HomeMy WebLinkAbout17-18388 CITY OF ZEPHYRHILLS
;. 5335-8TH STREET
` tsis}�so-oozo 'i 8388 ,
BUILDING PERMIT SINGLE FAMILY RESTDENTIAL. �
- PERMIT INFORMATION - LOCATION INFORMATION
Permit#:18388 Issued: 4/2Qi2017 Address: 36149 STABLE WILK AVE
Permit Type: NEW SINGL.E FAMILY DWELLING ZEPHYRHILLS, FL. �F�
Gtass of Work: 1Q1-NEW CQNST/SFR Township: Range: �
Proposed Use: NOT APPL(CABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Boak: Page:
Cost: 323,532.50 Total Fees: 11,651.19 Subdivision: SILVERADD
Amount Paid: 11,651.19 Date Paid: 4/20/2017 Parcel Number: 04-26-21-0070-00100-024Q
CC}NTRAGTCfR INFORNIATIQN 01NNER INFORNIATI{)N
Name: D R HORTON INC Name: D R HORTON INC
Addr: 126Q2 TE�ECOM DR Address: 2502 N RQCKY PO1NT DR STE 1050
TAMPA, FL. 33637 ROCKY POINT, FL. 33607-5995
Phone: Lic: Phone: 813-549-1968
Work Desc: CONSTRUCT NEW SINGLE FAMILY Hf3ME 3,175 SQ FT
APPLICATION FEES
BU DIN EE ,263. ELE f21C �FE 2B1A0 P�UM ING E 174.Od
MECHANIGAL FEE 121.80 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCH(JOL IMPACT FEE-sfr/100°to 4,828.Q0
$GHOO�IMPACI'FEE-Sfrl l°l0 4$.28 TRI�FFIC IMPACT FEE 99°10 3,595.6$ TRAFFIC IMPACT F'EE 1°l0 36.32
�� � �� ��"�
, � � �ac�^�` _ .�� �
s�'- �.� , ��
� ��;��� � Q�
�
" Ins ections Re uired �
F TER 2 D RO � PL MB � SU lON LIN
FQOTER BOND DUCTS INBULATED SEWER MISC.
ROUGH ELECTRIG LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATlON WALL MlSC.
DUCTS IIUSTAI[.ED WATER M(SC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME �AISG. ftA1SC.
REINSPECTION FEES: (c)With respect ta Reinspection fees will comply with Flarida Statute 553.80(2)(c)the
laca!government shail impase a fee of four times the amount of the fee imposed far the initiai inspection or
first reinspection,whichever is gr�ater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit,there may be additionaf restrictions applicable to this property that
may be found in the public records of this caunty, and there may be additianal permits required from other governmental
entities such as water management, state agencies or federal agencies.
"1Narning ta owner: Your failure ta record a notice af commencemertt may resu[t in yaur paying twice far
improvements to your property. If you intend to abtain financing, consult with your lender or an attorney
before record"mg your natice of commencement,"
Complete Plans, Specifcatians and Must Accompany Application.All work shall be pertormed in accardance
with City Codes and Ordinances. NO t?CCUPANCY BEFORE C.Q.
NO OCCUPANCY BEFORE C.O.
��-�' �`- ,
� r�
�
CONTRACTORS SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN fi MUNTHS 1NITHOUT APPROVED INSPECTIO
CALL FOR xNSPECTION - 8 HOUR NOTICE REQUIRED
PRC>TECT CARD FROM WEATHER
- iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii�iiiiiiiiiiiiiiiiiiiiii
; , .
� 2017059874
I •
� O�/-Z( -�1 "l�D�D�O�/��-OZS�
Permlt No. ParcellD No
NOTICE OF COMMENCEMENT
� Slate of �l0 r I A_ County of PQS L_J.J
THE UNDERSIGNED hereby gives notice that improvemenl will be made lo certaln real property,and in accordance wilh Chapter 713,Florida Stalules,
the(ollowing informalion is provided in this Notice of Commencement: ^ � rd_ /
1 Description of Property: Parcel Idenlific tlon No. G' J �/
� Street Address: �J W� � '� L
I 2. General Description of Improvement }�'Q�� �!flQ �e Q VI/1�� �� {��i(i P l�� Q
3. Owner Information or Lessee in(ormelion if lhe Lessee conlracled for lhe improvement:
��ld l'�o/1 �'n cJ
I Z�oOZ N�e.I���M �r ' �vLt.r4C� c����3� LL
Address (� City�— Slale
Inleresl In Properly: t�e Q ��lVl t�(�
IName of Fee Simple T(Iieholder:
I (If different from Owner listed above)
I
I Address � n, ���r� _ ��� Ciry Stale
� � Contraclor: �1'1 j��1
� �Z�O��ame�P�e�AM �r T(�IM�Q 33�i� � �C�
Address CI — � Slale Q � W Y
Coniractor's Telephone No. Z U W
5. Surety: N�� � Z � � � W �
Address City Stale � � � = Q N � a
� Amount of Bond: $ �/� Telephone No. � W � F-- w F" w
6. Lender /�,��- O � S z � cG �
i Name �- LL � 0 — Q
Address City State � _ � � � �
� Lender's Telephone No.. _ ~ } U U'"
I
H
o_. � Y
i 7 Persons within lhe Stale of Fiorida designated by lhe owner upon vfiori'm notices or olher documents may be served es provided by U = O () W ,
i Section 713.73(t)(a)(7).Florfda Stalutes: � /� �F-- � J Q _1
! le/QI/l�� ("](7�-P � � U m p � V
Name [� � w � z O J
���L6 ���e.«LVl �� —(�ULU�G� c ����' � � � � � 2 ¢ W
A dress q /, it�j �— State � 1.11 G � } p Z
Telephone Number of Designated Person: �l " �`��—�7��� �,, 0 � O � �
> f�- o f- z �n
8. In addilion lo himself,Ihe owner designates � � °t � � Q J W ¢
to receive a copy of ihe Llenor's Nolice as provided in Section 713.13(1)(b),Florida Statules. � � w �, z —�
Telephone Number of Person or Entity Designated by Owner• p� z �
� �
� (4� H � � � � m
! 9. Expiration date of Notice of Commencement(the expiration dale may not be betore the completion of conslructlon and final payment lo Ihe
conlractor,bul will be one year from the date of recording unless e differenl dale Is specified): ii} � �.
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT �� , �0
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN � �:f•
RESULT IN YOUR PAYING lWICE FOR IMPROVEMENTS TO YOUR PROPERTY A NOTICE OF COMMENCEMENT MUST BE �j o ��
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT � ' q. � �,
•.• • 6Si
Under penalty of,perjury,I declare lhat I have read lhe foregoing nolice of commencement and lhal lhe facts staled therein are true to lhe best �• ' ���.� o�o �6.
o(my knowledge and belief. � ap � �
� STATE OF FLORIDA � �� _ �- , �
j COUNTY OF PASCO � ,Q � �.y
j Signat re o(Owner or Lessee,or Owner's or Lessee's Aulhorized
Repf,:1856343 Rec: 10.00 Offlcer/ ector/Partner�nnanager � •
DS: 0.00 ITo 0.00 �/ �j�
04/20/2017 J. R , Dpty Clerk ��� ���f0�/'�� - 1�•� Nn(77�/I�it(� �� a - �
Signatory's Title/Office ]o,� � �
/���� � /�pL �e �
The(oregoing instrumenl was acknowledqed before me lhis�day of N(IP,/ ,20�by_ I�1�i G V� �TP� �Q✓��
1 .1 —r��
as �I� �PI��L I CCf�/ (type of aulhority,e.g.,oncer,trustee,attomey in facq for
i
� . . ' r (l TIl l�_ (name of party o�behalf of whom(n lrument was executed).
Personally Known�OR Produced Identification❑ Notary Signalur (,� ,!�, (�S�(//
Type of Identifica�ion Produced � � c
Name(Print) v
pqULR 5 0'NEI�,Ph D PiiSCO CLERK B COMPTROLLER
04/20/201 38 m 1 of 1 �D
, OR BK ��2� P� 668 � Qjy NO�ryPuDltcSteteotFiorlde
Michelle Moyes
� �an°'T Expl�ro 72/21/2020 057321
I '
iwpdata/bcs/nolicecommencement�c053048 ,
Q:�£:'�fJ o�
�»
�:cgx+�ue
� J ���?a�._"�.
f�*
. �+ .
.. � �
Clty of ZephyrhillS
BITILDING PLAN REVIEW C011�IMENTS
Contractor/Homeowner: � ��V��.�'�-�-'- �
I
Date Received. � "� � ��� �
s���: 3 �. � �' �5��.� � ���� ��
�- �� , I
Permit Type: `�i �-� �-- �� (
Approved w/no comrnents:❑ Approved w/the below comments: �j Denied w/the below comrnents: �
J�,�
� �
,�
This comment sheet shall be kept with the permit and/ar plans.
.�--�'�
��.���� � ��
Ka1v n ans Examiner Date Contractor and/or Homeowner
{Required when comrnents are present)
�
�
� -
04-26-21-0070-00100-0240 � Pasco County Property Appraiser Page 1 of 1
, ; �� -
Data Current as Of: Weekly Archive - Saturday, April 15, 2017
Parcel ID 04-26-21-0070-00100-0240 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
DUNE FL LAND I SUB LLC Ag Land $0
C/O HAWK MANAGEMENT CO LLC Land $26,984
2502 N ROCKY POINT DR STE 1050 Building $0 �
ROCKY POINT FL 33607-5995 Extra Features $0
Physical Address
36149 STABLE WILK AVE
ZEPHYRHILLS, FL 33541 Just Value $26,984
, Assessed (Non-School Amendment 1) $26,984
Legal Description (First 4�ines)
SILVERADO RANCH SUBDIVISION
PHASES 2, 3 &4 PB 73 PG 059 Taxable Value $26,984
BLOCK 1
LOT 24
7urisdiction
City of Zephyrhills
Land Detail (Card: 001 of 001)
—_T------r- ---�— --T----- —T----,--- ---
Line iUse (Description+Zoning Units �Type �Price__ iCondit�on iValue
1� 0100 SFR ^�' MPUD_ � 6000.00 � SF� �_ $4.40_� 1.00�i $26,400V
- -- ---�- ------�--- ----�-- - -i- , �--
2 + 0100 � SFR � MPUD � ,1,771.00 j SF ; $0.33 � 1.00 � $584
Additional Land Information
----_.____ _.__T�`____- - ._.�_���_�.I____________.. _------- ---
---- � - ---
Acres � 0.18 i Tax Area I 30SI , FEMA ' __ iResidential Code� SLVRCPI �
, � � Code ; � i
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
Extra Features (Card: 001 of 001)` ___
Line ---J�----Description� _1Y a � �_jUnits---- -----—jValue -__--_----� -- �
No Extra Features
Sales History - See All 5 sales
Previous Owner:
�_____^_ ..^.�----------- -
� � ------ -i ----�-_.—:�._--,_ —_---- -.__
Month/Year Book/Page _ __ ;Type _ __ __�_^�DOR Code �Condit�on _ }Amount
----_,__.�______ _._.__` ____
09/2011 i 8606 /_3376 __�_ Warranty_Deed_ f 05 _ � Vacant ; Multi-Parcel Sale
�_�...�___ _ _._
05/2010 j 8373 / 1912 � Certificate of Title � 12 ___I` VacantJ�_ �_ $0 _ Y__
07/2005 �6725 / 1059 ; Quit Claim Deed �� � vacant � $0
http://search.pascopa.com/parcel.aspx?sec=04&twn=26&rng=21&sbb=0070&b1k=00100... 4/20/2017
, Illllllllllllllillllllllllllllllllllllllllllllllllllllllilll
� 2017089573
Permit No. Parcel ID No DG/���r�/-�✓�Q�W/V(/-�Z�/lJ
� NOTICE OF COMMENCEMENT
I Stale of� r I �1 _ Counly of PQS l S..J
THE UNDERSIGNED hereby gives notice thal improvemenl will be made to certaln real property,and In accordance with Chapter 713,Florida Statutes,
the following informalion(s provided in this Nolice ot Commencemen� 9
1. Description of Property: Parcel Identification No. Q�� LG d�
Stree�Address: W I-I i/ J
2. General Descriplion of Improvement J� �
3. Owner Informalion or Lessee Informalion if lhe Lessee conlracted for the improvement:
T>. G�. o/+�n TnC�
�Z�o z "-�'�.►���n� �n� ��� ��� L—�
Address r City—� Slale
I Inlerest in Property: T C e ��l����
Name o(Fee Simple Tilieholder
(If different from Owner listed above)
R Address n r _ City Stale w Y
Comractor. �• V�- �I�7rY7Jn T/LP _ � r
f /l�O ame'.�e,I eCoM �r ��IM fDQ 33�3� �L � W I.L (n'_ W W
LC
Address CI Stale �(,� � O S J U
Conlractors 7elephone No. �Z U � F- O �
5. Surely: N���- ' �� � = W N � W
L6. w ~ (n d 0
, Address Cily State � �� Z Q �
Amount of Bond: $�[�/� Telephone No. �-�-. � LL. � U O
� _ � � � �S
6. Lender:
U
Name` o � � � � �
Address City Slate v S OD U z �
� J
i
Lendefs Telephone No. Q } � m Q U
� OJ
7. Persons wilhfn the Slale of Florida designaled by the ovmer upon whom nolices or olher documenls may be served as provided by Qe � � a Z
Seclion 713.13(1)(a)(7),Florida Stalules: _r /' Q >- �J
Nam6 �b Q I�I�CL l`�1��'� � LL�'1 Q � } p O
U U � �
��(o o `�'�1e�� �r �w�.�Oq, �3�����- � o 0 0 0 � �, �
A dress // i�
I Telephone Number of Designated Person: �3� �/(�—���Q Stale Q � � � � _
/7" ot E-- _ � Z Q �"
I 8. In addition to himself,Ihe owner designales ��Z� _ , � r � O � a m
to recelve a copy of lhe Lienor's Nofice as provided In Sectlon 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entily Designaled by Owner•
9. Expiration dale of Nolice of Commencemenl(the expiretion dale may not be before the completlon of construclion and final payment to Ihe �� � • � �
Iconlractor,bul wili be one year from(he tlate of recording unless a differenl date Is speclfied): �� o � �
� WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER 7HE EXPIRATION OF THE NOTICE OF COMMENCEMENT �� ��
� ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN �
RESULT IN YOUR PAYING 7WICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE �
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT o I�. �a � ,� �
I W1TH YOUR LENDER OR AN ATTORNEY BEPORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT � 1_,,,•� �' � � � 1
Under penalty of perjury,I declare thal I have read the foregoing notice of commencement and lhat lhe facls staled therein are true to the best � ' ����y. ',� d .�J
of my knowledge and belief. � � , �1
STATE OF FLORIDA � m ,' ��'
COUNIY OF PASCO ������ �� r �
Signat re o Owner or Lessee,or Owner's or Lessee's Authorized ;
I Repf.:1856643 R¢e: 10.00 Officed uectodPariner/Manager' _/ ��g� a ��
D5: 0.00 IT; 0.00 ��'� �P�fP�o/��/ — �•' (7Z LAc' �e`S° e �
I 04/20/2017 J. R., Dpty Clerk ��n � y�
i Signatory's Titie/Office
iThe toregoing(nstrument was acknowledged before me Ihis�day of�U�,20�by I�I�i G V� ��P(.�r
as���'� �Ol����/'�/ (type of aulhoriry,e.g.,offcer,truslee,attomey in facp for
i
�. . • r �l T/�C_ (name of part on behai(of hom instrument was execuled).
I ,_./ Iy ��/
� Personally Known i.y OR Produced Idenlificalion❑ Nolary Signalu Gf/ ���'`�/[�(�
� ' '. //_
Type of Identification Produced Name(Prinl) V
PRULR S 0'NEIL,Ph.D PqSCO CLERK d COMPTROLLER
04/20/201 01:36 m 3 of ,,,cn° NOteryPublicSteteofFlorlde
OR BK 52� PG 66� � �' Mlchelle Moyes
`� My Commiaslon GG 057321
'•o�� Explres 12/272020
wpdala/bcs/nolicecomme n ceme nt�c053048
`: PASGQ GQUNTY, FLORIDA
.' . Permit No. Z�/v��`�`
Date i'ermitted �=2a L�'
, Builder Name/Owner Name �'�1�--�/U!'"���y+l'�i�-- Contro!#
"��� � �p
� County Parcel No.��-?.�-.2-j-(,X�'�p- C�l�Lt�r�.;(}2 Y�pBubDiv: ,�i U��R�17
AddresslLocation <�t�'� (�7`�f� /�r�j� �G,
ClassificationlType of Use ` j
: TRAN�PORTATION IMPACT FEE Rate: Sq Ft Unit: �y�__
Exempt [] Yes (� No How Determined
� Impact Fee Amount $�,�c3�. Zone No. TAZ:
SCNOQL lMPACT FEE
{ Account (056} Single-Family Detached House Amount $ ��'�{.2�
' (057) Mo6ile Name
(058} Qfher Residential �
123) Co!lection Fee '
Exempt [�Yes [] No How'Determined
i
� PARKS AND RECREATIQN FEE
' �and Account Land Credit Land Totai
� Recreatlon Account Recreation Credit Recreatian Total
i � '
, Zone •� TOTAL AM�UNT $ �/��,��;
i Exempt [] Yes [� No Now Determined �
LIBRARY FEE
Land Account Land Credit Land Tatai �
Facifity Account Facility Gredit Facility Totai
� Exempt ❑ Yes ❑ Na How Determined Total Amaunt`�---- .
RESOURGE FEE ERU
- TOTAL AMOUNI" � .
� Prepared By � Checked By
NO CERTtFICATE OF OCCUPANGY WILL BE ISSUEQ OR FlNAI.iNSPECl'!ON
PERFG?RMED UNTlL THE TO'fA�AMC)UNTS LtSTED HAVE
� BEEN PAID AND •
RECEIPTED FQR BY A CENTRAL PERMITTING OFFICE OF PASCO Ct3t7FtTY
' Acknowledgement below does not imply acceptance of cancurrence,but simpiy receipt of a copy of this form,plactng
tha butiding permEt owner on nofice of ihis assessment and tha conditions of payment for same.
DATE RECEiVED BY
RECEIPT NO. QATE BY
• ' DR Horton-36149 Stable Wilk Ave-3,175 sq ft
o umn
SQ. FEET PRICE
MAIN OR LIVING: 3,175 $ 101.90
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 323,532.50
FEE SHEET $ 1,160.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,263.20
ELECTRICAL: $ 261.00
PLUMBING: $ 174.00
MECHANICAL: $ 121.80
SUB-TOTAL $ 1,820.00
TOTAL $ 1,820.00
SEWER: na
WATER: na
IRRIGATION: $ -
, TOTAL: $ -
WATER METER: na
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: na
INSPECTION TOTAL:
PERMIT TOTAL �
TOTAL: $ -
+ PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
, SUB-TOTAL $ 2,373.35
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
�', TOTAL: $ 11,651.19
��
04-26-21-0070-00100-0240 � Pasco County Property Appraiser Page 1 of 1
Data Current as Of: Weekly Archive - Saturday, January 21, 2017
Parcel ID 04-26-21-0070-00100-0240 (Card: 001 of 001)
Classification 00 -Vacant Residential
Mailing Address Property Value
DUNE FL LAND I SUB LLC Ag Land $0
C/O HAWK MANAGEMENT CO LLC Land $26,984
2502 N ROCKY POINT DR STE 1050
ROCKY POINT FL 33607-5995 Building �p
Physical Address Extra Features �Q
36149 STABLE WILK AVE
ZEPHYRHILLS, FL 33541
Leqal Descrintion (First 4 Lines) 7ust Value $26,984
SILVERADO RANCH SUBDIVISION AssesSed (Non-School Amendment 1) $26,984
PHASES 2, 3 &4 PB 73 PG 059
' BLOCK 1
LOT 24 Taxable Value $26,984
Jurisdiction
Citv of Zeohvrhills
_ _ ,�Land Detail (Card: 001 of 001) _ _
r---- -- —
_ Line_�+_� Use Description� Zoning Units i Type �� Price �(Condition Value
- -- �.-- ;-- -
____1 I 0100 SFR � MPUD�6,000.00 �_ SF I $4.40 ' 1.00 $26,400
2 � ��0100 SFR� r MPUD � 1,771.00 { SF $0.33 , 1.00
- -- + $584
______ ___�_ __ Additional Land Information
Acres 0.18 � Tax Area 30SI � FEMA i _ � � �
�� � � Code E �Residential Code SLVRCPI
�
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
Extra Features (Card: 001 of 001)
- _._— --`_____ �e___.�----.----
- ---�--_-- ---___- T �.«-----�.��
__Line `_�_ Description I Year Units i Value
- ---- - __1—_— --------- ----
No Extra Features
Sales Historv-See All 5 sales
Previous Owner:
Month Year Book Pa e �� T �~
/ / g ype DOR Code ' Condition Amount
--�--- -�--.�
09/2011 8606 / 3376 � Warranty Deed 05 i Vacant Multi-Parcel Sale
- __--l___- -- --� .���- --�-------
05/2010 � 8373 / 1912 � ' f `-"
_,_ _ _ _� Certificate of Title � 12 i Vacant ; $0
----;__
� 07/2005 6725 / 1059 Quit Claim Deed � � Vacant � � $0 v
http://appraiser.pascogov.com/search/parcel.aspx?parce1=2126040070001000240 1/26/2017
e1s-�eo-oo20 � City�of Zephyrhills Permit Application Fax-ala-�ao=oozl
, ' Building Department ' _ , � •
• • �!
,, •
Date Received ' F '
Phone Contact'for Permitting -- ,
Owner's Name � � a ey � � Owner Phone Number ��'1�. � �.7�n O
�a�oa z����a ,-�-- n.� �T�.�.,��3� 3 s
Owner's Address �Owner Phohe Number
. �
. 9
Fee Simple Titleholder Name G.�ri � Owner Phone Number �s
, , ,
1 •
Fee Simple Titleholder Address
JOB ADDRES5 ���� � �Y" f �{{ �`� LOT N � f
,
SUBDIVISION S�1 � ��r'� �p PARCEL ID# � /'"�m�l��������������
(OBTAINED FROM PROFERTY TAX NOTICE) �
WORK PROPOSED �NEW CONSTR e ADD/ALT � SIGN 0 � '� DEMOLISH
INSTALL REPAIR ' n
PROPOSED USE �� SFR Q COMM 0 OTHER '
TYPE OF CONSTRUCTION � BLOCK Q FRAME � STEEL Q
DESCRIPTION OF WORK ��� S��/�j��7��-���, I�5���-/�C� �J�esQ ba-'�'� '����-`
�/J� l
BUILDING SIZE SO FOOTAGE H�IGHT
'QBUILDING $ � �� VALUATION OF TOTAL CONSTRUCTION 'Y
l�J/!� ,
.3
QELECTRICAL $ ��� AMP SERVICE � PROGRESS ENERGY .� �] W R.E.C.
�PLUMBING $ ���� �
;i
MECHANICAL ��
0 $ /��� VALUATION OF MECHANICAL INSTALLATION ��;;�
�J ;� ,
�GAS � ROOFING Q SPECIALTY � OTHER '�
FINISHED FLOOR.ELEVATIONS .�� - FLOOD ZONE AREA QYES NO :� �
r ,{
�f--f-1--f�-1--1--1-1-��F�-1-�F�1--f�1-1�1-�1�-f-L�1--1--F-1--F-1-1--i�1�-f-�f�l--1-f--1--F-1--F-1-4�-f�-1-f$■ • •. • • '' ''�' ` • 4�1-1-1--1�
BUILDER � ��
COMPANY � T - � � '�1� � C
SIGNATURE � � � �� �
REGISTERED Y/ N FEE CURRE� Y'/N
Address ����v?����Co/� /'r' I M C License t# �TJe-�3�� G� 2
ELECTRICIAN �`� COMPANY v�iti IY�On�an ��'e LT,r�� CG
SIGNATURE �'� REGISTERED Y/ N FEE CURRE� Y'%N r
Address / �� �' ,5�L� �Cr' �,�.�G��.. �- License# �'ci 3aes5 �� I
PLUMBER � � COMPANY d/"/'1 C/'S'7�0 /1 •���-�tS
SIGNATUHE �� REGISTERED Y/ N FEE CURRE� Y� N �
�'l y� G! c�o ,
Address � �v�-.� LGL License# G�� I y2�82
MECHANICAL �� COMPANY �1�0 r�5v� �� �-1 ir-�y s-�-cn-� 1'
SIGNATURE REGISTERED Y/ N FEE CURRE� Y;/N
Address 5�j0� c�s����'f, ��r..��l J`��,� License# V C�
OTHER ��-�.�� COMPANY � 1 �L Cr/'fS� �Qp�n ��
SIGNATURE REGISTERED Y/ N FEE CURRE� Y,- N ,
Address �.�'J"f� f �7'?f%' ,��-- ��,,c+-z �' License/# � C,,.t�,��,� � � !
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ,1` 1 1 1 1 1 1 1 1 1
RESIDENTIAL Attach (2) Plot Plans; (2)sets of Building Plans; (1)set of Energy Forms;�R-O-W Permit for new construction,�i,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans v�/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach (2)complete sets of Building Plans plus a Life Safety Page; (1)set of Energy Forms. R-O-W Permit fo�new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plahs yJ/Sllt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.Ail commercial requirements must mee�compliance
SIGN PERMIT Attach (2)sets of Engineered Plans. � ��
****PROPERTY SURVEY required for all NEW construction. '•
D�irecti~ns 1--1--�-1--I�i..1-.1..1...1--1--1_I-.1-.i_I-.��1--1--+_f-��.�-4�-1-.�..4-1--1_4-1--4.L-1--��1�-1--1_I--1-1._I--1..�• • • • :� • • • • 1.�..�_1--1...
!
Fill out application completely. � �
Owner&Contractor sign back of apPlication,notarized ' �! '� ' •�
If over$2500,a Notice of Comrrmencement is required. (A/C upgrades over$7500) �
** Ageht(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizin I'sarne
OVER THE COUNTER PERMITTING co g'
( py of contract required) �
Reroofs if shingles Sewers Service.Upgrades A/C Fences(Plot/Survey/Footage) , ,
c
Driveways-Not over Counter if on public roadways..needs ROW " . _-� � ��
� � , _ k -- .
, � , ��
, " . , ,. , , •i; t
. r, _ ,,
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restr�ctions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed.in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore,'if the owner has hired a contractor or contractors, he is advised to have the contr�ctor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not proper•ly licensed and is not entitled to permitting privileges in Pasco
" County.
TRANSPOFtTATIONiIMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, changE of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended, ��The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that t, the aPplicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the "owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and thaf all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County'and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Departrr�ent of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, WaterM/astewater Treatment. -
- Southw�st Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercqurses. �
- - Army Cp�ps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic l'anks. ,
- US Environmental Protection Agency-Asbestos abatement.
- Federal`Aviation Authority-Runways. ,
I understand that;the`.following restrictions apply to the use of fill:
- Use of fll is°not allowed in Flood Zone "V" unless expressly permitted.
- If the fill,` material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating.volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed�.;by the State of Florida. �
- If the fill;material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill•;m`te�ial is to be used in any. area, I certify that use of such fill will not adversely affect adjacent
�,
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
, acre whlch are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to;commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall �`e construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisibns of the technical codes, nor shall issuance of a permit prevent the Building Official frqm thereafter
requiring a correction ofi errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the worl< auxtiorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is susper�ded or abandoned for a period of six (6) months after the time the work is commenced. An extension
may be requested, In writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety (90) consecutive days,the job is considered abandoned.
�>,: �
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICEiFQR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSIDLT
WITH YOUR LENDER'OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S. iy-7.0
. �
OWNER OR AGENT, � I�� CONTRACTOR �
Subsc Ibe and swqL`(�tof(or sffirmed)before me this Subs ibe and sworn to or affirrr�ed)before me this
_�by .0�.'e—n n-c i3,r_�uC!-,c 1��c /fJ ,� by ��c�n e_�L �cy�r l-.r_�,� ,
W is/a e personally Icnown to me or has/have produced W o is/are personally known to me or has/have produced
=i as identification. as identification.
' � .
;;
' Notary Public � ' Notary Public
4
Commission No. + Commission No.
� i,� '
��
I°
Name of Notary typed,prjnted or stamped Name of Notary typed,printed or stamped
iysY k� Notary`„Public Stale of Florida o.aaY� Notary Public State of Florida
o°��; Geil M Donahue ; � Gail M Donahue
y �o� My Commieslon FF 170472 �oQ My Commission FF 170472
9jPOFF,d" Expirea 11/18I2018 �pFp,o`' Cxpires 11/18/2018
r
:1 ` '
Single Family Dwelling
Plan Review Comments
1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan.
2. Lots shall be graded to comply with R401.3 of the F.B.C.
3. Compaction test required if 24" or more of fill dirt is brought in at any one place.
4. Tie in survey required before pouring concrete.
5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have
expansion material.
6. All setbacks shall be met.
7. All property markers shall be uncovered and marked at time of first inspection.
8. All A.D.A. requirements shall be met.
9. No electric, plumbing,mechanical, or framing shall be covered without an inspection and
approval first.
10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).
11. Appliances shall not be installed in a location where subject to mechanical damage unless
protected by approved barriers. M303.4 of the F.B.0
12. Water heaters shall comply with section P607.3 of the F.B.C.
13. Foundation su orts for A/C units shall be raised at least 3" above finished rade. M1308.1
PP g
14. Return air in all bedrooms. F.B.C. M1620.4
15. Smoke detectors are to be installed in accordance with R313.1 o�the F.B.C.
16. All glazing requirements are to be in accordance with R308.4 of the F.B.C.
17. All means of egress are to be in accordance with R311 of the F.B.C. '
18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C.
19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker.
20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating
or appliances or an attached garage. They shall be installed in accordance with the F.B.C.
21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all �
underground plumbing and electric.
22. A112008 N.E.C. Codes will be enforced.
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0
22. In accordance with the Land Development Code, lots shall be sodded before final at least 10
feet around the structure.
F.F.E.-Finished Floor Elevation
F.B.C- Florida Building Code Sth Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2008)
36149 Stable Wilks Ave
o umn
SQ. FEET PRICE
UNDER ROOF: 3,175 $ 101.90
OTHER: - $ -
VALUATION $ 323,532.50
FEE SHEET $ 1,160.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,263.20
ELECTRICAL: $ 261.00
PLUMBING: $ 174.00
MECHANICAL: $ 121.80
SUB-TOTAL $ 1,820.00
TOTAL $ 1,820.00
SEWER: $
WATER: $
IRRIGATION: $ -
TOTAL: $ 2,651.
WATER METER: $
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $� 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 5,498.13
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 14,775.97
PLOT PLAN
DESCRIPTION:(AS FURNISHED)
' LOT 24, BLOCK 1, SILVERADO RANCH SUBDIVISION PHASE 2, 3 & 4
AS RECORDED IN PLAT BOOK 73, PAGE(S) 59-65, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA.
. 1
� ` LOT 25 �
Z � BLOCK 1
�" = 3�' � Ob 1 (NOT RAOIAL)
GRAPHIC SCALE I °j0 9� S88'�5'26"E a$`
o �5 so ,:.. 111.58'
i �a. w
� :r,; i �;� � � � _
� 3e t7 '.+�",'�.-',",. � Ir- -� — — — — — N — — — — —� M �
Q o pC z ;'._� .y:r, Zi.2' � b 36.>' I � 00
�- c,-�'h"'?:?;;�',<'` � ,o° � 426>' a7.1' � N
�ti� ;'�:;�'��C}'e` ..� 20. ? Cii}r I �
/ :`'>. ,:;',�,;,�:.';: 5� /
*_ .�.. ;:$p•-,
Q k� •' -'^':;..�y.s:..i
3 �,. � f.,�-�;�-;: : . � . Z
`,R <:v�;::i?�;: 'J.r'�:��':i: 4.p•�
��Q m to' .„. ;.'t�;..%T•�p�q:i. l OFy�:� �u�n� �!':;`,:
N/N 7:r:i" i� � O";::5*� �q�'' 1 p�
� '...'�r.��d.'�...:� �� heV �
4 N ,•. �i;5+,'.•' p Qp
h `' ;�/•';-..:;:KO�iit.."A U O �ol r� ^
�/ a4, �` ,�,�' ....sy:;a::�:�1;; � ooi`�`2� � a d' +im
/�� to `N>'4 .ri:� ..�24�, N a�`� 2� �'"'°'�� a� /� V ��� / 3 .Zec
� 3p?�a� / ::;`r, ��� OOy6� / M^ ' �
/ pp, / o
2 ,p �`� ` � �>' A/C J Q)^Qe � ^�I � �_¢
/ � \ � \ �•O� / `V � Q p��
W�W W� ^' � � ^ ^• �I�
m� O // /{/,�.^ ' O`'.�\ / ^ � � '¢
�i"/N J2 4¢"W ' \ 4js• �j Q�
�� 4� / \ �
�=/�3e �o
`� jo �O 'iD ���7S, ��
��r e�CK 3
� �
� ��
� �.
p� /
/
Llne Tabte
Une � Dlrection Length
L1 N18'07�16"E 2fi.46'
Curve Table
Curve � Length Radlus Delto Chord Bearing Chord
C7 27.61' B5.OD' 1836'41" NOB'48'55�E 27 49'
PREPARED FOR: LEGEND:
ll�M-N(II�IiiN;a s� ON LOT CALCULATIONS - - - BUILDING SE7BACK L1NE
LOT = 7,777 SQ. FT.
�1'���'�u���f LIVING AREA = 1,704 SQ. FT. — cEN�rtuNE
GARAGE = 437 SQ. FT. — RIGHT OF WAY L1NE
BUILDING SETBACKS ENTRY = 53 SQ. FT. � PROPOSE� ELEVAiION
FRONT: 20' LANAI = 0 SQ. FT.
REAR: 15� PA110 = 80 SQ. FT � PROPOSED DRAINAGE FLOW
SIDE: 7.5' � DRIVEWAY = 359 SQ. FT � coNCREh
SIDE STREET: 20' A/C PAD = 12 SQ. FT n/c AIR CONDITIONER
WALKWAY = 27 SQ. FT s/w sioEWAu<
NOTES: IMPERVIOUS = 27�o PI POINT OF INTERSECTION
1 ELEVATIONS SHOWN ARE PER LOT GRADING - 20�2 SQ• FT PC POINT oF CURVATURE
SOD = 5,699 SQ. �7. PT POINT OF TANGENCY
PLANS PROVIDED BY THE CLIENT. RP RADIus POINT
2. ELEVAiIONS ARE BASED ON NAVD 1988 OFF LOT CALCULATIONS PRC POINT OF REVERSE CURVATURE
RIGHT OF WAY = 921 SQ. FT. PCC POINT OF COMPOUND CURVANRE
DATUM. DRIVE APRON = 228 SQ. FT. rn' TYPICAL
PUBLIC S/W = 267 SQ. FT (p� pERCPE�T s�nB
, THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES SOD = 426 SQ. FT. (c) cALcuu�o
ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCl10N OF TornLs Pa PLA7 BooK
iHE PROPOSED HOUSE. REFER TO HOUSE PLAN AND AREA = 8,692 SQ. FT PGS PAGES
OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S0. Ff. SOUARE FEET
LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT DRIVEWAY = 587 SQ. FT. F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY
AND IS FOR INFORMAl10NAL PURPOSES ONLY. SIDEWALK = 294 SQ. FT. F.I.R.M. FLOOD INSURANCE RAiE MAP
NAVD NORTH AMERICAN VERTICAL DANM
THIS IS NOT A SURVEY SOD = 6,125 SQ. FT. D&UE DRAINAGE&UT1l1T!EASEMENTANM
THIS IS A PLOT PLAN ONLY PUE Pueuc uruTY EASEMENTENT
FLOOD NOTE: , SURVEYOR NOTES:
I HAVE EXAMINm THE F.I.R.M. COMMUNITY MAP N0. 12101CO228F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE
DA1ED 09-26-14, ANO FOUND THE SUBJECT PROPERTY APPEARS TO LAND SHOWN HEREON FOR EASEMENTS, RIGHT
LIE IN ZONE X, AREA OUTSI�E THE 100 YEAR FLOOD PLAIN. THE OF WAY, RESTRICTIONS OF RECORD WHICH
SURVEYOR MAKES NO GUARANTEES AS To h1E ABOVE INFORMATION. MAY AFFECT THE T1TLE OR USE OF THE LAND.
PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFlCA710N.
2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN
LOCATED EXCEPT AS SHOWN.
BEARING BASIS:
BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF STABLE 3. NOT VALID WITHOUT THE SIGNATURE AND
WILK AVENUE BEING N78'07�is'E, P� r�aT. THE ORIGINAL RAISED SEAL OF A FLORIDA
I (FIELDDATE:) REVISED: ,
A M E R I C A N UCENSED SURVEYOR AND MAPPER.
SCALE: �•= 30�� � U R �/E Y I N G
�B 8cM A�PPING INC.
I nPPRoveo ar CERTIFlCATION OF AUTHORIZAiION NUMBER LB�6393 FOR
160912 LOT 24, BLOCK 7 3191 MAGUIRE BOULEVARD, SUITE 200 Th{E
Joa No. ORLANDO, FLORIDA 32803 FlRN
(407) 426-7979 '
DRAWNBY: DSB pLOT PLnN 77 12 1s CF �•AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 �A�
7 � �
_
FORM R405-2014 �
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION�
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Hayden 4EH EI v Builder Name: DRH Express Ho es/
Street: ��Q 'LI ���I e �1 I �►�J��� Perm it Office: e�'�.fi���Q���1���
City,State,Zip: Zephyrhills, FL,-�']C�/ Permit Number: ���3 �
Owner: `L`"� � �✓ Jurisdiction: (p �/(P�
Design Location: FL,Tampa 9�/ County:: Pasco(Florida Climate Zone 2)
�� r
1. New construction or existing New(From Plans) 9. Wall Types(2614.2 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=11.0 1285.30 ftz
b.Concrete Block-Int Insul, Exterior R=4.1 996.67 ftz
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ftz
4. Number of Bedrooms 5 d.N/A R= ftz
10.Ceiling Types (1541.0 sqft.) Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ftz
6. Conditioned floor area above grade(ftz) 2605 b.N/A R= ftz
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11 Ducts R ft2
7. Windows(250.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261
a. U-Factor: Dbl,U=0.34 210.00 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftz a.Electric Heat Pump 41.0 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 1.052 ft.
Area Weighted Average SHGC: 0.315 14.Hot water systems
8. Floor Types (1541 0 sqft.) Insulation Area a.Electric Cap:50 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ftz b. Conservation features
b.Raised Floor R=19.0 437.00 ft2 None
c.N/A R= ftz 15.Credits Pstat
Total Proposed Modified Loads: 78.39 pASS
Glass/Floor Area: 0.096
Total Baseline Loads: 79.15
I hereby certify that the plans and specifications covered by Review of the plans and �TKE�T9T
this calculation are in compliance with the Florida Energy specifications covered by this ���� _ �0�,
Code. calculation indicates compliance � ,,,, ' _�'.�� �t„
with the Florida Energy Code. ti rr�r,���;':;:;:;;��,;;'���"�`;, O
PREPARED BY: L'Nk..�,�:.� Before construction is completed � ; "� '� �
►,•�' _��_`�?t: O
DATE: i�-�-�6 this building will be inspected for � I`�f����" �
compliance with Section 553.908 * � ° *
I hereby certify that this building,as designed, is in compliance Florida Statutes. ,t,� ��
with the Florida Energy Code. G�b y�'��
OWNER/AGEN BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn,requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards,is not greater than 0.050 Qn for whole house.
11/7/2016 10:00 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
7
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1a��4�H�El�v�l� �I� n��� Builder Name: DRH Express Homes
Street: �, L S { y Permit Office:
City,State,Zip: Zephyrhills, FL,�C�/ Permit Number:
Owner: `� � �✓ Jurisdiction:
Design Location: FL,Tampa �J�/ County:: Pasco(Florida Climate Zone 2)
.C. �
1. New construction or existing New(From Plans) 9. Wall Types(2614.2 sqft.) Insulation Area
' 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1285.30 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ftz
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ftz
4 Number of Bedraoms 5 d•N�A R= ftz
10.Ceiling Types (1541.0 sqft.) Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ftz
6. Conditioned floor area above grade(ftz) 2605 b.N/A R= ftz
Conditioned floor area below grade(ftz) 0 c.N/A R= ftz
11.Ducts R ftz
� 7. Windows(250.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261
a. U-Factor: Dbl,U=0.34 210.00 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.55 40.00 ftz 12•Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00
- c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftz a.Electric Heat Pump 41.0 HSPF:8.20
SHGC: �
Area Weighted Average Overhang Depth: 1.052 ft.
Area Weighted Average SHGC: 0.315 14.Hot water systems
a.Electric Cap:50 gallons
8. Floor Types (1541.0 sqft.) Insulation Area
a.Slab-On-Grade Ed e Insulation R=0.0 1104.00 ftz EF:0.950
9 b. Conservation features
b.Raised Floor R=19.0 437.00 ftz None
c.N/A R= ft2 15.Credits Pstat
Total Proposed Modified Loads: 78.39 pASS
Glass/Floor Area: 0.096
Total Baseline Loads: 79.15
I hereby certify that the plans and specifications covered by Review of the plans and ���HE�T,q�
this calculation are in compliance with the Florida Energy specifications covered by this � r� _�` p�
Code. calculation indicates compliance � �„ ''� :� a� �
with the Florida Energy Code. ti rrrr,�'�%-;�:��;���� O�
PREPARED BY: LM4..�� Before construction is completed w� - " *"
DATE: il-�-It this building will be inspected for � �-- _!°,��` - ,�
.�t� 9
compliance with Section 553.908 * ,�
I hereby certify that this building,as designed, is in compliance Florida Statutes. ,� ���
with the Florida Energy Code. � � QD�,`�
OWNER/AGEN BUILDING OFFICIAL:
DATE: DATE: - %
:
- Compliance requires certification by the air handler unit manufacturer that the air handler nclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1. ,
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage �
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Gln requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.050 Qn for whole house.
11l7/2016 10:00 AM EnergyGaugeO USA-FlaRes2014'Section R405.4.1 Compliant Software Page 1 of 5
I
-�
;
FORM R405-2014
, PROJECT
Title: Hayden 4EH6 Elev C Bedrooms: 5 Address Type: Lot Information
Building Type: User Conditioned Area: 2605 Lot# 24/1
Owner: Total Stories: 2 BIocWSubDivision: Silverado Ranch
#of Units: 1 Worst Case: No PlatBook:
Builder Name: DRH Express Homes Rotate Angle: 270 Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: Garage R Face W
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
\/ Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Blocki 2605 21579.7
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated
1 Main 1104 9571.7 Yes 1 1 1 Yes Yes Yes
2 2nd Floor 1501 12008 No 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 152.8 ft 0 1104 ftz ____ 0.2 0 0.8
2 Raised Floor 2nd Floor ____ ____ 437 ft2 19 0.5 0 0.5
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor Tested Tested Insul. (deg)
1 Hip Composition shingles 1723 ftz 0 ftz Dark 0.92 No 0.9 No 0 26.6
ATTIC
I V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1541 ftz Y N
11/7/2016 10:00 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
— I
s ;.
FORM F�405-2014
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 40 ftz 0.11 Wood
2 Under Attic(Vented) 2nd Floor 30 Blown 1501 ft2 0.11 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w
1 N=>W Exterior Concrete Block-Int Insul Main 4.1 18 8 8 8 161.8 ftz 0 0.6 0
2 W=>S Exterior Concrete Block-Int Insul Main 4.1 20 8 8 173.3 ft2 0 0.6 0
' _3 S=>E Exterior Concrete Block-Int Insul Main 4.1 39 8 8 8 343.8 ft2 0 0.6 0
4 E=>N Exterior Concrete Block-Int Insul Main 4.1 36 8 8 8 317.8 ft2 0 0.6 0
i _5 N=>W Garage Frame-Wood Main 11 20 4 8 S 176.2 ft2 0.23 0.01 0
_6 W=>S Garage Frame-Wood Main 11 1 S 0 8 8 156.0 ftz 0.23 0.01 0
7 N=>W Exterior Frame-Wood 2nd Floor 11 39 8 8 317.3 ftz 0.23 0.6 0
8 W=>S Exterior Frame-Wood 2nd Floor 11 40 8 8 325.3 ftz 0.23 0.6 0
9 S=>E Exterior Frame-Wood 2nd Floor 11 39 S 8 317.3 ft? 0.23 0.6 0
10 E=>N Exterior Frame-Wood 2nd Floor 11 40 8 S 325.3 ft2 0.23 0.6 0
DOORS
# Omt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>W Insulated Main None 4 3 6 8 20 ft2
2 N=>W Wood Main None .46 2 8 6 8 17.8 ftz
WINDOWS
Orientation shown is the entered orientation => chan ed to As Built rotated 270 de rees .
/ Wall Overhang
�� # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N=>W 1 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None
2 N=>W 1 Vinyl Low-E Double Yes 0.34 0.31 2.5 ftz 6 ft 2 in 0 ft 0 in Drapes/blinds None
3 S=>E 3 Vinyl Low-E Double Yes 0.34 0.31 46.5 ftz 1 ft 0 in 10 ft 6 in Drapes/blinds None
4 S=>E 3 Metal Low-E Double Yes 0.55 0.34 40.0 ftz 1 ft 0 in 1 ft 3 in Drapes/blinds None
5 N=>W 7 Vinyl Low-E Double Yes 0.34 0.31 6.0 ft2 1 ft 0 in 0 ft 6 in Drapeslblinds None
, 6 N=>W 7 Vinyl Low-E Double Yes 0.34 0.31 31.0 ftz 1 ft 0 in 2 ft 6 in Drapes/blinds None
7 S=>E 9 Vinyl Low-E Double Yes 0.34 0.31 62.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None
8 N=>W 7 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None
_ GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 437.038 ftz 437.038 ftz 48.4 ft 8.67 ft 0
1 1/7/201 6 1 0:00 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
�� �
r ''
FORM R405-2014
INFILTRATION
# Scope Method SLA CFM 50 ELA EqLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000368 2517.6 138.21 259.93 .3402 7
HEATING SYSTEM �
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump None HSPF:8.2 41 kBtulhr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity- Air Flow SHR Block Ducts
1 Central Unit None SEER:14 40 kBtu/hr 1200 cfm 0.75 1 sys#1
HOT WATER SYSTEM
# S stem T e SubT e Location EF Ca Use SetPnt Conservation
Y YP YP P
1 Electric None Gara e 0.95 50 gal 70 gal 120 deg � None
9
SOLAR HOT WATER SYSTEM
I FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftZ
DUCTS
/ ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
U # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 261 ft2 2nd Floor 45 ft2 Praposed Qn 2nd Floor ---cfm 130.3 cfm 0.05 0.60 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Coolin r 1Jan r 1Feb r �Mar r 1A r Ma rX�Jun Jul (X�Au Se r �Oct r �Nov Dec
Heating [X]Jan [X�Feb [X]Mar [ ]APr f �May [ ]Jun f�Jul [ I Au9 4�Sep [ ]Oct [X]Nov Dec
Ventin [ ]Jan [ ]Feb [X]Mar [X]A r [ Ma [ ]Jun � Jul [ ]Au � Se [x]Oct [x]Nov Dec
11/7/2016 10:00 AM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 4 of 5 II
�
FORM R405-2014
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 � 2 3 4 5 6 7 S 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 _ 78 78 78 78 78 78 78 78 78 78
Heating(W D) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
11/7l2016 10:00 AM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 5 of 5
, I
J �
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
' The lower the EnergyPerformance Index,the more efficient the home.
, Zephyrhills, FL,
1. New construction or existing New.(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=11.0 1285.30 ft2
b.Concrete Block-Int Insul, Exterior R=4.1 996.67 ftz
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ft2
4. Number of Bedrooms 5 d.N/A R= ftz
10.Ceiling Types Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ftz
6. Conditioned floor area(ft2) 2605 b.N/A R= ftz
7. Windows'* Description Area c.N/A R= ft 2
a. U-Factor: Dbl,U=0.34 210.00 ft2 11•Ducts R ft
a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.55 40.00 ftz
SHGC: SHGC=0.34 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ftz a.Central Unit 40.0 SEER:14.00
SHGC:
d. U-Factor: N/A ftz 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 41.0 HSPF:8.20
Area Weighted Average Overhang Depth: 1.052 ft.
Area Weighted Average SHGC: 0.315
8. Floor Types Insulation Area 14.Hot water systems
z a.Electric Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft EF:0.95
b.Raised Floor R=19.0 437.00 ft2 ,
c.N/A R= ft2 b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building ��KE ST,��,
Construction through the above energy saving features which will be installed (or exceeded) .ti,� - = � fio
in this home before final inspection. Otherwise, a new EPL Display Card will be completed y�ca',,,;''��' _��,.� �,
b a s e d o n i n s t a l l e d C o d e c o m p l i a n t f e a t u r e s. � r m�,�°%' `::.'�:�;���» o�
5 ,,:J
tli .....�5� � Cy
Builder Signature: Date: � ��;�;� , �
�
Address of New Home: �� City/FL Zip: ` �. g'�
G c��,�,��
�:�s�/
*Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation,contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
11/7/2016 10:00 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
� �
' FORM R405-2014
Florida Department of Business and Professional Regulations
Residential Whole Buildin Performance and Prescri tive Methods -
ADDRESS: Permit Number•
Zephyrhills,FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
� 401.3 Energy Pertarmance Level(EPL)display card(Mandatary). The building official shall require that an energy pertormance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
[Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate corripliance for the building.A copy of the EPL display card can be found in Appendix C.
� R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402.4.4
Q R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4 1.1 and R402.4.1.2.The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
• R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4 1 1 shall be installed in
accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction.
Where required by the code official,an approved third party shall inspect all components and verify compliance.
• R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air
i changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an
approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official.Testing shall be pertormed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1 Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures,
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4 Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air
O R402.4.3 Fenestration air Ieakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1.5 L/s/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
0 R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
� R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
� R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance
with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction
ar rough-in testing below
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section
553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following:
1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All
register boots shall be taped or otherwise sealed during the test.
2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g. (25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be
taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm
(85 Umin)per 100 square feet(9.29 m2)of conditioned floor area.
Exceptions:
1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope.
2. Duct testing is not mandatory for buildings complying by Section R405 of this code.
11/7/2016 10:00 AM EnergyGaugeC�USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3
,
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
� R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)
or below 55°F(13°C)shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping insulation.
� R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can turn off the hot-water circulating pump when the system is not in use.
� R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 Yz inches(89 mm)in the hot water distribution line and cold waterline located as close as possible
to the storage tank.
� R403.4.4 Water heater efficiencies(Mandatory).
� R403.4.4.1 Storage water heater temperature controls
. R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum
temperature setting range shall be from 100°F to 140°F(38°C to 60°C).
. R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)
of combustion types of service water heating systems to be turned off.
� R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4 4.2.1.
. R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar pomestic Hot Water System and Component Test Protocol,Collectors in installed solar water
heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
p R403.5 Mechanical ventilation(Mandatary). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment.
� R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shail be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors
which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
• R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is.not less than the
calculated total load,but not more than 1 15 times greater than the total load calculated according to the procedure selected in
Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
1 1/7/201 6 1 0:00 AM EnergyGaugeOO USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3
I
i` ' ,
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
� R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and
shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This
selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the
load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the
� calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of
equipment may be sized in accordance with good design practice.
� R403.6.1.2 Heating equipment capacity
' R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section
R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
. R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.6.1.
' R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.6.1.
� R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
p R403.8 Snow melt system contrals(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall
include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F
� R403.9 Swimming pools,ingraund spas and portable spas(Mandatory). The energy requirements for residential pools and
inground spas shall be as specified in Sections R403.9 1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy
requirements for portable spas shall be in accordance with ANSI/APSP-14.
Q R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
R403.9.1.1 Gas and ail-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum
� thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
� R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in
compliance with this equipment.
Exceptions:
• 1 Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or
at the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or
' solar energy source computed over an operating season.
❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be
high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exceptian: Low-voltage lighting shall not be required to utilize high-efficacy lamps.
� R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
� R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
O R405.2.1 Perfarmance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or
concrete deck roofs do not have sufficent space,R-10 is allowed.
11/7l2016 10:00 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4 1 Com Page 3 of 3
� - �
• .
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Hayden 4EHB Elev C Builder Name: DRH Express Homes
Street: Permit Office:
City,State,Zip: Zephyrhilis,FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL,Tampa
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings,drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walis shall be installed in
substantial contact and continuous alignment with the air barrier.
, Knee walis shall be sealed.
Windows,skylights and doors The space between window/door jambs and framing and skylights and
- framing shall be sealed.
Rim 'oists Rim joists are insulated and include an air barrier.
Floors (including aboVe-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking. �
The air barrier shall be installed at any exposed edge of insulation.
Crawl spaCe walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
s aces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated,and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls,or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fir I An air barrier shall be installed on fireplace walls. Fireplaces shall have
ep ace
gasketed doors
11/7/2016 10:00 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
I
, -�
� I
� `
FORM R405-2014 Duct Leakage Test Report Performance Method
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Form R405 Duct Leakage Test Report
Performance Method
Project Name: Hayden 4EH8 Elev C Builder Name: DRH Express Homes
Street: Permit Office:
City,State,Zip: Zephyrhills, FL, Permit Number:
Design Location: FL,Tampa Jurisdiction:
Duct Test Time: Post Construction
Duct Leakage Test Results
CFM25 Duct Leakage Test Values
� Line System Outside Duct Leakage
1 System 1 cfm25(Out)
2 System 2 cfm25(Out)
3 System 3 cfm25(Out)
4 System 4 cfm25(Out)
5 Total House Sum lines 1-4
Duct System
Divide by
Leakage (Total Conditioned Floor Area)
_ (Q�,Out)
I certify the tested duct leakage to outside, Qn, is KE Sfi
Duct tightness shall be verified by �'� AT
not greater than the proposed duct leakage�n testing to Section 803 of the RESNET � _ � �o�,
l�i F x=��
specified on Form R405-2014. Standards by an energy rater certified in � 'fl•,���¢��'i ` �`` t
E. lflftt.t,'+�y�� �'°:".a`�:�.�`�`��� Q
accordance with Section 553.99, ":f'� •;:,<< " �s
Florida Statutes. a ��, � c�
SIGNATURE: � ,�E� �'
0
�
PRINTED NAME: ��'oIj����'
DATE: BUILDING OFFICIAL:
DATE:
11/7l2016 10:00 AM EnergyGaugeOO USA-FlaRes2014 -Section R405.4 1 Compliant S Page 1 of 1
a
�aEgs'�F Manual S Compliance Report Job:
QP q'� Date: Oct 10,2014
; .�: �,a Entire House Bv:
,�;�
�•�:� Progressive Air Systems
�''���5.�a
5907 Dasher ct,Port Richey,FI 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669
� • ' 9 i
For: Dr Horton/Express
Lot 24 Blk 1 Silverado, Zephyrhilis, FI
• • • • �
Design Conditions
Outdoor design DB: 91.2°F Sensible gain: 32055 Btuh Entering coil DB: 76.4°F
Outdoor design WB: 77.1 °F Latent gain: 4144 Btuh Entering coil WB: 63.2°F
Indoor design DB: 75.0°F Total gain: 36199 Btuh
Indoor RH: 50% Estimated airflow: 1367 cfm
Manufacturer's Pertormance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: CH14NA042`*"*A+FB4CNP042
Actual airflow: 1367 cfm
Sensible capacity: 32442 Btuh 101%of load
Latent capacity: 6271 Btuh 151%of load
Total capacity: 38713 Btuh 107%of load SHR: 84%
• • •
Design Conditions
Outdoor design DB: 40.0°F Heat loss: 27149 Btuh Entering coil DB: 69.5°F
Indoor design DB: 70:0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: CH14NA042**"A+FB4CNP042
Actual airflow: 1367 cfm
Output capacity: 37299 Btuh 137%of load Capacity balance: 37 °F
Supplemental heat required: 0 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 1367 cfm
Output capacity: 8.6 kW 108%of load Temp. rise: 18 °F
The above equipment was selected in accordance with ACCA Manual S.
.� wri htsoft� 2016-Nov-0412:07:56
�. 9 Right-Suite�Universal 2013 13.0.11 RSU18520 Page 1
�� ..\Wrightsoft Files\E�ress homes\Hayden-4EHB.rup Calc=MJ8 House faces: W
, ,
� ����Ess'"�q Load Short Form Job:
Q '4 Date: Oct 10,2014
a�:� Entire House Bv:
��`: � .
�-��,�: Progressive Air Systems
S'g�EmS.
5907 Dasher ct,Port Richey,FI 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669
i • • � S
For: Dr Horton/Express
Lot 24 Blk 1 Silverado, Zephyrhills, FI
, - e s •
Htg Clg Infiltration
Outside db(°F) 40 91 Method Simplified
Inside db(°F) 70 75 Construction quality Semi-tight
Design TD (°F) 30 16 Fireplaces 0
Daily range - L
Inside humidity (%) 50 50
Moisture difference(gr/Ib) 26 54
HEATING EQUIPMENT COOLING EQUIPMENT
Make Carrier Make Carrier
Trade CARRIER Trade CARRIER
Model CH14NA042****A Cond CH14NA042*'`**A
AHRI ref 6803257 Coil FB4CNP042
AHRI ref 6803257
Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER
Heating input Sensible cooling 30750 Btuh
Heating output 38500 Btuh @ 47°F' Latent cooling 10250 Btuh
Temperature rise 26 °F Total cooling 41000 Btuh
Actual air flow 1367 cfm Actual air flow 1367 cfm
Air flow factor 0.050 cfm/Btuh Air flow factor 0.043 cfm/Btuh
Static pressure 0.56 in H20 Static pressure 0.56 in H20
Space thermostat Load sensible heat ratio 0.89
�, ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ftz) (Btuh) (Btuh) (cfm) (cfm)
kitchen/living 608 7370 8460 371 361
bed 2 164 2960 1938 149 83
powder 59 968 367 49 16
flex 156 3106 3211 156 137
foyer 75 1443 917 73 39
stairs 44 0 0 0 0
bed4 181 1647 2131 83 91
bed3 184 1965 3356 99 143
wic 60 143 177 7 8
wic 2 32 706 911 36 39
m suite 277 2507 4064 126 173
bath 135 355 355 18 15
upstairs living 234 1366 2606 69 111
stairs 2 50 0 0 0 0
bed5 175 1606 2088 81 89
laundry 41 368 917 19 39
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
.� wri htsoft� 2016-Nov-0412:07:56
,.,.,, 9 Right-Suite�Universal 2013 13.0.11 RSU18520 Page 1
� \Wrightsoft Files\E�ress homes\Hayden-4EHB.rup Calc=MJS House faces: W
�
1
a/c 19 0 0 0 0
bath 3 96 639 559 32 24
hall 63 0 0 0 0
Entire House d 2651 27149 32055 1367 1367
Other equip loads 0 0
Equip. @ 1.00 RSM 32055
Latent cooling 4144
TOTALS 2651 27149 36199 1367 1367
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
.c. wri htsoft° 2016-Nov-0412:07:56
,�, 9 Right-Suite�Universal 2013 13.0:11 RSU18520 Page 2
�� \Wrightsoft Files\E�ress homes\Hayden-4EHB.rup Calc=MJS House taces: W
� FC�RM R4�05-2014
RES/DENTIAL ENERGY CONSERVAT/ON CODE DOCUMENTATION CHECKLIST
Florida Departmenf of Business and Professional Regulafion
Simulafed Performance A/ternative(Performance)Method
Applications for compliance with the 2014 Florida Building Code,Energy Conservation via the
residential Simulated Performance method shall include
❑ This checklist
' ❑ A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, e-ratio and the pass or fai!status along with summary
areas and types of components, whether the home was simulafed as a worsf-case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report(1 page)and an input summary checklist that can
be used for field verification (usually 4 pages/may be greater).
❑ Energy Performance Level(EPL) Display Card(one page)
❑ Mandafory Requiremenfs(fhree pages)
Required prior to CO for the Pertormance Method;
❑ Air Barrier and Insulation Inspecfion Component Criteria checklist(Table R402.4.i.1 -
one page)
❑ A completed Envelope Leakage Test Report(usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage; then a completed
Form R405 Ducf Leakage Test Report(usually one page)
EnergyGauge�-USRCZB v5.1
11/7/2016 10:14:13 AM Page 1 of 1