Loading...
HomeMy WebLinkAbout17-18397 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 18397 � ' ' BUILDING PERMIT SINGLE FAMILY RESIDENTIAL r - ' PERMIT_INFORMATION LOCATION INFORMATION � � �ermit#:18397 Issued: 4/28/2017 Address: 6564 PADEN WHEEL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 420,866.52 Total Fees: 12,087.69 Subdivision: SILVERADO Amount Paid: 12,087.69 Date Paid: 4/28/2017 Parcel Number: 05-26-21-0070-00300-0090 CONTRACTOR INFORMATION - OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 15550 LIGHTWAVE DR Address: 4600 W. CYPRESS ST STE'200 CLEARWATER, FL. 33760 TAMPA, FL. 33607 Phone: (727)479-1740 Lic: Phone: (813)574-5700 Work Desc: CONSTRUCT SINGLE FAMILY HOME 3,957 SQ FT APPLICATION FEES � BUILDING FEE 1,560.01 ELECTRICAL FEE 326. 8 PL B N EE 217.65 MECHANICAL FEE 152.36 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5°/a 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfd100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 � ���� I � � 6 Ins ections Re uired � F OTER 2ND ROUGH PLUMB MIS INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your properly. If you intend to obtain financing,consult with your lender or an attorney , before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. ; � CONTRACTORS IGNATURE , PERMIT OFFI PERMI EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO ALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER � 6564 Paden Wheel St o umn SQ. FEET PRICE UNDER ROOF: 3,957 $ 106.36 OTHER: - $ _ ' VACUATION $ 420,866.52 FEE SHEET $ 1,451.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,560.02 ELECTRICAL: $ 326.48 PLUMBING: $ 217.65 MECHANICAL: $ 152.36 � SUB-TOTAL $ 2,256.50 TOTAL $ 2,256.50 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES - PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 - TOTAL: $ 553.35 SUB-TOTAL $ 2,809.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 �- 99% $ 3,595.68 1% $ 36.32 - � TOTAL: $ 12,087.69 _ .` �-. � i 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 \ Building Department U v O�i �� Gi..LoJ� Date Received ��� �� Phone Contact for Permittin 813 363 __ 2891 Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700 Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 • Owner Phone Number Fee Simple Titleholder Name N��' Owner Phone Number I Fee Simple Titleholder Address N/A JOB ADDRESS 6564 Paden Wheel Street LOT# 0090 SUBDIVISION Silverado Ranch Subdivision Ph 2,3,&4 pqRCEL ID# 05-26-21-0070-00300-0090 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED II✓ II NEW CONSTR e ADD/ALT � SIGN � Q DEMOLISH � INSTALL REPAIR PROPOSED USE � SFR Q COMM 0 OTHER TYPE OF CONSTRUCTION � BLOCK Q FRAME � STEEL � DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF 3g57 SQ FOOTAGE 3�27 HEIGHT 2 StOry ✓ BUILDING $ �-7 �� VALUATION OF TOTAL CONSTRUCTION / I�/ IELECTRICAL $ � PROGRESS ENERGY Q W.R.E.C. ' ' ` AMP SERVICE �PLUMBING $ ��� � � �MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION �� �GAS � ROOFING Q SPECIALTY � OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA �YES �O »r u -}-�-'• ' '�^"r' �--F� 1--F�I--��:--Fe��'re'-:'-C-r{-�1-i-1--{-1-' H-:--'-^'- BUILDER _ COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4600 W.C ress St.Ste.200,Tampa,FL 33607 License# CGC1518166 ELECTRICIAN COMPANY Edmonson Electric, ��1C. SIGNATURE �'� REGISTERED Y/ N FEE CURREN Y/N Address 1034 Ski er Road,Tampa, FL 33613 �icense# EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE ��" REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 308, Bayonet, FL 34674-5308 License# CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE �� REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5� 8, Bayonet, FL 34674-5308 �icense# CAC058062 OTHER � COMPANY � �r/'�� SIGNATURE � �" REGISTERED Y/ N FE CURREN Y/N address 4211 Shoal ine Blvd, Spring Hill, FL 34607 �icense# CCC057991 � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities 8 1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. f..l.-f..f-�1..��:..'r'� '�' '.�.�1..1�:�'� '�� . . . . 4�1��1�1-.�:.C�.^G '��.�..�7..{�{-....�.�C '��� Directions: - Fill out application completely Owner&Contractor sign back.of application,notarized If over$2500,a Notice of Commencement is required. (AIC upgrades over$7500) '* Agent(for the contractor)or Power of Attomey(for the owner)would be.someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(PIoUSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES� If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. . CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to. - � Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, WateNWastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Heaith Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill� - Use of fill is not allowed in Flood Zone"V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. , - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for viofating the conditions of the building permit issued under the attached permit application, for_lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. I If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by I the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A PIOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR --�— ___Sub_scribed and sworn to(or affirmed)_ efor_ e this Subscribed and sworn to(or irmed)before me this i�-�an-i i by paul Sweene ��-�a�-+�— —by Pau1�S eene - --� - Who is/are ersonall known to me r Who is/are personally kn wn to me or s identification. as identification. Notary Public � Notary Public Commission No. FF98537 ommissi o. FF98537 I Elissa M.Holleran Elissa M.Holleran Name of Notarv tvped,printed or stamoed Name of Notary typed,printed or stamped ��s...... �. �" '� �ll��kN.��I��I;. ""! � ��I��,�f.�IQIA�tI , a C!RlKhtib�t�I1�P8�'tAl7 ��: es�C�tcm�#'�n;�pCPB&�8�7 ` � ��V#��1t�r������0 t�d���r'ut�+e',�k�� �„�da��iairrratiyC+hi�an��t�s;t�Pli �';. _�' Bai�++i3YcrTa�yy�l��y�p�t�]I�T41F _. , I — - �. /�� �� t11Ufl : ��� ��-�,i'� , �N` City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: ����-����� Date Received: �v` �`� � Site: �G`� �� ��'� ����� � PermitType: ���'J '�y�l �GJ c3f�� Approved w/no comments:❑ Approved w/the below comments: C� Denied w/the below comments: ❑ , This comment sheet shall be t with the permit and/or plans. � / r � � Kalvin w'tzer Pl s Examiner Date Contractor an or Homeowner (Required when comments are present) � i iiiiii iiiii iiiii iiiii iiiii iiiii iiiii iiiii iiiii iiiii iiii iiii 2017061377 Rcpt:1857470 ITeC0.00�00 DS: 0.00 ppty Clerk 04/25/2017 C. F. , _ _- PRULA S 0'NEIL,Ph D PASCO CLERK & COMPTROLLER 04/25/2017 09:04am 1 of 1 OR BK �5�� PG �530 Permit No. Parcel ID No 05-26-21-0070-00300-0090 NOTICE OF COMMENCEMENT , state of Florida County ot PaSCO THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement: 1 Description of Property Legal SILVERADO RANCH SUBDIVISION PHASES 2,3 &4 PB 73 PG 59 BLOCK 03 LOT 09 sr�eetAaa�ess: 6564 Paden Wheel Street Zephryhills FL 33541 2: General Description oF Improvement Single Family Residence/Pool/Screen Enclosure/Fence ' 3. Owner Information: Lennar Homes, LLC Name ' 4600 W Cypress St. Ste 200 Tampa FL. 33607 Address City State Interest in Property Name of Fee Simple Titleholder• N/A (If other than owner) Address City State a. contractor• Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Contractor's Telephone No. $13.574.5700 5. Surety� : .,,��.:; N/A Name Address City State Amount of Bond: $ Telephone Na 6. Lender: N/A Name Address City State Lender's Telephone No.. 7 Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Hom LL Name 4600 W Cvpress St, Ste 200 Tampa FL, 33607 Address City State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner• i 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF,COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT STATE OF FLORIDA .� COUNTY OF PINELLAS . G ' Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/O�ce The foregoing instrument was acknowledged before me this �7 day of. dA 10/ ,by Steve Smith as Vice Pfesident (type of authority,e.g.,officer,trustee,attorney in fact)for Lennar Homes. LLC (name of part hom instrument was executed). Personally Known■OR Produced Identification❑ Notary Signat Type of Identification Produced Name(Pri i Holleran Verification pursuant to Section 92.525, Florida Statutes. Under penalties of rjury, I declare that.l have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. �,;���{�� �% ELI5S�M.HOLI.ERAN Signature of Natural Person Signing Above :�z""`Tfi: L� ;,�Crmmbblon M FF 885A37 � � �'r Ex�lres June B,2020 , wpdata/bcs/bcsform: �"fl��.,•'� AondNThmTroyFolnlMur�poe100�3p5-7pip I' ���6���,� �.� ��� �-` ` � �� .�y ��- rtY � � ; �� � 0r W .:���. � � Fnyod"k'e7n�st Q � � ��� (_� �$ \ � � � �n Ft�&7 . sm a � ��`���������� gTp,�'�0� FLORIi�A,CnUMTY OF PASCO THIS IS TO CERTfFY THAT THE FOREGOING IS A TRUE AND CORRECT COPY OF THE DOCUMENT ON FILE OR OF PUBLIC REFOCD INS AIL OFSICE WIT S JIY HAND r DAY F a S O'NEIL, RK&COMPTROLLER DEPUTY CLERK BY �— - . � LENNAR� May 5, 2017 Ci of Ze hyrhills Building Department I tY P 5335 8th Street Zephyrhills, FL 33542 To Whom It May Concern, Please revise the following permit because the site plan has changed. The site plan front setback has been revised. SILVER.ADO RANCH SUBDIVISION PHASES 2, 3, & 4 BLOCK 03 LOT 09 6564 Paden Wheel Street Permit# 18397 Thank You. If you have any questions please contact the office. Thank you for your cooperation. , Sincerely, lissa Holleran Permit Coordinator Lennar Homes Central Florida Division 813-574-5745 460o West Cypress Street Suite zoo Tampa,FL 33607•Phone:8i3-574-5700•Fax:8i3-574-5706 LENNAR.COM PL,OT P1rAN SKETCN ON�Y SEC. �� , TWP. 2� S, F2NG. �� E. NOT A BOUNDARY SURVEY LOT 9, BLOCK 3 BEARING BASIS: SILVERADO RANCN SUBDIVISION NORTt-t BOUNdARY OF SEt/a OF 05-26-21 BEthIG N 89'25'OS" E PHASES 2, J� 8L 4- THIS SURVEY IS SUBJECT TO ANY FACTS THAT PASCO COUR�TY, F�LORIDA. � MAY BE dISCLOSEO BY A FULI AND ACCURATE Tii'LE SEARCH. ALSd SUBJECT TO SETBACKS, PF2�LIMINARY CIRAWING' EASEMENTS AND RES7RICTIONS OF RECORD. THlS P�AN 3S FOR FER�ITTING PURP4SES M UNDERGR4URl0 FOOTER, STEt� WAL�, AND ONLY, NOT FOR CONSTRUCIIQN. VERIFY UNDERGROUND UTILITIES ARE NOT LOCATED OR ALL DIMENSIONS BEFORE ANY CONSTRUCTION. �� SHOWN. Dd NOT SCA�E TH15 PRINT. OIMENSlONS AND LEGEND: � NOTES TAKE PREFERENCE. ��= PftOPOSED DRAINAGE FLOW � (OO.OQ)— = PROPOSED GRADE � CfRTA1N DATA SHQ41+N NEREON BASED ON E-00.04 = EXtS�1NG GRADE ENGtPlEERING PIANS PR4VlDED BY C�(EPlT ON L.OT AREA GALCULATIONS STRUCTURE TIES SHOWN HEREON DENOTES �4T = 9887.05 SQ. FI. MEASUREhiENT FROM FORM BOARDSfFOUNdAT10N LIVING AREA �_ 1512___SQ. FT. TO PROPERTY LINE. ENTRY =38 _�SQ. FT. GARAGE _ ���M.r_S4. FT * = 10' UTI�ITY EASEMENT GOVERED �ANAS —�1$? S4. FT PATIO =_�?_.__SQ. FT. CONC. DRIVE = 606 _�SQ. FT. AjG & G4NC PAB = 13 �SQ. FT. ` PRIVATf S(DEWALK = ��_____SQ. FT. � 30 _% �` IMPERVIOUS _ �o V 3012 _SQ. PT. o� �07 3 S4D -_6$7�wSQ. FT. �- � BLOCK 3 OFF LOT AREA GALCULATIONS � ���� ` RIGHT dF WAY =,., 1959.52 SQ. FT. LOT 8 DRIVE APRON - 350 SQ. FT. BLOCK 3 � � Q PUBLIC SIDEWALK =_59� __SQ. FT. 1� � . �-�� �''� SOD =� 1413,.,,__SQ. PT 5 1 `!. a 'S�'� TOTALS _ 11846,57 SQ. FT. �`Z»2� � '' (t09.5o') AREA DRIVEWAY = 95& ,_,__S4. FT. �'j�� s �OT 2 SIDEWALK = 64S__SQ. FT N BLOCK 3 SOD =_ 788$,N_SQ. FT. � , �'.�"\ R'.�. �� :� u'j�j, w / � O f $. A'P roo �`9�•Ai9�' , w� 4 pA ,yro. {509.6Q'} � . 0 p� � c�9�+�6`����.0 � � � � � � . �oT s �'•� \ �8 e�acx 3 .y,, ` \ �� �6 2 ss8�., � � 2,F6 f /� � ��i 5aa°�4 rV ;;,. � � 6� '±i;- �Oyr ��D�� �� - , 2��f ���. V' � `� � :�1� . \:,�, ..^pP ;. ?0 Q r� � , �," �'%���� -.i., ..� : �i. �� LOT 7 Q �� �. �. '?; �Ot, \'�'+}....'� ' �nj� BLOCK 3 y �: ... . . ; _ 9,p /� :: ;;::, � �y4 � 2#�y. Gj (`���` '`.?p+ .�`L1l �l �� Ai ' �' �W.N � .- /-�9 T •• •. 'f} •crnn1A ��r(1� \ ',r� t �s\ V '�� � �� 5q�a1" � (ioa.aa') � �5 4•99 NOTES: C.OT GRADtNG T1PE = A � _�>cie `5\ PROPOSED PAD ELEVATION = 109.6' ._ ��O�AJ FRONT SE7 BACK = 22' SlDE SET BAGK = 7.5' REAR SETBACK = 15' C RVE C7ATA � PROPOSED: CURVE RADIUS ARC CHORD BEARWG DELTA LOWEST FLOOR ELEVATIONS: C751 277.00' 105.44' 104.80' N 35'S8'40'" W 21'48'32" l.lVING AREA: 110.30' DESCRIPTIG►N: GARAGE AREA: LO7 9, BLOCK 3, MAP OR PIAT ENTITLED "SILVERADO RANCH SUBQlVISIQN ELEVATIONS REFERENCED TO NQRTN AMERICAN VERTICA� PHASES 2, 3 & 4", AS RECORDED IN PI.AT 800K 73, PAGES 59 THROUGH pATUM OF 19$8. MEAN 5EA 65, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL N0. 12Q230 0455 D EFFECTIVE DATE: 09/30/1992 Project Number: _�___ Square Feet: 9887.05 t LENNAR HOMES � LEGEND; (C)= CALCULA7ED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, �= CENTERLINE, A/C= AIR CONDI710NER, B/C= BACK OF CURB, C/S= - CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARWG, CLF= CHAIN UNK FENCE, CONC— GONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, FjG= PENGE CORNER, FCM= FdUND GONCRETE MONUA9ENT, FIP= FOUNd IROR! PIPE, FIR= FQUND lRON R{}D, FN&0= F4UNd NAIL & DtSK, FPP= Fdt3ND PINCHED PIPE, LFE= LOWEST FLOQR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, P8= PLAT BOOK, PCP= PERMANEN7 CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF�WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & GAP No. 4493, SN&D= 5ET NAIL & DISK, TBM= TEMPORARY BENCHMARK, U P= U71LlTY POLE, W F= WOOD FENCE R = RADIAL JOHN R.BEACH&ASSOCIATES, INC. Drawn ey: � • 8MS SURVEYORS AND MAPPERS Checked By: 911 WEST ST PETERSBURG DRIVE �Rg ONE OLDSMAR, FLORIDA 34677 WAY (g13) 854-1276 FAX (813) 855-8370 Scale: ���W30' AtOT VA�ID tNITHOUT TNE SIGNATURE ANd Dote; P�OT P�AN 12J28ji6 ACS � �� 7HE ORIGINAL RAISED SEAL pF A FLORIDA JOHN BEACM • D TE L.ICENSED SURVEYOR AND MAPPER FLORIDA . LAND SURVEYOR No. 2984 L #4493 Revisions; REVISEQ PER FRQN7 SETBACK 3j07/2017 GH _ ' SKETCH ONLY SEC. 05 , TWP. 26 S, RNG. 21 E. PLOT PI..AN NOT A BOUNDARY SURVEY LOT 9, BLOCK 3 BEARING BASIS: SILVERADO RANCH SUBDIVISION NORTH BOUNDARY OF SE�/i aF tl5-26-21 BEING N 89'25'01" E PHASES Z, 3 8C q- � T THIS SURVEY IS SUBJECT TO ANY FACTS THAT PASCO COUNTY, FLORIDA. j� MAY BE DISCLOSED BY A FULL AND ACCURATE 71TLE SEARCH. ALSO SUBJECT TO SETBACKS, Oi�1 LOT AREA C�4LCULATIONS EASEMENTS AND RESTRICl10NS OF RECORD. LOT = 9887-05 SQ. FT. „�� UNDERGROUND FOOTER, SIEM WALL, AND LIVING AREA = �5�Z SQ• FT- UNDERGROUND UTILITIES ARE NOT LOCATED OR EN'fRY = 38 SQ. FT � SHOWN_ GARAGE = 611 SQ. FT. - COVERED LANAI = �8� SQ. FT. � DO NOT SCALE THIS PRINT_ DIMENSIONS AND PA110 =�A SQ. FT. � NOTES TAKE PREFERENCE. CONC. DRIVE = 554 SQ. FT. N A/C & CONC PAD = 13 SQ. FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND PRIVATE SIDEWALK = 5� SQ. FT. PAGE INDICATES THAT PLAT IS IN IMPERVIOUS = 3� % PREIJMINARY STAGE AND IS SUBJECT TO = 2960 gQ, �, CHANGE AND/OR REVISION. SOD = 692� SQ• FT• CERTAIN DATA SHOWN HEREON BASED ON OFF LOT AREA CALCULAT70NS ENGINEERING PLANS PROVIDED BY CIJENT. RIGHT OF WAY = 7959.52 SQ. FT. S7RUCTURE 71ES SHOWN HEREON DENOTES DRIVE APRON = 350 gq, �. MEASUREMENT FROM FORM BOARDS/FOUNDA710N PUBIJC SIDEWALK = 597 SQ. FT. TO PROPERTY LINE. SOD = 1013 SQ. FT. * = 10' UTILITY EASEMENT TOTALS AREA = 11846.57 SQ. FT. DRIVEWAY = 904 SQ. Fl: SIDEWALK = 6� SQ. FT. SOD = 7940 SQ. FT 1 PRELIMINARY DRAWING: =� 'fHIS P LAN IS FOR PERMITf1NG PURPOSES ''� ONLY NOT FOR CONS'(RUCTION_ VERIFY o LOT 3 ALL DIMENSIONS BEFORE ANY CONSTRUCl10N. �' � BLOCK 3 LOT 8 �� LEGEND: BLOCK 3 � c,���- / _��= PROPOSED DRAINAGE FLOW (00.00) = PROPOSED GRADE ����: / E-00.00 = EXISTING GRADE 11$5� ' � . � . 0 22 � �� }9�2 � '�'� (tos.so•) � 6A� LOT 2 � s BLOCK 3 _.\ � � � . r� R7o �o �j��' � � -..al ,o '9 st9,, i ' �: � ��N. 'AQO ^�a61.-' - �' � i \ O \ • �,9 �,��� }^ . (109.60�) 'p 9• 0 - O . . l 5 � ::'� - :� \ �<<9F�`�j q� � •� ��,:., \ O�� �� 92 - i I � �n�� 'r� ctir •"'2, •• � y rr p:.e�, � \ `�3,8. '- . � s�'\�s � � �JJ' . \ �`L- � p �.•.' � 29 0' �9�`ry li � \ . 'L;C','. � aO9C� '���� Q�`� - �:.�.+�s,+ o. � � �. :��-,�.:�:�-:*;:�;::° ��o;. ��.�o � �s.- .,; . . , ��.,�a. �o � - :.�.-"? ; ��' ' . � j .A .�f ,':l�` . � G�� 'µ'r4� � .���. .o ' .2 �� a "9,PF �/\ � ••�' }�r�,0� .z .AR�' � LOT 10 J \ �u:N . BLOCK 3 N �T .. N.� � � N . M y � _ �b � T� � _ '£� NOTES: � ��':�,. : LOT GRADING TYPE = A ��`+ � 47° PROPOSm PAD ELEVA710N = 109.6' � � �554 � (toe.aa') N � q,99 . FRONT SET BACK = 20' N DESCRIPTION� SIDE SET BACK = 7.5• ^ LOT 9, BLOCK 3, MAP .o�,A ':� REAR SETBACK = 15' � OR PLAT ENTITLED �AJ . PROPOSED: � "SILVERADO RANCH \ ' �^\ LOWEST FLOOR ELEVATIONS: SUBDIVISION PHASES 2, 3 LIVING AREA: 110.30' m & 4", AS RECORDED IN GARAGE AREA: � PLAT BOOK 73, PAGES \ •. ELEVAl10NS REFERENCED TO N 59 THROUGH 65, OF THE NORTH AMERICAN VER7ICAL = PUBLIC RECORDS OF d CURVE Rnotus nRc CHORD BEARING oaTn - DATUM OF 1988. MEAN SEA = PASCO COUNN, FLORIDA. c�si 277_00' 105.44" 104.80' N 35'SB�ao� w 2ras•sz� LEVEL= 00.00 FT. U � APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL N0. 120230 0455 D EFFECTIVE DATE: 09/30/1992 , o LEGEND: � (C)= CALCULA7ED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, g= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= � CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CL.F= CHAIN LJNK FENCE, CONC= CONCREfE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM�T= EASEMENT, N F/C= FENCE CORNER, FCM= FOUND CONCRE7E MONUMENT, FlP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED � PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, P8= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT o REFERENCE MONUMENT, R/W= ftIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, 7BM= iEMPORARY BENCHMARK, � U P= UTILITY POLE. W F= WOOD FENCE R = RADtAL Drawn By. S uare Feet: 9887.05 f LENNAR HOMES � JOHN R.BEACF!&ASSOCIATES,'INC. sMs q � SURVEYORS AND MAPPERS - > 977 WEST ST. PETERSBURG DRIVE Checked By. j ONE OLDSMAR, FLORIDA 34677 JRB � WAY (g�3) 854-1276 FAX (813) 855-8370 Scale: 0 1"=30' •� NOT VAIJD WITHOUT 11iE SIGNATURE AND Date: PLOT PLAN 12 28 16 ACS �2 I�I�r� �o THE ORIGINAL RAISED SEAL OF A FLORIDA JO BEACH ATE N LICENSED SURVEYOR AND MAPPER F RIDA G. LAND SURVEYOR No. 2984 LB�4493 / Revisions: i� - � ! � f � ,r � .'�' � ' v� :` ,.�1? � �, ' ' ' � , '� V - �. .� 4• � _ � y'� - � �ti . , p� Dc �1 (� �- � l 1e-, a � '�F=1�9.fi0 , " 1� i �� ��' g� FF=1Q9.90 FF=1,09J0 � �� `'� c. 2� � '. ��- tOT 12 . � .��� . `'o-, LOT 2 ��T 1 ;�� -- �" J � � ' � j P�108.9 �, �.� � C� � �� „Pu�]_�1��� G�1 � PAD=109.0 � „fs'• ! � ; �� ,r , �b°� � � .as � g. v� "k, py -L1�� `fi TYPE A :`\ � t • ,� � �ie- l, �• ' t� � � FF=1 4+4T�0 - - �O � . • 4+4 `� �1'� \ � \ r f r •._:� �- c- . � LOT 9 \ � • � m �� s- ��. � � ,s- � � PAD=109.6 y� �ti� ,�• � ��.�r r 9-� �,� j • .�111..� �\ �\ TYPE A , `, \� � \ . ir Mi � � � r 110. � f� ,ce• � R ! FF=1�9.50 i 1 ' � - `j � t Y \ b, :` `�'• ,S m• Oza• L0.�j�� 1 1 ��, ��� � -� . �• �'� � � � ti �� '" � � to `' ••.\.� � `� . 6• _ � p��108-�1z' r�O �i B 4� � C G��: �'` ��i �0 , O� G.� ` �j1� .ti . �,. 6- �� ,� PE a , � ��° , =„a , a�- , � -..����� g� �6 � ° s , . �-' � �or_�� g- o� �' �� �� �� .�° ,�� o,;� . �t" - � PAD=:110.0 �� -1 �- o � 6• � TYPE A o F�=110_30 , : r � . E- �' c� ,•' � __ � s;` � LOT 13 � ����' i1� � _20 � , _--�i-'" � -. t `� FLOT10.80 FF=�10.60 PA�E�A 6 �t a`�' °,.r �,��, _ r �"° , FFo108�+� i � � � `�.\ PAD=110.1 PAQ=109,9 � `� l t �� w f �f Ta+S. r � p '� ` TYPE A TYPE A � \ , � PAD=T ,� �. , � �' , t? � �s-a-; TQ�P� • � o : b . �,-, , �. ,, c ,� � � �� � � � ^ � ti .P,� `. � ,� - �, �� � '� �p � 4 J p0 fo �� p 1 '1 - t ,�o *.-� e ;O�`(�� a.�1 s .� ___ ��7 'r -_�O t�O Qk� ''� ,\4 ,� $ � �=. .� _ �� `�J'V C�a r'. �� 'r� � 1 O 6 �` r„� ' i � G �� � 1-_ ;{�v !�`'� _�f68_33+ '� .'\� ' '� °� ���'�.n 2D" DR.4II�IAGE FASEINENT L p� � � pQ it `7 0'�1l77 �_'-__--' � ,`O �'� '�L)tz,��\ -�----(�-�----- �8 ,4. � 'EAScMENT 1 6--9' �z (1 z�' � l°6• .a1 r.�G•n � ; � � ' _'��\ , ' a�1 �__ �� `. � ��os.ao ` 3� -� � -r .J ' � � . �� �� � • F 9 �� � 1 � �S! • __ n r..'V r' ---��� ` �'�' �a- =108.1 _� $ - � „" . �- � s �P E B .�� � _ ' , `. ` `�v 1 .�a---��1,� � _ - 1O 1 _ _� �. � U6 2`"---�� '� `` = `F T,� , =��� '•� 1 _ ,'`9 �td..l2<� -____ � � •• '' �� - � CP� � � ' c�� �� Q , P - `�` -- �� ��' _ p�fEp,--L_� - -"�I' -'__- � �' �'r ` r FF'=1Q9.Q� 7'(88_8 � - . FF=1Q9.90 r1 ,3- Q �� '' __ • LOT 1 \ , r '_• '�5� L T� PAD=109.2 <�' � A PA4-�;tl8.3 FF=7�9.20 �-"FF=1 10.7 D ��� � FF=1 t fl.2 FF=11 a.50 LOT 2 �"PE 8 1� ' ., �° � SS" 1<' 3' TYPE��... , L T 7 ti FF=110.50 FF=110_3a.� � .,,'1 _�•• 50 _ ��� � fo LOT 6�y.�' LOT 5 PAD=109.4 � � �s A PA�-108.5 -.PAD- 69.5 LOT 4 LOT_-3"� ' � '�� -.��� ' �STYPE B _ • ��B PAQ=N$9�8 PAD=!�9.8 PAQ=109.6 7YPE B c, _,�0�' °J� �� %� .�;,,,- � ,- �•, ��� IYPE �'I TYPE B �C��J ` ��O �, c '.\r��,�, "��� �', '��G�-` ` 1" 1 1 107. d- �'\ r����' r is• �_ " ' - - ------ -- � � � -� s ��"m°" �'C'T` �� .. _...•• �•- e �1\6 •\ Y o y `;l s' 7 • � C `� �O� 1 ' ` f � 1 Y�ts��`\���\ �:,12, .s'` T 1O T� _+1^ �� r �.O ,�(`-1'�.CJ� ' V �8,(87. _ � . _ •• /o \ e'67u oy � 1C . • •. \�� �� �� `�C. '_ - _ T _ _-`''__ _ TX ' ' _' " {` • �& ` WETLAND ��'°.���.�. ',� - . . - _ �� , -�� ,�.� _c � CONSERVATION � ������ _ r _ � -�g \4�'�, �, .� `` . .�� a. �1Y . ' �-�t�at=ro-e•Bt AREA P �� �� �� �a� � �� �„- _,.� i- .���°����-� _ , ,- . . �.. �. � 11' 11• • � T��7' � .�,__ �` a�h . � . (1 .22 1/ / L V. _, - "_� _" ••� �i 5 ��\\ ` �'`` � �'�' 7�''� •y','�,�_� 6-� PI�'P������p7�� .'�� �'��SWtLu�,�� / . _ � ' ��NL � o � \ ��- �c � � �- �� � � Dc .• 9-e• r i s r�r .-r ,� � . 100YRDHW=104.0 __ __ ___ . CONTROL STRUC7UR�C �eo�s• � � \O � .' " •� a�i- o,•�%���- , _. _ .,�� - • . � _ • -- .•-_ -- -- _ �' � � ���a` r � 9-,�"� E'� e C �'''�\ 's�� c - ' �` cS ,� _ -:s S i � �'o•� „- � �� ,., . . _ . - - - - -- - ---------. . _ . _ _ � . p pprC r � s ,. - -- - .._ p �_ S "_-___ '4L • ._•.-'���_�'_ UD �\VUDLL ' "�� .__' �� .- � - OS-2b-21-0070-00300-009Q � Pasco County Praperty Appraiser Page 1 of 1 I � !�„ fll,/ ��y .t Data Current as Cif: Weekly Archive - Saturday, Aprii 15, 2017 Parcel ID 05-26-21-0070-00300-0090 (Card: 001 of 001) Classification 00 - Vacant Residentiai Mailing Address Property Value DUNE FL LAND I SUB LLC Ag Land $0 C/O HAWK MANAGEMENT CO LLC Land $26,783 2502 N ROCKY PdINT DR STE 1050 Building $d ROCKY POINT FL 33607-5995 Extra Features $0 Physical Address 6564 PADEN WHEEL ST ZEPHYRHILLS, F�33541 ]ust Value $26,783 Assessed (Non-School Amendment 1} $26,783 Legal Description (First 4 Lines) SI�VERAD{� RANCH SUBDIVISIQN � PHASES 2, 3 &4 PB 73 PG 059 Taxable Value $26,783 I BLUCK 3 LOT 9 Jurisdiction CitY of Zephyrhills C�and Detail (Card: 001 af 001) ___._�_.�.�-----. ___.______. __ _.� _ _ ..� _.. ____. .�._. _ Line �Use Description;Zoning Units rType jPrice ;Condition ;Value ----- ...__�_._________;__.__.._._�..._. ..— -._____.__�___-�-- _____ �__�.___.___--,—__ __ 1 ' Q100 SFR __,�_._ MPUD 6,OOO.QO � SF _�-_-_$4.25 � 1.00 ' $25,504 --_z_.__.�� 01Q0 ^��- SFR---_�-__ MPUDi� 3,887.00 � SF ; $0.33 ; 1.00 � $1,283 Additiona[ C.and Informatian —_____.____. ------�__--. -_--------_.,____._____.__.____�_ __----- '__._..�___..___,___.�_ ____._._ . _ ---- Acres I 0.23 j Tax Area i 30SI � FEMA __ �Residential Code SLVRLPI � Code Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Peatures (Card: 001 of OOi} _—__._._._�__-----_._.--.___�__._�.___ ��_.._____.________.______�__.._---------__._._. Line �Descr�ption �jYear J� EUnits_� � iValue �Yu�^T._ _____.------- _ _�__— —__._ _ No Extra Featuras Sales Histary - See All 5 sales � Previous t.�wner: - - - _..� _�..��____.---,_ .�.__...__.��._..__ .___-.---�.--- _ __.____...w____.__.._.�_.....,._�._�—;.._.�,________.--- - ._. .__.�.___________.__ _ Month/Year �Book/Page_ ____jType _ __ DOR Code`ECondition__�Amount 09J2011 � 8605 / 3376 � Warranty Deed Y_�vV�05 � Vacant � Multi-Parcel Sa(e ...__.__-".......�_..._�__ �........�_._.�.�_.->..._�'__._......E... ___"'__"_.�.�.�_.���___.,._....r.�_.._....-..I_...._..__.__-.�.,-,__-��. '__��___,w���-� 05/2010 � $373 / 1912 � Certificate of Title,� 12 �_�__Vacant__ ;� _ $0 �07/2005 � 6725 / 1059 � � Quit Claim Deed j i Vacant � $0 http://search.pascopa.com/parcel.aspx?sec=05&twn=26&rng=21&sbb=0070&b1k=Q030Q... 4/20/2017 i .: � �;� - _ � � � � � � �: pAsco coutv-r�r; F�o��aa I . ' Permtt No. � .,�''l � � Date Permifted i / Huilder NamelQwner Name �2P+-tt�' �� Controi# . ounty Parcef No. �-�—Zl���Q-Dl>3DD^DO�U SubDiv: �l� ` ;ddress/�ocation tt�J �LI��P'1 �t�'!�[��l `sr � � � t , � IassificafiontType of.Use �! e r RANSPORTATIt3N IMPACT FEE . Rate: Sq Ft Unit: � � �xempt ❑Yes ❑ No Now Determtned . � `mpact Fee Amaunt $3�(o �2.t?t� Zone Na. TAZ: 'SCHQOL IMPAGT FEE Account {456) Si�gte-Family qetached Fiouse Amount $ � 7�. Z-� ' (057) Mobile Home (058} Ot�er Residentiat • - 123) Coflectfan Fee ` Exempt [�Yss � No iiaw�Qetermined � � t� � PARKS'AND RECR�ATtON FEE �'�~ � and Account Lartd Credit �Land Tota! ! .�.�_._ . .. �• ecreatian Account Recreation Credit „� Recreatton Total ___�_.__ ! - � I one • TOTAl.AMOUNT $ � � 'J� IExernpt ❑ Yes (� Na Haw Determfined ' � L[BRARY FEE , ( �.and Account Land Credit - Land Total i - �acility Account Facillty Credit Facility Totat , �xeinpt ❑Yss ❑ M1fo How Determined Total Amount���� �tES01lRCE FEE ERU � 'CdTAL�AMOtlNT ' Prepared By Checked By � i I ' I NO CERTtFiCATE OP OCCUPANCY W!L!BE ISSU.Ep OR FINAL INSPECTION � PERFORMED UFfTiL 7HH TOTAL AMpUNTS l.ISTED HAVE � BEEN PAId AND ' RECEIPTED FOR BY A CEt�lTRAL PERMITi'INfa OFPICE�OF PASGO GOUTlTY �j � knowledgement befaw doas not impiy acceptance of concurrence�but simply recelpt of a copy of this fartn, lacing the building permlk owner on notice of this assessment antl tha conditions of payment for same. I I' � � I I DATE ��T RECEIVED BY RECElPT NO. DATE i BY { � � � ` � Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. ' 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. '' 4. Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. 9. No electric,plumbing, mechanical, or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. All 2008 N.E.C. Codes will be enforced. 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 22. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. F.F.E.-Finished Floor Elevation F.B.C-Florida Building Code 5�'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2008) �� T '� FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 3127 sf ADS Builder Name: LENNAR HOMES street: 6564 Paden Wheel Street Permit Office: Cl o Zephyrhills City,State,Zip: ,FL, Permit Number ����' Owner• LENNAR HOMES Jurisdiction: 611600 Design Location: FL,Tampa 1 New construction or existing New(From Plans) 9 Wall Types(2907.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ftZ b.Concrete Block-Int Insul,Exterior R=4.1 1309.80 ftz 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ftz 4 Number of Bedrooms 5 d.N/A R_ ftZ 10 Ceiling Types (1946.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1772.00 ftZ 6. Conditioned floor area above grade(ftz) 3127 b.Knee Wall(Vented) R=30.0 174.00 ft� Conditioned floor area below grade(ftZ) 0 c. A R= ft z 11.Ducts R ftz 7. Windows(366.3 sqft.) Description Area a.Sup•Attic,Ret:1st Floor,AH:1st Floor 6 585 a. U-Factor Dbl,U=0.54 162.68 ftz b.Sup• Attic,Ret:2nd Floor,AH:2nd Floor 6 545 SHGC• SHGC=0.31 b. U-Factor� Dbl,U=0.56 117.00 ft� 12.Cooling systems kBtu/hr Efficiency SHGC• SHGC=0.28 a.Central Unit 25.2 SEER:16.20 b.Central Unit 25.2 SEER:16.20 c. U-Factor Dbl,U=0.56 86.67 ft2 SHGC� SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor� N/A ftz a.Electric Heat Pump 21.8 HSPF:9.00 SHGC: b.Electric Heat Pump 21.8 HSPF:9.00 Area Weighted Average Overhang Depth: 4.213 ft. Area Weighted Average SHGC� 0.303 14 Hot water systems a.Electric Cap:40 gallons 8. Floor Types (1772.0 sqft.) Insulation Area EF•0.950 a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ft2 b. Conservation features b Floor over Garage R=11.0 '260.00 ftZ None c.N/A R= ftZ 15.Credits Pstat Total Proposed Modified Loads: 91.14 PASS Glass/Floor Area: 0.117 Total Baseline Loads: 90.86 I hereby certify that the plans and specifications covered by Review of the plans and ��'���T.q�, this calculation are in compliance with the Florida Energy specifications covered by this �4, . '" w,- ,��j Code. calculation indicates compliance �'��rf,��''' , ,:_`�4,r.� ti�+'�'` �ave ���G� with the Florida Energy Code. � rarrr° �''� •--��';�Y,��'�,c„ti O PREPARED BY: Before con`struction is completed v� �:-, '�'"�� '`"_" ''�t-�' DATE: this building will be inspected for � ' -' 7=�` _ ;� �'�--�.:.. compliance with Section 553.908 ,, • � � I hereb certi that this buildin as desi n , is in com liance Florida Statutes. } . : ` � .�. Y fY 9, 9 P �1+ ' �s: . with the Florida Energy Code. `�''Ojj ySrg''�� OWNER/AGENT: BUILDING QFFIL�I � DATE. DATE. 'L'4� - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. 1/3/2017 12:24 PM EnergyGauge�USA-FlaRes2014 Section R405 4 1 Compliant Software Page 1 of 5 �� , .\ f � FORM R405-2014 PROJECT Title: 3127 sfADS Bedrooms: 5 Address Type: StreetAddress Building Type: User Conditioned Area: 3127 Lot# Owner• LENNAR HOMES Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: LENNAR HOMES Rotate Angle: 45 Street: Permit Office: Cross Ventilation: No County� Pasco Jurisdiction: Whole House Fan: No City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE � / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Block1 1512 14061.6 2 Block2 1615 12920 � SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 1st Floor 1512 14061.6 Yes 1 1 1 Yes Yes Yes 2 2nd Floor 1615 12920 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 173 ft 0 1512 ft2 ___ 0.3 0 0.7 2 Floor over Garage 2nd Floor ____ ____ 260 RZ 11 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1982 ft2 0 ftZ Medium 0.85 N 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1772 ft� N N 1/3/2017 12:24 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 2 of 5 f � FORM R405-�014 GEILENG # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floar 30 9772 ft2 0.1 Wood 2 Knee Wall(Vented) 2nd Floor 30 174 ft2 0.11 Wood WALLS t Adjacent Space Cavity Width Height Sheathing Framing Soiar Belo w 9 N=>NE Exterior Concrete 81ocic-Inf Insul 9sf Ffoor 4.1 7 6 9 4 70.0 ftZ 0 0 0.6 0 2 N=>NE Exterior Cancrete Block-Int Insul 1st Floor 4.1 12 6 9 4 116.7 ft2 0 0 0.6 0 3 E=>SE Exterior Concrefe B(ocEc-int tnsui 1 st Fioor 4.1 45 4 9 4 423.9 ft2 Q Q 0.6 0 4 S=>SW Exterior Concrete Block-Int Insul 1 st Floor 4.1 14 4 9 4 133.8 ft2 0 0 0.6 0 5 W=>NW Exteriar Gancrete B1ocEc-int Insu!1 st Fioor 4.1 4 0 9 4 37.3 ft2 0 0.8 0 6 S=>SW Exterior Concrete Block-Int Insul 1 st Floor 4.1 25 B 9 4 239.6 ftz 0 0.6 0 7 W=>NW �terior Concrete Block-int insui 1 st Floor 4 1 31 0 9 4 289.3 ft2 0 0.6 4 ,,,_ 8 N=>NE Garage Frame-Wood 1 st Floor 11 19 4 8 0 154.7 ftz Q.23 0.01 0 „�9 W=>NW Garage Frame-Wood 1 st Fioor 11 6 B 8 0 53.3 ftz 0.23 O.d1 Q 10 NW=>N Exterior Frame-Wood 2nd Floor 11 7 6 8 0 60.0 ft2 0.23 0.6 0 11 N=>NE Exterior Frame-Wood 2nd Fioor 11 29 A 8 0 234 7 ftz 0.23 0.6 0 12 NE=>E Exterior Frame-Wood 2nd Floor 11 7 6 8 60.0 ftZ 0.23 0.6 0 13 E=>SE Exterior Frame-Wood 2nd Floor 11 44 8 8 357.3 ft2 Q.23 Q.6 0 1R S=>SW Exterior Frame-Wood 2nd Floar 11 40 8 320.0 ft2 0.23 0.6 0 75 W=>NW Exteriar Frame-Wood 2nd Flaor 11 44 & & 0 357.3 ft2 0.23 0.6 0 , DOORS # Ornt Door Type 8pace Storms U-Value Width Fieight Area Ft In Ft In 1 N=>NE tnsulafed 1st Floor Nane .2 3 6 8 20 ft2 2 N=}NE Wood 1st Floor Nane 4 2 8 6 8 17.8 ftZ WINDOWS Qrientation shown is the entered arientakion{_> changed to Worst Case. ` Wa�� flverhang V # Ornt ID Frame Panes NFRC U-Factar SHGC Area Depth Separation Int Shade Screening 1 '.1U->NE 'I Metat �ow-E Doubte Yes 0.56 0.28 7A ftZ 6 ft 0 in 'i ft 0 in None Exferiar 5 2 N=>NE 2 Metal Low-E Double Yes 0.56 0.28 32.0 ftZ 1 ft 0 in 11 ft 9 in None E�tterior 5 3 E->SE 3 (l+letal Low-E Dou61e Yes d.54 Q31 23A ft2 1 ft 0 in 11 ft 9 in Drapeslbti�ds Exterior 5 4 S=>SW 4 Metal Low-E Double Yes 0.54 0.31 23.0 ftZ 1 ft 0 in 1 ft 6 in None Exterior 5 5 W=>NW 5 Metat Low-E Double Yes 0.56 0.32 33.3 ft2 25 ft 8 in 1 ft d i� None None 6 5=>SW 6 Me#al Low-E Double Yes 0.56 0.32 53.3 ftz T ft 0 in 1 ft 0 in None Exterior 5 7 W=>NW 7 Metal Low-E Double Yes 0.54 0.31 32.R ft2 1 f#0 in 91 it 0 in None None 8 NW=>N 10 Metal Low-E Double Yes 0.56 0.28 16.0 ftZ 1 ft 0 in 0 ft 8 in None Exterior 5 9 N=>NE 14 MetaI Low-E Double Yes 4.56 fl28 46A ft� 9 ft 0 in 1 ft 0 in Drapesihlinds None 10 NE=>E 12 Metal Low-E Double Yes 0.56 0.28 16.p ftz 1 ft 0 in 0 ft B in Drapes/blinds None 11 E=>SE 13 Metal Law-E Double Yes 0.54 �.3'[ 6.7 ftz 1 ft 0 in 0 ft 8 in Drapestb{inds None 12 5=>SW 1A Metal Low-E Double Yes 0.5R 0.31 69.0 ftZ 1 ft 0 in 0 ft 8 in prapes/blinds None 13 W=>NW 15 Meta! Low-E Double Yes 0.54 0.31 9.0 ftz 1 ft Q in 0 ft 8 in LlrapesJbli�ds None 1/3/2p17'12:24 PM EnergyGauge@ USA-FlaRes2014 Sectian R405.4.1 Compliant Software Page 3 of 5 r 5 FORft/I R405-2014 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation � 1 611 ft2 260 ft2 72 ft 9.3 ft 1 INFtLTE2AT[ON # Scope Me#hod SLA CFM 50 EtA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000274 2248.5 123.44 232.14 .2531 5 HEATING SYSTEM # System Type Subtype E�ciency Capacity Block DucFs 1 Electric Heat Pump None HSPF:8.9999 21.8 kBtu/hr 1 sys#1 2 Electric Heat Pump None HSPF:9 2i.8 kBtulhr 2 sys#2 COO�ING SYSTEtVI # System Type Subtype Efficiency Capacity Air Fiow SHR Block qucts 'I Ce�ttal Unit Split SEER:16.2 25.2 kBtuthr 758 cfm 0.85 f sys#1 2 Central Unit Split SEER:16.225.2 kBtu/hr 756 cfm 0.85 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Eleckric None Garage 0.95 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SY$TEM FSEC Coitector Storage Cert # Company Name System Model# Collec#or Model# Area Valume FEF None None ftz DEICTS / —Supply— ---Retum— Air CFM 25 CFM25 HVAC# V # �aca#ion R-Value Area �ocation Area �eakage Type Handter TOT OI1T QN RL.F Heat Cool 1 Attic 6 585 ftZ 1st Floor 155 ftz Prop.Leak Free 1st Floor —cfm 45.R cfm 0.03 0,60 1 1 2 Attic 6 545 ftZ 2nd Floor 185 ftz Prop.Leak Free 2nd Fioor —cfm 48.5 cfm O.d3 0.80 2 2 1/3/2017 12:24 PM EnergyGaugeCRl USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 � , FORM R405-2014 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb ]Mar A r Ma X Jun X Jul Au X Se Oct Nov ]Dec Heatin9 f X�Jan f X�Feb f X]Mar f �APr f �May 4 �Jun 4 �Jul ��Aug 4 �SeP f �Oct f X�Nov f X]Dec Ventin [ Jan [ Feb [X]Mar [X A r [ Ma [ Jun [ Jul Au [ Se [X Oct [X Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 76 78 78 78 78 78 78 Heating(VVD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 66 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 1 -Electric Heat Pump 0% 1 -Central Unit None 0 0 0 2-Electric Heat Pum 0% 2-Central Unit 1/3/2017 12:24 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) � DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index,the more efficient the home. „ FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 1309.80 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ftz 4. Number of Bedrooms 5 d.N/A R= ftz 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area a.UnderAttic(Vented) R=30.0 1772.00 ftZ 6. Conditioned floor area(ftZ) 3127 b.Knee Wall(Vented) R=30.0 174.00 ftz 7 Windows'* Description Area c.N/A R= ftz a. U-Factor� Dbl,U=0.54 162.68 ft� ��•Ducts R ftZ a.Sup•Attic,Ret:1st Floor,AH:1st Floor 6 585 SHGC: SHGC=0.31 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 545 b. U-Factor: Dbl,U=0.56 117.OD ftZ SHGC� SHGC=0.28 12.Cooling systems kBtu/hr Efficiency c. U-Factor• Dbl,U=0.56 86.67 ft� a.Central Unit 25.2 SEER:16.20 SHGC• SHGC=0.32 b.Central Unit 25.2 SEER:16.20 d. U-Factor N/A ftZ 13.Heating systems kBtu/hr Efficiency SHGC' a.Electric Heat Pump 21.8 HSPF:9.00 Area Weighted Average Overhang Depth: 4.213 ft. b.Electric Heat Pump 21.8 HSPF:9.00 Area Weighted Average SHGC� 0.303 8. Floor Types Insulation Area 14.Hot water systems = a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ft EF:0.95 b.Floor over Garage R=11.0 260.00 ftz b. Conservation features c.N/A R= ftZ None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building T�1ES� Construction through the above energy saving features which will be installed (or exceeded) o� .. � `�r� .y,.,, , ^y` O� . in this home before final inspection. Otherwise, a new EPL Display Card will be completed k3', r% =w= �� ,�, - � „ r based on installed Code complia t features. ' �,,,,,';�>t;,,>;,��;;.��;,;.�, p� Builder Signature• � Date: O1/18/17 � ��;��- ..+ `� �� * , � . � Address of New Home� 6 64 Paden Wheel Street City/FL Zip.Ze�hyrhills, FL 33541 '�. ' S� Cp��„�,i1. . *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site,at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. ""Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/3/2017 12:26 PM EnergyGauge�USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Buildin Anal sis Job: 3127sf g Y Date: 1/3/2017 lowerfloor By: DaveAldrich Bayonet Plumbing Heating and Cooling 6950 New York ave,Hudson � • ' � • ' For: Lennar Homes ! - • s • • Location: Indoor: Heating Cooling '' Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ftz Btuh % of load Walls 5.5 6963 28.8 Glazing 30.2 6158 25.5 Doors 23.5 466 1.9 Ceilings 1.3 281 1.2 Floors 3.8 5699 23.6 Infiltration 1.9 2752 11.4 Ducts 1852 7.7 ,� Piping 0 0 Humidification 0 0 Ventilation 0 0 m. Adjustments 0 °` Total 24170 100.0 � • r Component Btuh/ftz Btuh % of load Walls 2.8 3512 18.2 w ^�°•^• Glazing 44.3 9039 46.9 Doors 18.4 365 1.9 Ceilings 1.8 386 2.0 Floors 0 0 0 d Infiltration 0.4 595 3.1 ' D ucts 2136 11.1 Ventilation 0 0 Internal gains 3250 16.9 •� Blower 0 0 � °°"' Adjustments 0 Total 19283 100.0 ""° Latent Cooling Load= 2611 Btuh Overall U-value= 0.155 Btuh/ftz-°F Data entries checked. .�, W1'1 f1tS0'�" 2017-Jan-0311:34:04 9 Right-Suite�Universal 2013 13.0.09 RSU05714 Page 1 � H:\LENNAR LOADS\3127 sf ADS 2-2tons.rup Calc=MJB Front Door faces:SW Buildin Anal sis Job: 3127sf g y Date: 11312017 upperfloor By: DaveAldrich i Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson � • ' • B For: Lennar Homes � - • � • • Location: Indoor: Heating Cooling Tampa InternationalAP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ftz Btuh % of load Walls 3.8 4450 28.2 Glazing 30.2 4895 31.1 Doors 0 0 0 - Ceilings 1.3 2026 12.9 `" Floors 0 0 0 Infiltration 1.9 2471 15.7 . Ducts 1914 12.1 Piping ' 0 0 �, Humidification 0 0 Ventilation 0 0 Adjustments 0 �" Total 15T56 100.0 • � • Component Btuh/ftZ Btuh % of load - Walls 2.7 3213 16.3 `��� Glazing 51.9 8414 42.7 Doors 0 0 0 Ceilings 17 2801 14.2 " Floors 0 0 0 / � Infiltration 0.4 534 2.7 ' ' D ucts 2212 11.2 , Ventilation 0 0 Internal gains 2550 12.9 Blower 0 0 "°°°' Adjustments 0 `�'° Total 19724 100.0 Latent Cooling Load=2501 Btuh Overall U-value= 0.098 Btuh/ftz-°F Data entries checked. .., Wri htSOft" 2017-Jan-0311:34:04 9 Right-Suite�Unive�sal 2013 13.0.09 RSU05714 page 2 � H:\LENNAR LOADS\3127 sf ADS 2-2tons.rup Calc=MJ8 Front Door faces:SW Pro ect Summa Job: 3127sf J � Date: 113/2017 lower floor By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson ` e - e s For: Lennar Homes Notes: ADS specs S - • • � Weather: Tampa InternationalAP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 39 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 55 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 22318 Btuh Structure 17147 Btuh Ducts 1852 Btuh Ducts 2136 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24170 Btuh Use manufacturer's data y Rate/swing multiplier 1 00 Infiltration Equipment sensible load 19283 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2234 Btuh Ducts 377 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area(ftz 1512 1512 Equipment latent load 2611 Btuh Volume�ft') 16162 16162 Air changes/hour 0.24 0.12 Equipment total load 21894 Btuh Equiv.AVF(cfm) 64 33 Req. total capacity at 0.85 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox / Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-024230-18 Cond 14HPX-024-230-18 AHRI ref 5186808 Coil CBX27UH-024-230'++TDR AHRI ref 5186808 Efficiency 9 HSPF Efficiency 13.7 EER, 16.2 SEER Heating input Sensible cooling 21420 Btuh Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh Temperature rise 25 °F Total cooling 25200 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.033 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0 in H20 Static pressure Q in H20 Space thermostat Load sensible heat ratio 0.88 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .�. WI'1 htsoft°' 2017-Jan-0311:34:04 �. g Rfght-Suite�Un(versal 2013 13.0.09 RSU05714 Page 1 �� H:\LENNAR LOADS\3127 sf ADS 2-21ons.rup Calc=MJB Front Door faces:SW Pro ect Summa Job: 3127sf � � Date: 113/2017 upperfloor By: DaveAldrich Bayonet Plumbing Heating and Cooling 6950 New York ave,Hudson � • ' 6 ! For Lennar Homes Notes: ADS specs � - • • � Weather� Tampa InternationalAP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 39 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 55 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 13842 Btuh Structure 17512 Btuh Ducts 1914 Btuh Ducts 2212 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower � 0 Btuh Piping 0 Btuh Equipment load 15756 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 19724 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2108 Btuh Ducts 392 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ftz 1615 1615 Equipment latent load 2501 Btuh Volume�ft3) 12920 12920 Air changes/hour 0.27 0.14 Equipment total load 22224 Btuh Equiv.AVF(cfm) 57 30 Req. total capacity at 0.85 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-024-230-18 Cond 14HPX-024-230-18 AHRI ref 5186808 Coil CBX27UH-024230"`++TDR AHRI ref 5186808 Efficiency 9 HSPF Efficiency 13.7 EER, 16.2 SEER Heating input Sensible cooling 21420 Btuh Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh Temperature rise 25 °F Total cooling 25200 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.051 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.89 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. C "�" wrightsoft° Right-Sulte�Universal 2013 13.0.09 RSU05714 2017-Jan-03 11:34:04 Page 2 � H:\LENNAR LOADS\3127 sf ADS 2-21ons.rup Calc=MJB Front Door faces:SW Manual S Compliance Report Job: 3127sf Date: 113/2017 lowerfloor ' By: DaveAldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson � i ' � � For: Lennar Homes • � � e • • Design Conditions � Outdoor design DB. 91.3°F Sensible gain: 19283 Btuh Entering coil DB. 75.6°F Outdoor design WB• 77.3°F Latent gain: 2611 Btuh Entering coil WB. 62.8°F Indoor design DB: 75.0°F Total gain: 21894 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data atActual Design Conditions Equipment type: SpIitASHP Manufacturer: Lennox Model: 14HPX-024-230-18+CBX27UH-024-230'++TDR Actual airflow: 800 cfm Sensible capacity: 21420 Btuh 111% of load Latent capacity: 3780 Btuh 145% of load Total capacity� 25200 Btuh 115% of load SHR. 85% o e e Design Conditions Outdoor design DB• 30.8°F Heat loss: 24170 Btuh Entering coil DB. 69.6°F Indoor design DB: 70.0°F � Manufacturer's Performance Data atActual Design Conditions Equipment type: SpIitASHP Manufacturer: Lennox Model: 14HPX-024230-18+CBX27UH-024-230"++TDR Actual airflow: 800 cfm Output capacity: 21800 Btuh 90% of Ioad Capacity balance: 40 °F , Supplemental heat required: 2370 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow• 800 cfm Output capacity: 7.1 kW 100% of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. .•.. wri htsoft` 2017-Jan-0311:34:04 � 9 Right-Suite�Universal 2013 13.0.09 RSU05714 Page 1 �'�H:\LENNAR LOADS\3127 sf ADS 2-2fons.rup Calc=MJB Front Door faces:SW . , . Manual S Compliance Report Job: 3127sf Date: 1/3/2017 upperfloor By: DaveAldrich Bayonet Plumbing Heating and Cooling 8950 New York eve,Hudson � • ' � • For: Lennar Homes e � e • � Design Conditions Outdoor design DB: 91.3°F Sensible gain: 19724 Btuh Entering coil DB• 75.7°F Outdoor design WB� 77.3°F Latent gain: 2501 Btuh Entering coil WB. 62.8°F Indoor design DB: 75.0°F Total gain: 22224 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data atActual Design Conditions Equipment type: SpIitASHP Manufacturer: Lennox Model: 14HPX-024230-18+CBX27UH-024230"++TDR Actual airflow: 800 cfm Sensible capacity: 21420 Btuh 109% of load Latent capacity� 3780 Btuh 151% of load Total capacity� 25200 Btuh 113% of load SHR: 85% • • • Design Conditions Outdoor design DB. 30.8°F Heat loss� 15756 Btuh Entering coil DB 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data atActual Design Conditions Equipment type: SpIitASHP _ Manufacturer: Lennox Model: 14HPX-024230-18+CBX27UH-024230"++TDR Actual airflow: 800 cfm Output capacity: 21800 Btuh 138% of load Capacity balance: 30 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 4.7 kW 102% of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. � wri htsoft` 2017-Jan-0311:34:04 � 9 Right-Suite�Universal 2013 13.0.09 RSU05714 Page 2 �'� H:ILENNAR LOADS\3127 sf ADS 2-2tons.rup Calc=MJB Front Door faces:SW CITY OF / / / / BUILDINQ ZEPHYRHILLS DEPARTMENT OF ADDITION OR C:ORRECTION � • • - • ADDR����� �(i`L��'' �� D/v�/ PERMIT f� ��G THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. � , ��SS� , , G It is unlawFul tor any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any paR of the work with flooring,lath,earth 780-0020 FOR E- NSPECTI N or other material,un61 the prop'er inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON-FRI. INSPECTOR �'