HomeMy WebLinkAbout17-18786 I
CITY OF ZEPHYRHILLS
5335-8TH STREET �''����
(813)780-0020 � � $/ 6 �
. - f �
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
i
I, '
� -- PERMIT INFORMATION -> LOCATION.INFORMATION -
Permit#:18786 Issued: 8/29/2017 Address: 6503 PADEN WHEEL ST
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. ;
Class of Work: 101-NEW CONST/SFR Township: Range: �
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 420,866.52 Total Fees: 12,087.69 Subdivision: SILVERADO ;
Amount Paid: 12,087.69 Date Paid: 8/29/2017 Parcel Number: 05-26-21-0070-00400-0040
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 15550 LIGHTWAVE DR Address: 4600 W CYPRESS ST STE 200 �
CLEARWATER, FL. 33760 TAMPA, FL. 33607-4099
Phone: (727)479-1740 Lic: Phone: (813)574-5700
Work Desc: CONSTRUCT SINGLE FAMILY 3,957 SQ FT
APPLICATION FEES
BUILDING FEE 1,560.01 ELECTRICAL FEE 326.48 PLUMBING FEE 217.65
MECHANICAL FEE 152.36 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00
� SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
1 1 \� ,
� �
����� -�- -� � ;
��������
l
Ins ections Re uired
FO TER 2ND ROUGH PLUMB MIS INSULATION CEILING '
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY ,
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
� REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection o'r
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this properly that
� may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for;
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney,
before recording your notice of commencement." �
Complete Plans,Specifications and Must Accompany Application.All work shall be pertormed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. ,
- NO OCCUPANCY BEFORE C.O.
�� �-��o I
CONTRACTORS SI NATURE PERMIT OFFI
PERMIT E CPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CA L FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
i -�
CITY OF / / / / BUILDINGI
ZEPHYRHILL�3 f DEPARTMENT
OF ADDITION OR CORRECTION
� • • - • �
�
� �
ADDRESS ' DATE PERMIT,f _
v � l��v-» �
THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before th �job
will be accepted. �
(
� , i�',�', ��a�1 Cr`�� ,�i7�f i�l' dv� �
_��0��ov�,� 'f�(S�'t��-
I
i
j
It is unlawFul tor any Carpenter,Cantractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL
cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-INSPECTION
or other material,until the proper inspector has had ample Gme to approve
the installation.
OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR
a�a-�so-oozo City of Zephyrhills Permit Application Fax-813-780-0021
, � . B�ilding Department ,
�., 'J ,.'.a.�+
Date Received �l � 813 • 363 _ 2891
Phone Contact for Permittin
1-1—r
Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700
Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number
Fee Simple Titleholder Name N�A � Owner Phone Number �
Fee Simple Titieholder Address N�A I
�
JOB ADDRESS 6503 Pacien Wheel Street LOT# 0040 ,
SUBDIVISION Silverado Ranch Subdivision Ph 2,3,84 pARCEL ID# 05-26-21-0070-00400-0040 ,
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED II✓ II NEW CONSTR e ADD/ALT 0 SIGN � � DEMOLISH
� INSTALL REPAIR
PROPOSED USE � SFR Q COMM 0 OTHER
TYPE OF CONSTRUCTION � BLOCK Q FRAME 0 STEEL 0
DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence
BUILDING SIZE U/R SF 3g57 SQ FOOTAGE 3�27 HEIGHT 2 StOry
-r�� r-�-�-r- 1-r�rrrrrm-rrrrr- �-
✓ BUILDING $ ��1 VALUATION OF TOTAL CONSTRUCTION
7 Uu
I�/ 'ELECTRICAL $ � PROGRESSENERGY 0 W.R.E.0
' � ` AMP SERVICE
�PLUMBING $ �r � Z��
�MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
OGAS � ROOFING Q SPECIALTY 0 OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA �YES �O ;
u
I -�--E-4-1-1-a-��--��F-F-1--1-�1-H�:-r:-r�4-1-�1-1-a-1--1�-4-1�1-�i--1-�F-1-i--0-�--�1--��1--F-�4-��1-�F-'-:-'-:TTr-:--F-�.- ,
� BUILDER COMPANY Lennar Homes,LLC
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
� Address 4600 W.Cypress St.Ste.200, ampa,FL 33607 License# CGC151S166
�
ELECTRICIAN COMPANY Edmonson Electric, Inc. '
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N �
Address 1034 Skipper Road,Tampa, L 33613 �icense# EC13005408
PLUMBER COMPANY Bayonet Plumbing, Heating & AC, Inc ,
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address P.O. Box 5308, Bayonet, FL 4674-5308 License# CFC042998
MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address P.O. Box 5308, Bayonet, FL 34674-5308 �icense# CAC058062
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
,4adress 4211 Shoal Line Blvd, Sprin Hill, FL 34607 �icense# CCC057991 �
� � � � � � � t � � � � � � � � � � � � � i � � � � � t � � �-� � � � � � � � � � � � � � � � � t � � � � � � � � � � � � � � � � � � I
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for'new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
"'*`PROPERTY SURVEY required for all NEW construction.
-i-�1..�1-.�.�..1..1..4.' '...r.�...�' 1..1-i-1..�5��' :..�.I..�I..f-�I..I.�i�1..�1..1..4.f-I..�I..f-I..I..i�l..��f..1..4�1..�1..1-1..1..1-�1..�1..1..1�1-
Directions:
Fill out application completely
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
`* Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required) ,
Reroofs if shingles Sewers Service Upgrades A/C Fences(PIoUSurvey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
, , , ,
NOTICE OF DEED RE$TRICTIONS�' The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the -
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009 Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATIOfd IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of ne�buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting It is further understood that Transportation Impact Fees and,Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended) If valuation of work is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner"prior to commsncement.
CONTRACTOR'S/OWNER'S AFFIDAVIT� I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be. performed to meet standards of all laws regulating ,
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to �
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive i
Lands,Water/Wastewater Treatment. ii
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering �
Watercourses. ,
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. I
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone"V" unless expressly permitted. � ,
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida. ,.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
I - If fill material is to be used in any area, I certify that use of such.fill will not adversely affect adjacent I
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
� acre which are elevated by fill, an engineered drainage plan is required. i
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, !
plumbing, signs, wells, pools,, air conditioning, gas, or other installations not specifically included in the application A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter ,
requiring a correction of errors in plans, construction or�violations of any codes Every permit issued shall become invalid �
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension If work ceases for ninety (90) consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR '
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S.117 03)
OWNER OR AGENT CONTRACTOR
Subscribed and sworn to(or affirmed)bef e me this Subscribed and sworn to(or a�rmed)befo me this
uu-�un-i i by paul Sweene oB-���-,� by Paul Sweene
Who is/are personally known to me or� sJka�de-pra�sed Who is/are personally known to me or• ��red�eed
as id ntification. � ntification.
�
Notary Public Notary Public
Commission No. FF98537 Commission F98537 -
Elissa M.Holleran Elissa M.Holleran
Name of Notarv tvped,printed or stamped Name of Notary typed,printed or stamped
w..��.�..,rt
_
r. �w'�"��'' �'�. �, �����.��.@IOI,I��
������r�t���{�,���p�}�^� „ 4 CAlf,tii�#."Oflif�fR9�'l���
L ��'�d�l4nE��{•Q���i ,§ �1
p•' ` .��Jl��i�}lll�'�'��t��tl
[�b.���sur�;�'���� '� �.4��E,r:���+gn��a��fo
,. r' �iid'61r�T-ery��t�!et��ts�,tl5��kll
� iiviiiiiiiiiiiiiiiiiiiissiiiiiiiiiiiiiiiiiiiiii.iiiiiiiiiiiii - l ��,.,,,,�
' 2017133261
, � � , , � Rcpt:1889287 Rec: 10.00 . �
� DS: 0.00 IT: 0.00
' - • 08/22/2017 J. G. , Dpty Clerk � ,
PRULR S 0'NEIL�Ph D PASCO CLERK & COMPTROLLER
i,08/R BK 17 03:2�m P� i i�2_ ,
, , 0 95J
PermitNo. ' ParceIlD,No 05-26-21-0070-00400-0040
- NOTICE OF COMMENCEMENT
State of FlOflda County of Pasco �
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chepter 713,Florida Statutes;
the following information is provided in this Notice of Commencement: ,
1. Description of Property: Legal SILVERADO RANCH SUBDIVISION PHASES 2,3,&4 PB 73 PG 59 BLOCK 04 LOT 04 . .
st�eet Add�eSs: 6503 Paden Wheel Street Zephryhills FL 33541
2. General Description of Improvement Single�Family Residence/Pool/$creen Enclosure/Fence ' �
i
3. Owner Information: Lennar Homes, LLC j ; '
Name ,
4600 W Cxpress St. Ste 200 Tampa FL. 33607
Address City State '
, Interest�in Property• �
Name of Fee Simple Titleholder: N�/4 ;
(If other than owner) � �•
Address City State
' 4 contractor Lennar Homes, LLC ' '
Name �
„ 4600 VV Cypress St, Ste 200 ' Tampa FL, 33607
Address j City State
- � Contractor's Telephone No 813 574 5700
. i
e � Surety� ' ''�" N/A -
Name '
Address City State
Amount of Bond. $ � Telephone No.. , ,
' 6. Lender; N�/�
Name • �
Address � . City State
Lender's Telephone No.. I
7. Persons within the State of Florida designated by the.owner upon whom notices or other documents may be served as provided by � I,
Section 713.13(1)(a)(7),Florida Statutes:
• Lennar Homes. LLC i -
' Name , ',
4600 VV Cvpress St, Ste 200 Tampa FI_, 33607 ��
- . Address City State � ' '
Telephone Number of Designated Person: 813.574 5700 ,
8. In addition to himself,the owner designates N/A of �
� to receive a.copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. �
Telephone Number of Person or Entity Designated by Owner• '
9 Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified:
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU.INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT
STATE OF FLORIDA �� ,' ,
COUNTY OF PINELLAS � / �
Signature of Owner or Owner's Authorized Officer/Director/PartnedManager
Vice President -
, Signatory's Title/Office
The foregoing instrumenf was acknowledged before me this $ day of MarCh ,�6�,by _ _ __
Steve Robert Smith as Vice Pfesident (type of authorit er,trustee,attorney in fact)for
Lennar H_omes, LLC (n e_of part n beh # om instrument was executed)
Personally Known■OR Produced Identification❑ Notary Si ture
i Type of Identificetion Produced . Name(Print) �ISS olleran
Verification pursuant to Section 92:525, Florida Statutes: Under perialties of perjury, I declare that I have Pead the foregoing and that the facts stated in
it are true to the.best of my knowledge'and belief. ; � ;
L��� ,,,, �
�,� ELISSNM.NOLI.ERAN SfgrtSfure of Natu`ral Person Signing Above -
;�..=C�mmlulon�FF 88583T
;,;,�o�=Ex'Iree June 6,2020
wpdata/bcs/bcsform: �f`�`'� DenddThruTroyFalnlMunna100�15-7ptp
��������� �
• ,.� ,� ,
� , t � �c
� , I���Q..�e�s ;: �,, � � �TATE OF FLORiDA,C�UN'TY��PASCO
� �'� ..��; r��," -�i THIS IS TO'CERTIFY THAT THE FOREGOING IS A
.• TRUE AND CORRECT COPY OF THE DOCUMENT
�" �88� � "_ �` •�•� ON FILE OR OF PUBLIC RECORD IN THIS OFFICE
�`�c , • z�, W�NESS MY HAND D OFFICIAC S AL THIS
" Repp � �—DAY OF 2��
PAU S O'NEIL` LERK& OMPTROLLER
Y � TY CLERK '
_ - �
�— _ , — { `��
� �
- ' �
B , �� .� � �
. ' " _j�����.`r`2;'".r, Y�;V �
?>..- 7
_ �:,,��, _ :;, �,�;,,,i; i
�.,r��r��..s' �.�.''�� I
.+�,,.�.. ,
City of Zephyrhills
BUILDING PLAN REVIEW CQIvIMENTS a
ContractorlHomeowner: L�,n� �
Date Received: � f�— � �
sixe: .� Y �-G{-Gr� �,{�k`���T`
Permit Type: ��� I�.' r` � � Z� � �� �
� �
Appraved wlno comments:❑ Approved withe beiaw comments: �� Denied w/the below camments: ❑
_ '�L � �1��i--� � �,
�
i I
_ �
� 1
I
This comment sheet sha11 be kept with the permit andlor plans. J
�
1 �--�''�� 7-z.�� 7 _
Kalvin Switzer— ans Examiner Date Contractor dtar Homeowner
{Required when camrnents are present} , ;
� ,
i
I
�
P�SCO C�IJI��'lf', �FL�RIDA
Permit No. ���_
Date Permitted ��--�� �
Builder Name/Owner Name �.x°�(�t�C��� j� Control#~ I,
County Parcel No, �S�?�?l p��� ������(�� SubDiv: �1 ,U I
AddresslLocation �C.sp� ���� �f�,e,� ;
Classificatlon/Type of Use �'j`y� l
TRANSPORTATION IMPACT FE � Rate: '
Sq.Ft Unit: 3, �� �
Exempt � Yes �] No How Determined `— �
� Impact Fee Amount $.3i(�3 y , Zone No. �
__ TAZ:
SCHOOL IMPACT FEE ,
Account (056) Single-Family Detached House Amount $ �,
(057) Mobile Home �76• �
(058) Other Resldential
123) Collection Fee
Exempt Yes � No How Determfned
PARKS AND RECREATION FEE
Land Account Land Credit
Land Total
Recreation Account Recreation Credit
___ Recreation Total
Zone TOTAL AMOUNT
$ 7�p�,6
Exempt � Yes � No How Determfned �
LIBRqRY FEE �
Land Account �
Land Credit Land Totai i
Facility Account �_ Facility Credit � �
Facility Total j
Exem t �
P ❑ Yes � No How Determined __ Total Amount � '
RESOURCE FEE
TOTALAMOUNT ERU i
Prepared By Checked By �
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION '
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
RECEIPTED FOR BY A CENT A�LEP RMITI'NG OFFICE OF PASCO COUNTY �
I
�
Acknowledgement below does not Imply acceptance of concurrence,but simply recelpt of a copy of this form,placing '
the building permft owner on notice of thls assessment and tha co�ditlons of payment for same.
I
,
DATE �
RECEIVED BY '
RECEIPT NO. __ pATE
_____ BY
Lennar Homes-6503 Paden Wheel_St-3,957 sq ft �
o umn � _ '
SQ. FEET• ; PRICE I
MAIN OR LIVING: 3,957 $ 106.36 i
I �
OTHER AREA UNDER ROOF: �- $ 88.00
OTHER: - $ -
VALUATION $ 420,866.52
FEE SHEET $ 1,451.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,560.02
ELECTRICAL: $ 326.48
PLUMBING: $ 217.65
MECHANICAL: $ 152.36
SUB-TOTAL $ 2,256.50
TOTAL $ 2,256.50
SEWER: n/a
WATER: n/a
IRRIGATION: $ -
TOTAL: $ -
WATER METER: n/a '
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a '
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES �
POLICE $ 254.00
FIRE $ 273.00 i
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 2,809.85
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00 ,
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00 �
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 12,087.69
i
�
6503 Paden Wheel I
o umn �
SQ. FEET PRICE I
UNDER ROOF: 3,957 $ 106.36 �
OTHER: - $ _
VALUATION $ 420,866.52 �
FEE SHEET $ 1,451.00 �
ADDRESS $ 40.00 I
�
DRIVEWAY $ 40.00 i
�
BUILDING: $ 1,560.02 I
ELECTRICAL: $ 326.48
PLUMBING: $ 217.65 i
MECHANICAL: $ 152.36
SUB-TOTAL $ 2,256.50 '
TOTAL $ 2,256.50 �
SEWER: �
WATER: j
IRRIGATION: $ - '
TOTAL: $ _
WATER METER:
IRRIGATION METER
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ .
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00 �
5% $ 26.35
TOTAL: $ 553.35 �
SUB-TOTAL $ 2,809.85 I
I
PARK IMPACT FEES $ 769.56 �
SIF'S: $ 4,828.00 �
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28 '
T I F'S: $ 3,632.00 �
99% $ 3,595.68 �
1% $ 36.32 ,
TOTAL: $ 12,087.69
i
Single Family Dwelling ;
Plan Review Comments
1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan.
2. Lots shall be graded to comply with R401.3 of the F.B.C. �
3. Compaction test required if 24" or more of fill dirt is brought in at any one place.
4. Tie in survey required before pouring concrete.
5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have
expansion material.
6. All setbacks shall be met. '
7. All property markers shall be uncovered and marked at time of first inspection.
8. All A.D.A. requirements shall be met. �
9. No electric, plumbing, mechanical, or framing shall be covered without an inspection and '
approval first.
10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).
11. Appliances shall not be installed in a location where subject to mechanical damage unless '
protected by approved barriers. M303.4 of the F.B.0 .
12. Water heaters shall comply with section P607.3 of the F.B.C.
13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1
14. Return air in all bedrooms. F.B.C. M1620.4
15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C.
16. All glazing requirements are to be in accordance with R308.4 of the F.B.C.
17. All means of egress are to be in accordance with R311 of the F.B.C.
18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C.
19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker.
20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating '
or appliances or an attached garage. They shall be installed in accordance with the F.B.C. �
21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all �
underground plumbing and electric. '
22. A112008 N.E.C. Codes will be enforced. !
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 �
22. In accordance with the Land Development Code, lots shall be sodded before final at least 10 '
feet around the structure. !
I
F.F.E.-Finished Floor Elevation
F.B.C- Florida Building Code Sth Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008)
,
I
i
OS-26-21-0070-00400-0040 � Pasco County Property Appraiser Page 1 of 1 I
�
. , I
Data Current as Of: Weekly Archive - Saturday, August 19, 2017 �
Parcel ID 05-26-21-0070-00400-0040 (Card: 001 of 001) i
Classification 00 - Vacant Residential I
Mailing Address Property Value i
LENNAR HOMES LLC Ag Land $0 ,
4600 W CYPRESS ST STE 200 Land $26,950 �
TAMPA FL 33607-4099 Building $0 '
Physical Address Extra Features $0 �
6503 PADEN WHEEL ST �
ZEPHYRHILLS, FL 33541
7ust Value $26,950
Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $26,950 �
SILVERADO RANCH SUBDIVISION �
PHASES 2, 3 &4 PB 73 PG 059
BLOCK 4 Taxable Value $26,950
LOT 4
7urisdiction '
City of Zephyrhills
i
Land Detail (Card: 001 of 001) '
Line _ Use DescriptionZoning Units Type Price Condition Value �
2 0100 SFR MPUD , 1,668.00 SF $0.33 �1.00 , �$550 0
Additional Land Information
���� � FEMA `�
Acres � 0.18 I�Tax Area�30SI � Code E -- � Residential Code � SLVRCPI
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
_ Extra Features (Card: 001 of 001) �
Line Dei scriptio Year Units Value
No Extra Features i
Sales History - See All 6 sales i
Previous Owner: DUNE FL LAND I SUB LLC �
Month/Year ���� �'-'
^ Book/Page Type �DOR Code Condition Amount �
_ 08/2017 9590 / 2919 Warranty Deed �__ 05 Vacant Multi-Parcel Sale j
_ 09/2011 8606 / 3376 Warranty Deed 05 Vacant , Multi-Parcel Sale .
05/2010 8373 / 1912�� Certificate of Title 12 � Vacant � , $0
;
�
I
�
http://search.pascopa.com/parcel.aspx?sec=05&twn=26&rng=21&sbb=0070&b1k=00400... 8/21/2017
12= � - - � ir _io� � . � -• - �l, 11 �, �1 ' ' ' '�'� � � ' -
4' r+ � �1�v ' 1 1 � �
� � '
� r ,�=. - � ' - �O �� _5 �_,os.90 �=,,os.7o p � �_ �
t a•r �F=1 Q4.60 : +
�� �`� � � �- LOT 12 - ' � _ ��� `'o-`� LOT 2 LOZ 1 �'� '• �"
� ' t t � Fj ,.,p�p 1 � PAD=109.0 ' � ��'.
� i PAB=108_9 � .
f � _ �� � ��� �� � .05 _ °J. `� O� U�-��� �c��.;1�� `fi 7YPE A ��� -
� i ,� T� '
r ,r 1 . `� � � FF=14,�T�0 - - a{�' ,0 � � ' •
� i • ;�' ' � 6. �ie- !` y\ '7' � � �� LaT 9 a�$� � 5 � .
I m � s- � `� � �s- � �,�� � PAD=109.6 ' �
�\ u- �� o � n- r � ` � I . .� O�' � � TYPE A . �� �� �
. � ,.• .ir o- � ;1 � �
5• �\ . Tr m �,, ', �� � 11D. �
�-`\,re' ♦ r' � � FF=1�9.50 ;,1 )� , � �� ,� � ; �� 1 ti,�
� ` ,��
\. o a' �\ ." 7D• c �28' p L��1 OSB.g�1z• �17� J � �'r T 0\ g. �� C - v � 0 �
6 � �q � F 1' 6• 6� .� PE l�J r i •'� 1 ��. �1 l� �'` r� , � �'�`� .�� '
, •.\.�,6� � � �� _� e � 01 t�� ' � LOT_�� 9• -�• �� O�` ��0� ��` '� `p��k° E
- �Ta-� O C��" Br s-e '• � � S • �` ^ PAD=110.0 i-��� =� 'o^ �_ FF=110_30 �-� _ o'F •
� � f ` -
� �6 Q _ 6' •, I � � � TYPE A PAQT109."0 �� ��`ti
�Q � FF=110.80 FF=110_60 �E A
�,
E� �'`�` s� U �`\ _20 ''� '"�Q- FF=108e.�i� � - O � �. LOT 11 LaT 12 � O
� �Q PAD=110.1 PA�109.9 � �`D �
_�• .
�\ ' b�; y ' � L O ja:l. �'e- � p1 1 �. • T Y P E A T`!PE A ,� �
� �� ' s�,�, PAD�-� T i 0'1 p��`J-. � ` , '1 '` � ^
• � . �� - � c \o�=� � �,a 6 ,,� o � 2 .,� ��
.
�^'e-Pi' �\ o • � ,�.�� - 6 _'��b _����. ��� �� � �JJ �� �� �'V �a� r1 -'r� . f� � n
.n 4 (oQ r . 1 C�� � �1 _\ 1 � ,�r1Q'� 1'�" TT� Y. ,.�f6�.'J3 �� ';-�V� �a
+.-� �� �1 �^ 1 ---I � I.LbTI . . , __ ',' �O 1�
' '�i�`���n , 20' DRAINAGE EASEMEN7 � �e � �, pp s1 `70' U77 '
` ` 1
� , =�;----�,----- }8 �� � ,�. � -Fas�n,FUT
. ������ �
h' �
� 6''' \\ � �'-Y` �6� .,i� `Cl'ry � ^ � ^ =�\��.� Q'`
�_�9• __ 9.��� '� �1�H.80 � '�� -�u .L _� ,'' r .\ � , •.�",,Oa� � ��y �.
� (�T 9 �; � . � �, ,�a,�`� ��1
,. 9'� OB" a�l'D 108.1 $ � �.. � .` ``�v sc "' _ ,�r� ��r0�'a`�;.,0 •' � ,
� �eT- �� s �PE B 1� ' -_ •.r;----�� `"` , ` , 'r� 7.`� , � . - -" �`� ; __-' -�`� �
�, `' ,S �I�GCl2<'1 PI - -_,___', _ . � `_� _ -__'' � ' � 1
' (pJ ` , � -'' � l
' T . � ., P - � -- ��� UTiuiY _ ' _� _ _ �
�1 . p �, , - - ��r-�
7�(88.8 . FF=109.90
. �� ��,r • e Ff'=1�9_00 _. . LOT 1 ,\
r1 ,a- ' ___ `�
iz• , �- LQT,,��' PAD=109.2 _ �
a�," r� „C� - �• �--FF=110.7D
PAQ,�'08.3 FF=7�9_20 _ ��T Z 'tYPE 8 � �
,<- .. FF=1t0.2 � � FF=11�_50 FF=110_3Q.� � �.� --�-' .
' , ;.°� � ,�• � TYPE�� . LC�T 7 �� LOT �' FF=110_50
50 . ,<- ' �5- LOT 5 - PAD=1o9.d �
, � (A�, PA�-1o8.5 LOT 4 LOT_•3" (�• " g�
��} g � �"�`� ' �STYPE B �PATD�-��8.5 PAI2=ffg3�8 PAD=t 09.8 PAD=109.6 7YPE B �� _,�0 . O �
� � � .g_;�„- , � ': �.. ��'� 1YPE BJ�I TYPE B �C� . �� �+ c
�- "�� � �.`7 1 1 107_ d-
•�ro �@, r� r � �\v•, i • __ - � �
�tr � -- 9
.� r� � y19. `. O •. , - ------ -- ��~' _ e �
.� B.� - � .�'T� �-� �� - �0 G 4 � '
� �o�y • ..``, - - ni' � Dc '� 1 " `1
o. r �t.-.
�� �� '�, c.,, s• , �O r` _r1� _'� - qv• �� C� 18'(87. ` .
�°'S ��,��\-,y�`Z� �a� . . " ��'- ,�c �� _ ��,-' s� '`
�4 �-S'. ���\` `��d` _ ' ' ' _ _ ' ' ' ' ' ' T • fa'_ __- �• J-• .��� � l.
WETLAND ��� � �. . _ . _ ,
� � � � _
� CONSERVATION ���� �����. r�� -� � - ���
4. �ia• � � ` ` .s• �1r' - � � �'Q'C -�'�.g6 F1.
AREA P �� ' �"- �� ���� _�-R r i,�,-�,,g� °-���� . �},�
'�e- g� �\ a- �'; i ,i• � ��• . P1'Or �"'Y r, _"�°�5---�'� ,'•
.,� ��19 - . , � ^
- �i6'���t✓ V��� T, �- y,.' i�.JT� PiS e�� �a�- SY ' T��_'�-�+��
� . (1 .22) AC. __ _ . . -- ._\ o � ,` � ,. _ - �� _ �'�� P� � � o�-•-��-J
`'�� -� � �. , �� .� ��-����
` . l OOIRDHW=104.0 -- __ --- . CONTROL SFRUC7UR�C �e�s- � . ��Q ' '` '• • .� _ '�. v-a- �l�r r o.��% �
.�
, '--- _ •.4;•^ � � �`�a`� � � s- ,-j'�e
- - - _ --- . -- ••-__�-- _--- -- - � �s�' - ,�� - -� --�� --- ---- - -
.. . C �� T \ __ �c-- f��
'o"� - ,r �O �,.
' r
_ •
.. � .. - .. _____ '-_ ' ' " _"' __
- S ' 8r ' ' _ - __ '_'_-_- _
' � ' � '--- Ar] SF Rf 1RAI� � 6�� �� - �__�� .a
PLOT PLAN S+�ETCH oN�Y SEC. 05 , TWP. 26 S, RNG. 21 E. I
NOT A B�JUNDARY SURVEY
LOT 4, BLOCK' 4 , BEARING BASIS: ,
SILVERADO RANCH SUBDIVISION NORTH BOUNDARY OF SE% OF OS-26-21 BEING N 89'25'Ot" E
PHASES 2, 3 & 4 ` � "'
PASCO COUNTY, FLORIDA. '�T THIS SURVEY IS SUBJECT TO ANY FACTS THAT
j� MAY BE DISCLOSED BY A FULL AND ACCURATE�
. TITLE SEARCH. ALSO SUBJECT TO SETBACKS,
PRELIMINARY DRAWING: _ EASEMENTS AND RESTRICTIONS OF RECORD. ,
THIS PLAN IS FOR PERMITTING PURPOSES
ONLY, NOT FOR CONSTRUCTION. VERIFY M UNDERGROUND FOOTER, STEM WALL, AND
ALL DIMENSIONS BEFORE ANY CONSTRUCTION. p UNDERGROUND UTILITIES ARE NOT LOCATED OR
SHOWN.
LEGEND: ^ DO NOT SCALE THIS PRINT. DIMENSIONS AND '
.�—►= PROPOSED DRAINAGE FLOW w
Q NOTES TAKE PREFERENCE. j
(00.00) = PROPOSED GRADE �
E-00.00 = EXISTING GRADE � DESCRIPTION NOT CONTAINING PLAT BOOK AND ,
PAGE INDICATES THAT PLAT IS IN
NOTES: PRELIMINARY STAGE AND IS SUBJECT TO I
LOT GRADING TYPE = B CHANGE AND/OR REVISION. i
PROPOSED PAD ELEVATION = 109.8' CERTAIN DATA SH04VN HEREON BASED ON
FRONT SETBACK = 20' or 22' ENGINEERING PLANS PROVIDED BY CLIENT. �
SIDE SETBACK = 7.5'
REAR SETBACK = 15' STRUCTURE TIES SHOWN HEREON DENOTES '
MEASUREMENT FROM FORM BOARDS/FOUNDATION
TO PROPERTY LINE.
�EN�6 wHEEL SrREET * - 10' UTILITY EASEMENTI
� �(T���—
��pC�p '�` o . ON LOT AREA CALCULATIONS
� � o LOT = 7668.91_SQ. FT.
� � ' —
'•" :.. . ' _ o REA _ —
,.
:.�..., ' ._. . -------
''•,:.:• Q. FT
. .••..t. ', • _
,..
�.p�:a-�.:.,;',.'.�. �. ': :*�, .� D NAI -- —SQ FT
S
ENTRY 38 g , _
GARAGE 611 SQ. FT.
, - . , , COVERE LA = 181
� : •• .� ����: PA110 =—NJA--SQ. FT.
,o$$e� �y •.C177,":K'`,-'. ' ' .• . ;4: CONC. DRIVE = 593 �_SQ. FT.
L �. :•..:24.00'�.�•::. �'�' .: . . A/C & CONC PAD = 13 _SQ. FT.
� • • ... , ' rio PRIVATE SIDEWALK = 51---�SQ. �.
� �- .:`. ��. 8s IMPERVIOUS =_39 �%
� �; � ���""-_� o `�J = 2999 _SQ. FT.
� �;� M; N N. � SOD =_ 4670�SQ. FT.
� � • .'zs.00' . � OFF LOT AREA CALCULATIONS
, ��ry RIGHT OF WAY = 1145.00 gp, �,
8'1e N DRIVE APRON = 3_50 _SQ. FT.
�
2 PUBLIC SIDEWALK = 324 _SQ. FT.
- v SOD = 471_�_SQ. FT.
8.18' �
z TOTALS
� 48�-8" �
� N 88•38'ia.w 8.20' AREA = 8813.91 SQ. FT. ,
N . 3 � 0 � _ DRIVEWAY =_ 943 __SQ. FT.
LOT 5 . � PROPOSED PLAN: �a A�C � LOT 3 SIDEWALK = 375 �_SQ. FT.
BLOCK 4 3127 �� BLOCK 4 SOD = 5141 SQ. FT.
o� ELEV B �a � �
`,09`' GARAGE LEFT " �� �
w LOT 4 °s '
� BLOCK 4 �`�oJ
�
�1- �
N �
8.27' 16.90' �
O .
Z �
. �
� .n �. I
•M M �
� M.
n
�
" 5°� N 88°35'27" W 65.16' �'o
� ��o�' �
� TRACT J SO3
� DRAINAGE AREA
� '
�
�
a CURVE RADIUS ARC LENGTH DELTA ANGLE CHORD LENGTH CHORD BEARING PROPOSED.
CO 337.00' 96.01' 16'19'29" 95.69' S 69'34'18" E
' c,�� 337.00' 65.35� i,•oe�38" 65.25' S 83'17�za•� E LOWEST FLOOR ELEVATIONS:
LIVING AREA: 110.50'
' DESCRIPTION: GARAGE AREA:
i LOT 4, BLOCK 4, MAP OR PLAT ENTITLED "SILVERADO RANCH SUBDIVISION ELEVATIONS REFERENCED TO
NORTH AMERICAN VERTICAL�
PHASES 2, 3 & 4", AS RECORDED IN PLAT BOOK 73, PAGES 59 DATUM OF 1988. MEAN SEA
� THROUGH 65, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT.
�
�
APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL N0. 12101C 0288 F EFFECTIVE DATE: 9/26/14
�Project: SILVERADO RANCH Square Feet: 7668.91 t LENNAR HOMES
LEGEND:
(C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, r�= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
� CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
�PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOIC, P6= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
a REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK,
� U P= UTILITY POLE, W F= WOOD FENCE, R = RADIAL
JOHN R.BEACH&ASSOCIATES�INC. Drawn By:
� SURVEYORS AND MAPPERS JBS
971 WEST ST. PETERSBURG DRIVE Checked By.
� WAY OLDSMAR, FLORIDA 34677 JRB i
(813) 854-1276 FAX (813) 855-8370 Scale:
� �,�_30' I
: NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 6 27 17 ACS A� ��j,dj
`THE ORIGINAL RAISED SEAL OF A FLORIDA N . EACH ATE
v LICENSED SURVEYOR AND MAPPER FLORIDA LAND SURVEYOR No. 2984 LB//4493
Revisians:
.,� i
�_ _ � _ _ _
FORM R405-2014 �
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION �
�
Florida Department of Business and Professional Regulation - Residential Performance Method �
i
Project Name: 3127B sfADS BuilderName: CENNAR HOMES �
str�et: 6503 Paden Wheel Street Pertnit Office: Clty„gf��e�hyrhills ;
City,State,Zip: ,FL, Permit Number ��3
Owner LENNAR HOMES Jurisdiction: 611600
Design Location: FL,Tampa County Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. WaII Types(2907 1 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ftZ
b.Concrete Block-Int Insul,Exterior R=4.1 13�9.80 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ft2
4 Number of Bedrooms 5 d.N/A R= ftZ
5. Is this a worst case? Yes 10.Ceiling Types (1946.0 sqft.) Insulation Area Z
a.Under Attic(Vented) R=30.0 1772.00 ft
6. Conditioned floor area above grade(ft2) 3127 b.Knee Wall(Vented) R=30.0 174.00 ftZ
Conditioned floor area below grade(ftz) 0 c.N/A R= ft'
11.Ducts R ftZ
7. Windows(366.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 302.4
a. U-Factor� Dbl,U=0.54 162.68 ft2 b.Sup. Attic, Ret:2nd Floor,AH:2nd Floor 6 323
SHGC: SHGC=0.31
b. U-Factor Dbl,U=0.56 117.00 ft' 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00
b.Central Unit 25.2 SEER:16.00
c. U-Factor: Dbl,U=0.56 86.67 ft' _
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency �
d. U-Factor� N/A ft2 a.Electric Heat Pump 21.8 HSPF:8.50
SHGC: b.Electric Heat Pump 21.8 HSPF:8.50
Area Weighted Average Overhang Depth: 4.220 ft. �
Area Weighted Average SHGC: 0.303 14 Hot water systems
a.Electric Cap:40 gallons
8. FloorTypes (3181.0 sqft.) Insulation Area EF•0.950
a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ft� b. Conservation features
b.Floor Over Other Space R=0.0 1409.00 ft' None
c.other(see details) R= 260.00 ft2 15.Credits Pstat
Total Proposed Modified Loads: 90 98
Glass/Floor Area: 0.117 - PASS
Total Baseline Loads. 92.81
� I hereby certify that the plans and specifications covered by Review of the plans and ��''C���7'��.� .
this calculation are in compliance with the Florida Energy specifications covered by this �v d���O�,. .
Code. calculation indicates compliance ���i,r��;`,, Y:;A�,.,`„o�,`t�.
�a�e �G�l�rc% with the Florida Energy Code. � -1rr��,�'.��%�:::.a'.,•'.,��;t O
< �"::s" >::,�t+�., .�
PREPARED BY: Before construction is completed w. �-• �
DATE. this buildin will be ins ected for �" `�"'"�" -- � � '
9 P t7 �.�,,� �+,
compliance with Section 553.908 �� � a
I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. , � � ;
Y � 9, 9 P ��' �°s. i
with the Florida Energy Code. _ �'42>yy�;� ,
� OWNER/AGENT. BUILDIN OFFICIAL.
DATE: DATE: �`
I
- Compliance requires certification by e air handler unit manufacturer that the air handler enclosure qualifies as 1
certified factory-sealed in accordance with R403.2.2.1. �. I
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2. �
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, �
tested in accordance with Section 803 of RESNET Standards,is not greater than 0.050 Qn for whole house.
7/10/2017 12:03 PM EnergyGaugeOO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 '
\
� , � �
� - I
FORM R405-2014 , I
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION �
Florida Department of Business and Professional Regulation - Residential Performance Method I
Project Name: 3127B sf ADS Builder Name: LENNAR HOMES �
street: 6503 Paden Wheel Street Permit office. City of Zephyrhills a
City,State,Zip: ,FL, Permit Number:
Owner• LENNAR HOMES Jurisdiction: 611600
Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) �
1 New construction or existing New(From Plans) 9. Wall Types(2907.1 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ft'
b.Concrete Block-Int Insul,Exterior R=4 1 1309.80 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ftZ
4 Number of Bedrooms 5 d.N/A R= ftZ
5. Is this a worst case? Yes 10.Ceiling Types (1946.0 sqft.) Insulation Area Z �
a.Under Attic(Vented) R=30.0 1772.00 ft
6. Conditioned floor area above grade(ft2) 3127 b.Knee Wall(Vented) R=30.0 174.00 ftZ
Conditioned floor area below grade(ftz) 0 c.N/A R= ftz
11 Ducts R ftZ
7. Windows(366.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH: 1st Floor 6 302.4 �
a. U-Factor Dbl,U=0.54 162.68 ftz b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 323
SHGC: SHGC=0.31 �
b. U-Factor Dbl,U=0.56 117.00 ftz 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00
b.Central Unit 25.2 SEER:16.00
c. U-Factor• Dbl,U=0.56 86.67 ftZ
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor• N/A ft= a.Electric Heat Pump 21.8 HSPF:8.50
SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 ,
Area Weighted Average Overhang Depth. 4.220 ft.
Area Weighted Average SHGC: 0.303 14 Hot water systems
8. Floor Types (3181.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF 0.850
a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ftZ b. Conservation features
b.Floor Over Other Space R=0.0 1409.00 ft2 None
c.other(see details) R= 260.00 ftz 15.Credits Pstat
Glass/Floor Area: 0.117 Total Proposed Modified Loads: 90.98 PASS
Total Baseline Loads. 92.81
- . �
I hereb certi that the lans and s ecifications covered b Review of the lans and 'Y���"` '
Y fY P P Y P ��:. ,4��,.
this calculation are in compliance with the Florida Energy specifications covered by this �. , , �= p�,,,
. r
Code. calculation indicates compliance ���i,,;'' '�:=,�``�.�. �
with the Florida Energy Code. C.��rrru�:`°%;:���.�•` "��a f0.
+`�a
/,,� /. �"�r?o�i:fiu.,
PREPARED BY: �aV� �Wl{�l�Vl Befare construction is completed � � " ''�'`-*
��� C7
DATE: this building will be inspected for �ry�,;��; . •:�. I
compliance with Section 553.908 *
�� �•.
Florida Statutes. :r� �� �
I hereby certify that this building,as designed, is in compliance �.� - .. ,��.- i
with the Florida Energy Code. �D yyfi'�'
' �
OWNER/AGENT. BUILDING OFFICIAL.
DATE. DATE: �
- Compliance requires certification.by the air handler unit manufacturer that the air handler enclosure qualifies as_
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2. � �
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, ,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.050 Qn for whole house.
7/10/2017 12:03 PM EnergyGauge�USA-FlaRes2014 Section R4�5.4.1 Compliant Software Page 1 of 5 �
.. s II
FORM R405-2014
• � , I
i
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION �
Florida De artment of Business and Professional Re ulation - Residential Performance Method
p 9. I
�
I
Project Name: 3127B sf ADS Builder Name: LENNAR HOMES �
screet: 6503 Paden Wheel Street Permit otfce: City of Zephyrhills ;
City,State,Zip: ,FL, Pertnit Number:
i
Owner• LENNAR HOMES Jurisdiction: 611000
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) ,
1. New construction or existing New(From Plans) 9. Wall Types(2907.1 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ftZ
b.Concrete Block-Int Insul,Exterior R=4.1 1309.80 ftz
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ftZ �
4. Number of Bedrooms 5 d.N/A R= ft'
5, is this a worst case? Yes 10.Ceiling Types (1946.0 sqft.) insulation Area 2
a.Under Attic(Vented) R=30.0 1772.00 ft �
6. Conditioned floor area above grade(ft2) 3127 b.Knee Wall(Vented) R=30.0 174 00 ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft'
11 Ducts R ft2
7. Windows(366.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 302.4
a. U-Factor• Dbl,U=0.54 162.68 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 323
SHGC: SHGC=0.31 '
b. U-Factor Dbl,U=0.56 117.00 ft' 12.Cooling systems kBtu/hr Efficiency ;
SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00
b.Central Unit 25.2 SEER:16.00 �
c. U-Factor Dbl,U=0.56 86.67 ft'
SHGC: SHGC=0.32 13.Heating systems � kBtu/hr Efficiency
d. U-Factor N/A ftz a.Electric Heat Pump 21.8 HSPF:8.50 i
SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 ,
Area Weighted Average Overhang Depth. 4.220 ft.
Area Weighted Average SHGC: 0.303 14 Hot water systems !
a. Electric Cap:40 gallons
8. Floor Types (3181.0 sqft.) Insulation Area EF 0.950
a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ftz b. Conservation features
b.Floor Over Other Space R=0.0 1409.00 ft' None
c.other(see details) R= 260.00 ft= 15.Credits Pstat
Totai Proposed Modified Loads: 90.98
Glass/Floor Area: 0.117 PASS
Total Baseline Loads: 92.81
� .
I hereb certi that the lans and s ecifications covered b Review of the lans and 'C�:�T � �
Y fY P P Y P p4: _ �?,�.,
this calculation are in compliance with the Florida Energy specifications covered by this °�,. ,� � _ � p�,
Code. calculation indicates compliance �,j'�v, � ��;,��•` +� ,
,{/,,� /. with the Florida Ener Code. �' jrrrr,�:'���..;:_��'•'''��`;�{O .
���Qi Wl 9Y �' .: ' :�`'�::+�. .'�
PREPARED BY. r[ ���'c Before construction is completed w &-- ", , " .-
DATE: this building will be inspected for s�,ry '"��`'" � .
�N��i '
compliance with Section 553.908 * .�'-�'- '� ;, �
I hereby certify that this building, as designed, is in compliance Florida Statutes. �,i,�- . � ��•q. :
with the Florida Energy Code. �D H*E.'T� �
�� I
OWNER/AGENT. BUILDING OFFICIAL., `-Z���"` �
DATE: - DATE. '%'_�r �'1 I ,
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certifed factory-sealed in accordance with R403.2.2.1. I
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, �
tested in accordance with Section 803 of RESNET Standards,is not greater than 0.050 Qn for whole house. �
7/10/2017 12:03 PM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 '
FORM R405-201� � • '
PROJECT
Title: 31278 sf ADS Bedrooms: 5 � • Address Type. Street Address I
Building Type: User Conditioned Area: 3127 Lot#
Owner: LENNAR HOMES Total Stories: 2 Block/SubDivision. I
#of Units: 1 Worst Case: Yes .. PlatBook:
Builder Name: LENNAR HOMES Rotate Angle: 45 Street: �
Permit Office: Cross Ventilation. No _ County� Pasco I
Jur�sdiction: Whole House Fan: No City,State,Zip: ,
Family Type: Single-family FL, i
New/Existing: New(From Plans)
Comment: legacy ;
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
\� Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium '
BLOCKS
Number Name Area Volume I
1 Blockl 1512 14061.6
2 Block2 1615 12920 I
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated
1 1st Floor 1512 14061.6 Yes 1 1 1 Yes Yes Yes ;
2 2nd Floor 1615 12920 No 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio 1 st Floor 173 ft 0 1512 ftz ___ 0.3 0 0.7
2 Floor over Garage 2nd Floor ___ ___ 260 ftz 11 0 0 1 i
3 Floor Over Other Space 2nd Floor _�_ __, 1409 ftz 0 0.2 0 0.8 �
I
ROOF
I
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
\� # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) I
�
1 Hip Composition shingles 1982 ftz 0 ft2 Medium 0.85 No 0.9 No 0 26.6 �
ATTIC I
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1772 ft2 N N
I
7/10/2017 12:03 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 2 of 5
� ' �
FOFtM R405-201� � • ' I
_ CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) 2nd Floor 30 Blown 1772 ftZ 0.1 Wood
2 Knee Wall(Vented) 2nd Floor 30 Batt 174 ft' 0.11 Wood I
WALLS i
Adjacent SPa� Cavity Width Height Sheathing Framing Solar Belo w I
_ 1 N=>NE Exterior Concrete Block-Int Insul 1 st Floor 4.1 7 6 9 4 70.0 ftZ 0 0 0.6 0 '
_2 N=>NE Exterior Concrete Block-Int Insul 1 st Floor 4 1 12 6 9 4 116.7 ft� 0 0 0.6 0 �
_ 3 E=>SE Exteriar Concrete Block-Int Insul 1 st Floor 4 1 45 4 9 4 423.1 ftZ 0 0 0.6 0
_4 S=>SW Exterior Concrete Black-Int Insul 1 st Floor 4.1 14 4 9 4 133.8 ft2 0 0 0.6 0
_ 5 W=>NW Exterior Concrete Block-Int Insul 1 st Floor 4.1 4 0 9 4 37.3 ft2 0 0.6 0
_6 S=>SW Exterior Concrete Block-Int Insul 1 st Floor 4 1 25 8 9 4 239.6 ftZ 0 0.6 0
_7 W=>NW Exterior Concrete Block-Int Insul 1st Floor 4.1 31 0 9 4 289.3 ftz 0 0.6 0 �
_ 8 N=>NE Garage Frame-Wood 1 st Floor 11 19 4 8 0 154 7 ftz 0.23 0.01 0 '
_ 9 W=>NW Garage Frame-Wood 1 st Floor 11 6 8 8 0 53.3 ftZ 0.23 0.01 0
_10 NW=>N Exterior Frame-Wood 2nd Floor 11 7 6 8 0 60.0 ftz 0.23 0.6 0
_11 N=>NE Exterior Frame-Wood 2nd Floor 11 29 4 8 0 234.7 ft� 0.23 0.6 0 �
_12 NE=>E Exterior Frame-Wood 2nd Floor 11 7 6 8 60.0 ft' 0.23 0.6 0 '
_13 E=>SE Exterior Frame-Wood 2nd Floor 11 44 8 8 357.3 ft2 0.23 0.6 0 �
_14 S=>SW Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft= 0.23 0.6 0
_15 W=>NW Exterior Frame-Wood 2nd Floor 11 44 8 S 0 357.3 ft2 0.23 0.6 0 "
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>NE Insulated ist Floor None .2 3 6 8 20 ft2
2 N=>NE Wood 1st Floor None .4 2 8 6 8 17.8 ft'
WINDOWS
Orientation shown is the entered orientation(_>)changed to Worst Case. �
/ Wall Overhang
\/ # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 7.0 ft' 6 ft 4 in 0 ft 6 in None Exterior 5
i
2 N=>NE 2 Metal Low-E Double Yes 0.56 0.28 32.0 ftZ 1 ft 0 in 13 ft 8 in None Exterior 5
3 E=>SE 3 Metal Low-E Double Yes 0.54 0.31 23.0 ftZ 1 ft 0 in 10 ft 8 in Drapes/blinds Exterior 5 i
4 S=>SW 4 Metal Low-E Double Yes 0.54 0.31 23.0 ftZ 1 ft 0 in 1 ft 6 in None Exterior 5 i
5 W=>NW 5 Metal Low-E Double Yes 0.56 0.32 33.3 ft' 25 ft 8 in 1 ft 3 in None None
6 S=>SW 6 Metal Low-E Double Yes 0.56 0.32 53.3 ftz 7 ft 0 in 1 ft 3 in None Exterior 5 I
I
7 W=>NW 7 Metal Low-E Double Yes 0.54 0.31 32.0 ft2 1 ft 0 in 10 ft 8 in None None i
8 NW=>N 10 Metal Low-E Double Yes 0.56 0.28 16.0 ft� 1 ft 0 in 0 ft 8 in None Exterior 5
9 N=>NE 11 Metal Low-E Double Yes 0.56 0.28 23.0 ftz 1 ft 0 in 0 ft 8 in Drapes/blinds None
10 NE=>E 12 Metal Low-E Dou61e Yes 0.56 0.28 16.0 ftz 1 ft 0 in 0 ft 8 in Drapes/blinds None
11 E=>SE 13 Metal Low-E Double Yes 0.54 0.31 6.7 ft' 1 ft 0 in 0 ft 8 in Drapes/blinds None +
12 S=>SW 14 Metal Low-E Double Yes 0.54 0.31 69.0 ftZ 1 ft 0 in 0 ft 8 in Drapes/blinds None �
13 W=>NW 15 Metal Low-E Double Yes 0.54 0.31 9.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None
7/10/2017 12:03 PM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Soflware Page 3 of 5
�
FORM R405-2014 � • �
WINDOWS
Orientation shown is the entered orientation =>)chan ed to Worst Case.
/ Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
14 N=>NE 11 Metal Low-E Double Yes 0.56 0.28 23.0 ftZ 1 ft 0 in 0 ft 8 in Drapes/blinds None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter� Avg.Wall Height Exposed Wall Insulation I
1 611 ftZ 611 ftZ 72 ft 9.3 ft 1 I
INFILTRATION ,
# Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 ,
1 Wholehouse Proposed ACH(50) .000384 3147.9 172.81 325 .3544 7
HEATING SYSTEM �
# System Type Subtype Efficiency Capacity Block Ducts �
1 Electric Heat Pump None HSPF:8.5 21.8 kBtu/hr 1 sys#1 !
2 Electric Heat Pump None HSPF:8.5 21.8 kBtu/hr 2 sys#2 �
COOLING SYSTEM
�
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts i
1 Central Unit Split SEER: 16 25.2 kBtu/hr 756 cfm 0.85 1 sys#1 ;
2 Central Unit Split SEER:16 25.2 kBtu/hr 756 cfm 0.85 2 sys#2
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None g= i
DUCTS I
, i
�
/ —Supply— —Retum— Air CFM 25 CFM25 HVAC# �
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool �
1 Attic 6 302.4 ft 1st Floor 75.8 ftz Proposed Qn 1st Floor —cfm 75.6 cfm 0.05 0.60 1 1
2 Attic 6 323 ft2 2nd Floor 80.75 ft Proposed Qn 2nd Floor —cfm 80.8 cfm 0.05 0.60 2 2 I
. I
�
_ �
I
I
I
7/10/2017 12:03 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
� � �
FORM R405-2014 � • ' I
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Coolin Jan Feb [ ]Mar A r Ma [X]Jun Jul [X]Au X Se Oct [ ]Nov Dec I
Heatin9 �Jan �Feb [X]Mar E�APr f �May [ ]Jun ��Jul [ ]Aug 4 �SeP E �Oct [X]Nov f X�Dec I
Ventin Jan Feb [X]Mar [X]A r [ Ma [ ]Jun Jul [ ]Au [ Se [X Oct [X]Nov [ ]Dec
I
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 _ 3 4 5 6 7 8 9 10 11 12 ,
I
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 �
PM 80 80 78 78 78 78 78 78 78 78 78 78 �
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 7S 78 78 78 78 78
Heating(VVD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66 �
MECHANICAL VENTILATION
Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System
None 0 0 0 1 -Electric Heat Pump 0% 1 -Central Unit
None 0 0 0 . 2-Electric Heat Pum 0% 2-Central Unit
I
I
I
I
i
�
I
I
�
�
1
I
_ �
I
j
7/10/2017 12:03 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
I
'i
FORM R405-2014 ' • 'I
ENERGY PERFORIIIIANCE LEVEL (EPL)
D�ISPLAY CARD �
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index,the more e�cient the home. i
„ F�, � 'i
1 New construction or existing New(From Plans) 9. Wall Types Insulation Area
' 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ft2
b.Concrete Block-Int Insul,E�erior R=4 1 1309.80 ft
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ftz ,
4 Number of Bedrooms 5 d.N/A R= ft'
5. Is this a worst case? Yes 10.Ceiling Types Insulation Area 2 �
a.Under Attic(Vented) R=30.0 1772.00 ft
6. Conditioned floor area(ft� 3127 b.Knee Wall(Vented) R=30.0 174.00 ft'
7. Windows" Description Area c.N/A R= ftz
a. U-Factor• Dbl,U=0.54 162.68 ft2 �1 Ducts R ft�
a.Sup:Attic,Ret:1st Floor,AH: 1st Floor 6 302.4
SHGC: SHGC=0.31 b.Sup: Attic, Ret:2nd Floor,AH:2nd Floor 6 323 �
b. U-Factor Dbl,U=0.56 117.00 ft�
SHGC: SHGC=0.28 12.Cooling systems kBtulhr Efficiency
c. U-Factor Dbl,U=0.56 86.67 ftZ a.Central Unit 25.2 SEER:16.00 ,
SHGC: SHGC=0.32 b.Central Unit 25.2 SEER:16.00 ,
d. U-Factor N/A ft' 13.Heating systems kBtu/hr Efficiency
SHGC• a.Electric Heat Pump 21.8 HSPF:8.50
Area Weighted Average Overhang Depth: 4.220 ft. b.Electric Heat Pump 21.8 HSPF:8.50
Area Weighted Average SHGC: 0.303
', 8. Floor Types Insulation Area 14 Hot water systems
Z a.Electric Cap:40 gallons
� a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ft EF.0.95
b.Floor Over Other Space R=�.O 1409.00 ft2
c.other(see details) R= 260.00 ft' b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building :,��E��
Construction through the above energy saving features which will be installed (or exceeded) o� - "��'r � ;
in this home before final inspection. Otherwise, a new EPL Display Card will be completed �k��"�s�`� _ � ..��',%
based on installed Code compliant features. h +e,F:�"k-==;�;;���,;�o. ,
�` ,�
Builder Signature: Date. 07/10/17 ��-- . . � f
I
,' #. .�� . ' .'. ,� �
Address of New Home. 6503 Paden Wh el Street City/FL Zip�Zephyrhills, - `� �
FL 33541 �c �y� .
a�'WE"�` i
�
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For I
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
*'`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
�
7/10/2017 12:07 PM EnergyGauge�USA-FlaRes2014 -Section R405.4 1 Compliant Software Page 1 of 1
� . ►
� Jo6: 3127B sf ADS I
Building Analysis Date: 7110/17 I
lower floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
o • ' ! 6 �
For: Lennar Homes -
�
� I
■ - • • e e
i
Location: Indoor: Heating Cooling '
Tampa InternationalAP, FL, US Indoor temperature(°F) 70 75 �
Elevation: 10 ft Design TD (�F) 39 16
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7 �
Dry bulb(°F) 31 91 Infiltration: ,
Daily range(°F) - 14 ( L ) Method Simplified
Wet bulb(°F) - 77 Construction quality Semi-tight �
Wind speed (mph) 15.0 7.5 Fireplaces 0 ;
• '
Component Btuh/ft2 Btuh % of load
Walls 5.5 6921 28.5 ��ts �
Glazing 29.9 6331 26.1 Wap nfiltration
Doors 23.5 466 1.9 '
Ceilings 1.3 281 1.2 i
Floors 3.8 5699 23.5 i
Infiltration 1.9 2752 11.3
DUCts 1852 7.6 F�oors
Piping 0 0
Humidification 0 0 °`�' '
Ventilation Q Q Glazing Other
Adjustments 0
Total 24301 100.0
' s • e ,
Component Btuh/ftZ Btuh % of load ;
Walls 2.8 3491 17.7 '
Glazing 46.5 9834 4g.g waus Intemal Gains j
Doors 18.4 365 1.8 j
Ceilings 1.5 317 1.6 �ucts I
Floors 0 0 0
Infiltration 0.4 595 3.0 I
Ducts 2136 10.8 Infiltration I
Ventilation 0 0
Internal gains 3020 15.3 otner i
Blower 0 0 �
Adjustments � Glazing
Total 19757 100.0
Latent Cooling Load=2411 Btuh �
Overall U-value= 0.156 Btuh/ft2-°F
Data entries checked. �
I
.� -�1- wrightsoft` 2017-Ju4-10 12:13:06
� Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 �
.S with CBA27UHE AH's\3127C sf drawn 2-2tons.rup Calc=MJ8 Front Door faces: N
BV��d�n Anal $�$ � Job: 31278 sfADS
g y Date: 7110/17
upper floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950.New York ave,Hudson
i
s • ' . � �
For: . Lennar Homes
�
I
i - o • • • I
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD (°F) 39 16
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7 ;
Dry bulb(°F) 31 91 Infiltration:
Daily range(°F) - 14 ( L ) Method Simplified
Wet bulb(°F) - 77 Construction quality Semi-tight �
Wind speed (mph) 15.0 7.5 Fireplaces 0
0
�
Component Btuh/ftz Btuh % of load '
Walls 3.8 4450 28.2 ���
Glazing 30.2 4895 31.1 waii
Doors 0 0 0
Cellings 1.3 2026 12.9 nfiltralion
Floors 0 0 0
Infiltration 19 2471 15.7
Ducts 1914 12.1
Piping � � Ceilings
Humidification 0 0
Ventilation 0 0 Glazing
Adjustments 0
Total 15756 100.0
� a e
Component Btuh/ftZ Btuh % of load �
Walls 2.7 3213 16.9 �,
Walls Intemal Gains
Glazing 46.4 7530 39.6 �
Doors 0 0 0
Ceilings 1.4 2284 12.0 '
Floors 0 0 0 f oucts �
Infiltration 0.4 534 2.8 r
D ucts 2212 11.6 <
Ventilation 0 0 Infiltration
Internal gains 3240 17.0
BloWef 0 0 Glazing Ceilings
Adjustments 0
Total 19013 100.0
Latent Cooling Laad= 3101 Btuh
Overall U-value= 0.098 Btuh/ftZ-�F
, Data entries checked. j
,� -{-}} wri htsaft` 2017-Ju1-1012:13:06
� -1— 9 Right-Suite�Llniversal 2017 17.0.23 RSU05714 Page 2
.S with CBA27UHE AH's\3127C sf drawn 2-2tons.rup Calc=MJS Front Doar faces: N
Pro ect Summ'a � � Job: 3127B sfADS
- � � Date: 7I70/17
�OW@I"f�001� � By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
� i ' i •
For. Lennar Homes I
�
I
Notes ADS specs �
i - e • •
Weather: Tampa International AP, FL, US �
Winter Design Conditions Summer Design Conditions �
Outside db 31 °F Outside db 91 °F
Inside db 70 °F Inside db 75 �F �
Design TD 39 °F Design.TD 16 °F '
Daily range L
Relative humidity 50 % �
Moisture difference 55 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
i
Structure 22450 Btuh Structure 17621" Btuh ,
Ducts 1852 Btuh Ducts 2136 Btuh �
Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh '
none
Humidification 0 Btuh BI wer e� 0 Btuh
Piping 0 Btuh �
Equipment load 24301 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 19757 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 2034 Btuh
Ducts 377 Btuh �
Central vent (0 cfm) 0 Btuh
Heating Cooling (none) ,
Area(ftZ) 1512 1512 Equipment latent load 2411 Btuh
Volume(ft') 16162 16162
Air changes/hour 0.24 0.12 Equipment Total Load (Sen+Lat) 22168 Btuh �
Equiv.AVF (cfm) 64 33 Req. total capacity at 0.85 SHR 1.9 ton �
Heating Equipment Summary Cooling Equipment Summary �
Make Lennox Make Lennox i
Trade 14HPX SERIES Trade 14HPX SERIES
Model 14HPX-024230-21 Cond 14HPX-024-230-21 �
AHRI ref 10258598 Coil CBA27UHE-024230"++TDR
AHRI ref 10258598 �
Efficiency 8.5 HSPF Efficiency 13.5 EER, 16 SEER
Heating input Sensible cooling 21420 Btuh
Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh
Temperature rise 25 °F Total cooling 25200 Btuh I
Actual air flow 800 cfm Actual air flow 800 cfm �
Air flow factor 0.033 cfm/Btuh Air flow factor 0.040 cfm/Btuh �
Static pressure 0 in H20 Static pressure 0 in H20 i
Space thermostat Load sensible heat ratio 0.89
Capacity balance point= 35 °F '
Backup:
. Input=7 kW, Output=24169 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
� wri htsoft" 2017-Ju{-1012:13:07 ,
� g Right-Suite�A Universal 2017 17.0.23 RSU05714 Page 1
.S wRh CBA27UHE AH's\3127C sf drawn 2-2tons.rup Calc=.MJB Front Doorfaces: N
.
Pro ect Summ� � Job: 3127B sf ADS
1 � Date: 7110/17
upper floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
� • ' ! i I
�
For Lennar Homes �
�
Notes ADS specs ;
� - � o s
Weather Tampa International AP, FL, US ;
. Winter Design Conditions Summer Design Conditions �
Outside db 31 °F Outside db 91 °F �
Inside db 70 °F Inside db 75 °F ,
Design TD 39 °F Design TD 16 �F
Daily range L '
Relative humidity 50 %
Moisture difference 55 gr/Ib '
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 13842 Btuh Structure 16801 Btuh
Ducts 1914 Btuh Ducts 2212 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh '
none
(none)
Humidification 0 Btuh Blower 0 Btuh '
Piping 0 Btuh
Equipment load 15756 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00 '
InflltrBtlOn Equipment sensible load 19013 Btuh
Method simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces _ 0 Structure 2708 Btuh
Ducts 392 Btuh ,
Central vent (0 cfm) 0 Btuh
Heating Cooling (none) �
Area (ft2) 1615 161b Equipment latent load 3101 Btuh ,
Volume(ft') 12920 12920
Air changes/hour 0.27 0.14 Equipment Total Load (Sen+Lat) 22114 Btuh
Equiv.AVF(cfm) 57 30 Req. total capacity at 0.85 SHR 1.9 ton �
Heating Equipment Summary Cooling Equipment Summary j
- Make Lennox Make Lennox �
Trade 14HPX SERIES Trade 14HPX SERIES I
Model 14HPX-024230-21 Cond 14HPX-024230-21
AHRI ref 10258598 Coil CBA27UHE-024230*++TDR �
AHRI ref 10258598 i
Efficiency 8.5 HSPF Efficiency 13.5 EER, 16 SEER I
Heating mput Sensible cooling 21420 Btuh j
Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh
Temperature rise 25 °F Total cooling 25200 Btuh I
Actual air flow 800 cfm Actual air flow 800 cfm
Air flow factor 0.051 cfm/Btuh Air flow factor 0.042 cfm/Btuh I
Static pressure 0 in H20 Static pressure 0 in H20 i
Space thermostat Load sensible heat ratio 0.86 '
Capacity balance point=23 °F
Backup:
Input= 5 kW, Output= 16Q62 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �
�-� wrightsoft°° Right-Suile�Universal 2017 17.0.23 RSU05714 2017-Ju1-10 12:13:07
Page 2
...5 with CBA27UHE AH's\3127C sf drawn 2-2tons.rup Calc=MJ8 Front Door faces: N
Manual S Com liarice Re ort Job: 3127B sfADS
P P Date: 7l10/17
lower floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling �
8950 New York ave,Hudson
e � ' � t I
I
For: Lennar Homes
• . • e e
Design Conditions
Outdoor design DB 91.3°F Sensible gain: 19757 Btuh Entering coil DB� 75.6°F
Outdoor design WB: 77 3°F Latent gain: 2411 Btuh Entering coil WB: 62.8°F '
� Indoor design DB. 75.0°F Total gain: 22168 Btuh
Indoor RH� 50% Estimated airflow: 800 cfm �
i
Manufacturer's Performance Data atActual Design Conditions '
I
Equipment type: SpIitASHP ,
Manufacturer: Lennox Model: 14HPX-024230-21+CBA27UHE-024-230*++TDR ,
Actual airflow: 800 cfm �
Sensible capacity� 21420 Btuh 108% of load
Latent capacity: 3780 Btuh 157% of load '
Total capacity� 25200 Btuh -114% of load SHR. 85%
- e . •
Design Conditions
Outdoor design DB 30.8°F Heat loss. 24301 Btuh Entering coil DB. 69.6°F �
Indoor design DB: 70.0°F �
I
Manufacturer's Performance Data at Actual Design Conditions �
Equipment type: SpIitASHP
Manufacturer Lennox Model: 14HPX-024230-21+CBA27UHE-024230*++TDR j
Actual airflow: 800 cfm
Output capacity: 21800 Btuh 90% of load Capacity balance: 35 °F
, Supplemental heat required: 2501 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip i
Manufacturer Model:
Actual airflow: 800 cfm �
Output capacity: 7.1 kW 99% of load Temp. rise: 50 °F �
Meets are all requirements of ACCA Manual S ' I
... wri htsoft4 zo,�-���,0,2:,3:0� �
^� � 9 Right-SuRe�Universal 2017 17.0.23 RSU05714 Page 1
�'� .S with CBA27UHE AH's\3127C sf drdwn 2-2tons.rup Calc=MJ8 Front Door faces: N
. . , �
I
�� � ` Job: 31276 sf ADS I
Manual S Corripliance Report Date: 7/10/17
upperfloor By: DaveAldrich I
Bayonet Plumbing Heating and Cooling �
I
8950 New York ave,Hudson I
- � 0 ' • •
I
For Lennar Homes I
i
• s � . • o j
Design Conditions �
i'
Outdoor design DB 91.3°F Sensible gain: 19013 Btuh Entering coil DB 75.7°F �
� Outdoor design WB. 77.3°F Latent gain: 3101 Btuh Entering coil WB. 62.8°F �
Indoor design DB. 75.0°F Total gain: 22114 Btuh
Indoor RH� 50% Estimated airflow� 800 cfm �
Manufacturer's Performance Data atActual Design Conditions ;
Equipment type: SpIitASHP �
Manufacturer� Lennox Model: 14HPX-024-230-21+CBA27UHE-024230*++TDR
Actual airtlow: 800 cfm '
Sensible,capacity� 21420 Btuh 113% of load
Latent capacity� 3780 Btuh 122% of load ,
Total capacity: 25200 Btuh 114% of load SHR. 85%
e a e '
Design Conditions
Outdoor design DB 30.8°F Heat loss. 15756 Btuh Entering coil DB 69.6°F i
Indoor design DB: 70.0°F i
�
Manufacturer's Performance Data at Actual Design Conditions I
Equipment type: SpIitASHP �
Manufacturer. Lennox Model: 14HPX-024230-21+CBA27UHE-024230*++TDR j
Actual airflow� 800 cfm i
Output capacity: 21800 Btuh 138% of load Capacity balance: 23 °F i
Supplemental heat required: 0 - Btuh Economic balance: -99 °F j
I
Backup equipment type: Elec strip �
Manufacturer Model: i
Actual airflow• 800 cfm j
Output capacity: 4.7 kW 102% of load Temp. rise: 50 °F �
i
Meets are all requirements of ACCA Manual S. '
i
c wri htsoft°� 2017-Ju1-1012:13:07
��� 9 Right-SuRe�Universal 2017 17.0.23 RSU05714 Page 2
..S wRh CBA27UHE AH's\3127C sf drawn 2-2tons.rup Calc=MJB Front Door faces: N
5335 - 8TH STREET
(813)780-0020'
CERTIFICATE OF OCCUPANCY �
I I
i
�
Address: 6503 PADEN WHEEL ST Owner: LENNAR HOMES LLC �
ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200 i
Subdiv: SILVERADO TAMPA, FL. 33607-4099 �
Parcel: 05-26-21-0070-00400-0040 Work Type: 101-NEW CONST/SFR �
Construction Type: NOT APPLICABLE ❑ Sprinklers ;
Use Classification: NOT APPLICABLE �
Permit Number: 18786
Date: 1/29/2018
�� �G�
ISSU � BY: BUILDI OFFICIAL :
WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE
GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE