HomeMy WebLinkAbout17-18877 � �
CITY OF ZEPHYRHILLS
5335-STH STREET �
; (sis)�so-oozo 18877
BUILDIf�G PERMIT SINGLE FAMILY RESIDEiVTIAL �
� PERMIT INFORMATION � LOCATION INFORMATION
Permit#:18877 Issued: 10/30/2017 Address: 3185 MOULDEN HOLLOW DR
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 343,131.90 Total Fees: 14,865.97 Subdivision: HIDDEN RIVER ,
Amount Paid: 14,865.97 Date Paid: 10/30/2017 Parcel Number: 24-26-21-0060-00000-0370
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 400 W. CYPRESS ST STE 200 �
TAMPA, FL. 33607 TAMPA, FL. 33607 i
Phone: (813)574-5743 Lic: Phone: (813)574-5700 �
Work Desc: CONSTRUCT NEW SINGLE FAMILY 3,046 SQ FT ;
APPLICATION FEES
BUILDING FEE 1,324.40 ELECTRICAL FEE 274.50 PLUMBING FEE 183.00
MECHANICAL FEE 128.10 SEWER CONNECTION RESIDEN" 2,010.00 WATER CONNECTION RESIDENI 641.00
WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfd100% 4,828.00
SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
�
� � ,
��- t �
Ins ections Re uired
FOOTER 2ND ROUGH P UMB MIS INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC. '
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC. �
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTlON FEES: ,
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies. ;
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for '
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney�
before recording your notice of commencement." �
Complete Plans,Specifications and Must Accompany Application.All work shall be pertormed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. �
NO OCCUPANCY BEFORE C.O. I
I
i
i
CONTRACTO SIGNATURE PERMIT OFFI
PER IT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
O
) _V ��I```� '�
y�I�1.O-Alllfl,. I
' ., --�i`.�+ i
`fs�: �
y � .
City of Zephyrhills �
BUILDING PLAN REVIEW COMMENTS
� ��� ,
Contractor/Homeowner:
Date Received: r 2�?� 7 -��'�
Site:
Permit Type: 1 � l ���� � � ;
Approved w/no comments:❑ Approved w/the below comments: �� Denied w/the below comments: ❑
i
_ S.� S j,,�� i
�� � �
, ;
I%
�
�
This comment sheet shall be kept with the permit and/or plans. i
_ � _�.�
Kalv n rtz —Plans Examiner Date Contract and/or Homeowner
(Requ' ed when comments are present)
�
, ,. • i
PA5C0 COUNTY '
P/� C � ° "` DEVELOPMEN7 SERVICES �
l 1►.J � .,+' � 8731 Citizens Drive Dete:2/14/2018 i
�UUNTY FLOI2ID���� New Pott Richey,FL 34654
t�rs:;•�5i>.u�.L'anunr�-r Ji�,�es. 727-847-2411 I
** I��T e� �'EF�6i�l�" ��
Receipt#: 1737953 ,
FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE i
tmpact Fee Residential Solid 24503100-329010 4.00 1320005 $2'18.96 $218.96 1737953 2/14/18 '
Waste Singfe Family �
TOTALS: $218.96 $218.96 +
I
�eceiot# Paid B Chec CC Auth# Cashier ID Workstation Receiot bate Amt Paid
1737953 Check 11889 540 BCCCP06W 02/14/2018 $218.96
Total Payments: $218.96 i
1
Pa or Address Phone ' i
Lennar Homes,LLC 4600 W Cypress 5treet, 813-574-5745 ,
Suite 200 I
Tampa,FL 33607 i
i
Comments• '
City of Zephyrhills Permit#18877/18878/18879/18880.Hidden River Phase 1A PB 74 Pg101 Lot 37,38,39,40
Whlle yau will 6e peylne your blll wlth Pasco County developmentServims,the(ull amount of the eredlt card or e<keck ket,NOTshown above,Is wllected by �
Flrst 81111ny payme�tseMaes. I
i
�
I
�
I
I
MyReports/reports//PRODUCTIO.N/PASCO/ReceiptPOS VS.rpt 2/14/2018 Page 1 of 1 ,
CITY OF / / � / BUILDIN�
tEPHYRHILL3 DEPARTMENT
OF ADDITION OR COi�RECTION �
� • • - s
ADDRESS S �gv I�� ' �� DAT� I PERMIT�. ���
� �
�� ' �
THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be mode before the job �
will be accepted.
�- , ��J�I�P
� D�'i�
� i
, i
It is unlawFul tor any Carpenter,contractor,aui�der,or other persons,to AFTER CORRECTIONS ARE MADE CALL
cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-INSPECTION
or other material,until the proper inspector has had ample time to approve
the installation.
OFFICE HOURS 7.30AM-4.30 PM MON-FRI. INSPECTOR
�
�
� C , � Ashley Chenoweth (FATHOM) �
� i
�-- --' fVov 16, 1 0�31 AM MST • �
i
Good morning,Jacqueline. Our GIS team was unable to find any information to indicate where �
�
the street (Moulden Hollow Dr) is located. They have added this account to our GIS database, �
but the location is only estimated until we can obtain more information and accurately map it. �
To assist, can you please provide the field coordinate data (latitude/longitude), a map of the �
subdivision or as build engineering plans? Any of these three would be great. Please let us �
know if there are any questions. Thank you in advance! i
Best Regards, � �
Ashley � Sr Client Support Manager
FATHOM Support
� �- ; Jacqueline Boges �
� -�� Nov 13, G�12 AM MST '
,
Thank you '
.. ;.
� :--; �
f __� ; Nichole Spence (FATHOM)
�
� �- -�' �Jov 9, 6�23 PM MST �
Account # 889145-2853534 has been created, service order to follow once mapping has been�
completed. i
Best Regards, �
Nichole � FATHOM Support '
. `l � ,
r � I � I
( . � ; )acqueline Boges � , �i� 6 Z
l --' fi �Q� /
Oct 31 , 6•4G AM MST �� .,/. � ��
�._-- ?� �
�
3 �
1 �
� �
service new home 3185 moulden hollow dr �j
r
i
- - - . . _ --- - - � - - - - - - - -- - - - - - - --- -- - I
This email is a service from FATHOM. �
2 �
i
I
i
� Jacqueline Boges �
From: FATHOM <support@gwfathom.zendesk.com> j
Sent: Wednesday, November 22, 2017 3:02 PM ,
To: Jacqueline Boges �
Subject: Request#174054: How would you rate the support you received? ,
I
##- Please type yaur repiy above this line -## I
�
Hello Jacqueline Boges, i
I
We'd love to hear what you think of our customer service. Please take a moment to answer one simple question by
clicking either link below:
How would you rate the support you received? �
Good. I'm satisfied
!
Bad, I'm unsatisfied i
Here's a reminder of what your ticket was about:
I
l�
� ' Holly Zaragoza (FATHOM) ,
Nov 21, 12•57 PM MST �
i
New meter SO has been created. �
�
Best Regards,
Holly � Client Support Manager �
FATHOM Support '
�
! , ' Ashley Chenoweth (FATHOM) �
, - � �
� �- - �` iVov 1 7, 1 40 PM MST i
I
Information has been received by GIS to accurately map this location. Nichole, please proceed I
with next steps. �
Best Regards,
Ashley � Sr Client Support Manager
FATHOM Support
1
i
I
' Jacqueline Boges
From: FATHOM <support@gwfathom.zendesk.com> ,
Sent: Tuesday, October 31, 2017 9:46 AM �
To: Jacqueline Boges ;
Subject: [Request received] 3185 Moulden Hollow Dr
I
##- Please type your reply above this line -## �
Hello Jacqueline Boges, �
i
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep '
you updated on the progress of your request.
Best Regards, �
FATHOM Support Team '
TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below:
https://gwfathom.zendesk.com/hc/reauests/174054
r Jacqueline Boges ,
�-�---� Oct 31 , 6 46 AM MST
I
service new home 3185 moulden hoilow dr �
-- - ---- - i
This email is a service from FATHOM.
I
�
I
�
�
I
1
_ �
-- ,. ; .
— _....._. �. .
__ -.t _ : ;:
. . i.- �;
- - =r� =
� . .,���::!
� � � � � , � �i�ii��iiiii�i«���iii i��ii������i��i ii�ii��«<»�i����i it�� � .. ,- :=;:t.�
- 20171626@7 . -
Rcpt:1901779 Rec:
10.00 ' � '( ,
DS; 0.00 IT: 0.00
1011612017 K. M. , Dpty Clerk '
. . - .? �
� _ , , � • a�
,. , , , .. - .i'
� � � pvyo . .. �� ,
. ,
Pesmit No. Parcel IQ No 24 26-21-D80'0-OOp00-0370 ' .' ,
. i ,
` ., , . i:" -
_ ,. , � NOTiCE OF COMMENCEMENT . , ;:�'-,`-��...�
. stat�or Florida Counfy of F'asco � ' , -� •-
_ � ; .<,�,
` - THE tJNDERSIGNED hereby gives notice that improvement wi(i be made to certaln reai property;and in accordance with Chapter 713,,Florida Btatutes,'. �, �;
the foi{owing information'ss psovided in this Notice of Gommencement: � '• :
• 1. Description of Properfy� Legal HIDD�N RIVER PNASE ONE A PS PG LOT 37 �"_ ;`
� � st«�t a a aj�s M o u l d e n H o!!o w D r i v e Ze phryhi!!s F� 3354Q. � , �
.�
2. Ge�erai Description of impravement Single Family Residence/Pool!Scree�Enclosure/Fence � :
PAULp S.0'NEIL,Ph D PRSCO CLERK & COMPTROLLER%
' � 10I16/2017 03:52 m 1 af�1 � �� •
3. ' Q w n e r I n f o r m a t i o n: Lennar Homes, L�C. OR BK '���� PG ���� ' :
Natne ,
46Q�W Cy.�ress St Ste 2Q0 Tam a�a FL. 33607_,; .
Address Gity State ,
lnterest in Property: � .. —
� , ,
, � Name.of Fee Simple Titleholder• NjA `
� (!f other than owner) ` „ '
Address Gity � State '
� a. contractor� Lennar Nomes LLC � �
• Name � �
4600 W Cypress St, Ste 200 Tampa FL,33607 � '`-
-� , Address City � � State - ; �
� Contractor's Telephone No.: 813.574.5700
." 5. surety N�/4 ` _,
� Name -
., Address City State , ' ,
- Amount of Bond: $ Telephane No.: -
s: Lentfer N�A '� . �
- Narrie � .
, . . ;,. . -
' � Address City _ State � : : � •
'� Lender's Telepha�e No.: � �
� 7 Persons within the State of Florida designated by the,owr�er upon whom natices or other documer�ts rtiay be served.as provided.by � �
Section 713.13{1){a)(7),Florida Statutes: , � • `
. Lennar Homes LLC - � � "
` Name , - � ' ,
� ,, 4600 W Cvpress St, Ste 200 Tampa FL, 33607` ` -
Address City State
� Telephone N�mber af Desigrtated Person: ��3.574.5700 , , �,
_ 8. � � Iri addition to himself;the owner designates N/R qf I. ��` ' ,
" to receive a copy of the Lienor's Notice as proJided in Section 713.13(1)(b),Flarida Statutes. _, . ��
• 7elephone Number of Person or Erttity Designated by Owner: -
;.
. ,
� 9. Expiratian date of Notice of Commencement is one year from khe dafe of recording uniess a differenf date is specified: �
' WARNING TO OWNER: ANY PAYMENTS MADE BY THE QWNER AFTER THE EXPlRATI4N OF THE NQTICE OF COMMENCEMENT
� . ARE CONSIDERED IMPROPER PAYMENTS UNDER 'CHAPTER 713, PART 1, SECTION 713.13, FLQRIDA 5TATU7ES,_ANQ CRN
� � RESULT IN Y�UR PAYWG TW(CE FOR IMPROVEMENTS TO YdUR PROPERTY A NOTICE OF CQMMENCEMENT MUST BE`
� REGQRDED AND POS`i'Eb ON THE J08 SiTE BEFORE THE FfRST INSPECTtdN. (F YOU INTEND TO OBTAIN FINANCING,CONBULT � ,
` WlTH`lQIJR LENdER OR AN ATCOF2NEY BEFORE GC}MNiENCING WORK OR RECOF2DiNG YOUR NOTICE OF COMMENCEMENT;
STATE QF FLORlDA - �� � - '
C�UNTY OF PlNELLAS � -
' Signature of 4wner or Owner's Authorized OfficertDirectortPartnedManager � � " -:.
, . ; ._
�� , Vice President '� � -
� Signatory's TitlelOfflce � ' . "
- The foregoing instrument was acknowledged before me this 8 day of March r.��l7 ,by - ; .
- Steve Robert Smith as Vice President � _,. �
` (type of authori cer;irustee,attarney in fact)for
� Lentt�i'Hai7les LLC ' (name of p on be o om instrument was executed).
Personally Known�dR Produced identificafion[� Notery S' ature . � � i'
Type of ldentification Producsd Name rin Holleran ; � . �
Verification pursuant to Sectian 92.525,Florida Statutes. Under penalties oi perjury,i deciare that 1 have read ttte foregoing and fhat the facts�stated in
It are true to the best of my knowledge and belief. - , ; - . ",
' � ��n rr""�"'*"�n'�n�"�rri�rr �� . . _ � . . _
,��, ELISSAM�HOLLERAN ature of N ral Person Signing Above . -
- � =�r��.�C�mmUslon�FF88bB3T , ' - `
'"-Ex�ires June B,2020
� wpdata/bcs/bcs form; ��O�� '° DondNThNTroyFolnl�unnoatQ4aA5d0yQ �
STATE OF FLORI�A,COUNTY OF PASCO
THIS I�TO CERTIFY THAT THE FOREGOING IS A _
1'RUE AND CORRECT COPY OF THE QOCUMENT
� ON FILE 0�OF �'UBLIC RECQRD IN THIS OFFICE � � ' o����
WITNESS NlY NAN{�AND OFFICIAL SEA��f�
�_DAY OF � � ��,� � �v�,
PAULA S O'-NEI ,C� R K&C O M P T R O L L E R e
�' �`�x.:�'�,�• � �
BY _DEPUTY CLERK �Y t '
�,�.uct m
�`o G����� �
�� � \� • �
� ��
� `�'.�.,AB a ��'
�A � �
�������
�
, ' Lennar Homes-3185 Moulden Hollow Dr 3,046 sq ft
I
�
o umn � �
SQ. FEET PRICE I
MAIN OR LIVING: 3,046 $ 112.65 i
OTHER AREA UNDER ROOF: - $ 88.00 �
I
OTHER: - $ -
� I
VALUATION $ 343,131.90
FEE SHEET $ 1,220.00 ;
ADDRESS $ 40.00
� DRIVEWAY $ 40.00 �
BUILDING: $ 1,324.40 �
�
. ELECTRICAL: $ 274.50 j
PLUMBING: $ 183.00 �
MECHANICAL: $ 128.10 !
SUB-TOTAL $ 1,910.00 �
TOTAL $ 1,910.00
SEWER: $ 2,010.00
� WATER: $ 641.00 �
IRRIGATION: $ - �,
TOTAL: $ 2,651.00 �
�
WATER METER: $ 473.78 �
IRRIGATION METER $ - '
FIRE DEPARTMENT FEES " I
PLANS TOTAL: n/a �
INSPECTION TOTAL: '
PERMIT TOTAL I
TOTAL: $ - ;
PUBLIC SAFETY IMPACT FEES I
I
POLICE $ 254.00 i
FIRE $ 273.00 �
5% $ 26.35 �
TOTAL: $ 553.35 �
• SUB-TOTAL $ �5,588.13 �
. i
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28 ;
T I F'S: $ 3,632.00 i
99% $ 3,595.68 �
1% $ 36.32 �
�
- TOTAL: $ 14,865.97 !
I - - -- _ � �
s�aaao-oo2o City of Zephyrhilis Permit Application Fax-813-Z80-0021
� Building Department"
Date Received � 813 363 __ 2891
Phone Con acY t.for Permittin '
Owner's Name Lennar Homes,LLC Owner Phone Number g13.574.5700
Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number
Fee Simple Titleholder Name N�A Owner Phone Number
Fee Simple Titleholder Address N�A '
,
JOB ADDRESS Moulden Hollow Drive Zephryhills 33540 LOT# 0370 �,`
SUBDIVISION Hidden River Phase One A pARCEL ID# 24-26-21-0000-00000-0370 t�
(OBTAINED FROM PROPERTY TAX NOTICE) � ;
WORK PROPOSED II./ II NEW CONSTR 8 ADD/ALT 0 SIGN 0 0 DEMOLISH � /
� INSTALL REPAIR %
,
PROPOSED USE � SFR 0 COMM � OTHER �
Tl(PE OF CONSTRUCTION � BLOCK Q FRAME 0 STEEL 0
�
�
DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence
BUILDING SIZE U/R SF 3046 SQ FOOTAGE 2584 HEIGHT 2 StOry �f
T�TI"fTTT�TT��R'T'TTrTrTITr ,
�BUILDING $ I VALUATION OF TOTAL CONSTRUCTION
� . l Q�
, I�/ 'ELECTRICAL $ � PROGRESSENERGY Q W.R.E.C.
'� ` AMP SERVICE �
�PLUMBING $ i ;
���/ �MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION � /�� �� ,
, • � �
l
OGAS � ROOFING Q SPECIALTY � OTHER , I
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA �YES �O
1�I �I
��:--ri--F�I--�H�1-1--1-F'1--1--F-:--FC--r�I--F-4-��1--1--f-1--1--4-4�f--��1�-1--F-f--1-1--��{-��1--F-�6�1--1-�:--�:--�--FF i
BUILDER COMPANY Lennar Homes,LLC j
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N '
Address 4600 W.Cypress St.Ste.200,Ta pa,FL 33607 License# CGC1518166
ELECTRICIAN COMPANY Edmonson Electric, �IIC.
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 1034 Skipper Road,Tampa, FL 33613 �icense# EC13005408
PLUMBER COMPANY gajronet Plumbing, Heating & AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address P.O Box 5308, Bayonet, FL 34674-5308 �icense# CFC042998
MECHANICAL COMPANY gayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
,4ddress P.O. Box 5308, Bayonet, FL 346 4-5308 �icense# CAC058062
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
,4ddress 4211 Shoal Line Blvd, Spring Hill, FL 34607 �icense# CCC057991
� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � i � � � � � � � � � � � � � � � � � � � � � � � � � t � � � �
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
"**'PROPERTY SURVEY required for all NEW construction.
•���:-^�.�. . ......��„�^• • I..�f-1�-�..1..4�I..����f.�{-I..����f..��1..4�4.i-1..1-1-.1-�-�1..1-1-��{..1..��1..4.�4�1..1�-4.
Directions:
Fill out application completely
Owner&Contractor sign back.of application,notarized �
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) �
"` Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same �
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(PIoUSurvey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
►''� _ _
MOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with`any
applicable deed restrictions.
UNLICENSED COfVTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. .If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the�
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting_privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES� The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of i
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or �
final power release, the fees must be paid prior to permit issuance Furthermore, if Pasco County Water/Sewer Impact I
_ fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
` CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended)� If valuation of work is$2,500 00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
, Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
I other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner"prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that�I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to
- - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks. �
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone"V" unless expressly permitted
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer ,
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will��not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1) �
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or '
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
' the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned.
/ WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT Ifd YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FIIdANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NO ICE OF COMMENCEMENT.
FLORIDA JURAT(F.S.117.03)
OWNER OR AGENT ' CONTRACTOR
(- Subscribed and swom to(or affirmed)before me is Subscribed and swom or affirmed)before me this _
ua-Hug-i i by paul Sweene OB-Aug-17 by Paul weene
Who is/are personally known to me or Who is/are ersonall kn wn to me or - �
� ation. as identification.
L� Notary Public Notary Public
Commission No FF98537 Commission No. FF98537
Elissa M.Holleran Elissa M.Holleran
Name of Notarv tvped,orinted or stamqed Name of Notary typed,printed or stamped
- ___ _ _...._ ..
,� x,,� �RI6�#il�.N�IX�}1
� � ��I��h.H.���IE�FI
� G1t��tidt"���Mp��6d@P7
., � •c�Irtti['sltS9tl;MPf�9�l09]`
� r`'�+��ir��t�t��'��k�Q
��ky���_°uke��,��� �,�, ��aai+lat�3T,a�r�t�acn���tae��It
�.�., r �,i.ii+i e7ir�-.��#�4atn�t�t:�t;�T�ll
���__—— --- - --
� •
� , .
' � PASC4 CtaUNTY, FL�RIDA
. ,,
, f
1�� 77 ,
� `� Permtt No. �
, Date Permitted q z 9-l� "�
I
• Builder Name/Owner Name ��r ��°.�� Control# �
County Parcei No. ,Zl�-Zlo-1.1�-13OQ0�000-p 3�0 SubDiv: �Y��_�r?�C,,��� '
� Addresst�ocatlon �1�5 /j'141�-r�Pi'1 �j�OG� ��e.-
�� Glassificatfon/Type af Use �1� �_� 1�� ',
� TRAiVSPORTATtON tMPACT FEE , Rate: Sq.Ft Unit: �, lX��
i
Exempt (�Yes [] Rlo How Determined
� ' impact Fee Amount $.�J�2 3 Z� Q� Zone No. TAZ: '
I �
SCHOCIL tMPAGT F8E �
Account (056) Stngte-Family Detached tiouse Amount $ ��7 rv.Z�i
{057) Moblle Home
(058) Other Resldsntiai
123) Coltection Fee �
Exempt [(]Yes [�No How Determ(ned
I
PARKS AND RECREATION FEE �, ��
, Land Account Land Credlt Land Totat
I Recreation Account Recreatian Credit �Recreatian Totaf �
I Zone TOTAL AM�lJNl' $ `7�a�: �"�
� . . I
Exempt �Yes ❑ No How Determinad ;
LIBRARY FEE
Land Account Land Credit Land Total
Faciliry Account Facility Credit Facility Totai I
� Exempt �Yes �] Na Fiaw Determined Total AmountGF.�" �
i RESOURCEFEE ERU
TOTAL AMOUNT' '
Prepared By ^ Checked By �
`
NC1 CER71F{CATE OF OCCUPANCY WILL BE 1SSUED C1R FiNAI INSpEGTiON
PERFORMED UN31L THE T07AL AMOUNTS LISTBD HAVE
BEEN PA(D AND
RECEtPTED FOR BY A GEN7FtAL PEftMITTINC�LIFFICE OF PASCO COUNTY
Acknowiedgement betow does not!mply acceptance of concurrance,but simply recelpt of a copy of thfs form,piacing �
the buifding permft owner on notics of thls assessment and thQ conditions of paymenk for same. i
,
DATE RECE{VED BY ��
RECEIPT NO, DATE BY
, , �
. _ .. ,
i
• Moulden Hollow Dr Lot 0370 � I
� 3l
o umn
SQ. FEET PRICE �
UNDER ROOF: 3,046 $ 112.65
�
OTHER: - $ -
VALUATION $ 343,131.90 �
FEE SHEET $ 1,220.00 �
I
ADDRESS $ 40.00 I
I DRIVEWAY $ 40.00 i
BUILDING: $ 1,324.40 �
ELECTRICAL: $ 274.50 '�
PLUMBING: $ 183.00 �
MECHANICAL: $ 128.10
SUB-TOTAL $ 1,910.00
TOTAL $ 1,910.00
SEWER: $ 2,010.00 �
WATER: $ 641.00
IRRIGATION: $ - ,
TOTAL: $ 2,651.00
WATER METER: $ 473.78
IRRIGATION METER
FIRE DEPARTMENT FEES
PLANS TOTAL: �
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00 '
FIRE $ 273.00 �
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 5,588.13
PARK IMPACT FEES $ 769.56 �
SIF'S: $ 4,828.00 �
100.0% $ 4,828.00 �
1.0% $ 48.28
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00
99% $ 3,595.68 i
1% $ 36.32 '
TOTAL: $ 14,865.97
, - : i
, �
- - i
�
I
Single Family Dwelling '
Plan Review Cominents �
;
1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan.
2. Lots shall be graded to comply with R401.3 of the F.B.C. i
3. Compaction test required if 24" or more of fill dirt is brought in at any one place. '
4. Tie in survey required before pouring concrete. �
5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have ;
expansion material. ;
6. All setbacks shall be met.
7. All property markers shall be uncovered and marked at time of first inspection. '
8. All A.D.A. requirements shall be met.
9. No electric, plumbing, mechanical, or framing shall be covered without an inspection and i
approval first.
10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).
11. Appliances shall not be installed in a location where subject to mechanical damage unless
protected by approved barriers. M303.4 of the F.B.0 �
12. Water heaters shall comply with section P607.3 of the F.B.C. �
13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 �
14. Return air in all bedrooms. F.B.C. M1620.4
15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C.
16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. ;
17. All means of egress are to be in accordance with R311 of the F.B.C.
18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. ;
19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker.
20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating
or appliances or an attached garage. They shall be installed in accordance with the F.B.C.
21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all �
underground plumbing and electric. ;
22. A112008 N.E.C. Codes will be enforced. �
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0
22. In accordance with the Land Development Code, lots shall be sodded before final at least 10 �
feet around the structure.
F.F.E.-Finished Floor Elevation
F.B.C-Florida Building Code 5�'Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008)
' I
I
L � .
� _ ;
FORM R405-2014 i
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION i
Florida Department of Business and Professional Regulation - Residential Performance Method
�
� ` 0037 '
Project Name: 257561 sf ADS 2017 Builder Name: Lennar Homes �
Street: `3t�j Moulden Hollow Drive Pem,it o�ice: City of Zephyrhills ;
City,State,Zip: ,FL, Permit Numbe6rl(��i7?
Owner Lennar Homes Jurisdiction: 1 (1O
Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft' i
b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ftZ
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ftZ
4. Number of Bedrooms 4 d.N/A R= ft�
10.Ceiling Types (1489.0 sqft.) Insulation Area
- 5: Is this a worst case? _ Yes a.Under Attic(Vented) R=30.0 1489.00 ftz
6. Conditioned floor area above grade(ftz) 2582 b.N/A R= ftZ
Conditioned floor area below grade(ft2) 0 c.N/A R= ft' ;
11.Ducts R ft2
7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6
a. U-Factor• Dbl,U=0.54 71.25 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 297.8 ;
SHGC: SHGC=0.31 �
b. U-Factor Dbl,U=0.56 71.00 ftz 12•Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 �
b.Central Unit 25.2 SEER:16.00 I
c. U-Factor Dbl,U=0.56 33.33 ftz
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency i
d. U-Factor• N/A ft2 a.Electric Heat Pump 17.5 HSPF:8.50
SHGC: b.Electric Heat Pump 21.8 HSPF:8.50
Area Weighted Average Overhang Depth: 1 190 ft. �
Area Weighted Average SHGC: 0.300 14 Hot water systems i
8. FloorTypes (2582.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF 0.950
a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ftZ b. Conservation features
b.Floor Over Other Space R=0.0 1049.00 ft� None
c.other(see details) R= 440.00 ft� 15.Credits Pstat !
i
Total Proposed Modified Loads. 74.47 pASS I
Glass/Floor Area. 0.068 '
Total Baseline Loads: 74.41
I hereby certify that the plans and specifications covered by Review of the plans and ;�����'.g��, .. i I�
this calculation are in compliance with the Florida Energy specifications covered by this �, ,�� � '" w�,, p�,,, I
Code. calculation indicates com liance '�rr;r '' ,`-_'�•``' *� '
P � r ,, •,:_::Y,o``�t� r"
with the Florida Energy Code. +4 _�rarr6:�i'�•. �:r;r�r;s�ti� O '
�ave �Gol�rcG� � .f .., . � �
PREPARED BY' Before construction is completed ,w�, � �;; � �
DATE: this building�will be inspected for �ry. "•�i=�`j." - ,� �
��
�il: -
compliance with Section 553.908 * '� � - �•
I hereby certify that this bui�di��a�,s�c�����i�i�'or�1�nce Florida Statutes. �'',�, _ . ���5.- �
with the Florida Energy Coc�e. ���WE`�
OWNER/AGENT. BUILDING OFFICIAL. �
DATE: DATE. - - � '
- Compliance requires certification by the air handler nit manufacturer that the air handler closure qualifies as
certified factory-sealed in accordance with R403.2.2.1. �
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an enVefope IeaR�ge
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards,is not greater than 0.070 Qn for whole house.
8/14/2017 11:35 AM EnergyGauge�USA-FlaRes2014 Section R4�5.4.1 Compliant Software Page 1 of 5
I
I
, 1
. y
FORM R405-2014 '
I
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION '
Florida Department of Business and Professional Regulation - Residential PerFormance Method . �
;
Project Name: 257561 sf ADS 2017 Builder Name: Lennar Homes 0�37 '
Street: 3(t3�' Moulden Hollow Drive Permit o�ice: C' of Zephyrhills
City,State,Zip. ,FL, Permit Number:���77
Owner Lennar Homes Jurisdiction: 6116U1�
Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) �
1 New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area �
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2
b.Concrete Block-Int Insul,Exterior R=4 1 996.67 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft'
4. Number of Bedrooms 4 d.N/A R= ft�
5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area 2 '
a.Under Attic(Vented) R=30.0 1489.00 ft
6. Conditioned floor area above grade(ftZ) 2582 b.N/A R= ftZ
Conditioned floor area below grade(ftz) 0 c.N/A R= ft2 !
11 Ducts R ft'
7. Windows(175.6 sqft.) Description Area a.Sup.Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6
a. U-Factor. Dbl,U=0.54 71.25 ftz b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 297.8 �
SHGC: SHGC=0.31 ''
b. U-Factor Dbl,U=0.56 71.00 ft' �2•Cooling systems k6tu/hr Efficiency '
SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 ,
b.Central Unit 25.2 SEER:16.00
i c. U-Factor: Dbl,U=0.56 33.33 ft' i ,
SHGC: SHGC=0.32 13.Heating systems kBtu/hr E�ciency I
d. U-Factor N/A ftZ a.Electric Heat Pump 17.5 HSPF:8.50
SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 i
Area Weighted Average Overhang Depth: 1 190 ft.
Area Weighted Average SHGC: 0.300 14 Hot water systems '
8. Floor Types (2582.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF'0.950 i
a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ftz b. Conservation features i
b.Floor Over Other Space R=0.0 1049.00 ftZ None
c.other(see details) R= 440.00 ft' 15.Credits Pstat
1
Total Proposed Modified Loads. 74.47 � A �+�+
Glass/Floor Area: 0.068 /�-���7�7 �
Total Baseline Loads: 74 41
I hereby certify that the plans and specifications covered by Review of the plans and ��•�:$rA�•.�,., ;
this calculation are in compliance with the Florida Energy specifications covered by this �„� ,- _a .�, �}�,, ,
Code. calculation indicates compliance � r,,,r�s- r�;_�;�� �
., . ,
�•�trf;rr��"',,;.;',-.:z'',�.�'�`°�
�ave �Gal�r'cl� with the Florida Energy Code. � �,�,,,,�ti O
PREPARED BY. Before construction is completed w� • '�'� � �
this buildin will be ins ected for � � '�" r. �
i DATE: 9 P t7 ; �'�fr��:� �. . I
, compliance with Section 553.908 .�� °. �
I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. � �
Y fY 9, 9 P ��, �tij°s
with the Florida Energy Code. _ �D yyE'T�' "
OWNER/AGENT: BUILDING OFF CIAL. ,
I DATE. DATE: "" � �
' - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as -
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, ,
tested in accordance with Section 803 of RESNET Standards,is not greater than 0.070 Qn for whole house.
8l14/2017 11:35 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
� I
I � 5
FORM R405-2014 i
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method �
Project Name. 2575B1 sf ADS 2017 Builder Name: Lennar Homes ��3� i
street: 3�0 c5� Moulden Hollow Drive Permit Office: Cltv of Zephyrhills '
City,State,Zip. ,FL, Permit Number: ZFf g��J
Owner Cennar Homes Jurisdiction: 611600 �
Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2)
' 1 New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area �
a.Frame-Wood,Exterior R=11.0 1264.00 ft' �
2. Single family or multiple family Single-family b.Concrete Block-Int Insul,Exterior R=4 1 996.67 ft'
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft� j
4 Number of Bedrooms 4 d.N/A R- ft�
5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area Z i
a.Under Attic(Vented) R=30.0 1489.00 ft
6. Conditioned floor area above grade(ft2) 2582 b.N/A R= ft�
Conditioned floor area below grade(ftZ) 0 c.N/A R= ft2
11 Ducts R ft'
7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 i
a. U-Factor Dbl, U=0.54 7125 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 297.8
SHGC: SHGC=0.31
b. U-Factor• Dbl, U=0.56 71.00 ftz 12.Cooling systems kBtu/hr Efficiency �
SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00
b.Central Unit 25.2 SEER:16.00
c. U-Factor Dbl,U=0.56 33.33 ft� I
SHGC� SHGC=0.32 13.Heating systems kBtu/hr Efficiency i
d. U-Factor N/A ft2 a.Electric Heat Pump 17.5 HSPF:8.50 �
SHGC: b.Electric Heat Pump 21.8 HSPF:8.50
Area Weighted Average Overhang Depth. 1 190 ft.
Area Weighted Average SHGC: 0.300 14 Hot water systems I
8. Floor Types (2582.0 sqft.) Insulation Area a.Electric Cap:40 gallons i
EF 0.950
a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ftZ b. Conservation features �
b.Floor Over Other Space R=0.0 1049.00 ft' None �
c.other(see details) R= 440.00 ftz 15.Credits Pstat
Total Proposed Modified Loads. 74.47 pASS +
Glass/Floor Area: 0.068
Total Baseline Loads: 74.41 i
I
I hereby certify that the plans and specifications covered by Review of the plans and ��'��T',�Ir� !
this calculation are in compliance with the Florida Energy specifications covered by this ^�v • 0,�,. .
Code. calculation indicates compliance �'�/i/r��;lT� �=�w.;,.�`.t„� ;
�' t. ' •--::`�wt t"
� - �a�e ���G/. with the Florida Energy Code. �+ ��rrrrr: :���,:,;::�:�•°;.�,;,,, O
Q -'i��.' ,y i
PREPARED BY r� Before construction is completed w. - ;�'"� ;
i DATE. this building will be inspected for �. "`������ �
compliance with Section 553.908 * �'� �. � a�: ��.
I hereby certify that this building,as designed, is in compliance Florida Statutes. � " " � .
with the Florida Energy Code. CO.t?ypE"��
OWNER/AGENT: BUILDING O FICIAL.
DATE. DATE: - I
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifes as I
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage i
test report in accordance with R402.4.7.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confrming duct leakage to outdoors,
tested in accordance virith Section 803 of RESNET Standards,is not greater than 0.070 Qn for whole house. �
8/14/2017 11:35 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
� � i ��
I
I
I� --- �
r �
FORM R405-2014 '
PROJECT
Title: 2575B1 sf ADS 2017 Bedrooms: 4 Address Type. Street Address I
Building Type: User Conditioned Area. 2582 Lot#
Owner Lennar Homes Total Stories: 2 . Block/SubDivision:
#of Units: 1 Worst Case: Yes PlatBook: I
Builder Name: Lennar Homes Rotate Angle: 90 Street: J
Permit Office: Cross Ventilation: County� Pasco '
Jurisdiction: Whole House Fan: City,State,Zip:
Family Type: Single-family FL,
New/Existing: New(From Plans) I
Comment: ;
CLIMATE �
/ IECC Design Temp int Design Temp Hea'ting Design Daily Temp '
\� Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium
BLOCKS '
Number Name Area Volume ,
1 Block1 1093 9399.8
2 Block2 1489 11912
SPACES
� Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated �
1 1st Floor 1093 9399.8 Yes 0 1 Yes Yes Yes
' 2 2nd Floor 1489 11912 No 5 4 1 Yes Yes Yes
FLOORS I
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet I
1 Slab-On-Grade Edge Insulatio 1 st Floor 102 ft 0 1093 ft2 ____ 0.3 0 0.7 I
2 Raised Floor 2nd Floor ____ ___ 13 ft� 11 0 0 1 i
I
3 Floor over Garage 2nd Floor ____ __e 427 ftz 11 0.2 0 0.8
i
4 Floor Over Other Space 2nd Floor ____ ___ 1049 ftZ 0 0.2 0 0.8
ROOF �
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
U # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) i
1 Hip Composition shingles 1665 ftZ 0 ft� Medium 0.85 No 0.9 No 0 26.6 �
ATTIC �
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC �
I
1 Full attic Vented 300 1489 ftZ N N �i
8/14/2017 11:35 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 2 of 5 �
1
� �
FORM R405-2014
CEILING
�
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type �
i
1 Under Attic(Vented) 2nd Floor 30 Blown 1489 ftz 0.11 Wood !
I
WALLS � �
Adjacent Space Cavity Width Height Sheathing Framing Solar Below �
1 N=>E Exterior Concrete Block-Int Insul 1 st Floor 4 0999 19 8 8 164 7 ft2 0 0.600000 0
2 E=>S Exterior Concrete Block-Int Insul 1 st Floor 4.0999 38 8 8 329.3 ftZ 0 0.600000 0
3 S=>W Exterior Concrete Black-Int Insul 1 st Floor 4.0999 34 8 8 294.7 ft2 0 0.600000 0
- �
4 W=>N Exterior Concrete Block-Int Insul 1 st Floor 4.0999 18 8 8 156.0 ftz 0 0.600000 0
- i
_5 N=>E Garage Frame-Wood 1st Floor 11 20 8 S 173.3 ftZ 0 0.01 0
_6 W=>N Garage Frame-Wood 1st Floor 11 20 8 8 8 179.1 ft2 0 0.01 0
7 N=>E Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ftz 0 0.600000 0
8 E=>S Exterior Frame-Wood 2nd Floor 11 39 8 312.0 ftZ 0 0.6 0 �
_ 9 S=>W Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ftZ 0 0.600000 0 i
I
10 W=>N Exterior Frame-Wood 2nd Floor 11 39 8 0 312.0 ft2 0 0.600000 0
11 S=>W Exterior Concrete Block-Int Insul 1 st Floor 4.0999 6 8 8 52.0 ft2 0 0.600000 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area I
Ft In Ft In
1 N=>E Insulated 1st Floor None .2 3 6 8 20 ft2
2 N=>E Wood 1st Floor None .4 2 8 6 8 17.8 ftz
WINDOWS �
Orientation shown is the entered orientation(_>)chan ed to Worst Case.
/ Wall Overhang ;
\� # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening i
3 S=>W 11 Metal Low-E Double Yes 0.56 0.32 33.3 ft� 2 ft 0 in 0 ft 6 in Drapes/blinds None I
4 S=>W 3 Metal Low-E Double Yes 0.54 0.31 9.3 ft= 1 ft 0 in 10 ft 0 in Drapes/blinds None I
5 N=>E 7 Metal Low-E Double Yes 0.56 0.28 16.0 ftZ 1 ft 0 in 0 ft 6 in Drapes/blinds None
6 S=>W 9 Metal Low-E Double Yes 0.54 0.31 23.0 ft� 1 ft 0 in 0 ft 6 in Drapes/blinds None
7 W=>N 10 Metal Low-E Double Yes 0.54 0.31 16.0 ft� 1 ft 0 in 0 ft 6 in Drapes/blinds None
8 N=>E 7 Metal Low-E Double Yes 0.56 0.28 16.0 ft' 1 ft 0 in 0 ft 6 in Drapes/blinds None
9 S=>W 3 Metal Low-E Double Yes 0.54 0.31 23.0 ft' 1 ft 0 in 10 ft 0 in Drapes/blinds None
10 N=>E 1 Metal Low-E Double Yes 0.56 0.28 23.0 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None �
11 N=>E 7 Metal Low-E Double Yes 0.56 0.28 16.0 ft� 1 ft 0 in 3 ft 5 in Drapes/blinds None �
GARAGE .
# FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation �
1 427 ft� 427 ft2 41 ft 8.6 ft 1
I
8/14/2017 11:35 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 i
�
I I
� � i
FORM R405-2014 �
INFILTRATION �
I
# Scape Method SLA CFM 50 ELA EqLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000367 2486.4 136.5 . 256.71 .339 7 J
HEATING SYSTEM �
# System Type Subtype E�ciency Capacity Block Ducts ,
1 Electric Heat Pump None HSPF:8.5 17.5 kBtu/hr 1 sys#1
2 Electric Heat Pump None HSPF:8.5 21.8 kBtu/hr 2 sys#2
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER:16 18 kBtu/hr 540 cfm 0.85 1 sys#1
2 Centrel Unit Split SEER:16 25.2 kBtu/hr 756 cfm 0.85 2 sys#2 I
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation �
1 Electric None Garage 0.95 40 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM � �
FSEC Collector StoFage �
Cert # Company Name System Model# Collector Model# Area Volume FEF �
None None ft'
DUCTS
I
� —Supply— --Retum— Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 218.6 ft 2nd Floor 54.6 ft� Proposed Qn 2nd Floor —cfm 76.5 cfm 0.07 0.60 1 1 I
2 Attic 6 297.8 ft 2nd Floor 74.55 ft Proposed Qn 2nd Floor —cfm 104.2 cfm 0.07 0.60 2 2
TEMPERATURES
Programable Thermostat:Y Ceiling Fans: �
Coolin Jan [ ]Feb [ ]Mar [ ]A r Ma [X]Jun Jul [X]Au [X]Se [ ]Oct [ ]Nov [ Dec
Heating �Jan [X]Feb [X]Mar [ ]APr f �May [ ]Jun ��Jul [ ]Aug [ ]SeP [ ]Oct [X]Nov [X�Dec �
Ventin Jan [ ]Feb [X]Mar [X]A r [ Ma [ ]Jun Jul [ ]Au [ ]Se [X]Oct [X]Nov [ ]Dec
I
�
I
8/14/2017 11:35 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 '
: �
FORM R405-2014
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4' 5 6 7 8 9 10 11 12 �
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 �
PM 80 80 78 78 78 78 78 78 78 ' 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(UVD) AM 66- 66 .�, 66 66 66 68 68 68 68 68 68 68 �
' PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66 '
'
I I
I
1
i I
�
I
8/14/2017 11:35 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
�
I ,
I
r �
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL) �
DISPLAY CARD !
�
ESTIMATED ENERGY PERFORA/IANCE INDEX* = 100
, The lower the EnergyPerformance Index, the more efficient the home. ' '
„ FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area ,
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ftZ
b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ftz
4 Number of Bedrooms 4 d.N/A R= ftZ !
10.Ceiling Types Insulation Area ,
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1489.00 ft�
6. Conditioned floor area(ftZ) 2582 b.N/A R= ftZ ,
7 Windows'* Description Area c.N/A R= ftZ2
a. U-Factor Dbl,U=0.54 71.25 ft2 11 Ducts R ft
a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6
SHGC: SHGC=0.31 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 297.8
b. U-Factor Dbl,U=0.56 71.00 ft2
� SHGC: SHGC=0.28 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: Dbl,U=0.56 33.33 ftZ a.Central Unit 18.0 SEER:16.00 ,
SHGC: SHGC=0.32 b.Central Unit 25.2 SEER:16.00 I
� d. U-Factor N/A ftZ 13.Heating systems kBtu/hr Efficiency �
SHGC: a.Electric Heat Pump 17.5 HSPF:8.50
Area Weighted Average Overhang Depth: 1.190 ft. b.Electric Heat Pump 21.8 HSPF:8.50 �
Area Weighted Average SHGC: 0.300
8. Floor Types Insulation Area 14.Hot water systems Cap:40 gallons I
a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft' a.Electric EF�0.95 '
b.Floor Over Other Space R=0.0 1049.00 ftz
c.other(see details) R= 440.00 ft� b. Conservation features �I
None
15.Credits Pstat �
I certify that this home has complied with the Florida Energy Efficiency Code for Building ;�����;
Construction through the above energy saving features which will be installed (or exceeded) ,�,�� -:_ `��`Fo, .
in this home before final inspection. Otherwise, a new EPL Display Card will be completed � �w�', - =_='��, �
�s: ui, ?5�,a�6µ�;. t'
based on installed Code compliant features. � nr��,,��%��: ;;';°a°;..��w,t o
�:� ::�
"N'. ._..:�F=l.. ..._ �
Builder Signature: Date: 0815/17 '�� }_�:' � ° �,� �
* �.n � � '
Address of New Home: o den Hollow Drive City/FL Zip. Zephyrhills, FL 33540 ��� .:. ���`�,: !
. D yV�. �
_ *Note: This is not a Building Energy R ting. If your Index is below 70, your home may qualify for energy efficient �
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. ConXact the EnergyGauge Hotline at(321) �
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For �
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support �
staff. , j
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. ' _
8/14/2017 11:36 AM EnergyGauge�USA-FlaRes2014 -Section R405.4 1 Compliant Software Page 1 of 1
1
,,
I
�
� i i
• • �
Buildin Anal $�Sii Job: 25T5Bsf ADS ;
� � Date: 8l1412017 f
lawer flaor By: Dave i
Bayonet Plumbing Heating and Air
' s • o
For Lennar Homes ,
�
i - • e • e .
�acation: lndaor: Heating Cooling �
Tampa International AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD (°F) 39 16 ,
Gatitude: 28°N Relative hum�dity{%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/1b) 34.7 54.7 '
Dry bulb{°F) 31 91 Infiltration: '
Da�ly range(�F} - 'f4 { L } Method Simplified ;
Wet bulb(°F) - Tl Construction quality Semi-tight �
Wind speed (mph) 15.0 7 5 Fireplaces 0 1
e �
Camponent BtuhlftZ Btuh % af laad �
Walls 5.5 5191 31.9 °�S i
Glclzing 30.2 2683 16.5 �ns�uat�on '
Doars 2'[.2 432 2.7 wa'�S ;
Ceilings 1.7 60 0.4
Floors 4.1 4478 27.5
Irtfiltration 1.9 2039 12.5 �
Ducts 1400 8.6 �., �
Piping 0 0 �' F�oa� �
Hum�dificafian Q 0 ��a��s �
Ventilation 0 6 oao� Otfiar
Adjustments 0
Tata[ 16284 104.4
• s •
Component Btuh/ft� Btuh % af load ,
Walls 2.8 2641 18.9 �
Glazing 56.3 5004 35.8 W�'��S
Doars 16.6 33$ - 2.4 Intemal Gains
Ceilings 2.0 67 Q.5 '
Floors 0 0 0 f �
tnfiltration 4.4 454 3.3 {
Q ucts 'f 655 1'(.8
Ventilation 0 0
lnternal gains 3805 27.2 oucts �
Blower 0 4 Giazing �
Adjustments 0 Othe���tion i
Tota! 13965 100.0 C�oors
I
Latent Cooling Load= 1937 Btuh I
Overall U-value= 0.150 BtuhlftZ-°F �
Data entries checked. �
I
_.°--�,,, Wr'1 �"ItSO'�` 2077-Aug-14 11:39:23
�. � g Right-SuRe�Universal 2017 17.0.23 RSU05714 py9e� �
� .A27UNE AN's125758 sf ADS temptate i.5-2 ton.rup Calc=MJ8 Front Door faces:5E
11
;
�
. Y I
Buildin Anal SIS Job: 2575Bsf ADS �
� Y Date: 8l94l2077
upper floar By: Dave
Bayonet Plumbing Heating and Air
'
i
` a • s
For. Lennar Nomes �
■ - e s • �
Lacatian. Indoar: Heating Cooling �
' Tampa International AP, FL, US Indoor temperature(°F) 70 75 '
Elevation: 10 ft Design TD (°F) 39 16 �
I.atitucie: 2$°N Relative humid'Ety{°lo} 50 50 +
Outdoor: Neating Coo(ing Moisture difference(grllb} 34.7 54.7 ,
Dry bulb(°F) 31 91 Infiltration: �
Daily range{°F} - 14 ( L } Mefhad Simplified ;
Wet bulb(°F) - 77 Construction quality Semi-tight ,
Wind speed(mph) 15.0 7 5 Fireplaces 0
s �
�
Companent Btuhtft2 Btuh % of load �
Walls 3.8 4204 32.8 ��u �
Glazing 30.2 2608 20.3
dOOCS Q Q (} Walt j
Celllllgs 1.3 1868 14,6 nfiltration '
F�OOfS � a � �
In#iitratian 19 2299 17.9 ,
Ducts 1846 14.4 �
Piping 0 0 �
Elumidificatian 0 0 c�a��,�s
�811f1�8t1011 � (� Glazmg �
Adjustments 0 �
Tatal 12825 100.0
♦ s e
Component Stuh/ftZ Btuh % af load • I,
Walis 2.7 3035 16.5 Wa�is j
Glazing 52.9 4568 24.8
DOp1'S Q 0 0 Internal Gains '
Ceilings 1.7 2583 94.0 a
Floors 0 0 0 ' j
In�ltration 0.4 512 2,8 �
Ducts 2137 11.6 �
Ventilation 0 0 �lazing �
lnternal gains 5615 30.4 � � �
Blower 4 0 Ducts
Adjustments O Infiltration I
Tota! 18450 100.0 Ceilings
�
Latent Cooling Load= 3541 Btuh i
Overa!! U-value= 0.083 Btuh/ftz-°F
Data entries checked. �
2017-Aug-14 11:39:23 ,
�� wrightsoft6 Right-Suife�Universa12017 77.023 RSU05714 page 2
...A27UHE AH"s125758 sf ADS temptate 1.5-2 ton.cup Catc=MJ8 Front Doar faces:SE
I
, (
i
�
. .' �
Pro ect Summa Job: 2575B sf ADS i
J � Date: 8/14/2017
lower floor By: Dave
Bayonet Plumbing Heating and Air I
i
- a . . '
- For• Lennar Homes
Notes� ,
I
� 0 • •
Weather: Tampa International AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 °F - Outside db 91 °F
Inside db 70 °F Inside db 75 �F
Design TD 39 °F Design TD 16 °F
Daily range � ,
Relative humidity 50 %
Moisture difference 55 gr/Ib j
Heating Summary Sensible Cooling Equipment Load Sizing �
Structure 14883 Btuh Structure 12310 Btuh �
Ducts 1400 Btuh Ducts 1655 Btuh !
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh ,
(none) (none) �,
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 16284 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00 �
Infiltration Equipment sensible load 13965 Btuh
i,
Method Simplified Latent Cooling Equipment Load Sizing �
Construction quality Semi-tight
Fireplaces 0 Structure 1642 Btuh
Ducts 294 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling (none)
Area(ftz) 1093 1093 Equipment latent load 1937 Btuh
Volume(ft') 9654 9654 �
Air changes/hour 0.29 0.16 Equipment Total Load (Sen+Lat) 15901 Btuh
Equiv.AVF (cfm) 47 25 Req. total capacity at 0.85 SHR 1.4 ton '
Heating Equipment Summary Cooling Equipment Summary �
Make Lennox Make Lennox �'
Trade 14HPX SERIES Trade 14HPX SERIES '
Model 14HPX-018-230-21 Cond 14HPX-018-230-21 i
AHRI ref 10258596 Coil CBA27UHE-018-230*++TDR i
AHRI ref 10258596
Efficiency 8.5 HSPF Efficiency 13.0 EER, 16 SEER �
Heating input Sensible cooling 16915 Btuh
Heating output 17100 Btuh @ 47°F Latent cooling 2985 Btuh �
Temperature rise 26 °F Total cooling 19900 Btuh �
Actual air flow 600 cfm Actual air flow 600 cfm
Air flow factor 0.037 cfm/Btuh Air flow factor 0.043 cfm/Btuh i
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.88 �
Capacity balance point= 31 °F
Backup:
Input=4 kW, Output= 15295 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J Sth Ed.
2017-Aug-1411:39:23 ,
� '�" wrightsoftn Right-Suite�Unlversal 2017 17.0.23 RSU05714 Page 1
�� ..A27UHE AH's\2575B sf ADS template 1.52 ton.rup Calc=MJ8 Front Door faces:SE
" �
- I
i
� ' 1
Pro ect Summa Job: 25756sf ADS I
J � Date: 8/14/2017 �
upper floor By: Dave
� Bayonet Plumbing Heating and AHr
' • - e s �
i
For: Lennar Homes
N otes:
, - • s s
� Weather: Tampa International AP, FL, US fi
Winter Design Conditions Summer Design Conditions ' -
Outside db 31 °F Outside db 91 °F �
Inside db 70 °F Inside db 75 °F
Design TD 39 °F Design TD 16 °F
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 10978 Btuh Structure 16313 Btuh �
Ducts 1846 Btuh Ducts 2137 Btuh
Central vent (0 cfm) 0 Btuh Centrel vent (0 cfm) 0 Btuh I
(none) (none) ,
Humidification 0 Btuh Blower 0 Btuh ,
Piping 0 Btuh
Equipment load 12825 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 18450 Btuh �
Method simplified Latent Cooling Equipment Load Sizing �
Construction quality Semi-tight '
Fireplaces 0 Structure 3162 Btuh �i
Ducts 379 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling (none)
Area(ftz) 1489 1489 Equipment latent load 3541 Btuh
Volume(ft') 11912 11912 '
Air changes/hour 0.27 0.14 Equipment Total Load (Sen+Lat) 21991 Btuh !
Equiv.AVF (cfm) 53 29 Req. total capacity at 0.85 SHR 1.8 ton
Heating Equipment Summary Cooling Equipment Summary �
Make Lennox Make Lennox ;
Trade 14HPX SERIES Trade 14HPX'SERIES ,
Model 14HPX-024230-21 Cond 14HPX-024-230-21
AHRI ref 10258598 Coil CBA27UHE-024-230'`++TDR �
AHRI ref 10258598 �
Efficiency 8.5 HSPF Efficiency 13.5 EER, 16 SEER �
Heating input Sensible cooling 21420 Btuh
Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh I
Temperature rise 25 °F Total cooling 25200 Btuh
Actual air flow 800 cfm Actual air flow 800 cfm
Air flow factor 0.062 cfm/Btuh Air flow factor 0.043 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20 I
Space thermostat Load sensible heat ratio 0.84
Capacity balance point= 17°F �
Backup:
Input= 3 kW, Output= 11787 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. '
` �} W1'1 f1tS0'f�' 2017-Aug-1411:39:23
'1'" g Rlght-Suite�Universal 2017 17.0.23 RSU05714 Page 2 �
��` ..A27UHE AH's\25756.sf ADS template 1.52 ton.rup Calc=MJ8 Front Door faces:SE
�
I
i
i �'�
� , . �
� - I
Manual S Compliance Report �°b: 25'5BS' A°S ';
Date: 8114/2017
lower floor By: Dave
Bayonet Plumbing Heating and Air
' s - s • �
For: Lennar Homes ,
es � e • ,
Design Conditions
Outdoor design DB. 91.3°F Sensible gain: 13965 Btuh Entering coil DB. 75.g°F I
Outdoor design WB� 77.3°F Latent gain: 1937 Btuh Entering coil WB. 62.9°F �
Indoor design DB� 75.0°F Total gain: 15901 Btuh
Indoor'RH� 50% Estimated airflow� 600 cfm '
Manufacturer's Performance Data atActual Design Conditions
Equipmenttype: SpIitASHP
Manufacturer: Lennox Model: 14HPX-018-230-21+CBA27UHE-018-230*++TDR i
Actual airflow: 600 cfm
Sensible capacity� 15300 Btuh 110% of load
Latent capacity: 2700 Btuh 139% of load
Total capacity� 18000 Btuh 113% of load SHR. 85%
s o a
Design Conditions I
Outdoor design DB 30.8°F Heat loss 16284 Btuh Entering coil DB 69.6°F II
Indoor design DB: 70.0°F
{
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP " �
Manufacturer: Lennox Model: 14HPX-018-230-21+CBA27UHE-018-230"++TDR
Actual airflow� 600 cfm �
Output capacity: 17500 Btuh 107% of load Capacity balance: 31 �F '
Supplemental heat required: 0 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer Model:
Actual airflow: 600 cfm
Output capacity� 4.5 kW 94% of load Temp. rise: 50 �F
i
Meets are all requirements of ACCA Manual S. I
- �
.�, ��}} wri htsoft°' 2017-Aug-1411:39:23 �
�� '�" 9 . Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1
.A27UHE AH's\2575B sf ADS templale 1.5-2 ton.rup Calc=MJ8 Front Door faces:SE
I
. .
. , � �
� ;
' I
Manual S Compliance Report Job: 2575Bsf ADS ;
Date: 8/14/2017
upper floor By: Dave
Bayonet Plumbing Heating and Air
. �
' • - � •
� For Lennar Homes
O i � 0 • i
Design Conditions
Outdoor design DB 91.3°F Sensible gain: 18450 Btuh Entering coil DB. 75.6°F
Outdoor design WB� 77.3°F Latent gain: 3541 Btuh Entering coil WB. 62.8�F �
Indoor design DB: 75.0°F Total gain: 21991 Btuh
Indoor RH: 50% Estimated airflow: 800 cfm '
�
Manufacturers Pertormance Data atActual Design Conditions
� Equipment type: SpIitASHP
Manufacturer� Lennox Model: 14HPX-024230-21+CBA27UHE-024230*++TDR
Actual airflow� 800 cfm �
Sensible capacity: 21420 Btuh 116% of load
Latent capacity: 3780 Btuh 107% of load !
Total capacity� 25200 Btuh 115% of load SHR. 85%
j
4
o e • �
I
Design Conditions ';
Outdoor design DB: 30.8°F Heat loss 12825 Btuh Entering coil DB 69.6°F
Indoor design DB: 70.0°F
I
Manufacturer's Performance Data atActual Design Conditions ;
Equipment type: SpIitASHP �
Manufacturer: Lennox Model: 14HPX-024230-21+CBA27UHE-024230'`++TDR
Actual airtlow: 800 cfm ,
' Output capacity: 21800 Btuh 170% of load Capacity balance: 17 °F !
Supplemental heat required: 0 Btuh Economic balance: -99 °F I
Backup equipment type: Elec strip
Manufacturer Model: I
Actual airflow: 800 cfm I
Output capacity: 3.5 kW 92% of load Temp. rise: 50 °F ;
. �
Meets are all requirements of ACCA Manual S.
.� wri htsoft°� 2017-Aug-14 11:39:23 �
��� g Right-Suite�Universal 2017 17.0.23 RSU05714 Page 2
..A27UHE AH's\25756 sf ADS template 1.52 ton.rup Calc=MJS Front Door faces:SE
a •. � - -
�. . .
tis:. � � ' A
" � }'i. � 1 i�'�� a`r��� • . '� _'....,.._..... . ....... ._. �..�..����..�.�..... ��. .�
. �
., �. . .
� �.� f: � r. ' ..
�� .-
.. . .. �
� �� j .., .""_' ,. ' ' 1 D
. �, ,� •
��..r.
� ,. f �•"� � ti�• � • � ,
`• �, � �� �� : , i � !, .
��' r. ,�q, • ��. � �'�' � ,� ,'.13�
� _ � �'.'7" _� •' . � �, � �Q
� .� -� ,_ �, �,� 7�.�a : E ' r�zm
. •' ;i �-�--•——�.,.,,_�__ _� ——'l �- I ! A
' ' .> � FF EL ^�-— , -�-�,,..a,...._——.,{ �,.r..._..... ._,,._......
- . � �t� ��t� . � , � � .
' - s � � 7�.��� � � � . �
�. � � ...,�,�_�.���::� A , �fi . � � '13t�,, 7�.
.. � = s---�___-�-?`.�.'__ � . � � � , '
� : �--� �-��-�. �-� --
.. ti; �. . �.----�----�
. � �$ �� � ' , �� r�-__--_ ....�- �
' - I . 7�.�o FE�!. I � �' ..
. .�; s: � �' � A ' - �a'� ��3 • � I • °��� 7K,
. , r�_.`_^____ t � - ,T� g�� '� .. �
�, " � r�� � ---------�_-- ��� ^.,W�w�-
� 7s.�� ; # i •
�- �� �� �9 � .. � ��. � � F�
� � ' � ��. � �.�� 9� � i i � '1�8� �
• :; �.�_ __,__ � �_ : � � , �
.,..,,...,�.............�...,,.,;..,r�.................,......�..,...._.. J: �-----._ —�--� ' _=,�,---��.... ���...�,.. _�.
�: , ; I, �� ���'�t.., aa� ' ��.. . I I • � �
� �. � � '� i ' ��s : �� � i i : '��'�! �
; � �;' �..,,� ; _.�.� �, �L� �` ��''� � ' ' � �'� �
, � , — ;� ,�. .... . � _..�.�.
� : " t � - - � —�-----� , ,
� ° �. � , ��r„ t, . �� . .--t �- , Y
, �.� �r „s��'� '.��s� '_� ��a � i l • �
, . ' � � � _ .. ; ., ��� �� , � � � '���� '�
� ',. : .�- -.�- :� �, �A . � , , �,
' r i...,i.+*��s 's� : „�,�,y 4,,, �� s,. �..d�'� �
• E . : �_w��-�.�-1,..,.�,��.�..,.,,_dr,c�"�„_:
,`. . . :� , .. �.
~� � ;." j �,,. '3�" i .t� , ��. �� ��� � ��
. �: �; ;f ,,,,, `��-=.�. �a � �.� ���� �� �� � �, ��5 ; �,
, . ., L...�,�.. _�...r.�..� .� ' �, �► �� �t �
. � . , E C r+�-..n..wn�.�..�...w....v. � : f ��.,......r. ..w.�a�..,a ��.... �
'. �, .. � � • oWw....�`...d.�..,��--..n.......w4 r����� ��,.
•. • , • - � � /_��{ � ���g�. E �
5 .�� _ � •��1.I� fW�`Ri .� �LL � I . ��
� , ` , ' � I ' a.� r� r�.s� '��'� �� .� • '���! '�'�,�
. `"� �-�-— ---� �t�'' � `• � , ' •. A
� _ :y �ti_ ��
�' _.�__ -- -�-�=.�`�-�� ►�,�.�` � __ p-
� � � � �a E . � „��.��.__.� �"� _ __
� � � � � �'`'�, r.�,� � t � ., , , �
i . � . . ,._ ,.�. �. ,� � �g��a. �Q� . ! � ���,(.�'
. ' �s ; �.:�..`�'.;..,._ .r.w..,...� ,� �2.� ...r.�,„ '�l� � �
i................................. .... ... „. ..__,_ ._.. + .., . ,.,7 ; �.,,.__.�,_ I EF F.fi� �"—`-_......��.f''�"",.�.�.{l�'�..� ,._.,_--
. �:; t .�i ,�.�......_.._,.,._._.,...� �.�,..,_., ,.,__
.� � { � �� � I _ � �� � ' I � �
� , � : 1 ,� � ;� r�.�� ��� � � �.�'�,�
., �.��, __,� ;�� , � � �, , �
; , �...�_.. .......�....._—, . ��, _— .,_.,� �. ,
,� ._._....,,..
.,,' . � ��t, ' �___.r..._,_.�_.� E ���...,_� �...�
. � � �� �ax.-a.n� _ ,. ��. s ' 1 f ��
• � E q� � ^ 3 ,�a � �.� I 1 '��'� �
� � � ���.' ..,.�....�.u. ._,,. ,�'�' _ R� • �
. � ,.
.W.�
;�..... ._�._. ...,;.. _....... ....,,,. ....,.... ..�•... •..,,,.. ,-.,..,.. ., • :
L �
� .,� ����;�.�.�.�. � y..�. ��,�--��— ��''_'�.�.-�=
� r''� t� � " � � ��'�
,� �. ,., ��.�`. � � �7 . � �: �� � � ,u
� f�-' y '�� . � �` ��.. 1=' � � o�.. �'°° �05 i � �12C� �
� �� �� �1 � �� � � �'�ae� '� � ' `-„� t �
i ,.'' � ,� � : "'-- �'"�-- ` f �a'"----�,..
�'''"' t .1 ', � ` . 41 4 ' '��, '�-�,� �,�---.. �. �
, r@''� � �i � 39 �� �� � �� ... ��. E �,,....,,.,,. �..,�.,i� -��"~--.�,..,_..
'� ` . � � � �' �� �i.s� � -,.
�1 � �' l � n .. � �'' "r' ,,,,,��...... '� � �
� �� �� 1��' 't��.�$5 � 1� 'i� .. • '�,,.� ,,, , ' �,, �t�� �� � � �I�I 9 �a.
�5 � � � � � � _ .` �� , � �,,,�. a�..�
� ����.. � � '; ' '�� �;� r f'..�,�� �
� � 1 � �,� � � .. , 1 � FF Ei 1 .y,, w, / � � �.
i � A , ' � ` T1.ii� �. � ! ,� ,. `,. •
� - a � FF R � ' �A 1 �'�, �'���✓ �•, '''+�.� '�
; � �1 �` ., - " 1 �.35 � 1�' �� - ��* �}� `�° �'~ ..
� 1 . . ,. 1. .t . , 4: • `+� �'�✓'�,..�� .� a n . -� � �
i
,� ° SKETCH ONLY SEC. 24 , TWP. 26 S, RNG. 2� E.
N
PLOT PLA NOT A BOUNDARY SURVEY
LOT 37 - BEARING easis:
HIDDEN RIVER PHASE ONE A NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40'43" E
PASCO COUNTY, FLORIDA. �T THIS SURVEY IS SUBJECT TO ANY FACTS THAT
MAY BE DISCLOSED BY A FULL.AND ACCURATE
PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS 1� TITLE SEARCH. ALSO SUBJECT TO SETBACKS,
THIS PLAN IS FOR PERMITTING PURPOSES LOT =_ 9072.53 SQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD.
ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA =_ 10_9_3__SQ. FT.
ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY =_3_5 SQ. FT. M UNDERGROUND FOOTER, STEM WALL, AND
GARAGE =�42_7 __SQ. FT. II UNDERGROUND UTILITIES ARE NOT LOCATED OR
LEGEND: COVERED LANAI ==_L.A_—SQ. FT. SHOWN.
_�—►= PROPOSED DRAINAGE FLOW FATIO =__23 SQ. FT. � DO NOT SCALE THIS PRINT. DIMENSIONS AND
CONC. DRIVE =_399 SQ. FT. w
(00.00) = PROPOSED GRADE A/C & CONC PAD = 18 SQ. FT. -' NOTES TAKE PREFERENCE.
E-00.00 = EXISTING GRADE ca.�
PRIVATE SIDEWALK =�31 _SQ. FT. N DESCRIPTION NOT CONTAINING PLAT BOOK AND
NOTES' IMPERVIOUS =__?2 % PAGE INDICATES THAT PLAT IS IN
- _202_6___SQ. FT. PRELIMINARY STAGE AND IS SUBJECT TO
LOT GRADING TYPE = A SOD =_7_�47 _SQ. FT CHANGE AND/OR REVISION.
PROPOSED PAD ELEVATION =
FRONT SETBACK = 20' OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON
SIDE SETBACK = 70� ENGINEERING PLANS PROVIDED BY CLIENT.
REAR SETBACK = 10' RIGHT OF WAY = 1816_94 SQ. FT.
DRIVE APRON = 1_45 SQ. FT. STRUCTURE TIES SHOWN HEREON DENOTES �
PUBLIC SIDEWALK =_588 S0. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION
- SOD =_1_�84 SQ. FT. TO PROPERTY LINE. I
TOTALS '� = 10� DRAINAGE/UTILIIY EASEMENT I'
� AREA =_10889•47 SQ. FT.
DRIVEWAY =_5_44____SQ. FT.
I SIDEWALK = 619 _�SQ. FT. �
p�T I SOD =_S_1_31�SQ. FT.
BOUNDA, RY
�� TRACT "I"
' �BUFFER/DRAINAGE & LOT 36 A: �
I /I LANDSCAPE EASEMENT . '.
ZEPHYRHILLS COLONY COMPANY � � �_� N �
(PIAT BOOK 1, PAGE 55) o- �
r�� r�� �
3.33' ss�. -�'� S 89°36'S8" E 110.00' _�� 'ej ,;' o .
PRM(P)\ N n: O I
\ 7.00' � ;_,
TRACT "D" 1 I �
DRAINAGE & � a
p�qT� LANDSCAPE EASEMEM '� I a
U
BOUNDARY � '� a
� �''4sJ� s9'S. " I . �
:°'� I ��N 89'3,6'�8" W
� �o• 2 00
^� �^y.
p P�O I
�� ooP►� ao-o � , -
�u'. ,o�° QR�P°z oy / . / �
O�, Q���R�GN'� /� ' �
LOT 38 l-y ��. GPRp.G� �� . � : O
o, �'O . / *� t�p� v ,
� .��6��� 2 SA/ ,� ��
OO 10Oo ..h.:.�:�f/ /���\�., '
. aoo� ' O�O �
I - �� �o.�-� ':� J�
� ���' ,:��. � p
r> •�65�, �, ':���w- i � �
�9j� ..�.S r°��.��9 .�oo�,,'
, , �
- QGp�PI�—�
i
LINE BEARING DISTANCE / '
Ti N 64'36'S7" E 12.95' '
T2 N 00'23�09" E 4.38' �
PROPOSED:
CURVE RADIUS ARC CHORD BEARING DELTA LOWEST FLOOR ELEVATIONS:'
css ao.ao' as.se� as.oe� s sz•3o'o0" w ea•i3�ss�• LIVING AREA: 72.40' j
GARAGE AREA:
DESCRIPTdON: ELEVATIONS REFERENCED TO
LOT 37, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE A", NATIONAL GEODETIC VERTICAL
AS RECORDED IN PLAT BOOK 074, PAGES 101 THROUGH 121, DATUM OF 1929. MEAN SEA
OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT.
APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL N0. 120230 0460 D EFFECTIVE DATE: 9/30/1992
LEGEND:
(C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, �= CENTERLINE. A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/5=
CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, P6= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP Na. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK,
U P= UTILITY POLE. W F= WOOD FENCE R = RADIAL
JOHN R.BEACH&ASSOCIATES,INC. Drawn By: SMS Squore Feet: gC72:53 t LENNAR HOMES
� SURVEYORS AND MAPPERS Checked By: -
911 WEST ST. PETERSBURG DRIVE JRB
ONE; OLDSMAR, FLORIDA 34677 -
WAY (g�3) 854-1276 FAX (813) 855-8370 Scale: �^=30' _ - - �]. 1
NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 7 31 17 ACS �p�.(�y�GG7
THE ORIGINAL RAISED SEAL OF A FLORIDA BEACH ' DATE
LICENSED SURVEYOR AND MAPPER FLORIDA R . ND SURVEYOR No. 2984 LB 4493
�Revisions: RERVISED PER LEGAL 8/18/17 JBS -