Loading...
HomeMy WebLinkAbout17-18982 CITY OF ZEPHYRHILLS 5335-8TH STREET '� � (813)780-0020 18982 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL - ' PERMIT INFORMATION - � � LOCATION INFORMATION Permit#:18982 Issued: 10/25/2017 Address: 6477 PADEN WHEEL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 342,230.70 Total Fees: 11,736.69 Subdivision: SILVERADO Amount Paid: 11,736.69 Date Paid: 10/25/2017 Parcel Number: 05-26-21-0070-00400-0020 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SNGLE FAMILY 3,038 SQ FT APPLICATION FEES BUILDING FEE 1,321.33 ELECTRI AL FEE 273.83 PLUMBING FEE 182.55 MECHANICAL FEE 127.79 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 � � � .3��`� � �L� ��� �� �z �� Ins ecti s Re uired FO TER 2ND R UGH PLUMB MIS INSULATI N CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or frst reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this properly that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. �� CONTRACTORS GNATURE PERMIT OFFI PERMIT XPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO LL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER � �iii�i�i�iii�iiii iiiii iiiii iii�r i►iii iii►i iii►i tiiii iiii iiii . , , ; 2017168299 • , r�cpt:1904269 Rec: 10.00 - DS: 0.00 IT: 0.00 10/25/2017 K. K. , Dpty Clerk � - rRULR 5 0'NEIL,Ph D PRSCO CLERK 8 COh7PTROLLER - � - , 10/25/2017 02:00 m 1 of 1 _ _ '. OR BK ��2� PG ���'1 ' , Permit No � Parcel ID No 05-26-21-0070-00400-0020 NOTICE OF COMMENCEMENT � ', ' stace or . Florida , � co��ty of . Fasco , ', � THE UNDEFtSIGNED�hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, - the following information is Provided in this Notice of Commencement: 1 � Description of Property� Legal SILVERADO RANCH SUBDIVISION PHASES 2 3,8 4 PB 73 PG 59 BLOCK 04 LOT 02_. _ - st�eetAdd�es5. 6477 Paden Wheel Street , zepnryn�ns FL 3s5a� � , � 2. General Description of Improvement Single Family Residerice/Pool/Screen Enclosure/Fence - - . 3. �, Owner Information: Lennar'Homes, LLC ' � Name , - ,' 4600 W Cypress.St Ste 200 Tampa . FL.33607. , , �. Address' - � ' City State I � , � Interest in Property � - , " � ' Nartie of Fee Simple Titleholder N�A . ' - � (If.other.than owner) - � Address ' City State � " a ' Contractor Lennar Homes LLC ' � Name - 460.0 VV Cypress St, Ste 200 Tampa , FL, 33607 Add�ess City State Contractor's Telephone_No.. $13.574.5700 _ . 5. Surety ".` `:�. N/A , - Name Address Gity State _ ` Amount of Bond: $ Telephone No.. 6. Lender: N/A Name , { • Address City State Lender's Telephone No.. � , 7 Persons within the State of. Florida designated by the owner upon whom notices or other documents may be served as provided by I Section 713.13(1)(a)(7),Florida Statutes: 'I _ � Lennar Homes LLC � Name , � ' 4600 W Cvpress St. Ste 200 Tampa FL, 33607 • Address City State � � Telephone Number of Designated Person: 813.574.5700 - 8_ In addition to himself,the owner designates N/A of � to receive a copy of the Lienor's.Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Numtier of Person or Entity Designated by Owner ' _9. F�cpiration date of Notice of Commencement is dne year from the date of recording unless a different date is specified: " - , WARNING TO OWNER. ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENl` ARE'�CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, FART 1, SECTION 713 13, FLORIDA STATUTES, AND CAN • RESULT IN YOUR ,PAYING TWICE FOR IMPROVEMENTS TO YOUR.PROPERTY A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SIl'E BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING;CONSULT � WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. I STATE OF FLORIDA �� � ' COUNTY OF PINELLAS , � Signature of Owner or Owner's Authorized O�cer/Director/PartnerlManager , � � Vice President � Signatory's Title/Office ` ` , .:The foregoing instrument was acknowledged before me this �2 day of Ma[ch ao1.� ,by Steve Robert Smith ' as Vice President _ (type of officer,trustee,attorney in fact)for � Lennar Homes.'LLC � ` ���name pariy on be �hom instrument was executed): . .Personally Known�OR Produced Identification❑ ; otary Signature _ . • �Type of Identification Produced . � e Print) EI' sa Holleran � � ,Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in , i - - , it are true to the best of my knowledge and belief. . �����' ELISSAM.HOLI.ERAN Signature of Natural Person Signing Above � � � � � _�i�'�,.*,.C�mmUalbn#FF 88583I � �' Ex�lree Jun e 6,2020 wpdata/bcs/bcs form:. �`r���''�� 6undo1Thru7�oy,FolNMu�ncel00ai5-7010 � � �. �dD�u�y��. �-�' a � ��'> STATE OF FLOt�89�A, �pU�TY OF Pr�SCO . .� ::r� � � • �;� �?.�=`' �`� THIS IS TO C�RTIFY THAT THE FORcG01NG IS A �"�Y•,;�:`,� TRUE AND CORRECT COPY OF THE DOCUMENT � e ' ��� � a`�`� ON FILE OR 0�PUBLIC RECORD IN THIS OFFICE � o t�tGod�,e.• "-*��' .� "'� W�Tf�,ESS MY HAND AND OFFI L SEAL Tki� � , �ra�-r �' � ��� DAY QF ' PAULA S. O'NEIL, CLE K& COfUiPTR (�� �► � �88 O. . � OLLE .a'�1y� � o �,' � g ��������� DEPUTY CLE�K ` ' : PASCC} COUNTY, �LORtDA . ' Permit Na. ����Z" Date PermStted -�v-j� Builder NamelOwner Name �c„�►' !"����' Cantroi# Gounry Parcel No, ,Q�"��'��^d07p�Q�UP���f.7 SubDiv: C�+����a — AddresslLocation ���� �����'' (�t.!1�-��(,`�� Ciassificattontfype of Use iYY(� �&�,�i�r CG1 � T TRANSPL?RTATION IMPACi'FEE � Rate: Sq.Ft Unit: � Exempt []Yes ❑ No How Determined � lmpact Fee Amount �_ 3�63� � Zone No. TAZ: SCHOOL IMPAG7 FEE Accou�t (656) Single-Family Detached House Amount $ l�,�7�p• Z� (057} Mabite Home (058) Other Residentiai 123) Coltectlon Fee Exempt (�Yes [� No How Determfned PARKS AhtD RECREATIGIN FEE Land Account Land Credit Land 7ota! Recreation Accaunt Recreation Credit Recreation Tota! Zone TOTAI.AMOUNT $ '7�•r f: c�� Exempt [�Yes (� No How DetermIne@ LIBRARY FEE �and Account Land Credit Land Totai Facility Accaunt Faciliiy Cred(t Facility Total Exempt ❑Yes ❑ Na How Determined Tota{Amount -�a��� RESOURCE FEE ERU TOTA�AMOUN'i' � Prepared By Checked By NO CERTIFICATE OF OGCUPANCY WILL BE tSSUED OR FtNAL(NSPECTfON PERFORMED UNT1L THE 1"OTAL AMOUNTS LlSTED HAVE BEEN PAiD AND RECEIP7ED FOR BY p►CENTRAL PERMtTTlNG OFFICE C1F PASCO COUNTY Acknowlsdgement below doea not impty ecceptance of concurcence,but slmp{y raceipt of a copy of tfiis form,placing tl�e�uAding permit owner on notice of this assessmant and thQ conditlons oF payment for same. DATE RECEiVEQ BY RECE[PT NQ. DATE BY OS-26-21-0070-00400-0020 � Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Monday, October 23, 2017 Parcel ID 05-26-21-0070-00400-0020 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $27,062 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 6477 PADEN WHEEL ST ZEPHYRHILLS, FL 33541 Just Value $27,062 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $27,062 SILVERADO RANCH SUBDIVISION PHASES 2, 3 &4 PB 73 PG 059 $27,062 BLOCK 4 Taxable Value LOT 2 Jurisdiction City of Ze�hvrhills Land Detail (Card: 001 of 001) Line _ Use Description;Zo ing Units Type Price Condition Value _ 1 0100 SFR MPUD 6,000.00 SF $4.40 � 1.00 $26,400 2 � 0100 SFR —� MPUD 2,007.00 SF $0.33 j 1.00 � $662 Additional Land Information Acres i 0.18 iTax Area 30SI I FEMA Res�dential Code SLVRCPI Code�� . Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved I ` Extra Features (Card: 001 of 001) _ Line _�escription ____ �Year Units Value No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page !� Type DOR Code Condition �mount 10/2017 9620 / 2310 Warranty Deed 05 � Vacant Multi-Parcel Sale 09/2011 _ 8606 / 3376 _ _ Warranty Deed 05 _ Vacant i Multi-Parcel Sale � 05/2010 i 8373 / 1912 � Certificate of Title � 12 Vacant � $0 http://search.pascopa.com/parcel.aspx?parce1=2126050070004000020 10/25/2017 � � �s-aso-oozo � City of Zephyrhills Permit Application Fax-813-780-0021 Building Department . Date Received Phone Contact for Permittin 813 363 __ 2891 Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700 Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name N�A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 6477 Paden Wheel Street LOT# 0020 SUBDIVISION Silverado Ranch Subdivision Ph 2,3,&4 pARCEL ID# 05-26-21-0070-00400-0020 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED II�/ II NEW CONSTR e ADD/ALT 0 SIGN � 0 DEMOLISH � INSTALL REPAIR PROPOSED USE � SFR Q COMM � OTHER TYPE OFCONSTRUCTION � BLOCK � FRAME � STEEL � DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF 3038 SQ FOOTAGE 2277 HEIGHT 1 Story T�TTr T�TTI"'f'T"TTrI"1"T�TITr1TT1TrIT9TTITTRT1Tr1"' ✓ BUILDING $ G O VALUATION OF TOTAL CONSTRUCTION O '�/ 'ELECTRICAL $ � PROGRESS ENERGY � W.R.E.C. ' � ` � AMP SERVICE �PLUMBING $ � / (/� �g�� �.U ��/ �MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION , . � , �GAS � ROOFING � SPECIALTY � OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA �YES �O u -�-��--�4-�--�-�--��F-F-F-�-�E-�--�-�--�.�--�-�4-+--�-F-�-�--�-�E-�--�-�-�--�-��--�-�F-�--F-�--�-F-�--�-�-+--�-F-�-�--�-�-F-�--F-�--�F-�-F� BUILDER COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4600 W.Cypr ss St.Ste.200,Tampa,FL 33607 License# CGC1518166 ELECTRICIAN COMPANY Edmonson Electric, �f1C. ' SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 1034 Skipper Road, Tampa, FL 33613 License# EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P•O. Box 5308 Bayonet, FL 34674-5308 �icense# CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE � REGISTERED Y/ N FEE CURREN Y/N Address P O. Box 5308, Bayonet, FL 34674-5308 License# CAC058062 OTHER COMPANY SIGNATURE � REGISTERED Y/ N FEE CURREN Y/N Address 4211 Shoal Lin Blvd, Spring Hill, FL 34607 �icense# CCC057991 � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � t � � � � � � � � � � � � � � � � � RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Eiuilding Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. **"`PROPERTY SURVEY required for all NEW construction. -�'--'•-C--'.1..�1-�1-i-f�l-1--1�..4��{�1-'• '�' :--:.���.1--1-i�1--��1..4.1..1..��4-1-.����I..��L..1..{�1..��1���..1..4.S�L�'.--C..p-� Directions: Fill out application completely Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) "" Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(PIoUSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF QEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictians" which may be more restrictive than Caunty regulations. The undersigned assumes responsibility for compliance with any applicable deed restricfions. UNLICENSED CONTRACTORS AND COtdTRACTOR RESPONSBILITIES: If the owner has hired a contractar or cantraetors to undertake tnrark, they may be required ta be licensed in 2iccordance with state and foca{ regufatians. if the� , contracfor is not lieensed as required by law, both the owner and contractor may be cited for a misdemeanar violation under state law. If the owner or intended cantractar are uncertain as to what licensing requirements may apply for the intencied work, they are advised ta contact the Pasco Caunty Building Inspection Division—Licensing Sectian at 727-847- 8009. Furthermore, if the owner has hired a can#ractor or cantractors, he is advised to have the contractor(s) sign portions of the "contractar Block" of this application for which they wil! be responsible. if you, as the owner sign as the contracfor, that may be an indicafion that he is not properly (icensed and is not entit(ed to permitting privi(eges in Pasco County TRANSPORTATION tNIPACTJUTILIl'IES IMPACT AND RESOURCE RECOVERY FEES. The undersigned urtderstands that Transpartation Impact Fees and Recourse Recavery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County (�rdinance number 89-07 and 90-07, as amended. The undersigned a(so understands, that such fees, as may be due, will be identified at fhe time af ' permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid priar to recsiving a "csrtificate of accupancy" or final power release. If the praject does not invalve a certificate of occupancy ar final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior ta permit issuance in accordance with applicable Pasco County ordinances. CONS7RUCTION �1EN LAW(Chapter 7�13, Florida Statutes, as amended). If valuation of wark is$2,500 00 or more, I certify that I, the applicant, have been pravided with a copy of the "Florida Construction Lien Law—Hameowner's Protection Guide" preparad by the Florida Department of Agricu(ture and Consumer A�fairs if the applicant is sameone other than the"owner", I certify fhat I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTUR'S/QWNER'S AFFIDAV[T 1 certify that all the informa#ion in this applicafian is accurafe and that aEl work will be done in compliance with all applicable laws regulating canstruction, zaning and land development. Application is hereby made ta obtain a psrmit to do work and instal{ation as indicated. 1 certi#}r that na wark or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating , , construction, County and City codes, zoning regulations, and land development regulatians in the jurisdiction. I also certify that 1 understand that fhe regulatians of ofher gavernment agencies may apply to the in#ended work, and that it is . my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to � - Department af Enviranmental Protection-Cypress Bayheads, Wetland Areas and Epviranmentally Sensitive �, Lands,Water/UVastewafer Treafinent. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps af Engineers-Seawalls, Docks, Navigable Waterways. - Department af Health & Rehabilitative Services/Environmental Nealth Unit-We!!s, Wastewater 7reatment, Septic 7anks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Autharity-Runways. I understand that the follawing restrictians apply to#he use of fill. - Use of fill is not allowed in Flood Zone"V"unless expressly permitted - If the fill materiai is to be used in Flood Zone "A", if is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a prafessional engineer licensed by the S#a#e of Florida. - If the fill material is to be used in Flaod Zone "A" in connection with a permitted building using stem wall construction, I certify that fi{I will be used only to fi!!the area within the stem wall. - If fil( maferial is ta be used in any area, I certify that use af such fi(I wil( not adverseiy affect adjacent properties. If use af fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditians af the builciing permit issued under the attached permit applicatian, for lofs less than one {1} acre which are elevated by fill, an engineered drainage plan is required. If( am the AGENT FQR THE OWNER, ! promise in good faiCh to inform the owner of the permitting conditions set forth in tfiis affidavit prior fo commencing constructian. I understand thaf a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installatians nat specifically included in the application A permit issued shall be construed ta be a license to proceed with the wark and not as authority to vialate, cancel, alter, ar set aside any provisions af the technical codes, nor shall issuance of a permit prevent the Building Official from fhereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall became invalid unless the work authorized by such permit is commenced within six manfhs of permit issuance, ar if wark authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be regues#ed, in writing, from the Building Official for a periad nat ta exceed ninety {90} days and will demonstrate justifiable cause for the extension. If work ceases for nineky(90) consecutive days, the job is considered abandoned. � WARN[NG TO OWNER: YOUR FAtLllRE TO RECORD A NOTIGE UF CUN[M�NCEMENT MAY RESUL,T tN YC}UR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WI7H YOUR LENDER OR AN ATT4RNEY BEFORE RECORDING YQUR NQTICE QF CO ENCEMENT. FLORIDA JURAT(F.S.117.03) _ � OWNEE2 OR AGENT CONTRAGTOR Subscribed and sworn to(or a� ed)before me fhis Subscribed and swarn to(or affirmed} fare me this ��-�'�p-�� py paul Swee �z-se,-„- -- -qy paul Sweene Wha islare ersonall known o me ar Who islare personally known to me or-Hasl�eve-�re�ee� as idantification. �� as identificafion, � �,�/"""�y Notary Public 4�-�"�""`-----�_� Notary Public Gommissian No. F�g�537 ommission No. FF98537 Elissa M.kiolleran Elissa M.Holleran Name of NofarV tvDed,printed or sfamped Name of Notary typed,printed ar stamped �...�.�.,��..�.�,�, �"h� ����hN.Pl�I��N .'''• 1, �tl��l,�f,�1�t��� � � C�rrm"a�!an��.tl��l�q�� � g Gntstt����n;�FP�t�47 �l►40;��►;a�d,�t�� � r�F�(►4'#:�,tut�t�'��'�� � �,.��:�`��i�rd�tr�E:��is��nx�14�F���UMi ' Pd;, . �i�►i�`ira'°^r�f�'alais��#tt�1��]l9�Tki1 ; , , Lennar Homes-6477 Paden Wheel St-3,038 sq ft o umn SQ. FEET PRICE MAIN OR LIVING: � 3,038 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 342,230.70 FEE SHEET $ 1,217.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,321.34 ELECTRICAL: $ 273.83 PLUMBING: $ 182.55 MECHANICAL: $ 127.79 SUB-TOTAL $ 1,905.50 TOTAL $ 1,905.50 S EW ER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL �r(�,?,/ TOTAL: $ _ t j J 1 PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,458.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 \ TOTAL: $ 11,736.69 a � � � :� .r1�WAlUA ��� n4f:3+.�� _,�; - �;s�,��v - 't II� '� City of Zephyrhills BUILDING PLAN REVIEW CONIMENTS Contractor/Homeowner: �(/1.(/1Q-r-- �7vi,p Date Received: �-c3(�-- � 7 Site: l0 � [ � ��z/'1 W��� � ` Permit Type: �� �� �'4 � 2 z�7 ,�-� Approved w/no comments:❑ Approved w/the below comments: � Denied w/the below comments: ❑ 6��� S�� This comment sheet shall be kept with the permit and/or plans. ��-r�, --�- Kalvin Switzer lans Examiner Date Contracto and/or Homeowner �, (Requir d when comments are present) �, PASCO COUNTY �.,,:;���� DEVELOPMENT SERViCES P ,`?a� 8731 Citizens Drive Date:2/22/2018 COUNTY FLORID��� New Port Richey,FL 34654 pe�v 5rncr•s.[4tuur.r Nt+�cis. 727-847-2411 �* �oTA ���Mi�r *� Receipt#: 1739637 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIP7# bATE Impact Fee Residential Solid 24503100-329010 54.74 1321799 $273.70 $273.70 1739637 2/22/18 Waste Single Fa�nily TOTALS: $273.70 $273.70 Receipt# Paid Bv Check# CC Auth# Cashier ID Workstation Receiut Date Amt Paid 1739637 Check 00958013 540 BCCCP06W 02122l2018 $273.70 Total Payments: $273.70 Pa or Address Phone Lennar Homes LLC 4600 W Cypress Street Suite 200 7ampa FI 33607 Comments: � City of Zephyrhills � �j � Z . b Z' Perm(t 18982, �� � � � 6477 Paden Wheel St. �o-� Permit 19001, 6620 Paden Wheel St. 3 0� Permit 19138, 6601 Silverado Ranch Blvd. o b Permit 19247, 3 6646 Paden Wheel St. Permit 1925D, 3 p� 6623 Silverado Ranch Blvd. While you wlll be payfng yout bill wlth Pasco County DevelopmentServices,the full amount of the tredlt ta�d or e-theck fees,NOT shown above,Is collected by Flrst ellling payment sarvicas. MyReports/reports//PRODUCTION/PASCOlReceiptPOS V5.rpt 2/22/2018 Page 1 of 1 II • • 6477 Paden Wheel St o umn SQ. FEET PRICE UNDER ROOF: 3,038 $ 112.65 OTHER: - $ - VALUATION $ 342,230.70 FEE SHEET $ 1,217.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,321.34 ELECTRICAL: $ 273.83 PLUMBING: $ 182.55 MECHANICAL: $ 127.79 SUB-TOTAL $ 1,905.50 TOTAL $ 1,905.50 SEWER: WATER: IRRIGATION: $ - TOTAL: $ . WATER METER: IRRIGATION METER FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,458.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,736.69 Single Family Dwelling Plan Review Comntlents 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. - 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. 9. No electric, plumbing, mechanical, or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. A112008 N.E.C. Codes will be enforced. 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 22. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 5�'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008) [. � ^ " � � x FORM R405-2014 " : . FLORIDA ENERGY EFFtCIENGY CODE FOR BUILDiNG C�NSTRUCTION Florida Department of Business ar�d Professional Regulation - Rasidential Performance Method Project Name: 2268A sf ADS Builder Name: LENNAR HdMES 04{�2 street: 6477 Paden Wheel Street Permit Office: �i af Zephyrhills City,State,Zip: ,Fl., Permit Numher• ����?j Ownec LENNAR HOMES Jurisdiction: (1 6t5 Design Locatian: FL,7ampa County:: Pasco{F(orida Climate Zone 2) 1. New canstruction or existing New(From Plans) 9. Wall Types(2268.0 sqft.) Insulation Area 2. Single famity or multiple famiIy Singte-family �.�ancrefe Block-!nt Insul,Exterior R=4.1 1904.00 ftz b.Frame-Wood,Adjacent R=11.0 364.00 fkx 3. Number of units,if multiple family 1 c.N/A R= frx 4. Number af Bedraoms 4 d.NIA R_ {�2 10.Ceiling Types (2267.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2267.00 ft' 8. Gonditioned floor area above grade(ff2} 2267 b.NJA R= ft2 Conditioned floor area Uelow grade(ftz) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows{277.0 sqft.) Description Area a.Sup:Attic,Ret:iVfain,AH:Ntain 8 453 a. U-Factor: Dbl, U=0.54 143.00 ft2 SNGG: SHGC=Q.31 b. U-Factor Dbl,U=0.58 96.d0 ftz 12•Cooling systems k8tu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 a U-Factor. Dbi,U=0.56 38A0 ff2 SHGC: SHGG=0.2$ 13.Heating systems kBtu/hr Efficiency d. U-fiactor: N!A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: A.206 ft. Area Weighted Average SFiGC: p.gp9 14.Hot water systems 8. Floor Types (2267.0 sqft.) Insulation Area a.Etectric Cap:46 galions EF•0.950 a.Slab-On-Grade Edge lnsulation R=O.Q 2267 00 ft2 h. Conservation features b.td/A R= ft2 Nane c.N/A R= ftx 15.Credits Pstat Glass/Floor Area: 0,122 Tatal Proposed Modified Loads: 75.57 pASS Tatal Base(ine Laads_ 76.12 1 hereby certi€y that the plans and spec"sfications covered by Review of the plans and d�Tk���T��,� �- this calculation are in compliance with the Florida Energy specificatians cavered by this �,�' ,��, "'"_.��i O�,_' Code. calculation indicates compliance ��'r„ '' `==,`C�� Ys+. /, with the Fiorida Energy Code. �rr�,s�. �,.4.'t,ti� v F.. x �%;; ::�.�`'��;�. � PREPARED BY: �a e ����v` Before constructian is campleted � - �•, 'r�� " � � DATE. this building wil[be inspected for � �r,���". : �,,. : compliance with Section 553.908 ' *. =�.��'� .' .�. (hereb certi that this buildin as desi ned,is in com liance Florida Statutes. ,r+ .. -: +�: Y fY 9, 9 P '�?�, _. ��- E with fhe Florida Energy Code. " OD'�yEfi�' OWNEFilAGENT: BUILDING O F1ClAL: DATE: � DATE: �`' - Compiiance requires certifica�ion y the air handler unit manufacturer that the air handler enclosure qualif[es as certified factary-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and tnsulation Inspection Checktist in accordance with R402.4.1.1 and an envelape leakage test reporE in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to autdoors, testecf in accarclance with Secfion 803 af RESNET Standards,is not greater than OA60 Qn for who[e house. 8/11/2017 12:29 PM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant 8oftware Page 1 of 4 ( ( ' FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2268A sf ADS Build�r Name: LENNAR HOMES O402 street: 6477 Paden Wheel Street Perr„�c o�r.�: City of Zephyrhills City,State,Zip: ,FL, Permit Number Owner. LENNAR HOMES Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2268.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1904.00 ftz b.Frame-Wood,Adjacent R=11.0 364.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 4 d•N�'4 R= ftZ 10.Ceiling Types (2267.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2267:00 ftZ 6. Conditioned floor area above grade(ftz) 2267 b.N/A R= ft2 z Conditioned floor area below grade(ft2) 0 c. A R= ft 11.Ducts R ft2 7. Windows(277.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 453 a. U-Factor Dbl,U=0.54 143.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl, U=0.58 96.00 ftZ 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 c. U-Factor: Dbl,U=0.56 38.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor� N/A ftZ a.Electric Heat Pump 32.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 4.206 ft. Area Weighted Average SHGC: 0.309 14.Hot water systems a.Electric Cap:40 gallons 8. FloorTypes (2267.0 sqft.) Insulation Area EF 0.950 a.Slab-On-Grade Edge Insulation R=0.0 2267.00 ftz b. Conservation features b.N/A R= ftz None c.N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 75.57 pASS Glass/Floor Area: 0.122 Total Baseline Loads: 76.12 I hereby certify that the plans and specifications covered by Review of the plans and �'fN�STA�,� •,. O '_'-r��> > this calculation are in compliance with the Florida Energy specifications covered by this ' y- _� O �i,; :=p:. ..�t�. '' Code. calculation indicates compliance . .;�'�"�;,� � _ �.•� ,�s+. . �ave ���G� with the Florida Energy Code. ��+ ��rrf.�'%:":;•_::�':;;•�'��ti,�O ` PREPARED BY' Before construction is completed r i '"' ;� � DATE: this building will be inspected for � -`1�1��---- - �° .� �u I .� compliance with Section 553.908 *. - �� I hereby certify that this building,as designed, is in compliance Florida Statutes. .� - = ` ,S with the Florida Energy Code. G'OZj' ����. � W�. OWNER/AGENT: BUILDING OFFICIAL� DATE. DATE: � - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.060 Qn for whole house. 8/11/2017 12:29 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 ( 1 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential PerFormance Method Project Name: 2268A sf ADS Builder Name: LENNAR HOMES O402 street: 6477 Paden Wheel Street Permit�ce: City of Zephyrhills City,State,Zip: ,FL, Permit Number• Owner LENNAR HOMES Jurisdiction: 611600 Design Location: FL,Tampa County�• Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2268.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1904.00 ft2 b.Frame-Wood,Adjacent R=11.0 364.00 ftz 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ftZ 10.Ceiling Types (2267.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2267.00 ftZ 6. Conditioned floor area above grade(ftZ) 2267 b.N/A R= ftZ z Conditioned floor area below grade(ft2) 0 11 Ducts R R ffz 7. Windows(277.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 453 a. U-Factor: Dbl,U=0.54 143.00 ftZ SHGC: SHGC=0.31 b. U-Factor• Dbl, U=0.58 96.00 ft2 �2•Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 c. U-Factor Dbl,U=0.56 38.00 ftz SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor• N/A ftZ a.Electric Heat Pump 32.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 4.206 ft. Area Weighted Average SHGC: 0.309 14.Hot water systems a.Electric Cap:40 gallons 8. FloorTypes (2267.0 sqft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 2267.00 ftz b. Conservation features b.N/A R= ftZ None c.N/A R= ftZ 15.Credits Pstat Total Proposed Modified Loads: 75.57 pASS Glass/Floor Area: 0.122 Total Baseline Loads: 76.12 I hereby certify that the plans and specifications covered by Review of the plans and . �.�Zk1E,ST�T� .., this calculation are in compliance with the Florida Energy specifications covered by this ��y ' "_ �. p Code. calculation indicates compliance � �'��;,��s ,`=?`�4�.�.K+. . ,{ with the Florida Energy Code. ti�+urr�.'?. -.;;:=',�.•,•���s �O' PREPARED BY: _ �aVe tf���� Before construction is completed i� •, " "``�`� �� DATE. this buildin will be ins ected for �' � ��"- �-- " � Q 9 P � ��;;�(� �. . compliance with Section 553.908 *, .�.�..- ,. ..* I hereby certify that this building,as designed, is in compliance Florida Statutes. ,� , - ;�_. with the Florida Energy Code. G'OZy��� ' OWNER/AGENT: BUILDING OFFICIAL: DATE. DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enc osure qualifies as certifed factory�ealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house. 8/11/2017 12:29 PM EnergyGaugeC�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 (' i FORM R405-2014 PROJECT Title: 2268A sf ADS Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2267 Lot# Owner. LENNAR HOMES Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: LENNAR HOMES Rotate Angle: 0 Street: Permit_Office: Cross Ventilation: No County: Pasco Jurisdiction: Whole House Fan: No City,State,Zip: Family Type: Single-family , FL, New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp �� Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Block1 2267 21083.1 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 Main 2267 21083.1 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 242 ft 0 2267 ftZ � 0.3 0 0.7 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2535 ftZ 0 ft2 Medium 0.85 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2267 ft2 N N CEILING # Ceiling Type Space R-Value " Ins Type Area Framing Frac Truss Type 1 UnderAttic(Vented) Main 30 Blown 2267 ft� 0.1 Wood 8/11/2017 12:29 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 P � FORM R405-2014 WALLS - Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block-Int Insul Main 4.1 12 8 9 4 118.2 ftZ 0 0 0.6 0 2 S Exterior Concrete Block-Int Insul Main 4 1 31 4 9 4 292.4 ft2 0 0 0.6 0 3 E Exterior Concrete Block-Int Insul Main 4.1 64 0 9 4 597.3 ftZ 0 0 0.6 0 4 W Exterior Concrete Block-Int Insul Main 4.1 75 � 9 4 700.0 ft� 0 0.6 0 _ 5 N Garage Frame-Wood Main 11 28 0 9 4 261.3 ft� 0.23 0.01 0 _6 E Garage Frame-Wood Main 11 11 0 9 4 102.7 ftZ 0.23 0.01 0 7 N Exterior Concrete Block-Int Insul Main 4.0999 4 8 11 4 52.9 ft' 0 0.600000 0 8 S Exterior Concrete Block-Int Insul Main 4.0999 15 4 9 4 143.1 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Main None .2 3 6 8 20 ftZ 2 N Wood Main None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => chan ed to Worst Case. / Wail Overhang �� # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 7 Metal Low-E Double Yes 0.56 0.28 6.0 ft2 5 ft 0 in 0 ft 8 in None None 2 N 1 Metal Low-E Double Yes 0.56 0.28 32.0 ftz 1 ft 0 in 3 ft 0 in Drapeslblinds Exterior 5 3 S 2 Metal Low-E Double Yes 0.54 0.31 48.0 ftZ 1 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 4 S 8 Metal Low-E Double Yes 0.58 0.32 96.0 ft2 10 ft 0 in 0 ft 2 in Drapes/blinds Exterior 5 5 E 3 Metal Low-E Double Yes 0.54 0.31 23.0 ft2 1 ft 0 in 0 ft 8 in None None' 6 E 3 Metal Low-E Double Yes 0.54 0.31 12.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 � 7 W 4 Metal Low-E Double Yes 0.54 0.31 48.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 8 W 4 Metal, Low-E Double Yes 0.54 0.31 12.0 ftz 1 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation i 1 595 ftZ 595 ft2 60.2 ft 9.3 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000414 2459.7 135.03 253.95 .3102 7 S/11/2017 12:29 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 3 of 4 i , � FORM R405-2014 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF.8.5 32.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:15 34.2 kBtu/hr 1026 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS � —Supply— —Retum— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 453 ft2 Main 113 ftZ Proposed Qn Main —cfm 136.0 cfm 0.06 0.60 1 1 ; TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb Mar A r Ma X Jun X Jul Au Se Oct Nov Dec Heating Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Venting Jan Feb X Mar Apr May Jun Jul Aug Sep Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 1 -Electric Heat Pump 0°/a 1 -Central Unit 8/11/2017 12:29 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 T � FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerFormance Index, the more efficient the home. „ FL, 1 New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1904.00 ft2 b.Frame-Wood,Adjacent R=11.0 364.00 ft 3. Number of units,if multiple family 1 c.N/A R= ftZ 4. Number of Bedrooms 4 d.N/A R= ftZ 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area 2 a.Under Attic(Vented) R=30.0 2267.00 ft 6. Conditioned floor area(ftZ) 2267 b.N/A R= ftZ 7. Windows�' Description Area c.N/A R= ft2 a. U-Factor Dbl,U=0.54 143.00 ftZ 1�•Ducts R ftZ a.Sup:Attic,Ret:Main,AH:Main 6 453 SHGC: SHGC=0.31 b. U-Factor Dbl, U=0.58 96.00 ftZ SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency c. U-Factor� Dbl,U=0.56 38.00 ftZ a.Central Unit 34.2 SEER:15.00 SHGC: SHGC=0.28 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 32.8 HSPF:8.50 Area Weighted Average Overhang Depth: 4.206 ft. Area Weighted Average SHGC: 0.309 8. Floor Types , Insulation Area 14.Hot water systems : a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 2267.00 ft EF•0.95 b.N/A R= ftZ c.N/A R= {{2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building ��I�SrA Construction through the above energy saving features which will be installed (or exceeded) �.a. � - _ ?�o. in this home before final inspection. Otherwise, a new EPL Display Card will be completed �`;,`''�. �='�,.�:�',�,�. c�. ., -'=.�. based on installed Code compliant feature . � r;l„'�c.�.,;;::�=�:.•°:':�°„ro ;W .,,, � v' ,. ;..r Builder Signature: � Date: 08/15/17 � Y�?j��(��,�� . � .* �. Address of New Home: 6477 Pa en Wheel Street Ciry/FL Zip: Ze�hyrhills,FL 33541 ..�'Co��� v�'� , D�N►E,'T� - , *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/11/2017 12:30 PM EnergyGaugeOO USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 . Buildin Anal $�$ Job: 2268A sf ADS g y Date: 8I1112017 Entire House By: Dave Bayonet Plumbing Heating and Cooling 8950 New York Ave,Hudson � � ' 0 � For: Lennar Homes � - • • • � Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 . Component Btuh/ftZ Btuh % of load Walls 5.6 9246 27.6 �as GlaZing 21.8 6006 17.9 wa�� nfiltration Doors 23.5 466 1.4 Ceilings 1.3 2844 8.5 Floors 3.6 8064 24.1 Infiltration 1.7 3359 10.0 D ucts 3493 10.4 Plplllg 0 0 F�oors Humidification 0 0 Glazing Ventilation 0 0 o�e� Ceilings Adjustments 0 Total 33476 100.0 • • • Component Btuh/ftZ Btuh % of load Walls 2.8' 4599 16.0 Wa�� Intemal Gains ' Glazing 41.5 11424 39.8 Doors 18.4 365 1.3 Ceilings 1 J 3927 13.7 �ucts Floors 0 0 0 Infiltration 0.4 698 2.4 i D ucts 3927 13.7 - ' Ventilation O O Infiltration Internal gains 3750 13.1 BIOwBf 0 0 Glazing Ceilings Adjustments O Other ' Total 28689 100.0 Latent Cooling Load=3170 Btuh Overall U-value= 0.105 Btuh/ft2-°F Data entries checked. ,� wri htsoft� 2017-Aug-1112:26:51 �� g Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 ...th CBA27UHE AH's\2268A sf ADS template 3ton.rup Calc=MJS Front Door faces: N Pro ect Summa Job: 2268A sf ADS � � Date: 811112017 Entire House By: Dave Bayonet Plumbing Heating and Cooling 8950 New York Ave,Hudsan � � ' • � For: Lennar Homes N otes: � - � • � Weather� Tampa InternationalAP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 39 °F Design TD 16 °F Daily range L Relative humidity 50 °/a Moisture difference 55 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 29983 Btuh Structure 24763 Btuh Ducts 3493 Btuh Ducts 3927 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 33476 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 28689 Btuh Method simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2449 Btuh Ducts 721 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ftz 2267 2267 Equipment latent load 3170 Btuh Volume��t3) 21250 21250 Air changes/hour 0.22 0.11 Equipment Total Load (Sen+Lat) 31859 Btuh Equiv.AVF(cfm) 78 39 Req. total capacity at 0.85 SHR 2.8 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-036-230-21 Cond 14HPX-036-230-21 AHRI ref 10258598 Coil CBA27UHE-036-230'`++TDR AHRI ref 10258598 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 29580 Btuh Heating output 32800 Btuh @ 47°F Latent cooling 5220 Btuh Temperature rise 25 °F Total cooling 34800 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.90 Capacity balance point= 33°F Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. „ wri htsoft' 2on-n�9-���2:2s:s� �� g Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 ...th CBA27UHE AH's12268Asf ADS template 3ton.rup Calc=MJB Front Door faces: N Manual S Compliance Report Job: 2268A sf ADS Date: 8/1112017 , Entire House By: Dave � Bayonet Plumbing Heating and Cooling 8950 New York Ave,Hudson � � ' • � For� Lennar Homes • • • • . Design Conditions Outdoor design DB: 91.3°F Sensible gain: 28689 Btuh Entering coil DB: 75.6°F Outdoor design WB: 77.3°F Latent gain: 3170 Btuh Entering coil WB. 62.8°F Indoor design DB: 75.0°F Total gain: 31859 Btuh Indoor RH: 50% Estimated airflow� 1200 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SpIitASHP Manufacturer: Lennox Model. 14HPX-036-230-21+CBA27UHE-036-230*++TDR Actual airflow: 1200 cfm Sensible capacity: 29070 Btuh 101% of load ' Latent capacity: 5130 Btuh 162% of load 0 0 Total capacity: 34200 Btuh 107/o of load SHR: 85/o • � • Design Conditions Outdoor design DB: 30.8°F Heat loss 33476 Btuh Entering coil DB� 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Lennox Model. 14HPX-036-230-21+CBA27UHE-036-230*++TDR Actual airflow� 1200 cfm Output capacity: 32800 Btuh 98% of load Capacity balance: 33 °F Supplemental heat required: 676 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer n/a Model: n/a+n/a Actual airflow: 1200 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 °F Meets are all requirements of ACCA Manual S ,� wri htsoft' 2017-Aug-1112:26:51 9 Right-SuiteQtl Universal 2017 17.0.23 RSU05714 Page 1 �'� ...th CBA27UHE AH's\2268A sf ADS template 3ton.rup Calc=MJ8 Front Door faces: N \ ,\ PLOT PLA�I NOT ASBOUND RYLSURVEY SEC. 04,05 , TWP. 26 S, RNG. 21 E. LOT 2, BLOCK 4 BEARING BASIS: SILVERADO RANCH SUBDIVISION NORTF{ BOUNDARY OF SE� OF 05-26-21 BEING N 89'25'01" E PHASES Z, 3 8C q- THIS SURVEY IS SUBJECT TO ANY FACTS THAT PASCO COUNTY, FLORIDA. � MAY BE DISCLOSED BY A FULL AND ACCURATE TITLE SEARCH. ALSO SUBJECT TO SETBACKS, PRELIMINARY DRAWING' EASEMENTS AND RESTRICTIONS OF RECORD. 'f}iIS PLAN IS FOR PERMITTING PURPOSES M UNDERGROUNO FOOTER, STEM WALL, AND ONLY, NOT FOR CONSTRUC110N. VERIFY p UNDERGROUND UTILITIES ARE NOT LOCATED OR ALL DIMENSIONS BEFORE ANY CONSTRUCTION. _ $HOWN. LEGEMD: J DO NOT SCALE THIS PRINT. DIMENSIONS AND .�-►= PROPOSED DRAINAGE FLOW Q NOTES TAKE PREFERENCE. (00.00) = PROPOSED GRADE � DESCRIPTION NOT CONTAINING PLAT BOOK AND E-00.00 = EXISTING GRADE � PAGE INDICATES THAT PLAT 15 IN - PRE�IMINARY STAGE AND IS SUBJECT TO NOTES: CHANGE AND/OR REVISION. LOT GRADING TYPE = B PROPOSED PAD ELEVATION = 109.4' CERTAIN DATA SHOWN HEREON BASED ON FRONT SEIHACK.= 20' or 22' ENGINEERING PLANS PROVIDED BY CLIENT. SIDE SETBACK = 7.5' STRUCTURE T1ES SHOWN HEREON DENOTES REAR SETBACK = 15' MEASUREMENT FROM FORM BOARDS/FOUNDATION TO PROPERTY LINE. EL S�REE / * = 10' UTILITY EASEMENT N �P�j �"� ' � P PpEN�WwR,Es� � ON LOT AREA CALCULATIONS � �r pCP(P)� �^ .: • � • �30' � LOT = 8007.93 SQ. FT. — . :..oo'o o:.'�'�?LH�$g, .;- ' LIVING AREA = 2267 SQ. FT. • ..3Q•,,�0 2 •;.:.'_ .% ENTRY = 23 SQ. FT. '" ��o^ ':��• GARAGE = 585 SQ. FT. :'',;�;'•~:� ;-•..;;;..,.-�: '•. COVERED LANAI = 153 SQ. 'FT. , ry PA110 = N/A SQ. F'T. .,.'.:�' o .��~��^ "- • � ' 832� CONC. DRIVE = 597 SQ. F7'. •..C�'�g�', . ` 1,Zr�.00.�' : A/C & CONC PAO = 9 SQ. FT. ' '�'.� ::"��; ' ;w� PRIVA7E SIDEWALK = 40 SQ. �f. . " . . . . '. . F�;. •;� IMPERVIOUS = 46 % — '' __.� %.1 �•s . - -�"��`.<,.. , = 3674_ o� 1 2 :N �-A�:': ':p:;� :. .:� SOD = 4333 —SQ. FT. �, �. . SQ. FT. L .�� o: �. ,..:26.00.�'::% '2$ 4 �'�;�.`"� 9� U� OFF LOT AREA CALCUI,.ATIONS � � RIGHT OF WAY 7109.56 $Q, �, � c3; DRIVE APRON 350 Sq. FT. g28' Q PUBLJC SIDEWALK = 312 gQ, � �- SOD = 448 SQ. FT. z . O LOT 1 � p�1: ' BLOCK 4 TOTALS � pPpSE� f''� AREA = 9117.49 SQ. FT. � pR •L2,6Spn DRIVEWAY = 947 _SQ. FT. � �V SIDEWALK = 352 SQ. FT. CP N� GpFtA�'E.��� `(�p89o� SOD = 478i SQ. FT. ' pa? �c p-� 2 4 � w� B40CK � i m. �O 1�, � O oi' BLOCK 4 ` j 46�88^e r, N 761 d� t1 5�� O � , � � 14.47 .QP/C rn: •�. �•, � •� /. a '-rn (lp� � �SO� �0,� w - M 50.93' �S �A°1983, o d� S ��.34'21 w 2� � _ . — . h ^ ^°� TRACT J � ` DRAINAGE AREA � m 3 U N ti ' PF�OPOSED: � Y CURVE RADIUS ARC CHORD BEARING DELTA LOWEST FLOOR ELEVATIONS: m C179 337.00" 37.75' 37.73' N 7732'03" E 06'25'07" LIVING AREA: 110.10� I V - �, DESCRI�I"IOI�d: GARAGE AREA: � LOT 2, BLOCK 4, MAP OR PLAT ENTITLED "SILVERADO RANCH SUBDIVISION PHASES 2, ELEVATIONS REFERENCED TO = NORTH AMERICAN VERTI'CAL � 3 & 4", AS RECORDED IN PIAT BOOK 73, PAGES 59 THROUGH 65, OF THE PUBLIC DATUM OF 1988. MEAN SEA � RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. � o APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL N0. 12101C 0288 F EFFECTIVE DATE: 9/26/14 � LEGEND: J (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, �= CENTERLINE, A/C= AIR CONDITIONER. B/C= BACK OF CURB, C/S= N CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, = F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, F(P= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED c.� PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT I Q REFERENCE MONUMENT, R/W.= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY EENCHMARK, � U P= U11LIN POLE, W F= WOOD FENCE R = RADIAL 1;��,;. 0 � JOHN R.BEACH&ASSOCIATES INC. Drawn By. Square Feetc__=. �0�7:93 f'--., ' SMS . � LENNAR HOMES � � SURVEYORS AND MAPPERS Checked By. ' � -- � - 911 WEST ST. PETERSBURG DRIVE JRB � y \� v� ONE OLDSMAR, FLORIDA 34677 -�� ' ' - �"'~� oWAY (813) 854-1276 FAX (813) 855-8370 Scale: �••_30' - � -� �' � •� NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 8 4 17 ACS � � f �. 'v THE ORIGINAL RAISED SEAL OF A FLORIDA ��- � � � � LICENSED SURVEYOR AND MAPPER � -P- BEA�hL-= •, - � DA7E rLORi REG LAND SURVEYiir2,Nv�2984 L8�{4493 % Revisions: REVISED PER GARAGE HAND 8/7/17 ACS - �,; �- � � _- i^, .�i/\ _i�� _ __ u- q j (�; ,r .'°," � , _ -. ,\ i � � 7 � th � 4• r- /e;l, , ,L�v ' - �1 � � �t -' -, \>� Dc t � � tn�. o'Yp� �F=�os.sa � � �O `�� s_s FF=109.90 FF=1Q9.70 � �� �_ < �� �°� � , -�- 1 LOT 12 - " �` •}��` ,� �-� LOT 2 � L0� 1 -;.� , 9 f 44�� J . I PAD-108.9 � � � . � O ,,p� 1 � Gj� p,_ PAD-109.0 .,,->� ! m � �� - U� � ��j� `� � .66 _ °�• '� O Uy-- � �g• �'1�� "� 7YPE A '.`� - � . • ` FF=1 1�T�0 - - � 0 , . � . r , tr �ie- i ��• �� 1 � "� 1 r ' :�-„y� � s- � ` �. - � � LOT 9 � �o m i s- �L.� �+ `" � ,s- r ��'� � PAD=f 09.6 � � ��� .- �,.' ° r ��' r � - ', j '; .��17�', � �\ TYPE A �� \� ` �• �� ,ir �r e- - �,.a ` � � � � � 110. � Y. \��. bs`� ii m• � FF=1Q9.5b �.�1i � � � • ' � \ r - �� 1 � � 9 6 ,c� � �' c - "Q� P�L0��1$g�jZ. ��F3- �� '�r1 i0� g �� y G��! � 0 '` �� `v� `�F .\� \�� a i. c� _ 2�s- �,, ,'1`�IT�E B l�J r i '' `�'� 1C =11� � '+.rli � Dc � , .�5, �', � .ti��c��� - ' °j '`, � -� �a.r;��� g� o_ �' �- ° ��o ;�° ,�.� o,;� •�¢'73� ` �C 6'6 ' � `S \ PAQ=:110.0 h� . -� :�' 1 � � �� s- � TYPE A ~ o FF=1t0_30 . .�� t�� e - ' � � : � s,^ ' � LOT 13 � �} E r,'���. � _20 ' , _--i-_---, � � • �LOT 0.80 FF=11�.60 TYPE A t5 � �r � PAQ=109.6 `L �;'• � '� �° ' FF=10$�i� � '� O. � PAD=110.1 PA�109.9 1 '`•� 1 '\ , ��� w - - PAD�T � � o� � `�� TYPE A TYPE A �1 � r ,� � �a � � - o� , c�`t�\` ,�j b�-,' �� '�_ _ � o� 6 . ��.°�� �+�� � C i o J ,c� ' �,0 6 �� ,q�'1 'l� � .� 1� �ti B"v� � � I � � ., _� �o o ��. v• . _ � a-Y c,� �� _-� 'r o +. - � � a � --- 6 '` - ,•, Ak� �,1 � _` 1 ��� i'�$ .1 '.-- T ;10 rJ� c �b.� � � e^� ' '_ � � . � � -' " . r'' _��T6e_33 � .y'� ������6.n 20� DRAlNAGE FASEMENT � oa s -'�� _�="_'_-- ,�O i � t� �6,�`` -�'---�-�----- }� �j ,�. , 10' 1177 -EAScMENr `°c'-9�' ��r p O yY`, L.� -�1 n`rC'i-n ^ !`n. . . �, � „ ',���.� ` ��' '_--��'� ` � ; �7 os.8o ` t� � 1 � _h � � . \ � �,,, o$� _�,�i� � �- �T 9 � � ,• 6 �� -�� � �1 " 'O' D a- � 108.1 J ,g � '�! 1 'v Ft A• - '� � � . '.�� tA� a- �Pf B 1V ' ' __ .--- � ` ' � `� � ' n� �O` � �� � w s "-r^-- 1 `_ `� r� ' ; �1y , ,��, �'�z' _ "_ , ' - .. ", �� _ _ � � - � -- -- .' i 0' UTlUTY E ,� _-� � � ' ' �[ �� q P - , - ,' - _��'L_� - _ ` 1 7�(88.8 . - - FF=109_90 • �_ 'r �,s �. � F��1as�` _. . LOT 1 ` t ` , r 'Z� 'S�" L T% --FF=1 10.�6 � PAD=109.2 1 a� � A,s- FALZ,�.d8.3 FF=1�9_20 , FF=1t0.2Q� ` FF=114.5d LOT 2 T1'PE 8 �� ' ;.°� =3• r TYPE��... , L T 7 FF=11�.50 F= • 50 , ,.- �. �O LOT u' ti F t i o_3a� ��1 --�- LOT 5 PAD=109.d � � �s � A PA�-7 08.5 . ••PAD- �t8. PAB= 18 LOT 4 LOT_3"� -�ypE B c, 0�• '' 3� -._ C� ��TYPE B ��8 � PA�=t09.8 . PAD=109.6 Gg� �1 �'� �r , ,_ ' ^ T'��'-9 TYPE BJ�I- TYPE B �C7- �"4.'�O �S �� �� C�'• ' >>��- ' � '� '� 107, d- �rO � - O�ir , . _ _ - � � T �19^' '\ ����� ��v�r %`�� ,' _ _��"' - """' '- �' _ E \1 '-� r `� _`o,, �, Y � �=-� .. Q� � 4 � `, �� o. . .,, - �. � � - i ��Q,sL�� C7��` � �-u, ,9. r 1� T\ _'1^ ,'� r �O �h'v� ' C� 18'(87. .- 6!� \ �J�'��� �� e��' � - - - - _-- �:..�c _�--- - �� - ---.•�' �' � , WETLA1�lD �� � �� . �T: . __ - ,` -r �� -` � � CONSERVATION ����4:���'��� r�� .�$- ,Y - �;�� ��G�'��'� ��� `�e' d'� ��11' _�� r , /' ��a o't7�-[}a��� ,� . AREA P � ✓ -�� ��,,g , ..�-� ,�. �����. � �'• 'r .,t i• ' °t , '°'�� �'''r r, ' r ��/c.��/ { � vi (�� �°� _ �si ,, -.�� ��Y •� . �6' � " 6 O � �L" � `` ����� 7.� �� n?'� PI� Q�6• C7 ' -��a+� � (1 .22) AC. _ _ __. -- .\ �,, ` - �, "y_--�,_,�c r� ��. �..._ .�J,r . o ' tC ' � � q7' 'Y � � ' 9-e- .r� s r�r .� �� � - , J ODYROHW=104.0 __, ., ,__ . COl\+7ROL S7RUCTUR�C ��s' � `�O - •� a �- o,-�%��fi- . _ � - . -� r� . � . -_ __ � •a`� c�' s - '4;' � ' '- \�� � � a- ..__ ------ � �j�s- �- '�.� 8� S . . �1 `_'� � 'E� S �6.1 '� F� - � ' C' 'o`���T � l it- .� `°' � �,' , _ . _ _._ . • . _ .., - � . . . . . _ : - � - - - - - ------ - - . ... -- -- - + - - ,- �s - ps- - - - _ • ---•-_. A/7 CF Al7[7Af C " a�6" �� - ��_5a16' ,,. • � 5335-$TH STREET (813)78Q-QO20 CERTIFICATE OF OCCUPANCY Address: 6477 PADEN WHEEL ST t3wner: LENNAR HOMES LLC ZEPHYRHILLS, FL. 4640 W CYPRESS ST STE 200 Subdiv: SILVERAD(3 TAMPA, Fl. 33607-4099 Parcei: 05-26-21-0074-Q0400-002Q Work Type: 101-NEW CClNST/SFR Gonstruction Type: NOT APPLiCABLE ❑ Sprinkiers Use Ciassification: NOT APPLICABLE Permit Number: 18982 Dat . 3l28l2Q 18 f , . J ��. . � ISSUE BY: BUILDIf) "� C?FFICIAL, : WATER MUST BE CiiANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE QEP4SIT MUST BE APPLIED Ft�R PRI4R TC? ISSUANCE