HomeMy WebLinkAbout6709 BASSWOOD CIR f
F'f FY'`PRTQ�I, N0�'F'$ '
1 : Service location shall be determined by Florida
Power Corporation.
2: Service shall be sized in accordance with
Article 220.
3: Footers shall be bonded - 250-81 (c)
4: Garage receptacle shall be GFCI protected -
210-8(a) (2) '
�� �
.5: Bath receptacles shall be GFCI protected -
� 210-8(a) (1 ) �-- �
6: There shall be at least (2) small appliance
, circuits i.n the kitchen - 210-52(b) (1 )&(2)
7: Kitchen receptacles within 6' of a wet bar
. sink shall be GFCI protected - 210-8(a) (5)
�?`5: Receptacles outside with direct grade level
t access shall provide GFCI protection -
210-8(a) (3)
9: Shloke detectors shall be installed outside
of each sleeping quarters - NFPA 74
I 10: No wire smaller than (#12 copper) or (#2
aluminum) shall be used - City of Zephyrhills
Ordinance #430
11 : Any items not covered above will come under
the 1991 National Electrical Code.
Y
��� I