Loading...
HomeMy WebLinkAbout17-18889� CITY OF ZEPHYRHILLS 5335-8TH STREET ,: � �sis��so-oo20 1888. . • BUILDING PERI�IT SINGLE FAMILY RESIDENTIAL �� PEi2iVIIT INFORMATION `- � � - LOCATION INFORII�IIATION � -- � - Permit#:18889 Issued: 9/29/2017 Address: 36006 STABLE WILK AVE Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 267,205.80 Total Fees: 11,399.19 Subdivision: SILVERADO Amount Paid: 11,399.19 Date Paid: 9/29/2017 Parcel Number: 04-26-21-0070=00200-0150 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W. CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA, FL. 33607-4099 Phone: (813)574-5743 Lic: Phone: (813)574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2,372 SQ FT APPLICATION FEES PLUMBING FEE 148.80 ELECTRICAL FEE 223.20 MECHANICAL FEE 104.16 SCHOOL IMPACT FEE-sfd 1% 48.28 SCHOOL IMPACT FEE-sfd100°/u 4,828.00 TRAFFIC IMPACT FEE 1°/u 36.32 TRAFFIC IMPACT FEE 99% 3,595.68 BUILDING FEE 1,091.84 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 t ��� . �� � ���,�� ,d� r � � . I � � Ins ections Re uired F OTER 2ND RO GH PLUMB MIS INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECRON FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. iV0 OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. � CONTRACTORS SIGN TURE PERMIT OFFI � PERMIT EX IRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CAL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Q� . �.�I:OHIIIP r ���� ��`�'�, yia �r`.�. . • �ar . I� _ i ' b City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: ��{�CF,� � - Date Received: � —�— � 7 — 7``L � Site: � 6� l0 �/ � �i � � r � � �� Permit Type: a 1, � S � �.. 'i _ �,pproved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ ' � � This comment sheet shall be kept with the permit and/or plans. �� ���� --�. Kalvin Switzer- aris Examiner Date Contrac r and/or Homeowner (Re ired when comments are present) i i Lennar Homes-36006 Stable Wilk Ave-2,372 sq ft I� o umn SQ. FEET PRICE MAIN OR LIVING: 2,372 $ 112.65 OTHER AREA UNDER ROOF. - $ 88.00 OTHER: - $ - VALUATION $ 267,205.80 I� FEE SHEET $ 992.00 ADDRESS $ 40.00 DRIVEWAY $ 40 00 BUILDING: $ 1,091.84 ELECTRICAL: $ 223.20 PLUMBING: $ 148.80 MECHANICAL: $ 10416 SUB-TOTAL $ 1,568.00 TOTAL $ 1,568.00 SEW ER: n/a WATE R: n/a IRRIGATION: $ - • TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 S U B-TOTAL $ 2,121.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 ' 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 � 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,399.19 04-26-21-0070-00200-0150 � Pasco County Property Appraiser Page 1 of 1 ' � Data Current as Of: Weekly Archive -Tuesday, September 26, 2017 Parcel ID 04-26-21-0070-00200-0150 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $25,562 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 36006 STABLE WILK AVE ZEPHYRHILLS, FL 33541 Just Value $25,562 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $25,562 SILVERADO RANCH SUBDIVISION PHASES 2, 3 &4 PB 73 PG 059 Taxable Value $25,562 BLOCK 2 LOT 15 7urisdiction City of Zephyrhills ' ------ -- - ---- ---- Land Detail (Card: 001 of 001) Line - . ---- ---------r-;--__ � --____--,-- ---- ____ _�Use� _ ;Descr�ption{Zon�ng___�Units ___�Type _ ___ IPrice :Condition�Value _ 1 (_ 0100� � _ SFR__; MPUD__� 6,000�00 � _ SF _�_$4.25 _j__ 1.00V � $25,500 2 � 0100 j SFR ;�MPUD ; 187.00 � SF ; $0.33 ; 1.00 I $62 � Additional Land Information ------- ----- --- --_ ____�__---- _-----_-.___�---_____-T--_-_____-,- ---------------- ------------- ------ Acres � 0.14 �Tax Areai 30SI i �ode f -- ! Residential Code � SLVRLPI Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) __..�__ _ _ - - -- -- ---- - - -- - -- - - I Line-----w_, - T�--JDescription_. .___.__Lear _..__�__._�_ ._ _i_Units --^-_--_ -�Value --�- --,---�- No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year ,Book/Page �Type------y- __---�--____.--___----------------:---__.---- -- - ------ -- -- - - - ----------- _ - -- ------ � DOR Code �Condition iAmount _ r--.�. ..__._- ----t----"-------f-----'----------.. ' 09/2017 9606 /�2241 Warrant Deed 05 Vacant � Multi-Parcel Sale ---- -- --- ___.__�____._____._.�_____.___..__��._.__.._.__�___�____�__..y._-----___�___.—_ - ------________;_,___�__._._______. 09/2011 � 8606 / 3376 _ _ ! __Warrant Deed ; 05 __�_ Vacant _� Multi-Parcel Sale � 05/2010 I 8373 / 1912 ; Certificate of Title j 12 � Vacant ; $0 http://search.pascopa.com/parcel.aspx?sec=04&twn=26&rng=21&sbb=0070&b1k=00200... 9/29/2017 � �iiiiii�iiiiiiiiiiiiilii►il�i�iiiii�i�li���i�i�i��i<��i����i 2017152707 , -----�__ � ' r2cpt:1897567 Rec: 10.00 �---- I , : . , DS: 0.0@ IT: @.@0 _ @9128J2017 C. F. Dpty Clerk , 'AULq S 0'N�IL,Pn D PASCO CLERK & COMp7ROLLER . @9/28/2027 .Q3.39 m 1 af 1 � OR BK ,��1� pG 1'�'�� . Perrnit No. Parcei iD No 04-26-21-0070-00200-0150 , �� NOTICE OF Ct}MMENCEMENT State of Fiorida coun�y of Pasco THE UNDERSfGNED hereby gives notica that improvement wi(I be made ta certain real property,and in accordance with Chapter 713,Florida Statutes, fhe following infoYmation is provided in this Notice of Commencement: � ' 1 Descr'sption of Property: Legai SiLVERADO RANCH SUBDIVISION PHASES 2 3 &4 PB 73 PG 59 BLOCK 02 LOT 15 sc��ecadd�eSS: 36006 S#able Wilk Avenue Zephryhills FL 33541 2. Generai Description af(mprovement Single Family Residence!Poo!/Screen Enclosure/Fence 3. Ownerinformatiorr. ��nnarHomes,,LLG - � Name , 460�W Cypress St 5te 200 Tampa FL 33607 Address Cify State , � � lnterest in Property� � „ _ . Name of Fee•Simple Titieho(der: N�A � - � {!f other than owner) , � � � Address , Ciry State a confractor Lennar HorrSes, LLC . � Name , � 4600 W Cypress St, Ste 200 Tampa FL, 33607 � Addra"ss City Stafe , Contractor's Telephone No.. �'13.574.5700 ' 5. Surety N/A . . � � Naine Address City State � Amount of Bond: $ Telephone No�_ ` 6. Lender: N�A Name Address ` City Stafe Lender's Telephone No.. 7. Persbns within fhe State of Florida designated,by the awner upon whom notices or other documents may be served as provided by Section 713.13(1)(a}(7),Flarida Statutes: � Lennar Nomes LLC : Name 4600 W Cvpress St, Ste 200 Tampa FL, 33607 Address City Slate . • Telephone Number of Designated Person: $13.57�4.57d0 _ 8. In addition to himseli,the owner designates N�A of to receive a capy of the Lienor's Notice as provided En Section 793.13(1){b),Florida Sfatutes. � Telephone Number of Person or Entity Designated by Owner: � 9. Expiration date of Notice of Commencement is one year from ihe date of recarding unless a different date is specified: , ,WARNING TO QWNER: ANY.PAYfUiENTS MADE 6Y THE OWNER AFTER THE EXPIRATION QF THE NOTIGE•OF GOMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTlON 713.13, FLORlDA STATUTES, AND GAN RESULT IN YOUR PAYING TWICE FdR tMPROVEMENTS 70 YOUR PROPERTY. A NOTICE OF GOMMENCEMENT MUST BE RECQRDED AND POSTED ON THE JOB SITE BEFORE THE F1RST lNSPECTlQN. Ifi YOU INTEND TO OBTAIN FINANC(NG,CONSU6T � , WITH YOUR LENDER QR AN ATTORNEY BEFORE COMMENGlNG WORK OR RECORDING YOtJR NOTICE OF COMMENCEMENT. STATE OF FLORIDA = .,--''C_._•-� CQUNTY'QF PINELLRS — t-'' � Signature of Owner or Owner's Authorized Officer/DirectodPartner/Manager . � , Vice President Signatory's TitlelOffice The foregoing instrument was acknowledged before me this 27 day of MafCh c��11 ,by � � Steve Robert Smith as Vice President , . (type of authori .,o cer,trustee,attorney in facf)for Lennar Nomes LLC (n p�tty on 6 om instrumen#was execuked). ., . Personal(y Knawn�OR Produced ldentifcatian❑ Notary Signaf re � Type of Identification Produced Name(Print) Elissa Hol[eran � Verificafion pu"rsuanf to Section 92.525,Ftorida Statutes. Under.penalties of perjury,i dedare tfiat I have read the foregoing and that the facts stated in it are true to ths.best of my knowledge and belief. ____� . � ��"� �-''t--,:1 ' � , ,.`"�?'�;r ELIS$AA9,HOLLERAN , Signature of Natural Person Signing Above � :�; ;,�Comml�slon#FF965837 � � a°Ex�fra�s Juna 6,2020 wpdafalbcsJbcs form: ��4����''� Dondu!'fhNTroyFalnln�unncel04ai5-70{p � ������ � ° �` ° ��'�. � � ��� �\ 1��� � :,���� � �� i��: �`�� ���^�� s� K@� �v d'�p _ � r o ��. ��� A'� '�, . O. � �. . ������ ..� � � ��A�'E 0� F�Q-.��4�3A, CC��f6�T�'OF P,4SC0 7NIS IS TO CERTIFY I HAT THE FQRcG01NG IS A TRUE AND CO@RECT COPY OF THE�OCUMElvT pN FIL.E OR QF f'l►QLIC RECO G IN 7HIS OFFICE WITN SS Y AND AND OF CIAL SEAL THIS � �HY or- 2�/ry PHULT� O't�EiL, CLtRK COi.PTROL�L--l.�-2" - �Y DEPJ?Y CLE;K I J s�s-7ao-oo2o Ci#y of Zephyrhills Permit App[ication FaX-s�s-7aa-oo2� . Building Department Date Recr�ived $13 363 _ 2891 Phone Contact far Permitting M 1 ! 1 1 1 1 1 1 I ! t 1 Owner's Name Lennar Hoznes,LLC Owner Phane Number 813.574.5700 4wne�'s Address 4640 W.Cypress St.Ste.2Q0,Tampa,FL 33b07 pwner Phone Number � � Fee SEmpie Tltteholder Name N�`4 � Owner Phone Num6er � � Fee Simpie Tittehoider Address N/A - J06 ADDRESS 36006 Stable Wilk Avenue �QT# 0150 SUBDIVISION Silveredo Ranch Subdfvision Ph 2,s,&4� pqRCEI.ID# 04-26-21-0070-00200-0150 (OBTAtNED FRONi PROPERIY TAX NOTIGE} WORK PROPOSED II✓ I� NEW CONSTR� ADD/ALT �� SIGN Q � DEMOLISH � lNSTAL.L REPAIR PF20POSED USE � SFR Q COMM � OTHER TYPE OF CONS7RUGTIQN � BLOCK 0 FRAME C� STEEI. Q DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF �376 � r�Q FOOTAGE 1936 HEIGH7 1 Story� �$UILDING $���,.0�� VALUATION OF TOTAL CONSTRUCTION ���j �ELECTRICAL ($— � � PROGRESS ENERGY Q W.R.E.C. � � � AMP SERVICE � , ,,,... �PLUMBING � � � � �� ��MEGHANECAC $ VA[.UATION(?F NtECHANICAL(NSTALLATIORI � � `L_t �GAS � ROOF3NG Q SPEGIA�`T1' � 4THER FINISHED FLOOR ELEVATIONS � � FLOOD ZONE AREA I�YES �10 �_t t_.,t � • •_f • • • • • � • • � � • • • • • • � • • • • • • • • • ■. • • • • • • � W...Y � • � • • • BUELDER �Q�PA�Y Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N 4600 W.Cypress SY.Ste.200,Ta pa,FL 33607 CGC1518166 � Address License# E[.EGTRiCIAN GQMPANY Edmonson Electric, �t1C. SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Address 1�34 Skipper Road,Tampa, �.33613 �icense# �C93005408 � PLUIVIBER CC}NIPANY ��y�net Plumbing, Heafiing &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Ac7dress �'.�. $ax 5308, Bayonet, FL 346T4-5308 ticense# �FC042998 � MECHANICAL �p�Jpp�y Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Address P.O. Box 5308, Bayanet, FL 3 67 -5308 �icense# GAC058062 —� OTHER COMFANY S(GNATCIRE REGISTERED Y/ N FEE CURRE� Y I N Address 4211 Shoa!l.irte Blvd, Spring Hil, FL 346Q7 �ice�se# CCC057991 �� � � i � � t � � � � � � � t � � � � � � � � � i � i � � � � � � � � � � t � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum fen{10}working days after submittal date. Required onsite,Consfruction P(ans,Stormwater Plans w!Silt Fence insta!led, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects C4MMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-Q-W Permit for new construction. -- Nlinimum ten{'S p}warking days after submittal date. Required onsite,Construction 3'ians,Stormwater Plans wt Silt Fence insta{{ed, Sanitary Facilities&1 dumpster.Site Wark Permit for all new projects.All commercial requirements must meet campliance SIGN PERNIIT Attach{2)sets of Engineered Plans. "*"*PROPERTY SURVE`f required for a!1 NE1N construcflon. � _._.__. . ._. . . . . . . .. . . . . �. . . . . ._. . . . . . . . o . . . . . . . . . . . . . . . . . . . . . . . . s . . . . Directions: Fil]out application comp(e#ely. Owner&Conkractor sign back of application,natarized If over$2500,a Notice of Commencement is requlred. {A/C upgrades over$7500j "� Agent{for fhe confractor}ar Power of Aftorney(for the owner}wouid be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs'sf shingles Sewers Service tJpgrades AtG Fences(PlotlSurveylFootage) , Driveways-Not over Counter if on pub((c roadways..needs ROW � � -- NOTICE OF DEED 4�ESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance wifh any � applicable deed restrictions. . , UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATIOfV IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact , fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWf�ER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/UVastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for Iots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOU13 FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICEAOF COMMENCEMENT. FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACTOR Subscrified and sworn to(or affirmed)before e this Subscribed and sworn to(o aff ed)before me this GI-JUI-I/ by paul Sweeney z�-���-» by Paul Swee e � - Who is/are personaliy known to me or Who is/are ersonall known t me or as identification. as identification. Notary Public � tary Public Commission No. FF98537 ommission No. FF98537 Elissa M.Holleran Elissa M.Holleran Name of Notarv tvped,printed or stamped Name of Notary typed,printed or stamped - �I���I��al�S�IV� — , �i��.����r��n��+w� �- ��i:���wA�����u�aa� e��mm'�a�an�.�1�0l�A�,�.. � � �&�k��l,�c���,�Gi� ��4��1�dVlt�1��'�29�0 �� � 6�a�M7��a't,»�IR'ela4�o�n€tlt�Wls,,�+ll � �I � 9uJ�1�'IhN'[.�F,�eSW4t��1�DiW�9�II - - - - / �`4 ' ,' PASCO COUNTY, �FLORIDA . ..� : � Permit No. � ! Date Perrnitted _ g_Z9 l7 Builder Name/Owner Name ��,v��,. ��� � , Control# County Parcel No, Q�_��(�Z���� � � � � 6�� SubDiv: � Address/Location ��Od�p ��� �I � , I, - Classiflcat(onlfype of Use ��yt c � ; TRANSPORTATION IMPACT FEE . Rate: Sq.Ft Unit: Z.� 7 7 Exempt [� Yes � No How Determined ' � Impact Fee Amount $3,� �� • Zone No. — T�: SCHOOL IMPACT FEE �— � Account (056) Single-Family Detached House , (057) Mobile Home Amount $ �,�?�� �o (058) Other Resfdential �123) Collection Fee Exempt Yes � No How Determined PARKS AND RECREATION FEE � Land Account Land Credit Land Total � � Recreation Account , —_� Recreation Credit __�Recreation Total Zone � -- TOTAL AMOUNT $ ��9, �'� Exempt � Yes � No How Determined � LIBRARY FEE - Land Account Land Credit Land Total Facility Account �_ Facility Credit ' Facility Total � Exempt �] Yes [] No How Determined � I � __ Total Amou RESOURCE FEE TOTALAMOUNT ERU � Prepared By Checked By , NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE ; RECEIPTED FOR BY A CENTRAL P RMITi'NG OFFICE OF PqSCO COUNTY Acknowledgement below does not Impiy acceptance of concurcence,but simply recelpt of a copy of this form,placing the bullding permit owner on noQce of this assessment and ths conditlons of payment for same. RATE RECEIVED BY RECEIPT NO. — pATE � �_ BY i Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. 9. No electric, plumbing, mechanical, or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. A112008 N.E.C. Codes will be enforced. 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 22. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 5�'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2008) ,G)�, •L�' .�\� \ '�a , ^,OJO .�q^"' a'r � _ �vJ`�' ,1��.' �T a�O� � 9' ' �.- �\ � -i�' �� SY.�40.Q2 ' � � � � NP= . � h��C r���i. C� �Q �� �O• �Oj pr T� Q `C ��� , ,(1" �T' v � y- r _`� , \ ,��,- o� �ti o� `.�o � •1�0 �� . �� � =,�� o � 6 �� �,.c � : �� _ -' � � �� :'� '� :� • o,� a� � r °�� .a;o.`� ''� T`'-�`. � 1 , � °, C� �'1 , • - . :°�C , � c�,. .� , • cj� � '` ;ob:� p�.• _y'1 b ,��c' ,c ;°��°'' ��'`�' T �,' `` q,��• , '\ • ��• g .,1 • • ' ' o �� - --' . �5� �" _ �r ,r��;�t ' J;Z-' --- g� O � ' -�' � �� � J' � � -- � (iA`• 'X ` '^ • i � v ' � .`c`�,' � . G,� �-� �j'y. �` � '\ • ' \Q"\ �� 5 ,J � 'o- . `L ��6 a�. '1 �f .i -L°� • '� kg� ��, ;�`�� C'� ` .�Ck� .:��� ;�`�' ��` ��°� � a�g �$• �%� �� '.o,�.. . _ .` n:- a��•• • � �� �g.•'' � ��� .1` ~. O� a ' .C�1 � � 1 '.," . _ 'la ^,� ��J ��� ��j��\ '`_"�` '�. � . , .a.o�.p•o-o•o•a•. ---�- `a�_._.. •�.5, ".0 ^ k ', -Q _� -'`� � o� o `.�� ,�:^-_. ^�7 ���j • • .� c.G.o o'�°a '• / ' ' _� � � Q,,' ,�' J \ �v�s.a� '°� •��" ^� o� „ �•�.c'° .�•_ ' . �; `l, � '�a�-e-a�a-; ; �� "1 �� �' .�,°� �� _� � ` �c� g o� � � , `'v q� , �` � ���. o o�� o.°� c, o �o� o,� �, � a �. _ 6 ` . � ,�O �� -t, 7 ,Q.��'°�OD ~� � � • ', 1� o. � �"'�. � ' ,�937 , �- �� e` \ � o•a�'ko . ,� ; � � � . o,� ,� O' �D�. ����,✓ ' � '• �, '�,0.0 � +�' ,. k� `C . •. '� „ �� 'r` � _ ." � � �r� � p ��o �so ' �� � � \v�` ,�o'�� ��� ;� '� ✓ _ �', .`�� :� , FO tfl2 1 L0�3 l' LO p�C �9.90 •. �o' ,�� 1, k � ` 040' ' r �•� LOT 32 �t A0=100.4 f ' PA'�99.9 QT 29 FF=99.70 p . ' ' �'`0.. �� ` p� , PAD'=99.2 30A � . a\ s ' f==10�8 �,QAQ=101.� , -- Y LOT 3 I TYPE B � �YF,E 8 TYPE'$, P �T49.0 FF=99.70. _ r Grx O +a � , •. �' T.7PE A/8 � ' .�� � Fr=10d.0 P�8=10Z 1 , I I I ��� �E B y TYPE 99 ^ �o /1� � 7\ •� LOT 34 I � . t •�`�'pc p , - � �� FF=;�S. AD-103.3 '. I I _� ��J' =99. . '' k � 7' ` � �'• LOT 35 TYPE A� � •-' * _- - ---- '� _ J �p��2,�' .;_ • . � . �. �� ^J FF=1�6.b AD=10d.8 . �� � -�.� ��� i -- ---].T____ ' �� PAB`=98.9 ,��a�. ;� g '� � � � LOT 36 N��i a � \ __ -�0•�L. � ` 98,3a __ 3�j� . TYPE B� , •�^� • -_ � C �Q�� � PAD=t Q�S,G�. �Q`� ' �. r'} �1� ;; � ` L,�j G,� v '�>� � i�� � 9 .1 B -�` '�G��J�' , �' '�.' �,�G. � ` iYPE1 (, �; ,� � . � , ��J � .�� , v °J' � � '� .'� - G: � • • ,\ .1 •L6� ` . Q� � k� `pj � 'tJ - 1 ` a . , , - r o� . � � s o � , - � � � , .1 � _,o�s � ,� ; n .; z _�6 a �. `\ �� �__-� � �o d�` � . ��"�v � �O o 1 a � • ,,`�' � � ' cJ o �� �,n. � .'� F=99..6Q�. ' uc \ `` ,o . J ^ • o `o ^n ' r ^ � �----- , � � 9 � ` LOT �`3; . � .a _ C�� ^ C�`• ` � _ _ _ ' PAD�8.9 'o,. � ..\ �,�� ' ^t �' �_ r- -�J `,-7�- _ �9 p �� iYPE B' ' � _y' � . ' �� . '�g _ --7 ` ,�--� °� r--_ __ 0 �` � , •. ,_�� F 8 �� " � " , '16 .0) ��J ^ M� /^ v �. � �4'. „ ' �� ' • ,.�, �� ^ ��g O '�A �� • -, � ,,,.�', . . r' �0' �� cJ � '�� �F=101.70 �FF=100.90 �C0.20 J �� i � 4 ,a� , � ' � '�p� ,\C�� rF=�02-SLI� LOT 11 LOT 10 L'CT 9 �• � ' ' ` ' i PAD=700. i . �� i �� . • LCT. 12 � AD=1 O1.0 pAD=99-S I F=100�0 � '� ' � - � �� � � ��'- :F=103.6 A0=1'0.1_9 y TYPE Art� TY?E A c p LQT 8 91 Tb� , . ,^,��' - ✓ . L07 13 TYPE A � � �1 I �� pAD=99.5 � .I "• � r� � �• 05.0 AQ 102.4 � � � \ I I O � � � � ' �g'`--99J0 ' - J � ��� � rr=1 E.A ._'� � � � � TYPti A i 1�'' �1 'LOT 25 /, � 1 •, LOT 14 � � � �• i � - e y�, A�=99.0 _ � � FFc106.s a0=iO4.3 ` ^•6 _:��,��p ''� � { �� 4J P�E B , h� �„ � � � LQr 15 TYPE A � � � y� ., �r h � \ AD=10.�.7 ^ „'�� � � -a ,. � 1 r42 i ' � i , p1�j• . � �r TYPE �( 1y\ ;�' ���o ,O} �v�p, � � " k �� � k 6 Or0 ;�,� ` 'y � �/y c_ \ - _ ly '� , 'O � o • t p� � � '�3 k �� FF=100.30� g. m � � � � � � �^ I � O g. '"�� LOT 24�', i� �t0� `� � ��� � , �� L „� �� i�. ro 4S� . PAD=99.6 , 0 00� � .�' �:r � > � � � =� ,� � TYPE e {�� � �� 1 � ��'� • • � ^ �F=105.70 =105.00 �', i� , v i � u"� 1 �o� • � 0 � '�" FF=106.2 � r J ! �r � '.I � � a `l LOT 5 LOT 6 104:�0 �O r '� _, , �� ' � � LOT d PAD=105.0 f �_ �o k , - � � -� • PAD=104.3 i � �' `�.r ,� � . � �: , ' fF=107. PAD=105.5 ' �Q)'PE B I 8 LOT 7•. ,.• , - 1�A ..' I o � o��� �� � -: ` LOT 3 TYPE 8 `;^rl.• �i� PAD=1 60 � •� �i�+ FF=102.40 g. � '. �' � � .. C ,� J�: =� \ j�: �� FF=107.7 A0=106 � r� O' " --J nP�� "• � � � ?� ` LOT 23 -_ a ��'. „ \�� . � `� Q LOT� 2 � TYPE 8 ��.� �� � J Q r�• a` ' P 7 00.7 ,n^��' � i `'� �0 \o`T;� ��=�� � FF=t`48.0 AD=107c� , ��v I � ---- �� � �a `� ^ � � `���� 1 , LoT t rr�� a. _ -< � ��Q• 'f , '° -,'' � � A�=r o7.s ^, - _\"' � o - -_ . � � ,� �.,�,? � , • ��: � ,� � � NPE 8 � , ,�' � �' '� / . �' O �d,'�' \ 1 �O ` ,� ' .- eiS�EN� .� . a� r� , n ��C , � . �� J ' ..�nT°��° r�. 99. � a� 4 � :� � FORIVI R405-2014 � FLI�RIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method -r�•, Project Name: 1941A sf ADS Buildefi�lame: Lennar Homes street: 36006 Stable Wilk Avenue � Perrri�t office: Ci �jf�phyrhills City,State,Zip. ,FL, Permit Number ri�C7 Owner� Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County�� Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area � a.Concrete Block-Int Insul,Exterior R=4 1 1454.60 ftz 2. Single family or multiple family Single-family b.Frame-Wood,Ad'acent �, 1 R=11.0 506.78 ftz 3. Number of units,if multiple family 1 c.N/A R= ftz 4 Number of Bedrooms 4 d.N/A R- ft= 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area 2 a.Under Attic(Vented) R=30.0 1936.00 ft 6. Conditioned floor area above grade(ftz) 1936 b.N/A R= ftZ Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ 11 Ducts R ftz 7 Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 a. U-Factor: Dbl,U=0.54 101.00 ft� • SHGC� SHGC=0.31 b. U-Factor• Dbl,U=0.56 33.33 ft� 12.Cooling systems kBtu/hr Efficiency SHGC• SHGC=0.32 a.Central Unit 34.2 SEER:15.00 , c. U-Factor Dbl,U=0.56 23.00 ft= SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U=Factor• N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC� 0.308 14.Hot water systems a.Electric Cap:40 gallons 8. Floor Types (1936.0 sqft.) Insulation Area . EF•0.950 a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features b N/A R= ftZ None c.N/A R= ftz 15.Credits Pstat Glass/FloorArea: 0.081 Total Proposed Modified Loads: 61.81 pASS Total Baseline Loads. 62.65 I hereby certify that the plans and specifications covered by Review of the plans and 0�'���T.q�,�.� . this calculation are in compliance with the Florida Energy specifications covered by this �4. ; � ''a.�.� t7,��;, Code. calculation indicates compliance v�'��;,r,.�`�, �,�r._^`;.•����,'�+Y„ �' �ave �Gol�cG� with the Florida Ener Code. �+ 1urrr� ''��.•.,�����'.�`'+�,ti O 9Y . ..�� ��,,::+�t.. PREPARED BY. Before construction is completed c i •;� '�" '° � DATE: this building will be inspected for �: �l�i°" ;� ki� compliance with Section 553.908 * ��' � �, - I hereby certify that this building,as designed, is in compliance Florida Statutes. ;�,i,� , " ��� with the Florida Energy Code. a1]{�y�'i''i�' CHECKED AUG 0 8 OWNER/AGENT. �UILDING OFFICIAL. DATE: DATE. � - Compliance requires certification y the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. I - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. 8/7/2017 2:03 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 C � • FORM R405-2014 � FL�RIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941A sf ADS Builder Name: Lennar Homes street: 36006 Stable Wilk Avenue Permit office: City of Zephyrhills City,State,Zip: ,FL, Permit Number Owner• Lennar Homes .lurisdiction: 611600 Design Location: FL,Tampa County�� Pasco(Florida Climate Zone 2) 1 New construction or existing , New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area � 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 1454.60 ftZ b.Frame-Wood,Adjacent R=11.0 506.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ftz 4 Number of Bedrooms 4 d.N/A R= ftz 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area Z a.UnderAttic(Vented) R=30.0 1936.00 ft 6. Conditioned floor area above grade(ftZ) 1936 b.N/A R= ft� Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ 11.Ducts R ftz 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 a. U-Factor• � Dbl,U=0.54 101.00 ftZ SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ftZ 12.Cooling systems kBtu/hr Efficiency SHGC• SHGC=0.32 , a.Central Unit 34.2 SEER:15.00 c. U-Factor• Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor� N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 SHGC� Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC� 0.308 14 Hot water systems a.Electric Cap:40 gallons 8. Floor Types (1936.0 sqft.) Insulation Area EF 0.950 a.Slab-On-Grade Edge Insulation ,R=0.0 1936.00 ftZ b. Conservation features b.N/A R= ftZ None c.N/A R= ftz 15.Credits Pstat Glass/Floor Area: 0 081 Total Proposed Modified Loads 61.81 pASS Total Baseline Loads: 62.65 I hereby certify that the plans and specifications covered by Review of the plans and �'����T,��. . this calculation are in compliance with the Florida Energy specifications covered by this �1.� � '" =- ;�Q�. `. Code. calculation indicates compliance �. �:,,;'' , �:s;.-��,.��1��. � � :,-:•r�.•�4.� �a�e �/,��G/I with the Florida Energy Code. �rrra ' � ,x O. _ PREPARED BY� p �, "' �"'���� W� �� Before construction is com leted w�i � DATE. this building will be inspected for t�,g �����: ;'� : � ;.. compliance with Section 553.908 ,; ��:`° : _„ Florida Statutes. ;� . • :� X �: I hereby certify that this building,as designed, is in compliance �C � . �g. with the Florida Energy Code. dD yyE`;� OWNER/AGENT. BUILDING O FI . DATE: DATE. ' r - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. � -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1..1 and an envelope leakage ' test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. 8/7/2017 2:03 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 . ' FORIVI R405-2014 ' FLORIDA ENERGY EFFICIENCY CODE .FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941A sf ADS Builder Name: Lennar Homes i screet: 36006 Stable Wilk Avenue Permit office: City of Zephyrhills City,State,Zip: ,FL, , Permit Number Owner Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ftz b.Frame-Wood,Adjacent R=11.0 506.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ftZ , 4. Number of Bedrooms 4 d.N/A R= ftz 5. Is this a worst case? Yes �0.Ceiling Types (1936.0 sqft.) Insulation Area x a.Under Attic(Vented) R=30.0 1936.00 ft 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ftz Conditioned floor area below grade(ftz) 0. c.N/A R= ftZ 11 Ducts R ftz 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 • a. U-Factor Dbl,U=0.54 101.00 ftz SHGC� SHGC=0.31 b. U-Factor• Dbl,U=0.56 33.33 ftz 12.Cooling systems kBtu/hr Efficiency SHGC• SHGC=0.32 a.Central Unit 34.2 SEER:15.00 c. U-Factor Dbl,U=0.56 23.00 ftZ SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor• N/A ftz a.Electric Heat Pump 32.8 HSPF:8.50 SHGC Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.308 14 Hot water systems a.Electric Cap:40 gallons 8. Floor Types (1936.0 sqft.) Insulation Area EF•0.950 a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftz b. Conservation features , b.N/A R= ft2 None c.N/A R= ftZ 15 Credits Pstat Glass/FloorArea: 0.081 Total Froposed Modified Loads 61.81 pASS Total Baseline Loads: 62.6� I hereby ce�tify that the plans and specifications covered by Review of the plans and ��'T�E S�"'.q?.�. -. this calculation are in compliance with the Florida Energy specifications covered by this 4 , �-.;•, 0,�,. .. Code. calculation indicates compliance ,r,���;,,�'` , b:;,�`�a���� ,��„ ` �ave �/,��G/- with the Florida Energy Code. �+ jrrrr.���'��-, .;.;:��y�.s�'-�,,,,, O 'PREPARED BY w< « Before construction is completed w`�i � " _ �+ r� �. .+��,. .._. � DATE: this building will be inspected for � l,rG;,. :'� compliance with Section 553.908 * '� ° � ,,. .� � I hereby certify that this building,as designed, is in compliance Florida Statutes. �,i, '_,. ����: with the Florida Energy Code. ��I?yWE`� � OWNER/AGENT: BUILDING FIC L. DATE. � DATE: � - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. ' � - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. 8/7/2017 2:03 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 � � FORM R405-2014 PROJECT Title: 1941A sf ADS Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned/1rea: 1936 Lot# Owner Lennar Homes Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office. Cross Ventilation: No County� Pasco Jurisdiction: Whole House Fan: No City,State,Zip: , Family Type: Singie-family FL, New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL TAMPA INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Entire House 1936 16360.3 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 master 210 1680 No 2 1 1 Yes Yes Yes 2 family rm 341 3171.3 No 0 1 Yes Yes Yes 3 cafe 161 1288 No 0 1 Yes Yes Yes 4 kit 182 1692.6 Yes 0 1 Yes Yes Yes 5 bdrm2 147 1176 No 1 1 1 Yes Yes Yes 6 bdrm3 149 1192 No 1 1 1 Yes Yes Yes 7 bath2 61 488 No 0 1 Yes Yes Yes 8 bdrm4 149 1192 No 1 1 1 Yes Yes Yes 9 o wic 104 832 No 0 1 Yes Yes Yes 10 privy 24 192 No 0 1 Yes Yes Yes 11 o bath 117 936 No 0 � 1 Yes Yes Yes 12 laundry rm 100 800 No 0 1 Yes Yes Yes 13 foyer 148 1376.4 No 0 1 Yes Yes Yes 14 hall 43 344 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio master 29.5 ft 0 212.3 ftz ___ 0 0 1 2 Slab-On-Grade Edge Insulatio family rm 14.5 ft 0 340.8 ft2 ___ 0 0 1 3 Slab-On-Grade Edge Insulatio cafe 25.5 ft 0 161 ft2 —__ 0 0 1 4SIab-On-Grade Edge Insulatio - kit 13.5 ft 0 182.3 ftz ___ 1 0 0 8/7/2017 2:03 PM EnergyGauge�USA-FlaRes2014 Section R405 4 1 Compliant Soffinrare Page 2 of 6 i � 1 FORM R405-2014 FLOORS . # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab-On-Grade Edge Insulatio bdrm2 10.5 ft 0 146.8 ftZ ___ 0 0 1 6 Slab-On-Grade Edge Insulatio bdrm3 13.5 ft 0 148.5 ftz �__ 0 0 1 7 Slab-On-Grade Edge Insulatio bath2 5.5 ft 0 60.5 ftZ �__ 1 0 0 8 SIab-On-Grade Edge Insulatio bdrm4 35.5 ft 0 148.5 ftz —__ 0 0 1 � 9 Slab-On-Grade Edge Insulatio o wic 21 ft 0 104 ftz ___ 0 0 1 10SIab-On-Grade Edge Insulatio privy 1 ft 0 24 ftZ ___ 1 0 0 11SIab-On-Grade Edge Insulatio o bath 10.5 ft 0 117.3 ftz e__ 1 0 0 12SIab-On-Grade Edge Insulatio laundry rm 9 ft 0 100 ftz ____ 1 0 0 13SIab-On-Grade Edge Insulatio foyer 22.5 ft 0 147.5 ftz —__ 1 0 0 14SIab-On-Grade Edge Insulatio hall 2 ft 0 42.5 ftz —__ 0 0 1 ROOF I � Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor Tested Tested Insul. (deg) 1 Hip Composition shingles 2165 ftZ 0 ftz Medium 0.85 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1936 ftZ N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) master 30 Blown 210 ft2 0.1 Wood 2 UnderAttic(Vented) family rm 30 Blown 341 ftZ 0.1 Wood 3 UnderAttic(Vented) cafe 30 Blown 161 ft� 0.1 Wood 4 Under Attic(Vented) kit 30 Blown 182 ftZ 0.1 Wood 5 Under Attic(Vented) bdrm2 30 Blown 147 ftz 0.1 Wood 6 UnderAttic(Vented) bdrm3 30 Blown 149 ftZ 0 1 Wood 7 UnderAttic(Vented) bath2 30 Blown 61 ftz 0.1 Wood 8 UnderAttic(Vented) bdrm4 30 Blown 149 ft� 0.1 Wood 9 Under Attic(Vented) o wic 30 Blown 104 ftZ 0.1 Wood 10 Under Attic(Vented) privy 30 Blown 24 ft2 0.1 Wood 11 Under Attic(Vented) o bath 30 Blown 117 ftz 0 1 Wood 12 Under Attic(Vented) laundry rm 30 Blown 100 ftz 0 1 Wood 13 UnderAttic(Vented) foyer 30 Blown 148 ft2 0 1 Wood 14 UnderAttic(Vented) hall 30 Blown 43 ftZ 0.1 Wood 8/7/2017 2:03 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 3 of 6 Y � FORM R405-2014 , WALLS � r Adjacent SR�Ce Cavity Width Height Sheathing Framing So{ar Selo w _ 1 S=>SW Exteriar Concrete Block-Int Insul master 4 1 12 6 8 0 100.0 ftz 0 0 0.6 0 �2 W=>NW F�terior Concrete Block-Int tnsul master 4 1 17 0 8 0 138A ft2 0 0 0.6 0 ^ 3 S=>SW Exterior Cancrete Block-Int Insul family rm 4 1 14 6 9 A 135.3 ft2 0 0 0.6 .0 _4 E=>SE E�cterior Cancrete Block-Int Insul cafe 4 1 12 0 8 4 96_0 ft2 0 0 0.6 d ^ 5 S=>SW Exterior Goncrete Block-Int Insul cafe 4 1 13 6 8 0 108.0 ft2 0 0 0.6 0 _6 E=>SE �acterior Concrete 81ock-lnt Insul kit 41 13 6 9 4 126.0 ft2 0 0 0.6 0 _ 7 E=>SE Exterior Goncrete Block-Int Insul bdrm2 4.1 1 p 6 B 0 84.0 ftz 0 0 0.6 0 ^ 8 E=>SE Exferior Concrete Blocic-tnt Insul bdrm3 4.1 93 6 8 Q 108.d ft2 0 0 d.6 d _9 E=>SE Exteriar Concrete Block-Int Insul bath2 4.1 5 6 B 0 A4.0 ftZ p 0 0.6 0 ^10 N=>h!E Extariar Concrete Block-tnt insul bdrm4 4.i 13 6 8 0 1 d8.0 ftz d 0 0.6 0 _11 E=>SE Exterior Gancrete Block-Int Insul bdrm4 4 1 11 Q 8 p 88.0 ft2 0 Q 0.6 0 _12 W=>NW Exteriar Concrete Black-Int tnsul bdrm4 4 1 'S 1 0 8 0 88.0 ft2 Q 0 0.6 0 ^13 N=>NE Garage Frame-Wood o wic 11 28 4 8 0 226.7 ftz p 0.25 0.01 0 �14 W=>NW E�cterior Go�crete BEoc3c-Int lnsul o wic 41 8 0 8 0 64.Q ftz 0 0 0.6 Q �15 W=>NW Exterior Concrete Block-Int Insul o bath 4.1 10 6 8 0 84.0 ft2 0 0 0.6 0 _16 N=>NE Garage Frame-Wood laundry rm 11 17 5 8 0 139.3 ft2 0 0.25 O.Q1 0 �17 N=>NE Exterior Cancrete Block-Int Insul foyer 4.1 5 0 9 4 46.7 ft= 0 0 0.6 0 _18 W=>NW Garage Frame-Woad foyer 11 15 1 9 4 140.8 ft2 p 0.25 0.01 0 ,�19 W=>NW Exterior Cancrete Block-Int Insul foyer 4.1 2 5 9 4 22.6 ftz 0 0 0.6 0 �20 W=>NW Exterior Goncrete Block-Int Insul ha1l 4 1 2 0 8 4 16.0 ftz Q 6 0.6 0 DOORS # Ornt Doar Type Space Storms U-Value Width Height Area F't !n Ft In 1 N=>NE Woad iaundry rm None .4 2 8 6 8 17.8 ftz 2 N=>NE Insulated foyer None .2 3 6 8 20 ftZ WINDOWS Qrientation shown is the entered orientatian{_> changed to Worsk Gase. / Walf Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening i S->SW 1 Metal Low-E Double Yes 0.54 0.31 23A ft2 1 ft 0 in 0 ft 11 in Nane None 2 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 46.0 ftZ 1 ft 0 in 0 ft 11 in None None 3 S=>SW 5 Metai Low-E Double Yes 0.56 0,32 33.3 ftz 2 ft Q in 0 ft 6 in None None 4 E=>SE 7 Metal Low-E Double Yes 0.54 0.31 16.0 ftZ 1 ft 0 in 0 ft 11 in None None 5 E=>SE 8 Metal Low-E Doubte Yes 0.54 0.31 16A ft2 1 ft 0 in 4 ft 11 in Mone None 6 N=>NE 10 Metal Low-E Double Yes 0.56 0.2$ 23.0 ft2 1 ft 0 in 4 ft 2 in None None 8/7/2017 2:03 PM EnergyGaugeC�USA-FlaRes2014 Seckion R405.4 1 Compliant 3oftware Page 4 of 6 FORM R405-2014 . GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wail Insulation � 1 416ftZ 416ftZ 43.7ft Sft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000322 1636 89.82 166.91 .2416 6 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 32.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity . Air Flow SHR Block Ducts 1 Central Unit Split SEER:15 34.2 kBtu/hr 1026 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ffz DUCTS / —Supply-- --Return-- Aif CFM 25 CFM25 HVAC# \/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 387.2 ft family rm 96.8 ft2 Proposed Qn laundry rm —cfm 58.1 cfm 0.03 0.50 1 1 8/7/2017 2:03 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2014 - , TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb Mar A r Ma X Jun X Jul Au X Se Oct Nov Dec Heating f X�Jan f X�Feb f X�Mar f �APr f �May � �Jun 4 �Jul ��Au9 4 �SeP f �Oct f X�Nov f X�Dec Ventin [ Jan [ Feb [X Mar [X A r [ Ma Jun [ Jul Au [ Se [X Oct [X Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 � PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(VVEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 8/7/2017 2:03 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 1 � FO RM.R405-2014 - � � ENERGY PERFORMANCE LEVEL (EPL) � DISPLAY CARD � - ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. „ FL, 1 New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ftZ , b.Frame-Wood,Adjacent R=11.0 506.78 ft 3. Number of units,if multiple family 1 c.N/A R= ftZ 4 Number of Bedrooms q d.N/A R= ftz 10.Ceiling Types Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1936.00 ftZ 6. Conditioned floor area(ftz) 1936 b.N/A R= ftz 7 Windows" Description Area c.N/A R= ftZx a. U-Factor• Dbl,U=0.54 101.00 ftz 11 Ducts R ft a.Sup�Attic,Ret:family rm,AH:laundry rm 6 387.2 SHGC• SHGC=0.31 b. U-Factor Dbl,U=0.56 33.33 ftz SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency c. U-Factor• Dbl,U=0.56 23.00 ftx a.Central Unit 34.2 SEER:15.00 SHGC' SHGC=0.28 d. U-Factor: N/A ftZ 13.Heating systems kBtu/hr Efficiency SHGC• a.Electric Heat Pump 32.8 HSPF:8.50 Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC• 0.308 8. Floor Types ' Insulation Area 14.Hot water systems Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftZ a.Electric EF•0.95 b.N!A R= ft2 c.N/A R= ftZ b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building ' �S Construction through the above energy saving features which will be installed (or exceeded) ,�0��� �r`�r�.� , in this home before final inspection. Otherwise, a new EPL Display Card will be completed ���rt�j'',, ,+_;_;��.; �, based on installed Code co pliant features. h +ar,r.�"��•::�.�:�:;;•�'�» 4 - r� _.. --��°'`'" ..'.. ::'' � F� -._.:Sti,�i,.. ..... .._.b...- C )..; Builder Signature: Date• 08/07/17 �. ;� � _. �' Address of New Home: 6006 Stable Wi1k Avenue City/FL Zip. Zephyrhills, FL 33541 �;�, ��;� o��� . .. "Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1 3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/7/2017 2:04 PM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Buildin Anal SIS Job: 1941A sf ADS • g Y Date: 81712017 En fire Ho us e By: Dave � Bayonet Plumbing Heating and Air ' o - s s I For� Lennar Homes . , , , ! - • � � s Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 � Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb (°F) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • z o , Component Btuh/ft Btuh /o of load Walls 5.6 7030 24.6 ���5 Glazing 30.2 4739 16.6 wens DOofs 23.5 466 1.6 nr�tration Ceilings 1.3 2429 8.5 Floors 3.5 6726 23.5 Infiltration 2.8 3996 14.0 D ucts 3223 11.3 Plplftg 0 0 Glazing Humidification 0 0 Fi°°`5 Other � Ventilation � � Ceilings Adjustments 0 Total 28608 100.0 e • • Component Btuh/ftZ Btuh % of load Walls 2.8 3497 13.4 walls Glazing 56.9 8927 34.2 Internal Gains ' Doors 18.4 365 1.4 Ceilings 1.7 3358 12.9 Floors 0 0 0 Infiltration 0.6 880 3.4 D ucts 3621 13.9 Ventilation 0 0 . oucts Internal gains 5455 2p.g Glazing BloWef 0 0 Infiltration Adjustments 0 Total 26103 700.0 Other Ceilings Latent Cooling Load=4171 Btuh Overall U-value= 0.103 Btuh/ftz-°F Data entries checked. ,�, wri htsoft` 2077-Aug-0713:59:06 ��� 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 .th CBA27UHE AH's\1941A sf ADS template 3ton.rup Calc=MJS Front Door faces: N , Pro ect Summar Job: 1941A sf ADS � y . Date: 81T/2017 En fire Ho us e By: Dave ' � Bayonet Plumbing Heating and Air ' � - � s For: Lennar Homes Notes: 2017 ! - • � s Weather� Tampa InternationalAP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F . • Design TD 39 °F . Design TD 16 °F Daily range L - Relative humidity 50 % Moisture difference 55 gr/Ib , Heating Summary Sensible Cooling Equipment Load Sizing Structure 25385 Btuh Structure 22481 Btuh Ducts 3223 Btuh Ducts 3621 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 28608 Btuh � Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 26103 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 3525 Btuh D ucts 646 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1936 1936 Equipment latent load 4171 Btuh • Volume(ft') 16360 16360 Air changes/hour 0.34 0.18 Equipment Total Load (Sen+Lat) 30273 Btuh Equiv.AVF(cfm) 93 49 Req. total capacity at 0.85 SHR 2.6 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-036-230-21 Cond 14HPX-036-230-21 AHRI ref 10258589 Coil CBA27UHE-036-230"++TDR AHRI ref 10258589 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 29580 Btuh Heating output 32800 Btuh @ 47°F Latent cooling 5220 Btuh Temperature rise 25 °F Total cooling 34800 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.042 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.86 Capacity balance point=29 °F Backup: Na n/a � Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ��-�- wrightsoft" Rlght-Sulte�Universal 2017 17.0.23 RSU05714 2017-Aug-07 1 Pa9e 6 ...th CBA27UHE AH's\1941Asf ADS template 3ton.rup Celc=MJB Front Door faces: N r , � . Manual S Compliance Report Job: 1941A sf AD$ Date: 8/7/2017 r En tire Ho us e By: Dave Bayonet Plumbing Heating and Air ' • - • � For: Lennar Homes • • a s e Design Conditions Outdoor design DB� 91.3°F Sensible gain: 26103 Btuh Entering coil DB. 75.6°F Outdoor design WB. 77.3°F Latent gain: 4171 Btuh Entering coil WB• 62.8°F Indoor design DB� 75.0°F Total gain: 30273 Btuh Indoor RH. 50% Estimated airflow` 1200 cfm Manufacturer's Performance Data atActual Design Conditions Equipment type: SpIitASHP Manufacturer� Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230'++TDR _ Actual airflow: 1200 cfm Sensible capacity: 29070 Btuh 111% of load Latent capacity� 5130 Btuh 123% of load Total capacity� 34200 Btuh 113% of load SHR: 85% • . o Design Conditions Outdoor design DB. 30.8°F Heat loss 28608 Btuh Entering coil DB. 69.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230"++TDR Actual airflow: 1200 cfm Output capacity: 32800 Btuh 115% of load Capacity balance: 29 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer� n/a Model: n/a+n/a Actual airflow: 1200 cfm Output capacity� 0 kW 0% of load Temp. rise: 0 °F � Meets are all requirements ofACCA Manual S. .�. wri htsoft�� 2017-Aug-0713:59:06 �� ' 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 .th CBA27UHE AH's\1941A sf ADS template 3ton.rup Calc=MJB Front Door faces: N \ • CITY OF / / I I BUILDING ZEPHY.RHILLS DEPARTMENT OF ADDITION OR CORRECTION ' � • • - • ADDRE55 DATE PERMIT�, .�� Cv ' ,l�-� G - � (� THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before e job wiil be accepted. �G�r �t _ _. It is unlawful tor any Carpenter,contractor,aui�der,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any paR of the woric with flooring,lath,earth or other materiai,until the proper inspector has had ample time to approve 780-0020 FOR RE-INSPECTION the instaliation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR 4 CITY OF / / / / BUILDIN� ZEPHYRHILLS DE�ARTMENT OF ADDITION OR CORRECTION � � � � • ADDRE55 ' ����� ^ DATE PERMIT�/. - S' w.. /�_�/ -- /�d� THIS JOB HAS NOT BEEN COMPLETED. The following additions or correction�shall be made before the job will be accepted. � l�v� �L� �' ��� �'�� � �'��o�:���/� � �J� r�a��_1e��(Av ��m w 5 It is unlawful tar any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be wvered,any part of the worlc with flooring,lath,earth 780-0020 FOR RE-INSPECTION or other material,until the proper inspector has had ample time to approve the installation. � OFFICE HOURS 7.30AM-4:30 PM MON.-FRI. INSPECTOR _ �