Loading...
HomeMy WebLinkAbout17-18229 CITY �F ZEPHYRHILLS 5335-8TH STREET , � - ' � ��i3)�so-oo20 18 � ` BUILDING PERMIT SINGLE FAMILY RESIDENTIAL - PERMIT INFORMATION �� LOCATION INFORMATION [�ermit#:18229 Issued: 3/06/2017 Address: 6592 PADEN WHEEL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. ' Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 329,646.50 Total Fees: 11,678.19 Subdivision: SILVERADO Amount Paid: 11,678.19 Date Paid: 3/06/2017 Parcel Number: 05-26-21-0070-00300-0080 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 15550 LIGHTWAVE DR Address: 4600 W. CYPRESS ST STE 200 CLEARWATER FL 33760 TAMPA FL 33607 Phone: (727)479-1740 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 3,235 SQ FT APPLICATION FEES BUILDING FEE 1,281.56 ELECTRICAL FEE 265.05 PL MBING FEE 176.70 MECHANICAL FEE 123.69 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 i� � � ����. �S—�Q,cI� P.�twrC� �.e,7'� �l�"—� 7 � Ins ections Re uired FOOTER 2ND ROUGH PLUMB MIS INSU TION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTiCE: In addition to the requirements of this permit, there may be additional restrictions applicable to this properly that may be found in the public records of this county, and there may be additional permits required from other governmental � entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney I before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application.All work shall be pertormed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. ' NO OCCUPANCY BEFORE C.O. � CONTRAC ORS SIGNATURE PERMIT OFFI � P RMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 + ' ' Building Department ' ' L�!'/� �iJ t�/-'>Cl� /f�/f�✓�/�n�/�J�''•r1 Date Received 1� [b�7 phone Contact for Permittin . 813 363 _ 2891 Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700 Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name N�A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 6592 Paden Wheel Street LOT# 0080 SUBDIVISION Silverado Ranch Subdivision Ph 2,3,84 pqRCEL ID# 05-26-21-0070-00300-0080 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED II✓ II NEW CONSTR e ADD/ALT 0 SIGN 0 � DEMOLISH � INSTALL REPAIR PROPOSED USE � SFR Q COMM 0 OTHER TYPE OFCONSTRUCTION � BLOCK Q FRAME � STEEL � DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF 3235 SQ FOOTAGE 242� HEIGHT 1 Story ITrTrTITrTI"TTrI"ITTTrI"ITTTrTrTTrTrTrTTr1'7��TTr1" f BUILDING $ p ` �/ VALUATION OF TOTAL CONSTRUCTION s '�/ 'ELECTRICAL $ � PROGRESS ENERGY 0 W.R.E.0 ' � � AMP SERVICE �PLUMBING $ �� e �„r,�� � ��i� ���/ �MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION � . « OGAS � ROOFING Q SPECIALTY � OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA �YES �O �.1 -d--F-1--1-1--1-�1--�1-1--1-A-�1--1-1--1-1-1--1-{--F-{-F-��1--1-1--��1--���--Ha-1--1--F-�--1-1--1-1--4-�1--f-FI--1--F-1--1-1--1--l-1--��1--E-E-�--1--F- BUILDER �✓ COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4600 W.Cypr ss St.Ste.200,Tampa,FL 33607 License# CGC1518166 ELECTRICIAN � COMPANY Edmonson Electric, �IIC. SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 1034 Skipper oad,Tampa, FL 33613 License# EC13005408 PLUMBER �� COMPANY Bayonet Plumbing, Heating &AC, inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, Bayonet, FL 34674-5308 �icense# CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating & AC, �C1C SIGNATURE �/ REGISTERED Y/ N FEE CURREN Y!N Address P.O. Box 530 , B onet, FL 34674-5308 �icense# CAC058062 OTHER — COMPANY �v/�rl�� SIGNATURE REGISTERED Y/ N FEE URREN Y/N Address 4211 Shoal Li Blvd, Spring Hill, FL 34607 License# CCC057991 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIDIIIIIIIIIIIIIIIIIIIIIIIItt1111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Pians plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Pians w/Silt Fence installed, Sanitary Facilities&1 dumpster Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. '*""PROPERTY SURVEY required for all NEW construction. ..f.-1-4L1-.{-.4_I--�1-1--4_I--��L-�..1_��f..1..L�4�1-��{.-L_�1..��1-1-�--f��L..4_���1--��L..{�1--����I..f..L1.��4�1--f..f-{� Directions: Fill out application completely Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) "" Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A!C Fences(PIoUSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW ' � . NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any ' applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entifled to permitting privileges in Pasco County TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES� The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release If the project does not involve a certificate of ocGupaney or final power release, the fees must be paid prior to permit issuance Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended) If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the buiiding permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTA FINANCING, CONSULT WITH YOUR LENDER OR AN AT .ORNEY BEFORE RECORDING YOUR NOTICE OF CO ENCEMENT. FLORIDA JURAT(F.S.117.03) _� '�./ OVtiNER OFt AGENT------ - _ ._ CONTRACTOR Subscribed and sworn to(or affirmed) efore me this Subscribed and swoin to(or affirmedj efore me Ihis— - -- • _ �i-uec-�i n by Paul Sweene Z�-oe=-,fi by paul Sweene Who is/are personally known to me Who is/are personally known to me o identification. as identification. Notary Public Notary Public i Commission No._ ��_ Commission No._ i Name of Notary typed, rinted or sta ! Name of Notary typed,printed or stamped __ ,-", ,�o;a:Y:�"e�c: STEPHANIE FARMER 7 ' *;�•,�: Commission#FF 183848 ....� Expires February 15,2019 Y:>"' —�'�'°�"°"" ,:;, •'�^"• r�� STEPHANIE ''�'.F„pt��°:�`� BondedThruTroyFolnlnsurance8�0-395-70i9 ?*2o k, Commi FAFiMER =;��,o�Po: ExpiresSFebr ary 15,2019 Bonded ihm Tro Fein�neurenoo 800- Y 385•7019 Illlllllllllllllllllllllllllllllllllllllllllllllllllllllllll � , 2017031380 Rcp1.;1843323 Rec: 10.00 � DS: 0.00 IT: 0.00 ' 03/06/2017 K. D. K., Dpty Clerk PRULfi S 0'NEIL,Ph D.PRSCO CLERK 6 COMPTROLLER 030R6BK 1C��0�m PG 2226 Permit No. Parcel ID No 05-26-21-0070-00300-0080 NOTICE OF COMMENCEMENT Stale of Florida County ot Pasco THE UNDERSIGNED hereby gives nolice lhat Improvement will be made to certain real property,and in accordance with Chapter 713,Florida Slatutes, the following information is provitled in lhis Notice of Commencemenl: 1 Descriplion of Property Legal SILVERADO RANCH SUBDIVISION PHASES 2 3 S 4 P8 73 PG 59 BLOCK 03 LOT OB s��ee�naa�e55: 6592 Paden Wheel Street Zephryhills FL 33541 2. General Description of Improvement Single Family Residence!Pool I Screen Enclosure/FenCe 3. Owner Information: Lennar Homes,LLC. Name aFnn w����P��St ste 00 Tamna FL��607 Address City State Inlerest in Propedy Name of Fee Simple Tilleholder N�A (It other than owner) Atldress Ci�y State Contractor• Lennar Homes LLC Name 460D W Cypress St Ste 200 Tampa FLy33607 � Address Cily State Contractor's Telephone No. 813.574.5700 5. Surety: r'��:'� N/A Name Q {— W � Z U � Address Cily State O W �� .� � Amount of Bond: S Telephone No. (� � � � � J � zU �~ —�J � 6. �ender: N/A C� Name �.�� = Q N,(� � Address City State ��LL!z Uj a 'W Lender's Telephone No. r � _ — J g � F�- � �� ¢�0 7 Persons within the State ot Florida designated by the owner upon whom notices or olher documents may be served as provided by !1.(O � (� Seclion 713.13(1)(a)(7),Florida Sfalules: ��} �� � � Lennar Homes L C � � Q W � Y Name V Q 0 �0 � 4600 W CvAress St Ste 200 Tamoa FL�3607 Q f—Z� V U �1 Address Cily Stale Q }. U m Q U � Telephone Number of Designaled Person: 813.574.5700 � � LLl � � V- � !— Q' a z �J B. In addition lo himself,the owner designates N/A °f— � W O O = Q z to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. U (� �r � 7elephone Number of Person or Entity Designated by Owner o'O Z Q� O W cq•Q W C�J � 9. Expiration date of Notice of Commencemenl is one year from lhe dale of recording uniess a different dale is specified: � w J W � WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT Q � � � z ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN � 2 a' Z — � RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY A NOTICE OF COMMENCEMENT MUST BE � f— F— Q� Q } ' RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSUIT a ,0] WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT 10 STATE OF FLORIDA �� ���L���y • T. 1�3' COUNTY OF PINELLAS Signature of Owner or Owner's Authorized OKcer/Director/Partner/Manager � � Vice President �.' , ti , � Signatory's Tille/OKce �� �� ,�� � The toregoing instrument was acknowledged before me lhis 2� day of Decembef�+�V,by • 01 � � � Steve Smith as VicC Pfesid2nt (lype of aulhority,e.g.,oKcer,truslee,allorney in fact)tor � o � � • � Lennar Homes L�C (name of pa instrumentwas executed). � � �� 'ti • � Personally Known�OR Produced Identification❑ Nolary Signature _ ' � Type of Idenlification Produced Name(Print) ` � ��� o •�@ Verificalion pursuant lo Seclion 92.525,Florida Slatules. Under penalties of perjury,I declare that I have reatl the foregoing and thal the facls slaleG in 3� •� �y It are We lo the besl ot my knowledge and beliet. � °:��'�yo�., STEPHAPlIE FARMER 9 ure of Natural Person Signing Above � =,f� �': Commission#FF 183848 :,��.�,;;; Expires February 15,2019 wpdata/bcslbcs form ''�o,.;$�� eom.einNrr%Fwi�.�esoa�s�a+� � � , RASCO C.OUNTY, FLORIDA ' Permit No. ZZ ; Date Permitted ��..���] Builder Name/Owner Name �t�����ayrt�2.� Control# ' County Parcel No. �� -Z�_Qp"7�_�aA �, �D SubDiv: �� � , AddresslLocation ,�t��2. �R�p� ���� �-i-- , Classification/Type of Use _ �'r�il�j�� �,�4 �� TRAN�PORTATION IMPACT FEE Rate: -_ � : , - Sq Ft Unit: 3� 235 Exempt [] Yes � No How Determined � Impact Fee Amount $ ���Z�vV Zone No. __ TAZ: SCHOOL IMPACT FEE . Account (056) Single-Family Detached House Amount $ �� 8?�, Z� (057) Mobile Home (058) Other Resfdential . � 123) Collection Fee � Exempt [� Yes Q No How�Determined � PARKSAND RECREATION FEE Land Account Land Credit Land Total � . � Recreation Account __ Recreation Credit Recreation Total � Zone . TOTAL AMOUNT $_7 6 9��"� Exempt � Yes �] No How Determined � • . LIBRARY FEE l.and Account Land Credit . Land Total , Facility Account Facility Credit ' Facility Total , Exempt � Yes [] No How Determined __ Tofal Amount�_ � lRESOURCE FEE ERU � .4TOTAL AMOUNT � Prepared By ' Checked By , NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE � RECEIPTED FOR BY A CENTRAL PERMIT7'NG OFFICE OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence,but simply recelpt of a copy of this form,placing the building permit owner on notice ot this assessment and the conditions of payment for same. iDATE RECEIVED BY ECEIPT NO. __ pATE _� gY , � Lennar Homes-6592 Paden Wheel St-3,235 sq ft o umn SQ. FEET PRICE MAIN OR LIVING: 3,235 $ 101.90 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 329,646.50 FEE SHEET $ 1,178.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,281.56 ELECTRICAL: $ 265.05 PLUMBING: $ 176.70 MECHANICAL: $ 123.69 SUB-TOTAL $ 1,847.00 TOTAL $ 1,847.00 SEW ER: na WATER: na IRRIGATION: $ - TOTAL: $ - WATER METER: na IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: na INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,400.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 " TOTAL: $ 11,678.19 i , , � , 6592 Paden Wheel St o umn SQ. FEET PRICE UNDER ROOF: 3,235 $ 101.90 OTHER: - $ - VALUATION $ 329,646.50 FEE SHEET $ 1,178.00 ADDRESS $ 40.00 ' DRIVEWAY $ 40.00 BUILDING: $ 1,281.56 ELECTRICAL: $ 265.05 PLUMBING: $ 176.70 MECHANICAL: $ 123.69 SUB-TOTAL $ 1,847.00 TOTAL $ 1,847.00 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: - PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,400.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,678.19 . , i iiiiii iiiii iiiii iiiii iioii iiiii iuii iiiii iii�i iiiii iiii uii � � ' 20170297�3 Rept: 1842616 Rec: 35.50 This Instru�nent Was Prepared DS:�654.8o IT: o.o0 By And�hould Be Returned To: 03/o3/2oi� eRecording Lee E.Nelson,Esq. PAULA S.O'NEIL,Ph.D.PASCO CLERK 8 COMPTROLLER Shutts&Bowen LLP 03/03/2017 �0:41 AI�i i ot 4 4301 W. Boy Scout Blvd_, Suite 304 Tampa,l�lorida 33607 OR BK 9�[�L�, PG ��L7� Parcel 1 d N um bers: 04-26-2 i-OU70-40100-OQ40;44-2fi-2l-Op7Q-00100-(?2G0; 04-26-21-ao7o-o02�o-4os�;OS-�21-Q(�?7�U✓-UU3UU-OU80;OS-2G-21-0U70-004Q0-01-00�� � �� � �D� �o [�-�� � � �� �.��� ��. ��.� � , p�d��. � , �� � � ��� � ✓ r����.�. �..�.G.�:�� ���f�. �� � ,���.�.__ t�s� 2 ����- ��� ��" �s i SPECIAL WARRANTY D�Ell This Special Warranty f�ecd {this "Deed"}, exec;ttted on this ��day of � t�� �r , 20I7, by DUNE FL LA1VI� i SUB, �,1,C, a Delaware limited liability company ("Gran or"}, whose mailing address is 2502 N. Rocky Point T)rive, Suite IOSQ, Tampa, �lorid��t 33647, to LENNA,R Ii4MES, LLC, � Fiarida limited liability company ("Grantee"), whose maiiing address is 4b00'1�est Cypress Street, Suite 200,Tampa,Plorida 33607. WITNESSETH; That Cirantor, for and in cansideration of the stun ai ten dollars ($14.00) and other good and valuable consideration io Grantar in hand paid by Urantee, the recaipt and sufficiency of which is hereby acknowledged, has granted, bargained, and sold to Grantee and UrAntee's successars and assi�;ns forever, the real property situate, lying, and being in Pasco County, �loricl��t, and described in �xh�_ 'baf"A_9 attached hereto (the"Properiy"). TOGETHER with all of the Grantor's rights, titte and 'uiterest in and fo aIl licenses, approvals, fenements, hereditaments, and Appurienances belonging or in any way appertaining to the Pr�perty, TO H�VE�1N17 T� TIUL,D the same in fee simple forever. And Grantor hereby speciatiy covenants with Grantec that Ura��tor is lawfully seized of the Property in fee simple, and hercby specially r�varrtints the titic to the Yroperty and wi 11 de#'cnd the same against the l�wful claims of all persans claiming by, through or under Grantor, but not atherwise, and that the Property is bein� conveyed to Grantee subject to al� zoning and governmental re�ulaiions, all matters which a physical inspection of the Property wauld disclose, and those permitfied exceptions identif ed in Exh�,�bit"B"atta�hed hereto and made a part hereof, rovided-tlj�foreg�irr�--shaH�at serve-to��sose-t e same. - [SIGNATURE QN 1���T PAGE] OR BK 95�4� pG �7�� � � . 3 of 4 Exlubit"A" , Lesal Dcscr'spiion Lc�ts 4 and 26, Block 1 of SII,VER.A,DO RANCH SUEDIVISION PI�ASES 2, 3 & 4, accozdin� to the Plat thereof as rccoxdeti in Plat Bootc 73, Page(s) 59, of the Public Records af Pasco County,Florida. ' Lot 8, Block 2 of SILVER.ADO RANCH SUBDIVISION PHASES 2, 3 & 4, accarding to the Plat thereof as rer�orded ' �n Plat Book 73 Pa s 59 , ge{ ) , of the Public Records of Pasco County, Flor�da Lot 8, Bloc� 3 of ST�,VERADO RANCH SUBDIVISI�N PHASES 2, 3 & 4, according ta the Plat thereof as reearded in Piat Book 73, Page(s) 59, of the Public Records of Pasca County, Florida. Lot 13, Block 4 of SILVERAD� RANCH SUBDIVISION PHASES 2, 3 &4, accordin�to the Plat thereof as recorded in .Plat Baak '13, Page(s) 59, of the Public Rccvrds of Pasco County, Florida. i OI2 BK ���� PG '�� � � � ' 4 oE 4 Exhib�t"B" Pcrmitted Excentions 1. T�xes and ass�ssmer►ts£or the year Z017 and subsequent years, which are not yet due and payable. 2, Nc�tice of EstabSislamer�t af the Silveradt� Community I?evelapment District rect�rded in �ff"icial T�ecords Bnok 9135, Page 1443; C}rdinance No. 124i-14 recorded in Official Records Book �123, Page 3 and r�-reet�rde�I in Official Recards �vvk 9179, Page 3372 and re-recorded in t3ffccial Recards Boak 9399,Pag�2G67,af the 1'ub1iG Records of l�asca County,Flarida. 3. Oxdina�zce No, 1247-15.recorded in Officiat Records Book 9170, Page 87, of the Public Recc�rds of Pascca Caunty,Florid�. ; 4. T�tms and conditions of #he Declaratic�n c�f Consent tc� Jurisdictic�n r�f the Silverado Cammunity Development Ilistrict, Impositian of Special.Assessments,and Impasition of Lien of R�c�ard recorded in C?fficial Recards Baok 9388, Page Z27, af ths Public Rec�rds of�'asc�, County,Florida. i � 5. T�ns and c�nditions of that certain Lien of Recorci, Disclosuire of Public Fina.ncin�;, and Maintenanee of Iz�apx4vements of tl�e S�.verado Commu�ity Develapment District (Series 2016A-1 Bonds� recc�rded ��n Official Recflrds Book 9388, Page 241, of the Public Records of Pasco Co�nty,Flarida. 6. Tenns and co�ldit�ons c�f that certai�l Lieu uf Record, DisclQsure c�f Public Finat�cing, and Maintenance af Imprvvements af the Silverado Cor�nunity Development District (Series 2fl16A-2 Bonds) recorded in t)f�i+cial Re.�t�rds BQok 9388, Page 246, af the Public Recc}rds vf Pasco Co�ty,F�orida. 7. Restrictians, dedicatians,conditions, resexvations, �asemeiits and other rnatters shown on I the plat of Silverado Ranch Subdivisian Phases 2, 3 & 4, as recorded ir� Plat Bc�c�k 73, Page�s} 59, of tlie Public Records of Pasco Cc�unty, Florida, but delet�rag �,ny cavenant, candition or restriction indicating a preference,limitation or diseriminatat�n based oan race,colar,religion,sex, handicap, faenilial status or national ori�in to the extent such covenants, oonditions or restricrions vifllate 42 USC 3b44(c}. 8. Declaratic�n of Covena��ts, Conditio�s and Restrictions, including any amendments 4r modificatsons tkiereto,recozded in Of.ficial Records Bvok 9443,Page 1105, of the Public Rec�rrds of Pastx� Cou�.ty, Florida, but deleting any cc�venaut, cQndition or restriction indicating a ______.._pre€erez�ee;-�irrzkt�ion-ox�discrimina#zan--bas�ci�o�-rac��ol�r, re igio�sex,— a�n ica�r, amx iall�" status or nationa,l arigxn to the extent such covenants, canditions or restrictia�s violate 42 U�C 3604{c}. II TYADCICS 214331y2 128U53.0162 I . OR BK �5�4 pG ���� � � 2 of � j�,r j����r��g �y�EREOF, Grantor has ��ecuted this Deed on tlie date first a�ove written. DUNE FL LAND T S�1B,LLC, a Delaware limited liability cornpany .��.. ~ . Si�nature of ' ess 1 By; -�- �' John M. Ryan,Manager � �R . Printed�N e of Vditness 1 (�[.07tsti+✓ Signature of Witness 2 ��� �l'D►21n. Printed Name of Wimess 2 STATE OF FLOIZIDA ) }ss.: COUNTY pF HILLSSOROUGH } The foregoin�instrument was acknowledged before me thisl� day of /`=;�,��a���- 2017, by Jaiw M. Ryan as Manager of DITNE FLC L�1D I SUB, LLC, a Delaw�a �mited liability company on behalf of the company, who ��is personally kaown fo me or � has produced ��-- �� for identificatio . ' ..f'f .i Notary Publ' My Commission Expires: y"�/���� rr '��r.�:r.�Y,xa'+�•�.;oG9`Q '�..�5• —���a�.�c - q .�:`����a-,,, I(�LLEY REr,q��� r°f•' d��: fdotary Public-St�t�of�lorida - �,•� T'���x<,67y Comrrt.fxpiros May 31,2017 � �;7r'"-'��o;� Commission�EE 872A40 ` �'%++����`"� Bart�ed Tlirt�uph hJat'sonal t�otary Assn. ���'�wa',�+''�,'`ay.s"'-�cv,at�yr ' . . �c,- . f I OS-26-21-0070-00300-0080 � Pasco County Properiy Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, March 4, 2017 I Parcel ID 05-26-21-0070-00300-0080 (Card: 001 of 001) Classification 00 -Vacant Residential Mailing Address Property Value DUNE FL LAND I SUB LLC Ag Land $0 C/0 HAWK MANAGEMENT CO LLC Land $26,805 2502 N ROCKY POINT DR STE 1050 ROCKY POINT FL 33607-5995 Building $0 Physical Address Extra Features $0 6592 PADEN WHEEL ST ZEPHYRHILLS, FL 33541 Leqal Descriation (First 4 Lines) Just Value $26,805 SILVERADO RANCH SUBDIVISION Assessed (Non-School Amendment 1) $26,805 PHASES 2, 3 &4 PB 73 PG 059 BLOCK 3 LOT 8 Taxable Value $26,805 7urisdiction City of Zephvrhills Land Detail_(Card: 001 of 001)_�___� __ Line Use De pcs �r tion� Zoning_ _Units i Type � Price ,Condition; Value ___ 1_ �_ �_ 0100 __ SFR __MPUD _6,000.00 SF _ i _$4_25 00 j $25,500_ 2 ; 0100� SFR� MPUD � 3,956.00 SF � $0.33�1.00 � $1 305 I � I i Additional Land Information Acres I 0.23 � Tax Area 30SI �EMA __ �esidential Code SLVRLPI Code Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved __^___ ___ Extra Features (Card: 001 of 001)T______ _ Line --r--_..___._.---�_.__— ______ ____ ___r _ Description___� Year `�_ __ Units_�_ �__v_Value_ No Extra Features Sales Historv-See All 5 sales Previous Owner: � _ Month/Year Book/Page �— Type �DOR Code Condition ;� Amount 09/2011 �606 / 3376 i Warranty Deed 05 Vacant � Multi-Parcel Sale --- ---�-----------�Y_ __--' -- ----�--------------- __.______ ---- ----- -�- -- � ------ 05/2010 � 8373 / 1912 Certificate of Title 12 , Vacant � $0 -- --....--------�----- -._._ _---_�—�_—_�.--_-------�-------� 07/2005 6725 / 1059 Quit Claim Deed } 1 Vacant �� $0 � ' ', http://appraiser.pascogov.com/search/parcel.aspx?parce1=2126050070003000080 3/6/2017 O� ' ' . � ' kL�71U� «s� �� ''f,��.� . , �7 '� � City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: �1'�-tiLc�ir' �G'�I�' Date Received: , ) � L �—l '� � site: � ��� ��et� �`L�°��S'7— � Permit Type: �v G�_���i Approved w/no comments:❑ Approved w/the below comments: � Denied w/the below comments: ❑ ��� S�'�� �� i This comment sheet shall be kept with the permit and/or plans. �-a0- � � Kalvin Switzer lans Examiner Date Contractor an or Homeowner (Required en comments are present) Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8"above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. 9. No electric,plumbing, mechanical, or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless ' protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. ' 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. A112008 N.E.C. Codes will be enforced. 23. Tamper- Resistant Receptacles 'in accordance with 406.11 of the 2008 N.E.0 22. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. F.F.E.-Finished Floor Elevation F.B.C-Florida Building Code 5�'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008) ` =�; � ' � 308 ' FORNf R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2421 sf ADS drawn Builder Name: Lennar o es Sl�,n street: 6592 Paden Wheel Street Permit Office: �(i r� c� City,State,Zip: ,FL, Permit Number � (g 2- Owner� Lennar Homes Jurisdiction: � ���� Design Location: FL,Tampa 1 New construction or existing New(From Plans) 9. Wall Types(2344.6 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.0 1874.90 ftz b.Frame-Wood,Adjacent R=11.0 469.69 ftz 3. Number of units,if multiple family 1 c.N/A R= ftZ 4 Number of Bedrooms 4 d.N!A R= ftz 10 Ceiling Types (2421.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1901.00 ftZ 6. Conditioned floor area above grade(ft2) 2421 b.Cathedral/Single Assembly(Vented) R=30.0 520.00 ftZ Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ 11 Ducts R ftZ 7 Windows(230.7 sqft.) Description Area a.Sup�Attic,Ret:dining rm,AH:laundry 6 483 a. U-Factor Dbl,U=0.54 140.00 ftZ SHGC' SHGC=0.31 b. U-Factor• Dbl,U=0.58 64.00 ftx 12.Cooling systems kBtu/hr Efficiency SHGC� SHGC=0.32 a.Central Unit 34.8 SEER:15.20 c. U-Factor• Dbl,U=0.56 26.67 ftz SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor N/A ftZ a.Electric Heat Pump 32.8 HSPF:8.70 SHGC: Area Weighted Average Overhang Depth: 4.283 ft. Area Weighted Average SHGC: 0.309 14 Hot water systems I B. Floor Types (2420.2 sqft.) Insulation Area a.Electric Cap:40 gallons I EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 2420.20 ftz b. Conservation features b.N/A R= ftZ None c.N/A R= ftz 15.Credits Pstat Glass/Floor Area. 0 095 Total Proposed Modified Loads. 71.47 pASS Total Baseline Loads: 73.07 I hereby certify that the plans and specifications covered by Review of the plans and �"C'H��7`.��. d. ,..':q �. this calculation are in compliance with the Florida Energy specifications covered by this ' '+v.., _,:; p�, , fr�� {=�i4 Code. calculation indicates compliance c,�'�frr, ' r` n^ /. with the Florida Energy Code. � '�� � i � �' tr,fri�%;;::;�':.-'��"�'.,�� � PREPARED BY: �QV� �����'c Before construction is completed �� '4 � this buildin will be ins ected for ���' " � DATE. 9 P r:� ����;� � compliance with Section 553.908 � � � , � I hereb certi that this buildin as desi ned is in com liance Florida Statutes. �S Y fY 9, 9 P �!_:. � �� , with the Florida Energy Code. �'��W�'�` OWNER/AGENT: BUILDING OF CI . DATE. DATE. " - Compliance requires certificati n by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance.with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. 1/3/2017 8:35 AM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 6 � � � ' ' � 308 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2421 sf ADS drawn Builder Name: Lennar Homes street: 6592 Paden Wheel Street Permit ottice: City,State,Zip: ,FL, Permit Number� Owner Lennar Homes Jurisdiction: Design Location: FL,Tampa 1. New construction or existing New(From Plans) 9 Wall Types(2344.6 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.0 1874.90 ftz b.Frame-Wood,Adjacent R=11.0 469.69 ftz 3. Number of units,if multiple family 1 c.N/A R= ftZ 4 Number of Bedrooms 4 d.N/A R= ftZ 5. Is this a worst case? Yes 10.Ceiling Types (2421.0 sqft.) Insulation Area Z a.UnderAttic(Vented) R=30.0 1901.00 ft 6. Conditioned floor area above grade(ftZ) 2421 b.Cathedral/Single Assembly(Vented) R=30.0 520.00 ftZ Conditioned floor area below grade(ft2) 0 c.N/A . R= ft2 11 Ducts R ft� 7. Windows(230 7 sqft.) Description Area a.Sup:Attic,Ret:dining rm,AH:laundry 6 483 a. U-Factor Dbl,U=0.54 140.00 ft2 SHGC SHGC=0.31 b. U-Factor Dbl,U=0.58 64.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC• SHGC=0.32 a.Central Unit 34.8 SEER:15.20 c. U-Factor• Dbl,U=0.56 26.67 ftZ SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor� N/A ftz a.Electric Heat Pump 32.8 HSPF:8.70 SHGC• Area Weighted Average Overhang Depth. 4.283 ft. Area Weighted Average SHGC• 0.309 14 Hot water systems 8. Floor Types (2420.2 sqft.) Insulation Area a.Electric Cap�40 gallons EF 0.950 a.Slab-On-Grade Edge Insulation R=0.0 2420.20 ftZ b. Conservation features b N/A R= ft� None c.N/A R= ftz 15.Credits Pstat Glass/FloorArea. 0.095 Total Proposed Modified Loads: 71.47 pASS Total Baseline Loads: 73.07 I hereby certify that the plans and specifications covered by Review of the plans and ���1cSE S7'.q�.�, this calculation are in compliance with the Florida Energy specifications covered by this �v ,�.{ '�i=�' p�,�, _ Code. - calculation indicates compliance �'�;i„ `' _�'� �+ . with the Florida Energy Code. F+ ��r�rr.°�%� �.+�E".�,°:���`"*�,a�� �"� /. � ��� .• �..«. � . PREPARED BY �aV� f�Wl,j'l�Vl Before construction is completed DATE: this building will be inspected for � �'���! � � � compliance with Section 553.908 ' * � � I hereby certify that this building,as designed, is in compliance Florida Statutes. . � . ��� with the Florida Energy Code. �D yy�'�� OWNER/AGENT: BUILDING OFFICIAL. DATE: � � ' DATE. � � - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESPIET Standards,is not greater than 0.030 Qn for whole house. 1/3/2017 8:35 AM EnergyGaugeO USA-FlaRes2014 Section R405 4 1 Compliant Software Page 1 of 6 r + FORM R405-2014 PROJECT Title: 2421 sfADS drawn Bedrooms: 4 Address Type: StreetAddress Building Type: User Conditioned Area: 2421 Lot# Owner• Lennar Homes Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 315 Street: Permit Office: Cross Ventilation: No County: Pasco Jurisdiction: Whole House Fan: No City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume � 1 Entire House 2421 22767.3 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 master bdrm 278 2585.4 No 2 1 1 Yes Yes Yes 2 o wic 57 530.1 No 0 1 Yes Yes Yes 3 privy 19 176.7 No 0 1 Yes Yes Yes 4 o bath 122 1134.6 No 0 1 Yes Yes Yes 5 dining rm 325 3022.5 No 0 1 Yes Yes Yes 6 foyer 49 455.7 No 0 1 Yes Yes Yes 7 living rm 193 1794.9 No 0 1 Yes Yes Yes 8 laundry 77 716.1 No 0 1 Yes Yes Yes 9 bdrm 2 154 1432.2 No 1 1 1 Yes Yes Yes 10 bath 2 47 437.1 No 0 1 Yes Yes Yes 11 bdrm 3 161 1497.3 No 1 1 1 Yes Yes Yes 12 bdrm 4 166 1543.8 No 1 1 1 Yes Yes Yes — 13 bath 3 54 502.2 No 0 1 Yes Yes Yes 14 kitchen 126 1423.8 Yes 0 1 No Yes Yes 15 nook 200 1860 No 0 1 Yes Yes Yes 16 family rm 393 3654.9 No 0 1 Yes Yes Yes � FLOORS #- Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio master bdrm 41.8 ft 0 278 ft2 ___ 0 0 1 2 Slab-On-Grade Edge Insulatio o wic 9.5 ft 0 57 ft� -- 0 0 1 1/3/2017 8:35 AM Ener Gau eO USA-FlaRes2014 Section R405.4.1 Com liant Software Pa e 2 of 6 I 9Y 9 P 9 =1 � , '� FORM R405-2014 FLOORS # Fioor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 3 Slab-On-Grade Edge Insulatio privy 3.5 ft 0 18.8 ft2 ___ 1 0 0 4 Slab-On-Grade Edge Insulatio o bath 10 ft 0 122.4 ftZ ___ 1 0 0 5 Slab-On-Grade Edge Insulatio dining rm 7 ft 0 324.5 ft2 e__ 0 0 1 6 Slab-On-Grade Edge Insulatio foyer 14 ft 0 49 ftZ ___ 1 0 D 7SIab-On-Grade Edge Insulatio living rm 31.5 ft 0 192.9 ftZ �__ 0 0 1 8 Slab-On-Grade Edge Insulatio laundry 8 ft 0 77 ftZ ____ 1 0 0 I 9 Slab-On-Grade Edge Insulatio bdrm 2 25 ft 0 154 ftz ___ 0 0 1 10SIab-On-Grade Edge Insulatio bath 2 5.3 ft 0 47.3 ftZ �__ 1 0 0 11SIab-On-Grade Edge Insulatio bdrm 3 14.3 ft 0 160.8 ftZ ___ 0 0 1 12SIab-On-Grade Edge Insulatio bdrm 4 11.5 ft 0 166.1 ftz �_ 0 0 1 13SIab-On-Grade Edge Insulatio bath 3 15 ft 0 54 ftz —__ 1 0 0 14SIab-On-Grade Edge Insulatio kitchen 1 ft 0 125.6 ftZ �__ 1 0 0 15SIab-On-Grade Edge Insulatio nook 19.9 ft 0 199.5 ft2 ____ 0 0 1 16SIab-On-Grade Edge Insulatio family rm 9 R 0 393.3 ftZ �__ 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch �� # Type Materials Area Area Color Absor Tested Tested Insul. (deg) 1 Hip Composition shingles 2708 ftZ 0 ftZ Medium 0.85 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2421 ftZ N N 1/3/2017 6:35 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Sofiware Page 3 of 6 � , FOFtM R405-2014 CEILING # Ceiling Type Space R-Value � Area Framing Frac Truss Type 1 Cathedral/Single Assembly(Vented}�aster bdrm 30 278 ftZ 0.1 Wood 2 Under Attic(Vented) o wic 30 57 ftz 0.1 Wood 3 UnderAttic(Vented) privy 30 19 ftz 0.1 Wood 4 UnderAttic(Vented) o bath 30 122 ftZ 0.1 Wood 5 Under Attic(Vented) dining rm 30 325 ftZ 0 1 Wood 6 CathedraUSingle Assembly(Vented) foyer 30 49 ft2 0.1 Wood • 7 CathedraVSingle Assembly(Vented) living rm 30 193 ft2 0.1 Wood 8 Under Attic(Vented) laundry 30 77 ft2 0.1 Wood 9 Under Attic(Vented) bdrm 2 30 154 ftZ 0.1 Wood 10 Under Attic(Vented) bath 2 30 47 ft� 0.1 Wood 11 UnderAttic(Vented) bdrm 3 30 161 ftz 0 1 Wood 12 Under Attic(Vented) bdrm 4 30 166 ft2 0 1 Wood 13 Under Attic(Vented) bath 3 30 54 ft� 0.1 Wood 14 Under Attic(Vented) kitchen 30 126 ftZ 0.1 Wood 15 UnderAttic(Vented) nook 30 200 ftZ 0 1 Wood 16 UnderAttic(Vented) family rm 30 393 ft2 0.1 Wood WALLS Adjacent S ace Cavity Width Height Sheathing Framing Solar Belo w P - � 1 E=>NE Exterior Concrete Block-Ext Insmiaster bdrm 4 14 6 10 0 145.0 ftZ 0 0 0.6 0 2 S=>SE Exterior Concrete Block-Ext Insmiaster bdrm 4 18 6 10 0 185.0 ft2 0 0 0.6 0 3 W=>SW Exterior Concrete Block-Ext Insor�aster bdrm 4 8 9 10 0 87.5 ftZ 0 0 0.6 0 4 E=>NE Exterior Concrete Block-Ext Insul o wic 4 9 6 9 4 88.7 ftz 0 0 0.6 0 _5 E=>NE Exterior Concrete Block-Ext insul privy 4 3 6 9 4 32.7 ft2 0 0 0.6 0 6 E=>NE Exterior Concrete Block-Ext Insul o bath 4 10 0 9 4 93.3 ftz 0 0 0.6 0 _7 N=>NW Garage Frame-Wood dining rm 11 6 6 11 4 73.7 ftZ 0 0.25 0.01 0 _ 8 N=>NW Exterior Concrete Block-Ext Insul foyer 4 7 0 9 7 67.1 ft2 0 0 0.6 0 _ 9 W=>SW Garage Frame-Wood foyer 11 6 9 9 7 64.7 ft2 0 0.25 0.01 0 _10 N=>NW Exterior Concrete Block-Ext Insulliving rm 4 15 0 10 0 150.0 ftz 0 0 0.6 0 _11 E=>NE Exterior Concrete Block-Ext Insulliving rm 4 16 6 10 0 165.0 ft2 0 0 0.6 0 _12 N=>NW Garage Frame-Wood laundry 11 7 0 9 4 65.3 ft2 0 0.25 0.01 0 _13 E=>NE Garage Frame-Wood laundry 11 1 0 9 4 9.3 ftZ 0 0.25 0.01 0 _14 N=>NW Garage Frame-Wood bdrm 2 11 27 6 9 4 256.7 ftZ 0 0.25 0.01 0 15 W=>SW Exterior Concrete Block-Ext Insul bdrm 2 4 11 0 9 4 102.7 ft2 0 0 0.6 0 16 W=>SW Exterior Concrete Block-Ext Insul bath 2 4 5 3 9 4 49.0 ftZ 0 0 0.6 0 17 W=>SW Exterior Concrete Block-Ext Insul bdrm 3 4 14 3 9 4 133.0 ftZ 0 0 0.6 0 18 W=>SW Exterior Concrete Block-Ext Insul bdrm 4 4 11 6 9 4 107.3 ftZ 0 0 0.6 0 19 S=>SE Exterior Concrete Block-Ext Insul bath 3 4 9 0 9 4 84.0 ft� 0 0 0.6 0 20 W=>SW Exterior Concrete Block-Ext Insul bath 3 4 6 0 9 4 56.0 ftZ 0 0 0.6 0 21 E=>NE Exterior Concrete Block-Ext Insul nook 4 4 9 11 4 53.6 ftZ 0 0 0.6 0 22 SE=>E Exterior Concrete Block-E�Insul nook 4 5 6 11 4 62.3 ft2 0 0 0.6 0 23 S=>SE Exterior Concrete Block-Ext Insul nook 4 9 9 11 4 110.5 ft2 0 0 0.6 D _24 S=>SE Exterior Concrete Block-Ext InsuFamily rm 4 9 0 11 4 102.0 ftZ 0 0 0.6 0 1/3/2017 6:35 AM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 4 of 6 FORM R405-2014 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NW Insulated foyer None .2 3 6 8 20 ftz 2 E=>NE Wood nook None .2 2 8 6 8 17.8 ftZ 3 N=>NW Wood laundry None .4 2 8 6 8 17.8 ftZ WINDOWS Orientation shown is the entered orientation(_> chan ed to Worst Case. / Wall Overhang \� # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 S=>SE 2 Metal Low-E Double Yes 0.54 0.31 32.0 ftz 1 ft 0 in 1 ft 7 in None None 2 E=>NE 6 Metal Low-E Double Yes 0.54 0.31 12.0 ftz 1 ft 0 in 1 ft 7 in None None 3 N=>NW 8 Metal Low-E Double Yes 0.56 0.28 4.0 ftZ 6 ft 0 in 0 ft 4 in None None 4 N=>NW 10 Metal Low-E Double Yes 0.56 0.28 22.7 ftZ 6 ft 0 in 0 ft 4 in None None 5 E=>NE 11 Metal Low-E Double Yes 0.54 0.31 16.0 ftz 1 ft 0 in 1 ft 7 in None None 6 W=>SW 15 Metal Low-E Double Yes 0.54 0.31 16.0 ftz 1 ft 0 in 1 ft 7 in None None 7 W=>SW 17 Metal Low-E Double Yes 0.54 0.31 16.0 ftz 1 ft 0 in 1 ft 7 in None None 8 W=>SW 18 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 1 ft 0 in 1 ft 7 in None None 9 SE=>E 22 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 8 ft 0 in 0 ft 4 in None None 10 S=>SE 23 Metal Low-E Double Yes 0.54 0.31 16.0 ftZ 1 ft 0 in 1 ft 7 in None None 11 S=>SE 24 Metal Low-E Double Yes 0.58 0.32 64.0 ftz 9 ft 0 in 0 ft 4 in None None GARAGE # FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 574 ftZ 384 ftz 61.5 ft 9.3 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000299 1697.3 104.16 195.88 .2241 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.7 32.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:15.2 34.8 kBtu/hr cfm 0.85 1 sys#1 1/3/2017 835 AM EnergyGauge�USA-FlaRes2014 Section R405 4 1 Compliant Software Page 5 of 6 FORM R405-2014 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS / —Supply— ---Return— Air CFM 25 CFM25 HVAC# \� # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 483 ftZ dining rm 453 ftZ Prop.Leak Free laundry —cfm 72.6 cfm 0.03 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb Mar A r Ma X Jun Jul Au Se Oct [ ]Nov Dec Heatin9 f X�Jan f X�Feb f X�Mar f �APr f �May 4 �Jun ��Jul ��Au9 ��SeP f �Oct [X]Nov f X�Dec Ventin [ Jan [ Feb [X Mar [X A r [ Ma [ Jun Jul Au Se [X Oct [X]Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 S 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 BO 80 PM 80 80 78 76 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 76 78 78 78 78 78 78 PM 78 78 78 78 78 76 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 � 1/3/2017 8:35 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 , , �FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerFormance Index, the more efficient the home. , , FL, 1. New construction or existing New(From Pians) 9. Wall Types Insulation Area - 2. Single family or multiple family . Single-family a.Concrete Block-Ext Insul,Exterior R=4.0 1874.90 ftZ b.Frame-Wood,Adjacent R=11.0 469.69 ft 3. Number of units,if multiple family 1 c.N/A R= ftz 4 Number of Bedrooms 4 d.N/A R= ftZ 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area 2 a.Under Attic(Vented) R=30.0 1901.00 ft 6. Conditioned floor area(ftZ) 2421 b.CathedraUSingle Assembly(Vented) R=30.0 520.00 ft2 7 Windows"` Description Area c.N/A R= ftzZ a. U-Factor Dbl,U=0.54 140.00 ftz 11 Ducts R ft a.Sup:Attic,Ret:dining rm,AH:laundry 6 483 SHGC• SHGC=0.31 , b. U-Factor Dbl,U=0.58 64.00 ftz SHGC� SHGC=0.32 12.Cooling systems kBtu/hr Efficiency c. U-Factor Dbl,U=0.56 26.67 ftZ a.Central Unit 34.8 SEER:15.20 SHGC� SHGC=0.28 d. U-Factor• N/A ftZ 13.Heating systems kBtu/hr Efficiency SHGC• a.Electric Heat Pump 32.8 HSPF:8.70 Area Weighted Average Overhang Depth: 4.283 ft. Area Weighted Average SHGC: 0.309 8. Floor Types Insulation Area 14 Hot water systems Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 2420.20 ft2 a.Electric EF 0.95 b.N/A R= ftz c.N/A R= {�= b. Conservation features None 15 Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building fi�E S�^ Construction through the above energy saving features which will be installed (or exceeded) ,4,�� `��'�Q in this home before final inspection. Otherwise, a new EPL Display Card will be completed ��",f,j''-�3' ^�����'�`�, based on installed Code compliant feat es. � +rr„��-��;:�-;�:;:� ,.u,s, o � _;�ti�:. ': .::. C! Builder Signature: Date: ° c� ":,u;�` � � Address of New Home: 6592 Paden Wheel Street City/FL Zip: Zephryhills, FL 3354 �t,�,: -�. r ��. � . co�w,�,�� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient , mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. ' 1!3/2017 8:37 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4 1 Compliant Software Page 1 of 1 ' Buildin Anal sis Job: 2421 sf g Y Date: 7/3/2017 Entire House By: DaveAldrich Bayonet Plumbing Heating and Cooling 8950 New York Ave,Hudson � . ' e . For: Lennar Homes � - • e • • Location: Indoor: Heating Cooling Tampa InternationalAP, FL, US Indoor temperature(°F) 70 75 _ Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight , Wind speed(mph) 15.0 7.5 Fireplaces 0 • I Component Btuh/ftz Btuh % of load Walls 5.6 9016 26.0 Glazing 30.2 6822 19.7 Doors 23.5 867 2.5 Ceilings � 1.3 3037 8.8 Floors 3.0 7334 21.2 Infiltration 2.1 3943 11.4 D ucts 3596 10.4 Piping 0 0 �' Humidification 0 0 � Ventilation 0 0 Adjustments 0 �' "' Total 34613 100.0 • s . Component Btuh/ftZ Btuh % of load Walls 2.8 4485 16.5 �' Glazing 40.6 9171 33.8 Doors 18.4 679 2.5 Ceilings 17 4199 15.5 Floors 0 0 0 /� Infiltration 0.4 820 3.0 D ucts 4032 14.9 Ventilation 0 0 „�„„ Internal gains 3750 13.8 Blower 0 0 ���""° Adjustments 0 �, Total 27136 100.0 � Latent Cooling Load= 3433 Btuh Overall U-value= 0.103 Btuh/ftz-°F Data entries checked. .` wri htsoft" 2017-Jan-03 08:46:20 ,�,.., 9 Right-Suite�Universal 2013 13.0.09 RSU05714 Page 1 �� H:\LENNAR LOADS\2421 sf ADS drawn.rup Calc=MJ8 Front Doo�faces• W • , ' Pro ect Summa Job: 2421 sf � J � Date: 7/3/2017 Entire House By: DaveAldrich Bayonet Plumbing Heating and Cooling 8950 New York Ave,Hudson � • ' • i For: Lennar Homes Notes: ADS specs i - • • • Weather: Tampa InternationalAP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 39 °F Design TD 16 °F Daily range , L Relative humidity 50 % Moisture difference 55 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 31017 Btuh Structure 23103 Btuh Ducts 3596 Btuh Ducts 4032 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 34613 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 27136 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2700 Btuh Ducts 732 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area(ftZ) 2421 2421 Equipment latent load 3433 Btuh Volume(ft') 24945 24945 Air chan es/hour 0.22 0.11 E ui ment total load 30568 Btuh i 9 q P E uiv.AVF cfm 91 46 Re . total ca acit at 0.85 SHR 2.7 ton q ( ) q P Y Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-036-230-18 Cond 14HPX-036-230-18 AHRI ref 5187082 Coil CBX27UH-036-230*++TDR AHRI ref 5187082 Efficiency 8.7 HSPF Efficiency 12_5 EER, 15.2 SEER Heating input Sensible cooling 29580 Btuh Heating output 32800 Btuh @ 47°F Latent cooling 5220 Btuh Temperature rise 25 °F Total cooling 34800 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.89 ' Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 1 _�.{_ WI'1 htsoft'° 2017-Jan-03 08:46:20 � 'I"" g Right-Suite�Universal 2013 13.0.09 RSU05714 Page 1 H:ILENNAR LOADS\2421 sf ADS drawn.rup Calc=MJB Front Door faces: W � r ` Manual S Compliance Report Job: 2421 sf Date: 1/3/2017 Entire House By: DaveAldrich Bayonet Plumbing Heating and Cooling 8950 New Yark Ave,Hudson � • ' • � For Lennar Homes • • . . . Design Conditions I Outdoor design DB: 91.3°F Sensible gain: 27136 Btuh Entering coil DB 75.7°F Outdoor design WB• 77 3°F Latent gain: 3433 Btuh Entering coil WB 62.8°F Indoor design DB: 75.0°F Total gain: 30568 Btuh Indoor RH: 50% Estimated airflow� 1200 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer� Lennox Model: 14HPX-036-230-18+CBX27UH-036-230`++TDR Actual airflow• 1200 cfm Sensible capacity: 29580 Btuh 109% of load Latent capacity: 5220 Btuh 152% of load Total capacity� 34800 Btuh 114% of load SHR. 85% e • • Design Conditions Outdoor design DB. 30.8°F Heat loss: 34613 Btuh Entering coil DB 69.6°F Indoor design DB. 70.0°F Manufacturer's Performance Data atActual Design Conditions Equipment type: SpIitASHP Manufacturer� Lennox Model: 14HPX-036-230-18+CBX27UH-036-230"++TDR Actual airflow: 1200 cfm Output capacity: 32800 Btuh 95% of load Capacity balance: 39 °F Supplemental heat required: 1813 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer� n/a Model: n/a+n/a Actual airffow: 1200 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 °F The above equipment was selected in accordance with ACCA Manual S. .�, �{:�}. wri htsoft" 2017-Jen-03 08:46:20 �, '�°' 9 Right-Suite�Universal 2013 13.0.09 RSU05714 Page 1 �C'p` H:ILENNAR LOADS\2421 sf ADS drawn.rup Calc=MJB Front Door faces: W Lennox Merit 14HPX-036-230 - 3 Ton, Up to 16.2 SEER/9.2 HSPF, 208 /230 Volt, Sin... Page 1 of 6 . H�/AC .com Heat•Air•Experts who care Contractoo- Directory Guides Pros Search our resource library..Q FAQs Blog Videos Learn Products More ���,e� i Lennox Merit 14HPX-036-230 - 3 Ton, Up to 16.2 SEER/ 9.2 HSPF, 208 / 230 Volt, Single Phase, R4. �A Heat Pump �� LENNOX MERIT 14HPX- f 036-230 - 3 TO N, U P TO � � 1�;,,� �, 16.2SEER / 9.2 HSPF, ' 208 / 230 VOLT, SINGLE �� " � P H AS E, R410A H EAT -,-w.— • r, PUMP �'- � r The Lennox Merit 14HPX-036-230 - 3 I � Ton, Up to 16.2 SEER/ HSPF 9.2, 208 / 230 Volt, 1 Ph, R410A Heat Pump. This product is a brand new genuine Lennox Heat Pump. - Get Installation or Repair Help > Download HVAC Maintenance Checklist > Product Details - .__. � _�.._,..�_ �_:- -..-_=.s__....._---.--..���.�t�__�__._�._.�.�s._. -�--_.___��_�.�.- w-:,-- -----_-____..__ �.-_-------__=a-___�-=_.___._ Lennox Merit 14HPX-036-230-3 Ton, Up to 16.2 SEER/ HSPF 9.2, 208/230 O Volt, 1Ph, R410A Heat Pump x https://www.hvac.com/shop/lennox-merit-14hpx-036-230-3-ton-up-to-16-20-seer-heat-pump 10/4/2017 SKETCH ONLY SEC. 05 , TWP. 26 S, RNG. 21 E. PLO`i"PLAN NOT A BOUNDARY SURVEY LOT 8, BLOCK 3 � BEARING BASIS: SILVERADO RANCH SUBDIVISION NORiH BOUNDARY OF SE� OF 05-26-21 BEING N 89'25'01" E PHASES Z, 7J 8C 4- ' THIS SURVEY IS SUBJECT TO ANY FACTS THAT PASCO COUNTY, FLORIDA. � MAY BE DISCLOSED BY A FULL AND ACCURATE 71TLE SEARCH. AL50 SUBJECT TO SETBACKS, PRELIMlNARYDRA1fVI1VG: OiV LOTAREACALCULATIONS EASEMENTS AND RESlRICl10NS OF RECORD. THIS PLAN IS FOR PERMITTING PURPOSES LOT — 9956.43 gQ, �, M UNDERGROUND FOOTER, STEM WALL, AND I ONI.Y, NOT FOR CONSTRUC110N. VERIFY LIVING AREA = 242� SQ. FT. �� UNDERGROUND UTILITIES ARE NOT LOCATED OR ALL DIMENSIONS BEFORE ANY CONSTRUCiION. EN7RY = �32 SQ. FT. SHOWN. GARAGE = 5�4 SQ. FT. LEGEidD: COVERED LANAI = 108 SQ. FT. w DO NOT SCALE THIS PRINT. DIMENSIDNS AND f-�= PROPOSED DRAINAGE FLOW PATIO =�A SQ. FT. Q NOTES TAKE PREFERENCE. (00.00) = PROPOSED GRADE CONC. DRIVE = 550 gQ, �. � E-00.00 = EXISTING GRADE A/C & CONC PAD = 9 SQ. FT. DESCRIPl10N NOT CONTAINING PLAT BOOK AND PRIVATE SIDEWALK = 57 SQ. FT. PAGE INDICATES THAT PLAT IS IN IMPERVIOUS = 39 y, PRELIMINARY STAGE AND IS SUBJECT TO — 3851 gQ, �, CHANGE AND/OR REVISION. SOD = 6105 SQ. FT. CERTAIN DATA SHOWN HEREON BASED ON �P��P� ENGINEERING PLANS PROVIDED BY CLIENT. OF'F LOT AREA CAI..CULA'FIOMS RIGHT OF WAY = �958-42 SQ. FT. STRUCIURE TIES SHOWN HEREON DENOTES DRIVE APRON = 350 SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION ,, PUBIJC SIDEWALK = 533 gQ. �. TO PROPERTY LINE. SOD = 1075 SQ. FT. * = 70' UTILITY EASEMENT TOTAI.S �' AREA = 11914.85 SQ. �. '�?:I DRIVEWAY = 900 SQ. Ff. SIDEWALK = 590 SQ. FT. SOD = 7180 SQ. FT. ^..�I U LOT 7 BLOCK 3 I I : oo, I `o •l �—/- ?. `0 6�J �_f. N 86'22'23" E 118.14' �- ' o.00' o' -- . -' �' 30 4� � N _ �I{'se, =w Q Q LOT 3 'i,9• :o £ n W BLOCK 3 f . N 69q3�, �1 � ' Zo150, n � ? :A G)N O N � � Q ' ' ' y -0 O� 6� � � :'A-�.r1,:.�.,,�. � � , N , o y O � • A �� � m �,. � '.''�o•*�..1.;.��'�c,'. n� �"�,� '" Ui L�j .,^ • � „ F •t.. �(p �L f � :r� �_�• :'2107- w '� :v c., N� ...����' , .� . :'.,.. �Y_2 3p59�.. - �s . ��.� . ::1 . � �. O i.'...2�1k. . -- (7pg3p) ��,1 0 .� �, \ ���- �� - \ � � �Z9 g5 GJ�k � \ a� � � 11$ \ � � •N�. ��o Z,Z � � � \� � S 6 � � � LOT 9 � BLOCK 3 � . (ra8os� IdOTES: I `O '�pp LOT GRADING IYPE = A � ,. �� PROPOSED PAD ELEVATION = 109.3' N DIESCRIPTIOI�� }'.\ FRONT SEf BACK = 20' N ' \ SIDE SET BACK = 7.5' � LOT 8, BLOCK 3, MAP :'�.'. REAR SETBACK = 15' 3 OR PLAT ENTITLED • � � "SILVERADO RANCH .•.\ PROPOSED: ; SUBDIVISION PHASES 2, �° LOWEST FLOOR ELEVATIONS: � 3 & 4", AS RECORDED LIVING AREA: 110.00' m IN PLAT BOOK 73, GARAGE AREA: � PAGES 59 THROUGM 65, ELEVATIONS REFERENCED TO ;' OF THE PUBLIC NORTH AMERICAN VERTICAL c� CURVE RADIUS ARC CHORD BEARING DELTA � RECORDS OF PASCO co Z�zaa• Zn.sz� 212.25' N 19'15•oz� e as•os•ie- DATUM OF 1988. MEAN SEA � COUNTY, FLORIDA. ciso z�zao' 105.36' 704J4• N ia7o�so� w zra�•aa•� LEVEL= 00.00 FT. _ U z APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL N0. 120230 0455 D EFFECTIVE DATE: 09/30/1992 � � __o LEGEND: - - � (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, r�= CENTERLfNE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= � CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN IJNK FENCE, CONC= CONCREIE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, N F/C= FENCE CORNER, FCM= FOUND CONCREIE MONUMENT, FlP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED / PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFlCIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONIROL POINT, PRM= PERMANENT o REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, iBM= TEMPORARY BENCHMARK, � U P= U1ILITY POLE W F= WOOD FENCE, R = RADIAL Drawn By. S uare Feet: 9956.43 t LENNAR HOMES � JOHN R.BEACi-I&ASSOCIATES,IWC. SMs 9 � SURVEYORS AND MAPPERS > 911 WEST ST. PETERSBURG DRIVE Checked By. in ONE OLDSMAR, FLORIDA 34677 �RB � y WAY (g73) 854-1276 FAX (813) 855-8370 Scale: ��=30' c I�y�p y� � Q� F`O W� •� NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 12 28 16 ACS 'v THE ORIGINAL RAISED SEAL OF A FLORIDA JOH . BEACH ATE � LICENSED SURVEYOR AND MAPPER F RIDA G. LAND SURVEYOR No. 2984 B#4493 � / Revisions: �