HomeMy WebLinkAbout7900 MERCHANTVILLE CIR � ,r � . �
�, - , � � �`.r
�
�ity of :Zep:h�rh�i:l:1s
� �. a
,B�u.�Id°t:r1� �De:partrtle:nt
�Co.r�str.�:�tio.r� �N�otes
Finish flaar he'ght�shal{ be minimum 8"above crown of road (Cir�y-of.Zephyrhills�Ordinance#.237)
Each bedroom�shali have at least ane window sized fra emergency�egress (2001 flarida Building Code#1005.4}
Ductwork and appliances in garage shaii be protecked fram physica!damage{2001 Ffarida 8uiidingiMechanica!Code �
#303.4} �
Tub access sNail compiy with (�00�.�brida BaildingJPtumbing�Code#405.8j to cancea(ed connecCions '
8alanced retu�air shaIl be achieved through the use af transfer ducts or griiles(2001 Piarida BuiidingiMechaeicat ;
Code#601.I�}
Window gfass hazardaus locations shall camp(y witE� (�OQ1.�iarida Buifding Code#240S.Z) ,
u
Installation a�gas appliances requires separate permit�
� 2002 Nationa[ Electrical Code
h
210.8(A)(2�� -AII gatage receptacles shail have GFQ protkection �
�
2�.0.8(A)(3)-Afl outside recept�cles shall have GFQ protection
�
Z10.8{A)(6)-Al1 recept�cfes serving cauntertops in the kitchen.sha!! be GFQ protected i
9 '
21[1.11(C)(3)-Bathroom circuits shall have no ather outiet� � �
210.12(B)��Ali autiets (receptacles, lights,smoke detectors) in dwelling bedrooms shafi be AFCI protected �
�
210.70(A)(3)-Lighting for A/C in attic +
250.52(A)(3)-�oater stee!shall6e used far a ground '
i
406.8(A}�Receptacles in Damp Locatians ;
4 ' ;
4p6.8(B)(1�- Receptacies in Wet Locations ;
�
410.8- Lu�inaires in Ciothes Ciasets
N
422.�.8-Suppart of Ceiting-Suspended (Padd[e) Fans �
�
, . _