Loading...
HomeMy WebLinkAbout17-18390 CITY OF ZEPHYRHILLS 5335-STH STREET (813)780-0020 �$3�� BUILDING PERMIT SINGLE FAMILY RESIDENTIAL .'� � PERMIT INFORMATION - LOCATION INFORMATION � Permit#:18390 Issued: 4/20/2017 Address: 36173 STABLE WILK AVE ' Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 228,052.20 Total Fees: 11,223.69 Subdivision: SILVERADO Amount Paid: 11,223.69 Date Paid: 4/20/2017 Parcel Number: 04-26-21-0070-00100-0220 CONTRACTOR INFORMATION OWNER INFORMATION Name: D R HORTON INC Name: D R HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELECOM DR TAMPA, FL. 33637 TAMPA, FL. 33637 Phone: Lic: Phone: (813)549-1968 Work Desc: CONSTRUCT SINGLE FAMILY HOME 2,238 SQ FT APPLICATION FEES - BUILDING FEE 972.49 ELECTRICAL FEE 196.88 PLUMBING FEE 131.25 MECHANICAL FEE 91.88 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfd 1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 ' � �c G�� : �� �o ��a�T� � ���s�-✓ Ins ections Re uired FOOTER 2ND ROUGH P MB MIS INSULATION CEILI FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application. All work shall be performed in�accordance with City Codes and Ordinances. NO OCCUPANCY�EFORE C.O. NO OCCUPANCY BEFORE C.O. � CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO � CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER •m _ o. ,,.. _ :.:�. _ � � _, r,,::.+. .�,� _ � _ . , �9; '``�.,,���� ;�.I; City of Zephyrhills � BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: �` � �j� Date Received: �� � --'� 7 Site: � ��� �'`�C'.���.Gl,�� �.�`'l� , Permit Type: ''�'1.G� !� �'Y�r G �i���� � Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ I � G -� This comment sheet shall be kept with the permit and/or plans. � � ; � ��� ' � Kalv' —Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) i iiiiii iiiii iiiii�iiii iiiii iiiii iiiii iiiii�iiii iii�i iiii iiii 2017059571 Permil No. Parcel ID No � /_��!�I''�`�7 D-D�'"������ ' I NOTICE OF COMMENCEMENT State of�/�rl GZ_ Counry of QS l_S✓ THE UNDERSIGNED hereby gives notice that(mprovement will be made to certaln real property,and in accordance with Chapler 713,Ftorida Statules, the following informaUon is provided in lhis Notice ot Commencemenl: � r � ,/ 1 Descrlplion of Property: Parcel Identification No. I � ��/ StreetAddress: � � � � S� � , 2. General Descriptlon of Improvement I 3. Owner Information or Lessee information if Ihe Lessee conlracled for lhe improvemenl: I� �7 Q�/'�r,n �'n� 1?(nOz "�n.I��r�M �r �vu�0a ����03�" �L Address r Cily Stale Interest in Property: T e� �r l�l��� Name of Fee Simple Titlehotder: (If differenl from Owner lisled abovej `C f' U � z _ � Address n ' I City State � W � �� W -�-� Contractor: �• Y`�• N('')I��n ��l(° � � � — J U ��� ame��il e�A1� �� �(`�IMrOQ 33G� �L � Z� O {_— J >' Address City Slale �Q U � J N O � � = Q � � Conlraclor's Telephone No. �``�0 � W F" W 5. Surely: �� � � � z (� � � � N� ,�y. 0 f-- 0 — O }- w � � U� U Address / City Stale z Q � � Amount of Bond: $��/ � Telephone No. o F a W Q Y 6. Lender: A���- () _ � U p / Name w Q ~' F-- JQ J � . Address City Slale � �" U m p � U Lender's Telephone No. �..° � w = z � J � � � � _ ¢ W 7 Persons wilhin lhe Slate of Florida designated by[he owner upon whom notices or olher documenls may be served as provided by J W Q � p Z I Section 713.13(t)(a)(7),Florida Statules: /' u- () U � �" O � Q1�1�� (`7(9��_ u- O p p Name � F- Z � � � 0 0,� `��-�Pl�L�I �r `r�G� � ��.��- � t.w- � w � w � A dress q il�j State � Telephone Number of Designated Person: �,1' ����� r�� z c~i) E-=- � 0 � a m B. In additfon lo himself,lhe ovmer designates of_ to receive a copy of the Llenors Nolice as provided in Section 713.13(1)(b),Florida Statules. � � Telephone Number ot Person or Entity Designaled by Owner• �s� �o � 8. Ezpiralion dale of Notice of Commencemenl(the expiration dale may nol be before lhe complefion of conslruction and final payment lo the �� • • s �Q ' contreclor,but will be one year from the dele of recording unless a diBerent date is specified): � ` � WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EJ(PIRATION OF THE NOTICE OF COMMENCEMENT �� ,r,a� � a�� ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN v ,� � � RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPER'fY. A NOTICE OF COMMENCEMENT MUST BE � RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT • � � '� "1��� '�' �� WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT ��s � ��4, � Under penalty ofperjury,I declare thal I have read the foregoing nolice of commencement and ihal lhe facls slaled therein are true to lhe besl � ��/ �-�' .' � o(my knowtedge and belieL ��o -- � ��•�� STATE OF FLORIDA �B_ COUNIY OF PASCO "y • p � Signa re o Ovmer or L ssee,or Owner's or Lessee's Authorized ���y • „S-��, Rcpt:1856543 Rec: 10.00 Office irectorlPartnerlManager � D5: 0.00 IT: 0.00 1-I�f �lf'P�/��l - �•��yn��l�i1� 04/20/2017 J. R., Dp4.y Clerk Signatory's7itle/Ottice ' The foregoing Inslrumenl was acknowledged betore me this�day of iY(//� 1 ,20�y 1�I�i Q 1� ��Po[../c.it' � �-+� as���'� �PIf��Ct/�o� (type of aulhority,e.g.,officer,Irustee,attorney in facQ for � �1 i I 1_). - •t'10 f n Tn t (name ol pa y on b half o whom instrument was execuledj. , I Personally Known�,0�Produced Identificalion❑ Nolary Signalure Type of Ideniificalion Produced Name(Print) PPULR S 0'NEII.Ph.D PRSCO CLERK & COMPTROL�ER 04/20/2017 38 m PG of 1 OR BK 9�2,� 665 �°�'¢� NoteryPubllcSteteMFlorida ��� Mlchelle Moyes My Commleslon GG 057321 ovn Explrea 12/21/2020 wpd e la/bcs/nol icecommencementyc053046 _ � I ._` , � , � � � � PASCO COUNTY, FLORIDA ; � Permit No. - �j� 6 � Date Permitted —�_ � Builder Name/Owner Name � ¢r��Q Control# � County Parcel No. ��(--Z�o y���Q"j�_�j��� d�SubDiv: � f S �U2ra0�0� . Address/Location _���'Z 3 C�'�1� W� � k � � i Classification/Type of Use c���'1(�' � �-aiy.n, j� �•y�_ ; � � TRANSPORTATION IMPACT FEE Rate: � � ' Sq Ft Unit: Z� Z-3� •� Exempt � Yes � No How Determined � ; � Impact Fee Amount _$ �,(��2.v� Zone No. TAZ: —_ , SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ � �7� � (057) Mobile Home ' (058) Other Residential . � ' , � 123) Collection Fee � Exempt [� Yes Q No � How�Determined � ' i PARKS.AND RECREATION FEE ;� Land Account Land Credit Land Total i� ' � � Recreation Account Recreation Credit � �_ Recreation Total i � Zone TOTAL AMOUNT $ 7�g��. i Exempt � Yes � No How Determined ' - .• LIBRARY FEE ' Land Account Land Credit • � Land Total ; , Facility Account __ Facility Credit � " Facility Total � Exempt � Yes � No How Determined Total Amount �_ RESOURCE FEE ' � TOTALAMOUNT ERU � i Prepared By � ° Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION ' PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE ' RECEIPTED FOR BY A CENTRAL PERMITT NG OFFICE OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence,but slmply receipt of a copy of this form,placing the buflding permft owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY ' RECEIPT NO. __ DATE �_ gY � . � , , I � e � FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Pro ect Name: Aria Elevatio Dc 1 ��i ' I Builder Name: DRH Ex ress Homes / / Street: � ��'�J�I��-/�I� v��� Permit Office: �`�U�-�j�l'1tr�Os' City,State,Zip: Zephyrhills,FL��(,�( � / Permit Number: (� � Owner: �V Jurisdiction: 6 t[bOt� Design Location: FL,Tampa 22/ County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1658.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1372.20 ftz b.Frame-Wood,Adjacent R=11.0 286.00 ftz 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number af Bedrooms 3 d.N/A R= ftz 5. Is this a worst case? No 10.Ceiling Types (1672.0 sqft.) Insulation Area Z , a.Under Attic(Vented) R=30.0 1672.00 ft 6. Conditioned floor area above grade(ft2) 1672 b.N/A R= ft2 Conditioned floor area below grade(ftz) 0 c.N/A R= ft2 11 Ducts R ftz 7. Windows(182.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 392 a. U-Factor: Dbl,U=0.34 142.00 ftz SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ftz 12•Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 c. U-Factor: N/A ftz SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 4.985 ft. � Area Weighted Average SHGC: 0.317 14.Hot water systems 8. Floor Types (1672.0 sqft.) Insulation Area a.Electric Cap:50 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ftz b. Conservation features b.N/A R= ftz None c.N/A R= ftz 15.Credits Pstat Total Proposed Modified Loads: 49.02 pASS Glass/Floor Area: 0.109 Total Baseline Loads: 57.14 I hereby certify that the plans and specifications covered by Review of the plans and D�THE STq� this calculation are in compliance with the Florida Energy specifications covered by this � ,��, '�_ ;� O�, Code. calculation indicates compliance r,, �i,, '' w;,��,�` M' with the Florida Energy Code. N rrr„�:., ���,�:°;;;��;•�"„�O ..,,.�. . PREPARED BY: LMk.�.M:,.. Before construction is completed � DATE: II-7-16 this building will be inspected for � �'�I`����,�`" ,� compliance with Section 553.908 * t:' ° ,� I hereby certify that this building, as designed, is in compliance Florida Statutes. ✓ ��� with the Florida Energy Code. �D{ry�i'� OWNER/AGEN . BUILDING _ F.1�,1� ' DATE: DATE: G� - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. �I 11/7/2016 9:38 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 , � FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Aria Elevatio D 1 ��� �/ ��� Builder Name: DRH Express Homes Street: � ��"���I�w�I �� C Permit Office: City,State,Zip: Zephyrhills, FL��(,1' � / Permit Number• Owner: �V Jurisdiction: Design Location: FL,Tampa Z2/ County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(16582 sqft.) Insulation Area 2. Single family or multiple family Single-family 'a.Concrete Block-Int Insul,Exterior R=4.1 1372.20.ftz b.Frame-Wood,Adjacent R=11.0 286.00 ftz 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R_ ftZ 10.Ceiling Types (1672.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1672.00 ftz 6. Conditioned floor area above grade(ftz) 1672 b.N/A R= ftz � Conditioned floor area below grade(ftz) 0 c.N/A R= ft2 11.Ducts R ftz 7. Windows(182.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 392 a. U-Factor: Dbl,U=0.34 142.00 ftz SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 c. U-Factor: N/A ftz SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a.Electric Heat Pump 28.6 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 4.985 ft. Area Weighted Average SHGC: 0.317 14.Hot water systems a.Electric Cap:50 gallons 8. Floor Types (1672.0 sqft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ftz b. Conservation features b.N/A R= ftz None c.N/A R= ftz 15.Credits Pstat Total Proposed Modified Loads: 49.02 ' pASS Glass/Floor Area: 0.109 Total Baseline Loads: 57.14 I hereby certify that the plans and specifications covered by Review of the plans and ��THE ST,q� this calculation are in compliance with the Florida Energy specifications covered by this ��y =__ � p = Code. calculafion indicates compliance ��'�'�„°''� ';;�,� �,+ ,� ,o � with the Florida Energy Code. ti rx�r;.,�•-;:;;f:,''��;;��„ p� PREPARED BY: �'�.�•� Before construction is completed � ' ., DATE: II-7-16 this building will be inspected for � ���j����- . �,,d compliance with Section 553.908 * " ° ,� I hereby certify that this building,as designed, is in compliance Florida Statutes. ,t� ��,5 with the Florida Energy Code. �� OWNER/AGEN . BUILDING O CIAL: DATE: DATE: ���f'� - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist_in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 11l7/2016 9:38 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT I Title: Aria Elevation D Bedrooms: 3 Address Type: Lot Information Building Type: User Conditioned Area: 1672 Lot# 2211 Owner: Total Stories: 1 Block/SubDivision: Silverado Ranch #of Units: 1 Worst Case: No PlatBook: i Builder Name: DRH Express Homes Rotate Angle: 270 Street: Permit Office: Cross Ventilation: County• Pasco Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: Garage R Face W CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blocki 1672 14496.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 Main 1672 14496.2 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 192.68 ft 0 1672 ftz ____ 0.5 0 0.5 ROOF � Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor Tested Tested Insul. (deg) 1 Hi Com osition shin les 1870 ft2 0 ftz Dark 0.92 No 0.9 No 0 26.6 P P 9 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1672 ft2 Y N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1672 ftz 0.11 Wood 1 1/7/201 6 9:38 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>W Exterior Concrete Block-Int Insul Main 4.0999 18 0 8 8 156.0 ftz 0 0.01 0 2 W=>S Exterior Concrete Block-Int Insul Main 4.0999 44 0 8 S 381.3 ftz 0 0.01 0 3 S=>E Exterior Concrete Block-Int Insul Main 4.0999 38 S 8 S 335.1 ft2 0 0.01 0 4 E=>N Exterior Concrete Block-Int Insul Main 4.0999 57 8 S S 499.8 ftz 0 0.01 0 _5 N=>W Garage Frame-Wood Main 11 20 0 S 8 173.3 ftz 0.23 0.01 0 _6 W=>S Garage Frame-Wood Main 11 13 0 S 8 112.7 ft2 0.23 0.01 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>W Insulated Main None .4 3 6 8 20 ftz 2 N=>W Wood Main None .46 2 8 6 8 17.8 ftz WINDOWS Orientation shown is the entered orientation => chan ed to As Built rotated 270 de rees . / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>W 1 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 2 ft 8 in 0 ft 1 in Drapes/blinds Exterior 5 2 N=>W 1 Vinyl Low-E Double Yes 0.34 0.31 2.5 ftz 7 ft 8 in 0 ft 2 in Drapes/blinds Exterior 5 3 S=>E 3 Vinyl Low-E Double Yes 0.34 0.31 62.0 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5 4 S=>E 3 Vinyl Low-E Double Yes 0.34 0.31 31.0 ftz 8 ft 0 in 0 ft 1 in Drapes/blinds Exterior 5 5 E=>N 4 Metal Low-E Double Yes 0.55 0.34 40.0 ftz 12 ft 0 in 0 ft 8 in Drapes/blinds EMerior 5 6 E=>N 4 Vinyl Low-E Double Yes 0.34 0.31 15.5 ftz 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5 GARAGE # FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 432.177 ftz 432.177 ftz 49 ft 8.67 ft 0 >. INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000386 1691.2 92.85 174.61 .2892 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 28.6 kBtu/hr 1 sys#1 1 1/7/201 6 9:38 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts - 1 Central Unit None SEER:14 28.6 kBtu/hr 858 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation i 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None I SOLAR HOT WATER SYSTEM I� FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS / ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 392 ftz Main 40 ftz Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb Mar A r Ma Jun Jul Au Se Oct Nov Dec Heatin9 Jan �Feb �Mar E�APr f �May f�Jun ��Jul 4�Au9 4�SeP E�Oct �Nov �Dec Ventin Jan Feb Mar [X]A r [ Ma [ Jun Jul [ Au � Se �X�Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 SO SO 80 80 PM SO 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 � 68 68 68 66 66 1 1/7/201 6 9:38 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 86 - The lower the EnergyPerformance Index,the more efficient the home. , Zephyrhills, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area li 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1372.20 ftZ ' b.Frame-Wood,Adjacent R=11.0 286.00 ft 3. Number of units,if muitiple family 1 c.N/A R= ftz 4. Number of Bedrooms 3 d.N/A R= ftz 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1672.00 ftz 6. Conditioned floor area(ft2) 1672 b.N/A R= ftz 7. Windows** Description Area c.N/A R= ft Z a. U-Factor: Dbl,U=0.34 142.00 ftz 11•Ducts R ft a.Sup:Attic,Ret:Main,AH:Main 6 392 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ftz SHGC: SHGC=0.34 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a.Central Unit 28.6 SEER:14.00 SHGC: d. U-Factor: N/A ftz 13.Heating systems kBtu/hr Efficiency SHGC• a.Electric Heat Pump 28.6 HSPF:8.20 Area Weighted Average Overhang Depth: 4.985 ft. Area Weighted Average SHGC: 0.317 8. Floor Types Insulation Area 14 Hot water systems z a. Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ft EF•0.95 b.N/A R= ftz c.N/A R= ftz b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building �,�KE S�,qr Construction through the above energy saving features which will be installed (or exceeded) tio - � � �o in this home before final inspection. Otherwise, a new EPL Display Card will be completed ��v�`,,,�''�'i ��-�,.� � . based on installed Code compliant features. � r+�,�,���:; =:.��°:��,��'-`„ o� .f Builder Signature: Date: l� � 7;�'��' , � * �' s Address of New Home: City/FL Zip: ; r�, c,� cflb�.�o �s�i/ ''Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. *'`Label required by Section R303.1.3 of the Florida Buiiding Code, Energy Conservation, if not DEFAULT. 1 1/7/201 6 9:38 AM EnergyGauge�USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Buildin Performance and Prescri tive Methods ADDRESS: Permit Number: Zephyrhills, FL, MANDATORY REQUIREMENTS See individual code sections for full details. � 407.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy pertormance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. � R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4 4 Q R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installatian. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1 Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures, 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4 Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer Exceptian: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. � R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. � R403.1.3 Heat pump supplementary heat(Mandatary). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. � R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99, Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1 Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 L/min)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1 The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 1 1/7/201 6 9:38 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4 1 Com Page 1 of 3 FORM R405-2014 Mi4NDATOi�Y REQUIREMENTS - (Continued) � R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Pratectian of piping insulation. � R403.4.1 Circulating hot water systems(Mandatary). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. � R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3�/z inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. � R403.4.4 Water heater efficiencies(Mandatory). � R403.4.4.1 Storage water heater temperature controls . R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). . R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off � R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1 . R403.4.4.2.1 Salar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar pomestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. � R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and � indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Coaling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 1 1/7/201 6 9:38 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) � R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominai,rating-test value and shall not be used for equipment sizing.Manufacture's expanded pertormance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1 Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. � R403.6.1.2 Heating equipment capacity ' R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1 1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. . R403.6.1.2.2 Electric resistance furnaces. Electric resistance fumaces shall be sized within 4 kW of the design - requirements calculated according to the procedure selected in Section R403.6.1. ' R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric bumers shall not be less than the design load calculated.in accordance with Section R403.6.1 � R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1 A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,ingraund spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14 Q R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. � R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. � R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps. Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1 Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. , O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surtace or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or ' solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. 0 R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously buming pilot lights � R405.2 Pertormance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Pertormance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space, R-10 is allowed. 1 1/7/201 6 9:38 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Aria Elevation D Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Tampa COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attiC The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim 'oists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow Cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity s aces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. EleCtrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 1 1/7/201 6 9:38 AM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 1 � � Q��oa�ss�vF'0,� Manual S Compliance Report Da e: Oct 10,2014 s r Entire House Bv� :�;;�' � �•�:� Progressive Air Systems ����5,�� 5907 Dasher ct,Port Richey,FI 34668 Phone:727-847-3898 �Fax:727-815-3399 License:CAC033669 � • ' 9 • For: DR Horton/Express homes Lot 22 Blk 1 Silverado, Zephyrhills, FI • • • s s Design Conditions � Outdoor design DB: 91.2°F Sensible gain: 21334 Btuh Entering coil DB: 76.1°F Outdoor design WB: 77.1°F Latent gain: 2877 Btuh Entering coil WB: 63.0°F Indoor design DB: 75.0°F Total gain: 24211 Btuh Indoor RH: 50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB030*""`A+FB4CNP030 Actual airflow: 1000 cfm Sensible capacity: 23532 Btuh 110%of load Latent capacity: 3786 Btuh 132%of load Total capacity: 27318 Btuh 113%of load SHR: 86% • • • Design Conditions Outdoor design DB: 40.0`F Heat loss: 20312 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB030"'""A+FB4CNP030 Actual airflow: 1000 cfm Output capacity: 25625 Btuh 126%of load Capacity balance: 37 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1000 cfm Output capacity: 6.4 kW 108%of load Temp. rise: 20 °F The above equipment was selected in accordance with ACCA Manual S. �- wri htsoft� 2016-Nov-0412:29:46 �A� 9 Right-SuiteC�Universal 2013 13.0.11 RSU18520 Pa e 1 9 .on\Wrightsoft Files\E�ress homesVlria 4EAB.rup Calc=MJ8 House faces: W i 1. � �oo�Ess,�Eq, Load Short Form Job: Q � Date: Oct 10,2014 .�v r p�. Entire House Bv� �� � �•�•� Progressive Air Systems s'��MS.�'' . 5907 Dasher ct,Port Richey,FI 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 � i ' • 0 For: DR Horton/ Express homes Lot 22 Blk 1 Silverado, Zephyrhills, FI i - o A e Htg Clg Infiltration Outside db(°F) 40 91 Method Simplified Inside db(°F) 70 75 Construction quality Semi-tight Design TD (°F) 30 16 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference(gr/Ib) 26 54 ' HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB030**'*A Cond CH14NB030""*"A AHRI ref 6804001 Coil FB4CNP030 AHRI ref 6804001 Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 22500 Btuh Heating output 29600 Btuh Qa 47`F Latent cooling 7500 Btuh Temperature rise 27 °F Total cooling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.88 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) M bed 237 3345 3280 165 154 dining 202 2812 3947 138 185 greatroom 257 3318 4133 163 194 M wic 49 744 338 37 16 wc 25 372 169 18 8 M bath 135 1579 845 78 40 kitchen 146 170 1547 8 73 laundry 42 252 843 12 40 A/C closet 14 16 25 1 1 bed3 154 1615 1675 80 79 foyer 162 1679 1494 83 70 bath2 60 659 322 32 15 bed2 166 3751 2716 185 127 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ,� wri htsoft¢ 2016-Nov-04 1229:46 9 Right-SuiteCa Universal 2013 13.0.11 RSU18520 Page 1 �CA ...on\Wrightsoft FileslExpress homes�Aria 4EAB.rup Calc=MJS House faces: W �- i Entire House d 1647 20312 21334 1000 1000 Other equip loads 0 0 Equip. Qa 1.00 RSM 21334 Latent cooling 2877 TOTALS 1647 20312 24211 1000 1000 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .� wri htsoft� 2016-Nov-0412:29:46 ,.,�� 9 Right-Suite�Universal 2013 13.0.11 RSU18520 Page 2 � .on\Wrightsoft Files\Express homes�Aria 4EAB.rup Calc=MJ8 House iaces: W FORM R405-2014 RES/DENTIAL ENERGY CONSERVAT/ON CODE DOCUMENTAT/ON CHECKLIST Florida Department of Business and Professional Regulafion Simulated Performance Alternative(Performance)Mefhod Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the residential Simulated Pertormance method shall include ❑ This checklist ❑ A Form R405 report that documents that fhe Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicafing home address, e-ratio and the pass or fail stafus along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of fhe compliance software tool, name of individual completing the compliance report(1 page)and an input summary checklist that can be used for field verification(usually 4 pages/may be greater). ❑ Energy Performance Level(EPL)Display Card(one page) ❑ Mandatory Requirements(three pages) Reguired prior to CO for fhe Performance Method: ❑ Air Barrier and Insulafion Inspection Componeni Criteria.checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage" then a completed Form R405 Duct Leakage Test Report(usually one page) EnergyGauge�-USRCZB v5.1 11/7/2016 9:49:29 AM � Page 1 of 1 � - - - Crystal Reports Viewer Page 1 of 1 � ' r: Parameters�°-.+�Grou Trea� ;: � 1 !1 i� Gi 10D% CRYSTAL fl@i!ORT9' rJ� c�.�7 ,t. P • f� ���.iC-�47 _�; l.foin RepoA 1''�"'_� �� r �r(/� �J"CJ,� � PASCO COUNTY I D vv BUILDING CONSTRUCTION SERVICES _ `-.yb^"� � 8737 Cilizens�rive Sulla 230. Date:7242017 �3���, .' , New Por1 Richey,FL 34654 ;'.,•. 727•847-8127 � � . ** NOT A PERMIT ** Receipt#: 1694895 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE p FEE AMOUNT PAID RECEIPT p DATE ImpaC Fee Residenlial Solid 8450-363D00 29.39 1272165 529.39 529.39 1694895 724/17 Wasle Single Family 2HILLS SW PM18J00. � TOTALS: 529.39 529.39 Receiot p Paltl Bv Check p� CC Auth ff Cashler ID Wmkslalion Recelot Date Amt Paid 1694895 Check 612913 294 BCCCP3BW 07242017 529.39 ' Totai Paymants: 529.79 Pavor Add�re�ss_y���-�-.^^�-.-a Phone D R HORTON 3�61J� T1S ABLEfWI'LKA'�VE � Com s• HILL SW PYMNT 0426210070001000220 � MyReponslrepoAslIPRODUCTIONIPASCOlReceiplP05 V4.rpt 7/242017 Page 7 01 7 � http://crystal3.accela.com/myrepoi•ts/adapter/XReportmp.aspx?re... 7/24/2017 Check Number 0590462 CITY OF ZEPHYRI�IILLS-PERMITTING� � � Date OS/18/17 3921 SOUTH AVENUE DRH Inc. Controlled Disb Stub 1 of 1 2149668 PO Numb invoice Number Subdv Lot# Lot Address Cost Cde Legal Desc Gross Deductions Amount Paid -------- ---------—-—- ----- ---- -------r�--- ' l 391630017REDTAG 39163 0017 36173 STABLE WILK AVENUE 73/59 40 00 40 00 \ �' ----------- ----------- ---------- I 40 00 '40.00 ' _ � � ��� � � ''� � � � � ti ' J � � i � � , i� , � ' / \ � J ' � , r _ .. ,a _. F�'IE �3�� �i GE'j.t�lj'i�II1�5 ��,51�J?iQi� v�qo1� �1i fi�.:r� � r{C,n: nc,_�+yr;� �v[i, �f]iy,�t 11 i t:�: G0,GL� �, ---------------------------------------._ ic�t��> •�GoQ� C�a=_.I��� ���,v 4 �� f� '=tc,O o . ,.� > ,}—r; i::tE�=I{o i�o�v ��Q4�% r2�� T3jL��4?�..��.4;�i. [itf�,rr^ �i3.i�G i�ii•3i�jc� L�aLit�1 nr�%tiqu� i?i�; i':.yRti��lr.i�;� �:��5�=Gii;F?' �-�t t V����Q�; C_5!!�CY� �_�i[i�G_. :i*.3+lC+i i°. .���:�:,_' '•-""""'-'.�.'.r""...""'..........u���u......�.. I f �� D.R. Horton, Inc. -Tampa Division Check Request- Permit Check Request City of Zephyrhills-2149668 f�,p�� ��/� �J j Object Cost Code Youct�er:lq •AP� Code(4 (5 digits.2 us:eqnly. .:Check# Amount Description BusinessUnit(9digits) digits) digits) �'"�"�""' 1533 40010.02 �' . ............• ao.00 red tag 391630017 1533 40010.02 .............. ..............: .............. .............. ..............: ..............: .............. I :.............: ..............: ..............: .............. .............. .............. .............. ..............: .............. .............. ..............: .............. ..............: ...............� � Total $40.00 Submitted By: Date: Approved By: Date: I alsaeo-oozo ' 'City of Zephyrhilis Permit Application F�-a1s-�ao-oozi Building Department � Date Received � � Phone Contact for Permitting -- Trr7�rr-r Owner's Name � �a � �-. � Owner Phone Number ��(�Z . �- �•�� �J Owner's Address �a6oa z��e�� �" ��' �G-n-►�J��� �/Owner Phohe Number Fee Simple Titleholder Name C.,r► � Owner Phone Number ! - -- Fee Simple Titleholder Address JOB ADDRESS r�!�I��� ��� �J���L�/ / �/� /�I.,� LOT# �� SUBDIVISION S1�l l���'� �p PARCEL ID# ��}-����' �a �d � jfC����"�4'�� (OBTAINED FROM PROPEFiTYTAX NOTICE) WORK PROPOSED �NEW CONSTR B ADD/ALT � SIGN � � DEMOLISH INSTALL REPAIR PROPOSED USE �� SFR Q COMM 0 OTHER TYPE OF CONSTRUCTION � BLOCK Q FRAME 0 STEEL .Q DESCRIPTION OF WORK n�� 5•��<<���'+'�-� � I�S�c��C� � ►�J�� .I�b�"�"� � '�J�a` ' BUILDING SIZE S�FOOTAGE /���„1 � � HEIGHT � I1T1"rr1"1T , �BUILDING $ 1((,�� CI�G'j VALUATION OF TOTAL CONSTRUCTION �ELECTRICAL $ AMP SERVICE � PROGRESS ENERGY � W R.E.C. ������ � �PLUMBING $ ����F ;. I /'� ��� l./! / / 0 MECHANICAL $ �J��� VALUATION OF MECHANICAL INSTALLATION _ � OGAS � ROOFING Q SPECIALTY 0 OTHER FINISHED FLOOR ELEVATIONS ��� + � ` FLOOD ZONE AREA DYES NO •�1--F-1--1-F1••1•-1-1--1--1-1-��1--1-f-1-�1-•Ir•1--1--1-1-•1--f-1--1-1-1--1--1-4-I•••f-f•-�i-1--�1-1--�1-1-�1-1-1--1-8--' • • • • • • • • 1--F-F-� BUILDER � � �_ COMPANY �� T - �c���'� !�f"'�C SIGNATURE '`� REGISTERED Y/ N FEE CURRE� Y/N Address ����ra� 7�C��CO/�'� �r' )/s'� C ��C.��q�G� � License# ELECTRICIAN �f� COMPANY �� MOr��p� ��'��`�r� � SIGNATURE �•� REGISTERED Y/ N FEE CURRE� Y 7 N Address 1 v� � 51�� 1��� /'s��G M �- License# ������ �� PLUMBER � � COMPANY l.��/'�I1 �/��T� ll ��B"�S SIGNATURE �� REGISTERED Y/ N FEE CURRE� Y .N Address � '�'l y� �� �� c �v f� �L License# V�� ��.���/�- MECHANICAL �� COMPANY �I�D r�ss i �� �1 i r~�y s-}-Cm f SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Address 5��`� c=5i7���f• �C,r�-r�f C�'r License# l.� C.� � OTHER ��-�.��,_ COMPANY l,/ 1 ��Crr'� ��CM- 1 n SIGNATURE REGISTERED Y/ N FEE CURRE� Y f N Address (B 7� f �`��' �7�` ���rs �" License# � �.;� � � � 1111111111111111111111111111111111111111111111111111111111� 111111111 RESIDENTIAL Attach (2) Plot Plans; (2)sets of Building Plans; (1)set of Energy Forms; R-O-W Permit for new construction,; Minimum ten (10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2),complete,sets of Building Plans plus a Life Safety Page; (1)set of Energy Forms:R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,$tormwater Plans vJ/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for a!i new projects.All commercial requirements must mee4 compliance SIGN PERMIT Attach (2)sets of Engineered Plans. *"**PROPERTY SURVEY required for all NEW construction. '�:--:-�E.i�-1..1..1�6..1..4.f-1..1-1-.1..1-'.�--^'�:-1-1..1.-1--i-a-1-.�--4-1--1-�f..1.-1�1..�1-1..1-�1-.i.�l-�I.-��• • • • • • • 1..�1-1--1.. Directions: Fill out application completely. ' � � , ; Owner&Contractor sign back of application;notarized ' . �`• _ � ' �, � �� If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ** Ageht(for the contractor)or Ppwer of Attorney(for the owner)would be someone with notarized letter from owner authorizing�same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) ' Driveways-Not over Counter if on public roadways..needs,ROW '' ' � , , NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed res�rictions. � UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed.in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for�a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, �s the owner sign as the contractor, that may be an indication that he is not proper•ly licensed and is not entitled to permitting privileges in Pasco County: , • � � I TRANSPORTATION IMPACT/UTILITIES IMPACT�,ND RESOURCE RECOVERY FEE�: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of _ use in existing buildings, or expansion of existing.buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended, The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource.Recove•ry. Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furtherrnore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. � ` CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable. laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that rio work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development�regulations in the jurisdiction. I also certify that I understand that the regulations of other�government agencies may apply to the intended work, and that it is my responsibility'to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. � - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering WatercQurses. - Army Cprps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. • - US Environmental Protection Agency-Asbestos abatement. , - Federal"Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is'not allowed in Flood Zone"V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compelisating volume" virill be submitted at time of permitting which is prepared by a professional engineer licensed;by the State of Florida. � - If the fijj�material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will. not adversely affect adjacent S':. properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) , acre whlch are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to�commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall k�e construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit preyent the Building Official frorri thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the worl< authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY: IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR L�NDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S. 117.03 � ^`� _. �Q � OWNER OR AGENT �"°�� CONTRACTOR �/�°"� � �Subsc ibed and sw4�to;(or affirmed)before me this Subs ibed.and sworn to(or a irmed) efore me this y .iJ C��r n-c'����st..ti cI.1,c 0 � , by ��c r+.n c_�L +���r l�c�,,•.� , � Who is/are personally known to me or haslhave produced Wh is/a e personally known to me or has/have produced as identification. as ide�Iification. �' Notar Public � ' Notary Public Y _ Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary t ped,printed or stamped I Y Pu Plotary Public State of Florida o'�9aY�'eG Notary Public State of Florida ?°��; Gail M Donahue o C� : Gail M Donahue � My Commission FF 170472 9 �oa My Commission FF 170472 ��FOF�,o� Expires 11118/2018 �°oF p.a Expires 11/18/2018 '( J 04-26-21-0070-00100-0220 � Pasco County Property Appraiser Page 1 of 1 � "" �� �� Data Current as Of: Weekly Archive - Saturday, April 15, 2017 Parcel ID 04-26-21-0070-00100-0220 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value DUNE FL LAND I SUB LLC Ag Land $0 C/O HAWK MANAGEMENT CO LLC Land $25,550 2502 N ROCKY POINT DR STE 1050 Building $0 ROCKY POINT FL 33607-5995 Extra Features $0 _ Physical Address 36173 STABLE WILK AVE ZEPHYRHILLS, FL 33541 .7ust Value $25,550 Assessed (Non-School Amendment 1) $25,550 Legal Description (First 4 Lines) SILVERADO RANCH SUBDIVISION PHASES 2, 3 &4 PB 73 PG 059 Taxable Value $25,550 BLOCK 1 LOT 22 ]urisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line _ �Use _��Description;Zoning_�U_nit p Price 'Condition�lue �---- --_�._____._.— 1^ 0100 SFR`_i MPUD 6,000.00 SF $4.25 ( 1.00 $25,500 2 � 0100 �� SFR � MPUD � 150.00 � SF $0.33 � 1.00 $50 Additional Land Information _.__.4________._--�-- F E MA �-- Acres 0.14 ` Tax Area i 30SI ���Code '- �Residential Codel SLVRLPI --..._� _�_� --------_ Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) -�------ ------��_ ___�— Line T�_�_ iDescription �Year � rUnits Value '_ _ No Extra Features Sales Histor�- See All 5 sales Previous Owner: Month/Year Book/Page jType �;DOR Code �Condition lAmount �^ --+------ ------�t A09/2011 �i 8606 / 3376 _ '� Warranty Deed ( 05 �� Vacant _� Multi-Parcel Sale� � 12 � � Vacant 0� � 05/2010 8373 / 1912 Certificate of Title 1 — ---� _. � ---- $ 07/2005 W�� 6725 / 1059 fi Quit Claim Deed 1 ;�Vacant � $0 http://search.pascopa.com/parcel.aspx?sec=04&twn=26&rng=21&sbb=0070&b11�00100... 4/20/2017 � 36173 Stable Wilk Ave-DR Horton Inc:2,238 sq ft single family o umn SQ. FEET PRICE MAIN OR LIVING: 2,238 $ 101.90 OTHER AREA UNDER ROOF: - $ 88:00 , OTHER: - $ - VALUATION $ 228,052.20 , I FEE SHEET $ 875.00 � ADDRESS $ 40.00 DRIVEWAY $ 40.00 � BUILDING: $ 972.50 ELECTRICAL: $ 196.88 �I � PLUMBING: $ 131.25 MECHANICAL: $ 91.88 �� SUB-TOTAL $ 1,392.50 I TOTAL $ 1,392.50 � SEW ER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: $ - n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 1,945.85 PARK IMPACT FEES $ 769.56 � SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 . T'I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,223.69 36173 Stable Wilks Ave o umn SQ. FEET PRICE UNDER ROOF• 2,238 $ 101.90 OTHER: - $ - VALUATION $ 228,052.20 FEE SHEET $ 875.00 ADDRESS $ 40.00 � DRIVEWAY $ 40.00 BUILDING: $ 972.50 ELECTRICAL: $ 196.88 PLUMBING: $ � 131.25 MECHANICAL: $ 91.88 SUB-TOTAL $ 1,392.50 TOTAL $ 1,392.50 SEWER: WATER: IRRIGATION: $ - TOTAL: $ � - WATER METER: IRRIGATION METER $ - �FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 1,945.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ " 36.32 , TOTAL: $ 11,223.69 , Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. , 4. Tie in survey required before pouring concrete. ' 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have , expansion material. ' 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. � 9. No electric,plumbing,mechanical, or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. , 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. ' 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating � or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. A112008 N.E.C. Codes will be enforced. 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 22. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 5�'Edition , R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008) , f � --_.�_---_-__ __- "- � CITY OF / / / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION � • • - • qp � DATE PERMIT�, �3 S�� �� �l�� L ����s� � ����r� THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. �� It is unlawFul for any carpenter,contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE- SPECTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30 AM-5 PM MON.-FRI. INSPECTOR PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 22, BLOCK 1, SILVERADO RANCH SUBDIVISION PHASE 2, 3 & 4 - AS RECORDED IN PLAT BOOK 73, PAGE(S) 59-65, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. PC /. � � rn � J�� �`! N/� Z � 3� ��. = 30' � / GRAPHIC SCALE Q ti N�� �� 0 15 30 JC � c� ��� 3QOp�W �/� � �� y$$a �Q�' S-���r��Q / ��,,,; e�� 23 � Q .��; �k 1 � � / '„r.,'��"„�, ?)3• � ���U2+ 6 / �.�3� / �4��c 99 � � / .� '� � \ � � ;\s; �k� 2�� o ;w ���4g.\ ��1.46, / v 'r::• �..... s �s• �• �� �o , _ � �,�.:;%��^ ' Y. . / ��. 8s�' � o ''°o � �c '2;:' .i=;_. C O :i:'�:fikr% ��.i:f::i..�. ::' ;:: 'i� �. 0' .�Q m�u;ul� �r.�.�::: ,,`, '?+i� .,;i��:Y»,r r::. '� I tl' a:8,� \` � �u �o �r:i�.� . t.y' %�a.>.�/,,;;'r.'�;;�t'-�• ?p•'• o,. 2'; y !� Q (�� ?S.';.. '.�' � .a � (SA �Y.� '��ni� :s"�, �:�'I-�ip. �p� Q . �p/ ,5. n�x�cs:� 'ot:{l��r��;-!' � p A��O ^,.xa�:N 3z4. C� a e� � C� ' '„lX.i;�:?�,�,.;::""' .�i�- o„'�m�'d ''�-= � Q' o ,4'2 ,;:s =,•.r�.�..�;..j �'v o,Cr a��e�o •, e.o• ^ � �oa '�. �,,j t.. o�? ���Q M �V �H�� ��c 23e N •� � /� V�i�� 4 Jp4 y 47 � � �y��� g9 O i�- � N /�� \ ��, n �J"'2a �u L� Q�"a/ �Cf� / �V�'•n �.� N ��Q� \ _ / J2 44"�'V \ ���A�` � \ � � ,,2 �� � \'331 � ' � ��T O ^ • p� e���K � ,o`° � c� � o0 ��� / i PREPARED FOR: LEGEND: Il•H�HO}37iiN�� ON LOT CALCULATIONS - - - BUILDING SETBACK LINE ��:� tY.����'�, LOT = 6,150 SQ. FT. - -- CENTERUNE `�j° LIVING AREA = 1,672 SQ. FT. GARAGE = 432 SQ. FT. — RIGH7 OF WAY uNE BUILDING SETBACKS ENTRY = 38 SQ. FT. � PROPOSED ELEVAltON FRONT: 20� LANAI = 96 SQ. FT. � pROPOSED DRAINAGE FLOW REAR: 15' PAT10 = 0 SQ. FT. SIDE: 7.5' DRIVEWAY = 341 SQ. FT. � CONCRE7E SIDE STREET: 20' A/C PAD = 12 SQ. FT. n/c AIR CONDITIONER � WALKWAY = 28 SQ. FT. s/W sioexa�x NOTES: IMPERVIOUS = 43% PI POINT OF INTERSECTION 1. ELEVATIONS SHOWN ARE PER LOT GRADING = 2619 SQ. FT Pc POINT oF CURVATURE SOD = 3,531 SQ. F.T. PT POINT OF TANGENCY PLANS PROVIDED BY THE CLIENT RP Raolus POINT 2. ELEVATIONS ARE BASED ON NAVD 1988 OFF LOT CALCULATIONS PRC POINT OF REVERSE CURVATURE RIGHT OF WAY = 990 SQ. FT. PCC POINT OF COMPOUND CURVATURE DATUM. DRIVE APRON = 228 SQ. FT. � �ICnL CS CONCRETE SLAB PUBLIC S/W = 275 SQ. FT. (p) PER PLAT THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES SOD = 487 SQ. FT. (c) cucuv,�o ONLY. THIS IS NOT INTENDED FOR iHE CONSTRUCTION OF 7oTALS 7HE PROPOSED HOUSE. REFER TO HOUSE PLAN AND pGs P GES OOK OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK AREA = 7,140 SQ. FT. S�. FT. SOUARE FEE7 LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT DRIVEWAY = 569 SQ. FT. F.E.M.a FEDERAL EMERGENCY MANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY SIDEWALK = 303 SQ. FT. F.I.R.M. FLOOD INSURANCE RA7E MAP NAVD NORTH AMERICAN VEF2TICAL DATUM THIS IS NOT A SURVEY SOD = 4,018 SQ. FT. D&UE DRAINAGE& UTILIT'E SEMENi AnM THIS IS A PLOT PLAN ONLY auE PUBLIC UTILITY EASEMENTENT FLOOD NOTE: SURVEYOR NOTES: I HAVE EXAMINED 1HE F.I.R.M. COMMUNIN MAP N0. 12101CO228F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE DAiED 09-26-14, AND FOUND THE SUBJECT PROPERTY APPEARS TO LAND SHOWN HEREON FOR EASEMENTS, RIGHT LIE IN ZONE X, AREA OUTSIDE THE 100 YEAR FLOOD PLAIN. 7HE OF WAY, RESTRICTIONS OF RECORD WHICH SURVEYOR MAKES NO GUARANTEES AS TO THE ABOVE INFORMATION. MAY AFFECT THE TITLE OR USE OF THE LAND. PLEASE.CONTACT THE LOCAL F.E.M.A AGENT FOR VERIFlCATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF STABLE 3. NOT VALID WITHOUT THE SIGNATURE AND WILK AVENUE BEING N18'07'is�e, P� au�T. " THE ORIGINAL RAISED SEAL OF A FLORIDA (FIELD DATE:) REVISED: A M E R I C A N LICENSED SURVEYOR AND MAPPER. SCALE: ��= 30 FEET � U R �/E Y I N G �B 8cM APPING INC. . npPRoveoar CERTIFlCATION OF AUiHORIZATION NUMBER LBy6393 FOR 160972 LO7 22, BLOCK 1 3191 MAGUIRE BOULEVARD, SUITE 200 h{E �os No. ORLANDO, FLORIDA 32803 Flau (407) 426-7979 DRAWNBY: DSB pLOT PLAN 11 72 ts CF �•AMERICANSURVEYINGANDA�APPING.COM JAMES W. BOLEMAN PSM# 6485 �A�