Loading...
HomeMy WebLinkAbout252 Mobile Home Set-up - Le •;i v 1 N'tr (1..1-C� k �o ORDINANCE NO. o250Z AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF ZEPHYRHILLS, FLORIDA, REQUIRING AN ISSUANCE OF A SET-UP PERMIT FOR ANY MOBILE HOME PLACED WITHIN THE CORPORATE LIMITS OF THE CITY; PRO- VIDING MINIMUM REQUIREMENTS FOR SETTING UP OF SUCH MOBILE HOME; PROVIDING FOR THE FEE FOR SUCH PERMIT AND FURTHER PROVIDING FOR PENALTY FOR VIOLATION' OF SAID ORDINANCE. BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF ZEPHYRHILLS, FLORIDA, as follows : SECTION 1 : That all mobile homes placed within.. the : corporate limits of the City of Zephyrhills, following the ef- fective date of this ordinance, shall secure a set-up permit from the Building Inspector of the City of Zephyrhills. ' SECTION 2 : That at the time of requesting said set-up permit referred to in Section 1 , the owner or other person or organization setting up said mobile home shall provide the Building Inspector with the following information : 1 . Legal description of property where mobile home is to be placed. 2. Availability of city water and sewer services to said land. 3. Size of mobile home to be placed on said land . SECTION 3 : That prior to the issuance to said set-up permit the following minimum requirements must be complied with by the person, firm or organization requesting said permit, as follows : (A) STRUCTURAL SET-UP.: Mobile Home Set-Up and Repair License. 1 . Foundation block must be minimum of 16" X 16" X 4" solid concrete set on solid clean compact soil conditions . 2. Piers shall consist of 8" X 8" X 16" concrete blocks with cells set vertical and length of block to be perpendicular to frame beams. Where pier heights exceeds three blocks; all piers shall be double. 3. Cap blocks shall be 4" X 8'.' X 16" solid concrete. { 4. Shims shall consist of treated wood and should be held to a minimum for leveling purposes. .5. Center to center of piers shall not exceed 10' and piers shall be placed at distance of no more than 2" from ends of frame beam. 6. Hurricane anchors shall be installed using 6" disc on 5/8" rods, and adjustable type fasterners for strap connections. Maximum spacing of hur- ricane anchors shall be not more than 10' or as provided by locations of hurricane straps as installed by manufacturer. If hurricane straps not built in as per mobile home manufacturers code, then top of living unit strap shall b.e . installed with maximum spaces not to exceed 10' on- centers. Minimum length of anchor rod shall be 48". 7. RE : ' Tie Down. Standards : Up to 40' 41 ' to 60' 61 ° & up Frame ties per side 3 3 5 7 Over the roof ties per side 3 3 3 Number of anchors per side 3 5 7 8. RE : Hurricane anchors : Each model must be certified by an independant testing laboratory, recognized in the State of Florida. Each model must be tested and certified to destruction and to soil types. Certification subject to approval by Zephyrhills Building Inspector. (B) SEWERS AND DRAINS : , 1 . All exposed sewers under living unit must be supported every 4' . All slopes on sewer an'd drain line should be minimum of 1/4" per foot all the way to the septic tank with no sags or low spots. SECTION 4: That all blocking for the installation of said mobile homes shall be as set, forth in regulations attached hereto and designated as Exhibit #1 , same being incorporated inand made a part of this ordinance.. t SECTION 5 : That all mobile homes presently, installed and tied down in compliance with requirements of the owners in- surance company or approved by a.:governmental unit, shall be deemed to have complied with the tie down standards of this ordi- nance. That upon relocation of such mobile home the above tie down requirements shall apply. SECTION 6 : . That all such applicants for set-up permits shall pay to the City of Zephyrhills a sum of ten dollars ($10.00). -2- r SECTION 7 : This ordinance shall become effective im= . mediately upon date of enactment. SECTION 8 : Anyone found guilty of violation of this ordinance shall be subject to pay a fine of not more than five - hundred dollars ($500.00) or ninety days (90) in jail, or both in the discretion of the Municipal Judge. The foregoing Ordinance No. As-a was read and passed on its first reading by the City Council of the City of Zephyr- hills, Florida, on the 10th day of November , 1975. pr- President of City Council . Attest : ----. ------ -- -- e,0 ,,4 . . C . y Clerk 6r . The foregoing Ordinance No. L.5-01, was read and passed on its second reading by the City Council of the City of Zephyr- hills, Florida, on the -24 th day of November , 1975. 4 100'. /e/ )4/,'A/A4e-Z: - - `President of City Council Attest : : 1h✓ ty Manager . ___ - -" The foregoing Ordinance No. o2,5"- - was read and passed on its third ' reading by the City Council of the City of Zephyr- hills, Florida, on the _ 8th day of December , 1975. `i l ti_ President of City Council ___T7:,Attest : i--.-- / , - ity, .danger The foregoing Ordinance No. 2,5a- was approved by me this 9th day of December , 1975. 31 , 11-3 4 4,,,t-if Mayor I/ Publish 1 week ' - November 20, 1975 -3- i (' ' :'rte W `, `', I t Or ...'; . ' i • I - FLUOR /\\/\11 '1 /. --- —er . 1 .',4 ,IL a GROUND LEVEL Provided, that those mobile homes which arc presently tied Gown 1?� compliance with the requirements of the insurance company1 nsuring sure, or the city or county wherein such mobile homes are located, and have been approved by the insurer, shall be deemed to have complied with the tie-down standards of the department as set forth on the attached (pages. Upon relocation of such mobile homes, however, the department tie-down requirements shall apply. EXHIBIT #1 ' f FIGURE I _ - -_... .._. ..._, _ __ . Blocking (single tierod) -+ r (All corners must be doubled tiered and Maximum -- blocks interlocked, if more than three(3) 401° -�- ._ blocks high) -Beam Frame ood shims i ` � Cap- Pressure treated 2i1 x 8" x 16" or ( equivalent v ___ _ Solid or celled Concrete blocks Footer-l6" x 16" x 4" Solid or equivalent FIGURE II ,.` L Flocking (double tiered & blocks inter- I „r locked) . Maximum 11:::::.====-J'-4___ -I-Beam Frame 800° ' Wood shims tion) Pressure treated wood plate - Cap- 16" x 16" x 4S1 Solid block or equivalent Solid or celled ' I - • " , Concrete block Footer or pier foundation ` 16" x 16" x 4" solid block or equivalent v FIGURE III �. Lam_ _LBlocking (double tiered-blocks interlocked concrete filled) _ I Beam Frame A s j••:•.. I Wood shims . (Option) Pressure treated wood plate i. Cap 16" ,x 16" x 4" Solid blocli. or equivalent Maximum ,', 80" ���' 3/8" Steel reinforcement rods I �� Celled concrete block ":7----4.---,-1. All cells filled with 2500 P,S,I. concrete 1. , - .4 Footer or pier foundation • I . _ B-locking (solid pier) I-Beam Frame FIGURE IV Wood shims (Option) Pressure treated wood plate Maximum " x10" (minimum) pier' top 24' . t `I 'ier Footer or pier foundation 16" x 16" x 4" solid block or equivalent •. : /.� I- r . 1 I - :- :-. - - I NI /map