s may apply for the � f Entended wark,fihey are advised to contact tha Pasco County Buifding lrtspectian Division—Licensing Section at 727-847- ', 8049. Furthermore, if the owner has hired a contrac#or or contractors, he is advised to have the cantractar(s) sign � ; portions af the "co�rtractor Block" of this application for which they will be responsible. If you, as the owner sign as fhe ' confracfor, fhat may be an indication thaf he is not properiy iicer�sed and is not entifile�d to permitting privileges in Pasco ' County. - TRANSPC?RTATlON lMPACT/UTlLlTlES lMPACT AND RESC?URCE REC4VERY EEF�: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buitdings, change of use in exisfing buiidings, or expansion of existing buiidings, as specified in Pasco County �rdinance number 89-07 and 90-07, as amended. The undersigned also unders#ands, fhat such feas, as may be due, wil! be identifed at the time of perrrtitting. It is further underst�ood that Transpartation lmpact Fees and Resource Recavery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not invalve a certiflcate of occupancy or final power refease, the fees musfi be paid prior fo permit issuance. Furthermore, if Pasco County WaterlSewer Impact fees are due,they must be paid priar to permit issuance in accordance with appficabie Pasco County ordinances. CONSTRUCTIC?N LlEN LAW(Chapter 713,F{orida Statutes, as amended}: lf vaJuatian af wark is$2,500.00 ar mare, ! certify that !, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide° prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", (certify that i have o6tained a copy of the above described dacurrtent and promise in good faifh to deiiver it to the"owner"prior to,commencement. Ct?NTRACTt}R'S/QWNER'S AFFtqAVlT: i certify that all the information in this app{ication is accurate and that a!I work will be dane in compliance with a!! applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installafion as indicated. i certify fihat no work or insfaitation has commenced prior #o issuance af a permit and that a11 wark wi11 be performed ta rrreet sfandards of a11 faws regulating canstruction, County and City cadas, zaning regulatians, .and land development regulations in the jurisdiction. 1 also � cer#ify that 1 understand that.the regulations.of o#her government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include buf are nofi iimited fo: - Depar#ment of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmenfaiiy Sensitive Lands,WaterlWas�ewater Treatment. - Sauthwest Florida Water Management Dis#rict-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps af Engineers-Seawalls, Docks, Navigable Waterways. - �Department .af Health & Rehabilitative Services/Enviranmental Health Unit-1Ne1(s, Vl/astewater Treatment, Sepfic Tanks. - US Environmenta! Protection Agency-Asbestos abatement. Federal Aviation Au#hority-Runways. I undersfiand that the following�restrictions apply to the use of fi1l: - Use afft(i is not aliowed in Fioad�Zone"V"uniess expressiy permitted. - If the fi(I materiaif is to be used in Flood Zone "A", i# is understood that a drainage plan addressing a "campensating volume" wi!! be submitted at time of permitting which is prepared by a professianal engineer licensed by the 5tate of Florida. - If the fi11 material is to be used in �1oad Zone "An in connection with a permitted building using stem wa11 construction, 1 ce ify that�ll wi11 be used anly to fl1 the area within the stem wa!(. - !f fill materiaf is to be used in any area, 1 certify that use af such �ll wi!! not adversely affect adjacent praperties. !f use�of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of he building permit issued under the attached permit application, for iofs less than ane (1) acre which are eievated by fiii, an engineered drainage plan is required. ; 1f i am the AGENT FC}R THE�ODUNER, i prarr►ise iri good faith to inform the owner of the permitting conditions sst forth in i this a�davit prior fio commencing construction. ! understand that a separate permit may be required for electrical wark, plumbing, signs, wells, pools, air conditianing, gas, or ofiher installations not specifically inciuded in the application. A permif issued shall be construed to be a (icense to proceed wifh the work and not as authority to vioiate, canceS, aiter, or set aside any pr.ovisions of the technicai codes, nor shali issuance of a permit pr�vent the Buiiding Officiaf from thereafter requiring a correctian af errors in pians, canstructian or vialations of any codes. �very permit issued sha!!become invalid unless the work authorized by such permit is commenced within six manths of permit issuance, or if work authorized by � the permit is suspended or ab'andonetl for a period of six(6) months af�er the time the work is commenced. An extension may be requested, in writmg,�from the Suiiding Officiai for a periad nofi to exceed ninety (90) days and will demonstrate jusfifiable cacase for the extens�on. Cf work ceases for ninety{90}consecutive days,the job is considered abandaned. E ' WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPRO�VEMENTS TO YCIUR PROPERTY. IF YOU INTEND T'O't�BTA1N FINANC1iVG,CONSt1L3' WtTH YtJUR LENDER UR AN AT7'ORNEY BEFORE RECORDtNG YOUR�t�TICE OF CONfMENCEfVIENT. Fi.OR1DA JURAT{F.B.117.03 � f t OWNER CiR AGENT I l, f " .,�cn CONTRACTQR .._ f��_� S bscribed and swom qr�affirm d� e ore me fhis J Sub crib dand swom to o rr�e,d befQ� ine this ! I o2. I ir by d'h J / 02 ! {, by �,�Q.tif''h c-� 1f�t t�z �_ a�stare personalSy kn, awn t me or hasthave praduced o is/are persona!!y known to me or�raslhave produced as identification. as identification. i I � I i /y /''�� �� �Natary Public ,tt/�it.,(ri�''k'' `-al" ��ll . Natary Public � � t Commissian No. �!" ����pi)� Commission No. �"����o � . Nam o�„�iv���tvpedd+�A�IGYSJ m�R000{S Name of t�tefa;.,pr�e�-�+�ia€�t.orst��;m 5RC3 _--- :2 �_. °'°t�,,�,`°-''� NANCY J �Rt3Ci�CS ' �`� `• MY COMMISSION#FF093699 `; °�= . '` 11AY COMMISSIOR}#FFQ93699 •�Nl. � i �9y�offloP'� EXPIRES Febru�ry 18.2018 �:"^v'�o";� ''-..,,'L�o�,�:oPr EXPIRES FLbruBEy y$,201$ (ao�)3s8-o153 FloridallotaryService.com (40�y 398-0153 FloridallotaryService.com _ . , . I ' I HEREBY CERTIFY THAT I HAVE REVIEWED PRODUCT APPROVAL CODE CHART THIS PLAN AND FOUND IT TO BE IN JOIST I SPAN (W) I GIRDER SPAN (S) STRUCTURAL COMPONENTS COMPLIANCE WITH ASCE 7-10&FBC STH = I I r I SIMPSON ABA OR ABU POST BASES - FL10849.6 EDITION(2014)RESIDENTIAL&EXISTING I PT 2x6 I 9' MAX I(2) PT 2X6 I 8' MAX I SIMPSON AC, LPC OR LCE POST CAPS - FL10860 SIMPSON H5 CLIP- FL10456 N 8'-0" MAX PT 2x8 12' MAX (2) PT 2X8 I 10' MAX I SIMPSON LULUS JOIST HANG - FL10655 2X6 GIRDERS 2 PT 2x10 14' MAX PT 2X10 12' MAX SIMPSON LUC JOIST HANGERS- FL11169 SEE SPAN CHART FREESTANDING DECK - DO NOT ATTACH JOISTS TO EXISTING HOME ALL CONNECTORS AND FASTENERS IN CONTACT W/TREATED WOOD SHALL BE ZINC COATED =j DECK MAY BE CONSTRUCTED WITH GALVANIZED STEEL OR SIMPSON 'ZMAX' H GIRDERS RUNNING PARALLEL OR FASTEN FLOOR JOISTS TO DBL. 0 O 2X6 GIRDERS W/SIMPSON H5 16" a PERPENDICULAR TO EXISTING HOME - bI FO /+ ® Nz O A 1r DBL 2X6 N 0< 0 PERIMETER JOISTS Pt o' I a 0 NW COMPOSITE DECK PLANKING CO FASTENED W/#1OX2" x x SCREWS 2 PER BOARD ® 0 PROFESSIONAL ENGINEER SEAL EVERY JOIST FASTEN FLOOR JOISTS TO DBL. ENGINEER OF RECORD: 2X6 PERIMETER JOISTS FASTEN WOOD DECK W/SIMPSON LUS HANGERS OR BOARDS W/Bd V. NAILS, 0 EQUIV David W. Smith P.E. 2 PER BOARD 0 EVERYFASTEN FLOOR JOISTS TO GIRDERS JOIST 30'-0" P.T. DBL. 2X GIRDER FLORIDA LICENSE NUMBER:53608 FLORIDA H5 TYPICAL FLOOR JOIST/GIRDER LAYOUT Thomas L. Hanson P.E. . Mark Ronald Dunn, Jr. P.E. FLORIDA LICENSE NUMBER:38654 12 2X JOISTS J OPT I PERIMETER JOISTS FLORIDA LICENSE NUMBER:73968 ' ALUM. TERMITE SHIELD -- - __ @ EACH PIER Joel Falardeau P.E. II ORIABSIPAD CONCRETE PAD, FLORIDA LICENSE NUMBER:70667 1__L .1__L_ 1--r �--T- AUGER ANCHORS ® 8'-0" O.C. MAX. SECURE WITH ASTM #123-89A FBC Plans & Engineering STRAP OR EQUIV. OVER GIRDER Services, Inc. 32" IMBEDMENT 6272 Abbott Station Drive Unit 101 PT (3) 2x12 AIR STRINGERS Zephyrhills,fl.33542 PLAN VIEW BLOCK PIER AND ANCHORS Phone:(813)788-5314 Fax:1-(866)-824-7894 email:erb@fbcplans.com Website:www.fbcplans.com C.O.A.-#29054 DRAWN BY: W.P. PICKETS SHALL NOT ALLOW A 4"0 SPHERE TO PASS. DATE: 01/12/16 TRIANGULAR OPNG. SHALL z 4PRE-MANUF. REVISION: DATE: NOT ALLOW A 6"0 SPHERE TO PASS. 2X2 ALUM. HANDRAIL RO 1 POST n M PER FBC 311.7.8 - 4 OR MORE RISERS REQUIRES A HANDRAIL. I RO 2 PO MAX.-PT 2X TREADS. FASTEN TO STRINGERS W/(4) 16d NAILS EA. CONNECTION RO3 PT DBL 2X PERIMETER PICKETS SHALL NOT ALLOW A JOISTS ATTACHED RISER HEIGHT = 7 3/4" MAX. 4"0 SPHERE TO PASS. RO4 TO PT 4X4 POSTS HEIGHT DIFFERENCE BETWEEN RISERS SHALL NOTz TOP/BOTTOM RAILS TO POSTS W/ W/(2) 3/8"0 STEEL BOLTS EXCEED J" 1 1/2"xt 1/2" x3/16" ANGLE PROJECT ADDRESS: TREAD DEPTH = 10" MIN. (NOT INCLUDING NOSING) W/ (2) EA FLANGE #10x3/4" TEKS A NOSING NOT LESS THAN J" & NOT MORE THAN 1}" SHALL BE PROVIDED ON STAIRWAYS WITH SOLID RISERS. GENE SHELLY EXCEPTION: A NOSING IS NOT REQUIRED WHERE THE TREAD 3828 LAURELL VALLEY DEPTH IS A MINIMUM OF 11" ZEPHYRHILLS, FL 16"X16" ABS PADS UNDER STRINGERS P 2"xPERIMETER JOIST WELD OR 4" 2500 PSI CONCRETE PAD BASE. ATTACH PER MANUF. CONTRACTOR: PT (3) 2x12 STAIR STRINGERS SPECS. OR (4) J"OX22" FASTEN TO DBL 2X PERIMETER JOIST LAG SCREWS FOR WOOD SUN STATE ALUMINUM, INC. W/SIMPSON #LU210 OR EQUIV. PER DECKS MFGRS SPECIFICATIONS WOOD STEPS & ALUMINUM HANDRAIL ALUMINUM POST & RAILING TO DECK CONNECTION WOOD DECK *REAKF .FLASHING INSTALLED UNDER EDGE 3"X 48024"116. I HEREBY CERTIFY THAT I HAVE REVIEWED EDGE ON FIRST ROW OF SHINGLES BEAM IS FOAM DENSITY TH IS PLAN AND FOUND IT TO BE W THE SIZE AS UPRIGHT COMPOSITE ROOF COMPLIANCE WITH ASCE 7-10&FBC ST VINGC ANNEL OR 3"X4B"COMPOSITE #10 X 4"SMS 1-1/4" PANEL EDITION(2014)RESIDENTIAL&EXIVING CHANNEL #10X4"SMS ROOFPANEL NEOPRENE WASHER SMS1-1/4"NEOPRENE 8"O.C.PER PANEL.C.FOR COMPOSITE PANEL WASHERO.C.PERPANEL - - - SOLIDROOF12"OPEN BACKATTACHED 2X3 PATIO BEAM/ COMPOSITE PANEL TO POST w/(2) (3)3/8"(MI #10x1)5"SMS&TO EDGE BEAM w/ II II == THRU BOLTS G l #10 X I Y"SMS 1r o.C. I I I I WASHERS/NUTS J HEADS X R CHANNELT I ASCIA. H CONNECTING I I I I SCREW BOSS �� HEADER OR CHANNEL TO FASCIA II I I MAY NOTCH FOR CENTER II II OR EDGE OF POST 2"X6"SMB BEAM II II FASTEN 1X2 TO EXIST.WALL FRAMING ii I ASTEX2}"LAG SCREWS 5"FROM TOP& I I I 2X3 PATIO UPRIGHT POST OR UPRIGHT PROFESSIONAL ENGINEER SEAL BOTTOM&24°O.C. I I I I UPRIGHT II II (SEE PLAN FOR SIZE) ENGINEER OF RECORD: ROOF PANEL TO EDGE BEAM CONNECTION DETAIL David W. Smith P.E. ROOF PANEL TO FASCIA/HOST BEAM CONNECTION DETAILS SCALE:NTS ROOF PANEL TO EDGE BEAM CONNECTION DETAIL FLORIDA LICENSE NUMBER:53608 PATIO COVER (3)#12 X 3/4"SMS FASTENING Thomas L. Hanson P.E. SECONDARY NOTE:MINIMUM EMBEDMENT OF (1)-1/2"0 LOT CONCRETE FLORIDA LICENSE NUMBER:38654 ANGLE TO COLUMN(TYP EACH SIDE) COLUMN SCREW WITH 2-3/4" ANCHORS INTO CONCRETE FOOTING SHALL SECONDARY ANGLE(MIN EMBEDMENT(MIN EDGE BE 2-3/4"AT ALL POST LOCATIONS.ALL 0.125"THICK) DISTANCE=3"J "\ --- SCREW LENGTHS AT POST CONNECTIONS _- _ (B)-3/8"0 X 2"MIN EMBEDMENT LAG SCREW (NOT REQUIRED WHEN PER OUTER FLANGE "1 ' P I SHALL BE OF SUFFICIENT LENGTH FOR Mark Ronald Dunn, Jr. P.E. INTO SECONDARY ANGLE(TYP EACH B=0 IN THE �S\� REQUIRED EMBEDMENT INTO CONCRETE SIDE)(SEE TABLE BELOW FOR QUANTITY) TABLE BELOW) FOOTING WHEN A PAVER DECK IS PRESENT. FASTEN 1X2X.044"TO ALUM.UPRIGHT FLORIDA LICENSE NUMBER:73968 W/#12X1}"SMS WITHIN 3"FROM ENDS&@ 0 PRIMARY 2"X 2"X 0.125"ANGLE O (2)-3/B"0 MACHINE 120G. DECKING O (3)#12 X 3/4"SMS BOLTS WITH WASHERS TOP VIEW FASTENING COLUMN OR(4)#14X3/4"SMS ALUM.SQUARE COLUMN • 1"X2"OPEN BACK Joel Falardeau P.E. TO PRIMARY ANGLE(TYP EA.SIDE EACH SIDE) FLORIDA LICENSE NUMBER:70667 2"SPACING 1"X 2"BASE MEMBER (MIN)(TYP) (1)-1/2'•0 LOT CONCRETE (TYP EACH SIDE) SCREW WITH 2-3/4" 11 GA,INTERNAL ALUM,BASE,PREDRILL VERT.FLANGES EMBEDMENT(MIN EDGE TABLE 3/8"ØX2"MIN.EMBEDMENT DISTANCE=3") (4)3/8"CONCRETE SCREWS(INTERNAL) ALUM.POST PER PLAN FBC Plans &Engineering LAG SCREW INTO PER OUTER FLANGE W/2-3/4"EMBEDMENT,3"MIN.EDGE DISTANCE Services, Inc. PRIMARY ANGLE AND @ 24" Column B FLOOR OIST 6272 Abbott Station Drive Unit 101 J O.C.BETWEEN COLUMNS(TYP Size EACH SIDE) Zephyrhills,8.33542 PERIMETER STRINGERS .c d - 1"X2"OPEN BACK 3x3 0 4 " d. �— Phone:(813)788-5314 2x3 0 NOTES: '"p: v d ____ Fax:1-(866)-824-7894 2x4 1 1,NUMBER OF LAG SCREWS IS EACH SIDE AND DOES NOT INCLUDE THE (2)#10x14/2'SMS MIN Website:www.fbcplans.com 2x5 1 LAG SCREW INTO THE 1X2, THRU SCREW BOSS OF 3.LAG SCREW DESIGNS ARE BASED ON AN ALLOWABLE WITHDRAWAL 1"X2"OPEN BACK 2x6 2 LOAD OF 450 LB.AND AN ALLOWABLE LATERAL LOAD OF 240 LB.FOR NOTE:CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON TITEN HD 1/2"0 SCREW 2x7 2 WOOD WITH SPECIFIC GRAVITY,G=0.55. ANCHORS,OTHER SIZE OR TYPE OF ANCHORS SHALL NOT BE USED. DRAWN BY; 2X8,2x9,2X10 3 4.ALL LAG SCREWS SHALL BE FULLY INSTALLED INTO PERIMETER STRINGERS OR FLOOR JOISTS FOR THE ENTIRE LENGTH OF THE SCREW. 3X3 POST CONNECTION DETAIL OPEN BACK TO ALUMINUM POST DETAIL DATE: 01/12/16 2"x 3"OR LARGER POST OR SMB TO WOOD DECK DETAILS REVISION: DATE: RO 1 EDGE BEAM PER PLAN RO 2 RO 3 2X3 ALUM,ABOVE RO 4 WINDOWS i I OPTION#1 I I 2)(3 ALUM.UP HT l, PROJECT ADDRESS: I (4)#10x1]2"SMS DOOR INTO SCREW BOSSES GENE SHELLY ACRYLIC OR VINYL INSERTS ------ ------- 3828 LAURELL VALLEY YLI SHALL BE REMOVED WHEN WIND SPEED I I IS EXPECTED TO EXCEED 75 MPH.3 SEC GUST X 0 ZEPHYRHILLS, FL 2"X2"OR 2"X3" I 0.062"ALUMINUM INTERNAL HORIZ.1SUDER MEMBER I OR EXTERNAL RECEIVING MANUFACTURERS CHANNEL W/(4)#10 X 3/4" CONTRACTOR: INSTRUCTIONS I INTO INTO BEAM OR UPRIGHT.(2)#12X 3/4"EA. 22 CA.KICKPLATE INSTALLED W/ LEG INTO GIRT OR PURLIN- SUN STATE ALUMINUM, INC. #10/3/4"@12"O.C. -••••• ••v,' I I #12x3/4"SMS EA LEG0062 ANGLE CLIPS) UPRIGHT UPRIGHT OR BEAM-SNAP DOORS&WINDOWS ATTACHED PER MFG.SPECIFICATIONS HOLFMATING OR HOLLO W SCREEN ROOM CHAIR RAIL CONNECTION ALUM.DETAILS I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUNDIT TO BE IN COMPLIANCE WITH ASCE 7-10&FBC 5TH EDITION(2014)RESIDENTIAL&EXISTING 3"X.024 COMPOSITE ROOF VINYL PANELS-FL 7561-R3 OR EQUAL WINDOWS-TYP. C 2X6 SMB r� � X M X M M M X X M N N N N lXy N O PROFESSIONAL ENGINEER SEAL CO ' M 2X2 2X2 ENGINEER OF RECORD: x ________rn David W. Smith P.E. ch 1X2 KICKPLATE 1X2 1X2 FLORIDA LICENSE NUMBER:53608 ≤h N Thomas L. Hanson P.E. 4"CONC. PATIO 4'-376" 4'-376" 4'-3716" 4'-37/16" 4'-376" 4'-338' ANDWOOSTD DEPSK FLORIDA LICENSE NUMBER:38654 12' 30' AUGER ANCHORS Mark Ronald Dunn,Jr. P.E. @ EA. PIER FLORIDA LICENSE NUMBER:73968 NOTE: REAR ELEVATION VINYL WINDOWS SHALL BE REMOVED Joel Falardeau P.E. WHEN WINDS ARE PREDICTED TO BE 3/16"=1'-0" 28' FLORIDA LICENSE NUMBER:70667 75 MPH OR MORE. 3"X.024 COMPOSITE ROOF 3"X.024 COMPOSITE ROOF FBC Plans &Engineering PANELS-FL 7561-R3 OR EQUAL PANELS-FL 7561-R3 OR EQUAL Services, Inc. 6272 Abbott Station Drive Unit 101 Zephyrhills,fl.33542 2X3 Phone:(813)788-5314 Crj Fax:1-(866)-824-7894 C', (h PARK N N X N X Website:www.fbcplans.com MODEL N N PARK o MODEL o DRAWN BY: JL r 2X2 ' DATE: 01/12/16 KICKPLATE II 1X2 1 KICKPLATE REVISION: DATE: WOOD DECK RO 1 RO2 F _____ _______ _______ - I RO 3 UGER ANCHORS UGER ANCHORS RO 4 3'-2" 4'-5" 4'-5" @ EA. PIER • 4'-6" 3' 4'-6" @ EA. PIER PROJECT ADDRESS: 12' 12' GENE SHELLY LEFT SIDE ELEVATION RIGHT SIDE ELEVATION 3828 LAURELL VALLEY ZEPHYRHILLS, FL, 3/16"=1 '-0" 3/16"=1'-0" CONTRACTOR: SUN STATE ALUMINUM, INC. PLANS &ELEV. I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN COMPLIANCE WITH ASCE 7-10&FBC 5TH EDITION(2014)RESIDENTIAL&EXISTING 36' PROFESSIONAL ENGINEER SEAL ENGINEER OF RECORD: David W. Smith P.E. `r FLORIDA LICENSE NUMBER:53608 2015 PARK MODEL Thomas L. Hanson P.E. FLORIDA LICENSE NUMBER:38654 -►-' Mark Ronald Dunn, Jr. P.E. FLORIDA LICENSE NUMBER:73968 - - - � MFG. HOST BEAM to 2X6 SMB 2X3 2X3 Joel Falardeau P.E. C') X ( c4 FLORIDA LICENSE NUMBER:70667 N X X19 2X3 PROPOSED SCREEN ROOM 2X3 FBC Plans & Engineering PROPOSED W/VINYL WINDOWS ON WOOD Services, Inc. DECK 6272 Abbott Station Drive Unit 101 COVERED c' Zephyrhills,fl.33542 PATIO Phone:(813)788-5314 2X3 2X3 Fax:1-(866)-824-7894 Q9p ch Website:www.fbcplans.com N N X X DRAWN BY: JL + 2X6 SMB 2X3 N 2X3 N N 2X3 N N 2X3 2X3 DATE: 01/12/16 REVISION: DATE: 3"X.024 COMPOSITE ROOF RO 1 PANELS-FL 7561-R3 OR EQUAL 4'-33/S' 4'-37%6" 4'-37A&' 4'-3716" 4'-37i46" 4'-37%6" 4'-37/46" RO 2 RO3 12' 30' RO4 PROJECT ADDRESS: PLAN V VIEW GENE SHELLY f 1-011 3828 LAURELL VALLEY 3116i ZEPHYRHILLS, FL CONTRACTOR: SUN STATE ALUMINUM, INC. PLANS &ELEV. General Notes HOT DIPPED GALVANIZED. I HEREBY CERTIFY THAT I HAVE REVIEWED A.CONCRETE&FOUNDATION DESIGN: S.ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X 4. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY THIS PLAN AND FOUND IT To BE IN BOLT DIAMETER INTO STRUCTURAL FRAMING(G=.42 MIN.). CONTRACTOR. COMPLIANCE WITH ASCE 7-10&FBC 5TH 1. ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE 5. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL EDITION(2014)RESIDENTIAL&EXISTING PSI MINIMUM. PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF ENSURE BONDING AGENT IS USED FIRST. MINIMUM,3 1/2"NOMINAL THICKNESS. THE BOLT OR SCREW.ALL LAG BOLTS AND SCREWS SHALL BE 6. SCREENING MATERIAL SHALL BE 18X14X0.013 OR 3. 3000 PSI FIBERMESH(3/4"PER CUBIC YARD MIN.)MEETING INSERTED IN PILOT HOLES BY TURNING AND UNDER NO EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED CIRCUMSTANCES BY DRIVING WITH A HAMMER. OTHERWISE. IN LIEU OF WELDED WIRE MESH 7.ALL EXPANSION ANCHORS SHALL BE DESIGNED IN 4. ALL SLABS ON GRADE SHALL BE 4"THICK WITH FIBERMESH. ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S 5. ALL REINFORCING SHALL CONFORM TO ASTM A615,BE GRADE REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY 60(60 KSI MIN.)DEFORMED BARS,#3 BARS MAY BE GRADE 40 BE APPLIED IN CONDITIONS ACCEPTABLE TO 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL MANUFACTURER. FASTENERS SHALL BE A MINIMUM OF SAE SCREEN ROOM,PATIO COVER&WOOD DECK BE 3000 PSI MIN.,2"MINIMUM.THICKNESS. GRADE#5 OR BETTER ZINC PLATED. 7. SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF. B.ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR 8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 FOLLOWING: 18-8,UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES OPC(PORTLAND CEMENT TYPE 1,-ASTM C 150). FOR USE WITH ACQ PRESSURE TREATED WOOD,OR DESIGN DATA: AGGREGATES-#6 STONE,ASTM C 33 SIZE NO.67 LESS THAN OTHERWISE NOTED ON PLANS. 1. ULTIMATE DESIGN WIND SPEED Vult,(3 SECOND GUST): 130 MPH 3/4". 9.ALL FASTENERS SHALL COMPLY WITH ASTM A153. NOMINAL DESIGN WIND SPEED Vasd: 110 MPH AIR ENTRAINING+/-1%-ASTM C 260. 10.ALL CONNECTORS SHALL COMPLY WITH ASTM A653 CLASS 2. RISK CATEGORY: I PROFESSIONAL ENGINEER SEAL WATER REDUCING AGENT-ASTM C 494. G-185. 3. WIND EXPOSURE: B CLEAN POTABLE WATER. 11.FOR SMS,THE MINIMUM CENTER-TO-CENTER SPACING SHALL 4. WIND LOADS: ENGINEER OF RECORD: OTHER ADMIXTURES SHALL NOT BE PERMITTED. BE 3/4"AND MINIMUM CENTER-TO-EDGE SHALL BE 1/2" (MWFRS): 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. UNLESS NOTED OTHER WISE. SOLID ( ): 23 PSF 10.PREPARE&PLACE CONCRETE ACCORDING TO AMERICAN i David W. Smith P.E. CONCRETE INSTITUTE MANUAL STANDARD PRACTICE,PART 1, E.REFERENCE STANDARDS: COMPONENT&CLADDING PRESSURES: FLORIDA LICENSE NUMBER:53608 2,&3 ALONG WITH HOT WEATHER CONDITIONS ASTM E 119 ROOF ZONE 1: 8.9/-21.8 PSF, ZONE 3: 8.9/-55.0 PSF RECOMMENDATIONS. ASTM E 1300 WALLS: ZONE 4 21.8/-23.6 PSF, ZONES: 21.8/-29.10 PSF 11.IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, ASCE 7-10 CONCRETE SHALL BE A MINIMUM OF 4"IN THICKNESS, AA S ASM35,AND SPEC.FOR ALUMINUM PART 1-A,&1-B 5. WOOD DECK FRAMING,SEE ENGINEERING Thomas L. Hanson P.E. VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, ASTM C94 SPALLING OR OTHER DETERIORATION. ASTM C940 FLORIDA LICENSE NUMBER:38654 6. SCREEN ROOF TYPE: ASTM C33 B. MASONRY: 7. SOLID ROOF TYPE: COMP.PANEL ROOF,FL 2291-RB OR EQ. ASTM C494 1.CONCRETE MASONRY UNITS(CMU)SHALL BE STANDARD ASTM C494 Mark Ronald Dunn,Jr. P.E. HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON ASTM A615 TYPE FLORIDA LICENSE NUMBER:73968 M OR S MORTAR. ASTM A185 2.ALL MORTAR SHALL BE OF TYPE M OR S. FLORIDA BUILDING CODE 2014 (CHAPTERS 16,20 AND 23) 3.ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE 5TH EDITION MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 2010 ALUMINUM DESIGN MANUAL 4.PROVIDE CLEAN-OUTS FOR REINFORCED CELLS CONTAINING Joel Falardeau P.E. REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0"IN F.ABBREVIATIONS: FLORIDA LICENSE NUMBER:70667 HEIGHT. THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT ALL THOSE USED ON THESE DRAWINGS,BUT C.ALUMINUM: TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. FBC Plans &Engineering 1. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE 1. TYP--TYPICAL g g 2. SIM--SIMILAR ALUMINUM STRUCTURAL MEMBERS MINIMUM REQUIREMENTS OF 6005-TS FOR ALLOY WITH A 3. UON--UNLESS OTHERWISE NOTED Services, Inc. MINIMUM THICKNESS OF 0.040"FOR SUPPORTING MEMBERS. 4.CONT--CONTINUOUS HOLLOW SECTIONS 6272 Abbott Station Drive Unit 101 2. WHERE KICKPAT ARE USED A MINIMUM THICKNESS OF Zephyrhills,fl.33542 0.024"SHALL APPLY. 5.VIF--VERIFY IN FIELD 2x2:---------------------------------------2"x 2"x 0.044" 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO"PART 1-A- G. RESPONSIBILITY: 3 x 2:---------------------------------------3"x 2"x 0.050" Phone:(813)788-5314 SPECIFICATIONS FOR ALUMINUM STRUCTURES-ALLOWABLE SED 2 x 3:---------------------------------------2"x 3"x 0.050" Fax:1-(866)-824-7894 STRESS DESIGN"OR"PART 1-B-SPECIFICATIONS FOR 1.ALL TRASITE WORK SHALL DE NCEWITH PERFORMED BY IA ALIBLE BUILDING ALUMINUM STRUCTURES-BUILDING LOAD AND RESISTANCE CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING 2 x 3:---------------------------------------2"x 3"x 0.070" Website:www.fbcplans.com CODES,LOCAL ORDINANCES,ETC. 2 x 4: FACTOR DESIGN"OF THE ALUMINUM DESIGN MANUAL 2010 2"x 4"x 0.050" 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, 2 x 5:---------------------------------------2"x 5"x 0.050" PREPARED BY THE ALUMINUM ASSOCIATION, NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWN BY: INC.WASHINGTON D.C.THE 2014 FLORIDA BUILDING CODE 5TH DRAWINGS,FABRICATED ITEMS,OR ACTUAL FIELD A r EDITION(CHAPTER 16 STRUCTURAL DESIGN&CHAPTER 20 CONDITIONS. OPEN BACK SECTIONS < / ') DATE: 01/12/16 ALUMINUM). 3.THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE2:----------------------------------------1"xpp 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL,OR 1 x 2"x0.040" SUNROOM'ROOM ADDITION ELEMENTS AS PROVIDED BY THE PRESSURE TREATED LUMBER PROVIDE DIELECTRIC 1 x 3: 1""x 3"x 0.045" d� REVISION: DATE: CONTRACTOR. 7 I( ESEPARATION. L T ALL DETAILS ONTHESE DRAWINGSARE ENGINEERED 5. ALUMINUM#1 SMS 6MB RS SHALL BE THE ENDS AND 12"ON CENTER,IF S 4.ON INFORMATION PROVIDED BY THE CONTRACTOR AND BASED SNAP SECTIONS Cf�YOF�/ r{ t fJ/�� r RO 1 MANUFACTURER. 2 x 2 Snd 2"x 2"x 0.045" f l�Ii ?tT F 7Z�f 0 2 6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE.THEY USING#12 SPACING MAY BE 24"ON CENTER. S.ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A 2 x 3 Snap:p 2"x 3"x 0.050" l L���/ r,l,r,. � LICENSED P.E.IN ACCORDANCE WITH STANDARD ( / t? y 0 3 REMOVABLE PANEL ALL BE SHALL BWITH A E REMOVED WHEN WIND ECAL ESSENTIALLY TING ENGINEERING PRACTICES. 2 x 4 Snap: 2"x 4"x 0.045" �) � SPEEDS EXCEED 75 MPH".DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS INSTALLED. H.MISCELLANEOUS: SELF MATING (SMB) PROJECT ADDRESS: D.FASTENERS: 1.ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A 2 x 4 SMB:---------------------- 2"x 4"x 0.044"x 0.100" MANUFACTURED HOME,TRAILER HOME,OR PRE-FAB HOME I. ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 2 x 5 SMB: 2"x 5"x 0.050"x 0.118" WITHOUT A MANUFACTURER'S HOST BEAM. UNITS BUILT PRIOR ° B t 300 18-8,WITH STANDARD FLAT WASHER UNLESS 2 x 6 SMB: 2"x 6"x 0.050"x 0.120" �' Q �?3 GENE SHELLY MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE TO 1994 REQUIRE A SEPARATE ENGINEERED 4TH WALL le` 2 x 7 SMB:---------------------- 2"x 7"x 0.057"x 0.120" 3828 LAURELL VALLEY WITH ACQ PRESSURE TREATED WOOD. SUPPORT,SO THAT NO ADDITIONAL LOADING IS PLACED f ON THE MANUFACTURED HOME. 2 x 8 SMB:---------------------- 2"x 8"x 0.072"x 0.224" ZEPHYRHILLS, FL 2. HEX BOLTS HAS FLAT WASHERS AND TO BE NUT ASTM S A 325,PLATED WITH STANDARD 2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA,THE 2 x 9 SMB:---------------------- 2"x 9"x 0.072"x 0.224" 3. ALL CONCRETE SCREWS SHALL BE,SIMPSON,HILTI,RAWL, ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING 2 x 10 SMB:------------------- 2"x 10"x 0.092"x 0.374" BARRIER REQUIREMENTS OF THE FLORIDA BUILDING CODE � '� 1',. CONTRACTOR: TAPCON,REDHEAD,DYNABOLT,OR APPROVED EQUAL. R 4501.17 IN ITS ENTIRETY. T 4.ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE 3. EMERGENCY ESCAPE&RESCUE OPENING PER FBC R310.1 `., i" SUN STATE ALUMINUM, INC. SHALL BE VERIFIED BY CONTRACTOR&BUILDING OFFICIAL NOTES