Loading...
HomeMy WebLinkAbout17-18699 CITY OF ZEPHYRHILLS ' • � 5335-8TH STREET (sis)�so-oo20 18699 Bl3ILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION . Permit#:18699 Issued: Address: 6502 PADEN WHEEL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR � Township: Range: Proposed Use: NOT APPLICABLE _ Lot(s): Block: Section: � Sq. Feet: Est. Value: Book: Page: Cost: 494,148.56 Total Fees: 12,420.69 Subdivision: SILVERADO Amount Paid: jZ �20, �O Date Paid: �-28-C Parcel Number: 05-26 21-0070-00300-0110 , CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES INC � Addr: 15550 LIGHTWAVE DR Address: 4600 W. CYPRESS ST STE 200 CLEARWATER, FL. 33760 TAMPA, FL 33607 I Phone: (727)479-1740 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 4,646 SQ FT ' APPLICATION FEES BUILDING FEE ,786.45 ELECTRICAL FEE 376.43 PLUMBING FEE 250.95 MECHANICAL FEE 175.67 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfd 1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 � � J I � � ��� � ��G _ .�, , � �-�� n--�.�-�����1�:���=��-c� ' Ins ections Re uired FOOTER 2ND ROUGH PLUMB MIS INSULATI N CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (e)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney I before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application.All work shall be pertormed in accordance ', with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTO S SIGNATURE P�RMIT OFFI I�' PER�IT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED ' PROTECT CARD FROM WEATHER � .� � , � e e �., ;,' PASCO COUNTY �_' BUILDIPIG CONSTRUCTION SERVICES y '. ., �_,�,�` '� 8731 Citizens Drive Date:11/14/2017 Syite 230 p1 •,' � , New Port Richey,FL 34654 , ' ' � ` �"'' 727-847-8127 *� �� 1 ^ 1 ��IV1�� �� Receipt#: 1719150 FEE DESCRIPTION ACCOUNT CODE l,�N� INVOICE# FEE AMOUNT PAID RECEIPT# UATE ImPact Fee Residential 5olid 24503100-329010 10.03 1299222 $10.03 $10.03 1719150 11/14/17 Waste.Single Family ZHILLS SOLID WASTE. TOTALS: $10.03 $10.03 Receipt# Paid Bv Check# CC Auth# Cash(er ID Workstation Receipt Date Amt Paid 1719150 Check 20299 294 BCCBISCAN02W 11/14/2017 $10.03 Total Payments: $10:03 Pavor Address Phone LENNAR HOMES 6502 PADEN WHEEL ST. � 8133632891 Comments• ZHILLS SOLID WASTE 6502 PADEN WHEEL 5T. 0526210070003000110 i P#18699 - �� - - - — ----- — - -- — r — - - 5 I � 1 ' 0289585G Lennar Homes,LLC . JPMorgan Chase eanlc N.A. STUB CHECK NO. 920299 � : 900000.10'10,114 1 of 1 DATE 11/02/17 /NYDICE !_'p,;t �' NUMBER DATE . PAYAIENTADYICE GROSS ��DISCOUNT NET ' 15225 15225710311.401435 102517 152257103I1401435 $10.03 � $0.00 510.03 � 1 1•� . - r.- � � 1 � ,� , � 1 J �� - � � � , � 1 � , �" ��� � �� � , � � �� � - � ( Pasco County BOCC 7530 Little Roa � 1971597 Port Richcy FL 33553-0000 $L 0.03 $0.00 $10.03 I � , �' � ; • � , �� � � MyReports/reportsl/PRODUCTION/PASCO/ReceiptPOS V4.rpi 11/14/2017 Page'1 of1 `i � 6502 Paden Wheel Street-Lennar Home-4646 sq ft o umn SQ. FEET PRICE MAIN OR LIVING: 4,646 $ 106.36 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 494,148.56 FEE SHEET $ 1,673.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,786.46 ELECTRICAL: $ 376.43 , PLUMBING: $ 250.95 I MECHANICAL: $ 175.67 SUB-TOTAL $ 2,589.50 TOTAL $ 2,589.50 i SEW ER: n/a � WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - n/a PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,142.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 N/A 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 12,420.69 r' � 6502 Paden Wheel o umn SQ. FEET PRICE UNDER ROOF: 4,646 $ 106.36 OTHER: - $ - VALUATION $ 494,148.56 FEE SHEET $ 1,673.00 ADDRESS $ 40.00 - DRIVEWAY $ 40.00 BUILDING: $ 1,786.46 ELECTRICAL: $ 376.43 PLUMBING: $ 250.95 MECHANICAL: $ 175.67 SUB-TOTAL $ 2,589.50 TOTAL $ 2,589.50 , SEW ER: WATE R: IRRIGATION: $ - f TOTAL: $ - WATER METER: IRRIGATION METER FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 ' TOTAL: $ 553.35 S U B-TOTAL $ 3,142.85 ' PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 12,420.69 . Q� p-_ , ',/��y - f1�lAi�6' : ��\/ ��^:i..�.. : � : . ��' _ '�s'J ,,r: City of Zephyrhills BUILDING PLAN REVIEW CONIMENTS Contractor/Homeowner: � � - - - - -- ---- ----- -- -- Date Received: — --------- - - ---- - - �/��� �--- -- 6 --- Site: �J��3� GtGt-C� �� Pernut Type: :3� � I �s�� c�c , i • Approved w/no comments:❑ Approved w/the below comments: � Denied w/the below comments: ❑ s�� s�� � This comment sheet shall be kept with the permit and/or plans. / � ,-- ��/- 7 �. Kalvin Switz —Plans Examiner Date Contractor d/or Homeowner _ (Requir d when comments are present) � � Illlllllllllllllllllllllllllllilllllllllllllllllllllllilllll � � 201711677]� � ' Rcpt:1881928 Rec: 10.00 DS: 0.00 IT: 0.00 � 07/25/2017 IC. M. , Dpty Clerk . PRULR S 0'NEIL,Ph D PRSCO CI.ERK & COMPTROLLE � 07/25/2017 Q�2:40pm 1 ofr�1 �y ' OR BK ����� . P� 3L�L � Permit No. ' Parcel ID No 05-26-21-0070-00300-0110 NOTICE OF COMMENCEMENT state of Florida cou�ty of Pasco � THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713, Florida Statutes, � � the following information is provided in this Notice of Commencement: 1. Description of Property� Legal SILVERADO RANCH SUBDIVISION PHASES 2.3,&4 PB 73 PG 59 BLOCK 03 LOT 11 � st�eetada�e5s. 6502 Paden Wheel Street Zephryhills FL 33541 � 2. � General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence 3 Owner Information: Lennar Homes, LLG � Name 4600 W Cypress St. Ste 200 Tampa FL. 33607 � Address City State Interest in Property� � Name of Fee Simple Titleholder• N�A (If other than owner) Address City State a contractor• Lennar Homes, LLC � Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address , City State Contractor's Telephone No.. 813.574.5700 5 Surety� :. N/A ' Name Address Cit� State � Amount of Bond: $ Telephone No. 6 Lender� N�A - Name • � � Address City State . Lender's Telephone No.. ' 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by � Section 713.13(1)(a).(7),Florida Statutes: Lennar Homes LLC � - . Name � 4600 W Cvpress St, Ste 200 Tampa FL, 33607 Address, City State ` Telephone Number of Designated Person: $�3 574 5700 - � 8. In addition to himself,the owner designates N/A of - to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner- 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT ` WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA �� COUNTY OF PINELLAS � Signature of Owner or Owner's Authorized Officer/DirectoNPartner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this �5 day of March 'd 0\1 ,by Steve Robert Smith as Vlce President (type of a e' ,e. .,o�cer, tee,attorney in fact)for Lennar Homes LLC (name of party n.beh of e instrument was executed). Personally Known�OR Produced Identification❑ - ,�Notary Si � Type of Identification Produced .� � Name(Print) Elissa Holleran Verification pursuant tb Section'92..525,�Florida Statutes. Uncler,penalties of perjury,I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and tielief: ' ' '�� i��.`' � �" ELI5511M.HOLLERAN Signature of Natural Person Signing Above C,�mmleslon�FF 8A5831 o` Ex�fres June 6,20Y0 wpdata/bcs/bcs form: ��'�f:�''�, 6unddThN7royFalnlMunncal00aB5-7D1p , � i � �' ��/mp s'�A'���F Fi c��inc� r�irpw�v nF�a�CO � o. ��'�� THIS IS TO CERTIFY ThfAT THE FORE�OING IS A �s�,. e'�� m e� TFtUE ANa�CORf2ECT COPY OF`f'HE DQCI iMENT � ��' ,�Y°� � � ON FILE�Qf�;OF�PU�L�IC��ECORD IN_THiS,QFFICE � _ w �:. - -�a W NESS MY ��' f HA�VD� a �����i� i.�s�w�� t�i , � 2 '�,.� � , �kr � PAU�S O'N�10�l�� C�� M rROLLER • C� � ,• � � ay ' e � � B DEP TY CLERK �������� , � � �= P�SCO G+�UNTY, �L�RID,��► r: � ` Permlt No. f�� Date Permitted _�� Builder NamelOwner Name ��/ttE,- �'���C- Control# County Parcef No. ��S=Z�F-�-'j-(}D 7p�QD31X1-15�l� SubDiv: C����'+� Address/Location i�d�- �Q�G�1'L Gcl�[Sc�.� �U Classificationfl'ype af Use �����t�L�/ �1�� TRANSPORTATiON IMPACT FEE Rate: Sq.Ft Unit: � Exempt �Yes � No How Determined � Impact Fee Amount $.��,�3�. Zone No. TAZ: SGHOOL IMPAGT FEE ,� Account {056) Single-Fami{y Detached House Amount $ T�(���� � � {057} Mobile Home {058) Ofher Restdentia! 123� Callecfion Fes Exempt [�Yas [] Na How Determined PARKS AND RHCREA710N PEE � Land Accaunt Land Credit Land Tota! Recreation Account Recreation Credit Recreation Tatal Zone TOTAL AMOt1NT $ `2�j���a Exempt [�Yes [� Na Now determined LlBRARY FEE Land Account Land Credif Land Tota! Facility Account Facility Credit Faci(ify Total Exempt ❑Yes [� No How Determined Tatai Amount �-�'" RESOURCE FEE ERU i"OTAL AMOUNT � Prepared 8y � Checked By NO CEFt7lFiCATE OF OCCUPANCY WiLL BE ISSUED OR FINAL(NSPEGTION PEi2FORMED UNTIL THE'ftlTAL AMOIlNTS LISTED HAVE BEEN PA{D ANQ RECEIP7ED FOR BY A CENTRAL PERMITTING O�FICE OF PASGt?GOUNTY I Acknowiedgement below does not impiy acceptance of concurrenae,but slmply recalpt of a copy of this form,piacing � the bulld{ng permit owner on notfca of this assessment and the cond(tlons of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY .�.���,�,.�r� - ___. Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. 9. No electric, plumbing,mechanical, or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. All 2008 N.E.C. Codes will be enforced. 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 22. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 5�'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008) I � � 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permittin 813 363 __ 2891 —I—I�r�—r— I—IT Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700 Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name N�A Owner Phone Number Fee Simple Titleholder Address N/A JOBADDRESS 6502 Paden Wheel Street LOT# 0110 SUBDIVISION Silverado Ranch Subdivision Ph 2,3,&4 pqRCEL ID# 05-26-21-0070-00300-0110 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED II./ II NEW CONSTR e ADD/ALT � SIGN � � DEMOLISH � INSTALL REPAIR PROPOSED USE � SFR 0 COMM � OTHER TYPE OFCONSTRUCTION � BLOCK 0 FRAME 0 STEEL � DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE �R SF 4520 SQ FOOTAGE 3711 J' � HEIGHT 2 StOry rfTTrTIT��rTT�TI"I'T'T PTr ✓ BUILDING $ VALUATION OF TOTAL CONSTRUCTION � SO '�/ 'ELECTRICAL $ � PROGRESSENERGY� 0 W.R.E.0 ' � ` AMP SERVICE �PLUMBING $ �MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION OGAS � ROOFING Q SPECIALTY � OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA �YES �O �L�r u ��-�--�N-�-�--��--��-a-�--�-+��-E-a-�--F-E-�s-�--�E-�--�-F-t-��--�F-�-��--�--E-E-�-N�-E-E-E-�-+�r--�r--�-�-t-a-�-�-�-�--i-�� BUILDER COMPANY Lennar Homes,LLC SIGNATURE /'� REGISTERED Y/ N FEE CURREN Y/N Address 4600 W.C ress St.Ste.200,Tampa,FL 33607 License# CGC1518166 ELECTRICIAN COMPANY Edmonson Electric, Inc. SIGNATURE REGISTERED Y/ N FEE CURREN Y/N . Address 1034 Skipper oad, Tampa, FL 33613 License# EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 530 , Bayonet, FL 34674-5308 �icense# CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P O. Box 5308, Bayonet, FL 34674-5308 �icense# CAC058062 OTHER COMPANY SIGNATURE � REGISTERED Y/ N FEE CURREN Y/N Address 4211 Shoal Line Ivd, Spring Hill, FL 34607 �icense# CCC057991 � � � � � � t � ii � � ii � � � � tr � � � � iiiiii � � � � iii � � � iii � � i � � � � ii � � i � � � iii � � � � � i RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities 8�1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. � ..4�I..�C�-G..-..-{..1-1..��1..��1..�1..��l�-.1�1--f-�-��1..1..1-I..�I.��I..I..L-1..�1..{-1-{..��1-.��f..�l..{-1-f..4.�-L..1-{-1..1-� Directions: Fill out application completely � Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is requiFed. (A/C upgrades over$7500) ' "" Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(PIoUSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW ' , , NOTICE OF DEED RESTRIC710NS� The undersigned understands that this permit may be subject to"deed" restrictions" which may be mare restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed res#rictions. UNL.ICENSED CONTFtACTORS AND CONTRACTOR RESPOMSIBILITIES: If the owner has hired a cantractor or cantracfors ta undertaEce work, they may be required to be Eicensed in accordance with state and local regu(ations. if the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor vialation under state law. If the owner or intended cdntractor are uncertain as to what licensing requirements may apply for the intended wark, they are advised to contact the Pasco Counfy Bttilding Inspection Divisian—�icertsing Section at 72T-847- 8009. Furthermore, if the owner has hired a contractar or cantractors, he is advised to have the contractor(s) sign portions of the "contractor B(ock" of this app(ication for which they will be responsibEe. If yau, as the owner sign as the con#ractor, that may be an indication that he is nat proper(y licensed and is not entitied to permitting privileges in Pasco ' County. � TRANSPC}RTATItJN IMPACTlUT1l.ITIES IMPACT AND RES�URCE REC�VERY FEES: The undersigned understancfs that Transportation Impact Fees and Recourse Recovery Fees may apply to the canstruction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, wi(I be identified at the time of permitting It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release If the praject daes nat involve a certificate of occupancy ar final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with appficabfe Pasco Coitnty ordinances. CCINSTRt3CTtON LIEN LAW(Chapter 713, Florida Sta#utes, as amended): If valuation of work is$2,500 00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction L.ien Law—Homeowner's Protection Guide" prepared by the Florida Department af Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a capy of the above described document and promise in good faith to deliver it to the"owner"prior to eommencement. CONTRACTOR'S/OV1/NER'S AFFiDAVIT- I certify that all �he information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do warlc and installation as indicated. 1 certify that no wark ar installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdictian. l aEso certify that I understand that the regu(ations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actians I must take to be in compliance. Such agencies include but are not limited to - Qepartment of Environmental Pratection-Cypress Bayheads, Wetland Areas and �nvironmentally Sensitive Lands,Water/Wastewater Treatment. ` - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercaurses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Nealth & Rehabilitative ServiceslErtvironmental HealtFt Unit-UVells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviatian Autharity-Runways. I understand that the follawing restrictions apply to the use of fill: - lJse of fill is not afiowed in Flood Zone"V"unless expressly permitted. - If the fil( material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a prafessional engineer licensed by the S#ate of Florida. - If the fill material is to be used in Flood Zane "A" in cannectian with a permitted building using stem wall canstruction, 1 cerEify that filE wi!! be used only to fill the area within the stem wail. - If fill maferial is ta be used in any area, I certify that use of such fili will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the canditians of the building permif issued under the attached permit application, far lots less than one {1} acre which are elevated by fill, an engineered drainage plan is required. If I am the AGE(d7'FOR THE QWNER, ! promise in good faith to inform the owner of the permitting conditions set forth in fhis afFidavit prior to commencing consfruction. I understand thaf a separa#e permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be consfrued to be a license fo praceed with the work and not as authority ta violate, cancel, alter, ar set aside any provisions af the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations af any codes. Every permit issued shali become invalid uniess the wark aufhorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended ar abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building �fficial for a period not to exceed ninefy (90} days and will demonstrate justifiable cause for the extensian. If work ceases for ninety(90) consecutive days, the job is considered abandoned WARNING TO OWNER. Y{)UR FAILURE TO RECORD A NOTICE OF CC)MMENCEMENT MAY RESULT IN YOUR , PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU IN7END TO OBTAIN FINANCING,CONSULT 1NlTN YOUR LENDER OR AN ATTC>RNEY BEFORE RECORDENG YOUR NOTICE OF CQMMENCEMENT. FLORIDA JURAT(F.S.117.03) ! OWNER 4i2 AGENT CQNTRACT4R Subscribed and sworn to(or affirmed}befor me this Subscribed and sworn to(or affir ed) efore me this � i a-ivi ay-i� py paul Sweene 15-May-17 py Paul Sweene Who islare personally known to me or UVho istare ersona!! known to m or as ide ification. es identification. �� --- _ ^-•-------_._ Notary Public Notary Public � Commission No. �F98537 Commission Rto. �'F98537 � Elissa M.EIolleran Elissa M.Holleran R1ame of Nofarv tvAed,printed or stamped Name of Notary typed,printed ar stamped ,r.� .� ��(fl�h�.�1Q�� `"`��.��'' ��I�uA�,PI�?1��1V' -- � �M �rr�r���n�M�P���gT ; ��Can�,�€�stMP�0E�9? �rk'i���.���,�t�� ' EaSR#�,dUt��,�'���,Q �'� Csa�l+�I3triT.eayl�tMlf��!l�CaM�1klO ��. .� �ii+rl`�ra��yl�l�ts+en�►�t��ll��@li SKETCH ONLY TWp_ 26 S, RNG. 2� E. PLOT PLRIV SEC. 05 NOT A BOUNDARY SURVEY LOT 11, BLOCK 3 � BEARING BASIS: ` -� SILVERADO RANCH SUBDIVISION ` - PHASES 2, 3 8C 4- NORTH BOUNDARY OF SE� OF 05-26-21 BEING N 89'25'O7" E ' PASCO COUNTY, FLORIDA. �T THIS SURVEY IS SUBJECT TO ANY FACTS THAT j� MAY BE DISCLOSED BY A FULL AND ACCURATE T1TLE SEARCH. ALSO SUBJECT TO SETBACKS, PRELIId11NARY`DRAWII�iG: EASEMENTS AND RESTRICTIONS OF RECORD. THIS PLAN IS FOR PERMITIING PURPOSES o ONLY, NOT FOR CONSTRUCTION. VERIFY � UNDERGROUND FOOTER, STEM WALL, AND ALL DIMENSIONS BEFORE ANY CONSTRUC110N. II UNDERGROUND U1ILITIES ARE NOT LOCATED OR SHOWN. LEGEIdD: w DO NOT SCALE THIS PRINT. DIMENSIONS AND f-�= PROPOSED DRAINAGE FLOW J NOTES TAKE PREFERENCE. (00.00) = PROPOSED GRADE c¢i E-00.00 = EXISIING GRADE � DESCRIPTION NOT CONTAINING PLAT BOOK AND PAGE INDICATES THAT PLAT IS IN PRELIMINARY STAGE AND IS SUBJECT TO NOTES: CHANGE AND/OR REVISION. LOT GRADING TYPE = A PROPOSED PAD ELEVATION = 110.1� CERTAIN DATA SHOWN HEREON BASED ON FRONT SET BACK = 2a' ENGINEERING PLANS PROVIDED BY CLIENT. SI�E SET BACK = 7.5' STRUCTURE TIES SHOWN HEREON DENOTES REAR SEIBACK = 15' \ � MEASUREMENT FROM FORM BOARDS/FOUNDAiION LOT 2 TO PROPERTY LINE. \ � BLOCK 3 oo * = 10' UTILITY EASEMENT ✓ _ S: 7g0S9�2�� E 6p �d� ON LOT AREA CALCULATIONS 53� `o°j' LOT = 9853.88 Sq, F'7', � : . - - LIVING AREA = 1713 Sp, F7'. .i� •M EN1RY 35 _SQ. Fj. �`� =�v GARAGE 606 _gQ, �, �' o^,, COVERED LANAI 294 SQ. �. - N= PA110 = N,A--SQ. FT. 'o0 420 ' CONC. ORIVE = 1132 gq. F7', �o.z,,;.' n � A/C & CONC PAD = 24 SQ. �. PRIVATE SIDEWA�It = 3 SQ. FT. � � ��•38� IMPERVIOUS = 39 _y, /�' S�5'34'27"E = 3807 $Q. FT. LOT 10 ^ v 5o'_p� SOD = 6047 SQ. FT. BLOCK 3 ^ Q PR�P�SED p�AN OFF.LOT AF�EA CALCULATIONS <c/ E� �11 00 GqRq��A' � RIGHT OF WAY = 1951.68 gq, �, , � W LOT »EFr DRIVE APRON = 233 _gq, F'�', PUBLIC SIDEWALK = 531 gQ, F"(', � �� BLOC/� 3 SOD = 1188 SQ. �'. � N�� ^ O� � c�, LOT 12 Z t7.s2' " BLOCK 3 TOTALS _ _ • c0 AREA = 11805.56 gq, F'7', ' DRIVEWAY = 1365 _gQ, �, � . ' `r SIOEWALK = 534 SQ. FT. .�: :;,�;,;. 'ry � � SOD = 7235 SQ. FT. � . �� . .. � - .?3.2g, �... . , � \ /' ���M �' ' � \•f-' • 'M �;;.� 'm �a 66�823 . '� , •. '� � ✓ 33 � :p . :' : . . o � <r� � `N � �. �:T6 pp•_'� . � _�. �p .... * � • �66, l• . .. : •C's3 • . ..- , `o — .�:C'154.- y -og \ �o � � . , � ¢ \ _ . ,. .. `� c� `�' pCP�� oi � v �m J o --' ��r " P�DE HWN EEL STREET \ �o (R/W VARIES) (TRqCT L) � 3 v � DESCRIPT'IO�i: Y LOT 1 1, BLOCK 3, MAP OR PLAT ENTITLED "SILVERADO PROPOs�'IED: m RANCH SUBDIVISION PHASES 2, 3 & 4", AS RECORDED IN LOWEST FLOOR ELEVATIONS: � PLAT BOOK 73, PAGES 059 THROUGH 065, OF THE PUBLIC LIVING AREA: 110.80' ;' RECORDS OF PASCO COUNTY, FLORIDA. GARAGE AREA: N ELEVATIONS REFERENCED TO _ a CURVE RADIUS ARC CHORD BEARINC DELTA NORTH AMERICAN VERTICAL = cis3 2n.00' �os.ot' �oa.ss' N 7931'sz^ w zi•as'is° DATUM OF 1988. MEAN SEA Z ctsa v�.ao' �s.si� 73.69' s arsa'os'• w is7��is" LEVEL= 00.00 FT. � i � APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL N0. 120230 0455 D EFFECTIVE DATE: 09/30/1992 0 � LEGEND: . > (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, r�= CENTERLINE, A/C= 'AIR CONDI110NER, B/C= BACK OF CURB, C/S= � CONCRETE SLAB, CH= CHORD,'CH6= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, / F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FlP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL 8t DISK, FPP= FOUND PINCHED � PIPE, LFE= LOWEST FLOOR ELEVA770N, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, P6= PLAT BOOK, PCP= PERtv1ANENT CONTROL POINT, PRM= PERMANENT a REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, 1BM= TEMPORARY BENCHMARK, � � U P= UTILITY POLE, W F= WOOD FENCE, R = RADIAL � JOHN R.BEACH&ASSOCIAT�S�IH�IC. Drawn By. SMS Square Feet: 9853.88 t LENNAR HOMES w + SURVEYORS AND MAPPERS - > e 911 WEST ST. PETERSBURG DRIVE Checked By. v� ONE OLDSMAR, FLORIDA 34677 JRB � WAY (813) 854-1276 FAX (813) 855-8370 Scale: � N 1"=30' c � o � •; NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 6 8 17 ACS 'v THE ORIGINAL RAISED SEAL OF A FLORIDA JOHN BEACH DATE � LICENSED SURVEYOR AND MAPPER FLORIDA G. LAND SURVEYOR No. 2984 LB#4493 / Revisions: � �u= 1 [h � l�' ,r '�' , ' '\V" � � � , ,- � - � � - ^v • , � �� - � � •,�• ', - � �+ ' 1 6� � ." ', ) _ � ,�-. _ _ . , � � . � j a•Y �F=1 Q9.60 . � i �'1�'' _5 FF=1 Q9.90 FF=1.09.70 �� �, ' .� �`� + � �- - LDT 12 `: � . �`'� �-, LOT 2 LOT 1 T�� �_ .. S� S � PAD=108.9 l � -� � � ,,p�p (�� f � j - _ �,, � . ' `� , O� " V�--� � �1 � PAD=109.0 � „rr,� 'I 1 � � T` _ U I TYPE� � ,p�• � °v� `�A ��• ti1�J `fi TYPE A �`� � i , • �r '�e. � •:�. � • �' •, � FF=t'I,�T_� - - �� ' � . i ' � � 1;��.1,� e• � �` .��. � � LOT 9 � , �. � � ' � l 6" ,r- `�' `- � ,s- � � PAD=5 09.6 ' � 5� � ��` �,.' � �' n- r � �_ � � . .�111.�' � �` TYPE A , '` �� ( � ,. �` . ,r �r m 9' n„a , � •�� � 110. K � . f'=µ\,c-e• �` � ! FF=1�9.50 ;,� ,�� i -} • �� \ r �' " � ` � 1� bs � ��• ,i. m' �a• LO��JII �1 � " � ! ,k e- »� �� , � - P�� O8-�,iz- �1�� J �� y i 0 g. b`� C ��� � �0 � � y� ' \� �` R 1' ' 6• _ �ls- �:� .,\ PE B '' � `� �1 �C =11� � ��i , ODc ��`� ,��1 't� .ti �7 , Q� s , �� � �or��� g- o- °� ��� � ° � o��� 'R�¢'iT�����' �6" 6'6 � Y ' �\ PAD=110.0 �'� :� =�1'^ 1_ �-J� '1 � 6- . TYPE A o' FF=1 rt 0.30 � �- o . •. ��c , �� � � s'` 'a4 LDT 13 ` e-�`��"�� �v • � _---, : < FF=110.80 PAD=104.6 � 'L �_ o,�- ���\ __20 r--�e. � FF-�pg�;c � - O. \�. LOT 11 FLaT10.20 TYPE A �1 e� Q � - 6 � ,� �. PAD=1 1�.1 PA�109.9 1 '� 1 � b ; y _ � LO����. �. � 0 1 � TYPE A TYPE A / '�a \ , � _ _ PAD-T T �� c� c,��`\` �.,j b�-� TcFp��-__ i o� 6 „b g�- h � '�L` �o � O�' ,j pC 6 �� �'1 '1� �` `L_- � ,�o� b ,ti,.P�� ���, ' i, �g �� --- 'r v --1� 1� �� �.� ,.�0 `� g' � � �'� Q_. �� a• na i � ' }� __r-^v�" 5 � 4 � , , � „ +� � �^� ' � � ' �'r� ��V �"� _�T6�33 �1� 1 �° � � - f s -_ _-` - _ � -' '�� ^p `7 �z{�p��`�w�(1 - 2D" DRAlNAGE EASEMENT � p� � � OQ t ` "FAScMENT '��l u^��\ -�'----�----- �t� � �.� n� 10' lli7 1 o_ Q\` 6' r � (` y ' -`�� s..-- C�,�\Z p (�:y , L, ..�1 n�'i'� v .: n _ �\ �'� �,,ti _qq, �� '^u9' " 9'�("�� �� ^ F��OH.80 � g �'t� _"� ,� ' �'v � � \ „r,/. �• ����� �T 9 � � � 1 ��1 F1 "• - �---�'-� , r� ' +� rl ' O G B- i os.i g � � ��., � ,� �,, a� � '��. tR� � �Pf B �V ' ' -_ ----'� `, � � � ' � 1O '� `� ` Pi G �F �'1 y I .,�ly � �, a �1�=<' - ' � , ' , �l . •��S� � Q __------ P - . ~,� _- t0' UTTu7Y _ EhrE'pr-L_� - - ' ' 1� �'q"- 7�(58.8 -- FF=1�9.90 �= ` s Ff"=109.QD r� u-, r iZ �� �QT(_� ���. ' . LOT 1 1 .� a�' � �+,<_ PAL�,�08.3 FF=1�9_20 , FF-110.2 �- FF=110.16 P�yPE�B Z �� ' , �:°� � ,�• 3• TYPE�� . , L(�T 7 � �dT � FF=110.5a ti FF=11�.50 FF=710_3�.- '' - �OT 2 � 50 - �A1„�- PA�-108.5 �' • LQT 5 LOT 4 LOT_-3"� P�=109.d �1 -�"' .s c 'V � •�PAD=A.�8.5 PAI2= 18 TYPE B c, OC7• " 3"� ��� � � �STYPE B ��B � PAD=t Q9.8 PAD=109.6 `5� ,-� .��r• , � �., rF��� TYPE BJ�I TYPE B CC��J '� , �T�O � c \ ro 6 �.����'S �3. ; 1,���� 1 � � _ 1 _ i07.$ ` �t�- � \ r� a- ���.,r :�O ' - ------ -- ��"` _ 7 l g -� e-�� I T �� _,� �� 4 .� � , •� '"0< . �;;'• - - ,� r � � `, ' ��`1 ����. �• ''• a,8• �p T. �.-'" • C" l�b: -u, �r • _,'�^ _1 , "' 'v� 5 18'(87. � � � . � �1S Y" `V \ `'�� � d • O -�^�' •�� � I ,�'� �A ` '.\��.�n•�� ���` `'aQ'• � ` ' ' ` ' _ ' ' ' ' ' ' T ' {a'_ _'- � � '/'' ' J�v � � WETLAND ;��. ��.�� _ � , . - � CONSERVATION �� �� ���. Y�, _. _ � ---- ,�Q�. � ` � �e� ��,r ,. . � � �-g-a-�-�-�.� +.\ �� �� '`e` �" °�� • �"" r / ��O'a��r�i�� � _ AREA P �. „- _ ,,. P T -�,.�,�- �� _, - ��} . { Y T, a• � (1 .22 AC. _ __. -- � e`�6'��\`� ��` �. --- O'`,� �� T �- "". _o-�n 6'� P16P����-��a�� '-•���'��Jr'S�-� � •'\ �\ ` �[ • '6- 9"6" Y� 4 Y�� .T �••'�6- qOY •Y . ]OOYRDHW=104.0 -_ __ -----_. _ . COf1fTROL SFRUCTUR�C�^em s. � ��0 • ��• • =� J �T o.��%��� � , ' - '.-- ._ ',� \ v ` �ar ' � , 9 ' /'"7 T � - " Ci ���� �� � --�O�S, �� (��lif �o` �t' dL' . _ . . . - . • - - � a- - e- - -� - - -- ---------- -- - - � - -- - _.. _._..,__.�_.. -.._ .------------ HO SF RUBBLF � .�2°� _��, - �--�°�•-_---- -ti� . . . � FORM R405-2014 � � FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION - Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 3711A sf ADS Builder Name: LENNAR HOMES , street: 6502 Paden Wheel Street Permic o�ir.�: City of Zephyrhills - City,State,Zip: ,FL, Permit Number ��j�q� Owner LENNAR HOMES Jurisdiction: 611600 Design Location: FL,Tampa County• Pasco(Florida Climate Zone 2) 1 New construction or existing New(From Plans) 9. Wall Types(3424.9 sqft.) Insulation Area 2. Single family or multiple family , Single-family a.Frame-Wood,Exterior R=11.0 1738.70 ftz b.Concrete Block-Int Insul,Exterior R=4.1 1487.10 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 199.11 ft2 4 Number of Bedrooms 4 d.N/A R= ft' -- 5. Is this a worst case? Yes 10.Ceiling Types (2134.0 sqft.) Insulation Area 2 a.Under Attic(Vented) R=30.0 2002.00 ft 6. Conditioned floor area above grade(ftZ) 3720 b.Knee Wall(Vented) R=30.0 132.00 ft' Conditioned floor area below grade(ftZ) 0 c.N/A R= ft� 11 Ducts R ft� 7. Windows(368.0 sqft.) Description Area a.Sup: 1st Floor,Ret: 1st Floor,AH:ist Floor 6 343.6 a. U-Factor Dbl,U=0.54 138.00 ft' b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 400.4 SHGC: SHGC=0.31 b. U-Factor' Dbl,U=0.56 123.36 ft' 12.Cooling systems kBtu/hr E�ciency SHGC: SHGC=0.28 a.Central Unit 252 SEER:16.00 b.Central Unit 25.2 SEER:16.00 c. U-Factor Dbl,U=0.56 106.67 ft' SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor• N/A ft2 a.Electric Heat Pump 21.8 HSPF:8.50 SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 Area Weighted Average Overhang Depth: 3.098 ft. , Area Weighted Average SHGC: 0.303 14 Hot water systems a.Electric , Cap:40 gallons 8. Floor Types (3720.0 sqft.) Insulation Area EF 0.950 a.Floor Over Other Space R=0.0 1725.00 ft' b. Conservation features b.Slab-On-Grade Edge Insulation R=0.0 1718.00 ft' None c.other(see details) R= 277.00 ft' 15.Credits _ Pstat Glass/Floor Area: 0.099 Total Proposed Modified Loads. 101.89 pASS Total Baseline Loads: 101.96 I hereby certify that the plans and specifications covered by Review of the plans and d�'C�:$T.��.� . this calculation are in compliance with the Florida Energy specifications covered by this � ir � ' __�pY,t, Code. calculation indicates compliance ���r„°o�?� '=;,..,�. �. /,,� /" with the Florida Energy Code. y"-���` "1 � • t`�'. I1F1C4'" �'+'�:,=s•��s,��tA-�� . PREPARED BY. �aVe �Wl�'I�YG Before construction is completed w �' " �' � -.�`l�i-_...... �: . � DATE: this building will be inspected for try ��::�� . compliance with Section 553.908 • , � � � � I hereb certi that this buildin as desi ned, is i com liance Florida Statutes. e�� __ �. Y fY 9, 9 P ��5. with the Florida Energy Code. �'�I){�y�'�` OWNER/AGENT: BUILDING QFFICIAL. DATE: DATE: /� " - Compliance requires certificafion by t air handler unit manufacturer that the air handler enclosure qualifies as ce�tified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 6/13/2017 9:57 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 � 7 � FORM R405-2014 - FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Fiarida Department of Business and Prafessional Regulation - Residential Perfarmance Method Project Name: 3711A sf ADS Buiider Name: LENNAR HOMES street: 6502 Paden Wheel Street Perm�t ot�ce: City of Zephyrhills City,State,Zip: ,Fl., Permif Number� Owner� LENNAR HOMES Jurisdiction: 611600 _ Design�ocation: FL,Tampa County_. Pasco(Florida Climate Zone 2) 1 New canstruction or existing New(From Plans) 9. Wall Types(3424.9 sqft.) Insulation Area 2. Single family or multiple family Single-fami{y a.Frame-Wood,Exterior R=11.0 1738.74 ft2 b.Concrete Black-Int Insul,E�;kerior R=4.1 1487 10 ft' 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 199.11 ft2 4. Number of 8edrooms A �•�lA y�= {{_ 5. Is this a worst case? Yes 10.Ceiling Types (2134.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.� 2002.00 ftZ 6. Conditioned floor area above grade(ff� 3?20 b.Knea Wall(Vented} R=3Q.0 132.4{i ft' Condikioned floor area below grade(ft2) 0 c.N/A R= ft2 11 Ducts R ft2 7. Winc3ows�368.0 sqft.} Descripfion Area a.Sup.1st Fioar,Ret:1st Floor,AH:1st Flaor 6 343.6 a. U-Factor• Dbl,U=0.54 138.00 ft' b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 400.4 SHGC: SHGG=0.31 b. U-Factor� Dbi,U=d.56 123.36 ft2 12.Cooling systems kBtulhr Efftciency SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 b.Central Unit 25.2 SEER:16.00 c. U-Factor Dbl,U=4.56 1 d6.67 ftZ SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor� N/A ft2 a.Electric Heat Pump 21.8 HSPF:8.50 SHGC: b.Electric Heat Pump 21.8 HSPF;8.50 Area Weighted Average Overhang Depth: 3.098 ft. Area Weighted Average SHGC: �.303 14 Hot water systems 8, Floor Types (3720.0 sqft.) Insulation Area a.Electric Cap:4Q galtons EF 0.950 a.Floor Over Other Space R=0.0 1725.00 ft2 b. Gonservation features b.SIab-On-Grade Edge Insulation R=OA i718.0a ft2 None c.other(see details) R= 277.00 ftz 15.Credits Pstat Total Praposed Modified Loads: 't01 89 � A�� Glass/Floor Area: 0.099 h 7ota!Baseline Loads: 101.96 t !hereby certify that the plans and specifications cavered by Review of the plans and �'£��T,�q�,� _ C} .- �..; � this calcuiafion are in compliance with the Flarida Energy specifications coveted by this "w�f�* � ,��; C7�,, Gode. calculation indicates compliance r,,�'�rs��: :._,.-,4�. � with the Florida Energy Code. � °n„��r� �'� � (,,j /� �^� ��rarr:._*�:.;:;�, �a 1S �} . ����i �WI��iYG ,� � ' :. ��;' �,., �. PREPARED BY: Before construction is campleted w.. ; �- DATE: this building will be inspacted for t�g. """I'����T:"" :y�, �, compliance witF�Section 553.g08 ,� � � I hereb certi that this buildin as desi nad, is in com liance Florida Statutes. : Y fY 9, 9 P ���, .���' with the Florida Energy Coda. �� OZ�y�r�"� OWNER/AGENT. BUILDING O FICIAL. DATE: DATE: " ' - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory�eaied in accordance with R403.2.2.1. -Compliance requires an.Air Barrier and Insulatian Inspection Checklist in accordance with R402.4.1.1 and an envelape leakage test report in accardance with R402.4.9.2. 6/13/2017 9:57 AM EnergyGaugeOO USA-FlaRes2014 Section R405.4.1 Cornpiiant Software Page 1 of 5 FORM R445-2014 FLORIDA ENERGY EFFICIENCY COpE FOR BUILDING CdaNSTRUCTp(JN Floricia Department of Business and Professional Reguiation - Residential Perfarmance Method Project Name: 3711A sf ADS - Builder Name: LENNAR HOMES ' street: 6502 Paden Wheel Street ` perm�t o�ice: City of Zephyrhills City,State,Zip: ,FL, Permit Number Owner LENNAR HOMES Jurisdiction: 611600 Design l.ocation: FL„Tampa County� Pasco{Florida Climate Zane 2} 1. New canstruction or existing New(From Plans) 9. Wall Types(3424.9 sqft.) Insulation Area 2. Single family ar mulfiple family Singie-fami3y a.Frame-Wood,Exferior F2=11,0 1738,70 ft= b.Concrete Block-Int Insul,EMerior R=4.1 1487 10 ftZ 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.Q '!89.11 ftz 4 Number of 8edraarns 4 �•�1�'` R= ft' 5. Is this a worst case? 10.Ceiling Types (2134.0 sqft.) Insulation Area Yes a.Under Attic(Vented) R=30.0 2Q02.00 ft2 6. Conditioned floor area above gcade(ftz} 3720 , b.Knee Wa![(Vented} R=30A S 32.00 ffz Conditioned floor area below grade(fta) 0 c.N/A R= ftZ 11 Ducts R ft' 7 Windows{368.b sqR.) Descripfion Area a.Sup:1st Floar,Re#:1st F3oor,AH:tst Floor 6 343.6 a. U-Factor• Dbl,U=0.54 138.00 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 400.4 SNGG: SHGC-4.31 b. U-Factor Dbl,U=0.56 123.36 ft2 12.Caoling systems kBtuthr EfFciency SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 b.Ce�tral Unit 25.2 SEER:16.00 c. U-Factor Dbl,U=0_56 1QB.&7 ftz SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor N/A ft2 a.Electric Heat Pump 21.8 HSPF:8.50 StiGC: b.Eiectric Heat Pump 21.8 H8PF:8.50 Area Weighted Average Overhang Depth: 3.098 ft. , Area Weighted Average SHGC' a.3Q3 14 Hot water systems 8. Floor Types (3720.0 sqft.) Insulation Area a.Electric Cap.40 gallons EF 0.950 a.Floor Over Oiher Space R=0.0 1725.00 ftz ta, Conservation features b.Sta6-On-Grade Edge insulatian R=4.0 1718.00 ff2 None c.other(see details) R= 277.00 ft2 15.Credits Pstat Glass/Floor Area. 0,099 �otal Proposed Modifred Loads. 101 89 pASS Tota! Baseline Loads. 1(11.96 i hereby certify fhat the plans and specificatians covered by Review of the plans and r��T�?. this caicuiafion are in compiiance with the Florida Energy specificafians covered by this �+� ""`_�,�Q. Gode. calculation indicates compliance ��e,,��J''• ::=,��*��.� with the Flor'sda Ener Gode. �' rr��"r=���:.�'�x'''��»'; � 1,, 9Y � tr ,., .;;...srt,�;t,,,�ti 4 PREPARED BY' ��V�% �����'t Befare construction is completed �.� • " " � DATE: this building will be inspected for �. "'"i���`E� ' ;t, cornpliance with Sectian 553.908 * '.'^�-��- '� �.. ` I hereby certify that this building,as designed, is in compliance Flarida Statutes. :t�,,�( . " ���. with the Flarida Energy Code. Q.�"�`� CIWNER/AGENT. BUILDING OFF,CIAL. �'" r DATE: DATE: - Compliance requires certiftcation by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealeci in accardance with R443.2.2.1. �-Compliance cequires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and.an envelape leakage test raport in accordance with R402.4.1.2. 6/13/2017 9:5?AM EnergyGauget�USA-FlaRes2014 Section R405,Q 1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: 3711A sf AD8 Bedrooms: 4 Address Type: Sfreet Address Building Type: User Conditioned Area: 3720 Lot# Owner� LENNAR HOMES 7otal Stories: 2 Block/SubDivisian: #of Units: 1 Warst Case: Yes PlatBoak: Builder Name: LENNAR HQMES ftotate Angle: 225 Street: Permit Office, Gross Ventilation: No County� Pesco Jurisdiction: Whole House Fan: No City,State,Zip: Family Type. Single-family FL, NewlExisting: hlew{Fram Plans} Comment: CLIMATE j IECC Design Temp tnt Design Temp Heating Desigrs Daily Temp V Design Loca#ion TMY Site Zone 97.5% 2.5% Winter 5ummer Degree Days Moisture Range FL,Tampa FL TAMPA_tN3ERNATt 2 39 91 74 75 645.5 54 Medium BLOCKS Number Name Area Volume S Blockl 1718 159'T7 4 2 Block2 2002 16016 SPACES Number Name Area Volume Kitchen Occupants Bedroams Infi11D �inished Caoled }ieatad 1 1 st Floar 171 S 15977.4 Yes 0 0 1 Yes Yes Yes 2 2nd Fioor 2002 16d16 No 5 4 1 Yes Yes Yes F�OORS # Floor Type Space Perimeter Perimeter R-Value Area :loist R-Value Tile Wood Carpet 4 1 Floar over Garage 2rrd Ftaor __� ____ 277 ft2 11 0 0 1 2 Slab-On-Grade Edge Insulatio 1 st Floor 182.2 ft 0 1718 ft' �__ I1.3 0 Q.7 3 Floor Over Other Space 2nd Floor ____ __— 1725 ftZ 0 0.2 0 0.8 ROOF - t Raof Gable Roof So}ar SA Emitt Emitt Deck Pitch \� # Type Materials Area Area Colar Absor Tested Tested Insul. (deg) 1 Hip Composition shingles 2239 ftZ 0 ft2 Medium 0.85 No 0.9 Na 0 26.6 ATTIC V # Type Ventilatian Vent Ratio{1 in) Area RBS SRCC 1 Full attic Vented 300 2002 ft' N N 6/13/2017 9:57 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 30 Blown 2002 ft2 �.1 Wood I 2 Knee Wall(Vented) 2nd Floor , 30 Batt 132 ft2 0.11 Wood WALLS I Adjacent SPa� Cavity Width Height 5heathing Framing Solar Below _ 1 N=>SW Exterior Concrete Block-Int Insul 1 st Floor 4 1 21 2 9 4 197.6 ftZ 0 0 0.6 0 �i 2 S=>NE Exterior Concrete Block-Int Insul 1 st Floor 4 1 50 0 9 4 466.7 ft2 0 0 0.6 0 3 E=>NW Exterior Concrete Block-Int Insui 1 st Floor 4.1 40 4 9 4 376.4 ft2 0 0 0.6 0 4 W=>SE Exterior Concrete Block-Int Insul 1 st Floor 4 1 40 4 9 4 376.4 ftz 0 0.6 0 ! _ 5 N=>SW Garage Frame-Wood 1st Floor 11 21 4 9 4 199.1 ft2 0.23 0.01 0 I 6 N=>SW Exterior Frame-Wood 2nd Floor 11 50 8 400.0 ft2 0.23 0.6 0 7 S=>NE Exterior Frame-Wood 2nd Floor 11 50 8 400.0 ftZ 0.23 0.6 0 8 E=>NW Exterior Frame-Wood 2nd Floor 11 58 8 8 469.3 ftZ 0.23 0.6 0 9 W=>SE Exterior Frame-Wood 2nd Fioor 11 58 8 8 469.3 ftZ 0.23 0.6 0 10 N=>SW Exterior Concrete Block-Int Insul 1st Floor 4 0999 7 6 9 4 70.0 ftz 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>SW Insulated 1st Floor None .2 3 6 8 20 ft2 2 N=>SW Wood 1st Floor None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation(_>)chan ed to Worst Case. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>SW 1 Metal Low-E Double Yes 0.56 0.28 16.0 ft' 1 ft 0 in 10 ft 2 in Drapes/blinds Exterior 5 2 N=>SW 1 Metal Low-E Double Yes 0.56 0.28 23.0 ft' 1 ft 0 in 10 ft 2 in Drapeslblinds Exterior 5 3 S=>NE 2 Metal Low-E Double Yes 0.56 0.32 106.7 ft� 7 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 4 S=>NE 2 Metal Low-E Double Yes 0.54 0.31 22.0 ft2 7 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 5 E=>NW 3 Metal Low-E Double Yes 0.54 0.31 23.0 ft� 1 ft 0 in 10 ft 2 in Drapes/blinds Exterior 5 6 W=>SE 4 Metal Low-E Double Yes 0.54 0.31 16.0 ftZ 1 ft 0 in 10 ft 2 in Drapes/bfinds None 7 N=>SW 6 Metal Low-E Double Yes 0.56 0.28 48.0 ft� 1 ft 0 in 0 ft 8 in Drapeslblinds None 8 N=>SW 6 Metal Low-E Double Yes 0.56 0.28 23.0 ft' 1 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 9 S=>NE 7 Metal Low-E Double Yes 0.54 0.31 32.0 ft' 1 ft 0 in 0 ft 8 in Drapes/blinds None 10 S=>NE 7 Metal Low-E Double Yes 0.54 0.31 23.0 ftZ 1 ft 0 in 0 ft 8 in Drapes/blinds None 11 W=>SE 9 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None 12 N=>SW 6 Metal Low-E Double Yes 0.56 0.28 13.4 ft2 1 ft 0 in 0 ft 8 in Drapes/biinds None 13 W=>SE 4 Metal Low-E Double Yes 0.54 �.31 6.0 ft' 1 ft 0 in 10 ft 2 in Drapes/blinds None 6/13/2017 9:57 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Soflware Page 3 of 5 � , ' FORM R405-2014 � GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 599 ft2 606 ftz 77 4 ft 9.3 ft 1 ' INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000383 3732.6 204.91 385.37 .3532 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.5 21.8 kBtu/hr 1 sys#1 2 Electric Heat Pump None HSPF:8.5 21.8 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:16 25.2 kBtu/hr 756 cfm 0.85 1 sys#1 2 Central Unit Split SEER: 16 25.2 kBtu/hr 756 cfm 0.85 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage �� Cert # Company Name System Model# Collector Model# Area Volume FEF i None None ffZ �� DUCTS / —Supply— --Retum— Air CFM 25 CFM25 HVAC# U # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 1st Floor 6 343.6 ft 1st Floor 85.9 ft2 Default Leakage 1st Floor (Default) (Default) 1 1 2 Attic 6 400.4 ft 2nd Floor 100.1 ft Default Leakage 2nd Floor (Default) (Default) 2 2 6/13/2017 9:57 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 J � • FORM R405-2014 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb [ ]Mar A r Ma X Jun [X]Jul [X]Au [X]Se [ ]Oct Nov Dec Heating �Jan �Feb [X]Mar ��Apr f �May 4 �Jun [ ]Jul [ ]Au9 [ ]SeP [ ]Oct �Nov �Dec Ventin Jan Feb [X]Mar A r [ Ma [ Jun [ ]Jul [ ]Au [ ]Se [X]Oct Nov Dec Thermostat Schedule. HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(V1/D) AM 78 78 78 78 78 78 78 78 80 80 SO 80 PM SO 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) i4M 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 , 68 68 68 68 68 68 68 68 68 66 66 Heating(V11EH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 1 -Electric Heat Pump 0% 1 -Central Unit None 0 0 0 2-Electric Heat Pump 0% 2-Central Unit 6/13/2017 9:57 AM EnergyGauge�USA-FlaRes2014 Section R4�5.4 1 Compiiant Software Page 5 of 5 FORM R405=2014 - ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. ` „ FL, , 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1738.70 ftZ b.Concrete Block-Int Insul,Exterior R=4 1 1487.10 ftZ 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 199.11 ft2 4 Number of Bedrooms 4 d.N/A R= ftZ 10.Ceiling Types Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2002.00 ft2 6. Conditioned floor area(ft�) 3720 b.Knee Wall(Vented) R=30.0 132.00 ft� c.N/A R= ft' 7 Windows'* Description Area �1 Ducts R �' a. U-Factor Dbl,U=0.54 138.00 ftZ a.Sup: ist Floor,Ret: 1st Floor,AH: 1st Floor 6 343.6 SHGC: SHGC=0.31 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 400.4 b. U-Factor Dbl,U=0.56 123.36 ft2 SHGC: SHGC=0.28 12.Cooling systems kBtu/hr Efficiency c. U-Factor Dbl,U=0.56 106.67 ftZ a.Central Unit 25.2 SEER:16.00 SHGC: SHGC=0.32 b.Central Unit 25.2 SEER:16.00 d. U-Factor• N/A ftZ 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 21.8 HSPF:8.50 Area Weighted Average Overhang Depth: 3.098 ft. b.Electric Heat Pump 21.8 HSPF:8.50 Area Weighted Average SHGC� 0.303 , 8. Floor T pes Insulation Area 14.Hot water systems y � a.Electric Cap:40 gallons a.Floor Over Other Space R=0.0 1725.00 ft EF.0.95 b.Slab-On-Grade Edge Insulation R=0.0 '1718.00 ft' b, Conservation features c.other(see details) R= 277.00 ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy E�ciency Code for Building T�E.s� Construction through the above energy saving features which will be installed (or exceeded) � .`,Q� _ AT�o. in this home before final inspection. Otherwise, a new EPL Display Card will be completed j�k��',,,;�`"` f '=;-'�,i�'�,' based on installed Code compliant features. F"' 't+d���;,`<<:"':�";r°"."�,� � BuilderSignature. 06/13/17 � �W�mg .�� � Date. c� ���..�.. � �; �. � Address of New Home: 6502 Paden eel Street City/FL Zip Zephyrhills,FL 33541 '��� � �s"`� ��t�:W£'�'� "Note: This is not a Building Ener Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you o tain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "*Label required by Section R303.1.3 of the Flocida Building Code, Energy Conservation, if not DEFAULT. 6/13/2017 9:58 AM EnergyGauge�USA-FlaRes2014 -Section R405.4 1 Compliant Software Page 1 of 1 BV�Id�n i4nal $�$ Job: 3711AsfADS g y Date: 6/13/2017 lower floor By: Dave - Bayonet Plumbing Heating and Air ' • - s e For• Lennar Homes � - o o • • Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ftZ Btuh % of load Walls 5.6 7596 29.7 °0�5 Glazltlg 30.2 6195 24.3 wa��s nfiltration Doors 23.5 466 1.8 Ceilings 1.9 204 0.8 - Floors 3.6 6261 24.5 - Infiltration 18 2852 11.2 Ducts 1972 7.7 . Fioo� Piping 0 0 Humidification 0 0 �'�= Glazing Other Ventilation 0 0 Adjustments 0 Total 25546 100.0 � • o . Component Btuh/ftZ Btuh % of load Walls 2.8 3779 18.8- Intemal Gains Glazing 49.7 10206 50.9 waus Doors 18.4 365 1.8 Ceilings 2.5 260 1.3 ucts Floors 0 0 0 Infiltration 0.4 617 3.1 ! Infiltration D ucts 2274 11.3 " Ventilation 0 0 otner Internal gains 2560 12.8 Blower 0 0 Adjustments -� Glazing Total 20060 100.0 Latent Cooling Load=2081 Btuh Overall.U-value= 0.155 Btuh/ft2-°F Data entries checked. t Wrl h�Sm�" 2017-Jun-13 09:28:17 ^� 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 � ...th CBA27UHE AH's13711Asf ADS drawn 2+2tons.rup Calc=MJ8 Front Doorfaces: S ,` �V��d�� Anal $�$ Job: 3711AsfADS � Y Date: 6113/2017 upper floor By: Dave Bayonet Plumbing Heating and Air " • - • a For� Lennar Horimes � - 0 • • e Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 ', � Component Btuh/ft� Btuh % of load Walls 3.8 6127 32.3 ���5 Glazing 30.2 4967 26.2 Doo�s 0 0 0 wa��s Cellirlgs 1.3 2511 13.2 nfiltration Floors 0 0 0 Infiltration 1.8 3205 16.9 D ucts 2143 11 3 Piping Q � Ceilings Humidification 0 0 Ventilation 0 � Glazing Adjustments 0 Total 18954 100.0 oe . Component Btuh/ftz Btuh % of load Walls 2.7 4424 22.3 Intemal Gains Glazing 46.2 7602 38.3 waus oucts Doors 0 0 0 Ceilings 17 3472 17.5 Infiltration Floors 0 0 0 Infiltration 0.4 693 3.5 D ucts 2459 12.4 Ventilation 0 0 Ceilings Internal gains 1190 6.0 Blower 0 0 Adjustments 0 Glazing Total 19840 100.0 Latent Cooling Load=2473 Btuh Overall U-value= 0.-092 Btuh/ftZ-°F Data entries checked. ,� wri htsoft` 2017-Jun-13 09:28:17 ' ,�. 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page 2 � .th CBA27UHE AH's\3711Asf ADS drawn 2+2tons.rup Calc=MJ8 Front Doorfaces: S Pro ect Summa Job: 3711AsfADS 1 � Date: 6/13/2017 lower floor By: Dave Bayonet Plumbing Heating and Air . � . . ` -. For� Lennar Homes N otes: i - • • e Weather Tampa InternationalAP, FL, US � Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F . Inside db - 70 °F Inside db 75 °F Design TD 39 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 55 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 23574 Btuh Structure 17786 Btuh Ducts 1972 Btuh Ducts 2274 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25546 Btuh Use manufacturer's data y Rate/swing multiplier 1 00 Infiltration Equipment sensible load 20060 Btuh Method Simplified Latent Cooling Equipment Laad Sizing Construction quality Semi-tight � Fireplaces 0 Structure 1679 Btuh � Ducts 402 Btuh Central vent (0 cfm) 0 Btuh I Heating Cooling (none) Area(ftZ) 1718 1718 Equipment latent load 2081 Btuh Volume(ft') 17710 17710 Air changes/hour 0.22 0.12 • Equipment Total Load (Sen+Lat) 22142 Btuh Equiv.AVF(cfm) 66 34 Req. total capacity at 0.85 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary , _ Make Lennox Make Lennox - Trade 14HPX SERIES " Trade 14HPX SERIES Model 14HPX-024230-21 Cond 14HPX-024-230-21 AHRI ref 10258598 Coil CBA27UHE-024230*++TDR . AHRI ref 10258598 Efficiency 8.5 HSPF Efficiency 13.5 EER, 16 SEER Heating mput Sensible cooling 21420 Btuh Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh Temperature rise 25 °F Total cooling 25200 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.031 cfm/Btuh Air flow factor 0.040 cfm/Btuh � Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.91 Capacity balance point= 36°F Backup: Input= 8 kW, Output=26903 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .� wri htsoft^ 2017-Jun-13 09:28:17 �� g Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 ...th'CBA27UHE AH's\3711A sf ADS drewn 2+2tons.rup Calc=MJB Front Door faces: S � , ' � ' Pro ect Summa Job: 3711A sf ADS � � Date: 6/13/2017 upper floor By: Dave Bayonet Plumbing Heating and Air e s � • For: Lennar Homes N otes. i - e e s Weather: Tampa InternationalAP, FL, US , Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F I Inside db 70 °F Inside db 75 °F I Design TD 39 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 55 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 16810 Btuh Structure 17381 Btuh Ducts 2143 Btuh Ducts 2459 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh � Equipment load 18954 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 19840 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2038 Btuh Ducts 435 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ftZ) 2002 2002 Equipment latent load 2473 Btuh Volume(ft') 16014 16014 Air changes/hour 0.28 0.14 Equipment Total Load (Sen+Lat) 22312 Btuh Equiv.AVF (cfm) 74 39 Req. total capacity at 0.85 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary ' Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-024-230-21 Cond 14HPX-024230-21 AHRI ref 10258598 Coil CBA27UHE-024230*++TDR AHRI ref 10258598 Efficiency 8.5 HSPF Efficiency 13.5 EER, 16 SEER Heating input Sensible cooling 21420 Btuh Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh Temperature rise 25 °F Total cooling 25200 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.042 cfm/Btuh Air flow factor 0.040 cfm/Btuh Static pressure 0 irrH2O Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.89 Capacity balance point=28°F Backup: - Input= 6 kW, Output= 20366 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. � wri htsoftn - z017-Jun-13 09:28:17 �A g Right-Sulte�Universal 2017 17.0.23 RSU05714 Page 2 ...th CBA27UHE AH's\3711Asf ADS drawn 2+2tons.rup Calc=MJS Front Doorfaces: S V f Ji Manual S Corv�pliance Report Job: 3711AsfADS Date: 6/13/2017 lowerf�oor By: Dave Bayonet Plumbing Heating and Air ' a - • a For• Lennar Homes - • • e • e Design Conditions Outdoor design DB: 91.3°F Sensible gain: 20060 Btuh Entering coil DB: 75.7°F Outdoor design WB� 77.3°F Latent gain: 2081 Btuh Entering coil WB� 62.9°F Indoor design DB: 75.O�F Total gain: 22142 Btuh Indoor RH� 50% Estimated airflow� 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SpIitASHP Manufacturer: Lennox Model: 14HPX-024230-21+CBA27UHE-024230*++TDR Actual airflow� 800 cfm ' Sensible capacity: 21420 Btuh 107% of load Latent capacity� 3780 Btuh 182% of load Total capacity� 25200 Btuh 114% of load SHR. 85% • e • Design Conditions Outdoor design DB. 30.8°F Heat loss 25546 Btuh Entering coil DB 69.6°F Indoor design DB• 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Lennox Model: 14HPX-024230-21+CBA27UHE-024230'`++TDR Actual airtlow: 800 cfm Output capacity� 21800 Btuh 85% of load Capacity balance: 36 °F Supplemental heat required: 3746 Btuh Economic balance: -99 °F � Backup equipment type: Elec strip Manufacturer Model: Actual airflow� 800 cfm Output capacity' 7.9 kW 105% of load Temp. rise: 50 °F Meets are all requirements of ACCA Manual S , .�, wri htsoft'� 2017-Jun-13 09:28:17 �� 9 Right-SuOe�Universal 2017 17.0.23 RSU05714 Page 1 .th CBA27UHE AH's13711Asf ADS drawn 2+2tons.rup Calc=MJS Front Doorfaces: S � - - , ., , Manual S Com liance Re ort Joh: 3711AsfADS p p Date: 6113/2017 u er floor Bv: oa�e PP Bayonet Plumbing Heating and Air � • ' i • For: Lennar Homes • • e • . Design Conditions ` Outdoor design DB: 91.3°F Sensible gain: 19840 Btuh Entering coil DB 75.7°F Outdoor design WB• 77.3°F Latent gain: 2473 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 22312 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions � Equipment type: SpIitASHP Manufacturer: Lennox Model: 14HPX-024-230-21+CBA27UHE-024-230*++TDR Actual airflow: 800 cfm Sensible capacity: 21420 Btuh 108% of load Latent capacity: 3780 Btuh 153% of load Total capacity� 25200 Btuh 113% of load SHR. 85% • e • Design Conditions Outdoor design DB 30.8°F Heat loss. 18954 Btuh Entering coil DB 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer Lennox Model: 14HPX-024230-21+CBA27UHE-024230*++TDR Actual airflow: 800 cfm Output capacity: 21800 Btuh 115% of load Capacity balance: 28 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec.strip Manufacturer Model: Actual airtlow� 800 cfm Output capacity� 6.0 kW 107% of load Temp. rise: 50 °F Meets are all requirements of ACCA Manual S. .�, wri htsoft'� 2017-Jun-13 09:28:17 �� 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page 2 ..th CBA27UHE AH's13711A sf ADS drawn 2+2tons.rup Calc=MJS Front Door faces: S