Loading...
HomeMy WebLinkAbout17-18394 CITY OF ZEPHYRHILLS 5335-8TH STREET (sis)�so-oozo 18394 ; BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:18394 Issued: 4/28/2017 Address: 6528 PADEN WHEEL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 342,230.70 Total Fees: 11,736.69 Subdivision: SILVERADO Amount Paid: 11,736.69 Date Paid: 4/28/2017 Parcel Number: 05-26-21-0070-00300-0100 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 15550 LIGHTWAVE DR Address: 4600 W. CYPRESS ST STE 200 CLEARWATER, FL. 33760 TAMPA, FL. 33607 � Phone: (727)479-1740 Lic: Phone: (813)574-5700 Work Desc: CONSTRUCT SINGLE FAMILY HOME 3,038 SQ FT APPLICATION FEES BUILD G FEE 1,321.33 ELECTRICAL FEE 273.83 PLUMBING FEE 182.55 MECHANICAL FEE 127.79 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfd100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 1� ��,,"-ce.�� �/ Rec�✓ �- �� � � � ` � � � cl�-� �a�'S� � ' Ins ections Re uired FOOTER 2ND ROUGH PL MB MIS INS LATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. � 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER` MISC DRIVEWAY , PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this properly that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for ��I improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be pertormed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACT S SIGNATURE PERMIT OFFI PE MIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER � ' PASCO COUNTY BUILDING CONSTRUCTION SERVICES ��, 8731 Citizens Drive Date:6/1/2017 Suite 230 - '�� New Port Richey,FL 34654 �. . 727-847-8127 ** NaT A PERMIT ** Record#: 06POS-00000�#0000 Recei�t# Paid Check# CC Auth# Cashier ID Workstation Receiat Date Amt Paid 9683366 Check 864400 294 BCCCP38W 06/01/2017 $37.40 Total Payments: $37.40 Pavor Address Phone LENNAR HOMES LLC Comments• 6528 PADEN WHEEL ST ZHILLS,FL. 0526210070003000100 PERMIT 18394 ` } � ,.....:,.:..;:,.;::...:................:. . ..... ...,. ....:..., _- - - - - - - - - - . ... .. . -,.:,-:...:...,-.,.,.�::..... ... ....:.._..-.. ,_...,�::,. „-�.,:._......,�.,� , . ,:.- ,._ .._, .�... :...__,..�_. ..�..:::,;.,,_ -=�-=>; _ _ <. , ,.. _ - - -,::-_,._. .. .. . ....._ . ,..:.-. ...... _<...,..,:._ � - - _..-:;:.,.,•,,.�.>:--..,,:,;.,,.�...:.: _ . . ....:���=�:�... :S: ..-..._. .:.:::,..:,-�...�. ....._r ' .. .., ./. .r'., '.....i. ...f.:�:^ . �.�.. . ...� . _.��.. ' .._ ...�..:._-..�........ — - �'��1N - .. ._ �.. � ,iPMor anfChase:Bank-.N.A.:�,> _ :-ST;UB=�;';�L'HECK:NO; - 0289585b..Lennar.�Tomes.LLC_,-.:,�,.:,.....�.... ,_, --. 9 - - _- ,.. , .._.�..,.�_.;:�,_. �.....:. ......._ - - _ . .:_. , . :. _._:.. ..-. - - __.... _ . . . _,. ..�.. ��:.,...>:;..::�" - .,. . �... . .n .. .............. . .. .. ... . __... . 1 �.,.... - :�>"� �.> - - _ _ -- _ -_ - __ - __ ss,. _ �1:=�;�;:;''�:I1ATE;'0 /25J1`7�:;:-'�;:��L•:�:L';'' ,,.:.,_-.., . . ; ,a..:.194::;��::-,�:::'�`:;`.:;:�;.%�'-;:=�:<:_:=--;.:;;:">>�j,,o£: .....;...• ,.. . _. ,.. .:;_. .. .:.,-:.�._....;.:.� ..: ;;,:;,.>.;:..,-;:._. ,.:: - �,,.�, . ;:` _ - _ ::le . ,. � c-�=i�,. ,,. . ..�..._._. _ . ..:?; - - _ _ :=;9000G0:1D.0. , . . ,INY I :�_._• � - ..,:.. .:.;,._...,._ ..., . p�;=;.;:• - - .,...:<:.., , ,;��, . _ .,:. ,.:;�,,.,:,;. ,.,.;.:,.�:..,.. - - - - -- - . :-.:> :, "'-;,=: r..;,. '. `,._: .. .......... ....._... .... .. - - _, .. ,�:.. . ., .._ _ ... . . .,._�.. ..:.,. ......... _� � :..;': .. - .:.:- . >:. ...._.., -- - - - ,... ..:._..... ;,;_. ....__ . .... .. . .. .. .. : ...:CO.:#.•;...'::�..;,:;':>;NUMBER:<�,:,:-:.:;.. :•:: .irDATE:.•::..:........ . ;-::;,_...PAY11fENTi1DVJCE-:s7::�`.:�.. ..::''=:;5..:. c,`i'r�:GROSS.�:::.;.:r! ;':;�='DISCOUNT...:�--<;,.,. . ..NET:: ': - . ,.,. ��. :::...._ .,:;,:�,..,::n,-;:�:- - - - _�...�;... . .... , �<.-i .,.... . ..-..,, �. ,,.....�. .,.�.,.,.....,c� .:::;:�� -- - - ... ,... ..... . ::.....n...� ...� , .. . .. . _.� � ... __. . .�,.�:. . _ , , r::�,...,:'::�n..;i.. ,. ., . - .._. , .� .,. ,, :. .:.:....... . ._ . . .. r. .Y .. . . .� ... ,._ ....., . _..;.: . ..... ..-�' ...,.. .�:.�. :.. t��.i.: . . . . _ .. . . r.... ..... ..... . . . .. .. :....�. ....<, .,_.,-... ,. ' - ' .i.+ ,.._...,. d .. , , . . . . ._ .{...:t�.:. �^;. ..:i:"'�..':'...,:� ::rJ. ...J., :............ ..,.,.:.. .:t....r.. ..,. ... ... ..... ... . .� , ....; .. j:i.+ . .. . .^: .. : � ..:._..�:i. .:� .. •...�; �. . .... � , " . - _ _ _ '::��::':.'�':i:'''..:�..�:':.:.':��;:..�t,:.:.�:: . ...�. �.... . .. . .� _.1 22 1040 435_:, ....,.::,.;.:.�:�: :: � ,......,,:..,_: ..�.,,r.;.._,::r�t�s.$37:40:':.:",';`;<"i�s.,.. ..,.s:.-$0:00:: ;r..,•lra:;�$37t�10::; .:; �15225 . 15225710310.401435;:•� -051717. 5 57103 1. �/' S _ ::t: :rf �_,..�• [:j:�.�. - ' ` .. .�. '... •. � . . ... . -.� :�� _ :,� .i .i, ..: ':�. ::.• '���' .... .. .. . ' .^ . .'. ".i. . .,. ..y. . . ... . ��:'.'..::.`�:=.:.�:Li.�.... � ,_. ,,..�:. '. ... ., ... .. ,.� + ; ,�.� . a .... . �. �..........:v..��. .v:: •:::.'. 'i' :�':'i. �' , ..... �.u�.'._.r...... .... . .... .::.... . i. .... �._. . ...... .� . . .:i:. ..:�. 'f�. .. ....i.l..... ,... ..�..i..i....�. . . . . . . ._.. ,_.. ... ... ... - t� .. . . .. .. .. .. . . .... . .. i ... > .i .. . �.':: .:-�'.�.:� _ >'j.': , _..%"::'��::'.�i - ':.:..eii. ........... ..� .. ..._.............. .... ..... .... ....... ... - _ �t: ;.� ..�.r,.. .i..�, . ..... �:T.'. -_ - _ _ _ _� _ _ _ i.::.y.... :i:[.. . .:.,.^'._ -,n. ." "..:...:4i:�J:�(.�. .�..�y:i:'::. �� � .. _ . ' - . � - . ' - ' _ - ._ .l'. . . _ _ _ _ _ -_ - 'J:�;.�:.,. - - ''L:'='.'�:.';,�-';^•:' - ' - - ,.l:.�i�.'.:�'."i: .i'.�:r_. _ i ' ''./.:'..' .:S ��71. - l . ....... ..: .��... ._ . " _ _ _ _ ' - -. . . '_.j�' ' ..�.... ..i t ,. r.�.,_ .... . . �.. ::: _ - _ _ �_.. e.. i �.:i: � .. . � .. ...:. , . . _ , _ .. , . , . ... .'J::•::. ' .. . ' � ' _" " ., .. - _ _ _ _ - ...h., n.. _ _ - ' . . ' .. '. .. - . 'r.7!, ' - '_ .:, ., , . ' � • . � - :7; - -' � - � .. ' ''�: .. .,. ., r ., -_._ ' ' - ,_., .. .,...,.�. . ::. . .._• ., ., _ •:��' .. . : ;. . ...�...: • - � ..,,;...; . :: • : .:�;.. ....: .:,, . �... � �::. ::. � . . s- . . ._. .. -,;,� : . , - . . .�..;:.��,. � ,.. .:�: ...� ,. ,.:.�r _ . .. - �r_' �J`' , 1� - . �.J . . . - .. . " �;v. . - . - .. - .t� �. ' . •�\:'���'. " . . �,� . . . . . . � ' . . .� ) . . . ' . � • � . . ." r . _ . � - �'\ i . . . , . - - =7 .. . ; ,^ . _ . .... ' •- " ' � • . .. . . � ,. . - ..' . ,:� ; .... .: r.� . _ ' .y _ _ ., ... .. '.�::�. .. � ' .' '., , . _ . .. _. '.;."c - ' " .. _ " ' ."!� . . -" - .. .. ' _, ... .,. � .. � ., , :_. .:.� . ... ._ . " .. .. " . .. 7:r. h r . ..... ,,r��;> , . .. .�-. �� I -. ,�, , _ ,. .:,'' � , , _ �.1'.�' •- ' ,I - .. . . . - . - -�' . - :. -' :7� .. :i� ' - - '� ' . .. . ., ' _.. I .. " " _ . ... . . . , . . ,I7 .. �, . . - _. . _ , . . .•... .....��..... . :.. ... . ....._........ . .. ._.. .. .. . . ... .... ... .. ....:.... ........ ...,...., � . ..... . . ......... . ' 1971597 Pasco Couriry BOCC .. '.,'" _ ".:; .7530 Little Roa ::°�:..:... '=-:;-:;. , . . , - �,y" _ _ , , .. :: . ...:.... ' -- �• PortRicheYFL33553=0000 `. .. . � , .:....-.=`." .'" $37.40�.: : . ....:..::'. .$0.00' .. `-'$37.40. : . . . . . . .. ... , . . . I MyReports/reports//PRODUCTION/PASCO/ReceiptAA 6/7/2017 Page 2 of 2 � o �Q '!(1�,��AtltN., '^'�V r?`E,'1'-�'1r;«.+'. . � �'�'�-:.•�� ' ",hy y , City af Zephyrhills BUILDING PLAN REVIEW COl��NIENTS Cantractor/Homeowner: �� �7��"�'�'- Date Received: , �-��!' Site: CC/�� ,�`'�,C-�"�°`2 G�l����� Pennit Type: � ��� `�� ��-U Approved wlno comments:❑ Approved wtthe below comme�ts:� Denied wlthe below comments: O Yyy This comme heet all be ept with the permit and/or plans. ,J ; ���1`l� f Kalvin Switzer—P s xaminer Date Cantracto and/or Homeowner (Requir when comments are present} ' �� ' � � � „ , � \ i i �- 1 CITY OF / / / / BUILDING � ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION � � • • - • � , ADDRESS e DATE PERMIT�, � �s��� .����'� ���e�l � ��7" THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shcll be made before the job will be accepted. <, � � P � A I � It is unlawtul tor any Carpenter,contractar,Bui�der,or other persons,to AFTER CORRECTIONS ARE MAD cover o�cause to be covered,any part of the work with flooring,lath,earth 7$�-�02� F RE-INS EeTI or other material,until the proper inspector has had ample time to approve the installation. OFFIC�HOURS 7:30 AM-5 PM MON.-FRI. INSPECTOR �,\ � � ;' i � � ,1 . 1 ' � _ - �����i����i����ii�i�«���i�i��i�i���a ii�«i���c����i i�iri�i� 2017061378 ' f Rcpt:185?470 Rec: 10.00 \ D5: 0.00 IT: 0.00 - @41251201? C. F. , DPty Clerk PRU�A 5 4'NEIL,Ph D PA5G4 CLERK & COMPTRO�I,ER 040R BK �����m PG ���i r Permit No. Parcel ID No 05-26-21-0070-00300-0100 NOTICE OF COMMENCEMENT State of Fiorida County oi Pasco - TFiE UNDERS{GNED hereby gives notice that improvement wi!!be made to certain real property,and in accordance with Chapter 713,Floride Statules, the following infotmation is provided in this Notice of Gammencemenf: 1 Description of Property� Legal SILVERADO RANCH SUBDIVISION PHASES 2 3 &4 PB 73 PG 59 BLOCK 03 LOT 10 � sf�e�tAadress: 6�28 Paden Wheel Streefi Zepf�ryhills FL 33541 2. Generat Description ot fmprovement �ingle Family Residence/Poal/Screen Enclasure/Fence 3. dwner Informafion: �-��nar Hames,LLC Name 4600 W C�press St. StP,200 Tampa FL 33607 Addcess City State Interest in Property� Name of Fee Simple Titleholder: N�A (if other than owner) AddTess City State 4. contractor: Lennar Nomes LLC Name 4600 W Cypress St Ste 240 � _ Tampa Fl_�33607 Address City State Contractor's 7elephone No.. 813.574 570p 5. surety� ... . N/A Name Address Cify State Amount of Bond: $ Telephone No. s. �ender� N�A Name Address Cify Sfate Lender's Telephone No. 7 Persons within fhe State of Florida designated by the owner upon wtiom notices or other documenfs may be served as provided by Sectian 713.13(1)(a)(7),Florida Statutes: ' Lennar Homes LL�� Name 4600 W Cv�ress St Ste 200 Tampa FL� 33607 Address Cify S#ate Telephone Number of Designated Person: $13.574 570Q e. In addition to himse(f,the owner designates N/A of to receive a copy of the Lienor's Nolice as pravided in Section 713.13(1)(b),Flarida Statules. Tetephone Number of Person or Entity Des'sgnated by Owner� 9. Expirafion date of Notice of Commencement is one year from fhe date of recarding unless a differenk date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMEN7S UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, ANC1 CAN " RESULT IN YOUFt PAYING TWtCE FOR IMPROVEMENTS T4 YOUR PROPEFtTY. A NOTICE_OF CONiMENCEi+lIENT MUST BE RECORDED AIVD PCfSTED OfV THE JOB SITE BEFC7RE THE FIRSI'INSPEGTtON, t�YOU INTEND TO OBTAltV FINANCING,GONSULT . WITH YOUF2 LENDER OR AN ATT�dRNEY BEFORE COMMENCING WORK OR RECpRDING YOUR NOTICE OF CCIMMENCEMEN7, STATE OF Fl.Oft1DA �'� COUN7Y OF PINELLAS • Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this �� day of MarCF1 ��t 1 ,by S18V8 S(Tilth as Vice Pfesfdent � (type of authority,e.g.,officer,trustee,attomey in fact)for Lennar Homes �LC ,e of p on b whom instrumentwas executed). Personally Known�OR Produced tdentificatian❑ Notary S' nature Type of Identification Produced Name(Print) E�1SS� �@l'c']fl Ver'sficafion pursuant to Secfion 82.525,Florida S(afufes. Under penalties of perjury,1 declare that i have read the faregoing and fhat the fac#s stated in it are true to the best of my knowfedge and belief. c�-�"-----� 'j� "'� _ECISSAhf.HOLIERAN Signature of Natural Person Signing Above - ��; �;�C�mmbsloo�FF 88589'T �"?F�i�lrea June 8,2020 wpdata/bcs/bcs form; .�'!�„�`"'� �ndetThruTmyFainiMunncal00a0.5-701p . ��,��,��� � ��� m�� �� � ���a z � !o �s� ry��,¢_��- � �„ � � �v���'� � �' �'`�� „'?trf'� ' � 4� �4' _ ' ` �� Q'PfF�j \:3'� •o•� _— �— _ __ ���a 9 � i �. ������� � � STAT�OF F�CD�IDA, COU�lTI(OF PASCO THIS IS TO CER i iFY THAT THE FOREGOING IS A TRUE AND CORRECT COPY OF THE DOCUMENT ON FILE OR OF PUBLIC RECORD IN TNIS OFFICE WIT Y HAND AND ICIAL S L THIS DAY�F / 2C��� PA S. O' IL, C & O TROLLE � gY -- DEPUTY CLERK • � 6528 Paden Wheel St-�ennar Homes LLC single family home 3,038 sp ft u S�.FEEf PRICE MAIN OR LIViNG: 3,038 $ 112.65 O i HER AREA llNbER RdOF: - $ 88.00 � OTHER: - � - VALUATION $ 342,230.70 , FEE SHEET $ '1,217.00 ADDRESS S 40.00 DRIVEWAY $ �10.00 BUILDING: 5 1,321.34 ELECTRICAL: S 273.83 PLUMBING: $ 982.55 MECHANICAL: 5 127.79 SUB-T�TAL $ 1.905.50 TOTAL $ 1,905.50 SEWEFL: n/a WATER: n/a IRRIGATION: S - TpTAL: $ - WATER METER: $ - nla IRRIGATIOht METER 5 - FIRE DEPARTMENT FE�S PLANS TdTAL: Na tNSPECTION TOTAL: PERMl7 70TAL TOTAL: $ - PUBLIC SAFETY 1MPAC7 FEES POLfCE $ 254.00 _ FIRE $ 273.00 5% $ 26.35 TQTAL: S 553,35 SUB-TOTAL $ 2,458.85 PARK IMPACT FEES $ 769.58 51F'S: $ 4.828.p0 ,00:�; $ d.84828 �j{.,s I "+y �Mi ��5 g S, � ! TOTAL: S 4,87828 �j� J � � ��,�D T I F'S: $ 3,632.00 �'..{/5,2� 99°k $ 3.595.68 ✓' ,.. 7% �i 36.32 TOTAL: $ 19,736.69 . � i i � �A5C0 CQllfVl'Y; �LORIDi4 � , Permit No. Date Permitted Builder Name/Owner Name � ��� ��i �ar �� Control# County Parcal No. D�,7�.�,� ��7� ����0 ���y� -,d�LY�SubDlv: 1 Address/Location ��2� �q�Pe� /�� < f� Classificationll'ype of Use ��'�� l� " r TRANSPORTATION I�VIPACT�FEE , Rate: , ' Sq.Ft Unit: ,3 `3 • Exempt � Yes [] No How Determined Impact Fee Amount _$ 3,��,Z,� � Zone Nb. ___ TqZ: I SCHOOL IMPACT FEE �— Account (056) Single-Family Detached House Amaunt (057) Mobile Home $ �76•Z{, (058) Other Residential " �123) Collection Fee Exempt Yes Q No � How'Determfned PARKS AND RECREATION FEE Land Account Land Cred(t ' 'Land Total � . � •Recreation Account �_ Recreation Credit - __ Recreation Total _T_ - Zone - -- • TOTAL AMOUNT $ 76 , � Exempt [] Yes [] No How Determined � • LIBRARY FEE � Land Account Land Credit Land Total ' Facility Account �_ Facility Credit - Facility Total � Exempt � Yes � No How peterm(ned - �_ Total Amoun RESOURCE FEE • TOTAL-AMOUNT ERU Prepared By . Checked By �` i. NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION � PERFORMED UNTIL THE TOTAL AMQUNTS LISTED HAVE ' BEEN PAID ANp ; RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY 'j Acknowledgement below does not Imply acceptance of concurrence;but slmply recelpt of a copy of thls form, Iaqing the bullding permit owner on nodce of this assessment and thq condidons of payment for same. � DATE � I RECEIVED BY RECEIPT NO. �_ pATE ___i BY i ' . . . 'I � \ ., s . FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2268 sf ADS Builder Name: LENNAR HOMES street: 6528 Paden Wheel Street Pe������ Cl of Zephyrhills City,State,Zip. ,FL, Pertnit Number c� Owner LENNAR HOMES Jurisdiction: C1�( Q3 � Design Location: FL,Tampa 1 New construction or existing New(From Plans) 9. Wall Types(2268.0 sqft.) Insulation Area 2. Single family or multiple family Single-family - a.Concrete Block-Int Insul,Exterior R=4 1 1904.00 ftZ b.Frame-Wood,Adjacent R=11.0 364.00 ft' 3. Number of units,if multiple family 1 c.N/A R= ft' 4. Number of Bedrooms 4 d.N/A R= ft' 10.Ceiling Types (2267.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2267.00 ftZ 6. Conditioned floor area above grade(ft2) 2267 b.N/A R= ft' ' Conditioned floor area below grade(ftZ) 0 c.N/A R= ft' 11 Ducts R ftZ 7. Windows(277.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 600 a. U-Factor: Dbl,U=0.54 143.00 ft' _ SHGC: SHGC=0.31 i ` b. U-Factor Dbl,U=0.58 96.00 ft2 12•Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.20 c. U-Factor• Dbl,U=0.56 38.00 ft= _ SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency i d. U-Factor N/A ftZ a.Electric Heat Pump 32.8 HSPF:8.70 � SHGC: Area Weighted Average Overhang Depth. 4.206 ft. Area Weighted Average SHGC: 0.309 14 Hot water systems 8. Floor Types (2267.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 2267.00 ftz b. Conservation features b.N/A R= ft2 None c.N/A R= ftZ 15.Credits Pstat Total Proposed Modified Loads: 71.00 pASS Glass/Floor Area. 0.122 Total Baseline Loads: 72.50 I hereby certify that the plans and specifications covered by Review of the plans and �'��s�'��, this calculation are in compliance with the Florida Energy specifications covered by this �,� �� r"_.�.��0�,, . Code. calculation indicates compliance �'�r,,,;'' "_:=�'��`. � ,{/,,� /. with the Florida Energy Code. �+ ?rr�r,�'.%r;;`;�'�;�.,��;,,��O. PREPARED BY. �av� r�fWl{'I�VG Before construction is completed w ��E` '' - " � DATE. this building will be inspected for i�,ry ���.��';` " ;��� ' compliance with Section 553.908 * �"� - I hereby certify that this building,as designed, is in compliance Florida Statutes. �,� ",. � ���� i with the Florida Energy Code. � ��U�Wfl`� � OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct�leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. 3/17/2017 7�48 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 � s . FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method - Project Name: 2268 sf ADS Builder Name: LENNAR HOMES � street: 6528 Paden Wheel Street Pe��t off�� City of Zephyrhills City,State,Zip: ,FL, Pertnit Number� Owner• LENNAR HOMES Jurisdiction: 611600 Design Location: FL,Tampa 1 New construction or existing _ New(From Plans) 9. Wall Types(2268.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1904.00 ft' b.Frame-Wood,Adjacent R=11.0 364.00 ft' 3: Number of units,if multiple family 1 c.N/A R= ft' 4. Number of Bedrooms 4 d.N/A R= ft' 5. Is this a worst case? Yes �0.Ceiling Types (2267.0 sqft.) Insulation Area Z a.Under Attic(Vented) R=30.0 2267.00 ft 6. Conditioned floor area above grade(ftZ) 2267 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ 11.Ducts R ft' 7. Windows(277.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 600 a. U-Factor Dbl,U=0.54 143.00 ftZ � SHGC: SHGC=0.31 b. U-Factor Dbl,U=0.58 96.00 ft' 12•Cooling systems kBtulhr E�ciency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.20 c. U-Factor• Dbl,U=0.56 38.00 ftZ SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor• N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.70 SHGC: Area Weighted Average Overhang Depth. 4.206 ft. Area Weighted Average SHGC: �.309 14 Hot water systems 8. Floor Types (2267.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF.0.950 a.Slab-On-Grade Edge Insulation R=0.0 2267.00 ft2 b. Conservation features b.N/A R= ft' None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.122 Total Proposed Modified Loads: 71.00 PASS Total Baseline Loads: 72.50 I hereby certify that the plans and specifications covered by Review of the plans and ��'T�:�T.��.� ` this calculation are in compliance with the Florida Energy specifications covered by this ti. , ,� p�,� Code. calculation indicates compliance �'��,�,�' "=�'��.�. .��„ ,{ /, with the Florida Energy Code. ��� ```""~'`��'�'`,� O. !-+. .rrrrrr: :�`.-,,•• PREPARED BY: �aVe rf����'l Before construction is completed w �• "�" � ��-��,��'.",r.�., • � DATE: this building will be inspected for �. �'I,:�`� ;a. _ compliance with Section 553.908 * ;� I hereby certify that this building,as designed, is in compliance Florida Statutes. ;r+�� . ��� ; with the Florida Energy Code. C�Zj;yy�,`T� OWNER/AGENT. BUILDING OFFICIAL. DATE: DATE. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as , certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed�duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. 3/17/2017 7�48 AM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4 � 5 . FORM R405-2014 '� FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION ' Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2268 sf ADS Builder Name: LENNAR HOMES street: 6528 Paden Wheel Street Permit ot�r.�: City of Zephyrhills City,State,Zip: ,FL, Permit Number� Owner• LENNAR HOMES Jurisdiction: 611600 Design Location: FL,Tampa 1. New construction or existing New(From Plans) 9. Wall Types(2268.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1904.00 ft' b.Frame-Wood,Adjacent R=11.0 364.00 ftZ 3. Number of units,if multiple family 1 c.N/A R= ft2 4 Number of Bedrooms 4 d.N/A R= ftZ 10.Ceiling Types (2267.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2267.00 ftz 6. Conditioned floor area above grade(ft2) 2267 b.N/A R= ft' Conditioned floor area below grade(ft2) 0 c.N/A R= ft' 11 Ducts R ft' 7 Windows(277.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 600 a. U-Factor Dbl,U=0.54 143.00 ftZ SHGC: SHGC=0.31 b. U-Factor Dbl,U=0.58 96.00 ft' 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.20 c. U-Factor Dbl,U=0.56 38.00 ftZ SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.70 SHGC: Area Weighted Average Overhang Depth: 4.206 ft. Area Weighted Average SHGC: 0.309 14 Hot water systems 8. Floor Types (2267.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF 0.950 a.Slab-On-Grade Edge Insulation R=0.0 2267.00 ftZ b. Conservation features b.N/A R= ftZ None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.122 Total Proposed Modified Loads: 71.00 pASS - Total Baseline Loads: 72.50 I hereby certify that the plans and specifications covered by Review of the plans and ��'��5�"'�r.� this�calculation are in compliance with the Florida Energy specifications covered by this �, �_ "'= .�_� O Code. calculation indicates compliance �,�!!�t'1r , '.:;;��,,�w��,,. �a�e �G�l�rcl� �th the Florida Energy Code. � frr:r:�''��..,��'���'��ti O PREPARED BY: Before construction is completed ,w��,,� � ' 4� � � DATE: this building will be inspected for �}; "'h�,��;.- - ':� compliance with Section 553.908 ��'-�� :�. I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. � Y fY 9, 9 P ��, . ��s. _ with the Florida Energy Code. �77?.WE'� OWNER/AGENT. BUILDING OFFICIAL. 'i DATE: DATE: � - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. ' , - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. 3l17/2017 7�48 AM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4 I f � FORM R405-2014 PROJECT Title: 2268 sf ADS Bedrooms: 4 Address Type: Street Address Building Type. User Conditioned Area: 2267 Lot# Owner• LENNAR HOMES Total Stories: 1 Block/SubDivision: #of Units: 1 � Worst Case: Yes PlatBook: Builder Name: LENNAR HOMES Rotate Angle: 0 Street: Permit Office: Cross Ventilation: No County� Pasco Jurisdiction: Whole House Fan: No City,State,Zip: , Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE � IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Block1 2267 21083.1 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 Main 2267 21083.1 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 242 ft 0 2267 ft2 �_ 0.3 0 0.7 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch \� # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2535 ft2 0 ft' Medium 0.85 N 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC II 1 Full attic Vented 300 2267 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 2267 ft2 0.1 Wood 3/17/2017 7�48 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS Adjacent SPa� Cavity Width Height Sheathing Framing Solar Belo w 1 N Exterior Concrete Block-Int Insul Main 4 1 12 8 9 4 118.2 ft' 0 0 0.6 0 2 S Exterior Concrete Block-Int Insul Main 4.1 31 4 9 4 292.4 ft= 0 0 0.6 0 3 E Exterior Concrete Block-Int Insul Main 4.1 - 64 0 9 4 597.3 ft2 0 0 0.6 0 4 W Exterior Concrete Block-Int Insul Main 4 1 75 9 4 700.0 ftZ 0 0.6 0 _5 N Garage Frame-Wood Main 11 28 0 9 4 261.3 ft2 0.23 0.01 0 _6 E Garage Frame-Wood Main 11 11 0 9 4 102.7 ft2 0.23 0.01 0 7 N Exterior Concrete Block-Int Insul Main 4.0999 4 8 11 4 52.9 ft2 0 0.600000 0 S S Exterior Concrete Block-Int Insul Main 4.0999 15 4 9 4 143.1 ftZ 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Main None .2 3 6 8 20 ft2 2 N Wood Main None .4 2 8 6 S 17.8 ft2 WINDOWS Orientation shown is the entered orientation(_>)chan ed to Worst Case. / Wall Overhang \� # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 7 Metal Low-E Double Yes 0.56 0.28 6.0 ft2 5 ft 0 in 0 ft 8 in None None 2 N 1 Metal Low-E Double Yes 0.56 0.28 32.0 ft2 1 ft 0 in 1 ft 6 in Drapes/blinds Exterior 5 3 S 2 Metal Low-E Double Yes 0.54 0.31 48.0 ft' 1 ft 0 in 0 ft 8 in Drapeslblinds Exterior 5 4 S 8 Metal Low-E Double Yes 0.58 0.32 96.0 ftZ 10 ft 0 in 0 ft 2 in Drapes/blinds Exterior 5 5 E 3 Metal Low-E Double Yes 0.54 0.31 23.0 ft2 1 ft 0 in 0 ft 8 in None None 6 E 3 Metal Low-E Double Yes 0.54 0.31 12.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 7 W 4 Metal Low-E Double Yes 0.54 0.31 48.0 ft2 1 ft 0 in 0 ft 8 in Drapes/biinds Exterior 5 8 W 4 Metal Low-E Double Yes 0.54 0.31 12.0 ft' 1 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 - GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 595 ft= 595 ftZ 60.2 ft 9.3 ft 1 INFILTRATION - # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000235 1756.9 96.45 181.�9 .2216 5 3/17/2017 7:48 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 3 of 4 FORM R405-2014 HEATING SYSTEM # System Type Subrype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.7 32.8 kBtu/hr 1 sys#1 � COOLING SYSTEM - # System Type Subrype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15.2 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation - 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Coliector Model# Area Volume FEF None None ff2 DUCTS � —Supply— —Return— � Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 600 ft� Main 11.25 ft Prop.Leak Free Main —cfm 68.0 cfm 0.03 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin [ ]Jan [ ]Feb [ ]Mar [ ]A r Ma [X]Jun X Jul [X]Au X]Se [ ]Oct [ ]Nov [ ]Dec � Heatin9 [X]Jan [X]Feb [X]Mar [ ]APr f �MaY [ ]Jun f �Jul [ ]Aug 4 ]SeP [ ]Oct [X]Nov [X]Dec Ventin [ ]Jan [ ]Feb [X]Mar [X]A r [ Ma [ ]Jun [ Jul [ ]Au [ ]Se [x]oct [X]Nov [ ]Dec Thermostat Schedule. HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling�(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78' 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 � Heating(WEH) AM 66 � 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 1 -Electric Heat Pum 0% 1 -Central Unit 3/17/2017 7�48 AM EnergyGaugeB USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 � ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 � The lower the EnergyPerformance Index, the more efficient the home. � „ FL, 1 New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1904.00 ftz b.Frame-Wood,Adjacent R=11.0 364.00 ftz 3. Number of units,if multiple family 1 c.N/A R= ftz 4 Number of Bedrooms 4 d.N/A R= ftz � 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 2267.00 ft2 ' 6. Conditioned floor area(ftZ) 2267 b.N/A R= ft� 7. Windows" Description Area c.N/A R= ft� a. U-Factor• Dbl,U=0.54 143.00 ftZ �� Ducts R ft= a.Sup:Attic,Ret:Main,AH:Main 6 600 SHGC� SHGC=0.31 b. U-Factor Dbl,U=0.58 96.00 ft� SHGC� SHGC=0.32 12.Cooling systems kBtu/hr Efficiency c. U-Factor Dbl,U=0.56 38.00 ftz a.Central Unit 34.8 SEER:15.20 SHGC: SHGC=0.28 d. U-Factor N/A ft� 13.Heating systems kBtu/hr Efficiency I SHGC• a.Electric Heat Pump 32.8 HSPF:8.70 Area Weighted Average Overhang Depth: 4.206 ft. Area Weighted Average SHGC� 0.309 � �8. Floor Types Insulation Area 14 Hot water systems z a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 2267.00 ft EF 0.95 � b.N/A R= ftz c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy EfFiciency Code for Building �,��&Sr�� Construction through the above energy saving features which will be installed (or exceeded) o. � � � . in this home before final inspection. Otherwise, a new EPL Display Card will be completed ,w4'��`- ;'��0�. based on installed Code compliant features. h r�,,,r,��'%,' k=;:�.';��`�`w„�pr� s�$' �i '..:.�tti A...� �.'s Builder Si nature. Date � '���' ""�'�� .� 'i 9 03/17/.17 4���, * � .� �. Address of New Home. 6528 Paden Wheel Street City/FL Zip:Zephyrhills, FL 33541 ��.� .�g'� , op y��. *Note. This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient , mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) i� 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support I, staff. ""Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. II 3/17/2017 11:20 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 i � . Buildin Anal sis Job: 2268sf g y Date: 3M 7l2017 ' Enfire House By: Dave Bayonet Plumbing Heating and Cooling 8950 New York Ave,Hudson � . - • • For: Lennar Homes ! - e s • e Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • I Component Btuh/ftz Btuh % of load Walls 5.6 9246 27.6 Glazing 21.8 6006 17.9 Doors 23.5 466 1.4 Ceilings 1.3 2844 8.5 Floors 3.6 8064 24.1 - Infiltration 1.7 3359 10.0 - D ucts 3493 10.4 ` Piping 0 0 " Humidification 0 0 �^ Ventilation 0 0 Adjustments 0 ' "- Total 33476 100.0 • s � Component Btuh/ft2 Btuh % of load Walls 2.8 4599 16.1 �� Glazing 41.5 11424 40.0 Doors 18.4 365 1.3 Ceilings 1.7 3816 13.4 , Floors 0 0 0 � , Infiltration 0.4 698 2.4 �i D ucts 3927 13.7 Ventilation -0 0 Internal gains 3750 13.1 ° Blower 0 0 �,„„ �,.,, Adjustments 0 ' Total 28578 100.0 � Latent Cooling Load= 3170 Btuh Overall U-value= 0.105 Btuh/ftZ-°F Data entries checked. 2017-Mar-17 07:37:27 � wrightsofta Right-SuOe�Universal 2013 13.0.09 RSU05714 pa e 1 9 � H:\LENNAR LOADS12268 sf ADS drawn 3 ton.rup Calc=MJ8 Front Door faces:SW Pro ect Summa Job: 2268 sf J � Date: 3H 7/2017 " Entire House By: Dave Bayonet Plumbing Heating and Cooling 8950 New York Ave,Hudson ! • 0 8 For• Lennar Homes Notes: ADS specs � - • e s Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD - 39 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 55 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 29983 Btuh Structure 24652 Btuh Ducts 3493 Btuh Ducts 3927 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 33476 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 28578 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2449 Btuh _ Ducts 721 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 2267 2267 Equipment latent load 3170 Btuh Volume(ft') 21250 21250 Air changes/hour 0.22 0.11 Equipment total load 31748 Btuh Equiv.AVF (cfm) 78 39 Req. total capacity at 0.85 SHR 2.8 ton Heating Equipment Summary Cooling Equipment Summary , Make Lennox Make Lennox - Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-036-230-18 Cond 14HPX-036-230-18 AHRI ref 5187082 Coil CBX27UH-036-230'`++TDR AHRI ref 5187082 ' Efficiency 8.7 HSPF Efficiency 12.5 EER, 15.2 SEER Heating input Sensible cooling 29580 Btuh Heating output 32800 Btuh @ 47°F Latent cooling 5220 Btuh Temperature rise 25 °F Total cooling 34800 Btuh Actual air flow 1200 cfm ' Actual air flow 1200 cfm ' Air flow factor 0.036 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.90 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .�. WCI �'ItSOft` 2017-Mar-17 07:37:27 � 9 Right-Sulte�Universal 2013 13.0.09 RSU05714 Page 1 �C�` H:\LENNAR LOADS�2268 sf ADS drawn 3 ton.rup Calc=MJ8 Front Door faces:SW _J Manual S Compliance Report Jo6: 2268sf . Date: 3/17/2017 Entire House By: Dave Bayonet Plumbing Heating and Cooling , 8950 New York Ave,Hudson � • ' � i - For. Lennar Homes s • o e • Design Conditions Outdoor design DB 91.3°F Sensible gain: 28578 Btuh Entering coil DB� 75.6°F Outdoor design WB. 77.3°F Latent gain: 3170 Btuh Entering coil WB. 62.8°F Indoor design DB: 75.0°F Total gain: 31748 Btuh Indoor RH� 50% Estimated airflow: 1200 cfm � Manufacturer's Pertormance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Lennox Model: 14HPX-036-230-18+CBX27UH-036-230*++TDR Actual airtlow: 1200 cfm Sensible capacity: 29581 Btuh 104% of load Latent capacity� 5220 Btuh 165% of load Total capacity 34801 Btuh 110% of load SHR. 85% s � • Design Conditions ' Outdoor design DB: 30.8°F Heat loss. 33476 Btuh Entering coil DB: 69.6°F Indoor design DB. 70.0°F Manufacturer's Performance Data at Actual Design Conditions - Equipment type: SpIitASHP Manufacturer Lennox Model: 14HPX-036-230-18+CBX27UH-036-230*++TDR Actual airflow� 1200 cfm Output capacity: 32800 Btuh 98% of load Capacity balance: 38 °F Supplemental heat required: 676 Btuh Economic balance: -99 °F Backup equipment type: Elec strip � Manufacturer n/a Model: n/a+n/a Actual airflow: 1200 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 °F The above equipment was selected in accordance with ACCA Manual S c wri htsoft' 2017-Mar-17 07:37:27 - �� 9 Right-Suite�Universal 2013 13.0.09 RSU05714 Page 1 �'� H:\LENNAR LOADS\2268 sf ADS drawn 3 ton.rup Calc=MJB Front Door faces:SW 6528 Paden Wheel St I • ' o umn SQ. FEET PRICE UNDER ROOF: 3,038 $ 112.65 OTHER: - $ - VALUATION $ 342,230.70 FEE SHEET $ 1,217.00 ADDRESS $ 40.00 D,RIVEWAY $ 40.00 BUILDING: $ 1,321.34 ELECTRICAL: $ 273.83 PLUMBING: $ 182.55 MECHANICAL: $ 127.79 SUB-TOTAL $ 1,905.50 TOTAL $ 1,905.50 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL � TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 , SUB-TOTAL $ 2,458.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 . TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 ' 1% $ 36.32 TOTAL: $ 11,736.69 OS-26-21-0070-00300-0100 � Pasco County Property Appraiser Page 1 of 1 �^ ,� �� ,r�v� � Data Current as Of: Weekly Archive - Saturday, April 15, 2017 Parcel ID 05-26-21-00.70-00300-0100 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address � Property Value , DUNE FL LAND I SUB LLC Ag Land $0 C/O HAWK MANAGEMENT CO LLC Land $26,799 2502 N ROCKY POINT DR STE 1050 Building $0 ROCKY POINT FL 33607-5995 Extra Features $0 Physical Address 6528 PADEN WHEEL ST ZEPHYRHILLS, FL 33541 7ust Value $26,799 Assessed (Non-School Amendment 1) $26,799 Legal Description (First 4�ines) SILVERADO RANCH SUBDIVISION Taxable Value $26,799 PHASES 2, 3 &4 PB 73 PG 059 BLOCK 3 LOT 10 �urisdiction City of Zephyrhills � Land Detail (Card: 001 of 001) --,----- -- —�---- Line Use iDescriptiornZoning �Units ;Type Price Conditi_o_n_�V_ alue _ 1���_ 0100 v� SFR MPUD 6,000.00 SF $4.25 v1.00� $25,500 2 � 0100 � SFR , MPUD 3,937.00 � SF $0.33 �� 1.00 � $1,299 Additional Land Information , ---- r______�? ' FEMA� �_ � Acres 0.23 ; Tax Area 30SI j Code -- '^esidential Code� SLVRLPI f � I I I Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved ' Extra Features (Card: 001 of 001) --r----- ----- �-- -- �----- Line�� �Description �jYear Units ��_'1Va1ue � No Extra Features Sales History- See All 5 sales Previous Owner: �.��__ ,_.__�_ � Month/Year �Book/Page �Type�__� DOR Code Condition Amount 09/2011 8606 / 3376 �Warranty Deed 05 � Vacant .j Multi-Parcel Sale _` 05/2010 � 8373 / 1912 ____, Certificate of Title _ 12 Vacant ; $0 07/2005 6725 / 1059 i Quit Claim Deed � ( Vacant 1 � $0 http://search.pascopa.com/parcel.aspx?sec=05&twn=26&rng=21&sbb=0070&b1k=00300... 4/20/2017 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permittin 813 363 __ 2891 �r Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700 Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name N�A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 6528 Paden Wheel Street LOT# 0100 SUBDIVISION Silverado Ranch Subdivision Ph 2,3,84 pARCEL ID# 05-26-21-0070-00300-0100 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED I��/ I� NEW CONSTR e ADD/ALT � SIGN � � DEMOLISH � INSTALL REPAIR PROPOSED USE � SFR � COMM � OTHER TYPE OF CONSTRUCTION � BLOCK Q FRAME � STEEL � DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF 3038 SQ FOOTAGE 2277 HEIGHT 1 Story 1"ITTrT ✓ BUILDING $ y/ /b VALUATION OF TOTAL CONSTRUCTION rbd '�/ 'ELECTRICAL $ � � PROGRESS ENERGY Q W.R.E.C. , . r AMP SERVICE �PLUMBING $ �� � 1� � . �MECHANICAL _ $ VALUATION OF MECHANICAL INSTALLATION �GAS � ROOFING Q SPECIALTY � OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA �YES �JO LJ ��F:�-:-i--i--:-1--1--F-:--^�--:-�1--1-�1�-1--�-�1--1--1-��:-:--r:--:-���1--1--l-:--:�-rF���l-4�-f�-1-�1-�F-�1-i--f-�1--F-1--�i--�- BUILDER COMPANY Lennar Homes,LLC • SIGNATURE � ' REGISTERED Y/ N FEE CURREN Y/N Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 License# CGC1518166 ELECTRICIAN COMPANY Edmonson Electric, �I1C. SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 1034 Skipper Road, ampa, FL 33613 �icense# EC13005408 PLUMBER COMPANY BayOn2t PIUIllblllg, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, Bayonet, FL 34674-5308 �icense# CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, Bayone FL 34674-5308 �icense# CAC058062 OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4211 Shoal Line Blvd, Spring Hill, FL 34607 License# CCC05.7991 1111111111111111111111111111111111111111111111111111011111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects I COMMERCIAL Attach(2)complete sets of Building Plans'plus a Life Safety Page;(1)set of Energy Forms.R-0=W Permit for new construction. ' Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. *""PROPERTY SURVEY required for all NEW construction. ' -1.a-1..1-.1--1--�-I..�i�p••:-C-:..:�1..1..4.1..�1--1..�1--1�'.�-:..'�1..1-�1..4.{a..L�L.��1..4.1..1..4�1..1..L�1..��L�1--1-�' '.�-.-:-'r�4.��{� Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) " Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(PIoUSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS� The undersigned understands that this permit may be subject to"deed" restrictions" � which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UPIL:ICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES. If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for.the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign ' portions of the "contractor Block" of this application for which they will be responsible If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IfVIPACT AND RESOURCE RECOVERY FEES� The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWfdER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to. - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall • - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEVIIIENT. • FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)bef re e this Subscribed and sworn o(or affirmed)before me this � i e-iviar-i� by paul Sweeney ,s-Ma�-,� by Pa 1 Sweene Who is/are personally known to me or Who is/are personally{nown to me or as identification. as identification. --- � L � '` Notary Public Notary Public Commission No. FF98537 Commission No. rF98537 Elissa M.Holleran Elissa M.Holleran Name of Notarv tvoed,printed or stamped Name of Notary typed,printed or stamped ���. ... ""' �€I��l4N.�I�lt�p1V' ,r.� . E�I��h�,N�l��t� ''� � t �s ��Rr����i;�PF@l4817 � r C�ttm"�7'm1MPPp�e�� ,��, �rp�'s�hrr,��d;��tl '�5.�9�dUts�d��(�� � (d�ni�F►F,T �tu9rr.7�lC�a�10 , - [l�.i��i�YFa�:�F��R�Sn�l�t 1e�T4lB " �9+ Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. 9. No electric,plumbing, mechanical, or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. ' 22. A112008 N.E.C. Codes will be enforced. 23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 � 22. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 5'�'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008) � � - - � r �� , _ -• , i � � �.. - , '� - _ g � ' �. � � �,��' i � ' � 6 �, .•" ' '�. � �` �r � `� 'a� o•r 1�F=1Q9.60 1� , � �l�' _5 FF=1Q9.90 FF=1,09.70 � �� `�, ' c-. �� �''�er � � �- � LOT 12 - � � �� . `'o-� LOT Z L07 1 -;.� -- �• 9.` 1 t� 1 _ PAD=108:9 `� � � �'� � C� 0 � � �� � PAD=109.0 �� ,,,-s'• ! �' �� �� _ �' � T��e �, ,, � ' �}g. � O C�'D � �g ;,�0' � 7�E A . , r �Y �ie- 1 '7' ' �� ` •� � FF=11�T_30 - � ,0 '�� �� . � r ' ;ro�'� e• � '` �` '.^:� � � LOT 9 , � �• ,''o ) - ro� �' �s- � • � PAD=f 09.6 , ' � f � \ 6" i<�' 1 � ' �� � o- n-� � �. � 1 ,`,\'�1'0" � �\ TYPE A , `� �� � �. �\ "• . ,r �r v- N s � � � ,�� � 110. �� � � ,e-a• �. A � FF=1 Q9.50 � � � 1 � � � � a, : �' ,'s. m• ��- LO��t 1 ��. '1 � �� �� �� ;. � . c• ,�� �\ � ' P,aOl- 08_� O i` "�r TO g ;� � �j�` O1 r� � ~ � �`,` ' .,'�� •; • \•� 1\ R 1' 6• � �6' `�`i .i���YPE B �Y r� �� ' `.t'� } =110.�q �� 0 `�` � .ti ��� - '`� � LaT_�'�r g� p-� °'� �1�� J� c �� 0"k -..��rso�+ t �j1r es �� S . PAD=:110.0 r-� -,-1 -a�,^ �- ��; - 01 � ��� _ 6. .� I J � , � � TYPE A o �OT��_3p , 1 - e-�i �'� o{y° �t `� F�=110.80 FF=110.60 PAQ=109.6 � y�'y � � - � �,'�r�is �� 20 .•�" s- _ ��r � _ `� LOT 11 L4T 12 TYPE A L ,;• �Q\ '" �" FF=10t���o' � �. � PAD=11�.1 '• b�� - I LOTs;J, � � 0'1 1 , \�• TYPE A P nPE0A.9 I ',r� 1 \ , �� "' _ PAD�--T� T i '1 p,�J, `� � - ' � i � , $\ �6��� - � c �� � • �,0 6 �,� o� �� `�- ,,�^ � , ,�,-v�'\\���, i •� �� � ---I 6 1�� '_��1CJ ��'� �o .1 ^1� \g? g• _ �� a•Y c�a 1 � _� _-r'� � 0 � +' p,,�� � �^1 - � i • 06 � , , Ak� _ :� � ` �r� _ i�v r�`'� ___�i68_33 -�o .1�� 6 tz'�i 0�����.n 20' DRAINAGE E0.SEMEN7 � �� � � pQ sr� -`_ �"--'_-- ' ,�o ti7 '�wly�g���� -�'----(�----- }8 � ,�• � 10 U77 E45cMENT 1 -6"--- \�� o zr l°� .,a'� �G•n �j' . � " � '`�� '1 ,�9' -- �z\ � � �p7 os.8o ` 3r � � .,, ^� -. ��� ��� ,�o (e�T 9 , � .i� � \ � � �Fi �• - '�--C�-r° • `� v�o . �1 � �� �s- i�i1=108.1 $ `� _'�v _ '� �• _ 1 • ' '��. �� �- �PE B � ' ' -_ --- ' `1 �� � r� � ' n � 1O '-� �'^ - U� r �` �'��'1 ' �; �, �r��r ' '-,� ` _ ' -, _ _ � . '��.,�� � ' Q _ ------ P7-88 8 • ` ; _ 1Q' �LI7Y� _ EME�'L_� _ _ � � `� ��',,,ir • � - � FF=1 Q9.90 �' ,r ' r FF'=1a4.n0 -' __ • LOT 1 \ 6�" r�z•„�5� �QT� � '� J PAq_�'08.3 FF=1�9_20 PAD=109.2 � � �:°' �a- "� �" TYPE-� . L FF=1 t0.2(� FF=110.50 FF-1 � _ -- LOT�2 O TYPE 8 �� , �jp ` ���,r - �.T 7 ro LOT 6�v LOT 5 '` 1 .50 FF 11o_3Q� � PAD=109.d �'l _�-. \ �� s `V ��-108.5 . -.PAD��8.5 • PAD=tfQ418 LOT 4 LOT_-3"� TYPE B c, ��' . °J� ��}� � - � TYPE B •. � B PAD=109.8 PAD=109.6 ;� � c �5 ;� „• � - �.. T��'� TYPE R�I TYPE B C��J �,1� �ro` � ��� °C� �\�`�'` � 1v 1V '�0 J 107. 1t1- 3� � Q��75' � � _ \ \ \ _ r �e���°� �"'�,L,,r r�� �' :... - - _ ".--- -_ �.'" - a �, 4 � �, r � . ..- - . � �� ���... �oc � 4 - � �, r ��j,s��R i7�: ^'�ir "9. r �O �- _,1� _'� ,,O"' ,�h:v' C� 18'(87. - - ` ! , �� \�� ���` � . T,�O c� -- - .�_ = - c�-' s/a ` WETLAND \��;o��.�.��,. .:T' , - , �- - - - - - ��-- - , _r� - ��.� °� c �� �� � _ -_ � ' �� Y . . �--""z-� � p ` y,y�� v� 2S• � C O ' 4' v iT\ . . 1 ' ' �/ 'ri+�i N , S V ER T A1 � 0 � , � N -�- � ,r . � �8� �-� � b- � ti, p. � � \ '��'� �\ e', �- a'� °Q��� 7 �''g��a��'�$'p'��$ . � AREA P �- � �'. "- ,,. R r " .�,�- �� r _� �s> �'. . '\ �6. a1,, .� + �,�, T �- �,.r "' P�s. p �' a'�'�'_=��s' -' " �-��r `Z4 s-'�o_ 6' �' /►�..� �tY - . (1 .22) AC. , :_ _ --- -- �.� o� � � _ _ ��- - 6- � P� �� �- o�-�-��'.� � `'- -� • `a-r r� s r�c .-r ,s�'� � . lDOYRDNW=104•0 --•__ ___ . CONTROL SFRUCTUR�C Oew s- � �\O • �' ' � •� a�T o.�+%��� , - ` _ . "' --- ,_ ..__ , ��^ � \ �,�E�' d � 9',��j'�6.. ' " �S� �Q- 6 i '�� � � ` . . Ci �o?�T � �r --�� � �y, ' . •. . . - • _ _ _ . _ ... .. , __" __- _ " __ - -_ � ___ __'_._--__-__'_-_..- ._.___ __ ._- + ' _ .:--•-,--- AO SF Rf 1RAI F � A� ��r --�1� M1 SKETCH dNLY SEC. 05 , TWP. 2� S, RNG. �� E. PLOTfF'LAhI iVOT A BQUNDAftY SURVEY L�T �I O, BLO�K 3 BEARING 9AS15: SILVERADO RANCH SUBQfVISION NORTH BOUNDARY OF SE�/a OF 05-26-21 BEING N 89•2s'a�" E PHASES Z, �J $C q- TH1S SURVEY ES SUBJECT T4 ANY FACTS THAT PASCO COUNTY, FLORlDA. � MAY BE DISCLQSED BY A FUL4 AND ACCURATE T1Tt,E SEARCH. AlSO 5UBSECT TO SETBACKS, ON LG►T ARF_'A CALCULATIONS EASEMENTS AND RESTRICTIONS OF RECORD. i 4.OT =_gg37•08 SQ. FT, a' UNDERGROUND FOOTER, STEM WALL, AND ' i.tVfNG AREA = 2267 SQ. FT. � M UNDERGR4UNd UT{LITIES ARE NOT �OGATEII dR ENTRY =23__SQ. FT. �� SHOWN. GARAGE = 58� $4. FT. :- GOVERED LANAI =�.L 'SQ. FT. DO NOT SCALE THI5 PRINT. DIMENSIONS AND pq-�p = NIA Sfl. FT. .'`�.+ NOTES TAKE PREFERENCE. CONC. DRIVE = 561 SQ. FT. � AJC & CdNC PAD =9 Sp. FT. DESCRIPTIdN NOT CONTAINING PLAT BOOK AND PRlVATE SIDEWAIJC = 40 SQ. FT. PAGE INDICATES THAT P�AT IS IN IMPERVIOUS = �a _.9= PRELIMINARY STAGE AND IS SUBJECT TO = 3728 SQ. F7. - CHANGE ANQjOR REVISIQN. SOD =�209 SQ. FT GERTAkN DATA SHOWN HEftEON BASED ON OFF LOT AREA,CALGUL.ATIONS ENGINEERING PLANS PROVIDED BY CLiENT. R(GHT OF WAY =S�5Z,3.�S4. FT. SIRUCTURE 17ES SHOWN HEREON DENOTES DRlVE APRON = 350 SQ. FT. MEASUREMEN� FROM FORM $OARDS/FOUNQATION PUBLIC SIOEWALK = 532 S0, FT. � � TO PROPERIY LINE. �pp = 1475 SQ. FT. �, a * = }q' {}7{��Ty EA5EMEN7 TOTAI..S AftEA = 1�894•?�SQ. FT. S �OT 2 DR�VEWAY =g11 S4. FT. ' `st° BLOCK 3 SIDEWAL.K = 572 S4. FT. . '�j, SOD =_�z84�.S4. FT. � "'�O•� �� � PRELIMIMARY DRAWWG: gLOGKg3 .�;y� e'O 't�E1S PIAN !S fOR PERMtTTING PURPOSES �53, ONLY, NQT FOR CONSTRUCTION. VERIFY - _ AL� DIMENSIONS BEFOR£ ANY CONSTRUC'f}aN. D�� '3p: �R�• s .Qq c . ���o�°l LEG�ND: � • ' „�---+�-= QROPdSEO DRAlNAGE FC.OW � ��y (00.00) = PROPOSED GRAOE � „?M' E-04.00 = EX�S'fTNG GRADE �. � . � '�� i - �� . C �' S S''6~ � �, p ssa8�. ^i fo0 R{)AO '�'£ r`30g%- .,.� 2 � �'� Fj��0� �, 1�.:� �, '�4G,��.. �"4ry. Q? o �.?s �o ,�,�� ^- � - � .�, &�oc�o Nt. � A /(' � 4 41" E ',' s er,o'as'E . 3 \ N15g , `:,.�v . . . ..as'e�" •- . :: ,,. 'S h.`39.- � LOT 11 \ � "� BLOCK 'a " �.AcAI"A� - ry��`'yh.'� � , � ry �'� .e .'�'`.�2E0p:.. U3 � :�^c;.•�hv?: � �: .�.;_�� � _�_ . .`L, �,, .2S p¢, .O ..�,�5�'..�400;N .� �q . � ry0\� � ��� ,,,� '. + • . ``"�.,. � �,��,�j/''�� • , ��a$a,l � q� �/� � /��j r q�`�J' �' "?�'�'�� r. T � o � NOT�s: �� F�T� o M �OT GftADlI�G TYf'E = A � . � PROPOSED PAD ELEVA710N = 110.0' �, FROtdT SET BACK = 20' � ` `�. � 51f]E SET BACK = 7.5' ��� o REAR SETBACK = 15' �"' r ~`� �; PROPQSED: � CURVE RADIUS ARC CN6RD BEARtNG DELTA LOWEST FLOOR ELEVATIQNS: m C752 277.00' 105.31' 104.68' N 57'46'25' W 2T'46'S7" , � L(ViR3G AREA: 110.70 �, GARAGE AREA: � 1�ESCf�1PTIQ�I: ELEVATIONS REFERENCED TO = LOT 9 Q, BLOCK 3, MAP Oft PlAT EN7lTLED "SILVERADO RANCF! SUBDIVISIOR! NORTFi AMER(CAN VERT(CAL � PHASES 2, 3 & 4�", AS RECORDED IN PIAT BQOK 73, PAGES 59 THROUGH z DATUM OF 1988. MEAN SEA z 65, OF TNE PUBL(C RECORDS OF PASCO COUNIY, FLORIDA. LEVEL— OO.QO FT. a g APPARENT FL(70D NAZARD ZONE: "X" COMMUNITY PANEL NO. 12Q230 0455 D EFFEGTIVE DATE. 09 j30f3992 � LEGEND: 'J {C)= CA�CU�ATED DATA, {D}= DEED DATA, (M)= MEASURED OA7A, (P)= PIAT DATA, �= CENTERLWE, AjC- AIR CONDiT10NER, BJG- BACK OF CURB, C/5= ;;y CQNCRETE SLAB, CH= CHORD, CHB= CHORD BEARlNG, CLF= CHAIN LINK fENCE, CONC= CONCRETE, COV.= GOVERED, EjP= EDGE OF PAVEMENT;ESM'T= EASEMENT, z F/C= FENCE CORNER, �CM= FOUND CONCRETE MONUMENT, F�P= FOUND IRON PIPE, F1R= FOUND IRON ROD, FN&D= FOUND NAIL& DISK, FPp= FOUND PINCHED � PIPE, LFE= LOWEST F�OOR ELEYATlON, MAS.= MAS4NftY, OR= 4FFICIAL RECORD BOOK, P8= PLAT BOOK, PGA= PERMANENT GON7RQL P44MT,'PRM= PERMANEiST � REFERENCE MdNUMENT, R/W= ftiGHT OF WAY, R= RAOIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM=� TEMPORARY BENCHMARK, x U P= U77LITY PQLE W F= WOOD FEhlCE R = RADIAL x JQHN R.BEACH&ASS�GlATES�IPIC. Drqwn 6 S�� � Y Square Feet: g937.Q8 t IENNAR HQMES � � SURVEYORS AND MAPP�RS Checked B .� � 91i WEST S7. PETERSBURG DR1VE � �R� _, - n ONE OLDSMAR, FLORIDA 34677 ' ` ` � WAY (gi3) 854-i27& FAX (813} $55-8370 S°°�e' 1"=30' a \ '.�� � ��/ S NdT VALID WiTHOUT THE SIGNAIUftE AND �ote: PLOT PLAN 3 13 i7 ACS 5 TNE ORIGINAL RAISED SEAL OF A FIORlDA J N BEACH DA � LtCENSED SURVEYdft AND MAPPER LORIDA EG. LAND SURVEYOR No. 2984 LB�/4493 � Revisions: SKETCH 6f28ji6 ACS