HomeMy WebLinkAbout7967 MERCHANTVILLE CIR r � �
•
J;uly 18, 2005
City of Zephyrhills Building Dept.
5335 8'�' Street
� Zephyrhills, FL 33542
� I
Re: 15117-52-0057
�
To Whom It May Concern,
� �,
Please revise the following permit per the engineered letter.
Thank you for your assistance in this matter. '
Block/Lot: 0057 Permit#4389 7967 Merchantville Ci -,
, 1 � ��
Sincerely,
I
��- ��
Ryan Bazemore ���
Design Manager � �` ��
US Home Corporation � � !
Tampa Division �� ` �, ;
� �
i
, �
�
600 N. Westshore Blvd., Suite 600,Tampa, FL 33609 •Telephone: 813-769-5277 • Fax: 813-769-5278 •www.ushometampabay.com �
-- - i -- � ,
�
r` • ,
DE
�, � DANSCO ENGINEERING, Li C
4 ' P.O.Box 3400
Apollo Beach,FL 33572
Telephone(813)645-0166 E-mail:dengine1@danscoengineering.com
Facsimile (813)645-9698 CA 25948
,
�
�
;i June 21, 2005
;
Mr. Tom Joseph '
US Home Central Florida Division
600 N. Westshore Blvd., Suite 600
� Tampa, FL 33609-1140
� �
a RE: ,� Monolithic Footing
Oxford 2003 �
; 15117-52-0057, Inventory �
DE Job # 250983 �
Dear Mr. Joseph: ;
i
Pursuant to your request, we conducted a limited structural review of the above- �
referenced project. Specifically, we revised the plans to show monolithic footing in lie�
of stem walls. Please refer to the attached Sheets: 2, S-1 antl S-6 for updated
information. /
Sincerely, -� '
� ;
� DRN� O Ef�GINEERING, LLC '
� - -
-- i
; �- - �
� .S muel�.A. Greenberg, P.E.
-; �Fla. Reg. No. 34245
sg/md^ � - ' i
, i
G:1Clerical Files\Documents\Letters\US Home�2004 Job Files�250983 mono ftg rev.doc ,
�
� �
i
I I
I
�
� I
I
'i '
; �
� �
'� .
r, ! r' ���' ' •� �•
,�r y,-_...' '
j .
� �ity of :Ze.plh�rl�il:is
:B�u:ilding �De,partme:nt .
� �
� �Co:rast�ru:c�t�o:r� :N�otes
; �
+ .
Finish floor height shall be minimum 8"above crown af raad (City-af.Zephyrhitls Orclinance#237)
Each bedroom shali have at ieast one.windaw sized fra emergency egress(2001 floriida Bu�lding Code#�:OOS.4) '
Ductwork and appliances in garage sha!! be protecked from physica! damage (2001 Florida 8uilding/Mechanical Cade ,
#3Q3»4)
Tub access shall camply with (20Qi Fiorida Buitding/Plumbing�Code#405.8)to Iconceaied connections �
8aianced returri air shall be achieved through the use af transfer ducks or griiles(2001 Fiarida Building/Mechanicat
Code#601.4) I
Windaw glass hazardous lacations shall comply with.(2001 Florida Bu�lding Cade#2405.2)
Insta!latian af�gas appliances requires separate permits
/i
2002 Nationai Eiac�rical Code -----�"�� �—...�/ '
21�.8(A)(2)'-ASI garage receptacies shall have GFQ prottecCion
210.8{A)(S)-A!1 oufiside recept�cles sha!! have GFQ protectian
210.8(A){6)-All receptaGles seroing countertops in the kitchen shall be GFQ protected
210.11(C)(3)- Bathroom circuits shall have no otF�er autlets
210.12(B}-,A(1 outiets (receptacies, iights, smake detectars) in dweiling bedroams shali be AFC[ protected
210.T0(A)(3}-Lighting far A/C in attic
�
ZSO.S2(A)(3)-Footer stee)sha!! be used for a ground
406.8(A) - Receptacles in Damp Locatians �
�
406.8(B)(I�- Receptacies in Wet Lot�tions � �
a
410.8- Luminaires in Clothes Closets �
�
422.18- Suppart of Ceiling-Suspended (Paddle) Fans
�
1
i
;
. . . ,