Loading...
HomeMy WebLinkAbout17-18615 . ,� CITY OF ZEPHYRHILLS ,, ,,,f� :� 5335-STH STREET (sts)�so-oo20 15 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL " � PERMIT INFORMATION ` � LOCATION INFORMATION Permit#:18615 Issued: 6/28/2017 Address: 6551 PADEN WHEEL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. � Class of Work: 101-NEW CONST/SFR Township: Range: I Proposed Use: NOT APPLICABLE Lot(s): Block: Section: � Sq. Feet: Est. Value: Book: Page: � Cost: 494,148.56 Total Fees: 12,420.69 Subdivision: SILVERADO Amount Paid: 12,420.69 Date Paid: 6/28/2017 Parcel Number: 05-26-21-0070-00400-0080 CONTRACTOR.INFORMATION OWNER INFORMATION - Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 15550 LIGHTWAVE DR Address: 4600 W. CYPRESS ST STE 200 CLEARWATER, FL. 33760 TAMPA, FL 33607 Phone: (727)479-1740 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY HOME 4,646 SQ FT APPLICATION FEES BU DING FEE 1,786.45 ELECTRICAL FEE 376.43 PL MBI G FEE 250.95 MECHANICAL FEE 175.67 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfd100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 4828 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 ���� � { n � , 1 ` r/, /( � .i'I `� l � . e���� .��� �1�- � 2' , � � � Ins ections Re uired FOOTER 2 D ROUGH PLUMB MIS INSULATI CEI NG � FOOTER BOND DUCTS INSULATED SEWER MISC. � ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. , DUCTS INSTALLED WATER MISC DRIVEWAY ! PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. � REINSPEC3ION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local governmer�t shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this properly that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. ' , "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for imp�ovements to your properly. If you intend to obtain financing,consult with your lender or an attorney ! before recording your notice of commencement." I Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. � I I � ----�' � CONTRAC ORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER i � Cr.-ystal'R.epo�ts V�e�ver Page 1 of'1 ��3__ . '• � �00%.. ;cR,y,aihi.sE�.n78� ��',g;J�'PeremHeis��roupSroe,�i t1 f;�0'Jt 'v.,�S�=('y;(��,'`����,i d7ata Reper! . , . � . . � p ' PASC6 COlIN'iY 9UILDING CONSTRUCTIpN SERVIC�S, � �""�� 9731 COfzens,Drive 11h.. Dale:7/311Z017,. 8ui1e�230 j .�� Naw Poh Rlchey;Fi.34659 , �27-847-5127 i ��: . .;� � i '��` NC}T A PE�RII/EIT �'� ; - , Rece,ipt#� 1696885 ' � ; i FEEDESCRIPTION ACCOUNTCODB NITS NVI OICE,k'FEEAlI�OUNT PAID RECEIPi6 pA7E Impact Fee�Res3de4tla15olid -'8d50-3C+3400 27�88 1274325 527.88 527.86 i6968$5 7131ti7 Waste S(ngle Fain(ty � ] � TbTAL5:; 527:88 E27•88 Reco t!! Paid@v Chockf!' CCAuthN dashieritl 'Woikstation, Reca�otDate g,mtPaid� 1698065 Check 881854' 294 BCCCP3BW 071312q17- S27:B8, � Tntai Pny,mentat. 'S2'f.88� i pavor "es P o e LENNARHOME3 8551'pADEN.WHEEL$T ZHi�US SW PYMNT= , PERMIT#78615 Cammente; - � 0548210070DOA40UD80 I I, i —' , ' I � '�' - - , , i 02895856 Lennar Ho�nes;.LLC JFMorgan Chase Bank_N:A. � S7'UB CHECKNO. ,881$$4. �INY.OIG'E - 900000.1010.114 � � 1 af 1 � pATE'.07l20/17 i CD.# NUA?6ER DAT6 PAYMEN7'r1DVICE GROSS DISC'OUNT 'NET �� � - . .. .. ; lS225 :1_522571p408.40,1,435"-•. ,'471QL7 15225?104084Q1435 $2?.88 ' .�4.OQ $2'T;88 . , �� ' � � : �" ,� , ,� ��J. ; �. - �� ' .- � � _ ���' �( - t ,�- , �`� ,c � ���� . . . V� ;�� � : � � � � Qr�� t , , t. ; ,.; :, 6820202 �rryofZephyriills' FBATmdy Bihtti49-81AA' ' - -' " � 5335,8th StreeC J . $27:88 _50.00� $27.88• . Ze h rhiIt"s FL 33542 ' ; � . , (. . �; http://crystal3.acce�a:com/niyreparts/adapter/XReportmp:aspx?re... 7%31.1201�7 � � -' CITY.OF ' / / / / BUILDIN� ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION � • • - • ADDRE55 DATE PERMIT f ' ��v, _. - ` /'�� � THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections sholl be made before the job will be accepted. D �,� It is unlawful tor any Carpenter,contractor,Bui�der,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any paR of the worlc with flooring,lath,earth 780-0020 FOR RE-INCP CTION or other material,until the proper inspector has had ample time to approve y the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR � ' CITY�OF ' / / I / BUILDING ZEPHYRHILLS DEPARTMEt�T . OF ADDITION OR CORREC�'ION � • • - • ADDRESS DATE � PERAAIT�, w � 7` z- � � THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be mode before the job • will be accepted. ,�� .� ` S ��P i �� ��� ,�!��c�_ , '�� It is unlawtul tor any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE ADE CALL cover or cause to be covered,any paR of the worlc with flooring,lath,earth ' or other material,until the proper inspector has had ample time to approve 780-0020 FOR RE- , SP TION ' the installation, i ' � � . ,. ' . OFFICE HOURS 7:30AM-4:30 PM MON-FRI. INSPECTOR _ ' � r � CITY•OF ' / / / / BUILDIN4 2EPHYRMILLS DEPARTMENT OF AaDlTION OR C��RR��TIUN r� • • - �r ADORfSS � DATE PERMIT# }��� �,SS/ � /� (-2,Z ! THIS JOB HAS NUT BEEN COMPLETED. 7he following additions or corrections shall be made 6efore the job will be accepted. � 141�/l �W! � �4 ��K � � , i It is unlawful tor any Carpenter,Conhactor,Builder,or other persons,to AFTER CORRECTIONS ARE M!#DE CAL.L cover or cause to be covered,any part of the work with flooring,lath,earth or other materiat,untii the proper inspector has had emple time to approve 780-0020 FOR RE-�N PECTI4N . the installation. OFFIGE H4URS 7:30AM-4:30 Pitt1 MQN:FRI. INSPECTOR � I i � � Lennar Homes-6551 Paden Wheel St-4,646 sq ft ' �p$ I � - SQ.FEET PRICE _ MAIN OR LMNG: 4,646 $ 106.36 � OTHER AREA UNDER ROOF: _ g gg,p� OTHER: - $ . VALUATION $ 494,148.56 FEE SHEET $ 1,673.00 - ADDRESS $ 40.� - - - DRNEINAY $ 40.00 - BUILDIMG: $ 1,786.46 ELECTRICAL; $ 376.43 PLUMBING: $ . 2yp,g5 MECHANICAL:'$ �75.67 - SUB=TOTAC $ 2,589.50 TOTAL $ 2,589.50 SEINER: na WATER: - na IRRIGATION: $ - TOTAL: $ . � - WATER MEfER: na . • fRRIGATION METER $ FIRE DEPARTMENT FEES: PLANS TOTAL: !na INSPECTION TOTAL: " PERMITTOTAL- TOTAL: $ . � PUBLIC SAFETY IMPACT FEES POLICE,$ _254.00 FIRE $ _273.00, 5%..$ 26.35 , TOTAL: $ 553.35 SUB-TOT.AL ,$ 3,142.85 ' PARK IMPACT FEES $ 769.56 ' '" SIF'S: `$_ 4,828.00 100.0%,$ _ 4,828.00 1.0% $ 48.28 . TOTAL: y 4,876.28_ _ T I P'S: $ 3,632.00 -- � 99% $ 3,595.68 - - 1°/a $ 36.32 TOTAL: $ 12,420.69 - —'=.tc^ � _- _ ' Y � � � � �� PASCO CQUNTY, FLC►RIDA , . . � Permit No. j���� Date i'ermitted � Builder NamelOwner Name �„Q�y�,f--��d77�tE'�' Contro!# , , County Parcel No, ��-��'2-f�� 7D--Q 0 D -l��Subpiw �l 1 I��� ; ' AddresslLocation � G2(if Z°vt � �.J� j � 'ClassificationiType of Use <� �' f� r �TRANSPORTATiON IMPACT FEE Rate: Sq Ft Unit Tj �7 k� � ;Exempt []Yes �} No How Determined � ,impact Fee Amount $ �! ��' Zone No. TAZ: . SCHOdL 1MPACT FEE t2 � ,Account (Q56) Single-Family Detached House Amount $ _ '�a V�� ! Z'� ' � (087) Mobite Home ! (458) Other Resldential � - �i 23} Coilection Fee �Exsmp# �] Yss Q No � Now�petermined � ;PARKSAND RECREATIf3N FEE Land Account Land Credit Land Totai . ;Recreation Account Recreation Credit Recreation Tatai , Zbne � TOTAL AM(JUNT $���c7.�a � ;Exempt � Yes � No How Determined � �, _ � 'LIBRARY FEE ' Land Account Land Credit Land Tota! � ' Facjlity Accaunt Facilify Credit Facility Tota! ,Exempt [�Yes [� Na How Defermined Tota!Amount��` � - . � RESOIiRCE FEE ERU , � .TOTAL AMOUNT _ � _ i �Prepared By � GhBGked Sy i , � NO CERTlP{CATE OF OCCURANCY WiLL SE tSSUED t)R FINAL INSPECTIUN � � PERFORMED UNTIL THE TOTAL AMOUN'fS LISTED HAVE j BEEN PAtD AND ' � RECEIP7ED FOR SY A CENTRAL PERMITTING OFFICE OF PASGQ GOUNTY I Acknowledgement be(ow does not Impiy acceptance of concurrence,but slmply recelpt of a copy at thls form,piactng ' � the building parmtt owner on notlee of thls assessmanY and thQ conditfons af payment for same. DATE REGE{VED BY RECEIPT R10. DATE BY � J . . .. � i i � 1 I I'�III IIIII IIIII II'll II'll I'll'IIIII III'lllll'IIIII IIII I'll . 2017099197 Rept: 1873844 Rec: 35.50 ( DS: 0.00 IT: 0.00 I 06�23J2017 eRecording ! I Tlds Instrument Was Prepared � ' By And Shoald Be Returned To: PAULA S.O'NEIL,Ph.D.PASCO CLERK 8 COMPTROLLER 06/23/2017 09:46 AM 1 af 4 ' � I.ee E.Nelson,Fsyuire OR BK �5�� PG gg� , Shutts&Bowen LLP ' 4301 W.Boy Scout Blvd.,Suite 300 Tampa,Florida 33607 , � � ; ; � MEMORANDUM OF OPTION TO REPURCHASE I � THIS MEMORANDiJM OF OPTION TO REPURCHASE (the "Memorandum") is , made and effective this Z 2 day of �i.H� , 2017, by and between DUNE FL LAND I � SUB, LLC, a Delaware limited liability company ("Seller") and LENNAR HOMES, LLC, a , Florida limited liability company("Purchaser"). � RECITALS: � i WHEREAS, Seller and Purchaser have heretofore entered into a Lot Purchase and Sale I Agreement, with an effective date of July 7, 2015, as amended (collectively, the "Agreement"), ' for the purchase and sale of property located in Pasco County, Florida, as more particularly described therein,and WHEREAS, Pursuant to'the Agreement, Purchaser has concurrently herewith, closed its ' purchase of the following: I See Exhibit "A" attached hereto (each individually the "Lot" or collectively the ' "Lots"). WHEREAS, Purchaser's purchase of and closing of the Lots is with the intention and for the purpose of Purchaser's consiruction thereon of a single family home,and WHEREAS, pursuant to Paragraph 21 of the Agreement, and pursuant to the terms and '' conditions set forth in this Memorandum,Purchaser has given and granted to Seller the option to � repurchase the Lot(s) in the event that Purchaser desires to sell such Lot(s) prior to its I constntction of a residence thereon, or prior to entering into a written contract to consttuct a residence on such Lot(s)for its intended purchaser, NOW THEREFORE, for and in consideration of the premises hereof,the mutual covenants herein contained and for other good and valuable considerations,the receipt and sufficiency of all of which are hereby acknowledged,Seller and Purchaser do hereby covenant and agree as follows: � � Section 1. Recitals. The above recitals are true and correct and constitute part of this � Memorandum. -� ' �q'` i ,� ' , OR BK � '�,,,�' �3 pG 9�9 4 of 4 EXHIBIT"A" Lots 30 and 31,,Block 1,_SII;VERADO RANCH SUBDIVISION PHASES 2, 3 &4;according.� to tfie plat thereof as recorded in Plat Book 73, Page 59 et seq., of the Public Records of Pasco � County,Florida. ; � AND ! Lot 11, Block 2; SILVERADO RANCH SUB.DIVISION PHASES 2; 3 & 4, according to the � plat tliereof as iecorded:in Plat Book 73;_Page 59.et seq:,of the Pnblic Records of Pasco County, � , Florida.�� - - -- � - i I AND � Lots 7 and 8, Block 4; SII,VERADO RANCH SUBDIVISION PHASES 2, 3 &4, according to � tlie�plat thereof as recorded in Plat Book 73, Page 59 et seq., of the Public Records of Pasco I County,Florida. � � TPADOCS 21618733128053.0162 � I � � i • • OR BK g563 pG ��7 � 2 ot �1 Section 2. Option. Purchaser does hereby ratify and confirtn those provisions of Paragraph 21 of the Agreement pursuant to which Purchaser has granted to Seller, and Purchaser does hereby grant to Seller, the option to repurchase any Lot in the event that Purchaser desires to sell such Lot (a)prior to its construction of a residence thereon, or (b)prior to entering into a written contract to construct a residence on such Lot for its intended purchaser(the "Third Party Buyer"). Section 3. Term of Option. Purchaser and Seller agree that the option rights described in Section 2 of this Memorandum shall immediately terminate as to each Lot without the necessity of recording a termination hereof in the Public Records of Pasco County, Florida upon the issuance of building permit from Pasco County, Florida for the residence on such Lot (the "Termination Date"). For the avoidance of doubt, the Terinination Date shall be established as a matter of public record upon Purchaser's conveyance by deed of the Lot to a third party buyer. ; Section 4. Bindin�ffect. The provisions of this Memorandum and Paxagraph 21 of the Agreement sliall run with title to each Lot, as the case may be, and shall hereafter be binding , upon Purchaser and its successor and assigns until the Termination Date. IN WITNESS WHEREOF, the parties hereto have caused this Memorandum of Option � to Repurchase to be executed as of the date first written above. WTTNESSES: ASSIGNOR: , DIJNE FL LAND I SUB,LLC,a Delaware ; limited liability company i��� � B �. , y� � Print Name ohn M.Ryan,Manager � ; � Print Name • STATE OF FLORIDA ) ; )ss.. ' COUNTY OF HILLSBOROUGH ) � � The foregoing instrument was acknowledged before me tlus�j day of � 2017, by Jobn M. Ryan, as Manager of DUNE FL L�A�H I SUB, LLC, a elaware limited liability company on behalf of the company, who (�is personally known to me or �) has i produc or identification. - i i � � Not y Pnblic My Commission Expires: y���� ' saa+r� ""'•� KELLEY RHMNIEL �: �,, :��..;;�: :.• ._ NIY COMMISSION�GG 073177 z�,,oP' q E�(QfRES:Mey 91,2021 ���t°`: BprbedthtuNolarYP�6cUnde�w�ers � • i I • OR BK 9��� PG g�s i + 3 ot +1 � WI`INESSES: ASSIGNEE: ' LENNA.R HOMES, C, a Florida limited liability comp I i B � Pnnt Name N Its: 1 �' j� ; r�. �,�:�� ���� Print Name f�Q�,.. 1�,VC�i�v►Ci.,�f i � STATE OF 1' 1 )ss.. ; COUNTY OF ' The foregoing instrument was acknowledged efore me this�day of , � 2017, by i L. as �C.f_. �� l� � "�' of LENNAR HOMES, LLC, a Florida limited lia ility c mo pany, on behalf of t he company, w ho is � personally known to me or (__)has produced for � identification. . , ���� . � Notary Public My Commission Expires:3��Q���� ' W. cARDINALE �dOT/4RY PllBLfC i �YATE OF�LORIPA I . ". . � Ca�FF0992A8 i Exptres 3/6/2p1� I i iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii . . . . , • 2017101190 IIII � � Rcpt:1874825 Rec: 10.00 DS: 0.00 IT: 0.00 06/27/2017 K. K. , DptY Clerk �—.-- • PqULR S 0'NEIL,Ph D,PASCO CLERK & COMpTROLLER 06/27/201� 01:14 m 1 of 1 OR BK �5 �'� p� 3�10 Perinit No. Parcel ID No 05-26-21-0070-00400-0080 NOTICE OF COMMENCEMENT State of Florida County of Pasco • , THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Floride Statutes, � the following information is provided in this Notice of Commencement: 1 Description of Property� Legal SILVERADO RANCH SUBDIVISION PHASES 2,3,&4 PB 73 PG 59 BLOCK 04 LOT 08 st�eetAdd�e55. 6551 Paden Wheel Street Zephryhills FL 33541 2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence - 3 Owner Information: Lennar Homes, LLC. Name 4600 W Cypress St. Ste 200 Tampa FL. 33607 . � Address City State „ � Interest in Property� , Name of Fee Simple Titleholder• N�A ' (If other than owner) Address City State a contractor: Lennar Homes, LLC , � Name ' 4600 W Cvpress St, Ste 200 Tampa FL, 33607 " � �i Address City State , Contractor's Telephone No.. 813 574.5700 5. Surety: S ."� :` N/A Name � Address Cit State � Y Amount of Bond: $ Telephone No.'. � s. Lender N/A ' Name � Address City State , Lender's Tele,{�hone No.. i - 7. Persons within the State of Florida designated by ihe owner upon whom notices or other documents may be served as provided by - Section 713.13(1)(a)(7),Florida Statutes: � � Lennar Homes. LLC - Name i4600 W Cvpress St, Ste 200 Tampa FL, 33607 , Address City State � Telephone Nurtiber of Designated Person: 813.574.5700 ' 8. In addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner 9 Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: � � WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT � ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. . ' i . STATE OF FLORIDA ' ' COUNTY OF PINELLAS �� - - Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager , � Vice President Signatory's Title/Office The foregoing instrument was aclinowledged before me this 6 day of Mafch ��f 7 ,by SteVe Smlth as ViCe Pfesident (type of authority,e.g.,officer,trustee,attorney in fact)for �Lennar Homes LLC ame o y on be om instrument was executed).- 1 Personally Known■OR Produced Identification❑ Notary Sign ure Type of Identification Produced Name(Print) Elissa Holleran ' Verification pursuant to Section 92.525, Florida Statutes. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in ' ' it are true to the best of my knowledge and belief. � . � � " � ' �� ,,,, � , ;��;ELISSAM.HOLLERAN � Signature of Natural Person Signing Above , i s* ;,�C�mml�elon�FF 88583T � o°Ex'Irea June 6,P020 - wpdata/bcs/bcs form;, ,�0f���� �ndNThNTroyFolhlMunneel00a0.5-701Y � ������(�8���� , �� � � � �� STATE OF FLORlDA, COUNTY.OF PASCO �a �}A'� : '-�t � ' THIS IS TO CERTIFY THAT 7HE FOREGOING IS A � �� `��P�'�`� � ' t��� :,��•,.. TRUE AND CORRECT COPY OF',,THE DOCUMENT � � � �. � •' � ON FILE OR OF PUBLIC RECORD IN THIS OFFICE ;��,. ��` � �:.Y.. WITNES�S MY HANDA U OFFICIALSEALTHIS �� � �,��7, • � .��DAYOF� 2 b /% ��:�:,_:;.� , a,�.�.�� PAULAS O'f�lEIL, CL RK&COMPTROLLER �6�i�°���'� I gY P��j �(�L�.�BEPUTY CLERK � ; , ' /��Q'��-o st�:. "�:/' :;'�;"� J�x,,�:y - �� = : =j�r�-� .�..,a�:ss :.�`k �s.,:�c...,`._�� � City of Zephyrhills BUILDING PI�AN REVIEW C011tIMENTS Cantractor/Homeowner: � ,- Date Received: �~����� s�t�: l ��� ����� �r���� r �j ���s�• � Pernut Type: � � �l�' l 1 Approved wlno comments:❑ Approved wfthe below comments� Denied w/the below camments: � t 1 � , � �P� � ; This comment sheet shall be kept with the pennit and/or plans. r�"�1 J Kalvin i zer ans Examinex Date Cantrac or andlor Homeowner (Required when comments are present} ; � i iI I 813-780=0020 City of Zephyrhills Permit Application Fax-a�saso-oo2� Building Department ' � Date Received �i, I Phone Contact for Permittin 813 363 _ 2891 Owner's Name 'Lennar Homes,LLC Owner Phone Number 813.574.5700 Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name N�A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 6551 Paden Wheel Street LOT# 0080 I SUBDIVISION Silverado Ranch Subdivision Ph 2,3,&4 pqRCEL ID# 05-26-21-0070-00400-0080 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED II�/ I� NEW CONSTR e ADD/ALT � SIGN 0 Q DEMOLISH � INSTALL REPAIR PROPOSED USE � SFR Q COMM 0 OTHER TYPE OF CONSTRUCTION � BLOCK Q FRAME � STEEL 0 DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF 4520 SQ FOOTAGE 3711 HEIGHT 2 StOry ✓ BUILDING $ �/,1�"� VALUATION OF TOTAL CONSTRUCTION �1� � I�/ 'ELECTRICAL $ � PROGRESSENERGY � W.R.E.C. '� � AMP SERVICE �PLUMBING $ � ���/ �MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION ��� � � • � I� �� QGAS � ROOFING Q SPECIALTY 0 OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA �YES I �JO i�r u -�NT:��Fr�H-1--1--{-F-1--F-1�-1-F-�1-�-H-�- 1-FFI--��H-f--1--4-1--1--1-f-�1-��1--�-1-{�F:-FG--G--�-N�F-�•f--{�-F-1- BUILDER ` COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4600 W.Cypress St.Ste.200,Tam a,FL 33607 License# CGC1518166 ELECTRICIAN COMPANY Edmonson Electric, �C1C. SIGNATURE REGISTERED Y/ N FEE CURREN Y/N i Address 1034 Skipper Road, Tampa, F 33613 �icense# EC13005408 �il P�umseR COMPANY Bayonet Plumbing, Heating &AC, Inc � SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, Bayonet, FL 346 4-5308 �icense# CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc �� SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Addr`ess P.O. Box 5308, Bayonet, FL 34 74- 308 �icense# CAC058062 OTHEI2 COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4211 Shoal Line Blvd, Spring Hill, FL 34607 �icense# CCC057991 � � � � � � i � � � � � � � � � � i � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �-� � � � RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects _ COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster Site Work Permit for all new projects.All commercial requirements must meet compliance - SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. ..1..4�1..4..1���L..1-�.' '�G��' I..L��1-1..��1..���1..��1..��1.-4-1..1..4.1..1..4.1..4.1..1.-f-���1..��4�1..��1..4�I�f..��1.. Uirections: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) '* Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(PIoUSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW I NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands � that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended) If valuation of work is$2,500 00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. '� CONTRACTOR'S/OWNER'S AFFIDAVIT I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. i also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalis, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill. - Use of fill is not allowed in Flood Zone"V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTOR EY BEFORE RECORDING YOUR OTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before m thi Subscribed and sworn t r affirmed)before me this un-Hpr-i i by paul Sweeney Ofi-Apr-17 by Paul eene Who is/are personally known to me or Who is/are ersonall kno n to me or as identification. as identification. Notary Public Notary Public Commission No. FF98537 Commission No. FF98537 Elissa M.Holleran Elissa M.Holleran Name of Notarv tvped,printed or stamped Name of Notary typed,printed or stamped ,�".�. •-�. ��I$�t+!{.�10�� '""�� �EI�kH.Pl�IlERAN: / �- 4, ����y�i + �, C�rt��1.�a��PRe�891 � � �.FPpS98p�' p��ij�'�i�lvta���#G'��� 't;��4��`ut��d��'6tA ' �'.�� r �i+a�a;�, � �1�'�1PJiro}�K�l7(SiRfU39iF?C�111�°��r '�•��U1HS�)9�+€�lt'�'�'�1 ��, • uo�i •_ T FORM R405-2014 FL(JRIDA ENERGY EFFICIENCY CODE FOR BUILDING C(:1NSTRUCTION Fiorida Department af Business and ProfessianaF Regulation - Residential Performance Method , � Project Name: 3711 SF Builder Name: LENNAR HOMES i street: 6551 Paden Wheel Street Pem,it otece: i of Zephyrhills City,State,Zip: ,F�, Permit Number ���(/�� Owner� LENNAR HQMES Jurisdiction: 611000 � Design Location: FL,7ampa 1. New construction or existing New{From Plans) 9. Wall Types{3424.9 sqft.) Insulatian Area 2. Single family or multiple family Single-4amiiy a.Frame-Wood,E�eriar R=11.0 '1738,7d ft' b.Concrete Block-int Insul,Exterior R=4 1 1487 10 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.n '!99.11 ftZ 4. Number of Bedroams 4 �•�IA R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2130.0 sqft.) Insulation Area a.Under Attic{Vented) R=3�.0 1998.�0 ft' 8. Conditioned floor area abave grade{ft�} 3711 b.Knee Wat1(Vented} R=30.0 t 3200 Sz Conditioned floor area below grade(ftz) 0 c.N/A R= ft' 11 Ducts R ft2 7 Windows{358.9 sqft.} �escripfion Area a.Sup:1st Ftaor,Ret:1st Floor,AN:ist Ftaor 8 525 a. U-Factor: Dbl,U=0.56 133.00 ft2 b.Sup. Attic, Ret:2nd Floor,AH:2nd Floor 6 430 SNGC: SHGC=0.28 , b. U-Factor DbI,U=0.54 119.25 ft2 12.Coaling systems kBtulhr Efficiency SHGC: SHGG=0.31 a.Central Unit 25.2 SEER:16.20 b.Central Unit 25.2 SEER:16.20 c. U-Factar Dbi,U=0.56 106.67 ft' SHGC: SHGC=0.32 _ 13.Heating systems kBtu/hr Efficiency d. U-Factor� N/A ftz a.Electric Heat Pump 21.8 HSPF:9.00 SHGC: b.Elactric Heat Pump 21.8 HSPF:9.ad Area Weighted Average Overhang Depth: 2.938 ft. � Area Weighted Average SHGC: 0.302 14 Hot water systems 8. Floor Types (1986.0 sqft.) Insulation Area a.Elect�ic Cap:40 gallons � a.Slab-On-Grade Ed e lnsulation R=0.0 1713.00 ft' EF 0.950 9 b. Consenration features b.Floar over Garage R=1'(.0 273.00 ft' None c.N/A R= ft2 15.Credits Pstat � Total Proposed Modified Loads: 97.04 pASS Glass/Floor Area: 0.097 Total Baseline Loads: 98.86 � � i hereby certify that the pians and specifications cavered by Review of the plans and �"�I�ST,q� this calcutafion are in cornp(iance with the Fiorida Energy specificatians covered by this �� , `: �.�t��,, i Code. calculation indica#es compliance ��,���'''s� �-=��:�. �. i with the Florida Energy Code. � � °�'"�''`�;�``k•� �a�e �lo��r`c1� � �f�#�{�.,,, ,� � ; PREPARED BY. Before constructian is completed ,w��,.�"��� '"+ �'�„� � DATE: this building will be inspected for Lry. �'�'�;�. ; .� compliance with Section 553.908 ��`�'� s � I hereby certify that this building,as designed, is in compliance Florida Stetutes. #,�, i �.�, � with fhe Florida Energy Cade. '��J ��D"y�,r�`�� i OWNER/AGENT: BUILDING OFFICI L. t'� RATE: DATE: � - Compliance requi�es certification by the air handler unit manufacturer that the air handler enclasure qualifies as ' certified factory-seated in accordance with R403.2.2.1. � -Compliance requires an Air Barrier and insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage ' tesE report in accordance w9th R402.4.1.2, - � 12l30/2016 2:05 PM EnergyGaugeO USA-FlaRes2014 Section R4�5.4 1 Compliant Software Page 1 of 5 , I { I � ; FORM R405-2Q14 FLORIDA ENERGY EFFICIENCY CODE FOR BUlLDING CONSTRUCTION Florida Department of Business and Professiona[ Regu}ation - Residential Performance Method " _ � Project Name: 3711 SF Builder Name: LENNAR HOMES � street: 6551 Paden Wheel Street Pem,it o�ice: City of Zephyrhills ' City,State,Zip. ,FG, Permit tVumber: ' Owne�• LENNAR HOMES Jurisdiction: 61I000 Qesig��ocation: FL,Tampa 1 New canstruction or existing New(From Plans) 9. Wall Types(3424.9 sqft.) Insulation Area 2. Single family or rnultipie family Singte-fami{y a.Frame-Wood,Exterior R=11.0 1738.74 fE� b.Concrete Block-int insul,Exterior R=4 1 1487.10 ftz 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.� 199.11 ft' 4 F3umber of Bedroams 4 d.NIA �_ �� 5. Is this a worst case? 10.Ceiling Types (2130.0 sqft.) Insulation Area YeS a.Under Attic(Vented) R=30.0 1998.00 ft' 6. Canditioned floor area abavs grade(ft� 3?11 b.Knee Wa11(Vented) R=30.0 132.00 ft2 Conditioned flaor area below grade(ftz) 0 c.N/A R= ft' � 11.Ducts R ftz 7. Windows(358.9 sqft,) Description Area a.Sup:1st Flaor,Refi 1st F1oar,AH:1st F400r 6 525 a. U-Factor: Dbl,U=0.56 133.00 ftx b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 43Q SHGC: SNGC=0.2& b. U-�actor Dbl,U=d.54 ��g,2�{�z 12.Cooling systems kBtulttr ��ciency SHGC: SHGC=0.31 a.Central Unit 25,2 SEER:1620 b.Central Unit 25.2 SEER:16.20 c. U-Factor DbS,U=0.56 106.67 ft2 • SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor� N/A ft2 a.Electric Heat Pump 21.8 HSPF:9.00 � SNGC: b.Electric Hea#Pump 21.8 HSPF:9.00 j Area Weighted Average Overhang Depth: 2.938 ft. i Area Weighted Average SHGC: b.302 14 Hot water systems a.Electric Cap:44 gallons � 8. Floor 7ypes (1986.0 sqft.) insulation Area � EF 0.950 a.Slab-On-Grade Edge Insulation R=0.0 1713.00 ftx b. Conservation features b.Floar over Garage R=11.0 273.40 ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: p.097 Total Proposed Modified Loads. 97.04 pASS Total Baseline Loads: 98.86 ; ; 1 hereby certify that the pians and specifications covered by Review of the plans and ��'�:�?'��� ; this ca{cuiation are in compiiance with the Fiorida Energy specificstions covered by this � ;_ '" ��;� C)C�; ' Code. calculation indicates compliance ���r,��;'`'�, -__.;�**�1���, ���� �Wl��t, with the Florida Energy Code. �+. �rr{,.�•.�'.`r,,.;�:_.�:,�~�:-'�„:G , PREPARED BY: �Z Before construction is completed w. , `'""Y "`tt�µ � DATE: this building will be inspected for t�,ry ����` " �� � compliance wifh�ectian 553.9Q8 *' Y'�{- '� I hereby certify that this building, as designed, is in compliance Flarida Statutes. �,, �� with the Flarida Energy Code. ��T.)�y'E"t� OWNER/AGENT: BUILDING OFFICIA . '�'` ` ' � DATE: QATE: ' , - Compliance requires certiflcation by the air handler unit manufacturer that the air handler enclosure qualiFes as i certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accardance inrith R402.4.1.2. - 12/30f2016 2:05 PM EnergyGauge�USA-FlaRes2d14 Section R405.4.1 Compliant Software Page 1 of 5 � 7 . FORM R405-2014 r FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential PerFormance Method � Project Name. 3711 SF Builder Name: LENNAR HOMES I street: 6551 Paden Wheel Street Permit o�ice: City of Zephyrhills City,State,Zip: ,FL, Permit Number Owner• LENNAR HOMES Jurisdiction: 6110�0 � Design Location: FL,Tampa 1. New construction or existing New(From Plans) 9. Wall Types(3424.9 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1738.70 ft' b.Concrete Block-Int Insul,Exterior R=4 1 1487.10 ft' ' 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 199.11 ft' 4 Number of Bedrooms 4 d.N/A R= ft' 5. Is this a worst case? Yes 10.Ceiling Types (2130.0 sqft.) Insulation Area � a.Under Attic(Vented) R=30.0 1998.00 ft � 6. Conditioned floor area above grade(ftz) 3711 b.Knee Wall(Vented) R=30.0 132.00 ft� Conditioned floor area below grade(ftZ) 0 c.N/A R= ft� 11 Ducts R ft= 7. Windows(358.9 sqft.) Description Area a.Sup: 1st Floor,Ret:1st Floor,AH:1st Floor 6 525 a. U-Factor Dbl,U=0.56 133.00.ftz b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 430 SHGC: SHGC=0.28 b. U-Factor Dbl,U=0.54 119.25 ft= 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.31 a.Central Unit 25.2 SEER:16.20 b.Central Unit 25.2 SEER:16.20 c. U-Factor Dbl,U=0.56 106.67 ftZ SHGC: SHGC=0.32 13.Heating systems kBtu/hr E�ciency d. U-Factor• N/A ft2 a.Electric Heat Pump 21.8 HSPF:9.00 i SHGC: b.Electric Heat Pump 21.8 HSPF:9.00 Area Weighted Average Overhang Depth: 2.938 ft. Area Weighted Average SHGC- 0.302 14 Hot water systems i S. Floor Types (1986.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF.0.950 a.Slab-On-Grade Edge Insulation R=0.0 1713.00 ftz b. Conservation features b.Floor over Garage R=11.0 273.00 ft' None c.N/A R= ft2 15.Credits Pstat � Glass/Floor Area: 0.097 Total Proposed Modified Loads: 97.04 � A C C Total Baseline Loads: 98.86 �1���� I�i I hereby certify that the plans and specifications covered by Review of the plans and �'�:�7'<q?. I this calculation are in compliance with the Florida Energy specifications covered by this �•� ,� �_.��CY,�,�, 'i Code. calculation indicates compliance �'��,,,°' '_'-�=,:`�.. +fi. �. ::__,.� ��'c'` /, with the Florida Energy Code. � rr�ar�'.'��••.r;:�a�,:,�,'��,,,,ti O PREPARED BY' �ave ����Yc Before construction is completed w r '`" � ; � . .�"��,�. ..... _�; DATE: this building will be inspected for try: , i� .• compliance with Section 553.908 �. �'� � �, , I hereby certify that this building,as designed, is in compliance Florida Statutes. ��,C ._ � y��� with the Florida Energy Code. dD�yE`� , i OWNER/AGENT. BUILDING OFFICIAL: DATE: DATE. i - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as ! certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage ' test report in accordance with R402.4.1.2. 12/30/2016 2:05 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 , � FORM R405-2Q14 PRf3JECT � Titie: 3711 SF Bedrooms: 4 Address Type: Stteet Address � Building Type: User Conditioned Area: 3711 lot# Qwner LENNAR HOMES 7otal Staries: 2 Block/SubDivision: I #af Units: 1 Warst Case: Yes PlatBoak: I Builder Name: LENNAR HOMES Rotate Angle: 225 Street: Permit Office: Cross Ventilation: No County• Pasco � Jurisdiction: Whole Eiouse Fan: No City,State,Zip; Family Type: Single-family FL, NewlExisting: New{From Plansj , Comment: ADS CLiMATE j IECG Design Temp !nt Qesign Temp FksaYing Desig� daily Temp V Design Location TMY Site Zone 97.5% 2.5°!o Winter Summer Degree Qays (ulaisture Range FL„Tampa FL_TRMPA WTERNATt 2 38 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 61ock1 179 3 15930.9 = 2 Block2 1998 15984 ' SPACES i _ Number Narne Area Volume Kitcherr Occupants Bedraoms infil!D Finished Cooled Hested � 1 1st Floar 1713 15930.9 Yes 2 0 1 Yes Yes Yes I 2 2nd Floor 1998 15984 tVo 5 4 1 Yes Yes Yes � F�ooRs � # Floor Type Space Perimeter Perimeter R-Value Area Joist Ft-Value 7ile Wood Carpet ' 1 Floor over Garage 2nd Floor �_ _.._ 273 ftZ 'S'[ d 0 1 ; i 2 Slab-On-Grade Edge Insulatio ist Floor 162.2 ft 0 1713 ft' ___ 0.3 0 0.7 : i R�OF ' j / Roof Gabie Roof Sotar SA Emitt Emift Deck Pi#ch � V # 7ype Materials Area Area Color Absor Tes#ed Tested Insul. (deg) ' 1 Hip Composition shingles 2235 ft2 0 ftZ Medium 0.85 N 0.9 No 0 26.6 � ATTIG � V # Type Ventilation Vent Ratio(1 in) Area RBS iRCC i Full attic Vented 300 1998 ft' N N , � i 12/30/2016 2:05 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 CEILING # Ceiling Type Space, ' � R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 30 1998 ft2 0.1 Wood 2 Knee Wall(Vented) 2nd Floor 30 132 ftz 0.11 Wood WALLS Adjacent �Spa� Cavity Width Height Sheathing Framing Solar Below 1 N=>SW Exterior Concrete Block-Int Insul 1st Floor 4 1 21 2 9 4 197.6 ft2 0 0 0.6 0 � 2 S=>NE Exterior Concrete Block-Int Insul ist Floor 4.1 50 0 9 4 466.7 ft' 0 0 0.6 0 3 E=>NW Exterior Concrete Block-Int Insul ist Floor 4.1 40 4 9 4 376.4 ft= 0 0 0.6 0 4 W=>SE Exterior Concrete Block-Int Insul 1st Floor 4 1 40 4 9 4 376.4 ft2 0 0.6 0 _5 N=>SW Garage Frame-Wood 1st Floor 11 21 4 9 4 199.1 ft2 0.23 0.01 0 6 N=>SW Exterior Frame-Wood 2nd Floor 11 50 8 40�.0 ftZ 0.23 0.6 0 7 S=>NE Exterior Frame-Wood 2nd Floor 11 50 8 400.0 ft= 0.23 0.6 0 S E=>NW Exterior Frame-Wood 2nd Floor 11 58 8 8 469.3 ftz 0.23 0.6 0 9 W=>SE Exterior Frame-Wood 2nd Floor 11 58 8 8 469.3 ft2 023 0.6 0 � _10 N=>SW Exterior Concrete Block-Int Insul 1 st Floor 4.0999 7 6 9 4 70.0 ftZ 0 0.600000 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In I 1 N=>SW Insulated 1st Floor None .2 3 6 8 20 ftZ I 2 N=>SW Wood 1st Floor None .4 2 8 6 8 17.8 ft2 I ' I WINDOWS Orientation shown is the entered orientation(_>)chan ed to Worst Case. � � Wall Overhang # Omt �ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>SW 1 Metal Low-E Double Yes 0.56 0.28 16.0 ft' 1 ft 0 in 10 ft 4 in Drapes/blinds Exterior 5 2 N=>SW 1 Metal Low-E Double Yes 0.56 0.28 23.0 ft2 1 ft 0 in 10 ft 4 in Drapes/blinds Exterior 5 ' 3 S=>NE 2 Metal Low-E Double Yes 0.56 0.32 106J ft� 7 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 ' I 4 S=>NE 2 Metal Low-E Double Yes 0.54 0.31 9.3 ftZ 7 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 '� I 5 E=>NW 3 Metal Low-E Double _ Yes 0.54 0.31 23.0 ft� 1 ft 0 in 10 ft 4 in Drapeslblinds Exterior 5 i 6 W=>SE 4 Metal Low-E Double Yes 0.54 0.31 16.0 ft' 1 ft 0 in 10 ft 4 in Drapes/blinds None 7 N=>SW 6 Metal Low-E Double Yes 0.56 0.28 48.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 8 N=>SW 6 Metal Low-E Double Yes 0.56 0.28 46.0 ft' 1 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 � 9 S=>NE 7 Metal Low-E Double Yes 0.54 0.31 32.0 ft' 1 ft 0 in 0 ft 6 in Drapes/biinds None I'� i 10 S=>NE 7 Metal Low-E Double Yes 0.54 0.31 23.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None � 11 W=>SE 9 Metal Low-E Double Yes 0.54 0.31 16.0 ft' 1 ft 0 in 0 ft 6 in Drapes/blinds None i I � I i 12/30/2016 2:05 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 I FORM R405-2014 . GARAGE # FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation � 1 606 ft2 273 ft2 78.5 ft 9.3 ft 1 . INFILTRATION . ; # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 ' 1 Wholehouse Proposed ACH(50) .000273 2659.6 146.01 274.59 .2523 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.9999 21.8 kBtu/hr 1 sys#1 ' 2 Electric Heat Pump None HSPF:9 21.8 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER. 16.225.2 kBtu/hr 756 cfm �.85 1 sys#1 � 2 Central Unit Split SEER: 16.225.2 kBtu/hr 756 cfm 0.85 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM I FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF � None None ft' I DUCTS II / —Supply— --Retum— Air CFM 25 CFM25 HVAC# ; V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool i 1 1st Floor 6 525 ft2 1st Floor 166 ftZ Default Leakage 1st Floor (Default) (Default) 1 1 ' i 2 Attic 6 430 ft2 2nd Floor 155 ftZ Default Leakage 2nd Floor (Default) (Default) 2 2 , �I 12/30/2016 2:05 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Jan Feb Mar Apr May X Jun Jul Aug Sep Oct Nov Dec Heating Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec ' Venting �Jan �Feb €X�Mar �X�Apr € �May � �Jun ��Jul ��Aug ��Sep �Oct �X Nov ��Dec ' Thermostat Schedule. HERS 2006 Reference Hours , Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 i PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 , PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(VI/D) AM 66 66 66 66 66 68 68 68 68 68 68 68 � PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(V11EH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION , Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 1 -Electric Heat Pump 0% 1 -Central Unit None 0 0 0 2-Electric Heat Pum 0°/a 2-Central Unit I �I 12/30/2016 2:05 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 _ � The lower the EnergyPerFormance Index, the more e�cient the home. � „ FL, 1 New construction or existing New(From Plans) 9. Wail Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1738.70 ft2 b.Cancrete Block-Int Insul,Exterior R=4 1 1487.10 ftZ 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 199.11 ftZ 4 Number of Bedrooms 4 d.N/A R= ft' . 5. Is this a-worst case? 10.Ceiling Types Insulation Area Yes a.Under Attic(Vented) R=30.0 1998.00 ftZ 6. Conditioned floor area(ftZ) 3711 b.Knee Wall(Vented) R=30.0 132.00 ftz , 7 Windows*' Description Area c.N/A R= ftZ a. U-Factor Dbl,U=0.56 133.00 ft2 �� Ducts R ft� , a.Sup: 1st Floor,Ret: 1st Floor,AH: 1st Floor 6 525 SHGC: SHGC=0.28 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 430 b. U-Factor Dbl,U=0.54 119.25 ft= SHGC: SHGC=0.31 12.Cooling systems kBtu/hr Efficiency c. U-Factor• Dbl,U=0.56 106.67 ftZ a.Central Unit 25.2 SEER:16.20 SHGC: SHGC=0.32 b.Central Unit 25.2 SEER:16.20 d. U-Factor N/A ftZ 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 21.8 HSPF:9.00 Area Weighted Average Overhang Depth: 2.938 ft. � b.Electric Heat Pump 21.8 HSPF:9.00 � Area Weighted Average SHGC: 0.302 8. Floor Types Insulation Area 14 Hot water systems , z a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1713.00 ft EF 0.95 b.Floor over Garage R=11.0 273.00 ft' � c.N/A R= ftZ b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building �,��.E�rA Construction through the above energy saving features which will be installed (or exceeded) y,0 �._`�o. � in this home before final inspection. Otherwise, a new EPL Display Card will be completed � kg' '`-' �=;;��.,''{'r,s,, �j 'i6�r.. , y_o s.-, p �". - based on installed Code compliant features. � nu�,.�-,,•.�:,-��r���„ o , ��� ._ �� Builder Signature. Date: 04/10/17 c�° �ff�;:Y' �, # :�.n � Address of New Home: 6 51 Paden Wheel Street City/FL Zip: Zephyrhills,FL33541 '� �,'� � � C���,�g,�. . *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient ' mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For , information about the Florida Building Code, Energy Conservation, contact the Florida Building-Commission's support � staff. , , '`*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 12/30/2016 2:06 PM EnergyGauge�USA-FlaRes2014 -Section R405.4 1 Compliant Software Page 1 of 1 I Buildin Anal $�$ Job: 3711sfADS g Y Date: 12/30/2016 lower floor By: Dave Bayonet Plumbing Heating and Cooling ' • - e o ' � For• Lennar Homes , i - • o e s ' , Location: Indoor: Heating Cooling , Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 34 7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb (°F) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft2 Btuh % of load Walls 5.6 7784 30.5 Glazing 30.2 5892 23.1 Doors 23.5 564 2.2 Ceilings 1.5 158 0.6 ' Floors 3.7 6261 24.5 ' Infiltration 1.8 2875 11.3 Ducts 1973 7.7 ,� Piping 0 0 Humidification 0 0 Ventilation 0 0 �-. Adjustments 0 Total 25506 100.0 • � e �' Component Btuh/ftZ Btuh % of load ' Walls 2.8 3872 19.7 "°" I Glazing 45.9 8965 45.7 Doors 18.4 442 2.3 Ceilings 2.0 210 1.1 � Floors 0 0 0 3 ; Infiltration 0.4 622 3.2 � Ducts 2274 11.6 � Ventilation 0 0 � � Internal gains 3250 16.6 Blower 0 0 �` "� Adjustments 0 i Total 19635 100.0 � j Latent Cooling Load=2691 Btuh j Overall U-value= 0.154 Btuh/ftz-°F � Data entries checked. ,� W1'1 f1tSOft' 201frDec-3013:53:05 �. � g Right-Sude�Universal 2013 13.0.09 RSU05714 Page 1 � H:\LENNAR LOADS13711 sf ADS drawn 2-2tons.rup Calc=MJ8 Front Door faces: N Buildin Anal $�$ Job: 3711sfADS � � Date: 12/30/2016 upper floor By: Dave Bayonet Plumbing Heating and Cooling ' • - s s , For: Lennar Homes , O - e o o • Location: Indoor: Heating Cooling ' Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: � Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 0 z o Component Btuh/ft Btuh /o of load ' Walls 3.8 6124 32.3 ' Glazing 30.2 4991 26.3 ' Doors. 0 0 0 � Ceilings 1.3 2507 13.2 � Floors 2.0 2 0.0 , Infiltration 1.8 3175 16.8 �, D ucts 2143 11.3 , Piping 0 0 �, ' Humidification 0 0 � Ventilation 0 0 Adjustments 0 �" , Total 18942 100.0 se � i � ' Component Btuh/ftZ Btuh % of load o,.„ � Walls 2.7 4421 21.4 � ' Glazing 55.5 9170 44.3 , Doors 0 0 0 ' Ceilings 1.7 3466 16.7 Floors 0.8 1 0.0 i Infiltration 0.4 687 3.3 Ducts 2459 11.9 ' m" ' Ventilation 0 0 Internal gains 500 2.4 �, Blower 0 0 � Adjustments 0 ' Total 20703 100.0 � � Latent Cooling Load= 1859 Btuh Overall U-value= 0.092 Btuh/ftz-°F Data entries checked. .` WI'1 �1tS0'�` 2016-Dec-3013:53:05 ,..� 9 Right-Suite�Universal 2013 13.0.09 RSU05714 Page 2 � H:\LENNAR LOADS\3711 sf ADS drawn 2-2tons.rup Calc=MJB Front Door faces: N Project Summary Job: 3711 sfADS Date: 12/30/2016 �OW@I'�001" - By: Dave . Bayonet Plumbing Heating and Cooling ' • - • • For: Lennar Homes N otes. � � - • s e Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 39 °F Design TD 16 °F , Daily range L Relative humidity 50 % Moisture difference 55 gr/Ib Heating Summary � Sensible Cooling Equipment Load Sizing � Structure 23534 Btuh Structure 17361 Btuh � Ducts 1973 Btuh Ducts 2274 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25506 Btuh Use manufacturer's data y Rate/swing multiplier 1 00 Inflltl'etlon Equipment sensible load 19635 Btuh Method Simplified Latent Cooling Equipment Load Sizing � Construction quality Semi-tight Fireplaces 0 Structure 2289 Btuh ' Ducts 402 Btuh � Heating Cooling Central vent (0 cfm) 0 Btuh Area(ftZ) 1713 1713 Equipment latent load 2691 Btuh ; Volume(ft') 17699 17699 Air changes/hour 0.23 0.12 Equipment total load 22326 Btuh � Equiv.AVF (cfm) 67 35 Req. total capacity at 0.85 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox � Trade 14HPX SERIES Trade 14HPX SERIES , Model 14HPX-024-230-18 Cond 14HPX-024230-18 AHRI ref 5186808 Coil CBX27UH-024230'++TDR i AHRI ref 5186808 Efficiency 9 HSPF Efficiency 13.7 EER, 16.2 SEER Heating input Sensible cooling 21420 Btuh ! Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh ' Temperature rise 25 �F Total cooling 25200 Btuh � � Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.031 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.88 Calculations a roved b ACCA to meet all re uirements of Manual J 8th Ed. � PP Y q �, WI'1 �'ItSO'�' 201frDec-3013:53:05 9 Right-Suite�Universal 2013 13.0.09 RSU05714 Page 1 '�A H:\LENNAR LOADS\3711 sf ADS drawn 2-2tons.rup Calc=MJB Front Doorfaces: N Pro ect Summa Job: 3711 sfADS 1 � Date: 12130l2016 upper floor By: Dave Bayonet Plumbing Heating and Cooling ' • - � a For Lennar Homes Notes: , ! - � s s . I Weather� Tampa International AP, FL, US ' Winter Design Conditions Summer Design Conditions - , Outside db 31 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 39 °F Design TD 16 °F Daily range � Relative humidity 50 % Moisture difference 55 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing ; Structure 16799 Btuh Structure 18244 Btuh Ducts 2143 Btuh Ducts 2459 Btuh � Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 18942 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Inflltt'atlOn Equipment sensible load 20703 Btuh Method simplified Latent Cooling Equipment Load Sizing � Construction quality Semrtight � Fireplaces 0 Structure 1424 Btuh ; Ducts 435 Btuh ' Heating Cooling Central vent (0 cfm) 0 Btuh Area (ftz) 1998 1998 Equipment latent load 1859 Btuh � Volume(ft') 15986 15986 Air changes/hour 0.28 0.14 Equipment total load 22563 Btuh Equiv.AVF(cfm) 74 38 Req. total capacity at 0.85 SHR 2.0 ton - Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox ; Trade 14HPX SERIES Trade _ 14HPX SERIES Model 14HPX-024-230-18 Cond 14HPX-024230-18 AHRI ref 5186808 Coil CBX27UH-024230*++TDR AHRI ref 5186808 � Efficiency 9 HSPF Efficiency 13.7 EER, 16.2 SEER Heating mput Sensible cooling 21420 Btuh ' Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh i Temperature rise 25 �F Total cooling 25200 Btuh � Actual air flow 800 cfm Actual air flow 800 cfm , Air flow factor ' 0.042 cfm/Btuh Air flow factor 0.039 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.92 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Dec-30 13:53:05 �, '�' wrightsoft" Right-Suite�Universal 2013 13.0.09 RSU05714 Page 2 '��` H:\LENNAR LOADS\3711 sf ADS drawn 2-2tons.rup Calc=MJ8 Front Door faces: N 1 , • Manual S Compliance Report Job: 3711 sfADS - - Date: 12l30/2016 lowerfloor By: Dave Bayonet Plumbing Heating and Cooling ' � - • � For. Lennar Homes • • • • • � Design Conditions ' - Outdoor design DB. 91.3°F Sensible gain: 19635 Btuh Entering coil DB 75.7°F , Outdoor design WB. 77.3°F Latent gain: 2691 Btuh Entering coil WB• 62.9°F Indoor design DB. 75.0°F Total gain: 22326 Btuh Indoor RH. 50% Estimated airflow� 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SpIitASHP Manufacturer: Lennox Model: 14HPX-024230-18+CBX27UH-024230'`++TDR Actual airflow: 800 cfm Sensible capacity: 21420 Btuh 109% of load � , Latent capacity: 3780 Btuh 140% of load � Total capacity� 25200 Btuh 113% of load SHR. 85% o • • � � Design Conditions Outdoor design DB. 30.8°F Heat loss 25506 Btuh Entering coil DB� 69.6°F ; Indoor design DB: 70.0°F i I Manufacturer's Performance Data at Actual Design Conditions � Equipmenttype: SpIitASHP � Manufacturer: Lennox Model: 14HPX-024230-18+CBX27UH-024230"++TDR Actual airflow: 800 cfm Output capacity: 21800 Btuh 85% of load Capacity balance: 41 °F �� Supplemental heat required: 3706 Btuh Economic balance: -99 °F i Backup equipment type: Elec strip j Manufacturer� Model: � Actual airflow: 800 cfm ! Output capacity: 7.9 kW 105% of load Temp. rise: 50 °F , The above equipment was selected in accordance with ACCA Manual S. , ,c wrinhtsoft` 2016-Dec-3013:53:05 � � 7 Right-Sude�Universal 2013 13.0.09 RSU05714 Page 1 �� H:\LENNAR LOADS\3711 sf ADS drawn 2-2tons.rup Calc=MJB Front Door faces: N I � ' � , . . Manual S Compliance Report Job: 3711 sfADS Date: 12/30/2016 upper floor By: Dave Bayonet Plumbing Heating and Cooling ' s - • o For: Lennar Homes e o • • • Design Conditions Outdoor design DB� 91.3°F Sensible gain: 20703 Btuh Entering coil DB 75.7°F Outdoor design WB: 77.3°F Latent gain: 1859 Btuh Entering coil WB� 62.9°F Indoor design DB• 75.0°F Total gain: 22563 Btuh Indoor RH 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions , Equipment type: SpIitASHP Manufacturer: Lennox Model: 14HPX-024230-18+CBX27UH-024-230*++TDR Actual airtlow� 800 cfm Sensible capacity: 21420 Btuh 103% of load � Latent capacity: 3780 Btuh 203% of load , Total capacity� 25200 Btuh 112% of load SHR. 85% • . . , Design Conditions Outdoor design DB. 30.8°F Heat loss: 18942 Btuh Entering coil DB. 69.6°F � Indoor design DB� 70.0°F ; i Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer Lennox Model: 14HPX-024-230-18+CBX27UH-024230'`++TDR Actual airflow: 800 cfm � Output capacity: 21800 Btuh 115% of load Capacity balance: 35 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F ' Backup equipment type: Elec strip Manufacturer Model: Actual airflow: 800 cfm � Output capacity: 6.0 kW 108% of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. ,�, wri htsoft� 2016-Dec-3013:53:05 � � 9 Right-Suite�Universal 2013 13.0.09 RSU05714 Page 2 �'� H:\LENNAR LOADS\3711 sf ADS drawn 2-2tons.rup Calc=MJ8 Front Door faces: N � Lennar Homes-6551 Paden Wheel St-4,646 sq ft o umn SQ. FEET PRICE MAIN OR LIVING: 4,646 $ 106.36 OTHER AREA UNDER ROOF: - - $ 88.00 OTHER: - $ - ' VALUATION $ - 494,148.56 FEE SHEET $ 1,673.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,786.46 ELECTRICAL: $ 376.43 PLUMBING: $ 250.95 MECHANICAL: $ 175.67 SUB-TOTAL $ 2,589.50 TOTAL $ 2,589.50 SEWER: na � WATER: na I IRRIGATION: $ - � TOTAL: $ - , WATER METER: na IRRIGATION METER $ - � FIRE DEPARTMENT FEES ' PLANS TOTAL: na ! INSPECTION TOTAL: � PERMIT TOTAL j TOTAL: $ - � PUBLIC SAFETY IMPACT FEES � POLICE $ 254.00 , FIRE $ 273.00 ' 5% $ 26.35 I TOTAL: $ 553.35 j I SUB-TOTAL $ 3,142.85 I, PARK IMPACT FEES $ 769.56 i SIF'S: $ 4,828.00 � 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 12,420.69 � 6551 Paden Wheel o umn SQ. FEET PRICE UNDER ROOF: 4,646 $ 106.36 OTHER: - $ - VALUATION $ 494,148.56 FEE SHEET $ 1,673.00 ADDRESS $ .00 DRIVEWAY $ . 0 BUILDING: $ 1,826.46 ELECTRICAL: $ 376.43 PLUMBING: $ 250.95 MECHANICAL: $ 175.67 SUB-TOTAL $ 2,629.50 TOTAL $ 2,629.50 S EW ER: WATER: � IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER I FIRE DEPARTMENT FEES ' PLANS TOTAL: ! INSPECTION TOTAL: � PERMIT TOTAL , TOTAL: $ - � PUBLIC SAFETY IMPACT FEES � POLICE $ 254.00 � FIRE $ 273.00 � 5% $ 26.35 ' TOTAL: $ 553.35 , S U B-TOTAL $ 3,182.85 � PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ I '� ��2�' �°� � Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. ' 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. ' 4. Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. 9. No electric,plumbing,mechanical, or framing shall be covered without an inspection and � � approval first. � � 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). , 11. Appliances shall not be installed in a location where subject to mechanical damage unless � protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. ' 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 ' 14. Return air in all bedrooms. F.B.C. M1620.4 � 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. , I 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. ' I 17. All means of egress are to be in accordance with R311 of the F.B.C. - ' 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. ', 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating ' or appliances or an attached garage. They shall be installed in accordance with the F.B.C. � 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all �� underground plumbing and electric. �� 22. A112008 N.E.C. Codes will be enforced. �� 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 � 22. In accordance with the Land Development Code, lots shall be sodded before final at least 10 � feet around the structure. � F.F.E.-Finished Floor Elevation F.B.C-Florida Building Code 5�'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008) � , SKETCH ONLY SEC. 05 , TWP. 26 S, RNG. 21 E_ PLOT PLAN NOT A BOUNDARY SURVEY LOT 8, BLOCK 4 BEARING BASIS: SILVERADO RANCH SUBDIVISION NORTH BOUNDARY OF SE�/e OF 05-26-21 BEING N 89'25'07" E PHASES 2, 3 8L �}- THIS SURVEY IS SUBJECT TO ANY FACTS THAT PASCO COUNTY, FLORIDA. � MAY BE DISCLOSED BY A FULL AND ACCURATE ON LOT AREA CALCULATIOMS TITLE SEARCH. ALSO SUBJECT TO SETBACKS, LOT = 10495.30 gQ, �', EASEMENTS AND RESTRICl10NS OF RECORD. LIVING AREA = 1773 SQ. F1'. roi UNDERGROUND FOOTER, STEM WALL, AND ENTRY =3S SQ. FT. �� UNDERGROUND UTILITIES ARE NOT LOCATED OR ' GARAGE = 606 SQ. FT. SHOWN. COVfREO LANAI = 294 SQ. FT. PAT10 =�A SQ. FT. W DO NOT SCALE THIS PRINT. DIMENSIONS AND CONC. DRIVE = 1167 SQ. FT. Q NOTES TAKE PREFERENCE. A/C & CONC PAD = 24 SQ. FT. � DESCRIPTION NOT CONTAINING PLAT BOOK AND PRIVATE SIDEWALK = 3 SQ. FT. IMPERVIOUS = 37 q PAGE INDICATES THAT PLAT IS IN PRELIMINARY STAGE AND IS SUBJECT TO = 3842 SQ. FT. CHANGE AND/OR REVISION. SOD = 6653 SQ. FT. O CERTAIN DATA SHOWN HEREON BASED ON OFFLOTAREACALCUL.ATIONS • � ENGINEERING PLANS PROVIDED BY CLIENT. RIGHT OF WAY =_ 523•79 SQ. FT. PCP(P) DRIVE APRON = 154 SQ. FT. ���5 STRUCTURE 11ES SHOWN HEREON DENOTES PUBLIC SIDEWALK =?�3 SQ. FT. POINT MEASUREMENT FROM FORM BOARDS/FOUNDATION' SOD = 157 SQ. FT. o� ' TO PROPERTY LINE. �o• . TOTAI.S `` ' , AREA -_ „0,9.o9s4. �. � .o��. � PADEN 1NHEEL _ DRIVEWAY = �32� SQ. �. �� � STREET SIDEWALK = 216 SQ. F1'. " 2 • SOD = 6810 SQ. FT. � ;._ ; ��YC�. ' (R/W VARIES) (TRACT L) PRELIiWINARY DRAWING: , THIS PLAN IS FOR PERMITTING PURPOSES ��06 95� � ~ ONLY, NOT FOR CONSTRUC17aN. VERIFY '• ^'- j ��' ' .^S 88°3J��27�� E ALL DIMENSIONS BEFpRE ANY CONSTRUCTION. '-..`" •�Cj�o „ . ` 6.0`�J� LEGEIdD: / + :'�`;• . '`� �`. . . :�_,..,�,_ _^f * f-�= PROPOSED DRAINAGE FLOW ':soo,:. :. _� r'o�2 (00.00) = PROPOSED GRADE '� � � �_ . J ; E-00.00 = EXISTING GRADE NN �� �•_ •y�•°-� - N• } LOT 9 � �;:y�,: ' ' ' \ BLOCK 4 0� � '� • J ' ^�� ,_�'. �"�:• 10.83' i � .f.J. �� _N. 7O- '. ,a �. � . . eO��^ �3, I� �� � � pRQpOSfO `n � I � f�fV�� p�N � o . �� qRAC e � i `�s• �0 e�fFr � LOT 7 (to8.00')- �•2g� �'• @���k8 r�oe BIOCK 4 � �, 5p`o,¢ \ 3�J \ O � ' : /'� � p 4200' o �f.... 29.32' �t o ..... ... . .'�,N "� . N \ CONUNEAlION � � p � �_: � 6S 38 46'• w ry: - . � i � • �: � M ' �9 22� • a' o � . � N �/ �\ � ' NOTES: N ��N� � ���, � LOT GRADING 7YPE = B � \ .� � � • PROPOSED PAD ELEVATION = 108.3' rn �.O.. N 88 35�27 W r�o� FRONT SETBACK = 20 or 22' � TRW.ARCANp �� 34.67� 'so. SIDE SETHACK = 7.5' o+ CONSERVATION \ � J REAR SETHACK = 75' � AREA � 1RACT J � . � DRAINAGE AREA ' -� CONSERVATION� PRO POSED: Y \ uNE LOWEST FLOOR ELEVATIONS:i � m DESCRiPTIO�l: LIVING AREA: 109.00' ' `i LOT 8, BLOCK 4, MAP OR PLAT ENTITLED "SILVERADO RANCH SUBDIVISION PHASES 2, GARAGE AREA: � , N 3 & 4", AS RECORDED IN PLAT BOOK 73, PAGES 59 THROUGH 65, OF THE PUBLIC ELEVATIONS REFERENCED TO � RECORDS OF PASCb COUNTY, FLORIDA. NORTH AMERICAN VERTICAL = CURVE RADIUS ARC CHORD BEARING DELTA DATUM OF 1988_ MEAN SEA Z C170 60.00' 38.40' 37.75' S 7075'20" E 36'40'14" ■ - 10' UTILITY EASEMENT LEVEL= 00.00 FT. � g APPARENT FLOOD HAZARD ZONE: '�X" COMMUNITY PANEL N0. 120230 0455 D EFFECTIVE DATE: 09/30/1992 � LEGEND: > (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT pATA, �= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= � CONCRETE SLAB, CH= CHOftD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMEN7, ESM'T= EASEMENT, / F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED � PIPE, LFE= LOWEST Fl.00R ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK. PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT a REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & D15K, T6M= TEMPORARY BENCHMARK, � U P= UTILITY POLE, W F= WOOD FENCE. R = RADIAL � JOHN R.BEACH&ASSOCIATES,IIVC. Drawn By. SMS Square Feet: 10495.30 t LENNAR HOMES a � W SURVEY.ORS AND MAPPERS Checked By. � � 911 WEST ST. PETERSBURG DRIVE JRB in ONE OLDSMAR, FLORIDA 34677 y wAY (813) 854-1276 FAX (813) 855-8370 Scale: �^=30' � v3�3o��� 0 •� NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 3 29 17 ACS 'v THE ORIGINAL RAISED SEAL OF A FLORIDA HN BEACH 1E � LICENSED SURVEYOR AND MAPPER FLORIDA G. LAND SURVEYOR No_ 2984 #4493 � / Revisions: � � ___._.._�- ,,.- - r. �_....._-.-__ '.� � ���, �, �, - ,1.,,,-�., , - _ _. - � �=,o9.�Q t� , -' L0�[ 1 ,. � Ff=�09.90 Gj PAD=109.0 ',� ' � , 5- l.17T1 � �j1��� rtr� TYPE A �,�� 5 iD < '� a �_ c� Oc�' 1_ �O �`\ �� � , �� �1 ���. � �o � � � `� � . �` CO , , aj. .G '� •. ^, �, ^ � 1J �,� ' FF=1�� � �, 1 ' o-,� 'S� �+�k ' :� � , �- • " � -t- A J � � ` — 'r �e.a �F D� 9 2 ' �� �f � P�o;o_� „o. � � � o�. 1c �` o ` �- 9 y � A w , O _'� i �p ` � •a' �H~ °�Y � PAS��� , � � �\ tYPE : �l � � 1- �r11Q-34 � �, ,�� ,r u + � � �r p• '� 13 4� � `�`� U' j \''�� ,a`' � , �` \ `'v �?�'lO �� �. .� � o p�p�109.6 �, �� �'� � � i � � Q� =1 �' ��J -- -�pE A �� � � -� ,r 'e . �ti � ti '1 � �. C ,C , �OT '� � � FF=�10.60 , 1 � � '� �. �• j � °� ts- �-U', � .50 �. �j�'� 4 10 B .� t`\` .,. pp,��A �.-110ti84 QA��09.9 � �+ "�Q �n � ' �to� C�' . , 0� A � `1,. '�- � � i` 6, �t'•ti�6 s�'t`;yr 4� <„�� � � F1.0��Oft. �z. r4 J�/ �� 5 , ` �'\ FAD=��A� �'PE� �'S ',,,\.,� .'e0 �� o�t J ` -'�' C? P�" � � �� o� ° ,, �� �' '' � � ��, `„ � pE e .c'` ' � n •�,' �'y `2'jR 7�j`�� '�'_� +1 2Q• 6 �s� \ < , . \iC � 'J�•Y �� L ��'1'68-�'� � (+ '��15'6� ,Z? �� , 6 �,y 1 � � �^ w� �..7_�,`' G��. Q.^ �ti r-i-� � � �. { � \\� q t? ' .. O r �lv � ^T__�_- ' yt,MEl'�j! .'`;C"����� �" '�� '� ��• Q�' 6 i - ' °'�s i o� � �-. � ,�C �a .,� �'�� �` � �a' � =�^ � ,,� n ��� ��$ �° 2d ,= �°' �LO�C t�;�'�(�,.}T �' °^ � tiv`O� '-��� ,t1O �f� s!'`�:,�..�,� �„ ..''�>'o ' �`. � .�`\ c °�' ���,�`� � � ' PA�L �L,,c-' - � � r "'' pQ � �"�-.�.� '� �p-�'„'' °: �,� -� �� � ,.T {�� s,e'; ��� - r'v '.��,�"-� _� � � ° �?�� �„ � ..� — �i p � '�^� ^� � fl$`��_`� "� �^,� . , ,- Y� ' ��P`� �„(�'.` �'^ ' $ pRAINAGE EASEMENT `� � ,t,'" ,\.� 1 ��� ` -, .� ,'�`' -�„� "r / FF�Ojg'�� \` � �''~ � ��_``"�. (� ...-2Q -"'Ca5' .�'� ;�` � �,t � , E7�tEhr�.---*• 'PAp:109.2 � 1 .,,,,,,""". `' ���`���" -� �.6� � 9 � ' - ---��- tJTtUTY _ ,__ - r^fPE $ �.. ------'"'� ��-���.,,,, c�-r �7oa$Q , S — ' ' � , . .F�_�.�a:io h� ,_ -g� I °�-' �r-. � , �S�o.� V -; --- '� ' , ppp-109-� � .�.�� 4�0 `, ` � `�"`�'' -- ��, � ,�'PE B �` ` ` FF_110.30.� T`f1'E 8 �j� - " 147. � � '=r - 114.50 Lp 3 ` `� e . �� . �c� � V _ - _ Q7�(g8$ , F.110.5� �. f���T 4 PHA'�E$6 ��� 6`� �� c ' • � ; FF= ,�FLOtOz� PA�� 518 FADP��1• � .__-•_- �-� ` � ` ' '�. .� '�� f1- ��t oe ��, t a9 2o T � tr=ti0$ 'tY � -- � , � � �. �4T�g� � T 1 ._PpD.�.�� �� - _` `� �`S 6 4AD,=�d$'3 _ PA�1�1Q8.s SYt;�e ;" - 6A \ � o� r �z'�C? TYPE`8' �ji^(PE e -- ;� ' - � �(� '�� �- • 18'(g�• _' � n-. � �� , ,r '• ,r �-' v• , ` � _ �,,,l.f ^ � - .' ' ' tx• C �S ��.,, _1 ti�' � � i'-' C � �� g0 s' �V ' `T O � "� p,�°c . '\ ��+�' c'• "tY' - ��� , -'` +� � `� �„� �3. ; � � h0�' � ,�C _ -r f„� �'�` 6 �-g is �',9C,r "'s� � _,1 a.'\ -'r- -��' �^7.£rL'r8 .�,-� r r°���' 1 ,�Q ,�'� ,-, 11. -~' �e•Y Q` ^r_z_ .$' -'� � _ ��,e-o�a•C�@$C+7� . �.�„-oSWJ'� ^`"•` "'���t pl�'e:. ` ' ` -� �� . - t'` `� (r�� - • . r, ":r'o�'�'_'�yY� ,�„i-��x �"r K'{�^"� "�� �d- ' � ,r .�- , �Y 'f 6 /���. --e�^'�d�� �"+"�'� LT�� '` ' 7� '^��Y R ' + PI p��j'. ��� / �.�'. .'��g D ed � `� ..... , �� .s' �..�tY I ��st 6.� d � � �"� � �gS��� 6��,��� ` • - !-� • 11' �- + ,Y'�, 0 6- � ?' . r.:t. q. ".,, "'8. J' �i O,Ji Y ; ;g ?. Ga�6 .'/'•�d ��� ~`4��• �g```,,, �+ �d q's T/ .f, o. i� .eA� d,,. V�1ET �`� :�°� ��'� N`' --��`�:;,=—�-� � °'�� - �J��6 s� ` S ER�ATI O N _ �'�.._.�:� �`�--- �a �,�. s ` o: `.�6 _ - ��N R EA P .- � Q� ����R�� �,�°�$. `�� ��� ,��- ,t- __ - _.nti- A A� cor�r� -�, . - - .__-- ' ' _ . ^�7 . o S �..�5 - ��� '. , �� 22� � � _, _... . - � . _,o�.o :_.._--------� --- -- .---_ - ---= - �__:=_------- � �oo�o�w" . . RtJBAi F . g(7 � , ' . '. _ , --•.'��_: . _i�---- _ — _ __�