Loading...
HomeMy WebLinkAbout15-16798� ' CITY OF ZEPHYRHILLS 5335-8TH STREET (s13)�so-aozo 16798 FIRE ALARM SYSTEM PERMIT PERMIT INFORMATION � � - � _LOCATION.INFORMATION I� Permit Number: 16798 Address: 40047 CR 54 E � Permit Type: FIRE ALARM SYSTEM ZEPHYRHILLS, FL. � Class of Work: FIRE ALARM SYSTEM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS ;Est. Value: Parcel Number: 06-26-22-0000-01500-0000 Ir��prov. Cost: 14,000.00 '. OWNER INFORMATION ` i�ate Issued: 1/05/2016 Name: ALL CRAFT MARINE HOLDINGS LLC �Total Fees: 200.00 Address: 40047 CR 57 E Amount Paid: 200.00 ZEPHYRHILLS, FL. 33540 Date Paid: 1/05/2016 Phone: 813-236-8879 Work Desc: INSTALLATION FIRE ALARM CONTRACTOR S � = - APPLICATION FEES � � � - _. E AUTOMATIC F RE P KLER FIRE ALARM 50.00 FIRE PLAN REVIEW FEES 100.00 I FIRE INSPECTION FEES 50.00 � �` �� • � . Ins ections Re uired� . - � � FIRE ACCEPTANCE Final FIRE ELEVATOR RECALL Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be pertormed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN � FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMME ENT " CONTRACT - PERMIT OFFIC PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- 813-780-0041 L -- O�o.-. /�� PW�fIIA,. "�/ ,g'-,'�,°�' 1r., - - �� - .� . -`�,-�}�., `'ti � ��;;�v I City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: �Ry�L n U���"F"�L ����L ���f����_-� , Date Received: !2 '� 3 — �� f Site: �0 6 Y � �R � � Pernut Type: �l P� A ZAR PV� SioRS'�"AL Lf� T� �� Approved w/no comments:❑ Approved w/the below comments: � Denied w/the below comments: ❑ --���:�= . -� This comment sheet shall be kept with the permit andlor plans. �.. ' �`1' � `� - ' lans Examiner Date Con actor and/or owner `�.�. i � � (Required when comments are present) WAYNE Automatic Fire Sprinklers,Inc. Company's Name: Wayne Automatic Fire Sprinklers, Inc. • � Qualifier Name: Jason G Rountree ^ License Number: EC13005133 � I hereby authorize the Citv of Zephyrhills to issue permits to Sean Watson, Joe Taylor, Vincent Como, Greq Dvkes, and Jeff Kirkpatrick.Whose positions with my company are Desiqn, and Superintendent. . Check one. ( ) This authorization is good for the job at: (X)Any and all permits until further notice. The permit must be signed in front of the building official or his representative. I understand that I remain fully responsible for all acts performed under said permits. lz-�v� rs Date Licer}� older Signature � ***This action must bear the notarized signature of the license holder*"* STATE OF FL RI COUNTY OF The foregoing instrument was acknowledged before me this day of v� 20�by �U �-''e ( name of t e erson acknowl ging) �•�'��: MEGAN L GETTtNGS ( SE �•� _ MY COMMISSFON#FF231398 �y;��;;��` EXPIRES May t7.2019 Notary Sig ure � i.iC7i 39&-0�u3 flwNaNuarrySurvr:n..�� -Personally/Pr fessionally Known ' -or- Produced Identification Type of ID Produced , Regional Office: 3226 Cherry Palm Drive•Tampa, FL. 33619 • Phone: (813) 630-0303 Fax: (813) 630-0312 Ocoee • Pompano • Fort Myers • Jacksonville • Port St. Lucie • Concord, NC � i iiiiii iii�i iiiii iiiii iiiii iii�i iiiii�iiii i�iii iiiii iiii idii , 2016001262 Pemftt No. aera4lD No C1��'�.�0"rl�'����UI�C,1—Cx1<.X� mv� NOTICE OF COM(dENCEMENT �N� � •'o s�a�ea �iAR16� c,,,,,h„�. Phs�a �a`•� �. .,. TNE UNDERSIGNE�heretry eivm notlm�Mffi improvetnent w�f�made to o�M,aln reel property,aatl In aocorCertce wHh Chppkr713,Ploriae Sta►utea, �m W th9(a9owing infortnatioii is p�ovkted tn thfs Nolioe ot CpnmenoeineM� , �. pp , 1. Oesaiotion of Pioperry:Par�F WanU(katlon No. 4t�e'��-��'UtlO.o•-4 i$'C�u`�.('ju�O d � � sueetndaresr. �/�tti`��' CK'�-(� �� ,ei��tlr� F� 3�.`'i'�ld c• •� • 2� OenerelDexiipUcnoltmprovement Tr.IST_4LL_�i) n�G.L+1 �1�'E A.-L/kR�'Yl ���W�, ��� . .. (p O �m.. �i'3 Owrrer lntortnefion or Lessee'IiAa/rmation i(tha l.essee coniracted lor the improVemenC ��r � �dhrn ��:M� (�+.i� K m B �'�z47 Lu���; (1��� ���,5...-.— � � m dress—� Gly tete � 7 IMerest In Rmperty: 7� Name o1 fee Simple TNdtoider. (1I di(ferent from Qwnar�istad abave) � Addrues C &ae Contador:„����.JE�4�7dMATIC. ��.����� '���� fro-�•r�.1 �g-_ �w�,�- � naaress � cny . siata ControUor'e Tekphorte No.. 5�!13'' j0��`���3 5. Surety: Name Address Cily S1ete Amount ot 8ona: S Tekphane No.. ' 6. Let�dcr Neme ' �� �„�D AddlBBB C�y $iat! 0\D Leixfers Telepnorte No.. � ��� 7 Pecaon6 wllhln the&tate of FioiiAa�e \ Igrwtnd Dy;he owner upon whom nalicea or other dewmeMc ma�!bt.cerved ss provldetl by �N� Sedion 713.13(1)(e)(�,FtoAtla Stntutea: B z r+m ��� Nalli2 w►+v N� addross Ctty S;afe ��� TefePhone Number of Oesignate0 Person• ��a N B. In addition to liu�etf,the owner designalea o!_ 3 �o io rooei4a o eopY ofthe lieno{s Notioa as Rrov�ded In Secdon'713.13(1}@1,Flo�lde Statutee. ��..� Tal�pho�Number af Peiacn or Entlty Oesignated Dy Oimer, O � , 9. Ewiretion dete of Na[ice of°Commet�rement(tlie expication de�a mey not be belere the campletion oi constru�ior,arrd finat payment tp Ihe ��Q° camredor,bul v��be one year kom ffie dote bf�retoidG+@ unleu a drf�e�e�l deta'ts specflied): �r 3 �� WARNiNG TO OWNER: ANY PAYMENT9 MAOE BY THE ONRYER AF7ER THE EXPtRAT10N OF TNE NO'f10E OF GOMMENCEMENT � � ARE CONSIOEREO IMPROPER PAYMEHTS UWOER CHAPiER 713. PART 1, SECTION 71J.1J FIORIDA STATUTES, AND CAN � RFSULT IN YOUR PAYING TMCE FOR I.MFRQVEA�NTS T.p YOUR PROPERIY. A NOTiCE OF CQt�tAAEPfCEMEHT Ml1ST BE o RECORDED AND ROSTEO ON THE JOB SITE 6EF.ORf.7H�FIf35T IHSREC]'tON, IF YOU INLEND TO O$TA1N FlNAN�INR,CCTNSULT VYtR1 YOUR LENDER ORAN ATTt)V2N�Y BEfORE COMA6ENCIHO WORK OR'aECORDlNO`fUUR N0TICE.OF COMMEtxEMENT. m � under peneky;of pehury,1 OENfl�8l�B1 1 hBVR c0l61hC tO�O1M,�tlb(ita G/.CWnitleRCeIReM end MB�EC C�Ul.'�fl ifG G'U9 W ShE 0661 pf my knpwled0e nnd belref. STATE OF fLORIDA `� COl1MY OF PASCO � SEgnalute Ownet.a ' see,orU�nrefs or I:essee's Author¢ed OHIcefJDir�etoqPartnmlNlensQer �p �"a�q° �z,00i s.��"'�'f�!.� l �— 'The roregoing Ina�nunent waa edmcwladp/�before th aY of bY � '� ���"" �''•� ae t"�'(Sr G�' (type o1 euthority,e.p„otQEer,tr�stee,aHomay�tad)for � F. /yiY '.G �,�.l�. ._�_ tn W+�Yonbeqaltmvfian� em utad). Poraonatty Kmwn Produc�ldemificatlon❑ Natary S � ' 1 1 �/\ TyD6 of IdaMifiwtion Produced' Name(PriM1���►�, Llt.a..L4�-= I - � MEL,ISSAl.QUATTLEBAUM ' � , ; Notary Public-State oi Florida ' Commiss(pn �t FF1768H8 . „ My,Commieslon Exp.Jan.4,2019" ' wpdatalbeelnoNoecommencartien1pc0530�t0 ` � . - i ,- , � i _ ` `.. . I STATE OF FLORI�A,COUIVTV 0�PASCd� J����'� TNIS IS TO�CERTIECT COPY OF TOHE DOCUMENT Gy��� o ' • �,�� TRUE AND CORR � OR OF PUBLIC RECORD IN THIS OFFICE 0 � ON FILE � • WITN S MY HAND A D OFFICIAL SEAL THIS m Gar�,e r,�.r ' DAY F 2_--1�- � � ' # O ' PAULA S O'NEIL, ERK&C TROLLER � � . DEPUTY CLERK ' '�8� �� B ��`��o��o��� , . age 1 of 2 � � F�L ( �� � 11,e� Mike Wells Pasco Count Pro ert A r is r y p y pp a e Data Current as Of: Weekly Archive - Saturday, March 14, 2015 Parcel ID 06-26-22-0000-01500-0000 (Card: 001 of 002) Classification 41 - Light Manufacturing Mailing Address Property Value ALL CRAFf MARINE HOLDINGS LLC Ag Land $0 40047 COUNTY ROAD 54 Land $254,601 � ZEPHYRHILLS FL 33540-7951 Phvsical Address - See All 2 Bullding $943,083 • addresses�F��scsnown� Extra Features $17,511 40047 COUNTY ROAD 54 ZEPHYRHILLS FL 33540-7951 � Just Value $1,215,195 Legal Description (First 4 Lines) COM SE COR OF SW1/4 OF NW1/4 Assessed (Non-School Amendment 1) $1,215,195 OF SEC 6 TH NOODEG34'16"E ALG EAST BDY OF SW1/4 OF NW1/4 OF SEC 53.20 Ff TO NLY R/W OF Taxable Value $1,215,195 Jurisdiction Citv of Zeohvrhills _ __�_ ___ Land Detail (Card_001 of 002) _ ___._..._�___. .__-- -r -------------___----------- - Line , � � , i--- _.___.�---------- 1 Use___�Description� _Zoning_;___Units ; Type__i __Price _,Condition; Value ---,---- f-- i ---�__--- 1 i 4100 __j LIGHT_MFG._;_ _ OOI1 �_12,000.00 i SF i $1.88 ; 1.00 ! $22,560 �--- � 2 I 4100 LIGHT MFG. OOI1 � 38,000 00 � SF —! $1.50 � 1.00 � $57,000 --------- 1----� -!--- '-.-------- -__--�------i------- ____3 __ �_4100_ _�LIGHT MFG_�_ OOI1 � 50,000.00�; __ SF _ � _ $1.00__;_ 1.00 _ � $50,000 4 4100 j LIGHT MFG. OOI1 240 464:00' SF � "_ � -'"- _ � � � , � ( $0.52 ; 1.00 � $125,041 Additional Land Information ---------------- -- •------- ----------,-- ----------_-------___— � Acres I 7.82 i Tax Area i 30ZH I C de � -- jCommercial Coaie� M54E6AD I Buildina Information - Use 80 - Metal Buildings (Card: 001 of 002) Year Built 1981 Stories 1.5 Exterior Wall 1 Modular Metal Exterior Wall 2 None Roof Structure Gable or Hip Roof Cover Min Roof(Corr. or Sh M) Interior Wall 1 Drywall Interior Wall 2 None Flooring i Sheet Vinyl Flooring 2 Carpet Fuel None Heat None A/C None Baths 4.0 Line i Description � Sq. Feet � � �_ Repl. Cost New ----- ---------------_._ �__-__--------_-_--- - --_______ i -------- 1 -----_,_..�i------- AOF-------�-------- 7,000 i $334,509 ---______..--- --� �_____ 2 ; BAS - ' ---------38,000 -- - -- �------ -$1,068,180 -------, � ----- --- �__------� ----- - ---- - 3 � UUS� � 7,000 j $98,385 _ Extra_Features (Card: 001 of 002)_ "__"_"' "'""_'""'___"__'_""'_"'"_"_' "' '"___'__T"""_"_-_".�._"'_""'__ Line � Description � � Year ' Units I Value ' --�______.______ __,___.___ --_ ._____ ---- -.�---1 ------- -I _�PAV ASP ----- ---____1981 __.___.._ i- --- 21,000 i $5,513 -- - ----------� -- -- ---- -- ------- ----_.._.__ , ------=.------------------__.. 2 PAV ASP i -�---�--_____ --- --- -- ------I-- ------ ---- --!----- 1990 ----._�---- 7,725-`--- .- I � �2,028 --- i - - ----- --- --- - ------------ -------- ' �� - -- _- 3 ---- T DWSWC 1990 2 842 i _ $1,172 ---- -- � -- -- ;- -- - 4 � CLFENCE __ ; __ 1981 ;__ 14 960 : _ $5,610___ - .--. ._...---_.------------,---..__._.___..__._.. ___. _ ____c___-.-. ---- - -_----._ __._._. 5 � LIGHTSM i 1990 ' S $3,188 Sales Historv- See All 6 sales Previous Owner: SKYBIRD PROPERTIES INC PROFIT - - -- ----- ---- ---- - - ---- - --- -- - -----_._----- -- ------_ _ --- --—-- -- I i � DOR -�- - -,-- Month/Year � Book/Page ' 7ype ! EConditioni Amount � ! Code � - --- ______-------- ---- ---- ----__ _ -,. __. . ___ --- -- -- -------�--------- - � `Warran , -__ ._ P $ , -�----_..___._ 02/2014 � 9001 / 0372 � Deedty' �1 � Im roved� 1 500 000 � � : , -- -- _ _.._. . _, _---__ __ _ ----- --- -�-- -------- -�- - � 6444 / 1039 �Warranty` -----!-------- --I-.. .___-- -� --- -- 06/2005 � ' Deed i i Improved ; $2,950,000 -- -- -- -- -;---- --- --- ------ ' __--- - ----- - - -- --------.- - - -'-- -__ 12/2000 4509 / 0995 ! t ! Improved ' $1,900,000 � ; http://appraiser.pascogov.com/search/parcel.aspx?parce1=2226060000015000000 3/20/2015 Git of Ze h rhills Fire � Fax-813-780-0021 s1a-�so-oo2o Y p Y Permit Application ���4 Date Received °��" �� Phone Contact for Permit 813 _ 630 303 - -. - , --- --_._r..._ ._._ W___.____._..___.�---�::-:-.�~:_--�-____�__.__..�___._.=-_-" Owner's Phone Number'_~.---�__._---$13� �--236..�.�-__8879 owner's Name ALL.CRAFT MARINE HOLDINGS LLC Owner'sAddress 40047 COUNTY ROAD 54, ZEPHYRHILLS, FL 3354Q �� �� � Fee Simple Titleholder Name Titleholder Phone Number Fee Simple Titleholder Address m ` w��Y___��___ „_,-----.�- --��� - .-.�� � Yu� � � AD 54 ZEPHYRHILLS, FL 3354Q�� �[.ot# ��� Job Address 40047 COUNTY RO , � Parcel# 06-26-22-0000-01500-0000 Sub Divlsion _ - — - .,,......._�.._..__.____.�_,-. _.�._.._.__.�..�--.._.-v._—_._._.�� (��. ":.._v�_ ,___ _...._ �_��-'_`Y_-..�"`.�_._..,__..�'".._:a....._.....�� _._�.w._.. � . ��Bio-Hazard Waste Storage-ANNUAL Fumigation Tent � Comm Exhaust Kitchen Hood/Duct � Hazardous Materia((Tier H or RQ Feci(ity}ANNUAL � Controlled 8urn o Hood Installatian � Emergency Generator<30 kw � LP/Natura(Gas-installation � Emergency Generator>30 kw � LP/Natural Gas-AhlNUAL Sa[e � Fire Protection Maintenance-ANNUAL � Places of Assembiy-ANNUAt ❑ r y emt � er ❑ Sprinkler ❑ � ❑ Recreationa!Burn Fira Atarm � ❑ ❑ ❑ � ❑ SPsrkiers Hood Cleaning � ❑ 0 ❑ � � Sp«T�kler System instailations Hood Suppression � ❑ ❑ ❑ � Standpipes(Sprinkler Sys} � Torch RoofinglTar Kettle � Fire Alarm Installation � � Waste Tire Storage ANNUAL Fire Pumps .—�-�-- � Flammable Application-ANNUAL $14,000.00, Valuation of Project oFuel Tanks �- � ' _ - - �_�____� _ �..___.=-=--T��,:-��_ .__.._�..��;:��_._."�"_..�..��—�_`�.✓'r --" "�"-�� �-�� �� � ��� �� Wµ��� ^ Company WAYNE AUTOMATIG FIRE SPRINKLERS Contractor Registered Y/N Fee Current Y/ Signature Address 3226 CNER /P �M DR,TAMPA, FL 33619 �icense# EC13QQ5133 ELECTRIGIAN ` Company Registered Y/(�l Fee Gurrent Y!N Signature License# Address PLUMBER Company Registered Y/N Fee Current Y/N Signature License# Address MECHANICAL Company Registered Y/t�l �ee Current 1`1� Signature License# Address C?THEf2 Company Registered Y/N Fee Current Y/N Signature License# Address � ��� Directions:.��___.._ .�.�_.,.._�.__ �____d._._. __.«__--.. Fill out application completely. dwner&Contractor sign back of appiication,notarized(Or,copy of signed contract with owner) !f over$2500,a Notice of Commencement is required(Mechanical work over$500q) Suppiy iwo(2)sefs of drawings with applicable documentafion AtSow'IO-14 days for review after submitta!date. Parcel#-obtained from Property Tax Notice{http://appraiser.pascogov.com) NOTICE �F DEED RESTRICTIONS The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes respansibility for compliance with any applicable deed restrictians. UNLICENSED CONTRACTORS AND CONTRACTOR RESPQNSIBILITIES: If the owner has hired a contractor or cantractars to undertake work, they may be required to be licensed in accardance with state and lacal regulatians. If the cantractor is not licensed as required by law, both the owner and cantractar may be cited for a misdemeanor violatian under state !aw lf the owner or intended contractor are uncertain as to what licensing requirements may apply for the i intended work, they are advised to contact the Pasco Caunty Building Inspection Division—Licensing Sectian at 727-847- ! 8009. Furthermore, if the owner has hired a contractor or cantractars, he is advised to have the contractor(s) sign �� partions of the "contractor Black" af this applicatian for which they wi11 be respansible. If you, as the owner sEgn as the cantractar, that may be an indication that he is not properly licensed and is not entitled ta permitting privileges in Pasco Caunty. CONSTRUCTtON LtEN LAW(Chapter 713, Florida Statutes, as amended) lf valuatian of wark is $2,500.00 or more, I certi�`y that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeawner's Pratection Guide" prepared by the Florida Depar�ment of Agricu{ture and Consumer Affairs. lf the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the`bwner° prior ta cammencement. - CONTRACTOR'SlOWNER'S AFFIDAVIT� I certify that all the information in this applica#ion is accurate and that al! work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to abtain a permit to do work and insta)latian as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be perfarmed ta meet standards of all laws regulating canstruction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other govemrr�ent agencies may apply to the intended work, and that it is my respansibility to identify what actions l must take to be in compliance. If I am the AGENT FOR THE OWNER, ! promise in good faith to inform the owner of the permitting canditians set forth in this affidavit prior to commencing canstruction. 1 understand that a separate permit may be required for e{ectrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construecf ta be a license to proceed with the wrork and not as authority ta violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a carrection of errors in plans, canstructian or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandaned for a period of six (6) months after the time the work is commenced. An extensian may be reques#ed, in writing, from the Building Official far a period not to exceed ninety (90} days and will demonstrate justifiable cause for the extension If wark ceases for ninety (90) consecutive days, the job is considered abandoned WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYlNG TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. !F YOU INTEND TO OBTA! -FINANCING, CONSULT WITN Yt'�UR�ENDER OR AN ATTORNEY BEFORE RECORDING YC} Nt3 O MMENCEMENT. FL.ORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACTO Subscribed and�Yworn to(or affirmed)before me this � cr'i�,ied,�d bworn (or ir ed)befo�me this � y Who islare personally known fo rne or haslhave produced Who is/are ersanall now" to rne or haslhave produceci as identification. as identification. C ,� Natary Public Notary Public Cammissian No. Cammissio o. �.� � Cta�t �_ �.�-2�t�� _ Name of Notary typed, printed or stamped Name of tary typed,printed or stampe --------_.... :?o;�':`"e�c. �Vt�Gs4N L GETFiA1G� w, �; '�IY CqMMISSION#FF231398 :Y,�'. �: �Ewi�� EXPlRES M8y 1T,2Q;g i.lC."�39r,_:;:y;i Ckiruf•rNaw: YSorvr.C.wW� j I I � ( ; ; WA��NE Automatic Fire Sprinklers, Inc. 3226 Cherry Palm Drive—Tampa,FEa�ida33819 Phone(813)630-0303—Fax(813)630-0312 FIRE ALARM QUOTATION Florida EF200009'70 North Caralina 29b11-SP-FA/LV October �5, 2Q l 5 Century Boats 40Q�7 County Road 5� East Zephiyl�ills, FL Re: Centur� Soats Fire Alarm Wayne Automatic Pii•e Sprinklers, [nc. is pleased to provide ypu��ith the follo�a�ing quatation for tt�e fire alarm system insta3lation at�he locatian above. PRtJPOSAL BASIS: - Site Visit T'his proposal is ta provide and install a new fire alarm system at Century Baats in Zephryhills,FL.The tire alarm�vill bring the facility into compliance with the local authority having jursidiction.This proposal is contingent upon approva} �vith the local autharity.There will be fuli coverage notification thraughout the office ar�ca.The secand floar stora�;e area will have a pull station at the top of the stairs as i wel) as a notifica�io�l device.The warehouse area wi11 require notificatian coverage per Flarida Building Cade 907.2.4.Tl�is coverage is included in this proposal. Wayne Automatic will attempt to avoide a fire watch condition by providing a temporary monitoring � solution for the sprinkler riser. During this time, if a waterflo�v device activates,the local authority would be notitied. The tempar•ary monitoring solution is contingent ttpon both acceptance afthis proposal and the local authority accepting it as a temporary avaid�nce of a�re�vatch condition. If ihe local authority accepts this saiution, Wayne Aatomatic wili charge a time and material service call to install the manitoring.The cui•reT�t hourly rate is$89/hour with a trip charge of�55. In additian, 120VAC power wiE1 be reqt�ired at the lacation af the sprinkle riser. WARRANTY& GUARANTEE: Wayne A�itotnatic !^ire Sprinklers, Inc.will furnish all manufacturers �varranties and instructions. Wayne Autom�:tic Fire Sprinl:lers, Inc. wil) provide a twelve{12)month gu�rantee covei•ing defcctivic enuipment,m�terials, and workntanship. The�;uarantee is to stari on the date ec�uipment is placed in service. TAXES& PERMITS: This qtiotation includes applicable sales taxes and pennitting fees. EXCL(�SIONS: 7'he following are not included: ♦ Ceniral Statian Monitoring. ♦ Noiice of commencement. ♦ Painting or patchwark necessary as a rest�tt of tliis instal]ation Priee........................................................................................................�l�#,040.00 � __ 1 I , ., :, NCTTE: Prieing on this quotatic�n is valid for a period of thirty�(34)days fram the time the quotation is accepteci. Materials purchased for the project after the thirty(30)day period has , expircd are subject to price adjustments that reflect increases in the current cast af such m�aterials. Such materiat price ad,justments witi increase the contracfi sum antl he pracessed by means of a � contract change order. This propasal may be withdra�vn by Wayne Automatic Fire Sprinklers if not acce�ted�vithin thirty{30}c3ays ar if a contract agreeabie tc�both�art'ses cannat be negfltiated. N{)TE{Owner duties}: As required by 4A.64.006 Florida Fi�•e Prevention Code,NFPA 2�4-1.2 and NFt'A 72 �-1.2, it is the Owner's responsi6ility ta properly maintain the Fire Sprinkler and Fire Alarm System(s). To tlae_fullest extent permitted by law,the Cantract�r shall indemnify,c3efend and hald I�armless the Subeantr�ctar, his agents and employees, from and against claims,damages, losses and expenses, including but not limited to attorney's i"ees, arising o�.tt of or resulting fram all lasses caused or cantributed to by the Qwner's failiire ta properl}t Test, Inspect and Maintain a14 fire protectioi�system(s� in accordanc�with NFPA 2� and NFPA 72. Best re�ards, }�"�� Brian NT Davis Alarm sales Representative NICET III Fire Atarm ID: 128'717 Ce11813.399.4022 � bmciavis�tt waynefire.cam Y(JUIt ON�-STO�' SAFE'I'Y SOI�UTION T4 INSTALGATIC➢N, INSPECTIC}NS,S�R'VTCE AND M�NITORING OF FIRE A�ARMS, S�CURITY AND FIRE �120TECTTCD�T SERVICES Wayne Automatic Fire Sprinklers, Inc. Locations: Oca�e 407-6SG-3430 Ft Myers 239-433-3030 Jacksonville 904-268-3030 Tam�a 813-b30-0303 Pompano 954-91�-3030 North Caraiina 70�-782-3032 ZEPHYRHILLS FiRE DEPARI"MEIVT 38410 6th Ave Zephyrhills, FL 33542 FIRE SERVICE USER FEES Occupancy No.: Plan No.: Contractor: Business Name: �'S�'C��- 2r Billing Address: Business Address: ���'�f7 �� �'�- ��� B�siness Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE ALARM FEE SitePlan N/C Annual N/C Sprinkler $50 1stAlarm N/C Multi-Family/Commercial .06 sf 1st Re-inspection N/C Standpipes $50 2nd Alarm N/C (Minimum Charge$25.00 � 2nd Re-inspection $100 Fire Pump $50 3rd Alarm N/C � Plan Revisions DBL 3rd Re-inspection $250 Hood ,50 4th Alarm $100 4th Re-Inspection $500 Fire Alami 5th Alarm $150 SPRINKLER SYSTEMS (Business closed until $50 6th Alarm $200 0-25 Heads $50 violations corrected) Natural Gas $50 NON COMPLIANCE $150 26 plus Heads $100 SPRINKLER SYSTEMS Fuel Tanks- Per�ank $50 STANDPIPE SYSTEM Hydro Undergrounds $45 Sparklers $100 � Per Riser $50 Hydrostatic Test $65 per system Fire Works $500 FIRE PUMP Acceptance Test $45 persystem Camp Fire $25 � Per Pump $100 Hydrant Flow $75 Controlled Burn $100 FIRE ALARM SYSTEM Hood/Duct $50 0-25 ' es._-----$5fl, RE-AL-AR S-- TE`M�• Place of Assembly $50 ann�ai 26 plus Devices System Acceptance $50 Fire Protection $25 SUPP 10 SYSTEMS l-Acyeep e $50 Flammable Application $50 qnnuai Wet $50 OTHER Waste Tire Storage $50 Annual Dry $50 Fire WalUSmoke Wall $15 per wau Generator<KW $100 CO2 $50 LP Gas $25 per tank Generator>30 KW 150 Other $50 Natural Gas $25 persystem Bio-Hazard Waste $100 Mnual KITCHEN EXHAUST Fumigation Tenting $50 � Hood/Ducts $50 Tent 10'x10'or greater $15 pertent Torch PoUApplied $50 OTHER Fire Pump $45 Haz.Materials $100 Mnual LP Installation per tank $50 Fire Suppression $30 Fuel Tank Installation $50 System Acceptance ❑ (Per Tank) $50 B Exhaust Hood/Duct $30 Natural Gas Installation $50 Re-inspection DBL (Per System) (other than annual) �Spray Booth $50 � Inspection scheduled DBL � and cancelled less than 24 hours � Construction Insp. N/C �? Emergency Vehicle A� $50 �' FALSE ALARM PLANS TOTAL� INSPECTION TOTAL� PERMIT TOTAL� TOTAL� � lao��, �J GRAN TD OTAL ��,. Comments: Date: I i � S Inspector: nm � CENTURY BOATS 40047 CR-54 ZEPHYRHILLS, FL SUBMITTAL DATA Autor��ti� Fi�� � �`ir�kl��� Ir��. � � 3226 CHERRY PALM DRIVE TAMPA, FLORIDA 33619 PHONE 813-630-0303 - FAX: 813-630-0312 �ti:�.��x�������: t '�z1i �:���•y ���������� l.Jd.{�N�dIJti '��weP���vCl� I . • . - - - . . • -. -• � SILENT IntelliKnight° 5808 KNIGHT Single Loop Addressable �, Fire Alarm Control System by Honeywell The convenience of an addressable fire alarm control panel in a cost-effective � easy to use package. IritelliKnight Model 5808 is a 127 point class leading single loop addressable fire alarm control/communicator system. 5808 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description The basic 5808 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 _ serial/parallel printer interface module (for printing system '���y� reports), and 5496 intelligent power module. 5808 supports ° Hochiki or SK protocol devices. 5808 also features a powerful buift-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring o location. Features • Built-in support for up to 99 SK detectors and 99 SK modules • Built in support for 127 Hochiki devices o • Up to 125 zones and 125 output groups • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator Model 5808 • Central station reporting by point or by zone • Programmable date setting for Daylight Saving • Supports Class B (Style 4) and Class A(Style 6 or 7) Time configuration for SLC • Plex-2 door option combines a dead front • Distributed, intelligent power - cabinet door with a clear window, limiting • Drift compensation access to the panel while providing single • 13 pre-programmed output cadences, (including ANSI- button operation of the reset and silence 3.41), and 4 programmable outputs functions • Notification circuits can be configured as 2 Class A(Style Integrated dead front panel protects operator Z) or 4 Class B (Style Y), or auxiliary power for resettable, from exposure to electrical components constant, or door holder power • The FACP enclosure features a Plexiglass� • Built-in annunciator with 80-character LCD display viewing window to protect annunciator • RS-485 bus provides communication to system accessories • Acknowledge function allows operator to keep � • Built-in RS-232 and USB interface for programming via a track of event status PC Installation • Upload or download programming, event history, or The 5800 can be surface or flush mounted. detector status via remote or direct connection • Improvements in SKSS deliver five times faster Compatibility upload/downloads The 5808 SLC supports multiple device types of the • Built-in synchronization for appliances from AMSECO, same protocol: Gentex�, Faraday, System Sensor�, and Wheelock� • SK(System Sensor) • One Form C trouble relay rated at 2.5A at 27.4 VDC and • Hochiki � two Form C programmable relays rated at 2.5A at 27.4 You cannot mix Hochiki and SK devices on a FACP. VDC . . - - - . • . -. • . seao sess�o,eyesa ��r3 -_-� � --�—���7—' T� —�--� r�-x� i ��;r ui �l �'---� ---�.-i.d �ir..� �..•'',��,>:i., _ � rw,, 6� n�! ` �.�,�.� ,�,a. u�y;.. �o�; � ;� i •�� v„�. °�,m ��: y��.,.�.� ew� �� �,o..,.� � � � � , �_ i ,�Kk°,°�,.,W ,,,,y � � � � I�I ���`� � � 'VO � �. i. �. . .�� � .—. ------ �-K�-- ----�-----�--�--�—�----�✓ ����m���u�o„� o e en«.� eRa�n uq�f� �� o.�..,woa �uaea.vri,��n:_tima.r.� ,Wfncv�uwvebL„v��L+ro' P+uDwvu <svwu.bn�r�xrau 6eu r.w yy�pi. �m°�� _ � � � � 5496 ' in.,m '� E I ` 5808 ' Specifications for automatic, manual,waterflow, sprinkler Miscellaneous Accessories Electrical supervisory(DACT non-coded)signalling 5660 Silent Knight Software Suite Primary AC: 120 VRMS at 50/60 Hz, services. PC-base software for FACP UL Listed 2.75A CSFM 7170-0559: 142; programming. Upload and view panel Total Accessory Load: 6A @ 27.4 MEA 429-92-E Vol. XIV account information, event history, and VDC detector status. Notification Power• 6A @ 27.4 VDC, S-BUS AcCessories 5670 Silent Knight Software Suite power-limited 5860/R Remote Fire Annunciator End-user facility management software Standby Current: 170 mA Features the same 80 character backlit allows viewing of detector status and Alarm Current: 325 mA LCD display keypad and firefighter's key event history via modem or direct Notification &Auxiliary Circuits: switch as the 5808. 5860 is gray and connection. 3A @ 27.4 VDC per circuit,power- 5860R is red. limited Plex-2 Door 5496 Intelligent Power Module Dead front cabinet door with clear Battery Charging Capacity: 7.0-35 A 6 amp notification power expander that Window to limit access to the FACP. AH provides four additional power-limited Battery Size: 18 AH max. allowed in notification appliance circuit outputs. RBB FACP. Larger capacity batteries can Remote Battery Box Accessory be housed in an RBB accessory 5880 LED/10 Module Cabinet. Use if backup batteries are cabinet Features 40 LED outputs, 8 normally open too large to fit into FACP cabinet. dry contact inputs and one piezo output. Dimensions: Physical Flush Mount Dimensions: 5865-3 and 5865-4 16"W x 10" H x 6" D(406 mm W x 254 Remote LED Annunciator mm H x 152 mm D) 14.5"W x 24.75" H x 3.5" D Features 30 programmable LED (15 red (36 8 W x 62.9 H x 8.73 D cm) and 15 yellow) outputs and a piezo Hochiki and SK Devices Overall Dimensions: sounder.The 5865-4 adds a silence and See the specification sheets listed 16"W x 26.4" H x 4.65" D reset switch to the package. below for a complete listing of the (40.6 W x 67 H x 11.8 D cm) Hochiki and SK devices. Weight: 28 Ibs. (12.8 kg) 5824 Serial/Parallel Printer 53624 Hochiki Devices data sheet Interface Module Color: Red Provides one parallel and one RS-232 53623 SK Device Protocol Devices Telephone Requirements: serial port for connecting a printer to 5808. data sheet FCC Part 15 and Part 68 approved Use to print a real-time log of system Type of Jack: RJ31X(two required) events, detector status reports, and event Approvals history. NFPA 13, NFPA 15, NFPA 16, NFPA 5883 Relay Board 70, & NFPA 72: Central Station; Features 10 general purpose Form C IntelliKnight&JumpStart are Registered Remote Signalling; Local Protective relays. Used with 5880 module. Trademarks of Silent Knight Flexput is a Signalling Systems;Auxiliary Trademark of Silent Knight Protected Premises Unit; &Water Deluge Releasing Service. Suitable ; ' SILEN,I, This document is not intended to be used for installation purposes.We try to MADE IN AMERICA I keep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are 350386 Rev.G subject to change without notice. For more information,contact Silent Knight O 2010 Honeywell International Inc. by Honeywell 12 Clintonville Road,Northford,CT 06472-1610. Phone: (S00)328-0103, Fax:(203)484-7118.www.silentknight.com i ' \ � �-• SILENT 58C0 Remote Annunciator KNIGHT � Bring the power to control an IntelliKnight by Honeywell fire alarm contral panel fo every . area within your #acility. Now you can operate and pragram your IntelliKnight system from up to eight locations throughout your facility. The 5860 remate annunciator pravides the same advanced, easy-to-use interface faund on the IntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and i ' errar-free system operation.All operatians—including reset, silence, detector status checking, fire drill, and ; programming—are identical. Access to the system is thraugh a firefghter's key or an access cade. Far security, a specia! installation cade 'ss needed for programming functions. 7he 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate yaur nearest source, please call 1-800-328-0143. Description multiple 5860s .---_ _. _ _ �.__..__.�___� , _�._ Features include an 80-character • RS-485 interFace to panel � - backlit LGD providing easy-ta- • Operation and appearance is � �� -� ������� � ��' y.._.,.«... understand system messages. The identical to 5860 built-in ` d �.:'� annuncia#ar is erganamically annunciator �� • -�- -� ' � ` - � ..�._..: ���•_;`; ,. . designed with over-sized buttons • On-board piezo sounder audibly .. ;�;� ,��y�, �, � for the mast frsquently used indicates alarms, troubles, and � ;3x _� �,,�;�. ,� .+��.�.�,, � � features, like Reset and Silence. supervisaries � #. � �,�� ,�, ' In additian ta status messages ' Five status LEDs for alarm, a .� +�.�� �,t. supervisary, trauble, si[ence and disp(ayed on the LCD, there are AC power canditions five LEDs for alarm, supervisary, . Wiring lengths up to 640Q ft. from ��i� troub(e, silence, and AC power the FACP (depending an wire �gg� status. gauge and number of devices an SBUS) Environmental The annunciator is avai(ab(e 'sn gray . UL listed, complies with NFPA 72 Qperating Temperature: 32°F– to match virtually any decor and 120°F (0°C –49°C) red for applicatians where the • ���M approved annunciatar must stand out. The Electrical Specifications Numidity: 10% –93% non- annunciator enclosure can be Qperating VoEtage: 24 VDC candensing surface or flush mounted.A trim Standby Current: 20 mA max Compatibility ring kit is available for surface Alarm Current: 25 mA �he 5860 is compatible is the mounting. fallowing FACP's: Wiring Distance: 6,OQp max. from . �ntelliKnight 5820XL FACP Features FACP (depending an wire gauge • 8Q-character backlit LCD display and number of devices on the • IntelliKnight 5808 FACP (4 lines with 20 characters on Sg�s} • IntelliKnight 5700 FACP each line) • Tactile and audible feedback Max Per System: 8 Approvals/Listings (, • Accepts user cades ar fire Mechanical Speci�cations NFPA 72; UL Listed; fi hter's ke CSFM 7170-0559: 135; 9 Y Physical 9.1"W x 7.4" H x 1.5" D • Larger keypad buttons for system {23.'{ W x 18.8 H x 3.8 D cm) MEA 429-92-E Vol. IX; reset and silence FM Appraved , • Install up to eight 5860s per Shipping Weight: 2.8 Ibs (1.3 kg) FACP Color • Available in red or light gray 5860R: Red • Support for simultaneous use af �8�4� Gray I \ f i r 58�Q Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to eight remote anntanciators. Remate annunciatars shall have the same control and display layout so as to match the appearance of fhe built-in annuncia#ar. Remate annunciators shall be available in two calors, red ar light gray. Remote annunciators shall have identical functianality and operation as the built-in annunciator.All annunciators must have an 80-character LCD display and must feature five LEDs far: General Alarm, Supervisary, System Trouble, System Silence, and System Pawer. Ail controls and programming keys are silicone mechenical type with tactile and aucSible feedback. Keys have a travel of .040 inches. Na membrane style buttons will be permissible. The annunciator must be able ta silence and reset alarms through the use of a cade entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system pragramming ta authorized 'mdividuals. The can#ral panel must aliow all annunciatars to accommodate mul4iple user input simultaneously. . Wire F2uns Up ta 6000 Feet Fram FACP � r' .�� ��- I t ..:_ � } ;' __ �,I � ' ��,o��ro A { �E��u;au cs �' � '��u�,u� A 1 r rSBUs � � ouuQy`r.ta, �� avucf�°'pt� , q,�a CIpU � ;G o't� t� �/� � I °.�_�,ov ��� � .��avv`v_��. � j',,�,'--..��`ry_:__�... � .._ _ _.._._._- �__._,�...._....._._ � 5864 586p 5860 Up to Efght 5860s Per System Compatible IntelliKnight FACP ardering Infarmatian 586QR Remote Annunicator four line LCD annunciator with 20 characters per line. Fted. 5860 Remote AnnunciatocFour line LCD annunciator with 20 characfers per line. Gray. Accessories 5860TR Red Trim Ring for surface mounting. 5860TG Gray Trim Ring for su�face mounting. SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA to keep our product informatian up-to-date and accurate.We cannot cover KNIGHT FORM#350224 Rev E all specific applicafions or anticipafe al1 requirements.A11 specifications are a- subject to change without notice.For more infarmation, contact Silent O 2010 Honeywell International Inc. by Narl8ywe11 Kn'sght 12 Clinta�ville Road,Northford,CT 06472-1610. Phone:(800)328-01q3, Fax: (203)484-7118. www.silentknight.com r� � � CQOPER Nofification �� ' ED�`t� Finally, Design and Safety Meet... . - ti� w , � , t= ��_:�_. � �;�� _ �q' ; _ .__-�-.�;,,g. � .x;�.�r ��. � T��: i `�4� ;��a°:� , ' �G: -�:�:��;=���`�; ���Fl���a ��� t�;- �. � � +S 9 1 - , �.{ �` . - -*at ' - +� '- � � i � �. tP,#.8`�L ' -. - . _. ..�-..»:_.. . �i � Ceiling _ � I _' Wa1] Description: The Wheelock°ExcederT"'Series of notification appliances feature � a sleek modern design thatwill please building awnerswith reduced - $aVe Up t0 48a�p ICl CUPI'@11t C�faW* total cast of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, , low current draw,no tools needed for setting changes,voita�e test - Up to 9 models now in "� appliance , painfs,12124 VDC operafion,uniuersal maunting base and mu3tiple mounting options for both new and retrofit construction. p 14% ** - Save u to cost of installation The Wheelock�ExcederT""Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appiiances on the notification appiiance circuit.Aii strabe � Sleek Madern Aesthetics models feature an industry first of 8 candela setfings on a singie appliance.Models with an audible feature 3 sound settings(90,95, 99 d8).All switches ta change settings,ean be se#wifhout fhe use , of a tool and are located behind the appliance to prevent#ampering. � Finger Slide Switches Wall models feature voltage test points to take readings with a voltage meter far troubleshoofing and A}-{J inspection. The Wheelock� ExcederT"' Series of wall and ceiling notification `"�� Voltage Test Points appliances feature a Universal Maunting Base (UMB} designed to simplify the installatian and testing of horns, strobes, and - combination horn strobes. The separate universa! mounting Multiple Voitages base can be pre-wired ta allow fu(i testing of circuit wiring before ' the appliance is installed and the surface is finished. It cames campletewith a Cantacf Coverfor pro#ection against dirt,dusf,paint 3 AudibEe Settings and damage to the contacts. The Contact Caver a(so acts as a �� so,se, ss ds shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed � incarrectly and prevents #he appliance from being installed while �� 8 Candela Settings*"* it is on the UMB. Wl�en the Contact Caver is removed the circuit �u Wall-15/1575/30/75/95/110/135/185 ; will shaw an open until the appliance is installed.The UlViB allows ce�tzng-tislsalsol��lssit�51�ea1777 � for consistent installation and easy replacement of appliances if *** ; required.Wall models provide an optior�al locking screw for extra �� Universal Mounting Base secure installation, while fhe ceiling models provide a captivated �e1��ng and WaII screw to prevent the screw from felling during installation. Mou�tS to s aackbox Types � Environmentally Friendty Low Current Draw Campatibility and Requirements -Synchronize using the Wheeiock`�Sync Modules or panels with built-in Wheelock�Patented Sync Protocol -Cornpatible with UL"Regulated Voltage" using filtered VDG or unfiltered VRMS input voltage -Strobes produce 1 flash per second aver the"Regulated Voltage" range *Compared to competitive models "`Patented ' **Gompared to previous models NOTE:Al)CAUTIONS and WARNINGS are identified by the symbol,i�.All warnings are printed in bold capital letters. �, WARNtNG: PLEASE READ THESE SPECIFICATEONS AND ASSOCtATED INSTALLATtON tNSTRUCTidNS CAREFU�LY SEFORE USING,SPECiFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLA710N INSTRUCTlONS. FAlL.URE TO CQMP�Y WITH ANY QF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COU�D RESULT!N IMPROPER APPLICATION, {NSTALLATiON AND/dR OPERATION OF THESE PRODUGTS IN AN EMERGENCY SITUATION,WNICH COULD RfiSULT iN PRflPEt2TY QAMACsE,AtVD SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Nates: General Notes: •Strobes are designed to flash at 1 flash per second minimum over their"ftegulated Voltage Range" •AIi candeta ratings represent minimum effective strabe inte�sity hased on UL Standard 1971, •Series Exceder Strobe produots are Listed under UL Standards 1971 and h64 for indoor use with a temperature ranc�e of 32°F to 120°F(0°C to 49°C)and maximum humidity of 93%{±2�/a)UL 464(85°/a UL 1971). •Series.Exceder horns are under UL Standard 464 for audible signal appiiances(]ndoar use oniy}. i � � ' • • � i Strobe Ratings per U�Standard 1971 24 VDC 124 FWR 12 VDC Model Regulated Vol#age 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC ST 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 0.205 0.253 0.110 0.140 STC 8.0-33.0 4.061 0.085 0.1 Q3 0.135 0.163 0.182 0.205 Q.253 0.110 Horn S#rabe Ratings psr UL 1971 &U�464 at 24 VDC .. �:� 24 VDC 12 VDC Model �egulated Voltage 75 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159 HSC 8.0-33.0 4.082 0.102 0.141 4.148 0.176 0.197 0242 0.2$2 0.125 . ,.� 24 VDC 12 VDC Modei �egulated Voltage i 5 15175 30 60 75 95 110 115 135 i 50 i 77 185 15 151T5 Ra�ge VDG HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 0.272 0.122 0.153 NSC 8.Q-33.0 0.073 0.087 0.128 0.139 0.163 Q.i86 0.230 0.272 0.122 •� .:• 24 VDC 12 VDC Model �egulated Voltage 15 15175 30 60 75 95 11 Q '{15 135 150 177 185 15 15i75 Range VDC HS $.0-33.0 0.065 0.075 0.0$4 Q.136 Q.i57 0.184 Q.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120 Fiarn Ratings per UL 464 '� � ��4,� �:k ��-`-a =�='' ''� � '; . c��;•=^�,. 5-�°� �=' ., '°`«;�,- '� �,�:,, ° ��.., �, : Modei Regulated Voltage �9 dB 95 dB 90 d8 �,� �� �� � , '�*�`�'��"�`���� �,�� Range VDC -> °�,.,�,`='�- � ., ��,r;.,. � �' vt � _at f '-_'�rr,way� ;4�' ' � 'b HN 16-33.0 0.064 0.044 0.022 _ s�" � � ��;e-�.,�- � , HNC 16-33 0 0.084 OA44 OA22 a .�,�. ; HN 8.Q-17.5 0.047 0.026 0.017 - ¢>;:, �'aa " + i ` '"� '��� �� � HNC 8A-17.5 0.047 0.026 O.Oi7 y ����b�i 1 �.: � , �,. I --• *UL.max current rating is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC unifs). For strobes fhe UL max current is usually at the minimum listed voltage (16 VDC far 24 VDC units). Far audibles the max current is usually at the maxirt�um listsd voltage{33 VDC far 24 VDC units). For unfiltered ratings,see installation instructians. � - - - i , Specification & t}rdering lnfarmation ! Strobe Sync w!SM, * Mounting Model Candeta DSM or 12/24 VDC Options PS-6&PS-8 � ..- � HSR 1511575130t75195t19 d1135/185 X X UMB** • HSW 15/1575/30/75l95/110/138/185 X X UMB'"* � HSRC 15130180!?5195111519541'{77 X X UMB*` � HSWC 15/30/60/75/95/115/150/177 X X UMB** . � . ..- STR 15/1575/30/75/95/110/135/185 X X UMB"* i S7W • 9511575130t75195111011351185 X X UMB'* . STRC 1 S/30/60/75/95/115/150/177 X X UMB*" I ' STWC . 15134160t75195i115/150t177 X X UMB** � � � HNR �' _ � ' X X UMB*" HNW � ` ` w ' '�' a X X UMB** , HNRC � � ` X X UMS** HNWC •• ' . - " " X X UMB*' '12 VDG madeis feature 15&15175 settings "UMB=Universai Mounting Base Model Legend '�.-�'�� � �,�� ��'�`°;r�` NN - Norn v-� - ' �� � -�� � ST =Strobe ,'�" - � �,�� °�' 4 _,,�,. � ' �.,� �``�': HS = Fiarn Strabe � .��� �, r',�'£ C = Ceilin Mount � �� ��'�~�4 � W =White� - ���. � ���� � R = Red ' � � `"� V�� � �` � 1Ri'.. ( 'r � � `� � � � Example 1: STRC=Strobe, Red, Ceiling Mount ,, �'� � ''.,:: �-, ��� , Example 2: HSR= Horn Strobe, Red, Wall Mount ' � ; , � Example 3: HSW=Fiorn Strobe,White,Wall Maunt. �' Example. S Exampte: HSWC , �� �� �, �: - ==r.� � 'z�. --s-� :�,�'�--� `�`` ' �i..i�.IC�,'�.� . . !�.,.� ��„�� _��; w�� ���`*�, �` ' ` � }��:�r�a- � �`�'� y'�,��'.�' �ti.�a.C, n >yk yt r�. =I ��`,.1,�.,J��_ I k�'�: i��'; ( r r. a, �. * �i ��-�' . ; „ `6 'y�y� ,�bw� �t.�„ ..,. � i � ' 1 "" ' 1...��. _ y i.`Yy� ��' �y . � �i,';:.`f , � r�' � " :x�� �,�r� ,4 '��. "" � "�; � _ `�n �(' ' a�i��!i�K� . "., . . - - :� p�� - 'W� � ',��',r'�' , .��R#���- .�� � �'J X '£ ` `�." ;�( . • � ! ���.. . .4f .... . �=u *UMS � � Contact Cover -�.�,-: . . . - . . . . . - . . . . . . . . • • ' !• f r i � • • i • •i • • � � ' • .. , ' ' _ . _.._. _"__'.., �..... -..,. " ' '_"_ '`_' —' '_.._._ .. .. _. .__.�,_ ' ' ' . ___. ""'_'_"'—.� I � NOTE:Que to canfinuous devetapment of aur products,speciFcatians and ofEerings are subject to change without notice in accordance ; with Coaper Wheelock Inc.,dba Cooper Notification standard terms and aonditions. ; i ! � i ` - . � , 1 Architects and Engineers Specifications � � �------ --- --__--- --- -- ------ - --_ __ _. : The notification appliances shall be Wheelock�ExcederT"^Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B.All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel(FACP)with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan�lens.The Series shall be of low current design. Where Multi-Candela appliances are specified,the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30,75,95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant.The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g.ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three(3)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe,ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang,4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of ' an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel(FACP). The mounting base shall be the same base among all horn, strobe, horn strobe,wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24"H x 4.58"W x 2.19"D. Series HN wall shall measure 5.24" H x 4.58"W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68"x 2.63" D. Series HNC ceiling shall have a diameter of 6.68"x 1.50"D. When synchronization is required,the appliance shall be compatible with WheelockOO's SM, DSM Sync Modules,WheelockOO Power Supplies or other manufacturer's panels with built-in WheelockOO Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1)flash per second over its Regulated Voltage Range.The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with WheelockOO synchronization protocol. — 971 UL Standard 464 California State Fire Marshal (CSFM), ULC Wall Appliances UL Standard 1 Ceiling Appliances—UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC ������ - WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder- Spec Sheet 11/09 . �� :. . � . . '� ,� . � :��•. �� � � .� / _ , �, cooPerNotifcationisWhe210Ck° MEDC SAFEPATH� WAVE� a COOPERNotification 0 � � � � • . - .- • SD500-AIM & SD500-MIM � � � . Addressable Input Modules ,. � � `� ''�� f" �°� ��'� �` � IntelliKnight's addressable contact monitor ' modules combine fast response with pinpoint � �`� location ID. A combination that saves lives and `w=,��� . -:�� ,�-.� � property. ��� :� � The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. � The SD500-AIM addressable input module mounts to a 4 -square box. The SD500-MIM mini input module fits �� inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description • DIP switch programmable for fast The SD500-AIM and SD500-MIM are installation __ �� �_�_ _�—{� P • U to 2500 ft wirin distance from - ' ;- I addressable in ut modules for use with P 9 - � � ;� :��� r��J the Intelliknight fire alarm control either input module to contact � r � �����_�-, panels (FACPs).The SD500-AIM • Use up to 14 gauge wire . = •°. �}„ � N -;; addressable input module mounts to a . UL listed f !^�� ;.;_.i 4"-square box. The SD500-MIM mini f input module fits inside a single gang ElectriCal SpeCifications ��" � I H t?=_' box. Both input modules are designed Standby Current: 0.55 mA ' �- �_,� 1 to be used with pull stations,water flow ------� �--=--' '��1 �-�� � Alarm Current: 23 mA max for one `�-� :-� ��; switches, and other applications 5D500�AlI�1 device;46 mA max for two devices; requiring dry contact alarm initiation 0.55 mA for each additional device �. devices. at i Line Resistance: 5052 max �,�'��'� These modules are supervised, single �� input contact monitors. Using an EOL Mechanical Specifications resistor, they monitor for alarm contact SD500-AIM Physical Description s closures and for open circuit wiring Dimensions: �% ✓ fault conditions. If a fault occurs in the 4.9��W x 4.9" H x 1" D wiring, the module alerts the FACP. (12.4 W x 12.4 H x 2.5 D cm) SD�oo•h11tA Each addressable input module is Weight: 3.6 oz(120.1 g) programmed with a unique signal line Color: Ivory cover plate circuit(SLC) loop address. ' SD500-MIM Physical Description Approvals , Features Dimensions: NFPA 71 & NFPA 72 • Single contact monitor 1.5"W x 2.5" H x 0.7" D i (3.8Wx6.4Hx1.8Dcm) UL864 • SD500-AIM supports Class A(Style Weight: 1.6 oz(45.4 g) CSFM 7300-0559: 132 D) or Class B (Style B) contact MEA 429-92-E Vol. IX monitor wiring Environmental FM Approved for use with the 5820XL • SD500-MIM support for Class B Operating Temperature: (Style B) contact monitor wiring 32°F—120°F (0°C—49°C) • Attractive ivory cover plate with the SD500-AIM Humidity: �Y���� • Small and lightweight size allows for 10%—93% non-condensing K���. flexible mounting options with the SD500-MIM by Woney��rell .� . . - • �- SDSQa-AINI & SD500•IUIIM � � Addressable Input Modules � .� � � Engineering Specifications The contractor sha11 furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The madules shall be UL listed and campatible with Silent Knighf's InteffiKnight FACPs. The SD5Q0-MIM shall flt inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and sha41 be suitable for mounting to a 4"-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate � �� � e T A` R� .- 7 ; .'�:.. _ ��;�,��� ... a;.1r. �.� �c ca �c��s to curb_i �� ( , �{'�`� ; `�' � 43itg i11�T,R1rh��,0�I�r/., •!4"•.,`l� � r .�"",��� �C-S" /! \} � � ~�"'i`-..,,1 ��.:�.' ltL'a3a]._}�,.':��� ,� ( t `� 's�"="' Ea� _ . � `E � €� � 1 �`'�.�`;-� _�f� .�—� � , � 1 _ � �. � _ � ���'^"� ( I � �`� '..'+� y � � ��--.,,� � _ �'.� e3TIl\YiVjk35U3Fu�#^.� I � � i .f'_ ��..`'wY�7� DVhYftUC� } ' � � �...''r-'I~.�`"—.ti� "M .x...,��j�~ I `;-„-4.'_�y��?', fY,:.-t`` , � ' 'Fammau �}-- � .r � � �hdlt�t�fi'ikt3J{j�� � , y��L__ , � � - ; ' ,�-�-, i � Y�.� ; � � u�° , �,�-�:�---+e c' r� � i i C�li i 3�'tl 3'4 . 1 R - � - `. i i ,�``.r� �,�.,y i � ,.�"�� �� 4 iv i i i j f I ; ,�R.. " �.. ,A ��`���� � �t }�^`µ�,-w—`-�,_,,,�1 (�`� ._�'.s.,�c� �'�µ�� t��.Y.-� t S' T� '' �S �t� �_� -i�. �� �� <` � �� a} ;� � �'"��``-�.,-'`���' '�.~l. ���Yt�—1�"� `_`i 7 ' �_ ' ` --�-�"� �-�}�`--' � ',1 ��`" �,..-' 4^�,r _._ _ . .j*� 3,� �` i - �-, l , t—"� --� '�.� �� �-- /l`` �'� ' } " �`'"-• '°—���-' - -�-.�� -' " �.....�..u_._ �., `,�M _ 4,,'', _;I ; i_ j Gompatible FACPs Ordering lnformation 5820XL SD500-AIM Input Modute 5$�g Addressable input module with ivory caver plate. 57Q0 SD50Q-M1M lnput Module Addressable mini input madule. �,`�L��'�' This document is not intended to be used for installation purposes.We try to MADE IN AMERICA ��I�H•I• keep our praduct informatian up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.AII specifications are FORM#350231 Rev C}, subject to change without notice. For more information,oontact Silent Knight O 2008 Honeywell Intemational Inc by Hatl�eyt':ell 7550 Meridian Circle 8uite 100,Map{e Grave,Mn 55369-4927. Phone:(800)328-0103 or 763-493-640p Fax:(763)493-6475. www.silentknight.com . • . - .-� ��.-.. - , SD50�-P� and SD500-PSDA � - � Addressabie Pu11-Station � �� ,,�;' �. �o :��: �,� 4 ti.', :� � �. � .�� ,#.� - 1nte11iKnight's addressable pult stations �'� � � combine fast respanse with pin-paint ��_�. , ��r location ID. The SD5�Q-PS and SD500-PSDA are a single action or dual action addressable manuai fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the �D500-PS/PSDA � provides a fast and practical means of manually initiating a fire alarm signal. The InteiliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The 5D500-PSIPSDA maun#s ta a single gang box and features a rugged metal constructian that lasts and lasts. Gombine aii this wfth the features you`ve eome to expect from Silent Knight- �asy instaliation and stabie operation - and it adds up to a flexible solution far all your fire protection needs. Model SD50a-PS & • Extremely easy to operate SD500-PSDA • Corrosion-resistant gold-plated contacts. � � Addressable Pull • Reflective label makes it easier Station to iacate in iow iigh# The SD500-PS is a single action Operation ° � addressable fire pui) station, and The SD500-PS/PSQA singie action - the SD50Q--PSDA is a dual action pull statians are operated by a pull addressabEe fire pull station. The on the front pull cover of the SD500-PS/PSDA feature rugged station. A plunger switch, wired to metal constructian A terminal s#rip a se[f cantained addressable � on back af the pull station allows module, is released as the pull interconnection of the pull station ta station opens to initiate the afarm. the SLC of an IntelliKnight eantrol Once operated, the cover hangs panel. The SD500-PS/PSDA is down and can be seen up to 100 � designed for indoor use in non- feet away. The puli statian is reset '� �` explosive enviranments. The by returning the front cover to the narmally open initiating point normai upright pasition and contacts are gold-plated to avoid relocking the station with a reset risk of corrasion. The 5D500- key. The reset keys are the same PS/PSDA has been tested by UL keys used on Silent Knight for compliance to the requirements enclosures. af the Americans with Disabilities The SD500-PSIPSDA includes a ACT (ADA). status LED which blinks, indicating SD500-P$ Features that the addressable madule is Ambient Temperature: 32°�to 12a°F • UL Listed cammunicating with the loop. The (o°c to ae°c) • CSFM listed status LED lights continuausly Mourrting: Single gang during an alarm. A dip switch on box - • ADA compliant the addressable module is used to Optional Red Surface Mount Box PS-SMBB • Key reset �Same key as Silent set the unique address. Knight enclosures) • Surface mount back bax �pecifications availabls Operating Voltage: 24VDC ;���,��T Stendby Current: .55mA ������ • Terminals - accept up to 14 Alarm Current: .5�mA gauge wire � �"�-f�����i