HomeMy WebLinkAbout17-18700 --�
, CITY OF ZEPHYRHILLS
L. 5335-8TH STREET %"�
� (813)780-0020 18700'"r
B�JILDIMG PERMIT SINGLE FAMILY RESIDENTIAL -�`�f
PERMIT IfdFORMATtON LOCATION INFORMATION
Permit#:18700 Issued: Address: 6527 PADEN WHEEL ST
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 358,220.48 Total Fees: 11,808.69 Subdivision: SILVERADO
Amount Paid: �� �Ll�j'r Date Paid: ' �Q--I Parcel Number: 05-26-21-0070-00400-0060
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES INC
Addr: 15550 LIGHTWAVE DR Address: 4600 W. CYPRESS ST STE 200
CLEARWATER, FL. 33760 TAMPA, FL 33607
Phone: (727)479-1740 Lic: Phone: 813-574-5700
Work Desc: CONSTRUCT SINGLE FAMILY 3,368
APPLICATION FEES �
B ILDING FEE 1,37029 ELECTRICAL FEE 284.63 PLUMBING FEE 189.75
MECHANICAL FEE 132.83 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00
SCHOOL IMPACT FEE-sfd 1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
� �
�
U� /�' � �
���� ��,�����1 � �
N
Ins ections Re uired
FOOTER 2ND ROUGH PLUMB MIS INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC. �
ROUGH ELECTRIC LINTEL MISG MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTOR SIGNATURE PERMIT OFFI
PERf�IT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER �I
_ _ . iii0iiiiiiiiiiiiiiiiiiiioiiiiiiiiiiiiiiiiiiiiiiiiiiiii
� ' 201711677?, IIIIII
��____---
Rcpt:188192� Rec: 10.00.
' DS: 0.00 IT: 0.00
-_ _07/25/2017 K. M. , Dpty Clerk
PRULR S 0'NEIL,Fh D PASCO CLERK & COMPTROLLE
�_ - 07/25/201�'��m 1 ����
" OR BK G� PG
Permit No. Parcel ID No 05-26-21-0070-00400-0060
NOTICE OF COMMENCEMENT �
State of Florida County of PaSCO -
THE UNDERSIGNED hereby gives notice that improvemerit will be made to certain real property,and in accordance with Chapter 713,Florida Statutes;
the following information is provided in this Notice.of Commencement:
1. Description of Property� Legal SILVERADO RANCH SUBDIVISION PHASES 2,3.&4 RB 73 PG 59 BLOCK 04 LOT 06
st�eeraaa�e5s. 6527 Paden Wheel Street Zephryhills FL 33541
2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence
3. Owner Information: Lentiar Homes, LLC
Name
4600 W Cypress St. Ste 200 Tampa FL. 33607
Address City State
Interest in Property�
Name of Fee Simple Titleholder: N�A
(If other than owner)
Address - City State
a. contractor� Lennar Hbmes, LLC
Name
4600 W Cypress St, Ste 200 Tampa FL, 33607
Address City State
Contractor's Telephone No.: $13 574 5700
5. Surety: 4...,.'':� N/A
Name
Address City State
Amount of Bond. $ Telephone No.
s. �ender N/A �
Name
_Address City State
Lender's Telephone No
7 Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by •
Section 713 13(1)(a)(7),Florida Statutes:
Lennar Homes. LLC �
�Name
4600 W_Cypress St, Ste 200 Tampa I FL; 33607
Address City � State
Telephone Number of Designated Person: 813.574.5700
8. In addition to himself,the owner designates N/A of
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner•
9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: �
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT I
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE i
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR'NOTICE OF COMMENCEMENT.
STATE OF FLORIDA � �j
COUNTY OF PINELLAS , � �
Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager
Vice President
Signatory's Title/Office
The foregoing instrument was acknowledged before me this �5 day of March �0►1 ,by -
Steve Robert Smith as VICe President (type of a i y,e.g.,o r,trustee,attorney in fact)for
Le_n_nar Homes. LLC (name of party o beh hom instrument was executed)
�
Personally Known�OR,Produced ldentification� Notary Signa e
TyPe of Identification Produced Name(Print) ISSa olleran
Verification pursuant to;Section 92.525,Florida Statutes. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in
it are true to the best of,my knowledge and belief.
� =�����,,� ELISShM.HOLI.ERAN Sigrrature of Natural Person Signing Above
r:�C�minl�alon t�FF 885837
` . r`.Ex'Ires dune 6,202p , ; i
wpdata/bcs/bcs form� ,�R���''��9cndNThiuTroyFelnlMu�nal00a0.5�7010
�
. ,
� � , ��,��
, � ° s ��' ;' �p��� ST�.`��OF FI n��nv r.n����v nF�Q�CO
� ` °g`�"�' �� ��c THIS IS TO CERTIFY THAT THE FOREGOING IS A
� B =,����� : e�n TRUE NIVD CORRECl�COPY OF THE DOCI IMENT
� �.� O.f�;F,�L��f�,.QF,,PUBLfC:RECORD IN,THIS�OFFICE
p � �,_ �.,,. _ ,.., _. . �...a.,
� , '��. * WITNESS�Iv I�A`N " � O�.FIC ,L�SEX1LTMtS
� �. � �� DAY b � 2��
���. e • � PAULA S. O'NEIL,G � 7 - ER
�ni°F{,�,�1� gY ,�_ PUTY CLERK
_�j o
v��s
f�l:QA1�ifl_
• • ,5��y��i-,r
-.$''+K`
�-��'.`
4` �: .
- J
City of Zepliyrnills
BUILDING PLAN REV,IEW COMMENTS
Contractor/Homeowner: ������--`'�""�"�,�
-- --- - -- — -� -- ---- - -- ------ - - -- - — ---- ----- - ---
Date Received: � � ��
Site: l � Q��� (��
,
Permit Type: ' F;%� v'� � G� �a
i
,
;
; Approved w/no comments:❑ Approved w/the below comments: � Denied w/the below comments: ❑
/
I ��
�I
��,
This comment sheet shall be kept with the permit and/or plans.
/-
,! �-a a-�7
; Kalvin witzer lans Examiner Date Contractar an or Homeowner
(Required w en comments are present)
, � : PAaC� ��tJNTY, F�.�R[D�,
t
. . . Permi#No. l� ��
, � Date Permitted -�'�i'-�?�/7
� Builder Name/Owner Name �,.e{2,✓trzr��9Y►Z.r�sSt..tYZ�:e Cantrol#
CountyParcelNo, (��-�-2-(-o0�e-��DO-�Q��SubDiv:
AddressJLocation (,�Z7 ?"!.�-Gi£Y'1 �tl�y�s22.f ��
ClassificationfType af Use �i✓i,Q!�r�vi� �G(
TRANSPORTA7IC?N IMPACT FEE Rate: Sq.Ft Unit: �--����—
Exempt �Yes [� No Now Determined
� impact Fee Amaunt $_� (��2, Zone No. 'fAZ:
SCHOOL IiIAPACT F�E
Account (056) Singie-Family Detached}iouse Amount $ �� �7�� � i
(457) Mabile Home
(058) Other Resldential
123) Gallection Fee
Exernpt [� Yes � No Now Determined
PARKS AND RECR�ATIQN FEE
i,
Land Account Land Credit Land Totai
Recreatian Accaunt Recreation Credit Recreation Totaf
Zane � TOTAL AMOUNT $ 7(�Q�5F, I
Exempt []Yes [� No How Qetermined
� �LIBRARY FEE �
Land Account Land Credit Land Totai
i
Facility Accaunt Facility Credit Facifity 1"otaf
� Exempt ❑ Yes ❑ Na How Determined Total Amount ��� '�
RESOURCE FEE ERU
TO7AL AM(�UNT '
Prepared By ` Checked By -
NO CERTiFICJ�TE OF t3CCUPANCY W1LL BE tSSUED OFt FINAL INSPECTiON
PERFORMED UNTfL THE TGiTAL AMOUNTS USTED NAVE
BEERi PAID At3D
RECEIP7ED FOR BY A CEhl7RAL PERMITTING OFFICE OF PASCO COUI�ITY
Acknowledgement below doas not lmply acceptance of concurrence,but simply recelpt of a copy of thls torm,placing
tha buiidEng permit owner on noHce of this assassment and the conditions af payment for same.
�
� DATE RECE{VED BY
RECEIPT NO. DATE 8Y
� I
I �
T .�.,�.��,.�..�..._-.�_Y.__,�_.�`__� --- �
_�.,-_a:��
"s�a-�ao-oo2o City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received �
Phone Contact for Permittin 813 363 __ 2891
�_r_i—
Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700
Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number
Fee Simple Titleholder Name N�A Owner Phone Number
Fee 5imple Titleholder Address N�A
JOB ADDRESS 6527 Paden Wheel St�eet LOT# 0060
SUBDIVISION Silverado Ranch Subdivision Ph 2,3,84 pARCEL ID# 05-26-21-0070-00400-0060
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED II./ II NEW CONSTR e ADD/ALT � SIGN � � DEMOLISH
� INSTALL REPAIR
PROPOSED USE � SFR Q COMM 0 OTHER
TYPE OFCONSTRUCTION � BLOCK Q FRAME � STEEL �
DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence
BUILDING SI U/R SF 3368 SQ FOOTAGE 2599 ��a� HEIGHT � StOry
rrrrrrrrrr—r—rrreTr'1'rrrr�r—r'r'e�—rrT1"rr r �
✓ BUILDING $ � / 6 � VALUATION OF TOTAL CONSTRUCTION '
b
I�/ 'ELECTRICAL $ � PROGRESSENERGY Q W.R.E.C.
' � ` AMP SERVICE
�PLUMBING $ _�
���/ �MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
, . �
�GAS � ROOFING Q SPECIALTY � OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA �YES �O
u
-��E-4:E-�-�Na-:-:-:-r-tr--E.��+a-:-;-r:-:-E-�-�--���+��+�+��-:-'-:--:-�-�--���-+��+��E-�--�-a-�-E-+--�-E-
BUILDER COMPANY Lennar Homes,LLC
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 4600 W.C ress St.Ste.200,Tampa,FL 33607 License# CGC1518166
ELECTRICIAN �,� COMPANY Edmonson Electric, Inc.
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 1034 Ski er Road,Tampa, FL 33613 License# EC13005408
PLUMBER COMPANY gayonet Plumbing, Heating &AC, Inc
SIGNATURE �� REGISTERED Y/ N FEE CURREN Y/N
Address P.O. Box 530 , Bayonet, FL 34674-5308 �icense# CFC042998 !
MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGNATURE v REGISTERED Y/ N FEE CURREN Y/N
Address P O Box 5308 ayonet, FL 34674-5308 �icense# CAC058062 I
OTHER COMPANY
SIGNATURE �— REGISTERED Y/ N FEE CURREN Y/N
Address 4211 Shoal Li e Blvd, Spring Hill, FL 34607 �icense# CCC057991
� � � � � � � � � � � � � � � � � � � tt � t � � � � � � � � � � � � � � � � � � � � � � � t � � � t � � � � � � � � � � tt � � � �
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities 8�1 dumpster;Site Work Permit for subdivisions/large projects
CONiMERC1AL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
"*""PROPERTY SURVEY required for ali NEW construction.
..�a—f..�L.i�l—��'.-.:—:..'.' 1..1..4�f—i—I..�f�l-.f�.��1..1..4�1..1—���1--1—�1..1..1-1..4.L.-L�1..��1--k�—Le�f••1..4.L�����1..�1..
Directions:
Fill out application completely
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) -
"" Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(PIoUSurvey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS� The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any �
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009 Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended)� If valuation of work is$2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's ,
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone I
I other than the"owner°, I certify that I have obtained a copy of the above described document and promise in good faith to �
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT I certify that all the information in this application is accurate and that all work I
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is ,
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has ',
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating I
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment. •
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement. � ,
- Federal Aviation Authority-Runways.
' I understand that the following restrictions apply to the use of fill
- � Use of flll is not allowed in Flood Zone"V" unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flobd Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the 6uilding Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid �
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension If work ceases for ninety(90) consecutive days, the job is considered abandoned
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S.117 03)
OWNER OR AGENT CONTRACTOR .
Subscribed and sworn to(or affirmed)before me this Subscribed and swom to(or a�rmed)before me this
i a-iviay-i i by paul Sweeney ,5-Mev-,� by Paul Sweeney
� Who is/are personally known to me or Who is/are personally known to me or
as identification. as identification.
Notary Public Notary Public
Commi ion No. FF98537 Commission No. rr98537
Elissa M.Holleran Elissa M.Holleran
Name of NotaN tvped,printed or stamped Name of Notary typed,printed or stamped
".""'� �, �tI���H�P��tt�hW
pp{ yo�, t�p�1p p�y6� ��
;P•�I11., FRl�bW��rF1U{.yL`e'+J1I� �
a ��#Rt1f�S'Sfl1NpP8�dp�j
� , C�(r�tr��'�nsMNP9t�a�� � ,,�r;Flp9��idi��d'��d��
�p eT�LA��#�IhJts!<'d,���� ���'" 8��18araFa��i�5�in4Gt#��d1F3G�1
@T.i.� �Nt�S1CJi:Tl�'�7�S19fl�dl�^�rd^��I � . ..._
' • 6527 Paden Wheel- Lennar Home-3368 sq ft
o umn
SQ. FEET PRICE
MAIN OR LIVING: 3,368 $ 106.36
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 358,220 48
FEE SHEET $ 1,265.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,370.30
ELECTRICAL: $ 284.63
PLUMBING: $ 189.75
MECHANICAL: $ 132.83
SUB-TOTAL $ 1,977.50
TOTAL $ 1,977.50
SEWER: n/a
WATER: n/a
IRRIGATION: $ -
TOTAL: $ -
WATER METER: n/a
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL: I
' PERMIT TOTAL �
TOTAL: $ - n/a
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 2,530.85
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00 N/A
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00
• 99% $ 3,595.68
1% $ 36.32
TOTQ►L: $ 11,808.69
� • 6527 Paden Wheel
o mn
SQ. FEET PRICE
UNDER ROOF: 3,368 $ 106.36
�
OTHER: j- $ -
VALUATION $ 358,220.48
i
i
FEE SHEET $ 1,265.00
I
ADDRESS $ 40.00
DRIVEWAY $ 40.00
I
BUILDING: ,$ 1,370.30 �
ELECTRICAL: $ 284.63
PLUMBING: $ 189.75
MECHANICAL: $ 132.83
SUB-TOTAL $ 1,977.50
i
TOTAL $ 1,977.50
I
SEW ER: I
WATER:
IRRIGATION: $ -
' TOTAL: $ -
WATER METER:
IRRIGATION METER
FIRE DEPARTMENT FEES
PLANS TOTAL:
� INSPECTION TOTAL: �
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 2,530.85
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00
99% $ 3,595.68
, 1% $ 36.32 I
TOTAL: $ 11,808.69 �
Single Family Dwelling
Plan Review Comments
1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan.
2. Lots shall be graded to comply with R401.3 of the F.B.C.
, 3. Compaction test required if 24" or more of fill dirt is brought in at any one place.
4. Tie in survey required before pouring concrete.
5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have
expansion material.
6. All setbacks shall be met.
7. All property markers shall be uncovered and marked at time of first inspection.
8. All A.D.A. requirements shall be met.
9. No electric, plumbing, mechanical, or framing shall be covered without an inspection and
approval first.
10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).
11. Appliances shall not be installed in a location where subject to mechanical damage unless ,
protected by approved barriers. M303.4 of the F.B.0 �
12. Water heaters shall comply with section P607.3 of the F.B.C. �
13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1
14. Return air in all bedrooms. F.B.C. M1620.4
I 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C.
16. All glazing requirements are to be in accordance with R308.4 of the F.B.C.
17. All means of egress are to be in accordance with R311 of the F.B.C.
18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C.
19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker.
20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating
or appliances or an attached garage. They shall be installed in accordance with the F.B.C.
21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all
underground plumbing and electric.
22. A112008 N.E.C. Codes will be enforced.
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0
22. In accordance with the Land Development Code, lots shall be sodded before final at least 10
feet around the structure.
F.F.E.-Finished Floor Elevation
F.B.C- Florida Building Code 5�'Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008)
�L�,.1,P�� SKETCH ONLY SEC. 05 , TWP. 26 S, RNG. 21 E.
NOT A BOUNDARY SURVEY
LOT 6, BLOCK 4 � BEARING BASIS:
SILVERADO RANCH SUBDIVISION NORTH BOUNDARY OF SE� OF 05-26-21 BEING N 89'25'01" E
PHASES 2, 3 & 4
PASCO COUN�TY, FLORIDA. �T THIS SURVEY IS SUBJECT TO ANY FACTS THAT
j� MAY BE DISCLOSED BY A FULL AND ACCURATE
11TLE SEARCH. ALSO SUBJECT TO SEIEACKS,
�PCP(P) EASEMENTS AND RESTRICTIONS OF RECORD.
r�oi UNDERGROUND FOOTER, STEM WALL, AND
� �� UNDERGROUND UTILITIES ARE NOT LOCATED OR
� SHOWN.
�o, w DO NOT SCALE THIS PRINT. DIMENSIONS AND
6`�• �O ¢ NOTES TAKE PREFERENCE.
U
�6� O,(� � DESCRIP110N NOT CONTAINING PLAT BOOK AND�
�° `/�� PAGE INDICATES THAT PLAT IS IN
a�6 " V PREIIMINARY STAGE AND IS SUBJECT TO
� (�Q,�Gl/,(, CHANGE AND/OR REVISION.
PCP(P) `q�FS�`C ENGINEERING PTLANSH ROVIDEDRBY� CLIENT.ED ON
�/pp�NT r�qcTS� STRUCTURE T1ES SHOWN HEREON DENOTES
� <J �� MEASUREMENT FROM FORM BOARDS/FOUNDAl70N
�` TO PROPERTY LINE.
\ PRELIMIi�lARY DRAWLNG:
THIS PLAN IS FOR PERMITTING PURPOSES
�' ONLY, NOT FOR CONSTRUC110N. VERIFY
' yS2s, - ALL DIMENSIONS BEFORE ANY CONSTRUCTION.
s 3.
8������y _ - . °�a�' = LEGEND:
;:'-,C17�}.� .;_ '....,'.,~': .1-�= PROPOSED DRAINAGE FLOW
; ' oo" . (00.00) = PROPOSED GRADE
� * . ;'�,���� ' -,,,�o•�E-00.00 = EXISTING GRADE
' �� _. - �4 ',S.F„.
G�• � -' :' �OO" iVOTES:
. .���>�y LOT GRADING TYPE = B
• -�. +' �� ' / .-.�v. -• :..'�^ '�-. . G '• ^ '� � PROPOSED PAD ELEVATION = 109.5'
. .; � -./ h.• �'.� ���r \- :: _
— �^. o�� �a � "`?! '�°-'-' �� ': -`�_' �,. ` FRONT SET BACK = 20'
� � '•�i. . . .;ry�.,. ,�'�.' ✓ \ SIDE SET BACK = 7.5'
�• . , ry'� REAR SETBACK = 15'
-- �,.,.zs.00:;..;.�,, I
i.so• � ON LOT AREA CALGULATiONS
� = 9729.57
0
�.50' L T SQ. FT.
LIVING AREA = 2599 SQ. FT.
ENiRY = 36 SQ. �.
GARAGE = 586 SQ. �,
COVERED LANAI = 144 SQ. FT.
� PA110 =�A SQ. FT.
CONC. DRIVE = 826 SQ. FT.
PROPOSED PLpfd A/C & CONC PAD =�___SQ. FT.
� 2600
I n o ELEV'B^ PRIVATE SIDEWALK = 40 SQ. FT.
a I GARAGE LEFT IMPERVIOUS = 44 y,'
� o� � — 4240 SQ. FT.
oi z LOT 6 SOD � 5490 gQ, �,
�'� BLOCK 4 �- �
OFF LOT AREA CALCULATIOI�LS �
' o,' � RIGHT OF WAY = 1464.03 $Q, �.
BLOCK74 L°�� 50'-0" r�°9�y, LOT 5 pU8 CAS DEWALK = 543 SQ. FT.
w S 88'75'27'E �} BLOCK 4 _ ,
� SOD - 571 SQ. FT.
� ��50, L I �.so� `"� TOTALS
� AREA = 11193.60 SQ. F"r.
N A/C� • N DRIVEWAY = 1176 SQ. Ff.
� - • SIDEWALK = 583 SQ. FT.
� � ' SOD = 6061 SQ. FT.
� N:. �
¢ z y: ' �
� W. .� •
vi o- •a
: rn 'v-
M ' m=
o �"1 a a'
o:
n z. - ■ = 10' U1ILITY EASEMENT
o - '
� � � PROPOSED:
� • LOWEST FLOOR ELEVATIONS:
3 — LIVING AREA: 110.20'
� 50� N 88'35'27" .W 65.00' ��o GARAGE AREA:
; �°� '•soJ ELEVATIONS REFERENCED TO
� DRAIN GE AREA NORTH AMERICAN VERTICAL
m DESCRIP`fIOfV: DATUM OF 1988. MEAN SEA
� LOT 6, BLOCK 4, MAP OR PLAT ENTITLED LEVEL= 00.00 FT.
�
;' "SILVERADO RANCH SUBDIVISION PHASES 2,
a3 8L 4��, AS RECORDED IN PLAT BOOK 73, CURVE RADIUS ARC CHORD BEARING DELTA
= PAGES 59 THROUGH 65, OF THE PUBLIC c,�s 55.00' 12.95' t2.92' N 51'22'77" E is•zs•zs••
C774 25.00' 32.27' 30.08' N 8136'29" E 73'S7'49"
Z RECORDS OF PASCO COUNIY, FLORIDA. ci�s 337.00• ze.os• ze.os' S 63'47'45• E 04'46•n�
�
� APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL N0. 120230 0455 D EFFECTIVE DATE: 09/30/1992
0
� LEGEND:
j (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, �= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
N CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
/ F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
� PIPE, LFE= LOWEST FLOOR ELEVAl10N, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
Q REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= 7EMPORARY BENCHMARK,
� U P= UTILITY POLE, W F= WOOD FENCE, R = RADIAL
o Drawn By. Square Feet: 9729.57 t LENNAR HOMES I
a JOHN R.BEACH&ASSOCIATES,IiVC. � sMs
� SURVEYORS AND MAPPERS
� 911 WEST ST. PETERSBURG DRIVE Checked By.
in ONE OLDSMAR, FLORIDA 34677 JRB
� WAY (813) 854-1276 FAX (813) 855-8370 Scale:
c 1"=30' E=�f7'y"' '1� - !
0
�� NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 6 8 17 ACS
'v THE ORIGINAL RAISED SEAL OF A FLORIDA R. BEACH DATE
� IJCENSED SURVEYOR AND MAPPER FLORI EG. LAND SURVEYOR No. 2984 LB#4493
i Revisions:
�
� ' t5 ( � ,r ; _ � I ' ��v •. , �U" �+ �� � ,�, , . ,- •��� � � _
� .7 '{' � I
� r ,B-. _ �e� � 1 FF=109.60 - �� � �=7.oe.7o
,� �� � �_�os.so p � � � �
�V '°'�5 + - � �- � r I tOT 12 - t _ ��� �'o-, LOT Z LOi' 1 -�1 -- '•. 9�.
� i � PAD=108.9 ` � r -\ � � Q 1 9(,2 cj� 5 PAD=109.0 � ,r-�'•
i y7 ,. - _ U, � � � � � g � O C�T�- � �y j,�0' �, �E a '` i
r m � " ir 'ie- j �� �`� � 1 � FF=1 k6T�0 - a£�' ` ,� '`� . �
g � • ' ' °��` a- � ♦ �� �� ^ � � LOT 9 '�` , 5� ,� ' ,
} - �� '" ,s- � �" � PAD=1 Q9.6 `� � I
� @ 1 6' � '
�` ,�• , � n- r � �- �, � . �,�L� � �\ TYPE A �� �� �
,' ��� '`� . �r .i�- ro v' - M�, � � � � 1�0. �� ,,� ti
/r, is-c• �� " FF=1�9.50 ;� ,� � � -} . � � \ r , 1 9' ���
�` \ b� \ �'• ,� �' � ��- L0��11 �- ' �� ro� `o` V �� � ..
`, � - _ � 08.� l �'• ^ -�� ` O `1 �, � �Cc G` � .
w s-,o��s ��` 6� 6" ..� PE B �Y ~�� � � �1C �C �1 l Q,�Q � �i ,` �.�s �• �
� 3' � O `k
, .\� .ti �}, a�,- - � .- , o� S , '`, '-' � P�or�'�'�" g� o� °" ��° .�C ,�� � E
�a^Ts� O t �e s6 R �` AD=:11�.0 �� =� 'v1,^ �� FF=1t0.30 ` o ,
�� fi- , � TYPE A ° LOT 13 ' \
e-�o�e"� b�� �'`, . 1 _-- - � •� < � �. FFo1,10.80 FF=110.60 PA�E�A•6 � '�ti
c-,r ��, -2Q r_-�-'Q �' �ir � _ �. LO�T 12 l
.o• � � FF-108�,�' � O. . PAD=1 1�.1 PA�1 Q9.9 � '� 1
�\ ' ��� "- i ��Ts�l� � � o� � `�� TYPE A TYPE A � m
� �u PAD-T T i �'1 �•. � ``� , � � ��� / ^ �^ �4
��``` �,j s-e-,' 1lFP� �- _ i 6 b°" h" �O 10 � p c� QC C� �D� C'1 '1 . � �.
+.-�ti e ri ���� �� 4 '�1 --- 6 '�v --1� . 1� C�'7 .'� ^'�� -�`� 1 � �` �'�`� .'\ �'V �a �' `' �1 '-t� �,�� ,�� � n
�� � , �^ --- I � � � s� r� '`--�T �------_-r6�.� r,� o�
+�"C°�����';n '_�' DRAlNAGE EASEMEN7 �t� , p�� �.` 00 � 10' Ui7. '�-F45cMENT � I
v�l iz^�� ��--- "' .
� ,,� ' l�\r O (�'Y l�6� ..y1 n(C"i'� v l� ^ � r ^ ,��\ - � �01
�u9' 9' ��� ` � f�'10H.80 � '�� -� �'' � �e� .,.-+/
-- � ` �'� r�T 9 J g L � j'-� � � ��1£t "• - ,��_�� • 'V a,--�4� r� •
,' •� �� �e- P�A'D 106.1 .8 `� . ,1 � "1 _
'�8. �� a- �PE B 1� ' ____ .---'� 1 � � �1 � ' � � � 1O ,-' �•
T\\ m ` P;r '�-- T '� '1y
�. `1 `,.`?� }�1'611b, _- _-,_"'_ . . ` . � `� _��� 'I - ' `�
- �{CT✓ _• -' '
T m ` - `, _- 10� �uN _ - , \
1 � •VQ •. P - ,-'- - _�E�'�--+�
� ' 7'(88.8 - -- � FF=109_90
. �� ��,s • c FF'=109.QD _. LOT 1 � �
r ,�• PAD=109.2 `�
_ �I a�" r��Z �+�� PAL4��D8.3 / FF=1a9_20 � "-FF=110.16� 7YPE 8 `�
�,�. . FF=1 t 0.2Q � FF=110.50 ' LOT 2
� , �.\ 5� v ,�• ,<- � r�E�a... , LC�T 7 � �OT �t-v • LOT 5 � FF=11�.50 FF=110_3Q.- � p�=�os.a J'1 - -�-'
•s 6 PA�-108.5 -.PAD=r3,�8.5 PA�N¢918 LOT 4 LOT_•3"� 71'pE B c, 6- ' 3�
'��� � �STYPE B � g PAD-t Q9.8 PAD-=109.6 Gj� ;1� �
� „- , , �� �� � TYPE BJ�� TYPE B pC�-� "4�0 t` c
\ �� �g� �r ' '\�`7 I ` \ '� 107. �-
`rO�� T �O��r r �'s' ,r � __ - � - - ------ -- p,�'- _ p �� H
�e��� Y� �-� �0 C -�
� �� '" �y� ..= c I� . � � _ � � � � ',
� � -
o . . - .
'Y��s��2 i7��'. �-.u, .s• �r �O -` _�1� �'� r �O" ..F,�J 5 18'(87. . - - ;
a� � ��y �� �� �o ��_• i s�
'.� �� �� 'aE'. _ - " _ _ . T . __ ___ ' �' '_ __ � -�• ' � �
WETLAND �6:0������. �- _ - _ _ - ° � -
�.- � . r� -r �� C
��� �����, r , ' - " _ _ ���M�G4
� CONSERVATION ����.���- � „ .� . .� .�8. ��,Y� _ - � ���-�.�
�� � � �-� ���• _T /- .���°����-� . �
AREA P ���- � 6�� ,. � �,.,
�. „- , ,,. . R r �,-�,-g _ �Sy
�1,� ��' { - � � P� r T' ��3"��_ a;
. / ._. -- \ �6" .� --- p,J, T, � aN� P�� p�� a --�a -' �-'�=-�
� 1 .22) AC. �-� ��zQ ��` � � t� " �- �B 6. 6� �� �,._ o�_.Y�✓,T. ��
, '� �� ` •� • 9'B' Y% s r�r .� � �c-
_ ]OOYRDHW=104.0 __.__ __ . CONTROL SfRUCTUR�C Oew�s- � �O � � .' ' � .6 '/ �°r q,:;%��6-
, '- -• __' •.�.^ � y s'�a`' d i '�9s-
- ' .. _ --- � �,.,�""�'C � r,�yc
-- _ �s 2'�" ,Qe' � ." .'�lc �
�� _--;o
� ' C c'�T � tr � d�'
- - - ._ - � • - - -- o�. � S \e� - - - - - - ----- - - - . .-- --- - .
,_ ._.V. • -._ •. �""' [JV J! /1US�LG �Q� .__ \� _ __��"___'__ 'h~ _.
a - . . ,
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Perforrriance Method
Project Name: 2600B sf ADS Builder Name: LENNAR HOMES
street: 6527 Paden Wheel Street Permit o�tice: City of Zephyrhills
City,State,Zip: ,FL, Permit Number G�j,Z�
Owner• LENNAR HOMES Jurisdiction: 611600
Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2)
1 New construction or existing New(From Plans) 9. Wall Types(2400.6 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 2031.60 ft2
b.Frame-Wood,Adjacent R=11.0 369.00 ftz
3. Number of units,if multiple family 1 c.N/A R= ft'
4. Number of Bedrooms 4 d.N/A R= ftZ
5. Is this a worst case? � Yes 10.Ceiling Types (2599.0 sqft.) Insulation Area Z
a.Under Attic(Vented) R=30.0 2599.00 ft
6. Conditioned floor area above grade(ft2)' 2599 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft� ,
11 Ducts R ftz
7. Windows(300.2 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 519.8
a. U-Factor: Dbl,U=0.54 141.68 ftz
SHGC: SHGC=0.31
b. U-Factor Dbl,U=0.58 • 72.00 ft' 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 42.0 SEER:15.00
c. U-Factor: Dbl,U=0.56 48.00 ft'
SHGC: SHGC=0.32 13.Heating.systems kBtu/hr Efficiency
d. U-Factor other(see details) 38.50 ftz a.Electric Heat Pump 42.0 HSPF:8.50
SHGC: other(see details)
Area Weighted Average Overhang Depth: 5.520 ft.
Area Weighted Average SHGC: 0.310 14 Hot water systems
8. Floor Types (2599.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF 0.950
a.Slab-On-Grade Edge Insulation R=0.0 2599.00 ftZ b. Conservation features
b.N/A R= ftz None
c.N/A R= ftZ 15.Credits Pstat
Total Proposed Modified Loads: 82.41 pASS
Glass/Floor Area: 0 115
Total Baseline Loads: 82.65
�
I hereby certify that the plans and specifications covered by Review of the plans and ��'t?�ST.��.�
this calculation are in compliance with the Florida Energy specifications covered by this � , ,�� ��_�.� t7y,t,�
Code. , calculation indicates compliance �'�>r;,;'`r� �_='.•��„�. �
with the Florida Ener Code. �. Irr�r{�'%:`�:,;:_�:�'°�"'P,ti O.
/. 9Y � a��;,::s�.. �..
PREPARED BY: '�ave ����V` Before construction is completed �. •� ►�
�: �7.. �__. t'7
DATE. this building will be,inspected for Lry:g, i,,� � :
compliance with Section 553.908 *� '�
I hereby certify that this building,as designed, is in compliance Florida Statutes. t�,� � �����
.with the Florida Energy Code. D yyE�
,
OWNER/AGENT: BUILDING OFFICIAL.
DATE: � ` � DATE.
- Compliance requires certification y the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accord nce with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2. '
6/13/2017 1�19 PM EnergyGaugeOO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4
.� - � • . .
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 2600B sf ADS Builder Name: LENNAR HOMES
street: 6527 Paden Wheel Street Permit office: City of Zephyrhills
City,State,Zip. ,FL, Permit Number
Owner• LENNAR HOMES Jurisdiction: 611600
Design Location: FL,Tampa County Pasco(Florida Climate Zone 2)
1 New construction or existing New(From Plans) 9. Wall Types(2400.6 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 2031.60 ft2
b.Frame-Wood,Adjacent R=11.0 369.00 ftz
3. Number of units,if multiple family 1 c.N/A R= ft'
4 Number of Bedroams 4 d.N/A R= ft''
5. Is this a worst case? Yes �0.Ceiling Types (2599.0 sqft.) Insulation Area Z
a.UnderAttic(Vented) R=30.0 2599.00 ft
6. Conditioned floor area above grade(ftZ) 2599 b.N/A R= ftZ
Conditioned floor area below grade(ft') 0 c.N/A R= ftZ
11 Ducts R ft2
7. Windows(300.2 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 519.8
a. U-Factor: Dbl,U=0.54 141.68 ft�
SHGC: SHGC=0.31
b. U-Factor Dbl,U=0.58 72.00 ft�� 12•Cooling systems kBtu/hr E�ciency
SHGC: SHGC=0.32 a.Central Unit 42.0 SEER:15.00
c. U-Factor Dbl,U=0.56 48.00 ft�
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor• other(see details) 38.50 ftz a.Electric Heat Pump 42.0 HSPF:8.50
SHGC: other(see details)
Area Weighted Average Overhang Depth: 5.520 ft.
Area Weighted Average SHGC: 0.310 14 Hot water systems
a.Electric Cap:40 gallons
8. FloorTypes (2599.0 sqft.) Insulation Area EF 0.950
a.Slab-On-Grade Edge Insulation R=0.0 2599.00 ftz b. Conservation features
b.N/A R= ftZ None
c.N/A R= ft� 15.Credits Pstat
Glass/Floor Area: 0 115 Total Proposed Modified Loads. 82.41 pASS
Total Baseline Loads: 82.65 '
�
I hereby certify that the plans and specifications covered by Review of the plans and ��'�$�'<q�•.�
this calculation are in compliance with the Florida Energy specifications covered by this �M1r ,f � ��� {��,, .
Code. calculation indicates compliance v}'��,,,��'�? -' ;�ry�
!� :rtrirrt`�';,,'o;,::a4r�`+X. ti O.
�ave �Gal�rcl� �✓ith the Florida Energy Code. �, . �„"�,�,,,, �
PREPARED BY' Before construction is completed •w �
� ���;�.�. cs
DATE: this building will be inspected for Lry ��ry;��:�t. . �
compliance with Section 553.908 .��"�
I hereby certify that this building,as designed, is in compliance Florida Statutes. �',�, ; � ���.µ
with the Florida Energy Code. ��I�y1'fi`�'
.
OWNER/AGENT. BUILDING O FICIAL:
DATE: DATE: '
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as -
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
6/13/2017 1•19 PM EnergyGaugeOO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4
. �
d t ,
FORM R4C15-2014
f
FLORIDA ENERGY EFFICIENCY CODE FOR BUlLDING Cl'�NSTRUCTION
Flarida Department of Business and Professianal Regu(ation - Residential Performance Methad
Project Name: 2600B sf ADS Builder Name: LENNAR HOMES
street: 6527 Paden Wheel Street Perm�t ot�ice: City of Zephyrhills
Gity,State,Zip: ,FL, Permit Number
Owner LENNAR HdMES Jurisdiction: 61 J.600
Design Location: FL,Tampa County� Pasca{Florida Ctimate Zone 2}
1, New construction or existing New{From Plans) 9. Wall Types(2A00.6 sqft.) Insulation Area
2. Singie famiiy or mulfiple famiiy Single-family a.Concreta Block-Int Insui,Exterior R=4 1 2031.6d ft2
b.Frame-Wood,Adjacent R=11.0 369.00 ft2
3. Number of units,if multiple family 1 c.N/A z
R= ft
4 Number of Bedraoms q d.NtA R= ft'
5. Is this a worst case? Yes 10.Ceiling Types (2599.0 sqft.) Insulatian Area
a.Under Attic{Vented) R=30.� 2599.00 ft'
6. Conditianed floar area above grade{ftz} 2589 b.NtA R= ftZ
Conditioned floor area below grade(ft2) 0 c.N/A R= ft'
11.Ducts R ft2
T Windows(30Q.2 sqft.) Description Area a.Sup:Attic,Ret:Ntain,AH:Main 8 519,8
a. U-Factor• Dbl,U=0.54 141.68 ft2
SHGG: SHGC=Q.31
b. U-Factor Dbl,U=0.58 72.00 ff2 '12.CoaIing systems kBtuthr Efficiency
SHGC: SHGC=0.32 a.Central Unit 42.0 SEER:I5.OQ
c. U-Factor DI�I,U=0.56 48A0 ftZ
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor other(see details) 38.50 ft2 a.Electric Heat Fump 42.0 HSPF:8.50
SHGC: other(see details}
Area Weighted Average Overhang Depth: 5.520 ft.
Area Weighted Average SHGC: p.3�p 94 Hot water systems
8, Floor Types (2599.0 sqft.) Insulation Area � a.Eiectric Cap:4Q gallons
a.Slab-On-Grade Ed e Insulation R=0.0 2599.00 ftz EF•0.950
9 b. Canservatian features
�b.NIA �_ �2 None
c.N/A R= ft� 15.Credits Pstat
Totai Proposed Modified Loacis: 52.41 � p ��
Glass/Floor Area: 0.115 h
Total Baseline Loads: 82.65
I hereby certify that the pians and specificafions cavered by Revisw of the pians and `�',£��T,q
this calculafion are in compiiance with#he Florida Energy specifications covered by this ti+� . `�, �;�t�
Gode.� calculation indicates compliance ��rr,�l''F'` `;=.�,,,�.�+�t:
��v� �J J��j, wi t h t he F lori da Energy Co de. ` +�. .nrrs�`-`'{`.`;:_:°.:�`�, �C 2
PREPAFtED BY: W< <'Z Before construction is completed :� : ���'J:`'N Q
DATE: this building will be inspected for �.��„r��(:-: " :�= .
compiiance wi#h Secfian 553.948 �• �'� : .�.
I hereby certify that this building,as designed, is in compliance Florida Statutes. ,r,�,; ��,
with the Flarida Energy Code. '�'4L?y�`��
OWNER/AGENT: BUILDING OF CIAL:
DATE: ' DATE. '' ''
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure quatifies as - �
certifted factory-sealed in accardance wifh Rd03.2.2.4. �
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test repoct in accardance with R402.4.1.2.
6/13/2017 1•19 PM EnergyGaugeC�USA-FlaRes2014 Section R40S.4.1 Compliant Soflware Page 1 of 4
d ti � . �
FORM R405-2014
PROJECT
Title: 2600B sf ADS Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 2599 Lot#
Owner LENNAR HOMES Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: LENNAR HOMES Rotate Angle: 45 Street:
Permit Office. Cross Ventilation: No County� Pasco
Jurisdiction: Whole House Fan: No City,State,Zip:
', Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Blocki 2599 24170.7
SPACES ' '
Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated
1 Main 2599 24170.7 Yes 5 4 1 Yes Yes " Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 249 ft 0 2599 ft' ___ 0.3 0 0.7
ROOF
� Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor Tested Tested Insul. (deg)
1 Hip � Composition shingles 2907 ft2 0 ftZ Medium 0.85 No 0.9 No 0 26.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic � Vented 300 2599 ftz N N
CEILING �
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main - 30 Blown 2599 ft2 0.1 Wood I
6/13/2017 1:19 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Sofiware Page 2 of 4 I
1
� ` 1 . �
FORM R405-2014
WALLS
Adjacent SPa� Cavity Width Height Sheathing Framing Solar Belo w
1 N=>NE Exterior Concrete Block-Int Insul Main 4 1 15 4 9 4 143.1 ftz 0 0 0.6 0
2 S=>SW Exterior Concrete Block-Int Insul Main 4.1 32 0 9 4 298.7 ftZ 0 0 0.6 0
3 E=>SE Exterior Concrete Block-Int Insul Main 4 1 68 9 4 634.7 ftZ 0 0.6 0
4 W=>NW Exterior Concrete Block-Int Insul Main 4 1 66 9 4 616.0 ft' 0 0.6 0
_5 N=>NE Garage Frame-Wood Main 11 28 9 4 261.3 ft2 0.23 0.01 0
_6 W=>NW Garage Frame-Wood Main 11 9 6 11 4 107.7 ft' 0.23 0.01 0
7 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 5 4 11 4 60.4 ft� 0 0.600000 0
8 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 18 11 4 204.0 ft' 0 0.600000 0
9 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 8 9 4 74.7 ft2 0 0.600000 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>NE Insulated Main None 2 3 6 8 20 ft�
2 N=>NE Wood Main None 4 2 8 6 8 17.8 ft� _
WINDOWS
Orientation shown is the entered orientation(_>)chan ed to Worst Case.
/ Wall Overhang
�� # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5
2 S=>SW 8 Metal Low-E Double Yes 0.58 � 0.32 72.0 ft� S ft 0 in 0 ft 2 in Drapes/blinds None
3 E=>SE 3 Metal Low-E Double Yes 0.54 0.31 64.0 ft= 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5
4 W=>NW 4 Metal Low-E Double Yes 0.54 0.31 16.0 ft' 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5
5 E=>SE 9 Metal Low-E Double Yes 0.56 0.32 48.0 ft2 18 ft 0 in 0 ft 2 in Drapes/blinds None
6 S=>SW 2 Metal Low-E Double Yes 0.54 0.31 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5
7 S=>SW 2 Metal Low-E Double Yes 0.54 0.31 23.0 ftZ 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5
8 N=>NE 7 Metal Low-E Double Yes 0.56 0.28 6.5 ft' 6 ft 8 in 3 ft 0 in Drapes/blinds Exterior 5
9 W=>NW 4 Metal Low-E Double Yes 0.54 0.31 6.7 ft' 1 ft 0 in 0 ft 10 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 589 ft' 589 ftZ 60.8 ft 9.3 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EqLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000295 2014.2 110.58 207.96 .2216 5
6/13/2017 1:19 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Sofiware Page 3 of 4
a � • .
FORM R405-2014
HEATING SYSTEM �
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump None � HSPF:8.5 42 kBtulhr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER:15 42 kBtu/hr 1260 cfm 0.85 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 60 gal 120 deg None
SOLAR HOT WATER SYSTEM '
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None � ft'
DUCTS
/ —Supply— —Retum— Air CFM 25 CFM25 HVAC#
V # Location, R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 519.8 ft Main 130 ftZ Default Leakage Main (Default) (Default) 1 1 '
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Coolin Jan Feb Mar A r Ma X Jun [X]Jul Au [X Se Oct Nov Dec
Venting �Jan �Feb �X�Mar �X�Apr � �May � ��un E ]Jul ��Aug E �Sep ��Oct X�Nov €�Dec
Jun ]Jul Aug Sep
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(1ND) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(VVD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(1NEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MECHANICAL VENTILATION
Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System
None 0 0 0 1 -Electric Heat Pump 0% 1-Central Unit
6/13/2017 1�19 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compiiant Software Page 4 of 4
� � • .
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE �INDEX* = 100
The lower the EnergyPerformance Index, the more e�cient the home.
. , , FL,
1 New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 2031.60 ftZ
b.Frame-Wood,Adjacent R=11.0 369.00 ft
3. Number of units,if multiple family 1 c.N/A R= ftZ
4 Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2599.00 ftZ
6. Conditioned floor area(ft� 2599 b.N/A R= ftz
7 Windows** Description Area c.N/A R= ft�Z
a. U-Factor Dbl,U=0.54 141.68 ft' �1 Ducts R , ft
a.Sup:Attic,Ret:Main,AH:Main 6 519.8
SHGC: SHGC=0.31
b. U-Factor Dbl,U=0.58 72.00 ft'
SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency
c. U-Factor• Dbl,U=0.56 48.00 ft' a.Central Unit 42.0 SEER:15.00
SHGC: SHGC=0.32
d. U-Factor other(see details) 38.50 ft' �3.Heating systems kBtu/hr Efficiency
SHGC: other(see details) a.Electric Heat Pump 42.0 HSPF:8.50
Area Weighted Average Overhang Depth. 5.520 ft.
Area Weighted Average SHGC: 0.310
8. Floor Types Insulation Area 14 Hot water systems
z a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 2599.00 ft EF 0.95
b.N/A R= ftZ
c.N/A � R= ft� b. Conservation features
None �
15.Credits Pstat �
I certify that this home has complied with the Florida Energy Efficiency Code for Building �;��Es�.�r
Construction through the above energy saving features which will be installed (or exceeded) , ,�;o _. Fo . -
in this home before final inspection. Otherwise, a new EPL Display Card will be completed �W�'r�j,�l,,:=`.=.;,..;�,,
based on installed Code compliant features. � rer���'�-�„.:;r;=:,°;.:�„o
..: - �
� .:af k� . = �7
Builder Signature. Date: 06/13/17 � ���x5' " �
* �.g
Address of New Home. 6527 Paden eel Street City/FL Zip� Zephyrhills,FL 33541 "�?� �j�s� .
ob,H,�� .
'`Note: This is not a Building ergy Rating. If your Index is below 70, your home may qualify for energy e�cient
mortgage (EEI1il) incentives if ou obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the Energy auge web site at energygauge.com for information and a list of certified Raters. For
, information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of.the Florida Building Code, Energy Conservation, if not DEFAULT.
6/13/2017 1:21 PM EnergyGauge�USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
J
, , . , ,
Buildin Anal S�S Jo6: 2600BsfADS
g y Date: 6/13/2017
Entire House By: Dave
Bayonet Plumbing Heating and Air -
� • - s m
For: Lennar Homes
i& - • • e o
Location: , Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD (�F) 39 16
Latitude: 28°N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7
Dry bulb(°F) 31 91 Infiltration:
Daily range(°F) - 14 ( L ) Method Simplified
Wet bulb(°F) - 77 Construction quality Semi-tight
Wind speed (mph) 15.0 7 5 Fireplaces 0
0
Component Btuh/ft2 Btuh % of load .
Walls 5.6 9884 25.2 0���
Glazing 30.2 9215 23.5 waii
Doo�s 23.5 480 1.2 Infiltration
Ceilings 1.3 3260 8.3 �
Floors 3.2 8238 21.0
Infiltration 1.9 4052 10.3
D ucts 4153 10.6 • Fioo�s
Piping 0 0
Humidification 0 0 Glazing
Ventilation 0 0 Other Ceilings
Adjustments 0
Total 39282 100.0 `
- m • e
Component Btuh/ftZ Btuh % of load
Walls 2.8 4917 14.7 walls Intemal Gains
Glazing 47 5 14491 43.2
Doors 18.4 376 1.1
Ceilings 17 4507 13.4 oucts
Floors 0 0 0 ;' � , .
Inftltration 0.4 843 2.5 ! Infiltration
D ucts 4631 13.8
Ventilation 0 0
Internal gains 3750 11.2 Ceilings
Bloviwer 0 0 Glazing
Adjustments 0 otner
Total 33514 100.0
Latent Cooling Load= 3601 Btuh
Overall U-value= 0.109 Btuh/ftZ-�F
Data entries checked.
�
-�- -�- wrightsoft` 2017-Jun-73 13:32:40
vr'�- Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1
'� �.th CBA27UHE AH's\2600B sf ADS drawn 3.5 ton.rup Calc=MJ8 Front Door faces: N
— J
. • • .
Pro ect Summa , �ob: 2soos Sf aos
1 � Date: 6/13l2017
En tire Ho use By: Dave
_ . Bayonet Plumbing Heating and Air
' o - s •
For� Lennar Homes
�
N otes.
� - • e •
Weather: Tampa International AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 °F Outside db 91 °F
Inside db 70 °F Inside db 75 °F
Design TD 39 °F � Design TD 16 °F
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 35129 Btuh Structure 28883 Btuh
Ducts 4153 Btuh Ducts 4631 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Hum�id f c�ation 0 Btuh BI wer e� 0 Btuh
Piping 0 Btuh f
Equipment load 39282 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 33514 Btuh
Method simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 2748 Btuh
Ducts 853 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft2) 2599 2599 Equipment latent load 3601 Btuh
Volume(ft') 25640 25640
Air changes/hour 0.22 0.11 Equipment Total Load (Sen+Lat) 37115 Btuh
Equiv.AVF(cfm) 94 47 Req. total capacity at 0.85 SHR 3.3 ton
Heating Equipment Summary Cooling Equipment Summary
Make Lennox Make Lennox
Trade 14HPX SERIES Trade 14HPX SERIES
Model 14HPX-042-230-21 Cond 14HPX-042-230-21
AHRI ref 10258591 Coil CBA27UHE-042-230*++TDR
AHRI ref 10258591
Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER
Heating input Sensible cooling 36975 Btuh
Heating output 43500 Btuh @ 47°F Latent cooling 6525 Btuh
Temperature rise 28 °F Total cooling 43500 Btuh
Actual air flow 1400 cfm Actual air flow 1400 cfm
' Air flow factor 0.036 cfm/Btuh1 Air flow factor 0.042 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.90
Capacity balance point=29°F
Backup: n/a Na
Input= 0 kW, Output= 0 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
i� � Wf 1 �'1tS0'� 2017-Jun-13 13:32:40 � _
g Right-Sufte�Universal 2017 17.0.23 RSU05714 Page 1
�� .th CBA27UHE AH's\26008 sf ADS drawn 3.5 ton.rup Calc=MJS Front Door faces: N I
J
i r ._ ._ �I
. Manual S Compliance Report Job: 2600BsfADS
Date: 6113/2017
Enfire House By: Dave -
� Bayonet Plumbing Heating and Air
' s - • •
For: Lennar Homes .
• • • • e
Design Conditions
Outdoor design DB. 91.3°F Sensible gain: 33514 Btuh Entering coil DB 75.6�F
Outdoor design WB: 77 3°F Latent gain: 3601 Btuh Entering coil WB. 62.8°F
Indoor design DB: 75.0°F Total gain: 37115 Btuh
Indoor RH. 50% Estimated airflow: 1400 cfm
Manufacturer's Performance Data atActual Design Conditions
Equipmenttype: SpIitASHP
Manufacturer: Lennox Model: 14HPX-042-230-21+CBA27UHE-042-230*++TDR
Actual airtlow: 1400 cfm
Sensible capacity: 35700 Btuh 107% of load
Latent capacity� 6300 Btuh 175% of load
Total capacity: 42000 Btuh 113% of load SHR. 85%
• e •
Design Conditions
Outdoor design DB. 30.8°F Heat loss: 39282 Btuh Entering coil DB� 69.7°F
Indoor design DB� 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Lennox Model: 14HPX-042-230-21+CBA27UHE-042-230*++TDR
Actual airflow: 1400 cfm �
Output capacity: 42000 Btuh 107% of load Capacity balance: 29 °F
Supplemental heat required: 0 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip .
Manufacturer n/a Model: n/a+n/a
Actual airflow: 1400 cfm
Output capacity� 0 kW 0% of load _ Temp. rise: 0 °F
Meets are all requirements of ACCA Manual S.
,� wri htsoft'� 2017-Jun-1313:32:40
��� 9 Right-SuRe�1 Universal 2017 17.0.23 RSU05714 Page 1
.th CBA27UHE AH's12600B sf ADS drawn 3.5 ton.rup Calc=MJS Front Door faces: N
^ e
, .. � � . : ,.' P/�$�'.�C.�UNN
' ., . ._. r_� :, ; BUILDIPIG CONSYRUCTIOfd SERVICES
y�~� ` � � 8731 Citizens Drive Date: 11/14/2017 �
J
-- Sufte 230
� �� New Port Richey, FL 34654
� . � ' ` '' ' 727-847-8127
*�r �� 1 � �!�.�1 V 1 � 1 �'c'y�'
Receipt#: 1719181
FEE DESCRIPTION ACCOUNT CODE UIdIT$ INV�# FEE AMOUNT PAID RECEIPT# DATE
Impact Fee Residential Solid 24503100-329010 10.03 1299255 $10.03 $10.03 1719181 11/14/17
Waste Single Family
ZHILLS 50LID WASTE.
TOTALS: $10.03 $10.03
Receiot# Paid Bv Check# CC Auth# Cashier ID Workstation Recefpt Date Amt Paid
1719181 Check 20303 294 BCCBISCAN02W 11/14/2017 $10.03
Total Payments: $10.03
Pavor Address. Phone
LFNNAR HOMES 6527 PADEN WHEEL ST 8133632891
Comments•
ZHILLS SOLID WASTE
6527 PADEN WHEEL ST
0526210070004000060
P#18700
- - - -- ; - — ,---� - — - -
�
02895856 Lennar Homes,LLC JPMorgan Chase Bank N,A. - STUB CHECK NO. 920303
INVo�CE 900000.1010.114 1 of l DA TE 11/02/1?
.
CO.# IVUMBER DATE � PAYMENT�IDV/CE GROSS DISCOUNT NET
! 15225, 15225710406.401435 102517� 15225710406 401435 ^ 510.03 $0.00 $10.03
� . , ,
� �
. �
�� �
, � � '
i �
i , �
+ �O �
i f�C ~ r
' �1 � ��.�� �
' � � ��� ,
1971597 Pasw County BOCC 7530 Littic Roa `, �