HomeMy WebLinkAbout5420 7TH ST ,
I
. +
_...�►�.
,
:; ,
i ,
' �City of :�ep�:t�rh�i:t:1s
i
; :B�.ildin� �De;pa.r.tme:nt
�
; �Co.nstr.��:+�ti�►.r� :��otes
Finish floor height�sha(i be minimum 8"abave crown of road (City-af.Zephyrhilis Ordinance#.237)
I
Each bedroom�shafl have at least one window sized fro emergency�egress (2001 florida Buitding Code#10�5.4)
Ductwork and�appliances in garage shati be protected from physicai damage(2001 Fiorida.Bailding jMechanicai Code �
#303.4) I ,
Tub access sliaii compfy with (Z001"Florida BuildingiPlumbing�Code#405.8)ta conceaied connectians
�
Balanced retum air shaii be achieved through the use of transFer ducts or grilies (,2001 Florida BuiidingJMechani�at -
Code#60i.�4)
Window glas� hazardous focativns shall comply with {2001 Fforida Buitding Code#2405.2) �
Installation of gas appliances requires separate permits
�� � - _
�
i ZOOZ Nationat Etectricat Cocie
,� ,
21Q,8{A)(�) -A11 garage receptacles shall have GFQ prottectian •
210.8(A)(�)-Aif outside recept�acles shall have GFGT protection
�
210.8(A){,6)-Ali receptacies serving cauntertops in the kitchenshall be GFQ protecked
Z10.11(C)(3)=Sathroom circuits shall have na ofher outiets
210.�.z(B�-A8 o�iets (receptacies, lights,smoke detectars) in dwelting bedroams sha(i be AFQ protected
�
210.70(A)(3)- Lighting for AjC in attic
Z5�.52(A.)(3) -�ooter steel shall be used for a ground
4Q6.8(A)-Receptacies in Damp Locatians
4Q6.8(B�(1)-Receptacies in Wet Locatians
I
410.8- luminaires in Clothes Closets
�
42Z.18� Suppart of Ceiling-Suspended (Paddle) Fans