Loading...
HomeMy WebLinkAbout17-18050 CITY OF ZEPHYRHILLS 5335-8TH STREET ,. - �ei3��so-oo20 18 0 � BUILDING PERMIT SINGLE FAMILY RESIDENTIAL � PERMIT INFORMATION. �� ° LOCATION INFORMATION - " Permit#:18050 Issued: 1/10/2017 Address: 36146 CARRIAGE PINE CT Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: , Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Fe �t: Est. Value: Book: Page: Cost: � 313,868.36 Total Fees: 11,606.19 Subdivision: SILVERADO Amount Paid: 11,606,19 Date Paid: 1/10/2017 Parcel Number: 04-26-21-0070-00100-0160 � CONTRACTOR INFORMATION OWNER INFORMATION - Name: D R HORTON INC Name: DUNE FL LAND I SUB C/O HAWK MANA Addr: 12602 TELECOM DR Address: 2502 N ROCKY POINT DR STE 1050 TAMPA FL 33637 ROCKY POINT FL 33607-5995 Phone Lic: Phone: 813-549-1968 . W rk Desc: CONSTRUCT SINGLE FAMILY HOME 2,951 SQ FT ' � APPLICATION FEES BUILDINC�FEE 1,232.60 ELECTR CAL FEE 254.25 PLUMBING FEE 169.50 MECHANICAL FEE 118.65 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC S� FETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL MPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% ' 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 � �/��( � . �� p�� � ( 4�.��"'" , � � � Ins ections Re uire � ER 2ND ROUGH PLUMB MIS IN ULATION CEILING � FOOTER�OND DUCTS INSULATED SEWER MISC. ROUGH LECTRIC LINTEL MISC MISC. 1ST ROU H PLUMB PRE-METER INSULATION WALL MISC. DUCTS I STALLED WATER MISC DRIVEWAY ' PRE-SLA SHEATHING MISC. MISC. CONSTR CTION POLE FRAME MISC. MISC. REINS�PECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or fir�st reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: � NOTICE: In addition to the'requirements of this permit, there may be additional restrictions applicable to this property that may b'�found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. � "Wa�ning to owner: Your failure to record a notice of commencement may result in your paying twice for` improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." � Comp ete Plans,Specifications and Must Accompany Application.All work shall be pertormed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. � - NO OCCUPANCY BEFORE C.O. ! � � � �, � � � CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER � •- � Gliecic Numbe�• 0569174 l?A Cd'COUNT'Y BOARb OI+COU�ITY Cal17MISSIOtY D�tc 03/30117 � 753 Litfle Road Dl;:�Iizc. Controiled Disb Stub 1 of 1 �91qg� FQ Numb Invoice Hnmber Subdv Loe## Lot Address CosC Cde Legal Desc C3rass Ueductions Acaotsslt Paid -------- --------------- --^^- ---- --•------------______.__._-- -------- ---"--`-- ------------- -----------^� -`---------- 391630a11IF 39163 0011 36146 CARRIAGS PItiE COURT 73/S3 46.38 46.38 --•--'----- -'_-""..-- -`------`-- �a + j� d6.38 A6.38 � t �r � Status:#POS � Appliad:Q4t41/2416 lssued: Typa:_E'ER 1YPE FiRaled: Expired: Category:_pER CAT��ORY 8�b-Type:_PER SUB TYPE � Parce!Number: J�b Address: IlVork Description: I FE�DESGRIPTti�N ACCQ,UNT CODE UNi7S j{�„t}tC� FEE�MOUNT g��ID R�CEtPT# DATE �piicatiort�ee 8104-32200f3 1.00 1237838 $Sfl.00 $SOAO 1683696 316/17 S ate af Flotida pBPRlDCA 8104-2{}8dDS 1.QQ 1237638 �t.00 $4.00 1663686 3/6!'J7 S�rcharge Technology Fee Central B104-342920 1.Q0 123T638 $25.Q0 $25,00 1663696 316117 Permitiing Unticensed ContraotorTaskforce B9Q4-32200i 1.00 1237638 55.00 $5.00 1663686 3/6/i7 S�rcharge TOTALS: $414.00 $114.00 }�ecei # Paid B C ec # CC Aufh# C 1er ld Workstafion Rec�tut Date mt p d 16T'l638 Check 56817� 294 BCCCP38W 04/11/2b17 $�16.38 � Total Paymenfs: �46.38 I �a or Address Phone Gomments: I G�TY fl�F ZHILL.S SW PAYMEtV'f FOR PERMIT#18050 � � ; MyReportslreports!/PRODUCi"ION/PASCOIReceiptAA A/i'fl2Q1? p��� ,�f� � - — , , � i�Y1►►e7�i� �e��d���q ���JI'�l6J� i' i " ' Petmit No, ! ��lJ"�� Date Permitted . - �_ Bui{der NametOwner Name � � �"�� L�G Control# County Parcel No, ��-Z�-Z�-DD�f1�G�DIQa�-aJ�a SubDiv; c5! i/U��a Address(Location �y�p j��y �t,i�r`P�2 J't�2. C� Ciassificafion(type of Use v`^r�''���� yzLm�l� l�'e-� ' TRANSPORTATION iMPACT FEE Rate: Sq Ft Unit: �'/��� , Exempt [� Yes [] No Haw Determined tmpact Fee Amount $ 3�3Z' Zane No. TAZ: SCHOOL IMPAC7 FEE Account (056) Singls-Famity Detached House Rmount $ �f �]�� Z�a (057} Mobife Home (058) Other Residential 123) ColEection Fee Exempt [S] Yes (� No How Determined PARKS Al�Q RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credik Recreation Total Zone T07AL AMQUNT $ ����v�� Exempt �]Yes (� Na Haw Datermined LIBRARY FEE Land Accaunt Land Credit Land Tatal Facifity Accaunt Facility Credit Faciliry Totai Exempt � Yes � No Haw Defermined Total Atnount � RESQURGE FEE EF2U TOTAL AMOUNT Prepared By ' Checked By NC?CERTIFiCATE OP dCCUPANCY WILL BE ISSUED OR FINAI.INSPECTION PERFO}2MED UNTIL THE TOTAL AMOUNTS LlSTED HAVE BEEN PAID AND RECEtPTED FOFt BY A CE4dTRAL PERMITTING OFFiCE O�PASCO COUNTY Acknowledgemenk below does not!mp{y acceptance of concurrencs,but simpiy recalpt of a wpy of khis form,placing the bufiding perrnit owner on notice of this assessmenk and ttta conditions af payment for same. DATE RECENED SY RECElP7 NO. DATE 8Y � . . .. ' ,.�.�.��,.�..-._�,��.��..-m._... ._.________- ____ �..� _.�._�_�:_:.�._���. a _ d 0 -26-21-0070-00100-0160 � Pasco County Property Appraiser Page 1 of 1 , • Data Current as Of: Weekly Archive - Saturday, December 31, 2016 ParcelID 04-26-21-0070-00100-0160 (Card: 001 of001) Classification 00 -Vacant Residential � Mailing Address Property Value DUNE FL LAND I SUB LLC Ag Land $0 C/O HAWK MANAGEMENT CO LLC Land $901 2502 N ROCKY POINT DR STE 1050 � ROCKY POINT FL 33607-5995 Building $0 Physical Address Extra Features $0 36146 CARRIAGE PINE CT ZEPHYRHILLS, FL 33541 7ust Value $901 Legal Descriution (First 4 Lines) Assessed (Non-School Amendment 1) $901 SILVERADO RANCH SUBDIVISION PHASES 2, 3 &4 PB 73 PG 059 BLOCK 1 �oT 16 Taxable Value $901 � 7urisdiction Citv of Zephvrhills I Land Detail Card: 001 of 001) __ _� Line---1- Use jDescription Zoning �Units Type Price Condition Value ' 1 0100 ( SFR� MPUD �11,264.00 �SF � $0.08 � 1.00 i $901 Additional Land Information Acres� 0.26-�.�sj-vTax Area� 30SI f FEMA I __ �Residential Code NEWSUBB � ! � � Code � � Building Information -Use 00 - Unimproved (Card: 001 of 001) Unim roved Parcel 00 - Unim roved i Extra Features(Card: 001 of 001) , Line ���� Description Year ��' Units _�i--�� Value ` -___ . � _�.___.._1__� �.__._______ _._. No Extra Features Sales Historv-See All 5 sales Previous Owner: ' _ Month/Year Book/Page_ ��__� �Type � DOR Code Condition � Amount � 09/2011 8606 / 3376 �� Warranty Deed � 05 ( Vacant � Multi-Parcel Sale � i 05/2010 8373 / 1912 Certificate of Title 12� Vacant ! ��$0 I -- - -- --- --- �— ^ ---;---- . 07/2005 6725 / 1059 Quit Claim Deed � Vacant � $0 � � � , � � . h ://appraiser.pascogov.com/search/parcel.aspx?parce1=2126040070001000160 1/4/2017 iiiiiiiiiiiiiiiiiiiiiiiiiiiii�iiiiiiiiiiiiiiiiiiiii�iiiiiiii � 2017003881 ' Repf.:1828861 Ree: 10,00 DS: 0.00 IT: 0.00 01/10/2017 K. D. K., Dpty Clerk Permit N0. Parcel ID No,��('�C! ���(d��� ���e r� / NOTICE OF COMMENCEMENT/"� Sla�e of �l d I I��� County of Y QJ� THE UNDERSIGNED hereby gives nolice lhal ImprovemeM will be made to certain real property,and in accordance wllh Chapter 713,Florida Slalutes, the follo�ng information is provided in lhis Notice of Commencemenl: � ,C� 1 Descriptlon of Property Parcel IdenliFlcation No. 1 1 Sireel Address: (' �/ ' 2. General Descriptlon of Improvement }�Ln� J l/�Q �� t' V1/1�� I� ��i(i 1��.� 3. Owner Information or Lessee information If lhe Lessee contracted for the Improvemenl: � "� � l'�o n �n - 1��a O z. N�P��PIC]M �r �Q. �na�I G� ����3� S��L Address r City Interest in Property: T e� ��N�fO��. --— Name of Fee Simple Tilleholder (If dif(erent(rom Owner Iisted above) Address '[� � I I ��,, City Slafe 4. Contractor��I1 pf�'[Z/�� � 7/ -7 W `-L �.0�nnl ame��.1��11'� �r �l��Q �JC9i� 7' �L Cn W LL. � I1J w Atltlress City Slale � � � � = J U Contraclor's Telephone No.. � z U O �— � � 5. Surety: ��Y-h � Na—m— � � � F— l� Nd o Address � City Slale O O = z J � Amounl of Bond: $ f`L/� Telephone No.. �' I� ~ � Q 6. Lender: ,� � _ � � �y, � Name � � aWO Y Address Cily Slate � _ � V Oc W � Lender's Telephone No. � I— � J —� 7 Persons wilhin Ihe Stale of Florida designated by lhe owner upon whom notices or olher documenls may be eerved as provided by � � w m � � V Section 713.13(1)(a)(7),Flor(da Statules: O � � � Q O J �, QII��C� �`;+(7�-2, -� W O Q = o Z Name /'�( —}� /'-� O ��N-�t�t-o�D�s� �! I��� c �LP. )T State �" t� 0 Q � /,,�7 � �- Z � cn Te ephone Number of Designaled Person: �� ' ��7(/"���� w � Q J w 9/�/�_ 0— � w LL.. Z B. In addition lo hlmseif,lhe owner designates �///-T � of_ � _ � z F-, Q } lo receive e copy of Ihe Llenor's Nollce as provided In Sectlon 713.13(1)(b),Ftorida Statutes. � �"- F' � � a m Telephone Number of Person or Enti�y Designated by Owner 9. Expiratlon dale o(Nolice of Commencement(the expiration date may nol be before lhe complelion of construclion and final payment to lhe �„`�'Q �° � 8d contractor,but will be one year from the date of recortling unless a different date is specified): �0�. e � 'v • � WARNING TO OViINER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1. SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERN A NOTICE OF COMMENCEMENT MUST BE O y r � � RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATfORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT � ' � ��;a�,) � Under penalty ofperjury,I declare that I have read ihe foregoing nolice of commencemenl and lhat the facts staled lherein are lrue to lhe besl � ' �� �1� 'm� of my knowledge and belief. .� o �r � STATE OF FLORIDA � , .� ,� �`� � � � COUNTY OF PASCO � Sign ture of Owner or Lessee,or Owner's or Lessee's Authorized � e�,�� Office irectodPaMer/Manager �� Q •��s flssf � �l'Q-���� - ]7�� Nn�r�t��r� � � Signatory's T(tle/Oifice �"' The foregoing Inslrumenl was acknowiedged before me lhis�,day o(�20[(�by 1�l ✓�� � �� as � � � � (lype of aujtior' , .g.,oKcer,trustee,atlorney in facq for ' � 1 •�O� (1 /1� ( ame of on � of w m instrument vras executed). � Perso}�ally Known�OR Produced Idenlitication❑ Nolary Signatur Type Of Idenlificalion Produced Name(Print) �'j'•� IFFA LYNN BAflAB �;.� ;��: MY COMMISSION 9 FF 154528 PRULq 5 0'NEIL,Ph D PqSCO CLERK B COMPTROLLER 'S�' !F E%PIRES:S9plBlllb6f28,2018 01/10/201Z 0�;e�m 1 f '?qe„h••' ecneeenwNoteryvuerou�w�rten OR BK 948 P� �0�►g wpda a/bcs/nolicecommencemen1�c053048 � _ 36146 Carriage Path , ' o umn . � SQ. FEET PRICE , UNDER ROOF: 2,951 $ 106.36 OTHER: - $ - ' VALUATION $ 313,868.36 � FEE SHEET $ 1,130.00 ; ADDRESS $ 40.00 ' DRIVEWAY $ 40.00 , BUILDING: $ 1,232.60 ELECTRICAL: $ 254.25 PLUMBING: $ 169.50 MECHANICAL: $ 118.65 , SUB-TOTAL $ 1,775.00 TOTAL $ 1,775.00 � SEWER: WATER: IRRIGATION: $ - ' TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL , � TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 � FIRE $ 273.00 , 5% $ 26.35 TOTAL: $ 553.35 � SUB-TOTAL $ 2,328.35 ! , PARK IMPACT FEES $ 769.56 � � � SIF'S: $ 4,828.00 ' ! 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 I 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,606.19 _ � , - — � 813-780-0020 City of Zephyrhills Permit Applicatian F�x-813-780-0021 BuildingDepartment �s j�����i���������` ��� l� D'ate Received ' �_ I Phone Contact for Permittin -- Owner's N�� � a e^, � � Owner Phone Number ��(��, �. ��� Owner's Arldress ���'da���'° '�-� �""" �✓' ��-+'r•�✓J�33 3�qWner Phohe Number �� � Fee Simpl' Titleholder Name �,;,}'G,,rw � � Owner Phone Number �� � � i Fee Simpl Titleholder Address �'�`f- �oa aaoRi�ss v1�1 y� ��'-r� �.�-r �i _ � ��� �� �tC' LOT# `�_' SUHDIVtSJQ N ��1 ( 1-a'G("'� c�ca PARCEL ID# �f��f'r�/ I (OBTAINED FROM PflOPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADQ/ALT 0 SIGN Q � dEMOLISH I �INSTAL.L e REPAIR � PROPOSED USE � SFR Q GOM�If � OTHER � TYPE OF C�QNSTRUCTION � BLOCK Q FRAME 0 STEEL 0 � DESCRIPT�ON OF WORK ��� ��°�jr1�7�n-�-�� I'�'T�c���"� �rt�� bex-'�-� -f;�o� BU1LDtNG S1ZE � Sa FOOTAGE Br 7�i� HEIGHT M �������N� � ,l�S, ��'f� VALUATION OF T(7TAL CONSTRUCTION OE EGTRICAL $, ��� �� AMP SERVICE O PROGfiiESS ENERGY 0 W.R.E.C. QP UNiBiN� $ �, � Q�� � � ���'a �MECHANICAL $ /'��� � VA�UATIOIV dF MEGF{ANIGA�INSTAI.EATI4N �lr�' �Gf�S ��FtQOF1NG Q SPECIALT'f � OTFiEA � FINISHED LOOR ELEVATIONS /��/ �� FLOOD ZONE AREA �YES NO 7� -1-1- t-1�-1-1-�1•�4-1-1-1-�--1-•1-1--1�-1-1-�t-4-1-F-�--1-ift-b-1-1-1-�-1-1-1-1-i-1-t-4-6-• • • • • • • • • • • • 1-1��-1- SIGNATURE � r���-�'y '�� �OMPANY �4� - �'I��"'�^+ �J`4 e REGISTERED Y/ N FEE CURRE� Y/N Addre s l���r���C �CCo f+'I /��"' �� '"� License# ��C.C���Ca G� � � ELECTRICi�t�t � GdMPANY ��Y J`�Cir��p� ��'�'�-=��' � � SIGNATURE �"" �""��~� � REOISTERED Y/ N FEE CURRE� Y/N I Addre s i �l" �G ��- I �� �` �� i� ,�1c� rr' License# �����':► � C3� � � ...s—�" P�UMBER � ,,,,�� CQMPANY t.,.�d/""�'1 Lv!"-�'7� �!'e--/ O""`a�� �IGNATURE REGISTERED Y/ N FEE CURRE� Y/N Addre�s � �,�rp �.(,Q �� License# �� � �7 %�«�- � ,, �- /��,t L�L Fc u MECHANIC�L ��.�_�,� COMPANY �I"L� (`�,'"S} 1 t��. CK�!"'St� $'��.� f' , SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Addre�s 5�j f�� E,rj"h�/��f, �G�-r��cr��e License# VJ``T��J3 4�1(�� � QTHER I ������--,�,,,_ COMPANY � 1 b�f'r/''r:� �UQ�n SIGNATUR� REGISTERED Y/ N FEE CURRE� Y/N i Addres ��� � �`'-�'�' .�'l� �e�:n +�" License# �� �'..�� � {r� � � ' 11111 11111111111111111111111111111l / 11111111lIlliliili ! ! ! ! lillttll RESIAENTIA� Attach(2)Plot P(ans;(2)sets of Buitding Alans,{i)set of Energy Farrns;R-O-W Permit for new construction, Minimum ten (1 Q)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, 8anitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCt�L Attach{2}complete sets of Bui(ding Pians plus a Life Safety Page;(i)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Fiequired onsite,Construction Plans,Stormwater Plans w/Silt Fence instalied, � Sanitary Facllitles&1 dumpster.Site Wark Permit for a11 new projscts.AIt commercial requirements must meet compiiance SiGN PERM�T Attacfi{2j sets of Engineered Plans. ' **'t*PROPERTY SURVEY required for all NEW construction. , � ._,,,,�,,,�;,�;,.t�l--i�■ . . . . . . .. . ��■ . . . , . . . . f.-i...i..i-i--L-l-i�...l-I..i-�i�I-l..i-i-1--i..i-i--i..�..` ',--.:�:.�.�.p.��{-i-�i..i-. Directions: � _ , Fill out applicatlon completely � • Owner&Gontraotor sign back af appticatian,•notarized If over$2500,a Notice of Commencement is required. (,A/C upgrades over$7500) ** Ageht(f�r the contractor}or Ppwer of Attorney{for the owner)would be someone with notarized letter from owner authorrzfig same OVER THE COUNTER PERMITTING (copy of contract required) Reroafs if shij�gles Sewers Service Upgrades AJC_, Fences{PlotJSurvey/Footage) privewiys-No#over Counter if on public roaiiways:.needs:RO.W � � ,. i I , . ; , 4 � NOT(CE OF D�ED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions"' which may be more restrictive than County regulations. The undersigned assumes respansibi(ity for campfiance with any ` � applfcable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or cantractors ta undertake vuark, they may be required ta be licensed_in accordance wi#h state and local regulations. If the cantractor is not licensed as required by law, both the owner and contractar may be cited far a misdemeanor violation under state law. if the awner or intended cantractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection bivision—Licensing Sectian at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractar(s) sign portions.of the "contractor Black" of this application #or which they wi(I be responsible. If you, as the owner sign as the contractar, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco Caunty. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transpartation Impact �ees and Recourse Recovery F'ees may apply to the cons#ruction of new buildings, change of use in existing buiidings, or expansion af existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended, The undersigned also understands, that such fees, as may be due, will be identified at the time af permitting. It is further understood that Transportation Impact Fees and Resource Recavery Fees must be paid priar to receiving a "certificate of accupancy" or final power release. If the praject does not invalve a certificate of occupancy or fina! pawer release, the fees must be paid prior ta permit issuance. Furthermore, if Pasca Cottnty Water/Sewer lm�act fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Sta#utes, as amended): !f valuation of wark is $2,50Q.00 or more, I certify that 1, the applicant, have been provided with a capy of the "Florida Canstruction Lien Law--Nomeowner's , Protectian Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someane other than the"owner", 1 certify that 1 have obtained a copy of the above described document and promise in goad faith to deliver it to the"owner" prior to commencement. CONTRACTOR'SlOWNER'S AEFtDAV1T: I certify that all the infarmation in this app(icatian is accurate and that al!wark will be done in compliance with all applicabie laws regulating construction, zoning and land deveiopment. Application is hereby made to obtain a permit to do work�and installation as indicated. I certify that no work or installation has � commenced priar to issuance of a permit and that all work wili be performed to.meet standards of all laws regu[ating construction, County and City cades, zoning regulations, and land develapment regulations in the jurisdiction. I also certify that I understand that the regulatians af other gavernment ageneies may apply to the in#ended work, and that it is my responsibi�ity to identify what actions ( must take to be in compliance. Such agencies include but are nat limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,WaterMlastewater Treatment. • - Sauthwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercaurses. � � � - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department af Health & Rehabilitative SenriceslEnvironmental Health Unit Wel4s, Wastewater Treatment, Septic Tanks. , - US Environmental Protectian Agency-Asbestas abatement. - Federal Aviation Autharity-Ftunways: I understand that the following restrictians apply to the use of fill: - Use of ftl! is nat allowed in Flaod Zone"V" unless expressly permitted. - If the fi(1 material is to be used in �lood.Zone "A", it is understoad that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licenseci by the State of Florida. � - If the fill material is to be used in Fload Zane "A" in connection with a permitted building using stem wall canstruction, 1 certify that fifl will be used anly to fill the area within the stem wafl. - If fill material is to be used in any area, I certify that use of such fiill will not adversely affect adjacent properties. If use of fill is found ta adversely affect adjacent prapertiea, the owner may be cited for violating the conditians o#the building permit issued under the attached permit applica#ion, for lats less than one (1} acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FdR THE 01lttNER, 1 promise in good faith to inform the owner of the permitting canciitions set forth in this affidavit prior to commencing constructian. I understand that a separate permit may be required for electrical wark, pfumbing, signs, vuefls, pools, air conditioning, gas, or other installations not specifically included in the applicatian. A permit issued shali pe construed to be a license to proceed with the work and not as authority to violate, cancel, aiter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction af errors in plans, canstruction ar vialatians af any codes. Every permit issued shall become invalfd unless the worl< authorized by such permit is commenced within six months of permit issuance, or if work autharized by the permit is suspended or abandoned for a period of six (6) months after the time the work is cammenced. An extension may be requested, in writing, fram the Building Official far a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If wark ceases for ninety (90} consecutive days,the jab is considered abandoned. WARNING TO OWNER: YOUR FAIL,URE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FC}R [MPROVEMENTS TC}YOUR PRCIPERTY. IF YOU INTEND TO QBTAIN F1NAI+iC1NG,CONSULT WITH YOUR LENDER OR AN A7TORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMEIVT. FLQRlDA JURAT(F.S.117.-Q3) OWNER OR AGENT� ��'""-��—' CONTRACTOR � �� w Sub cribed and sw4�to{or affirme�d}b�_efore me this 8ub r d swomt^ta�(or affirmed)before me this �ti'p�����'1��, by .V�'+�'.–tt n-t'Lz�_.eZ est..�^�e�.�«e � � by V�s r►n r �iL ��.a�r l-�.��-.... . ,_� o is e personally I<nown to me or has/have produced h is/ar personally known to me or has/have produced as identificatian. as identificatian. , �~ x1G� Natary Pub[3c `�• ��±����"��---- Notary Public _{���_�����--""� ���i�� Commission No. Commission No. Narne of Not�ary�ty�ped,printed or stamped Name f t , r'�c ,�t�p �Y°�e Nota Public State of Florida �Y°�'e� Notary Pubtic 5tate of Ftarida � � �` �°� ° Gail M Donahue ;� ; Gail M Donahue � 4� �y Commissian FF 170472 � �� Niy Commissian FF 170472 �'�oF�� Expires 1 tt18J2018 oFp. Expires 11/18/2018 PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 16, BLOCK 1, SILVERADO RANCH SUBDIVISION PHASE 2, 3 & 4 S RECORDED IN PLAT BOOK 73, PAGE(S) 59-65, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. Curve Table pC Curve � Length Radius Deita Chord Bearing Chord �Rf�j�e C7 42.60' 55.00' 44'22'S2' N81'S7'54'E 41.55' � 564�8 3 fFqR�Hc) — — LEGEND: �f � — BUILDING SETHACK LINE R��yt�Rv\ - CENiERLINE O�F pf. �g3 qRR� WqY 36• — - - RIGHT OF WAY L1NE P,4i�q� qcF p� \ � PROPOSED ELEVA710N R��'`/T �qCT�F \\ � PROPOSED DRAINAGE FlOW ��lYqY� �Q/, � CONCRETE V � ��D�, R� jO/ p�C AIR CONDITIONER � �qRiFS� � � S/W SIDEWAtx PI POINT OF INTERSEC110N z p, PC POINT OF CURVATURE � � PT POINT OF TANGENCY 1" = 30� y�y RP RADIUs POINT GRAPHIC SCALE =N ry PRC POINT OF REVERSE CURVATURE / PCC POINT OF COMPOUND CURVANRE 0 15 30 Rq� TYP TYPICAL v� CS CONCRElE SLAB I (P) PER PLAT / (�� CALCULATED o/ PB PLAT BOOK PGS PAGES �y� SQ. Ff. SQUARE FEET F.E.M.A. FEDERAL EMER�ENCY MANAGEMENT AGENCY � � ON LOT CALCULATIONS � F.I.R.M. FLOOD INSURANCE RATE MAP LOT = 11,265 SQ. FT. , . - NAVD NORTH AMERICAN VERTICAL DANM _ 4i NGVD NATIONAL GEODE7IC VERTICAL DATUM - 1019 S . FT. LIVING AREA , Q o/ D&UE ORAINAGE&UTILITY EASEMENT GARAGE = 432 SQ. FT. ,NI PDE PRIVATE DRAINAGE EASEMENT ENTRY = 87 S4. FT. \ Q� PUE PUBIJC U7ILJTY EASEMENT LANAI = 0 SQ. FT. / PAT10 = BO SQ. FT. 2� • DRIVEWpY = 242 SQ. FT. \� �F�Ni,y� l .:,.., �� A/C PAD = 12 SQ. FT. \��eqT Hp �,�-,�-,-�,-�x,�,. MPER �US = 7% SQ. FT. �i��l �,...3::_.=:.::=;.. ,_,�;i,,•_' 9see �� z,;..:."..'. r, +�;1.ih-''. 1909 SQ. FT. l '>��'r>i:':;:;�::`.;:•.�;'.`:``"" I 1a :'��s,.;�::;t'^.r,;, SOD = 9,356 SQ. FT. �o�' l;.�nto' uE:s,' OFF LO CALCULATIONS :�:r, y�.� � T / / ✓r:�:'-:r:c::a=; RIGHT OF WAY = 301 SQ. FT. / � �;�rrg;..rR-: o DRIVE APRON = 5 SQ. FT. I � N ;`;';Y,,ts,o':.�,' '-� PUBLIC S/W = 203 SQ. FT � '':'�.''bF21VE.y:i.,...., i'� �(� � I :i::C�' r SOD = 93 SQ. FT. � 10.8' - . b;r`i':Y .,>,, �6 �� ya � < TOTAL9 � � � 21.3' .<<o:,._, �\ ��9J < �� i AREA = 11,566 SQ. FT �;,��;:��?y5�;:•;, - � O DRIVE PY = 247 SQ. FT I � / �:?> ^ I � / � COVERED .��17.3•:c•; � �'+ � �� SIDEWALK = 240 SQ. FT � � � � p ��Y � "� SOD = 9,449 SQ. FT. � � � lQ � � O O I � /''' PROPOSED \ � J m � �' a % � 4EG8 GAI.EN ri \ � o � g FlNISH FLOOR � � � � ELEVA710N=104.20' I ! 38.84' �h$ � J / ��% 38.7' PATIO � �� � 3 � =�•;� � •� � �o i -� �- i s.N i i �°� i \ 0 i � i \� / PREP'4RED FOR: �� ti��' %� N L � j — 11�H-N(11�TtiN'�,� � � � �T 16 / Frsc�#-1ca=,-,�'uc'<a'_ n°ti° ��— — — _ BLOCK � � ,o,, � � — _ _ �i.zss SQ � / BUIL �ING SETBACKS� _ 1 � — _R'vNAGE TypE q / ,y> FRONT: 20' � � � � � � REAR: . 15' �pa•`' (L , ,_ SIDE.STREET: 20' N80•07�12„w D��''�� QP �0 0�' � NOT�S: p 113.11' �� � c,� 1. E�VATIONS SHOWN ARE PER LOT GRADING PR'A"ACT "A" ,oa5 �� �.y,� P NS PROVIDED BY THE CLIENT. TE DRqINq�E qR 2. ELEVATIONS ARE BASED ON NAVD 1988 � � � O � DAifUM. / P 0�/ 4P G ,�, THIS PLbT PLAN IS INTENDED FOR PERMITTING PURPOSES � '�� � 00°� ONLY. 7�IS IS NOT INTENDED FOR THE CONSTRUCTION OF THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND u�$�' OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK � � Q LINES SFiOWN HEREON IS PER DATA FURNISHED BY CLIENT � �Q� AND IS �FOR INFORMATIONAL PURPOSES ONLY � THIS IS NOT A SURVEY � � �fHIS IS A PLOT PLAN ONLY / � ' FLOOD NOTE: SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M. COMMUNITY MAP N0. 12101CO228F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE DATED 09126-14, AND FOUND THE SUBJECT PROPERTY APPEARS TO LAND SHOWN HEREON FOR EASEMENTS, RIGHT LIE IN ZONE X, AREA OUTSIDE THE 100 YEAR FLOOD PLAIN. THE OF WAY, RESTRICTIONS OF RECORD WHICH SURVEYOR�MAKES NO GUARANTEES AS TO hiE ABOVE INFORMATION. MAY AFFECT THE TITLE OR USE OF THE LAND. �' PLEASE CiNTACT THE LOCAL F.E.M.A. AGENT FOR VERIFlCATION. � 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCAiED EXCEPT AS SHOWN. BEARING�BASIS: BEARINGS�SHOWN HEREON ARE BASED ON hIE CENTERLINE OF 3. NOT VALID WITHOUT THE SIGNATURE AND II CARRIAGE�FINE COURT BEING S64'28't3'E, PER PLAT. THE ORIGINAL RAISED SEAL OF A FLORIDA � A M E R I C A N �CENSED SURVEYOR AND MAPPER. (FIELD DA :) REVISED: S�A�E: �' = 30 FEET � U R �/E Y I N G APPROVEq BV• �B 8cM A P P I N G I N C. CERTIFlCAiION OF AUhIORIZA710N NUMBER LB//6393 160912 LOT 76, BLOCK 1 3191 MAGUIRE BOULEVARD, SUITE 200 FOR Jos No. ORLANDO, FLORIDA 32803 Ru (407� 426-7979 DATE oruwNev DSB pLOT PLAN 11 12 16 CF �WAMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 c Y � FOf�'M R405-2014 Fl�fJRIDA ENERGY EFFIGIENCY CODE Ft3R BUILDING CONSTRUCTiON; �� Florida Department af Business and Professiana! Regulation - Residential Performance Method � Project Name: Galen Elevatian py�� Builder Name: � xpre F3ame / , i Stre t: ,,,�� N� �(rj � "�I�n2la Permit Office: �������i� ''/��S' Gity,�State,2ip: Zephyrhi!!s,FL,��G� , 1 Permii Number: r dwner: ��� Jurisdicfiorr. �j�j�� Design Location: FL,Tampa j/_ County:: Pasco(Florida Climate Zone 2) r �Q 1. Ne 1 construction or existing New(From Plans) 9. Wall Types(2511.6 sqft.) Insulation Area 2. Sin�fe family or muliiple family Single,family a.Frame-Wood,E�erior R=11.0 1269.3�ft2 b.Concrete Block-Int Insu1,Exterior R=4.i 958.22 ft2 3. Nur�ber of units,if multiple family 1 c.Frame-Wood,Adjacent Ft-11.0 286.d0 ftz 4. Nu �ber of Bedroams 4 d.N!A R_ ftz 10.Ceiling Types (145i.0 sqft.) - Insulation Area 5. Is t is a worst case? No a.Under Attic(Vented) R=30.0 1451.00 ftz 6. Gon�ditioned floor area above grade{ft2) 2432 b.NIA F?= ftz Con�ditioned floor area below grade(ftz) q c.NIA R= ftz 11.Ducts R ftz 7. Win�ows(229.0 sqft.} Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd F3oar B 231 a. l�-Factor: Dbl,U=0.34 189.00 ft2 b. �HGC: SHGC=0.31 � -Factor. Dbl,U=6.55 40.00 ft2 12.Gaoling sysiems k8tvihr E�ciency �HGC: SHGC=0.34 a.Central Unit 33.8 SEER:14.00 c. lS!-Factor: NiA n2 aHGC: 13.Heating systems k8tu/hr Efficiency d. l.�-Factor: N/A ftz a.Electric Meat Pump 33.8 HSPF:8.20 I S�GG; � Are i Weighted Average Overhang Depth: 1.585 ft. I Are�Weighted Average SHGC: Q.315 14.Hot water systems 8. Floo Types (1451.0 sqft.} (nsulation Area a.Electric Gap:5d gailons EF:0.950 a.SI -On-Grade Edge Insulation R=0.0 1 Q19.00 ft2 b. Conservation features 6.F3 or aver Garage Fi=19.Q 432.00 ft2 None a c.N A R= ftz 15.Credits Pstat I Glass Floor Area: 0.094 Total Proposed Modifiied Loads: 74.30 � A CrL+ Total Baseline Loads: 74.48 f�i`��� i here y certify that the plans and specifications cavered by Review of ihe plans and • �"���2'.q�, ' this c cu(ation are in campiiance with the Florida Energy specifications cavered by this �� _�,��0 Code.i calculation indicates compliance � �,,,'4` _'_�,.o ��s• with the FEarida Ener Code. F•� r�r,r�..`r,., .,-.-.�.`�,�`" t^ 9Y '� � �.",`�.. t7 PREP RED BY: ��► Before construction is completed w� { 5' ,'', . � DATE ��-`�-�6 this building will be inspected far � "`�°;�"` - ,� compliance with Section 553.908 * �'' II * I hereti certify that this building, as designed,is in compliance Florida Statutes. �+,�.� - �� with th Flor9da Energy Code. � ��U y�`�`� OWN� R/AGEN . BUILDING OFFICIAL: ; DATE� DATE: � , - Gam liance requires certification by the air handler ttnit manufacturer that the air handler e closure quatifies as � certi ied factory-seated in.accordance with R403.2.2.1. -Com liance requires an Air Barrler and Insulation Inspectian Checklist in accordance with R402.4.1.1 and an envelope leakage ' test re` ort in accardance with R402.4.'t.2. 1 1/4/201 6 4:10 PM EnergyGaugeCN USA-FlaRes2014 Sectlon R405.4 1 Compliant Software Page 1 of 5 , I , � ` � - i F _ . FC1E�M R405-2014 F QRIDA ENERGY EFFIC�ENCY CODE �OR BUIi.DING CONSTiRUCTIOi�� lorida Department of Business and Professional Regulation - Residential Performance Method ' Project Name: Galen Elevation Buiide�tlame: DRH F�cpress Flomes Stre�t: ,�' �� �('�'j e„�j'j1Q,�,,'� Permit Office: City,�State,Zip: Zephyrhills, FL,��G� . J Permit Number: Qwner: �L� dudsdiction: Desi�n Location: FL,Tampa %/ County:: Pasca(Florida Climate Zone 2) ! 4Q 1. Ne�construction or existing New(From Plans} 9. Wall Types(2511.6 sqft.} Insulation Area 2. Single family or rnultiple family Single-family a. Frame-Wood,Exterior R-11.0 1269.30 ftz b.Concrete Black-!nt 3nsul,Exferior R=4.1_ 95fi.22 ft2 3. Nu(ber of units,if muitip(e famiiy 1 c.Frame-Wood,Adjacent R�11.0 286.00 ftz � 4. Nu ber of Bedrooms 4 d.N/A R� ftz 10.Geiling Types {145f A sqft.} Insniation Ar�a 5. Is t is a worst case? �o a.Under Attic(Vented) Ft-30.0 1451.00 ftz 6. Co ditioned floor area above grade.{ft2j 2432 b.N!A R= ftz Co�ditioned floor area below grade(ft� 0 �'��A Fi- {�z 11. Ducts R ftz 7. Win�!�dows(229.0 sqft.) Qescriptian Area a.Sup:Attic,Ret:2nd Floar,AH:2nd Fioor 6 231 a. u-Factor. DbI,Li=6.34 189.00 ftz HGC: SHGC=0.31 b. -Facior. Dbl,U=D.55 4p.pp{�z 12.Caoling systems kBtuihr Efficiency HGC: SHGC=0.34 a.Central Unit 33.8 SEER:14.00 c. �Factor; N!A ftz HG�� i3.Heafing systems kBtu/hr Efficiencry d. -Factor: N/A ftz a.Electric Heat Pump 33.8 HSPF:8.20 HGC: Are Weighted Average Overfiang depth: i.585 ft. Are'Weighted Average SHGC: 0.315 14.Hnt water systems a.Electric Gap:5Q gatlons 8. Floa Types (145i.0 sqft.} Insulation Area EF:0.950 a.SI b-On-Grade Edge Insulation R=0.0 1019.00 ftz b. Conservation features b.Fl�ior over Garage A=t9.Q �t32.04 ftz None c.N/� R= �2 15.Credits Pstat Tatal Proposed Modified �oads: 74.30 PASS Giass Fioor Area: 0.094 Total Base(ine Laads: 74.48 I hereb certify that the plans and specifications cavered by Review of the plans and ���ST,q�,� this ca cuiation are in cornpiiance with the Florida Energy specifications cavered by this �,� = � p Code. I calculatian indicates compliance ��.�'�,��''µ ;���,ra � with the Florida Energy Code. � r�rrr� '�r=,��;.�`��, � PREP' REL� BY: ___��5�� 8efore constructian is compieted r`� ':� QATE II-4-IG this building wi0 be inspected far � ' � � , compiiance with Section 553.908 * '' � * I hereb certify that this building, as designed, is in compliance Florida Statutes. ,,,� _ �,S with th�FlQrida Energy Code. �Q�,��� OWN�R/AGEN . BUILDINC OFFICIAL.: DATE�' DATE: - Com liance requires certification by the air handler unit manufacturer that the air handler enclesure qualifies as • certff ed faciary-sealed in.accardance with R403.2.2.1. � , -Com tiance requires an Air Barrier and Insulation Inspection Checklist in accordance with R4Q2.4.1.1 and an envelope leakage ' test re�ort in accordance with R402.4.1.2. , 11/4l2016 4:10 PM EnergyGaugeB USA-FlaRes2014 SecYion R405.4 1 Compliant Software Page 1 of 5 . _ i� . s���� �'��rJ—'���� �� PROJECT Title� Galen Elevation D Bedrooms: 4 Address Type: Lot Information , Buii�ing Type: User Conditioned Area: 2432 �.ot# �81t Own�r. Total Stories: 2 Block/SubDivision: Silverado Ranch 'I #of Units: 1 � Worst Case: No PlatBook: �. 8u�1 er Name: DRH Express Homes Rotate Angle: d Street: j Pe it Office: Cross Ventilation: Caunty: Pasco � Juris�liciion: WhoEe House Fan: Ciry,State,Zip: Zephyrhi!!s, Family Type: Singie-fami(y FL, . New�Existing: New(From Plans) Gom�ent: �arage R Face N - � GLtMATE , / IECC Design Temp Int Design Temp Heating Design Daily Temp V i design�acatian TMY Site Zane 97.5'l0 2.5°lo Winter Summer Degree Days tvfoisture Range � FL,Tarnpa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Nu�nber Name Area VoEume 1 Blockl 2+332 20i38.7 SPACES Nujnber Name Area Volume Kitchen Occupants Bedroams infillD Finished Cooled Heated 1 Main i 019 8834.7 Yes 0 0 i Yes Yes Yes 2 ' 2nd Flaor 1413 11304 No 5 4 1 Yes Yes Yes ; F�oo�s ; # Floor 1'ype Space Perimeter Perimeter Ft-Value Area Joist Ft-Va1ue Tile Wood Garpet 1 Slab-On-Grade Edge Insulatio Main 144.6 ft 0 1019 ft2 ____ 0.5 0 0.5 2 F{oor over Garage 2nd Floor ____ ____ 432 ft2 19 0.5 0 0.5 Roo� � / I Roof Gable Roof Solar SA Emitt Emitt Deck Pitch' V # Type i�Aateriais Area Area Color Absor. Tested Tested Insul. (deg} 1 Hip Gomposition shingles 1623 ft2 0 ft2 . Dark 0.92 Na 0.9 No 0 26.6 i ATTlC , / � v ' # Type Ventilatian Vent Ratia(1 in) Area RBS IRGC � 1 Full attic Vented 300 1451 ft2 Y N i i I I 1 1/4/201 6 4:10 PM EnergyGaugeC�USA-FlaRes2014 Sectian R405.4.1 Compliant Software Page 2 of 5 + �FORM F�405-2014 CEILING ' I # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type � 1 Under Attic(Vented) Main 34 Blawn 38 ft2 �.i 1 Wood ' � 2 Under Attic(Vented) 2nd Floor 30 Blown 1413 ft� 0.11 Wood I WALLS ' � Adjacent Space ��vity Width Neight Sheathing Framing Solsr 8eto 0 _ 1; N Exkerior Concret�Block-Int Insul Main 4.1 18 8 8 156.0 ftz 0 0.6 0' Z W Exterior Concrete Block-(nt 1nsul Main 4 1 20 8 8 173.3 ft2 0 0.6 0 ^ I S Facterior Concrete Block-lnt Insu! Main 4.1 38 S 8 8 335.1 ftz 0 Q.6 Q E Exterior Concrete Block-int Insul Main 4.1 33 8 8 8 29i:8 ft2 0 0.8 0 _ N Garage Frame-Wood Main 11 20 4 8 S 173.3 ftz fl.23 0.01 Q _ W Garage Frame-Wood Main 11 13 0 8 S 112.7 ft2 0.23 0.01 0 N Exterior Frame-Wood 2nd Floor t i 38 S 8 309.3 ftz Q23 0.6 Q W Exterior Frame-Wood 2nii Fiaor 11 40 8 8 325.3 ftz 0.23 0.6 0 S Exterior Frame-Woad 2nd Floor 11 38 8 8 3�9.3 iiz 0.23 0.6 0 1 E Exterior Frame-Wood 2nd Floor 11 40 8 8 325.3 ftz 0.23 0.6 0 ` ( DOORS � ( # 4rnt DoorType Spaoe Storms U-Value Width Neight Area Ft In Ft In � 1 N Insulated Main None .4 3 6 8 20 ftz _-( 2 E Wood Main tVane .46 2 8 6 8 17.8 ft� -� � � W!N[?OWS Orientation shown is the entered,Pro osed orientatian. f Wall Overhang V # Orrrt 2D Frame Panes NFRG U-Factor SHGC Area Depth Separafion lnt Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 5 ft 0 in 0 ft 4 in Drapes/blinds None 2 N 1 Vinyl Low-E double Yes 0.34 0.31 2.5 ft2 5 ft 0 in 0 ft 0 in Drapeslbiinds (Uone 3 W 2 Vinyi Low-E Double Yes 0.34 0.31 15.5 ft2 1 ft 0 in 10 ft 1 in Drapes/blinds None � � 4 S 3 Vinyl Law-E Doub(e Yes 0.34 d.31 46.5 ft2 1 ft 0 in 10 ft 1 in Drapeslbiinds None ' 5 S 3 Metal Low-E Double Yes 0.55 0.34 40.0 ft2 1 ft 0 in 10 ft 9 in Drapes/blinds None � 6 N ? Viny( Low-E Doubie Yes 6.34 d.31 1 BA ft2 1 ft 0 in 0 ft 3 in DrapesJblinds None ! � 7 N 7 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 1 ft 0 in 3 ft 9 in Drapes/blinds None ' 8 S 9 Vinyi Low-E Doubie Yes. d.34 d.31 46.5 ft2 1 ft�in 0 ft 3 in Drapeslblinds None GARAGE I # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed WaA Insulation � 1 432.1458 ft2 432.1458 ft2 49 ft 8.67 ft 0 I � � 1 1 i/4/ 016 4:10 PM � EnergyCaaugeC�USA-FlaRes2074 Seciion R405.4.1 Compliant Software Page 3 of 5 . i � �FORM R405-2014 INFILTRATION ; # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 i � 1 holehouse Proposed ACH(50) .000368 2349.5 128.99 242.58 .3401 7 HEATING SYSTEM - , I # System Type Subtype Efficiency Capacity Block Ducts� 1 Electric Heat Pump None HSPF:8.2 33.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts' 1 Central Unit None SEER:14 33.8 kBtu/hr 1014 cfm 0.75 1 sys#1 ' HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation ' � 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None I SOLAR HOT WATER SYSTEM FSEC Collector Storage � Cert # Company Name System Model# Collector Model# Area Volume FEF ' � None None ftz ; DUCTS � ` / �' --Supply---- ----Retum---- Air CFM 25 CFM25 HVAC#I V �I # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cooi 1 Attic 6 231 ftz 2nd Floor 40 ft2 Default Leakage 2nd Floor (Default) (Default) 1 1 ! TEMPERATURES � Prog�amable Thermostat:Y Ceiling Fans: � Coolir}g Jan r 1Feb r 1Mar Apr May Jun r Jul � Aug Sep Oct Nov Dec Heatir7g �Jan [X]Feb [X]Mar �APr f �May 4�Jun E�Jul 4�Aug f�SeP E�Oct �Nov �Dec� Venti Jan [ J Feb [x]Mar A r � Ma [ Jun Jul [ Au [ Se [X]Oct Nov Dec; i 'i s i I � i ' � ' � I �, , , 1 1/4/201 6 4:10 PM EnergyGaugeC�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 i � � J FORM A�05-2014 Therm�stat Schedule: HERS 2006 Reference HoLrs Schedule Type •1 2 3 4 5 6 7 8 9 10 11 12 Coolin�(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Coolin I(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heatin I (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heatin (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 � ; I . i 11/4/ 016 4:10 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 , I . FORI�A R405-2014 , ENERGY PERFORMANCE LEVEL (EPL) � DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index,the more efficient the home. , Zephyrhilis, FL, 1. Ne construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Sin le family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1269.30 ftz b.Concrete Block-Int Insul, Exterior R=4.1 956.22 ftz 3. Nu ber of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 286.00 ftz 4. Nur�ber of Bedraoms 4 d.N/A R= ftz 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic Vented R=30.0 14 z ( ) 51.00 ft 6. Co ditioned floor area(ftz) 2432 b.NfA R= ftz 7. Wi dows*' Description Area c.N/A R= ftz a. Factor: Dbl,U=0.34 189.00 ftz 11.Ducts R ft2 a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 231 HGC: SHGC=0.31 b. W-Factor: Dbl,U=0.55 40.00 ftz • S�HGC: SHGC=0.34 12.Cooling systems kBtu/hr Efficiency c. -Factor: N/A ftz a.Central Unit 33.8 SEER:14.00 HGC: d. -Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency HGC: a.Electric Heat Pump 33.8 HSPF:8.20 Are� Weighted Average Overhang Depth: 1.585 ft. Are�Weighted Average SHGC: 0.315 8. Flodr Types Insulation Area 14.Hot water systems a.Sfab-On-Grade Edge Insulation R=0.0 1019.00 ft z a.Electric Cap:50 gallons b.Floor over Garage R=19.0 432.00 ft2 b. Conservation features EF:0.95 c.NIA R= ftz None 15.Credits Pstat I certify�, hat this home has complied with the Florida Energy Efficiency Code for Building �gEST � Constr 'ction through the above energy saving features which will be installed or exceeded o� �'� � � ,y - o in this h�ome before final inspection. Otherwise, a new EPL Display Card will be completed ��i`-,,,�''� '-��'',,. ''�, based q�n installed Code compliant features. � ,`��-„;,�;;;;:�;;�`i,� ; 'I :J Builder ignature: Date: � �-���':`� �� ; Addres of New Home: ' ' City/FL Zip: � �, ��. cfla�.�� � �� ``��/� *N�te: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient � mo�-tgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) � 63�-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For inf rmation about the Florida Building Code, Energy Conservation, contact the Florida Building Comrnission's support , sta . *"L bel required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if rJot DEFAULT. 1 1/4/201 6 4:11 PM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 I ' ' FOR R445-2014 � ' Florida Department of Business and Professional Regulatians Residential Whole Buildin Performance and Prescri tive Metf�ods ADDFtESS: Permit Number: Zephyrhiils,F�, MAN�ATORV REQUI1RE14tIENTS See individual code sections for fu!! details. 0 4�1.3 Energy Pertormance Level(EPL)dispiay card(Mandatory). The building officia(shal�require that an energy performance levei(EPL) dtsplay card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law [S�ection 553.9085,Fiorida Statues]requires the EPL display card'to be included as an addendum ta each sales cantract far bath presolc3 and npnpresald residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of camponents installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to cfemonstrate compliance for the building.A copy of fhe EPt�disp}ay card can be faund in Appendix G. � RaIO2.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accardance with the requirements of Sections R402.1 through R402.4 4. Q R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2,The sealing methods between dissimilar materials shall allow for differential expansion and cantraction. � R402.A.1.1 tnstatiatian. The camponents af the building thermai enveiope as listed in Table R402.4.1.1 sha(1 be instailed in � accordance with the manufacturer's instructions and.the criteria listed in Table 402.4.1.1,as applicable ta the method of construction. Where required by the code afficial,an appeoved third party shaH inspect all components and verify comptiance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Glimate Zones 1 and 2,and 3 air changes per hour in Glimate Zones 3 through 8.Testing shall be condncted with a b(ower door at a pressure afi 0.2 inches w.g.{5d Pasca(s).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the cade afficial.Tesiing shal!be pertormed at any lime after creation a€all penetrations of the buitding therrnal envelape. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltrafion cantrol measures; 2, Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doars,if i�stalled at the time af fhe test,shatl be open; , 4.Exterior doors for continuous ventilatian systems and heat recavery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and refum registers,if i�stalled at the time of the tesf,shal[be fully apen. O R402.4.2 Fireplaces. New wood-buming fireplaces shall have tight-fitting flue dampers and outdoor combustion air. � , O R402.4.3 Fer�estratioa air leakage.Windows,skyligfits and siiding giass doors shaiE have an air infltration rate of no more than d.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA(GSA i01!l.S.2/A440 by an accrediied,independeni labaratary and listed and labeled by the manufacturer. Exception: Site-buiit windows,skyiights and doors. � Ft4Q2.4.4 Recessed lighting. Recessed luminaires installed in the building thermaf enveiope sha[I be seafed Eo limit air leakage , between conditioned and unconditianed spaces.All recessed luminaires shall be 1C-Yated and labele`d as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires sha!!be sealed with a gasket or caulk between the housing and the interiar wall or ceiling cavering. ❑ R 03.1.1 Thermostat provision(Mandatary). At least one thermostat shall be provided for each separate heating and caoling system. ', � R4�3.1.3 Heat pump supplementary heat(1Utartdatory}. Heat pumps having supplementary electric-resistance heat sha11 have controEs th�t,except during defirost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. � Fi4Q3.2.2 Seating(Mandatory}AH ducis,air handlers,and filter baxes and building cavities that form the primary air cantaittment passageways far air distribution systems shai(be considered ducts and plenum chambers,shaii be canstructed and sealed in accordance wi#�Section C403.2.7.2 of the Cammercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or ugh-in testing 6elaw. Du t tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section ' 55i.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: i 1.` Post-construction test:Total leakage sha(I be less than or equa(to 4 cfm(113 Vmin}per 100 square feet(9.29 m2}of conditioned flaor area : � when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All ' register boots shal!be taped or otherwise sealed duting the test. 2. I Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditianed floor area when tested �; , at a pressure differential of 4.1 inches w.g.(25Pa}across the system,.including the rnanufactttrer's air handler enc(osure.All registers sha{!be taped or otherwise sealed during the test.lfi#he air handler is not instalEed at the time of the test,total ieakage shall be iess than ar equai to 3 cfm �, (85 Umin)per 100 square feet(9.29 m2)of conditianed floor area. i F�ceptions: 1 The total leakage test is not required for ducts and air handlers Ipcated entirely within the building envelope. 2. Duct tesfing is not mandatory for huildings camplying by Section R405 of this code. 1 1141201 6 4:11 PM EnergyGauge�USA-FEaRes2014 -Secfion R405.4.1 Com Page 1 of 3 • • FORM R405-2014 I on in M NDATORY REQUIF�EMENTS - (C t ued) � R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) br below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. � �i403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can tum off the hot-water circulating pump when the system is not in use. � R403.4.3 Heat traps(Mandatory). Storage water"heaters not equipped with integral heat traps and having vertical pipe risers shall have �eat traps installed on both the inlets and outlets.Extemal heat traps shall consist of either a commercially available heat trap or a ownward and upward bend of at least 3'/z inches(89 mm)in the hot water distribution line and cold water line located as close as possible ti the storage tank. � R403.4.4 Water heater efficiencies(Mandatory). � R403.4.4.1 Storage water heater temperature controls . R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). . R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be tumed off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. 0 R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. . R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy il factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of • Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar pomestic Hot Water System and Component Test Protocol,Collectors in installed solar water I heating systems should meet the following criteria: I 1. Be installed with a tilt angle hetween 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. p R 03.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the �i FlQrida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. i O�tdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventitation system is not operating. I ' p R 03.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. 0 R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect ecjuipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation � such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the , equipment shall not be less than the calculated latent load. � �, 1 1 4/201 6 4:11 PM EnergyGaugeC�USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3 , �, FORIJI R405-2014 MA DATORY REQUIREMENTS - (Continued) 0 R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded pertormance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for retum side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and muiti-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than SO percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. 0 R403.6.1.2 Heating equipment capacity ' R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. . R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric bumers shall not be less than the design load calculated in accordance with Section R403.6.1. � R403.6.1.3 Extra capacity required for speciai occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ Rr303.7 Systems serving multiple dwelling units(Mandatary). Systems serving multiple dwelling units shall comply with Sections I Ci 03 and C404 of the Commerciai Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling , and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. � ❑ R�03.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and ' mground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy I requirements for portable spas shall be in accordance with ANSI/APSP-14. ' Q R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum � thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuousl burning ilot li hts. Y P 9 � R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160 Table 2 Standard Ratin Conditions-Low Air Tem erature.A test re ort from an inde g p p pendent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically tum off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. , 3. Where pumps are powered exclusively from on-site renewabie generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water.surtace or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or ' solar energy source computed over an operating season. ❑ RR404.1 Lighting•equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. 0 R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously buming pilot lights � R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Pertormance ONLY. Ceilings shall have minimum insulation of R-19.Where singie assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 1 /4/2016 4:11 PM EnergyGauge�USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 , � FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Prl ject Name: Galen Elevation D Builder Name: DRH Express Homes � St�eet: Permit Office: Ci�y,State,Zip: Zephyrhilis, FL, Permit Number: O�rner: Jurisdiction: Disign Location: FL,Tampa COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. • Air-permeable insulation shall not be used as a sealing material. Cei�ing/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned , attic spaces shall be sealed. I I Corne�s and headers shall be insulated and the junction of the foundation Wa Is and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be�sealed. Wi �dows, skylights and doors The space between window/door jambs and framing and skylights and � framing shall be sealed. Rirr� 'oists Rim joists are insulated and include an air barrier. Flo �Irs includin above- ara e Insulation shall be installed to maintain ermanent contact with undersi ( g 9 9 p de and�cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Cra� I space walls Where provided in lieu of floor insulation, insulation shall be permanently ' attached to the crawlspace walis. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or I unconditioned space shall be sealed. Nar�ow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled '� by insulation that on installation readily conforms to the available cavity s aces. Gar� ge separation Air sealing shall be provided between the garage and conditioned spaces. , Rec�essed lighting Recessed light fixtures installed in the building thermal envelope shall be � air tight, IC rated,and sealed to the drywall. Plu� bing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in � � . exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. ShoWer/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air � , I barrier installed separating them from the showers and tubs. ' _ Ele�trical/phone box on The air barrier shall be installed behind electrical or communication boxes or ' air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be I sea ed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have � gasketed doors � 11/4/2 16 4:11 PM. EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 � G�gs'"F Manual S Compliance Report �°b� � Q� �''� Date: Oct 07,2014 � � Entire House By: �. �iµ -�N�. Progressive Air Systems � 5907�DTEMS. asher ct, Port Richey,FI 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 I � � • ' • • For: DR HortoNExpress Lot 16 Blk 1 Siiverado, Zephyrhills, FI • • . . . De�ign Conditions utdoor design DB: 91.2°F Sensible gain: 24265 Btuh Entering coil DB: 76.0°F utdoor design WB: 77.1 °F , Latent gain: 3250 Btuh Entering coil WB: 63.0°F I�door design DB: 75.0°F Total gain: 27515 Btuh Indoor RH: 50% Estimated airflow: 1120 cfm Ma'�ufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP N�anufacturer: Carrier Model: CH14NA036"*"*A+FB4CNP036 Actual airflow: 1120 cfm S�nsible capacity: 26365 Btuh 109%of load L.�tent capacity: 4753 Btuh 146%of load TOtal capacity: 31118 Btuh 113%of load SHR: 85% • • • Des�ign Conditions O�tdoor design DB: 40.0°F Heat loss: 22889 Btuh Entering coil DB: 69.5°F Intloor design DB: 70.0°F Manufacturer's Pertormance Data at Actual Design Conditions E uipment type: Split ASHP M�nufacturer: Carrier Model: CH14NA036****A+FB4CNP036 A tual airflow: 1120 cfm O�tput capacity: 30307 Btuh 132%of load Capacity balance: 36 °F � S�lpplemental heat required: 0 Btuh Economic balance: -99 °F � ,I � � B ckup equipment type: Elec strip � ' M�ufacturer: Model: � Ac�ual airflow: 1120 cfm , O, put capacity: 7:5 kW 112%of load Temp. rise: 17 °F � �I , 'I The'above ui ment was selected in accordance with ACCA Manual S. � P �. wri htsofts 2D16-Nov-0412:32:12 ^_ 9 Right-Suite�Universal 2013 13.0.11 RSU18520 Page 1 �� ...les\E�ress homes\Galen 4EGB-3 ton New Code.rup Calc=MJ8 House faces: N ` ` Load Short Form Job: pK6ss�VF � a�� ��4 Date: Oct 07,2014 �•. Entire House 8,,: � �.� ;�:. , i �-•�. Progressive Air Systems s Is�Ms.�'' , 5907 Dasher ct,Port Richey,FI 34668 Phone:727-847-3898 Fa�c 727-815-3399 License:CAC033669 _ I � � ' � • • For: DR Horton/Express Lot 16 Blk 1 Silverado, Zephyrhills, FI � - • � • Htg Clg Infiltration Outside db(°F) 40 91 Method Simplified Inside db (°F' 70 75 Construction quality Semi-tight Design TD (°� 30 16 Firepfaces p Daily range - L Inside humidity (%) 50 50 Moisture difference(gr/Ib) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT M e Carrier Make ' Carrier T ade CARRIER Trade CARRIER M del CH14NA036"*"*A , Cond CH14NA036****A A RI ref 6803064 Coil FB4CNP036 AHRI ref 6803064 Ef iciency 8 HSPF Efficiency 11.7 EER, 14 SEER H�ating input Sensible cooling 25200 Btuh H�ating output 34000 Btuh Qa 47°F Latent cooling 8400 Btuh Te�nperature rise 28 °F Total cooling 33600 Btuh - Aqtual air flow 1120 cfm Actual air flow 1120 cfm Aif flow factor 0.049 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Sdace thermostat Load sensible heat ratio 0.88 � � ROOM NAME Area Htg load Clg load Htg AVF Clg AVF ' ' (ftz) (Btuh) (Btuh) (cfm) (cfm) , g�abkitchen 628 8291 7762 406 358 p try 42 582 194 28 g po�vder 33 6 9 0 0 flex 163 2707 2370 132 109 ' foyer 99 1503 1092 74 50 ' stairs 58 436 216 21 10 bed2 164 1437 1867 70 86 � bec�4 164 826 1425 40 66 bec�3 175 1491 1916 73 88 i ch e ' 4 5 6 0 0 ! ch' e2 5 6 9 0 0 � lau dry 53 349 911 17 42 � M �ath 168 1512 1733 74 80 wc� 25 30 42 1 2 ' a/c' 17 20 28 1 1 M ed 308 2557 3568 125 165 �� I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. � wri htsoft° 201&Nov-0412:32:12 ,..� 9 Right-Suite@ Universal 2013 13.0.11 RSU18520 Page 1 �A ...les\E�ress homes\Galen 4EGB-3 ton New Code.rup Calc=MJ8 House faces: N � `, c ase 3 4 7 8 0 0 b th2 68 540 442 26 20 s�airs2 39 47 gg 2 3 hall 195 408 457 20 21 ��� 70 129 143 6 7 E�tire House d 2478 22889 24265 1120 1120 O�her equip loads 0 0 Equip. Qa 1.00 RSM 24265 Latent cooling 3250 i TOTALS 2478 22889 27515 1120 1120 � ; � i ; I ' Calculations approved by ACCA to meet all requiremerrts of Manual J 8th Ed. �.� �' wrightsofta Right-SuiteO Universal 2013 13.0.11 RSU16520 2016-Nov-04 12:32:12 A(`,(�,A Page 2 ..IeslExpress homeslGalen 4EGB-3 ton New Code.rup Calc=MJB House faces: N � � FOR R405-2014 � RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professiona/Regulation ' Simulated Performance Alternative(Performance)Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include ' ❑ This checklist � ❑ A Form R405 report that documents that fhe Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, e-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of fhe compliance software tool, name of individual completing the compliance report(1 page)and an input summary checklist that can be used for field verification(usually 4 pages/may be greafer). ' , , ❑ Energy Performance Level(EPL) Display Card(one page) ❑ Mandatory Requirements(three pages) ' Required prior to CO for the Pertormance Method: ❑ Air Barrier and Insulation Inspecfion Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed � Form R405 Duct Leakage Test Report(usually one page) , � ! � I � � , � � � � EnergyGaugeO-USRCZB v5.1 1 1/4/201 6 4:09:36 PM Page 1 of 1 � i. Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. 9. No electric, plumbing, mechanical, or framing shall be covered without an inspection and � approval first. � 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board"-shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. A112008 N.E.C. Codes will be enforced. , 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 � � 22. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. F.F.E.-Finished Floor Elevation �' F.B.C- Florida Building Code Sth Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008) i