Loading...
HomeMy WebLinkAbout17-18518 i CITY OF ZEPHYRHILLS 5335-8TH STREET '°' ' (813)780-0020 185,1•8 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL � PERMIT INFORMATION' � LOCATION INFORMATION Permit#:18518 � Issued: 5/30/2017 Address: 6563 PADEN WHEEL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: � Cost: 420,866.52 Total Fees: 12,087.69 Subdivision: SILVERADO � Amount Paid: 12,087.69 Date Paid: 5/30/2017 Parcel Number: 05-26-21-0070-00400-0090 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 15550 LIGHTWAVE DR Address: 4600 W. CYPRESS ST STE 200 CLEARWATER, FL. 33760 TAMPA, FL. 33607-4099 Phone: (727)479-1740 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 3,957 SQ FT APPLICATION FEES BUI DING FEE 1,560.01 ELECTRICAL FEE 326.48 PLUMBING FEE 217.65 MECHANICAL FEE 152.36 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfd100°/a 4,828.00 SCHOOL IMPACT FEE-sfr/1% 4828 TRAFFIC IMPACT FEE 1% 36.32 TRAFFIC IMPACT FEE 99% 3,595.68 t �� .�2��� � t�a � r� � , ���� Ins ections Re�uired FOOTER 2 D ROUGH PLUMB MIS INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. � 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. � DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. j REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the I local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or i first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: �, NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental ; entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney i before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. � NO OCCUPANCY BEFORE C.O. I CONTRACT RS SIGNATURE PERMIT OFFI , � PE MIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER � � � 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 ,� , Building Department Date Received Phone Contact for Permittin 813 363 _ 2891 Owner's Name Lennar Homes,LLC Owner Phone Number g13.574.5700 Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name N�A Owner Phone Number Fee Sim le Titleholder A N/A p ddress JOB ADDRESS 6563 Paden Wheel Street LOT# 0090 SUBDIVISION Silverado Ranch Subdivision Ph 2,3,&4 pARCEL ID# 05-26-21-0070-00400-0090 ✓ � SIGNINED FR�OM PROPERTY T�ncEl DEMOLISH WORK PROPOSED � NEW CONSTR e ADD/ALT INSTALL REPAIR PROPOSED USE � SFR Q COMM � OTHER TYPE OFCONSTRUCTION � BLOCK Q FRAME 0 STEEL � DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF 3g57 SQ FOOTAGE 3�27 HEIGHT 2 StOry � �P'tTTrTI"�"t�TrT 1"1'T' BUILDING $ ��/ C��V VALUATION OF TOTAL CONSTRUCTION b � '�/ IELECTRICAL $ � PROGRESSENERGY Q W.R.E.C. �, ' � ` AMP SERVICE �PLUMBING $ � ,�� ��l ��/ �MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION f�/ � ' " ` '��I �GAS � ROOFING Q SPECIALTY � OTHER I FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA �YES �O i�r u ' -��F-;-'�-'�T4-1-4-4-F-F-:-:-:-F�F-4-F-�--f-F-�-�1-1-�F-Ff-1-��E-i-f--FF4-�--F-E-�-�--E-F-�--��-'�--'�-'r:-:-�--1�F-f-1-F-�{�-4-F-� BUILDER COMPANY Lennar Homes,LLC � SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4600 W.Cypress St.Ste.2 ,Tampa,FL 33607 License# CGC1518166 � I ELECTRICIAN COMPANY Edmonson Electric, �C1C. SIGNATURE REGISTERED Y/ N FEE CURREN Y/N � Address 1034 Skipper Road,Tampa, FL 33613 �icense# EC13005408 PLUMBER ' COMPANY Bayonet Plumbing, Heating &AC, Inc ; SIGNATURE REGISTERED Y/ N FEE CURREN Y/N ' Address P O. Box 5308, Bayonet F 34674-5308 License# CFC042998 � MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, Bayonet, 34674-5308 �icense# CAC058062 OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N - ' Address 4211 Shoal Line Blvd, Spring Hill, FL 34607 �icense# CCC057991 IIIIIIIIItlllllllllllllllllllllllllllllllllllllllllllllllllllllllll RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, � Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects � COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. � '*`"PROPERTY SURVEY required for all NEW construction. ��.'.+'�G�' �',��' 1-1-f..l��l..����� . ...-..-rC„r�• • I��I..��f..l..f�■ •�.,�,•�„r�• • 1..1����1..��1..1..4�I..i�1���f..��f..1..4.1..{�...:.:r'� Directions: Fill out application completely. Owner 8�Contractor sign back of application,notarized � If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) I "" Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(PIoUSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW . , NOTICE OF DEED RESTRICTIOiVS: The�undersigned understands th�t this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- � 8009.� Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended) If valuation of work is$2,500 00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT. I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTIC OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR I Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirme )before me this �u-iviar-i i by paul Sweene Zo-Ma�-,� by Paul Sweene Who is/are personally known to me or Who is�ersonally known to me r as identification. as identification. � Notary Public / 1'� Notary Public I Commission No. FF98537 Commission No. rF98537 Elissa M.Holleran Elissa M.Holleran Name of Notarv tvoed,printed or stamped Name of Notary typed,printed or stamped �,� ' ..���, w ��I��.bH��l�l4�}V' . ', ��IfiSJ�11.Nt�l��l , a �n��n�i'an;MPf��WB97 � C�tr�`��n.t��RB�96�T � p��r�s������,���a ` �fi������,�a�a ': '��, b�,i�l�+r�tasyr�tw���a[�ra��u�' : • dQa��ivtrarr�l"��I�ucn��Y;71�14lI � — �Jv;_ . s'fr��' '4 _ - , I . I . Lennar Homes-6563 Paden Wheel St-3,957 sq ft , yq � � � � SQ. FEET PRICE ' MAIN OR LIVING: 3,957 $ , 106.36 OTHER AREA UNDER ROOF: - $ - 88.00 I - � _ OTHER: _ - $ " - I � - I - - - � - � �VALUATION $ �420,866.52 - � FEE SHEET $ 1,451.00 _ ' ADbRESS $ 40.00 - � DRIVEWAY $ 40.00 - � __ BUILDING: _$ 1,560.02 � ELECTRICAL: $ 326.48 I PLUMBING: $ 217.65 MECHANICAL: $ 152.36 SUB-TOTAL $ .2,256.50- 'fOTAL $_ 2,256:50 SEWER: na , WATER: - -- na � IRRIGATION: $ - � - ' 'FOTAL: $ - � WATER METER: = na IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: na � � INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ � . � I PUBUC SAFETY IMPACT FEES � POLICE $ - 254.00 i FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,809.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 I' �� 1.0% $ 48.28 ', TOTAL: $ 4,876.28 ' T I F'S: $ 3,63200 99% $ 3,595.68 _ _ 1% $ _ _ 36.32 D�� �j �,� � �Z�� , U " "� � TOTAL.: $ 12,0�7.69 `�j � Lennar Homes-6563 Paden Wheel St-3,957 sq ft i � � I o umn SQ. FEET PRICE MAIN OR LIVING: 3,957 $ 106.36 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 420,866.52 FEE SHEET $ 1,451.00 I ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,560.02 I ELECTRICAL: $ 326.48 � PLUMBING: $ 217.65 i MECHANICAL: $ 152.36 � ; SUB-TOTAL $ 2,256.50 i TOTAL $ 2,256.50 SEW ER: na WATER: na IRRIGATION: $ - TOTAL: $ - WATER METER: na I IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: na INSPECTION TOTAL: PERMIT TOTAL - TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,809.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 j 100.0% .$ 4,828.00 , 1.0% $ 48.28 j TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 '' 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 12,087.69 � - _ � _ , �R,, � PASCO COUNTY, FLORIDA � . �. , Permit No, ���� � Date Permitted ,. ' , ,Builder Name/Owner Name _�.Q�'l�lGc,,r- �� Control# � , Courity Parcel No. (�Z(o-Z(—�070—D01�0o_ppg� SubDiv: �, '�a Address/Location tQ�(o 3 ��� ��� �'�— , Classification/Type of Use )2.Qs4,�n�r�o�,1% $ ` . �2. TRAN�SPORTATION IMPACT FEE Rate: (� , Sq Ft Unit: 3, J S"7 ' • ;Exem t ��y`f-- � P ❑ Yes � No How De t e r m i n e d Impact Fee Amount $ '�� 6�2, Zone No. 'i TAZ: , � SCHOOL IMPACT FEE �, ' Account (056) Single-Family Detached House Amount $ _ 4, �?(,,, � ' (057) Mobile Home _c________ I (058) Other Resfdential 123) Collection Fee ;Exempt [� Yes � iVo � How�Determined � � � • ; ' ;PARKS AND RECREATION FEE i Land Account Land Credit Land Total I • •Recreation Account Recreation Credit � Recreatfon Total _ Zone TOTAL AMOUNT $ J �0 9,�j� Exempt • � ❑ ❑ No How Determined • . �LIBRARY FEE Land Account Land Credit , I, Land Total Facility Account __ Facility Credit ' , Facility Total Exempt Yes � , ; ❑ ❑ No How Determined �_ Total Amount � RESOURCE FEE - � • TOTALAMOUNT ERU .. � . . I Prepared .. . ; Checked By � NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE RECEIPTED FOR BY A CENTRAL E MI11'T NG OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but slmply receipt of a copy of this form,placing the buflding perm(t owner on notice of this assessment and the,conditions of payment for same. 1 I DATE RECEIVED BY I RECEIPT NO. �_ pATE �_ gY ', • . ; � ' I I, Crystal Reports Viewer Page 1 of 1 ' ; 1oos; 'CIY1fA�111.REP0tITii' � ,�1 Gq i�Peremelers '�'.,Oroup Trce E� f:' �'�/1 h il � '¢: ,C_�•(�,�(� __,f, i, �_�_.._... - Maln RepoA I _ �i -�`-� o ' - PASW COUNTY , `� 6UILDING CON57RUCTION SERVICES ::�,��' 873TCIItzens Drive. ' Dale:7l81/2017 ;:�h�ii�TS„r SUila 230 - �1HI�.. ' New Port Richey,FL 34654 - " ' 727-847-8127 i �. � �`�` �NOT A PERMIT ** ; Receipt#: 1696868 I ; - FEEDESCRIPTION ACCOUNTCODE NI7S INVO_ 1_CE� FEEAMOUN7 PAID RECEIPT# j�� ' Impec�Fea Residenllel Solid _845038a000 27.BB 127432e 527:88 527.88 1696886 7f31l17 ; Was�e Single Femlly" " I TOTALS: 5z7•88 S27.B8 � I Recei t' ,Pald Bv Check fl' CC utfi A er D Worketatlon Recelot Dale Amt Pald� � 1696866 Check B81B55 294 BCCCP3BW 07/3V2017 S27.88� ' I " I Total Payments: 'S?7.88 Pevor ddres"e Phone � ; LENNAR�HOMES 8551PA�EN WHEELST I ZHILLS'SW P.YMNT PERMI71t 18519 ' - � - Commenta• - -- d U52821007UD040000DeD I i �, ( 02895856 Lennar Homes,L�C JPMorgan Ghase 8ank N.A.. � STUB CHECK NO 881855 � �� : lNi�o10E 900000.1010.114 . � I of 1 DATE, 07/20/17 CO,H NUMBER DATE _ PAYhIENTdDN/CE ' GROSS D/SCOUNT NF.T I 15225 15225710409.401435' 071017' 15225710409 401433 � ' S27:88 �0.00 • S27_gg ;Ir � - o, " � - � I _ � v/�,�,� �l• , , -� ,� - �• l5� . ( ` �L �yL c.-� f � -( � ��� ; ;- , �� ,, L° ��,�� � , ; ' --� E'� f_ , � � �, , �r i � � 6820202- Ciry o Zephyrhills " � FBA�Trudy Bihm 49-8144 ,+ 5335'81h Slteet,_: $27:88 $0:00 $27.8$ � _�� 7.e'li'd�ills FL 33542 -. � " ' - � - - . ' - �� i � � - � http://crystal3.accela:com/myreports/adapter/XReportmp.aspx?re.... 7/31/2017 � - � { I I�III�IIIII��III II�II I��II I�III I�III IIIII II�II II�II�III I�II I . 201707712� ' P2cpt:1�65620 Rec: 10.00 ! D5: 0.00 IT: 0.00 - 05%23/2017 L. S. , Dpty Clerk ' PqULR S 0'NEIL,Ph D PRSCO CLERK & COMPTROLLER ; 050R3BK�la����m_P�_ i��� _ � Permit No. Parcel ID No 05-26-21-0070-00400-0090 , NOTICE OF COMMEfVCEMENT State of Florida County of PaSCO THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement: , 1. Description of Property� Legal SILVERADO RANCH SUBDIVISION PHASES 2 3 &4 PB 73 PG 59 BLOCK 04 LOT 09 st�eetaad�es5. 6563 Paden Wheel Street Zephryhills FL 33541 • 2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence � 3. Owner Information: Lennar Homes, LLC Name 4600 W Cypress St. Ste 200 Tampa FL. 33607 Address City State Interest in Property� Name of Fee Simple Titleholder N�A " (If other than owner) I Address City State � 4. � contractor� Lennar Homes, LLC Name 1 4600 W Cypress St, Ste 200 Tampa FL,.33607 ;4ddress City State Contractor's Telephone No. $13 574 5700 � 5. surety� � . :'. N/A Name Address City State � Amount of Bond: $ Telephone No.. , i � s �ender N/A ' Name � � � , Address City State � Lender's Telephone No 7. Persons within the State of Florida designated by the owner upon whom notiCes or other documents may be served as provided by Section 713 13(1)(a)(7),Florida Statutes: Lennar Homes. LLC ' Name , 4600 W Cvpress St, Ste 200 Tampa FI_133607 ' Address City State Telephone Number of Designated Person: $13 574 5700 8. In addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. i Telephone Number of Person or Entity Designated by Owner: ; I � 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: � WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT I ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN ! RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE � RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. ; STATE OF FLORIDA � ' COUNTY OF PINELLAS �� j Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager � t Vice President ' i 5ignatory's Title/Office i The foregoing instrument was acknowledged before me this 2� day of MafCh �v� � ,by Steve SI1'llth as Vice Pfesident (type of authorit :ce�,trustee;-attorney in fact)for Lennar Homes. LLC (name of pa on behalf of instrument was executed) Personally Known�OR Produced Identification❑ Not �nature , Type of Identification Produced - � �� �ISSa olleran Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury,I declare that I have read the foregoing and that the=facts stated in it are tr,ue to the best of my knowledge and belief. ' I `� �--�� . • '����"�'' ELISSb�,HOLIERAN Signature of Natural Person Signing Above ! � _��'�,.�,.Cemmlealon#FF 885A37 { ` +s�`.=Explr�s June 8,2020 I wpdata/bcs/bcsform: /�OI;�.,`' 9unJedThN7royFulnlnuunna�00aB5-7p1p � a3'���m U���LURIf�A, �C3t��9`s'�°�����CL� �������� THIS IS Tn CERTIFY THAT THE FOREGOING IS A `�,�� � �=-^� ��'._'��'o TR�JE AND C�RRECT COPY dF,THE DOCUMENT �' � �,,,��� �b �' .�" ,t� �`o� � Ot� FIIE QR.�F4P�B��C-RECOI�D If�1 THIS OFFICE � *;,: : �i� 1�v'1T ESS MY HAND AN FFICIAL 5EALTHIS � : .,� � ;`Z�DAY OF 2 R" �'.:. "�yoa�•c rrL��;' '� f�14?, PTF20LLE , � i�ryLLA S O NEII. ` ° ` � DEPUTY CLERK � . o � �Y ���, �=�#�,�_..�:� .�}���. =.� '` Q., �-y .y , 8�ny �'. I i i c_ y' I , I FORM R405-2014 � FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method � Project Name: 3127 sf ADS Builder Name: LENNAR HOMES i street: 6563 Paden Wheel Street Permit Office: Cl of Zephyrhills City,State,Zip: ,FL, Permit Number� ��.��� , Owner LENNAR HOMES .lurisdiction: 611600 Design Location: FL,Tampa � 1 New construction or existing New(From Plans) 9. Wall Types(2907.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ftZ � b Concrete Block-Int Insul,Exterior R=4 1 1309.80 ft 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ftZ � 4 Number of Bedrooms 5 d.N/A R- ft= 10.Ceiling Types (1946.0 sqft.) Insulation Area � 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1772.00 ftZ � 6. Conditioned floor area above grade(ftZ) 3127 b.Knee Wall(Vented) R=30.0 174.00 ftZ Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ftZ 7. Windows(366.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 585 ! a. U-Factor• Dbl,U=0.54 162.68 ftz b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 545 � SHGC• SHGC=0.31 ' b. U-Factor Dbl,U=0.56 117.00 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.20 � b.Central Unit 25.2 SEER:16.20 c. U-Factor Dbl,U=0.56 86.67 ft2 � ' SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor• N/A ftz a.Electric Heat Pump 21.8 HSPF:9.00 � SHGC• b.Electric Heat Pump 21.8 HSPF:9.00 Area Weighted Average Overhang Depth: 4.213 ft. ' Area Weighted Average SHGC� 0.303 14 Hot water systems i a.Electric Cap�40 gallons 8. Floor Types (1772.0 sqft.) Insulation Area EF 0.950 � a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ft� b. Conservation features ' b.Floor over Garage R=11.0 260.00 ftZ None I c.N/A R- ftZ 15.Credits Pstat I Total Proposed Modified Loads: 91.14 pASS � Glass/Floor Area: 0.117 � Total Baseline Loads: 90.86 I hereby certify that the plans and specifications covered by Review of the plans and �����.'�`:q�� ' '''- ,. this calculation are in compliance with the Florida Energy specifications covered by this ti, ,,.� ; 4•,, 0,�, Code. calculation indicates compliance ��f„�'' , `':s'�.��ti, ,�`�. �ave �1.��-r`c!� With the Florida Energy Code.' �+ rnut�.��'`%r,.,:_�`:;••:�"�,� � �:,,r.tsu.. PREPARED BY: '� Before construction is completed � --�- � ' t7 D A T E: this building will be inspected for � �}�'` � : compliance with Section 553.908 * �' "' ' °o Florida Statutes. l �S I hereby certify that this building,as designed, is in compliance � � ��. with the Florida Energy Code. � ��b�� OWNER/AGENT. BUILDING OFFICIAL. DATE: DATE: - - Compliance requires certification by the air handler unit manufacturer that the air handle enclosure qualifies as i certified factory-sealed in accordance with R403.2.2.1. I -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage , � i test report in accordance with R402.4.1.2. I - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, I tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. � 1/3/2017 12:24 PM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 � II i � , FORM R405-2014 i FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION � Florida Department of Business and Professional Regulation - Residential Performance Method i Project Name: 3127 sf ADS Builder Name: LENNAR HOMES i street: 6563 Paden Wheel Street Permit Office: City of Zephyrhills City,State,Zip: ,FL, Permit Number Owner• LENNAR HOMES Jurisdiction: 611600 Design Location: FL,Tampa i 1 New construction or existing New(From Plans) 9 Wall Types(2907.1 sqft.) Insulation Area � 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ftz � b.Concrete Block-Int Insul,Exterior R=4.1 1309.80 ftZ � 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ftZ 4 Number of Bedrooms 5 d.N/A R= ftZ 5. Is this a worst case? Yes 10.Ceiling Types (1946.0 sqft.) Insulation Area Z I , a.Under Attic(Vented) R=30.0 1772.00 ft 6. Conditioned floor area above grade(ftz) 3127 b.Knee Wall(Vented) R=30.0 174.00 ft� � Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ I 11.Ducts R ftz 7 Windows(366.3 sqft.) Description Area a.Sup:Attic,Ret: 1st Floor,AH:1st Floor 6 585 a. U-Factor• Dbl,U=0.54 162.68 ft2 b.Sup• Attic,Ret:2nd Floor,AH:2nd Floor 6 545 ' SHGC• SHGC=0.31 � b. U-Factor Dbl,U=0.56 117.00 ft2 12.Cooling systems kBtu/hr Efficiency ' SHGC� SHGC=0.28 a.Central Unit 25.2 SEER:16.20 b.Central Unit 25.2 SEER:16.20 c. U-Factor: Dbl,U=0.56 86.67 ftz ' SHGC SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor• N/A ftz a.Electric Heat Pump 21.8 HSPF:9.00 SHGC� b.Electric Heat Pump 21.8 HSPF:9.00 Area Weighted Average Overhang Depth: 4.213 ft. Area Weighted Average SHGC� 0.303 14 Hot water systems i a.Electric Cap:40 gallons B. FloorTypes (1772.0 sqft.) Insulation Area EF•0.950 a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ftz b. Conservation features b.Floor over Garage R=11.0 260.00 ftZ None c.N/A R= ftZ �5.Credits Pstat Glass/FloorArea: 0.117 Total Proposed Modified Loads� 91.14 pASS Total Baseline Loads: 90.86 ; I hereby certify that the plans and specifications covered by Review of the plans and ��'C�':�T.q?.� this calculation are in compliance with the Florida Energy specifications covered by this ti ,� ,� `"�:�; Q�,; Code. calculation indicates compliance �'�:r,,,,�'' , ,.:``;�-t +�+ wi t h t he F lori da Energy Co de. E+ ur�rr�,� "a'"�'�'�``,ti��7 I PREPARED BY: �QVe ���G� Before construction is completed � .-b.�•, �� `���., ":`,'���'" � D A T E. t hi s bui l di n g w i l l b e i n s p e c t e d f o r t�g. ��i�;� � . compliance with Section 553.908 * '° , . .� Florida Statutes. � �: I hereby certify that this building,as designed, is in compliance � �� with the Florida Energy Code. ��1�y�",�' � OWNER/AGENT: BUILDING O FIC L. DATE. DATE. � � - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as ' certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. I - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, ; � tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. j I � 1/3/2017 12:24 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 I Y � FORM R405-2014 � ' FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method j , I Project Name: 3127 sf ADS � Builder Name. LENNAR HOMES ' street: 6563 Paden Wheel Street Permit office: C1ty of Zephyrhills �i City,State,Zip: ,FL, Permit Number Owner LENNAR HOMES ,lurisdiction: 611600 I Design Location: FL,Tampa � � 1. New construction or existing New(From Plans) 9. Wall Types(2907.1 sqft.) Insulation Area { 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ftz i b.Concrete Block-Int Insul,Exterior R=4.1 1309.80 ftz �, 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ftZ 4. Number of Bedrooms 5 d.N/A R= ftz 5. Is this a worst case? Yes 10.Ceiling Types (1946.0 sqft.) Insulation Area Z a.Under Attic(Vented) R=30.0 1772.00 ft 6. Conditioned floor area above grade(ftz) 3127 b.Knee Wall(Vented) R=30.0 174.00 ftZ � Conditioned floor area below grade(ftz) 0 c.N/A R= ftZ I 11.Ducts R ftZ 7 Windows(366.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH: 1st Floor 6 585 a. U-Factor Dbl,U=0.54 162.68 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 545 � � SHGC• SHGC=0.31 � b. U-Factor Dbl,U=0.56 117.00 ftz 12.Cooling systems kBtu/hr E�ciency a.Central Unit 25.2 SEER:16.20 SHGC: SHGC=0.28 b.Central Unit 25.2 SEER:16.20 , I c. U-Factor Dbl,U=0.56 86.67 ftZ SHGC� SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor• IV/A ftZ a.Electric Heat Pump 21.8 HSPF:9.00 SHGC: b.Electric Heat Pump 21.8 HSPF:9.00 I Area Weighted Average Overhang Depth: 4.213 ft. { Area Weighted Average SHGC� 0.303 14 Hot water systems a.Electric Cap:40 gallons B. Floor Types (1772.0 sqft.) Insulation Area EF.0.950 a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ft2 b. Conservation features b.Floor over Garage R=11.0 260.00 ftZ None c.N/A R= ftZ 15.Credits Pstat I Total Proposed Modified Loads: 91.14 pASS Glass/Floor Area: 0.117 I Total Baseline Loads. 90.86 I hereby certify that the plans and specifications covered by Review of the plans and 0�'�E�T1q1.�- . this calculation are in compliance with the Florida Energy specifications covered by this �, ,, ~ (,��, ' Code. calculation indicates compliance ��n,,''' l``='.,�`. +� � �aVe �/��G� with the Florida Energy Code. F^+ rar+rr�''% ''•���°�"��sti O , PREPARED BY: P �� '�.l �"���� W� Before construction is com leted c� � � � C,;w C7 � DATE: this building will be inspected for � ).,,�;- �,. . � compliance with Section 553.908 * �-° ,. : -�, I hereby certify that this building,as designed, is in compliance Florida Statutes. �",�, ,_ ���.. i with the Florida Energy Code. , ��D y�E'� j OWNER/AGENT. BUILDING OFFICI L. I DATE: DATE: � - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. � - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. I 1/3/2017 12:24 PM EnergyGauge�USA=FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 I II r y I FORM R405-2014 I PROJECT ' I Title: 3127 sf ADS Bedrooms: 5 Address Type: Street Address � Building Type: User Conditioned Area: 3127 Lot# I Owner LENNAR HOMES Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: LENNAR HOMES Rotate Angle: 45 Street: Permit Office: Cross Ventilation: No County� Pasco Jurisdiction: Whole House Fan: No City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE � ` / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range � I FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS , Number Name Area Volume , I 1 Blockl 1512 14061.6 � �2 Block2 1615 12920 i SPACES � Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 1st Floor 1512 14061.6 Yes 1 1 1 Yes Yes Yes 2 2nd Floor 1615 12920 No 5 4 1 Yes Yes Yes I FLOORS I # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet II 1 Slab-On-Grade Edge Insulatio 1st Floor 173 ft 0 1512 ft2 ___ 0.3 0 0.7 2 Floor over Garage 2nd Floor ____ __� 260 ft2 11 0 0 1 ROOF � Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip r Composition shingles 1982 ftZ 0 ftZ Medium 0.85 N 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1772 ft� N N i 1/3/2017 12:24 PM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 2 of 5 � � , 'i FORM R405-20•14 i " CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type �i, 1 Under Attic(Vented) 2nd Floor 30 1772 ftz 0.1 Wood I'i 2 Knee Wall(Vented) 2nd Floor 30 174 ft2 0.11 Wood � � WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below � - - I _ 1 N=>NE Exterior Concrete Block-Int Insul 1 st Floor 4 1 7 6 9 4 70.0 ftZ 0 � 0 0.6 0 _2 N=>NE Exterior Concrete Block-Int Insul 1 st Floor 4 1 12 6 9 4 116.7 ftz 0 0 0.6 0 � _ 3 E=>SE Exterior Concrete Block-Int Insul 1 st Floor 4 1 45 4 9 4 423.1 ft2 0 0 0.6 0 _4 S=>SW Exterior Concrete Block-Int Insul 1 st Floor 4.1 14 4 9 4 133.8 ftz 0 0 0.6 0 j 5 W=>NW Exterior Concrete Block-Int Insul 1 st Floor 4 1 4 0 9 4 37.3 ftz 0 0.6 0 6 S=>SW Exterior Concrete Block-Int Insul 1 st Floor 4 1 25 8 9 4 239.6 ft2 0 0.6 0 ' 7 W=>NW Exterior Concrete Block-Int Insul 1 st Floor 4 1 31 0 9 4 289.3 ftz 0 0.6 0 - i _8 N=>NE Garage Frame-Wood 1 st Floor 11 19 4 B 0 154.7 ftz 0.23 0.01 0 � I _9 W=>NW Garage Frame-Wood 1 st Floor 11 6 B 8 0 53.3 ft2 0.23 0.01 0 10 NW=>N Exterior Frame-Wood 2nd Floor 11 7 6 B 0 60.0 ft2 0.23 0.6 0 11 N=>NE Exterior Frame-Wood 2nd Floor 11 29 4 8 0 234.7 ftZ 0.23 0.6 0 _12 NE=>E Exterior Frame-Wood 2nd Floor 11 7 6 B 60.0 ftz 0.23 0.6 � 0 , 13 E=>SE Exterior Frame-Wood 2nd Floor 11 44 B 8 357.3 ft2 0.23 0.6 0 � - � 14 S=>SW Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0.23 0.6 0 I 15 W=>NW Exterior Frame-Wood 2nd Floor 11 44 8 8 0 357.3 ft2 0.23 0.6 0 I i DOORS j # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated 1st Floor None .2 3 6 8 20 ftz 2 N=>NE Wood 1st Floor None .4 2 S 6 8 17.8 ftZ �, � WINDOWS I Orientation shown is the entered orientation(_>)changed to Worst Case. � Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 7.0 ftZ 6 ft 0 in 1 ft 0 in None Exterior 5 i 2 N=>NE 2 Metal Low-E Double Yes 0.56 0.28 32.0 ftZ 1 ft 0 in 11 ft 9 in None Exterior 5 � 3 E=>SE 3 Metal Low-E Double Yes 0.54 0.31 23.0 ftZ 1 ft 0 in 11 ft 9 in Drapes/blinds ExterioP 5 4 S=>SW 4 Metal Low-E Double Yes 0.54 0.31 23.0 ft2 1 ft 0 in 1 ft 6 in None Exterior 5 5 W=>NW 5 Metal Low-E Double Yes 0.56 0.32 33.3 ft2 25 ft 8 in 1 ft 0 in None None 6 S=>SW 6 Metal Low-E Double Yes 0.56 0.32 53.3 ftx 7 ft 0 in 1 ft 0 in None Exterior 5 7 W=>NW 7 Metal Low-E Double Yes 0.54 0.31 32.0 ft2 1 ft 0 in 11 ft 0 in None None 8 NW=>N 10 Metal Low-E Double Yes 0.56 0.28 16.0 ftz 1 ft 0 in 0 ft 8 in None Exterior 5 , 9 N=>NE 11 Metal Low-E Double Yes 0.56 0.28 46.0 ftz 1 ft 0 in 1 ft 0 in Drapes/blinds None 10 NE=>E 12 Metal Low-E Double Yes 6.56 0.28 16.0 ft' 1 ft 0 in 0 ft 8 in Drapes/blinds None 11 E=>SE 13 Metal Low-E Double Yes 0.54 0.31 6.7 ftx 1 ft 0 in 0 ft 8 in Drapes/blinds None , 12 S=>SW 14 Metal Low-E Double Yes 0.54 0.31 69.0 ft� 1 ft 0 in 0 ft 8 in Drapeslblinds None 13 W=>NW 15 Metal Low-E Double Yes 0.54 0.31 9.0 ftZ 1 ft 0 in 0 ft 8 in Drapes/blinds None � i I , I 1/3/2017 12:24 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Sofiware Page 3 of 5 � i � , � i FORM R405-20•14 ' GARAGE I # FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation i 1 611 ftz 260 ft2 72 ft 9.3 ft 1 I INFILTRATION i # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 I 1 Wholehouse Proposed ACH(50) .000274 2248.5 123.44 232.14 .2531 5 � � ' ' HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts ', 1 Electric Heat Pump None HSPF.8.9999 21.8 kBtu/hr 1 sys#1 � 2 Electric Heat Pump None HSPF:9 21.8 kBtu/hr 2 sys#2 ' � COOLING SYSTEM i I # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts , 1 Central Unit Split SEER:16.2 25.2 kBtu/hr 756 cfm 0.85 1 sys#1 � 2 Central Unit Split SEER.16.225.2 kBtu/hr 756 cfm 0.85 2 sys#2 i, HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation I 1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None i SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Modei# Area Volume FEF �i None None �Z � DUCTS � —Supply— --Return— Air CFM 25 CFM25 HVAC# i # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool I 1 Attic 6 585 ft2 1st Floor 155 ftZ Prop.Leak Free 1st Floor --cfm 45.4 cfm 0.03 0.60 1 1 2 Attic 6 545 ftZ 2nd Floor 185 ftZ Prop.Leak Free 2nd Floor —cfm 48.5 cfm 0.03 0.60 2 2 � 1/3/2017 12:24 PM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 4 of 5 � i ` , I FORM R405-20•14 I TEMPERATURES I Programable Thermostat:Y Ceiling Fans: I ' � Coolin Jan Feb Mar A r Ma X Jun X Jul Au X Se ]Oct Nov Dec Heatin9 f X�Jan f X�Feb f X�Mar E �APr f �May 4 �Jun � �Jul ��Aug 4 �SeP E ]Oct f X�Nov f X�Dec ' Ventin [ Jan [ Feb [X Mar [X A r [ Ma [ Jun Jul Au [ Se [X]Oct [X Nov [ Dec I Thermostat Schedule: HERS 2006 Reference Hours � Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 �', PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 � PM 78 78 78 78 78 78 78 78 78 78 78 76 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 � PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) . AM 66 66 66 66 66 68 68 68 68 68 68 68 � PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION � � Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 1 -Electric Heat Pump 0% 1 -Central Unit I None 0 0 0 2-Electric Heat Pum 0% 2-Central Unit , I � � I 1/3/2017 12:24 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 I t� � , � FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) ' �I DISPLAY CARD � , , ESTIMATED ENERGY PERFORMANCE INDEX* = 100 � The lower the EnergyPerformance Index, the more efficient the home. � , , FL, I 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area , 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ft2 i - b.Concrete Block-Int Insul,Exterior R=4 1 1309.80 ftZ 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ftZ i 4 Number of Bedrooms 5 d.N/A R= ftz 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area 2 a.Under Attic(Vented) R=30.0 1772.00 ft � 6. Conditioned floor area(ftZ) 3127 b Knee Wall(Vented) R=30.0 174.00 ftz 7. Windows'* Description Area c.N/A R= ftz � a. U-Factor• Dbl,U=0.54 162.68 ft2 11 Ducts R ftZ a.Sup.Attic,Ret:1st Fioor,AH:1st Floor 6 585 i SHGC• SHGC=0.31 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 545 ' b. U-Factor Dbl,U=0.56 117.00 ft2 SHGC• SHGC=0.28 12.Cooling systems kBtu/hr Efficiency ! c. U-Factor Dbl,U=0.56 86.67 ftZ a.Central Unit 25.2 SEER:16.20 SHGC� SHGC=0.32 b.Central Unit 25.2 SEER:16.20 , d. U-Factor N/A ftZ 13.Heating systems kBtu/hr Efficiency ' SHGC: a.Electric Heat Pump 21.8 HSPF:9.00 Area Weighted Average Overhang Depth. 4.213 ft. b.Electric Heat Pump 21.8 HSPF:9.00 I Area Weighted Average SHGC� 0.303 B. Floor Types Insulation Area 14 Hot water systems Cap�40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ftz a.Electric EF 0.95 b.Floor over Garage R=11.0 260.00 ftZ I c.N/A R= ft� b. Conservation features ; None i 15.Credits Pstat I certi that this home has com lied with the Florida Ener Efficienc Code for Buildin I Cons uction through the above energy saving features wh ch will be nstalled (or exceeded) ,�o'���E��Arro in this home before final inspection. Otherwise, a new EPL Display Card will be completed �w`�' ``,�' '`: ''t' yj �r.rJ�.. =;=`.��°ati�� based on installed Code ompliant features. �`'� +�r�r,�..��� :;`z;�'"�';�",",,� o � ... �y���� �� �. � � Builder Signature: Date• 03/22/17 `� ����'-- � � ° �. Address of New Hom : 6563 Paden Wheel Street City/FL Zip. Ze�hXrhills,FL 33541 �c: .: �5`�° - o�tiv�'�`. *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient , mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. I **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. ' � I 1/3/2017 12:26 PM EnergyGaugeO USA-FlaRes2014 -Section R405.4 1 Compiiant Software Page 1 of 1 ` , � � Buildin Anal sis Job: 3127sf � Y Date: 3/22/2017 lower floor By: Dave Aldrich I Bayonet Plumbing Heating and Cooling � 8950 New York ave,Hudson � � • • ' For� Lennar Homes P - • � e e Location: Indoor: Heating Cooling ! Tampa InternationalAP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight � Wind speed (mph) 15.0 7.5 Fireplaces 0 � _ • Component Btuh/ft2 Btuh % of load ! Walls 5.5 6963 28.8 � Glazing 30.2 6158 25.5 Doors 23.5 466 1.9 'i Ceilings 1.3 281 1.2 ' Floors 3.8 5699 23.6 Infiltration 19 2752 11.4 ' Ducts 1852 7.7 �. Piping 0 0 Humidification 0 0 Ventilation 0 0 �"'��A { Adjustments 0 � � li Total 24170 100.0 e • e Component Btuh/ftZ Btuh % of load Walls 2.8 3512 18.2 "" • Glazing. 44.3 9039 46.9 Doors 18.4 365 1.9 Ceilings 1.8 386 2.0 Floors 0 0 0 � Infiltration 0.4 595 3.1 Ducts 2136 11 1 Ventilation 0 0 _ ���� Internal gains 3250 16.9 m� Blower 0 0 ' °""' i Adjustments 0 '" � ' Total 19283 100.0 °"'"° Latent Cooling Load=2611 Btuh Overall U-value= 0.155 Btuh/ftZ-�F I Data entries checked. I� , �; t WI'1 f1tS0'�` 2017-Marv2213:45:29 ', �� 9 Right-Suite�Universa12013 13.0.09 RSU05714 page 1 H:ILENNAR LOADS\3127 sf ADS 2-2tons.rup Calc=MJB Front Door feces: E � �f � r , I Buildin Anal sis Job: 3127sf ; � Y Date: 3/2212017 upperfloor By: DaveAldrich Bayonet Plumbing Heating and Cooling � 6950 New York ave,Hudson � • ' • . For� Lennar Homes � � - • o • • � Location: Indoor: Heating Cooling I Tampa International AP, FL, US ' Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: � Daily range(°F) - 14 ( L ) Method Simplified � Wet bulb(°F) - 77 Construction quality Semi-tight � Wind speed (mph) 15.0 7.5 Fireplaces 0 ' � Component Btuh/ftz Btuh % of load � Walls 3.8 4450 28.2 ' Glazing 30.2 4895 31.1 Doors 0 0 0 Ceilings 1.3 2026 12.9 Floors 0 0 0 Infiltration 1.9 2471 15.7 j Ducts 1914 12.1 Piping 0 0 �..,. Humidification 0 0 Ventilation 0 0 s., � Adjustments 0 Total 15756 100.0 e • • Component Btuh/ftz Btuh % of load Walls 2.7 3213 16.3 `" ~w' Glazing 51.9 8414 42.7 , - Doors 0 0 0 Ceilings 1.7 2801 14.2 ' , ' Floors 0 0 0 Infiltration 0.4 534 2.7 � - ,ti.m. I D ucts 2212 11.2 - Ventilation 0 0 Internal gains 2550 12.9 Blower 0 0 ` "° , Adjustments 0 `°"° �-°- Total 19724 100.0 'i Latent Cooling Load=2501 Btuh , Overall U-value= 0.098 Btuh/ftz-°F ; Data entries checked. ' � i , i ' .� WI'1 htsoft` 2017-Marv2213:45:29 , �, � 9 Right-Suite�Universal 2013 13.0.09 RSU05714 page 2 � H:\LENNAR LOADS\3127 sf ADS 2-21ons.rup Calc=MJB Front Door feces: E e' � I Job: 3127 sf Project Summary Date: 3/22/2017 i lo wer floor By: Dave Aldrich Bayonet Plumbing Heating and Cooling � �, 8950 New York ave,Hudson '' � Q • � For: Lennar Homes �� Notes: ADS specs � � - • � a I Weather: Tampa InternationalAP, FL, US � Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 39 °F Design TD 16 °F Daily range L Relative humidity 50 % , Moisture difference 55 gr/Ib � Heating Summary Sensible Cooling Equipment Load Sizing i Structure 22318 Btuh Structure 17147 Btuh , Ducts 1852 Btuh Ducts 2136 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh � Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24170 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 19283 Btuh I Method Simplified Latent Cooling Equipment Load Sizing � Construction quality Semi-tight Fireplaces 0 Structure 2234 Btuh Ducts 377 Btuh � Heating Cooling Central vent (0 cfm) 0 Btuh I Area(ftz) 1512 1512 Equipment latent load 2611 Btuh Volume(ft') 16162 16162 � Air changes/hour 0.24 0.12 Equipment total load 21894 Btuh Equiv.AVF(cfm) 64 33 Req. total capacity at 0.85 SHR 1.9 ton i Heating Equipment Summary Cooling Equipment Summary I Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-024-230-18 Cond 14HPX-024230-18 AHRI ref 5186808 Coil CBX27UH-024-230*++TDR AHRI ref 5186808 Efficiency 9 HSPF Efficiency 13.7 EER, 16.2 SEER Heating input Sensible cooling 21420 Btuh Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh Temperature rise _ 25 °F Total cooling 25200 Btuh i Actual air flow 800 cfm Actual air flow 800 cfm �, Air flow factor 0.033 cfm/Btuh Air flow factor 0.041 cfm/Btuh � Static pressure 0 in H20 Static pressure 0 in H20 � Space thermostat Load sensible heat ratio 0.88 i i Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .L �,}.. WCI htsoft° 2017-Mar-2213:45:30 � 'I" 9 Rlght-Suite�Unlversal 2013 13.0.09 RSU05714 Page 1 � H:ILENNAR LOADS\3127 sf ADS 2-2fons.rup Calc=MJ8 Front Door faces: E I i II �� , Job: 3127 sf � Project Summary Date: 3/22/2017 upperfloor By: DaveAldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson I � � � � e ' For Lennar Homes I I Notes: ADS specs i � � i I � � - � � • � Weather Tampa InternationalAP, FL, US Winter Design Conditions Summer Design Conditions I Outside db 31 °F Outside db 91 °F I Inside db 70 °F Inside db 75 °F Design TD 39 °F Design TD 16 °F Daily range L Relative humidity 50 % ' ' Moisture difference 55 gr/Ib i I Heating Summary Sensible Cooling Equipment Load Sizing � Structure 13842 Btuh Structure 17512 Btuh i Ducts 1914 Btuh Ducts 2212 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh ' Piping 0 Btuh I Equipment load 15756 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 , Infllt�atiOn Equipment sensible load 19724 Btuh Method simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2108 Btuh Ducts 392 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 1615 1615 Equipment latent load 2501 Btuh Volume(ft') 12920 12920 Air changes/hour 0.27 0.14 Equipment total load 22224 Btuh Equiv.AVF (cfm) 57 30 Req. total capacity at 0.85 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-024-230-18 Cond 14HPX-024-230-18 AHRI ref 5186808 Coil CBX27UH-024230"`++TDR AHRI ref 5186808 Efficiency 9 HSPF Efficiency 13.7 EER, 16.2 SEER � Heating input Sensible cooling 21420 Btuh Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh Temperature rise 25 °F Total cooling 25200 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.051 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.89 i i Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .� WI'1 htsoft" 2017-Mar-2213:45:30 �`' � 9 Rlght-Sufte�Universal 2013 13.0.09 RSU05714 pa9e 2 , �"'�` H:\LENNAR LOADS\3127 sf ADS 2-2tons.rup Calc=MJ8 Front Door faces: E � � . � Manual S Compliance Report Job: 3127sf Date: 3/22/2017 lower floor By: Dave Aldrich Bayonet Plumbing Heating and Cooling 6950 New York eve,Hudson I i � • ' � S For� Lennar Homes li . • e • � Design Conditions Outdoor design DB: 91.3°F Sensible gain: 19283 Btuh Entering coil DB. 75.6°F � Outdoor design WB. 77.3°F Latent gain: 2611 Btuh Entering coil WB. 62.8°F � Indoor design DB: 75.0°F Total gain: 21894 Btuh � Indoor RH. 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP ' Manufacturer: Lennox Model: 14HPX-024-230-18+CBX27UH-024-230*++TDR � Actual airffow: 800 cfm '' Sensible capacity� 21420 Btuh 111% of load I Latent capacity: 3780 Btuh 145% of load � Total capacity� 25200 Btuh 115% of load SHR: 85% � I e e • Design Conditions � i Outdoor design DB. 30.8°F , Heat loss 24170 Btuh Entering coil DB 69.6°F ' Indoor design DB• 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer� Lennox Model: 14HPX-024-230-18+CBX27UH-024-230"++TDR Actual airflow: 800 cfm � Output capacity� 21800 Btuh 90% of load Capacity balance: 40 °F Supplemental heat required: 2370 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 7.1 kW 100% of load Temp. rise: 50 °F I The above equipment was selected in accordance with ACCA Manual S. ' � i � � . � ,�, wri htsoft� 2017-Mar-2213:45:30 �, ' 9 Right-Suite�Universal 2013 13.0.09 RSU05714 Page 1 �'� H:\LENNAR LOADS\3127 sf ADS 2-2fons.rup Calc=MJB Front Door faces: E � ,� . . : .i Manual S Compliance Report Job: 3127sf � Date: 3/22/2017 upperfloor By: DaveAldrich � Bayonet Plumbing Heating and Cooling ' B950 New York ave,Hudson , � 0 ' • ! For: Lennar Homes '�I i e � • e • I, Design Conditions Outdoor design DB 91.3°F Sensible gain: 19724 Btuh Entering coil DB 75.7°F i Outdoor design WB. 77.3°F Latent gain: 2501 Btuh Entering coil WB� 62.8°F i Indoor design DB: 75.0°F Total gain: 22224 Btuh i Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data atActual Design Conditions � Equipment type: SpIitASHP � Manufacturer� Lennox Model: 14HPX-024-230-18+CBX27UH-024-230`++TDR i Actual airflow: 800 cfm �I Sensible capacity: 21420 Btuh 109% of load � Latent capacity: 3780 Btuh 151% of load Total capacity� 25200 Btuh 113% of load SHR. 85% • e • Design Conditions Outdoor design DB. 30.8°F Heat loss: 15756 Btuh Entering coil DB� 69 6°F i Indoor design DB: 70.0°F � i� , Manufacturer's Performance Data at Actual Design Conditions ' Equipment type: SpIitASHP i Manufacturer: Lennox Model: 14HPX-024-230-18+CBX27UH-024-230*++TDR Actual airflow: 800 cfm Output capacity: 21800 Btuh 138% of load Capacity balance: 30 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer� Model: Actual airflow: 800 cfm Output capacity: 4.7 kW 102% of load Temp. rise: 50 °F , The above equipment was selected in accordance with ACCA Manual S. .� Wr� htS�1�.'� 2017-Mar-2213:45:30 � �� �` 9 Right-Suite�Universal 2013 13.0.09 RSU05714 paye 2 �'� H:\LENNAR LOADS\3127 sf ADS 2-2lons.rup Catc=MJ8 Front Door faces: E I i OS-26-21-0070-00400-0090 � Pasco County Property Appraiser Page 1 of 1 � i Data Current as Of: Weekly Archive - Wednesday, May 24, 2017 ' Parcel ID 05-26-21-0070-00400-0090 (Card: 001 of 001) � Classification 00 - Vacant Residential Mailing Address Property Value i LENNAR HOMES LLC Ag Land $0 i 4600 W CYPRESS ST STE 200 Land $28,470 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 6563 PADEN WHEEL ST ZEPHYRHILLS, FL 33541 ' 7ust Value $28,470 Legal DesCription (First 4 Lines) Assessed (Non-School Amendment 1) $28,470 SILVERADO RANCH SUBDIVISION PHASES 2, 3 &4 PB 73 PG 059 BLOCK 4 Taxable Value $28,470 LOT 9 � i 7urisdiction I City of Zephyrhills _ ! Land Detail (Card: 001 of 001) � —T------ —r------,-- Line � �Use Description�Zoning Units �Type_____ �Price Cond�tion iValue � 1 ���� 0100 SFR Vu� MPUD �� 6,000.00 jv SF_� $4.40 � 1.00 _� $26,400 ' 2 0100 SFR � � MPUD 6 272.00 SF $0.33 1.00 2 070 � � � { I , � I � $ , � Additional Land Information , ----- ---�---------_-�--__.__ __T______�e�_�_ , --�-- - I + � � FEMA �__.__.------------- Acres I 0.28 iTax Areai 30SI � Code -- � Residential Code I SLVRCPI f , Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved �� Extra Features (Card: 001 of 001)_ '� T----- Line ___,______�escription �Year ��nits �Value ��� ^ No Extra Features � � I Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC I _ ___.._�___.__�_---,._Y_..._._ _.__.---...f.__r_____.._.._______�____________ Month/Year _,Book/Page _ jType ;DOR Code jCondition �Amount � � � ' J 05/2017 1 9544/ 0893 ` �Warranty_Deed � 05 j Vacant I Multi-Parcel Sale I - r--=---- � 09/2011 8606 / 3376 � Warranty Deed ; 05 Vacant � Multi-Parcel Sale� ; 05/2010 � � 738 3 / 1912 � Certificate of Title j 12 � Vacant � $0 i � i i http://search.pascopa.com/parcel.aspx?parce1=2126050070004000090 5/25/2017 ' I I I Single Family Dwelling , Plan Review Comments � i ! 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. � 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. � 7. All property markers shall be uncovered and marked at time of first inspection. i 8. All A.D.A. requirements shall be met. 9. No electric, plumbing,mechanical, or framing shall be covered without an inspection and � approval first. � 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). I 11. Appliances shall not be installed in a location where subject to mechanical damage unless � protected by approved barriers. M303.4 of the F.B.0 ! 12. Water heaters shall comply with section P607.3 of the F.B.C. ; 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 � 14. Return air in all bedrooms. F.B.C. M1620.4 � 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. � 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. � � 17. All means of egress are to be in accordance with R311 of the F.B.C. � 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. � I 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. A112008 N.E.C. Codes will be enforced. 23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 22. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. ' F.F.E.-Finished Floor Elevation I F.B.C- Florida Building Code 5�'Edition , �', R.O.W.-Right of Way I A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008) . r �--•----_.___. , _._�..�-_—,._: �:: _ i-"��}'�s�,'r=�� i��-� ^ .,-� ,. =-s*a� "t; _ � � i..,��' �, . _ fi�;•.'�'` ��. - ��� . ..:.:. :.... ....¢,x.� ` _y, ., � .s,.,� � ��'' .�..�,..' a � .�F �,'�.... .#���[ �'vf� .i� . H � F �'�� � � �.`�A.' '3• - ^.. ; :... -- ' ',',.`�u t„�.d."�;ia�'�ti�..i`�'s�� ''Rt` ..3' - �,�'�*'"�'''-�r,�,w,,,�,i �'�r��" - �:.� � SCTS Hame ;tflg Fn' Us>r Reglstration Hnt Soptcs Su6m[C'Surct;arge �tass E.FaCs Nubtiotians; FliLS4fi"i fiC2S 5te M&� { lit�ics S�a(ch . i�'��w�C ��Iy�! �:M� produat Apprauai ' _ '��A: ( �USEA;pubiictlser �7 r .z�:,•_n�.;��;� ��;�� � �:r•.';ahr,�::.ai L,�a Appllcation Dctuil ..;".,��"`"�'�_�zx`���u�$S� `s ' �-",..�G�7�`'.,,T','.,�2. '�' ;'`- ,���'_`?�����',� Fl m FL216�5 � AppliCation Type �lew Code Verslon 261.4 Applicakion Status , Validated ' � Commeots. Archived �. Producc Manufacturer HomeGuard 6ullding Products,Inc. .4ddressfPhao�/Email 543.Q Sbawland Road ]acksonviC(e,Ft»3??54 , (9D4)Z46-1382 � jahn.cheslakQ11i9wra p,com - � Autharized Signature ]ohn Cheslak c;_ john.cheslak�a hgwrap.cum t 7echnical Representati've ` AddressfPhone/Email ' quaiity?�surancE RzpresentaHve �, Addr�ss(FhoneJEmai( � Categary �` RooFing Subcate�or; Undertaymznts � C4mplience Method Evafuation R��Urt from a ProducL Evaluatioa Entlty ` Evaluation Entity ]ntertek Testing Services NA,ln�. P , Qualtty Assurante EntiCy Interkek Testing Setvices NR,inc. Quaiity Assurahce Contract Expiration Date 01/Ol/2�16 ' validaked 6y Intertek Testing Services NA,rn[. i Gertlficate nf IndEpendence Reieren�ed 5tandard and Year{of Standard} Standard Year ASTM d226 . 2005 I{ r. � , Equivalence of Product Standards E- Cestified By Sectians from khe Code i � Product Approval Method Methad 1 Opkion C Dat2 Submltted O7/25/2017 I Date Va[idated D1/2�/2017 �i; I � , M_��:...:::., ---- '_ . ___�.__,________.�______.._ -- .�....______.� I C i� _. �J1�--...; Stcmma nf Products FL# MadeE,Number or Name Description 21fi7S.1 TougRSkin Synthetic Underfayments ToUghSkin 15,ToughSkin 20,ToughSkin 25,ToughSkin 3�,' ToughSkin 50 - Limits of Usa Fnstallatian Instructians _- /kppro�ed for use in HYHt:No R_�1o?5 Rt; :I romaGi; rd Tcu�hs4�•r 1^ssitillatr'� 9? Approved far use outside HVH2:Yes trstri�ctic-�.r=v?.odP ., ' Impact ResisEartt:N/A Verified 9y:lntertek T=sking Servfces N0.,inc. �esign Pressure:N/A Creatad by Inde.pendent Third Party: - OtF�er: Evaluakion Reparts Fi?1'u75 RG :E C�MR-1069 R�n�^.�o; i,- _ Sack Nexe �. • � ' i Contacr Us.:'<fi01 Blair Srone Road,Tallanrssee R32399 Phaner 950-.fHi-t324 Tt;e Stu2e oFF�o�ida is an ArVEEO employt^.Cor.vnnhf 2011'.-2�13 S[a[e nfFlnritlK. Priean SUfemen[::Accenit�ili[v SrekJnert::Refund Scatr_mem' I !� llnCer fio:da law�ernafl zddr�.�es aw_pu6iic recorzL If yvu de nac want your e•mail atlumss refe�seC In responsz to a public-remrGS requ�t,do not send ziectmnic � maA to[his en�ry.loscea�,�nta¢me otfice Cy phone o-6y trddi�onal mail.lf'}vu hate any questwns,olease contnR 85U.q87.7345.'�Pursuant co Sectinn�55.275 ,E (1�,Florida S�tu[es,effe2lve OeaW�l.,2012,licenszes IiceaseG under Chapter 95��F5.must O�viUe Uie CrPyartmen[wit;i en email a¢orrss iPthcy have one The emails.provided may be used:nr otiiclal commimlc::Uon wl:h Lhe.liceasee.However email addresocs are Oubfit c_tncd.lf you do flot wish w=upply a persanol address, "- plea,e vrvviJe the�e�am�ent w�Ui an emzii addmss which can trz made availaNx ta;hr pubiic To dziertnine�P ynu ar�a licensee un4er�LaU�r d55,F.�,oieese . cGck here, � Product Approval Accepts: - � --�.��-- ��" � ; �:�teelif,�ar�f - � - _ -_:��fe:: , _.... . ,,.::.. ......... ......... - , �. F S_ �• 4 . I �� ._ 1 t... . � � I , ` SKETCH ONLY SEC. 05. , TWP. 26 S, RNG. 21 E. PLOT P�AN ' NOT A BOUNDARY SURVEY LOT 9, BLOCK 4 BEARING BASIS: SILVERADO RANCH SUBDIVISION NORTH BOUNDARY OF SE% OF 05-26-21 BEING N 89'25'01" E PHASES 2� J� �C 4 ONL07AREACALCULATIONS THIS SURVEY IS SUBJECT TO ANY FACTS THAT PASCO COUNTY, FLORIDA. �o-r =_�22�z_68_sQ. FT. � MAY BE DISCLOSED BY A FULL AND ACCURATE LIVING AREA = 15�2 _SQ. FT. TITLE SEARCH. ALSO SUBJECT TO SETBACKS, ENTRY = 38 SQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD. GARAGE __ 611_ _SQ. FT. o PRELIMINARYDRAWING: CovERED �ANAI =_?s? __sQ. FT. M UNDERGROUND FOOTER, STEM WALL, AND THIS PLAN IS FOR PERMITTING PURPOSES PA110 =_ NJA __SQ. FT. II UNDERGROUND UTILITIES ARE NOT LOCATED OR ONLY, NOT FOR CONSTRUC110N. VERIFY _ SHOWN. ALL OIMENSIONS BEFORE ANY CONSTRUCTION. CONC. DRIVE __58?�SQ. FT. � A/C & CONC PAD =13__SQ. FT. DO NOT SCALE THIS PRINT DIMENSIONS AND PRIVATE SIDEWALK =_ 51�_SQ. FT. � NOTES TAKE PREFERENCE. ' LEGEND: IMPERVIOUS = 24 __% � �—►= PROPOSED DRAINAGE FLOW = 2988 _SQ. FT. � CERTAIN DATA SHOWN HEREON BASED ON (00.00)- = PROPOSED GRADE SOD =_9255__SQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT � E-00.00 = EXISTING GRADE OF'F'LOT AREA CALCULATIONS STRUCTURE TIES SHOWN HEREON DENOTES RIGHT OF WAY = 480.94 SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION , DRIVE APRON =�05__SQ. FT. TO PROPERTY LINE. PUBLIC SIDEWALK =199__SQ. FT. SOD = 77 ___SQ. FT. + ��0' UTILITY EASEMENT , • TOTALS '�" 10' DRAINAGE EASEMENT AREA = 12753.fi2S0. FT. PCP(P) ' I DRIVEWAY =�8�__S�. FT. RADIUS POINT� SIDEWALK = 250 _�Sq. FT. N 8835'27" W 60.00' SOD = 9362 SQ. FT. . • O LOT 10 BLOCK 4 � ���� �- PADEN WHEEL ��o� ���� ���s � =''- TRACT J °�} �- S $9`rJ7�'�3�� E s�J� 123.70' .�—� 99J "•'' C.*+n��.�r DRAINAGE AREA a ,o �, � �7 1 1Z 1 ** a o 6�'a5�6:, (R/W VARIES) (TRACT L) \ � — — — — — — — —�o — — — — — ^�- — — �?. :Z\. i Y`.��':'��o:. � �CO ^ '�+'r s-'7 ' � O� M v� ,.;�� .�:'. '•O 6' ' .' �,,? '• .a; .i9� CONSERVATION�-�� �� �Q �'o• '. LINE \ � p�:� ,,�1�� ''* \ Z 59.8 .�. ,lL.- '� \ �� • � � .'f�,. . \ o ..'" I �J 4y� O,o °'' g °� i � \ N Y f�ON �`6� .�: �/ ^i 'u;po. 4�t�N O . \ Q�o :•,�a� N.� �ya� � ��A' � � p,2. ��?�''� • LOT 9 \ BLOCK 4 S�407�32 W 1Se Z 2 °�1 � , • \ � N 35�3 ,�� � l A2 V / 1 •�W SO, �� �` WETLAND " LOT 8 , I LINE , � �O BLOCK 4 1 � , � TRACT J � � WETLAND � CONSERVATION `S7� ,�... ; AREA Q �j, 'o� � � 69�,6'��G � � � I \ �\ NOTES: � LOT GRADING TYPE = B \ CONSERVATION � PROPOSED PAD ELEVATION = 108.10' LINE FRONT SETBACK = 20' or 22' ' \ � SIDE SETBACK = 7.5' i REAR SETBACK = 15' CURVE DATA CURVE RADIUS ARC CHORD BEARING DELTA PROPOSED: aea so.00� 14.36' 14.33' S OS'26'54" E is•az•sa�• LOWEST FLOOR ELEVATIONS: C169 60.00' 41.48� 40.66' S 32'06�47" E 39'36�52" LIVING AREA: 108.80' DESCR[PTION: GARAGE AREA: 108.26' � LOT 9, BLOCK 4, MAP OR PIlaT ENTITLED "SILVERADO RANCH ELEVATIONS REFERENCED TO � SUBDIVISION PHASES 2, 3 & 4", AS RECORDED IN PIAT NORTH AMERICAN VERTICAL � BOOK 73, PAGES 59 THROUGH 65, OF THE PUBLIC RECORDS DATUM OF 1988. MEAN SEA � ' OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL N0. 120230 0455 D EFFECTIVE DATE: 09/30/1992 Project Number: _____ Square Feet: 12272.68 f LENNAR HOMES LEGEND: (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, r�= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= - CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, U P= UTILITY POLE, W F= WOOD FENCE, R = RADIAL JOHN R.BEACH&ASSOCIATES�INC. Drawn ey. ! � SMS � SURVEYORS AND MAPPERS Checked By. 911 WEST ST. PETERSBURG DRIVE JRB ONE OLDSMAR, FLORIDA 34677 Scale: WAY (813) 854-1276 FAX (813) 855-8370 1"=30' NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 3/20/2017 GH THE ORIGINAL RAISED SEAL OF A FLORIDA H . BEACH ATE LICENSED SURVEYOR AND MAPPER FLORID EG. LAND SURVEYOR No. 2984 B#4493 Revisions: � I [h � l°S' ,r -':y ' � ,,�v� � �, � ' � ' ' - '� � • - > �' `� � � � ! ,v ' i 6 •' � . 4 ' I 1 'L� ' 1 � ` �=�;09.70 �\ G. � 1 ,B-• c,r �'F=1 Q9_6D . � �'1�'' .S FF=1 Q9.90 � �_ �r� �' ' I LOT 12 - " t . ��` ro-`� L�OT 2 � L0� 1 �.� '•. 9� ..: `� I� , -�• ' I PAB=108.9 ,� �� r � �`r. 6 '� OO Uy-_� � �'� Q. rtr. PA�EDA Q �` _,..r�. ! � �� �.... �r _ U � �€� � � � •� FF=11,�T.�O - � O� �1 O . , ��\ . , � r� ;�� � e. 'te- 1` t\ '�' .�� `� � �� LOT 9 � � , �\ ,c � • � �' S ,,,� ,s- � � PAD-ti 09.6 � � 1 m t\ s- ��.�'� � n-� � �. � i , �,�Q'O' � �\ TYPE A . � � � � 1 . ' 7,� ��\ ,r . 7r i�' a- �,ia � � � ,�� � 110. �� � � \isy ��` � " � I FF=1�9.50 ;� )� , ,'� � � � r , 1 �,� V a, . ��• ,3 m• � _ ��- LO��t 1 !��.�- .�'� � 'r�,. � ti , ,w9 6' i6� �� , P 08_�tY '�V i ' 1� B' ti� \ C��� �� � f � �'x ` �� ..\ � �� ^ti �, P IT 6- _ �s- �'�, ,��E B � ,' o� `1 `° � LOT�� g. �- �; o �-� � , , a � ��4`�" p-� g' ��`� .� � O `� • �is•a'����" �c c-s �` ' �� PAQ=:11�.0 r-� - _�I �� FF=11Q_30 � �� � � � _ 6. '� . � �, TYPE A � � 1- ,�.� LOT 13 E:��e- � �6 _ i _ � : � < � . `� FF=110.80 FF=110_60 PAQ=103.6 �l a`L � -�"� � LOT 11 TYPE A �ar �z - o�r ���` _20 Y �' FF=108�;� � " O � PAD=110.1 PA�1Q9.9 � `m 1 '\ , �, _ � PAD�t� � � �� � `\� TYPE A 1`!PE A r � �� r ` i h� $``\\ �.,j6�-,' 1lFP��-_, i °� 6 b��,' Y�' � '�C �o � �a'�J • OC � '��` O1 'l� � `L , ^ o� � ^ti "P' � , ' � -�� -_�� .�O :7 p ` `b� 4�' �� a�`" (�a' i � � :� _-r�! � 1 � �� +• H 0.,,� � °�i, °"-��- � ---� . �6 , , [�� ,�_ '� . � ` ��i-� � ..;_'�" �''1 r' _ __-T6�33 ��O -;-1� �a �Q . +�{i"�Q���E'��.n '_�p_ �RAlM� E4SEMEN7 }�8 p�� � � Op s�� `7�' UT7- "F'ASc,IfENT �0 1y � ` �, 1 se• �� r . ,J� - -_ `�\\r (1_r L 6• .+.1 •nfG•n��.� � �' ; . � � � ��'` / 49. __ 4�(`y��' �� ^ ��oa.ao ` g � -r �� •� � _ �"' - ; �r. �. 'w0 e- f�'D=108.1 � $ /' � • '� '1 O 1 Ft . _ ��_��� ,V -��' � '�� �� 6 �PE B �� � � -- . ---'� ,` `�. ` , -i-� '� , � • ' � �� ,, ,- `'• m a�s �,-�^-- �' -� -"��'1 • � Y` `({��K�.l 2<•, � _`�� � �' � ,` • ,'•�J^� s(� Q _ _------ P - • ' . 1 -' �° UTll.ln' _��_L_� - ' �� • 1 Lv _ ' � �� 7�88 8 FFL0T9'90 ��rU"'°� � �= � c- FF'=1�9.a0 _. ,'[ �y u iz• , s �QT�_�� -' - PAD=109.2 , r C�7 • �� •--FF=110.�D � 1 1 a�' � �,<- _- PA�,�d8.3 FF=1�9.20 , FF=1t0.2Q 7YPE 8 � � x:'� -- t�• � TYPE��.. . . LC�T 7 ra LdT C� �=1�0.50 ti FF=110.50 FF=110_3Q.- � �OT 2 �.� � . � ' � 50 , ,,,<- PA�-108.5 �' • LOT 5 LOT 4 LOT_-3"- PAD=109.d , .- � ,. �g 6 C� � � -.PAD=ri.�B.S • PA�ff�.4�8 TYPE B c, ��' . °J� ���� � � � TYPE B ��8 RAD=t D9.8 PAD-=109.6 �j� ;1 , .s ,,. , �., T��'� 7YPE ��I• TYPE B �C� -T10 �t c ;�� �. ' � ��� � ,�j- � '� 107. ��rO �j��,,. �r � =�`'. � t � r r�is• O •- _:...-' - - ------ __ �,�.' a � y ��� �s -��� �:�,T T� -- oc - r � -� ��' - I. c- '� .. � � � , '\ ," • ,_ . . �. � � ``o ''�° ��\ ^�, .s' � � � - ��� '.' 1 - � �.,� . �' , '" -��� �'� p"' '�� C� 18'(87. ,s � ���:� � _�z_ �� , • ^ --��� c c _ - ��-' s� � �'��. �� ��. T1 � � ' ' ' � 1 WETLAND ��°�` �. '�� - . - -_, - -_ _ _� . f�-- --- - , -�� - ;�o _c � � � - CONSERVATION ����4,�Q������� � r�� .�s� ��,r� - � .�,a. ��� � �� AREA P _�..�� �_�� e- �;; �° „- �,,; _rq T ,.��i�.� �� -� �,,� �.,. � .� • /� vi � °��,_.�'�i • �6' \�• . - V�J� T � V71 ri S Q�C a' �_ -' J'�"c� � _ (1 .22) AC. -- - _. .-\ �� .�` ., -- -- 5� _ s-�"_o- 6. �� �.���v ..���-o�_.Y ��-R,r � Dc ` 9'e' Y% s Y�C .�!' 17- "_' , -- COIJ7ROL STRUCTUR�C �s- � ��O �� � �r ;,-����- . 100YRDHW=104.0 • � � .' � " ^ a � - --• . _ '•�^e ��E �,�a('' � ' 9 • '/ ""'Y6 - ` - ' `'- -- � � � �EIS CJ� IQE' c -__`o�, .�S � ' ' '0•��� \ 11� � � .-`_ . ` " ' . '__ ' S \ � . _ _ � _ ' "" '_'______'"_'_ "-_" _" ' _' __ " � . � :.�� .. , -.._..�� p/� �C p pp/� _._._.�.-.,--,.. - . . ��'_�_ UV .7f ltiVU1JLG._ . _��.__, \� ' '_ �"_�_�__' 1' ._. _�_.� - . .�R _ _ ._"__" . . _.. .__.