HomeMy WebLinkAbout7963 MERCHANTVILLE CIR i ,
�' ,� •i'� -;� =- - .- -. �...
�
b� '
i� �
� ,
i ,
'��
�,, �
�Ci� . of :Ze,p:h�rh�i:i:ls � �
�
:Bt�:iiding �De:partme:nt ;
�Co.rastr.u:Gtio.r� :N�otes .
� ,
�� � :
��
Finish floor hleight�shall be minimum 8"above crown of road (City�of.Zephyrhills�Ordinance#237)
��
Each bedroom shall have at least one window sized fro emergency�egress (2001 Florida Building Code#1005.4) ;
N
Duclwork an�d appliances in garage shall be protected from physical damage (2001 Florida Building/Mechanical Code
�'303.4) I'I •
li
Tub access shall comply with (2001 Florida Bu�lding/Plumbing�Code#405.8)to concealed connections
Balanced return air shall be achieved through the use of transfer ducts or grilles (2001 Florida Building/Mechanical �
Code#601��4) ;
Window glass hazardous locations shall comply with.(Z001 Florida Building Code#2405.2) i
�
I;
Installation if gas appliances requires separate permits !
�i 2002 National Electrical Code �
�i
210.8(A)(2) -All garage receptacles shall have GFQ prottection • ,
�� �
210.8(A)(3)-All outside receptacles shall have GFQ protection �
210.8(A)(6)-All receptacles serving countertops in the kitchenshall be GFC[ protected �
210.11(C)(I3)- Bathroom circuits shall have no other outlets . �
i
210.12(B)�iAll outlets (receptacles, lights, smoke detectors) in dwelling bedrooms shall be AFQ protected ;
i I
210.70(A)(3)- Lighting for A/C in attic
250.52(A)(I)) -Footer steel shall be used for a ground '
406.8(A)- Recep�cles in Damp Locations
� , �
406.8(B)(1)- Receptacles in Wet Locations !
i� ' �
410.8- Luminaires in Clothes Closets
li i
422.18- Support of Ceiling-Suspended (Paddle) Fans