HomeMy WebLinkAbout17-19001'� CITY OF ZEPHYRHILLS
, � 5335-STH STREET
- . := �sis)�so-oozo 19001
; : , BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
- PERMIT�INFORMATION - - LOCATION INFORMATION� �
Permit#:19001 Issued: 11/13/2017 Address: 6620 PADEN WHEEL ST
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 342,230.70 Total Fees: 11,736.69 Subdivision: SILVERADO
Amount Paid: 11,736.69 Date Paid: 11/13/2017 Parcel Number: 05-26-21-0070-00300-0070
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA FL 33607-4099
Phone: (813)574-5743 Lic: Phone: 813-574-5700
Work Desc: CONSTRUCT SINGLE FAMILY 3,038 SQ FT
APPLICATION FEES
BUILDING FEE 1,321.33 EL CTRICAL FEE 273.83 P MB G FEE 182.55
MECHANICAL FEE 127.79 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfd100% 4,828.00
SCHOOL IMPACT FEE-sfr/1% � 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
(
�V -
/ �
� �
�
Ins ections Re uired�
FOOTER 2ND ROUGH PL MB MIS INSULATION CE G
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
� first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
--�.
CONTRACTORS IGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
s�s-7ao-oozo �, ' ` City of Zephyrhills Permit Applicatian Fax-$13-780-0021
' Building Department
Date Received Phone Contact for Permitting ��3 363 _ 2891
1 1 ! ! 1 I i ! 1 ! t t i
4wner's Name �ennar Homes,LLC Owner Phone Number g13.S74.5700
Qwner's Address ¢����`��ress St.Ste.24Q,'Tampa,PL 33607 pryner Phone Number � �
Fee S9mple Fitlehalder Name N!A � Owner Phone Namber �� �
Fee Simple Titlehalder Address N/A
JOB ADDRESS 6620 Paden Wheel Street LQT� 0070
SUBDIVISION Silverado Ranch Subdivision Ph 2,3,84 pARCEL ID# �5-26-21-0070-00300-0070
{OBTAINED FR4M PROPE}2TY TAX NOTtCE}
WORK PROPOSED II./ II NEW CONSTR 8 ADD/ALT � SIGN Q � pEMOLISH
� INSTRLL REPAIR
PROPOSBD USE �� SFR Q COMM C� OTHER
TYPE OF CON3TRUGTION � BLOCK 0 FRAM� � STEEL �
p�SCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence
BUILDING SIZE U/R SF �Q38 SQ F4QTAGE 2277 HEIGHT 1 Story �
✓ BUILDING � ��,,,? �� VALUATION OF TOTAL CONSTRUCTION
�ELECTRICAL �� � PROGRESS ENERGY 0 W.R.E.C.
AMP SERVICE
�PLUMB(NG �;y�
L
[�MECHANICAC. �;p � VA4.UAT(dN OF MECHAN(CAL INSTALLATION � ����
L
�GAS � ROCI�ING Q SPEClALTY � OTHER
FINISHED FLOOR ELEVATIONS � � FLOOD ZONE AREA �YES nV0
t_I
■ • . . . . .
_�. ......
BUtLDER COMPANY Lennar Hames,LLC
SIGNATURE �--� REGISTERED Y/ N FEE CURRE� Y/IV
Address 4600 W.Cypr ss St.Ste.200,Tampa,FL 33607 License# CGC1518166 y ��
E�ECTRICEAN � Cq}�ppHy Edmartsan Electric, Inc.
SIGNATURE REGISTEREp Y/ N FEE CURRE� Y/N
Address 1fl34 Skipper oad,Tampa, FL.33613 �icense# �C1300540$ �
PLUNfBEE2 -`. COMPANY ��y���t Plumbirtg, Heating &AC, Inc
SIGNATUF2E REGISTERED Y/ N FEE CURRE� Y/N
Address P.O. Bax 530 , 8�yonet, FL 34674-5308 ticense# CFCq42998 �
MEGHANtGAL �p�pA�Y Bayanet Plumbing, Heating &AC, lnc
SIGNATURE REGISTEREp Y/ N FEE CURRE� Y/N
Address P.O. Box 5308, �yortet, FL 34674-5308 ucense# CAC058062 y�
OTHER CONIPANY
SiGNATURS REGISTERED Y/ N FEE CURRE� Y/N
Address �2�9 Shoa! Lirte Ivd, Sprirtg NiEI, FL 346Q7 �icense# CCC057991 ��
0111111111111111111111111111111111111111111111111111111811111111111
f2ESIDENTlAL Attach(2)Plot Plans;(2)sets of 8uilding Plans;(1)seY of Energy Farms;R-fl-W Permit for new construction,
Minimum ten(1 d}working days after submittal dafe. RequireH onsite,Construction P(ans,Stormwater Plans w/Si(t Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisians/large projects
COMMERCIAL Attach{2)complete sets of Building Plans plus a Life Safety Page;{1)sei af Energy Forms.R-Q-W Permit for new construcfion.
Minimum ten(10}warking days after submittal dafe. F2equired onsite,Consfruction Pians,Stormwater Plans wl Silf Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SlGN PERMlT Attach{2}sets of Engineered Plans.
*""'PROPERTY SURVEY required for a((NEW construction.
_Y � ..■ / Y • • Y • ■ • • Y •_■ • � ■ • • Y .�
Directions:
Fili ou#app(icafion campletely.
Owner&Contractor sign back of application,notarized
If over$250Q,a Nottce of Commencement Es required. (A/C upgrades over$7504j
`* Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING {copy of contract required}
Reroofs if shing(es Sewers Service llpgrades A/C Fences(PIof/Survey/Footage}
Driveways-Not over Counter if on pubiic roadways..needs ROW
fVOTICE OF DEED RESTRICTIONS The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for cor�pliance,with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IfVIPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understooci that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is �
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to.
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone"V" unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air �onditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension If work ceases for ninety(90) consecutive days, the job is considered abandoned.
WARNING TO 01f1/NER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AfV ATTORNEY BEFORE RECORDING YOUR NOTICE OF COM ENCEMENT.
FLORIDA JURAT(F.S.117.03)
OWNER OR AGENT v CONTRACTOR �—
Subscribed and sworn to(or affirm )before me this Subscribed and sworn to(or affirmed)be re me this
u�-��t-�� by paul Sweene os-o��-,� by Paul Sweeney
Who is/are personally known to e or#�asl#ave�edt�ced- Who is/are personaliy known to me or
as identification. as identification.
Notary Public Notary Public
Commission No. FF98537 -- Commission No. FF98537
Elissa M.Holleran Elissa M.Holleran
Name of NotaN tvped,printed or stamped Name of Notary typed,printed or stamped
- � - '' � ��I��k�I��fpt�E�N'
6lI��W.GI�lhE�11�' � � �C#t��T+Yd�4e��I�I�p�D�7
,*��mr��:�ania,��A�BAp�' I � i�qp��dYrr���'��4�d
��J�.k4�1uP�f�b'��ip�d _ , � B�i�d71NT�ayF�lelvoaAdelitUMS�II ,
'' � -- 6a�d�9�Yrlf.rv,�Filnlwo��FDiWN�fiGII , _ . - _ ,
e r „'V" ."��"`?i� f.
. �
- .;����`�i:
- _��� �_. ,.w ,sv
���::;w -
, «�;�" -'�' .
_ i !
�`a.
City of Zephyrhills
BUILDING PLA1V REVIEW COMMENTS
Contractor/Homeowner: ��.�� 4/��—
Date Received: l o—����7
Site: � � �C� 1 GCL'�-P,t�l (�l�,`����
�
Permit Type: ' �S( `�..�� � Z Z�� S �
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑
��� 5���
This comment sheet shall be icept with the pernut and/or plans.
�
/ � �������
Y{alvin S�uit lans Examiner l�ate Contracto arid/or Homeowner
(Requi ed when comments are present) �
,
Pasco couN�nr
�;;�:}=y,.� DEVELOPMENT SERVICES
� ��''v,�' 8731 Citizens Drive Date:2/2212018
COUN'I'Y FL012IDA New Port f2ichey,FL 34654
t�r.w�s Sr,u�rs.[!ru�r�Nr 1't,�c.�c, 727-847-249 7
** [�C�1" A P�RMIT' *�'
�
Receipt#: 1739637 �
FEE DESCRIPTION ACCOUNT CODE U ITS INVOICE# FEE AMOUN7 PAID RECEIPT# DATE
(mpact Fee Residenfial Solid 2456390d-329010 5A.74 1321799 $2�3.70 $273.70 1739637 2/22/18
Waste Single Family
TOTALS: 5273.70 $273.70
Reseiat# Paid Bv Check# CC Auth# Cashier ID Workstation Receiut Date mt Paid
1738637 Check 00358013 640 BCCCP06W 02(22/2018 $273.74
Total Payrnents: $273.70
Pa or Address hane �
Lennar Homes LLC q600 W Cypress Street Suite 200
Tampa F13S607
Comments'
b,� City af Zephythllls � � � � �--� -
� Permit 18982, '� j
6477 Paden Wheel St.
�p-� Permlt 190q1,
6620 Paden UVheel St.
�a� Permit 19138,
6601 Sflverado Rahch Blvd.
3�� Permit 1 s247,
6646 Paden WheelSt.
Permit 19250,
,��� 6623 Sllverado Ranch Blvd.
While yau wlll be paylnII Your blll wlth Pasco Cqunry pavelopment Services,the full emount of the uedit Card or rsheck fees,NOT ahown a6ove,Is collected 6y
Pirst S}I#G+g paymen#services.
MyRepo�tslreports//PRODUCTION/PASCO/ReoeiptPCaS V5.tpt 2/22/2018 Page 1 of 1
, �
- • Lennar Homes-6620 Paden Wheel St-3,038 sq ft
o umn
SQ. FEET PRICE
MAIN OR LIVING: 3,038 $ 112.65 i
OTHER AREA UNDER ROOF: - $ 88.00 '
OTHER: - $ -
VALUATION $ 342,230.70
FEE SHEET $ 1,217.00 �,
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,321.34
ELECTRICAL: $ 273.83
PLUMBING: $ 182.55
MECHANICAL: $ 127.79
SUB-TOTAL $ 1,905.50
TOTAL $ 1,905.50
SEWER: na
WATER: na '
IRRIGATION: $ -
TOTAL: $ -
WATER METER: na I
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: na
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 2,458.85
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28
T I F'S : $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 11,736.69
- - CITY OF / / I I BUILDING
ZEPNYRHILLS DEPARTMENT
OF ADDITION OR CORRECTION
� • s - •
qpp � DATE PERMIT
�Z� �l � �-z-r �v l
THIS JOB HAS��NOT BEEN COMPLETED. The following additions or corrections shall be made before the job
will be accepted.
/
� k ��.d� �� �v,�
�
It is unlawFul tar any Carpenter,Contractor,Bui�der,or other persons,to AFTER CORRECTIONS ARE MADE CALL
cover or cause to be covered,any part of the work with flooring,lath,earth 7$0-�02� F RE-IN ECT N
or other material,until the proper fnspector has had ample time to approve
the instellaUon.
OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR
OS-26-21-0070-00300-0070 � Pasco County Property Appxaiser Page 1 of 1
, �.
Data Current as Of: Weekly Archive - Saturday, October 28, 2017
Parcel ID 05-26-21-0070-00300-0070 (Card: 001 of 001)
Classification . 00�- Vacant Residential
Mailing Address - �� Property Value
LENNAR HOMES LLC Ag Land $0
4600 W CYPRESS ST STE 200 Land $26,783
TAMPA FL 33607-4099 Building $0
Physical Address Extra Features $0
6620 PADEN WHEEL ST
ZEPHYRHILLS, FL 33541
7ust Value $26,783
Legal Description (First a Lines) Assessed (Non-School Amendment i) $26,783
SILVERADO RANCH SUBDIVISION
PHASES 2, 3 &4 PB 73 PG 059 Taxable Value $26;783
BLOCK 3
LOT 7
Jurisdiction
City of Zephyrhills
Land Detail (Card: 001 of 001)
Line _ iUse� Description�Zoning Units Type _ Price Condition Value
1 _ _� 0100 SFR� MPUD 6,000.00 SF ' $4.25 1.00 $25,500
2 � 0100 SFR MPUD 3,889.00 SF $0.33 1.00 $1,283
Additional Land Information
Acres 0.23 Tax Area�30SI i C de � I Residential Code SLVRLPI
1
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
Extra Features (Card: 001 of 001)
Line � Description Year Units Value
No Extra Features
Sales History - See All 6 sales
Previous Owner: DUNE FL LAND I SUB LLC
Month/Year Book/Page � Type T��DOR Code Condition �Amount
10/2��0�17���������9620 / 2310' Warranty Deed ; 05 ` Vacant Multi-Parcel Sale
09/2011 ' 8606 / 3376 Warranty Deed � 05 � Vacant Multi-Parcel Sale
05/2010 i 8373 / 1912 I Certificate of Title �� 12 � Vacant � $0
http://search.pascopa.com/parcel.aspx?parce1=2126050070003000070 11/2/2017
, 6620 Paden Wheel St
o umn
SQ. FEET PRICE
UNDER ROOF: 3,038 $ 112.65
OTHER: - $ -
VALUATION $ 342,230.70
FEE SHEET $ 1,217.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,321.34
ELECTRICAL: $ 273.83
PLUMBING: $ 182.55
MECHANICAL: $ 127.79
SUB-TOTAL $ 1,905.50
TOTAL $ 1,905.50
SEW ER:
WATE R:
IRRIGATION: $ -
TOTAL: $ -
WATER METER:
IRRIGATION METER
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 2,458.85
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28 -
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 11,736.69
�" .. —
+ . i���ii�ii���iirii ti��f�ii��i E��4�r��«tiiiii iiiti��i��i�iii���ti
� . 2017168297
�cpt:7tyY7�+169 xTe°0.00�t�Y1
p5: 0.00
�,@/25/2017 K. K. , Dpty Clerk
. ��----- __
� .. � ' /HULH b V'i3t1L�t'h U NHliGU (;L�tiKO�G1f'IF�TT2(SCLEk
10 OR BK 1�7r ���rn ��' ����
'+� .__.._—,_—__ .�----- �
- _���—
' Permit No. Parcel!D No Q5-26-21-0470-00300-OQ70
NOTICE �F COMMENCEMENT .
state of Florid� county or Pasco
, TFtE UNDEE?SlGNED hereby gives notice that lmprovement will be made ta certain reaf property,and in accordance wittf Chapter 713,Florida Statutes,
-_ the following informatian is provided in this Notice of Commencement:
1. Descriptian of Property: Legal 51LVERADO RANCH SUBDIVISION PIiASES 2 3.&4 PB 73 PG 59 BLOCK 03 LOT 07
sc�e�caad�ess. 6620 Paden Wheef Street Zephryhills FL 33541
2. Genera!Descriptlon of lmprovemeni Single Family Residence!Pao!!Screan Enclosure!Fence
3. Owner Information: Lennar Homes, LLC.
Name
4600 W C�rpress St. Ste 200 7ampa FL 336Q7
Address City State
(nterest in Property�
' Name of Fee Simple Titleholder• N�A
(If atner than owner) , _
+ Address City State
�. contractor� Lennar Nomes, LLC
" Narne
� 4600 W�Cypress S#, Ste 200 � Tampa FL, 33607
� Address . ' City State
� Contractor's Telephone No. 813.574 5700
5. surety- N/A '
Name
- Address � City State
� �
Rmount of Bond: $ Telephone No..
_ s ~ . �ender N/A �
Name
Address Cify State
Lender's Telephone No.:
7. Persons within the State of Florida designafed by the owner upon whom notices or other documents may be served as provided by
Section 713.13{1){a){7},�lorida Siatutes:
" Lennar Homes LLC �
Name
_ 4600 W Cypress St, Ste 200 Tampa ' FL, 336Q7
Address City State
Telephone Number of Designafed Person: $�3.574.570Q
8. tn addition to himself,the owner designates N/A of
tb receive a copy of the Lienor's Notice as pravided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entiry Designated by Owner:
' 9 Expiration date oP Notice af Commencement is one year from the date of recording unless a different date is specified:
WARNWG TO OWNER: ,ANY PAYMENTS MADE BY,TNE QWNER AFTER THE EXPIRATIdN OF TNE NOTICE OF COMMEiJCEiV1ENT,
ARE CONS(DERED 1MPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YQUR PAYING TWICE FOR !NlPF20VENlENTS TO YOUR PRQPER"f1'. A N4TICE OF C4MNiENCEMENT MUST BE
RECORDED.AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION: IF YOU,IN7END TO OBTAlN FINANCING,CQNSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE CflM(VfENClRlG WORK OR RECORDING YOUR NC1TiCE QF COMMENCEMENT
STA7E OF�LORIDA "
COUNTY OF PINELLAS .�.._.--�-'�
8ignature of Qwner or Owner's Authorized Officer/QirectorlPartnerlManager
Vice Presiden#
� ` Signatory's Title/Office
The foregoing,instrumenC was aoknowledged before me thi� � day of MarCh �,t1�1 ,by
Steve Robert Smith as Vlce President (type of authority,e.g.,officec,trustes,aktorney in fact)for
Lennar Homes LLC ' ' �ame of party on be who ' strumentwas executed)
Personally Known�'OR Produced ldentification 0 Notary Sign �~'�
Type of Identification Produced tvame(�rint}� EIISSa HOIlet'�C!
Verifcation pursuant to Section 92.525,Fiorida Stafutes. Under penaities of perjury, (.dec(are that I have read the foregoing and that the facts stated in
ik are true to the best.of my.knowledge arid belief.
� ^ ��� ,, .,-f-_..�¢"' ^-��.�
, . ;��, ELISSAM.HOLL�RAN Signature of Natural Person Signing Above
_�_ ;�Gmmlwsion#FF 885837
''�-�J(��f93Jtltt6�����{�
wpdata/bcs/bcs form:, +�°�I��''' 9ondeiihNTrorFolnlManncelR4�3i5-741P �
>=
�
- sr�r�or�Lo�s��, c:our�rv����,.�co
THlS IS T0�CERTIFY THAT THE FOREGOING IS A
����0����p�� `` TRUE AND CORRECT COPY OF THE DOCUMEfvT
ON FILE OR OF PUBLIC RECORD IN THIS OFFICE
� • ��'''k' '� �P' WITNESS MY HAND AND OFFICIAL SEAL THIS
���, ��;�
�.
� o � �:. ��DAY OF 2 �.�.1
In `� ,' ��c'>*�� PAULA S. O'NEIL, CLERK&COMPTROLLE�
� Go�,�, - `� .
e�-,x,�r�.
.'��� BY /
�3r ° ' � DEPUTY CLE�K
�'��'��� ��
o �, �
�� ,
'���a�����,.��
Single Family Dwelling
Plan Review Comments
1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan.
2. Lots shall be graded to comply with R401.3 of the F.B.C.
3. Compaction test required if 24" or more of fill dirt is brought in at any one place.
4. Tie in survey required before pouring concrete.
5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have
expansion material.
6. All setbacks shall be met.
7. All property markers shall be uncovered and marked at time of first inspection.
8. All A.D.A. requirements shall be met.
9. No electric, plumbing,mechanical, or framing shall be covered without an inspection and
approval first.
10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).
11. Appliances shall not be installed in a location where subject to mechanical damage unless
protected by approved barriers. M303.4 of the F.B.0
12. Water heaters shall comply with section P607.3 of the F.B.C.
13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1
14. Return air in all bedrooms. F.B.C. M1620.4
15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C.
16. All glazing requirements are to be in accordance with R308.4 of the F.B.C.
17. All means of egress are to be in accordance with R311 of the F.B.C.
18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C.
19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker.
20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating
or appliances or an attached garage. They shall be installed in accordance with the F.B.C.
21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all
underground plumbing and electric.
22. A112008 N.E.C. Codes will be enforced.
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0
24. In accordance with the Land Development Code, lots shall be sodded before final at least 10
feet around the structure.
25.A copv of the ener�v cacls shall be with permit at all times.
26. Conv of final insulation renort shall be provided in with permit before�na�
F.F.E.-Finished Floor Elevation
F.B.C- Florida Building Code 5�'Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008)
PASCO COUNTY, �LORIDA
Permit No. �1911 U (
� Date Permitted //�Z_��
Builder Name/Owner Name �p/�tvrCC�- ��g� Control#
County Parcel No. �S� 2(,-Z/_�j p�o„��3d p � �- (,.,,__,�II
��p SubDiv: �W�t 2
Address/Location (e� ��,� ����` ��
Classification/Type of Use �;r�q �� ����
�
TRANSPORTATION IMPACT FEE . Rate:
Sq.Ft Unit: �, d�
Exempt � Yes [� No How Determined �—
� Impact Fee Amount $, 3r�� Zone No.
— __ TAZ:
SCHOOL INiPqCT FEE
Account (056) Single-Family Detached House Amount $ � � '�(o, Z�
(057) Mobile Home
(058) Other Residential
123) Collection Fee
Exempt Yes � No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit
Land Total
Recreation Account �_ Recreation Credit
__ Recreation Total
Zone ---
-- TOTAL AMOUNT $ ?(�9 S�
Exempt � Yes � No How Determined
LIBRARY FEE
Land Account Land Credit
Land Total
Facility Account __ Facility Credit �
Facility Total
Exempt � Yes � No How Determined
__ Total Amou�
RESOURCE FEE
TOTALAMOUNT ERU
Prepared By Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE I
RECEIPTED FOR BY A CENTRAL E MIT7'NG OFFICE.OF PASCO COUNTY I,
Acknowledgement below does not Imply acceptance of concurrence,but simply recelpt of a copy of this form,placing I
the building permit owner on notice of this assessment and the conditions of payment for same. I
DATE
RECEIVED BY
RECEIPT NO. __ pATE
�_ BY
r �_ '
FORM�R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
0307
Project Name: 2268AB sf ADS Buitder Name: LERltJAR HOMES
street: 6620 Paden Wheel Street Pe���Q��� PasCo
Gity,State,Zip: ,FL, Permit Number: j `�Qa {
Owner LENNAR HOMES Jurisdiction: (11C)OQ
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Pians) 9. Wall Types(2268.0 sqft.) Insulation Area
2. Single fami(y or mu(tiple family Sirrgle-family a.Concrete Block-Int lnsul,Exterior R=�4.1 99Q4.00 ft2 ,
b.Frame-Wood,Adjacent R=11.0 364.00 ft
3. Number of units,if multiple family 1 c.N/A R� gz
4. Number of Bedraoms 4 d•�JA R= �z
' 10.Ceiling Types (2267.0 sqft.) Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2267.00 ftx
6. Gonditioned flaor area a6ove grade{ft�} 22&7 b.NiA R= ft2
2
Conditioned floor area below grade(ft2) 0 �1 cQ�cts R� � �2
7 Windows{277.0 sqR.) Description Area a.Sup:Attic,Ret:itltain,AH:Main 6 453
a. U-Factor Dbl,U=0.54 143.00 ft2
SHGG: SHGC=0.31
b. U-Factor DbI,U=0.58 96.00 ftx 12.Caoling systems kBtuJhr E�ciency
� SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00
c. U-Factoe Dbl,U=0.56 38.00 ft2
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor. N/A ft2 a.Electric tiea#Pump 32.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 4.206 ft.
Area Weighted Average SHGC: 4.309 14.Hot water systems
a.E(ectric Cap:40 gailons ,
8. Floor Types (2267.0 sqft.) Insulation Area EF 0.950
a.Slab-On-Crade Edge Insulation R=0.0 2267.00 ft2 b. Ganservation features
b.NJA R= �2 Nane
c.N/A R= �2 15.Credits Pstat
Glass/Floor Area: 0.122 Total Proposed Modified Laads: 75.57 pASS
Tota!Basel9ne Loads: 76.32
1 hereby certify that the plans and speciftcations covered by Review of the plans and ���'k1�:ST.q�.�, ..
r �� Q ,'
this calculation are in compliance with the Florida Energy specifications covered by this _�' ,, ^.4 y� �,.
Code. calculation indicates compliance r'�'`r„-''' `==��`;��` ,��a.
� �l '?tis.'�1\ L .
�aVe �,j�G� with the Florida Energy Code. .�+� r�t;,�`rr;;;;;�.�,.�"-�ti �
PREPARED BY �W� Before construction is completed r� � � "� �"°"`�'� �
this buildin will be ins ected for � !� � �
DATE. 9 p t7 �'�z�`�� " ��� �
compliance with Sectian 553.908 * �'�: ` �.
1 hereb certi thaf this buildin as desi ned, is in com liance ��Qrida Statutes. r„ �:
with the F(arida Energy Cade. 9 9 P "��,������- ,,'
OWNER/AGENT. t � BUlLDWGQ,FFtC1AL: ��!�k� . .
DATE: � J DATE: !l` l
- Compliance requires certification by#he air handler unit martufacturer that the air handler enclosure qualifies as
certified faatory-sealed in accordance with R403.2.2,1.
-Compliance requires an Air 8arrier and Insulation tnspection Checklist in accordance with R402.4.1.'! and an envelope leakage
tesf report in accordance with R402.4.�1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accardance with Section 803 of RESNET Standards,is not greater than 0.060 Qn for whole house.
9/25/2017 9:55 AM EnergyGauge�USA-FlaRes2014 Section R4p5.4.1 Compliant Software Page 1 of 4
' } .
FORM-R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential PerFormance Method
0307
Project Name: 2268AB sf ADS Builder Name: LENNAR HOMES
street: 6620 Paden Wheel Street Permit o�ice: pasco
City,State,Zip: ,FL, Permit Number•
Owner LENNAR HOMES Jurisdiction: 611600
Design Location: FL,Tampa County:. Pasco(Florida Climate Zone 2)
1 New construction or existing New(From Plans) 9. Wall Types(2268.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1904.00 ftz
b.Frame-Wood,Adjacent R=11.0 364.00 ftZ
3. Number of units,if multiple family 1 c.N/A R= �{_
4. Number of Bedrooms 4 d.N/A R= ftZ
5. Is this a worst case? Yes 10.Ceiling Types (2267.0 sqft.) Insulation Area Z
a.Under Attic(Vented) R=30.0 2267.00 ft
6. Conditioned floor area above grade(ftz) 2267 b.N/A R= ftZ
Conditioned floor area below grade(ft2) 0, c.N/A R= ftz
11.Ducts R ft2
7. Windows(277.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 453
a. U-Factor Dbl,U=0.54 143.00 ftZ
SHGC: SHGC=0.31
b. U-Factor Dbl,U=0.58 96.00 ftZ 12.Cooling systems kBtulhr Efficiency
SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00
c. U-Factor: Dbl,U=0.56 38.00 ftZ
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 4.206 ft.
Area Weighted Average SHGC: 0.309 14.Hot water systems
8. FloorTypes (2267.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF 0.950
a.Slab-On-Grade Edge Insulation R=0.0 2267 00 ftz b. Conservation features
b.N/A R= ft2 None
c.N/A R= ftz 15.Credits Pstat
Glass/Floor Area: 0.122 Total Proposed Modified Loads: 75.57 pASS
Total Baseline Loads: 76.12
� -
I hereby certify that the plans and specifications covered by Review of the plans and �Tk�:ST�q7, ..
this calculation are in compliance with the Florida Energy specifications covered by this � `�v��: � _.,�;;�0�_�.,
Code. calculation indicates compliance • �'��,;,�''; `==a:����:� .
�aVe ���G� with the Florida Energy Code. ' d: �r�rri�+�1��,�:::r�".�;;���'���ti O .
.,��� A .
PREPARED BY: Before construction is completed � •, ' '� �
DATE: this building will be inspected for � �7���- `. :�
compliance with Section 553.908 ' *� �. :- -,*
I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. ��
Y fY 9� 9 P � ;'�. _ . . .
with the Florida Energy Code. C�D�y�t�'�� -
OWNER/AGENT� BUILDING OFFICIAL: ��CC� -
DATE. DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards,is not greater than 0.060 Qn for whole house.
9/25/2017 9:55 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
i � � •
FORM�R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential PerFormance Method
� Project Name: 2268AB sf ADS Builder Name: LENNAR HOMES 0307
street: 6620 Paden Wheel Street Permit o�ice: pasco
City,State,Zip: ,FL, Permit Number•
Owner. LENNAR HOMES Jurisdiction: 611600
Design Location: FL,Tampa County:. Pasco(Florida Climate 2one 2)
1. New construction or existing New(From Plans) 9. Wall Types(2268.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1904.00 ftz �
b.Frame-Wood,Adjacent R=11.0 364 00 ft2
3. Number of units,if multiple family 1 c.N/A R= ftZ
4. Number of Bedrooms 4 d.N/A R= ft2 I
5. Is this a worst case? Yes 10.Ceiling Types (2267.0 sqft.) Insulation Area 2
a.Under Attic(Vented) R=30.0 2267.00 ft
, 6. Conditioned floor area above grade(ftZ) 2267 b.N/A R= ft2
Conditioned floor area below grade(ftz) 0 c.N/A R= ftz
11.Ducts R ftz
7. Windows(277.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 453
a. U-Factor: Dbl,U=0.54 143.00 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.58 96.00 ftZ 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00
c. U-Factor: Dbl,U=0.56 38.00 ftz �i
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor� N/A ft� a.Electric Heat Pump 32.8 HSPF:8.50
, SHGC:
Area Weighted Average Overhang Depth: 4.206 ft.
Area Weighted Average SHGC: 0.309 14 Hot water systems
8. FloorTypes (2267.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF 0.950
a.Slab-On-Grade Edge Insulation R=0.0 2267.00 ftz b. Conservation features
b.N/A R= ft2 None
c.N/A R= ftz 15.Credits Pstat
Total Proposed Modified Loads: 75.57 pASS
Glass/Floor Area: 0.122
Total Baseline Loads: 76.12
I hereby certify that the plans and specifications covered by Review of the plans and : ��;T�:$T�j�.� -.. I
this calculation are in compliance with the Florida Energy specifications covered by this � ' ��' , , � = 0�,,
Code. calculation indicates compliance �"�+'�;,,��'' ,�.�::�,�����.,*s+r,
�ave ���G/, with the Florida Energy Code. �+ »rr'r �:'%%-.,,��",�';����titi O
PREPARED BY �� Before construction is completed r� � �, '� "-`�""'" �
�' - � �(� ��__ . �- C
DATE: this building will be inspected for � �I',;�� �.
compliance with Section 553.908 ' *, -� '�. =.�
I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. �
Y fY 9� 9 P , � �
with the Florida Energy Code. -_ C�D�yy�'1'��-
OWNER/AGENT: BUILDING FFICIAL:
DATE: DATE: - -
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accardance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards,is not greater than 0.060 Qn for whole house.
9/25/2017 9:55 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
( � , '
FORM R405-2014
PROJECT
,
Title: 2268AB sf ADS Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 2267 Lot#
Owner. LENNAR HOMES Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: LENNAR HOMES Rotate Angle: 0 Street:
Permit O�ce: Cross Ventilation: No County: Pasco
Jurisdiction: Whole House Fan: No City,State,Zip:
Family Type: Single-family FL,
� New/Existing: New(From Plans)
Comment:
CLIMATE
� IECC Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site Zone 97.5°/a 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Blockl 2267 21083.1
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated
1 Main 2267 21083.1 Yes 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 242 ft 0 2267 ftZ �_ 0.3 0 0.7
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
�� # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2535 ftz 0 ftZ Medium 0.85 No 0.9 No 0 26.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 2267 ftZ N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 2267 ft2 0.1 Wood
9/25/2017 9:55 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
t ' ' I
FORM R405-2014
� WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
1 N Exterior Concrete Block-Int Insul Main 4.1 12 8 9 4 118.2 ft2 0 0 0.6 0
2 S Exterior Concrete Block-Int Insul Main 4 1 31 4 9 4 292.4 ftz 0 0 0.6 0
3 E Exterior Concrete Block-Int Insul Main 4.1 64 0 9 4 597.3 ftZ 0 0 0.6 0
4 W Exterior Concrete Block-Int Insul Main 4.1 75 9 4 700.0 ft2 0 0.6 0
_ 5 N Garage Frame-Wood Main 11 28 0 9 4 261.3 ftz 0.23 0.01 0
_6 E Garage Frame-Wood Main 11 11 0 9 4 102.7 ft2 0.23 0.01 0
7 N Exterior Concrete Block-Int Insul Main 4.0999 4 8 11 4 52.9 ft2 0 0.600000 0
8 S Exterior Concrete Block-Int Insul Main 4.0999 15 4 9 4 143.1 ftz 0 0.600000 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N Insulated Main None .2 3 6 8 20 ft2
2 N Wood Main None 4 2 8 6 8 17.8 ftZ
WINDOWS
Orientation shown is the entered orientation => chan ed to Worst Case.
/ Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
, 1 N 7 Metal Low-E Double Yes 0.56 0.28 6.0 ft2 5 ft 0 in 0 ft 8 in None None
2 N 1 Metal Low-E Double Yes 0.56 0.28 32.0 ft= 1 ft 0 in 3 ft 0 in Drapes/blinds Exterior 5
3 S 2 Metal Low-E Double Yes 0.54 0.31 48.0 ftZ 1 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5
4 S 8 Metal Low-E Double Yes 0.58 0.32 96.0 ftz 10 ft 0 in d ft 2 in Drapes/blinds Exterior 5
5 E 3 Metal Low-E Double Yes 0.54 0.31 23.0 ftZ 1 ft 0 in 0 ft 8 in None None
6 E 3 Metal Low-E Double Yes 0.54 0.31 12.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5
7 W 4 Metal Low-E Double Yes 0.54 0.31 48.0 ftz 1 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5
8 W 4 Metal Low-E Double Yes 0.54 0.31 12.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5
GARAGE
# FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 595 ft2 595 ftz 60.2 ft 9.3 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EqLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000414 2459.7 135.03 253.95 .3102 7
I
9/25/2017 9:55 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
I
1 � , •
FORM R405-2014
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump None HSPF:8.5 32.8 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 15 34.2 kBtu/hr 1026 cfm 0.85 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 70 gal 120 deg None �
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft�
DUCTS
/ —Supply— —Return— Air CFM 25 CFM25 HVAC#
\/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 453 ft� Main 113 ft2 Proposed Qn Main —cfm 136.0 cfm 0.06 0.60 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Coolin Jan Feb Mar A r Ma X Jun X Jul Au X Se Oct Nov ]Dec
Heatin9 �Jan �Feb f X�Mar f �Apr f �May E �Jun 4 �Jul ��Aug 4 �SeP f �Oct �Nov f X]Dec
Ventin Jan Feb [X Mar [X A r [ Ma [ Jun [ Jul Au [ Se [X Oct Nov [ J Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
c
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM ; 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MECHANICAL VENTILATION
Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System
None 0 0 0 1 -Electric Heat Pum 0% 1-Central Unit
9/25/2017 9:55 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4
P � • •
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
, , FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1904.00 ftZ
b.Frame-Wood,Adjacent R=11.0 364.00 ft
3. Number of units,if multiple family 1 c.N/A R= ftZ
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types Insulation Area z
a.Under Attic(Vented) R=30.0 2267.00 ft
6. Conditioned floor area(ftZ) 2267 b.N/A R= ftZ
7. Windows" Description Area c.N/A R= ft2
a. U-Factor Dbl,U=0.54 143.00 ftz 11.Ducts R ft2
a.Sup:Attic,Ret:Main,AH:Main 6 453
SHGC: SHGC=0.31
b. U-Factor Dbl,U=0.58 96.00 ftZ
SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: Dbl,U=0.56 38.00 ftZ a.Central Unit 34.2 SEER:15.00
SHGC: SHGC=0.28
d. U-Factor N/A ftz 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 32.8 HSPF:8.50
Area Weighted Average Overhang Depth: 4.206 ft.
Area Weighted Average SHGC• 0.309
8. Floor Types Insulation Area 14.Hot water systems
z a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 2267.00 ft EF:0.95
b.N/A R= ftZ
c.N/A R= ftz b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building . 4�1HE�7'A�
Construction through the above energy saving features which will be installed (or exceeded) o - F -
� _, p .
in this home before final inspection. Otherwise, a new EPL Display Card will be completed �<v`�,,;,°j�r =',�,.,'�'„�, .
i -- a� �`
based on installed Code com liant feat es. � r,r„��%;�.;'�A.,;;::��,� o
p W ..,,....:. �.
Builder Si nature: ..- Date: � ��-�5��'' ., �:�
, 9 10/10/17 �i�l_ �
# �.
Address of New Home: 6620 Pad n Wheel Street City/FL Zip: Zephyrhills, '4
FL 33541 .,�c �: �- u5-
oD y�,�'c� _
*Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support �
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
9/25/2017 9:56 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
7 � • •
Buildin Anal sis Job: 2268AB sf ADS
g Y Date: 9/2512017
Eni`ire House By: Dave
Bayonet Plumbing Heating and Cooling
8950 New York Ave,Hudson
� • ' • �
For: Lennar Homes
� - . • • �
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD (°F) 39 16
Latitude: 28°N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7
Dry bulb(°F) 31 91 Infiltration:
Daily range(°F) - 14 ( L ) Method Simplified
Wet bulb(°F) - 77 Construction quality Semi-tight
Wind speed(mph) 15.0 7.5 Fireplaces 0
•
Component Btuh/ftz Btuh % of load
Walls 5.6 9246 27.6 �as
Glazlllg 21.8 6006 17.9 wa�� nfilUaGon
Doors 23.5 466 1.4
Ceilings 1.3 2844 8.5
Floors 3.6 8064 24.1
Infiltration 1.7 3359 10.0
D ucts 3493 10.4
Piping 0 0 Fi°°�S
Humidification 0 0 Glazing
Ventilation 0 0 owe� Ceilings
Adjustments 0
Total 33476 100.0
• • •
Component Btuh/ft2 Btuh % of load
Walls 2'8 4599 17.6 walls Intemal Gains
Glazing 29.9 8221 31.5
Doors 18.4 365 1.4
Ceilings 1.7 3927 15.0
Floors 0 0 0
Infiltration 0.4 698 2.7 �ucts
D ucts 3927 15.0
Ventilation 0 0
Internal gains 4394 16.8 Glazing Infiitration
Blower 0 0
Adjustments 0 ceilings
Total 26130 100.0 Other
Latent Cooling Load= 3730 Btuh �
Overall U-value= 0.105 Btuh/ft2-°F
Data entries checked.
,� wri htsoft� 2017-Sep-2510:02:30
�� g Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1
...h CBA27UHE AH's\2268A8 sf ADS template 3ton.rup Calc=MJ8 Front Door faces: W
. � .
Pro ect Summaf�, Job: 2268AB sf ADS
J •' Date: 9/2512017
Entire House By: Dave
Bayonet Plumbing Heating and Cooling
8950 New York Ave,Hudson
� • ' • �
For: Lennar Homes
N otes:
� - • • �
Weather: Tampa InternationalAP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 °F Outside db 91 °F
Inside db 70 °F Inside db 75 °F
Design TD 39 °F Design TD 16 °F
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 29983 Btuh Structure 22203 Btuh
Ducts 3493 Btuh Ducts 3927 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
none
(none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 33476 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 26130 Btuh
Method simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 3009 Btuh
Ducts 721 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft2) 2267 2267 Equipment latent load 3730 Btuh
Volume(ft') 21250 21250 ,
Air changes/hour 0.22 0.11 Equipment Total Load (Sen+Lat) 29860 Btuh
Equiv.AVF (cfm) 78 39 Req. total capacity at 0.85 SHR 2.6 ton
Heating Equipment Summary Cooling Equipment Summary
Make Lennox Make Lennox
Trade 14HPX SERIES Trade 14HPX SERIES
Model 14HPX-036-230-21 Cond 14HPX-036-230-21
AHRI ref 10258589 Coil CBA27UHE-036-230*++TDR
AHRI ref 10258589
Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER
Heating input Sensible cooling 29580 Btuh
Heating output 32800 Btuh @ 47°F Latent cooling 5220 Btuh
Temperature rise 25 °F Total cooling 34800 Btuh
Actual air flow 1200 cfm Actual air flow 1200 cfm
Air flow factor 0.036 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.88
Capacity balance point= 33°F
Backup: n/a n/a
Input= 0 kW, Output= 0 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
c -�- wrightsoft' 2017-Sep-2510:02:30
�� Right-SuiteQtl Universal 2017 17.0.23 RSU05714 Page 1
...h CBA27UHE AH's\2268AB sf ADS template 3ton.rup Calc=MJ8 Front Door faces: W
�
� ,
Manual S Compliance Report Job: 2268AB sf ADS
Date: 9/2512017
Enfire House By: Dave
Bayonet Plumbing Heating and Cooling
8950 New York Ave,Hudson
� • ' • �
For: Lennar Homes
• • • • •
Design Conditions
Outdoor design DB: 91.3°F Sensible gain: 26130 Btuh Entering coil DB: 75.6°F
Outdoor design WB. 77.3°F Latent gain: 3730 Btuh Entering coil WB 62.8°F
Indoor design DB: 75.0°F Total gain: 29860 Btuh
Indoor RH� 50% Estimated airflow: 1200 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer• Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230*++TDR
Actual airflow: 1200 cfm
Sensible capacity: 29070 Btuh 111% of load
Latent capacity: 5130 Btuh 138% of load
Total capacity: 34200 Btuh 115% of load SHR: 85%
• • •
Design Conditions
Outdoor design DB: 30.8°F Heat loss: 33476 Btuh Entering coil DB. 69.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data atActual Design Conditions
Equipment type: Split ASHP
Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230"++TDR
Actual airflow: 1200 cfm
Output capacity: 32800 Btuh 98°/a of load Capacity balance: 33 °F
Supplemental heat required: 676 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: n/a Model: n/a+n/a
Actual airflow� 1200 cfm
Output capacity� 0 kW 0% of load Temp. rise: 0 °F
Meets are all requirements of ACCA Manual S.
2017-Se 2510:02:30
�� wrightsoft� Right-Suite�Universal 2017 17.0.23 RSU05714 � Page 1
...h CBA27UHE AH's\2268AB sf ADS template 3ton.rup Calc=MJ8 Front Door faces: W
y�,'�l"J - '� .'\� . Y .,tJ' p�.- •r� a -
�� 5 � U �. Q�-f�� +�Q '�' .���
fj1 � �e', °.�`7� '�.� � O. � � .� 'ti' •--'-"--�_ �_ � 7-
Gh 1 � e,• . .E`a�. Q ��-------- � `.r
+� t ' h,'� t � � � � ` � � (1�` '�j'�
r,� ;i 7, � cb �` _ �Q��,:, hJ .�,'r �Q '
ar �OT08.S0 � �' ,�V '�`t.,• `Q,,,`�` ;a..'��� � d- � .
��,. •' PAD=107.8 �- YO '' `� ' ,�D
~,o- TYP,E 8�.. � O �'O �` .,��� pfk'
' +"y' '� ' � ,r'" ?c •f- ��O '. `�`� �� •r'�
• r�,ao'� � " �• � �4 �, o
Z�� l3' Y �'! ' Lq, k 7 . /'/ RO .�i ♦ '�� ♦ �Q,J� r��`, , ��}
a. ` '�D' r'y ^ / - _ _ �"�� 1'V i
o� - ��FF=108:7,0' i _ _ � -.�,� TO��: Q•� ,�0�' •
�;, �7. : LflT 1 '��'. � � p ��` �'� s
_ � PAD=���_�'��. ,i ,�n �.1 ,�.
e�.M� ' .ss � TYP �B -�-� � ,�o aQ ; � '•.c�bc
� � �' ' ` p, �� o i �� � '- Q `�` `� ��D�
.�•.Eu y�' - � � .p . o o , ...o• � �p`• . �0�3' �. ; '
.�, . � ��.,� � 4 �
7.,.f, ;,,.� � �- �, .�` 6,�'�n�, ,� \ � qQ �, o�.
�yw3 : �.r� � .c,o.9,� 8. -;.� �r� � 0 9&.' . •+1� , `��1' 1 f0 �Q ` � 10�.
,� -.� �e 1�.1,�� Y� � '� .� �F�=1�8.9Q ���\ � Q }.Z .� f- '•,
' ,��•'�_` ,�.-... LOT, t 6 ^� °` _ . ,'�0 LOT 5 -�-'� ,,��. 18 �� ��, �'�
,�,' ,� -PAD-t08.2. � �� PAD-108:2 ` � � �� r �
,_ ',��7YP.,;E�; 'Q"={�' i �1 � T'�@£�q _'` 8 �� a �\ �Gj
V •' '�; ��t. / - � �. _ x. . �1� C
.� r:'. - , _ -!- � _ \ � • -,.r
1�_� '. �'�:�i-��' � � ' � � .�1
'��'` �- 1.� � _��'" �� $� \�. 4` h �� ��0�'0. `� .�.�.'�� c
yI ,_i O K�p'i y FF=�os.2o 0�' -�'�d � �O�o `, � O-
FF=10�U �. -�- "�1-1 _,� � Q • O �- T�
j.Ort'"15 :.�t��"r° I !�� P Do 1 6.5 • .1 •
-•PAD-108.3 �.: !� TYPE A - " - -- - -- -F LQl'94 O `� t0 8 96�' ��04\� ��� `,
D 7'YP E B r ��� �' i ,�O" 1p pAD=1Q '1_ � �p'l�
0• ' ' °�j�S -- ---- �. o `�"TYeER�� Fy P � roc
���z•i�• ��1 . �.�" -'`� +,� ' �f�.-/1� Ogj- � 4`{?• ' �`tb. , nl� �� pQ L],
,r '� _i-1 -f��� � 'r �`� � -.d;` C� .,��J`"� -��. -
-``� ~^` °t, ! ,� �r �� K.Q� - -}�� '� a.p•�
�+� a � , � , -- •�e' �,
• h � ` ^ � \
: FF=109�.2D '° i�'• - �r � FFLOT 97� \,.! �, 07 63,.
' LOT 14' Q4 ��
� PAD=108:5 t �jC L1��y PqD=108.9 � � `�r�
,r TYPE� B i �� • � � i ^yt''rPE A ��'p `b
i-1 � �
e $��� r -,.� � FF=109.90 •Z o� g. �o
`�, � P: '1 Lfl'f 3 � "c,1 0� `' '�
� � , ,�. - Q . �,�, PAD=109.2 � � � $� a��. ,o •�.
�5 , r-� ^ �.� 1 �O$. �� 'TYPE A -�- _�.^� . '-�- . ���' 'F`'� �
FF=109.b0 `� �i ' � � � `` ,S�R � ,t � �.
' , �e LbT 13 � t r1 . ., �� ` '� ^ �`� r
PAD=108.7 �iti �s FFa11 ���" . J„'t�� p`b' �� '1 �� '"` � •��J ,�
'a's ,TYPE B ,r1� � , L ��' j'� ,�QQ�• `b 6' .�Z„ .•'�`-h� ���~`O� O �'' �
� �'1 � i PAD� 09.3 . Y. ��Q ��• •" �, � O�. �,� .1 ,
� � ..� � : + TYRE A �as.3 -�� '�, � =F'� �
e'. � � y� �~` �'� y,� � `FF=109.7Q O �`� t�
°�" � �`sr1�n�.cn � , t� 1.. � - �:1� n /\ .5 , FF-109^90 � i ll'i' 1 �'1 �f� . '
« .
SKETCH ONLY SEC. 05 , TWP. 26 S, RNG. 21 E.
' PLOT P�.,AN � NOT A BOUNDARY SURVEY
' LOT 7, BLOCK 3 BEARING gASIS:
SILVERADO RANCH SUBDIVISION NORTH BOUNDARY OF SE� OF OS-26-21 BEING N 89'25'01" E
PHASES Z, 3 8C g- � THIS SURVEY IS SUBJECT TO ANY FACTS THAT
PASCO COUNTY, FLORIDA. • Mnr BE DISCLOSED BY A FULL AND ACCURATE
TITLE SEARCH. AL50 SUBJECT TO SETBACKS,
ON LOTAREACALCULATIONS EASEMENTS AND RESTRICTIONS OF RECORD.
LOT = 9859•'�a SQ. FT. rao UNDERGROUND FObTER, STEM WALL, AND
LIVING AREA =_226� SQ. FT. �� UNDERGROUND UTILITIES ARE NOT LOCATED OR
ENTRY =�3 SQ. FT. SHOWN.
GARAGE = 585 SQ. FT. �
COVERED LANAI = 153 SQ. FT. w DO NOT SCALE THIS PRINT. DIMENSIONS AND
PAT10 =�A SQ. FT. ¢ NOTES TAKE PREFERENCE.
CONC. DRIVE = 615 SQ. FT. �
A/C & CONC PAD = 9 SQ. FT. N DESCRIPl10N NOT CONTAINING PLAT BOOK AND
PRIVATE SIDEWALK =4� SQ. FT. PAGE INDICATES THAT PLAT IS IN
IMPERVIOUS =37 % PRELIMINARY STAGE AND IS SUBJECT TO
= 3692 SQ. FT. p�(p�
CHANGE AND/OR REVISION.
SOD = 6197 SQ• �T• CERTAIN DATA SHOWN HEREON BASED ON
ENGINEERING PLANS PROVIDED BY CLIENT_
OFF LOT AREA CALCULATIONS
RIGHT OF WAY = 1954_03 SQ. FT. STRUCTURE TIES SHOWN HEREON DENOTES
DRIVE APRON = 350 SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDAl10N
PUBLIC SIDEWALK = 531 SQ. FT. ,j? TO PROPERTY LINE.
SOD =_ 1073 SQ. FT.
* = 10' U'IILITY EASEMENT
TOYALS '-•
AREA =_ ��843•5� sQ. FT. PREL[MINARYDRAWING:
DRIVEWAY = 965 SQ. FT. �-./o THIS PLAN IS FOR PERMITTING PURPOSES
SIDEWALK = 571 SQ. FT. ' �' ONLY, NOT FOR CONSTRUCTION. VERIFY
SOD = 7270 SQ. FT. / `.ij� ALL DIMENSIONS BEFORE ANY CONSTRUCTION.
LEGEIdD:
:'��oo "l-�= PROPOSED DRAINAGE FLOW
+ � (00.00) = PROPOSED GRADE
�•^•�1���2 BLOCK63 E-00.00 = EXISTING GRADE
W .s� �` S �
_a
� I �r�',�°' • 2��5 35., e
� %:o:�. .,� ��7 /
� ,� .,N 2g.
J /
W� 2�.$Q' �O. � ool
U ^ 1�p9-
W � S 82'27'a4•E -
� ' 66���..
2 38.
2� :.. *' �--••-... � 30.78'� - .
� w �' � n.., Z F \
¢I •��.• � �'� '..�r5.54' � � x ¢ �
� c,. " �t p.. .: 'Y ' 4 ' (7 �
� � o` ;:U �• �I":.,'� ;- Oro�lY n"> 3 O
� : o. ' : o• •w.2�-61••'�=._�' U1tlj N>'W -y ro� c0
�� :n�..;•�• ,y:.: ' .. . . o p N�U' Op �� -
Q • - N:.� � � � � a m�4 Jm �^ �
Q . ... `�;;""., ;N: a � " J '
� LOT 3
� .?�� `•'�w� N BLOCK 3
...2�:67 ... O
I I • ^
�. � 31.79' O
.` � I .a o. _ .. �
I / "N `°.
+, I � ��� r�o9
�--/' S 86"22'23" W 118.14' •�oJ
o.00' �'o�
a 'ssJ 1
rn IM
� :•.'I LOT B
� BLOCK 3 NOTES:
o LOT GRADING TYPE = A
N
� PROPOSED PAD ELEVATION = 108.9'
O1 FRONT SET BACK = 20'
rn �'�1 SIDE SET BACK = 7.5'
o, REAR SETBACK = 15'
3
v
� DESCI�IPTlOh6: PROI�O�ED:
Y LOT 7, BLOCK 3, N1AP OR PIAT ENTITLED "SILVERADO RANCH LOWEST FLOOR ELEVATIONS:
m SUBDIVISION PHASES 2, 3 & 4", AS RECORDED IN PLAT LIVING AREA: 109.60'
� BOOK 73, PAGES 59 THROUGH 65, OF THE PUBLIC RECORDS GARAGE AREA:
'� OF PASCO COUNTY, FLORIDA. ELEVATIONS REFERENCED TO
� cuRVE RADIUS nRc CHORD BEARING DELTA NORTH AMERICAN VERTICAL
= co z�zoo• �iz.ea� �ii.so� N 30'07'za�• E 23'78�za�� DATUM OF 1988. MEAN SEA
� ctas z��.00' �os.ia� 104.51' N 0735'so^ E zraa'sz^ LEVEL= 00_00 FT.
z
�
g APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL N0. 120230 0455 D EFFECTIVE DATE: 09/30/1992
� LEGEND:
j (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, r= CENTERLINE, A�C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
� CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, �E/P="EDGE`OF,PAVEMENT, ESM'T= EASEMENT,
=F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FlP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND-NAIL & DISK, FPP= FOUND PINCHED
� PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, FCP= �E�4MANENT CONTROL- POINT, PRM= PERMANENT
Q REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NA!L 8c DISk;�76M= TEMPORARY BENCHMARK,
� U P= UTILITY POLE, W F= WOOD FENCE. R = RADIAL - "
� JOHN R.BEACH&ASSOCIATES,INC. Drawn By. SMS Square Feet: � 9889.48 t � LENNAR HOMES
w + SURVEYORS AND MAPPERS Checked By. - � _ �
� � 911 WEST ST. PETERSBURG DRIVE JRB �-� -.%}
in ONE OLDSMAR, FLORIDA 34677 _ -
� WAY (813) 854-1276 FAX (813) 855-8370 Scale: �^=30' -
0
� NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 9 19 17 ACS � V
'v THE ORIGINAL RAISED SEAL OF A FLORIDA OHN BEACH - ATE
� LICENSED SURVEYOR AND MAPPER FLORIDA G. LAND SURVEYOR No. 2984 LB#4493
�
/ Revisions:
�
% " 5335 - 8TH STREET
(813)780-0020 �
- � CERTIFICATE OF OCCUPANCY �
Address: 6620 PADEN WHEEL ST Owner: LENNAR HOMES LLC
ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200
Subdiv: SILVERADO TAMPA, FL. 33607-4099
Parcel: 05-26-21-0070-00300-0070 ' Work Type: 101-NEW CONST/SFR
Construction Type: NOT APPLICABLE ❑ Sprinklers
Use Classification: NOT APPLICABLE
Permit Number: 19001
Date: 4/09/2018
ISS�ED BY: BUI�f�O CIAL :
WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE
GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE