Loading...
HomeMy WebLinkAbout7967 MERCHANTVILLE CIR r � � • J;uly 18, 2005 City of Zephyrhills Building Dept. 5335 8'�' Street � Zephyrhills, FL 33542 � I Re: 15117-52-0057 � To Whom It May Concern, � �, Please revise the following permit per the engineered letter. Thank you for your assistance in this matter. ' Block/Lot: 0057 Permit#4389 7967 Merchantville Ci -, , 1 � �� Sincerely, I ��- �� Ryan Bazemore ��� Design Manager � �` �� US Home Corporation � � ! Tampa Division �� ` �, ; � � i , � � 600 N. Westshore Blvd., Suite 600,Tampa, FL 33609 •Telephone: 813-769-5277 • Fax: 813-769-5278 •www.ushometampabay.com � -- - i -- � , � r` • , DE �, � DANSCO ENGINEERING, Li C 4 ' P.O.Box 3400 Apollo Beach,FL 33572 Telephone(813)645-0166 E-mail:dengine1@danscoengineering.com Facsimile (813)645-9698 CA 25948 , � � ;i June 21, 2005 ; Mr. Tom Joseph ' US Home Central Florida Division 600 N. Westshore Blvd., Suite 600 � Tampa, FL 33609-1140 � � a RE: ,� Monolithic Footing Oxford 2003 � ; 15117-52-0057, Inventory � DE Job # 250983 � Dear Mr. Joseph: ; i Pursuant to your request, we conducted a limited structural review of the above- � referenced project. Specifically, we revised the plans to show monolithic footing in lie� of stem walls. Please refer to the attached Sheets: 2, S-1 antl S-6 for updated information. / Sincerely, -� ' � ; � DRN� O Ef�GINEERING, LLC ' � - - -- i ; �- - � � .S muel�.A. Greenberg, P.E. -; �Fla. Reg. No. 34245 sg/md^ � - ' i , i G:1Clerical Files\Documents\Letters\US Home�2004 Job Files�250983 mono ftg rev.doc , � � � i I I I � � I I 'i ' ; � � � '� . r, ! r' ���' ' •� �• ,�r y,-_...' ' j . � �ity of :Ze.plh�rl�il:is :B�u:ilding �De,partme:nt . � � � �Co:rast�ru:c�t�o:r� :N�otes ; � + . Finish floor height shall be minimum 8"above crown af raad (City-af.Zephyrhitls Orclinance#237) Each bedroom shali have at ieast one.windaw sized fra emergency egress(2001 floriida Bu�lding Code#�:OOS.4) ' Ductwork and appliances in garage sha!! be protecked from physica! damage (2001 Florida 8uilding/Mechanical Cade , #3Q3»4) Tub access shall camply with (20Qi Fiorida Buitding/Plumbing�Code#405.8)to Iconceaied connections � 8aianced returri air shall be achieved through the use af transfer ducks or griiles(2001 Fiarida Building/Mechanicat Code#601.4) I Windaw glass hazardous lacations shall comply with.(2001 Florida Bu�lding Cade#2405.2) Insta!latian af�gas appliances requires separate permits /i 2002 Nationai Eiac�rical Code -----�"�� �—...�/ ' 21�.8(A)(2)'-ASI garage receptacies shall have GFQ prottecCion 210.8{A)(S)-A!1 oufiside recept�cles sha!! have GFQ protectian 210.8(A){6)-All receptaGles seroing countertops in the kitchen shall be GFQ protected 210.11(C)(3)- Bathroom circuits shall have no otF�er autlets 210.12(B}-,A(1 outiets (receptacies, iights, smake detectars) in dweiling bedroams shali be AFC[ protected 210.T0(A)(3}-Lighting far A/C in attic � ZSO.S2(A)(3)-Footer stee)sha!! be used for a ground 406.8(A) - Receptacles in Damp Locatians � � 406.8(B)(I�- Receptacies in Wet Lot�tions � � a 410.8- Luminaires in Clothes Closets � � 422.18- Suppart of Ceiling-Suspended (Paddle) Fans � 1 i ; . . . ,