HomeMy WebLinkAbout17-18697 ;; CITY OF ZEPHYRHILLS
: 5335-8TH STREET
� � ., �:-
. �sis��so-oo20 186��''
f � BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
�
., �-PERMIT INFORMATION ' LOCATION INFORMATION -
Permit#:18697 Issued: 7/28/2017 Address: 36041 STABLE WILK AVE
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class �f Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 301,317.88 Total Fees: 11,552.19 Subdivision: SILVERADO
Amount Paid: 11,552.19 Date Paid: 7/28/2017 Parcel Number: 04-26-21-0070-00100-0330
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 15550 LIGHTWAVE DR Address: 4600 W. CYPRESS ST STE 200
CLEARWATER, FL. 33760 TAMPA, FL 33607
Phone: (727)479-1740 Lic: Phone: 813-574-5700
Work Desc: CONSTRUCT SINGLE FAMILY 2,833 SQ FT
� APPLICATION.FEES
BUILDIN FEE 1,195.88 ELECTRICAL FEE 246.15 PLUMBING FEE 164.10
MECHANICAL FEE 114.87 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00
SCHOOL IMPACT FEE-sfd 1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
V �
�� � �C
p�Q�- ' ' ��-�,,_^ _ a3 f �
t�l:vti �'��l/'CX> - �
Ins ectio s Re uired
FOOTER 2ND ROUGH PLUMB MIS I SULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
� ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
l DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
frst reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
� NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
' may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
�
CONTRACTORS S GNATURE PERMIT OFFI
PERMIT XPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
C LL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
i�
� 813-780-0020 A�; City of Zephyrhills Permit Application Fax-813-780-0021
' , Building Department
I
Date Received ' �� Phone Contact for Permittin 813 363 __ 2891
Trrrrr'r-r
Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700
Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607
Owner Phone Number
Fee Simple Titleholder Name N�A Owner Phone Number
Fee Simple Titleholder Address N/A
JOB ADDRESS 36041 Stable Wilk Avenue LOT# 0330
SUBDIVISION Silverado Ranch Subdivision Ph 2,3,&4 pARCEL ID# 04-26-21-0070-00100-0330
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED � NEW CONSTR e ADD/ALT � SIGN � � DEMOLISH
INSTALL REPAIR
PROPOSED USE � SFR � COMM � OTHER
TYPE OF CONSTRUCTION � BLOCK � FRAME � STEEL �
DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence -
BUILDING SIZE U/R SF 2854 SQ FOOTAGE 2389 HEIGHT 2 StOf�/
9TTTr TT�TP T�TITTTrP'ITTI"ITI'�TTI'9'7�P
�BUILDING $ � VALUATION OF TOTAL CONSTRUCTION
�� o u
I�/ 'ELECTRICAL $ � PROGRESSENERGY � W.R.E.0
' � ` AMP SERVICE
�PLUMBING $
���/ �MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
, . �
�GAS � ROOFING Q SPECIALTY � OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA �YES �JO
u
-�a-F-E-F-�--�-�+�:-:-:-r��-+��-E-�-+--�-4-�--E-�+�+��+��--��-�--�--�-�+r--��E-r--�-E-�-�F-E-4-+-�-�--�-�-�+F-�--�-�-
BUILDER COMPANY Lennar Homes,LLC
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 4600 W.Cyp ess St.Ste.200,Tampa,FL 33607 License# CGC1518166
ELECTRICIAN COMPANY Edmonson Electric, Inc.
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 1034 Skipper oad,Tampa, FL 33613 �icense# EC13005408
PLUMBER �� COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address P.O. Box 5308, yonet, FL 34674-5308 �icense# CFC042998
MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGNATURE ^� REGISTERED Y! N FEE CURREN Y/N
,4ddress P.O Box 5308, B yonet, FL 34674-5308 License# CAC058062
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 4211 Shoal Line Blv , Spring Hill, FL 34607 �icense# CCC057991
� tt � � � � i � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � i � � � � � � � � � t � � � � � � � � � �
RESIDENTIAL Attach(2)Plot Plans,(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
'**'PROPERTY SURVEY required for all NEW construction.
..��6.-�1-��1..1..4.1..L-1..{—�1..4�1--�.i..�4.1..1..1�f..h1..1..4.L..1��1..1�1..4�1..f..{�I..L��..��1—i..{-1..1..4�1..4..�..{.a�l..��{..�{..{���
Directions:
Fill out application completely
Owner 8�Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
"" Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(PIoUSurvey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
. _� ;r�.�•_•. '
a
x ,
NOTICE OF DEED RESTRICTIOIVS The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance�ith any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTQR RESPONSIBILITIES• If the owner has hired a contractor ar
contractors to undertake work, they may be required to be lice��sed in accarcfance with state and locai regulations. If the .
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact tha Pasco County Building Inspection Divisian—l.icensing Section af 727-847-
8009. Furthermore, if the owner has hired a contractor ar contractors, he is advised to have the contractor(s) sign
portions of the "contractor Black'" of this application for which they wiEl be responsible. If you, as the owner sEgn as the
cantractor, that may be an indication that he is not properly licensed and is not entit(ed to permitting privileges in Pasco
County
TE4ANSPORTATIOIV tMFACTtl77l�(T[ES IMPACT ARID RESCIURCE RECOVERY FEES� The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change af
use in existing buildings, or expansion o#existing buiEdings, as speeified in Pasca County Ordinance number 89-Q7 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, wi�� be identified at the time of
permitting It is further understood that Transpartation Impact Fees and Resource Recovery Fees mus# be paid prior to
receiving a °certificafe of occupancy" or final power release [f the praject does nat inva[ve a certificate af occupancy or
final power release, the fees must be paid priar to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicabie Pasca County ordinances.
CONSTRllCTION LIEN LAW(Chapter 713, Ftorida Statutes, as amended}• if valuation of work is$2,500.00 ar more, 1
certify that I, the applicant, have been provided with a copy of the "Florida Constructian Lien Law—Homeowner's
Protection Guic4e" prepared by the Florida L}epartmenf of Agriculture and Cansumer Affairs If the app[icant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner"prior to commencement.
CONTRACTC►R'S/CiWNER'S AFFIDAViT I certify that ail the informatian in this appNcation is accurafe and that all work
will be done in compliance with all applicable laws regulating constructian, zoning and land development. Application is
hereby made to obtain a permit to do worK and installation as indicated. 1 certify that no vuork or instaEla#ion has
cammenced prior ta issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land devefopment regulations in the jurisdiction. i also
cerfify that I understand that the regulatians of other government agencies may app(y to the intended work, and that it is
my responsibility to identify what actions I mus#take to be in compliance. Such agencies include but are nat limi#ed to:
- Department of Environmental Protectian-Cypress Bayheads, V1letland Areas and Environmerttally �ensifive
Lands,Water/Wastewater Treatment.
- Southwest Flarida Water Management District-Wefls, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navig�ble Waterways.
- C}epartment of Health & Rehabilitative Services/Environmenta! Nealth Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Enviranmental Pratection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill
- Use af fi!! is nat allowed in Flood Zone"V"unless expressly permit#ed.
- If the fill materia( is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
- "compensating volume" wil! be submitted at time of permitting which is prepared by a professiona! engineer
Iicensed by the State of Flarida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fll wi11 be used only to fill the area within the stem wall
- if fil( material is to be used in any area, ( certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit applicati�n, for lots less than one {1}
acre which are elevated by fill, an engineered drainage plan is required.
!f I am the AGENT FUR ThlE OWNER, i promise in good faith to infarm the owner of the permitting conditions set forth in
fhis a�davit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be canstrued to be a Eicense ta proceed with the work and nat as aufhority ta violate, cancel, alter, or
set aside any provisians of the technical codes, nor shall issu�nce af a permit prevent the Building Official from thereafter
reguiring a correction af errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the wark aufhorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandaned far a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, fram the Building Offcial for a periad not to exceed ninety {90} days and will demanstrate
justifiable cause for the extension. If work ceases for ninety (90) consecu#ive days, the job is considered abandoned.
WARNtNG TU OWNER: YOUR FAtLURE TO RECt�RD A NOT'ICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS 70 YOUR PROPERTY. IF YOU INTEND TO OBTAW FINANCING, CONSULT
WITH YOUR�ENDER OR AN AT'FO EY SEFORE RECC}RD1NG YOUR NOTtCE dF COMMENCEMENT.
FLORIDA JURAT(F.S.117.03)
dWNER OR AGENT GONTF2AGTOft
Subscribed and sworn te(ar affirmed)befor me this Subscribed and swom to(or affirm )before me this
i t�-iviay-i� by paul Sweene 76-May-17 by Paul Sweene
Wha islare persanally known ta me or Who istare ersonal3 knawn to e or-tfias!#a�e-pte�e�
...�-.....
as ide tification. ~ as identification.
�� � "' No a P 'c
t ry ubli Notary Public
Gommission No. rF48537 Commission No. FP98537
Elissa M.Holleran Elissa M.Holleran �
Name of Notarv tvaed,printed or stamoed Name of Natary typad,printed ar stamped
,; �� �ll��h���lql��#1 "'�.,� �ll�lh!l.41�1l�k#' __ .
� +�ts�'���n�N�p�t����' `p� ���a��a�a���P��e�?
'� � krp�i�lu[�t��,�6�$
'��Y4�,�'ut�+��'�Qd9 e�id�irar:rc��al��ctts�4�t,31�19 "
�,o-�' lxml�dTlr!'P"G�1�qlt+it1.5d1lS�L71,"r7F�l
,
� ' ° 36041 Stable Wilk Ave-Lennar Home-2833 sq ft
• o umn
' SQ. FEET PRICE
MAIN OR LIVING: 2,833 $ 106.36
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 301,317.88
FEE SHEET $ 1,094.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,195.88
ELECTRICAL: $ 246.15
PLUMBING: $ 164.10
MECHANICAL: $ 114.87
SUB-TOTAL $ 1,721.00
TOTAL $ 7,721.00 I
SEW ER: n/a
WATER: n/a
IRRIGATION: $ -
TOTAL: $ -
WATER METER: n/a
IRRIGATION METER $ -
FIRE DEPARTMENT FEES '
, PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ - n/a
PUBLIC SAFETY IMPACT FEES
POLICE $ 254 00 I
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 2,274.35
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00 N/A
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 11,552.19
� � O'
� Q
' • 4 • '�����
� =-'�`
� �� �' �
. � '��,
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS ,
Contractor/Homeowner: �.`������ �`�'y'�'�`��
----------- — - — -------- -- ----- ---------�
-------- ----- -------- --
Date Received: l` ��--1 r
site: ����G � � ' �'/ 1� I
r
Pernut Type: ��U �')� �� '�'��C ��
i �
;
; Approved w/no comments:❑ Approved w/the below comments:��� Denied w/the below comments: ❑
�
�� f
�
This comment sheet sha11 be kept with the permit and/or plans.
7�r� i �
Kalvin Switzer—Pl aminer Date Contractor and/ r Homeowner
(Required wh,n comments are present)
�
�-
� ' 36041 stable Wilks Ave
. o umn
' SQ. FEET PRICE
UNDER ROOF: 2,833 $ 106.36
' OTHER: - $ _
VALUATION $ 301,317.88
FEE SHEET $ 1,094.00
IADDRESS $ 40.00
DRIVEWAY $ 40.00 �
BUILDING: $ 1,195.88
ELECTRICAL: $ 246.15
PLUMBING: $ 164.10
MECHANICAL: $ 114.87
SUB-TOTAL $ 1,721.00
i TOTAL $ 1,721.00
' SEW ER:
I WATER:
� IRRIGATION: $ -
TOTAL: $ - .
WATER METER:
IRRIGATION METER
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
' PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 2,274.35
PARK IMPACT FEES $ 769.56
' SIF'S: $ 4,828.00 "
� 100.0% $ 4,828.00
1.0°/a $ 48.28 i
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00 ,
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 11,552.19
�
Single Family Dwelling �
Plan Review Comments
1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan.
2. Lots shall be graded to comply with R401.3 of the F.B.C.
� 3. Compaction test required if 24" or more of fill dirt is brought in at any one place.
4. Tie in survey required before pouring concrete.
5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have
expansion material.
6. All setbacks shall be met.
7. All property markers shall be uncovered and marked at time of first inspection.
I 8. All A.D.A. requirements shall be met.
9. No electric,plumbing,mechanical, or framing shall be covered without an inspection and
approval first.
10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).
11. Appliances shall not be installed in a location where subject to mechanical damage unless
protected by approved barriers. M303.4 of the F.B.0
12. Water heaters shall comply with section P607.3 of the F.B.C.
13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1
14. Return air in all bedrooms. F.B.C. M1620.4
15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C.
16. All glazing requirements are to be in accordance with R308.4 of the F.B.C.
17. All means of egress are to be in accordance with R311 of the F.B.C.
18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C.
19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker.
20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating
or appliances or an attached garage. They shall be installed in accordance with the F.B.C.
21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all
underground plumbing and electric.
22. A112008 N.E.C. Codes will be enforced.
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0
; 22. In accordance with the Land.Development Code, lots shall be sodded before final at least 10
feet around the structure.
F.F.E.-Finished Floor Elevation
F.B.C- Florida Building Code 5�'Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008)
� . � � i ii0iii iioii 0iiei iiiii iioii iisii iiiii iiiii iiiio siiii iioi iiii .
. 201711676/
Rcpt:1881928� Rec0.00.00 �
' DS:' 0.00 IT�
• , 07/25/2017 K. M. , Dpty Clerk
�----
PRULR S 0'NEIL,F'h D PRSCO CLERK & COMPTROLLEF
07/25/2017 Q12:40 m 1 �oif 1 _ '
, OR BK ����� P� J2��
Permit No. Parcel ID No 04-26-21-0070-00100-0330
NOTICE OF COMMENCEMEfVT `
State of Florida. - cou�ty or PaSCO
THE UNDER5IGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713, Florida Statutes,
the following information is provided in this Notice of Commencement:
1 Description of Property� Legal SILVERADO RANCH SUBDIVISION PHASES 2,3 &4 PB 73 PG 59 BLOCK 01 LOT 33
StreetAddress 36041 Stable Wilk Avenue Zephryhills FL . 33541
2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence
3. Owner Information: Lennar Homes, LLC.
Name
4600 W C.�[press St Ste 200 Tampa FL. 33607 '
Address City State
Interest in Property•
Name of Fee Simple Titleholder• N�A
(If other than owner)
Address City State
a. contractor� Lennar Homes, LLC
Name
4600 W Cypress St Ste 200 Tampa FL, 33607
Address City State
Contractor's l"elephone No.. $13.574 5700 '
5 Surety� .• . f�l/A _
Name
Address City State
Amount of Bond $ Telephone No
6. : Lender: N�A
Name
Address City State
Lender's Telephone No
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7),Florida Statutes:
� Lennar Homes LLG -
Name
- 4600 W Cvpress St Ste 200 Tampa FI_, 33607
Address City State
Telephone Number of Designated Person: 813 574 5700
8. In addilion to himself,the owner designates N/A °f
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner
9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified:
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF TFiE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE,JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
STATE OF FLORIDA ��
COUNTY OF PINELLAS
re of Owner or Owner's Authonzed Officer/DirectorlPartnerlManager
Vice President �
• Signatory's Title/Office
The foregoing instrument was acknowledged before me this '�6 day of Mafch o ,by ,
Steve RObeft Smith as ViCe Pfesident (type of authority,e. r,trustee,attorney in fact)for
Lennar Homes LLC __�name o y on behalf of insirument was executed)
Personally Known�OR Produced Identification� � Notary Si nature
Type of Identification Rrotluceii'. ' ' Name(Print) issa olleran ' `
Verification pursuant to Section,92.525,Florida Statutes: Under penalties of perjury,I declare that I have read the foregoing and'that the facts stated in
it are�ue to the best of my knowledge and belief. , ,
.�
� ����"'',,� ELI55A�.HOLLERAN Slgnature of atural Person Signing Above
� , s� `;�,,.C�mml�alon�FF885A37 '
� � o' Fxplres June 8,2020
wpdata%bcslbcsform: ,''�P�f`�'', bunda11hm7royFolnlMUAnce100�395-7DiD
, `
.\
�����3�9�� I
� . ° �°<,p �T�7E OF Fi �Rmo, r.�i rwTY clF pa��p �
� THIS IS TO GERTIFY THA7 THE FOREGOING fS A
� � � .' m� TRUE l�ND'CORf�EC1"COPY OF THF DQCUMENT
tnG��eT�t ON FILE�QR;�,QE�pU;. UC�f��G.O,RD!N THIS;OFFICE
�. ' W NESS�Y H�1YV�A 0��f�1�L'�E�1��f��
. {r
�...°...' • —C7�DAY OF
`� `, O , * PAULA S. O'NEIL, ��
a88y &COM ROLLER
� o" s �
�0���g$00�` DEPU Y CLERK
, � � PAS�O �C>l1[VTY, FLt�E�lC►A
� ' ` � Permit No.
, Date Permitted Z Z _,f,�
Builder Name/Owner Nama �d��r� ��C�^� Cantroi#
Gaunty Parcel No. ��—�a—`Z-�—OQ?p..�}ptpp-.p332� SubDiv: J�'� t�_d7�
AddresstLocation 3�pb�� �`��`� ��lt�• `''"""�-
CiassificationtType of Use ��Yt q��Q�.�(�
. '
TRANSPORTATION IMPACT FEE • Rate: Sq.Ft Unit � �.3
Exempt []Yes [] iVo How determined
� Impact Fee Amount $. ��, (r��32� Zone No. TAZ:
SCHO4L IMPAGT FEE
Account (056) Single-Family Detached House Amount $ �, ��.�t �
{057) Moblle Home
{058) Other Res(dentiel
123) Coilection Fee
Exempt [�Yes ❑ No Haw Determined
RARKS AND RECt2EAT1(1N FEE
Land Accaunt Land Ccedit Land Totat
Recreation Account Recreation Credit Recreatior►Tota{
Zone TOTAL AMOUNT $ ��- �S�
Exempt [�Yss [] No Haw Determined
LIBRARY FEE
Land Account Land Credit Land Total , i
Facility Account Faeiifty Gredit Facility Totai �
Exempt ❑Yes ❑ No How Determined Total Amou�
RESOURGE FEE ERU
TOTAL AMOUNT
Prepared By Checked By
NO CERTIFtCATE OF CICCUP'ANCY W{LL BE ISSUED CiR FfNAL{NSPECTfON
PERFORMED UNTiL TNE TOTAL AMOUM7S LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CEN7RAL PERiVIiTTING OFFICE OF PASCO COUNiTY
Ackn,owledgement below does not impiy acceptance of connurrence,but sfmpiy receipt of a capy of this farm,placing
the buifdfng permit owner on notice of this assessment and thQ condittons of payment for same.
DATE RECElVED BY
RECEIPT NO. DATE BY
, --
----r----_�...._.�..:.__._�.�---��-,—______-
.. � ; .
FORM R4�5-2034
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Fiorida Department af Business and Prafessianai Regulation - Residential Perfarmance Method
Project Name. 2386A sf AdS Builder Name: Lennar Hqmes
street: 36041 Stable Wilk Avenue Pem,�t o�ir,e: City of Zephyrhills
Gity,Stata,Zip: ,F�, Permif Number �
Owner• �ennar Homes Jurisdiction: 611600 �
besig�Location: FL,Tampa County:. Pasco(Florida Climate Zane 2)
1 New construction or existing New(From Plans) 9. Wall Types(2570.5 sqft.) Insulation Area
2. Single famiiy or multiple farnily Singte-Family a.Frame-Wopd,Exterior Ft=1'I.0 1285.70 ft2
b.Concrete Block-int Insul,EMerior R=4 1 1118.00 ft'
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 166.83 ft'
4 Number of Bedrooms 5 ���tA R= ft'
5. Is this a worst case? Yes 10.Ceiling Types (1272.0 sqft.) Insulation Area 2
a.Under Attic(Vented) R=30.0 112�.00 ft
6. Conditianed floor area above grade{ftx) 2389 b.3tnee Wali(Ventec3j R=30.0 152.00 ft'
Conditioned flaor area below grade(fta) 0 c.N/A R= ftZ
11 Ducts R ft2
7, Windows{i68.6 sqft.} Description Area a.Sup:Affic,E2et:2nd F{oas,AH:2nd Floor 6 477.8
a. U-Factor Dbl,U=0.54 96.00 ft2
SHGC: SHGC=Q.31
b. U-Factor. DbI,U=d.56 38.68 ftz 12.Cooling systems kBtulhr Efficiency
SHGC: SHGC=0.28 a,Central Unit 42.0 SEER:15.00
c. U-Factae Dhl,ll=0.56 33.33 ftz
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor• N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.397 ft.
Area Weighted Average SHGC: 0.3Q5 14.Hot water systems
8. Floor Types (2389.0 sqftJ Insulation Area a.Electric Cap:4Q gallons
EF 0.950
a.Slab-On-Grade Edge Insulation R=0.0 1269.00 ft2 b. Conservation features
b.Ftaor Over Other Space R=0.0 1124.�0 ft2 Nane
c.N/A R= ft= 15.Credits Pstat
Glass/Floor Area: 0 070 �Qtal Proposed Modified Loads. 7d.83 pASS
Total Baseline Loads: 72.83
l hereby certify that the plans and specificatians covered by Review of the plans and ����T,�r.�, .
this calculafion are in compiiance with tfie Florida Energy spacificatians covered by this �aa�,� '±=�+ Q�,
� Code. calculation indicates compliance ���r�,`;' ;.=.-,��. +s�
� 4::^.:�'d�� '44�'�.
with ihe Florida Energy Code. �- laa�,;_'ix.�;;-�:;�.�+�,t�.t�:
� 4 � ;a
PREPARED BY: ����% ���� Before constructian is compieted w; &;" ` `"�" �
DATE. this building will be inspected for � :"j'.;�" � .
compliance with Section 553.9d8 � � " �
�.. .� -
I hereby certify that this building, as designed, ' in compliance Florida Statutes. r,�,,, , ��..
with the Flarida Energy Cade. �a2?�'•�'�
OWNER/AGENT: BUILDING OF ICIAL. "�
DATE: '' DATE.
- Compliance requires certiflcation by the a handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1. i
-Compliance requires an Air Barrier and Ins ation Inspection Checklist in accordance with R402.4.1.1 and an env�lope leakage i
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Repart confirming duct{eakage to outdoors,
tested in accordance�with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whale hause. �
�. �
6/12/2017 3:02 PM EnergyGaugeOO USA-FlaRes2014 Section R405.4.1 Cornpliant Software Page 1 of 5
J
�. 1 �
FORM R405-2014 ,
� FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 2386A sf ADS Builder Name. Lennar Homes
street: 36041 Stable Wilk Avenue Permit ot�ice: City of Zephyrhills
City,State,Zip: ,FL, Pertnit Number
Owner• Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa � County:: Pasco(Florida Climate Zone 2)
1 New construction or existing New(From Plans) 9. Wall Types(2570.5 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1285.70 ft'
b.Concrete Block-Int Insul,Exterior R=4 1 1118.00 ftz
3. Number of units, if multiple family 1 c.Frame-Wood,Adjacent R=11.0 166.83 ftZ
4 Number of Bedrooms 5 d.N/A R= ft'
10.Ceiling Types (1272.0 sqft.) Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1120.00 ft2
6. Conditioned floor area above grade(ftz) 2389 b.Knee Wall(Vented) R=30.0 152.�0 ftZ
Conditioned floor area below grade(ftZ) 0 c.N/A R= ft=
11 Ducts R ftZ
7. Windows(168.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 477.8
a. 11-Factor Dbl,U=0.54 96.00 ft2
SHGC: SHGC=0.31 �
b. U-Factor Dbl,U=0.56 38.68 ftz 12•Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.28 a.Central Unit 42.0 SEER:15.00
c. U-Factor: Dbl,U=0.56 33.33 ftZ
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor N/A ftZ � a.Electric Heat Pump 42.0 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.397 ft.
Area Weighted Average SHGC: 0.3�5 14 Hot water systems
a.Electric Cap:40 gallons
8. FloorTypes (2389.0 sqft.) Insulation Area EF 0.950
a.Slab-On-Grade Edge Insulation R=0.0 1269.00 ft= b. Conservation features
b.Floor Over Other Space R=0.0 1120.00 ft' None
c.N/A R= ftZ 15.Credits Pstat
Glass/Floor Area: 0.070 Total Proposed Modified Loads. 70.83 PASS
Total Baseline Loads: 72.83
I hereby certify that the plans and specifications covered by Review of the plans and ����T`�g?.
this calculation are in compliance with the Florida Energy specifications covered by this � '�,�'��t7,�,,,,
Code. calculation indicates compliance � ���r„l�;'� ,._,��.�`.y�,
`� 1 r, t11�7 ` �"t�:�-•• a\`
with the Florida Energy Code. ,� �u..,;:.:;,t��,,,,, .O.
PREPARED BY. �aV� ����� Before construction is completed w� �;, �
��',.:, � • �
DATE: this building will be inspected for �. 1,,;��;, :� .
compliance with Section 553.908 .* �'°:� �
I hereby certify that this building,as designed, is in compliance Florida Statutes. t,�; ,, ����.. �
with the Florida Energy Code. �'flT�.WE'�
' OWNER/AGENT: BUILDING OFFICIAL: -�
DATE. DATE: �
- Compliance requires certiFcation by the air handler unit manufacturer that the air handler enclosure qualifies as
� certified factory-sealed in accordance with R403.2.2.1. •
� -Com liance re uires an Air Barrier and Insulation Ins ection Checklist in accordance with R402.4.1.1 and an envelo e leaka e
i P q P • P 9 i
, test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards,is not greater than.0.030 Qn for whole house. �
6/12/2017 3:02 PM EnergyGaugeO USA-FlaRes2014 Section R4�5.4.1 Compliant Software Page 1 of 5
, , .
� , , `
FORM R405-2014 '
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
' Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 2386A sf ADS Builder Name: Lennar Homes
street: 36041 Stable Willc Avenue Perr„�t ot�ce: City of Zephyrhills
City,State,Zip: ,FL, Permit Number
Owner Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2)
1 New construction or existing New(From Plans) 9. Wall Types(2570.5 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1285.70 ft'
b.Concrete Block-Int Insul,Exterior R=4.1 1118.00 ft2
3. Number of units, if multiple family 1 c.Frame-Wood,Adjacent R=11.0 166.83 ft'
4. Number af Bedrooms 5 d.N/A R= ft�
5. Is this a worst case? Yes 10.Ceiling Types (1272.0 sqft.) Insulation Area Z
a.Under Attic(Vented) R=30.0 1120.00 ft
6. Conditioned floor area above grade(ft2) 2389 b.Knee Wall(Vented) R=30.0 152.00 ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft�
11 Ducts R ftZ
7 Windows(168.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 477.8
_ a. U-Factor: Dbl,U=0.54 96.00 ftz
SHGC: SHGC=0.31
b.��U-Factor Dbl,U=0.56 38.68 ft' 12.Cooling systems kBtu/hr Efficiency
" ' SHGC: SHGC=0.28 a.Central Unit 42.0 SEER:15.00
c. U-Factor• Dbl,U=0.56 33.33 ft'
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.397 ft.
Area Weighted Average SHGC: �.305 14 Hot water systems
8. FloorTypes (2389.0 sqft.) Insulation Area a.Electric Cap:40gallons
EF 0.950
a.Slab-On-Grade Edge Insulation R=0.0 1269.00 ft� b. Conservation features
b.Floor Over Other Space R=0.0 1120.00 ftZ None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area. 0.070 Total Proposed Modified Loads. 70.83 pASS
Total Baseline Loads: 72.83
I hereby certify that the plans and specifications covered by Review of the plans and 0����53��� .
this calculation are in compliance with the Florida Energy specifications covered by this � ,�i,� � _.��, p�,
Code. calculation indicates compliance �'�ri„ "'�, �°�`.��t��
/,� /' with the Florida Energy Code. �+ <rrror��'r;`:`�:=;.;'.�+�,ti�O.
PREPARED BY: �aV� �GUL{'l�VL Before construction is completed � ;, � �""�" �
5
DATE. this building will be inspected for �. . ""�`�' " �+�
'.��'.
compliance with"Section 553.908 * 'Q ,�
I hereby certify that this building,as designed, is in compliance Florida Statutes. e�^11, ����- �
with the Florida Energy Code. ' GOl)WE'�
OWNER/AGENT: BUILDING O CI L.� '
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope-leakage
`test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house.
6/12/2017 3:02 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
� .
FORM R405-2014 � '
� PROJECT
Title: 2386A sf ADS Bedraoms: 5 Address Type: Street Address
Building Type: User Conditioned Area: 2389 Lot#
Owner Lennar Homes Total Stories: 2 Block/SubDivision:
#of Units: 1 Worst Case: Yes PlatBook: I
Builder Name: Lennar Homes Rotate Angle: 0 Street:
Permit Office: Cross Ventilation: County Pasco I
Jurisdiction: Whole House Fan: City,State,Zip:
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Block1 2389 19873.4 '
SPACES �
Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated II
1 1st Floor 1269 10913.4 Yes 2 1 1 Yes Yes Yes
2 , 2nd Floor 1120 8960 No 4 4 1 Yes Yes Yes
FLOORS �
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio 1st Floor 121 ft 0 1269 ftZ ___ 0.3 0 0.7
2 Floor Over Other Space 2nd Floor __� _� 1120 ftZ 0 0.2 0 0.8
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 1213 ft' 0 ftZ Medium 0.85 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1120 ft2 N N
6/12/2017 3:02 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 2 of 5
� .
FORM R405-2014
� CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) 2nd Floor 30 Blown 1120 ft� 0.11 Wood
2 Knee Wall(Vented) 2nd Floor- 30 . Batt 152 ftZ 0.11 Wood
• WALLS -
Adjacent Spa� Cavity Width Height Sheathing Framing Solar Below
1 N Exterior Concrete Block-Int Insul 1st Fioor 4.0999 10 8 8 86.7 ft2 0 0.600000 0
2 E Exterior Concrete Block-Int Insul 1st Floor 4.0999 52 8 8 450.7 ft2 0 0.600000 0
3 S Exterior Concrete Block-Int Insul 1st Floor 4.0999 30 8 8 260.0 ft2 0 0.600000 0
4 W Exterior Concrete Block-Int Insul 1st Floor 4.0999 37 8 8 320.7 ft2 0 0.600000 0
5 N Garage Frame-Wood 1st Floor 11 19 3 8 8 166.8 ftz 0 0.01 0
6 W Exterior Frame-Wood 1 st Floor 11 14 6 8 8 125.7 ftZ 0 0.01 0
7 N Exterior Frame-Wood 2nd Floor 11 18 6 8 148.0 ftZ 0 0.600000 0
S E Exterior Frame-Wood 2nd Floor 11 52 8 416.0 ftZ 0 0.600000 0
9 S Exterior Frame-Wood 2nd Floor 11 30 8 240.0 ft= 0 0.600000 0
10 W Exterior Frame-Wood 2nd Floor 11 44 6 8 356.0 ftz 0 0.600000 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N Insulated 1st Floor None .2 3 6 8 20 ft2
2 N Wood 1st Floor None .4 2 8 6 8 17.8 ftZ
WINDOWS
Orientation shown is the entered orientation(_> chan ed to Worst Case.
/ Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N 1 Metal Low-E Double Yes 0.56 0.28 6.7 ftZ 6 ft 0 in 0 ft 2 in Drapes/blinds None
2 E 2 Metal Low-E Double Yes 0.54 0.31 16.0 ftZ 1 ft 0 in 10 ft 2 in Drapes/blinds None
3 S 3 Metal Low-E Double Yes 0.54 0.31 16.0 ft� 1 ft 0 in 10 ft 2 in Drapes/blinds None
4 S 3 Metal Low-E Double Yes 0.56 0.32 33.3 ft' 2 ft 0 in 0 ft 11 in Drapes/blinds None
5 N 7 Metal Low-E Double Yes 0.56 0.28 16.0 ft' 1 ft 0 in 0 ft 6 in Drapes/blinds None
6 E 8 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None
7 S 9 Metal Low-E Double Yes 0.54 0.31 16.0 ft� 1 ft 0 in 0 ft 6 in Drapes/blinds None
8 W 10 Metal Low-E Double Yes 0.54 0.31 32.0 ftZ 1 ft 0 in 0 ft 6 in Drapes/blinds None
9 N 7 Metal Low-E Double Yes 0.56 0.28 16.0 ft' 1 ft 0 in 3 ft 0 in None None
GARAGE
# FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 414ft2 414ft2 45ft S.6ft 1
6/12/2017 3:02 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Sofiware Page 3 of 5
. , .
FORM R405-2014
' INFILTRATION
# Scope Method SLA CFM 50 ELA EqLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .00037 231 S.6 127.29 239.38 .3416 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump None HSPF:8.5 42 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 15 42 kBtu/hr 1260 cfm 0.85 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
� 1 Electric None Garage 0.95 40 gal 90 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft'
DUCTS
/ —Supply— —Retum— Air CFM 25 CFM25 HVAC#
\� # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 477.8 ft 2nd Floor 119.45 Prop.Leak Free 2nd Floor —cfm 71.7 cfm 0.�3 0.60 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Coolin Jan [ ]Feb [ ]Mar A r Ma [X]Jun [X]Jul Au X Se [ ]Oct [ ]Nov Dec
Heating �Jan [X]Feb [X]Mar E �Apr f �May [ ]Jun [ ]Jul ��Aug 4 �Sep [ ]Oct [X]Nov Dec
Ventin Jan [ ]Feb [X]Mar [X A r [ Ma [ ]Jun [ ]Jul Au [ Sep [X]Oct [X]Nov Dec
6/12/2017 3:02 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Sofiware Page 4 of 5
, , .
FORM R405-2014 -
Thermostat Schedul€: HERS 2006 Reference . Hours
Schedule rype 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 SO
- PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 _ 78, 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
6/12/2017 3:02 PM EnergyGauge�USA-FlaRes2014 Section R4Q5.4.1 Compliant Software Page 5 of 5 I
, I
, � ' "
FORM R405=2014
� ENERGY PERFORMANCE LEVEL (EPL)
. DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index,the more efficient the home.
, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1285.70 ft2
b.Concrete Block-Int Insul,E�Aerior R=4 1 1118.00"ftz
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 166.83 ftZ
4 Number of Bedrooms 5 d.N/A R= ft�
5. Is this a worst case? Yes 10.Ceiling Types Insulation Area 2
a.Under Attic(Vented) R=30.0 1120.00 ft
6. Conditioned floor area(ft�) 2389 b.Knee Wall(Vented) R=30.0 152.00 ft'
, 7 Windows*' Description Area c.N/A R= ftzZ
a. U-Factor• Dbl,U=0.54 96.00 ftz �1 Ducts R ft
a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 477.8
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 38.68 ft'
SHGC: SHGC=0.28 12.Cooling systems kBtu/hr Efficiency
c. U-Factor• Dbl,U=0.56 33.33 ft' a.Central Unit 42.0 SEER:15.00
SHGC: SHGC=0.32
d. U-Factor: N/A ftz 13.Heating systems kBtu/hr Efficiency
, SHGC: a.Electric Heat Pump 42.0 HSPF:8.50
Area Weighted.Average Overhang Depth: 1.397 ft.
� Area Weighted Average SHGC: 0.305
8. Floor Types Insulation Area 14.Hot water systems Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1269.00 ft� a.Electric EF 0.95
b.Floor Over Other Space R=0.0 1120.00 ftz
c.N/A R= ftZ b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building ;��Esx
Construction through the above energy saving features which will be installed (or exceeded) ,�,�� _.'�?'�o. �
in this home before final inspection. Otherwise, a new EPL Display Card will be completed -:�k�"�keJrrrl^�, ,%;i�°;�_�,
based on installed Code compliant features. � f+rt % � ,.���=`„ o�
c�. - .:
� _.H,yk •.. �-,. �
Builder Signature: Date. 06/13/17 � ���y� � -
„ � Q . :.
Address of New Home. 36041 Stable Wilk venue City/FL Zip: Zephyrhills,FL33541 �� ' ��`�' '
. OXj_'yVE'�`
*Note: This is not a Building Energy Rat g. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain Florida EriergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/12/2017 3:04 PM EnergyGauge�USA-FlaRes2014 -Section R405.4 1 Compliant Software Page 1 of 1
f � � �
Buildin Anal SIS Job: 2386AsfADS �
g Y Date: 6/73/2077
Entire House By: Dave
Bayonet Plumbing Heating and Air
� . . �
For: w Lennar Homes
! - o � • �
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD (°F) 39 16
Latitude: 28°N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7
Dry bulb(°F) 31 91 Infiltration:
Daily range(°F) - 14 ( L ) Method Simplified
Wet.bulb(°F) - 77 Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
•
Component Btuh/ftZ Btuh % of load
Walls 4.7 11717 35.9 ��5
Glazing 30.2 5134 15.7 I
Doo�s 23.5 466 1.4 wa�s nfi�vauon
Ceilings 1.3 1611 4.9
Floors 4.0 5059 15.5
Infiltration 1.7 4583 14.1 �
D ucts 4026 12.4 ,
Piping 0 0 Fioo�
Humidification 0 0
Glazing Ceilings
Ventilation 0 0 ome�
Adjustments 0
Total 32596 100.0
• • •
Component Btuh/ftz Btuh % of load
Walls 2.8 6888 22.1
Glazing 46.4 7886 25.3 Walls Intemal Gains
Doors 18.4 365 1.2
Ceilings 1.7 2175 7.0
Floors 0 0 0
Infiltration 0.4 1021 3.3 1 ,
D ucts 4488 14.4
Ventilation 0 0 i
Internal gains 8290 26.6 oucts
, BIOWEf 0 0 Glazing
Adjustments � ocner Ceilirinfiltration
Total 31117 100.0 gs
Latent Cooling Load= 5526 Btuh
Overall U-value= 0.117 Btuh/ft2-°F
Data entries checked.
,�. wri htsoft` 2017-Jun-13 OB:22:31
�A9 Right-SuitetA Universal 2017 17.0.23 RSU05714 Page 1
..th CBA27UHE AH's\2386A sf ADS drawn 3.5 ton.rup Calc=MJ8 Front Door faces: S
Pro ect Summa1�' Jo6: 2386AsfADS
1 '7 Date: 6/1 312 0 1 7
Entire House By: Dave
Bayonet Plumbing Heating and Air
' a - s •
For: Lennar Homes
Notes: -
! - � • •
Weather: Tampa InternationalAP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 °F Outside db 91 �F
Inside db 70 °F Inside db 75 °F
Design TD 39 °F Design TD 16 °F
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 28570 Btuh Structure 26624 Btuh
Ducts 4026 Btuh Ducts 4488 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 32596 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 31111 Btuh
- Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 4718 Btuh
Ducts 808 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling (none)
Area(ftZ) 2389 2389 Equipment latent load 5526 Btuh
Volume(ft') 22784 22784
Air changes/hour 0.28 0.15 Equipment Total Load (Sen+Lat) 36638 Btuh
Equiv.AVF (cfm) 106 57 Req. total capacity at 0.85 SHR 3.1 ton
Heating Equipment Summary Cooling Equipment Summary
Make Lennox Make Lennox
Trade 14HPX SERIES Trade 14HPX SERIES
Model 14HPX-042-230-21 Cond 14HPX-042-230-21
AHRI ref 10258591 Coil CBA27UHE-042-230*++TDR
AHRI ref 10258591
Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER
Heating input Sensible cooling 36975 Btuh
Heating output 43500 Btuh @ 47°F Latent cooling 6525 Btuh
Temperature rise 28 �F Total cooling 43500 Btuh �.
Actual air flow 1400 cfm Actual air flow 1400 cfm
Air flow factor 0.043 cfm/Btuh Air flow factor 0.045 cfmlBtuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio - 0.85
Capacity balance point=24°F
Backup: n/a n/a
Input= 0 kW, Output= 0 Btuh, 100 AFUE '
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
� WI'1 �'1tS0'�° 2017ti1un-13 08:22:31
g Right-SulteC�Universal 2017 17.0.23 RSU05714 Page 1
� ...th CBA27UHE AH's\2366A sf ADS drawn 3.5 ton.rup Calc=MJB Front Door faces: S
� Job: 2386A sf ADS
Manual S Compliance Report Date: 6H3/2017
En tire Ho use By: Dave
Bayonet Plumbing Heating and Air
' s - s •
For: Lennar Homes �
. • . . �
Design Conditions
Outdoor design DB 91.3°F Sensible gain: 31111 Btuh Entering coil DB 75.6°F
Outdoor design WB� 77.3°F Latent gain: 5526 Btuh Entering coil WB� 62.8°F
Indoor design DB� 75.0°F Total gain: 36638 Btuh
Indoor RH. 50% Estimated airtlow• 1400 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Lennox Model: 14HPX-042-230-21+CBA27UHE-042-230*++TDR �
Actual airflow: 1400 cfm
Sensible capacity: 35700 Btuh 115% of load ,
Latent capacity: 6300 Btuh 114% of load
Total capacity' 42000 Btuh 115% of load SHR. 85%
• e o
Design Conditions
Outdoor design DB. 30.8°F Heat loss: 32596 Btuh Entering coil DB. 69.7°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: SpIitASHP
Manufacturer: Lennox Model: 14HPX-042-230-21+CBA27UHE-042-230*++TDR
Actual airtlow: 1400 cfm
Output capacity: 42000 Btuh 129% of load Capacity balance: 24 °F
Supplemental heat required: 0 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer� n!a Model: n/a+n/a '
Actual airtlow: 1400 cfm
Output capacity: 0 kW 0% of load Temp. rise: 0 �F
Meets are all requirements of ACCA Manual S.
.., wri htsoft'� 2017ti1un-13 08:22:31
�. � 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1
�'� ...th CBA27UHE AH's\2386A sf ADS drawn 3.5 ton.rup Calc=MJB Front Door faces: S
" SKETCH ONLY SEC. 04 , TWP. 26 S, RNG. 21 E.
PLOT PLAN NOT A BOUNDARY SURVEY
LOT 33, BLOCK � BEARING BASIS:
SILVERADO RANCH SUBDIVISION NOR.TH BOUNDARY OF SE� OF OS-26-21 BEING N 89'25'01" E
PHASES, Z, 3 8C 4 THIS SURVEY IS SUBJECT TO ANY FACTS 7HAT
PASCO COUNTY, FLORIDA. MnY BE DISCLOSED BY A FULL AND ACCURATE
'� T T1TLE SEARCH. ALSO SUBJECT TO SETBACKS,
ON LOT AREA CALCULATIONS l� EASEMENTS AND RESTRICl10NS OF RECORD_
LOT = 6561.73 $Q, F"�', UNDERGROUND FOOTER, STEM WALL, AND
LIVING AREA = 1269 SQ. �. o UNDERGROUND UTILITIES ARE NOT LOCATED OR
ENTRY = 51 SQ. FT. M SHOWN.
GARAGE = 4�4 SQ. FT.
COVEREO LANAI = N A SQ. FT. _�� DO NOT SCALE THIS PRINT. DIMENSIONS AND
PAT10 = N A SQ. FT. � NOTES TAKE PREFERENCE.
POOL AREA = N A SQ. FT. w
CONC. DRIVE = 361 SQ. FT. Q DESCRIPl10N NOT CONTAINING PLAT BOOK AND
A/C & CONC PAD _ 35 SQ. FT. � PRELIMINARY ASTAGE AND ISL SUBJECT ITO
PRIVATE SIDEWALK
IMPERVIOUS = 2142 SQ �T CHANGE AND/OR REVISION.
SOD = �-�9 SQ. FT. CERTAIN DATA SHOWN HEREON BASED ON
OFF LOT AREA CALCULATIONS ENGINEERING PLANS PROVIDED BY CLIENT.
RIGHT OF WAY = 948.92 SQ. FT. STRUCTURE T1ES SHOWN HEREON DENOTES
DRIVE APRON = 233 SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNOATION
FUBLIC SIDEWALK = 266 5Q. FT. TO PROPERTY LINE.
SOD = 450 SQ. FT.
YOTALS ■ = 10' UTILITY EASEMENT
AREA = 7510.65 gQ, F1',
DRIVEWAY = 594 SQ. FT.
SIDEWALK = 301 SQ. FT. � PRM(P)
SOD = `�869 SQ. FT. ZEPHIRHILLS COLONY COMPANY o
(PLAT BOOK 1, PAGE 55) `^ _
PRELIMINARY DRAWING: ,9 30,. E 6263 \s.ss'
THIS PLAN IS FOR PERMITfING PURPOSES , : �
ONLY, NOT FOR CONSTRUC110N. VERIFY N �`� �
ALL DIMENSIONS BEFORE ANY CONSTRUCl10N. r�O23� W
LEGEND: ,� LOT 33 w �
_T�= PROPOSED DRAINAGE FLOW � '� • 'o. BLOCK 1 "� N •
(00.00) = PROPOSED GRADE � � '��;s,, ��, '._ �U'
E-00.00 = EXISl1NG GRADE PLAT � '_ �y •� .
NOTES: BOUNDARY J.9 C _ W
AI � N
�A.94
LOT GRADING TYPE = A/B •� o
PROPOSED PAD ELEVATION = 102.1' �
FRONT SETBACK = 20' or 22' m
SIDE SETHACK = 7.5� �49� N�p9�^,E
REAR SETBACK = 15' Z LOT 32
�, PROppSED N BLOCK 1
o pIPN �
o z� 23g6 � N �
rn, N�p ELE� '� �, N
LOT 34 z � 1 GARA
BLOCK 1 �,0: �EF7
f
N ' `
W l �
1 1264 '
12 64' 16.00� ° �� ' �.
. ` � N� �1
- • N �N�W� � b
� �N cP W e p� .�.
N�i p,a� •N �iF ` � '
i��
16 0�•� •"
(lp� �
� • C93�oj a ,Cg2 .
a . �<o v. < ' "'
� � �
,� o�
.o
n ' �n 20.00� N
� �''v'• -
n •� �o. .r
� ��;. � pCP�P� ; P ENVE
�
`° � NI��-� �� ��
a' . R�� ,N� (SRA
r�i S��V (6p'R�
� DESG�2IPTION:
Y LOT 33, BLOCK 1, MAP OR PIAT ENTITLED "SILVERADO OWEST���OOR ELEVATIONS:
m RANCH SUBDIVISION PHASES -2, 3 & 4", AS RECORDED IN LIVING AREA: 102.80'
� PLAT BOOK 73, PAGES 59 THROUGH 65, OF THE PUBLIC GARAGE AREA: N/A
M RECORDS OF PASCO COUNlI,', FLORIDA. ELEVATIONS REFERENCED TO
4- CURVE RADIUS ARC . CHORD BEARING DELTA NORTH AMERICAN VERTICAL
= csz sss.00' S3.44' 53.43� s �ros�o2�� w o4•as�is�� DATUM OF 1988. MEAN SEA
c� C93 665.00� 6.08' 6.08' S 7435'12' W 0031'25" LEVEL= 00.00 FT.
z
�
� APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL N0. 120230 0455 D EFFECTIVE DATE: 09/30/1992
0
0
� LEGEND:
> (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, �= CENTERLJNE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
N CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN UNK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
= F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED I
� PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, P6= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
Q REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK,
� U P= UTILITY POLE W F= WOOD FENCE, R = RADIAL
� JOHN R.BEACH&ASSOCIATES�INC. Drawn By. Square Feet: 6561.73 t LENNAR HOMES
• Q SMS
w � SURVEYORS AND MAPPERS Checked B
� 911 WEST ST. PETERSBURG DRIVE Y JRB
in OtJE OLDSMAR, FLORIDA 34677
N WAY (g�3) 854-1276 FAX (813) 855-8370 Scale: ,,,_30,
c (� �Zd
0
•� NOT VALID WITHOUT THE SIGNATURE AND Date:
� THE ORIGINAL RAISED SEAL OF A FLORIDA PLOT PLAN 06/07/2017 RTM H . BEACH DATE
� LICENSED SURVEYOR AND MAPPER FLORID EG. LAND SURVEYOR No. 2984 LB#4493
�
/ Revisions:
�
�
i.�.--- - � - - -- �`�Jv-' vT.- �rsJ � ..b 1`5- . . ._ -
`,��__ -__�� ' ' J`�.•___ _� �_ '_ '�,-_ _ ' ^ ��O .rq i 'n ' T - -��J �T � �T °•Y '_ \ ` � S}{o90�j2 ; ��
� O , � -
n
. ��C�• , �� � �� � '`, ^ Gj p� �7 �• �:.g � r. s `p�� NP-�
i 0 i . O ie '- " �
D�`' � `,I• 7.� 1 .1�\ T1� �O�'- , ,SG` (j� Q ��� O Q `--�"J' y,� '• �� �- \l�c'' �- ",
O r� '
r . �
,0 � �� ,1 _�� ''�� -,-g� • •a� �( - ' „ ��`°�r°`� TJv T���`�'' "y� -_ ' �y � ',�'�
G�� ' O� - ' � I ' ��°'�- _ •\k c� �� �c�3 � * .
;�a� �. . - . , ���� �° �i�'` ,� T� --- , - "}a. �. -_ �` a� .
0� c -r�0 • - o,aT�a . - _�Cti�. �-� � __ ,3- „- ��;`��� .�.�'�1-' ----- �
• Q� ,• n O ay � 1 1 ia'. �` �R� _-•� O+�
i�v� `��` '1 p�`� b" �• `.1.� ��f�" �:.�, g'1 0�-�`' _ - . _'-a ,-� �" � �O`� ��°�; ,
�J � _\V,- O„�O c`� _,�� _�C�1 �,\.�. _�� �, - ;g�°� �v��%� ��' -'-o-,�.. - - - • . � .- ro�24. • �� ``r�� .
��` ��° ��, y1 • '� o �� ,�� p� � ' '_- . ` a '1� � ��_ �� ����_ �
-•� � � ° � ----- �-�---- '�� °�} � � � e � �` - `�' � �"�--
'- •,�-0'p.°.a.a.a•, _c,} •%,ro. � _� • _ _ ,�3 -i- � o� -••� -�� ���'• '
•. G � ' , �o.o•o• , �, - ,�c� Q�� � -- '\��_�-c.4,, . , .
�7=5 h� • o.a:o.o• , �, - � �.
` � O- ��o, „ a-a•°;. _��-- ' . � , _ ' 1 �5• �, '- � � �xs-��
�� � , �1 ��j� �`Z �o�o�O� ,7� �' G,« S c� g� � , � • ��
a, .��x.J ��� -:-1� -� .a°�' ��� �C ,1 C' ���" � �_ �� �. -37 � ,, c�" _ - � C� e` ,
.a•a- °p _� - i - � '(g T" „ g `
' ,- -� •a;o•O�D ' _ � ,� o� - _ _�� � "5 Q5' 1� ,a�' ' -� ``� /
� �\ G.�� �`G,�` ���.a��b�k � � i.�t C �1 ,� � �� ���� _ =1.Dc?�LQ �tOA:ba 4 90 - a ��� �"ac' _ ��� �
�, ' Zj�� �0(9•o-a'�, � ;1� r\ _ �1 �, . FF=1�2.1 LO'I' 31 PA�9�9 "qT 29 FF=99.70 . �� ' " "5 �
C� O� � `
` a �, ��j � LOT 32 PAD=190.4 PAD=99.2 LOT,� � 30A ,u
��a� -. r LOT`?73 �.' FAD=101.4 ' TYPE B �TfJ?E B TYPE��B. P , 49.0 FF-99.70, � _ �G - �� ���
� �� FF=104.fl PD(9=1021 �E A/B _n . ' .
w E B LOT 27 „ �ro. �
� s LOT 34 '1�"fPE A �.� � PAD=99.0 '•9 1 � . - .�\ ��
� �� . FF-105_ AD=103�,3 . � _ cJ� _ 7YPE B =99_ - '' [t c�_•� ��
�� �\ _ LOT 35 rrPE a o __ __ '`---�- � ---- - �-____�` _ �,� �a��z� .�;�� ^- a , .� � �,
� FF-t�6.b AD 104.8 � _� Ll ;�SEM �- __ ��.� PA9`=9Ei9 �.a�a , , ;� "j
� �� � LOT `36 `', TYP�FJ A � � - o' � - 983a� - ,c� • TYPE B� � ',-_ , ,
O -c �Q'� PA�=1 Q,`L�. �0 � �'1 , '1� �, � �y � � ��^. 1 �� 98.18� .__ f��E 4�g.7 � �� ;�'�,
� � nP[-�'1� ,\C� �' �✓ � .'�� �1G �\• i V �i.� � �A �� / .
�� � � , �"� �-�,a _�� _ '�• .� s ,o ' ,�3 �', _ ��
� , _�O o 1�- ; _ 1s � ro. , �• ' 1.° '_�6- °�
� \ , Y� �� �� � ��� �� �•, .
\\ ��\ -'� ' � o� �� � 1� � ^ � O � Q J * FF=99. 6L5 � �y �� -
` „ `o rn ,, ; 5.g LaT �; ,g -
i � ,� � �o ' � � � , � ', PAD�8.9 � -
6 . r' �\C ' J,�� ..� � , -�� _ -�� ^r _� ----- - +�--- __ ➢ �0 ��` TYPE 8 �P _ 8 � _ ;c.1
�. � D - g -_ � '� � � _
�, � ' -� �,� - . •� ,� '; ;� � ' _ 0 � �-� '•7 6 .0)�' •
�v �h. ' .� ; , - '' �� 1 '� O ,,�A, �•, �� - ,
,.,-�' ��J `� ta U�' °J , �� � `F=101_70 '�FF=100.90 �09.20 � +9� � 9�� a� � ��
� ' � '�p� p`�.' FF=10 ;, LOT 1 1 ' LOT 10 LOT 9 '� � 5� � ' - ' i
PAD=100_ � . .. i .n� � t
• o - , - - �-'� LQ�F. 12 ATYPE �� TYPE A ~ PAD=99_5 F=100_2Q � 91 '` ' ' C,�j� _' `�
F�=103.6 PA0=T0.1_9 .� i � � A LOT, 8 ,`] ' -�-� � _ „- a,�+
�� t°� . � � L0� 13 TYPE AO_ � \V� Q�, Pa,D=99.5 � � � ��ft-99.70 - � �����)a
�� � FF=105.0 _AQ 1�02.9 _�'� n2� A � -- '
` �� LOT 14 „ '�YPE�;A < <_ � g�� i ((� '1 1 y�1 LOT 25 �i�
i^ , � FF=106_4 AD=104.3 ;•� 0� �'� � . g.2 PAD=99_0 G, �
��1 � � $• ' �F B Dc;�
+� ,r
� � LU� 15 TYPE A �.� � ' ' ,. ', __�� � � •,, � �,r
v. b \ AD=10.rq.7 . ..• '' T _,\ 8 , j �-q ' ��2 ,\ � � � �� , ,c��j• ,
� ^ c`� - � � � ^- , _ � ,
'��� � �tib ro - �o.� ���� �• , ��`• U35 _fi �'r � �� �' ���- . r
''-1� _ �1 �,l , ;� ' ,` � D� , r � �� J�4 L�� FF=1Qa.30:1 . g.1 - - �1 +� m A ia- J
'` `` 7 , �o v� O �• �-`'�'• LOT 24°�', �� G ;
_ti o • ' L•., r � 6 PAD=99.6 �afo � a�' , 6 _ i ��'x �
� a.`Y 4� s• , , '� 7\ � 'i1 i� 1 TYPE B 1�j a.� - 5`. i "�w
` `G,� ' c 1 M =��$.70 �=��$.�� �'. !h ;� `1 .'V _ , • le'l,y r`I
� � ,
1 �� ' ��� .6 � p'I° � 1� d FF=t 06.2 �' � LOT 5 LOT 6 =t 0�:�0 ;•J � � �, • _ �'i ct '
�� � - LOT 4 � PAD=105.fl o � , , , � �, �.�
,' ,� � � 6 '� ' - FF=107_ PAD=105.� „Q,'(PE B � PA6=104.3 LOT 7', i� � ' � , - 1�� _ �i•, m .:
� �� �- • ' � LOT 3 TYPE 9 • .��B PAD=1�fi o� i �� � �r 1 FF=102.40 9. • ���� I
`°� ��.�� �'�"� a, FF=107_7 AD=106 `� � TYP � � °' , Y� LOT 23 -_ , a, � � �
�� O^, C �1 �j�`' �'� `7'' ,��y LOT•2 TYPE 8' va "��� ' - i��� �/�' �` ' 9 .e P 100�.7 ,n�" �`� , o.a
�� o �T'� _ �'� , FF='rETB.fl AD 107i:a � � � `�� � Q _� � ��U
1 1 LoT � �� e. __ ----� _ �Q'_ •-, '�� �° �
� �, l� Pkb=107.3 ' �� _ ' _�~ ,O - ' � � �� � , ��
� ,� 1 � •7YPE 8 r� I,__'' '' � `� 1 r , � 1 � =�p.b��
,�� 1 � ENT _ - Dc �O r �1.02.30 `Oj '
� t � „c� - � � ^� .. . . � ., .. . 7�c• oo. �`
� y .
�
� �
I � " _"" ' ' _'" ' ,._—_ _`— " ' "__' '__'"_" __.. ...�_'""' _'_"_____'_'_' _".' " _ __
'c' ."
' . � , (,�Crystal Reports Viewer-Intemet Explorer - _ _ _ -- '_:�::_�-�
;... --- -- - --- —--- ----.. _ . ._. - ------- - - -----�- -- ---
- ------ ------- ---
; � -- -- --- - - --- auuezau -- - u I
� New Pod Richey,FL 34654 , I
{ 727-847-8127 � I
� , �
` � �� �9�T A PERMIT �`�` ;
I Receipt# 1718792 ��-
� �
;
� s �
' FEE UESCRIPTIOPJ ACCOUNT CODE UNITS ItdV010E# FEE AP90UIJT PA1D RECEIPT# DI` !`
!i
� Impact Fee Residential Solid 24503100-329010 10.03 1298865 �10.03 $10.03 1718792 11l1?; !�,
� Waste Single Famiiy �
�
711�LS SOLm WASTE. � ;i;
i
� TOTALS: $10.03 $10.03 '�
(
� Receint# Paid Check# CC Auth# Cashier ID Workstation Receint Date A! ;"
,� 1718792 Check 20290 294 BCCCP38W 11/13/2017 + �
i �
� Total Payments: j ;i,
� ��.
' Pavor Address Phone ,
, LENNAR HD�v1E5 36041 STABLE WILK AVE. 8133632891 ,
IComments 'i '
� 36041 STABLE WILK AVE ZHILLS FL ��
i 0426210070001000330 � j;
iPn18697 ;�
, SOLID WASTE
i �
� i
i ; I
; �
I � �I
� �
I
i '� ':
� _ _ '" _�"_ ' _ " _ ...__ _ '"_' _ '__ `_` _'"__"_" "".�—__'__ _ �_ _" ._'"_ '
j � I
_ _ - �i Z�Q�o � .
�