Loading...
HomeMy WebLinkAbout17-18881 1 CITY OF ZEPHYRFIILLS ;. +� 5335-8TH STREET (sis)�so-oo20 18881 BUILDING PERMIT SINfaLE FAMILY RESIDENTIAL --- PERMIT INFORMATION LOCATION INFORMATION � Permit#:18881 Issued: 10/30/2017 Address: 3293 MOULDEN HOLLOW DR Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. ; Class of Work: 101-NEW CONST/SFR Township: Range: ' Proposed Use: NOT APPLICABLE Lot(s): Block: Section: i Sq. Feet: Est. Value: Book: Page: Cost: 267,656.40 Total Fees: 14,523.97 Subdivision: HIDDEN RIVER ; Amount Paid: 14,523.97 Date Paid: 10/30/2017 Parcel Number: 24-26-21-0000-00000-0280 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W. CYPRESS ST STE 200 � TAMPA, FL. 33607 TAMPA, FL. 33607 Phone: (813)574-5743 Lic: Phone: (813)574-5700 Work Desc: CONSTRUCT SINGLE FAMILY W/SALES OFFICE 2,376 SQ FT APPLICATION FEES PLUMBING FEE 148.80 SEWER CONNECTION RESIDEN" 2,010.00 ELECTRICAL FEE 223.20 WATER CONNECTION RESIDENI 641.00 MECHANICAL FEE 104.16 SCHOOL IMPACT FEE-sfr/100% 4,828.00 TRAFFIC IMPACT FEE 1% 36.32 TRAFFIC IMPACT FEE 99% 3,595.68 SCHOOL IMPACT FEE-sfr/1% 48.28 BUILDING FEE 1,091.84 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 ' ,, /�� I � �G , ���� �� Ins ections Re uire , FOOTER 2ND ROUGH PLUMB MIS IN LATION CEILING I FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY � PRE-SLAB SHEATHING MISC. MISC CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application. All work shall be performed in accordance ' with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. � �. CONTRACTOR SIGNATURE PERMIT OFFI PER T EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER I � Jacqueline Boges ' From: Nichole Spence(FATHOM)<support@gwfathom.zendesk.com> � Sent: Thursday, November 9, 2017 8:23 PM ; To: Jacqueline Boges � Subject: [FATHOM] Re: 3185 Moulden Hollow Dr � � i ##- Please type your reply above this line -## Your request (#174054) has been updated. REPLY TO THIS EMAIL or click the link below: https://qwfathom.zendesk.com/hc/requests/174054 ���� 9 Nichole Spence (FATHOM) (--' Nov 9, G:Z3 PM MST Account# 889145-2853534 has been created, service order to follow once mapping has been completed. Best Regards, � �� Nichole � FATHOM Support �l � � Jacqueline Boges �`�� Oct 31 , 6 4G AM MST service new home 3185 moulden hollow dr This email is a service from FATHOM. � 1 Jacqueline Boges From: Nichole Spence(FATHOM)<su ort@gwfathom.zendesk.com> Sent: Wednesday, No 2017 5:37 To: Jacqueline B ge �� ! , Subject: [FATHOM] e: 293 Moulden ollow Dr - � ���� I ##- Please type your reply above this line -## Your request (#174040) has been solved. TO REOPEN THIS REQUEST, reply to this email or click the link below: https://q wfath o m.ze n d es k.co m/h c/req u ests/174040 ` ' � Nichole Spence (FATHOM) `------�' Nov 8, 3.36 PM MST Customer Account # 0000889145-002 19324. Install s vice order# 61 5297. Best Regards, Nichole � FATHOM Support �--------; i ; Nichole Spence (FATHOM) i -�- � - �--' Nov 3, 2 1 l PM MSl- Thank you CJ, the book and cycle has been updated. A service order for meter install will be created once the account has been mapped by our GIS team. Best Regards, , , ' Nichole � FATHOM Support _ ' �'� � CJ Funnell ' I � � - - , ` --�---- Nov 1 , 4.32 AM MST , � � Hello Nichole, We would like to start a new book in C cle 1 Book 11 . Please let me know if ou have an I v v v � questions. ; Thank you for your time, C.�. Funnell 1 CITY OF / / / / BUILDING tEPHYRHILLS DEPARTMENT O� ADDlTION OR CORRECTION � • • - • ADDRESS . DATE PERMIT�, �Z`r� f�Il n��c��� , b �,� � _ 3.� � t��� THIS JOB HAS NOT BEEN COMPLETED. The following additions or correction�shall be made before the job will be accepted. ���� �i4/c,�i '-��' ��l/t- >rc� ,',� �1 `n .�' r �� It is unlawFul tor any Carpenter,Contractor,euilder,or other persons,to AFTER CORRECTIONS ARE MADE CALL _ cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-INSP CTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI INSPECTOR � Y , f� - I i Jacqueline Boges � From: FATHOM <support@gwfathom.zendesk:com> Sent: Tuesday, October 31, 2017 9:16 AM � To: Jacqueline Boges i Subject: [Request received] 3293 Moulden Hoilow Dr i � ##- Please type your reply abave this line -## i Hello Jacqueline Boges, � We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://gwfathom.zendesk.com/hc/rea uests/174040 I� � � Jacqueline Boges ' l-�T--�' Oct 31 , 6:16 A�/I MST ' service for new home located 3293 moulden hollow dr This email is a service from FATHOM. � I 1 � Lennar Homes-3293 Moulden Hollow Dr-2,376 sq ft o umn SQ. FEET PRICE ' MAIN OR LIVING: 2,376 $ 112.65 ' i � I OTHER AREA UNDER ROOF: - $ 88.00 , OTHER: - $ - � �I VALUATION $ 267,656.40 FEE SHEET $ 992.00 ' ADDRESS $ 40.00 � DRIVEINAY $ 40.00 BUILDING: $ 1,091.84 ELECTRICAL: $ 223.20 .- PLUMBING: $ 148.80 MECHANICAL: $ 104.16 SUB-TOTAL $ 1,568.00 TOTAL $ 1,568.00 SEWER: $ 2,010.00 WATER: $ 641.00 IRRIGATION: $ - TOTAL: $ 2,651.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a � INSPECTION TOTAL: PERMIT TOTAL � TOTAL: $ - i PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,246.13 � � PARK IMPACT FEES $ 769.56 � SIF'S: $ 4,828.00 ' 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,523.97" � � - - q_c•p�J o J���Dii�GH s � "�/ "�t,�,.;y.r� -�3� City of Zephyrhills BUILDING FLAN REVIEW COMMENTS Contractor/Horneowner: �,. Vt�t'' ���_ Date Received: �'�a`�( �`"�'l Site: � ' � � s �'�- �,�'��-.s t�, , �... �� � � � � � �� Permit Type: �j � L/ � �._ Approved w/no comrnents:❑ Approved w/the below carnments: � Denied w/the below comrnents: 0 "�� �Q�� This comment sheet shall be kept with the permit andfor plans. ��� ����i � Kalvin Switze — ans Examiner Date ' Contractor ar Homeowner (Required hen comments are present) - � � � I IIIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIiI lllll Ilf Il IIII�illl � : � f . 2017162605 , - . �' ',:' . , Rcpt:1901779 Rec: 10.00 " � � , , DS: 0.00 IT: 0.00 - , � 10/16/2017 K. M. , Dpty Clerk - ,. , , ' , , ��, ,.„ d v 4 e• ' ,Permit No. Parcel ID No 24-26-21-09.90-00000-0280 . � �t, " , -� -. , - - NOTICE OF COMMENCEMENT , � . State ot . FIOI"Ida county of Pasco � , , THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, : the following information is provided in this Notice of.Commencement: ' ' 1 Description.of Property: Legal HIDDEN RIVER PHASE ONE A PB PG L.OT.28 � - .( ' StreetAdd g3 Moulden Fiollow Drive Zephryhills FL 33540 ` ' . i..':' � 2. General Description of Improvement Singie Family Residence/Pool/Screen Enclosure/Fence - . . , , - , PRULA S 0'NEIL,Ph D pqSCO CLERK & COMPTROLLER - . 10/16/2017 03:.52 m 1 , of 1 ' � 3: owner Information: Lennar Homes, LLC. � OR BK ���� P� 154�� � ��-� � Name - 4600 W Cypress St..Ste 200 Tampa FL. 33607 _ � - Address ' City , ,State ' , Interest in Property: - � ,� , - Name of Fee Simple Titleholder N�A (If other than owner) - : � ' Address City State a. , contractor� _ Lennar Homes, LLC . - Name ' � 4600 W Cypress St, Ste 200 Tampa FL, 33607 _ Address City State _� ' . Contractor's Telephone No. 813 574.5700 -, . , 5. Surety� :, . N/A. ' � - Name . - Address City State Amount of Bond: $ Telephone No.. ' ' s: - �ender: N/A � Name - �� . , _ , , _ Address City . State . , ' ' Lender's Telephone No.. , . .' 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: , " Lennar Homes LLC ` ` � -� � Name - � , 4600.W CVpress St, Ste 200 Tampa FL, 33607-';,':-;,.`;;;.,�,. , Address ' City . State ''' � " ' Telephone Number of Designated Person: 813.574.5700 � . - 8.� In addition to himself,the owner designates N/A of ' , ,_ , ; '��, to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. " ' Telephone Number of Person or Entity Designated by Owner: . 9. Expi�ation date of Notice.of Commencement is one year from the date of recording unless a different date is specified: , � � . WARIVING TO OWNER:, ANY PAYMENTS MADE BY THE OWNER AFTER l'HE EXPIRATION OF THE NOTICE OF COMMENCEIVIENT ' ' ' „ , ,ARE_ CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN ' � RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE ' ' - _. RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT - _ WITH YOUR LENDER OR AN ATfORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT., � STATE OF FLORIDA ' ' .'` ,�� ', - COUNTY OF PINECLAS , • � - � _ , - ' Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager � • Vice President • , ' - , Signatory's Title/Office , • � � � - The foregoing instrument was acknowledged before me this 8 . day of March �d�7 ,by . ' SteVe RObel't Smlth as ViCe President (type of tho' ,e.g.,officer,,trustee,attorney in fact)for - Lennar Homes LLC � _ �name of p be aif ofwhom instrument was executed): • Personally Known•�OR Produced Identification❑ : Nota ignat � ' � Type of Identification Produced Name(Print) Elissa�Holleran Verification pursuant to Section 92:525,Florida 5tatutes. Under penalties of perjury, I declare ftiat I have read the foregoing and'that the facts stated in i � � it are t�ue to the best of my knowledge and belief � _ , - � �� � ; , . ;��=.ELISSAM;HpI:LERpN ' Signature of Natural Persori Signing Above :*�.,F;Gmml�elon�FF 88583r � � :�-Ex'Ua�June 6,2020 - - . , wpdata%bcs/bcsform; �'%PI�� �'�� DondMThru7myFolnln+unoa10040.5-Tp1p ���� ����� � Q� � e ~, � � �B� �1'AT��� FLCDRlDA,C�lJR1TY 0�PASCO "�-� - �° �-s�-,�'`��-. �a � � THIS IS TC�CERTIFY 7HAT THE F�REGOING IS A •����� �;� �'RUE AND CORREC7 CQRY OF THE DOCUMENT m u �'v�E�ruf m ' ON FILC Of;�F�UBLIC RE'�ORD IN THIS OFFICE � �G� °�' � k. UVITNESS MY�HA��AND p�FICIAL SEAL THIS �' ,5;x ��� �"s� �(� DAY OF � 2 '�(1 � � p8�=� PAULA S. O'i�EIL, E K&COMPTROLLER � "� �'�� �� � ,���' ������`�� BY DEPUTY CLERK , � 813-780-p020 City af Zephyrhills Permit Application Fax-813-780-0021 � Buiidi�g Deparkment - Date Received Phone Cpntact for Permittin 813 363 �� __ 2891 ' Owner's Name �ennar Homes,LLC Owner Phone Number ��3•574,5700 . _ 4600 W.Cypress St.5te.200,Tampa,FL 33607 � �� ` � owner•s Address Owner Phone Number Fee Simple Titleholder Name N�A � Owner Phone Number � � ,•, z Fee Simple Titieholder Address N/A • �� JOB ADDRESS Mdu���� HOIIOW Dt'IV� Zephryhills 3�5�� to�'# �2$� susoyv�syorv Hidden River Phase Orre A PARCE�ID# 2G�-ZF)-Z�-OOOO-OOOQQ-O�HO (OBTAINED FROM PROPER7Y TAX NOTICE) � _ -„_W_PR_K.P_Rl?POSED � -' - �/ -•NEW"GONSTR"""' DDlALT g� --SIGN � 'y � DEMOLISH � ���'Ii�ISTAGL �� REPAIR " _ PROPOSED USE � SFR Q COMM � OTHER TYPE QF CONSTRUGTION � BLOCK � FRAME � STEEt, � o�scR�Pr�aN oF wa�z� Single Pamily Residence/Poal/Screen Enclasure/Pence ��_,�_ BUILDlNG SIZE U/R SF 2�76 gQ F001'AGE �936 HEIGHT 1 Story � � �BUILDING � 4S�-'1 ��� VALUATION OF TOTAL CONSTRUCTION i.l ��/ �ELECTRICAL $ � PROGRESS ENERGY Q W.R.E.C. ' ' ` �_ � AMP SERVICE �PLUMBING � � � � � � �MECHANICAL $ VALUATION OF MECHANICAL INSTALLATIQN ''�� �GAS a ROOFING � SPECIALTY � OTHER FfNiStiED FLQOR ELEVATIONS r�� �LOOD ZONE RREA �YES �lt? L t-7 -�-�-1--1-1-�1-4-i-HI--1-1--1--E-h1--Fl-f-i--�-1-1--1--F-1-1-t--1-i-4-1-�1�-E-a-1-1-�i-�-1-1--F-1-J--1-a-1-�f-1-1-E-1--1-�--�1-1-i-1--1-F-0--F=1- BUILDER � � COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4600 W.Cypress St.Ste.200,Tam a,FL 33607 License# ��C1S18166 �� ELECTRiCIAN COMPANY Edmonsan Eiectric, 1tlC. - SIGNATURE REGISTERED Y/ N FEE CURREN Y(N ' Address 1034 Skipper Road,Tampa, FL 3 613 License# �C13005408 `� , PL.UMBER COMPANY Bayonet Plumbing, Heating &AG, Ir�c SIGNATURE REGIS7EREp Y/ N FEE CURREN Y/N Address P.Q. Box 5308, Bayonet, FL 346 4-5308 ticense# �FC042998 � IUIECHANtCAC. � _ COIUIPANY ��Y�n�t Piumbing, Heating &AC, lnc SIGPIATURE REGISTERED Y/ N FEE CURREN Y/N Address �-d• Bax 53Q$, Bayonet, FL 34 4-5308 �icense# �AG058062 � , OTHER COMPANY SIGNATURE REGISTEREp Y/ N PEE CURREN Y I N , _ - - aadress 4211 Shoa! Line�Ivd,Spring Hiil, FL 34607 License# GCCQ57991 � It � � � � � � � � � l � � � l � � � � � � � � � � 1 � � � � � � � � � � 1 � � � � � � � � � � l � � l � � � � l � � � � � � � � � � RESIDENTIAL Attach(2)Plot Plans;(2}sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new constructian, M'snimum ten{4 d}worKing days after submittai date. Required onsite,Canstruction Plans,Sfarmwater Plans wl Silt Fenee instaiied, � Sanitary Facilities&1 dumpster;Site Wark Permit for subdivisions/large projects � CCtMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10}working days after submittai date. Required onsite,Construcfion P1ans,5tormwater Plans wl Silt Fenee insta!led, � Sanitary Facilities&1 dumpster Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach{2)sets of Engineered Plans. "*`"PROPER7Y SURVEY required for aIl NEW construction. -1.�1-1..{���1-�1..{..I..1--1-1..1�.1�1..'.�'.�::..:-1..1..4.4.�f-1�1�1--1-.1..1..4.L-{.�1..1�1..1..1..1�1..4�{-{..1-1..1-I-1�.1�4�.f�f��4��{.�1-.L�.1� Directions: ' Fili ouf appiication complefely Owner&Contractor sign back of application,notarized , if over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) "" Agent(for the contractor)or Pawer of At#omey(for fhe owner)wou(d be someone with nofarized tetter from awner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroafs if shingias Sewers Service Upgrades AtC Fences(PloflSurveylFoofage} Driveways-Not over Counter if on public roadways..needs ROW iVOTICE OF DEED RESTI2ICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes respansibility far compliance with any applicable deed restricfions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILIT'IES: If the owner has hired a contractor or _ contractors to underfake work, they may be-required to be licensed in accordance with state and lacal reguiations. If the �.-� contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violatian under state law. If the owner or intended contractor are uncertain as tQ what iicensing requirements may apply for fhe infended work, fhey are advised to contact the Pasco County Bui(ding Inspection Division—Licensing Section at 727-847- 8Q09. Furthermore, if the owner has hired a contractor ar contractors, he is advised to have the contractor(s� sign portions of the�"`contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor,, that may be an indication that he is not praperly licensed and is not entitled to permitting privileges in Pasco --- County. _ TRANSPORTATION IMPACT/UTtLITtES IMPACT AND RESOURCE RECOVERY FEES. The undersigned understands that Transportation Impact F'ees and Recourse Ftecovery Fees may apply to the construction af new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County �rdinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is�further understood that 7ranspartation Impact Fees and Resour�e R��o�ery Fees must be paid'prror o - --- receiving a "certificate af occupancy" ar final pawer release. If the project d'oes not invoive a certifi,cate of occupancy or final power release, the fees must be paid prior to permit issuance Furkhermore, if Pasco County Water/Sewer Impact fees are due,they must be,paid prior to permit issuance in accordance with applicable F'asco County ardinances. CONSTRUCTION=LtEN LAW(Chapter T13, Florida Statutes, as amended}. If valuation of work is$2,500.00 or more, 1 certify that I,the applicant, have been provided with a copy of the "Florida Constructian Lien Law—Homeowner's _ Prafection Guide° prepared by the Florida Depat#men# af Agriculture and Consumer Affairs. If the applicant is someone " other than the"awner", I certify that I have obtained a copy of the above described document and pramise in good faith ta deliver it to the"owner" prior to commencement. Ct3NTRACTOR'S/OWNER'S AFFIDAVIT: I certify tha# all the information in this application is accurate and that all wark � will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to abtain a permit to da work and installation as indicated. f certi�fy thaf no wark ar insta(lation has commenced prior to issuance of a permit and that all work will be performed to meet standards af all laws regulating canstructian, County and City codes, zoning regulations, and (and development regulations in the jurisdictian. ! also `certify that 1 undersfand that the regulations of other government agencies may apply#o the intended work, and that it is my respansibility to identify what actions I must take to be in campliance. Such agencies include but are not limited to: - Department of �nvironrrtental Protectian-Cypress Bayheads, Vltetland Areas and Environmentaily Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Watsr Management District-Wells, Cypress Bayheads, 1Netland Areas, Altering Wa#ercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Flealth & Rehabilitative SsrviceslEnvironmental Nealth Unit-1Nells, Vltastewater Treatment, Septic Tanks. - US Environmental Protec#ion Agency-Asbestos abatement. � - Federaf Aviation Authority-Runways. I understand that the fallowing restrictions apply to the use of fill: - Use of fill is not a(lawed in Flood Zane"V"uNess exprassly permitted. � - lf the fill material is to be used in Flood Zone "A", it is understaod that a drainage plan addressing a . °compensating valume" wil! be submitted at time of permitting,which is prepared by a professiona! engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, 1 certify that fill will be used only to fi11 the area witt�in the stem wall. - If fill material is to be used in any area, I certify that use af such fill will not adversely affect adjacent properties. !f use of fill is found to adversely affect adjacent properties, the owner may be cited for via{ating the canditions of the building permit issued under the attached permi# application, for lats less than ane (1) acre which are elevated by fill, an engineered drainage plan is required. If 1 am the AGENT FQR THE OWNER, I promise in good faith to inform the owner af the permitting conditions set farth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the app{ication. A perrnit issued shall be construed to be a license to proceed with the work and not as autharity to vialate, cancel, a(ter, ar set aside any provisians of the technical cades, nor shall issuance of a permit prevent the Building O�cial from thereafter requiring a correction of errars in pEans, construcfian or violations of any codes. Every permit issued shall become invaEid unless the work autharized by such permit is cammenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be reguested, in writing, fram the Building OfFciai for a period not to exceed ninety (90) days and wili demonstrate jus#ifiable cause for the extension If work ceases for ninety(90) consecutive days, the jab is considered abandoned. WARNING TO OWNER: YtOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. !F YOU 1NTEND TO OBTAIN FINANCING,CONSULT 1NITH YOUR LENDER OR AN ATTORNEY BEFURE RECORDING Y UR NOTICE OF COMIVIENCEMEh[T. FLQRIDA JURAT(F.S.117.03) OWNER OF2 AGENT CONTRAG Subscribed and swarn fo(or affirmed)before me i Subscribed.and sworn to.(or_aftirmed)before me this uts-Hug-i i by p�ul Sweeney oe-Aug�17 by Paul Sweeney Who islare personally known to me or Who istare er onall known to me or as identification. as identification. %'' /'� - �-�-~'i Notary Public �--� �—'—.�� '�•— Notary Public Commissian No. FF98537 Cammission Np. FF9$537 Elissa M.Holleran Elissa M.Holleran Name of Notarv fvped,printed or stamoed Name of Nofary typed,printed or stamped _ .,.�■.�;.„„ _..,... .. .. .. �r ��:� ��1��4N.�1�I�.�t�. ,�.� , ����k'�.�f�l��hl - � �r�lte�t'�Aald�,���83? ti � ���ikTn�'�'dEt�t��Pt1�E19�` �#���.uE�r��'����d ,��'��,�r��d���� ,�����I�r,��j��i���a�t�cai�,�l1 ,` .a. �td k�&4��'P�7J2`."0��@��il.!'9�3+3M.�a^rT�b�� . . . _ . . 5�,�.�5 �-� c-e �_ _ T_- � . _ FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION � Florida Department of Business and Professional Regulation - Residential PerFormance Method Project Name: WHC 1941 sf,lot 0028 Hidden river Builder Name: Lennar Homes. OO2g Street: `�2�? Moulden Hollow Drive Permit ottice: City of Zephyrhills • � City,State,Zip: ,FL, , Permit Number � '���� _ � Owner• Lennar Hoines Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) � 1. New construction or existing Addition 9. Wall Types(353.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 241.00 ftZ b.Frame-Wood,Exterior R=11:0 112.00 ftz 3. Number of units,if multiple family 1 c.N/A R= ftZ 4 Number of Bedroom�Bedrms In Addition) 0(0) � � - "' ' ' d:N/A ' ' ' R= {�z 5. Is this a worst case? No 10.Ceiling Types (416.0 sqft.) Insulation Area Z a.Roof Deck(Unvented) R=1.0 416.00 ft 6. Conditioned floor area above grade(ft2) 416 b.N/A R= ft' Conditioned floor area below grade(ft2) 0 c.N/A R= ft' 11 Ducts - R ft2 7. Windows(0.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic . 6 83.2 a. U-Factor: N/A ftZ SHGC: b. U-Factor N/A ftZ 12.Cooling systems kBtu/hr E�ciency SHGC: a.Central Unit 18.0 SEER:16.00 - c. U-Factor N/A ft' SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor� N/A ft2 a.Electric Heat Pump 17.5 HSPF:8.50 � SHGC: Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0.000 14 Hot water systems-None required 8. Floor Types (416.0 sqft.) Insulation Area a. Cap:N/A EF'0.000 � a.Slab-On-Grade Edge Insulation R=0.0 416.00 ft� b. Conservation features b.N/A R= ft' None c.N/A R= ftZ 15.Credits Pstat Total Proposed Modified Loads. 11.68 pASS Glass/Floor Area: 0.000 Total Baseline Loads: 12.37 I hereby certify that the plans and specifications covered by Review of the plans and �`C�Sr,��. `.. this calculation are in compliance with the Florida Energy specifications covered by this i.� ,� "' _4 '€Q Code. calculation indicates compliance r,�'��i,,;'' �_:=��. /. with the Florida Energy Code. �"� `L`�=��''���="�;t� PREPARED BY: �G�VE �CD�YIGYG �• trrrrr�:."�•�..:=: •<' O �' •. -'.=�<,;:.:+�.., � Before construction is completed w-�- rc;, .� �'i � r... . __ C7 DATE: this building will be inspected for • �g � k:� 1:. compliance with Section 553.908 � � '� ' � I hereby certify that this building,as designed, is i compliance Florida Statutes. �;i, ., ; �` � ��. with the Florida Energy Code. �'�,D y�rF,`'£�� � OWNER/AGENT: BUILDING OFFICIAL. DATE: - DATE: G - - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as � certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. • 8/14/2017 1�17 PM EnergyGaugeO USA-FlaRes2014 Section R4�5.4 1 Compliant Software Page 1 of 4 ; - � . • , FORM R405-2014 ' I FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION � Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WHC 1941 sf lot 0�28 Hidden river Builder Name: Lennar Homes 0028 I T street: Moulden Hollow Drive Permit o�ice: City of Zephyrhills ; City,State,Zip: ,FL, Permit Number i Owner Lennar Homes Jurisdiction: 611600 , Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing Addition 9. Wall Types(353.0 sqft.) Insulation Area 2. Single family or rriultiple family Single-family a.Concrete Block-Int Insul, Exterior R=4 1 241.00 ftZ b.Frame-Wood,Exterior R=11.0 112.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4 Number of Bedrooms(Bedrms In Addition) 0(0) d.N/A R= ft� 5. Is this a worst case? No �0.Ceiling Types (416.0 sqft.) Insulation Area 2 a.Roof Deck(Unvented) R=1.0 416.00 ft 6. Conditioned floor area above grade(ftZ) 416 b.N/A R= ftZ Conditioned floor area below grade(ftZ) 0 c.N/A R= ft2 11 Ducts R ftZ 7. Windows(0.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 83.2 a. U-Factor N/A ftz SHGC: ' b. U-Factor N/A ft2 12.Cooling systems kBtu/hr E�ciency SHGC: a.Central Unit 18.0 SEER:16.00 c. U-Factor• N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor N/A ftZ a.Electric Heat Pump 17.5 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0.000 14.Hot water systems-None required a. Cap:N/A 8. FloorTypes (416.0 sqft.) Insulation Area EF•0.000 a.Slab-On-Grade Edge Insulation R=0.0 416.00 ftz b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads. 11.68 pASS Glass/Floor Area: 0.000 Total Baseline Loads: 12.37 _� I I hereby certify that the plans and specifications covered by Review of the plans and �'G��T��.,' CS ,-:^� ,�• . this calculation are in compliance with the Florida Energy specifications covered by this 'v - � �+ y<< ��;+ .�{�• Code. calculation indicates compliance ��lr;tis =: ,•,'� *� � � �„�.:a+E� Ati .� , /. with the Florida Energy Code. � � ��r;>>rr�.`�...;=ri�'.�`,;.-'�,ti O PREPARED BY: J7(l/� �GD��'IGi'G �' `"�` :' y.`"�'-�, �' Before construction is completed w� �.t, � DATE: this building will be inspected for � "'"�,�''� ,�. compliance with Section 553.908 * 'Q ,� I hereby certify that this building,as designed, is in compliance Florida Statutes. �z',�,,. � ��� � with the Florida Energy Code. ��!D y�E`�' � OWNERIAGENT. BUILDING OFFICIAL. I DATE: DATE: I � _. � - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. � -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 8/14/2017 1:17 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4 I I� - FORM R405-2014 i FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION , Florida Department of Business and Professional Regulation - Residential Performance Method Project Name. WHC 1941 sf lot 0028 Hidden river Builder Name: Lennar Homes 0�28 , street: Moulden Hollow Drive Permit ot�ice: City of Zephyrhills ', City,State,Zip: ,FL, Permit Number: Owner Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1 New construction or existing Addition 9. Wall Types(353.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 241 00 ft2 b.Frame-Wood,Exterior R=11.0 112.00 ft' 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms(Bedrms In Addition) 0(0) d.N/A R= {�z 5. Is this a worst case? No 10.Ceiling Types (416.0 sqft.) Insulation Area Z a.Roof Deck(Unvented) R=1.0 416.00 ft 6. Conditioned floor area above grade(ft2) 416 b.N/A R= ftZ Conditioned floor area below grade(ftZ) 0 c.N/A R= ft' i 11 Ducts R ftZ 7. Windows(0.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 83.2 a. U-Factor• N/A ft2 SHGC: b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency , SHGC: a.Central Unit 18.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor N/A ft2 " a.Electric Heat Pump 17.5 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0.000 14 Hot water systems-None required 8. Floor Types (416.0 sqft.) Insulation Area a Fa 0.000 i a.Slab-On-Grade Edge Insulation R=0.0 416.00 ft2 b. Conservation features b.N/A R= �Z None c.N/A R= ftZ 15.Credits Pstat Glass/Floor Area: 0.000 Total Proposed Modified Loads. 11.68 PASS Total Baseline Loads: 12.37 I hereby certify that the plans and specifications covered by Review of the plans and ;0�'C�E��"�q�� this calculation are in compliance with the Florida Energy specifications covered by this �,�.-,�,� '*^:�.;; 0,�,, . Code. calculation indicates compliance c�.��i,,;'�, �,:_,=,•r`at�� /./ /" with the Florida Energy Code. � tr:'� u:•�''���.� :;;.�'.'�.���,,,;, d. PREPARED BY' �av� f�Wl�'I�YG Before construction is completed w "�� '' " � `� � ,��:}��...,.... C7. DATE: this building will be inspected for �,ry ,, �+. I�ii compliance with Section 553.908 * �'-`� � � I hereby certify that this building,as designed, is in compliance Florida Statutes. �,�,�, ,."` �` ��� with the Florida Energy Code. ��a 4YE'� OWNER/AGENT. BUILDING OFFICIAL. ; DATE: DATE: � , - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 8/14/2017 1�17 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 ; FORM R405-2014 PROJECT i � Title: WHC 1941 sf lot 0028 Hidde Bedrooms: 0 Address Type: Lot Information � Building Type. User Conditioned Area: 416 Lot# Owner Lennar Homes Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: ' Builder Name: Lennar Homes Rotate Angle: 0 Street: , Permit Office: Cross Ventilation: County� Pasco ' Jurisdiction: Whole House Fan: City,State,Zip: , Family Type: Single-family FL, New/Existing: Addition Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp \� Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 416 3328 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 Main 416 3328 No 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet � 1 Slab-On-Grade Edge Insulatio Main 45 ft 0 416 ftz —__ 0 0 1 ROOF ' / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 465 ftz 0 ft' Medium 0.85 No 0.9 No 1 26.6 ATTIC V _ # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 416 ft� N N , CEILING _ ' ' # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) Main 30 Blown 416 ft' 0.11 Wood j , ' � 8/14/2017 1:17 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS ' Adjacent SPa� Cavity Width Height Sheathing Framing Solar Belo w i 1 E Exterior Frame-Wood Main 11 16 7 112.0 ft2 0 0.600000 0 2 E Exterior Concrete Block-Int Insul Main 4.0999 53 1 53.0 ftZ 0 0:600000 0 3 S Exterior Concrete Block-Int Insul Main 4.0999 3 8 0 24.0 ft2 0 0.600000 0 ' 4 N Exterior Concrete Block-Int Insul Main 4.0999 20 6 8 0 164.0 ft2 0 0.600000 0 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 - 1 Wholehouse Proposed ACH(50) .000254 277.3 15.23 28.63 .1906 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts i 1 Electric Heat Pump None HSPF:8.5 17.5 kBtu/hr 1 sys#1 I COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:16 18 kBtu/hr 540 cfm 0.85 1 sys#1 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 � DUCTS / —Supply— —Retum— Air CFM 25 CFM25 HVAC# \� # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 83.2 ftZ Attic 20.8 ft� Default Leakage Attic (Default) (Default) 1 1 � ; . j 8/14/2017 1:17 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant SoHware Page 3 of 4 FORM R405-2014 ' TEMPERATURES � Programable Thermostat:Y Ceiling Fans: , Cooling Jan [ ]Feb [ ]Mar Apr May X Jun [X]Jul [X]Aug [X]Sep Oct Nov [ ]Dec Heating �Jan [X]Feb [X]Mar E_�APr f �May 4 �Jun [ ]Jul [ ]Au9 [ ]SeP ��Oct �Nov [X]Dec Ventin Jan [ ]Feb [X]Mar [X A r [ Ma [ Jun [ ]Jul [ ]Au [ ]Se Oct Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM SO 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(INEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 ' 8/14/2017 1�17 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 I ENERGY PERFORMANCE LEVEL (EPL) - DISPLAY CARD " . ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPertormance Index, the more efficient the home. , „ FL, 1 New construction or existing Addition 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 241.00 ft2 b.Frame-Wood,Exterior R=11.0 112.00 ft 3. Number of units,if multiple family 1 c.N/A R= ftZ I 4 Number of Bedrooms 0(0) d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area 2 a.Roof Deck(Unvented) R=1.0 416.00 ft 6. Conditioned floor area(ft2) 416 b.N/A R= ft2 7 Windows" Description Area c.N/A R= ftz2 a. U-Factor• N/A ftz 11 Ducts R ft a.Sup:Attic,Ret:Attic,AH:Attic 6 83.2 SHGC: b. U-Factor N/A ft� SHGC: 12.Cooling systems kBtu/hr Efficiency � c. U-Factor• N/A ftZ a.Central Unit 18.0 SEER:16.00 SHGC: d. U-Factor N/A ft� �3.Heating systems kBtu/hr Efficiency SHGC� a.Electric Heat Pump 17.5 HSPF:8.50 Area Weighted Average Overhang Depth: 0.000 ft. ' Area Weighted Average SHGC: 0.000 8. Floor Types Insulation Area 14.Hot water systems-None required Ca N/A a.Slab-On-Grade Edge Insulation R=0.0 416.00 ft� a• P'EF: ' ' b.N/A R= ftZ c.N/A R= ft' b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building �_�ft�E:�T�AT, Construction through the above energy saving features which will be installed (or exceeded) .`,�, -:�� L'O. in this home before final inspection. Otherwise, a new EPL Display Card will be completed ��',��`, �==::r':t, based on installed Code compliant features. � +rrr;��:-`=����°;��w",�'�o Builder Signature: Date: 08/15/17 � ���}��'�'�� - p � g • * ' `.� Address of New Home: Moulden Hollow Drive City/FL Zip.Zephyrhills, FL 33540 '�i�a����j�`�',. � *Note: This is not a Buj ding Energy Rating. If your Index is below 70, your home may qualify for energy efficient , mort a e EEM incentives if ou obtain a Florida Ener Gau e Ratin . Contact the Ener Gau e Hotline at(321) � 9 9 � ) Y 9Y 9 9 9Y 9 i 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For , information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. : '`'`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. S/14/2017 1:19 PM EnergyGauge�USA-FlaRes2014 -Section R405.4.1 Compliant Software - Page 1 of 1 I � • . ' i Buildin Anal SIS , Job: WHCIot0028Hiddenriv... � Y Date: 8/14/2017 � Entire House By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson ' � • ' 0 • For: Lennar Homes � - • • • • Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54 7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7 5 Fireplaces 0 • Component Btuh/ft2 Btuh % of load Walls 5.1 1906 31.0 ��s GlaZing 0 0 0 waus Doors 0 0 0 Cellings 1.3 521 8.5 nfiltration Floors 4.4 1822 29.6 Infiltration 2.6 979 15.9 D ucts 921 15.0 Piping 0 0 ceilin9s Humidification 0 0 - Ventilation 0 0 Floors Adjustments 0 Total 6149 100.0 • • . Component Btuh/ftZ Btuh % of load Walls 2.8 1044 24.3 � Glazing 0 0 0 Walls Doors 0 0 0 Intemal Gains � Ceilings 17 721 16.8 Floors 0 0 0 ' Infiltration 0.6 218 5.1 Ducts 958 22.3 Ventilation 0 0 Internal gains 1360 31.6 Ceilings i Blower 0 0 Adjustments O Infiltration oucts Total 4300 100.0 ' Latent Cooling Load= 1052 Btuh Overall U-value= 0.090 Btuh/ft2-°F ' WARNING:window to floor area ratio= 0.0% - less than 5%. �, .}y- wri htsoft` 2017-Aug-1413:2144 � "t— 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 ...7UHE AH's\WHC 1941 sf lot 0028 Hidden river.rup Calc=MJ8 House Front faces: E , , ' Pro ect Summa Job: WHC lot 0028 Hidden riv... 1 � Date: 8/14/2017 Entire House By: DaveAldrich � Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson ' � 0 ' , e _ For: Lennar Homes Notes: Welcome Home Center � - � o e Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 39 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 55 gr/Ib � Heating Summary Sensible Cooling Equipment Load Sizing Structure 5228 Btuh Structure 3343 Btuh li Ducts 921 Btuh Ducts '1 958 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 6149 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Inflltl'atlon � Equipment sensible load 4300 Btuh Method simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces � 0 Structure 853 Btuh Ducts 199 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ftZ) 416 416 Equipment latent load 1052 Btuh Volume(ft') 3324 3324 Air changes/hour 0.41 0.22 Equipment Total Load (Sen+Lat) 5352 Btuh � Equiv.AVF(cfm) 23 12 Req. total capacity at 0.85 SHR 0.4 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade LENNOX Trade LENNOX Model 14HPX-018-230A21 Cond 14HPX-018-230A21 AHRI ref 10258596 Coil CBA27UHE-018-230'`++TDR ' AHRI ref 10258596 Efficiency 8.5 HSPF Efficiency 13.0 EER, 16 SEER ; Heating input Sensible cooling 15300 Btuh ; Heating output 17500 Btuh @ 47°F Latent cooling 2700 Btuh , Temperature rise 27 °F Total cooling 18000 Btuh , Actual air flow 600 cfm Actual air flow 600 cfm Air flow factor 0.098 cfm/Btuh Air flow factor ` 0.140 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 ' Space thermostat Load sensible heat ratio 0.80 Capacity balance point=4°F � Backup: n/a Na Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Aug-14 13:21 44 �� wrightsoft� Right-Suite�Universal 2017 17.0.23 RSU05714 Pa e 1 9 ...7UHE AH's\WHC 1941 sf lot 0028 Hidden river.rup Calc=MJ8 House Front faces: E a . � ' • Manual � Compli�nce Report �db: WHC lot 0028 Hidden riv.., Date: 811412097 Entire Hous� By: DaveAldrich ' Bayonet Plumbing Heating and Cooling 895�New York ave,Hudsan . . " o � ' � � Far: Lennar Homes • e . • . Design Conditions ` Qufdoor design DB. 93.3°F Sensible gain: 4300 Btuh Entering coiI DB� 75.5°F Outdoor design WB: ?7.3°F Latent gain: 1052 Btuh Entering coil WB. 62.8°F indoar design DB: 75.0°F Tatal gain: 5352 Btuh Indoor RH: 50% Esfimated airfiow� 600 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment fype: SpEit ASHP Manufacturer: Lennax Model: 14HPX-018-230A21+CBA27UHE-018-230'++TDR Actual airfiaw: 604 cfm Sensible capacity� 15300 Btuh 356% of(oad Latent capacity: 2700 Btuh 257% of load Tota(capacity: 98000 Btuh 336°l0 of laad SHR: 85°!0 • • • Design Canditions Outdoor design DB: 30.8°F Neat loss: 6149 Btuh Entering coii DB. 69.7°F Indoor design DB. 7Q.0°F Manufacturer's Perfarmance Data at Actual Design Gonditions Equipment type: Split ASHP Menufacturer� Lennox Model: 14HPX-018-230A21+CBA27UHE-018-230*++TDR � Actual airflow: 60Q cfm , Output capacity: 17500 Btuh 285% of load Capacity balance: 4.3 °F Supplemental heat required: 0 Btuh Ecanomic balance: -99 °F ! Backup equipment type: Elec strip , Manufacturer• n/a Model: Na+n/a Actual airflow: 600 cfm Outpuf capacity: 0 kW 0`Ya of laad 3emp. rise: 0 �F Meets are all requiremants of ACCA Manua]S. � wri htsoft� 20i7-Aug-14 t3:21.44 - g Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 �'�...7UHS AH's1WHC 194!sf lot o�28 Nidden river.rup Catc=MJS Hause Frant faaes: E ' . . ' ---- — ---� i. � � � Ia�� � � � � W.�.C. ' la�$ � . � � -3� ��� ��� ; �itol � � � � ' .� � � � � � $ � 1--�� r : t I?,� ' � I ' I J (`F'� _ ,. -----------� � � . •, � � . �.r� -. K ��, . � � l�iX"# a$ = � i , i i y t��y —=_� � �; -�` ; � � � � - 10 �P� D. I ►1 _ ° I ' 11 •� � GFI '� .`; �� ��/ _ L�..— iy t.S�� C � ►8 . � I �� �te� II . , �� �4 � . _ . . . . _ -- � ---------- . FOYER� � -- � ENTRY � ' +•^ ��_1� i��/� I . ���s r���r�,�� � .I � � GFI ------ S.D. �'�-�,.,_ ,�_...--'r"'� 5.0. ------------ �� - , C.M - 0 � :DROOM 2 � i� � � , 5.�. � -�j BEDROOM 3 � - � \ BEDR44M 4 i,�i 1 : . BAT�►� 1 � ,. ,. � W !��-� �9 yl s� � 4�� s�.�� � :�o � .��- � 1��d.c�en �ii��.�- L.Gnnnx " . , 1 ��,�J': o:l�- . �f . ..X �:�:� a�',7'�'tT���'I? �//�"� /�'�"T"d� I ` �i ' .���lJ,�`g��r:�y�� � ,. - � � : PASCO COUNTY, FLORIDA '. . , Permit No. � � ' Date Permifted -2. _ -� � Builder NamelOwner Name �'.r2-w�.Lt-r ITdmes �.� Contrai# Ii � Gounry Parcel No. '2�~2-�2-�-fl(�rzp—l�D�,�?t�—62gb SubDiv: 2��dest.l�l�r�� � AddresslLocation �.2-�3 �I1G{.t�e.t ��f dt.c.� �t�_ Classificatlonfi'ype of Use �,���,�,�7 T�& i��� TRANSPORTATiON IMPACT FEE • Rete: Sq Ft Unit: Zi3 7(o � Exempt �Yes (� No How Determined � impact Fee Amount $.31 (�32 Zone No. TAZ: , SCHOOL tMPAC7 FEE Account (056) Single-Family Datached House Amount .$ �,�7�,. 2� {057} Mobile Home � , (Q58) Other Residentiai � '!23) Collection Fee �. . Exempt [t]Yes ❑ No How Determ(ned PARK3 AND R�GR�lr►TION FEE � Land Account Land Credit Land Totat � t Recreation Account Recreation Credit •Reereation Tota! � , Zone TOTAl.AMOUNT $ 1�G� cS� � Exempt �Yes [] No How Determined LIBRARY FEE �and Accaunt Land Credit Land Total Fac�lity Accaunt Faci(lty Credit Facility Total � Exempt ❑Yes ❑ No How Determined Tatal Amount �.�---� RESOURCE FEE ERU ' TO'fAL AMOUN7 , � Prepared By -' , Checked By � � ' NO CERTiFICATE C?F OCCUPANCY WILL BE ISSUED OR FlNAL INSFEGTION � � PERFORMED tlNTIL THE TC?TAL AMOUNTS LISTED HAVE ' BEEN PAID AND � I3ECEIPTED FCfR BY A CENTF2At PERMITTINCi OFFtCE OF PASCO COI.INTY Acknowledgemant below does not impiy accaptanca of coneurrence,but simply recalpt of a copy af this form,piacing '� � the buflding pecmit owner an no8ce of this sssessment and ihQ conditlons of payment for same. �. C�ATE REGEIVED BY � RECEIPT NO. DATE BY , �_Y__r,.�---=--�--- -_-_ ��-� � • � Moulden Hollow Dr Lot 0280 o umn SQ. FEET PRICE UNDER ROOF: 2,376 $ 112.65 I OTHER: - $ - VALUATION $ 267,656.40 FEE SHEET $ 992.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 � BUILDING: $ 1,091.84 ELECTRICAL: $ 223.20 PLUMBING: $ 148.80 MECHANICAL: $ 104.16 SUB-TOTAL $ 1,568.00 TOTAL $ 7,568.00 SEWER: $ 2,010.00 WATER: $ 641.00 IRRIGATION: $ - TOTAL: $ 2,651.00 WATER METER: $ 473.78 IRRIGATION METER FIRE DEPARTMENT FEES � PLANS TOTAL: INSPECTION TOTAL: ; PERMIT TOTAL , TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 � TOTAL: $ 553.35 SUB-TOTAL $ 5,246.13 � � PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 , T I F'S: $ 3,632.00 � 99% $ 3,595.68 ' 1% $ 36.32 , TOTAL: $ 14,523.97 , Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. 9. No electric,plumbing, mechanical, or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 I 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. �I 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. �I 17. All means of egress are to be in accordance with R311 of the F.B.C. I 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. �I 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all I underground plumbing and electric. � 22. A112008 N.E.C. Codes will be enforced. 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 22. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code Sth Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008) I _. a i� �' .� ; - r T �• . � r ��°�a� ��,{ ��� ' �� .� �� �� � � � � �q i b,�$. �'''"y� "r° f!� �'+y� I '� �� � Y�d� �. b� ' � .. �.,. �. f r° �'`'., •`� Ot�'4:t ' � ` . •' L tr �` ti ; �.,` `.�, ,° ! � `` ! -�� M _ .. � � �, � � • � � �°',,, `'.� � .�'"� �"°o, � �• � �, `��� � ':,� �°�. e� � � �•� ,,,.�: . •� '� � �.� r �� �B�� � � f� �4�� ``�.� `' �. ��°� �. `�� �ta' �od� ► ,� ,� ,� ,� ;x,,,�"'��' � � � -�� . � ..�, t� �-�..� ��r� . , �,� � �� � � � �'�,�• 4� �' �,� � _�``�- _..,.... t l.,��..�.� ��; �� _ '� � � -�� . ti . � �4 �.� � �..,,_ `'--q.r � �,' �°-� , .;'� . '�$��, �� � `� �� � .�.-' ��7 j � �`"'°�:.. ,'�� �.� � Q �� . '� � �',� �'"� t � ��� � 1 ��� �t '�'� ' _ � ,r� � �•�� ,r,�° j. � t Z �� '� `. � �£ t �t ,���,,� `°'�..� . ., ��� a i : '� � , � ° � . ' f. _ _ �._,+. p �.... �.5.. _ ��� � �� �,,,,r � ���� �,,�� � ��-�-�^�^-��-""—�—�.�,.���.�....� ..,v s �' —�,�y"'�� � �y . ' �--,—..,,,.....�...�+�..� � . ..., .. ,.. ..... ..�. ......... ....._ ..,.... _._.. .. , E i Y �. • `'� ���� ' �� � a � �+�� . � � '�� ��1. �' rr � s�; , _ « ' � � '�� �� �� j i° r�: ....�� a... ,....i j L_ �. .__,��.� � ' , ,, r..._--.•���r -,�''1 9�».......,..�_, ...��� ", -- �,_�.• �.J ,. .�5 ,. ��� � ! ' � , ��' " '""" �Tyti""� ,,� � '' t � �� � � ��� �a� � . � � � I '�� ; - - � �� E ��:� ' . _�..��� ,� �.,� _ __ .� .� �'� � ,�:; �` . --�.�-��.---��.���-,,.,..,... .�.Y.;� �� �_�_ `s ` f., ,� .,. �� ,.� ..,__. ..,,` , .... ... .............. ....... ..... w '� �` . , _.�.�.�. _.....",�,.-� � :.. .�: •""�.�" � � ,t.• ., ��--' �� �'' ,,� �, ` . � . . �;�. �" �� � i ��� -s� �, � -� : �„ . . �,., , '� � , . �.�, #���� � F � . : , � —��: .,..� �.. _....,_.�. . �a� � t � , s .._W__ ,_�,,:� '� _.._,�...��_.�^�w : ' �`_—°-= _— �� ' - �. ,� � a � ; ,��, .�. ,....,..... _�.,.,� � .; . :f �'� '��� �• T :� - --���� ��,c - ; - �r . '� � f � � - � ��a . B � � -�� ,; �` �� �� , , I . . - ` p — ———..I t�.......,.,�.:..�.�..,r..�.._ �� ; . ', � ? � • . ..,. . -——-�-��—-A� .,....�.,�.,�.� �,�.,...,..� ; : ` .�..�,..a " . ' . � r . � ; .Y.�.� ; ; ��: � . � �., � �� _.�.,r...�_���.�,..� ,� � :.�. � ��� � � �_ �,. �. ;� o .� �� ��]]►� �'� � �� "`'~��� �' ;..� `� '� � ��'�� ,�� . , � �: ? _���, � � s. S �` . �+� ���..,_ �_._ � , .� � � : , –— —�.� .�..._._�...,,.,�_�.M.�,_.� �s . =—=,'�..,.=_ J x:� � �. � � � ., . � �:` : ..a...,.',__._.� ..�,,p,. s � � , i �tF ��i� : � r , �� ��� �� . << . � . �,� , � , - � �"�' I 1 ! �'{ ' �� �',., �* i.0� M .�V�! � � � ' �_.. .,,...r.,�� L_y __ . �� �. �"� � . �� h , i —��.�..�.. . . - � .�.�....... ; _...,,., �` t j --�.�'—..._,_.�+�:�_� 3 ( p.�� .Y...r.......� � ,� �� 'y ��1'�` ti `r �'�`-�'r��+���-- �r^^•-� -� i tl • � � � �E'EL ' e 1R ' � ' . � ;�,�� . � � '�� : �• � ;� .. , . � � �� �ra. ����•�'�. , e ! ' . ; . T__ .......,�. ! L.�. __e.._�__ '��3 , ... # r� ,�. �,r.�,..,.._,���� � ,....�.�^ ^� : ; ���__�_� _� ; .___....,..�....................:...4�'.'...,..,..,.,..,,.,,,..,,._,,.�,..._,,,..,. a�r�. ��� - j � �� �� ��et � .�`� i �j ,� . .._ : I # � _ � �� , ' " �- • , �`► e��ar. ��L €� �:� . ������ L_._._..i�_�.�,-- } _��� � __..i ;; ; . `' . r �• ��� �'; y, "i� ——.--,.�.__��.-� .� _ , � '�"3�� � j � , �� � . � ��. � I �� `'� . � •. I I , I '[�� ; �°�t '' � :x s � .�.a t.� __ � � -r��.a �� � . .� .^_ _ --— — � –.-. , ,� � � m� 7 F�sa bss w��u�. w.�ww �ry. w �r r�.w.� �i aw�..�i - ,S I � f_ �,......,� g8 � � � � .�..�,.,.........;.#�.��y�;,.,.� ;+ • ' ' � ��� � . � � ' °�� ��'�� � �r �' .�: � .� � ' , . . - � � � � ��-�R �t� � ;7 � �.�..�.� �.__',....�.�...��.__ -�� � :�,: , � � � ..��, . � ,; <; �—�— .-�. �.-- . -- ��� � -- � ---�—� ;3 ' �. a�►� � � ;i ; t1�"4�t ' _ �— ^�. i ,.��,� ., • . r�� ��x�; � I, 1 � E 't��s � '�` :� � � ' . �� l Y �� f `�. - , ' .� l .. . , o�t "w,`,,, � :� + E i � .�' .+�� �.,,�.,.,,- � ��- ,�' .!1 ;.� � - . . � . �. ��`"",,,, * � �J' '.{ � � • ,,..> ,.�,.,�„..�..� . .._ .... ., i ........_._...__.. " . .,.,�`��,' �� '�..T��."+ti. ,��9 .�'9 ';.� . 1 � SKETCH ONLY SEC. 24 , TWP. 26 S, RNG. 21 E. PLOT PLAN NOT A BOUNDARY SURVEY LOT 28 BEARING BASIS: HIDDEN RIVER PHASE ONE A NORTH BOUNDARY OF SUBJECT PIAT BEING S 89'40'43" E PASCO COUNTY, FLORIDA. �T THIS SURVEY IS SUBJECT TO ANY FACTS THAT j� MAY BE DISCLOSED BY A FULL AND ACCURATE PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS TITLE SEARCH. ALSO SUBJECT TO SETBACKS, THIS PLAN IS FOR PERMITTING PURPOSES LOT =_ 6599_34_SQ. FT. _ EASEMENTS AND RESTRICTIONS OF RECORD. ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA = 1556 _SQ. FT. o ALL DIMENSIONS BEFORE ANY CONSTRUC110N. ENTRY = _45_�SQ. FT. "� UNDERGROUND FOOTER, STEM WALL, AND ' GARAGE =_407__SQ. FT. II UNDERGROUND UTILITIES ARE NOT LOCATED OR LEGEND: COVERED LANAI =__1A_SQ. FT. SHOWN. �—�= PROPOSED DRAINAGE FLOW PATIO =__23___SQ. FT. ^ DO NOT SCALE THIS PRINT DIMENSIONS AND CONC. DRIVE =__4_75�_SQ. FT. � NOTES TAKE PREFERENCE. (00.00) = PROPOSED GRADE A/C & CONC PAD =__18 _�SQ. FT. � E-00.00 = EXISTING GRADE PRIVATE SIDEWALK = 29 SQ. FT. N DESCRIPTION NOT CONTAINING PLAT BOOK AND IMPERVIOl1S =_39__y, PAGE INDICATES THAT PLAT IS IN NOTES: — _25_53 _SQ. FT. PRELIMINARY STAGE AND IS SUBJECT TO LOT GRADING TYPE = A SOD =__4046 _SQ. FT. CHANGE AND/OR REVISION. PROPOSED PAD ELEVATION = FRONT SETBACK = 20' OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON i SIDE SETBACK = 10' RIGHT OF WAY = 720 00 SQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT I REAR SETBACK = 10' DRIVE APRON =_ 14_4�_SQ. FT. STRUCTURE TIES SHOWN HEREON DENOTES PUBLIC SIDEWALK = 2_40_SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION SOD =__33_6___SQ. FT. TO PROPERTY LINE. TOTALS * = 10' DRAINAGE/UTILITY EASEMENT AREA =_7319.34 SQ. FT. DRIVEWAY =__F19 __SQ. FT. SIDEWALK . =__269 _SQ. FT S 89'36'S8" E SOD =__4_382 SQ. FT. 25,00' - I � a . a U a '�, .,� I 0 I � � I LOT 335 (LJ I • _� PLAT � BOUN AQ RY I Q �i ��R r�� . �y .O'� _�--► S 89°36'58" E 109.99' �� �s'� ,% � � I � �o o � 0 0 •~ J 2s.s�•I J� I � 24.49' ' ;:': . . O.,. O\ UNPLATfED IAND(P) � .J'o'�•: - . �I� • .��•- �' c,a�_`� +� �.. :� � ..�_ � I _ - � • ..;�.. q ,' W w w ao = ,.1,:.•. . �:'_.'. ,' �z O (nZ�Q�I- N • y.. ... �:' � o pa°i�¢� 0 29.00'I * N w � `t �' J U' J I O � N °' w 20.50' I� � N I O � F� O '4�C a� 65'-0"� p O z 24.49'�� 20.50� � � I o o i . 0 o I ��o�� `�� N 89°36'58" W 109.99' �� �,yo1 :�'• 2s�o�' TRACT "I" L L BUFFER/DRAINAGE & I IANDSCAPE EASEMENT I • n :';,. LOT 29 , , PROPOSED: LOWEST FLOOR ELEVATIONS: � LIVING AREA: 74.80' ' GARAGE AREA: DESCRIPTION: ELEVATIONS REFERENCED TO LOT 28, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE A", NATIONAL GEODETIC VERTICAL AS RECORDED IN PLAT BOOK 074, PAGES 101 THROUGH 121, DATUM OF 1929. MEAN SEA OF THE PUBLIC RECORDS OF PASCO COUNIY, FLORIDA. LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL N0. 120230 0460 D EFFECTIVE DATE: 9/30/1992 - LEGEND• (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, �= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM�T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, P6= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL"&-DISK„ TBM= TEMPORARY BENCHMARK, U P= UTILITY POLE, W F= WOOD FENCE, R = RADIAL � ' - JOHN R.BEACH&ASSOCIATES,INC. Drawn By: SMS Square Feet: ��6599.34 �t_ ^- __ LENNAR HOMES � SURVEYORS AND MAPPERS Checked By: . _ ' �, �_ 911 WEST ST PETERSBURG DRIVE JRB - ONE OLDSMAR, FLORIDA 34677 - —' -_ WAY (g�3) 854-1276 FAX (813) 555-8370 Scale: �^=30' ' - - �,` NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 7 31 17 ACS '' - -� !"LO/ THE ORIGINAL RAI$ED SEAL OF A FLORIDA JOH . BEACH -- y� DATE LICENSED SURVEYOR AND MAPPER FLORIDA G. L'AND SURVEYOR.No. 298'�} LB 4493 Revisions: RERVISED PER LEGAL 8/18/17 JBS - � ; -- _ _ .