HomeMy WebLinkAbout7320 HIGHLAND LOOP � I
,� Ele�ric�1 Not+�s
, 2�►t?2 El��ctri+��l Ca�d�
Ryr�an �onst�u�t�an
' Lot �� Hightand L�aap
;
�
210.8(A): , � All 125-volt, single-phase, 15-and 2d-arnpere receptacles installed zn the lacations
specified in(1)through(8}sha11 have ground-fault circuit-interrupter pratectzon far
� personne].
�
(3)Outdoors �
i
; (6)Kitchens—where the receptacles aze installed to serve the cournertap surfaces
�
21011(G}�3}: In addition to the number of branch circuits required by othar parts of ttus section,at least
� ane 24-ampera branch circuit shall be provided ta supply the bathraom receptacle
outlet(s). Such circuits sha11 have no other outlets.
Exceptian: Where the ZD-ampere circuzt suppdres a single bathroom, outlets for ather
equipment within the same bathraom shall be permitted to be suppXied in accordance
with 210.23(A).
21U.12(B): All branch circuits that supply 125-volt,single phase, 1S-and 20-ampere outlets
� (REdCEPTACLES,LIGHTS,S10�IOIC�DETECTORS)installed in dwelling unit
bedraoms shall be pratected by an arc-fault circuit interrupter listed ta pravide protectian
ofthe entire branch circuit.
240.24{B : Each occupant shatl ready access to all overcurrent devices pratecting the conductors
,
� supplying that accupancy.
' 210.52(A�(1): Receptacies shall be installed so that na poirrt measured horizontaliy along the flaor line
� � in any wall space is more than 1.8 m(6 ft)from a receptacle outtet.
�
�
210.52(B}{l}: In the kitchen,pantry,breakfast roozn,dining raom,or similar area of a dwelling unit,the
� two ar znare 20-ampere srnall-applianae branch circuits required by 210.11{C)(1)shall
serve all receptacle outlets covered by 210.52(A)and(C)and receptacle outlets for
refrigeration equipment.
, 2S 0•S2(C)(1): A receptacle outlet shall be installed at each wall ccsunter space that is 3Q4 mm{12 in.)or
wider.Receptacle outlets shall be installed so that no point alang the wall line is more
than 600 mm(24 in.)measured horizontally from a receptacle outlet in that space.
210.52(C)(3): At least one receptacle outlet shall be installed at each peninsular counter space with a
' � ' long dimension of 600 mrn(24 in.}or geater and a short dimension of 300 mm(i2 in.)
; � ar greater A peninsular countertop is measured from the cannectzng edge.
�
� 214,52(E): �or a one-famrly dwelling and each unit af a two-family dwelling that is at grade level,at
� least one receptacle autlet accessib�e at grade level and not mare than 2.0 m(6'h ft)
iabove grade shall be installed at the front and back af each dwelling.
� �
�
� -
� a�e�.�/�a
� �.g:sz��
,
��
'
� i
� � � Ele�trical Notes
, 2002 Electrical Code
� Ryman Construction
Lot #3 Highland Loop
210.52(�:� I In dwelling units, hallways of 3.0 m(10 ft)or more in length shall have at least one
� receptacle outlet.
� I
As used in this sub-section,the hall length shall be considered the length along the
� centerline of the hall without passing through a doorway.
250.50: If available on the premises at each building or structure served, each item in
, i 250.52(A)(1)through(A)(�shall be bonded together to form the grounding electrode
' system
� 406.8(A): � I A receptacle installed outdoors in a Iocation protected from the weather or in other damp
� i locations shall have an enclosure for the receptacle that is weatherproof when the
� receptacle is covered(attachment plug cap not inserted and receptacle covers closed).
406.8(B)(1):' 15-and 20-ampere, 125-and 250-volt receptacles installed outdoors in a wet location
I shall have an enclosure that is weatherproof whether or not the attachment plug cap is
inserted.
� • ,
• I
�
I
' I
I � I
�
I
,I
I
�
i �
� , � 09/19/02