Loading...
HomeMy WebLinkAbout16-17904 CITY OF ZEPHYRHILLS -� 5335-8TH STREET • �si3��so-oozo 17 4 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL � PERIIeIIIT INFORMATION �LOCATION INFORMATION Permit�:17904 Issued: 11/10/2016 Address: 37826 PRAIRIE ROSE LP LT 66 Permit�ype: GENERAL BUILDING PERMIT ZEPHYRHILLS, FL. Class o Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range: Propos�d Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Fee�: Est. Value: Book: Page: , Cost: I 191,711.52 Total Fees: 9,310.42 Subdivision: WALNUT GROVE TOWNHOMES �, Amoun� Paid: 9,310.42 Date Paid: 11/10/2016 Parcel Number: 15-26-21-0210-00000-0660 � CONTRACTOR INFORMATION OWNER INFORMATION Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD MOBILE HOME SRV INC I Addr: 4209 GALL BLVD Address: 38930 BUTTERFIELD LN ' ZEPHYRHILLS, FL 33542 ZEPHYRHILLS, FL 33542-1677 � Phone: (813)377-7395 Lic: Phone: Wo k Desc: CONSTRUCT NEW TOWNHOME 1,872 SQ FT I APPLICATION FEES � � I DI G EE 859.28 ELECTRICAL FEE 214. 3 PL MBIN FEE 114.60 MECHANI�AL FEE 80.22 SEWER CONNECTION RESIDEN" 2,010.00 WATER CONNECTION RESIDENI 641.00 WATER M�TER RES 3/4" 473.78 FIRE PLAN REVIEW FEES 114.20 POLICE IMPACT FEE 254.00 FIRE IMP CT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES TOWNHOMES 769.56 TRAFFIC I PACT FEE 99% 3,445.20 TRAFFIC IMPACT FEE 1% 34.80 1 V� � � i�Or� - � Ins ections Re uired� OTER 2ND ROUGH PLUMB MIS NSULAT O C ILI FOOTER�OND DUCTS INSULATED SEWER MISC. ROUGH E ECTRIC LINTEL MISC MISC. 1ST ROU�H PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLA SHEATHING MISC. MISC. ' CONSTR CTION POLE FRAME MISC. � MISC. REINS ECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local overnment shall impose a fee of four times the amount of the fee imposed for the initial inspection or fi t reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTIC : In addition to the requirements of this permit, there may be additional restrictions applicable to this properly that may b found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Wa ning to owner: Your failure to record a notice of commencement may result in your paying twice for impr vements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." ' Comp ete Plans,Specifications and Must Accompany Application.All work shall be pertormed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. � I �� � � ONTRACTO S SIGNATURE PERMIT OFFI , PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED �� PROTECT CARD FROM WEATHER , �� � Townhome-37826 Priarie Rose Lp 1872 sq ft- Bailey Construction �, -�v�(� r�i�d#tsection � r� c�d � / � o umn SQ. FEET PRICE MAIN OR LIVING: 1,872 $ 102.41 OTHER AREA UNDER ROOF: _ $ gg pp I� OTHER: - $ _ VALUATION $ 191,711.52 FEE SHEET $ 764.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 859.28 ELECTRICAL: $ 214.43 PLUMBING: $ 114.60 MECHANICAL: $ 80.22 SUB-TOTAL $ 1,268.53 TOTAL $ 7,268.53 SEWER: $ 2,010.00 WATER: $ 641.00 IRRIGATION: $ - TOTAL: $ 2,651.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: $ 114.20 INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ 114.20 PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 � SUB-TOTAL $ 5,060.86 PARK IMPACT FEES $ 769.56 SIF'S: N/A 100.0% $ - 1.0% $ - TOTAL: T 1 F'S: $ 3,480.00 99% $ 3,445.20 1% $ 34.80 TOTAL: $ 9,310:42 i � 15-26-21-0210-00000-0660 � Pasco County Property Appraiser Page 1 of 1 Mike Wells Pasco County Property Appraiser Data Current as Of: Weekly Archive - Saturday, November 5, 2016 ParcelID 15-26-21-0210-00000-0660 (Card: 001 of001) Classification 00 -Vacant Residential Mailing Address Property Value ' BUTTERFIELD MOBILE HOME Ag Land $0 SERVICE INC Land 38930 BUTTERFIELD LN $4,369 ZEPHYRHILLS FL 33542-1677 Building $0 Physical Address Extra Features $0 � 37826 PRAIRIE ROSE LOOP ZEPHYRHILLS FL 33542-2203 Leaal Description (First 4 Lines) ]ust Value $4,369 I See Plat for this Subdivision ASsessed (Non-School Amendment 1) $4,369 WALNUT GROVE TOWNHOUSES I PB LOT 66 54 Taxable Value $4,369 'i OR 6544 PG 1916 I Jurisdiction � Citv of Zephvrhills � _ Land Detail (Card: 001 of 001) ----�--_____—_.� — --,--- Line i Use Description Zoning��Units Type � Price Condition; Value 1 I 0100 SFR� MPUD � 2,750.00 � SF j $1.56 1.00 j $4,290 — _.___�,-_ -- 2 j 0100 SFR ; MPUD � 1,570.00 � SF � $0.05 1.00 ( $79 Additional Land Information Acres 0.10� Tax Area 30ZH � �ode X iResidential Codei WGTHLPI I Building Information - Use 00 - Unimproved (Card: 001 of 001) Unim roved Parcel 00 - Unim roved Extra Features Card: 001 of 001 -----__ )____-- ---- _ Line�_i`_1� Description m-�-�--Year __�_ Units �_� �Value _ No Extra Features Sales Historv Previous Owner: N/A �-- ------r-�._—�__.____-; _-�--------- Month/Year Book/Page � Type DOR Code Condition Amount �� 08/2005 6544 / 1916 f Warranty Deed � Vacant $600,000 ---______ -___- -- - ------___T-�I _ 11/1981 � 1157 / 1702 { Vacant $130,000 ----01/1973 4�0707/ 0675�-j-J'�-- `--�� ------�� Vacant � $0 —� � http://appraiser.pascogov.com/search/parcel.aspx?parce1=2126150210000000660 11/9/2016 i ! ; 1 ��;. ', ���7d� 'lte�S�P 4'�►� !S B � ��SaA�i�� t� " " Permit Na. / ��� � Date Permitted�7�� Bu'Ider Name/Owner Name ���{( (,���L��� Cantrol# Ca nty Parce! No. 1�J- �.�- {�7,�fd--� �(�(�ubDiv: �����'� Ad resslLocation ���1�������'�- /�--�� �� ���� C! ssificationCType of Use �GG�'I''i����'- � I TR NSPQRTATlON 1MPAGT FEE Rate: Sq Ft Unit: /i�`7� �, Ex mpt ❑ Yes ❑ No How Determined � ' tm�act Fee Amount $ �r �1�0 � Zone Na. TAZ: SG C30L IMPACT FEIE Ac�ount (056) Single-Family Detached Hause Amount $ r�'.�� `� (057� Mobile Home (058} Other Residential 123) Coilection Fee Ex mpt [] Yes ❑ Na Haw Determined PA�tKS AND RECREATICIN FEE Lat�d Accourtt Land Credit Land Total Re reation Accounk Recreation Credik Recreation Total Zo e TQTAL AMOUNT $ `7 �f�'-�� Ex mpt [] Yes ❑ No How Qetermined LI RARY FEE La d Account Land Credit Land Total Fa�ility Account Facility Credit �acility Tota! Ex mpt ❑ Yes [] Na How Determined Total Amount � RE'�SOURCE FEE ERU TO�TAL AMOUNT � Pr I pared By � Checked By Rlt� CERTIFiCATE OF OCCUPANCY!lVt�L BE ISSUED QR FINAL tNSPECTIUN PERFORMED t1NT1�.THE 70TAL ANIOUNTS LlSTED HAV� ' BEERI PAID AND REGEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acl<nowledgement beiow daes nat impiy acceptance of concurrence,but slmply racelpt of a copy of this form,placing the bullding permik owner on natice of thls assessment and thQ conditions of paymant for same. �I I D E RECEIVED BY i � � R CEiPT N4. DATE BY . � . � FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Flor`da Department of Business and Professional Regulation - Residential PerFormance Method � Project N me: R1016412 Unit 8=1 and S-6 Builder Name: Buttertield Street: 4408 Court St Permit O�ce: City of Zep rhills City,Stat ,Zip: Zephyrhills,FL,33542 Permit Number / 7�� Owner: Typical-End Units 8-1 and 8-6 Jurisdiction: 611600 Design L cation: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1085.3 sqft.) Insulation Area 2. Single fa ily or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=5.0 898.67 ft2 b.Frame-Wood,Adjacent R=13.0 186.67 ftZ 3. Number f units,if multiple family 1 c.N/A R_ g= 4. Number f Bedrooms 3 d.N/A R= ftz 5. Is this a orst case? No 10.Ceiling Types (1435.0 sqft.) Insulation Area 2 a.Under Attic(Vented) R=30.0 1435.00 ft 6. Conditio ed floor area above grade(ft� 1435 b.N/A R= ft' Conditio ed floor area below grade(ft�) 0 c.N/A R= ftz 11.Ducts R ft' 7. Windo (137.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:ah 6 175 a. U-Fa tor: Dbl,U=0.30 137.00 ftz SHG�: SHGC=0.25 b. U-Fa�tor: N/A �= 12.Cooling systems kBtu/hr Efficiency SHG� a.Central Unit 27.8 SEER:14.00 c. U-Fa�or N/A ft2 I SHGG�: 13.Heating systems kBtu/hr Efficiency d. U-Fa tor: N/A ft' a.Electric Strip Heat 27.3 COP:1.00 SHG� : Area W ighted Average Overhang Depth: 1.672 ft. Area W ighted Average SHGC: 0.250 14 Hot water systems 8. Floor T pes (1435.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF.0.970 a.Slab- n-Grade Edge Insulation R=0.0 1435.00 ftZ b. Conservation features b.N/A R= ftZ None c.N/A R= ftZ 15.Credits CF,Pstat GlasslFl orArea: 0.095 Total Proposed Modified Loads: 44.53 pASS Total Baseline Loads: 46.69 I hereby ertify that the plans and specifications covered by Review of the plans and ;���.�"�'��,� this calcu ation are in compliance with the Florida Energy specifications covered by this �.� � �,, ��.;.�, . .^ Code. ��'� calculation indicates compliance �r,� � ;�;r �. �i,� s_s=_r with the Florida Energy Code. �rrf, , ��� ::��,��-"s,�. PREPA ED BY: Before construction is completed "' � 10-25-16 �' �., .fi��;.� ... ..�- � DATE: this building will be inspected for � 1;;��;� compliance with Section 553.908 � -.� g v I hereby rtify that this building, as designed, is in compliance Florida Statutes. ,,� ,�,,. with the lorida Energy Code. ��'Li�'x'�'� OWNE AGENT: BUILDING OFFIC�AL: DATE: DATE: ' - Compl�ance requires certification by the air handler unit manufacturer that the air handler enc sure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compli nce requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test rep rt in accordance with R402.4.1.2. 10/25/2�16 2:01 PM EnergyGaugeO USA-FfaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 I � , � . • FORM R405-2014 � PRQ.3ECT Title: R1016412 Unit 8-1 and 8-6 Bedrooms: 3 Address Type: Street Address 8ui(ding�ype: User Conditioned Area: 1435 Lot# Owner: Typical-End Units 8-1 and 8- Total Stories: 1 Block/SubDivision: #of Unit�. 1 Worst Case: Na PlatBaok: Buiider hiame: Butte�eld Rotate Angle: 0 Street: 4408 Court St Permit O�ice: City of Zephyrhills Cross Ventilation: No County� Pasco Jurisdic#i�n: 811840 Who[e House Fan: No City,State,Z9p: Zephyrhi3ls, Family T�pe: Single-family FL, 33542 NewlExi�ting: New(From Ptans) Commer�t: � � CC.tMATE f IECG Design Temp lnt Design Temp Heating Design Daily Temp �f Design Location TMY Site Zone 97.5% 2.5°lo Winter Summer Degree Days Moisture Range F�,Tampa FL_TAMPA INTERNATI 2 39 99 7Q 75 645.5 54 Nledium ( B�ocKs Numb�r Name Area Volume . 1 Enf9re Hause 1435 11480 ( SpACEB Numb�r Name Area Valume Kitchen Occupants Bedrooms Infil ID Finished Caoled Heated 1 Master Bedroom 220 1760 IVo 2 1 1 Yes Yes Yes 2 Mtit 19 152 No 0 1 No Yes Yes 3 Master Bath 93 744 No 0 1 No Yes Yes 4 Mwic 99 312 No 0 1 No Yes Yes 5 Kitchen 156 1248 Yes 0 1 No Yes Yes B Bedroom3 150 124Q No 1 1 1 Yes Yes Yes 7 ah 12 96 No 0 1 No Yes Yes 8 Laundry 40 320 Na 0 1 Yes Yes Yes 9 Bath2 44 352 No 0 1 Yes Yes Yes 10 Bedraom2 131 1048 No 1 i 1 Yes Yes Yes 11 Entry 58 464 No 0 1 Yes Yes Yes 12 Hali 79 632 No 0 1 No Yes Yes 13 Great Rm Dining 394 3152 No 0 1 Yes Yes Yes FLOORS � # Floar Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Master Bedroom 30.7 ft 0 220 ft' ____ 0 1 � 2 Slab-On-Grade Edge Insulatia Mtlt 1 ft 0 19 ftZ ____ 0 1 0 3 Slab-On-Grade Edge lnsulatia Master Bath 4 ft 0 93 ft2 ____ 0 1 0 4 Slab-On-Grade Edge lnsulatio Mwic 1 ft 0 39 ft2 ____ Q 1 d i 1 Ql2512�16 2:01 Pt�tl EnergyGaugeQ USA-F}aRes2014 Section R445.4.9 Compiiant Soffware Page 2 of 5 � - FORM R4 5-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab-On-Grade Edge Insulatio Kitchen 1 ft 0 156 ftZ ____ 0 1 0 6 Slab-On-Grade Edge Insulatio Bedroom3 14 ft 0 150 ft2 �_ 0 1 0 7 Slab-On-Grade Edge Insulatio ah 1 ft 0 12 ftz _� 0 1 0 8 Slab-On-Grade Edge Insulatio Laundry 1 ft 0 40 ft2 _�_ 0 1 0 9 Slab-On-Grade Edge Insulatio Bath2 1 ft 0 44 ft2 _� 0 1 0 10SIab-On-Grade Edge Insulatio Bedroom2 23.7 ft 0 131 ftz ____ 0 1 0 11SIab-On-Grade Edge Insulatio Entry 5 ft 0 58 ftz �_ 0 1 0 12Siab-On-Grade Edge Insulatio Hall 1 ft 0 79 ft2 ____ 0 1 0 13SIab-On-Grade Edge Insulatio Great Rm Dining 39 ft 0 394 ftz ____ 0 1 0 ROOF � Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Coior Absor Tested Tested Insul. (deg) 1 Hip Composition shingles 1512 ftZ 0 ftZ Medium 0.65 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1435 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Master Bedroom 30 Blown 220 ftZ 0.1 Wood 2 Under Attic(Vented) Mtit 30 Blown 19 ft' 0.1 Wood 3 Under Attic(Vented) Master Bath 30 Blown 93 ftZ 0.1 Wood 4 Under Attic(Vented) Mwic 30 Blown 39 ftz 0.1 Wood 5 Under Attic(Vented) Kitchen 30 Blown 156 ft' 0.1 Wood 6 Under Attic(Vented) Bedroom3 30 Blown 150 ft' 0.1 Wood 7 Under Attic(Vented) ah 30 Blown 12 ftz 0.1 Wood 8 Under Attic(Vented) Laundry 30 Blown 40 ftZ 0.1 Wood 9 Under Attic(Vented) Bath2 30 Blown 44 ft2 0.1 Wood � 10 Under Attic(Vented) Bedroom2 30 Blown 131 ft2 0.1 Wood 11 Under Attic(Vented) Entry 30 Blown 58 ftz 0.1 Wood 12 Under Attic(Vented) Hall 30 Blown 79 ft' 0.1 Wood I 13 Under Attic(Vented) Great Rm Dining 30 Blown 394 ft2 0.1 Wood �� 10/25/2 16 2:01 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 3 of 5 � • FORM R405-2014 WALLS I Adjacent Space Cavity Width Height Sheathing Framing Solar Belo o ! , - _ 1 N Exterior Concrete Block-Ext In�rh�ster Bedro 5 8 0 8 0 64.0 ftZ 0 0 0.3 0 'I 2 E Exterior Concrete Block-Ext In�hster Bedro 5 14 8 8 0 117.3 ftZ 0 0 0.3 0 ' 3 S Exterior Cancrete Block-E�In��ster Bedro 5 S 0 8 0 64.0 ftZ 0 0 0.3 0 4 N Exterior Concrete Block-F�ct Ins�edroom3 5 14 0 8 0 112.0 ft' 0 0 0.3 0 5 N Exterior Concrete Block-Ext Ins�edroom2 5 11 8 8 0 93.3 ft2 0 0 0.3 0 6 W Exterior Concrete Block-Ext Ins�edroom2 5 12 0 8 0 96.0 ftZ 0 0 0.3 0 I _ 7 W Exterior Concrete Block-Ext Insul Entry 5 5 0 8 0 40.0 ftZ 0 0 0.3 0 8 N Exterior Concrete Block-Ext In�leat Rm Din 5 25 0 8 0 200.0 ft2 0 0 0.3 0 9 E Exterior Concrete Block-Ext In�'mleat Rm Din 5 14 0 8 0 112.0 ftZ 0 0 0.3 0 _10 N Garage Frame-Wood Entry 13 11 8 8 93.3 ftZ 0.23 0.01 0 _11 N Garage Frame-Wood Bath2 13 6 4 8 50.7 ftZ 0.23 0.01 0 _12 N Garage Frame-Wood Laundry 13 5 4 8 42.7 ftZ 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated Entry None .35 3 6 8 20 ftz 2 E Insulated Great Rm Din None .35 3 6 S 20 ftz 3 N Insulated Laundry None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. / � Wall Overhang \� Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening p E 2 TIM Low-E Double Yes 0.3 0.25 30.0 ftZ 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 2 N 4 TIM Low-E Double Yes 0.3 0.25 15.0 ftZ 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 �i N 5 TIM Low-E Double Yes 0.3 0.25 15.0 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 � W 6 TIM Low-E Double Yes 0.3 0.25 20.0 ft� 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 N 8 TIM Low-E Double Yes 0.3 0.25 15.0 ftZ 1 ft 0 in 0 ft 9 in Drapes%blinds Exterior 5 6 N 3 TIM Low-E Double Yes 0.3 0.25 30.0 ft� 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 p E 9 TIM Low-E Double Yes 0.3 0.25 12.0 ftz 8 ft 8 in 1 ft 2 in Drapes/blinds Exterior 5 I GARAGE # FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 263.9 ft' 384 ftZ 64 ft 8 ft 1 INFILTRATION # S�ope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholiehouse Proposed ACH(50) .000254 956.7 52.52 98.77 .1906 5 10/25/2016 2:01 PM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 4 of 5 s • ' � FORM R40,5-2014 HEATING SYSTEM # System Type. Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP�1 27.3 kBtu/hr 1 sys#1 COOLING SYSTEM I# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 14 27.8 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM �# System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None �ione ftZ DUCTS � —Supply-- --Retum-- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft' Attic 75 ftz Default Leakage ah (Default) (Default) 1 1 TEMPERATURES Program �ble Thermostat:Y Ceiling Fans: Coolin r ]Jan [ ]Feb r lMar A r Ma X Jun [X]Jul �X]Au rX]Se Oct Nov Dec Heating [X]Jan [X]Feb [X]Mar ��Apr � �May � ��un [ ]Jul [ ]Aug [ ]Sep ��Oct �X�Nov Dec Venting [ ]Jan [ ]Feb [X]Mar Jun [ ]Jul [ ]Aug [ ]Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule T.pe 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(W ) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(W H) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(W ) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 � 66 Heating(W�H) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 II 10/25/20 6 2:01 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 5 of 5 . ' a ; • ' FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the EnergyPerformance Index,the more efficient the home. 4408 Court St, Zephyrhilis, FL, 33542 1. New con truction or existing New(From Plans) 9. Wali Types insulation Area � 2. Single fa ily or multiple family Single-family a.Concrete Block-Ext Insul,EMerior R=5.0 898.67 ftZ b.Frame-Wood,Adjacent R=13.0 186.67 ft 3. Number f units,if multipie family 1 c.N/A � R= ft' 4. Number f Bedrooms 3 d.N/A R= ft' 10.Ceiling Types Insulation Area 5. Is this a orst case? No a.Under Attic(Vented) R=30.0 1435.00 ft2 6. Conditio�ed floor area(ftZ) 1435 b.N/A R= ft2 7. Window�" Description Area c.N/A R= ft2 a. U-Fa or: Dbi,U=0.30 137.00 ft' 11.Ducts R ft' a.Sup:Attic,Ret:Attic,AH:ah 6 175 SHG : SHGC=0.25 b. U-Fa tor: N/A ftZ SHG�: 12.Cooiing systems kBtu/hr Efficiency c. U-Fa tor: N/A ft' a.Central Unit 27.8 SEER:14.00 SHG�: ' d. U-Fa tor: N/A ft' 13.Heating systems kBtu7hr Efficiency SHG�: a.Electric Strip Heat 27.3 COP:1.00 Area We ghted Average Overhang Depth: 1.672 ft. Area We ghted Average SHGC: 0.250 8. Floor Ty es Insulation Area 14.Hot water systems Cap:40 gallons a.Slab- �n-Grade Edge Insulation R=0.0 1435.00 ftZ a.Electric EF.0.97 b.N/A R= ft2 b. Conservation features c.N/A R= ft2 None 15.Credits CF,Pstat I certify th t this home has complied with the Florida Energy Efficiency Code for Building ��_.�,���,�� Construct�n through the above energy saving features which will be-installed (or exceeded) ,�, , �� �.y in this hom�e before final inspection. Otherwise, a new EPL Display Card will be completed ��"�„'�'�' `�=z��'s',s��, based on installed Code compliant features. �- r+��t��'�%. �� .�,•° ,,� � +ei! _„_1 G . fi�� ,,.�. �` fs+; _ ..�� i Builder Signature: Date: � `�� � n�� . , Address o New Home: City/FL Zip: ��r ��`* �OD�E"�" . "Note This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1;492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For inforrrSation about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. ' **Lab I required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/2 /2016 2:02 PM EnergyGaugeO USA-FlaRes2014 -Section R405.4 1 Compliant Software Page 1 of 1 . . .. �F . . l� � Manuai S Compliance Report Job: R1016412 -�1- v�rrightsoft" Date: 10-24-16 I Entire House BY: rMN Bahr's Propane Gas �AC Inc . 4441 Allen�2d,Zephyrhills,FL33541 Phone:813782-5013 I � • ' � • For: Typical- End Units 8-1 and 8-6 4408 Court St, Zephyrhiils, FL 33542 � • • • o , Desig Conditions Out oor design DB: 91.0°F Sensible gain: 19409 Btuh Entering coil DB: 79.2°F Out oor desigr.WB� 76.0°F Latent gain: 4824 Btuh Entering coil WB: 64.3°F Indo r design DB: 75.0°F Total gain: 24233 Btuh Indo�r RH: 50% Estimated airflow: 927 cfm � � Manu acturer's Performance Data atActual Design Conditions E ui mentt e: S IitAC q YP P Man acturer: Tempstar or Eqv. Model: N4A330A(G)KC'`+FXM4X30""A* � Actual airflow: 927 cfm Sen�ible capacity: 20850 Btuh 107% of load Late t capacity: 6950 Btuh 144% of load ' Tota capacity� 27800 Btuh 115% of load SHR: 75% � � • ' Desig�n Conditions Outdoor design DB: 41.OoF Heat loss: 16460 Btuh Entering coil DB: 66.8°F Indo r design DB: 70.0 F Manu acturer's PerFormance Data atActual Design Conditions Equipment type: Elec strip Man�facturer: Model: Act�al airflow: 261 cfm Out ut capacity: 8.0 kW 166% of load Temp. rise: 96 °F Meet are all requirements of ACCA Manual S. , 20160ct-25 14:06:39 � � wrightsoft' Right-Suite�Universal 2017 17.0.09 RSU07440 Page 1 � .. QuadPlex-4408 Court St\R1016412 Unit&1.rup Calc=MJ8 Building Front faces: W Pro ect Summa Job: R1076412 -�- v right�oft� � � Date: 70-2416 Entire House By: TMN Bahr's Propane Gas &AC Inc 4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013 � • ' • • For: Typical- End Units &1 and 8-6 4408 Court St, Zephyrhills, FL 33542 Notes: Load Calculation was obtained from an on-site inspection. � - � � • Weather: Lakeland Co(S), FL, US Winter Design Conditions Summer Design Conditions •utside db 41 °F Outside db 91 °F I side db 70 °F Inside db 75 °F esign TD 29 °F Design TD 16 °F Daily range M Relative humidity 50 % Moisture difference 47 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing $tructure 13081 Btuh Structure 12283 Btuh Qucts 3379 Btuh Ducts 5710 Btuh entral vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh umidification 0 Btuh Blower 1416 Btuh iping 0 Btuh quipment load 16460 Btuh Use manufacturer's data y I Rate/swing multiplier 1.00 Infiltration Equipment sensible load 19409 Btuh ethod Simplified Latent Cooling Equipment Load Sizing �onstruction quality Average ireplaces 0 Structure 3550 Btuh Ducts 1274 Btuh • Heating Cooling Central vent(0 cfm) 0 Btuh �rea(ftZ) 1435 1435 Equipment latent load 4824 Btuh olume(ft') 11480 11480 ,ir changes/hour 0.45 0.23 Equipment total load 24233 Btuh Equiv.AVF(cfm) 86 44 Req.'total capacity at 0.75 SHR 2.2 ton Heating Equipment Summary Cooling Equipment Summary ake Make Tempstar or Eqv. �rade Elec. Heat Trade TEMPSTAR Model Cond N4A330A�G)KC* AHRI ref Coil FXM4X30 A* AHRI ref 3692289 fficiency 100 EFF Efficiency 11.5 EER, 14 SEER , eating input 8.0 kW Sensible cooling 20850 Btuh �eating output 27297 Btuh Latent cooling 6950 Btuh emperature rise 96 °F Total cooling 27800 Btuh ctual air flow 261 cfm Actual air flow 927 cfm ir flow factor 0.016 cfm/Btuh Air flow factor 0.052 cfm/Btuh tatic pressure 0.50 in H20 Static pressure 0.50 in H20 pace thermostat Load sensible heat ratio 0.80 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ,` wri t�tsoft" 20160ct-25 14:06:39 � Right-SuiteCSl Universal 2017 17.0.09 RSU07440 PaBe� � .. QuadPlex-4408 Court St\R1016412 Unit&1.rup Calc=MJB Building Front faces: W � ' i _ -F�k-w��ightso�° Right-JCJ Worksheet •1aq: R1016412 Entire Hvuse Date: ,o-xa-,s By: TMN Bahr's Propane Gas &AC Inc Q441 AtteniRd,Zephyrflit(s,FL33541 Phone:813782-5013 1 ftoom name Entife House Master Bedroom 2 Expr�sed wal! 112.3 ft 30.7 ft 3 Rasm height 8.4 ft d 8.d it heaticool 4 Ropm dimensions 14.7 x 15.0 ft 5 Raam area 1435.0 ft2 72D.0 ftz Ty Construction U-value Or NTM Area {ft�} �oad Area (ft�} �o� number (Btuh/ft�°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Goai Gross NIP1S Heat Cooi �ross NlFiS Heat Cooi 6 i 13A-5ocs 0,125 n 3.63 2.22_ 469 394 1429 8T7 64. 64 232 142 � 4A5-2ob 0.540 n 15,66 12.07 "15 0 235 181 , 0 0 0 0 4A5-2ab 0.540 n 35.66 92.07 � 60 ' 0 940 724 0 0 Q d �3A-5ocs 0.125 e 3.63 2.22 229 1&7 606 372 i17 87 3T7 194 11 I I 4A5-2ob 0.540 e 15,66 12.p7 12 12 188 145 0 0 0 0 4 D 4A5-2db p.540 e 95.66 30.39 30 0 470 912 30 0 470 972 � 9'INO 0.35D e T0.95 90.15 20 20 204 204 0 0 0 0 W 13A-5ocs 0:125 s 3.63 2.72� 64 64 232 142 64 64 232 142 13A-5ocs p.125 w 3.63 2.22 136 96 348 213 0 0 0 0 u D 4AS2ob 0.540 w 15.66 3p.39 20 0 313 608 0 0 0 Q 11N0, 0.350 w 14.15 90.15 2� 20 204 204 0 0 4. 4 12C-Osw 0.091 - 2.8�1 1.28 187 169 4A& 277 0 0 0 A 11N0 � • 0.350 n 10.15 10.75 18 � 18 : 181 181 D p 0 0 C 16B-30ad 0.032 - 0.93 1.68 1435 1435 i332 2411 ?20 ?20 244 37� F ' 22A-tpI., 4,989 - 26.8$ 0.00 1435 t12 3222. 4 22Q 31 , 880 0 6 c) ED�cutsion 0 165 Et�elope loss/gain 10350 7392 2334 1926 92 a)� infiltration 2732 770 746 2i0 b) Roam vec�tilaiion D Q 0 0 13 irrt�mal gains: Occuparits @ 230 4 920 2 460 Apg}iancestotlzer 3200 0 Su� otal(lines 6 to 13) 13081 12283 3080 2596 L � extemal taad 0 0 4 0 e�s transfet 0 0 0 0 Redistribution 0 0 0 0 14 Su�btotal 13081 122$3 3080 2596 - 15 Dt�Gt loads 26°l0 46°l0 3379 5790 26°ta 46°l0 796 12D7 T al room load 16460 17993 3875 3803 � Ai�required(cfm) 261 927 61 196 Calculations a roved b ACCA to meet ali re uirernents of Manuai J 8th Ed. �„�^� wrTightso�FC" zo1&Oct-2514:os:3s Right-Suite�Universal 2017 17.0.09 RSU07440 Page 1 QuadPlex-�1408 Court St1R1016412 Unit&1,rup Calc=MJB 6uilding Front faces: W _ +��}-wi•i�htseft° Right-J RO Wor'k�heet Job: R1016412 Entire House Date: 10-24-16 By: TMN � Bahr's Propane Gas 8�AC Inc 4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013 1 Ro�m name Mtlt Master Bath 2 Exposed wall 0 ft 0 ft 3 Ro�m height 8.0 ft heat/cool B.0 ft heat/cool 4 Room dimensions 3.3 x 5.7 ft 1.0 x 93.1 ft 5 Room ar� 18.9 ft� 93.1 ft� Ty Construction U-value Or HTM Area (ft� Load Ar� (ft� Load number (Btuhlft?°F) (Btuhlft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool ' 6 I, 13A-Socs 0:125 n 3:63. 2.22 0 0 0 0. 0 0 9 . ,_ 0 � 4A�2o6 0.540 n 15.66 12.07' 0 0 0 0 0 0. 0 0 4AS2ob 0,,540 .n 15.66 12.07 „ 0' 0 0 0 0 � 0; 0 0 W I 13A-5ocs 0.125 e 3.63 2.22 0 0 0 0 0 0 0 0 11 � 4A5-2ob 0.540 e 15.66 12.07 0 0 0 0 0 0 0 0 4A�2ob 0.540 e 15.66 30.39 0 0 0 0 0 0 0 0 11N0 0.350 e 10.15 10.15 0 0 0 0 0 0 0 0 W` 13A-5oc5 0.125 s 3.63 2.22 0 0 0. 0 0 0 0 ` � 0 13A-Socs 0.125 w 3.63 2.22 0 0 0 0 0 0 0 0 4A5-2ob 0.540 w 15.66 30,39 0 0 0 0 0 0 0 0 11N0. 0.350 w 10.15 10.j5 0 0 0 0 0 0 0 0 I 92GOsw 0.691 �- 2.64 1.28 0 0 � 0 0 ' 0 ' 0: - D 0 11N0 0:350 ' ri 10.15 � 10.15 0 0 0 b 0 0 0 0 C 16B-30ad 0.032 - 0.93 1.68 19 19 18 32 93 93 86 156 F zzA-ta , o:sss - . za.ss: o.� - �s o 0 o ss o: o. o ' , i 6 c)AED excursion -1 -7 EnVelope loss/gain 18 30 86 149 12 a) Irdiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Int mal gains: Occupants @ - 230 0 0 0 0 Appliances/other 0 0 SuDtotal(lines 6 to 13) 18 30 86 149 L�s extemal load 0 0 0 0 L s transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18 30 86 149 15 Ductload5 26% 46% 5 14 26% 46% 71 69 T ai room load 22 44 109 219 Ai�required(cfm) 0 2 2 11 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �-F�- wr�gtstsoft" 201GOct-25 14:06:39 Right-Suite�Universal 2017 17.0.09 RSU07440 Page 2 QuadPlex-4408 Court St\R1016412 Unit 8-1.rup Calc=MJ8 Building Front faces: W - -t�#-onrr°,�ntso�r• Right-JO Worksheet Job: R1016412 Entire House Date: 10-24-76 By: TMN Bahr's Propane Gas 8�AC Inc 4441 Allen�d,Zephyrhills,FL33541 Phone:813782-5013 1 Room name Mwic Kitchen 2 Exposed wall 0 ft 0 ft 3 Roofn height 8.0 ft heaUcool 8.0 ft heaUcool 4 R dimensions 5.3 x 7.3 ft 1.0 x 155.6 ft 5 Ro�o n ar� 39.1 ft' 155.6 ft' Ty Construction U-value Or HTM Ar� (ft� Load Ar� (ft� Load number (Btuhlft�°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 I 13A-5ocs 0.125' n -3.63 222 0 0 0 0 0 0 0. � 0 4A5-2ob �:540 n. 15.66 . 12.07 0 0 0 0 , 0 0 b 0 I 4A5-2oti � ,0.540 n-, 15.66 12.07 0 0 0 0 0 0. 0, 0 11 �111���/// 13A-5ocs 0.125 e 3.63 2.22 0 0 0 0 0 0 0 0 4AS2ob 0.540 e 15.66 12.07 0 0 0 0 0 0 0 0 4A5-2ob 0.540 e 15.66 30.39 0 0 0 0 0 0 0 0 11N0 0.350 e 10.15 10.15 0 0 0 0 0 0 0 0 W ', 13A-5ocs 0125 s. 3,63 , 2.22 0 0 0: 0 0; 0 ' 0 0 13A-5ocs 0.125 w 3.63 2.22 0 0 0 0 0 0 0 0 4A5-2ob 0.540 w 15.66 30.39 0 0 0 0 0 0 0 0 11N0. 0.350 w 10.15 10.15 0 0 0 0 0 0 0 0 12GOsw• ,, 0:091 - 2:64 1;28_ 0 0 0 0 0• 0 0 ' 0 11N0 . - 0:350 n 10:15 10.15 � "0 0 0 0 0 0" ` 0 0 C 16B-30ad O.D32 - 0.93 , 1.68 39 39 36 66 156 156 144 261 F 2?A-tp► ' 0:989 - 28.6$ 0.00 $9 0 0: 0 156 0 � 0 b. 6 c A D excursion -3 -92 ) Envglope loss/gain 36 63 144 170 12 a) Irdiitration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Inte gains: Occupents @ 230 0 0 0 0 Appliances/other 0 18oD Su otal pines 6 to 13) 36 63 144 1970 Less extemal load 0 0 0 0 Les�transfer 0 0 0 0 Redistribution 0 0 0 0 14 Su otal 36 63 144 1970 i 15 Du loads 26% 46% 9 29 26% 46% 37 916 � Tota room load 46 92 182 2885 Air r uired(cfm) 1 5 3 149 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. � � wrightso�#Cc 2o1�Oct-2514:06:39 �� Right-Suite�Universal 2017 17.0.09 RSU07440 page 3 ..QuadPlex-4408 Court St1R1016412 Unit&1.rup Calc=MJ8 Building Front faces: W I . •F�t-w�•ightsof� Right-JO Worksheet Job: R1016412 Entire House Date: 10-24-16 By: TMN I Bahr's Propane Gas�AC Inc 4441 Allen Rd,Zephyrfiills,FL33541 Phone:813-782-5013 1 R�m name Bedroom3 ah 2 Exposed wall 14.0 ft 0 ft 3 Room height B.0 ft heaUcool 8.0 ft heaUcool 4 Robm dimensions 1.0 x 150.2 ft 3.3 x 3.7 ft 5 Room ar� 150.2 ft� 122 ft' , Ty Construction U-value Or HTM Ar� (ft� Load Area (ft� Load number (Btuhlft�-°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 . 19A-Socs D.125 n 3.63 � 2.71 112 97 � 352 216 0 0 0. ,0 4A5-2ob, 0.540 n 15.66 . 12:07 " 0 0 .0 0 0 0 0 ' 0 � 4A&2ob 0.540 n 15.66' 12.07 15 0 235 �, 181 0 0 0 0 13A-5ocs 0.125 e 3.63 222 0 0 0 0 0 0 0 0 11 � 4A5-2ob 0.540 e 15.66 12.07 0 0 0 0 0 0 0 0 � 4A5-2ob 0.540 e 15.66 30.39 0 0 0 0 0 0 0 0 11N0. 0.350 e 10.1_5 10.15 0 0 0 0 0 0 0 0 W 13A-5ocs' 0.125 :s 3.63 2.22 0 � � 0. 0 0 0 . U 0 � 13A-5ocs 0.125 w 3.63 2.22 0 0 0 0 0 0 0 0 � 4AS2ob 0.540 w 15.66 30.39 0 0 0 0 0 0 0 0 11N0 0.350 w 10.15 10.15 0 0 0 0 0 0 0 0 12GOsw 0.091 -- -2'64 1.28 � 0 0. � 0= � 0 0 0. 0 0 11NQ 0:350 n' 10.15 10.15� , 0 0 0 0 0 0 0. 0 C , 16B-30ad 0.032 - 0.93 1.68 150 150 139 252 12 12 11 21 F � 27A-tp 0.989 - 28.68 0.00 150 14 402. 0 12 0 . ;0. 0 6 c)PED excursion �3 -1 E elope loss/gain _ 1127 606 11 20 12 a) Ir�filtration 340 96 0 0 b) Room verrtilation 0 0 0 0 13 Ir�temal gains: Occupants @ 230 1 230 0 0 � Appliances/other 0 0 S�btotal(lines 6 to 13) 1468 932 11 20 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 R istribution 0 0 0 0 14 S btotal 1468 932 11 20 15 Dtjctloads 26% 46% 379 433 26% 46% 3 9 ' Total room load 1847 1365 14 29 - Ai�required(cfm) 29 70 0 1 Calculations a roved b ACCA to meet all re uirements of Manual J 8th Ed. W�� ��p�. 2016-Oct-2514:06:39 � � Right-Suite�Universal 2017 17.0.09 RSU07440 Page 4 QuadPlex-4408 Court St\R1016412 Unit&1.rup Calc=MJB Building Front faces: W • +�-wr�,�htsot�- Right-JO Worksheet Job: R1016412 , I Entire House Date: 10-24-16 By: TMN Bahr's Propane Gas �AC Inc 4441 Alien Rd,Zephyrhills,FL33541 Phone:813782-5013 1 Room name Laundry Bath2 2 Exposed wall 0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1 0 x 40.4 ft 8.3 x 5.3 ft 5 Room ar� 40.4 ft� 44.4 ft2 Ty Construction U-value Or . HTM Area (ft� Load Ar� (ft� Load number (Btuh/ft?°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N!P/S Heat Cool Gross WP/S Heat Cool 6 � 13A-Socs � 0.125 n; 3,63 222 , 0 0 D: 0 0 0: 0 0 4A5-2ob 0.540 ri 15.66 12.07 0 0 0 0 0 0 0� 0 � 4AS2ob 0:540 n 15.66 42.07 0 0 ,0 0 0 0 0. 0 11 �VVV���lll 19A-Socs 0.125 e 9.63 2.22 0 0 0 0 0 0 0 0 4AS2ob 0.540 e 15.66 1207 0 0 0 0 0 0 0 0 4A�2ob 0.540 e 15.66 30.39 0 0 0 0 0 0 0 0 11N0 0.350 e 10.15 10.15 0 0 0 0 0 0 0 0 W I 13A-5ocs .. 0:125 s,_ 3:63. 2.22 0 0 0 0. 0 0 0 0 � 13A-5ocs 0.125 w 3.63 2.22 0 0 0 0 0 0 0 0 i 4A�2ob 0.540 w 15.66 30.39 0 0 0 0 0 0 0 0 11N0 0.350 w 10.1,5 10.15 0 0 0 0 0 0 0 0 R ' � 12GOsw ' 0:091 •- 2.64 1.28 b3 43 113 55 51 51 134 . 65 � �D 11N0_ ' 0:350 n 10.15 1D.15 0 0 0 0 0 � 0 0 `0 C 16B-30ad 0.032 - 0.93 1.68 40 40 38 68 44 44 41 75 F ' 224-t(� 0.989 _�- : 28.6$, 0.00 40 : ;. 0 0_ 0 . 44 _ 0 0. 0 6 c)�ED excursion -28 -6 � Envelope loss/gain 151 95 175 '133 12 a) Irfiiltration 0 0 0 0 b) Room ventilffiion 0 0 0 0 13 Inte� gains: Occupants @ 230 '0 0 0 0 � Appliances/other 500 0 Subtotal pines 6 to 13) 151 595 175 133 Les extemalload 0 0 0 0 � Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 151 595 175 133 15 Ductlo3ds 26% 46% 39 277 26% 46% 45 62 TotaI room load 189 872 220 196 Air fequired(cfm) 3 45 3 10 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ��^ wric,,,�htso�#^ 20160ct-25 14:0639 � Right-Suite�Universal 2017 17.0.09 RSU07440 Page 5 ..QuadPlex-4408 Court St\R1016412 Unit&1.rup Calc=MJ8 Building Front faces: W � � � . • -F�I-wrightsoft° Right-JO Worksheet Job: R1016412 Entire House Date: 10-24-16 By: TMN Bahr's Propane Gas 8�AC Inc 4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013 1 Ro�m name Bedroom2 Entry 2 Exposed wall 23.7 ft 5.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 RoOm dimensions 1.0 x 130.7 ft 5.0 x _11.7 ft 5 RoQm ar� 130.7 ftZ 58.3 ft� Ty Construction U-value Or HTM Area (ft� Load Ar� (ft� Load number (Btuh/ft�°F) (Btuhlft� or perimeter (ft) (Btuh) w perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 V�! I' 13A-5ocs � ,,0:125 n 3:63 2.22 93 78 284 174 0 0 0 0 �_1_G 4Ar2o6 ' 0.540 n 15.66 12.OZ 0 0. b 0 0 0 0� 0 � .-�G 4A54ob . ,0.540 n 15.66 12.07 15 0 235. 181 0 0 0 . 0 11 I 13ASocs 0.125 e 3.63 2.22 0 0 0 0 0 0 0 0 4AS2ob 0.540 e 15.66 12.07 0 0 0 0 0 0 0 0 � � 4A�2ob 0.540 e 15.66 30.39 0 0 0 0 0 0 0 0 11N0 0.350 e 10.15 10.15 0 0 0 0 0 0 0 0 W 13A�ocs 0.]25 s. � .3.63 2:22 '0 0 0 0 0 0 0 0, �N 13A-Socs 0.125 w 3.63 2.22 96 76 276 169 40 20 72 44 �,r 4A�2ob 0.540 w 15.66 30.39 20 0 313 608 0 0 0 0 L�D 11N0 0.350 w 10.15 10.15 0 0 0 0 20 20 204 204 q � 12GOsw 0i091 - 2.64 1.28 0 0 0 . 0 93` 75 199 �97 �--D 11N0 0.350 n 10.15 10.15 0 0 0 0 18 18 181 189 C 168-30ad 0.032 - 0.93 1.68 131 131 121 220 58 58 54 98 F 22A-tpt 0.989 � -' 28.68 - p:00 �39 24 679 , 0; 58 ,_ 5 143 0 6 c)�EDexcursion 195 -29 E velope loss/gain 1908 1547 854 595 12 a) Infiltration 57g �� �� 34 b) Room ventilation 0 0 0 0 13 Irrtemal gains: Occupents @ 230 1 230 0 0 � APPlian�es/other 0 0 S�7btotal(lines 6 to 13) 2483 1g39 976 629 L�s extemal loed 0 0 0 0 L�s transfer 0 0 0 0 Redistribution 0 0 D 0 14 Subtotal 2483 1939 976 629 l5 Duc[loads 26% 46% 641 902 26% 46% 252 293 - T9tai room load 3125 2841 1228 922 Ai required(cfm) 50 146 19 48 Calculations a roved b ACCA to meet all r uirements of Manual J 8th Ed. .� "�' wriglltso'Ft' Right-Suite�Universal 2017 17.0.09 RSU07440 2016-Oct-25 14:06:39 ,� Pa�ge 6 � QuadPlex-4408 Court St\R1016412 Unit 8-1.rup Calc=MJ8 Building Front faces: W I e � � � . -F�-wrigt,tsa�t• Right-JO Worksheet Job: R1016412 Entire House Date: 10-2416 By: TMN Bahr's Propane Gas �AC Inc 4441 Allen�2d,Zephyrhills,FL33541 Phone:813-782-5013 1 Roqm name Hall Great Rm Dinirg 2 Exposed wall 0 ft 39.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heaticool 4 Rodm dimensions 1.0 x 79.1 ft 1.0 x 392.9 ft 5 Roqm ar� 79.1 ft' 3929 ftz Ty Construction U-value Or HTM Ar� (ft� Load Ar� (ft� Load number (Btuhlft'°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 I 13A�acs 0,125 n 3.83 2.22 0 � 0 0 2� 155 562 345 4A�2o6 ` 0.540 n 15,66 12.07 0, 0 0 U 15 0 235 181 4A5-2ob � 0:540 n 15.66 12.07 0 0 0 0 30 � 0 � 470 � 362 18A-5ocs 0.125 e 8.68 2.22 0 0 0 b 112 80 280 178 11 ' I 4AS2ob 0.540 e 15.66 12.07 0 D 0 0 12 12 188 145 • 4AS2ob 0.540 e 15.66 30.39 0 0 0 0 0 0 0 0 11 NO_ 0 350 e 10.15 10.15 0 0 0 0 20 20 204 204 W, 13fi�5ocs 0.]25 .s. 3,63 2.22 0 0 0: 0 . 0 :0 0 ' A V1J 13A-5ocs 0.125 w 3.63 222 0 0 0 0 0 0 0 0 �.G 4AS2ob 0.540 w 15.66 30.39 0 0 0 0 0 0 0 0 ��D 11N0_ 0.350 w 10.15 10.15 0 0 0 0 0 0 0 0 � 12GOsw, 0.091 - 2.64. 1.28. 0 0 0- ._ 0 , 0 0 0 0 11N0 0.350 ' n: 10.15 10.15 0 ' 0 0 0 - 0 0 0 0 C 16B�Oad 0.032 - 0.93 1.68 79 79 73. 133 393 393 365 660 F ,� 22A-tp�. � __ 0.989 -_ 28.68. 0.00 � 79 0 0: 0 393 , 39. 1119. 0 6 c)AED excursion -8 -�q4 En elope loss/gain 73 127 3431 1931 12 a) Irdiltration 0 0 948 267 b) Room ventilation 0 0 0 0 13 Int�mal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 900 Suqtotal Qines 6 to 13) 73 127 4380 3098 Less extemal load 0 0 0 0 Les�s transfer 0 0 0 0 Rec�istribution 0 0 0 0 14 Su�otal 73 127 4360 3098 15 Du tloeds 26% 46% 19 59 26% 46% 1131 1440 Tot�l room loed 92 186 5511 4538 Air�equired(cfm) 1 10 87 234 I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. I wrig�ftsoft• zots-Oct-2514:os:3s �� Right-Suite�Universal 2017 17.0.09 RSU07440 Page 7 . QuadPlex-4408 Court St\R1016412 Unit 8-1.rup Calc=MJB Building Front faces: W , J