HomeMy WebLinkAbout17-18550 CITY OF ZEPHYRHILLS
. ` 5335-8TH STREET
(813)780-0020 18550 �
BUILDING PEI�MIT
PERMIT INFORMATION �- � --= LOCATION INFORMATION
Permit Number: 18550 Address: 38130 PRETTY POND RD
Permit Type: ACCESSORY BLDG. ZEPHYRHILLS, FL.
Class of Work: SHED INSTALLATION Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Square Feet: Subdivision: CITY OF ZEPHYRHILLS
Est. Value: Parcel Number: 35-25-21-0010-07100-0000
Improv. Cost: 6,500.00 OWNER INFORMATION
Date Issued: 6/06/2017 Name: AH ZEPHYRHILLS LLC
Total Fees: 105.00 Address: 1 TOWNE SQ STE 1600
Amount Paid: 105.00 SOUTHFIELD MI 48076-3728
Date Paid: 6/06/2017 Phone: 813-779-4501
Work Desc: CONSTRUCT 12 X 20 SHED
CONTRACTOR S APPLICATION FEES
GRIFFIN CONSTRUCTION BUILDING FEE 105.00
/� `_
�1
�
Ins ections Re uired - �
FRAME I
SHEATHI I
FINAL i
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
�
local overnment shall im ose a fee of four times the amount of the fee im osed for th i '
II 9 p p e rntial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.
NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applic�ble to this properly that
may be found in the public records of this county, and there may be additional permits required frorp other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney I
' before recording your notice of commencement." I
Complete Plans,Specifications Must Accbmpany Ap lication.All work shall be erformed in accordance with
P p
Ci Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
��. ,l/
C NTRACTO ' IGNATURE PERMIT�OFFI R
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE ItEQUIRED
PROTECT CARD FROM WEATHER
a��-�ao-oozo City of Zephyrhills Permit Application Fax-813-760-0021
� Building Department
Date Reeelved V � �/ Phone ContactTor Permlttln 352 206 1831
Owner's Name ��'1�n House Senior Livlug Communitles-Zepyhyhilis Owner Phone Number 813a79-i501
OW�ef's AddfeSS 38130 Prctty Pond Rd.,Zephyrhiils,FL 33540 Owner Phone Number
Fee Slmple Tltleholder Name American xous� Owner Phone Number
Fee Simple Tltlehotder Addresa r/A
JOBADDRESS 38130PrettyPondRd,Zcphyrhllls,FL335�f0 LOT$ �
SUBDIVISION �10 PARCEL ID� 3525-21-0010-07100.0060
(OBTAINED FROM PROPFATY TAX NOTICE)
WORK PROPOSED B NEW CONSiR e ADD/ALT Q SIGN Q Q DEMOLISH
INSTALL REPAIR
PROPOSEDUSE Q SFR Q COMM � OTHER StoraReShed
TYPE OF CONSTRUCTION Q BLOCK Q FRAME 0 STEEL Q
DESCRIPTION OF WORK �- � ��
BUILDING SI2E 12':20' � SQ FOOTAGE 2to' HEIGHT 8'0)^
QBUILDING $ VALUATIONOFTOTALCONSTRUCTION
6500.00
QELECTRICAL $ AMPSERVICE Q PROGRESSENERGY Q W.R.E.C.
n/a
QPLUMBING $ � �`"��
n/n /�l �
QMECHANICAL $ VALUATION OF MECHANICAL INSTALLATION n//�/' rVN'
n/a �l6!'/' � i
/ j�//[��
QGAS Q ROOFING Q SPECIALTY 0 OTHER � /�� �
(l,.i
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA QYES NO
BUILDER , > ��COMOPANY Griflin Construetion,LLC
SIGNATURE // � � REGISTERED Y/ N FEECURRE� Y!N
Add�@SS 11932 Duck Lake Canal Rd,Dade City,tL33525 LIce�59# CBC1260668
ELECTRICIAN COMPANY
SIGNATURE REGISTERED Y/ N FEECURRE� Y!N
Address License�
PLUMBER COMPANY
SIGNATURE REGISTERED Y/ N FEECURREA Y/N
Address License#
MECHANICAL COMPANY
SIGNATURE REGISTERED YI N FEECURREI. Y/N
Address License#
OTHER COMPANY
SIGNATUAE REGISTERED Y/ N FEECURRE� Y/N
Address License#
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 I
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Pertnit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construdion Plans,Storrm✓ater Plans w/Silt Fence instalied,
SanRary Facilities 81 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)wmplete sets of Building Plans ptus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new conshudion.
Minimum ten(10)working days after submittal date. Required onsite,Construdion Plans,Stormwater Plans w!SiH Fance installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projeds.All commercial requirements must meet complianca i
SIGN PERMIT Attach(2)sets of Engineered Plans.
•"•PROPERTY SURVEY required for all NEW construction.
Dlrectlone:
FII aut application completely.
Oumer&ConVador sign back of appliption,notarized
If over 52500,a Notice ot Commencement Is requlred. (A/C upgrades over S7500)
'• Agent(for the conVador)or Power of Attorney(for the owner)would be someone with notar'¢ed letter from owner authorizing same
OVER THE COUNTER PERMIT'fING (copy of contract require�
Reroofs'rf shingles Sewers Service Upgrades AIC Fances(PIoUSurvay/Footaga)
D�Iveways-Not over Counter'rf on public roadways..needs ROW
' � NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to°deed°restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work,they may be required to be licensed in accordance vvith state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the"contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County
TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands,that such fees, as may be due, wiil be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County WatedSewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide°prepared by the Florida Department of P�griculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owne�'prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be pertormed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other govemment agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. 5uch agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands,WatedWastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Aftering
Watercourses.
- Army Corps of Engineers-Seawalls,Docks,Navigable Waterways.
- Department of Heafth & Rehabilitative Services/Environmental Health Unit-Welis, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection F{gency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone°V"unless expressly permitted.
- If the fill material is to be used in Flood Zone °A", it is understood that a drainage plan addressing a
"compensating volume"wiil be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Fiood Zone "A" in connection with a permitted building using stem wall
construction,I certify that fill will be used only to fill the area within the stem wall.
- If fi(I material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill,an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. i understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel,alter,or
set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension
may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned.
����„�a�� WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
:�Y��s •+aor,� PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
:o �: WITH YOUR LENDER OR AN ATTORN Y BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. �o
'" C� FLORIDA JURAT(F.S.11 ) d //�I o `o cv �
090 ��'��0�, ��vf/`� V✓ / � 0 K
'�.,� . ��.• O W N E R O R A G E N T C O N T R A C T O R . `o c�
�"""'��� Subscribe a swor o(or a �rme b for e this bscribed and sworh (or affir d� re me this W d p LL
� z A�/i 2�.�m� ,P� �-r;`''�tn b �. _ � y �
o� � 1MYo isJa ersonally known me or has/have produced Wh is/ ersonally me or has/have produced W � � ik
3 p � as identification. as identification. a� X o
� 3 � N F � W ul
N 3 c m y a E E
� � �' S � NoNary Public Notary Public � v o
m V
0
T y d = ' Commission No. Commission No. Z �
� � �° � Nunrp..
tn � ..c. 9 -••`��`� �0�..
�OD T Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped :Q�O �'► boz
N N O => LL'
� O � �R6 0:
OD � '�O r�* �"
i 7, �`��•
�Ai�.��,'�
s„ �. �._
'�T ��'�'�4�,�`" � �
-__.-_._--- _.._.____----�._-..��-�---�___.___�._.-•-----,---_- ._._ =� ��
..,_ � � , �� ��
�- _ � �� � � - _ � ���-
� � `
. �1 � Q w���
�' � O G V O
�Z � Uv� U
d� � � J�u� U�
J �
� � ��� �
'' � �'�.7L11
� — ' � �.�; ,�,� �,L�����i'x," f.�'
Q.#� ,���'dv �ha� "� "1.��i`f..:�.i)W ���j'�,����¢���� �cl � � :��!� 1P '� �(7 J �!Z ` .
�� � �u �zmWa
—� o ����u
� Z r — Q"�
�V � �3ar�,��'J'� �''�/`���,�b�c�
......._....,. _ . ....._....�.�__... -- � �•.� o,�'"�,._. � ` � �`--�7�L��...._._ I , ; ,_..._
§.... � �° ...... ._.._.E..w..�j�._:, � I
.......u_.....,,,.-, .,.._r,M_�...�..._..._......._...._..._ � :;� �X� t...�. �"c.a� � ; �
; ��, ,, �,- � ,
i ''`"�''��r�.,.� �� ; � , �c���
�� �,, � . � r
� � �
j 7
t
1
� • � " �S�y�i o�( � � .�—e... .. }
f
� � `�7��'`����'7�re'�, � j {
�" ,�'� �,� 7'� ± j �
� /�'li;fr,o r j p ,t$a%�j ?��� F ( f
,�• c� � e ' ��' � !
. ' i �,�i,
s�jj+� "(C��t'�ii�'iY+��'�11 � ` - e L�"',V V
_ �-� o�� a
'J•���� � 4
�'<. ,�;.�e f��,j�r�; s
._ '�-' ,
`�,.,�• — --------_. ._..��,__...__.�...:.�'' "� �t.t,��. � ;
•... �.---,--------- ., � `�--` � i i
�-,,.,�,.��:..._.._._..,.,...�_.._._ .��r �` � � I
�� „ f�-',,,,,..�•�, .� .. 4
.�.�,�, � �-.�..�`�. �. ��7;� 2/ �---` ; i
'�� r�l''��J�l� �'�h�� ~�� ��1 �f � ! t i �
!d d� ( i
t � ;�� �j��' _ � { �.
s��.�`f��� ����������- � �� y � � j
7J���"7t- i'�
�;` d ��''U t
���i @d��C,� �
i
� }
�
^ . v..._�..�� �� �._.._.
•.�.„ - �.:�. �
-�..
-��.
�� �r J }a . I
M�.-�,r.^ jI
Cl�O�ZG��lyI'�S
BUILI�ING PLAN REVIEW CONIMENTS
ContractarlHomeowner: ;� IQ,(�l� �C}�i�>�(�(�f (�!�
Date R.ecezved: ,� --v�,�-- j �
Site: �cS 1�O l"��% I�Itr!t1 ��y
Pertnit Type: �1ZJ�� (�l� ��
Approved w/no comments:❑ �pproved wltlie below eomments: � Denied w/the below comments: ❑
- ���U�� ��� t �r� ������ �_��,� .
. ��,
�� �J� � �� �r� ����f.�,l � � ���
�,
�,
�
,
�
�
` �is comment sheet sha11 be kept with the permit andlar plans. { ',
I� � � �
i
,I � � o?
alvin S "itzer Examiner I3ate Contractor and/oz Homeowner
' (Requireci when camments are present)
1
, __� .
�,°"°°° ,-:��r�.'.
��.
t�R11�F'1
G O`N $T R:U.C''i'-1Y��.-N
May 4, 2017
American House Senior Living Communities—Zephyrhills
38130 Pretty Pond Rd.
Zephyrhills,FL 33540
Attn: Mike Diaz
REVISED 5.4.17 -Proposal for Equipment Storage Building
I'm pleased to provide a quote for a 12' x 20' storage building based upon the following construction
details.
1. Floor system will be 2 x 6 pt(pressure treated for ground contact) lumber set on 24"
� centers with a deck of 3/4"pt plywood. The 2x6 joists will rest on concrete paver block
and the structure will be anchored using tie down anchors that screw into the ground.
2. The walls will be 2 x 4 x 8' studs placed 16" on center.
3. The roof will be 2 x 4 rafters on a 4/12 pitch spaced 24" on center with 1/2" osb
sheating, roof underlayment,ridge vent(for ventilation), and shingles in a color to blend
with the facility's current roof color. Roof overhang will be approximately 10". Fascia "
will be lx6 fascia with a vented soff'it using fiberglass screen as the vent.
4. The exterior walls of the building will have LP Smartside siding (8' on center grooved
siding) which comes primed ready for paint. 1"x 4"Miratec trim will be installed on
the corners of the building and as casing around the roll up door. The interior walls and
ceiling/roof will be exposed framing.
5. One 8' (width) x 7' (height) roll up door will be installed complete with side brush
sweeps and metal threshold.
6. One 12"x 12" louver vent will be installed in each gable end.
7. The owner will provide all caulking and painting of the storage building.
8. Contractor will furnish a drawing as required for permitting and will provide the
building permit.
I propose to provide all labor and material for the above improvements for the sum of$6,500.00.
Payment is to be paid in two payments: 30%down payment and balance of 70°/a when building permit
has been finalized. Work is to be completed within 3 weeks upon issuance of building permit.
Final ayment is due within 10 days of invoice.
P
11932 Duck Lake Canal Rd
Dade City,FL 33525
Email:ken�buildwithgriffin.com Ph:352-206-1841
�
Page 2, Proposal American House
Respectfully submitted,
Ken Griffin
Griffin Construction
Acce ce of P � posal for the Sum of$6,750.00.
�'�r d� American House, �� 4 � j � Date
11932 Duck Lake Canal Rd
Dade City,FL 33525
Email:ken@buildwithgriffin.com Ph:352-206-1841