Loading...
HomeMy WebLinkAbout16-17926 � I CITY OF ZEPHYRHILLS I , 5335-8TH STREET i (sis)�$o-0020 17926 ' BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION - "� LOCATION-INFORMATION Permit#:17926 Issued: 11/29/2016 Address: 36060 CARRIAGE PINE CT Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. ' Class o�Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Fee�: Est. Value: Book: Page: Cost: � 252,110.70 Total Fees: 11,331.69 Subdivision: SILVERADO Amount Paid: 11,331.69 Date Paid: 11/29/2016 Parcel Number: 04-26-21-0070-00100-0090 ` � CONTRACTOR INFORMATION _ OWNER INFORMATION Name: P R HORTON INC Name: DUNE FL LAND I SUB LLC C/O HAWK Addr: 12602 TELECOM DR Address: 2502 N ROCKY POINT DR STE 1050 AMPA FL 33637 TAMPA FL 33607-5995 Phone:� Lic: Phone: 813-549-1968 Wo�k Desc: NEW SINGLE FAMILY HOME 2,238 SQ FT ( 3 BED/2 BATH) I � APPLICATION FEES � �� B ILDINGiFEE 1,045.93 ELECTRICAL FEE 213.08 PLUMBING FEE 142.05 MECHANICAL FEE 99.44 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfd 1% 48.28 TRAFFIC IMPACT FEE 99% 3,595 TRAFFIC IMPACT FEE 1% 36.32 � � ' '�'� I ���� �U - -- -_ ��` �v �1 � � � � � " Ins ections Re uired - " FOOTER I 2ND ROU H P UMB MIS INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. - 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLA� SHEATHING MISC. MISC. CONSTR i CTION POLE FRAME MISC. MISC. REINS ECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local ,�overnment shall impose a fee of four times the amount of the fee imposed for the initial inspection or fir�t reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may b�found in the public records of this county, and there may be additional permits required from other governmental � entities such as water management, state agencies or federal agencies. � "Wa'rIIning to owner: Your failure to record a notice of commencement may result in your paying twice for impr6vements to your properly. If you intend to obtain financing,consult with your lender or an attorney � before recording your notice of commencement." Comp ete Plans,Specifications and Must Accompany Application. All work shall be performed in accordance � with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. I NO OCCUPANCY BEFORE C.O. O A�--'� � ONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO , CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER I � i � . � � i D R HORTON INC-36060 CARRIAGE PINE CT-2,238 SQ FT o umn SQ. FEET PRICE ! MAIN OR LIVING: 2,238 $ 112.65 � OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - � VALUATION $ 252,110.70 FEE SHEET $ 947.00 ADDRESS $ 40.00 � DRIVEWAY $ 40.00 BUILDING: $ 1,045.94 ELECTRICAL: $ 213.08 PLUMBING: $ 142.05 MECHANICAL: $ 99.44 SUB-TOTAL $ 1,500.50 TOTAL $ 1,500.50 SEWER: N/A WATER: N/A IRRIGATION: $ - TOTAL: $ - WATER METER: N/A IRRIGATION METER $ - I FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL � TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 ' 5% $ 26.35 'i TOTAL: $ 553.35 SUB-TOTAL $ 2,053.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 I! TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 , 1% $ 36.32 � TOTAL: $ 11,331.69 I I � ' [�l�l��Z� ��u�-� ��� �"D ; � . � BOUNDARY & AS-BUILT SURVEY I DF_SCRIPTION:(AS FURNISHED) � LOT 9, BLOCK 1, SILVERADO RANCH SUBDIVISION PHASE 2, 3 & 4 AS RECORDED IN PLAT BOOK 73, PAGE(S) 59-65, OF 7HE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. i I � ,`� ���R7 I CARR�AGE,��,`�t�,N�Y e��E��C� /�� C2 ��\ i� -_�- � y u a�y PG -� i z �B�pµGl '� j$� & ("" N74'�9�� 1 � o /� � � ——� 1'= 30' �f1 GRAPHIC SCALE � � 0� 1� \o �� ��� — � —�� ,�� G Q � I ����L� ��' ,'���—�,'_ 1&6� �"��g�Q Z o � 1,,s LOT 10 ��\4 n �� �ao o a o BLOCK 1 ',� y ..s o b � �Ha�ra+ (7!� a�rmie V' gO1R0 F � J W GLrw/ lmY� Ra�ue DdW pard BeQin7 Chord W r�°'�uF rf�e�og• W (,j� � �lAq�^,,;���� ed � p 47.83' 320.00' B�4'SY 57838'S8'W 47.89� � �, ��j,TP`�'� m Cl 247.BH' 550.00' �034'4Y N852YOYW 24274' � / GS 52�3' 35Q00' E'34'SY 576J8'S81Y 3238' Z � �O� ,$ 1 � G 7BSA8' 350.00' 3139'W' NB7�'38'W 187.93' B��C� Llne Table y m Zg,� 1Q0, LYi�/ D4Mbn �gih �,0� 'o L1 M4�930'E 2653' ! N �pT 9 � o g���K�c� . 8�13 »w 52•Da� — — —I — S�4'�9'30 � � 5 , I / ` g�OCK � I I \ I FOR THE BENEFIT AND \ i EXCLUSIVE USE OF: D�R�HOH111N'� n6N�ca=�u` LEGEND: —— CQiIERIINE Q ---- RlfiiT OF WAY IINE FIXRA NIs.u1D UISC DRNNACE FlDW �/1013 NOTES: � oosro�c�v�naw p ���z•ueor�Roo u�c�w 1. PROPERTY CORNERS SHOWN HEREON WERE �/c NR caaninoam (p) p�p�,T SET/FOUND ON 12-19-16,UNLE55 OTHERN75E SHOWN. pC pppT pF qIRVANRE ;� ��E PCC ppplT pp�pyppUND CURVE 2.THE SURVEYOR HAS NOT ABSTRACIED THE LAND rca pwu�i ca�7ROL PqNT SHOWN HEREON FOR EASEMENIS,RIGHT OF WAY, �w ���B�W� ri Pourt av e�mrs�CnON RESTRIC710N5 OF RECORD WHICH MAY AFFECT hiE � ��N����9�� PK PARKQt KALON TITLE OR USE OF THE LAND. � ���P'� rnc roR77 a�a7nve � ���� Pp. POINT ON IINE C CONQtETE WM1C PRC POMT OF RlVFRg WRVANRE 3. NO UNDERGROUND IMPROVEMENTS FiAVE BEEN .EW.A.FIDeRIu aQtcacv W�lUCEYENT AGENCY ppy pptNANEN7 REFERENCE MONUYENT LOCAIED E%CEPT AS SHOWN. F.I.R.Y. ROOD IN9IRANCE RAIE YM p� pppF�pNAL SURVEYOR AND YAPPQt ID IDENTIFlCAlION p7 ppQ.(T OF TµCQlCY 4. ALL DIMENSIONS WERE VERIFlED IN 7HE FlELD � V��BUSINFSS � ���E� AND SHONN UPON THIS DRAN1NG. � �����'�'� s/q gp�y� D6UE ORA@U1GE d UTILI7Y EAS�AQIT 5.ELEVATIONS ARE BASED ON PASCO PDE PRIVA7E DRAM���mENT � ��TM P� PUE PUBLIC UTILITY EAS�@17 COUNTY BENCHMARK g P 678, ELEVATION 99.82'NAVD x�w NOR1H AYERIGN VER7ICAL D�M1 1988 DATUM. NCYD NAIIONAL GEODE7IC YERTICAL DAMI �HEREBY CERTIFY,THAT THIS SURVEY,SUBJECT TO THE SURVEYOR'S NOTES CONTAINED HEREON FLOOD NOTE: MEETS 7HE APPLICABLE'MINIMUM TECHNICAL I H�ve ouwNm n�E F.I.R.w.caauraTr u�a N0.121otcoa2�, STANDARDS'SET FORTH BY 7HE FLORIDA 60ARD DA7ED D9-28-14,AND FOUND 7HE SIBJECT PROPQtTY APPEARS 70 OF PROfES90NAL SURVEYORS AND MAPPERS IN LIE IN ZONE%,AREA OIJISIDE 7HE 100 FEAR FLOOD PWN.7!ff CHAPTER SJ-17, RORIDA ADMINISTRATIVE CODE SURVE1roR YAKES NO WMAN7EE5 AS 70 7HE ABOVE p1FORYA710N. PURSUANT TO CHAPTER 472027, FLORIDA PLEAg CONTACT 7ME LOfJ1L F.EY.A AGQIT FOR VER61CA710N. STATUIES. ��q9itnllYsignttl6ylamnW Bokman BEARING BASIS; "°�`�x�O1�d'• BEARINGS 3fOX41 HEttEON ARE BASFD OH 71ff COITERINE OF ,�4� '� da�Ammran CMRIAGE PPlE CWRT BE1NG N7��8'30'E,PER PLAT. o w+es,m=W��esW A M E R 1 CA N �w,{ � �,"""" (Fl�oon�:l 12-19-76 R��: - �-ino�=n.ma„� � S U RV EY 1 N G � "`°'" . � -01e:�,�.a,�OflO&25 ,W„ SG1LE 1��30 FEEf !r SnD' � 8c M AP P I N G I N C. �pMES W.BOLEMAN PSM#6485 0"� nvaaovEoeY: CER7IFlCA710N OF AUlHORIZATION NUMBFR LB/8793 THIS BOUNDARY&AS-BUILT SURVEY IS 16W12 LOT 9,6LOQC 1 3191 MAq11RE BOULEVARD,SUIIE 200 NOT VALID H77HWT THE AU7HEN71C �oe No. ORLANDO,FLORIDA 32803 ELECTRONIC SIGNANRE AND 7HE AU7HEN71C FOR�BOARD 01-OJ-17 CC (AW)428-7879 ELECTRONIC SEAL OF A FLORIDA LICQlSED oanwner; DSB a�o7 xwN to Ys e cF WWW,AGERICANSURVEItNGIwnuMPING.0011 SURVEYOR AND MAPPER. G��2016nB\1609�160912 SIWERADO RANC1f PII 2.3,4LPLOT ftAN�SURVElS\I609121OT 9 6lR I.dwg I f s * i �. ` ' Q-_ - :. .,y-. ,l:Y£ � �� �./,i"�ri:��� .. •.. � i.j� `F�.,�� .1'-' _ i ��x:r. `�'p:' }.. �,,� y. � ��, ,,. ; ` City af Zephyrhills BUTLDING PLAN REVIEW COMMENTS ! � � � ���� Cantract�r/Hameawner: �,�r �`-�'C C�..._ I DateReceived: t� ' �f`-�l� � Site: � , ���11 �i � (_...l2!'C'� ` �� , � ,l,,,, , �� �,`� Permit Type: �f r �' � � � 2�=-� .�Z � � Appr�oved wlno comments:❑ Approved w/the below comments``�.. Denied w/the below comments: ❑ � � .,� ,.—.--� � . , .. � � � , � ! I � � I � ; This ca �ent sheet shall be kept with the per�nit anc3/or plans. _ � l �l� ��_��* Pr p�ans Exarniner Date Cou actor or Homeowner ��,{, � {Required when camments are present) � � i � � � � � Illllllllflllllllllllilllllllllllllllllillllllllllllllllllll � i \ 2016188024 I � li � ' n � Pertnit No. Parcel ID No �N�,l10����7'(J�0�I��wl D li NOTICE OF COMMENCEMENT State o(� ��0 rl �1__ County of PQS CJ.J � THE UI�DERSIGNED hereby gives nodce that improvement will be made to cedain real property,and in accordance with Chapter 713,Florida SlaWles, Ihe followmg informalion is provided in this Notice of Commencement: �� 1. Descrlption of Property Parcel Iden110cation No. Streel Address: � � � � G I, � 2. I General Descripdon of Improvement �'Q� S t/1�l ��. rC�V1/1�i I� ��i(l P►1�.P 3. I Owner Informallon or Lessee infarmation i/lhe Lessee contracted for the improvement: II, �. G�• r�c,n Tn c, ' ' 1 Z(�2"�°'Q.I���M 1�r ��u�c� ��3�.3� �� i Address (� C Cily� State j Interest in Property: 1�e 2 �li M t�(2 �� W Y � Name of Fee Simple Tilleholder: �,Z U � W pf different from Owner Iisted above) ���f�y.� .�J W U � 4. Contracfor �• �• F'I�Z'�[]/� �/�l9 C«y Slate �gy, Z U � � �O � [�CD�.Came�2IeC,oM �r ��IMI�Q 33�� �L � � � F— � a W Address CI State � � w z a ConVactors Telephone No. � � r � � � ) � � �d Q � 5. Surely�__[S/� � W � � U U Name � _ � �� � a3 Address City Slate U a � � � � Amount of Bond: $ �r� Telephone No.. 2 U U z J � 6. Lender. � � ~ J ¢ U Name`��� � V- W � z O J Address City Slate � � � � 2 Q � Lendefs Telephone No. � � O Q }, p Z Ci S � 7 Persons withln lhe Slate of Florida designated by lhe owner upon whom nolices or olher documents may be served as provided by � � z � � � Section 713.13('I)(a)(�,Florida Statutes: � /� LL1 � Q J W Q IelQi/�'CL� 1'7r9��P_ I— — W � z � Name �( � � � r = � z � Q >- �z�o o,2 -�'�.ler� `�r ��,,�,//c� � � D���- � � �- � o � a m Te eph� one Number of Designaled Person: ���— ���—�17�Z0 State 8. •Z In addition to himself,1he owner designates �Z�/7 of �Q�4� � � lo receive a copy of Ihe Lienors Nolice as provided in Seclion 713.13(1)(b),Florida Stalutes. '� � •� 1Q' � Telephone Number of Person or Entily Designated by Owner �� � m � a �, � 9. Expiration dete ot Nolice ot Commencement(lhe expiration date may nol be before the complelion of conslruction and final payment to lhe �e ,.�, h� ',a�� � contractor,but wiil be one year(rom the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFfER THE EXPIR.4TION OF THE NOTICE OF COMMENCEMENT j �� .�� cd� m � ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13 FLORIDA STATUTES, AND CAN � • � '''���� RESULT IN YOUR PAYING TNICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE a �' . C,y � ��'1 Q � RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT � �'i � � WITH YOUR LENDER OR AN ATfORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT � `' * Under penalty of perjury,I declare that I have 2ad the foregoing notice of commencement and that the facts staled lherein are true lo the best � • ��� Iof my knovAedge and belief. �� � ` STAT OF FLORIDA p� •� � COUNTI'OF PASCO � Sign ure o Owner or Lessee,or Owners or Lessee's Aulhorized Rep!:1I818552 Ree: 10.00 Office irectodPaAnedManager' DS: 0.�0 IT: 0.00 f1�f � �fP+�,L � I / � 11/29/2016 J. R., Dpf.y Clerk t-� � —����ln '��/1�- Signatory's Title/Office The foii going instrument was acknowledged hse�fjore me Ihis�day oLy�(��20�by I�1�i C I� 1�A(��� �1 �r_as '�� �Olf�L1 CC✓�/ (type of authority�,e.g.,oKcer,lrustee,allomey in faci)for �� � . . •rJ Or TUII Z/1 l�_ (nam�e�Jo,f,p rty on bebalf of whom in�trument was executed). Personally Known�O�3F Produced Identification❑ Notary Signature�S�L��� C.�� '��h�X�Gc�t/ i Type II Identiflcalion Produced Name(Print) (9"ff'i�i N( ' ������ � PRU� 5 0'NEIL,Ph D PpSCO CLERK B COMPTROLLER �� Notary pudk SfaW Ot FIO�da 11/29/201�J 01:25 m 1 f 1 • G��M�onahue � BK 9�6� �0�� MYCwnmfe�bnFF77pt7p PG �'+aw� �aQe.�vienoie i ` wpdal cs/noticecommencement,yc053048 � I -- � - -- -- '-'-- �---'-- -- — I � -- —� - �i C � a � �: PASC�? �C)U�VTY, �'LC>RI�A �� � ,� .. .. ��iTTtit�10. ! 1 �G-A! � Date Permitted t!-/8-l� � Builder Name/0wner Name � �. ?Y7�l1 ��C.� Control# ' Caunty Parcel No. Q�Z�i-�1-'OD`70--f�D 1OCS''���ID SubD�v: cS;t ih'�'GtGpO AddresslLocation ��L?�ZT �n''ric.cte... 'r'�`n� �,'j � ClassificatianiType af Use �% ^�m� �Gl TRANSPORTATION 1MPACT FEE Rafe: Sq Ft Unit: 2.r 2-3� � Exempt �Yes ❑ No How Determined �I Impact Fes Amount 3(��2.OQ Zone Na. TAZ: I I SCHdOL IMPACT FEE � Account (056} Single-Family Detached House Amount $ �, �'7�- 2�j � {05T) Mobile Home (q56� Other Residential 123) Collection Fee Exempt (� Yes ❑ (Vo How Qetermined PARKS ANd RECREATtON FEE , i Land Account Land Credit Land Total �i Recreation Account Recreation Credit Recreation Tota! Zone Tt?TAl.AMOUNT $ rf.�9,j(�u Exempt [� Yes ❑ No Haw Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total ' Exempt ❑ Yes ❑ No Flaw Defermined Total Amount .� RESQURCE FEE ERU � TOTAL AMOUNT '� Prepared By Checked By NO CERTIFiCATE OF OCCUPANCY WILL BE ISSUED C?R FINAL INSPEG7lC?N pERFORMEU UNTIL THE T()TAL AMOUNTS LlSTED HAVE BEEN PAlD AND RECEIPTEd FOR 8Y A CENTl2AL PERMl771NG QFFlCE OF PASCO COt1NTY Acknowledgsment below doea nat lmply aocepfanca of concurrence,6uE simpiy receipt of a copy of tfiis form,placing the bullding parm(t owner on notice of Rhis assessmant and thQ canditions of payment far same. I I DATE RECE{VED BY RECElPT NO. DATE BY I ______ . _. s : , . , o FORM R405-2014 FLt�RIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION � �lorida Department of Business and Professional Regulation - Residential Pertormance Method Project Name` Aria Elevation D Builder Name: DF{}�{-E� mes `Ip� ��`�� Stree�: ���� �f`�'i �,�Ine ��- Permit Office: �,;�f� ��Yrhr�� i City,State,Zip: Zephyrhills,FL, '/ Permit Number: /'� y� Owne�r. S� `�/ ts✓ Jurisdiction: (> ( 1 !p 4 o I Desig�Location: FL,Tampa � County:: �h ) Pt�� II 1. Newlconstruction or existing New(From Plans) 9. Wall Types(1658.2 sqft.) Insulation Area �� a.Concrete Block-Int Insul, Exterior R=4.1 1372.20 ft2 2. Sing�e family or multiple family Single-family b.Frame-Wood,Adjacent R=11.0 286.00 ftz 3. Nu i ber of units,if multiple family 1 c.N/A R= ftz 4. Nu ber of Bedrooms 3 d.N/A R= ftz ' � 10.Ceiling Types (1672.0 sqft.) Insulation Area 5. Is th's a worst case? No a.Under Attic(Vented) R=30.0 1672.00 ftz 6. Conl�itioned floor area above grade(ftz) 1672 b.N/A R= ftz z Conlditioned floor area below grade(ftz) 0 11 cDucts R R ftz 7. WinIrrl Iows(182.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 392 a. Ui Factor� Dbl, U=0.34 142.00 ftz S�I1HGC: SHGC=0.31 ' b. U-Factor Dbl, U=0.55 40.00 ft2 12•Cooling systems kBtu/hr Efficiency c. ��HGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 -Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. �-Factor N/A ftz a.Electric Heat Pump 28.6 HSPF:8.20 HGC: Area Weighted Average Overhang Depth: 4.985 ft. Area Weighted Average SHGC: 0.317 14.Hot water systems S. Flo I r Types (1672.0 sqft.) Insulation Area a.Electric Cap:50 gallons a.S�ab-On-Grade Edge Insulation R=0.0 1672.00 ftz b. Conservation features EF:0.950 z b.N{A R= ft None c.NI(A R= ftz 15.Credits Pstat I GIasS/Floor Area: 0.109 Total Proposed Modified Loads: 48.45 pASS II Total Baseline Loads: 57.14 I herelby certify that the plans and specifications covered by Review of the plans and ��'SKE��'qT� this c i Iculation are in compliance with the Florida Energy specifications covered by this � ,f , ' = � , O�, �.� ,�a;,� Code i calculation indicates compliance r,� �i,, '� = .�` � wi t h t he F lori da Energy Co de. ti rr�r,r�'��.",`�.:%�•�;:�.��=';� O� PREPARED BY: � Before construction is completed -�i'�' � � __=r�',_ ._.. � DATE: 1 -�-�� this building will be inspected for � i.w�° compliance with Section 553.908 * ° ,� I here��y certify that this building, as designed,is in compliance Florida Statutes. .� 5 � , with ti e Florida Energy Code. COD�'�� OWf�ER/AGENT� BUILDING O FIGtAL: DATE: DATE: ` ii - Co I pliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as ce ified factory-sealed in accordance with R403.2.2.1. -Co pliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test r1 ort in accordance with R402.4.1.2. P 1 0/28/201 6 8:11 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4 � j � . � � FO �M R405-2014 � FL;�RIDA ENERG.Y EFFICIENCY CODE FOR BUILDING CONSTRUCTION � f=lorida Department of Business and Professional Regulation - Residential Performance Method � . - Project Name: Aria Elevation D Builder Name: DRH Express Homes Street: ���D �`r; �,����e Gt.- • Permit Office: City,State,Zip: Zephyrhills,FL,5�� Permit Number. Own �r: �/ ✓ Jurisdiction: Desi�n Location: FL,Tampa �-f' County:: Hillsborough(Florida Climate Zone 2) II i 1. Ne i construction or existing New(From Plans) 9. Wall Types(1658.2 sqft.) Insulation - Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1372.20 ftz � b.Frame-Wood,Adjacent R=11.0 286.00 ftz 3. Nu ber of units,if multiple family 1 _ c.N/A R= ftz d.N/A 4. Nu I ber of Bedrooms 3 R= ftz 5. Is tFi s a worst case? No 10.Ceiling Types (1672.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1672.00 ftz 6. Conl itioned floor area above rade ftz 1672 b.N/A R= z 9 ( ) ft z Con itioned floor area below grade(ftz) 0 c.N/A R= ft 11.Ducts R ftz 7. Windows(182.0 sqft.) Description Area a.Sup:Attic, Ret:Main;AH:Main 6 392 a. U Factor Dbl,U=0.34 142.00 ft2 S GC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ftz 12.Cooling systems kBtWhr Efficiency S GC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 c. Ui Factor: N/A ftz S� GC: 13.Heating systems kBtu/hr Efficiency d. U Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20 S GC: Area Weighted Average Overhang Depth: 4.985 ft. Area Weighted Average SHGC: 0.317 14.Hot water systems � a.Electric Cap:50 gallons 8. Floo Types (1672.0 sqft.) Insulation Area EF:0.950 a.SI b-On-Grade Edge Insulation R=0.0 1672.00 ftz b. Conservation features b.N%� R= ft2 None - �'N i R- ftZ 15.Credits Pstat Glass/Floor Area: 0.109 Total Proposed Modified Loads: 48.45 pASS I Total Baseline Loads: 57.14 I here ly certify that the plans and specifications covered by Review of the plans and ��TIiE ST,q this c culation are in compliance with the Florida Energy specifications covered by this -� = �p Code. calculation indicates compliance ,��`,;�°o-"� '°��.� � with the Florida Energy Code. !• m„�.��•;,':Y;�'.`�',:�°„ p� PREP� RED BY: Before construction is completed w� -= .. DATE� 1 -ZS'Llo this building will be inspected for � ---�������- � compliance with Section 553.908 � * � I here certify that this building, as designed,is in compliance Florida Statutes. ,� �,S with thii Florida Energy Code. CpD.��� OWN R/AGENT• BUILDING OFFICIAL: DATE� DATE: - Com liance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certi�ied factory-sealed in accordance with R403.2.2.1. -Com�liance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage � test re ort in accordance with R402.4.1.2. 10/28 2016 8:11 AM Ener Gau e0 USA-FlaRes2014 Section R405.4.1 Com liant Softw I 9Y 9 p are Page 1 of 4 Il - + , , • ' �ORM Ft405-2014 I PROJECT � Title: Aria Elevation D Bedrooms: 3 Address Type: Lot Infarmation Building Type: llser Gonditioned Area: 1672 �ot# 911 Own r: Total Stories: 1 Block/SubDivision: Silverado #of �nits: 1 Worst Gase: Na PlatBook: Builder Name: DRH Express Nomes Rotate Angie: 0 S#reet: Perm��t Office: Cross Ventilation: Counry: Hillsborough Judstliction: Whale E{ouse Fan: City,State,2ip: Zephyrhills, Fami�, Type: Single-family FL, New/ xisting: New(From Plans) Gomr�ent: Garage L �ace N �� � CLIMATE � lECC Design Temp !nt Design Temp Heating Qesign Daily Temp Design�ocatian TMY Site Zane 97.5�Ia 2.5°la Winter Summer Degree Days Moisture Range � FL,Tampa FL TAMPA_lNTERNAT! 2 39 91 70 75 645.5 54 Medium I BLOCKS Nu ber Name Area Volume 1 BIoCk1 1672 14496.2 ( SPACES Nu ber Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 Main 1672 14496.2 Yes 4 3 1 Yes Yes Yes � FLOOF3S I # Floor Type Space Perimeter R-Value Area Tile Wood Carpet � 1 Slab-On-Grade Ecfge lnsulatio Mai� 192.68 ft 4 1672 ftz ---- 0.5 4 0.5 il ROQF � Roof Gable Roof Solar SA Emitt Emitt Deck Pitch � # Type Materiais Area Area Golor Absor. Tested Tested lnsul. (deg} 1 Hip Compositian shingles 1870 ftz 0 fi2 Dark 0.92 No 0.9 No 0 26.6 I ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC ( 1 Ful�attic Vented 300 1672 ftz Y N I � CEI�[NG � # Ceiling Type Space R-Value Ins Type Area Freming Frac 7russ Type � 1 Under Attic(Vented) Main 30 Blown 1672 ft� 0.11 Wood I 10! 8(24i6 8:11 AM EnergyGauge�USA-FlaRes24i4 Seciion R405.4.1 Compliani Saftware Page 2 of 4 � ti � . . ' FORM R405-2014 I WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1� N Exterior Concrete Block-Int Insul Main 4.0999 18 0 S 8 156.0 ftz 0 0.01 0 2 E Exterior Concrete Block-Int Insul Main 4.0999 44 0 S 8 381.3 ft2 0 0.01 0 3� S Exterior Concrete Block-Int Insul Main 4.0999 38 8 8 S 335.1 ftz 0 0.01 0 4 W Exterior Concrete Block-Int Insul Main 4.0999 57 8 8 S 499.8 ftz 0 0.01 0 5I N Garage Frame-Wood Main 11 20 0 S 8 173.3 ftz 0.23 0.01 0 _6I E Garage Frame-Wood Main 11 13 0 8 8 112.7 ft2 0.23 0.01 , 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In � 1 N Insulated Main None .4 3 6 8 20 ftz � 2 N Wood Main None .46 2 S 6 8 17.8 ft2 I WINDOWS Orientation shown is the entered,Pro osed orientation. � Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening � 1 N 1 Vinyl Low-E Double Yes 0.34 0.31 31.0 ftz 2 ft 8 in 0 ft 1 in Drapes/blinds Exterior 5 � 2 N 1 Vinyl Low-E Double Yes 0.34 0.31 2.5 ftz 7 ft 8 in 0 ft 2 in Drapes/blinds E�erior 5 � 3 S 3 Vinyl Low-E Double Yes 0.34 0.31 62.0 ftz 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5 I 4 S 3 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 8 ft 0 in 0 ft 1 in Drapes/blinds Exterior 5 � 5 W 4 Metal Low-E Double Yes 0.55 0.34 40.0 ft2 12 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 I 6 W 4 Vinyl Low-E Double Yes 0.34 0.31 15.5 ftz 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5 II GARAGE I # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation � 1 432.177 ftz 432.177 ft2 49 ft 8.67 ft 0 I INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Ilhalehouse Proposed ACH(50) .000386 1691.2 92.85 174.61 .2892 7 HEATING SYSTEM I # System Type Subtype Efficiency Capacity Block Ducts � 1 Electric Heat Pump None HSPF:8.2 28.6 kBtu/hr 1 sys#1 � I 10/ 8/2016 8:11 AM Ener Gau e�USA-FlaRes2014 Section R405.4 1 Com liant Software Pa e 3 of 4 9Y 9 P 9 1 l , . FORM R405-2014 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER:14 28.6 kBtu/hr 858 cfm 0.75 1 sys#1 � � HOT WATER SYSTEM I # System Type SubType Location EF Cap Use SetPnt Conservation � 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None I I SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF � None None ftz I - DUCTS / ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# \/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool � 1 Attic 6 392 ftz Main 40 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Prog�amable Thermostat:Y Ceiling Fans: Cooli�g Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Heati�9 �X�Jan �Feb �Mar E�APr f �May 4�Jun f�Jul f�Aug 4�SeP f�Oct �Nov �Dec Venti ]Jan Feb X Mar [X]A r [ Ma � Jun [ Jul [ Au [ Se [ Oct Nov Dec Therm¢l'stat Schedule: HERS 2006 Reference Hours Schedi�le Type 1 2 3 4 5 6 7 8 9 10 11 12 Coolini (WD) AM 78 78 78 78 78 78 78 78 80 80 SO SO PM 80 80 78 78 78 78 78 78 78 78 78 78 Coolin (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heatinl• (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heatin (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 I PM 68 68 68 68 68 68 68 68 68 68 66 66 1 0/28/201 6 8:11 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 � i ' � . , . FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) � DISPLAY CARD � ESTIMATED ENERGY PERFORMANCE INDEX* = 85 The lower the EnergyPerformance Index,the more efficient the home. , Zephyrhills, FL, 1 Ne ' construction or existing New(From Plans) 9 Wall Types Insulation Area � a.Concrete Block-Int Insul,Exterior R=4.1 1372.20 ftz ' 2. Single family or multiple family Single-family Z b.Frame-Wood,Adjacent R=11.0 286.00 ft 3. Nuriiber of units,if multiple family 1 c.N/A R= ftz 4. Nurnl ber of Bedrooms 3 d.N/A R= ftz �� 10.Ceiling Types Insulation Area 5. Is t is a worst case? No a.Under Attic(Vented) R=30.0 1672.00 ftz 6. Co�ditioned floor area(ftz) 1672 b.N/A R= ftz z 7. Win��ldows" Description Area c.N/A R= ft 2 a. U-Factor• Dbl,U=0.34 142.00 ftz 11• Ducts R ft , a.Sup:Attic,Ret:Main,AH•Main 6 392 �HGC: SHGC=0.31 b. �-Factor: Dbl,U=0.55 40.00 ftz HGC• SHGC=0.34 12.Cooling systems kBtu/hr Efficiency c. �-Factor: N/A ftz a.Central Unit 28.6 SEER:14.00 HGC• d. U-Factor: N/A ftz 13.Heating systems kBtu/hr Efficiency �HGC• a.Electric Heat Pump 28.6 HSPF:8.20 Are Weighted Average Overhang Depth: 4.985 ft. Area Weighted Average SHGC: 0.317 8. Flo¢r Types Insulation Area 14 Hot water systems , Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ftz a.Electric EF:0.95 b.f�/A R= ft2 c.N�A R= ftz b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building E Sr Constr��ction through the above energy saving features which will be installed (or exceeded) �,���� = q�'�o in this �home before final inspection. Otherwise, a new EPL Display Card will be completed y�v`,,,;''',r ==-�.. �.�, based�on installed Code compliant features. W rr,,,,�K�-:;;✓€:.�-;;�:,,�;,�a� Builde Signature: Date: � v �"����' � a * :� ' Addre s of New Home: ��� G�'�!'�Cn ; �-��ity/FL Zip: , � �. g`� T ��5�//c����� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support st�aff. "`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. i 10/28/2016 8:11 AM EnergyGaugeOO USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 I - - - I ! , � i • � F1'�RM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Buildin Performance and Prescri tive Methods ADDI�ESS: Permit Number: Zephyrhills,FL, MANGATORY REQUIREMENTS See individual code sections for full details. � 4I01.3 Energy Pertormance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy Florida law [�ection 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components i i stalled in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans a d specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. � R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. Q R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4 1 1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4 1 1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be pertormed at any time after creation of all penetrations of the building thermal envelope. During testing• 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. � Ft403.1.1 Thermostat pravision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. � II �i403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls Ilhat,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. � �403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance i�' ith Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction r rough-in testing below. uct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 53.99, Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following. I1 Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: ' 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. i 0/28/2016 8:11 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4 1 Com Page 1 of 3 I � � ' , • I • � � I FORM R405-2014 MAF DATORY REQUIREMENTS - (Continued) _ � Fl403.2.3 Buiiding Cavities(Mandatary). Building framing cavities shall not be used as ducts or plenums. ❑ f�403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insutation. � i 403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily II accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. � � F�403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have tjieat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 Yz inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. � 403.4.4 Water heater efficiencies(Mandatory). � R403.4.4.1 Storage water heater temperature controls . R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). . R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main bumer(s) of combustion types of service water heating systems to be turned off. � R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category Solar water heaters shall met the criteria Section R403.4 4.2.1. . R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar pomestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and coaling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. � R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. -� • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1 15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 10/28/2016 8:11 AM EnergyGauge�USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3 �� i , , , I . FORA� R405-2014 MAI�IDATORY REQUIREMENTS - (Continued) � R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded pertormance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for retum side gains if the return duct(s)is installed in an unconditioned space. i Exceptians: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than SO percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. � R403.6.1.2 Heating equipment capacity ' R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section � R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. . R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1 ' R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1 � R403.6.1.3 Extra capacity required for special accasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1 A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum pertormance during base load periods is utilized. I ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections I C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ IR403.8 Snow melt system controls(Mandatary). Snow and ice-melting systems,supplied through energy service to the building,shall I�, i�clude automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling � II nd an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. I ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and ilhground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy ?equirements for portable spas shall be in accordance with ANSI/APSP-14. Q R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. � R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. � R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or ' solar energy source computed over an operating season. ❑ � R404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be igh-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. � R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously buming pilot lights i � R405.2 Pertormance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. � O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 0/28/2016 5:11 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Aria Elevation D Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Tampa I� CIOMPONENT CRITERIA CHECK Ai�barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned � attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation W Ils and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Ri�n 'oists Rim joists are insulated and include an air barrier. Fl�oors (including above-garage Insulation shall be installed to maintain permanent contact with underside arjd cantilevered floors) of subfloor decking. IIThe air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or Iunconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled I by insulation that on installation readily conforms to the available cavity s aces. G��rage separation Air sealing shall be provided between the garage and conditioned spaces. R�ecessed lighting Recessed light fixtures installed in the building thermal envelope shall be �� air tight, IC rated,and sealed to the drywall. i Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Slhower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air �I barrier installed separating them from the showers and tubs. E�ectrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. � H AC regiSter boots HVAC register boots that penetrate building thermal envelope shall be Isealed to the sub-floor or drywall. Firelace An air barrier shall be installed on fireplace walls. Fireplaces shall have P �� gasketed doors 10/2�8/2016 8:11 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 J �Q��iiREss'V�_�,4 Manual S Compliance Report Dae: OctlO,zo,4 .�•.:� � Entire House Bv� _� �F ;��; � " �•�:� Progressive Air Systems ��`�4'rEM9�,P 5907�Dasher ct,Port Richey,FI34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 , �I � � ' � � For: DR Horton/ Express homes Lot 9 Blk 1 Silverado, Zephyrhills, FI • . • • • Deii ign Conditions ��utdoor design DB: 91.2°F Sensible gain: 21334 Btuh Entering coil DB: 76.1°F ��utdoor design WB: 77.1 °F Latent gain: 2877 Btuh Entering coil WB: 63.0°F I�door design DB: 75.0°F Total gain: 24211 Btuh I� door RH: 50% Estimated airflow: 1000 cfm Mal ufacturer's Performance Data at Actual Design Conditions quipmenttype: SplitASHP M, anufacturer: Carrier Model: CH14NB030"*"A+FB4CNP030 Actual airflow: 1000 cfm Sensible capacity: 23532 Btuh 110%of load �lTatent capacity: 3786 Btuh 132%of load �otal capacity: 27318 Btuh 113%of load SHR: 86% �� • � e ' De�sign Conditions �I Outdoor design DB: 40.0°F Heat loss: 20312 Btuh Entering coil DB: 69.6°F I door design DB: 70.0°F ' M II ufacturer's Performance Data at Actual Design Conditions �quipment type: Split ASHP ,�anufacturer: Carrier Model: CH14NB030'***A+FB4CNP030 ctual airflow: 1000 cfm ,Output capacity: 25625 Btuh 126%of load Capacity balance: 37 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F ackup equipment type: Elec strip �lanufacturer: Model: �bctual airflow: 1000 cfm � utput capacity: 6.4 kW 108%of load Temp. rise: 20 °F T�e above equipment was selected in accordance with ACCA Manual S. , � wri htsoft'� 2016-Oct-28 08:14:09 �� � � Right-Suite�Universal 2013 13.0.11 RSU18520 Page 1 .on\Wrightsoft Files\E�ress homes�Aria 4EAB.rup Calc=MJ8 House faces: N I ,_ .._, . jacyO I�Egs'VF9�9 Load Short Form DetC: OCt 10,2014 a Entire House Bv: ��r�� =�: u•�� Progressive Air Systems S�9+eMg.�•► 5907 iDasher ct,Port Richey,FI 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 I � • ' 0 � For: DR Horton/ Express homes Lot 9 Bik 1 Silverado, Zephyrhiils, FI i � ' � • • Htg Clg Infiltration Outside db(°F) 40 91 Method Simplified Inside db(°F) 70 75 Construction quality Semi-tight Design TD (°F) 30 16 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference(gr/Ib) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT , ake Carrier Make Carrier ,rade CARRIER Trade CARRIER � odel CH14NB030'*"A Cond CH14NB030****A HRI ref 6804001 Coil FB4CNP030 AHRI ref 6804001 fficiency 8 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 22500 Btuh Heating output 29600 Btuh @ 47°F Latent cooling 7500 Btuh '�emperature rise 27 `F Total cooling 30000 Btuh ��ctual air flow 1000 cfm Actual air flow 1000 cfm , ir flow factor 0.049 cfm/Btuh Air flow factor 0.047 cfm/Btuh tatic pressure 0 in H20 Static pressure 0 .in H20 � pace thermostat Load sensible heat ratio 0.88 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ftz) (Btuh) (Btuh) (cfm) (cfm) �M bed 237 3345 3280 165 154 dining 202 2812 3947 138 185 �reatroom 257 3318 4133 163 194 M wio 49 744 338 37 16 �rc 25 372 169 18 8 II�bath 135 1579 845 78 40 ��itchen 146 170 1547 8 73 I�aundry 42 252 843 12 40 b/C closet 14 16 25 1 1 l�ed3 154 1615 1675 80 79 �oyer 162 1679 1494 83 70 bath2 60 659 322 32 15 bed2 166 3751 2716 185 127 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. � wri htsoft`� 2016-Oct-28 08:14:09 ^� � � Right-Suite�Universal 2013 13.0.11 RSU18520 Page 1 �'� ...on\Wrightsoft Files\Express homesVlria 4EAB.rup Calc=MJ8 House faces: N _ , , i . A `_ r il Entire House d 1647 20312 21334 1000 1000 �Other equip loads 0 0 Equip. @ 1.00 RSM 21334 liatent cooling 2877 i TOTALS 1647 20312 24211 1000 1000 � I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .'�-� wri htsoftE zo,s-o�c-2s os:ia:os �,- � 9 Right-Suite�Universal 2013 13.0.11 RSU18520 Page 2 � .on\Wrightsoft Files\Express homes\Aria 4EAB.rup Calc=MJ8 House faces: N � — I i _ _ , I . . ' F�RM R405-2014 � RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST ; Florida Department of Business and Professional Regulafion � Simulated Performance Alfernafive (Performance)Mefhod I Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the ' residential Simulated Performance method shall include ❑ Th�s checkl�st � ❑ A Form R405 report that documents that the Proposed Design complies with Section � R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, e-rafio and the pass or fai!status along with summary areas and fypes of components, whefher the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(i page)and an input summary checklist that can be used for field verification (usually 4 pages/may be greater). ❑ Energy Performance Level(EPL) Display Card(one page) ❑ Mandatory Requirements(ihree pages) Required prior to CO for the Performance Method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage" then a completed Form R405 Duct Leakage Test Report(usually one page) I EnergyGaugeC�-USRCZB v5.1 10/ S/2016 8:19:19 AM Page 1 of 1 il i 813-1780-0020 City of Zephyrhills P�rmit Application Fax-813-780-0021 Building Department � Date Receivetl �jQ � ��Tr�_� �l �� Phone Contact for Permitting ;j � ��- l�� i ✓� � p Owner's Namle r� �a a � C Owner Phone Number ���. � �7�v p i , Owner's Address �a6�a�C�e �e �'r' �f �c-�j/Jc.37 3�Owner Phohe Number � Fee Simple T tleholder Name �,rr � Owner Phone Number ! • Fee Simple TI tleholder Address JOB ADDRESS ��o Q�o� ��+`1�� � s°+[ /':.�� �.� L:OT#� �� SUBDIVISIO �1�� 1,G("� �(p PARCELID# dy'���v��� �d�� 'U�� �O-- ���C� • (OBTAINED FROM.P,ROPERTYTAX NOTICE) WORK PROPOSED �NEW CONSTR e ADD/ALT � SIGN Q � DEMOLISH INSTALL REPAIR PROPOSED I SE �� SFR Q COMM � OTHER TYPE OF CO STRUCTION � BLOCK Q FRAME 0 STEEL 0 DESCRIPTIO OF WORK n�� 5����c-�'�n,-� �, I=eS��c�Ct � ���,R�j I2c�-�-� I-�J,o�-� /Gy`).4�+'.�..- BUILDING Sli E S�FOOTAGE ���--/o �/ HEIGHT ` �-r-�-r' i rrrrr�- �� �BU LDING $ `D��� VALUATION OF TOTAL CONSTRUCTION ��� ��� �ELECTRICAL $ ����. Qya AMP SERVICE � PROGRESS ENERGY � W.R.E.C. OPLI MBING $ �m �` � q� ���� � OM CHANICAL $ - /���� �� VALUATION OF MECHANICAL INSTALLATION • �' �'7 OGAIS � ROOFING � SPECIALTY OTHER ��� FINISHED F OOR ELEVATIONS �� � FLOOD ZON ARE �YES NO �y��LG��f SZ�= �d�o ' ��1TT��TT����lTr� ����TO�W ■ • � ITT� BUILDER � � �� COMPANY �� T� , ��.-�d-G� �f'�-C SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N � Addres ����ra�7�C��'CO/� ,/7 r' )M � License# ��C-��`��G� `,.� ELECTRICIA � COMPANY ��✓1 MO��pn ��'�'-C'L�r'� � SIGNATURE �� �� REGISTERED Y/ N FEE CURRE� Y/N Addres + v� �-� 5'Li j��l' ���G�.. c'. License# ��� ��� a g PLUMBER � y� COMPANY (.,��/"/'1 �/'�''y"� /l � �'�ds � SIGNATURE �� `� REGISTERED Y/ N FEE CURRE� Y/N Addres I ��y�p �(,Q �() f � �v� LGL License# v FC }�f;����, � MECHANICA �� COMPANY �r0 r�5v i v� �i r�y s-�m r SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Addres 5��� css�j c/�'f, ���..�-�f L�+r_ License# V �.�� � OTHER ����_ COMPANY I'/ 1 �L Crr'f� �aQ�n SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Addres ��� f d ''f1' .�f' ��:n � License# C� c,.�.�.� ] �r � �'-. 111111; 1111111111111111111111111111111111111111111111111111111111111�, RESIDENTIAL Attach (2) Plot Plans; (2)sets of Building Plans; (1)set of Energy Forms; R-O-W Permit for new construction, � Minimum ten (10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page; (1)set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans vJ/Silt Fence installed, � Sanitary Facilities&1 dumpster.Site Work Permit for-all new projects.All commercial requirements must meet compliance SIGN PERMI7' Attach (2j sets of Engineered Plans. ****PROPERTY SUFIVEY required for all NEW construction. �-:--:�-1..1--1-4.1--1-1-.1--L-1-.1--4-1--1-.i�1-��1--1-�-1-.1--E-1--1..1�1-.1--1-1-.1..1.e1--1-��1..1-1.-1--1.-1-.1--4�1-.1--S-L• • • 1--1--4-1..1.. Directions: I Fill out a plication completely. Owner 8�Contractor sign back of application,notarized � -- ' ' • If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ** Agent(fqr the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing;same OVER THE C�OUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) ' Drivew�ys-Not over Counter if on public roadways..needs ROW _ " ' , , , NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CON"TRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed.in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended, The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issu�nce in accordance with applicable Pasco County ordinances. . CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. _ � CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Waiercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, i Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal;'Aviation Authority-Runways. I understand that,the following restrictions apply to the use of'fill: - Use of fll is not allowed in Flood Zone "V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer � licensecl.by the State of Florida. � - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited:#or violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. � If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for elertrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, canc�;el, alter, or � set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official frorn thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the worl< authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will d,emonstrate - justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR I PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING;CONSULT WITH YOUR LENDER"OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S. 1�17.03) OWNER OR AGENT � �/� CONTRACTOR L�� /J--� _ Subscr' ed and sw9�to.(or affirmed)before me this Subsc'-�sworn to(or affirmed)before me this — � f�by .L C�nn�c"�j��ut!-+c�.L,c L� I by ��r n-n�_�C �c_�sr J-�r_�,•..� . Who is/ar personally known'to me or has/have produced Wh is/a e personally known to me or has/have produced � as identification. as identification. � ` � ' Notary Public � � Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped ��� Notary Public State of Floride a°�Y�eG� Notary Public State of Florida : Gail M Donahue . Gail M Donahue M 9 � My Commission FF 170472 �OF�°�a E pves 11/18l2018 170472 �'oF�°� Expires 11/18/2018 �: i ' � - i " . I I A � � I I ' PLOT PLAN I DESCRIPTION:(AS FURNISHED) j LOT 9, BLOCK 1, SILVERADO RANCH SUBDIVISION PHASE 2, 3 & 4 � AfS RECORDED IN PLAT BOOK 73, PAGE(S) 59-65, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLOiRIDA. .r I P1NE ���RS CAf`R1rV�'IFtPG��,�Nt OF WPV - ��-�2 C4 ��PC 60'W��E PUO�-� i z 0 \N�� 209•68 I o 0 �gEPR �� 1 o a'- � w `R�N1 k,�y 30"�' �:c., ;s�.i � �' +.`{f.�h yr�•y � � - — _ z `� _ 1" - 30' PI � � ''�`" �'- �y"�^'�::�`:� � GRAPHIC SCALE � '; '�`'• �Qo o �L �;s"�t%' _ �>4 � 0 15 30 '�'� � � �'i�:10'��UE�:?.. � �O � _ +..�,^.^,':.'�:i;<- N ��_ � I�G� •;.:..:i:" 'N ,� 1�''r,iit�}'t`'. 1P G�� Q �� p`4 �N� 'u: ;�6y �j�,��;� �� n�� � � h � � � A L � �' � � ,2._��:Y�%;AR\VE°+�� �18.fi ,` c � � �.^•,.. .�... .F,r- �y�� �o y � °'`f `' z,.3 � LOT 10 % ' 3 BLOCK 1 �o\ � Z � 3 0�8;.::•o. � � (/) v�-., I n 19 � o;i �pVEREy c� � � -c Z n.3 ENtt� J z � I (J1� Curve Table CS; � f � U 1 C u rv e � Leng t h Ra dius De l ta C hor d Bear ing C hor d W p560 � W (}1 � PR6 Z 0�'`A '-! � � C1 47.93' 320:00' 834'57' 57836'S8'W 47.89' ���,� Or � ��NI.�p660 I ' C2 247.89' 350.00' 4034'47' N85'23'07'W 242.74' Pi •°'� '� VP� Q C3 52.43' 350.00' 834'57' 57836'S8'W 52.38' � t�� 8 � � I � C4 195.46' 350.00' 31'S9'50' N81'05'3B'W 192.93' ' C����� a� �O� 3B 84 I O) �C:��7 8�-�CK 1 ' -� . � . � Line Table �� 'a �J �Z�'�••a 26•�� ���� Lina d Directton Length �9 �� '�':ils?W.o � �.� � �''-.,�'12.2' �O'� g I � 1oy0 L7 N74'19'30'E 20.53' C '� ~ K w ��� , BR OC�iP/ � o�� - C. � � O / � — — — — 705.9 'm� � 6 ' � . ,30»w 52�a �os.2 �19 � S� � � I � ` 8`OCK 1 , � PREPA ED FOR: \ D•R' ORT[11V"� LEGEND: ,/¢gL'i*i yS�46i{�� - - - BUILDING SETBACK LINE � ON LOT CALCULATIONS - - - CEN7ERLINE BUILDI G SETBACKS LOT = 6,713 SQ. FT ___ _ RIGHT OF WAY LINE FRONT: 22' LIVING AREA = 1,672 SQ. FT. REAR: 13' GARAGE = 432 SQ. FT � PROPosm ELEVATION SIDE: 7.5' ENTRY = 38 SQ. FT. � pROPOSED�DRAINAGE FLOW SIDE STRE T: 22' LANAI = 96 SQ. FT. PAT10 = 0 SQ. FT. 0 CONCRE� DRIVEWAY = 371 SQ. FT. A/C AIR CONDITIONER � A/C PAD = 12 SQ. FT s/W SIDEWnuC NOTE . WALKWAY = 28 SQ. FT PI POINT OF IN7ERSECTION I IMPERVIOUS = 39� PC POINT OF CURVATURE� 1'. ELEV TIONS SHOWN ARE PER LOT GRADING = 2649 SQ. FT. P7 POINT OF TANGENCY PLAN PROVIDED BY THE CLIENT. RP RADIUS POINT 2. ELEV�TIONS ARE BASED ON NAVD 1988 SOD = 4.064 SQ. FT. PRC POINT OF REVERSE CURVATURE OFF LOT CALCULATIONS PCC POINT OF COMPOUND CURVATURE DA I . RIGHT OF WAY = 762 SQ. FT � ��CRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES DRIVE APRON = 133 SQ. FT. ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF PUBLIC S/W = 275 SQ. FT. ��j cn�cuuien SOD = 354 SQ. FT. PB PIAT BOOK THE PROP,OSED HOUSE. REFER TO HOUSE PLAN AND PGS PAGES OPTION LI$T FOR CONSTRUCiION. ALL BUILDING SET BACK TOTALS S4. F7. S4UARE FEET LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT AREA = 7,475 SQ. FT. F.E.M.A. FE�ERAL EMERGENCY MANAGEMENT AGENCY AND IS F�R INFORMATIONAL PURPOSES ONLY. DRIVEWAY = 504 SQ. FT. F.I.R.M. FLooD INSURANCE RATE MAP I SIDEWALK = 303 SQ. FT. NAVD NORTH AMERICAN VERTICAL DANM �HIS IS NOT A SURVEY PLE PRIVAIE LANDSCA E EA EMENTA�M I SOD = 4,418 SQ. FT. ppE PRIVATE DRAINAGE EASEMENT -1 . THIS IS A PLOT PLAN ONLY Pue PUBLJC UTILITY EASEMENT FLOOD NO E: SURVEYOR NOTES: ` I HAVE EXAM NED THE F.I.R.M. COMMUNITY MAP N0. 12101CO228F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE DATED 09-2 -14, AND FOUND THE SUBJECT PROPERTY APPEARS TO LAND SHOWN HEREON FOR EASEMENTS,-RIGHT L1E IN ZONE I , AREA OUTSIDE THE 100 YEAR FLOOD PLAIN. THE OF WAY, RESTRICTIONS OF RECORD WHICH SURVEYOR M KES NO GUARANiEES AS TO iHE ABOVE INFORMATION. MAY AFFECT THE T1TLE OR USE OF THE LAND. PLEASE CONtACT iHE LOCAL F.E.M.A. AGENT FOR VERIflCAT10N. I 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. BEARING BI,p.SIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE�OF 3. NOT VALID WITHOUT THE AUTHENi1C CARRIAGE PI�E COURT BEING N74'19'30'E, PER PLA7. ELECTRONIC SIGNATURE AND THE AUTHENTIC � A M E R I C A N SURVEYORCANDAMAPPER.�ORIDA LICENSED (FIELD DATE:)i REv�sEo: � U R �/E Y I N G :�,� SCALE� ���= 30�T �a;t•�••«o� DigitaltysignedbyJamesWBaleman � � 8cM A P P I N G I N C. ��:�°°""��•�� DN:r—US,st=Florida,l�dando, I APPROVEDBI• �B d� Ameriran5urveying&Mapping, CERTIFlCAiION OF AUTHORIZAl10N NUMBER LBg6393 ����"`01=��s,�aame:weoiema�, 3191 MAGUIRE BOULEVARD, SUITE 200 �'�''•""""�`:`€' ema��=imie�neasmcorPorate<om FOR JOBNO. ��60912 LOT 9, 9LOCK 1 ORLANDO, FLORIDA 32803 �'°�y"�+�.���s� Date2016.702]143]:33-04'00' 7F{E FlRN (407) 426-7979 DRAWNBY: DSB pL07 PLAN 10 26 16 CF �•AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 �A� I r' � � � , � I s I , o +a�• PASGQ COUi�TY Bt1tLDfNG COPISTRUGTtpN SERVlCES . . `_��:'ti ' , j��'ti. p 8731iCitizens Drive Date:4l27120'17 ' � ����� ' Suite 230 "' New Pofi Richey, FL 34654 � ' � ' � �27-847-6'127 i � ; `� ��" ��T � ���I�/��T �� � ; I Record#: 06P�OS-OOQOO�OQ04 ' i ' �� E2eeeint# Paid Bv Check# CC Aath# (Casfiier ID Workstation Receipt Date Amt Paid 1675438 Check 581385 294 BCCCP38W 04127/2017 $42.30 �� I Total Payments: $A2,30 Pa� ar Address I Phane D.�R.HORTON 38060 CARRIAGE PlNE I � Coinments: I P#;�7926 04l26l21lOD?QlOQ1 Q/0090 ! I I ,I ( I i I � � � I � I � � � I MyReport"s reports�lpRODUCTIONlPRSGOlReceiptRA 4l2712017 Page 3 bf 3 � � � �_______,__ (�_______ _ I I _. — ._— —