HomeMy WebLinkAbout17-18614 CITY OF ZEPHYRHILLS
, 5335-8TH STREET
, _ (sis)�so-oo20 18614 �
�
_ . BUILDING PERMIT SINGLE FAMILY RESIDENTIAL � ��
- PERMIT INFORMATION LOCATION INFORMATION
Permit#:18614 Issued: 6/28/2017 Address: 36077 STABLE WILK AVE �' '
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. �� ;
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page: �
Cost: 242,075.36 Total Fees: 11,286.69 Subdivision: SILVERADO '
Amount Paid: 11,286.69 Date Paid: 6/28/2017 Parcel Number: 04-26-21-0070-00100-0300
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC I
Addr: 15550 LIGHTWAVE DR Address: 4600 W CYPRESS ST STE200 I
CLEARWATER, FL. 33760 TAMPA, FL 33607
Phone: (727)479-1740 Lic: Phone: 813-574-5700 i
Work Desc: CONSTRUCT SINGLE FAMILY 2,276 SQ FT
APPLICATION FEES
BUILDING FEE 1,015.33 ELECTRICAL FEE 206.33 PL MBING FEE 137.55
MECHANICAL FEE 96.29 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfd100% 4,828.00
SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
� ��
i �
✓ � �
�OC
�/
s , ��C��,
- Ins ections Re uired
FOOTER 2ND ROUGH PLUMB MIS INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY �
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC. I
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental I
entities such as water management, state agencies or federal agencies. �,
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for '
emprovements to your property. If you intend to obtain financing,consult with your lender or an attorney ,
before recording your notice of commencement." �
Cornplete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance '
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. ;
NO OCCUPANCY BEFORE C.O. I
i
-��
CONTRACTO S SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED ,
PROTECT CARD FROM WEATHER
� i �
I IIIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIII III��II IIII
�� • ' 20770991�7 �
� � Rept: 1873844 Rec: 35.50 I'� �
DS: 0.00 IT. O.OQ I �
06/23j2017 eRecording ;
I
Tlus Instrument Was Prepared �
By And Shonld Be Returned To: PAULA S.O'NEIL,Ph.D.PASCO CLERK�COMPTROLLER,
06J23�2017 09:46 gI3 1 of 4 �
Lee E.Nelson,Esquire OR SK ���� PG ��� �
' Shutts&Bowen LLP � '�
, 4301 W.Boy Scout Blvd.,Suite 3a0 I ��
Tampa,Florida 33607 i ,
I� � �
� i I,
I � I
MEMORANDUM OF OPTION TO REPURCIiASE i I
� I I
i
TIiIS MEMORANDi7M OF OPTION TO REPURCHASE (the "Memorandum") is i
made and effective this Z Z day of �H e , 2017, by and between DUNE FL LAND I I
SUB, LLC, a Delaware limited liability company ("Seller") and LENN.AR HOMES, LLC, a I
Florida limited liability company("Purchaser"). � I
RECITALS:
WHEREAS, Seller and Purchaser have heretofore entered into a Lot Purchase and Sale
Agreement, with an effective date of July 7, 2015, as amended (collectively, the "Agreement"),
for the purchase and sale of property located in Pasco County, Florida, as more particularly
described therein,and �
j
WHEREA5, Pursuant to�the Agreement, Purchaser has concurrently herewith, closed its � I�
purchase of the following: �I
See Exhibit "A" attached hereto (each individually the "Lot" or collectively the ''
«��,�� ,
�
� ��
WHEREAS, Purchaser's purchase of and closing of the Lots is with the intention and for '
the purpose of Purchaser's consfruction thereon of a single family home,and
WHEREAS, pursuant to Paragraph 21 of the Agreement, and pursuant to the terms and �
conditions set forth in this Memorandum, Puichaser has given and granted to Seller the option to � �
repurchase the Lot(s) in the event that Purchaser desires to sell such Lot(s) pri.or to its �
construction of a residence thereon, or prior to entering into a written contract to conshuct a �
. residence on such Lot(s)for its intended purchaser, I
�
NOW THEREFORE,for and in consideration of the premises hereo�the mutual covenants �
herein contained and for other good and valuable considerations,the receipt and sufficiency of all of !
which are hereby acknowledged,Seller and Purchaser do hereby covenant and agree as follows:
' Section 1. Recitals. The above recitals are true and correct and constitute part of tlus �� ,
li Memorandum. I
'I �'� .�
OR BK 956� PG ��� I
1 '
4 of 4
�
, � I
I
i
EXHIBIT"A"
I
Lots 30 and 31;-Block 1, SII;UERADO�RANCH SUBDNISION PHASES 2;3 & 4;_according ;
to the plat tliereof as recorded.in Plat Book 73, Page 59 et seq., of the Public Records of Pasco
County,Florida. ,
i
AND �
Lot.�l i,_Block 2;,SILVEREIDO`RANCH SUBDIVISION..'PHASES=2; 3 & 4; according:to�-the � �
plat"thereof as-recorded iri Plat Book 73,_Page 59 et seq.,o£the Public Records of Pasco County; � �
Florida: '' � � - � - � - � .
i
AND
Lots 7 and 8, Block 4, SILVERADO RANCH SUBDIVISION PHASES 2, 3 &4, according to �I
the plat thereof as recorded in Plat Book 73, Page 59 et seq., of fhe Public Records of Pasco �
County,Florida.
TPADOCS 21618733128053.0162 ,
' I
I
I
�
�I
�
I i
I
I
�
� � - -
i
, i
'
OR BK ���� PG ��� I
+ � 2 ot 4 �'
, ' II
Section 2. Option. Purchaser does hereby ratify and confirm those provisions of I
Paragraph 21 of the Agreement pursuant to which Purchaser has granted to Seller, and Purchaser ,
does hereby grant to Seller, the option to repurchase any Lot�in the event that Purchaser desires �
to sell such Lot (a)prior to its construction of a residence thereon, or(b)prior to entering into a . �,
written contract to construct a residence on such Lot for its intended purchaser(the "Third Party �
Buyer"). ,
Section 3. Term of Option. Purchaser and Seller agree that the option rights described in
Section 2 of this Memorandum shall immediately terminate as to each Lot without the necessity
of recording a termination hereof in the Public Records of Pasco County, Florida upon the '
issuance of building pertnit from Pasco County, Florida for the residence on such Lot (the �
"Termination Date"). For the avoidance of doubt, the Ternunation Date shall be established as a i
matter of public record upon Purchaser's conveyance by deed of the Lot to a third party buyer.
. i
Section 4. Bindin�ect. The provisions of this Memorandum and Paragraph 21 of the �
Agreement shall run with title to each Lot, as the case may be, and shall hereafter be binding �
upon Purchaser and its successor and assigns until the Termination Date.
' IN WITNESS WHEREOF, the parties hereto have caused this Memorandum of Option
to Repurehase to be executed as of the date first written above.
WITNESSES: ASSIGNOR: '�
DiJNE FL LAND I SUB,LLC, a Delaware '
limited liability company '
��� � � j
By: �
Print Name ohn M.Ryan,Manager �
I
�
Print Name �
�
STATE OF FLORIDA ) �
) ss.. �
COUNTY OF HILLSBOROUGH ) I
�I
The foregoing instrument was acknowledged before me this�day of �
2017, by John M. Ryan, as Manager of DUNE FL L�AYH I SUB, LLC, a elaware limited
, liability company on behalf of the company, who �1s personally known to me or (� has
produce or identificarion. -
. i
�
I
Not y Public �
My Commission Expires: y'��� ,
• .��.....--•�-��+..`-'
r�.•���y�' KELIEYREMMEL
�4����
,: MY COMMISSION�GG 0731T!
cr' i I
'sw,.f .g EXPIRES:Mey 31,2021
�'.�go� �P.• 8ordedThiuNota+YP�CUr�d� i
.,�f.t•'' . I
�
, �
i
, �
�
�' , �
OR BK ���� �'� ��� � (
3 of 4 �,
. �
� . �
i �
,
i
1
'WI7']1IE$SE�: ASSIGNEE: � ,
I
�
LENNAR HOMES, C, a Florida limited '
liability comp !
I
B �
Pr�nt Name N !
.
. ..
Its: t ;
L,��..1.��J�..����..�...��+�� �
Print Narne�,,;��.VC�t v►C(..� '
�
. {
(
STATE OF�C l���O�__}
}ss.: �
COUNTY OF�� �
The foregoing instrument was acknowledged efore me this�day of , '
2017, by � L.• as �L4�.. {�� �i � ^1- af LEI�NAR
HOMES, LLC, a Florida limited lia�ility campany, on behalf of the company, who is �''I
personally known to me ar �}has produced far
identification.
lL��►��'���.�����.�-�� . i
Notary Public �
�
� ��� I
i
My Commissian Expires:�� i
�tr. CARDlhil�t�
�60TI�1Y PU�LtC !
,. St'Ai'��F f1,t3R10A ,
. '.' . � Carnn#FF0992A8
Expires 3/8/2Q1� �
'
�
�
� � PASCO COUNTY, F '
LORIDA
Jl . Permit No. �` �
Date Permitted –�
Builder Name/Owner Name �n��P�.B Control# �
County Parcel No. Q�1�Z/_bj17p p�j/� �d(> SubDiv; S, �ye/z�d I
Address/Location ��Q�� ���,e �1,,C,��`��i C�"f�"�.
r
Classification/Type of Use �` IP�� ��,����
� ,
TRANSPORTATION IMPACT FE • Rate: '
Sq.Ft Unit: 2�_ i
Exempt � Yes � No How Determined
Impact Fee Amount $. �, �32-• Zone No. � i
— .�_ TAZ: �
�_ �
SCHOOL IMPACT FEE I
Account (056) Single-Family Detached House Amount $ ��� 7�p� z,�j
(057) Mobile Home ,
(058) Other Residential !
123) Collection Fee ;
Exempt [� Yes � No How Determined �
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account � Recreation Credit �
Recreation Total i
Zone TOTAL AMOUNT $ 7(Q �'. ��, ,
Exempt � Yes [] No How Determined
LIBRARY FEE
Land Account Land Credit 'i
Land Total ,
Facility Account __ Facility Credit I�
Facility Total
Exempt � Yes � No How Determined
� Total Amount '�/ _
RESOURCEFEE ERU
TOTALAMOUNT '�
i
i
Prepared By Checked By
�
�
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUN7S LISTED HAVE I
RECEIPTED FOR BY A CENT ALEP RMI I'IT NG OFFICE OF PASCO COUNTY I
� �
Acknowledgement below does not Imply acceptance of concurrence,but simply recelpt of a copy of this form,placing
the bu(Iding pertnit owner on notice of this assessment and the conditions of payment for same. '
DATE
RECEIVED BY
RECEIPT NO. __ pATE ___ gY
• . .. i
O_ I
• • :�� �. .
:'���
� • S:` °.�j�y-C�'�'. ��.'./�1 I
. -.� - �u-e"+i�:- ej: �
Zs
,Ci -�..�,r„r�1 � I
:�- �
-�`'�`_-,. .. : �
' City of Zephyrhills �
BUILDING PLAN REVIEW COMMENTS �
� I
Contractor/Homeowner: �/���Y� �
�L����
Date Received: �l �l / I
Site: cJ�d � `JtGC�I� �r/�!`�
�
Permit Type: V( /L � � ��'1�✓J'1N ����`�`�� I
i
Approved w/no comments:❑ Approved w/the below comments: � Denied w/the below comments: ❑
i
i
_ Q�G� ��/� �
I
I
I
-__- i
I
Tl�is comment sheet shall be ke " w'th the pernut and/or plans. �
- ,
�
,� � /`. � �'��
Kalvin Swi er—Plans Ex iner Date Contractg and/or Homeowner '
(Required when comments aze present)
� !
i
I
�
, • r ' IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII�IIIII��IIIIIIIIIIIII
17101186
Rcpt:1874825 Rec: 10.00 -
DS: 0.00 IT: 0.00 '
06/27/2017 K. K. , Dpty Clerk '
f
PRULR S 0'NEIL,Ph D PRSCO CLERK & COh1PTROLLER ,
060R7BK 1C�5��m PG ���J� �
- Permit No. Parcel ID No 04-26-21-0070-00100-0300
NOTICE OF COMMENCEMENT
State oi Florida County of Pasco �
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,
the following information is provided in this Notice of Commencement: -
1 . Description of Property� Legal SILVERADO RANCH SUBDIVISION PHASES 2.3,&4 PB 73 PG 59 BLQCK 01 LOl'30. , '
st�eetAad�es5: 36077 Stable Wilk Avenue Zephryhills FL 33541 -
2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure!Fence �
3 Owner Information: Lennar Homes, LLC
, Name
4600 W Cypress St. Ste 200 Tampa FL. 33607
Address City State
i Interest in Property�
� Name of Fee Simple Titleholder N�A _
(If other than owner) , �
Address City State
a. contractor• Lennar Homes, LLC
Name
4600 W Cvpress St, Ste 200 Tampa FL, 33607
� Address City State �
Contractor's Telephone No.. 813.574.5700
5. Surety ... N/P1 � �
� Name
Address City State �
Amount of Bond: $ Telephone No.. 1
6. �ender N/A ' ,
Name
Address City State �
Lender's Telephone No �.
�
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by �
Section 713.13(1)(a)(7),Florida Statutes:
" Lennar Homes. LLC �
Name
4600 W Cypress St, Ste 200 Tampa FL, 33607
� Address City State
Telephone Number of Designated Person: 813.574 5700 ,
B. In addition to himself,the owner designates N/A of
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner:
- 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: �
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT
STATE OF FLORIDA �� �
COUNTY OF PINELLAS �
Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager
. Vice President
Signatory's Title/Office
The foregoing instrument was acknowledged before me this 6 day of Ma�ch �U!7 ,by
Steve Smith as VICe Pfesideflt (type of a e.g.;o�cer,trustee,attorney in fact)for
Lennar Homes, LLC (name of p a f of whom instrument was executed)
Personally Known�OR Produced Identification❑ Notary Signat
Type of Identification Produced Name(Print) Elissa.Holleran
Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in
it are true to the best of my knowledge and belief. -
L��� ' � ELI55AA1,HOLI.ERAN Signature�l Person Signing Above
;.�-Gmmb�Ibn�FF88583T .
' Fx�lres June B,2020
wpdata/bcs/bcs form: ,�0��•�'��.�nddThmTroyFolnlMunncel00a15-701p
��������o�.
� �• a .
��e ,.� °�
�. �t,5;�. ..¢��t � .� - -- —
�� `
STAT�OF FLOR9DA,�COU6�TY��PASCO � � �i� � �a�s ,���; �
THIS IS TO CERTIFY THAT THE FOREGOING IS A � �J�-.� � '
TRUE/�ND CORRECT COPY OF THE DOCUMENT �� ��`��'�� � ��
ON FILE OR OF PUBLIC RECORD IN THIS OFFICE � '°�":� °, . � ���
WITNESS�MY HAP�U AND OF{�ICi;�LSEALTHIS � ��'�����
�_�DAY OF � 2��
PAULA S.O'NEIL, C RK&COMPTROLLEF�
SY ���.� �DEPUTY CLERK
• $1`3-7$Q-ff02p City af Zephyrhi()s Permit Application Fax-813-780-Op21
Building Department �
' ._ �
Date Received Phone Contact for Permittin 813 363 __ 2891
-`_[_� . ....
Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.570p
Owner's Add�ess 46aa W.Gypress St,Ste.204,Tampa,FL 33607 Owner Prione Number �_ —� �
Fee Simple T�tleholder Elame N�A � pwner Phone Number �� �
Fee Simpte Titlehoider Address N1A
JOBADDRESS 3607? Stable WilkAvenue LQT# 0300
SUBDIVlSION Silverado Ranch Subdivisipn Ph 2,3,&4 PARG��io# 04-26-21-0070-Q0100-0300
` (087AINED FROM PROPERTY TRX NdTiCS}
WORK PROPOSED II�/ �� NEW CON57R 8 ADD/ALT � SIGN � Q DEMC7LISH
� It�lS7ALL REPAIR
PROPOSED USE � SFR Q COMM 0 OTHER
TYPE OF GQNSTRllCTIQN � BLOCK Q FRAME � STEEL 0
DESCRIPTION OF WORK Single Family Residence/ e - nce
ulx sF 2276� 1817 1 Sto . �
BUILDING SIZE SQ FOOTAGE HEIGHT rY
✓ BUILDING $ '/ ,� 1�'`a VALUATION OF TOTAL CONSTRUCTION �
�.� �r�
��/ �ELECTRICAL r> � � PROGRESS ENERGY Q W.R.E.C. i
l- ' L AMP SERVICE
�PLUMBtNG ���
�
'i�/ �N3ECHANIGAL �� VALUATION OF SViEGHANICAL INSTALLATIQN f j p�
, . � �i�' ' � t
/� r Y
�GAS � RQOFtt�G Q SPEGIALTY � aTHER
FINISHED FLfJOR ELEVATIONS CT� FLOOD ZONE AREA �YES �O
u
•�--1-1-1-�--F-�-�--�--4-1-�1-F-�-f--�-F-F�-�F-1-�4��-1-1--F-1-�F-�4-1-�E-F-E-4a--�•-�-�-a--F-1-�-F-�--�•i-�--�-i-i-�--E-�-�t--1--E-;-�-�-1F-1-
BUiLD6R C4MFANY
Lennar Homes,LLC (
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N !
Address
4600 W.Cypress St.Ste.200,Tampa,FL 33607 Lieense# GGGl5i8166 � i
ELECTRICIAN COMPANY Edmanson E4ectric, �CIC.
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 1034 Skipper Raad,T�mpa, FL 33633 �icense# EC13005448 —�
PLUM8EE2 COMPANY S�Yanet Plumbing, Heating &AC, Inc
SIGNATURE REGtSTERED Y I N FEE CURREN Y I N
Address P.O. Box 5308, Bayonet, Fl.3467Q-530$ License# �FC042998 �� '
MECHAHtCAt. COMPAlVY Bayonet Plumbing, Heating &AC, Inc
StGNATURE REGSSTERED Y J N FEE CURREN Y I PE
Address P.O.Box 5308, Bayottet, FL 346 4-530$ �.icense# CAC058062 ��
OTHER COMPANY
SE�NATURE REGISTERED Y J 1d FEE CllRREN Y I(�
Address 4211 Shoal Line Blvd, Spring Hill, FL 34607 License# CCC057991 —�
i11IIllilit ! lIIIIII [ ltf111111IIItliI11I [ i111I1t1IIt / ill [ tllt [ [ I1111 �
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Farms;R-O-W Permit for new construction,
Minimum ten(14}working days after submittai date. Required onsite,Ganstruction Plans,Stormwater Plans w!Silt Fence installed,
Sanitary Facilities&1 dumpster,Site Work Permit for subdivisionstlarge projecfs i
COMMERCIAL Attach(2)complete sets of Buiiding Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit far new construction.
Minimum ten{10)working days after submittai date. Required ansite,Constructian Pians,Stormwater Plans w!Sift Fence insta!led,
Sanitary Facilities&1 dumpster Site Work Permif for aII new projects.Ai!commereial requireme�ts must meet comptiance
SIGN PERMIT Attach(2)sets of Engineered Plans.
*"*PROPERTY SURVEY required for a(i NEW cons#rucfio�.
a..4�f..�-t.�-1�1..1-.E..I..I-E-�-i-I--F.�1-i..i..i-i..��.i-�-�i..�I-1..i-i-F./-I..i-�i-l..ti.a-.1.��{••i•i-1-�I-M.t-i..4.1.i-I..i�i-L.i..i..1.i..ti.i.i-1�
Direetions:
Fiii out application comp(etety
Owner&Contractor sign back af appiication,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
** Agent{for the contractor)ar Pawer of Affomey{for the ow�er}wauid be someone with notarized tetter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingies Sewers Service Upgrades A!C Fences(PIoUSurveylFootage)
Driveways-Not over Counter if an public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restriction's"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES� If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEfd LAW(Chapter 713, Florida Statutes, as amended) If valuation of work is$2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's �
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT. I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/VVastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill.
- Use of fill is not allowed in Flood Zone"V" unless expressly permitted
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR N ICE OF COMMENCEMENT.
FLORIDA JURAT(F.S.117.03)
OWNER OR AGENT CONTRACTOR
Subscribed and sworn to(or affrmed)before me th� Subscribed and sworn to( r affirmed)before me this
un-Hpr-i i by paul Sweeney 06-Apr-17 by Paul S eeney
Who is/are personally known to me or Who is/are personally known to me or -
as identification. s identification.
Notary Public Notary Public
Commission No. FF98537 Commission No. rF98537
Elissa M.I Iolleran Elissa M.Holleran
Name of Notarv tvped,printed or stamped Name of Notary typed,printed or stamped
p -�1 ' ... _._..._....
,r" ', ��19�I�,91QI��1
'' :� ��I�J4H,��I��'f
ClRdtr`'�lbAiM�(�8l4���' � V���R�n`ki!68,����'!�d@�7
ti� �M$t�lul�t��,�d�d
1 ���56��,�ut���d�"�k�� � .�,:- �2n�1't:�Y.ro��dt�iy+ilif�K4,515��FI1
,...f ISafi�i7►r���rjlFad�E,,cntbtti+Wl1N?�U "
I
I
� �I
, � 36077 Stable Wilks Ave
- ;
` i
. o umn
�
� SQ. FEET PRICE ',
UNDER ROOF: 2,276 $ 106.36 i
I
OTHER: - $ -
VALUATION $ 242,075.36
FEE SHEET $ 917.00
� ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,015.34 �
ELECTRICAL: $ 206.33
PLUMBING: $ 137.55
MECHANICAL: $ 96.29
SUB-TOTAL $ 1,455.50
TOTAL $ 1,455.50
SEWER: i
WATER:
IRRIGATION: $ - I
TOTAL: $ - �
WATER METER: I
IRRIGATION METER I
FIRE DEPARTMENT FEES
` PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ - I I
� i
PUBLIC SAFETY IMPACT FEES I� I
POLICE $ 254.00 � �
FIRE $ 273.00 �
5% $ 26.35
TOTAL: $ 553.35 !
I
SUB-TOTAL $ 2,008.85 i
PARK IMPACT FEES $ 769.56 I
SIF'S: $ 4,828.00 I,
100.0% $ 4,828.00
1.0% $ 48.28 ,
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00
99% $ 3,595.68 �
1% $ 36.32
TOTAL: $ 11,286.69
; _ I
i
Single Family Dwelling
Plan Review Comments
1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan.
2. Lots shall be graded to comply with R401.3 of the F.B.C.
3. Compaction test required if 24" or more of fill dirt is brought in at any one place. ' I
4. Tie in survey required before pouring concrete. �
' S. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have '
expansion material.
6. All setbacks shall be met.
7. All property markers shall be uncovered and marked at time of first inspection.
' 8. All A.D.A. requirements shall be met. ,
9. No electric, plumbing, mechanical, or framing shall be covered without an inspection and ';
approval first. �
10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).
11. Appliances shall not be installed in a location where subject to mechanical damage unless ; '
protected by approved barriers. M303.4 of the F.B.0
12. Water heaters shall comply with section P607.3 of the F.B.C. �
13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 ;
14. Return air in all bedrooms. F.B.C. M1620.4 , li
15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. ' '
' 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. I
17. All means of egress are to be in accordance with R311 of the F.B.C. '
18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. ;
19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. '
20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating j
' or appliances or an attached garage. They shall be installed in accordance with the F.B.C. �
21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all ,
underground plumbing and electric. �
22. A112008 N.E.C. Codes will be enforced. '
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 �
22. In accordance with the Land Development Code, lots shall be sodded before final at least 10 �
feet around the structure. �
F.F.E.-Finished Floor Elevation
F.B.C- Florida Building Code 5�'Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008)
' -J- ^O� ( (�.� `�- •�A•- ^ � r _ -+" , -'r� er Qc�, --r v - �� aP yuJRt. , �
, ��f��- � �!1 y ,O� �^ 1�� �O 1. ^�•J � l JI �A� � O1E • _ (�. T�J� r. �. - s '�� \N = , �
O��' u �p L �. O1 �1� ,-�` �..0`' 'S . '� Q :��� - --- - G� (��'`1.,�- ��� ps -'- f �� ,. ',` ,
n G r� n � � �
G�n� , O� _�OL ''� . Tn�- aCb' ��' f �� ^r V �Jv' `T'��� ✓` �� - I ` � :�.�
1 J r� V �� \
'l�1 , 1� ��C '_' �, '�J� 1 ��` T� � �� ��� ��� � +
�u=o ,�p� ' . ;�' .a . '� .-` C�.-_�b ' ir ,r�\ � �� --
-r-• o .� - _y ., - ' �
� � �Q� � n .� -- � � 1 � e,r \. �R, ''\ ---Q`�
, _ . Q
�• � i
� Dc _�n , "�. .t _ O, �
� v O 1•
. � . &
.C., 5 � 5 b . `L � �,..�, '1 -� � . , �. � '�
� -i-- , •�
.L � , F .. ti0 ,
1 . . �� o . . _
g . ti
t� � f� - (� - r
7 � O� .
�J� r� �v �O�� �1�� ,L1� ��� 11�' :J� �=J� O����/` �` - -p��.. ' ' ' ' ` - ` v• �` r01c 1{� • �� �q:``.
, _,'� �v ` � ` � � J � '�j`" ' , °�2�"'' �1 �1 . ._ ` ,_ � � ', . ��� �`\` -c�-��9 , '�"'� _
O o '�--�•--.
, . • , o�-0.o.a•a'o'd"• ;..�} -rp• '! � �` - - �� -i- �j aJ - �'`�� y°��'� '
��,7G �c� • Q o.�.o�a .�� _g, ` � ,�o, _ Q . °��s.� ,
� O�� �o, o•o�°�a. _ - � 1 �. � �' ,l '\`��- °-c�.�ss-a-a
_h1 y� � �1 �p� ��, -.�o.o�o�O�7� , c o.�� �d 5 � g� � _ � • '� g� `� -
'�� y1�x•� �p�` __,�0� �ao0•p.p�\� .0 _� ,� ��� 0 . ° ' �-c'-- _ �. O ,�937 , T� �"- -�9�` 6 �,� �,,./
. ' � T ^�,.o.o•a;o'°'°n � ' - �� �C'� � ' _ -��` ^ �"5 ,� .a� '� ``�� �
. �� ��!- � 5 � � �. 0 O� _ - � i o9�sa �� � `
O O ��t c�
a_ b:• � , -� Q C�•
90r
- O �4. •
�1 , 'o� ��-
J-� � o � �
�� -n- � •'� . FF=t82.1 ' LO �0 'Cj .
� , �
� �, •o °� _ LOT 31 - r , _ � �
�r _
_ g
. � T 2 =99.70
. Co FF ,
. 4
T -
�
.� - . V
� � 99.9 • � �
- q�' -
P
. o LOT 32 n -i a � �
<S
P D 00.
� O � FF=102.8 - PAD-99.2 LOT,-,Z� ' .D� 30A �� �
- - TYFE B' - G • - � �
P�• � (^�+ AD-101.4 _99.70 , .
TYPE B FF _
� PE��B �
TY 4�J.0
P O
LOT 3 , -
- C�•
` . "�' TYP E A B - . -� c
� ,
T 7 - • � -
_ /
LO 2
_ .
_ �E B , C�,
� , FF-104.fl PA(6 10Z1 � . �- -
i _ 1 . '� � 'ie
�. PAD 99.0 •
LOT 34 L 9 � ' � � �
\� 4 FF=1Q5_ AD=103�,3 ' �S'PE A , oj� �� 7YPE B =49-�D, - � D� cj.� '�-.
\` �� LOT 35 TYPE A �� .__. '�__---- � ---- - ____ ro La��.25 -�;� w' _ a ,� ��
�� ` FF=1b,6.b A0=104.8 '�• _�- -r �SEM� - -_ ____ ` ' � PA9='9�9 ,a� � ;� ' 'S zi
� �� � LOT '36 �', TYPF A � _-' 0' �� - � 98 34 _ .c� � TYFE B� �'S�,� �' - • -
� �-_ , �p
O ��'1' PA0=1Q�_ �OJ �, r'1� '1 �, � rL"� '� � Cc"` � i1 98.1B� ,, ` ��'�F, 6.7 �� �� � ;�'�,
, ` TYPE�Y+� ,�p�' v 'N� r' , ^• ^G .�•. , v `r'• � '�A '� _
�c� � .- ,_ _�� _ _,�. � e � a �� �3 '•, :.,�
. ` -' ' � :�� o 'i�- ; _ rs �1�• • �. ' �,° '`�ro• a, . zr
` c,� `�R°� .o� �`� ��� . ,�y �.
\� \� -���''' o� `� '`_ •\ �` � 0 � Q � FF=99. �,5 �' ��
. �\ o- ^ `o �,�� i _ � ^5'a LQT �; . ,o, _-
1� , �, �- � , � ', PAD�8.9 � -
� ' J C >> �1� �7��, -`�� -- �'�� r r _ ----- - �.___ _ _ �y p �� TYPE 8 �P 8 � _ 1U'
ik � ,y'. � �T - ' •� \ 1 � _�' - � p � � �i , -�� �,l 6 .�� r� - , �
�V `��, ^ �. � � , ._ ,, �' ,� ' �' ��g . Q �;p;' ' �`� ' - - • �
�` 10;�c�' �� � FF=101_70 ��FF=100.90 100.20 � p�� .p4 gg. aGj- '��
�� � .
'�p� �`Lg FF=10 ;� LOT 11 PADTiDO_ LOT 9 `� i� + , �� i .n`�o �� o
' =� LQ�. 1 2 AD=101•0 PAD=99.5 b . . .
� �� � �� ' FF=1a3.6 PA0=T0,1_9 � TYPE � TYPE A E A F=100_20 91 -� b�'1 ' � �QGj• '' � 8:
�� , �� L0� 13 TYPE A V�� � LOT;8 + „•
PAD=99-5 � , • � 'a`=99.70 J ��z
\� ` FLOT 5 4 � '�'rPEQA g ���0 � � %_ O � �;A �r �G/ �� -��� LOT 25 - �� �
L . � FF-106.4 AD=10d.3 - ;.� 0� �.� � g 2 PAD=99_0 - �
G' „f,r
� � L�7' 15 TYPE A �. � -�'�' -!' °�g -�$' y � T�(�E B , �`:'� ,��
h b \ AD=10�J � , � �
-� J_ � :1 i ,. "�� �� � � .,� _ `oj�. i
���� � '• '�, ,� 71'�bca �. �;�'� '� �3_5 _6 0 �� ' � 1- ��� � ��T -- � . Dc �� ti
�-L p,�`1'�_ 6 ` � _.1= �1 7 �x • r�� � � � � 4.�/ FF=1Q0_30� \ g. � i#- q �
� � ` � , � � � a- ���' LOT 24°�, `, �� ��� �
�� ro PAD=99.6 , � 6 Qp, 6 �. �,r
� �y.,y �; � p ` ', �` L�. �\ i\ �� TYPE 8 +�� c,. ,�: i �
� ` p � -��\ o "� LOT55 � FF=105.00 �'. �j -�� �� '� ,_ ie-r�- e'�`,Q
� '.=�� ��t\ �- 1`" o FF=1D6.2 1 LOT 6 - =104 0 � � +� �J! • J '' `,� �
:� � ��, •B � o . LOT 4 ,, PAD=105•0 '. PAD-104.3 LOT 7�'. i° � ` � ' ' �+ ��� -�
, � S , - FF=107_ . PAD=1D5.5 ,Q?(PE B � ' 11A _ i•..�
- p� �,� � �, LOT 3 TYPE 9 .��B PAD=1 �fi oo � -� a, U� FLOT 23 ~�� � �
, �� �: r� � �7 a, FF=t07.7 AD=106 �- � TYP �`.
�^, ��, C 6'� �(� � �• Q� LOT'2 TYPE B -.� i��� ' __ �O� �x � � -- 8 P �00.7 ,n�g '��
-+ FF1=k4T8.fl AD=107� " �`' � ` �.
�, `, 1° �'-� � , �OT 1 TYPE 8. ? ----� _�Q�_ �� ,� 1 � � =� ,, \'��c��,�
' o, � l� Ph�=107.3 • �� '�_�~ O� --_ ' �� � A'� , . ,� �
� ,� � � fiYPE B _ �� -' 1 �" . � 1 1 :� ��
1 ,�0 1 � . . r ��1 - � �� .` �� �1.02.30 . �._ :�b °�
� cn5£�EN .'� 'J� n � �\ n 4]nT �� m��� 99• Ev�1`.
i
PL'OT PLAIV SKETCH ONLY SEC. 04 , TWP. 26 S, RNG. 21 E. .
LOT 30, BLOCK 1 NOT A._BOUNDARY SURVEY BEARING BASIS: '
SILVEf2AD0 RANCH SUBDIVISION NORTH BOUNDARY OF SE� OF 05-26-27 BEJNG N 89'25'01" E
PHASES 2, 3 & 4
PASCO COUNTY FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT
� • � MAY BE DISCLOSED BY A FULL AND ACCURATE
PRELIMINARY DRAWING: ON LOT AREA CALCUI..ATIONS nT�-E SEARCH. ALSO SUBJECT TO SETBACKS,
EASEMENTS AND RESTRIC110NS OF RECORD.
THIS PLAN IS FOR PERMI'IZING PURPOSES LOT = 6392.97 SQ. Ff.
ONLY, NOT FOR CONSTRUCTION. VERIFY IJVING AREA = . 18,38 SQ. FT. rai UNDERGROUND FOOTER, STEM WALI, AND
ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY = 32 SQ. FT. �� UNDERGROUND UTILITIES ARE NOT LOCATED OR
GARAGE = 406 SQ. FT. SHOWN.
LEGEND: COVERED LANAI =_f1,A SQ. FT.
.1-�= PROPOSED DRAINAGE FLOW PAT10 , = 23 $Q, �, w DO NOT SCALE THIS PRINT. DIMENSIONS AND
(00.00) = PROPOSED GRADE CONC. DRIVE = 339 SQ. FT. ¢ NOTES TAKE PREFERENCE.
E-00.00 = EXISTING GRADE A/C & CONC PAD =�8 SQ. FT. � DESCRIPiION NOT CONTAINING PLAT BOOK AND
PRIVATE SIDEWALK = 72 SQ. FT. PAGE INDICATES THAT PLAT IS IN
IMPERVIOUS = 43 �
NOTIES: - 2�28 SQ �. PRELIMINARY STAGE AND IS SUBJECT TO
LOT GRADING TYPE = B 50D = 3665 SQ. FT. CHANGE AND/OR REVISION.
PROPOSED PAD ELEVAl10N = 99.9' CERTAIN DATA SHOWN HEREON BASED ON
FRONT SETBACK = 20' or 22' OFF LOT AREA CALCULATIONS ENGINEERING PLANS PROVIDED BY CLIENT.
SIDE SETHACK = 7.5' RIGHT OF WAY = 947.72 SQ. FT.
REAR SETBACK = 15' DRIVE APRON = 233 gq, F'�', STRUC7URE 11ES SHOWN HEREON DENOTES
PUBLJC SIOEWALK = 266 gQ, �, MEASUREMENT FROM FORM BOARDS/FOUNDAl10N
SOD =�� SQ. FT_ TO PROPERTY LINE.
TOTALS * = 10' Ul1LITY EASEMENT ,
AREA = 7340.69 SQ, FT, i
DRIVEWAY = 572 SQ. Fi.
SIDEWALK = 338 SQ. FT.
• SOD = 4114 SQ. FT.
I
TRACT H ;
DRAINAGE AREA
�99��J 5 89°03'02'� E 62.27' �9�^�, ��
—. _�
� �� �� ,
-� �. � �
•o M�
�M
� •� •
:�AI� Pano �
�i o:it'' ssa�-
0 0
0 0
ao'–o^
�`�990, PROPoseo �ti��
LOT 31 J� PLAN L°�9•
7791 � LOT 29
BLOCK 1 � �� ELEV "B" � BLOCK 1
_ ou°i, GARAGE
oz RlGHT �
- LOT 30 �
N 6LOCK 1 7.83' �"
o .... O i
Z � �
7.83'
..3- j. . ��
� n,:: .•16.00'.._ �: .�
-vI.N �
0 p.
� �ryN_V._��� _ :M �
Q � . •0I N: :N�� i
� 99? y. ' * � 6R', �
co `?J ' L90
op��.: - . °C89`c.; - � . - ..�
� �PC(P)� - _o I
rn o ` � o
N . O" 'p
M �
� DESCRIPYI0�11: .
� LOT 30, BLOCK 1, MAP � - -__
J oR PLAT ENTITLED STABLE WILK AVENUE PROF90SED:
m "SILVERADO RANCH • (�o'R/w) (rnacr �.) LOWEST FLOOR ELEVA710NS:
, SUBDIVISION PHASES 2, 3 LIVING AREA: 100.60'
M & 4", AS RECORDED IN GARAGE AREA: �
= PLAT BOOK 73, PF�GES 59 ELEVATIONS REFERENCED TO '
THROUGH 65, OF THE NORTH AMERICAN VERTICAL
al CURVE RADIUS ARC CHORD BEARING DELTA �
= PUBLIC RECORDS OF co sss.od iss.zs• iss.as� N erzs•is^ E 14'19�so�• DATUM OF 1988. MEAN SEA �
� PASCO COUNTY, FLORIDA. cae 665.00' 53.37' 53.36' N 89'03'02'� W 043555" LEVEL= OO,�� FT. �
� APPARENT FLaOD HAZARD ZONE: "X" COMMUNITY PANEL N0. 120230 0455 D EFFECTIVE DATE: 09/30/1992
0
0
� EGEND:
> (C)= CALCULATED DATA, (D)= DEED pATA, (M)= MEASURED DATA, (P)= PLAT DATA, g= CENTERUNE, A/C= AIR CONDI110NER, 8/C= BACK OF CURB, C/S= I
� CONCRE7E SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM�T= EASEMENT,
/ F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
� PIPE, LFE= LOWEST FLOOR ELEVAl10N, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, P6= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
Q REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL &DISK, TBM= TEMPORARY BENCHMARK,
� U P= U1ILITY POLE, W F= WOOD FENCE, R = RADIAL
a Drawn By. S uare Feet: 639^c.97 t
� JOHN R.B�ACH&ASSOCIATES,INC. SMS q LENNAR HOMES
w � SURVEYORS AND MAPPERS y,
� 911 WEST ST. PETERSBURG DRIVE Checked 8 .
in ONE OLDSMAR, FLORIDA 34677 JRB , _
y WAY (813) 854-1276 FAX (813) 855-8370 Scale: '
� ���_30' WL `� �
0
; NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 3 29 17 ACS � Z ��
'v THE ORIGINAL RAISED SEAL OF A FLORIDA N BEACH DA7E
� LICENSED SURVEYOR AND MAPPER FLORIDA G. LAND SURVEYOR No. 2984 LB#4493
/ Revisions; ,
�
Y- �
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method '
Project Name: 1791 sf ADS Builder Name: Lennar Homes
screet: 36077 Stable Wilk Avenue Permit Office: Cl�of Zephyrhills
City,State,Zip. ,FL, Permit Number:� �o(
Owner• Lennar Homes Jurisdiction: 611600 � �
Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area �
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 1241.30 ft'
I
b.Frame-Wood,Adjacent R=11.0 331.33 ft2
3. Number of units, if multiple family 1 c.N/A �
R= ft ,
4 Number of Bedrooms 4 d.N/A R= ft'
5. Is this a worst case? Yes �0.Ceiling Types (1817.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 1533.00 ftZ
6. Conditioned floor area above grade(ftZ) 1817 b.Cathedral/Single Assembly(Vented) R=30.0 284 00 ftZ
z
Conditioned floor area below grade(ftZ) 0 11 cDucts R R ft2 �
7 Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 220
a. U-Factor Dbl,U=0.54 87.00 ftZ
SHGC: SHGC=0.31 '
b. U-Factor Dbl,U=�.56 33.33 ftZ �2•Cooling systems kBtu/hr E�ciency
SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00
c. U-Factor Dbl,U=0.56 23.00 ft'
SI1GC: SHGC=0.28 13.Heating systems kBtu/hr E�ciency ,
d. U-Factor N/A ftZ a.Electric Heat Pump 26.4 HSPF:9.00 �
SHGC: � - I
�
Area Weighted Average Overhang Depth: 1.233 ft. ,
Area Weighted Average SHGC: 0.308 14 Hot water systems �
8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF•0.950
a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features
b.N/A R= ft' None ,
c.N/A - R= ftZ 15.Credits Pstat
Glass/Floor Area: 0.079 Total Proposed Modified Loads: 54.39 pASS
Total Baseline Loads: 58.04 ,
I hereby certify that the plans and specifications covered by Review of the plans and ��'C�STIq?,�, I
this calculation are in compliance with the Florida Energy specifications covered by this �'�r , � "`,s'�., Q '
Code. calculation indicates com liance �ril°'' ``-'r.4`.� �
P �+s. �.q�:��.. .,=:�:.�,�, {.
/' with the Florida Energy Code. � tr�rrr^�'+��.,";�"'.��<<�,� �� �
PREPARED BY �aVe �����'c Before construction is completed ,w� � ' � �
:���, - � :p.
, DATE. this building will be inspected for �,ry �. �,.
l�: ..
compliance with Section 553.908 .*. � �' . ,�.
I hereby certify that this building,as designed, is in compliance Florida Statutes. � , ��
with the Florida Energy Code. � „1?;{�y�`��
OWNER/AGENT: BUILDING OFFICI L.
DATE: DATE. �-"�- t � '
I �
- Compliance requires certifcation by the air handler unit manufacturer that the air handler enclosure qualifies as i
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
fest report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confrming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house.
3/30/2017 8:19 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
� I
� �
, ' '
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION �
Florida Department of Business and Professional Regulation - Residential PerFormance Method
Project Name: 1791 sf ADS Builder Name: Lennar Homes
street: 36077 Stable Wilk Avenue Perm�t offce: City of Zephyrhills
City,State,Zip: ,FL, Permit Number
Owner• Lennar Homes Jurisdiction: 611600 ;
Design Location: FL,Tampa County�• Pasco(Florida Climate Zone 2) I
I
1. New construction or existing New(From Plans) 9. WaII�Types(1572.7 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 1241.30 ft' i
b.Frame-Wood,Adjacent R=11.0 331.33 ft2
3. Number of units,if multiple family 1 c.N/A R= ftZ
4 Number of Bedrooms 4 d.N/A R= ft�
5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area Z
a.Under Attic(Vented) \ R=30.0 1533.00 ft
6. Conditioned floor area above grade(ftZ) 1817 b.Cathedral/Single Assembly(Vented) R=30.0 284.00 ft�
Conditioned floor area below grade(ftz) 0 c.N/A R= ft' '
11.Ducts R ft'
7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 220
a. U-Factor Dbl,U=0.54� 87.00 ft'
SHGC: SHGC=0.31
b. U-Factor Dbl,U=�.56 33.33 ft2 12•Cooling systems kBtulhr Efficiency
SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00
c. U-Factor Dbl,U=0.56 23.00 ftZ
SHGC: SHGC=028 13.Heating systems kBtu/hr E�ciency
d. U-Factor N/A ftz a.Electric Heat Pump 26.4 HSPF:9.00
SHGC: �
Area Weighted Average Overhang Depth. 1.233 ft.
Area Weighted Average SHGC: 0.308 14 Hot water systems
a.Electric Cap:40 gallons
8. Floor Types (1817.0 sqft.) Insulation Area EF 0.950
a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ftZ b. Conservation features
b.N/A R= ft= None �
c.N/A R= ftZ 15.Credits Pstat ,
Total Proposed Modified Loads: 54.39
Glass/Floor Area: 0.079 PASS
Total Baseline Loads: 58.04
I
I hereby certify that the plans and specifications covered by Review of the plans and ��'C���T�?•,�,
this calculation are in compliance with the Florida Energy specifications covered by this 'tv , � "!_�,,, �.7,�,� i
Code. calculation indicates compliance ���i�,s'` , =;:`;����,_ . I
with the Florida Energy Code. �`+. ur:,:s�'+:•:=��:.�`��,,;;,�O.
�aV2 ���1G�1 � :: ,,,. �
PREPARED BY: Before construction is completed ,��, �.�,� � ,
DATE: this building will be inspected for - Lry. �„�" :w*
compliance with Section 553.908 �. �`� � �
I hereby certify that this building,as designed, is in compliance Florida Statutes. e��,� , -__ . ����
with the Florida Energy Code. �WE�
OWNER/AGENT: BUILDING OFFICIAL:
DATE: � DATE. - ' � - '
�
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as �
certified factory-sealed in accordance with R403.2.2.1. �
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage �
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn.requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in aocordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house.
3/30/2017 8:19 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
� s
� • i
FC�RM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION ,
Florida Department of Business and Professional Regulation - Residential Performance Method
�
. �
Project Name: 1791 sf ADS Builder Name: Lennar Homes '
street: 36077 Stable Wilk Avenue Perrt,it o�ice: City of Zephyrhills �
City,State,Zip: ,FL, Permit Number: �
Owner• Lennar Homes Jurisdiction: 611600 �
Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) �'
1 New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area I
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 i
b.Frame-Wood,Adjacent R=11.0 331.33 ft�
3. Numlier of units,if multiple family 1 c.N/A R= ft' ,
4. Number of Bedrooms 4 d.N/A R= ft'
b. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area 2
- a.Under Attic(Vented) R=30.0 1533.00 ft
6. Conditioned floor area above grade(ft2) 1817 b.Cathedral/Single Assembly(Vented) R=30.0 284.00 ft'
Conditioned floor area below grade(ftZ) 0 c.N/A R= ft2 ,
11 Ducts R ft�
7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 220
a. U-Factor: Dbl,U=0.54 87.00 ftZ
SHGC: SHGC=0.31
b. U-Factor Dbl,U=0.56 33.33 ftz 12.Cooling systems kBtu/hr Efficiency �
SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00
c. U-Factor Dbl,U=0.56 23.00 ft�
-SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor N/A ft= a.Electric Heat Pump 26.4 HSPF:9.00 �
SHGC:
Area Weighted Average Overhang Depth. 1.233 ft.
Area Weighted Average SHGC: 0.308 14 Hot water systems
a.Electric Cap:40 gallons �
8. Floor Types (1817.0 sqft.) Insulation Area EF 0.950
a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ftZ b. Conservation features
b.N/A R= ft' None
:
c.N/A R= ft 15.Credits Pstat �
Total Proposed Modified Loads: 54.39 pASS I
Glass/Floor Area: 0.079
Total Baseline Loads: 58.04
I hereby certify that the plans and specifications covered by Review of the plans and 0�'����'.�#r�, ,
this calculation are in compliance with the Florida Energy specifications covered by this ti ,:. "!�,+. 0,�,.
.�`, .�.
Code. calculation indicates compliance �, 'ir,°r' , 4.=:=��f�'��� ,�•
�ave �/��G� with the Florida Energy Code. � rrrarr�''=,.;,:��j rt��,,,,,t � �
PREPARED BY� Wl Before construction is completed ,w�, ���� �
DATE: this building will be inspected for try_ �Ef(i.-. �* �
compliance with Section 553.908 *' �� ',�-
I hereby certify that this building,as designed, is in compliance Flonda Statutes. �,,�; �r�+�
with the Florida Energy Code. G��•ti1'E`�
OWNER/AGENT. BUILDIN OFFICI .
DATE: DATE: ������ � '�
I
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as i
certified factory-sealed in accordance with R403.2.2.1. ,
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage ,
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house.
3/30/2017 8:19 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
. �
FORM R405-2014
' PROJECT
Title: 1791 sf ADS Bedrooms: 4 Address Type: Street Address �
Building Type: User Conditioned Area: 1817 Lot# _ ;
Owner• Lennar Homes Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: Yes PlatBook: �
�
' Builder Name: Lennar Homes Rotate Angle: 45 Street: I
Permit Office: Cross Ventilation: County Pasco �
Jurisdiction: Whole House Fan: City,State,Zip: !
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
\� Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium
BLOCKS �
Number Name Area Volume I _
1 Block1 1817 14536
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated
1 Main 1817 14536 Yes 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 155 ft 0 1817 ftz ___ 0.3 0 0.7 i
ROOF - I'
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch i
V # Type Materials Area Area Color Absor Tested Tested Insul. (deg)
1 Hip Compasition shingles 1968 ft2 0 ftz Medium 0.85 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC ;
1 Full attic Vented 300 1817 ft' N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 1533 ftZ 0.11 Wood !
I
2 Cathedral/Single Assembly(Vented) Main 30 Blown 284 ft' 0.11 Wood i
�
3/30/2017 8:19 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Soflware Page 2 of 4
, , �
FORM R405-2014
' WALLS
Adjacent S a� Cavity Width Height Sheathing Framing Solar Below
P _ o
_ 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 19 6 8 156.0 ft2 0 0.600000 0 '
_2 N=>NE Garage Frame-Wood Main 11 20 8 8 165.3 ftZ 0 0.01 0 I
_ 3 W=>NW Garage Frame-Wood Main 11 20 9 8 166.0 ft' 0 0.01 0 I
_4 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 58 8 464.0 ft' 0 0.600000 0 i
_5 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft� 0 0.600000 0 �
_6 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 37 8 8 301.3 ft� 0 0.600000 0
_7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft' 0 0.600000 0
DOORS �
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>NE Insulated Main None .2 3 6 8 20 ft2
2 N=>NE Wood Main None 4 2 8 6 8 17.8 ft2 i
' WINDOWS �
' Orientation shown is the entered orientation(_>)chan ed to Worst Case.
/ Wali Overhang
�� # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 23.0 ftz 1 ft 0 in 3 ft 8 in Drapes/blinds None
2 E=>SE 4 Metal Low-E Double Yes 0.54 0.31 32.0 ft2 1 ft 0 in 0 ft 4 in Drapes/blinds None ,
3 S=>SW 5 Metal Low-E Double Yes 0.54 0.31 32.0 ft2 1 ft 0 in 0 ft 4 in Drapes/blinds None �
4 S=>SW 7 Metal Low-E Double Yes 0.56 0.32 33.3 ft� 2 ft 0 in 0 ft 4 in Drapes/blinds None I
5 W=>NW 6 Metal Low-E Double Yes 0.54 0.31 23.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None
GARAGE
# FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 429 ft2 427 ft2 42 ft 8 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 �
1 Wholehouse Proposed ACH(50) .000254 1211.3 66.5 125.06 1906 5 �
HEATING SYSTEM �
i
_ # System Type � Subtype Efficiency Capacity Block Ducts i
1 Electric Heat Pump None HSPF:9 26.4 kBtu/hr 1 sys#1
I
I
3/30/2017 8:19 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 3 of 4
FORM R405-2014
' COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts i
1 Central Unit Split SEER:15 30 kBtu/hr 900 cfm 0.85 1 sys#1 i�
- i '
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF ,
None None ft= _
DUCTS
/ —Supply— --Retum— Air CFM 25 CFM25 HVAC# i
�� # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 220 ft2 Main � 75 ft2 Prop.Leak Free Main —cfm 54.5 cfm 0.03 0.60 1 1 I
TEMPERATURES ;
Programabie Thermostat:Y Ceiling Fans: I�
Coolin Jan Feb Mar A r Ma X Jun X Jul [X Au X Se Oct Nov Dec ,
Heating �Jan �Feb f X�Mar f �Apr f �May 4 �Jun 4 �Jul [ �Aug 4 �Sep f �Oct �Nov �Dec
Venting Jan Feb [X Mar [X]Apr ( May [ Jun [ Jul [ Aug [ Sep [X Oct Nov Dec �
Thermostat Schedule. HERS 2006 Reference Hours 'i
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 '
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(V11D) AM 66 66 66 66 66 68 68 68 • 68 68 68 68 I
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(VI/EH) AM 66 66 66 66 66 68 68 68 68 68 68 68
' PM 68 68 68 68 68 68 68 68 68 68 66 66 �
I
I
I
I
3/30/2017 8:19 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 �
i
FORM R405-2014
• ' i
ENERGY PERFORMANCE LEVEL (EPL)
,
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94 i
The lower the EnergyPerformance Index, the more efficient the home. �
�
„ F�,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 1241.30 ft2
b.Frame-Wood,Adjacent R=11.0 331.33 ft2 ,
3. Number of units,if multiple family 1 c.N/A R= ft�
4 Number of Bedrooms 4 d.N/A R= ft�
10.Ceiling Types Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1533.00 ft2
6. Conditioned floor area(ft�) 1817 b.Cathedral/Single Assembly(Vented) R=30.0 284.�0 ftZ
7 Windows" Description Area c.N/A R= ft2
�
a. U-Factor Dbl,U=0.54 87.00 ftZ 11 Ducts R ft �
a.Sup:Attic,Ret:Main,AH:Main 6 220
SHGC: SHGC=0.31 '
b. U-Factor: Dbl,U=0.56 33.33 ft�
SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency ,
c. U-Factor Dbl,U=0.56 23.00 ftZ a.Central Unit 30.0 SEER:15.00 '
SHGC: SHGC=0.28
d. U-Factor. N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC� a.Electric Heat Pump 26.4 HSPF:9.00
Area Weighted Average Overhang Depth: 1.233 ft.
Area Weighted Average SHGC: 0.308
8. Floor Types Insulation Area 14 Hot water systems
� a.Electric Cap:40 gallons ,
a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft EF�0.95
b.N/A R= ftZ
c.N/A R= ft� b. Conservation features j
None
15.Credits Pstat �
I certify that tfiis home has complied with the Florida Energy Efficiency Code for Building :�.�.E:Sr
Construction through the above energy saving features which will be installed (or exceeded) ;�;p� . T,`�TL•'4.
in this home before final inspection. Otherwise, a new EPL Display Card will be completed krQ','`',• :==:,`,;''�c.
y} f�l, . , ..?'=..�oc�a t'
based on installed Code compliant features. - � fr�F,�,����,,,.;::;����;;��u;, t�
. �:.:, .. - �
Builder Signature: Date. 04/10/17 � ����'�'��• � �
4:�
# ��. �
Address of New Home: 36077 Stable Wilk Avenue City/FL Zip Zephryhills,FL33541 '�!c ��`�''
��j y�� . "
*Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy e�cient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) !
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
_ staff.
I
'`*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/30/2017 8:20 AM EnergyGauge�USA-FlaRes2014 -Section R405.4.1 Compliant Soflware Page 1 of 1
r �
Buildin Anal $�$ Jo6: 1791 sfADS
g Y Date: 3l30/2017
En tire Ho use By: Dave
BAYON�T PLUMBING COOLING HEATING �
' � - • •
For Lennar Homes
- i
i - • o • •
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD (°F) 39 16
Latitude: 28°N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7
Dry bulb(°F) 31 91 � Infiltration:
Daily range(°F) - 14 ( L ) Method Simplified
Wet bulb(°F) - 77 Construction quality Semi-tight ,
Wind speed(mph) 15.0 7.5 Fireplaces 0 '
� '
•
Component Btuh/ftZ Btuh % of load
Walls 5.6 6070 24.2
Glazing 30.2 4851 19.3 _ �
Doors 23.5 480 1.9
Ceilings 1.3 2271 9.0
Floors 3.4 6125 24.4
Infiltration 2.1 2715 10.8 '
Ducts 2616 10.4
Piping 0 0 �..
Humidification 0 0
Ventilation 0 0
Adjustments 0 -- "�
Total 25127 100.0
• • �
Component Btuh/ftZ Btuh % of load
Walls 2.8 3020 13.5 d��
Glazing 48.4 7781 34.8 '
Doors 18.4 376 1.7
Ceilings 1.7 3140 14.1 j ,. '
Floors 0 0 0 � j
Infiltration 0.5 608 2.7
Ducts 2983 13.3
Ventilation 0 0 �
Internal gains 4440 19.9 ° .:t ,
Blower 0 0 °'�
Adjustments 0
Total - 22347 100.0 �, �
Latent Cooling Load= 3398 Btuh
Overall U-value= 0.103 Btuh/ft2-°F
Data entries checked.
� wri htsoft`� 9 2017-Mar-30 08:23:27
9 Ri ht-Suite�Universal 2013 13.0.09 RSU05714 Page 1
� H:\LENNAR LOADS\1791 sf ADS drawn 2.Ston.rup Calc=MJB Front Door faces: S
Pro ect Summa Job: 1791sfADS
1 � Date: 3/30/2017
fntire House By: Dave �
BAYONET PLUMBING COOLING HEATING
�
, I
' o - o • i
, i
For: Lennar Homes
Notes:
0 - � s s ,
Weather: TamPa International AP, FL, US
Winter Design Conditions Summer Design Conditions �
Outside db 31 °F Outside db 91 °F
Inside db 70 °F Inside db 75 °F �
Design TD 39 °F Design TD 16 °F �
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/Ib ,
Heating Summary Sensible Cooling Equipment Load Sizing �
Structure 22512 Btuh Structure 19364 Btuh �
Duct� 2616 Btuh Ducts 2983 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh -
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 25127 Btuh Use manufacturer's data y �
Rate/swing multiplier 1.00
Inflltratlon Equipment sensible load 22347 Btuh �
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 2861 Btuh
Ducts 537 Btuh ;
Heating Cooling Central vent (0 cfm) 0 Btuh
Area(ft2 1817 1817 Equipment latent load 3398 Btuh -
Volume�ft') 14534 14534
Air changes/hour 0.26 0.14 Equipment total load 25744 Btuh ,
Equiv.AVF(cfm) 63 34 Req. total capacity at 0.85 SHR 2.2 ton
Heating Equipment Summary Cooling Equipment Summary �
Make Lennox Make Lennox
Trade 14HPX SERIES Trade 14HPX SERIES
Model 14HPX-030-230-18 � Cond 14HPX-030-230-18 �
AHRI ref 5186991 Coil CBX27UH-030-230*++TDR
AHRI ref 5186991
Efficiency 9 HSPF Efficiency 13.0 EER, 15 SEER
Heating mput Sensible cooling 25500 Btuh i
Heating output 26400 Btuh @ 47°F Latent cooling 4500 Btuh �
Temperature rise 24 °F Total cooling 30000 Btuh ;
Actual air flow 1000 cfm Actual air flow 1000 cfm '
Air flow factor 0.040 cfm/Btuh Air flow factor 0.045 cfm/Btuh i
Static pressure 0 in H20 Static pressure 0 in H20 �
Space thermostat Load sensible heat ratio 0.87
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
^ "� wrightsoft°' Right-Suite�Universal 2013 13.0.09 RSU05714 2017-Mar-30 0 Page 1
'�� H:\LENNAR LOADS\1791 sf ADS drawn 2.5ton.rup Calc=MJB Front Door faces: S
� l.
Manual S Compliance Report Job: 1791 sfADS
Date: 3l30/2017
En tire Ho use By: Dave
BAYONET PLUMBING COOLING HEATING �
. ;
i
i
• a • o
For Lennar Homes �
• . . • .
Design Conditions _
Outdoor design DB. 91.3°F Sensible gain: 22347 Btuh Entering coil DB 75.7°F
Outdoor design WB� 77.3°F Latent gain: 3398 Btuh Entering coil WB� 62.8°F
Indoor design DB 75.0°F Total gain: 25744 Btuh
Indoor RH. 50% Estimated airflow� 1000 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Nlanufacturer: Lennox Model: 14HPX-030-230-18+CBX27UH-030-230'++TDR
Actual airflow: 1000 cfm
Sensible capacity� 24670 Btuh 110% of load �
Latent capacity: 4360 Btuh 128% of load
Total capacity: 29030 Btuh 113% of load SHR. 85%
• . •
Design Conditions
Outdoor design DB 30.8°F Heat loss. 25127 Btuh Entering coil DB. 69.6°F
Indoor design DB: 70.0°F ,
Manufacturer's Performance Data atActual Design Conditions
Equipment type: Split ASHP
Manufacturer� Lennox Model: 14HPX-030-230-18+CBX27UFi-030-230'`++TDR
Actual airflow� 1000 cfm
Output capacity: 26400 Btuh 105% of load Capacity balance: 37 °F
Supplemental heat required: 0 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip ,
Manufacturer n/a Model: n/a+nla
Actual airflow: 1000 cfm " �
Output capacity: 0 kW 0% of load Temp. rise: 0 °F ,
The above equipment was selected in accordance with ACCA Manual S.
.� wri htsoft` 2017-Marv30 08:23:27
�� � 9 Right-Suite�Universal 2013 13.0.09 RSU�5714 Page 1
�� H:\LENNAR LOADS\1791 sf ADS drawn 2.Ston.rup Calc=MJB Fronl Door faces: S
I
_ _ - ;i
� r
�' � ` � � PASCO COUNTI( �
� �
�._,,ti BUILDING CONSTRUCTION SERVICES
��� 8'T3'I Citizens Drive Date:7/28/2017 �
•r — • d
' Suite 230 �
V "�' New Port.Rictiey,FL 34654 �
_ ��;�°•' 727-847-8127
�
7:� 8 ��� �. ���,GV9�� *�
Record#: 06FOS=00000�#OOOb �
Analicant Information Contractor Information Owner Information I
, , �
Proiect Information �
Status:#POS Applied:04/1112016 Issued:
TyPe:_PER_TYPE Finaled: Expired:
Gategory:_PER CA'I'EGORIf
Su6=Type:_PER SUB T1(PE
Parcel Number:
.lob:Adciress:
11Uork Description:
FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE.# .FEE AMOUNT PAID RECEIPT# DATE
TOTALS: '
�
Receipt# Paid Bv Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid
�1696362 Check 881848 :294 BCCCP38W 07%28/2017 $27_88
Total Payments: $27:88
Pavor Address Phone
LENNi4R
om ts•
3 77 STABLE VUILK AV .ZHILLS"SW FAYMNT.PERMIT#18614
02895 ennar Homes,LLC JPMorgan�'Chase Bank NA. STUB CHECK NO. 881849
lNVo10E 900000.1010:914 1 .of 1 ; 'DATE Q7/20/17�.
CD..#.._ _ NUMBER _ DATE.- - PAYtifEA'TADYlCE GROSS DISCOUNT- NET
15224 1'S224720131.40.1435 071017 15224720131401435 , . S27.88 ' 50:00 $27_38=
t
_ _
�� ,t .
��,� � -
� � w � . -- � � -
_ �`' � l
� � i
� '
�� � �'`� ' ' ! _
� ��� �
! —,
6820202- Ciry of Zephyrhills FBA Tntd -Bihm 49,;8144 ,
5335 Bth SYtreet -_ $27.88� 50.00 - '$27.88