Loading...
HomeMy WebLinkAbout17-18521 CITY OF ZEPHYRHILLS 5335-8TH STREET , • - (sis)�so-oozo 1852 �`f BUILDING PERMIT SINGLE FAMILY RESIDENTIAL , � PERMIT INFORMATION � �LOCATION INFORMATION Permit#:18521 Issued: 5/30/2017 Address: 36089 STABLE WILK AVE Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR � Township: Range: Proposed Use: NOT APPLICABLE - .- , Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 303,551.44 Total Fees: 11,561.19 Subdivision: SILVERADO Amount Paid: 11,561.19 Date Paid: 5/30/2017 Parcel Number: 04-26-21-0070-00100-0290 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC ' Name: LENNAR HOMES LLC Addr: 15550 LIGHTWAVE DR Address: 4600 W. CYPRESS ST STE 200 CLEARWATER, FL. 33760 TAMPA, FL. 33607-4099 Phone: (727)479-1740 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2,854 SQ FT APPLICATION FEES BUILDING FEE 1,202.00 ELECTRICAL FEE 247.50 PL MBIN FEE 165.00 MECHANICAL FEE 115.50 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1°/a 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1°/a 36.32 ��G� , �� , r�� �,� ,�u _�� � 0 Ins ections Re uired FOOTER 2ND ROUGH PLUMB MIS INSULATION CEI G FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTlON FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this properly that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. ' �� � CONTRAC ORS SIGNATURE PERMIT OFFI P RMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED I PROTEGT CARD FROM WEATHER � - ,II ' ' Lennar Homes-36089 Stable Wilk Ave-2;854 sq ft �� SQ. FEET PRICE • MAIN OR LIVING: 2,854 $ 106.36 OTHER AREA UNDER ROOF: _ _ _ - $ 88.00 � -- '- OTHER: _ $ - _ � _--- VALUATION $ 303,551.44 FEE SHEET $ 1,100.00 � ADDRESS $ 40.00 DRIVEWAY $ __ 40.00 BUILDING: $ . _ 1;202.00 ELECTRICAL: $ 247.50 � PLUMBING: $ 165:00 '� MECHANICAL: $ 115.50 _ SUB-TOTAL $ 1,730.00_ T07AL $ 1,730.00 • SEWER: - na WATER: - �- na IRRIGATION: .$ - - - TOTAL: $ _ WATER METER: - na IRRIGATION METER;$ - " - -- FIRE DEPARTMENT FEES PLANS TOTAL; _ na INSPECTION TOTAL: PERMIT 70TAL � � TOTAL; ,$ - . PUBLIC SAFETY IMPACT FEES - POLICE $ � 254 00 FIRE $- 273.00 - - 5% $ 26.35 � r� TOTAL: $ 553.35 �-` SUB-TOTAL $ 2,283.35 PARK IAAPACT FEES $ 769.56 ,Cj� S1F'S: $ 4,828.00 100.0% $ 4,828.00 -- 1.0% �$ 48.28 — �� TOTAL: $ _ 4,876.28_ T I F'S: $ 3,632.00 � �i�D�� � 99% $ 3,595.68 �-� 1% $ 36.32 f TOTAL: $ 11,569.19 - - � i i��ii�iiiii�oi�i ii�ii i�iii��iii i�iii iia�iiiiii�iiiai iiii i��i , , 2017077123 Rcpt:1865620 R�c: 10.00 DS: 0.00 IT: 0.00 05/23/2017 L. 5. , Dpty Clerk PRULR S 0'NEIL,Ph D PqSCO CLERK & COMPTROLLER 05/23/2017 02:36 m 1 of 1 -- °R_BK !9�4�_P� 1��� Permit No. Parcel ID No 04-26-21-0070-00100-0290 IVOTICE OF COMMENCEMENT State of FlOflda County of PaSCO THE UNDERSIGNED hereby gives notice that imp�ovement will be made to certain real property,and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: 1 Description of Property Legal SILVERADO RANCH SUBDIVISION PHASES 2,3,&4 PB 73 PG 59 BLOCK 01 LOT 29 sc�ee�ada�e5s: 36089 Stable Wilk Avenue Zephryhills FL 33541 2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence 3. Owner Information: Lennaf Homes, LLC � Name 4600 W Cypress St. Ste 200 Tampa FL. 33607 Address City State Interestin Property� Name of Fee Simple Titleholder N�A (If other than owner) Address City State � 4 contracror Lennar Homes, LLC , Name ' 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State � Contractor's Telephone No.. 813 574.5700 5 5urety� :' �` �1/A Name Address City State Amount of Bond: $ Telephone No.. s �ender N/A � Name Address City State Lender's Telephone No. 7 Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713 13(1)(a)(7),Florida Statutes: Lennar Homes LLC " Name 4600 W Cvpress St Ste 200 Tampa FL, 33607 Address City State Telephone Number of Designated Person: 813.574.5700 B In addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner• 9 Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: �i WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1., SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA ��� COUNTY OF PINELLAS Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President _ Signatory's Title/O�ce The foregoing instrument was acknowledged before me this 2� day of MafCh p��/� ,by Steve Smith as ViCe Pfesldent (type of authority,e.g.,officer,trustee,attorney in fact)for Lennar Homes. LLC (name of alf of whom instrument was executed) Personally Known�OR Produced Identification❑ Notary Signat , Type of Identification Produced Name(Print) Elissa Holleran Verification pursuant to Section 92.525,Florida•Statutes. Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. � � �� ���r''•. ELISSAkf;yp��ERAN Signature of Natural Person Signing Above �.Cemml'dlon#FF98583T a Explros June 6,2020 wpdata/bcs/bcs form; .�0d ,�''� .6ondodThruTroyFolnlMunnoolOU�365-7pip � � �� — Y�v - �iA'��'�� FL��Ii�A, ��t&���`C�`�F PAS�� �g����p� THIS IS TO CERTIFY THAT THE FOREGOING IS A ��,� o ,�, R..'��� TRUE AND CORR�C7 CQPY a�T�iE DOCUMENT � , ' '�� ON�FILE OR�Q�.PU��IG RE�CIR�IN�i'WI'SOFFICE ,�Y d� INIT ", �M�'hiAND � FIGIALSE 2LT�,iIS 5. ."=u.a.. -- � �� � �, ��; DAY d�A �I ��� ;-; I�Goa?Ve?•;,,•r , .� P/� LA S.0'PJ�II, - :. !�' Mf�TROLLE � �;, � � �Q,: � `��� � s � �y DEPUTY CLERK , .���y � �����c'��L��`�� ' ' Lennar Homes-36089 Stable Wiik Ave-2,854 sq ft o umn SQ. FEET PRICE MAIN OR LIVING: 2,854 $ 106.36 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 303,551.44 FEE SHEET $ 1,100.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,202.00 ELECTRICAL: $ 247.50 PLUMBING: $ 165.00 MECHANICAL: $ 115.50 SUB-TOTAL $ 1,730.00 TOTAL $ 1,730.00 SEW ER: na WATER: na IRRIGATION: $ - TOTAL: $ - WATER METER: na IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: na INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,283.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T 1 F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,561.19 , 36089 Stable Wilks Ave -• o umn SQ. FEET_ PRICE UNDER ROOF: � .�, 2,854 $ 106.36 OTHER: - - $ VALUATION $ 303,551.44 FEE SHEET $ 1,100.00 ADDRESS $ 60 DRIVEWAY $ 6 . �'} BUILDING: $ 1,242.00 ELECTRICAL: $ 247.50 PLUMBING: $ 165.00 MECHANICAL: $ 115.50 SUB-TOTAL $ 1,770.00 TOTAL $ 1,770.00 SEW ER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,323.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 � TOTAL: $ , � (I� � ��� � I Single Family Dwelling Plan R i ev ew Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. - 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. 9. No electric,plumbing,mechanical, or framing shall be covered without an inspection and approval first. ' 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). � 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. � 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. II 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating � or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. All 2008 N.E.C. Codes will be enforced. 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 ' , 22. In accordance�with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. F.F.E.-Finished Floor Elevation F.B.C-Florida Building Code 5�'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008) , s�a-�ao-oozo City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Cnntact for Permittin � 813 363 __ 2891 Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700 Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name N�A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 36089 Stable Wilk Avenue LOT# 0290 SUBDIVISION Silverado Ranch Subdivision Ph 2,3,84 pARCEL ID# 04-26-21-0070-00100-0290 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED � NEW CONSTR e ADD/ALT � SIGN � � DEMOLISH INSTALL REPAIR PROPOSED USE � SFR Q COMM � OTHER TYPE OF CONSTRUCTION � BLOCK Q FRAME � STEEL 0 DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF 2854 SQ FOOTAGE 2389 HEIGHT 2 StOC')/ r-rrr-r-r- �..rr� ✓ BUILDING $ G ��p VALUATION OF TOTAL CONSTRUCTION / I�/ 'ELECTRICAL $ � PROGRESS ENERGY Q W.R.E.C. '� ` AMP SERVICE �PLUMBING $ �MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION (��� 1 � � OGAS � ROOFING Q SPECIALTY 0 OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA �YES �O Lr u -a-+-F-�-:--:--�:-:-'-�.�F-F-���F-r--E-F-�-F-�-��--���--�-�--���--��r--�:--:--r'-:--:-r-:�'-:--:-�-;--:-:-r�--���-. BUILDER COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 License# CGC1518166 ELECTRICIAN COMPANY Edmonson Electric, �IIC. SIGNATURE REGISTERED Y/ N FEE CURREN Y/N , Address 1034 Skipper Road,Tampa, FL 33613 �icense# EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y!N Address P.O Box 5308, Bayonet, L 34674-5308 �icense# CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, Bayonet, F 34674-5308 �icense# CAC058062 OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4211 Shoal Line Blvd, Spring Hill, FL 34607 �icense# CCC057991 � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ,"«`PROPERTY SURVEY required for all NEW construction. �-:..�I..i-1-1..��'.-�:��I..��I..�I..��f..1��1..f-f..l-�-1..�4.1..�1..��1..1..�-:�:..:�I..f..f-' '....�:-^1..1..4�1..1..1�'.�:..r�� Directions: Fill out application completely Owner 8 Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) "" Agent(for;the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(PIoUSurvey/Footage) � Driveways-Not over Counter if on public roadways..needs ROW � _� NOTICE OF DEED RESTRICTIONS The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES� If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009 Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting it is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to �� receiving a "certificate of occupancy" or final power release If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500 00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to � deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to� - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, WateNWastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - �� Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent ,properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating � the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVE ENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN TTORNEY BEFORE RECORDING OUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S 117.03) I OWNER OR AGENT CONT AC OR i Subscribed an by Paul Sw�ee er e before me this S�ubsc�ribe and bY Paul Sween yed)before me this I tu-iwar-i i Who is/are personally known to me r Who is/ar ersonall known to me or a identification. as identification. otary Public Notary Public Commission No. FF98537 ommission No. rF98537 Elissa M.Holleran Elissa M.Holleran Name of Notarv tvped,printed or stamped Name of Notary typed,printed or stamped � � ��1��+►lIF�IC�l1��N �""- ` �lI�A���d�i�NlV' .; ���em�i.'ae�l�f��BE,7�97 � �,.�rem�F'an���f�P�sa�� g . r ������ur���,��d �F��►k#��3u�ad���� n" ��nid�ir�'f �t?aan��a��U >>s � �. - fS�v;i�I91rr3.rr�I�dq�v�nt�t�S�Y�3{FU � �_ - C,� .� � -- ,\ �p� � � � -�A^ ^ . T ,� _ �-. �r �T TO��jO�" v '_ r � - `\NP-�u� � �} ' hDL:� • r,1 � O� �,Q ,�� �� n� � 'i- 1 . Li ie _ {r, z+' s `Dc • _ S O�1 ,� , '�p� 0,�,• y,O.� .�,�0 T.� ,^O.. ' '�d� ` G'S a _,���e - O �p ��,`L,-J- 1�p �� �' ��- �- G,�'� � _1 �..��� o`b rf /f �1 �ro r� -.`�g`c�-.��j'� � - • � '` � ,°P�� ' � . � ��� 'l O (�� 'Q /`� .} T T 7'J - __ ,\ � `\� ` ` �� \ �/� t • � Q.J ' . � i- O "�1 ,C __ . �' � �` � ♦ ���• 'J p�' � -r� , o .a . - _ _yC��� ,3- ,{ •. �'• J:ti'� � • p� o � ' �` ,� '- •. \ ' ----•- '� v p� � ' �. , n 0 i 1 1 �� � p,� �� �r� � O� �`� ��°_ . ���' -,06v f ��: pg'1 0�E-�. _ - . +a � p,�-� b� �� g� . ��J Q�(' �\V7 �-,�� ��C�` _��� ��G' 1��� _J� �gU O��' �%` �`' --_4�- _ _ • ti U•` •*���• • J �1� �9'�' � ..1�� � ' O • ;°�1 0�`7_ .,�1 �� - •-- • -_ _ �. 'l� � ��_- ���� ,�-c���\- :�"�'-�,�- • ❑ � � � --• ' • , `o,�.o�o- •o-p'n•. � ---- - - �°J .�'. '� o'� ', - - �� i- 0 �J J �`�� . `L'� - . :,=�G �,�� . .o�n'°.a��° •,•_' . -'1 -, 1�' -_ a`� °� - ���o.�p� . ;� - �' 2p, ,Q.p•�'0 • -� , „ , t �R'Q@. -�'` � � �D� ��i. ,�o-o�° 73 ' 'c_ 6 ,�' �o S a c, _ , � �' �- ��� ���� ��� ,�x•J �O�`� _,1�� �apa•o•0'p-�� ,C�` _� ;1 C ��0� o� • a� '' '`-�-- - g� - ,�937 , _� , c� ,� D��-6 °� •� ,- �� �.o� ' - '• ` " - cJ. � _ . �g � J J��- � .�,p.o-�+��c fx �.. - b� �C'� Oj ` -�r�. C`�`� �,� �, r�� ,p,� ,�+D`� '- ``�l°� � \ �� �o:p•� OD:'` Gf V 'Z. ,O1/ 1 1 �� �O� =��}�LQ �tOp:60 .�-�99.90 • ��� � Dc. ' �� �,CQ.o- � � ;� � ,-� - -` • °.� FF=1�2.1 LOT 31 ' " LO 30 �,^ � ��` a� 7 � � 0 � LOT 32 PAD=140.4 �' PA�99.9 QT 29 FF=99.70 . � ; '- O''j �� ; ' ��o FF=10 8 PAD=99.2 LOT,� ` LOT�3 AD=101.4 TYPE B �TY�'E B TYPE��, P�S9.0 FF=99_70. � rG� , 30A =� ; ,�-tl � . TYPE A/B _ -- C�• . � FF=104.0 Pk9=1021 r�- E B. LOT 27 . ��c � 4 LOT 34 '^9'�fPE A o� � L PAD=99.0 '•g �1� • .� . � �,�� � �� FF=]Q5 AD=103�3 . � _ cJ� 7YPE B c99_ � � �� � � `� � LOT 35 TYPE A� �� --- '` _---- � ---- - -__ _ ' �ra La ^2� � _ ,� ��, � �� FF=1b,6.b AD=104.8 . � , _a�-�� ,-1�SEM� - -- _ � PA9��9 ���'( ,O� - a , �. ,� � � � LOT `36 �'� TYP� A � _ - fl� „ 98 3a� - �� �• 71'PE B� �•5�� • '_ ' - O �0'1 PA�=1 Q�. �OJ � r,�� '�' �� y G\ � �°� 1 %J 98.1 B� ,�� ' F.��8.7 '� `'� ' �G � ` TYPE�,�` Q'.5' L: w ;�� � ,\� �',� a,_ , .��PG �j , j �� \ ,� ' �� •�.,. �-',a _�� ��'� _T'�" � • ,` _ 9 ,Q .'�3 .` �� _ \ ` '� � , .'�O O l� ( � _ 15 �C,\r0• , ���. :�0 i �/ rQ. � \�\\� �� �y.r' �� '�.� �� �\ -� �� � Q � '\ */, .�F=99. �L`� � �Q � � ._�` ,o- �,J ' „ �� r^ _ 8�. ,-•5 g � LQT �; , o, �. 61 � C�- � � , ' J __ ----- - _ � ` PAD=�8.9 �� - _ � � ', ��� • � �' �� _ _`1�_ r. -� �- _ _ 9 0 �� TYPE B _ ,�' � V ^h �./� ,ti ��/^ _ . . ,` '� � 1 r.. g '�� __,_ o� � 1 � '� ,_�� P 8 p�� i �1' � � • • ,•�6 _O�T ' J � O �Q� ` ^� / - . � ' n' � � '� � c-- - �=100.90 '''�� � � '� .04 gg, � _ _ , , ,,,.�' � 10' � , r-I O1_70 • o�' � : _�o o�� �, , �00.20 { +°' _ , a ' LOT 10 � �' _,� FF=1a ; AD�10110 PAD=100. LOT 9 1' rl . .. � i .n�7 ' i _ o _._.�- ' LO�F. 1 2 �E A � PAD=99-S F=100_2a '} • - b , "� �� FF=1 o3.6 PAD=T0.1_9 � n'PE b�j E A LOT,S 91 � �'-� ' ��`� �" a- �� . �' LOT 13 TYPE A -.1 � , •� � - „• � � FF=105.0 A0�1•�2-9 _,�0� ��' ' � PA.�D-99A.5 � ', �� ' �99.70 � 'i, � ` ' LOT 14 � '�'fPE A � a �- � � � '1, �c�1 LOT 2� _ ' �i � i � FF�106.4 AD=104.3 - ^6 _„� O� �'� O���� � _ PAD=99_0 _ � 8.2 C-� � LUT 15 TYPE A ,� J > > '� �• � � _�$. ., �E 9 pc,� •„�,r� \� b ,\ AD=1�•� � . '' :1 8 ` �. f= ir � ^� c�_ i „ ��; ' � '• � � TYPE�►C �� :�� - �3_5 � F-', �. i ��'",�,.� _� =- � 'g _ / , f' ',1.� O `i �o ��O C� ' � � ' •a '� �� ,f T � - - ` � - 0'1 �\ 1 ;� 7 � • ��p� , � O� �cs K 4�� FF=10a.34.' g_ D�'1 ,� �O !qti. � , � i �'� � s- �`'�'• LOT 24�', � �� n,a• 1� ry ��t O6_ ' '� V L'. '� `�?� �� 6 , PTYPE B6 � �aro 1 Q�' - 6 !.�' S,,r j� � \1 .�� � �1s o �� .. FF=1 D6.2 � LOT 55 � FF=105.00 /,� -�� �� y i� a, _ 5`. � � o �� LDT 6 ie-c� -{� � .e, p�• . � =104: 0 � � °J' . ., `.i �, � �� , LOT 4 � PAD=105.0 � �o � - , - i �?�' , ' � ^ �� ,�- '• , -; FF=107. PAD=1D5.5 .�2YPE B � PAD=�B.3 PAD�1 7 6 � .�.� / o� � ' 11A _ �'i., m � ^ - �0 1 N� LOT 3 � TYPE B '�, � �o � C, �r 1 FF=102.40 g, • _ '���' � �r ^ �^ \ �� a FF=t07_7 AD=106 � � NP � � °' ^ C � p��. �' �� � `U• LOT 23 , i � � � ^1� �i 61 C7 � ' ,0� LOT� 2 TYPE 6 -.a "� _ �0 �Y � a ' .e P 100.7 - • ;�� p 1T� , --�` � FF-tfTB 0 AD=107i� " . 1' � B .n�g '� `�' � LOT 1 7YPE B. '� ---- �Q• ;�g '� ^ o ,. ` .��}� � _ '� .o • , � - ., -.. . 4 _ ca � 1 � ph�=7 07.3 • � _ � � � ,Q�� - _ � / � Ar�^ �CT � , T / r0.� � fiYPE B � 'ti 1 1 1 � 1 _ - � , � - � . a � ; � � , ��- � �� , �� • � - �ds£uENT _ - ,� O,�` � . � �O , i 1.02.30 � ' b�� - , ' n�•riT �� m"Y�, 99. , �._ ' --� � � (_ _. _ '4 FORM R4Q5-2Q14 FLORIDA ENERGY EFIFICIENCY �ODE FOR BUILDINt3 CONSTRUCTION Florida Department af.Bttsiness and Prafessianal Regulation - Residential Perfarmance Me#hod Project Name: 2386 sf ADS Buiider Name: Lennar Homes street: 36089 Sfiable Wilk Avenue Perm�t o�ice: ��t�f�ephyrhills City,State,Zip: ,F�, Permit Number �'fi Owner• �ennar Homes ,lurisdiction: 611600 Qesign Location: FL,Tampa 1 New construction or existing New(From Plans) 9. Wall Types(2570.5 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Waod,E�cteriar R=11.0 1285.70 ft2 b.Concrete B�ock-Int Insul,E�erior R=4.1 1118.00 ft� 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.p 166.83 ftZ 4 Mamber of Bedroams 5 d��TA R= ft� 5. Is this a worst case? Yes 10.Ceiling Types (1272.0 sqft.) Insulation Area 2 a.Under Attic(Vented) R=30.0 1120.00 ft 6. Canditioned flaor area above grade(ft2} 2389 b.Knee WaII{Vented) - R=34.0 '[52.00 ft2 Conditioned floor area below grade{ft2) 0 c.N/A R= ft' 11 Ducts R ftZ 7, Windaws�168A sqft.) description Area a.Sup:Attic,Ret:2nd Floar,AH:2nd Fioar & 477.8 a. U-Factor Dbl,U=0.54 96.00 ftx SHGC: SHGC=4.31 b. U-Factor� Db(,U=d.56 38.68 ft2 12.Cooling systems kBtuthr E�ciency SHGC: SHGC=0.28 a.Central Unit 43.5 SEER:15.50 c. U-Factor. Dbl,U=0.56 33.33 ftz SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency " d. U-Factor N/A ftz a.Electric Heat Pump 43.5 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Rrea Weighted Average SHGC: 0.345 14 Hot water systems 8. FloorTypes�(1269.0 sqft.) Insulation Area a.Electric Cap:40 ga[Ians EF 0.950 a.Slab-On-Grade Edge Insulation R=0.0 1289.00 ft� b. Conservation features b.NlA R= ft2 Nane c.N/A R= ftz 15.Credits Pstat Glass/FloorArea: 0.070 Total Proposed Modified Laac3s: 67.32 ��c� Total Baseline Loads: 69.61 �� i here6y certify that the plans and specifications covered by Review of the plans and �.�'tli�ST��.�, . this calcutafion are in compiiance with fhe Florida Energy specifications cavered by this �, , . '�.4., C7 Code. calculation indicates compliance ��<,,,4'f� '-;=;.`;�..�` �'�, ��v� ���L l. with the Florida Energy Cade. .� rr�c,�'';�:4�';.;°,;°ri`�,'�°`;���� PREPARED BY� p +�,t YL Before constructian is com leted ��., �.�r, � ' d DATE: this building will be inspected far � '"'�� j ; �. campliance with Sectian 553.908 # � � " I hereby certify that this building,as designed, is in campliance Flarida Statutes. �, ", ' ���,. with the Flarida Energy Code. _ `�Q,t3 y�E"1� OWNER/AGENT: BUILDING OFF I DATE: QATE: ' '" - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factary-seaied in accordanoe with E2+iO3.2.2.1. -Compliance requires an Air Barrier'and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage - test report in accordance with R402.4.1.2. - Comptiance with a proposed dact leakage Qn requires a Duct Leakage 7est Report confirming duct ieakage to outdoors, tested in accordance with Section 803 of i2ESNET Standards,is not greater than 0.030 Qn for whole hause. ' 12/30/2016 12:15 PM EnergyGauget�USA-FlaRes2014 Sectian Rd05.4.1 Compliant Software Page 1 of 4 � L t FORM R405-2014 FLGIRIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Flarida Department af Business and Prafessional Regu}ation - Residential Perfarmance Method Project Name. 2386 sf AD5 Suilder Name: Lennar Hames streec: 36089 Stable Wilk Avenue Permit ot�ice: City of Zephyrhills City,Stafe,Zip: ,F�, Permit Number� Owner• �ennar Homes ,lurisdiction: 611600 Design Location: FL,Tampa 1 New construction or existing New(From Plans) 9, Wall Types(2570.5 sqft.) Insulatian Area 2. Single family or multiple family Single-family a.Freme-Wood,Ea�teriar R=11.0 '1285.7Q ft2 b.Concrete Block-int Insul,Exterior R=4 1 1118.00 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.p 166.83 ftZ 4. M1tumber of Bedraoms 5 �•NlA R= ft� 5. Is this a worst case? Yes 10.Ceiling Types (1272.Q sqft.) Insulation Area 2 a.Under Attic(Vented) R=30.(] 112�.00 ft 6. Conditioned floor area above gcade(ftz} 2389 b.Knee WaIE(Vented} R=30.Q 152.00 ftZ Conditioned floor area below grade{ft2) 0 c.N/A R= ftZ 11 Ducts R ft� 7, Windows{168.0 sqft.) Dascription Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 477.8 a. U-Factor: Dbl,U=0.54 96.00 ftx SHGG: SHGC=Q.31 b. t)-Factor Dbl,U=0.56 38.68 ffz '�2.Caating systems kStulhr Efficiency SHGC: SHGC=0.28 a.Central Unit 43.5 SEER:15.50 c. U-Factor Dbl,U=a.56 33.33 ftz SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor N/A ft2 a.Electric Heat Pump 43.5 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.345 14 Hot water systems 8. FloorTypes (1269.0 sqftJ Insulation Area a.Eleetric Cap:40 gaElans EF.0.950 a.Slab-On-Grade Edge lnsulation R=0.0 7269.00 ftx b. Conservatian features , b.M1A �= ft2 None c.N/A R= ftz 15.Credits Pstat Glass/Floor Area: 0.070 Total Praposed Modified Loads: 67.32 pASS Tota! Baseline Loads: 69.61 I hereby certify that the plans and specifications covered by Reuiew of the ptans and �'�� '���',r�?. • this calcu}afion are in campiiance with the Florida Energy specificafions covered by this ` 4r� '� _ -. ,,�t�,� Gode. calculation indicates compliance r,s'��''>�,�;''j� �;;'�.� � 1,t /, ' +t*' rt��(c._,,,,,,k;:. a`�,+•�"` �. ���E-�wt{'��VG with fhe Florida�nergy Code. "�`�` �`"�.,:�+�,,, Q PREPARED BY: Before construction is completed w •�-t ' �' � DATE: this building will be inspected for � '�' �`j�� ; �� : ,�,� . compliance wifh Sectian 553.90$ _.f � I hereby certify that this building, as designed,is in compliance Florida Statutes. .�+,�,� ,." ���: with the Florida Energy Cade. 4D��"� OWNER/AGENT. - BUILDING FI IAL. DATE. DATE. - Compliance requires certificatian by the air handler unit manufacturer that the air handler enclosure qualifies as certRfied factcsry�ealed in accardance wifh R403.2.2,1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accardance with R402.4.9.2. � - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of FtESNET Standards,is not greater than 0.030 Qn for whole house. 12/30/2016 12:15 PM EnergyGaugeO USA-FlaRes2014 Section R405.4,1 Compliant Software Page 1 of 4 : � FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department af Business and Prafessianal Regulatian - Residential Pertormance Method Project Name: 2386 sf ADS - Builder Name: Lennar Nomes street: 36089 Stable Wilk Avenue Perm�t ot�ce: City of Zephyrhills Cify,State,Zp: ,F!., Permit Number• Owner Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa 1 New construction or existing New(From Plans) 9. Wall Types(257Q.5 sqft.) Insulation Area 2. Single family or mulfiple family Single-family a.Frame-1Naod,E�cteriar R=11.0 9285.74 ft2 b.Concrete Biock-Int lnsul,EMerior R=4.1 1118.00 ft= 3. Number of uni#s,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 166.83 ft' - 4 Number of B�droams 5 d.htA R= ftZ 5. Is this a worst case? Yes 1 q,Ceiling Types (1272.0 sqft.) Insulation Area � a.Under Attic(Vented) R=30.0 1120.00 ft 6. Conditioned floor area above grade{ft2) 2389 b.Knee WaII{Vented) R=30.0 'E52A0 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ 11 Ducts R ft2 7, Windows{168.0 sqft.} Descsiption Area a.Sup:Attic,Ret:2nd Fioor,AH:2nd Ftaor 6 47Z8 a. U-Factor Dbl,U=0.54 96.00 ftx SFiGC: SHGC=4.31 b. U-Factor dbl,U=0.56 38.68 ft2 12.Cooling systems k8tuthr Efficiency SHGC: SHGC=0.28 a.Central Unit 43.5 SEER:15.50 c. li-Factae. D61,U=0.56 33.33 82 SHGC: SHGC=0.32 13.Heating systems kBtulhr Efficiency d. U-Factor� N/A ftz a.Electric Heat Pump 43.5 HSPF:9.OD SHGC: Area Weighted Average Overhang Depth. 1.000 ft. Area Weighted Average SHGC: 0.3Q5 14 Hot water systems 8, Floor Types (1269.0 sqft.) Insulation Area a.Eiectric Cap:40 gallons EF 0.950 a.Slab-On-Grade Edge Insulation R=0.0 1269.00 ft2 b, Conservation features b.N1A ft= ft2 None c.N/A R= �z 15,Credits Pstat Glass/Floor Area: 0,070 �btal Praposed Modified Loads: 67.32 pASS Total Baseline Loads: 69.61 i hereby certify that the plans and specificaYians covered by Review of the plans and ���:ST��, this calcu}ation are in compliance with fhe Florida Energy specifications covered by this �v�-:.� '_,�,;'�'Q4,�, Gode. calculation indicates compliance ��rr,�°'' � ='_,�`,•w`.�� j}j� /� flt1/��t/�j��j with the F(orida Energy Code. ` -`'�',. '�`� � ll/V4�C/ T1Wi/!V/4 �"�� tFt3{j��ib%;%^;i�,'`��yt��. PREPARED BY' Before cons#ruction is campieted w ��� '`' � G1ATE: this building will be inspected for �j "��;�_'�" � camptsance with Secfion 553.948 �" ���"�- �� �- � I hereby certify that this building,as designed, is in compliance Flarida Statutes. �t�,, ' ��+�. with the FlQrida Energy Code. �t?,t?��+yE"'� OWNER/AGENT: BUILDING QFFIC�L. DATE: DATE. "z --Comgliance reyuires certification by the air handler unit manufacturer that the air handler enclosure qualifies as � certified factory-saated in accortfance with R403.2.2.1. ' -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.7.2. - - Compliance with a proposed duct ieakage Qn requires a Duct Leakage Test Report confirming dvct leakage ta outdaors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole hause. 12/30/2016 12:15 PM EnergyGauget�USA-FlaRes2Q14 Section R405.4 1 CompliaM Software Page 1 of 4 � FORM R405-2014 PROJECT � Title: 2386 sf ADS Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 2389 Lot# Owner• Lennar Homes Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name. Lennar Homes Rotate Angle: 45 Street: Permit O�ce: Cross Ventilation. County Pasco Jurisdiction: Whole House Fan: City,State,Zip: , Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp \/ Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range ,I FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium I BLOCKS Number Name Area Volume 1 Blockl 2389 19873.4 SPACES Number Name Area � Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 1st Floor 1269 10913.4 Yes 2 1 1 Yes Yes Yes 2 2nd Floor 1120 8960 No 4 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 121 ft 0 1269 ftZ � 0.3 0 0.7 ROOF � Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor Tested Tested Insul. (deg) 1 Hip Composition shingles 1213 ft= 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1120 ft� N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 UnderAttic(Vented) 2nd Floor 30 1120 ft= 0.11 Wood 2 Knee Wall(Vented) 2nd Floor 30 152 ft2 0.11 Wood 12/30/2016 12:15 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 � � FORM R405-2014 WALLS Adjacent SPa� Cavity Width Height Sheathing Framing Solar Belo w _ 1 N=>NE Exterior Concrete Block-Int Insul 1st Fioor 4.0999 10 8 8 86.7 ft� 0 0.600000 0 _2 E=>SE Exterior Concrete Block-Int Insul 1 st Floor 4.0999 52 8 8 450.7 ft2 0 0.600000 0 _ 3 S=>SW Exterior Cancrete Block-Int Insul 1st Floor 4.0999 30 8 8 260.0 ftZ 0 0.600000 0 _4 W=>NW Exterior Concrete Block-Int Insul 1 st Floor 4.�999 37 8 8 320.7 ft2 � 0 �.600000 0 _5 N=>NE Garage Frame-Wood 1 st Floor 11 19 3 8 8 166.8 ftz 0 0.01 0 _6 W=>NW Exterior Frame-Wood 1st Floor 11 14 6 8 8 125.7 ft' 0 0.01 0 _7 N=>NE Exterior Frame-Wood 2nd Floor 11 18 6 8 148.0 ft' 0 0.600000 0 _ 8 E=>SE Exterior Frame-Wood 2nd Floor 11 52 8 416.0 ft2 0 0.600000 0 _ 9 S=>SW Exterior Frame-Wood 2nd Floor 11 30 S 240.0 ft2 0 0.600000 0 _10 W=>NW Exterior Frame-Wood 2nd Floor 11 44 6 8 356.0 ftZ 0 0.600000 0 ' DOORS # Ornt Door Type Space Stortns U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated 1st Floor None .2 3 6 8 20 ft� 2 N=>NE Wood 1st Floor None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => chan ed to Worst Case. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening ' 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 6.7 ft� 1 ft 0 in 10 ft 4 in Drapes/blinds None 2 E=>SE 2 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 1 ft 0 in 10 ft 4 in Drapes/blinds None 3 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 1 ft 0 in 10 ft 4 in Drapes/blinds None 4 S=>SW 3 Metal Low-E Double Yes 0.56 0.32 33.3 ft' 1 ft 0 in 1 ft 4 in Drapes/blinds None 5 N=>NE 7 Metal Low-E Double Yes 0.56 0.28 16.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None 6 E=>SE 8 Metal Low-E Double Yes 0.54 0.31 16.0 ft' 1 ft 0 in 0 ft 6 in Drapes/blinds None 7 S=>SW 9 Metal Low-E Double Yes 0.54 0.31 16.0 ft= 1 ft 0 in 0 ft 6 in Drapes/blinds None 8 W=>NW 10 Metal Low-E Double Yes 0.54 0.31 32.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None 9 N=>NE 7 Metal Low-E Double Yes o.56 0.28 16.0 ft' 1 ft 0 in 3 ft 0 in None None GARAGE # FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 414ftZ 384ft' 45ft 8.6ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000264 1656.1 90.92 170.99 244 5 , 12l30/2016 12:15 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 � I I • � . FORM R405-2014 � HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:9 43:5 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:15.543.5 kBtu/hr 13�5 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 90 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage • Cert # Company Name System Model# Collector Model# Area Volume FEF None None g2 DUCTS / —Supply— —Retum— Air CFM 25 CFM25 HVAC# \� # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 477.8 ft 2nd Floor 119.45 Prop.Leak Free 2nd Floor —cfm 71.7 cfm 0.03 0.60 1 1 TEMPERATURES Programable Thertnostat:Y Ceiling Fans: Coolin Jan Feb Mar A r Ma X Jun Jul Au [X]Se Oct Nov Dec Heatin9 Jan Feb Mar E �APr f �May 4 �Jun ��Jul" ��Au9 [ ]SeP f �Oct �Nov f X�Dec Ventin Jan Feb Mar [X A r [ Ma [ Jun Jul Au [ ]Se [X Oct Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 , .10 11 12 Cooling(V11D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 SO 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(V11D) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(V11EH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 12/30/2016 12:15 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 . • FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPertormance Index, the more efficient the home. , , FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1285.70 ft2 b.Concrete Block-Int Insul,Exterior R=4 1 1118.00 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 166.83 ft2 4 Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? 10.Ceiling Types Insulation Area Yes a.Under Attic(Vented) R=30.0 1120.00 ft� 6. Conditioned floor area(ftZ) 2389 b.Knee Wall(Vented) R=30.0 152.00 ftz c.N/A R= ft2 � 7. Windows" Description Area ��,Ducts R ft2 a. U-Factor• Dbl,U=0.54 96.00 ft� a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 477.8 SHGC: SHGC=0.31 b. U-Factor Dbl,U=0.56 38.68 ft2 SHGC: SHGC=0.28 12.Cooling systems kBtu/hr Efficiency c. U-Factor Dbl,U=0.56 33.33 ft2 a.Central Unit 43.5 SEER:15.50 SHGC: SHGC=0.32 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 43.5 HSPF:9.00 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.305 8. Floor Types Insulation Area 14 Hot water systems : a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1269.00 ft EF 0.95 b.N/A R= ftZ c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building - ;�K��r Construction through the above energy saving features which will be installed (or exceeded) of . _ g�'� . ' in this home before final in pection. Otherwise, a new EPL Display Card will be completed � k'�'�'`'' ��`;�.;���:, c� �: , . --.� �;,. .c� base d on ins ta l le d Co de c mp lian t fea tures. � +r;r.,�.��%.,•�;.�°��;;:•�u;,�� � :�...:��;t�....r � � C7 Builder Signature: Date: 03/22/17 �� }�4=�� � � �° � Address of New Home. 36089 Stable Wilk Avenue City/FL Zip: Zephyrhills,FL 33541 '�� � .��' o�yv�"�' *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 12/30/2016 12:16 PM EnergyGauge�USA-FlaRes2014 -Section R405.4 1 Compliant Software Page 1 of 1 BV��d�ng Ana�y$�$ , Job: 2386sfADS � Date: 3I22/2017 Entire House By: Dave , BAYONET PLUMBING COOLING HEATING - ' • - � • For• Lennar Homes � - • • � • Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (�F) 39 16 Latitude: 28°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ftz Btuh % of load Walls 4 7 11412 35.5 Glazing 30.2 5199 16.2 Doors 23.5 480 1.5 Ceilings 1.3 1611 5.0 Floors 4.0 5059 15.7 Infiltration 1.7 4365 13.6 D ucts 4025 12.5 . Piping 0 0 ,� Humidification 0 0 Ventilation 0 0 m, Adjustments 0 �' `�` Total 32151 100.0 • • Component Btuh/ft2 Btuh % of load Walls 2.8 6736 20.1 Glazing 46.6 8029 23.9 Doors 18.4 376 1.1 `�°� Ceilings 17 2175 6.5 Floors 0 0 0 . Infiltration 0.4 972 2.9 ' D ucts 4489 13.4 Ventilation 0 0 Internal gains 10760 32.1 � � Blower 0 0 Adjustments 0 � Total 33538 700.0 � � �, � Latent Cooling Load= 5229 Btuh Overall U-value= 0.117 Btuh/ftZ-°F Data entries checked. .` WI'1 f1tSOft` 2017-Mar-2214:33:39 .••►_ � g Right-Suite�Universal 2013 13.0.09 RSU05714 Page 1 �` H:\LENNAR LOADS�2386 sf ADS 3.5 tan.rup Calc=MJ8 Frant Door faces: S Project Summary Job: 2386sfADS Date: 3l22/2017 Entire House By: Dave BAYONET PLUMBING COOLING HEATING ' • - • • For Lennar Homes Notes: , - s e e Weather. Tampa International AP, FL, US II Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db ._91 °F ' Inside db 70 °F Inside db 75 °F Design TD 39 °F Design TD 16 �F Daily range L, Relative humidity 50 % Moisture difference 55 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 28126 Btuh Structure 29048 Btuh Ducts 4025 Btuh Ducts 4489 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32151 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 33538 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 4417 Btuh Ducts 812 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area(ft2 2389 2389 Equipment latent load 5229 Btuh Volume�ft') 21698 21698 Air changes/hour 0.28 0.15 Equipment total load 38766 Btuh Equiv.AVF (cfm) 101 54 Req. total capacity at 0.85 SHR 3.3 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-042-230-18 Cond 14HPX-042-230-18 AHRI ref 5187377 Coil CBX27UH-042-230*++TDR AHRI ref 5187377 Efficiency 9 HSPF Efficiency 13.0 EER, 15.5 SEER Heating input Sensible cooling 36975 Btuh Heating output 43500 Btuh @ 47°F Latent cooling 6525 Btuh Temperature rise 28 °F Total cooling 43500 Btuh Actual air flow 1400 cfm Actual air flow 1400 cfm Air flow factor 0.044 cfm/Btuh Air flow factor �.042 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .�. WCI htsoft" 2017-Mar-2214:33:39 g Right-Suite�Universal 2013 13.0.09 RSU05714 Page 7 � H:\LENNAR LOADS�2386 sf ADS 3.5 ton.rup Calc=MJ8 Front Door faces: S Manual S Compliance Report Job: 2386sfADS Date: 3/22/2017 . En fire Ho use By: Dave BAYONET PLUMBING COOLING HEATING ' o - s s For• Lennar Homes • s e • • Design Conditions Outdoor design DB. 91.3°F Sensible gain: 33538 Btuh Entering coil DB� 75.6�F .Outdoor design WB: 77.3°F Latent gain: 5229 Btuh Entering coil WB. 62.8°F Indoor design DB: 75.0°F Total gain: 38766 Btuh Indoor RH: 50% Estimated airflow� 1400 cfm Manufacturer's Performance Data atActual Design Conditions Equipment type: SpIitASHP Manufacturer: Lennox Model: 14HPX-042-230-18+CBX27UH-042-230*++TDR Actual airtlow: 1400 cfm Sensible capacity� 36975 Btuh 110% of load � Latent capacity: 6525 Btuh 125% of load Total capacity� 43500 Btuh 112% of load SHR. 85% • a a Design Conditions Outdoor design DB: 30.8°F Heat loss: 32151 Btuh Entering coil DB. 69.7°F Indoor design DB. 70.O�F Manufacturer's PerFormance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer• Lennox Model: 14HPX-042-230-18+CBX27UH-042-230*++TDR Actual airtlow: 1400 cfm Output capacity: 43500 Btuh 135% of load Capacity balance: 31 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a � Actual airflow: 1400 cfm Output capacity� 0 kW 0% of load Temp. rise: 0 °F The above equipment was selected in accordance with ACCA Manual S. .` wri htsoft` 2017-Mar-2214:33:39 �, 9 Right-Suite�Universal 2013 13.0.09 RSU05714 Page 1 �'� H:\LENNAR LOADS\2386 sf ADS 3.5 ton.tup Calc=MJ8 Front Door faces: S 04-26-21-0070-00100-0290 � Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Wednesday, May 24, 2017 Parcel ID 04-26-21-0070-00100-0290 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $26,530 TAMPA FL 33607-4099 • Building $p Physical Address Extra Features $0 36089 STABLE WILK AVE ZEPHYRHILLS, FL 33541 ]ust Value $26,530 Legal DeSCriptiOn (First 4 Lines) ASSessed (Non-School Amendment 1) $26,530 SILVERADO RANCH SUBDIVISION PHASES 2, 3 &4 PB 73 PG 059 BLOCK 1 Taxable Value $26,530 LOT 29 Jurisdiction City of Zephyrhills __ Land Detail (Card: 001 of 001) ; --- , --r--�__ Line �Use � D se criptionZoning iUnits �Type �Price __�Condition_�Value I 1 1 0100 �_ SFR � MPUD ��6,000.00 SF 4.40 � 1.00 $26,400 - - --, ----- ---�---- -�--- � � 2 0100 SFR MPUD 393.00 � SF � � � � , � $0.33 �1.00 � $130 Additional Land Information ------ � -� `_ Acres 0.15 Tax Area 30SI �C de ( -- � Residential Code� SLVRCPI Building Information - Use 00 - Unimproved (Card: 001 of 001) ' Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line � �Descr—i tion Year lUnits �Value ____._________L--p�_------L----- - ----�- - No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year�Book/Pa e �T e -_________T.____ ___.��_._�__________._ __ _ g____�_yp ;DOR Code Condition (Amount _ ----- ----7 --- ' - 05/2017 9544/ 0893 ; Warranty Deed 05 Vacant Multi-Parcel Sale -------------- - ----L----—___._.. �__�._ _� _ 09/2011 8606 / 3376 _ � Warranty Deed 05 Vacant � Multi-Parcel Sale 05/2010 8373 / 1912 i Certificate of Title �Y 12 � Vacant � $0 http://search.pascopa.com/parcel.aspx?parce1=2126040070001000290 5/25/2017 'I � � LE N lel /� 1�� ' - August 22, 2017 City of Zephyrhills-Building Department 5335 8th Street Zephyrhills, FL 33542 813-780-0020 Re: Authorization Letter I,Steve R.Smith, Florida State License number CGC1518166 hereby authorize the following individual to sign on my behalf,to pull permit,to pay all fees,to obtain certificates of occupancy's, on all of Lennar Homes- LLC permitting and construction related needs. This letter supersedes all others. Please remove any and all other authorized representatives from any previous letters and please maintain this letter as your only reference for authorized representatives for my license. • Paul Sweeney • Christopher Smith • Rob Christy • Suncoast Permits • Ashlee Callahan • Tad Thaxton • Elissa Holleran • Elmer Bennett • Stephanie Farmer Business Address: 4600 W Cypress Street, Suite: 200,Tampa, FL 33607 Business Phone: 813-574-5743 Business Fax: 813-574-5703 If you have any questions or need to contact me at any time, please reach me at 813-574-5740. Sincerely, �� Steve R. Smith Lennar Tampa Director of Construction Who is personally known to me, , Sworn and subscribed before me this o� day of 2017. ����Y�,�':;�Commissioo#GG 077910 ' ��:ExptresApd121,2021 a�,7o19 ��. '%','�°l;Z��° ga�edTlvuTmyfafnlnswmxe _ Not ublic 460o West Cypress Street Suite zoo Tampa,FL 33607•Phone:8i3-574-5700•Fax:8i3-574-5703 LENN/�1R.COM �_ . a ;�j PASCO COUNTY� ,_..�a { BUILDING CONSTRUCTIOfd SERVICES ' y�i`� 8731 Citizens.Driye Date:7/28l2017 Y ; . � . Suite 230 �r ' New Port Ricfiey;.FL,34654 . �,' �, 727-847=8127 �:� 1 04�� � �����'4�d'� 1 �� � Receipt'.#: 1696360 FEE DESCRIPTIOPI ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT�t DA'TE Impact Fee.Resideritial Solid 8450-383000. 27.88 1273683 $27_SS. $27.88 1696380 7/28%.17 Waste Single Family TOTALS: $27.88 '$27.88 Receiat# Paid B Check# CC Auth# Cashier ID. Workstation ReceiafDate Amt Raid.. 1896380 Check 881847 294 BCCCP38W 07/28/2017 $27.88, Total.Payments: $27.88 Pavor Address Phone lennar Commenfs• 36089 STABLE WILK AVE ZMILLS SOLID 1NASTE RYMNT PERMIT#'18521„ . 'r - ; . _ . 02895'856 Lennar Homes,LLC JPMorgan Chase.Bank N.A. STUB GHEGK7V0. ,881847 I trNoicE � 900000.-1010:114 1, of' '1 `DATE'U7%20/.�17 CO,fl: NUMBER - '.DATE= PAYMENTADYICE.. _ GROSS DlSCOUNf - NEf' ; � 15224:, 1 52247-20 1 29.401435 071017 1522472Q12940]435 , � $27.88�. �0.00: $27c88 , ._,� ' ; , ` , � � � � � _ {S �' ,� � - � � !� t �� � ��. - , . �- � ; ..,y , _ , ��' . -j -�1�. � . - t: � v`� � ::� _ - � �� i1'� . ��`�� �" - , ��_ • � � !:'! , , ' �� 6620202' CiryofZephyrhills - FBA".Tcudy!Bihm49-81"44i' -- , �' $27.88 - - — $0.00 527.88 5335 8tli Street . ' "-' h"rhills F[.33542 " ` '� / -— , � - - j !„ MyReports[reports//PRODUCTION/PASCO/ReceiptPOS V4.rp1 7I28/2017 P,age 1 of 1