Zephyrha.11s Ordinance #430
�tandard Code (D) : Wire size fourteen ( 14) or smaller is
prohibit�ed far any use.
1993 National Electric Code
210-8 (a) ( 3) : All 125--volt, single-phase, 15 & 20 ampere
receptacles installed outdaors where there is
direct grade level access to the r_ecep�acles
- - shall have GFCI pro�ection. -:- ' �`��" �--�, - -
CABOi"�. .
.,--%�
R-215. 1 : Smake detectors shall�be installed outside of each
; separ.a�e sleepi�g.rarea in the 2I[IIIl@C�11'�� vicinity of
the beclrooms and-=bn each additional_ story of the
dwelling, including basements and cellars but no�
��incZuding crawl spaces and uni.nhabitable attics. In
dwellings-or dwelling units with split levels, a smoke
detectar need be installed only on the upper level,
pravided the ].ower level is less than one full stary
below �he upper level, except tha� if there is dcror
--�. _be�.ween levels then a detector is required on each
� level.. All detectors shall be ,interconnected such that
the ac�uation of one alarm wi,l1 actua�e all �lie alarms
in the individual unit and shall provide an alarm which
wi1.1. be audible in all sleeping areas. All detectors
sh�:ll be approved and listed and shall be installed
to manufacturer's instxuctions.
When alteratians, repairs or addi�ions requiring a
permit occur, ar when one or more sleeping raoms are
added or created in existing dwell.ings, the entire
building shall be provided� with smoke detectars ].ocated
as reguired for new clwellings; the smoke detectors
are not required to be interciannected unless other
remodeling consic7.erations require removal of the
appropriate wall and ceiling covering� ta faci3i�.ate ,
concealed interconnected wiring.