� 21011(C)(3): In addition to the number of branch circuits
required by other parts of this section, at least one
�� 20-ampere branch circuit shall be provided to
� I supply the bathroom receptacle outlet(s). Such
- � circuits shall have no other outlets.
,, ,
I, ', Exception: Whe�e the 20-ampere ci�cuit supplies
�� �� a single bathroom, outlets fo� othe� equipment
', within the same bath�oom shall be pe�mitted to be _
; supplied in accordance with 210.23(A).
� 'I210.52 �A 1 : Rece tacles shall be installed so that no oint
, ,� )� ) p p
� '� � measured horizontally along the floor line in any
: i
� wall space is more than 1.8 m (6 ft) from a
� i receptacle outlet.
,