HomeMy WebLinkAbout17-18654 CITY OF ZEPHYRHILLS
5335.-,8TH STREET . -
, � (s13)�so-oo2� � .� 1.8654
FI�E SPRINKLER SYSTEM PERMIT /` J I
' PERMIT INFORMATIOhI LOCATION�INFORMATION '
Permit Number: 18654 Address: 5939 GALL BLVD
Permit Type: FIRE SPRINKLER SYSTEM ZEPHYRHILLS, FL.
Class of Work: FIRE-SPRINKLER SYS Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Square Feet: Subdivision: CITY OF ZEPHYRHILLS
Est. Value: Parcel Number: 10-26-21-0020-00000-0050
Improv. Cost: 27,600.00 OWNER INFORMATION
� Date Issued: 7/28/2017 Name: ZEPHYR II LLC
Total Fees: 275.00 Address: 7162 READING RD STE 730
Amount Paid: 275.00 CINCINNATI, OH 45237-3845
Date Paid: 7/28/2017 Phone:
Work Desc: INSTALLATION FIRE SPRINKLER HABOR FREIGHT
CONTRACTOR S APPLICATION FEES
BENEFIICIAL FIRE PROTEC I N INC FIRE SPRINKLER SYS 50.00 FIRE PLAN REVIEW FEES 100.00
FIRE INSPECTION FEES 45.00 CONTRACTOR CERTIFICATE 30.00
FIRE RISER 50.00
I
� �
�' � /
�
Ins ections Re uired
FIRE-PRESSURE TEST
FIRE ACCEPTANCE Final �
Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire
prevention and protection related activities such as inspections, plan review,administrative fees,and other
costs related to the aforementioned.
Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of
the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final
inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All
work shall be performed in accordance with City Codes and Ordinances.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE �FOR
IMPROVEMEIVTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMEN ENT."
/�
ONTRACTOR SIGNATURE PERMIT OFFICE
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED
ZEPHYRHILLS FIRE RESCUE DEPT- 813-780-0041 ,
a�sa8o-ao2a City of Zephyrhills Fire Fax-813-780-0023
Permit Application
Date Received ' � ��� �—J i Phone Confact.for Perm'it� j '' %���
�:"s.`_.=_....-.�."='r..e..�..:.._�.>_..,��..r`.>-_ ::...�,�">�-_=`_,.�..'""�.�_�...�:..ra..�:�«����:';.�:,:.,.=.�.__r�.-.,..__-�_...v.:...._�....,...-<a.._�,'",.,,L�L��yY:"',�;—.,,3�
<.... � �� ��
Qwne�s Name s Owner's Phone Number
Owner's Address `
Fee Simple 7itleholder Name Titleholder Phone Number � � ��
Fee Simple Titteholder Address `
.YT:ur.r?+'-)'wy.�•.rqp-.,..�„a'n fw,-;v..�.;_.�,.�_. 5� _ �M�.y,-;.r,+ 'eF1'�".� �y.�.�.Y,.a.} _ ..r-m _.. �i.�,.,`!��."-...r*'�.,>_ . ^�„SSnf�
::�:-,,...:..:_a..:,.,..� ..";..i..... _t� ,,..�--.-"!.i'.:��-.d.:. :.Y=� ....:.;:s,.�`a�'.... -�.:-��".ws..�.- rw,y�.+z':�;�:t:,_... .�::,.i="..�'�".�,.�,._..`-y''_i.'�`�-m,:C:.�'�......z..'�'��'...���r'�:i,-�;;::z.�
Job Address � Cy'"/`f L` !.� Lot# z �
Sub Division Parcel# �"�� 2�'-v[/'�"'U.�/p'
f'�.:35`c,.���'.:w�:..`.°s,».�:.,.._"",,,i.:�.',':S'��„-��:.:-."ww."�,.�-'.c."r::e.:.:"`.:a.':'x.a"::2.':"'�a.....�,��..M.`.:':..;:%;_:`�.;L:.�'�"'"xa.�c<:iM:"�.._.e........::`�:L.�.:�1.'�"'1:...a._.u......W.,..s.�..w.,,.�._,,...,..R"`7.��::.v.r+�,=,�:;�"T�'�..,,��;�`,'j"A`.�r�._'-.,"^.x:d.._':..�.'�"yw'-;�:�'.9:
� Bio-Hazard Waste Storage-ANNUAL � Fumigation Tent �
� Comm Exhaust Kitchen HoodlDuct � Hazardous{Naterial(Tier II ar R{1 Facility}ANNUAL
„ � Controlled Bum o Haod Installation _
� Emergency Generator<30 kw Q LP/Naturai Gas-tnstaliation ti � , i
C.� 9 Y 0 ��„ ��� j"�,.�,
Emer enc Generator>30 kw l.P/Natural Gas-ANI�UAL 8ale
� Fire Proteotion Maintenance-ANRtUAL Q Piaces of Assemb(y ANNUAL
Ifr y em � er
Sprinkler � C] I� C} � Recreafional Bum
Fire Alarm � ❑ Cl ❑ � �5pa��~��
Nood Cleaning � Cf , � ❑ �.�� Sprinkler System MstaHatians W jUl r�+r I"f 2� G/ ��
Hoad Suppression � ❑ ❑ ❑ ---��Siandpipes{S�r�nklerSYsj ��— �-
�;�����--
� Fire Alarm installation Q 7oroh Roofingtfar Kettie � � ?. �rl -
� Fire Pumps o Waste Tire Storage ANNUAL �� ^7,�'���wv�+—,
� Fiammabie Appiication-ANIdUAL T
r�(vpt�r t� Va uation of Praject
� Fuei Tanks � ��C'"
Q dther: i
�.,_.._.._....,�,_.--�-.._r..�._.�.-,m:.<--..-.��.,:.,,:m- - �w� � �.�-.�;:--n<�
e�;�..3::�._;...�;;�,���.�.�� ., .._�, �.. �,-,:�r�,.., �..�r��_-�-_ _..�.�,... �,.��.�::;.�;:.�.�::.{..�,,.��::.:�.�.^—' . ....._. - �:.:���- .�e�
___� ,�.x��-'..w.�.
Contraetor (-�� Company '"� f�lfj} ! /`�dj '"� .+G.3
Signature Registered Y/N Fee Current Y/N
Address `� � � � / �j4� � , ttll� !l�Nd J�3G�'license# � . l� j�il��
ELECTRICIAN ` �!""Gompany
Signature Registered -Y/RI Fee Currenf Y/1�1 .
Address License#
PLUMBER Company
Signature Registered Y/N Fee Current Y/N
Address �icense#
tNEGFiANiGAL Company
Signature • Registered Y/N Fee Current Y I N
Address License#
OTHER Company
Signature Registered Y/N Fee Current Y/N
Address License#
��----.��..,;.__- - , _, .. _ - - - - _ _
::,..,�,�.�.�<.,.��.-�,�;:�.:.:s�,�x.- :v. --_ -,. _.�.'.�.,.w:_�,......,_._.._.�.._.._.._..,.�.r_.�......�_�.,__..�,ti.,,...,._-.>.�. ..�___�.v._,:by<x._�.---._....__,...._a.....,t.._:.d:..�_,�s�__�.__.._.
pirectiarrs: vr..r..a .�..��ti.,�.�.___._�..�:��
Fill out application completely.
Owner&Contractor sign back of application,notarized(Or,capy of signed contract with owner)
If over$2600,a Nof'sce of Commencement is required{Mechanical work over$5044}
8upply twa(2)sats of drawings with applicable documentation .,.. ,.
Allow 10-14 days for review after submittal date. Parcel#-obtained from Property Ta�c Notice(http://appraiser.pascogov.com)
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed°restrictions°
which may be more restrictive than County regulations. The undersigned assumes responsibllity for campliance with any
applicable deed restrictions. � �-
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or �
contractors to undertake work,they may be required to be Ifcensed In accordance with state and local regulations. If the
contractor is not licensed as required by iaw, both the ovmer and contractor may be clted for a mfsdemeanor violatlon
under state law. If the owner or Intended contractor are uncerta(n as to what Iicensing requfrements may apply for the
intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- �
8009.- �urthermore, ff the owner has hired a contractor or contractors, he is advised to have the corttractor(s) sign
portions of the"contractor Block°of this application for which they will be responslble. If you,as the owner sign as the
contractor,that may be an indication that he Is not properly Iicensed and Is not enBUed to permitting privileges in Pasw •
County. • • `
TRANSPORTATION IMPACTNTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of
use in existing buildings,or expansion of existing bulldings,as spec�ed in Pasco County Ordinance number 89-07 and
90-07,as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of
permitting. It is further understood that TransportaUon lmpact Fees a�d Resource Recovery Fees must be paid prior to
re�eiving a'certificate of occupancy°or flnal power release. If the project does not involve a certificate of occupancy or
final power release,the fees must be paid prior to'permit(ssuance. Furthermore,ff Pasco County Water/Sewer Impact
fees are due,they must be pald prior to permit Issuance in accordance wlth apPlicable Pasco County ordinances.
CONSTRUCTION LIEM LAW(Chapter 713,Florlda Statutes,as amended): If valuaUon of work is$2,500.00 or more,t �
certify that 1, the applicant, have been provided with a copy of the 'Florida Constrvction Lien Law—Homeowners
Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the appiicant is someone
othe'r than the'owner°,I certify that I have obtained a copy of the above described document and promise in good faith to --
deliver R to the`owner"prior to commencement.
CON7RACTOR'SIOWPIER'S AFFIDAVIT: i cerUfy that all ihe Informatfon In this application is accurate and that all work
will'be done in compliance with all applicable laws regulating construction,zoning and land development. Application is �
hereby made io abtain a permit to do work and Installation as indicated. I cerlffy tha,t no work ar InstallaUon has
commenced prior to issuance of a permft and that all work will be perFortned to meet standards of all laws regulat(ng
construction, County and City codes, zoning regulatlons, and larid`development regulations in the jurisdiction. I also
certtfy that I understand that the regulations of otFier govemment agencles may apply to the intended work,and that it is
my responsibility to identify what acttons I must take to be in compliance. Such agencies fnclude but are not limfted to:
- Department of Environmental Protect'ion-Cypress Bayheads, Wetland Areas and Environmentally Sen'sitive
Lands,Water/Wastewater Treatment �
- SouihwesE Fiorida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses. •
- Army Corps of Engineers-Seawalis,Docks,Navtgable Waterways.
- Department of Health & Rehabllitetive Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks. .
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviaiion Authority-Rurmrays. -
I understand that the following resMctions appiy to the use of flll:�
- Use of fill is not alldwed in Flood Zone N"unless expressly permltted.
- If the flll material is to be used in Flood Zone °A°, It Is understood that a drainage plan addressing a
°compensating volume"will be submttted at flme of permitting wFiich is prepared by a professional engineer , •
- licensed by the State of Florida.
- If ih�flll material (s to be used in Flood Zone'A° irt wnnection with a permitted building using stem wall
construotion,I certify that fill wlll be used only to flll the area within the stem wall.
- If flll material is io be used In any erea, I certlfy that use of such fill will not adversely affect adJacent
Prapertles. If use of fll is found to adversely affect adJacent properties,the owner may be c(ted for violating
the conditlons of the building.pertnit Issued underthe attached pertnft application,for lots less than one(1)
acre whlch are elevated by flll,an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER,I promise In good fafth to inform the owner of,the pertnitting conditions set forth in
this affidavit prior to commen�ing construction. I understand that a separate permlt may be required for electrical work,
plumbing, signs,wells, pools, afr condflioning, gas, or other Installations not specffically included in the applicatton. A
= permft issued shall be construed to be a Ifcense to proceed with the work and not as authority to.violate,cancel,alter,or
set eside any provisions of the technical codes,nor shall issuance of a permit prevent the Bulldirig Officlal from thereafter
requiring a correction of errors in plans,construction or violaUons of any codes. Every permit Issued shall beaome invalfd
unless the work authorized by.such permit is commenced withln six mordhs of permit Issuance,or ff work authorized by
ihe permit fs suspended or abandoned for a period�of�six(6)months aiter the time the work is commenced: M extension
may be requested, in writing,from the Building.Official for a period not to exceed ninety(90)days and will demonstrate
Justifiable cause for the extens(on. if work ceases for,ninety(90)consecutive days,th\job is considered abandoned. .
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR "
PAYING 7WICE FOR IMPROVEMEWTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CO� SULT
WITH YOUR LENDER R AN O BEFO E CORDING YOU OTiCE CO CEMENT
FI.ORIDA JURAT(F:S.117. �,�s ' �,
OWNER OR AGENT ` �v SCONTR/1CT0 �
Su l ed�t�Ty/m�/�"i/�/`l�Nb/c-( /7/T�'�LOGLG /—fs b<7 nd svwm : , � e��ef��e/`this CO��
WhoJsla�q pe�s o�a ly Icrwwn to me or hasfiave produced Who Is/are erso al cno to me or haslF�ave produced
FL. }J([((�'rJ(��t� asidentlfiptlo�. � /�'�'S�t ,� asidentlfication.
� "t-� Notary Pubtic �--e+ otary Pub11c
m�ss o. -. com � n, ��eG'•. JAC(5� LINE BOGES
_���� ;#;' •;._ ommission
Name oi No d tln����'�9 �� �Name of • •� o�dob �� N,�rence BOD3E5-1019
�wt � Gamp�s D�o��n��r 12,�019 �-�.r,e�•'
�m^' � �a�d9dtp�t��@�inlhcurenAdB003B54d�9
�ii u,` �
- ' �
Beneficial Fire Protection ' - Page 1
HARBOR FREIGHT TOOLS Date 062317
Hydraulic Desiqn Information Sheet
Name - Harbor Freight Tools Date - 6-23-17
Location - 5935 Gall Blvd. Zephyrhills, FL
Building - System No. -
Contractor - Beneficial Fire Protection, Inc. Contract No. -
Calculated By - SG Drawing No. - FP-1
Construction: ( ) Combustible (X) Non-Combustible Ceiling Height - Varies
Occupancy - Ordinary Hazard II
S (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. ( ) 1 (X) 2 ( ) 3 ( ) Ex.Haz.
Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve
S Other
T Specific Ruling Made By Date
E
M Area of Sprinkler Operation - 1598 SF System Type Sprinkler/Nozzle
Density - .20 (X) Wet Make Globe
D Area Per Sprinkler - ( ) Dry Model GL8118
E Elevation at Highest Outlet - 17.830 ( ) Deluge Size 3/4
S Hose Allowance - Inside - 0 ( ) Preaction K-Factor 8.1
I Rack Sprinkler Allowance - ( ) Other Temp.Rat.155
G Hose Allowance - Outside - 250
N
Note
Calculation Flow Required - 601.36 Press Required - 44.20 Riser
Summary C-Factor Used: 120 Overhead 150 Underground
W Water Flow Test: Pump Data: Tank or Reservoir:
A Date of Test - 6-13-17 Cap. -
T Time of Test - 1:29 PM Rated Cap.- Elev.-
E Static Press - 65 @ Press -
R Residual Press - 55 Elev. - Well
Flow - 1025 Proof Flow
S Elevation - 0
U
P Location - Behind new Harbor Freight Tools (No. 1003)
P
L Source of Information - Zephyhills Water Dept.
Y
C Commodity Class Location
0 Storage Ht. Area Aisle W.
M Storage Method: Solid Piled o Palletized o Rack
M
( ) Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap.
S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non
T A ( ) Mult. Row ( ) Open Shelf
O C �
R K Flue Spacing Clearance:Storage to Ceiling
A Longitudinal Transverse
G
E Horizontal Barriers Provided:
��g�g,������/f��,y j
A C'�}%
p9 Ja;,
�r I
.�.e����,�°�� �.�c���a�.�����e ���TB����0������� ��R����9�FL�
�
������6�
:� o � h� ,3 '�� ��• ��R����,CU�`TI�9 P.�s
"'� a a
mm ' G���3�9�2 �I
� ` °, ° �d .�9 �977� �AYHEA� ROA�
w
���°�,.� �a,-''�'�. �����V�S FQ.3�'���
���''������a� �t������4a
����3��� ��,�u',���.• --
Final Calculations - Hazen-Williams • • . • I
Beneficial Fire Protection ' • Page 5 I
HARBOR FREIGHT TOOLS Date 062317
Hyd. Qa Dia. Fitting Pipe Pt Pt ,
Ref. "C" or Ftng's Pe Pv **''*""'* Notes '''''"** '
Point Qt Pf/Ft Eqv. Ln. Total Pf Pn �
D001 26.00 1.049 T 5.0 0.500 10.303 K Factor=8.10
to 120.0 0.0 5.000 0.0
EQ01 26.0 0.2115 0.0 5.500 1.163 Vel = 9.65
0.0
26.00 11.466 K Factor= 7.68
20 -65.96 1.728 T 11.29 57.540 19.058
to 120.0 0.0 11.290 0.0
1 A -65.96 -0.1041 0.0 68.830 -7.165 Vel = 9.02
1 A 26.48 1.728 0.0 9.330 11.893 K Factor @ node EQ01 '
to 120.0 0.0 0.0 0.0
1 B -39.48 -0.0403 0.0 9.330 -0.376 Vel = 5.40 I
1 B 26.06 1 J28 0.0 9.330 11.517 K Factor @ node EQ01 �
to 120.0 0.0 0.0 0.0
1 C -13.42 -0.0055 0.0 9.330 -0.051 Vel = 1.84
1 C 26.00 1.728 0.0 9.330 11.466 K Factor @ node EC101
� to 120.0 0.0 0.0 0.0
1 D 12.58 0.0049 0.0 9.330 0.046 Vel = 1.72
1 D 26.05 1.728 0.0 9.330 11.512 K Factor @ node EQ01
to 120.0 0.0 0.0 0.0
1 E 38.63 0.0386 0.0 9.330 0.360 Vel = 5.28
1 E 26.46 1.728 0.0 9.330 11.872 K Factor�a node EQ01
to 120.0 0.0 0.0 0.0
1 F 65.09 0.1016 0.0 9.330 0.948 Vel = 8.90
1 F 27.49 1.728 T 11.29 58.250 12.820 K Factor @ node EQ01
to 120.0 0.0 11.290 0.0
30 92.58 0.1949 0.0 69.540 13.556 Vel = 12.67
0.0
92.58 26.376 K Factor= 18.03
*P-3
21 -66.11 1.728 T 11.29 57.540 19.116 '
to 120.0 0.0 11.290 0.0
1 G -66.11 -0.1045 0.0 68.830 -7.195 Vel = 9.04
1 G 26.51 1.728 0.0 9.330 11.921 K Factor @ node EQ01
to 120.0 0.0 0.0 0.0
1 H -39.6 -0.0405 0.0 9.330 -0.378 Vel = 5.42
1 H 26.09 1.728 0.0 9.330 11.543 K Factor @ node EQ01
to 120.0 0.0 0.0 0.0
1 I -13.51 -0.0055 0.0 9.330 -0.051 Vel = 1.85
1 I 26.03 1.728 0.0 9.330 11.492 K Factor Qa node EQ01
to 120.0 0.0 0.0 0.0
1 J 12.52 0.0047 0.0 9.330 0.044 Vel = 1.71
1 J 26.08 1.728 0.0 9.330 11.536 K Factor @ node EQ01
to 120.0 0.0 0.0 0.0
1 K 38.6 0.0387 0.0 9.330 0.361 Vel = 5.28
1 K 26.48 1.728 0.0 9.330 11.897 K Factor @ node EQ01
to 120.0 0.0 0.0 0.0
1 L 65.08 0.1016 0.0 9.330 0.948 Vel = 8.90
1 L 27.52 1.728 T 11.29 58.250 12.845 K Factor @ node EQ01
to 120.0 0.0 11.290 0.0
31 92.6 0.1950 0.0 69.540 13.561 Vel = 12.67
Computer Programs by Hydratec Inc. Route 111 Windham N H. USA 03087
I
Final Calculations - Hazen-Williams • � , •
Beneficial Fire Protection ' • Page 6
HARBOR FREIGHT TOOLS Date 062317
Hyd. Qa Dia. Fitting Pipe Pt Pt
Ref. "C" or Ftng's Pe Pv **""'*'`* Notes "'`*'`**
Point Qt Pf/Ft Eqv. Ln. Total Pf Pn
0.0
92.60 26.406 K Factor= 18.02
"P-6
22 14.21 1.728 T 11.29 57.540 19.327
to 120.0 0.0 11.290 0.0
1 M 14.21 0.0061 0.0 68.830 0.418 Vel = 1.94
1 M 34.12 1.728 T 11.29 104.330 19.745 K Factor @ node EQ01
to 120.0 0.0 11.290 0.0
32 48.33 0.0586 0.0 115.620 6.770 Vel = 6.61
0.0
48.33 26.515 K Factor= 9.39
'P-7 i
23 38.76 1.728 2T 22.58 162.000 19.497
to 120.0 0.0 22.580 0.0
' 33 38.76 0.0389 0.0 184.580 7.186 Vel = 5.30
0.0
38.76 26.683 K Factor= 7.50
*P-8
24 39.17 1.728 2T 22.58 162.000 19.578
to 120.0 0.0 22.580 0.0
34 39.17 0.0397 0.0 184.580 7.328 Vel = 5.36
0.0
39.17 26.906 K Factor= 7.55
I * -
P9
25 39.92 1.728 2T 22.58 162.000 19.601
to 120.0 0.0 22.580 0.0
I 35 39.92 0.0411 0.0 184.580 7.591 Vel = 5.46
0.0
39.92 27.192 K Factor= 7.66
*P-10
20 65.96 3.314 0.0 13.330 19.058
to 120.0 0.0 0.0 0.0
21 65.96 0.0044 0.0 13.330 0.058 Vel = 2.45
21 66.10 3.314 0.0 13.330 19.116
to 120.0 0.0 0.0 0.0
22 132.06 0.0158 0.0 13.330 0.211 Vel = 4.91
22 -14.20 3.314 0.0 13.330 19.327
to 120.0 0.0 0.0 0.0
23 117.86 0.0128 0.0 13.330 0.170 Vel = 4.38
23 -38.77 3.314 0 0 13.330 19.497
to 120.0 0.0 0.0 0.0
24 79.09 0.0061 0.0 13.330 0.081 Vel = 2.94
24 -39.17 3.314 0.0 13.330 19.578
to 120.0 0.0 0.0 0.0
25 39.92 0.0017 0.0 13.330 0.023 Vel = 1.48
0.0
39.92 19.601 K Factor= 9.02
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087
I
Final Calculations - Hazen-Williams • • : -
Beneficial Fire Protection ' � Page 7
HARBOR FREIGHT TOOLS Date 062317
Hyd. Qa Dia. Fitting Pipe Pt Pt
Ref. "C" or Ftng's Pe Pv '****** Notes ""'*"
Point Qt Pf/Ft Eqv. Ln. Total Pf Pn
"P-12
30 92.58 4.31 0.0 13.330 26.376
to 120.0 0.0 0.0 0.0
31 92.58 0.0023 0.0 13.330 0.030 Vel = 2.04
31 92.60 4.31 0.0 13.330 26.406
to 120.0 0.0 0.0 0.0
32 185.18 0.0082 0.0 13.330 0.109 Vel = 4.07
32 48.33 4.31 0.0 13.330 26.515
to 120.0 0.0 0.0 0.0
33 233.51 0.0126 0.0 13.330 0.168 Vel = 5.14
33 38.76 4.31 0.0 13.330 26.683
to 120.0 0.0 0.0 0.0
34 272.27 0.0167 0.0 13.330 0.223 Vel = 5.99
34 3917 4.31 0.0 13.330 26.906
to 120.0 0.0 0.0 0.0
35 311.44 0.0215 0.0 13.330 0.286 Vel = 6.85
35 39.93 4.31 2E 27.874 14.500 27.192
to 120.0 0.0 27.874 0.0
TOR 351.37 0.0268 0.0 42.374 1.137 Vel = 7.73
00
351.37 28.329 K Factor= 66.02
*P-15
TOR 351.37 4.31 E 13.937 20.000 28.329
to 120.0 B 16.724 61.322 7.722
BOR 351.37 0.0268 S 30.661 81.322 2.181 Vel = 7.73
0.0
351.37 38.232 K Factor= 56.83
"P-18
BOR 351.37 6.09 3E 64.749 49.000 38.232
to 150.0 0.0 64.749 -1.299
BFD 351.37 0.0033 0.0 113.749 0.374 Vel = 3.87
BFD 0.0 6.09 E 21.583 6.000 37.307
to 150.0 K 55.499 77.082 6.299 * * Fixed Loss =5
BFS 351.37 0.0033 0.0 83.082 0.274 Vel = 3.87
BFS 0.0 6.09 E 21.583 6.000 43.880
to 150.0 G 4.625 72.457 0.0
UG1 351.37 0.0033 T 46.249 78.457 0.259 Vel = 3.87
UG1 0.0 8.27 E 28.468 45.000 44.139
to 140.0 0.0 28.468 0.0
SRCE 351.37 0.0008 0.0 73.468 0.062 Vel = 2.10
250.00 Qa= 250.00
601.37 44.201 K Factor= 90.45 I
Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 ,
J
r
SUBMITTAL DATA FOR:
HARBOR FREIGHT TOOLS
s�j 3�j ��135'GALL BLVD.
ZEPHYRHILLS, FLORIDA
JUNE 23, 2017
BENEFICIAL FIRE PROTECTION, INC.
12522 US Highway 301 N. Suite 1
Thonotosassa, Florida 33592
Phone: (813) 98G-5819
Fax: (813) 98G-5837
State Certificarion: #45018800011989
State Certification: #G7451300012005
INDEX
SPRINKLER HEADS:
Globe 1/z" QR 200° Brass Upright GL8118—8.1 K-Factor
PIPE:
Black Thinwall Piping
Black Schedule 40 Pipe
VALVES:
Riser Check Valve
Globe Valve
Angle Valve
Butterfly Control Valve
FITTINGS:
Threaded Fittings
Grooved Fittings
Welded Fittings
MISC:
Hanger Rings
Hanger Fasteners
Electric Bell
Flow Switch
.
. � � ' � • Ga(l1CK R�SP011oSE
...�
� ' AUTOMATIC SPRINKLERS
"" GL SERIES
----
"" UPRIGHT• PENDENT
FIRE SPRINKLER CORPORATIOf� VERTICAL SIDEWi4LL
HOR/ZONTAL SIDEWALL
CONVENTIONAL (OLD STYLE)
DESCRIPTION AND OPERATION
The Globe Quick Response GL Series Sprinklers are a low profile
yet durable design which utilizes a 3mm frangible glass ampule as the
thermosensitive element. This provides sprinkler operation approxi-
mately six times faster than ordinary sprinklers. While the Quick �,�� ,'`- -, u;-=���
Response Sprinkler provides an aesthetically pleasing appearance, it ` ��V�'
can be installed wherever standard spray sprinklers are specified when � � "
allowed b y the a p plicable standards. It offers the additional feature of � ,
g r e a t l y i n c r e a s e d s a f e t y t o l i f e a n d i s a v a i l a b l e i n v a r i o u s s t y l e s,o r i f i c e s, - � _
tem erature ratin s and finishes to meet man va in desi n re uire- ""� �" -
P 9 Y rY 9 9 q I_--- .�
ments. Quick Response Sprinklers should be used advisedly and under �'��
the direction of approving authorities having jurisdiction.
The heart of Globe's GL Series sprinkler proven actuating QUICK RESPOtVSE
assembly is a hermetically sealed frangible glass ampule that contains UPRIGHT CONVENTIONAL
a precisely measured amount of fluid. When heat is absorbed,the liquid
within the bulb expands increasing the internal pressure. At the �' � '��
prescribedtemperaturethe internal pressurewithin the ampuleexceeds
the strength of the glass causing the glass to shatter. This results in -�--- } ',
water discharge which is distributed in an approved pattern depending
upon the deflector style used.
The sprinkler and escutcheon are not factory assembled. As- '
sembly is done in the field .-.,,,,�-.,-• � ��� J
TECHNICAL DATA QUICK RESPONSE
•See reverse side for Approvals and Specifications. PENDENT VERTICAL
SIDEWALL
•Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C),
200°F (93°C), 286°F (141°C).
•Water Working Pressure Rating - 175 psi (12 Bars). �-:. - s
• Factory tested hydrostatically to 500 psi (34 Bars). ��� � t. �., ;
•Maximum low temperature glass bulb rating is -67°F (-55°C). �'` �; • !
• Frame - bronze • Deflector- brass • Screw - brass >
� Bulb seat- copper • Spring - nickel alloy • Seal - teflon (�UICK RESPONSE
• Bulb - glass with alcohol based solution, 3mm size.
HORIZONTAL SIDEWALL
• SPR/NKLER TEMPERATURE RATING/CLASSIFICATIOIY and COLOR CODING
CLASSIFICATION AVAILABLE SPRINKLER BULB N.F.P.A.MAXIMUM
TEMPERATURES COLOR CEILING TEMPERATURE
ORDINARY 135°F/155°F 57°C/68°C � ORANGE/RED 100°F 38°C
INTERMEDIATE 175°F/200°F 79°C/93°C iYELLOW/GREEN 150°F 66°C
HIGH 286°F 141°C � BLUE 225°F 107°C
4077AIRPARKDRIVE,STANDISH,MICHIGAN 48658 989-846�583 • FAX989-846-9231
DECEMBER 2006 A-20 BULLETIN GL5615, REV. #6
• A . . . .
QUIC�C RESPOIV$E ' •
AUTOMATIC SPR/NKLERS
GL SERIES
UPRIGHT• PENDENT• VERTICAL S/DEWALL
HORIZONTAL SIDEWi4LL • CONVENTIONAL (OLD STYLE�
SPECIFI CATIONS
NOMINAL"K" FACTOR THREAD SIZE LENGTH ' FINISHES
2.8 (39 metric) 1/2" NPT 2 1/4" (5.7 cm) Factory Bronze
4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm) Satin Chrome z
Bright Chrome
5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm) �ite Polyester3
7.8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm) Black Polyester 3
8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) Lead Coated z
NOTE. METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9/16"
z FINISHES AVAILABLE ON SPECIAL ORDER.
'AVAILABLEAS cULus LISTED CORROSION
APPROV�4LS RESISTANT WHEN SPECIFIED ON ORDER.
SME SIN K 135°F 155°F 175°F 200°F 286°F NYC-DOB
MODEL FACTOR 57°C 68°C 79°C 93°C 141°C cULus F.M. LPC CE MEA101-92-E
GL2815 2.8 X X X X X X — — — X
GL4215 4.2 X X X X X X — — — X
UPRIGHT GL5615 5.6 X X X X X X X X X X
GL8115 7.8* X X X X X X X — — X
GL8118 8.1 X X X X X X X X X X
GL2801 2.8 X X X X X X — — — X
GL4201 4.2 X X X X X X — — — X
PENDENT GL5601 5.6 X X X X X X X X X X
GL8101 7.8* X X X X X X X — — X
GL8106 8.1 X X X X X X X X X X
VERTICAL GL5632 5.6 X X X X X X X — — —
SIDEWALL GL8133 8.1 X X X X X X — — — —
GL2826 2.8 X X X X X X — — — X
HORIZONTAL GL4226 4.2 X X X X X X — — — X
SIDEWALL§ GL5626 5.6 X X X X X X X — — X
GL8127 8.1 X X X X X X — — — —
CONVENTIONAL GL5624 5.6 X X X X X — — X X —
(OLD SME) GL8125 8.1 X X X X X — — X X —
§HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4"TO 12"BELOW THE CEILING,FM APPROVED 4"TO 6"
t VERTICAL SIDEWALL SPRINKLER cULus LISTED FOR LIGHT HAZARD ONLY
PENDENT VERTICAL SIDEWALL cULus LISTED FOR 6'MIN.SPACING.
UPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9'MIN.SPACING.
ORDERING INFORMATION •��z��NPT
SPECIFY GLOBECR'PRODUCT WARRANTY
•Quantity • Model Number • Style Globe agrees to repair or replace any of its own
•Orifice • Thread Sizes m Temperature manufactured products found to be defective in mate-
�Finishes desired rial or workmanship for a period of one year from date
�Quantity-Wrenches - P/N 325390 (1/2"); of shipment.
P/N 312366 (L.O) For specific details of our warranty please refer to
Price List Terms and Conditions of Sale(Our Price List).
�� ��= �� 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658
�..� 989-846-4583 FAX 989-846-9231
FIRESPRItVKLERCORPORATION 1-800-248-0278 wwwglobesprinklercom
DECEMBER 2006 PRINTED U.S.A. BULLETIN GL5615, REV #6
, � • ° � :
• � ' � -
�
• Exceptional hydraulics e . .
• Lightweight and easy to NPS Nominal I.D. Wt. Wt.(H20 Filled) CRR
instal I In;mm In;mm Lbs/Ft;k /m Lbs/Ft;k /m Unthreaded
1" 1 191 0.830 131 2.41
• Available factory roil z5 30.3 �.z 1.95 —
grooved �'�"�� 1.536 1.059 1.87 1.55
32 39.0 1.6 2.78 —
i • ABFII coated ID ivz° i.�za 1.667 z.�� 3.44
UL and cUL listed 40 43.9 z.5 4.03 —
� 2" 2.203 2.104 3.79 2.78
• FM approved 50 56.0 3.1 5.64 —
2�h" 2.703 2.564 5.10 1.60
65 68.7 3.8 7.59 —
� The original high-strength 3" 3.314 3.387 �is i aa
, light wall sprinkler pipe 75 aa.z 5.0 10.69 —
with superior hydraulics. 4" 4.310 4.473 �o.s6 �o0
100 109.5 6.7 16.16 —
Dyna-Flow�-ABFII is the"original"
hi h-stren th li ht wall s rinkler i e. �L c �L F nn
9 9 9 P PP O OO
With outstandin h draulic ca abilities •Poa��Eo
9 Y P -
Dyna-Flow is recognized as the most � Superior Coating O American tVlade
popular alternative to Schedule-10 pipe. Able to meet"Buy American"requirements,
Lightweight and easy to cut,Dyna-Flow Dyna-Flow products are coated with an and is available through distributors in the
is a valuable addition to any fire environmentally approved and specially USA,Canada,Mexico and Latin America.
protection system. formulated modified-acrylic or water-based
coating This durable coating is paintable
With an inside diameter(ID)up to 11% and acts as an excellent primer while OO Specifications � Approvals
larger than Schedule-40 and up to 7% resisting weather and UV degradation Dyna-Flow pipe is manufactured to meet
larger than Schedule-10,Dyna-Flow from outdoor storage. ASTM A-795 Type E,Grade A and is in
pipe hydraulics are exceptional. compliance with NFPA-13 and NFPA-14
Larger ID's enable Dyna-Flow and related The internal surface of all black Allied Tube All sizes of Dyna-Flow are UL and cUL
components to be down-sized within the &Conduit Fire Sprinkler pipe products listed and FM approved
system,increasing the potential for job up to 4 500"in diameter is coated with
cost savings.For complete Hazen Williams our newAntibacterial Formula,"ABFII" Dyna-Flow is UL and cUL listed for use
charts,refer to "Dyna-Flow Hydraulic In scientific laboratory tests,ABFII proved with roll grooved, plain-end and welded
Data Tables" to have superior resistance to microbial joints for wet,dry,pre-action and deluge
colonization of pipe walls,thereby systems.It is FM approved for roll grooved,
Dyna-Flow pipe has metallurgical inhibiting or possibly preventing the onset plain end and weldetl joints for wet
properties that provide excellent of Microbiologically Influenced Corrosion systems.Dyna-Flow is available"hot-dip"
fabrication characteristics for end prep (MIC)upon installation and the first 25 galvanized**and has been specifically
finishes,welding and roll grooving. flushes of the fire spri�kler system.* approved by FM for dry system uses.
There are no special processes or Dyna-Flow complies with NFPA 13 and is
equipment needed for fabrication rated at 300 psi working pressure.
and installation
'See ABFII warranry
'*must be ordered in 10 bundle increments
��w III�^I Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com
Ll V •16100 5 Lathrop Ave. •11350 Norcom Rd. •2525 N 27th Ave. •600 Dean Sievers Place
TUBE&CONDUIT' Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009 Morrisville,PA 19067
0200&10 Tyco Int.,All Rights Reserved,STP-S2-3-1001
I
� �,.r� . , ... I
6
� a a o ,
D
p '
� � _ —_'—
�
�
T .c� 1e
�
TUBE& CONDUIT
' :�'�, .� i-
_ �,�� � !
"� �� � '
f:� � . ��� z� �w�. �
ii
'1 � r ��
� r �;y �*� '�h` �
� ,�'�t� ;�.,� � . ;� � �
`r s� ���, t.,
3 ; ��,s#
h �,i�.� } 't� ¢ Yr,�Y
' � 9 .��'� S'� _ � r��y� �f... � ,�'
� y„�'� .�'d�t �rFyy y�. '1� ' .
, � �"�{T �{" �4.� � �'` ���-c •!{� ,�,,,iLY�� t r
M�y`�
' �i Y '# i� �' R x� '`.F.
,� ���� �
� k�9E'�v.�- y t�'- � .N� �F
� '( � 6
�, ���j '` �:'�� � �� �`�,�'��
�
E ��.�'
�"� k *{..};.��:..
. ' , ' ��#����' f .��
��, �i��' 'II,°
r
I n s 'Ti:
- k �
Q k�
�,
✓
Q
�i� � � ` ,��+'
�t t��,„.'�`�,r,�r �
�s : �, ,� �;� - � �
f. r_,..r r.t�,.. _
� �
x�� # �
� : �p P
e �f �
� LL '��.
� � �
#�,
,�,r�,
�
� �
�
�t . �
. . *;:.
���� ,� ,,, � .�
�' � , �
,; � � �
,
� . - =.
-
� S�ched 1 - ° - °
u e �.0 �chedu le 40
Fully Listed and FM Approved Sprinkler Pipe
When you specify Schedule-10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product.Although these
products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand.
Our Sch-10 (1'/4"-8")pipe and Sch-40 (1"-2'/Z")pipe have passed the same thorough lab testing as our other listed pipe
products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality.
�
, - . � - . � . - �
Schedule-10/Schedule-40 product can be NPS Nominal I.D. Wt. Wt.(H20 Filled) Pcs/ WULift(21') Wt/Liit(24') WULift(25')
In;mm In;mm Lbs/ft;Kg/m Lbs/Ft,�Kg/m Lift Lbs Kg Lbs;Kg Lbs;Kg
"hot-dip"galvanized to meet FM
reyuirements for dry systems in 1� 1.049 1.680 2.05 70 2,470 2,822 2,940
' accordance with the zinc coating 25 26.6 2.5 3.05 70 1,120 i,280 1,334
specifications of ASTM A-123. 1'�4° 1.380 2.270 2.93 51 2,431 2,778 2,894
32 35.1 4.36 4.36 5i 1,103 1,260 1,313
, � ' � � • � 1Yz' 1.610 2.720 3.61 44 2,513 2,872 2,992
40 40.9 4.0 5.37 44 1,i40 1,303 1,357
Our advanced formula mill coating of- 2^ 2.067 3.650 5.13 30 2,300 2,628 2,738
fers a clean,durable surface.It is also 50 52.5 5.4 7.63 30 1,043 1,192 1,242
paint-ready for custom color applications 2YZ 2,469 5.790 7.86 19 2,310 2,640 2,750
without special preparation. 65 62.7 8.6 1 i.73 19 1,048 1,197 1,247
The internal surface of all black Allied
Tube&Conduit Fire Sprinkler pipe � � _ �
products up to 4.5000" in diameter is
coated with our new Antibacterial For- NPS Nominal I.D. Wl. Wt.(H20 Filled) Pcsl WULift(21') WtlLift(24') Wt(Lifl(25')
mula,"ABF".In scientific laboratory In;mm In;mm Lbs/Ft;Kg/m Lbs/Ft,�Kg/m Lift Lbs;Kg Lbs;Kg Lbs;Kg
test,ABS proved to have superior resis- 1" 1.097 1.400 1.81 91 2,675 3,053 3,185
tance to microbial colonization of pipe 25 27.9 2.1 2.70 91 1,213 1,385 1,445
walls,thereby delaying or possibly pre- 1y4 1.442 1.810 2.52 61 2,319 2,664 2,760
venting the onset of Microbiologically 32 36.6 2.7 3.75 61 i,052 1,208 1,252
Influenced corrosion(IVIIC)when the 1Yz" 1.682 2.080 3.04 61 2,664 3,045 3,172
First Sprinkler System is first installed. 40 92.7 3.1 4.52 61 1,208 i,381 1,439
� � , . - 2" 2.157 2.640 4.22 37 2,051 2,344 2,442
� 50 59.8 3.9 6.28 37 930 1,063 1,108
' Meets"Buy American"requirement 2yZ 2.635 3.530 5.89 30 2,224 2,542 2,648
, and is available through distributors in 65 66.9 5.3 8.77 30 i,009 1,153 1,201
the USA,Canada and Mexico. 3" 3.260 4.330 7.94 19 1,728 1,975 2,057
� - � � � . �
80 82.8 6.4 11.82 19 784 896 933
4" 4.260 5.610 11.78 19 2,238 2,558 2,665
Schedule-10/Schedule-40 pipe are in 90 108.2 8.3 17.53 i9 1,015 1,160 1,209
' compliance with the following: 5" 5.295 7.77 17.33 10 1,632 1,865 1,943
125 134.5 11.56 25.80 10 740 846 881
ASTM A-135,and NFPA 13.Both pipe 6" 6.357 9.290 23.03 10 1,951 2,230 2,322
products have a working pressure rating 150 161.5 13.8 34.27 i0 885 1,012 i,053
of 300 psi maximum and also meet the g" g.249 16.490 40.15 7 2,424 2,770 2,885
stringent requirement for the following 200 209.5 24.5 59.75 7 i,100 1,256 1,309
tests:
' •Welded Outlets �� FM ���
•H drostatic Pressure
Y
• Side Wall Rupture Listed Approved Listed
•Vibration Test
* CO F/owContro/ � ^Illp^I 16100 S. Lathrop• Harvey, IL 60426 Customer Service:
y / `,� �`,J 11350 Norcom Rd. •Philadelphia, PA 19154 (800)882-5543
TUBE&CONDUIT 2525 N. 27 th Ave. • Phoenix,AZ 85009 Fax 708-339-1806
S5 -3
� ' . SW/NG CHECK
� VALVE
"" STANDARD & "SHOTGUN"
���r
"" MODEL RCV
FIRE SPRINKLER CORPORATION GROOVE/GROOVE
DESCRIPTION AND OPERATION 2�� 2 ��� 3�� 4�� & s�� S/ZES
Globe Model RCV Swing Check Valves feature a swing type
clapper designed for use in fire sprinkler or other types of water
piping systems that incorporate grooved connecting pipe ends.
They are effectively used when it is necessary to permit water flow
in one direction only, preventing flow in the reverse direction (non-
return). Because the RCV incorporates a spring-Ioaded clapper
assembly, it may be installed in either the vertical or horizontal
position. Most commonly, it is used with various configurations of
fire department connections for fire sprinkler systems, by-pass
connections,gravity pressure tank and, pump discharge in connec-
tions from publicwatersupplies to automatic sprinklersystems,etc.
As an alternative to using an alarm check valve with a wet
sprinkler system, an RCV Swing Check Valve may be used in a
"Shotgun" arrangement whereby the valve is trimmed in a similar
manner but utilizes an electric water flow switch and alarm bell
instead of a water motor gong for fire notification.
The body of the Globe RCV Swing Check Valve is constructed MODEL RCV
of high tensile strength cast iron having considerable ductility to SWING CHECK VALVE
reduce damage in field handling. It meets the ASTM A126 Class B
rating. The RCV clapper assembly is made of stainless steel and
has an E.P.D.M. rubber facing. The RCV incorporates a special
stainless steel spring assembly which allows its use in the down-
ward flow direction. It effectively provides a leak tight seal against
back pressures greaterthan one (1) psi. PHYs�ca��inneNsioNs
APPROVALS
• cULus Listed ��H-
s pp -A-
FM A rove OPTIONAL FOR RISER O
• NYC - DOB MEA 305-05-E INSTALLATION
,�.
TECHN/CAL DATA •F-
•Water Working Pressure Rating -300 psi (20 7 Bars). �
� Factory tested hydrostatically to 600 psi (41.4 Bars). E O
Equivalent feet of pipe: 2"Valve=7.2 feet, 2 1/2" ��"
�Valve=7.2 feet, 3"Valve=7.2 feet, 4"Valve-9.9 feet,
6"Valve= 16.1 feet. ,��• �-14NPT "�"��—K
�.���
WEIGHT
SIZE A C E F G H I J K L (Ibs.)
no trim
2" I" 4" 3 I/2" 4 I/2" 6 I/2" I/4" I I/2" 2 I/4" 2 I/2" 4 3/4" 4.5
2 I/2" I I/4" 4 I/2" 4" 5" 7" I/4" I I/2" 2 I/2" 2 3/4" 5 I/2" S
3" I I/4" 5" 4 I/2" 6" 7 3/4" I/4" 2" 3" 3 3/4" 6 3/4" 12
4" 2" 6 I/4" 4" 6 I/2" S I/2" I/4" 2 I/2" 3 I/2" 4 I/4" 7 I/2" 17.5
6" 2" 8" 5" S" 10 I/2" I/4" 3 I/4" 4 I/4" 5 I/2" 10" 40.5
4077AIRPARKDRIVE,STANDISH,MICHIGAN 48658 989-846-4583 • FAX989-846-9231
OCTOBER2005 J-10 BULLETIN RCV REV.#1
SW/NG CHECK VALVE -�2", 2 %'; 3�� 4" & 6��
MODEL RCV - STANDARD � '�SHOTGUN"
GROOVE/GROOVE
ITEM DESCRIPTION MATERIAL 2"P/N 2%:"P/N 3"P/N 4"P/N 6"P/N
3
I Hinge Pin Srainless Steel 321521 321528 321535 321541 321549
�\`` � 12 2 Torsion Spring Sainless Steel 321523 321531 321531 321545 321554
Z 3 Machined Body Castlron 321501 321503 321505 321507 321509
g � 10 4 I/2"NPT Plug Cast Iron 311003 311003 311003 311003 311003
5 Seat Ring Brass 321516 321530 321537 321543 321551
1
6 Locknut Sainless Steel 321556 321556 321556 321556 321556
9
p 7 Nameplate Aluminum 321558 321558 321558 321558 321558
5 8 Clapper Stainless Steel 321515 321527 321534 321540 321548
4 9 Clapper Facing Disc EPDM 321516 321529 321536 321542 321550
�� 6 10 Sealing Washer Hard Fiber 321518 321518 321518 321518 321518
CROSS SECTION I I Disc Retainer Sminless Steel 321517 321517 321517 321544 321544
12 Hex Head Bolt Stainless Steel 321519 321519 321555 321555 321559
��SHOTGUN�� TRIM ARRANGEMENT
2 SIZE A B C 4 �
„A„ 7
2" 10" 8 3/4" 2 I/4" 5
3 6
2 I/2" II" 9 I/4" 2 I/4"
1 0 �3" 12" 9 1/2" 2 I/2" 4 �
4" 13 I/2" 10" 3 I/4" 8
� 5
6" 14 I/4" 10 3/4" 4" 6
� „B,. „�.,
TOP VIEW FRONT VIEW
ITEM DESCRIPTION 2" 2%3" 3" 4" 6" QTY.
I RCV 321526 321533 321539 321547 321557 I
2 Angle Valve 311614(I") 311615(I I/4") 311615(I I/4") 311617(2") 311617(2") I
3 Close Nipple 310500(I") 310600(I I/4") 310600(I I/4") 310800(2") 310800(2") I
4 I/4"Water Gauge 300119 300119 300119 300119 300119 2
5 I/4"3 Way Valve 31 1683 31 1683 31 1683 31 1683 31 1683 2
6 I/4"Plug 311001 311001 311001 311001 311001 2
7 I/4"Nipple 31 I 101 (I I/2") 31 I 102(2") 310102(2") 310103(21/2") 310103(2 I/2") I
8 I/4"x 5 I/2"Nipple 310109 310109 310109 310109 310109 I
ORDER/NG INFORMAT/ON GLOBE° PRODUCT WARRANTY
Globe agrees to repair or replace any of its own
SPECIFY manufactured products found to be defective in material
•Quantity • Model Number or workmanship for a period of one year from date of
•Standard or Shotgun style. shipment.
For specific details of our warranty please refer to
Price List Terms and Conditions of Sale(Our Price List).
�� �eii �� �
4077AIRPARKDRIVE,STANDISH,MICHIGAN 48658
FIRE SPRINKLER CORPOEtATION 989-846�583 FAX989-846-9231
OCTOBER2005 PRINTEDU S.A. BULLETINRCVREV.#1
� � � • i
I � c
� � o
� � � � � � �
„� ��
MODEL�O'I1A IVIODEL�O��/�SG DIMENSIONS
I�B�I Orifice Size Available:3/a",'/is",�/z",��/sz", ELO(5/a")
I�e�I f Model A B C D
� ^ o V €lil 3011A 3�/6�� 4»/6�� ���8�� 4��8��
1 � ��� 1 p5 mm) (118 mm) (200 mm) (124 mm)
� 3011ASG 3�/6�� 4»/s" 9�/is" 6�/a"
� � � p6 mm) (1;8 mm) (237 mm) (159 mm)
� — 0 3011BV 3/is 4 /s _ _
D p5 mm) (11 B mm)
� � � 3011SG 3�/is" 4»/s" 6�/is" 3�/a"
m � p5 mm) (178 mm) (157 mm) ps mm)
I�OIODEL 3O���V MODEL�O'I 1 SG RAATER9ALS APPROVALS
I�—s�I Handle:Steel UL and ULC Listed:
} Stem: Rod Brass [EX4019(N)&DC4533(N)]
I~B~ � Ball:C.P. Bronze FM Approved
I � ° �� ��'� Body: Bronze NYC-BSA No.720-87-SM
o Valve Seat:�rgin Teflon�
A ":�_� c t � Relief Valve:Bronze ��
1 ° Bypass Fittings: Brass �,
1 Bypass Tubing:Nylobraid ����
� Sight Glass:Bronze&Glass MADE IH O.S.A.
�ROIVi THE �F�� 13 °�0�7 �DITION
Models 3011 BV,3011SG,3011A,&3011ASG,depending on the variant chosen,provide some or all of the requirements listed below:
Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system.
Chapter 8.16.2.4.2 Drain connections, Interior sectional or floor control valve(s)—shall be provided with a drain connection
&8.16.2.4.3 having a minimum size as shown in Table 8.16.2.4.2.
Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain.
Chapter 8.16.2.4.6 The test connection shall be permitted to be used as main drain connection.
Chapter A.8.17.4.2 (Wet Pipe System)test connection is permitted to terminate into a drain capable of accepting full flow...
using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow
equivalent to one sprinkler...(M3011 SG and M3011ASG only)
Chapter 8.17.4.2.2 The test connection valve shall be readily accessible
Chapter 8.17.4.2.4 shall be permitted to be installed in any location ...downstream of the waterflow alarm.
Chapter 7.1.2 -a gridded wet pipe system shall be provided with a relief valve set to operate at 175 PSI or 10 PSI in excess
of the maximum system pressure,whichever is greater.
Chapter 8.16.1.2.3* A relief valve of not less than�/z" in size shall be provided on the discharge side of the pressure-reducing valve
set to operate at a pressure not exceeding 175 psi.
Chapter A8.16.1.2.3 -consideration should be given to piping the discharge from the(pressure reliefl valve
Chapter 8.17.4.3.1 (Dry Pipe System)a trip test connection not less than 1" in diameter,terminating in a smooth bore corrosion-
resistant orifice,to provide a flow equivalent to one sprinkler...
Chapter 8.17.4.3.2 The trip test connection...with a shutoff valve and plug not less than 1",at least one of which shall be brass.
� . � . .
AGF Manufacturing Inc. Job Name:
100 Quaker Lane,Malvern,PA 19355
Phone:610-240-4900 Architect:
I Fax:610-240-4906 Engineer'
www.testandrain.com
Contractor•
UNITED BR,ASS WORKS, INC.
,�ED � w
�1 714 S. Ma�n-S�t�:, Randleman, NC 27317 �-���Q��•�;�����%
�_� Tel: 800-334-3035 Fax: 800-498-4696 www.ubw.com �S09001
4EGISTEREO COh1PANY
- , n. Mode1126SUL Angle Valve
Soft Disc
cOu
usUL Listed for Fire Sprinkler Service at 250 WOG ,
200 WOG @ 180 ° Max ',
100% Pressure Tested '',
Threaded Ends �
Rising Stem • Inte�ral Seat �
B �
�
_ �, � ,�
I \ �
� I
, O '
� j �
4
C �
� MATERIAL LIST �
� � o
, � , �
� NO. DESCRIPTION MATERIAL �
i , � � �
1 Hex Nut Steel '
2 Hand Wheel Aluminum
�
3 Packing Nut Brass
4 Packing Graphite Non-Asbestos '�/� ' �
5 Bonnet('/z" —1") Brass A " � i %i� '' �
Bonnet 1 '/4"—2" Bronze i �
6 Stem&Seat Assembly Brass i 8
i.
7 Disc Buna N
A
8 Body Bronze
Size 'h" 3/4„ 1„ 1 '/4" 1 %z„ 2„
A 1.03 1.22 1.47 1.75 2.00 2.34
B 2.03 2.38 2.75 3.00 3.72 3.72
C(closed) 3.13 3.25 4.38 4.50 5.25 5.63
Ship Wt.(lbs.) 0.69 0.94 1.76 2.50 3.26 5.32
Qty.Unit Pack 12 6 6 4 2 2
Qty.Per Case 72 60 36 24 12 12
r::�
° GLR300G
■�
�
� ••� GroovedButter a
�b FIRE SPRINKLER ,f lJ� v ZVeS ,
CORPORA7'��N Grooved End,Sizes : ''i
21/2",3",4", 6"and8►► �
Specifications I
Working Pressure 300 PSI (21.4 Bars) I
Ma�c. Test Pressure : 600 PSI (42.8 Bars)
Max. Working Temp : 250°F (120°C)
Factory installed UL Listed Double Tamper
Switch For Indoor and Outdoor Use.
Materials of Primary Components
.
Body: ASTM A-536 Nylon-11 Coated
Disc • ASTM A-536 EPDM
Encapsulated �
Upper and Lower Stems : AISI 420-SS °t
Worm Gear Shaft : AISI 410-SS �` ��
Housing : ASTM A-536 �i
Hand Wheel : ASTM A-536 ���
Flag Indicator : ASTM A-536 ,a*
Sheer Pin : ASTM A-510
Segment Gear : ASTM B-148 or B-584
Housing Gasket : EPDM Grade "E"
O-Rings (All) : EPDM Grade "E"
Approvals
NYC - DOB MEA Approved 155-06-E �
UL, ULC Listed i,
FM Approved I
� - - ►
� I �
- --►
i �
I � o I
� - I -- - - -- --- - � __ _ _ , . _-
- - � -- - --.\`"-, ,_- - --
� �
� I j � �
� � � � � I
, i
'-�-- - -►� - - -�' ' __ ;
, '� ' � � , ►
DIMENSION uNIT:IN(mm)
SIZE A B C D E Part No.
2'/:" 5.31 (135) 5.04(128) 4.13(105) 3.30(85) 3.80(96.4) 311785-G
3" 5.59(142) 5.04(128) 4.41 (112) 3.60(92) 3.80(96.4) 311790-G
4" 6.89(175) 5.04(128) 5.71 (145) 4.30(108) 4.54(115.4) 311795-G
6" 8.23(209) 8.66(220) 7.05(179) 5.71 (145) 5.21 (132.4) 311805-G
B" 9.21 (234) 8.66(220) 8.03(204) 6.70(170) 5.80(147.4) 311815-G
AUGUST2006 Page4 BULLETIN BUTTERFLYREV#2
GROOVED END ' •
Flow Characteristics
1.2
�.Q� G1/" �n !��� Vn pn �
0
o= ��a �_ .� � --'
W W o.s
� ! I �
y� I � i
� ) __�. .� ___�J �
W fA _d �
a W �.6 �
J a ��._ ....�r� i
�z � �_�__ ._� � 9
O
Z O O.4 _, _ �
Z 0.2� � �� _�._ � �_._s r � f
�e.�, �._��
o.o
� j l_. - -- �_J f�r _..� _��1
100 1,000 10,000
FLOW RATE IN GALLONS P92 MINUTE(GPM)
WAFER AND GROOVED END
Friction Loss
Friction Loss in Friction Loss in
Valve Size in. Equiv. Feet of Valve Size in. Equiv. Feet of
Valve Model (mm) Pipe Valve Model (mm) Pipe
DW(Wafer) 2%Z(65) 4.8 DG(Grooved) 2%:(65) 6.9
3(76.2) 3.5 3(76.2) 4.1
4(100) 2.4 4(100) 3
6(150) 5.1 6(150) 5.5
8(200) 5.4 8(200) 5.4
GROOVED END
Flow coefficient : Cv
Disk Open Angle
DN (mm) SIZE(in)
30° 40° 50° 60° 70° 80° 90°
65 2'/2' 12 27.4 53.1 96 138 156 163
80 3" 18.9 39.4 78.9 144 210 243 249
100 4" 30 65.1 129 226 377 488 514
150 6" 84 184 369 634 964 1196 1286
200 8" 165 339 677 1230 2002 2850 3129
WAFER TYPE �
Flow coefficient : Cv at full open
DN (mm) 65 80 100 150 200
Size (in.) 2%Z' 3" 4" 6" 8"
Cv 222 389 1000 1998 4619
Cv= tlow(9Pm) _ Q
pressure loss(psi) �P
AUGUST2006 Page6 BULLETIN BUTTERFLYREV#2
� � SHURJOINT� . � � � ' ' ' � "
vin•m.shurjoint.com •
Approvals Products for Fire Protection Piping Systems
COUPLINGS AND FITTINGS
Listing Pipe Rated Working Pressure Pipe Notes(See Coupling and
Shu'oint Pub.
Product❑Model Approval Size Range Wall ❑ psi Fitting Notes on page
Agency Inches Standard Light 13-14) No.
IPS Carbon Steel Grooved Couplings
#7705 Flexible Caupling 1"-8" 300 300
UL 8"(7705I� 450 450 1,2-1,14,IS
10"-12" 175 175
C-01
1"-8" 300 300
'r� FM 8"(7705I� 450 450 2-2,18,19
10"-12" 250 250
#7707 Flexible Coupling 3/4"-1 1/4"" 500 500
2"-8" 500 450 1,3-1,14,17
�•• UL
f . 10"-16" 300 -
18"-24" 250 - C-02
11/2"-10" 500 500
� 12" 300 300 3-2,18,19
14"-22" 175 175
24" 250 250
#7771 Rigid Coupling 2"-8" 300 300
� 10"-12" 175 175 1,5-1,
14"-20" -- 300
22"-24" -- 250
C-OS
11/2" 500 500
2"-8" 300 500
FM 10" 200 200 5-Z,
12" 300 300
14"-24" 175 175
#Z07 Angle Pad Coupling 1 1/4"-4" 500 500
� 5"-S" 400 400 1,8-1
� 10" 350 350
� 12" - - C-06
1$
� 11/4"�" 500 500
_ i � 5"-8" 400 400 8 2
10" 350 350
12" 350 350
#K9 Lightweight Rigid
Coupling � 1-1/4"-8" 300 300 1,4-I,
8"(K-9E� 350 300
�'" - _ G-Ol
� 1-1/4"-8" 300 300 ¢Z
' 8"(K-9I� 300 300
1/14
SHURJOINT�IS AN ISO 9001 CERTIFIED COMPANY
Shurioint Pioina Products • 1 800 746-GROOVED • Las Veaas.Nevada USA• www.shurioint.com
� � SHURJOINT� . " ' ' ' "
vnav.shury'oint.com •
#ZOS Angle Pad Rigid
Coupling
�---
� 1 1/4"-8" 350 350 1,7-1
f�
G-03
I
I
,� �
FM 11/4"-8" 350 350 7-2
#7706 Reducing Coupling �
� 2"x 1-1/2"� 300 300 1,10-1
�' g��X 6„
C-07
`�
�y � 2"x 1-1/2"� 300 300 10-2
8"x6"
#R20 Rigid Coupling
� 1-1/4"-6" 300 300 1,6-1
G13
FM 1-1/4"-6" 300 300 6-2,
IPS Carbon Steel Grooved Flanges
#7041 Flange-ANSI 125/150
� 2"-8" 175 175 1,9-1
iw���'`!�
� D-01
`��r�%'
c°I� �— , A
�r�- � z�°-za�� i�s i�s 9-2
#7043 Flange-ANSI 300
� 2"-12" 300 300 1
o - D-03
FM 2"-12" 300 300
�o-.
IPS Carbon Steel Hole Cut Products
#7721 Mech.Tee,Threaded
Oudet
� 2"x 1/2"- 300 300 1,13
� 8"x 4"
� �� F-01
�' , --
FM Z��X l�Z� 300 300
4"x8"x4"
#7722 Mech.Tee,Grooved
OuUet 3"x 1 1/2"-
UL 300 300 1,13
� 8"x 4"
:i �,
!� F-02
� � 3"x 1 1/2"- 300 300 -
8"x4"
2/14
SHURJOINT�IS AN ISO 9001 CERTIFIED COMPANY
Shurioint Pioina Products • 1 800 746-GROOVED • Las Veaas.Navada USA• www.shurioint.com
� �SHURJOINT� . " ' • ' ' '
T
v.ti�nv.shurjaint.com .
#C-7T Ouflet Couplings
� 1-1/2"x 1/2"- 300 300 1 •
6"z 1-1/2"
Ip -`'
f �+
G10
\
1
� 1-1/z"x 1/z"-
6"x 1-1/2" 300 300
#C-7G OuUet Couplings
� 2"x 1" 300 300 1,
6"x2"
i
C-]0
_ �
FM Z��X 1�� 300 300 -
6"x2"
#723 Saddle Let
� 1 1/4"x 1/2"- 300 300 1,12-1,
3"x 1"
!� d
F-03
i r 1 1/4"x 1/2"-
r4 � 3"x 1" 300 300 12-2
IPS Carbon Steel Grooved Fittings
#901 Short Radius 90°Elbow
UL 2"-8" 300 300 1,
G-02
FM 2"-8" 300 300 --
#903 Short Radius Tee
' i7i- 2"-8" 300 300 1,
G-02
4
� 2"-8" 300 300 --
#7110 90°Elbow
� 1"_18" 300 300 1
20"—24" 250 250
1"—8" 500 500 E-02
10"—12" 300 300
� 175 --
14"-18",24" 175
20" 250 250
3/14
SHURJOINT�IS AN ISO 9001 CERTIFIED COMPANY
Shurioint Pioina Products • 1 800 746-GROOVED • Las Veaas.Nevada USA• www.shurioint.com
� � SHURJOINT� . ' " ' ' ' � "
v,n�nv.shu�joint.com •
#711145°Elbow
� 1-1/4"-18" 300 300 1'
:�
20",24" 250 250
E-02
1-1/4"=8" 500 500
10"-12: 300 300
FM 175
14"-18",24" 175
20" 250 250
#7110DR Drain Elbow
UL 2"-6" 300 300 1,
G-OS
FM 2"-6" 300 300 --
#7110LR 1.SD Elbows
iA- 2"—8" 300 300 1
E-04 I
FM 2"—S" 300 300 —
#7112 22-1/2°Elbow
� 1-1/4" 500 500 1
1-1/2"-8" 300 300
E-04
FM 2"-8" 300 300 —
#7113 11-1/4°Elbow
UL 2"—S" 300 300 1
E-02
FM 2"—8" 300 300 —
#7120 Tee
� 1-1/4"—18" 300 300 1
20"—24" 250 250
E-OS
1-1/4"—8" 500 500
� 10"—14" 300 300 --
16" 175 175
#7121 Reducing Tee
' � 2"x 1-1/2"—12"x 300 300 1
10"
&06
� 2"x 1-1/2"— 300 300 --
6"x 4"
4/14
SHURJOINT�IS AN ISO 9001 CERTIFIED COMPANY
Shurioint Pioina Products • 1 S00 746-GROOVED • Las Veaas.Nevada USA• www.shuriofnt.com
� � SHUR,JOINT° . ' ' ' ' ' " "
�nn�w.shury'oint.com •
#7151 Eccentric Reducers
� 2 1/2"x 2"- 300 300 1, I
8"x 6"
E-07
FM 2 1�2��X 2�� 300 300 --
8"x 6"
#7160 End Cap
UL 1-1/4"-8" 300 300 1,
E-08
FM 1-1/4"-12" 300 300 --
#7160H End Cap
� 10"-18" 300 300 1
' 20"—24" 250 250
'~ -� E-08
� 10"-12" 300 300 _
14"—24" 175 175
#7160T Transition Fittings
2"x 1"—
UL 300 300 1,
4 6��X 2��
G-08
� 2"x 1"— 300 300 --
6"x 2"
#7170 Flange Adapter
. UL 21/2"-6" 175 175 1
�`�z,�
D-04
;,,���'� FM 2 1/2"-6" 175 175 —
.,_�
#7180 UniversalFlange
Adapters '
iJI, 2"-8" 300 300 --
,
D-08
�
FM 2"-8" 175 175 21
#55 Nipple Adapters
UL 1 1/2"-2" 300 300 1
� G-07
FM 1 1/2"-2" 300 300 --
6/14
SHURJOINT�IS AN ISO 9001 CERTIFIED COMPANY
Shurioint Pioina Products • 1 800 746-GROOVED • Las Veaas.Nevada USA• www.shurioint.com
� � SHUR,JOINT� . ' ' ' ' ' ' "
m�nv.shuryoint.com •
#899 End All Fitting
� 1 1/4"x 1/2"— 300 300 1,
2-1/2"x 1"
G-06
I
FM 1 1/4"x 1/2"— 300 300
2-1/2"x 1"
IPS Carbon Steel Outlet Fittings
#71 Female Threaded Ouflet Outlet x Header
Fitting %s"x 1"-8",
���X 1�/���g��
1,/��X Z��_8��
� 1'/d'x 2"�S" 300 300 1,
2��x 2°_8��
2'/i'x2'/z'�-8��
2'/z(76.1)���,/Z�_8��
3"x 3"-8" H-01
4"x 4"�8"
' �/�� ��4 1��X 1���g��
� 1'/•",1'/z x 2"-8"
FM Z� X Z��'��8�� 300 300 --
2'/a"x3"--8
3��x 4���g��
4"x 5"�8"
#72C Cut Grooved Outlet
Z��X 2��_8��
Fittings 2-1/2"x2-1/2"--8"
� 3"x 3"--8" 300 300 I,
4��x 4��_8��
R 6"x6"x8"
� �
8"x 8"x 10" H-02
� 2-1l2"x3"-8
3��X 4"_8��
FM 4"x 5"�8" 300 300 --
6"x8"
8"x 1�"
#72R Roll Grooved Outlet 1-1/4"x 1-1/2"�S"
Fittings 1-1/2"x 1-1/2"-8"
UL 2��X 2���8" 300 300 1,
2-1/2"x2-1/2"--8
�_ 3��X 3��_g��
4"x 4"--8"
H-03
1-1/4"x 1-1/2"�8"
1-1/2��X Z"�g��
FM 2��x 2-1/2"�8" 300 300 --
2-1/2"x3"--8
3"x 4"�8"
4"x 5"--8"
7/14
SHURJOINT�IS AN ISO 9001 CERTIFIED COMPANY
Shurioint Pioina Products • 1 800 746-GROOVED • Las Veaas.Nevada USA• www.shurioint.com
� � SHURJOINT� . ' ' ' ' ' " "
vhnv.sfiurjoint.com •
#74 Universal Threaded 1/2"x 1''�8"
Outlet Fitting
3/4"x 1"�8."
� 1"x 1-1/4"-1-1/2" 300 300 1,
1"x 2"�2-1/2"
1"x 3"—8"
- H-04
1/2��X 1��_$��
3/4"x 1"�8"
� 1"x 1-1/4"�1-1/2" 300 300 —
1"x 2"�2-1/2"
1"x3"�8"
Ductile Iron Fittings
#811 90°Elbow
iJI. 1/2"-2-1/2" 300 300 1
�
I-Ol I
FM 1/2"-2-1/2" 300 300 __
#812 Reducing 90°Elbow
3/4"x 1/2"—
� 2-1/2"x 2" 300 300 1
�'. I-Ol
3/4"x 1/2"—
FM Z-l�z��X 2" 300 300 — 'I
#813 45°Elbow I
iJL 1/2"—2-1/2" 300 300 1
I-01
FM 1/2"—2-1/2" 300 300 --
#814 S�aight Tee
UL 1/2"-2-1/2" 300 300 1
,
� � I-Ol
5
FM 1/2"—2-1/2" 300 300 --
#815 Reducing Tee
UL 3/4"—2-1/2" 300 300 1
I
I-ol
3/4"x3/4"xl/2"
FM — 300 300 --
2-1/2"x2"�c3/4"
8/14
SHURJOINT�IS AN ISO 9001 CERTIFIED COMPANY
Shurioint Pioina Products • 1 800 746-GROOVED • Las Veaas.Nevada USA• www.shurioint.com
� � SHURJOINT� . ' ' ' ' ' " "
wenv.shurjoint.com •
#816 Reducing Coupling •
3/4"xl/2"—
� 2-1/2"x 2" 300 300 1
I-01
3/4"x 1/2"—
� 2"x 1-1/2" 300 300 --
#817 Cross
UL 1"-2" 300 300 1
�
I-Ol
1/2„_Z„
� 1-1/4"xl"-2"xl" 300 300 —
#818 Straight Coupling
UL 1/2"—2-1/2" 300 300 1 �
I-Ol
I
FM 1/2"-2-1/2" 300 300 --
#819 Plug
iJL 1/2"—2" 300 300 1
I-Ol ;
FM 1/2"—2" 300 300 —
#820 Caps
UL 1/2"—2-1/2" 300 300 1,
r'�_: - -
I-Ol
FM I/2"—2-1/2" 300 300 --
#825 Extension Pieces
1/2"x 1-1/2"—
" � 3/4"x 2" 300 300 1,
I-Ol
I/2"x 1-1/2"L—
FM 300 300 —
3/4"x 2"L
9/14
SHURJOINT�IS AN ISO 9001 CERTIFIED COMPANY
Shurioint Pinina Products • 1 800 746-GROOVED • Las Veaas.Nevada USA• www.shurioint.com
• � SHURJOINT� . ' ' ' ' ' • '
vnw�.shurjoint.com •
Couplings and Fittings Notes
1. MEAAppmved#322-06-E.
2. 2-1)UL Listed at 300 psi on the following sizes&pipe.
1-1/4"--�4"on XL,XL-II pipe,Dyna-Flow,Super-Flo pipe manufacriued byAllied'ILbe&Conduit Corp,1-1/4"�6"on BS1387(Ivn,British
Standard Medium Steel pipe,
1-1/2"-3"on Eddy Flow pipe.,1-1/4"�2"on Eddylite pipe manufachaed by Bull Moose Tube Co,
1-1/4"�2"on Fire-Line Threadable pipe manufactured by Westem International Forest Products Inc.
UI.Listed at 175 psi on the following sizes&pipes.
1-1/2"�3"on Eddy Flow Pipe manufachued by Bull Moose'hibe Co,
1-1/4"�4"on Fire-Line Flow pipe manufactured by Westem Intemational Forest Products Inc.,
1-1/4"�2"&3"on SPS pipe manufactured byYeh Phui Enterprise Co.,Ltd.
1-1/4"—3"on Sch.5 pipe,l0"on Sch.10(0.188 in)pipe,12"on Sch.30(0330 in)pipe.
2-2)FM approved at 300 psi on the following sizes&pipes.
1-1/4"�6"on BS 1387M or heavier grade pipe.
1"�4"on Dyna-Flow,Super-Flow(Allied)pipe
1"�2"&3"on Super 40,Super-XL(Allied)pipe.
1"�3"onXL-II(Allied)pipe
1"�2"on BLT,Dyna Thread(American lhbe),Fire-Thread,Eddylite(Bull Moose),1'L(Central),LS pipe,
1-1/2"�4"on Eddy Flow(Bull Moose'Ihbe)pipe
1-1/4"&1-1/2"on Fire-Flowpipe
FM approved at 175 psi on the following sizes&pipes.
1"�2"on WST(Weatland),Ultra Eddy(Bull Moose)pipe.
3. 3-1)UL Listed on the followfng sizes&pipe.
At 500 psi in 2-1/2",5"-6"on BS 1387(Ivn,British Standard Medium Steel pipe pipe,
At 450 psi in 1-1/2"8c 4"on Dyna-Flow pipe manufactured by Allied Tube&Conduit Coip,
At 300 psi in size 10"&12"on sch.10(0.188 in)pipe,14"&16"on Sch.30(0.375 in)pipe,
At 250 psi in 18"-24"on Sch 20(0375 in)pipe.
3-2)FM approved on the following sizes&pipe
At 500 psi in 2-1/2",5"�6"on BS 1387 medium or heavy grade pipe
4. 4-1)iJL Listed at 300 psi on the following sizes&pipe.
1-1/4"--8",3.00D,6.SOD on BS1387(M),British Standazd Medium Steel pipe pipe,
1-1/4"&2"on Eddylite pipe manufachued by Bull Moose'hibe Co,
1-I/4"—2"on Fine-Line Threadable pipe manufactured by Westem Intemational Forest Products Inc.,
2"on Eddythread 40 pipe manufactured by Bull Moose Tube Co.
UL Listed at 175 psi on the following sizes&pipes.
2"�3"on XL-II,XL pipe manufactured by Allied Tube&Conduit Cocp,
2"�4"on Dyna-Flow,Super-Flo pipe manufactured byAllied'Ihbe&Conduit Corp,
1-1/4"--4"on FLF pipe manufactured by Westem Intemational Forest Products Inc.,
1-1/4",2"-3"on SPS pipe manufactured by Yieh Phui Enterprise Co.,Ltd.,
1-1/4",2"--3"on Sch.5 pipe.
4-2)FM appraved at 300 psi on the following sizea&pipes.
2-1/2",5"-6"on BS 1387(Ivn medium or heavy grade pipe,
' 1-1/4",1-1/2"&4"on Fire-Flow(A1lied)pipe,
1-1/2"&2"an Fire-Thread pipe,
1"�3"on Super40,Super-XL pipe,
1"-2"on TL(Centtal)&LS pipe.
FM approved at 175 psi on the following sizes&pipes.
1-1/4"-3"on XI,-II(Allied) pipe,
1-1/4"�2",3"---4"on BS1387 pipe,
1-1/4"--4"on Eddy-Flow,Super-Flo pipe,
1-1/4"�2"on BLT,Eddylite,WST(Wheatland),Gal-5(IDOD Systems)pipe,
1"-2"on Ultra Eddy(Bull Moose)pipe,
1-1/2"�4"on Eddy-Flow pipe.
5. 5-1)iJI.Listed at 300 psi on the following sizes&pipes.
2"�6"on BS 1387(Ivn,British Standazd Medium 5tee1 pipe pipe,
14"&16"on Sch.30 pipe,
18"&20"on Sch.20 pipe.
UL Listed at250 psi in size 22"&24"on Sch.20 pipe.
5-2)F1VI approved at 175 psi in size 22"&24"on Sch.20 pipe.
6. 6-1)iJL Listed at 300 psi on the following sizes&pipe.
1-1/4"-6"on BS1387 pipe,1-1/4"—3"on Super 40,3uper-XL pipe,1-1/4"—4"on Dyna-Flow,Super-Flo pipe,1-1/4"-1-1/2"on
Fire-Line Flow pipe,1-1/4"�2"on Fire-Thread pipe&Eddlylite pipe.
UL Listed at 175 psi in size 1-1/4"�2"on Sch.5 pipe.
6-2)FM approved at 300 psi on the following sizes&pipes.
1-1/4"�6"on BS1387 pipe,
1-1/4"—3"on Super 40,Super-XL(Allied)pipe,
1"�4"on Dyna-Flow,Super-Flo(Allied)pipe,
1"�2"on Ultra Eddy(Bull Moose)pipe,
13/14
SHURJOINT�IS AN ISO 9001 CERTIFIED COMPANY
Shurioint Pioina Products • 1 800 746-GROOVED • Las Veaas.Nevada USA• www.shurioint.com
� � SHURJOINT� . ' ' ' ' ' ' "
vnawshurjoint.com •
1-1/2"�2"onFire-Threadpipe,
1-1/4"�2"on Eddylite(Bull Moose),WST(Wheatland)pipe.
7. 7-1)i1I.Listed at 350 psi on the following sizes&pipe.
1-1l4"---4"on BS1387(lv�British Standazd Medium Steel pipe pipe
2"�4"on Dyna-Flow,Super-Flo pipe manufactured by Allied'15�be&Conduit Corp,
UL Listed at 300 psi on the following sizes&pipe.
1-1/4"-2"on XL,BLT,WLT pipemanufachued by Allied Tube&Conduit Corp,
1-1/4"�2"on WLS manufactured by Wheatland'ilibe Co
1-1/4"-2"on Eddylite pipe manufactured by Bull Moose Tube Co.
1-1/4"�2"on Fire-Line Threadable pipe manufactured by Western Intetnarional Forest Products Inc.1-1/4"�l-1/2"on Dyna-Flow,
Super-Flo pipe manufactured by Allied'hibe&Conduit Corp,
1-1/4"--4"on Mega-Flow pipe manufactured by Wheatland'hibe Co.
1-1/4"on Eddy Flow pipe manufactuted by Bull Mosose Tlibe Co.
3"8c 4"on EZ-Flow pipe manufactured by Northwest Pipe Co.,
1-1/4"&2"on MT pipe manufactured by Wheatland 11�be Co.
UL Listed at 175 psi on the following sizes&pipes.
1-1/2"�3"on Eddy Flow pipe manufactured by Bull Mosose�be Co.,
1-1/4"-2"on Sch.S pipe,
6"on EZ-Flow pipe manufactured by Northwest Pipe Co.,.
7-2)FM approved at 350 psi in size 1-1/4"on XL pipe.
FM approved at 300 psi on the following sizes&pipes.
2"-4"on Dyna-Flow,Super-Flo pipe,
1-1/4"�-�4"on Mega-Flow pipe.
FM approved at 175 psi on the following sizes&pipes.
2"--4"on Dyna-Flow,Super-Flo pipe,
1-1/4"�-�4"on Mega-Flow pipe.
1-1/2"�3"on Eddy Flow,Fire-Thread pipe.
8. 8-1)iJL listed at 300 psi on the following sizes&pipe.
1-1/4"-4"on Dyna-Flow manufactured by Allied Tube&Conduit Corp.,and EF pipe manufactured by Bull Moose Tube Co.,and
Mega-Flow pipe manufactured by Wheatland Tube Co.
3"�4"on EZ-Flow pipe manufactured by Northwest Pipe co
1-1/4"�2"on Eddylite pipe manufactured by Bull Moose Tube Co.,and MLT,WLS pipe manufactured by Wheatland Tube Co.
UL Listed at 175 psi on the following sizes&pipe.
1-1/4"�4"on Eddy Fiow pipe manufactured by Bull Moose�be Co.
1-1/4"�2"on Sch.5 pipe,
6"on EZ-Flow pipe manufactured by Northwest Pipe Co.
S-2)FM approved at 350 psi in size 1-1/4"2"on XL pipe.
FM approved at 300 psi in size 1-1/4"-4"on Mega-Flow pipe.
FM approved at 175 psi in size 1-1/2'�3"on Fire-Thread,Eddy Flow pipe.
9. 9-1)UL listed at 175 psi on the following pipe.
3"OD,4"-5"on BS1387(Nn British Standard Medium Steel pipe pipe,
12"on Sch.30(0.330 in)pipe..
10"on Sch.10(0.188 in)pipe.
9-2) FM approved at 175 psi on the following pipe.
2-1/2,4 in.British Standard BS 1387 medium or heavy pipe.
2"�12",14",16"24"Min schedule cut groove pipe to be joined:8 in.or smaller Schedule 40.
2"�12",14",16"24"Min schedule rolled groove pipe to be joined:8 in.or smaller Schedule 10.
10. 10-1)UL listed at 300 psi in size 3"z2"-2-1/2",4"g2-1/2"-3",6"g4"on BS1387 and
10-2)FM approved at 300 psi on BS 1387(lvn or heavy gade pipe.
11. UL listed at 175 psi in size 1-1/4"2"on BS1387 pipe.
12. 12-1)UL listed at 300 psi in size 1-1/4'=2-1/2"on XL,Super-Flo pipe,175 psi in size 1-1/4"�2-1/2"on Dyna-Flow,XL-II,BS1387 pipe.
12-2)FM approved at 300 psi in size 1-1/4"2-1/2"on Dyna-Flow,XL,Saper-Flo(Allied)pipe,l-1/4"—Z"on BLT(Allied)pipe,TL
(Central),Eddylite(Bull Moose),R'LS,LS (Wheatland)pipe.
13. 13-1)UL listed at 300 psi in size 2"z 2'/a"^-8"x 4"on BS1387 pipe
13-2)UL listed at 300 psi in size 3"x 1'/a"�8"a 4"on BS1387 pipe
14.Light wall pipe shall be of the minimum wall tlucl�ess 0.188 in.Sch.10.
15.Rolled and Cut grooved basked on Sch.30(0.330")pipe.
16.Rolled and Cut grooved based on Sch.20(0.375 wall thicl�ess pipe)
17.Rolled and Cut grooved based on Sch.30(0375 wall tf►iclmess pipe)
18.Minimum schedule cut groove pipe to be joined:6"in or smaller-Sch.40;8"in or larger—Sch.30
19.Minimum schedule roll grooved pipe to be jained:6"or smaller—Sch.10,8 and 10"-0.188 in wall;12"-0.250 in wall.
20.UL listed at 300 psi in size 76.1mm,139.7mm,165.1mm on Sch.lOS,40S pipe.
21.a)Provides a rigid transition between flanged camponents and a grooved system.
b)Min schedule cut groove pipe to be joined:8 inches or smaller-Sch.40
c)Min schedule rolled groove pipe to be joined:8 inches or smaller—Sch.10.
14/14
SHURJOINT�15 AN ISO 9001 CERTIFIED COMPANY
Shurioint Pioina Products • 1 800 746-GROOVED • Las Veaas.Nevada USA• www.shurioint.com
. �;.,,.4 e."'�.a' `��+- � �
:3:A�DJ�g�4 aS���.yiTA}BLE��;�°St'WIVE�L RING�=HANGERS:, � _
�.��+P4� ',�'�'!F3���:�3"n�'�.�s�Y�n�t�..'41,1', `.'�"�1..-�r� �M'� � _ _
� � �
FUNCTION: Designed for the suspension of non-insulated stationary pipe lines.The
knurled insert nut that allows a verrical adjustment after installation,is Fig. 141 & 141F
tapped to NFPA reduced rod size standards. Fig.141F has a layer of felt NFPA SWIVEL
which separates the pipe from the hanger to reduce vibration and sound.
APPROVALS: Underwriters'Laboratories listed and Factory Mutual approved Fig.141 RING HANGER
3/"to 8"sizes only.Complies with Federal Specification A-A-1192A(Type
10),Manufacturers'StandardizaHon Society SP-69(Type 10)and NFPA F1g. 141 PRE-GALVANIZED
standards for reduced rod sizes.
Flg. 141F PRE-GALVANIZED
ORDERING: Specify pipe size and figure number. WITH FELT LINING
Pipe Rod .
Size Adj. Max.Rec.Wt.Each ;,=;�A
Size A B C D E Load/Ibs. (in Ibs.) -
r�
'�x 3/e 1'/e 1�/is 23/a 3'/�s 300 .10 `�
3/a 3/s 1"/,s 1'/s 2�/z 3�/is 300 .10 7
1 3/e is/8 1 2'/Z 33/is 300 .10 C
1'/a 3/e 115/,s 1'/,s 213/,s 39/,s 300 .11 ,- -' I B
1'/z 3/e 2'/s 1'/,s 3'/a 3�/s 300 .11 ; �`�\ � �
Z 3Ig 2'/,s 1'/e 35/,s 43Ig 300 .14 �� D � ~ ',
2'/z 3/e 23/a 1'/a 3"/is 5 525 .19 i\ E ,'�/
3 3�s � 2'�a 1'/e 33/a 59/,s 525 .23 ;
3'�z 3�e 33�a 13�8 45/,s 65/,s 525 .25 `.
4 3/8 3'/s 1'/z 4'/2 7 650 .30
5 '/z 45/s 15/s 55/e H3I8 1000 .50
�� 6 '�z 55/s 2'/a 6'/z 913/is 1000 .58
8 '/z 613/is 2'/is 7'S/is 12�/a 1000 .90 �� O
I Note: I{ordering Fig 141F felt lined hangers for pipe sizes of 3'/z"or under,order the next
�argest size to allow for the thickness of the felt lining MATERIAL: Low carbon steel
FLJNCTION: Designed for the suspension of non-insulated stationary pipe lines.The Fig. 151 & 151F I
knurled insert nut,allows for vertical adjustrnent after installation.
- Fig.151F has a layer of felt which separates the pipe from the hanger to SWIVEL Ii
reduce vibration and sound.
APPROVALS: Underwriters'Laboratories listed and Factory Mutual approved Fig.151 RING HANGER
2'/Z'to 8"sizes only.Complies with Federal Specification A-A-1192A
(T e 10),and Manufacturers'Standardization Socie SP-69(T e 10). Flg. 151 PRE-GALVANIZED
YP iY YP
ORDERING: Specify pipe size and figure number. Flg. 151F PRE-GALVANIZED
I� WITH FELT LINING
P�Pe S ie Adj. Max.Rec.Wt.Each jv���y
Size A B C D E� Load/Ibs. (in Ibs.) _:
�:-i
{'� � =
2'/2 '/2 23/a 1'/a 3"/�s 5�/a 600 .33 _ r� .
3 '/z 3'/s 1'/e 4 5'/s 600 .35 _ - - � �
3'/z '/z 35I8 1'/z 45/,s 65�8 600 .37 �__ �
s > > ,s , .
4 /e 3/s 1 /a 4 /,s 7/a 1000 48 f r' � �
5 5/s 43/8 13/e 55/a 8'/z 1000 .57 f '--�
6 3/a 55�ts 2 6"�ts 10'/8 1250 1.06 ;r � � � ~ ��
I� g a�4 g,s�,s 25�s $S�,s 12'/8 1250 1.32 ; � ,f'f+ y
il � t �{
i Note: 1f ordering Fig 151F elt lined hangers or pipe sizes of 3'/z"or under,order the next y��j
largest size to allow�r the thickness o�he felt lining. y '.��;,� I �
�'
- f.
�
�� F.,..� O
MATERiAL: Low carbon steel
PHD Manufacturing, Inc. •44018 Columbiana-Waterford Road• Columbiana, OH 44408
Toll Free(800)321-2736•Phone: (330)482-9256•Fa�c: (330)482-2763•www.phd-mfg.com
, l✓-.
MALLEABLE IRON BEAM CLAMPS }. ' ��-
� �
Flg. 350 FiJNCTION: Designed for attaching hanger rod to the top flange of a beam or
BEAM CLAMP bar joist,where the flange thickness does not exceed 3/4 inch.The
open U design permits rod adjustment.The universal design of
the 3/8 Fig.350 allows it to be used in an inverted position on the
bottom flange of a beam as well.
APPROVALS: Underwriters'Laboratories listed.Factory Mutual approved 3/e'
and'/Z'sizes only. Complies with Federal Specification A-A-1192A
p� (Type 19)arid Manufacturers'Standardization Society SP-69(Type
f 19).When used in an inverted position on the bottom of a beam
� flange the 3/s Fig.350 also complies with Federal Specification A-A-
1192A(Type 23)and Manufacturers'Standardization Society SP-69
C (Type 23)
/ MATERIAL: Ductile iron with hardened steel cup point set screw
3 3f.° 1 FINISH: Plain or electro-galvanized
i4 � ORDERING: Specify rod size,finish and figure number.
�i�A
�=3 Rod Max.
` Size Pipe Max. Rec. Wt. Each
Ee I A B C D E Size Load/Ibs. (in Ibs.)
'� f 03/e 1 1'/z 15Ig '/2 4 400 .33
/B
, '/z 1 1'/z 1"�,s '/z 8 500 .34
5/e 1'/is 1'/z 1�/a 5/a 8 600 .39
OF�..„�m 3/4 15�16 13�4 23�8 5�8 8 8�� .6.�
'/e is/,s 13/a 23�8 5/ 8 1200 .60
8
Note: See MSS SP-69 specs for proper set screw torque values.
0 Reversible design approved for bottom beam use.
I
� PHD Manufacturing, Inc. •44018 Columbiana-Waterford Road• Columbiana, OH 44408
Toll Free(800)321-2736•Phone: (330)482-9256•Fa�c: (330)482-2763•www.phd-mfg.com
;.�, .. . .__ ---- -
'- �<-
� � � p � �.�./ �
�
ARGCO __ __ �°�"�'�E°
FIRE ALARM BELLS
• Four wire, 120 and 24 volt �� 10 DIA.GONG /�� ��� �'�^ �
• Indoor and outdoor installation %� ��—�� �� � �,__�
•Weatherproof backbox � � � �� �
I 20 VAC: 6", 8", I 0" � // \\ \� �� � 5��
��
8"DIA.GONG � �� 4„
24 VAC: 6", I0" � I �
\ / �� 3��
\ �� O � /
. 6"DIA.GONG\ � //�/
�„
� "�� � ,�
`#`� 4-3/8" �
�`�� Base
3-29/32"
3-11/32"
3-15/32"
RATING 60 GONG SIZE S�GONG SIZE 100 GONG SIZE ° e �
Rated Sound Level Rated Sound Level Rated Sound Level
VOLTAGE Current at 1 Meter Current at 1 Meter Current at 1 Meter
O Q O
6VDC 250mA 95dB 250mA 95dB 250mA 95dB
12VDC 180mA 95dB 180mA 95dB 180mA 96dB o o Back Box
24VDC 100mA 95dB 100mA 95dB 100mA 96dB
120VAC 25mA 95dB 25mA 95dB 25mA 98dB
220VAC 20mA 95db 20mA 95db 20mA 97db
WIRING INSTRUCTIONS
D.C. BELLS (observe polarity) A.C. BELLS
RED(IN) RED(OUT) RED IN) RED OUT)
O �
from control panel or to next bell or from control panel or
preceding bell end-o%line resistor preceding bell
BLACK IN � � BLACK(OU� BLACK IN � � BLACK OUT)
When electrical supervisor is required use in and out leads as shown. When electrical supervisor is required use in and out leads as shown.
1. Observe polarity to ring DC bells 1. When using AC bells,terminate each extra wire separately
2. Red wires positive(+) after last beil
3. Black wires negative(-) 2. End-of-line resistor is not required on AC bells.
INSTALLATION:
I.The bell should be mounted a minimum of 8 ft.from the floor or as close to the ceiling as possible.
2. Remove the gong
3. Connect the wiring(see diagram).
4. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down).
5. Reinstall the gong(be sure that the gong positioning pin, in the mechanism housing, is in th hole in the gong).
6.Test all bells for proper operation that they can be heard where required (bells must be heard in all areas as designated by the
authority having jurisdiction).
900-854-'1015 www.argco.com FAX 760-727-3270
Waterflow Detector Specifications
Vane-type waterflow detedors shall be installed on system piping as designated on the drawing and/or as specified herein.Detectors shall mount on any
clear pipe span of the appropriate nominal size,either a vertical upflow or horizontal run,at least 6"from any fittings which may change water direction,
flow rate,or pipe diameter or no closer than 24"from a valve or drain.Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a
static pressure rating of 450 psi*for 2"—8"pipes.The detector shall respond to waterFlow in the specified direction after a preset time delay which is field
adjustable.The delay mechanism shall be a sealed mechanical pneumatic unit with visual indication of actuation.The actuation mechanism shall include
a polyethylene vane inserted through a hole in the pipe and connected by a mechanical linkage to the delay mechanism.Outputs shall consist of dual
SPDT switches(Form C contacts).Two conduit entrances for standard fittings of commonly used electrical conduit shall be provided on the detectors.
A grounding provision is provided.Unless noted,enclosures shall"be NEMA 4 listed by Underwriters Laboratories Inc.All detectors shall be listed by
Underwriters Laboratories Inc.for indoor or outdoor use.
Static Pressure Rating 450 PSI* OperetingTempereture Range 32°F to 120°F(0°C to 49°C) i
Maximum Surge 18 Feet Per Second(FPS) Enclosure Rating* NEMA 4—suitable for indoodoutdoor use �
Triggering Threshold 4-10 GPM CoverTamper Switch Standard with ULC models,optional for UL
Bandwidth(Flow Rate) � models,part no.546-7000
Conduit Entrances Two openings for'/�"conduit. Service Use Automatic Sprinkler•NFPA-13
One open,one knock-out type One orTwo Family Dwelling:NFPA 13D
Residential Occupancies up to 4 Stories:NFPA 13R
National Fire Alarm Code:NFPA-72
Contact Ratings Two sets of SPDT(Form C) U.S.Patent Numbers 3,845,259
10.0 A,'k HP @ 125/250 VAC 4,782,333
2.5 A@ 6/12/24 VDC 5,213,205
Compatible Pipe Steel water pipe,schedule 10 through 40 Warranty 3 Years
WFDE Field Wiring Diagram Delay Adjustment Dial Overall Dimensions,Installed
0 0 ,V 1l5'
ow cM�.�,�,�
D�� �— Cam�iimnutlBcanrtliwu � ��Vneni ���v_�--�tyy, �
�� M'JWseMienvarnh COMACTMTINtiS E131 p F
—� do11ec1od,Le.,Nqnv¢tob 12Yt50VAG IOAl1VS /� '
opptlwUmalo��m�dna�0 �<V�C 25AMP5 y/� �
IIqlsEclectcrm ( I��� � 9.0' WFU20 6.6' WF040 88'
0 0 1 �o WFDIS l6' WF�50 ].B'
\ � � WFD3LL2 52 WFD60 9.0'
____wvo wrn � ,`�' � wcoas sr wsoeo toa•
---- – � L
. o . �5
T°�yq°°'° �sa-�'° �—/ u nou Nn �
olgtadFRCP � I --- Cou 1e5��� 1.fi'
-----�---� Plpa mEEie
ryqr�imv com.n�on NOTE ReteN tlme may eaceetl 90 seconds.
aCjust antl venty thaz time Eaes not eaceetl so semntls.
I I w�
To povar I Pl�etic vuio I
wMhCal �� I� �oBkMmaae� MeupBMslan I
olcaxaUon.00 NOTeOvw
cVIppeErNB 19aN�o atertlEe�aM
Trylullnrsl9YlComecWn aMtNlwsln9.DONOTImC�'va.s U�dl ,
WF➢
�itc��a�eniCly
WI�:SMTDIe
�
UL Model ULC Model Pipe Size Hole Size Shipping Weight
WFD20 WFD20A 2" 1'/a" 4.21bs.
WFD25 WFD25A 2'k" 1'/a" 431bs.
WFD30-2 WFD30-2A 3" 2" 4S Ibs.
WFD35 WFD35A 3Y�" 1'/a" 4.71bs.
WFD40 WFD40A 4" 2" 5.21bs.
WFD50 WFD50A 5" 2" 631bs.
WFD60" WFD60A 6" 2" 6.81bs.
WFDSO` WFD80A 8" 2` 7.51bs.
Accessories
A3008-0o Retard mechanism
A77-01-02 Terminal block
546-7000 Tamper proof switch kit
WFDW Tamper proof wrench for cover
WFDN4 Gasketkit
*Maximum pressure rating 400 psi as approved by Factory Mutual.
� S�YSTEM 020075ystemSensor.
�`` +���0� 3825 Ohio Avenue•St.Charles,��60174 Produaspec�cadonssub�ectrorhangewrthoucnoncevwtsystemsensorcomtor
� airterttprodua IMormatlon,induding Me latestversion ofthis data sheet
Phone:800-SENSOR2•Fax:630-377-6495
j�� AUS-0186011•3/07•A1676
rw�,oe,w�
s�Mac�ER
� Contractor's Material and Test Certificate for Under round Pi in �"��ON�°"�
� g P g
A.Procedure Upon completion of work,inspection and tests shall be made by the contractor's representative and witnessed by an
owner's representative.All defects shall be corrected and system left in service before contractor's personnel finally leave the job.A
certificate shall be filled out and signed by both representatives.Copies shall be prepared for approving authorities,owners,and
contractor.It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty
material,poor workmanship,or failwe to comply with approving authority's requirements or local ordinances.All"No"answers
shall be explained in the Comments portion of this forcn.
G. Flushing Tests
Property Name: ��bos- �PxcxY�ct- Taa ls 1.New underground pipuig flushed according
Property Address: S�}'3� (�' r ra 11 't�\o�
to �`� a� standard? �Yes ❑No
Date: a.Flushing conducted by(company): �x�e-¢1Cvs,,1 �-'��G
B.Plans b.Flushing flow obtained from:
1 Accepted by approving authorities(names): ��blic water ❑Tank or reservoir ��e pump
c.Type of opening: ❑Hydrant butt C(Open pipe
Ci�r o� �„�h��•=-h�}� 3.Lead-ins flushed according to
���C'n 62� standard? ❑Yes ❑No
2.Address:
3 Installation conforms to accepted plans �'es ❑No a.Lead-ins flushed by(company): 3e�GCa.� `��Ce'
4 Equipment used is approved C✓1 Yes ❑No b.How flushing flow for lead-ins was obtauied:
C. Instructions ❑Public water ❑Tank or reservoir ❑Fire pump
1.Has person in charge of fire equipment been c.Type of opening: ❑}'.connection to flange&spigot
instructed as to location of control valves and / C�Open pipe
care and maintenance of this new equipment C�Yes ❑No K Hydrostatic Test
2.Have copies of appropriate instructions andf�'e 1.All new underground piping hydrostatically tested at
and maintenance charts been left on premises�Yes ❑No 'Z�l7 psi for 2 hours
D. Location 2.All joints covered? r9'Yes ❑No ,
System supplies buildings: L Leakage Test
E.Underground Pipes and Joints 1 Total amount of leakage measured gal hours
l.Pipe types and class: G�'(DD '�R-1L1 ��VC�
2.Allowable leakage gal hours
2. Jomt type(s): YYl S J.Hydrants
/ 1.Number installed� ,type and make�
3 Pipe confonns to1��F�� bt�l standard�Yes ❑No 2.All operate satisfa orily? {�Yes ❑No
� K Control Valves �
4.Fittings confonn to���� a�( standard0 Yes O No 1.Water control valves left wide open? C�Yes ❑No
5 Jomts needing anchorage clamped,strapped or 2.Hose threads of fire departrnent connections
� � and hydrants interchangeable with those of /
blocked in accordance with�as�andard Cb Yes ❑No fire department answering alann7 �Yes ❑No
F.Test Description L Commetets(I'his section is for additiona!explanation and
Flushing: Flow the required rate until water is clear as notes. A!! "No"answers n:ust be explained{rere.)`
indicated by no collection of foreign material in bwlap bags at
outlets such as h drants and blow-of�s. Flush at flows not less
Y
than 390 gpm for 4-inch pipe,880 gpm for 6-inch pipe, 1560
gpm for 8-inch p�pe,2440 gpm for 10 inch pipe,and 3520 gpm �
for 12-inch pipe.When supply cannot produce stipulated flow �
rates,obtain maximum available.
Hydrostatic: Hycirostatic tests shall be made at not less �
than 200 psi for two hours or 50 psi above static pressure in `
excess of 150 psi for two hours. `
Leakage. New pipe laid with rubber gasketed joints shall,if the
workmanship is satisfactory,have l�ttle or no leakage at
the jomts. The amount of leakage at the joints shall not
exceed 2 qts per hr per 100 joints irrespective of pipe Date left in serv�ce:
diameter.The leakage shall be distributed over all joints.If ❑Check here if comments continue on other side of this forn►
such leakage occurs at a few joints the mstallation shall be M. Signatures
considered unsatisfactory and necessary repairs made. The 1.Name of Installmg Contractor:��ez� �ir� ���.:1-ipr
amount of allowable leakage specified above can be 2.Tests witnessed by
increased by 1 t]oz per inch valve diameter per hr for each Property Owner(signed):
metal seated valve isolatmg the test section.If dry barrel Title: Date:
hydrants are tested with the main valve open,so the hydrants
are under pressure,an additional 5 oz per minute leakage is I�istalling Contractor(signed):
pecmitted for each hydrant. Title: Date:
02007 National Fire Sprinkler Association,40 Jon Barrett Road Patterson,NY 12563(845)878-4200 Fonn 13-U Page 1 of 1
NATIONAL
Contr - tors Material and Test Certificate for boveground Piping F��
���
'A.Procedure Upon completion of work,inspection and tests shall be made by th�contractor's representative and 'O'��1ON'�"`
witnessed by an owner's representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job.A
certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities,owners and contractor. It is
understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material,poor workmanship,or failure
to comply with approving authority's requirements or local ordinances.All "No"answers shall be explained in the Comments portion of this form.
Property Name: F�.a"bo� �a��Wc �b Address: SA3� �(Q-11 �$\ Date:
� O.Tests
B.Plans 1 All piping hydrostatically tested at z0� psi for z hours
1.Accepted by Approving Authorities(Names):(�',a,��„�n���� 2. Dry piping pneumatically tested C�Yes ❑No
2.Address: � 3.Equipment operates properly r�Yes ❑No
3.Installation conforms to accepted plans r,l1'es ❑No 4.Do you certify as the sprinkler contractor that additives and
4 EGuipment used is approved r�Yes ❑No corrosive chemicals,sodium silicate or derivatives of sodium
C.Instructions silicate,brine,or other corrosive chemicals were not used for
1.Has person in charge of fire equipment been testing systems or stopping leaks? �Yes ❑No
instructed as to location of control valves and �
care and maintenance of this new equipment uYes ❑No 5.Drain Test:
a.Static pressure reading of gage
2.Have copies of the following been left on the premises: located near water supply connection � psi.
a.System components instructions u�Yes ❑No b.Residual pressure with
b.Care and maintenance instructions [�es ❑No valve in test connection open wide ss psi.
c.NFPA 25 [�Yes ❑No 6.Underground mains and lead in connections to
D.Location of system-Supplies building(s): risers flushed before connection made to sprinkler
E.S rinklers piping and verified by copy of form No. 13-U �Yes ❑No
Make Model Year Made Orifice Quantity Temperature 7,Flushed by installer of underground piping O Yes ❑No
8.If powder driven fasteners are used in concrete,
� has representative sample testing been satisfactorily /
�L S(9�S Zb�z �1. �2a 2�a dYes ❑No
completed?
P.Blank Testing Gaskets
1 Number used:
2.Locations:
3.Number removed:
Q.Welded Piping-If welded piping was used in the system,
F.Pipe and Fittings complete the following:
1.Type of Pipe: `S3�V- SC�4 y� 1.As the sprinkler contractor,were welding procedures in
2.Type of Fittings: �c� W lrl. -M�� compliance with the requirements of at least AWS B2.
G.Alarm Valve or Flow Indicator ASME Section IX or other required standards Yes ❑No
2.Was welding performed by welders qualified in
(�� compliance with the requirements of at least AWS B2J,
� \�L
ASME Section IX or other required standards I�Yes ❑No
H.Dry-Pipe Valve 3.Do you certify that welding was carried out in compliance
Make,Model and Serial Number: with a documented quality control procedure to insure that
all discs are retrieved,openings in pipe are smooth,slag and
I.Quick Opening Device(Q.O.D.) other welding residue are removed,the intemal diameters of
Make,Model and Serial Number: piping are not penetrated,completed welds are free from cracks,
J.Dry-Pipe System Operating Test Without Q.O.D. incomplete fusion,surface porosity greater than 1/16 inch in
1.Time to trip through test connection*: diameter,undercut deeper than the lesser of 25%of the wall
2.Water pressure psi. Air pressure psi. thickness or 1/32 inch,and the completed circumferen�al
3.Trip point air pressure psi.
4.Time water reached test outlet*: butt weld reinforcement does not exceed 3/32 inch?�Yes ❑No
5.Alann operated properly ❑Yes ❑No R.Cutouts(Disks)
K.Dry-Pipe System Operating Test With Q.O.D.
Do you certify that you have a control feature to
1.Time to trip through test connection*: ensure that all cutouts(disks)are retrieved? �Yes ❑No
2.Water pressure psi. Air pressure psi. S.Hydraulic Data Nameplate Provided C�Yes ❑No
3.Trip point air pressure psi. T.Date left in service(with all control valves open):
4.Time water reached test outlet*: U.Signatures
5.Alarm operated properly ❑Yes ❑No 1 Name of sprinkler contractor:���^Q\ ��� �o��`�?'�
L.Deluge and Preaction Valves 2.Tests witnessed by
1.Make&Model: For property owner(Signed):
Title: Date:
2.Operation: ❑Pneumatic ❑Electric ❑Hydraulic For sprinkler contractor(Signed):
3.Piping and detecting media supervised ❑Y.es ❑No Title: Date:
4.Does valve operate from manual trip and/or V.Comments(This section is for additional explanation and notes. All
remote control stations ❑Yes ❑No "No"answers must be explained here.)
5.Is there an accessible facility in each
circuit for testing OYes ❑No
6.Does each circuit operate supervision loss alarm OYes ❑No
7.Does each circuit operate valve release ❑Yes ❑No
8.Maximum time to operate release:
M.Pressure Reducing Valve
1.Location and Floor: 1
2.Make and Model:
3.Setting: Static Pressure: Inlet _psi, Outlet _�si
4.Residual Pressure(Flowing):Inlet psi, Outlet psi
5 Flow Rate: gpm
N.Test Description
j�Hydrostatic: Hydrostatic tests shall be made at not less than 200 psi for
two hours or 50 psi above static pressure in excess of 150 psi for two
hours. Differential dry-pipe valve clappers shall be left open during test
to prevent damage.All aboveground piping leakage shall be stopped.
Pneumatic: Establish 40 psi air pressure and measure drop. Test
pressure tanks at normal water level and air pressure and measure air
pressure drop. In both cases,the pressure drop shall not exceed 1'/�psi
in 24 hrs.
*Measured from the time the inspector's test connection is opened ❑Check here if comments continue on the reverse side of this form
02007 National Fire Sprinkler Association,40 Jon Barrett Road Patterson,NY 12563(845)878-4200 Form 13-A,Page 1 of 1
��PHYRHlLLS FIRE �EPA�TiVI�i�T
6907 Dairy Road, Z�phyrhills, FL 33542
FIRE SERVICE 11SER FEES
Occupancy Alo.: " �
Plan No.: Contractor:��v�:/-.�../�. -Y„e4✓ `��� �
Business Name: �*{ � v� Bil�Address: � .�.�-�p o �,
Business Address: /��S,�o�.c+s�ss/a � ?3�9�- �
Business Phone No.: Billing Phone No.: ��� ���, . ��� �
Business Fax No.:
Billing Fax No.:
Contact: Contact:
PLAfV REVIEW FEES IIdSPECTIOtd FEES PERMIT FEE FALSE ALARAA FEE
8 Site Plan N/C Annual N7C Sprinkler $50 1st Alarm N/C
MuRi-Family/Commercial .O6 si 1st Re-inspection td/C� � Standpipes $50 2nd Alarm N/C
(Minimum Charge$25.00 2nd Re-inspection $100 Fire Pump $50 3rd Alarm N/C
� Plan Revisions DBL 3rd Re-inspection $250 Hoods $50 4th Alarm $100
4th Re-Inspection $500 Fire Alarm $50 5th Alarm $'150
SPRINKLER SYSTEMS (Business closed untiJ LP Gas $50 6th Alarm $200
0-25 Heads $50 violaGons corrected) Natural Gas $50 NON COMPLUWCE $150
26 plus Heads $100 SPRINKLER SYSTEMS Fuel Tanks- �er�ank $50
STANDPIPE SYSTEM Hydro Undergrounds $45 Sparklers $100
�Per Riser $50 Hydrostatic Test $65 per system Fire Works $500
FIRE PU(�fIP Acceptance Test $45 per system Camp Fire $25
�Per Pump $100 Hydrant Flow $75 ConUolled Bum $700
FIRE ALARM SYSTEN9 Hood/Duct $50
0-25 Devices $50 FIRE ALARM SYSTEAI� Place of Assembly $50 annuai
26 plus Devices $100 System Acceptance $50 Fire Protection $25
SUPPRESSION SYSTEAAS Recall Acceptance $50 Flammable ApplicaUon $50 nnnuai
Wet $50 OTHER Waste Tire Storage $50 rmr,uai
i Dry $50 Fire WalUSmoke Wall $15 Per wan Generator<KW $100
CO2 $50 LP Gas $25 per tank Generator>30 KW 150
Other $50 Natural Gas $25 persyslem BiaHazard Waste $100 nnnuai
KITCHEN EXIiAUST Fumigation Tenting $50
�Hood/Ducts $50 Tent 10k10'or greater $15 perten� Torch PoUApptied $50
OTHER Fire Pump $45 Haz.Materials $100 nnnuai
LP InstallaUon per tank $50 Fire Suppression $30
Fuel Tank Installation $50 System Acceptance
(Per Tank) $50 Exhaust Hood/Duct $30
�Natural Gas InstallaUon $50 e Re-inspeCtion DBL
(Per System) (other than annual)
�Spray Booth $50 �Inspection scheduled DBL
and cance�led less than 8
24 hours
Construction Insp. N/C
Emergency Vehicle A� $50 FkLSE ALARIV
PLANS TOTAL P�d IN�PECTIOPI TOTAL� PERAAIT TOTAL .�o TOTAL�
GRAND TOTAL �-
Comments:
Date: � r� �� �
Inspector: ��,��--:� �-----
nin •
1
��5�j 0
o l5"`�' �-,� •
s �'V .�n i u�:. �
. �i. �
�
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner: �' `������ ��--�'�`�+'.�►`j�il--�,
Date Received: l � � ���
Site: �� � �Q�C, �l 1�U,V
Permit Type: S(�ri`✓� l�-�
Approved w/no comments:� Approved w/the below comments: ❑ Denied w/the below comments: ❑
This comment sheet shall be kept with the permit and/or plans. ,
- � •�o•i7
_ c o
Gene Brown-Fire Safety Officer Date Contractor and/or Homeowner
(Required when comments are present)