HomeMy WebLinkAbout17-18368 CITY OF ZEPHYRHILLS ,�
i 5335-8TH STREET
� '' (813)780-0020 18368 r
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION LOCATION INFORMATION
Permit#:18368 Issued: 4/20/2017 Address: 36137 STABLE WILK AVE
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: ' � Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 240,687.80 Total Fees: 11,277.69 Subdivision: SILVERADO
Amount Paid: 11,277.69 Date Paid: 4/20/2017 Parcel Number: 04-26-21-0070-00100-0250
CONTRACTOR INFORMATION OWNER INFORMATION
Name: D R HORTON INC Name: D R HORTON INC
Addr: 12602 TELECOM DR Address: 12602 TELECOM DR
TAMPA, FL. 33637 TAMPA, FL. 33637
Phone: Lic: Phone: 813-549-1968
Work Desc: CONSTRUCT NEW SINGLE FAMILY 2,362 SQ FT
APPLICATION FEES
B LDING FEE 1,009.21 ELECTRICAL FEE 204.98 PLUMB G FEE 136.65
MECHANICAL FEE 95.66 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00
SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
. � fi� ` �
�,��c��` �e[
' �'� c��''� � �/ _.
� � c��
' Ins ections Re uire �
FOOTER 2ND ROUGH P UMB MIS INS LATION CEIL NG
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTlON FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTlON FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this properly that
may be found in the public records of.this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an'attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall'be pertormed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
� �4-�J�o
CONTRACTORS SIGNATURE PERMIT OFFI '
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
� ` CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
. ; i
l•-'�.•'.,
y�`� �� PASCO COUNTY
4� ��� BUILDING CONSTRUCTION SERVICES
j�� �:��t.
?��. �H 8731 Citizens Drive Date:9/25/2017
:�i���. ' !�7�� Suite230
.F� +1/.�'�
��,;,� �:;;:� New Port Richey, FL 34654
��'�'�.�.k3�� 727-847-8127
x�c 4��� E � ��t \1�/@� � '�:sF
Receipt#: 1707872
FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE
Impact Fee Residential Solid 24503100-329010 18.52 1286608 $18.52 $18.52 1707872 9/25/17
Waste Single Family
ZHILLS SOLID WASTE.
TOTALS: $18.52 $18.52
Receiat# Paid Bv Check# CC Auth# Cashier ID Workstation Receiat Date Amt Paid
, 1707872 Check 640352 640352 294 BCCCP38W 09/25/2017 $18.52
Total Payments: $18.52
Pa'L�� Address Phone
DR HORTON 36137 STABLE WILK AVE
ZHILLS FL
Comments�
SILVERADO SUB: ��Q2/„�
0426210070001000250 O`J��
36137 STABLE WILK AVE
� �-E- � �c ' �C'r(�
MyReports/reports//PRODUCTION/PASCO/ReceiptPOS_V4 rp1 9/25/2017 Page 1 of 1
Q� o
� p 6�itA1Qfl_._
� .�•.�'i=.�i""'F
_ "*"y�„�p
� :•��� ' ��... ~�� I�tr, ,
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner:
Date Received:
Site: � ��J � / ����'�
� � P �
Permit Type:
Approved w/no comments:❑ Approved w/the below comments: ❑ Denied w/the below comments: ❑
�
This comment sheet shall be kept with the permit and/or plans.
�
Kalvin Switzer—Plans Examiner Date Contractor and/or Homeowner
(Required when comments are present) �
�
�
I
, ; DR Horton-36137 Stable Witk Ave-2,362 sq ft
o umn
SQ.FEET PRICE
MA(N OR LIVtRlG: 2,362 $ 101.90
OTHER AREA t1NDER ROOF: - $ 88.40
OTHER: - $ -
VA�UATION $ 240,687.80
FEE SHEET $ 911.04
ADDRESB $ 4Q.00
DRIVEWAY $ 40.00
BUILDING: $ 1,009.22
ELEGTRICA�: $ 244.98
PLUMBING: $ 136.65
MEGHANICAL: $ 95.66
SUB-TOTAL $ 1,446.&0
TOTAt. $ 1,446.50
- SEINER: na
WATER: na
IRRlGA710N: $ -
TOTAL: $ -
WATER METER: na
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PlANS TOTAL: na
INSPECTION TOTAL:
PERMIT TQTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FlRE $ 273.40
5°/a $ 26.35
TOTAL: $ 553.38
SUB-TOTAL $ 1,999.85
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00
100.4°to $ 4,828.00
1.0% $ 48.28
" TOTAL: $ 4,876.28
T I F'S: $ 3,632.00
- 99°l0 $ 3,595.68
1°/a $ 36.32
TOTAL: $ 11,277.69
04-26-21-0070-00100-0250 � Pasco County Property Appraiser Page 1 of 1
�C `Oy �
Data Current as Of: Weekly Archive - Saturday, April 15, 2017
Parcel ID 04-26-21-0070-00100-0250 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
DUNE FL LAND I SUB LLC Ag Land $0 �
C/O HAWK MANAGEMENT CO LLC Land $27,966
2502 N ROCKY POINT DR STE 1050 Building $0
ROCKY POINT FL 33607-5995 Extra Features $0
Physical Address
36137 STABLE WILK AVE
ZEPHYRHILLS, FL 33541 7ust Value $27,966
Assessed (Non-School Amendment 1) $27,966
Legal Description (First 4�ines)
SILVERADO RANCH SUBDIVISION
PHASES 2, 3 &4 PB 73 PG 059 Taxable Value $27,966
BLOCK 1
LOT 25
7urisdiction
City of Zephyrhills
Land Detail (Card: 001 of 001)
Line 'Use Descriptiom}Zoning Units Type ,Price fCondition Value
1 0100 SFR i MPUD � 6,000.00 � _S�$4.4 10 00 $26,400
2 f 0100 SFR � MPUD 4,745.00 SF { $0.33 ; 1.00 $1,566
Additional Land Information
----,--_..�_____ �
Acres � 0.25 � Tax Area � 30SI FEMA __ f,Residential Codel SLVRCPI
� ; Code � � �
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
Extra Features (Card: 001 of 001)
Line ��_�Description � jYear (Units � �;Value
No Extra Features
Sales History- See All 5 sales
Previous Owner:
��r_____.�� __�
Month/Year Book/Page ^ _ jType_�_�_ i�',DOR Code �Conditio mount _
_09/2011 J L 8606 / 3376 (__ Warranty Deed '` 05 Vacant Multi-Parcel Sale
' 05/2010 8373 1912 �' Certificate of TitleTj� 12 � �Vacant $0
/
07/2005 6725 / 1059 ; Quit Claim Deed j � Va�cant-'� � � $0
http://search.pascopa.com/parcel.aspx?sec=04&twn=26&rng=21&sbb=0070&b1k=00100... 4/20/2017
eis-�eo-oo2o City�.of Zephyrhills Permit Application ' F,
' Building Department . ` , ,
, ;i
� ''� � 1 2
Date Received Phone Contact'for Permitting -� '�
�
Owner's Name � 1� � cy �-. � Owner Phone Number J���• � _�
. Owner's Address
�o`;�o�o��'C���� P"" �f �G-/rij/��3� � /Owner Phone Number �a. �
. �
Fee Simple Titleholder Name G.r�� 'L Owner Phone Number
7
� 1 � �,,.
:�
Fee Simple Titleholder Address
JOB ADDRESS l/�` _ � � �� !�' E I �'� LOT# ��
.,
SUBDIVISION ��l �•G�'� �� PARCEL ID# �� °'��"J�/` ��P��J����`���
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED �NEW CONSTR e ADD/ALT � SIGN Q � �s DEMOLISH
INSTALL REPAIR
PROPOSED USE �` SFR Q COMM 0 OTHER
TYPE OF CONSTRUCTION � BLOCK Q FRAME 0 STEEL Q , ��.
DESCRIPTION OF WORK r�� S��/�����m-7 �, �'es��c-/LC'G ��� bo�.'��'� '��40�"�
���� i
BUILDING SIZE S�FOOTAGE H�IGHT �
rTi�1TT�r T
OBUILDING $ �� �% �o� VALUATION OF TOTAL CONSTRUCTION �
't,
QELECTRICAL $ ���� AMP SERVICE � PROGRESS ENERGY '� � W.R.E.C.
�r
�PLUMBING $ ���
-�s��� ,.� I ���
MECH . '+ l�
0 ANICAL $ ��� VALUATION OF MECHANICAL INSTALLATION ��
� ''� �
OGAS � ROOFING Q SPECIALTY � OTHER ;j
S
FINISHED FLOOR ELEVATIONS �� �� FLOOD ZONE AREA �YES NO ?; �
-�1--4-H-�1--1--1-1--1--F-1-i-1-1--b-�1-�1-1-1--1-•i-1-�f-f--1--4-1--1-1--f-�f••1-1-�--1-1--1-i-1-•1--F-1--f�-1--{-�• • • • •'• •1• • • 1-1-�4-1--1-
SIGNATURE D � � COMPANY �� �h - �1 U.�d-C��-�► ��r-C
REGISTERED Y/ N FEE CURRE� Y+/N'_
Address ��6�0�7'C��Ca� ,�r' J is-� � License t� �T�JC-���0 � �
ELECTRICIAN COMPANY �� lY10��pn ��'��-Tr'!,C:.
' SIGNATURE �� REGISTERED Y/ N FEE CURRE� Y�%N _
Address I-�3 � 5 k� I��r ��?G� �- License# ��l 3�� d�
PLUMBER � � COMPANY 1.,��/'/'1 Cl'S'ta /1 �-��'-�S
�IGNATURE �� REGISTERED Y/ N FEE CURRE� Y N
•� ,. .
Address "�l y�p G�` GQO � �u i-,� LGL License# G�� t y2��.2
MECHANICAL �� COMPANY �I�O r�55 i ��e- (-1 i r�y s-I-�er►-� r
SIGNATURE REGISTERED Y/ N FEE CURRE� Y;�N
� Address 5�D`� a.s/�jc,Pf'f, �or.�-�JC/�,� License# V C.� �y,
�y ;� :
OTHER �� COMPANY I� 1 ��G-r'� ��Q-� 1 n �
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address !� `�I"� f �?�1' ,57�- /�,c,� � License!f � W;��� � �
� � t � i � t � � � � � � � � � � t � i � � � i � � � � � � � � � � � o � � � ii � � � t � � �i � � � � i � � ii :i� � ii � � i � � �
RESIDENTIAL Attach (2) Plot Plans; (2)sets of Building Plans; (1)set of Energy Forms;�R-O-W Permit for new construction,;i
Minimum ten (10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plahs yil/Sllt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects �
COMMERCIAL Attach (2)complete sets of Building Plans plus a_Life Safety Page; (1)set of Energy Forms. R-O-W Permit for;hewi construction.
Minimum ten (10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plahs yi�/Sllt Fence installed,
Sanitary Facllities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must mee�compliance
SIGN PERMIT Attach(2j sets of Englneered Plans, �
****PROPERTY SURVEY required for all NEW construction.
-i..l.�l-a--L-4-1--{-1.-1--1-{-.1-.I-1-.I..L�I--�-�1-4:�-1.�-��1--f-.1.-1-�a-1--1--�-1--I.a-1-1--4-1--f-�1--1-�1--�-1..�1-.�.-4�• • • • :; • i • • 1.-1-.F-1...1�
Directions:
Fill out application completely. � �
.. �.
Owner&Contractor sign back of application,notarized ' �� � ' ' . ��. 1
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
*'' Agent(for the contractor)or Ppwer of Attorney(for the owner)would be someone with notarized letter from owner authorizing�sarrie
OVER THE COUNTER PERMITTING (copy of contract required) "
I Reroofs if shingles Sewers Service.Upgrades A/C Fences(Plot/Survey/Footage) , , `,i �
Driveways-Not over Counter if on public roadways..needs ROW " . �t �
,., . ., . ;� , .
_ � � �4 .
i . � r��, ��i .S
ICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions"
hich may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrjctions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertal<e work, they may be required to be licensed.in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation '
under state law If ttie owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contr�ctor(s) sign
portions of the "contr`actor Block" of this application for which they will be responsible. If you, �s the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County. , , �
TRANSPORTATION;IMPACT/UTILITIES IMPACT AND RESOURCE.RECOVERY FEES: The undersigned understands
that Transportation Impact:Fees;and Recourse Recovery. Fees may apply to the construction of new buildings, change of
use in existing buildin�s; dr� expansion=of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended, :+The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco.County Water/Sewer Impact
fees are due,they must be paid�prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone ,
other than the "owner", I certify that I have obtained a copy of th�e above described document and promise in good faith to
deliver it to the "owner" prior to commencement. � I
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and thaf all work I
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to`issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, Counly:and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Departrr�ent of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
� Lands, 1Nater/Wastewater Treatment. -
- Southwe.st Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
�.
Watercqurses.
- Army Cq'rps of Engineers-Seawalls, Docks, Navigable Waterways.
� - Departr�ent of Health & Rehabilitative Sefvices/Environmental .Health Unit-Wells, Wastewater Treatment,
Septic l�anks.
- US Envlronmental Protection Agency-Asbestos abatement.
- Federal��Aviation Authority-Runways. ,
I understand that;;the':following restrictions apply to the use of fill: _
- Use of f'll is�not allowed in Flood Zone"V" unless ex ressly permitted.
I p
- If th� fi�l material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time�of permitting which is prepared by a professional engineer
licensed�tby the State of Florida. �
- If the fijj;.material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill m�terial is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
, acre whlch are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to��commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall �e construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provislons of the technical codes, nor shall issuance of a permit prevent the Building Oificial from thereafter
requiring a cbrrectio'� ofi errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the worl< auXjiorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspeh'ded or abandoned for a period of six (6) months after the time the work is commenced. An extension
may be request�d, In writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety (90) consecutive days,the job is considered abandoned.
�; '
' WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR I
PAYING TWICGjFQ� IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER'OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.'S. 1t17.0
OWNER OR AGENT � ����-��� CONTRACTOR
Subs ribed and sw4�� to4(or affirmed before me this Subsc bed and sworn to or affirmed)before me this
__1��by .l:r�.c—nr►-c'���utJ-,c7.,..� !� /� by �ec �nc �il ,cc_�r 1-.r� .. ,
Wh is/ar personally known�to me or has/have produced Who is/are personally known to me or has/have produced
�;i as identification. as identification.
. b;
�' Nota Public
� '' Notary Public ���� ' �Y
t
Commission No. i: Commission No. .
�
��
Name of Notary typed,pr�nted or stamped Name of Notary typed,printed or stamped
Y Pu Notary�Publlc State of Florida
;o.�p►��� o�Y°�e� Notary Public State of Florida
. Gail M Donahue ; . Gail M Donahue
� � My Commieaton PF 170472 y4�, � My Commission FF 170472
'°�oFF,� Expiree 11l18/2018 `OFR� �xpires 11l18/2018
.� `
i - - _ I .
. . i
i
� ': PASCO COUNTY,, FLORIDA
� Permit No. � 3�
, � Date Permitted ;�,_
Builder Name/Owner Name �� �j��� Control#
� County Parcel No. O�-2(�-Z/_b�7o ,.bd(Z96��2kSZ) SubDiv: � � d
Address/Location 3(� �3'7 �,� �,��k��
Classi�cation/Type of Use �n j �,,���
TRANSPORTATION IMPACT FEE , Rate: ' Sq Ft Unit: Z,�(� '�
. � Exempt [] Yes � No How Determined ',
� Impact Fee Amount $ v�, (0,32. Zone No. �
TAZ:
SCHOOL IMPACT FEE �-
Account (056) S(ngle-Family Detached House Amount $ g"7�, Zg3
(057) Mobile Home
(058) Other Residential .
� 123) Collection Fee
Exempt [� Yes � No � How Determined
PARKS AND RECREATION FEE �
Land Account Land Credit iLand Total
� �Recreation Account __ Recreation Credit � ;
Recreation Total �
� Zone TOTAL AMOUNT $ 6�-S�(, �
Exempt [] Yes � No How Determined • -
' LIBRARY FEE
� Land Apcount Land Credit Land Total '
Facility Account Facility Credit "
Facility Total i
Exeinpt � Yes � No How petermined __ Total Amount
' � RESOURCE FEE ERU
TOTALAMOUNT
Prepared By Checked By i. ,
NO CERTIFICATE OF OCCUPANCY WILL BE I�SUED OR FINAL INSPECTION �
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
� BEEN PAID AND �
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY i
Acknowledgement below does not imply acceptance of concurrence;but slmply recelpt of a copy of thls form, lacing
the buflding permit owner on noUce of this assessment and tha conditions of payment for same.
I i
DATE RECEIVED BY I I
RECEIPT NO. DATE __j gY
� .
I
,��- '��� J o i
U
• ' "�/. �
..t Oittll,�ii�-
:'a;iri-„�.
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS .
� �Contractor/Homeowner: l ) 1� `I�'1�1'T�'� ��C-�
Date Received: I — j���
Site: �J�GL� �'l�� � �`d��..
Permit Type: C�_.� � �`�� C�
Approved w/no comrnents:� Approved w/the below cornments: Denied w/the belaw comments: ❑
�-�� ����
''�.
�
This coznment sheet shal,� e kept with the permit and/or plans.
�^��"
Kalv' Swi z —Plans Examiner Date Contractor and/or Homeowner
(Required when comrnents are present)
Single Family Dw�lling
Plan Review Comments
1. F.F.E. shall be a minimum of$"above the road elevation and an engineered site plan.
2. Lots shall be graded to comply with R401,3 of the F.B.C.
3. Compaction test required if 24" or more of fill dirt is brought in at any one place.
4. Tie in survey required befare pouring cancrete.
5. Driveways require a R.O.W, use permit. A114 sides of driveway thru the sidewalk shall have
expansion material.
6. All setbacks shall be met.
7. All property markers shall be uncavered and marked at time af first inspection.
8. All A.D.A. requirexnents sha11 be met.
9. No electric,plumbing,mechanical, ar framing shall be covered without an inspection and
approval first.
10. All Garages shall comply with section R302,6 af the F.B.C. {Fire Separation}.
11. Appliances shall not be installed in a location where subject to mechanical damage unless
pratected by appraved barriers. M303.4 of the F.B.0
12. Water heaters shall comply with section P607.3 of the F.B.C.
13. Fa2zndatiort supports for A1C units shall be raised at least 3"above finished grade. M1308.1
14. Return air in all bedroams. F.B.C. M1620.4
15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C.
16. All glazing requirements are to be in accardance with R30$.4 af the F.B.C.
17. All means of egress are to be in accardance with R311 af the F.B.C.
18. "Green gypsum baard" shall not be used as a backer in shawers or tubs. R702.4.2 F.B.C.
I 9. Combinatian-type AFGI breakers are required at aII lacations requiring an AFCI type breaker.
20. Carbon monaxide alarms will be required in new cansh-uction that uses fossil-burning heating
or appliances or an attached garage. They shall be installed in accordance with the F.B.C.
21. All plurnbing,mechanical, and electrical shall be separate from unit to unit. This includes all
underground plumbing and e�ectric.
22. A112008 N.E.C. Codes will be enfarced.
23. Tamper-Reszstant Receptacles in accordance with 406.12 of#he 2408 N.E.0
22. In accordance with the Land Development Code, lots shall be sodded before final at least 10
feet around the sfiructure.
F.F.E.-Finished Flaor Elevatian
F.B.C- Florida Building Code 5�'Edition
R.O,W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008)
i
�
1
�
I
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Cali Elevati n D Builder Name: DRH Exprgss H mes /p
Street: �13�'s�b��� I��21�,�L Permit Office: (��6��iL{/�t,�l-�1
City,State,Zip: Zephyrhills,FL,Z`]��.'I Permit Number: `� �
Owner: �rJ � Jurisdiction: �!�(pdb
Design Location: FL,Tampa ���/ County:: Pasco(Florida Climate Zone 2)
�� ! �
1. New construction or existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ft2
b. Frame-Wood,Adjacent R=11.0 306.22 ftz
3. Number of units,if multiple family 1 c.N/A z -
R= ft
4. Number of Bedraoms 4 d.N/A R_ ft2
� 10.Ceiling Types (1828.0 sqft.) Insulation Area
5. Is this a worst case. No a.Under Attic(Vented) R=30.0 1828.00 ftz
6. Conditioned floor area above grade(ftz) 1828 b.N/A R= ftz
Conditioned floor area below grade(ft2) 0 c.N/A R= ftz
� 11. Ducts R ft2
7. Windows(166.5 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356
a. U-Factor: Dbl,U=0.34 126.50 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl, U=0.55 40.00 ftz 12•Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00
c. U-Factor: N/A ftz
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftz a.Electric Heat Pump 28.6 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 2.722 ft.
Area Weighted Average SHGC: 0.317 14.Hot water systems
a.Electric Cap:50 gallons
8. Floor Types (1828.0 sqft.) Insulation Area EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ftz b. Conservation features
b.N/A R= ftz None
c.N/A R= n2 15.Credits Pstat
Glass/Floor Area: 0.091
Total Proposed Modified Loads: 60.65 pASS
Total Baseline Loads: 61.25
I hereby certify that the plans and specifications covered by Review of the plans and ��TH�ST,�T�
this calculation are in compliance with the Florida Energy specifications covered by this �� ���f '' � � p
Code. calculation indicates compliance ,�w'�,,, `� �='',.� �
with the Florida Energy Code. ti rr,r,r�''�.�-:;,=�'�°':��`���„ O
PREPARED BY: 1.'N4_�.,�.�.. Before construction is completed � ; ` �
DATE: II-7-16 this building will be inspected for � "'1:���3 ,3�
f,s�:
compliance with Section 553.908 * �� n �
I hereby certify that this building, as designed, is in compliance Florida Statutes. ,� y,t
with the Florida Energy Code. GOD���
OWNER/AGEN . BUILDING OFFICIAL:
DATE: DATE: `�� '�
- Compliance requires certification by the air handler unit manufacturer that the air handler closure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage�n requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Gln for whole house.
11/7/2016 10:14 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Pertormance Method
Project Name: Cali Elevation D � Builder Name: DRH Express Homes
Street: �13�'��b I��` I k.�e.1�,1�L Permit Office:
City,State,Zip: Zephyrhills,FL��.'I Permit Number:
Owner: �5 �/ Jurisdiction:
Design Location: FL,Tampa 1�// County:: Pasco(Florida Climate Zone 2)
!� (
1. New construction or existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1404.00 ftz
b.Frame-Wood,Adjacent R=11.0 306.22 ftz
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 4 d.N/A R_ ftz
10.Ceiling Types (1828.0 sqft.) Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ftz
6. Conditioned floor area above grade(ft�) 1828 b.N/A R= ftz
Conditioned floor area below grade(ft�) 0 � c.N/A R= ftz
11. Ducts R ftz
7. Windows(166.5 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356
a. U-Factor: Dbl, U=0.34 126.50 ftz
SHGC: SHGC=0.31
b. U-Factor: Dbl, U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00
c. U-Factor: N/A ftz
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftz a. Electric Heat Pump 28.6 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 2.722 ft.
Area Weighted Average SHGC: 0.317 14.Hot water systems
a.Electric Cap:50 gallons
8. Floor Types (1828.0 sqft.) Insulation Area EF:0.950
a.Slab-On-Grade Edge Insulation , R=0.0 1528.00 ftz b. Conservation features
b.WA R= ftz None
c.N/A R= ftZ 15.Credits Pstat
Glass/Floor Area: 0.091
Total Proposed Modified Loads: 60.65 pASS
Total Baseline Loads: 61.25
I hereby certify that the plans and specifications covered by Review of the plans and 0�'�STAT�
this calculation are in compliance with the Florida Energy specifications covered by this -� �� p
Code. calculation indicates compliance ��i'�„��'`� =�`���.� �s
with the Florida Energy Code. ti rnJ,�:���-;';Y::�:�;•�;,`�p
PREPARED BY: �'M11�-�� Before construction is completed r� ''' "''-' �
DATE: II-7-IG this building will be inspected for � --=�-,�� - ,�
, compliance with Section 553.908 * ° �
I hereby certify that this building, as designed,is in compliance Florida Statutes. ,S
with the Florida Energy Code. �G'G�D ���
OWNER/AGEN . BUILDING OFFICIAL: ���� '
DATE: DATE: -��7- �
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming.duct leakage to outdoors,
� tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 G1n for whole house.
11/7/2016 10:14 AM EnergyGauge(�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4
:
;
FORM R405-2014
PROJECT �
Title: Cali Elevation D Bedrooms: 4 Address Type: Lot Information
Building Type: User Conditioned Area: 1828 Lot# 25/1
Owner• Total Stories: 1 Block/SubDivision: Silverado Ranch
#of Units: 1 Worst Case: No PlatBook:
Builder Name: DRH Express Homes Rotate Angle: 225 Street:
Permit Office: Cross Ventilation: County Pasco
Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: Garage R Face SW
CLIMATE
� IECC Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
� FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium
,BLOCKS
Number Name Area Volume
� 1 Blockl 1828 15848.8
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated
1 Main 1828 15848.8 Yes 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 198.6 ft 0 1828 ft2 ____ 0 0.25 0.75
, ROOF
� Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2044 ftz 0 ftz Dark 0.92 No 0.9 No 0 26.6
� ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1828 ftz Y N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 1828 ftz 0.11 Wood
� 11/7l2016 10:14 AM EnergyGaugeOO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 2 of 4
, 1 .
FORM R405-2014 -
WALLS
Adjacent � Space Cavity Width Height Sheathing Framing Solar Below
1 N=>SW Exterior Concrete Block-Int Insul Main 4.0999 19 S 8 164.7 ftz 0 0.6 0
2 W=>SE 6cterior Concrete Block-Int Insul Main 4.0999 43 8 8 S 378.4 ftz 0 0.6 0
3 S=>NE Exterior Concrete Block-Int Insul Main 4.0999 39 S 8 S 343.8 ftz 0 0.6 0
4 E=>NW Exterior Concrete Block-Int Insul Main 4.0999 59 8 8 8 517.1 ftz 0 0.6 0
_5 N=>SW Garage Frame-Wood Main 11 20 0 S 8 173.3 ftz 0.23 0.01 0
_ 6 W=>SE Garage Frame-Wood Main 11 15 4 8 8 132.9 ftz 0.23 0.01 0
DOORS
# Omt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>SW Insulated Main None .4 3 6 S 20 ftz
2 N=>SW Wood Main None .46 2 S 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation => chan ed to As Built rotated 225 de rees .
J Wall Overhang
# Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N=>SW 1 Vinyl Low-E Double Yes 0.34 0.31 31.0 ftz 1 ft 0 in 4 ft 1 in Drapes/blinds Exterior 5
2 N=>SW 1 Vinyl Low-E Double Yes 0.34 0.31 2.5 ftz 3 ft 8 in 0 ft 0 in Drapes/blinds Exterior 5
3 W=>SE 2 Vinyl Low-E Double Yes 0.34 0.31 15.5 ftz 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5
4 S=>NE 3 Vinyl Low-E Double Yes 0.34 0.31 62.0 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5
5 S=>NE 3 Metal Low-E Double Yes 0.55 0.34 40.0 ft2 8 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5
6 W=>SE 2 Vinyl Low-E Double Yes 0.34 0.31 15.5 ftz 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5
GARAGE
# FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 430.0128 ftz 430.0128 ft2 46.6 ft 8.67 ft 0
INFILTRATION
# Scope Method - SLA CFM 50 ELA EqLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000386 1849 101.51 190.9 .2892 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump None HSPF:8.2 28.6 kBtu/hr 1 sys#1
11/7/2016 10:14 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
,
� -
FORM R405-2014
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit None SEER:14 28.6 kBtu/hr 858 cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 50 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftZ
DUCTS
/ ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
U # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 356 ftz Main 40 ftz Proposed Qn Main ---cfm 109.7 cfm 0.06 0.60 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Coolin Jan r lFeb Mar A r Ma Jun Jul Au Se Oct Nov Dec
Heatin9 f X�Jan [X]Feb �Mar �APr f �MaY 4�Jun 4�Jul ��Au9 4�SeP E�Oct �Nov Dec
Ventin [ �Jan [ ]Feb Mar A r [ Ma � Jun [ Jul Au � Se [X]Oct Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 S 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM" 68 68 68 68 68 68 68 68 68 68 66 66
Heating(W EH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
11/7l2016 10:14 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 4 of 4 II
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
- DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index,the more efficient the home.
, Zephyrhills, FL,
1 New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ftz
b. Frame-Wood,Adjacent R=11.0 306.22 ftz
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedraoms 4 d.N/A R= ftz
10.Ceiling Types Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ftz
6. Conditioned floor area(ft2) 1828 b.N/A R= ft2
z
7. Windows" Description Area 11 cDucts R R ftz
a. U-Factor� Dbl,U=0.34 126.50 ft2 a.Sup:Attic, Ret:Main,AH:Main 6 356
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.55 40.00 ft2
SHGC: SHGC=0.34 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ftz a.Central Unit 28.6 SEER:14.00
SHGC•
d. U-Factor• N/A ftz 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 28.6 HSPF:8.20
Area Weighted Average Overhang Depth: 2.722 ft.
Area Weighted Average SHGC: 0.317
8. Floor Types Insulation Area 14 Hot water systems
z a.Electric Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ft EF:0.95
b.N/A R= ft2
c.N/A R= ftz b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building qgE S7�
Construction through the above energy saving features which will be installed (or exceeded) ,ti,pf _ '�rc�o
in this home before final inspection. Otherwise, a new EPL Display Card will be completed y�r�`,,,��'%' _�-�,..�.�,
based on installed Code compliant features. � rr:,,,,��r-.;;�;=:.°;.�°;;��"„'�a�
Builder Signature: Date: � �"_�'' �
* �;.[I m �
Address of New Home: � ity/FL Zip: �� �, g�
cflD WE T�O
�7/
"Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638=1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff..
*'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1 1/7/201 6 1 0:14 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
�FORM R405-2014
Florida Department of Business and Professional Regulations
Residential Whole Buildin Performance and Prescri tive Methods
ADDRESS: Permit Number:
Zephyrhills, FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
� 401.3 Energy Pertormance Level(EPL)display card(Mandatary). The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
[Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy pertormance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C.
� R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402.4 4.
Q R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4 1 1 and R402.4.1.2.The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
• R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in
accordance with the manufacturer's instructions and the criteria listed in Table 402.4 1 1,as applicable to the method of construction.
Where required by the code official,an approved third party shall inspect all components and verify compliance.
• R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air
changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an
approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures,
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures;
3. Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air.
O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer
Exception: Site-built windows,skylights and doors.
O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
� R403.1.1 Thermostat provision(Mandatary). At least one thermostat shall be provided for each separate heating and cooling system.
� R403.1.3 Heat pump supplementary heat(Mandatary). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
� R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance
with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction
or rough-in testing below.
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section
553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following:
1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All
register boots shall be taped or otherwise sealed during the test.
2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g. (25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be
taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm
(85 Umin)per 100 square feet(9.29 m2)of conditioned floor area.
Exceptions:
1 The total leakage test is not required for ducts and air handlers located entirely within the building envelope.
2. Duct testing is not mandatory for buildings complying by Section R405 of this code.
11l7/2016 10•14 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
� R403.2.3 Building Cavities(Mandatary). Building framing cavities shall not be used as ducts or plenums.
❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)
or below 55°F(13°C)shall be insulated to a minimum of R-3., �
R403.3.1 Protection of piping insulation.
� R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can turn off the hot-water circulating pump when the system is not in use.
� R403.4.3 Heat traps(Mandatary). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. Extemal heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3'/z inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
� R403.4.4 Water heater efficiencies(Mandatory).
0 R403.4.4.1 Storage water heater temperature contrals
. R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum
temperature setting range shall be from 100°F to 140°F(38°C to 60°C).
. R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)
of combustion types of service water heating systems to be turned off. ,
� R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
' Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1
. R403.4.4.2.7 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar pomestic Hot Water System and Component Test Protocol,Collectors in instailed solar water
heating systems should meet the following criteria.
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment.
� R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1 This code does not allow designer safety factors,provisions for future expansion or other factors
which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
• R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
11/7/2016 10:14 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3
i
' , .
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
� R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and
shall not be used for equipment sizing.Manufacture's expanded pertormance data shall be used to select cooling-only equipment.This
selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the
load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of
equipment may be sized in accordance with good design practice.
� R403.6.1.2 Heating equipment capacity
' R403.6.1.2.1 Heat pumps. Heat pumps sizing shail be based on the cooling requirements as calculated according to Section
R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
. R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.6.1.
' R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric bumers
shall not be less than the design load calculated in accordance with Section R403.6.1.
� R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
❑ R403.8 Snaw melt system contrals(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall
include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F.
❑ R403.9 Swimming poals,inground spas and portable spas(Mandatory). The energy requirements for residential pools and
inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy
requirements for portable spas shall be in accordance with ANSI/APSP-14
Q R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
� R403.9.1.1 Gas and oil-fired poal and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum
thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
, R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
O R403.9.2 Time switches. Time switches or other control method that can automatically tum off and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in
compliance with this equipment.
Exceptions:
• 1 Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or
at the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or
' solar energy source computed over an operating season.
❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be
high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps.
� R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
� R405.2 Pertormance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
O R405.2.1 Pertormance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or
concrete deck roofs do not have sufficent space, R-10 is allowed.
1 1/7/201 6 1 0:14 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4 1 Com Page 3 of 3
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Cali Elevation D Builder Name: DRH Express Homes
Street: Permit Office:
City,State,Zip: Zephyrhills, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL,Tampa
COMPONENT CRITERIA - CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
� Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attiC The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings,drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls�shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim 'oists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow Cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
s aces. �
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated,and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatfy to fit around wiring and plumbing in
exterior walls,or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
EleCtrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
11/7/2016 10:14 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
J
FORM R405-2014 Duct Leakage Test Report Performance Method
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Form R405 Duct Leakage Test Report
Performance Method
Project Name: Cali Elevation D Builder Name: DRH Express Homes
Street: Permit Office: "
City,State,Zip: Zephyrhills,FL, Permit Number:
Design Location: FL,Tampa Jurisdiction:
Duct Test Time: Post Constructian
Duct Leakage Test Results
CFM25 Duct Leakage Test Values
Line System Outside Duct Leakage
1 System 1 cfm25(Out)
2 System 2 cfm25(Out)
3 System 3 cfm25(Out)
4 System 4 cfm25(Out)
5 Total House Sum lines 1-4
Duct System
Leakage Divide by
(Total Conditioned Floor Area)
_ (Q�,Out)
I certify the tested duct leakage to outside, Qn, is Duct tightness shall be verified by �'��E��'9,�
not greater than the proposed duct leakage Qn O _ .�
specified on Form R405-2014. testing to Section 803 of the RESNET ,��'fr�,,,f� w���,,��,
Standards by an energy rater certified in �a ,,, _:�:'..';,�� t
Fr Ft7tr/>_ `•.. �:r3� .'.��° �e Q
accordance with Section 553.99, � ; . .,,�.� ._. �s
Florida Statutes. r� . :5;�= . �- o .
SIGNATURE: `� �';r� • '�'
�
PRINTED NAME: r��'v�y�����
DATE: BUILDING OFFICIAL:
DATE:
11/7/2016 10:15 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Compliant S Page 1 of 1
J �
Q���a�gs'���,4 Manual S Compliance Report Da e: Oct 10,zo,4
; .�.� �,,,;...{{{��.� Enfire House Bv�
4:V.µ,� �„ ,.
�•�� Progressive Air Systems
S'�rEms.�a
5907 Dasher ct,Port Richey,FI 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669
• • ' • �
For: DR HortoNExpress
, Lot 25 Blk 1 Silverado, Zephyrhills, FI
• � . • •
Design Conditions
Outdoor design DB: 91.2°F Sensible gain: 21821 Btuh Entering coil DB: 75.4°F
Outdoor design WB: 77.1 °F Latent gain: 2966 Btuh Entering coil WB: 62.7°F
Indoor design DB: 75.0°F Total gain: 24787 Btuh
Indoor RH: 50% Estimated airflow: 1000 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: CH14NA030"""A+FB4CNP030
Actual airflow: 1000 cfm
Sensible capacity: 23270 Btuh 107%of load
Latent capacity: 3914 Btuh 132%of load
Total capacity: 27184 Btuh 110%of load SHR: 86%
• � o
Design Conditions
Outdoor design DB: 40.0°F Heat loss: 21100 Btuh Entering coil DB: 69.8°F
Indoor design DB: 70.0°F
Manufacturer's Pertormance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: CH14NA030"`**A+FB4CNP030
Actual airflow: 1000 cfm
Output capacity: 25604 Btuh 121%of load Capacity balance: 38 °F
Supplemental heat required: 0 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 1000 cfm
Output capacity: 6.6 kW 107%of load Temp. rise: 20 °F
The above equipment was selected in accordance with ACCA Manual S.
.� wri htsofts 2016-Nov-0412:24:54
^, � 9 Right-Suite�Universal 2013 13.0.11 RSU18520 Page 1
� ...on\Wrightsoit Files\E�ress homes\Cali 4EBB.rup Calc=MJ8 House faces:SW
�
:J
QP�G�E�,V���� Load Short Form Da e: Oct 10,2014
�.N.
;�. Entire House Bv�
�-�:� Progressive Air Systems
S'��Mg.�•►
5907 Dasher ct,Port Richey,FI 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669
� � ' • • I
For: DR Horton/Express
Lot 25 Blk 1 Silverado, Zephyrhills, FI
� - • • •
Htg Clg Infiltration
Outside db(°F) 40 91 Method Simplified
Inside db(°F) 70 75 Construction quality Semi-tight
Design TD (°F) 30 16 Fireplaces 0
Daily range - L
Inside humidity (%) 50 50
Moisture difference(gr/Ib) _ 26 54
I HEATING EQUIPMENT COOLING EQUIPMENT
Make Carrier Make Carrier
Trade CARRIER Trade CARRIER
Model CH14NA030"*"`A Cond CH14NA030`*"'A
' AHRI ref 6804001 Coil FB4CNP030
AHRI ref 6804001
' Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER
Heating input Sensible cooling 22500 Btuh
Heating output 29600 Btuh @ 47°F Latent cooling 7500 Btuh
Tem erature rise 27 °F Total cooling 30000 Btuh
P
Actual air flow 1000 cfm Actual air flow 1000 cfm
Air flow factor 0.047 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.88
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ft2) (Btuh) (Btuh) (cfm) (cfm)
M bed 194 3196 3505 151 161
living room 270 2891 4027 137 185
kitchen/dining 349 4292 5695 203 261
bed3 155 1420 1079 67 49
bath2 55 604 278 29 13
bed2 168 3411 2869 162 131
wc 21 24 35 1 2
M bath 114 1276 652 60 30
M wic 66 77 112 4 5
laundry 39 45 668 2 31
bed4/den opt 169 1866 1320 88 60
A/C closet 19 181 114 9 5
foyer 200 1817 1468 86 67
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
.� wri I7tS0'�" 2076-Nov-0412:24:54
�� 9 Right-Suite�Universal 2013 13.0.11 RSU18520 Page 1
.on\Wrightsoft Files\Express homes\Cali 4EBB.rup Calc=MJ8 House faces:SW
I
J -
Entire House d 1820 21100 21821 1000 1000
Other equip loads 0 0
Equip. Qa 1.00 RSM 21821
Latent cooling 2966
TOTALS 1820 21100 24787 1000 1000
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
.� WPI �'1tSOft` 2016-Nov-0412:24:54
�� 9 Right-Suite�Universal 2013 13.0.11 RSU18520 Page 2
�� .on\Wrightsoft Files\E�ress homeslCali 4EBB.rup Calc=MJS House faces:SW
, �
FORM R405-2014
RES/DENT/AL ENERGY CONSERVATION CODE DOCUMENTAT/ON CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative(Performance)Mefhod
Applications for compliance with the 2074 Florida Building Code, Energy Conservation via the
residential Simulated Performance method shall include
❑ This checklist
❑ A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, e-ratio and the pass or fail status along with summary
areas and types of components, whether fhe home was simulated as a worst-case
orientation, name and version of fhe compliance software tool, name of individual
completing the compliance report(1 page)and an input summary checklist fhat can
be used for field verification(usually 4 pages/may be greafer).
- ❑ Energy Performance Level(EPL)Display Card(one page) ' �
❑ Mandatory Requirements(three pages) _
Required prior to CO for the Pertormance Method:
- ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report(usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage; fhen a completed
Form R405 Duct Leakage Test Report(usually one page)
EnergyGauge�-USRCZB v5.1
1 1/4/201 6 2:05:29 PM Page 1 of 1
I