Loading...
HomeMy WebLinkAbout17-18904 CITY OF ZEPHYRHILLS , . ; 5335-8TH STREET � (sis)�so-oo20 18904 Bl1ILDIIVG PERNiIT SINGLE FAMILY RESIDEf�TIAL PERMIT INFORMATION � LOCi4TION INFORMATION Permit#:18904 Issued: 10/06/2017 Address: 37853 PRAIRIE ROSE LP Perrr�it Type: GENERAL BUILDING PERMIT ZEPHYRHILLS, FL. Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: � Cost: 188,012.85 Total Fees: 9,408.89 Subdivision: WALNUT GROVE TOWNHOMES Amount Paid: 9,408.89 Date Paid: 10/06/2017 Parcel Number: 15-26-21-0210-00000-0230 CONTRACTOR INFORMATION OWNER INFORMATION Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD MOBILE HOME SVC INC Addr: 4209 GALL BLVD Address: 38930 BUTTERFIELD LN ZEPHYRHILLS, FL. 33542 ZEPHYRHILLS FL 33542 Phone: (813)377-7395 Lic: Phone: 813-973-5250 Work Desc: CONSTRUCT TOWNHOME 1,669 SQ FT APPLICATION FEES BUILDING FEE 850.09 ELECTRICAL FEE 169.88 PLUMBING FEE 113.25 MECHANICAL FEE 79.28 SEWER CONNECTION RESIDEN" 2,010.00 WATER CONNECTION RESIDENI 641.00 WATER METER RES 3/4" 473.78 WATER METER RES 3/4" 0.00 FIRE PLAN REVIEW FEES 104.20 FIRE INSPECTION FEES 12.50 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES TOWNHOMES 769.56 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 �,�; `,(` �r! �-Z(.. � �' �j .���ft..�`�C� i`�:s''" � ) I Ls� � Ins ections Re uired FOOTER 2 D ROUGH PLUMB MIS INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commenceenent may result in your paying twice for improvements to your properly. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. �'�-�-r� CONTRACTORS IGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIFtED PROTECT CARD FFtOM WEATHER j • V Single Family I�welling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. I , 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. 4. Tie in surve re uired before ourin concrete. I' Y q P g 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. 9. No electric, plumbing, mechanical, or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. � 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. A112008 N.E.C. Codes will be enforced. 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 22. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 5�'Edition � R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008) � • 7 �� ; PASCO �OUN1'Y, �FLt�R1�A, � " � Permlt No. l ��p T Date Permitted ,�Tv� Buiider Name/Owner Name (,IJ�'C�1��Ct�t�'C Gontrol# County Parcel No. �,tr�(a-2(- �d L��l�^ 4 SubDtv: �����_���J}'� AddresstLocatlon J� 7/�'}�� �rR��E'- ,�� � GtassificatloM'ype oP Use �L11-tJ�'��� TRANSPQRTATtON IMPACT FEE � Rate: Sq.Ft Un1t: ���� Exempt [�Yes ❑ No Ho�r Determined ' Impact Fee Amount $. �Jr�a�Z � Zane fVo. TA2: SCHOOL IMPACT FEE � / Account (05�) Stngle-Family Detached House Amount $ /�" , (057) Mo63te tiome {058) Other Restdential 123) Coitection Fae Exempt [�Yes [�Na FCow Determtned PARKS AEtD RECREATION FEE land Account Land Credit Land Totat Recreation Accaunt Recreatian Credit �Recreation Tatal Zone TOTAL AMOUNT $ �tp`�-S� Exempt []Yes [� tJo How Determfned LtBRARY FEE Land Rccount land Credit Land Total Facitity Account Facility Credit Faci{ity Totai Exempt ❑Yes ❑ Na How Determined Tatat Amount� ; RESOURCE FEE ERU TOTAL AMOUNT ' s Pcepared By Checked By . . ; NO CERTIFtCATE OF 4GCtlPANCY WiLL BE ISSUED OR FiNAL INSPECT{C}N ; P�RFORMED UNTtL THE TOTAt,AMOUNTS�1STED HAVE � - BEEN PA►ID ANQ ; � 6tEGEfPTED FOR BY A CENTRA�PERMITTIIVG O�FtCH-OF PASCO COtlNTY � 1 S i Acknowledgement betow does not lmply acceptance of concurranae,but simply recelpt of a copy of this form,placing � �� the butiding psrmit owner on notfce of thia assessment and the coodltions of payment far same. ' i DATE RECE{VED BY k RECEIPT NO. DATE BY ; , { , t � � . . . .. ' �j � s��__ ��� _.________ � FORM R405-2014 � - FLORIDA ENERCY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Pertormance Method Project Name: R0617256 Unit 8-1 and 8-6 � Builder IVame: Buttertield street: 94o�-�e�t�t- �Z�SJ' Pra�?'�'2 �,as.e-LP Permit`office: city of zeph rhii�s City,State,Zip: Zephyrhills,FL,33542 Permit Number• f�J g0� } Owner� Typical-End Units S-1 and 8-6 Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1085.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=5.0 898.67 ftZ b.Frame-Wood,Adjacent R=13.0 186.67 ftZ 3. Number of units,if multiple family 1 c.N/A R= ftZ 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1435.0 sqft.) Insulation Area Z a.Under Attic(Vented) R=30.0 1435.00 ft 6. Conditioned floor area above grade(ft� 1435 b.N/A R= ftZ Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ 11.Ducts R ft2 7. Windows('137.0 sqft.) Descriptibn Area a.Sup:Attic,Ret:Attic,AH:ah 6 175 a.`U-Factor: Dbl,U=0.30 137.00 ft2 -.SHGC: SHGC=0.25 , b. U-Factor: �. N/A ft2 1•2.Cooling systems kBtu/hr Efficiency SHGC: . a.Central Unit 27.8 SEER:14.00 c. U-Facto���: I• - N/A ft� � SHGC: ;=' �',, 13.Heating systems kBtu/hr Efficiency ' d. U=Factor ' ° ;�" N/A ftz a.Electric Strip Heat 27.3 COP:1.00 • SHGC: �, :. Area�Weighted Ave�;7ge Overhang Depth: 1.672 ft. �-�< ��"` 14.Hot water s stems Area UVeighted;Avery'.:c�e SHGC: 0.250 Y ' a.Electric Cap:40 gallons 8. Floor Tjipes (1435:r:�'sqft.) Insulation Area EF:0.970 a.Slab-On-Gracle E'r'.ge Insulation R=0.0 1435.00 ft2 b. Conservation features b.N/A . . � ' _ R= ftZ None : c.N/A �°:;,�Y, R= � 15.Credits CF,Pstat � ' -�``'� Total Proposed Modified Loads: 46.63 pASS Glass/Floor Area: �:0 095 ;� Total Baseline Loads: 46.58 �. j���'`�:;; • f. (jrva��^ ' .. ' . � ` I�hereby�certify that the plans and specifications covered by Review of the plans and �.�'C�'�``�',��,� this�caiculation are in compliance with the Florida Energy specifications covered by this 4i � =;; ,t�� Code. '� calculation indicates compliance yi'�,�,� ;����,�, ri+ . ,�,=_" �`' 0y 'l.� s with the Florida Energy Code. � ��,;���;;� �;��- , ,rp �;'�!�,�P..6��+ . PREPARED BY: " Before construction is completed � � � DATE: os-�7-17 this building will be inspected for �,.' "`I���:�. ' � compliance with Section 553.908 �._ � '�. � I hereby certify that this building, as designed, is in compliance Florida Statutes. � .. with the Florida Energy Code. �'�`+�;p����� OWNER/AGENT: BUILDING F AL: DATE: DATE: � - Compliance requi*es certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory'-s.�aled in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accor?iance with R402.4.1.2. �I 6/27/2017 5:50 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 ,�� � FORM R405-2014 PRC}JECT • Titie: R0817256 UniE 8-3 and 8-6 Bedroams: 3 Address Type: Street Address Building Type: User Conditianed Area: 1435 Lot# Owner Typical-End U�its 8-1 and& Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Gase: No PlatBaok: Builder Name: Butterfield Rotate Angle: 0 Street: 4408 Court St Permit O�ce: Gity of Zephyrhilis Cross Ventilation: No Gounty Pasco Jurisdiction: 611604 � Whale iiouse Fan: No City,Stafe,Zip: ZephyrhiHs, Family Type: Single-family FL, 33542 NewiE�cisting: New(From Plans} � Comment: CLIMATE J lECC Design Terrip tnt Design Temp Heating Design Daily Temp � Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range i FL,Tampa FL TAMPA INTERNATt 2 39 91 70 75 645.5 54 Medium BLQCKS , Number Name Area Volume 9 Entire Unit 1435 11480 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 Master Bedroam 220 1760 No 2 1 9 Yes Yes Yes 2 Mtlt 19 152 No 0 1 Yes Yes Yes , 3 Master Bath 93 744 No 0 1 Yes Yes Yes 4 Mwic 39 312 No. 4 1 Yes Yes Yes 5 � Kitchen 156 1248 No 0 1 Yes Yes Yes , 6 Bedroam3 15Q 1200 No 1 1 1 Yes Yes Yes 7 ah 12 96 No 0 1 Yes Yes Yes 8 Laundry 40 320 R!o 4 1 Yes Yes Yes 9 Bath2 44 352 No 0 1 Yes Yes Yes 10 Bedroom2 13i 1048 Na 1 1 1 Yes Yes Yes 11 Entry 58 464 No 0 1 Yes Yes Yes 12 Hall • 79 632 No 0 1 Yes Yes Yes 13 Great Rm Dining 334 3152 No 0 1 -Yes Yes Yes ' FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Master Bedroom 30.7 ft Q 220 ft' _.__ 0 1 0 2 Slab-On-Grade Edge Insulatio Mtlt 1 ft 0 19 ftz ____ 0 1 Q 3 Stab-On-Grade Edge Insuiatia . Master 8ath 1 ft . d 93 ft2 ____ 0 1 0. 4 Siab-On-�rade Edge lnsuiatio Mwic 1 ft 0 39 ft2 _.� 0 3 0 6127t2017 5:50 AIV! EnergyGaugeC�}USA-FlaRes2094 Section R405.4 1 Gampiianf Software Page 2 of 5 i I . I • FORM R405-2014 ��� FLOORS I # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab-On-Grade Edge Insulatio Kitchen 1 ft 0 156 ftZ ____ 0 1 0 I 6 Slab-On-Grade Edge Insulatio Badroom3 14 ft 0 150 ftz ____ 0 1 0 II 7 Slab-On-Grade Edge Insulatio ah 1 ft 0 12 ft' ____ 0 1 0 I 8 Siab-On-Grade Edge Insulatio Laundry 1 ft 0 40 ft2 ____ 0 1 � 0 9SIab-On-Grade Edge Insulatio Bath2 1 ft 0 44 ft2 ____ 0 1 0 10SIab-On-Grade Edge Insuiatio Bedroom2 23.7 ft 0 131 ft' ____ 0 1 0 �I 11SIab-On-Grade Edge Insufatio Entry 5 ft 0 58 ft2 ____ 0 1 0 12SIab-On-Grade Edge Insulatio Hall 1 ft 0 79 ftz ____ 0 1 0 13SIab-On-(�rade Edge Insulatio Great Rm Dining 39 ft 0 394 ft' ____ 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Coior Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1512 ftZ 238 ft' Medium 0.65 No 0.9 No 0 18.4 ATTIC - ' V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Ful!attic Vented ' 300 '1435 ftZ N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type I 1 Urnier Attic(Vented) Master Bedroom 30 Blown 220 ft2 0.1 Wo od 2 Under Attic(Vented) Mtlt 30 Blown 19 ftz 0.1 Wood 3 Under Attic(Vented) Master Bath 30 Blown 93 ftZ 0.1 Wood 4 Under Attic(Vented) Mwic 30 Blown 39 ft' 0.1 Wood 5 Under Attic(Vented) Kitchen 30 Biown 156 ftz 0.1 Wood 6 Under Attic(Vented) Bedroom3 30 Blown 150 ft2 0.1 Wood 7 Under Attic(Vented) ah 30 Blown 12 ftZ 0.1 Wood 8 Under Attic(Vented) Laundry 30 Blown 40 ft' 0.1 Wood I 9 Under Attic(Vented) Bath2 30 Blown 44 ft2 0.1 Wood 10 Under Attic(Vented) Bedroom2 30 Blown 131 ft2 0.1 Wood 11 Under Attic(Vented) Entry 30 Blown 58 ftz 0.1 Wood 12 -Under Attic(Vented) Hali 30 Blown 79 ft2 0.1 Wood 13 Under Attic(Vented) Great Rm Dining 30 Blown 394 ft� 0.1 Wood li 6/27/2017 5:50 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 3 of 5 I ' � FORM R405-2014 WALLS � Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w _ 1 N Exterior Concrete Block-Ext In3��ster Bedro 5 14 8 8 0 117.3 ftz 0 0 � 0.3 0 _2 E Exterior Concrete Biock-Ext In�d�ster Bedro 5 8 0 8 0 64.0 ftZ 0 0 0.3 0 _3 W Exterior Concrete Block-Ext In3r6�ster Bedro 5 8 0 8 0 64.0 ftz 0 0 0.3 0 _4 W Exterior Concrete Block-Ext Ins�edroom3 5 14 _ 0 8 0 112.0 ft2 0 0 0.3 0 _5 S Exterior Concrete Block-Ext Ins�edroom2 5 12 0 8 0 96.0 ftZ 0 0 0.3 0 _6 W Exterior Concrete Block-Ext Ins�edroom2 5 11 8 8 0 93.3 ft2 0 0 0.3 0 7 S Exterior Concrete Block-Ext Insul Entry 5 5 0 8 0 40.0 ftZ 0 0 0.3 0 _S N Exterior Concrete Block-Ext in�'ndeat Rm"Din 5 14 0 8 0 112.0 ftz 0 0 0.3 0 _9 W Exterior Concrete Block-Ext In�deat Rm Din 5 25 0 8 0 200.0 ftZ 0 0 0.3 0 _10 S Garage Frame-Wood Entry 13 11 8 8 0 93.3 ft2 0 0 0.01 0 _11 S Garage Frame-Wood Bath2 13 6 4 8 0 50.7 ft2 0 0 0.01 0 _12 S Garage Frame-Wood Laundry 13 5 4 8 0 42.7 ftZ 0 0 0.01 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated Entry None � .35 3 6 8 20 ftz 2 N Insulated Great Rm Din None .35 3 6 8 20 ft2 ' 3 S Insulated Entry � None .35 2 8 6 8 17.8 ftZ WINDOWS Orientation shown is the entered,Pro osed orientation. / U,�ail Overhang V # Ornt (D Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 TIM Low-E Double Yes 0.3 0.25 30.0 ftZ 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 2 W 4 TIM Low-E Double Yes 0.3 0.25 15.0 ftz 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 3 S 5 TIM Low-E Double Yes 0.3 0.25 20.0 ft' 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 4 W 6 TIM Low-E Double Yes 0.3 0.25 15.0 ftZ 9 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 5 N '8 TIM Low E Double Yes 0.3 0.25 12.0 ft' 8 ft 8 in 1 ft 2 in Drapes/blinds _ Exterior 5 6 W � TIM Low-E Double Yes 0.3 0.25 15.0 ftZ 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5 7 W � TIM Low-E Double Yes 0.3 025 30.0 ftZ 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 GARAGE � � # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wail Insulation 1 234 ftZ 234 ftz 64 ft 8 ft 1 , ' INFILTRATION # Scope Method . SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1339.3 73.53 138.28 .2669 7 � 6/27/2017 5:50 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 � . a � � , . . . � FORM R405-2014 HEATIiVG SYSTEM # System Type Subtype �Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 27.3 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 14 27.8 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60 gal 120 deg None SOLAR HOT VUATER SYSTEM FSEC Collector Storage Cert # Gompany Name System Model# Collector Model# Area Volume FEF None IVone ftZ DUCTS / --Supply---- ----Return-- Air CFM 25 CFM25 , HVAC# \� # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool � 1 Attic 6 175 ft2 Attic 75 ftZ Default Leakage ah (Default) (Default) 1 1 ' TEMPERATURES Programable Thermo:>tat:Y Ceiling Fans: , Coolin Jan Feb Mar A r Ma X Jun X Jul X Au X Se Oct Nov ]Dec Heating f X�Jan f X�Feb f X�Mar f �APr f �MaY 4 �Jun 4 �Jul f �Au9 4 �SeP f �Oct �X�Nov EX]Dec Ventin [ Jan [ Feb [X Mar [X A r [ Ma [ Jun [ Jul [ Au [ Se [X Oct [X Nov [ J Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 � Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 SO PM 80 SO 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 6/27/2017 5:50 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 � I � ' 9 ' . . . ' FORM R405-2014 ENERGI( PERFORIVIANCE LE\!EL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 II The lower the EnergyPerformance Index, the more efficient the home. I 4408 Court St, Zephyrhills, FL, 33542 II 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area I 2. Single family or multiple family Singie-family a.Concrete Block-Ext Insul,Exterior R=5.0 898.67 ft2 b.Frame-Wood,Adjacent R=13.0 186.67 ftz 3. Number of units,if multiple family 1 c.N/A R= ftZ 4 Number of Bedrooms 3 d•N�A R= {�z 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1435.00 ft' 6. Conditioned floor area(ft') 1435 b.N/A R= ft2 : 7. Windows*' Description Area 11 cDucts R R ftZ a. U-Factor: Dbl,U=0.30 137.00 ft2 a.Sup:Attic,Ret:Attic,AH:ah 6 175 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a.Central Unit 27.8 SEER:14.00 SHGC: d. U-Factor: N/A ftZ 13.Heating systems kBtu/hr Efficiency SHGC: � a.Electric Strip Heat 27.3 COP:1.00 Area Weighted Average Overhang Depth: 1.672 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14.Hot water systems = a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1435.00 ft EF 0.97 b.N/A R= ftz ' c.N/A R_ ft� b. Conse►vation features ' None 15.Credits CF,Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building �,����,�. Construction through the above energy saving features which will be installed(or exceeded) � ;.._� in this home before final inspection. Otherwise, a new EPL Display Card will be completed -��$"�,�'�� �=�������; s-=,==.�,., � based on installed Code compliant features. w u,;�-�`�=;?���j 4y o� Builder Si nature: � "���- - �' 9 Date: �f�� � � � � � Address of New Home: City/FL Zip: �'�, �flfj�"S�'� :. "Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient , mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. ''"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/27/2017 5:51 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 , ' " ' 37853 Prairie Rose o umn SQ. FEET PRICE UNDER ROOF: ' 1,669 $ 112.65 OTHER: - $ - VALUATION $ 188,012.85 FEE SHEET $ 755.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 850.10 ELECTRICAL: $ 169.88 PLUMBING: $ 113.25 MECHANICAL: $ 79.28 SUB-TOTAL $ 1,212.50 TOTAL $ 1,272.50 SEWER: $ 2,010.00 WATER: $ 641.00 ' IRRIGATION: $ - TOTAL: $ 2,651.00 WATER METER: $ 473.78 IRRIGATION METER FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 4,890.63 PARK IMPACT FEES $ 769.56 SIF'S: 100.0% $ - 1.0% $ - TOTAL: $ - T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 9,292.19 15-26-21-0210-00000-0230 � Pasco County Property Appraiser Page 1 of 1 I�, Data Current as Of: Weekly Archive - Saturday, September 30, 2017 Parcel ID 15-26-21-0210-00000-0230 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value BUTTERFIELD MOBILE HOME Ag Land $0 SERVICE INC Land $4,290 , 38930 BUTTERFIELD LN Building $0 ' ZEPHYRHILLS FL 33542-1677 Extra Features $0 ' Physical Address 37853 PRAIRIE ROSE LOOP ZEPHYRHILLS FL 33542-2203 Just Value $4,290 AssesSed (Non-School Amendment 1) $4,290 Legal Description (First a�ines) See Plat for this Taxable-Value $4,290 Subdivision WALNUT GROVE TOWNHOUSES PB 69 PG 054 LOT 23 OR 6544 PG�1916 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line � �Use DescriptionZ� oning—rUnits Type �P cr�e Condition �Value 1 � � 0100 SFR MPUD � 2,7�� �SF � $1.56 1 1.00 ; $4,290 Additional Land Information � ^���T FEMA Acres 0.06 Tax Area� 30ZH � Code � X � Residential Code� WGTHLPI T 1 I � Building Information - Use 00 - Unimproved (Card: 001 of OOY) � Unimproved Parcel 00 - Unimproved � Extra Features (Card: 001 of 001) __________�__.�._____._.__.._______�____. ._____ Line �Description __ _____1Year ��� __Lnits � T�^;Value _ _ _ No Extra Features Sales Historv Previous Owner: N/A �.�______^_._._._�___._. _�____._�___ Month/Year Book/Page Type � �DOR Code Condition �Amount �ti. _.__ __ �. __�_. � 08/2005 6544 / 1916 j� Warranty Deed Vacant $600,000 ------..._.. _______ _�._._-- _ 11/1981 1157 / 1702�_�� �w - � Vacant ^j $130,000 O1/1973 � ; 0707/ 0675 ( � � ^ ~C Vacant !� $0 � http://search.pascopa.com/parcel.aspx?parce1=2126150210000000230 10/6/2017 - Prairie Rose Lp IY23-Bailey Contractir►g 1,669 sq ft-Townhome- 37853 Prairie Rose Lp ' ,;SQ.'FEET PRICE - MAIN OR LIVING: ' 1,669; $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 : OTHER: - $ , �VALUATION $ , 188,012.85. - ,,FEE SHEET $ 755.00 ADDRESS $ 40:00 DRIVEWAY,.$, ,.,, 40.00 : - • " ��•BUILDING: .$.,=. . 850.10 . ELECTRICAL: $�',' 169.88, .PLUMBING:.$� ," 113.25 MECHANICAL: $__' " 79.28 SUB-TOTAL .$ � '1,212.50 TOTAL: $: �- 1,212.50, SEWER: $: _ ' _ 2,010.00 ' WATER: $ 641.00 - ,IRRIGATION: ,$" " � - • TOTAL: 'S-� 2,851.00 � 'WATERMETERi $. 473.78 IRRIGi4T,lON METER $ . ' - , •FIRE DEPARTMENT,FEES "'PLANS•TOTAL: $.: . � 104.20 INSPECTIOMTOTAL: $ 12.50 PERMIT TOTAL �TOTAL:'S.. '116.70 �PUBLIC SAFETY IMPACT FEES ` FOLICE $ 254.00' FIRE $ 273.00 � 5% $= 26.35 TOTAL: S`z 553.35 SUB=TOTAL .$� 5,007.33� PARK IMPACT'FEES S y' '769.56 ' � SIF'S: _ -- 100.0% $' ' '1.0% $ - TOTAL: S'. - � T I F'S: S _ 3,632.00' 99% $_ 3,595.68 1%.$ 36.32 � � � TOTAL: $_ 9;408.89 i � � - ' � = - � - � � . -. � ; i - � � ; .. ' „ _ _ i�l ; , ' , ' ' � _ . , . , - , ` � i , . , , : I ,' , ' � - � - � -i � I (" � f i � ' �, �f. ' • ._�.._ ' ' ' . ' "' - . _ " - _ 1 � - " " . _ ' - i . , f ' ' _-: ' � ' � _ ' " I � _ � E � -- ' , ' , ' � � I �� � �. ,i. ? '" -- . ., ' ' � �1 i . ' ' � L I " - . . � , ' , � � Pasco couNnr BUILDING CONSTRUCTION SERVICES ' ��t 8731 Citizens Drive Date: 12/29/2017 Suite 230 � -� New Port Richey, FL 34654 � 727-847-8127 ** NC�T A PERMIT *�` Receipt#: 1728045 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 1.00 1309097 $0.39 $0.39 1728045 12/29/17 Waste Condo, Multi-Family MH in Park,per Unit TOTALS: 50.39 50.39 Receipt# Paid Bv Check# CC Auth i� Cashier ID Workstation Receiat Date Amt Paid 1728045 Check 2238 2238 534 BCCCP15W 12/29/2017 $0.39 Total Payments: 50.39 Pavor Address Phone BAILEY 18904 ZHLLS 37853 PRAIRIE ROSE LP Comments: C �Ro MyReports/reports//PRODUCTION/PASCO/ReceiptPOS V4.rp1 12/29/2017 Page 1 of 1 — " ' ` 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 37853 PRAIRIE ROSE LP LT 5 Owner: BUTTERFIELD MOBILE HOME SVC INC ZEPHYRHILLS, FL. 38930 BUTTERFIELD LN Subdiv: WALNUT GROVE TOWNHOMES ZEPHYRHILLS, FL. 33542 Parcel: 15-26-21-0210-00000-0230 Work Type: 105-NEW CONST/MULTI 5+ UNIT Construction Type: NOT APPLICABLE ❑ Sprinklers I Use Classification: NOT APPLICABLE Permit Number: 18904 Date: /26/2018 � ., ISSUED . BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE