� � �Co.r�stru�ti o.r� �otes
Finish floar height shal( be m9nimum S"above crown of road (City�of.2ephyrhiiis Ordinance#237)
Each bedroom shafl have at least one window sized fro emergency egress (2001 Ftorida Buiiding Code#1005.4) �
Duclwork and appliances in garage shaii be protected from physica(damage(2001 �lorida.BuitdingJMechanicai Cade
�#303,4)
Tub access shai( compiy with (2001�lorida Bu�iding/Piumbing Code#405.8)to concealed cannec4ons
Balanced return air shall be achieved through the use of transfer ducts or griifes(20Q1 F{orida Building/Mechanicai
Code#601.4) �
Window glass hazardous locations sha!! comply with {2001 Fforida Building Cade#2405.2)
Installation of gas appliances requires separate permits
200Z Nationai Electrica)Cade
210.8{A)(2)-AI(garage receptacies shaii have GFQ protteckion
Z1Q.8(A)(3)-Aii outside recept�cles shall have GFC[protectian
�
210.8(A)(6)-Ali receptacles serving countertops in the kitchen shatl be GFQ pratected
210.11(C)(3)- Bathroom circuits sha11 have no other ovtlet�
210.12(B)-A!I outfets (receptacles, lights, smoke detectars) in dwefiing bedrooms shall be AFQ protected
210.7Q(A)(3)- Light9ng for A/C in attic
ZS0.52(A)(3) -�Foater steel shaH !ae used far a ground
406.8(A)-,�Receptaefes in Damp Loeatians
406.8(B)(i)-Receptacies in Wet Locations :
410.8- Luminaires in Clothes Closets -
422.18- Support of Ceiling-Suspended (Paddle) Fans