Loading...
HomeMy WebLinkAbout17-18616 CITY OF ZEPHYRHILLS ,. : 5335-8TH STREET , � ,�' - (sis)�so-oo20 18616 � BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION � LOCATION INFORMATION i` Permit#:18616 Issued: 6/28/2017 Address: 36060 STABLE WILK AVE � Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. / Class of Work: 101-NEW CONST/SFR _ Township: Range: Proposed Use: NOT APPLICABLE � Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 250,052.36 Total Fees: 11,322.69 Subdivision: SILVERADO Amount Paid: 11,322.69 Date Paid: 6/28/2017 Parcel Number: 04-26-21-0070-00200-0110 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 15550 LIGHTWAVE DR Address: 4600 W. CYPRESS ST STE 200 CLEARWATER, FL. 33760 TAMPA, FL 33607 Phone: (727)479-1740 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY HOME 2,351 SQ FT APPLICATION FEES BUILDING FEE 1,039.81 ELECTRICAL FEE 211.73 PL MBING FEE 141.15 MECHANICAL FEE 98.81 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfd 1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 � ti����� �� � � � /l � � � ; � � � Ins� ections Re uired � FO TER 2ND RO GH PLUMB MIS I ULATI N CEILING I FOOTER BOND DUCTS INSULATED SEWER MISC. I ROUGH ELECTRIC LINTEL MISC MISC. � ' 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY � PRE-SLAB SHEATHING MISC. MISC. , CONSTRUCTION POLE FRAME MISC. MISC. j REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the; local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or � first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: , NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that� may be found in the public records of this county, and there may be additional permits required from other governmental ; entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O: NO OCCUPANCY BEFORE C.O. i �� CONTRAC ORS SIGNATURE PERMIT OFFI , RMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER I i I , Crystal Reports Viewer . Page 1 of 1 . . ! � '' '� �Oruup Tree j tS �, �!t C .!i`� 'i,(t0o% .=t�Q�j' CFI;p8T�1L 8&�PktB� I s�,'1�-��n P,aiamelers ! M¢InRepoA�.. . � . . � i . , . _.:_,._....,.. . .. . ._ .._ _ . - ' - --_�.---._ , . . I� I -�� � PASCO COUNTY � - - ' BUILDINGCONSTRUCTION3ERVICES ����a , " 8731 Cltlzens Odtre�-- - - Dete:7/312017' �,�y�, - SUI�e�230 1�JN1�.f Nev±Port Richey,FL 34654 � , �"." ' .727-847-8�27 ' � v ** �lOT A 'PERMIT �`* � Recefpt#: 1696863 i � , - j FEE DESCRIPTION �AdCOUNT COD� UNITS INVO C FEE AMOUNT �AID�RECEIPTtl DATE, Impact Fee Reaidentlal Solid B450-389000 27:88 1279323 �$27:88 527�.98 1688B83 7/d1117' � Wasla Slrrele Famlly TOTALS: 527:88 E27.BB i �Recelct i! Pa d B C eck� CC uth q, Cashler ID �Workslatlon Receiot Date Amt Pald 9686863 �Chack 881852 2B4 BCCCP3BW �07/3712017 527:88 i Total PaymeMa; 327.E8 � , i I' pevor -d eae� E114Ile� LENNAR H�MES 36090 STABCE.WILK AVE 2HILLS SW FYMNT PERMIT11:18615 I Comments: oqze2�qo�oaozaoo��o � i _ ._ - � -- - - ,I \' k 02895856 Lennar Homes,LT,C JPMo�gan Chase Bank N.A. STUB. CHECK NO. ,"881852 ` I �NYo(CE � 90000Q:1010:114 . 1 of� 1 DATE 07/20Z1�7 C0..11�- NUAIBER DdTE PAYMEI�7,'ADYIEE _ - .CROSS. _ UISGOUIVT_ .NET � 1:5224 15224720211.401A35A: 071017 t5224720�11411435 � $2Z:88 $0.00. '1 "- $27:88 � , ' np � �� l I, , v� � � � �� _ 5 �� ��� �,�� �. .,, � . , � �� � ; � , , �� __ � , , , ,. . � � � ��_ . ;� , ,� ,, ,: _ , ,� .. ����" . ; , , � a � , � J ' City of Zephyrhilis FBA 7'ru� Bilim,9.-8144 - — I 6820202 5335'8th SYlteet� $27.88 $Oi00` $27.88 Ze h r1�i11sFL33542 - � � � l � i � http://crystal3�.accela.com/inyreports%a.dapter/XReportmp.aspx?re:.. 7/31/2017 � - ' -- — � -- CITY OF / / / / BUILDIN� ' ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION � � • • - • � '� ADDRESS � DAT���� �, PERMIT�, . 4�=�1 4 ���- THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job w'ill be accepted. ;- .� � . / . , It is unlawfu�for any Carpenter,cantractor,Bui�der,or other persons,to AFTER CORRECTIONS ARE MADE CALL � cover or cause to be covered,any paR of the work with flooring,lath,earth 780-0020 FOR R -INSPECTION � or other material,until the proper inspector has had ample time to approve � the installaGon. , OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR � - � � ' , P'�►��� �QU1V1'Y, FLC}RI1�A � . - - Permit Na. �C3 �fp Qats Pacmifted ��'7 � � 8uilder NamelOwner Name ���-nQ r'" t�''`�'s��Cantrol# ' . ( �Courily Parcei No. t��'�-2�(-p0��^�2.�-Ol� D SubDlv: �! !G{'f�� AddresslLocation ��p�b �1�-v tC' (�5.�t�t�`�'�- � / 'ClassificationtType of Us� �' �� / ' �TRANSPOR7ATION IMPACT FEE Rate: 8q-Ft Unit: 2r v�cS� ' ` �� ;Exempt ❑ Yes ❑ No Now Deferm3ned � ,Impact Fee Amounk $ Zane No. TAZ: � � � �SCHOOL tMPAGT FEE I Account (Q56) Singie-Family Detached Hause Amount $ �-�Q7(v-2.-� , , � (057) Mobile Home ' , (U58) Other Resldentla! � - ��, 123) Colleetfon Fee � � 1 iExempt [�]Yes []�!o � How:Determtned � , � ' iPARKS AND R�CREATIt?N FEE � ;Land Accaunt Land Credit Land`fotat '� • ��Recreation Account Recreatian Credlt Recreatian Total • i . . . . �ZOne � TOTAL AMOUNT $ '7�I f cS,6 I �,Exempt ❑Yes ❑ No How Determined : � 'LtBRARY P�E Land A�count Land Credit Land Tota! -�J � �aciiity Account Facility Credit Facil(ty Totai ' . �� � Exempt ❑Yes ❑ No How Determined Total Amount � ' RESOtlRCE FEB ERU - TOTAI�•AMQUNT ' � .. , , - � . �f I'repared By Checked By � Na CERTtF[cA7E O�OCCUPANCY WtLL BE ISSUED OR FINAL tNSPECTtON PERFORMED UIVTIL THE TOTAL AMOUNI'S LiSTED HAVE , . SEEN PAID AND i RECEIPTEp FOR BY A CENTRAL PERMITTING t�FFiCE OF PASCO GGIUNTY I Aoknowledgament below does not Imply acceptance of concurrenoe,6ut simply recalpt of a capy of this farm,piactng , the buiidtng permit owner on notice of this assessment and fhQ conditlons of payment for same. DATE RECE{V�D BY I R�CEIPT NO. DATE BY _ �-�--.�- � �-.� �:-_.,r.�__.-_�.._� l , ', ' ' • �I"II�I�'I�'����II���I"I�'��I�������'����I'�'I����I'�I��'� � � , • � 2077099197 Rept: 1893844 Ree: 35.5U � � - DS: 0.00 IT: 0.00 � 06/23/2017 eRecording ! I This Instrument Was Prepared , � By And Shoald Be Returned To: PAULA S.0'NEIL,Ph.D.PASCO CLERK 8 COMPTROLLER 06/23/2017 09:46 AM 1 of 4 � I,ee E.Nelson,Esquire OR sK 95�� pG 9g� � Shutts&Bowen LLP 4301 W.Boy Scout Blvd.,Suite 300 Tampa,Florida 33607 � � � � MEMORANDUM OF OPTION TO REPURCHASE • THIS MEMORANDUM OF OPTION TO REPURCHASE (the "Memorandum") is ; made and effective this Z 2-day of �us�z , 2017, by atad between DUNE FL LAND I SUB, LLC, a Delaware limited liability company ("Seller'� and LENNAR HOMES, LLC, a Florida limited liability company("Purchaser"). RECITALS: � WHEREAS, Seller and Purchaser have heretofore entered into a Lot Purchase and Sale j Agreement, with an effective date of July 7, 2015, as amended (collectively, the "Agreement"), for the purchase and sale of property located in Pasco County, Florida, as more particularly described therein,and � WHEREA5, Pursuant to�the Agreement, Purchaser has concurrently herewith, closed its purchase of the following: See Exhibit "A" attached hereto (each individually the "Lot" or collectively the I � "Lots"). , i WHEREAS, Purchaser s purchase of and closing of the Lots is with the i.ntention and for , the purpose of Purchaser's construction thereon of a single family home, and �' WHEREAS, pursuant to Paragraph 21 of the Agreemen�, and pursuant to the terms and : conditions set forth in this Memorandum, Purchaser has given and granted to Seller the option to � repurchase the Lot(s) in the event that Purchaser desires to sell such Lot(s) prior to its construction of a residence thereon, or prior to entering into a written contract to construct a i residence on such Lot(s)for its intended purchaser, � NOW THEREFORE, for and in consideration of the premises hereo�the mutual covenants I herein contained and for other good and valuable considerations,the receipt and sufficiency of all of ' �I which are hereby acknowledged,Seller and Purchaser do hereby covenant and agree as follows: i Section 1. Recitals. The above recitals are true and correct and constitute part of this Memorandum. i ..�-' I - � . OR BK ���� PG ggg � ' , • � 4 at 4 EXHIBIT"A" ' Lots 30 and,31,Block 1, SILVERADO RANCH-SUBDNISION PHASES 2, 3 &=4,_according � to"tlie plat thereof as recorded in Plat Book 73, Page 59 et seq., of the Public Records of Pasco � County,Florida. AND , Lot•11; Block 2,�SIL,VERADO.RANCH SUBDIVISION,PHASES-=2;,-3 &.-4, according to the ,., ., , plat thereof as recorded:in Plaf Book 73,Page 59 et seq.;o,f the Publ'ic Records of Pa'sco County, Flo"rida.--:- - � _ . _ . , AND Lots 7_and S, Block 4,:SILVERADO RANCH SUBDIVISION PHASES 2, 3 &4, according to � tlie plat thereof as recorded in Plat Book 73, Page 59 et seq., of the Public Records of Pasco i County,Florida. �I TPADOCS 21618733128053.0162 � i I I � � i � I � I I 1 ` • . OR BR ���� PG _ ' ' 2 of 4 Section 2. Option. Purchaser does hereby rarify and confirm those provisions of ' Paragraph 21 of the Agreement pursuant to which Purchaser has granted to Seller, and Purchaser does hereby grant to Seller, the option to repurchase any Lot�in the event that Purchaser desires to sell such Lot (a)prior to its construction of a residence thereon, or(b)prior to entering into a written contract to construct a residence on such Lot for its intended pnrchaser(the "Third Party ' Buyer"). Section 3. Term of Option. Purchaser and Seller agree that the option rights described in Section 2 of this Memorandum shall immediately terminate as to each Lot without the necessity of recording a termination hereof in the Public Records of Pasco County, Florida upon the , issuance of building permit from Pasco County, Florida for the residence on such Lot (the ' "Tezmination Date"). For the avoidance of doubt, the Ternunation Date sha1l be established as a matter of public record upon Purchaser's conveyance by deed of the Lot to a third party buyer. ' Section 4. Bindin Effect. The provisions of this Memorandum and Paragraph 21 of the I Agreement shall run with title to each Lot, as the case may be, and shaIl hereafter be binding ' upon Purchaser and its successor and assigns until the Termination Date. ' ' IN WITNESS WHEREOF, the parties hereto have caused this Memorandum of Option to Repurchase to be executed as of the date first written above. WITNESSES: ASSTGNOR: i I DUNE FL LANll I SUB,LLC,a Dela.ware �' limited liability company i /(�Z�`" ^ g � ; Y= Print Name ohn M.Ryan,Manager � � Print Name - , i STATE OF FLOR.IDA ) )ss.. COUNTY OF HILLSBOROUGH ) ; � The foregoing instrument was acknowledged before me this�day of � �, � 2017, by John M. Ryan, as Manager of DUNE FL L�AYD I SUB, LLC, a elaware limited ' liability company on behalf of the company, who (�is personally known to me or (� has produc or identification. - � ' I - � I i I Not y Pnblic My Commission Expires: y���� saar�+��r��'�'Y�� •,��"•, KELLEY REMMEL :��'��': :+: :,: MY COMMISSION�GG 0731T! iw�. :o�: p(PIRES:May 31,2021 �'•�j,oc�o:•`'BOfK1Cd TtItU Noiffiy P,�C�nd�►� I ,�,��•' • i � � � 'ef " • • , OR SK �5�� PG 9�g i r • • 3 of 4 i WITNESSES: ASSIGNEE: , LENNAR HOMES, C, a Florida limited � liability comp , I ; I B � � Pr�nt Name N Its: 1 1,�. �'� Print Name��).. 1�,VG��S1i1CL.GC � I , STATE OF 1' I ) )ss.. COUNTY OF I � The foregoing instrument was acknowledged efore me this�day of , , , 2017 b � L• as �L�. IQ/� 1 �P. '1' of LENNAR � Y AOMES, LLC, a Florida limited lia ilitycompany, on behalf of the company, who is personally known to me or (_) has produced for ' identification. . i (,d.��'�.��. . ; Notary Public ; i i I My Commission Expires: ��� ; � 3 ��� �. ��N�.E � �aotaaY Pvsuc ' , �rAr�oF�oRi �� � I � . �",� . � Ca�FF0992A8 Expires 3/8/2p1� � � I � + I Lennar Homes-36060 Stable Wilk Ave-2351 sq ftsingle famity 1 � ` �� SQ.FEET PRICE /U� 1 . MAIN OR LMNG: 2,351 $ 1Q6.36 yd I _ _ �/l , � OTHER AREA UNDER ROOF_ - $ 88.00 y�, _ � I OTHER: - .$ -- 1S - I - � - , VALUATION $ _ 250,052.3fi. � FEE SHEEf $ . - 941.00 ADDRESS $ - 40.00 DRIVEWAY $ 40.OD - BUILDING: $ 1,039.82 ECECTRICAL: $ 211.73 - - PLUMBING: $ -'141.15 MECHANICAL: $ - 98.81 SU�TOTAL $ 1,491.50 _ TOTAL $ 1,491.50 - SEWER: na - _ WATER: �na - IRRIGATION: $ . � TOTAL: $ _ � WATER METER: na IRRIGATION METER $ _ FIRE DEPARTMENT FEES PLANS TOTAL: � na INSPECTION 7'OTAL:,. PERMIT TOTAL - TOTAL: $ _ PUBLIC_SAFETY IMPACT FEES - POLICE $ 254,00 FIRE $ 273.� 5% $ 26.35 � TOTAL:;S 553.36 SUB-TOTAL _$ - 2,044.85 �PARK IMPACT FEES $ 769,56 - SIFS: $ 4,828.00 100.0%.$ 4,828.00 1.0%_$ 4826 TOTA�: $ 4,876.28 T I F'S: $ 3,63200 _ 99% _$ 3,595.66' 1% $ 36.32 -- ---- --- - TOTAL: $ 11,322:69;--- - - - - - 04-26-21-0070-00200-0110 � Pasco County Property Appraiser Page 1 of 1 , Data Current as Of: Weekly Archive - Saturday, June 24, 2017 Parcel ID 04-26-21-0070-00200-0110 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value � DUNE FL LAND I SUB LLC Ag Land $0 C/O HAWK MANAGEMENT CO LLC Land $25,716 2502 N ROCKY POINT DR STE 1050 Building $0 , ROCKY POINT FL 33607-5995 Extra Features $0 Physical Address � 36060 STABLE WILK AVE ZEPHYRHILLS, FL 33541 7ust Value $25,716 Assessed (Non-School Amendment 1) $25,716 Le�al Description (First 4�ines) � SILVERADO RANCH SUBDIVISION Taxable Value $25,716 PHASES 2, 3 &4 PB 73 PG 059 BLOCK 2 LOT l i Jurisdiction City of Zeehyrhills Land Detail (Card: 001 of 001) , --�-- — --r---------r- ----i-- –7---- Line � Use DescriptionZoning_ Units Type IPrice Condition Ualue e i__.__}-=0100 _� SFR ____ MPUD 6,000.00 SF � $4.25 �1.00__ � $25,500 , � 2 `I 0100 � SFR� MPUD � 655.00 � SF��$0.33 v� 1.00 $216 � Additional Land Information I FEMA ` �- � Acres 0.15 Tax Area 30SI 1 Code -- � Res�dential Code ' SLVRLPI j —� �'��-----; ( Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Fe___r atures (Card: 001 of 001) __ _ LineA`T_ `_�Description � lYear -�Y_-_-�Units ;Value �_^ No Extra Features � Sales History- See All 5 sales � Previous Owner: �, Month/Year �Book/Page __�Type rDOR Code�ondition �Amount � ; ---�------ i � 09/2011 8606 / 3376 _ j__ Warranty Deed 05 � Vacant I Multi�Parcel Sale �' ' , ` 05/2010' 8373 / 1912 � Certificate of Title 12 _____ _� V—acant - $0 ; 07/2005 �6725 / 1059 € Q tiu C ial m Deed j j-Vacant � $0 j � � � I http://search.pascopa.com/parcel.aspx?parce1=2126040070002000110 6/28/2017 � pG��. r���o������,a;� �a,.-. ' fi13-780-0020 � City of Zephyrhills Permit Application Fax-813-780-0021 ' ' � Building Department Date Received �� 813 363 __ 2891 Phone Contact for Permittin Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700 Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Naine N�A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 36060 Stable Wilk Avenue LOT# 0110 SUBDIVISION Silverado Ranch Subdivision Ph 2,3,&4 pARCEL ID# 04-26-21-0070-00200-0110 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED II./ II NEW CONSTR e ADD/ALT � SIGN 0 � DEMOLISH � INSTALL REPAIR PROPOSED USE � SFR Q COMM � OTHER TYPE OF CONSTRUCTION � BLOCK Q FRAME � STEEL � DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF 2357 SQ FOOTAGE �870 HEIGHT 2 StOfy ��TTITr rT'T�r1'��TTr 1"ITI"1'T�TP7TrTTTI�r BUILDING $ / VALUATION OF TOTAL CONSTRUCTION 11.�000 '�/ 'ELECTRICAL $ � PROGRESS ENERGY 0 W.R.E.C. ' � ` AMP SERVICE �PLUMBING $ ��/ �MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION � � �`i ��i , . � OGAS � ROOFING Q SPECIALTY 0 OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA �YES �O u -:-F:-FF-:-r:-F�I--4-4-��4-�--�-�-�-�--��4-E-�4-�4-�--F-E-�-F�-•�Fa--E-�-�--�•-�--�F-E-�-�-}-�-'-:--:-:-^4-�--4-F-+--�-:-r'-o--;-� BUILDER COMPANY Lennar Homes,LLC SIGNATURE i---- REGISTERED Y/ N FEE CURREN Y/N Address 4600 W.Cypr ss St.Ste.200,Tampa,FL 33607 License# CGC1518166 ELECTRICIAN COMPANY Edmonson Electric, �f1C. SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address , 1034 Skipp r Road, Tampa, FL 33613 License# EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE �� REGISTERED Y/ N FEE CURREN Y/N Address P:O. Box 530 , Bayonet, FL 34674-5308 License# CFC042998 MECHANICAL COMPANY Baydnet Plumbing, Heating &AC, Inc SIGNATURE � REGISTERED Y/ N FEE CURREN Y/N Address P.O Box 5308 Bayonet, FL 34674-5308 �icense# CAC058062 OTHER COMPANY �_ SIGNATURE REGISTERED Y/ N FEE CURREN Y/N ,address 4211 Shoal Lin Blvd, Spring Hill, FL 34607 �icense# CCC057991 � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, / Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. � Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Siit Fence installed, Sanitary Facilities&1 dumpster Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. *"`PROPERTY SURVEY required for all NEW construction. �1..4.:.�C..:..:�f..��L�l..��f.a..1���4��1..1��f��1--1�1..��1.�1..��4a..1���4.1..L�1..1..4�1..1��1..4.L..1..�1..1..L���1..1..��{� Directions: Fill out application completely Owner&Contractor sign back of application,notarized - If over$2500,a Notice of Commencement is required.. (A/C upgrades over$7500) " `* Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(PIoUSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTIC�OF DEED RESTRICTIONS The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES. The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release If the project does�not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended)� If valuation of work is$2,500.00 or more, I , certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT. I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. , - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill. - Use of fill is not allowed in Flood Zone"V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes Every permit issued shall become invalid unless the work authorized by such permit is commenced within six�months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTIC F COMMENCEMENT. I FLORIDA JURAT(F.S.117.03) � OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirm )before me this Subscribed and sworn to(or ffirmed)before me this i a-iviay-i i by paul Sweene 15-May-17 by Paul Sw ene - Who is/are personally known to me or Who is/are personally known to me or as identification. as identification. � Notar Public ' Nota Public I� Y �Y Commis n No. FF98537 Commis o FF98537 Elissa M.Holleran � Elissa M.Holleran Name of Notarv tvqed,printed or stamped Name of Notary typed,printed or stamped _ .�....�.� ,,.� ; __ ,,�� ��I�kN���OI�,�F#' _. . .. - ��I��hh�fi.�l�9�,�+tl �, � �etr.m�a'anit�,Ppa�e�� , a G�rr�n'�i'�t��PF�E�4�7 � �&��&►��i���d,�G��� �k�S4��,Futa����6�A ' r�k'�� � �,�+1nr,rr�Ks�tu9�t�t�ta�l1 �,�.. I��`41r�T�ay�+0�t+�etr���t�!l�TkN Lennar Fiomes-36060 Stable Wilk Ave-2351 sq ft-single family o umn � SQ. FEET PRICE � MAIN OR LIVING: 2,351 $ 106.36 ' OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ _ � �I VALUATION $ 250,052.36 � FEE SHEET $ 941.00 � i ADDRESS $ 40.00 I DRIVEWAY $ 40.00 i BUILDING: $ 1,039.82 I ELECTRICAL: $ 211.73 PLUMBING: $ 141.15 � MECHANICAL: $ 98.81 SUB-TOTAL $ 1,491.50 TOTAL $ 1,491.50 �i SEW ER: na � WATER: na � IRRIGATION: $ - TOTAL: $ - i WATER METER: na � IRRIGATION METER $ - � FIRE DEPARTMENT FEES PLANS TOTAL: na ; INSPECTION TOTAL: , PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES I� POLICE $ 254.00 FIRE $ 273.00 ' 5% $ 26.35 i TOTAL: $ 553.35 i I SUB-TOTAL $ 2,044.85 I PARK IMPACT FEES $ 769.56 I � SIF'S: $ 4,828.00 � 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,322.69 ' 36060 Stable Wilks Ave o umn SQ. FEET PRICE � UNDER ROOF: 2,351 $ 106.36 ' OTHER: - $ - VALUATION $ 250,052.36 FEE SHEET $ 941.00 ADDRESS $ 40.00 I � i DRIVEWAY $ 40.00 �' BUILDING: $ 1,039.82 ' i ELECTRICAL: $ 211.73 , PLUMBING: $ 141.15 MECHANICAL: $ 98.81 , SUB-TOTAL $ 1,491.50 � I TOTAL $ 1,497.50 , i SEWER: , WATER: IRRIGATION: $ - ' TOTAL: $ - ' WATER METER: ' IRRIGATION METER ' i FIRE DEPARTMENT FEES � PLANS TOTAL: I i INSPECTION TOTAL: PERMIT TOTAL � TOTAL: $ - �� PUBLIC SAFETY IMPACT FEES , POLICE $ 254.00 , FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 , i SUB-TOTAL $ 2,044.85 I i PARK IMPACT FEES $ 769.56 I SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 I T I F'S: $ 3,632.00 �I 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,322.69 �� � i IIIIIIII�IIIIIIIIII�IIIIIIIIIIIIIIIIIIIIIIIII � ' . . , IIIIIIIIIIIIIII188 — — • . _---- � i Rcpt:1874825 Ree: 10.00 ; DS: 0.00 IT: 0.00 � 06/27/2017 K. K. , Dpty Clerk _ � PRl1LR S 0'NEIL,Ph D PRSCO CLERK & COMPTROLLER 060R BK 1�5�`�m PG 3��� Permit No. Parcel ID No 04-26-21-0070-00200-0110 NOTICE OF COMMENCEMENT i State of Florida County of Pasco ; THE UNDERSIGNED hereby gives notice lhat improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, � the following information is provided in this Notice of Commencement: 1 Description of Property� Legal SILVERADO RANCH SUBDIVISION PHASES 2 3 &4 PB 73 PG 59 BLOCK 02 LOT 11_ � st�eetAaa�e55: 36060 Stable Wilk Avenue Zephryhills _ FL 33541 ! i ' 2. General Description of Improvement Single•Family Residence/Pool/Screen Enclosure/Fence � , 3 Owner Information: Lennar Homes, LLC_ � - Name 4600 W Cypress St Ste 200 Tampa FL. 33607 Address City State , Interest in Property� Name of Fee Simple Titleholder N�A � (If other than owner) Address City State a contractor• Lennar Homes, LLC Name 4600 W Cvpress St Ste 200 Tampa FL, 33607 Address City State j Contractor's Telephone No. 813 574 5700 , 5. Surety N/A Name i - Address City State " � Amount of Bond: $ Telephone No• s. �ender N/A ' Name Address City State , Lender's Tel"ephone No• � 7 Persons within the State of Florida designated by lhe owner upon whom notices or other documents may be served as provided by � Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes LL � Name � 4600 W Cvpress St Ste 200 ' Tampa FL, 33607 �, Address City State Telephone Nurpber of Designated Person: $13 574 5700 ; B. In addition to himself,the owner designates N/A of � to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATfORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA �� COUNTY OF PINELLAS � 5ignature of Owner or Owner's Authorized Officer/Director/Partner/Manager - Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this.�5 day of March o?�i�by Steve Robeft SYl'lith as ViCe President (type of authori .,officer,trustee,attorney in fact)for Lennar Homes LLC me of p on of whom instrument was executed). Personally Known�OR Produced Identification❑ Notary Si ature - Type of,ldentification Produced Name(Print) E�ISS olleran • Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. �� _ ' :�� �� ELISSAM.NOLLERAN 5ignature of Natural Person Signing Above � ';,�Gmmisefon�FF 885837 - � _' o"Ex�lree June 6,2010 - - � I wpdata/bcs/bcs form; �P����''��,9end�IThm7royFalnlMunnoel00�i5-7010 ' ' �����Grs���D a� .� �l � o ' � � �� � � `V9 '4•'.r•f �e?'�t � � S�A��OF�LO�IDA COUtJTY OF PA�GO �Q �„���� � ••� , � r; y ����. �-. � THIS IS TO CERTIFY 1'HAT THE FOREGOING IS A �T;A -� TRUE AND CORRECT COPY OH�THE DOCUMENT , �� �� -n��� ��' ON FILE OR OF PU�LIC RECORQ IN THIS OFFICE ,rr�'�`�`� - a ° �� WJ,T(�$�MY HAND ANU OFFICtA4.SE�4L THIS ��'W���� ���� DAY , 2 O / PA O'NEI LERK�COMPTROLLER BY �`—�`�" DEPU7Y CLERK /��O� /��y��'7J" I�CONII)q "�% "`a��-".�i�""`--r;� , •1/,�.1.; - �•i Cify of Zephyrhills � BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: 1�-1��-�G�--�' G�`��� � Date Received: �' 2 a"'�� Site: `?� � d�b u�'F�.bl(, J��� ��� � Permit Type: 2 �5 �� �j (J Approved w/no comments:❑ Approved w/the below comments� Denied w/the below comments: ❑ �� ��� ! � � ; _ � This comment sheet shall be kept with the pernut and/or plans. � " � � �a�� Ka vi � ' zer—Plans Examiner Date Contractor an or Homeowner (Required when comments are present) ^y n � �n.R � r � _ -r- �lr c' ,r �- _- � .� u� I �'�`1C.�'., , ^�� � '- �� �� 1�, �0 �• ��� , � i�1 M .D �jj�C • " �ie -. G, �a � s- s � �-` \NP= ; �� t ��,� , ,�p� ��y- �'� .,,�0 T� .�O 'S p'S a :, �O rt�-`•l"` 1,10 � � - � �f, s�� �_ - G,��'S ' � _� .�� ' Tg9- _ •a`b- ��,' f �'1 ��' TJ `T����-_ .�'� � -_ ' �- � :�>` ; ��'� -5�' y'1 z> �� � - T ;°��'-- _ �� � �•� o,,,�,�5 �€ . ix- OQ, _f�� • • �- O .G� • _ --- ----- -����' :� �' -�_ rr ,���j��•, 't�.�5.. *--- • C�• � � � ' n ,i. 0 ��i 1\ .� � e1z.• �;` �(� \ Q�� i ' v �0.J-. ��-y� / , 0. ♦ 7 .��. ,��5 p l �5 ,�b- r,�l' ,�O�' (� �� . p°�'1 0��$7; , _- +�• , \ s . ,<�p ��g;� �J 6� ��V ^O� -y��� _L�v =1v 1��: f1 J 1(7U A�. �� �` _'�C��.. . ' ' ' ' _ _ '�' G ipc�14.' �� �y`ti k �t ' . ` � � Obs ���� �. . Z ' ._'_ . . - . !1 �J` �= �` • v�9�- �,a --�O � -o,� d•,� � ----•-- `�------ 1� �1 � � - - - __ _ �p�l . Ct. __ � `r ,5� �. -�_ ��-Z-- ,'SG �� _ _ .o.o•o•D�°-O �-❑-a•o-o- � zG} ;�,�"- � � �a , � . �� -1- Q� g °� �� c�o . ;°��•� ' _-. �- Q ; ^ 1 1 � J ��'� ' ' ,�O� zo, a-o'O ,c "' .. � � _ - 5• - �'Q�sz-3-y � -� � 1 �� n`L �o-o.°- ,�.� ' ,�, N;� - c� Q � ,� � `L �p� E-.� �'l y�p"J �O�`,� __;_��'� �a o-o-D.O;�� ''C, -� ;�'` C ��pO �, , p'� -- �_�__ _ _ g _ 9 37 ' �� T c�. '- , ��C� e\ - '�,. � � T �, .o-a���j�a-o �-, - 1 ,� °, - _'�� n �,5 ,�°J . � _.a1 O ( •��`~ -� \`��1-��, � .�O � v y,� b _ C _ __ � �C.J\"� ��� ,�.p ��:'` l� ` c�.� _ 1' 1 O� O� -1��?'�L , �1�D�b0 ` 5'' X �1 ,,O � Q .f�9.90 1(�O'°'r''�l) � f- ;� � ''� ` �1 -.� FF=1Yj2.1 `i �� , � � � oU' -�- , • T LOT' 31 LO �0 � QT 29 FF=99.70 � 0 � LOT 32 PAD=1fl0.4 `' P�=gg•s ' 6 ���o:a _ a ' , FF=10�8 PAD=101.4 npE B '7��E g PAD=99.2 LOT.� ' � 30A 1_ %°J��\�� ' ` LOT � TYPE��B. P�49.0 FF=99.70, � 'G , � . T.YPE A/B � _ -- C�• , . _ � FF=104_fl P,l(9-1021 :�- E B LOT 27 , ��Jc � 4 LOT 34 ' �PE A g-' � PAD=99.0 '•g �16'• .� , � ��;�a � �� FF=]Q5_ AD=103�,3 . � cJ� 1YPE B =g9_�,tl, . � � ��. ? �� ` � LOT 35 TYPE A 6� •--- °c _ - � ---- - -___ - ra LQ �2.'S' -� w' �- ��';`� \� � FF=1�6.b AD=504.8 . 1- _�- -- �5�t� - --___ ' � PAB�8.9 ��'� ;g - a ,�1 � ` �� � LOT `36 �'� IYP�F A � 1 __-�, .o' �U - � 98.54 -- °�" • 7'(FE B� •5�`t' • -__ `� O ��%� p lqp'fP��_ �QJ C,�j r,�1 'l-- ;� r�v� G.� � -C�^� 1 �` �, 98.1 B�-„� ` f�P�E c�6.7 � �� , ' ��. � � 1 L ^�� , , , i�v e ' , ,�, � � �� \�� �� ,' � :�� � ' �i��1 � - rs D�1�. , ��\�. :�p �, •' 6�`� `G _ � - � \ ,:�, `� h �` `��0� , � � *.� :� .�y - , zz � �\ �` , _,_� . o� o�� . y� � � � ` � FF=99. �,5 �' ��t. �,�. ' ' .,5 g �; � ,o^. ,,J ,� r _ � _ LaT � -� 6'� � �k- J^O • � ' � _-�-_ r"---� =---- - +�__ _ ,� D ��`` PAD�8.9 1�� - " M1\ , J� •^ ` .- � � ` TYPE B ,U' . � � 'J '� '�� �S�' _--'-- .� � ''' °� ,� '''-_ o \ '1 ', ' •�o�'� ;jg B���'°�� - . � �v ,�c,- �• > �'h -� . 1 ,� �` . '�j-� p ;�D,.,� �, �D� - , � 4 ..,.�' � J , �` 1� u`6" oJ �. � �F=I 01_70 �FF=100_90 100_20 � sg• Q� ' 7�� � � * , . � � '�O� • p`L' FF=10 ; LOT 1 7 ' LOT 10 LOT 9 '� � 5� � � _ = i o - -'- �� L��. 12 AD=101.0 PAD=100_ PAD=99_5 � . "' � .n� r0 r r�� - � ,-� � '� ' •, FF=1a3.6 PA0=T0.1_9 , TYPE A�S � TYPE A �E A F=i00�0 91i-7 +b�1 • , p,�. _ _- `�- `J�: '° , L0� 13 1YPE 6. � � v� PAD�99_5 � FF=105.0 AQ�•�2-9 _^��� 1 '' 0 � � '� I �`99.70 _ ��- a. �� _ J L , ��, LOT 14 � �E A c ,o ;_ � p.�p. A � 1(I 1? -i�'I LOT 25 � f d � FF=106.4 AD=104.3 - �,^� ' _'I�� 0� �� - � � � 8_2 - PAD=99_0 - - � ��r:� � L� 15 TYPE A �' __��' •, !c Y c�F B . C t.� ���ir � h AD=1 D�_7 . � � ,1 8 - r � ^i ��'. �b �� �`� ` 7YPE d � �� _ ; � 1 �. '�4? � � �j- )�' ' � b� ��� �'� i t�Q3_5 � �'_ ' ,- r�4..•. 2� '� _ / ,y.� ��'`l�� C'� - ��' ,�U�' ,� � Dc � • .s , r• �y 9' �'T _ - - Dc1 �'� � o - - ' 7 � p� p� 4� �4 �, FF-100_30� . g. , /ti ` `1 � ', � r' 10 g_ �`�• LOT 24��, ���,o- -� � '�ry 4�i og , •� L• �\ � ``i� �� � C� PAD=99_6 , r ro ' p.q _ ` ro � �5 ,r I: � ^� ' $ ' , J � TYPE B 1�� c... 5: '�i � a ' ` •a� =�� g1,� � 1" o FF=1D6.2 � LOT55 � FF=105.00 �'. /!J`� -�- �� •'L - ._ • te-ce r={`d , , 1, �i °� �, - LOT 4 ,, PaD=t o5.o LOT 6 =�04:�0 ,o � a�a , , - '- �i � _ � PAD=104-3 LOT 7`, i 1 / � ��� ' � 'l- ', , ; FF=107_ . PAD=1 Q5.5 ,Q,('PE B i �'� m _ � � �i , LOT .3 TYPE B - ��B PAD=1p3�fi o � �� o ' 1 lA _ t•_ � � rN*� \ �� 0. FF=107_7 AD=106 � ,, ''+ " c�L o c� �r� FF=1�2.4D g. - ����5' I 'O� ^�,� �.� o, _ r,-P� ' °' _ tU• LOT 23 -- � � p � , • �'� ��`' � � � �� LOT� 2 TYPE B`� .�a i� _ �O ��� � o - _g P 10�.7 '��°J `���. _�\ `�O �� � ^ FF='t#7'8.0 AD=107i� " - . -`' B. , _ �� . � ,�o �T ^� �.OT 1 TYPE H. ,. � ---- ;O�rQ•_ ` l ;�� � � .0 ,. ���� f ` � " � � � 1��^ �G � � � � Pkb=107.3 ' � � _'� -- , - � --- �- -- -- � 1 1 �� �T 1. � � 77PE B - -- --- --- � G ^� `� ' �oSE`�ENS '_ _ �1 - Dc � I �� r� 1.�2.30 ' �' b� � e \ � � -- a � � � . ��T �� �� as. , _._ :°� �,�� PLCITPLAN � SKETCH ONLY SEC. �4 , TWP. 26 S, RNG. 21 E. LOT 1'I, BLOCK 2 NOT A BOUNDARY SURVEY g�RaN� eAsts: SILVERAD� RANCH SUBDIVISION NpRTH BOUNDARY OF SE� OF 04-26-27 BEING N 89'S6'26" E PHASES Z, � t4C �- TNIS SURVEY IS SUBJECT TO ANY FACTS THAT PASCO GOUNTY, FL.ORIDA. � MAY BE DISCLOSED BY A FULL AND ACCURATE i1TLE SEARCH. ALSO SUBJECT TO SETBACKS, PREL.IMINARY DRAWiN6: EASEM,ENTS ANQ RESTRtGTtONS OF RECORD. TiitS P�AN tS FOR PERMITitNG PUftPOSES ONLY, NOT FOR CONSTRUCl10N. VERIFY M UNDERGROUND FOOTER, STEM WALL, AND ALL DIMENSIONS BEFClRE ANY C�NSTRUCTION. �! UNDERGROUND UTILI7lES ARE NOT LOCATED qR ( SNOW�it_ LEGEfVD: ��.-= PftOPOSEO DRAINAGE FLOW 'w�� DO NOT SCAI.E THIS PRINT. DIMENSIONS AND NOTES TAKE PREFERENCE. {Ofl.00} = PROP4SED GRADE � £-00.00 = EXISTiIVG GRADE � DESCRIP710N NOT CONTAINING PLAT BOOK AND PAGE INQICATES THAT PLAT IS IN i NOTES' PRELIMlNAftY STAGE AND IS SUBJECT TO LOT GRADiNG TYPE = A GHANGE AND/OR REVISI�N. PROPQSED PAO ELEVATION = 1Q1.00' � CERTAIN DATA SHOWN HEREON BASEp ON fRONT SETBACK = 20' or 22' ENGlN�ERING PLANS PROVlDED BY CLIEN7. StdE SETBACK = 7.5' ' REAR SETBACK = 15� A��N�� MEASU EMENT FROM ORM�BOARDS/FO NDA710N S�ABL� �I�K�� L} T4 PRQPERTY L1NE. �W) t �.--- -^- i * = 10' UTILITY EASEMENT � � �- • .0•'� sr�.i:-^^- M• i G? • � . . �.. _..j... .. ..A. �:,V,�7.1 � ,:. _ . _ � A y .- � 'O;-- . * • .N t9929J • G4. �^.� ..."Q. m` ' ��, 'o-^ tl , :.16.00�^'� \ � . 7 �CtP} ' ..l6.tt:- .��6.11' I � pROFOSEO � � PIAN T N 1871 � , EIEV "g�� �' � GARAGE a � ' tEFT � � �OT 11 , ^ gLOCK 2 p LOT 10 � � BLQCK 2 ; LOT 12 N 30'Jp„ t3.e6'. � BLOCK 2 � 53.86' A��Q: o � . : � i ON LOT AREA CAL.GUL,ATIONS I ( Z . � L.OT = 6655.60 SQ. FT. t.EVING AREA = ?$� SQ. F?. � . ENTRY = 3S S�. FT. ,'�� GARAGE 443 S�. FT. '`��° �� `r� GOVEftED LANAt �1.JA SQ. F'T. I -N °a PAltO =�A S4. FF. o�� 2�.% CONC. DftIVE = 363 SQ. F7. � ho� • A/C & GONC PAD =9 SQ. FT. �- � . PRNA'(E SIdEWAE�K = 33 __SQ. FT. � Qq1 IMPERVIOUS 25 % � og� 1666 SQ. FT. � Q ,� rT SQD = 4s90 SQ. f7. (' `° ---- ' �o� S 85"50 41" W 52.51' °�pa ( �I �r OFF L.OT AREA GALCULATIONS j � `ti �oT � RIGHT OF WAY = t180.51_SQ. FT. r ' BLOCK 2 DfttVE AFRON = �33 S4. F'1: ° � ��� 4 I PUBLIC SIDEWALK - 325 SQ. FT. � a BLOCK 2 ` SOD = �23 SQ. FT. N 4 TOTALS `� AREA =�836.11 SQ. FT. � DRIVEWAY = 59fi SQ. FT, � SIDEWAC.K = 358 SQ. F7. �O SOD = 5613 _SQ. FT. J D�SGRIPTIOIN: PRQPt�SEE}: � LOT 11, BLOCK 2, MAP OR PtAT ENTiTLED "S11�VERAdO t LOWEST FLOOR ELEVATIONS: m RANCH SUBDIVISIQN PHASES 2, 3 & 4", AS RECORDED IN LIVING AREA: 101.70' M PEAT BOOK 73, PAGES 59 TFEROUGN 65, OF THE PUB�[C GARAGE AftEA: r!, RECORDS OF PASCO COUNTY, FLORIDA. , ELEVATIONS REFERENCED TQ , a' CURVE RADlUS ARC CHOftQ BEARiNG DELTA NORTH AMERICAN VERTICAL ', z CD 665A0' 81.86' Si.80' N 78'i2b4" E 07'45'09" dA�� {�F Tg��• ��A� SE�1 v C97 605.p0' 64.62' 64.59' N 65'OB'15" E 06'07'12�• LEVEL= 00.00 FT. ti a 1 o APPARENT FLOOD HAZARD ZONE: ,�X" COtv1MUNITY PANEL N�. 120230 0455 D EFFECT]VE DATE: 09/30f9992 � LEGEND: ,-,,"�. (C)= CALCULA7ED DA7A, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, �= CENTERIINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/5= � CONCftETE SlAB, Cli= CHORD, CH6= CHQRD BEARtNG, CLF= GHAIN LINK FENGE, CQNG- CONCRETE, COV.= COVERED, £jP= EDGE dF PAVEMENT, ESM'T= EASEMENT, �^'F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= �'OUND IRON PIPE, FIR= FOUND IRON ROD, FN&D- FOUND NAIL & DISK, FT�P= FQUND PINCHED � PIPE, LFE= LOWEST FLOOR ELEVAiION, MAS.= MASONRY, OR= OFFlCIAL RECORD BOOK,. PB= PLAT BOOK, pCP= PERMANENT CONIROL POINT, PRM� PERMANENT Q REFERENCE MONUMENT, RfW= RIGHT OF WAY, R= RAO(US, SIR=5EF i/2"' IRON ROD & CAP No: 4493, SN&Q= SET NAl� & DiSK, TSM= TEMP4RARY BENCHMARK, � U P= UTILtTY POLE, W F= WOdD FENCE, R = RADIAE. � Q Drawn By. Square.�Feet: 6655.60 t LENNAR HOMES Q JOHN R.BEp,CH&ASSOCIAT�S,ING. gMs � `�' SURVEYORS AND MAPPERS � l 91t WEST ST. PETERSBURG DRNE Checked By. - v� ONE OLDSMAR, FLORIDA 34677 JRB N WAY (813) 854--1276 FAX (873) 855-8370 Scale: i"=3Q' c 0 �} NOT VALID WITHOUT ThIE SiGNANRE AND Dote: PLOT PLAM 5 23 17 ACS - �S �� � �o THE ORIGINAL RAISED SEAL OF A FLORIDA JOH . BEACH dATE � UCENSED SURVEYQR AND MAPPER FL�RID G. t_AND SURVEYOR No. 29$4 LS 493 n i Revisions: � PLOTPL,AN SKETCH ONI.Y SEC. d4 , TWP. 26 S, RNG. 2� E. ; LOT 11, BLOCK 2 NOT A BOUNQARY SURVEY gEARtNG BASIS: � SILVERAI�O RANCH SUBDIVISION NORTH BOUNDARY OF SE� OF 04�26-21 BEING N 89'S6'26" E PHASES 2> 3 & 4 PASCO COUNTY, FLOR(DA. � TH1S SISRVEY tS SUBJECT TO AhlY FACTS THAT MAY BE DISCLOSED BY A FULL AND ACCURATE TITLE SEARCH. AL50 SUBJECT TO SETBACKS, PR�LiMiNARY DRAWITi�: EasEM��3s a�o R�s�nz�cnoNs oF �Eco�D. 'IHtS PIAN (S FOR PEfttJ1TT1NG PURPOSES - M UNDERGROUND FOOTER, STEM WALL, AND ONLY, NOT FOR CONSIRUCTION. VERIFY ALL pIMENSIQNS BEFORE ANY CONSTRUCTION. �� UNDERGROUND UTILITIES ARE NOT LOCATED OR SNOWN. LEGEND: ✓--�= PftOPOSED DRAINAGE FLOW 'wJ DO NOT SCALE THIS PRINT. DIMENSIQNS AND NO7ES TAKE PREFERENCE. {00.00) = PROPflSED GRADE � E-00.00 = EXtSTiNG GRADE � DESCRiPTION NOT CONTAINtNG PLA7 BOOK AND, PAGE INDICATES THAT PLA7 IS IN � NO'TES; PRELIMINARY STAGE AND IS SUBJECT TO LOT GRADlNG 'fYPE = A CNANGE ANQjOR REViSSON. PROPOSED PAD ELEVATION � 101.00' CERTAIN DATA SHOWN HEREON BASED ON PRONT SE7BACK = 20' or 22' ENGlNEERlNG PLANS PRQVlDEQ BY CLIENT. � SldE SETBACK = 7.5" REAR SETBACK = 15' STRUCTURE i1ES SHOWN HEREON pENOTES 5�.�8�� ���K AVENUE MEASUREMENT FROM FORM BOARDS/FOUNDATION 1RACT L) TO PRQPER1Y LlNE. �so'�zlw) ( �.-- — � �„�.---� * = 10' UTILITY EASEMENT � �i „� I i ��,,�-� :-�''+,�'• •o .�;,•� :+`� M . � + ^ ...�,:,' ' . �a.. G97 s '` , . .. — , _ . . . � ., f......� ':.s^s �^O1� •dF � fN _ f99�9J � •.�...�^'�L�+ �O �..��,N..�—NN. `.�.�i:.:... .�" ��. � M�6.00�`• � ��p7 � 'ts.i7' �� j ..•�s.ii' i� pftOPOSER � � PLAN T � 1871 � N ELEV "g�� ^' � GARA�E p �.EFt � � �OT 11 - BLOCK 2 o LOT 10 B�OGK 2 LOT 12 � 30''p� t3.s6' d�- � BLOCK 2 � t3.e5'. A��(�' p ; O � . ON LOT AREA�AL.GUL,ATIONS 'Z ' LOT = 6655.60 gq. F'(', CIVING AREA = 78� SQ. FT. � � ENTRY = 38 S0. FT. :p !�'o' GARAGE 443 „�,S�. FT. :Q a� `r� COVERED LANAt NlA S4. �1'. � =� °Q? PA110 =�A SQ. FT. o� . °J CONC. DRIVE = 363 SQ. FT. Q° ' • AfC & CONC PAD = 9 SQ. FT. L - � PR(VATE S@EWAIX = 33 gp. FT. � o� . } IMPERVIOUS =25 % o�yQ = 1666 SQ. Ft. ' 4 : .� * r� SOD = 4990 SQ. FT. � `° --�— � �o S 85°50 41" W 52.51 �"ao � OFF'LOT AREA GAL�UL,ATIONS j M `o� ���, � RIGHT OF WAY — 1180.51 gQ, F'(', � QR(VE APRflN = 233 S�. F"�; � BLOCK 2 PUBLIC SIDEWALK = 325 SQ. F"I`. r. LOT 4 SOD 623 SQ. F1'. � BLOCK 2 — � � TOTALS ,� � AREA = 7836�.1_SQ. fT. DRIVEWAY = 596 SQ. FT. � StDEWAUC = 35$ SQ. Fl: �° SOD = 5613 SQ. F1'. � D�5CRlPTiCJN: PROPQSED: � LOT 11, BLOCK 2, MAP OR PLAT ENTiTLED "SILVERADO LQWEST FLOOR ELEVATIONS: m RANCH SUBDIVI510N PHASES 2, 3 & 4", AS RECORDED IN LIVING AREA: 101.7Q' � PLAT SOOK 73, PAGES 59 THROUGN 65, OF THE !'UBL(C GARAGE ARER: ry REGORDS OF PASCO COUN7Y, FLORIDA. ELEVATIONS REFERENCED TO ' n' CURVE RApkUS ARC CHORD BEARiNG DEl7A NORTH AMERICAN VERTICAL z ca 605.00` 81.8fi' 81.80• w �a72•oa^ e o��as'as� DAT11M OF 1988. MEAN SEA ti C97 605.00' 64,62' 64.59' N 85'OB'15" E 06'07'12" LEVEL= 00.00 FT. � 1 g APPARENT FLOOD HAZARD ZQNE: "7C" COMMUNITY PANEL Nt7_ 120230 0455 D EFFEC7IVE DATE: 09j30j9992 � LEGENU: � (C)= CALCULATED DATA, (D)- DEED DATA, (M)= MEASURED pATA, (P)= P�AT DATA, @= CENTERLINE, A/C= AIR CONDI770NER, 8/C= BACK OF CURB, C/S= � G4NCRETE S�AB, GH= CHORD, CHB= CHOftD BEftRING, CLF= CNAtN LtNK FENCE, GONC- CONCRETE, GOV.= GflVERED, EJF= EDGE OF PAVEMEN7, ESM'T- EASEMENT, /FJC= FENCE CORNER, FCM= FQUND CONCRETE MONUMENT, FiP= FQUND IRON P1PE, FlR= FOUND IRON ROD, FN&p= FOUND NA1L & DISK, FPP= FQUND P�NCHED � PIPE, LFE= LOWEST FLOOR ELEVAiION, MAS.= MASONRY, OR= OFFlCIAL RECORD BOOK. PB= PLAT BOOK, PCP= PERMANENT CONTRaL POINT. PRM— PERMANENT d REFERENCE MONUMENT, R/W= fttGHT QF WAY, R= ftADlUS, SlR=SET 1/2"' lRON ROD & CAP No. 4493, SN&D= SET NAi� & D15K, TBM= TEMPORARY BENCHMARK, � U P= Ull�(TY AOLE, W F= W{70D FENCE, R = RADIA� � Drawn By. Square Feet: 6655.60 t LENNAR HOMES � JOHh1 R.BEACH&ASSOCIAT�S,INC. sMs � SURVEYORS AND MAPPERS Checked By: � 921 WEST ST. PETERSBURG DRtVE �RB � ONE OLDSMAR, FLORIDA 3h677 � WAY (g13) 854-1276 FAX (813) 555-8370 Scale: ���=30' ; NOT VALID WITHOUT THE SIGNANRE AND p4te: P�OT PLAN S 23 17 ACS �S I'���� o THE ORIGINAL RAISED SEAL OF A FLORIDA JOH . BEACM DATE � UCENSEO SURVEYOR ANp MAPPER FLORlD G. LAND SURVEYOR No. 2984 L,B 4493 n t' Revrsions. . . . �I Single Family Dwelling Plan Review Comments �, , 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete. � 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have � expansion materiaL 6. All setbacks shall be met. � 7. All property markers shall be uncovered and marked at time of first inspection. ' 8. All A.D.A. requirements shall be met. � 9. No electric,plumbing, mechanical, or framing shall be covered without an inspection and ' � approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 � 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. ' 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. ! 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all ! underground plumbing and electric. i 22. A112008 N.E.C. Codes will be enforced. � 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 �, 22. In accordance with the Land Development Code, lots shall be sodded before final at least 10 ; feet around the structure. ! F.F.E.-Finished Floor Elevation F.B.C-Florida Building Code 5�'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008) I � - - - - _ - - -- - - _- - - _ - - _ �QuI.tuncoct���ir«w;�CeM r/ • $��-78�a2Q , City of Zephyrhills Permit Application Faz-a�a�sa-oozT Buildfng Department Date Received �� pfione ConWct for Permittin 613 363 2891 Owners Name Lennar Homes,LLG Owner Phons Number 813.574.5700 Owner's Address 4600 W.Cypress SL Ste.200,Tampa,FL 33607 Owner Phone Number l 7 Fes S1mple'fltleholder Naina NIA -� Owner Phone Nnmber �•- � N/A � Pee Slmpie Titleho3der Address � JOBADDRESS 36060 Stable Wilk Avenue LOT# p110 � Sitverado Ranch Subdivisfon Ph 2,s.aa 04-26-21-0070-00200-4110 �' SUBDIVt510N PARCE�iD# (09TAINED FROM PROPERTY TAX NO710E) � WORKPROPQSED II�II NEWCONSTRB ADDlALT � SIGN Q Q DEMO�ISH � INSTAIL REPAlR I PROPOSED USE � SFR Q COMM � OTHER 'TYPE OF CONSTRUC7tON �f $LQCSC Q �RANSE � STEEL Q � , DESCRIPTION OF WORK Single FamIly Reszdence/Pool/Screen Endosure/Fence BUlIDING S1ZE UJR SF 2�rj7 � gQ FOOTAGE �$7� HEIGHT 2 Stfl�Y i f BUlIDlNG S 1 f��4 o VAIUAT(QN QF TOTA�CONSTRUCTION ' IL �ELECTRICAL $ � PRQGRESS ENERGY Q W.R.E.C. � AMP SERV{CE �PLUMBIM17G ($�� � �MECHANSGAt. �� VA�UATIOFI OF MECHAHICAL INSTAItATtON � � �GAS � ROOFING Q SPECIALTY � OTHER FIAlIStiED F400R EGEVATIONS � � FL66D ZONE AREA �YES �O LJ BUILDER � COMPANY Lennar Holnes,LLC � SIGNATURE r--�- REGISTERED Y/ N FEE CURREN Y/N ' 40 W.Cypr ss St.Ste.200,Tainga,FL 33b07� CGCiSt$266 � � Address 6 _� License# ......„. ... , ELECTRiC1Ak COMPANY Edmonson Electric,�f1C. � SIGNAIt7RE aEGiS�r�o Y 1 N FeE curtttEN Y/N Address 1034 Skipp r Road,Tampa,FL 33613 �icense# �C130054b8 � siaNnruR� r— RE��sTEREo Ba onet Plumbing, Heafing&AC, Inc � , PLUMBER � � COMPANY Y / N FEE CURftEN Y/N P:O.Box 530 ,Bay.- c�dress onet,F�34674-5308 ucense# �FC042998 � m�eHariicai coma;4r�v Bayo�net Plumbing, Heating&AG, Inc SIGNATURE I RE�aS�Reo Y 1 N �e cuRa�� Y t H � P.O.Box 5308 Ba onet,FL 94674-5308 CAC058062 � � Addresa Y License# � OTHER �_ COMPANY � ' SIGNATURE RE6ISTERED Y/ N FEE CURREN Y/N , Address 42 S 1 Shoal Lin Blvd,Spring HiII,F�.34647 ucense� ��C457991 � 11lIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIillltlltlllllllllltt � RESIDENI7AL Attach(2)Plot Plans;(2)sets of Bullding Plans;(1)set of Energy Farms;R-O-W Permit for new constructfon, Mfnimum ten(10}vrocking days after submittai data. Required onsite,Gonsiruction Plans,S#ormwater Ptans wt Siit Fence instaiied, , Sanitary Facilities&1 dumpster,Site Work Pertnit for subdivisions/large projects I CCIMMERCIAL Attach(2)complete sels o(Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-0-W Permit for new construction. M(nimum ten(10)working days afler submirial dafe. Required onsite,Construc2ion Plans,Stormwater Plans w!Silt Fence installed, � Santtary Facilities&7 dumpstec Site Work Aeanit for ali new projects.Ait commerciai reqairemeMs mnst meet compiia�ce SIGN PERMiT Aflacfi(2)sets of Engineered Plans. •""PROPERTY SURVEY required for all NEW constructfon. . . . . . ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , . . . Directlons: , Fi11 out application completely Owner 8 Contractor sign back of application,notarized If ovec$2500,a Notice ot Conimencement is roquired.. (AtG upgrades over$7500) � " Agent(for the contractor}or pawer of Attomey(for ihe awner)would 6e someone with notarized Ietter from owner authorizing same OVER THE COUN7ER PERMIITING (copy of contract required) Reroofsifshi�gtes Sewers Service Upgrades A!C Fences(PIoUSutveytFootage) Oriveways-Not over Counter if an public roadways..needs ROW F � , FORM R405-2014 FLORIDA ENERGY EFFfCIENCY CODE FOR BUILDIRlG CONSTRUCTION � Florida Department of Business and Professional Regulation - Residential Performance Method � Project Name: 1871 sf ADS elev B Builder Name: Lennar Homes � screet: 36060 Stable Wilk Avenue Permit Office: Cl-Ly���phyrhills � City,State,Zip: ,FL, Permit Number � I Owner• Lennar Homes Jurisdiction: 61160 � Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) I 1 New construction or existing New(From Plans) 9. Wall Types(2361.0 sqft.) Insulation Area I a.Frame-Wood, Exterior R=11.0 1152.00 ft2 � + 2. Single family or multiple family Single-family , b.Concrete Block-Int Insul,Exterior R=4 1 846.44 ft' 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 362.56 ft2 �• 4 Number of Bedrooms 4 d.N/A R= ftz 5. Is this a worst case? 10.Ceiling Types (1090.0 sqft.) Insulation Area I Yes a.Under Attic(Vented) R=30.0 1090.00 ftZ ' 6. Conditioned floor area above grade(ftZ) 1870 b.N/A R= ftZ � Conditioned floor area below grade(ft2) 0 c.N/A R= ftz i 11 Ducts R ft2 � 7 Windows(170.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 374 � a. U-Factor Dbl,U=0.54 87.00 ft' SHGC: SHGC=0.31 b. U-Factor Dbl,U=0.56 49.69 ftz 12.Cooling systems kBtu/hr E�ciency. SHGC: SHGC=0.28 a.Central Unit 34.2 SEER:15.00 ! c. U-Factor Dbl,U=0.56 33.33 ftZ ; SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency � d. U-Factor N/A ftz a.Electric Heat Pump 32.8 HSPF:8.50 i SHGC: ; Area Weighted Average Overhang Depth: 1.369 ft. � Area Weighted Average SHGC: ' 0.303 14 Hot water systems ; - 8. Floor Types (1870.0 sqft.) Insulation Area a.Electric Cap:40 gallons ' EF 0.950 a.Slab-On-Grade Edge Insulation R=0.0 780.00 ftz b. Conservation features b.Floor Over Other Space R=0.0 647.00 ft' None � c.other(see details) R= 443.00 ft2 15.Credits Pstat Glass/Floor Area: 0.091 Total Proposed Modified Loads: 61.79 pASS � Total Baseline Loads. 63.98 i I � I hereby certify that the plans and specifications covered by Review of the plans and �����"'.��.� . i this calculation are in compliance with the Florida Energy specifications covered by this ��, ,e"',�4:` +��,�,, I o- Code. calculation indicates compliance �'��i,��`�'�` `_`'"'�a�`. .�`. with the Florida Energy Code. # �rF;r�`.'�r�.===°��',��i`,;z�0. � PREPARED BY: �GII�e f�G�j'IGGI Before construction is completed w. � . �� � I ��^��� _f...,:. . .t� DATE: this building will be inspected for �,ry. ":��` . �,. � compliance with Section 553.908 $ �'� ,� ; Florida Statutes. t j I hereby certify that this building,as designed, is in compliance '+�+ �.;�� with the Florida Energy Code. �'�1?yy�,`� ; � OWNER/AGENT. BUILDING FF IAL. I DATE: DATE: '- � - Compliance requires certification by the air handler unit manufacturer that the air handler e c sure qualifies as ! certified factory-sealed in accordance with R403.2.2.1. i -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage ; test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. , 5/30/2017 1 44 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 I , i ._ � • " • . i FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method , Project Name: 1871 sf ADS elev B Builder Name: Lennar Homes ; street: 36060 Stable Wilk Avenue Permit ot�ice: City of Zephyrhills j City,State,Zip: ,FL, Permit Number Owner Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) I 1 New construction or existing New(From Plans) 9. Wall Types(2361.0 sqft.) Insulation Area , 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1152.00 ftZ , b.Concrete Block-Int Insul,Exterior R=4 1 846.44 ftz 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 362.56 ft2 4. Number of Bedrooms 4 d.N/A R= ft' 10.Ceiling Types (1090.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1090.00 ftz 6. Conditioned floor area above grade(ft2) 1870 , b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ ' 11 Ducts R ft� 7. Windows(170.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 374 a. U-Factor• Dbl,U=0.54 87.00 ftZ ' SHGC: SHGC=0.31 b. U-Factor Dbl,U=0.56 49.69 ftZ 12•Cooling systems , kBtu/hr E�ciency SHGC: SHGC=0.28 a.Central Unit 34.2 SEER:15.00 c. U-Factor Dbl,U=0.56 33.33 ft' SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency ' d. U-Factor• N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 SHGC: � Area Weighted Average Overhang Depth. 1.369 ft. , Area Weighted Average SHGC� 0.303 14 Hot water systems a.Electric Cap:40 gallons 8. Floor Types (1870.0 sqft.) Insulation Area EF 0.950 a.Slab-On-Grade Edge Insulation R=0.0 780.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 647.00 ftz None � c.other(see details) R= 443.00 ft2 15.Credits ' Pstat Glass/Floor Area: 0.091 Total Proposed Modified Loads. 61.79 pASS Total Baseline Loads: 63.98 I hereby certify that the plans and specifications covered by Review of the plans and �'�'C�'�rQ?.,�. � - this calculation are in compliance with the Florida Energy specifications covered by this ,� ,� _� �'7�,, . Code. calculation indicates compliance rr,`C'r,,,�, :_`-_,-'.,���.*�lt�. . /, with the Florida�Energy Code. ��rF�rr��.�.°:�:.�•;�,��,,'�,�„ti � ', PREPARED BY. �aVe �����'` Before construction is completed w�����r; .� d ; DATE. this building will be inspected for try. �;;:��:E� s} compliance with Section 553.908 •* �''� �- I hereby certify that this building, as designed, is in compliance Florida Statutes. �,� �,. . ���+ , with the Florida Energy Code. � ��a�S'E`� ; OWNER/AGENT: BUILDING O FICIAL. DATE: DATE: - - , - Compliance reguires certification by the air handler unit manufacturer that the air handler e closure qualifies as � certified factory-sealed in accordance with R403.2.2.1. , -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, ' tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. 5/30/2017 1 44 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 � I , ; ' � ' • I FORM R405-2014 I FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTlON � Florida Department of Business and Professional Regulation - Residential Performance Method - , , Froject Name: 1871 sf ADS elev B • Builder Name: Lennar Homes � �', street: 36060 Stable Wilk Avenue� Permi�off�e: City of Zephyrhills ! City,State,Zip: ,FL, Permit Number � Owner Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa ' County� Pasco(Florida Climate Zone 2) � 1. New construction or existing New(From Plans) 9. Wall Types(2361.0 sqft.) Insulation Area ' I 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1152.00 ft2 � b.Concrete Block-Int Insul,Exterior R=4.1 846.44 ft� , 3. Number of units,if multiple family 1_ c.Frame-Wood,Adjacent R=11.0 362.56 ftZ 4. Number of Bedroams 4 d.N/A R= ft� 5. Is this a worst case? Yes 10.Ceiling Types (1090.0 sqft.) Insulation Area � a.Under Attic(Vented) R=30.0 1090.00 ft 6. Conditioned floor area above grade(ft2) 1870 b.N/A R= ft� Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ 11 Ducts R ftZ � 7. Windows(170.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 374 a. U-Factor Dbl,U=0.54 87.00 ft' SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 49.69 ftZ 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 34.2 SEER:15.00 c. U-Factor: Dbl,U=0.56 33.33 ftZ i SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency � d. U-Factor� N/A ftz a.Electric Heat Pump 32.8 HSPF:8.50 � SHGC: � � Area Weighted Average Overhang Depth: 1.369 ft. � Area Weighted Average SHGC: 0.303 14 Hot water systems , 8. Floor Types (1870.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF 0.950 a.Slab-On-Grade Edge Insulation R=0.0 780.00 ftZ b. Conservation features I b.Floor Over Other Space R=0.0 647.00 ft' None c.other(see details) R= 443.00 ftZ _ 15.Credits - Pstat Total Proposed Modified Loads: 61.79 PASS Glass/Floor Area. 0.091 Total Baseline Loads: 63.98 I I hereby certify that the plans and specifications covered by Review of the plans and �'S�$T.q?':'�. . O � , � � this calculation are in compliance with the Flonda Energy specifications covered by this " ,=�;�, �'3r,�, Code. calculation indicates compliance r,J�.lf,;''l' '__;;;` "� � ,{/,� with the Florida Ener Code. h+ ,Ir;,rr�'"'�::�'�"�,�"��;��C9 � �aV� WL 9Y �, � '�,;;�, i PREPARED BY' r1 ��� Before construction is completed w , � � i DATE: this building will be inspected for �����'..:• � � i ��I: compliance with Section 553.908 ,�'�� � : � I hereby certify that this building,as designed, is in compliance Florida Statutes. ?",�, �� with the Florida Energy Code. � ��D W:E`�' OWNER/AGENT: BUILDING OF ICIAL. ' DATE: DATE: ' '' - Compliance requires certification by the�air handler unit manufacturer that the air handler e cl ure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. 5/30/2017 1�44 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 , , - , FC1RM R405-2014 � ' PROJEC`C i Title: 1871 sf AIIS elev B Bedrooms: 4 Address Type: S#reet Rddress � Building Type. User Conditioned Area: 1870 Lot# � Owner Lennar Homas 7otal Stories: 2 Block/SubDivision: #of Units: 1 Worst Gase: Yes PiatBook: Builder Name. Lennar Homes Rotate Angle: 45 Street: � Permit Office; Cross Ventilation: Caunty Pasco � Jurisdiction: Whole House Fan: Cify,State,Zip: , { Family Type: Single-family FL, ' NewlExisting: New{Fram Plans} � Comment: CLIMAT� � J IECC Design Temp !nt Design Temp Heating Design Baily Temp , V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range , FL,Tampa FL TAMPA_INTERNATI 2 39 91 74 75 845.5 54 Medium + g�ocKs ; Number Name Area Volume 1 83ack1 1874 15428 � SPACES _ � Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 1 st Floor 780 6708 Yes 0 1 Yas Yes Yes � 2 2nd Floor 1090 8720 No 5 4 1 Yes Yes Yes i � FLOORS i # Floar Type 8pace Perimeter Perimeter R-Value Area Joist E2-Value Tile Waod Garpet ' 1 Slab-On-Grade Edge Insulatio ist Floor 118 ft 0 780 ftZ M__ 0.3 0 0.7 2 Floor over Garage 2nd Floor � ._— 443 ftz 11 0 0 1 � 3 F3oot Over Other Space 2nd Floar .�� _� 647 ft2 0 0.3 Q 0.7 � I ROOF i / Roof Gable Raof Solar SA Emitt Emitt Deck Pitch � 1� # Type Materiats Araa Area Color Absor. Tested 7ested lnsul. (degj � 1 Hip Composition shingles 1368 ftZ 0 ftZ Medium 0.85 No 0.9 No 0 26.6 ATTIC i V # Type Ventilation Vent Ratio(1 in) Area RBS IRGC I 1 Full atfic Ventad 304 1223 ft2 N t3 � i � 5/30/2017 1�44 PM EnergyGauge�USA-FleRes2014 Section R405.4 1 Compliant Software Page 2 of 5 1 � �� � I, . . � FORM R405-2014 • CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type ' 1 Under Attic(Vented) 2nd Floor 30 Blown 1090 ft2 0.11 Wood � I WALLS - i Adjacent S a� Cavity Width Height Sheathing Framing Solar Below ; P o _ 1 N=>NE Exterior Concrete Block-Int Insul 1 st Floor 4.0999 9 8 8 78.0 ftZ 0 0.600000 0 , _2 E=>SE Exterior Concrete Block-Int Insul 1 st Floor 4.0999 37 8 8 8 326.4 ft2 0 0.600000 0 _3 S=>SW Exterior Concrete Block-Int Insul 1 st Floor 4.0999 24 8 8 208.0 ft' 0 0.600000 0 , _4 W=>NW Exterior Concrete Block-Int Insul 1 st Floor 4.�999 21 8 8 182.0 ft= 0 0.600000 0 i _ 5 N=>NE Garage Frame-Wood 1st Floor 11 21 4 8 8 184.9 ft2 0 0.01 0 � _6 E=>SE Garage Frame-Wood 1st Floor 11 2 8 8 17.3 ftZ 0 0.01 0 _7 W=>NW Garage Frame-Wood 1 st Floor 11 18 6 8 8 160.3 ftz 0 0.01 0 _ 8 N=>NE Exterior Frame-Wood 2nd Floor 11 21 4 8 170.7 ft2 0 0.600000 0 � i 9 N=>NE Exterior Frame-Wood 2nd Floor 11 8 8 8 69.3 ft2 0 0.600000 0 10 E=>SE Exterior Frame-Wood 2nd Floor 11 19 6 8 156.0 ftz 0 0.600000 0 � 11 E=>SE Exterior Frame-Wood 2nd Floor 11 22 6 8 150.0 ftz 0 0.600000 0 _12 S=>SW Exterior Frame-Wood 2nd Floor 11 30 8 240.0 ft� 0 0.600000 0 13 W=>NW Exterior Frame-Wood 2nd Floor 11 42 8 336.0 ft2 0 0.600000 0 ' 14 S=>SW Exterior Concrete Block-Int Insul 1 st Floor 4.�999 6 8 8 52.0 ft2 0 0.600000 0 I DOORS I # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated 1st Floor None .2 3 6 S 20 ft2 2 N=>NE Wood 1st Floor None .4 2 8 6 8 17.8 ftz , WINDOWS ' Orientation shown is the entered orientation(_>)changed to Worst Case. � � Wall Overhang i # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening � 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 8.8 ftz 4 ft 4 in 0 ft 1 in Drapes/blinds None I 2 E=>SE 2 Metal Low-E Double Yes 0.54 0.31 16.0 ft� 1 ft 0 in 10 ft 4 in Drapes/blinds None i 3 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 23.0 ft' 1 ft 0 in 10 ft 4 in Drapes/blinds None I 4 S=>SW 14 Metal Low-E Double Yes 0.56 � 0.32 33.3 ft2 2 ft 0 in 0 ft 10 in Drapes/blinds None � 5 N=>NE 8 Metal Low-E Double Yes 0.56 0.28 32.0 ftZ 1 ft 0 in 3 ft 2 in Drapes/blinds None � 6 N=>NE 8 Metal Low-E Double Yes 0.56 0.28 8.8 ftz 1 ft 0 in 0 ft 4 in Drapes/blinds None 1 7 E=>SE 11 Metal Low-E Double Yes 0.54 0.31 16.0 ftz 1 ft 0 in 0 ft 4 in Drapes/blinds None ; 8 S=>SW 12 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 1 ft 0 in 0 ft 4 in Drapes/blinds None � 9 W=>NW 13 Metal Low-E Double Yes 0.54 0.31 16.0 ftz 1 ft 0 in 0 ft 4 in Drapes/blinds None I i � i � I , I � i 5/30/2017 1�44 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 � , , I , . , ; FORM R405-2014 � � GARAGE I # FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation ' i 1 443 ft2 443 ft2 48 ft 8.6 ft 1 INFILTRATION � # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .OD�367 1799.9 98.81 185.83 .3388 7 � � HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts � 1 Electric Heat Pump None HSPF:8.5 32.8 kBtu/hr 1 sys#1 � COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts � I 1 Central Unit Split SEER:15 34.2 kBtu/hr 1026 cfm 0.85 1 sys#1 ' HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None j SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftZ � i DUCTS � J / —Supply-- ---Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool a 1 Attic 6 374 ft2 2nd Floor 93.5 ftZ Prop.Leak Free 2nd Floor —cfm 56.1 cfm 0.03 0.60 1 1 � I � _ i i , I � I � 5/30/2017 1 44 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 � FORM R405-2014 • � " TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin [ ]Jan [ ]Feb ]Mar [ ]A r [ ]Ma �X]Jun [X]Jul ]Au �X]Se [ ]Oct [ ]Nov [ ]Dec I Heatin9 [X]Jan [X]Feb EX]Mar f ]Apr [ ]May [ ]Jun [ ]Jul (�]Aug [ ]SeP [ ]Oct [X]Nov [X]Dec � Ventin [ ]Jan [ ]Feb [X]Mar [X]A r [ ]Ma [ ]Jun [ ]Jul [ ]Au [ ]se [x]oct [x]Nov [ 1 Dec I i Thermostat Schedule: HERS 2006 Reference Hours i Schedule Type 1 2 3 4 5 6 7 8 9 1� 11 12 I Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 � PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 I PM 78 78 78 78 78 78 78 78 78 78 78 78 � Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 � PM 68 68 68 68 68 68 68 68 68 68 66 66 ; Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 , PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION I Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 1 -Electric Heat Pump 0% 1 -Central Unit i I _ � � i I � - i I � , � I i I � I I I I � 5/30/2017 1�44 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 � I 1 � � � I " 7 FORM R405-2014 ' ENERGY PERFORMANCE LEVEL (EPL) , � DISPLAY CARD ; � ESTIMATED ENERGY PERFORMANCE INDEX* = 97 ' The lower the EnergyPerFormance Index,the more efficient the home. � � „ F�, � 1 New construction or existing New(From Plans) 9. Wall Types Insulation Area I � 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1152.00 ft2 � b.Concrete Block-Int Insul,Exterior R=4 1 846.44 ftz 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 362.56 ft' 4 Number of Bedrooms 4 d.N/A R= ft' � 5. Is this a worst cese? Yes 10.Ceiling Types Insulation Area I a.Under Attic(Vented) R=30.0 1090.00 ftz 6. Conditioned floor area(ftZ) 1870 b.N/A R= ft' � 7 Windows** Description Area c.N/A R= ft2 ; a. U-Factor Dbl,U=0.54 87 00 ft� 11 Ducts R ftZ � a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 374 SHGC: SHGC=0.31 - b. U-Factor Dbl,U=0.56 49.69 ft2 SHGC: SHGC=0.28 12.Cooling systems kBtu/hr Efficiency c. U-Factor Dbl,U=0.56 33.33 ftZ a.Central Unit 34.2 SEER:15.00 I SHGC: SHGC=0.32 � d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency � SHGC: a.Electric Heat Pump 32.8 HSPF:8.50 ' Area Weighted Average Overhang Depth: 1.369 ft. Area Weighted Average SHGC: 0.303 8. Floor Types Insulation Area 14 Hot water systems i z a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 780.00 ft EF 0.95 b.Floor Over Other Space R=0.0 647.00 ft2 ; c.other(see details) R= 443.00 ftZ b. Conservation features , None 15.Credits Pstat , i_ I certify that this home has complied with the Florida Energy Efficiency Code for Building � �� � Construction through the above energy saving features which will be installed (or exceeded) C+'��� �A�'� 1 in this home before final inspection. Otherwise, a new EPL Display Card will be completed �''�`�" �:';'` �";s,, r {y} � ' ' a� ,�e �� r •�•^<•>`fi+'�5�k` ` based on installed Code compliantfeatures. � dtJdt, .f�4•;�:=�;,r�,; L5 � .. �� :: -.. . ., �s Builder Signature. Date. 05/31/17 � ?��s�°� '�� � * .�.n . �, i Address of New Home. 36060 Stable Wilk Avenue City/FL Zip.Ze�hyrhills,FL 33541 �!� '��s`�` . � �'[t:�fi�`. *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For � information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. i **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I 5/30/2017 1:46 PM EnergyGauge�USA-FlaRes2014 -Section R405.4 1 Compliant Software Page 1 of 1 , , ' �� • . ; Buildin Anal S�S Job: 1871 sf ADS � � � Date: 5l30/2077 Entire House By: Dave , Bayonet Plumbing Heating &Air , ; , � � ' s - e s � For: Lennar Homes _ I � - e • o e I Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16� Latitude: 28°N Relative humidity(%) 50 50 � ' Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7 �` Dry bulb(°F) 31 91 Infiltration: � • Daily.range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 ! a � Component Btuh/ft2 Btuh % of load �� Walls 4 6 9527 33.8 ��s i Glazing 30.2 5013 17.8 � DOOrS 23.5 466 1.7 wans Cellings 1.5 1826 6.5. �e�trat�o� I Floors 4.9 3835 13.6 � Infiltration 19 4331 15.4 D ucts 3214 11.4 � Piping 0 0 F�oo�s Humidification � � Glazing � Ceilings � Ventilation 0 0 Other , Adjustments 0 � � Total 28211 100.0 � � . a s � Component Btuh/ft� Btuh % of load Walls 2.8 5659 211 Glazing 47.2 7831 29.2 Walls Intemal Gains i Doors 18.4 365 1.4 Ceilings 1.9 2408 9 0 Floors � 0.0 7 0.0 Infiltration 0.4 953 3.6 � � D ucts 3608 13.4 Ventilation 0 0 - oucts Internal gains 6010 22.4 _ ; - BIOWe� 0 0 Glazing Infiltration � Adjustments 0 Ceilings Totdl 26841 100.0 Other Latent Cooling Load=4018 Btuh Overall U-value= 0.123 Btuh/ftZ=F Data entries checked. � ,�, wri htsoft` 2017-May-3014:36:51 - � 9 Right-SuRe�Universal 2017 17.0.23 RSU05714 Page 1 ...with CBA27UHE AH's11871B sf ADS drawn 3ton.rup Calc=MJ8 Front Door faces: N . � , � i Pro ect Summa Jo6: 1871 sf ADS I i � � Date: 5I30/2017 Entire House By: Dave Bayonet Plumbing Heating 8�Air ' ' • - • • For Lennar Homes � Notes: � � - e o o � I Weather: Tampa InternationalAP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F ` Inside db 70 °F Inside db 75 °F � Design TD 39 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 55 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing ' Structure 24998 Btuh Structure 23233 Btuh Ducts 3214 Btuh Ducts 3608 Btuh � Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh , (none) (none) Humidification 0 Btuh Blower 0 Btuh , Piping 0 Btuh , Equipment load 28211 Btuh Use manufacturer's data y , Rate/swing multiplier 1.00 Infllt�atlon Equipment sensible load 26841 Btuh � i Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 3378 Btuh Ducts 640 Btuh Central vent (0 cfm) 0 Btuh ; , Heating Cooling (none) Area(ftz) 1870 1870 Equipment latent load 4018 Btuh � i Volume(ft') 17729 17729 ! Air changes/hour 0.34 0.18 Equipment Total Load (Sen+Lat) 30858 Btuh ', Equiv.AVF (cfm) 100 53 Req. total capacity at 0.85 SHR 2.6 ton i Heating Equipment Summary Cooling Equipment Summary � Make Lennox Make Lennox I Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-036-230-21 Cond 14HPX-036-230-21 � AHRI ref 10258589 Coil CBA27UHE-036-230*++TDR AHRI ref 10258589 - Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER ' Heating mput Sensible cooling 29580 Btuh � Heating output 32800 Btuh @ 47°F Latent cooling 5220 Btuh � Temperature rise 25 °F Total cooling 34800 Btuh � Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.043 cfmfBtuh Air flow factor 0.045 cfm/Btuh � Static pressure 0 in H20 Static pressure 0 in H20 � Space thermostat Load sensible heat ratio 0.87 Capacity balance point=28 °F Backup: n/a n/a Input— 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-May-30 14:36:51 � wrightsoft� Rlght-Suite�Universal 2017 17.0.23 RSU05714 page 1 � with CBA27UHE AH's\1871B sf ADS drawn 3ton.rup Calc=MJS Front Door faces: N . . . . Manual S Compliance Report Job: 1871 sf ADS �� Date: 5/30/2017 Entire House By: Dave � Bayonet Plumbing Heating �Air ' s - s s ' For: Lennar Homes • o e • e Design Conditions Outdoor design DB 91.3°F Sensible gain: 26841 Btuh Entering coil DB 75.6°F Outdoor design WB. 77 3°F Latent gain: 4018 Btuh Entering coil WB� 62.8°F Indoor design DB: 75.0°F Total gain: 30858 Btuh Indoor RH� 50% Estimated airflow� 1200 cfm Manufacturer's Performance Data atActual Design Conditions Equipment type: SpIitASHP � �Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230*++TDR Actual airflow: 1200 cfm '� Sensible capacity: 29070 Btuh 108% of load Latent capacity: 4860 Btuh 121% of load Total capacity� 33930 Btuh 110% of load SHR. 86% , i I s � e � I Design Conditions Outdoor design DB 30.8°F Heat loss: 28211 Btuh Entering coil DB 69.7°F Indoor design DB. 70.0°F ' j i Manufacturer's Performance Data at Actual Design Conditions � Equipment type: SpIitASHP Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230*++TDR � Actual airtlow� 1200 cfm ' Output capacity: 32800 Btuh 116% of load Capacity balance: 28 �F ; Supplemental heat required: 0 Btuh Economic balance: -99 °F � Backup equipment type: Elec strip � Manufacturer n/a Model: n/a+n/a I Actual airtlow.: 1200 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 °F i Meets are all requirements of ACCA Manual S. � wri htsoft` _ 2017-May-30 14:36:51 �� 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 ' �� ...with CBA27UHE AH's\1871B sf ADS drdwn 3ton.rup Calc=MJS Front Door faces: N ,