Loading...
HomeMy WebLinkAbout17-19065 CITY OF ZEPHYRHILLS 5335-8TH STREET • • � (si3)�so-oozo � 19065 BUILDING PEitMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION.INFORMATION Permit#:19065 Issued: 11/29/2017 Address: 3137 MOULDEN HOLLOW DR Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Tawnship: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 378,391.35 Total Fees: 15,023.47 Subdivision: HIDDEN RIVER Amount Paid: 15,023.47 Date Paid: 11/29/2017 Parcel Number: 24-26-21-0090-00000-0410 ' CONTRACTOR INFORMATION - OWNER IIdFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 WEST CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607 Phone: (813)574-5743 Lic: Phone: Work Desc: CONSTRUCT SINGLE FAMILY 3,359 SQ FT APPLICATION FEES PLUMBING FEE 198.75 SEWER CONNECTION RESIDEN" 2,010.00 ELECTRICAL FEE 298.13 WATER CONNECTION RESIDENI 641.00 MECHANICAL FEE 139.13 SCHOOL IMPACT FEE-sfd 1% 48.28 SCHOOL IMPACT FEE-sfd100°/a 4,828.00 TRAFFIC IMPACT FEE 1°/a 36.32 TRAFFIC IMPACT FEE 99% 3,595.68 BUILDING FEE 1,431.49 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE � 273.00 PUBLIC SAF TY 5% 26.35 PARK FEES SF 769.56 ��Y ' �� ' V �,'W��� /�/� r•� _ �,U�� �� � � Ins ections Re uired ' FOOTER 2ND ROUGH PLUMB MIS INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.8A (2)(c)the local government shall impose a fee of four times the amount of the fee irr�posed for the initial inspection or first reinspection,whichever is g�eater,for each such subsequent reinspection.REINSPECTION FEE�: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORS SI TURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER - � I � - < � . . � Pasco couNnr Cvv���'-� DEVELQpMENT SERVICES P V � 1 t".,r i 8731 Citizens Drive Date:2/14/20i 8 COUNTY FLORIDA New Part Richey,FL 34654 farr.ia�r.v.-�.Vtarc�:vr Pr.nr.:�C, 727-847-2411 *� ��� � ���IYi�� �'� ' Receipt#: 1737960 FEE DESCRIPTION ACCOUNT CODE UAfITS INVOICE# FEE AMOUfYT PAID RECEIPT# DATE Impacf Fee Residential Solid 24503100-329010 6.00 1320011 $328.44 $328.44 1737960 2l14/18 Waste Single Family ' TOTALS: �328.44 a3Z8.44 Receiot# Paid gv Check CC u # Cashier ID Workstatfon f�eceiot Date Amt Paid 1737960 Cheok 11890 54� BCCCP06W 02/14/2018 $328.44 Total Payments: �328.44 Pavor Address Phoae Lennar Homes 4600 W Cypress Street, 813-5745745 Suite 200 Tampa, FL 33607 Comments• �I City ofZephyrhills Permit#18979/18983/19065/19066/19067/19068. Hidden River Phase 1A PB 74 Pg101 Lot41,105,106,107. and Silverado Ranch Phase 2,3,4,PB 73, Pg 59, Block 03,Lot 93 and Block 04, Lot 03. Whlle ynu wlll be paying your blll wlth Pasco county Uevelopment 50rvlrBs,the fu11�maunt ot the credlt caM ar e-check fees,NQT shown eboye,ts collected hy Flrst Billing payment services. MyReports/reports//PROpUCTION/PASCO/ReceiptPOS V5,rpt 2/14/2018 Page 1 of 1 � � Jacquelin� Bog�s i From: FATHOM <support@gwfathom.zendesk.com> Sent: Wednesday, February 14, 2018 10:00 AM I To: Jacqueline Boges �, Subject: [Request received] 3137 Moulden Hollow Dr water/sewer �� ##- Please type your reply above this line -## Hello ]acqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://gwfathom.zendesk.com/hc/requests/195114 � � ; Jacqueline Boges �-- , Feb 14, 8.00 AM MST New service 3137 Moulden Hollow Dr need water, sewer and water 3/4 meter this order was suppose to be done in November 2017 and it was so I am asking could we have this order rush out to site sorry about the last minute but would appreciate anything you could do to get this meter out This email is a service from FATHOM. � 1 i _ _ r , ���..�z; � � ;��;�'��4fl�a`�.: ���. ��,�,�. ;,.«..;t,; �-,; -,�'�n.,i� ti:. �w��_�W.._ .rw. City of Zephyrhills , BUILDING PLAN REVIEW CONiMENTS Contractar/Fiomeowner: c1Gt�-r � Date Received: a-- �� � � 3 � 3� �o�j�n � 1/��J ��. site: ; 2 Pernut Type: �! l� � �2 9p Approved wino com�nents:❑ Appraved wlthe below cc�mmen#s: Denied wlthe below co�unents: ❑ ��C >lrL,2 P � � i This comment sheet shall be icept with the permit and/or plans. � �����7� Kalvi.n Swit —Plans Examiner Date Cantrac r and/or Homeowner {Req ed when camments are presen#} I IIIIII IIIII IIIII IIIII IIIII Iilll Iltli IIIII Ilill iilll IIII IIII - • 2017182063 � Rcpt:1909816 Recp 10.00 � DS: 0.00 IT: 0.00 - ' il/16/2017 K. R. , Dpty Clerk - " PRULA S 0'NEIL;Ph D PRSCO CLERK & COMPTROLLE " 110R BK01����m PG 1��� Permit No. Parcel ID No 24-26-21-0060-00000-0410 - NOTICE QF COMMENCEMENT State of Florida County ot PaSCO THE UNDERSIGNED hereby gives notice that improvement will tie made to certain real property,and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: . 1. Description of Property: Legal HIDDEN RIVER PHASE ONE A PB 74 PG 101 LOT 49 streetAddress: 3137.MOuldell HOIIOW D�Ive Zephryhills FL 33540 " 2. General Description.of Improvement Singl'e Family Residence/Pool/Screen Enclosure/Fence 3. - Owner Information: Lennar Homes, LLC. Name . 4600 W Cypress St. Ste 200 Tampa . FL. 33607 Address ' , City State ' Inte�est in Property� Name of Fee Simple Titleholder . N�A _ - (If other than owner) , Address City State ` a. contractor. Lennar Homes, LLC - Name 4600 W Cypress St,.Ste 200 Tampa FL, 33607 � Address City State Contractor's Telephone No.. 813 574.5700 5. Surety� •. N/P� Name . Address- City State Amount of sond: $ Telephone No.. ' s. �ender: IV/A Name Address City State Lender's Telephone No.: . 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: , Lennar Homes LLC . Name - - 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address , City State , Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A � of to receive a copy of the Lienor's Notice as provided.in Section 713.13(1)(b),Florida Statutes. , Telephone Number of Person or Entity Designated by Owner� � 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT � , ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN � RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT ' - WITH Y-0UR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA _ �� COUNTY OF PINELLAS SignatUre of Owner or Owner's Authorized Officer/Director/PartneNManager . Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 6 day of March ,�0/� ,by ' - Steve Robert Smith as VICe President (type of authorit r,trustee,attorney in fact)for �� Lenna�Homes, LLC (riame of pa eh hom instrument was executed). - Personally Known�OR Produced Identification❑ Notary Sig rt�e —� Type of Identification Produced' � Name(Pr� �SS olleran . �Verification pursuant to Section 92.525, Florida 5tatute5. Under penalties of perjury, I declare that I have read the foregoing and that.the facts stated in it are#rue to the besf of my`linowled'ge and belief. , . ,_ � ��,,; � ' .. � - ;��;=ELISSAM.HOLLERAN Signature of Natural Person Signing Above - - - _�;- ;,:Cemmlesion�FF885831 � � o'=Explres June 6,2020, wpdata/bcs/bcsformt! �''�'��, BondodThru7m Folnlfuunncot60 , r. a�-roio , ill _ � - �������A4P �����T�0 CERT�IF�YTH T�uH�FOREGOWG�IS A ,�QP e � ' ° � TWIS 1S �r' a.� ��� �'RUE AN�C�RRECT COPY OF THE DOCUMENT � ' ��.:.. ° CN FfLC 0'R OF PUBLIC RECORD IN THIS OFFIC� -. }� V'UITNE�S,MY� HAND AND OF ICIAL SEALTHI�� � �K •� � L'(.� 2 �n Godtive�,-usr e f �J pAY QF " °�`'' � pq�`�.�'N�IL,CLERK COMPTROLLER � , � � ��� DEPUT�CLERK � 3b�� � 8Y �r`�������`�� � , , - � ,- . , � PASCt3 �t�►l)tVTY, �=Lt�RIDA , , � . Permtt No. ��� Date Permitte /t- I�Z 17 Builder Name/�wner Name I�Yt/lQ.r ��GM'Y�� ��C°� Controt#' County ParceI No. .Z�-?,_,jo-2(-��l(o�-.(�t�QO-C}�/l0 SubCliv: ��t�i�Pn �[ue� Address/�ocation � (�'?l�p GC,1 �P.r1.. t�t�tlDGt7 �� � ClassificationtType of Use ��p -�,,yu��-�o�_ TRANSPORTATION fMPACT FEE Rate: Sq.Ft Unit: � �J� Exempt �Yes � No Haw Determined � tmpaat Fee Amount $. �, ��.� Zone Na. TRZ: SCHOOL INIPACT FEE I Account (056) Singfe-Famify Detached House Amount $ ��'7�, 2� (057) Mobile Home (058) Other Residentiat 123} Coitectton Fee Exempt []Yes ❑No How petermined PARKS AND RECREt�TtON FEE � Land Accaunt Land Credit Land 7ota1 ' � Recreation Account Recreation Credit -Rec�eation Total Zone TOTA�AMt7UNT $ '7(Q�S�, Exempt [�Yes � Na How Determined � � L{BRAR.Y FEE � Land Account �.and Credit Land Tpta) � � Facility Account Faciltty Credit Facitity Total ' Exempt [�Yes � No Haw Determined Tata{Amaunt � '"f RESOURCE FEE E,RU TOTAL AMOUNT � � Prepared By Checked By NO CERTiFICATE OF OCCUPANCY W{LL BE{SSUED i3R FINAf..INSPECTIO�1 PERF.ORMED UNT1L THE TC?TAL AMOUMi'S LiSTED HAVB . BEEN PAID AND RECEIP7ED FOR BY A CENTRAL PERMITFING OFFICE QF PASCO COUNTY Acknowledgamsnk below does not Imp{y acceptance of concurrence,but simply recelpt of a copy of this form,placing 'I the buiiding psrmlt owner on notice af this assessment and fhQ conditlons of payment ior same. i . I i � DATE - RECEIVED BY . � '', RECEIPT NO. DATE BY � , t � .�..._..s. _- ��-- - s�3-7sa-aoza City of Zephyrhills Permit Application Fax-813-780-Od21 ' ' . Building Department Date Received Phone Contact for Permitting 813 363 _ 2897 I 1 1 i i ! I 1 1 I I 1 1 Owner's Name �ennar Hames,LLC Owner Phone Number 813.574.5700 Owner's Address ����W.Cypress St.Ste.204,Tampa,FL 33b07 Owner Phone Number �^ � �,, _ Fee Slmple Titleholder Name N�A � Ownar Phane Numlier �' � Fee Simple TitlehaEder Address N!A � JOBADDFtESS 3137 Moulden Holfow Drive _ - � ,. }__r�,T# 0410 Hidden River Phase One A� 24-26-21-006G:�C.�<<i�,�=0410 � SUBDIVISION PARCEL.ID# (OBTAtNED FROM FAOPERTY TAX NOTiCE} WORK PROPOSED ��./ �� NEW CONSTR 8 ADD/ALT � SIGN � � DEMOLISH � IhlSTALI REPAIR PROPOSED USE � SFR Q COMM � OTHER TYPE OF GQNSTRUCTIt,}N �f BLCiCK Q FRR3ViE � STEEL � �. / DESCRIPTION OF WORK Single Pamily Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF 3359� SQ FOOTAGE 290� HEIGMT � StOrY� �BUILDING $ �� `,y� VALUATION OF TOTAL CONSTRUCTION f u�/ �ELECTRICAL �� � PROGRESS ENERGY � W.R.E.C. '� ` AMP SERVICE -� �PLUM8ING ($ � �� �' � ��MECHANICAL $ VAL.UAT(ON OF MECHANICAL INSTALLATION �ir} � ��� �GAS � RQOFING Q SPEGIALTY � OTHER FINISHED FLOCIR ELEVATIONS �..� FL04D ZONE AREA �YES nV0 L...� . . . . . . . . . . . . . . . . ._. ._._. . ._. . . . . . . ._. . . . . . � BUILDER � COMPANY Lennar Homes,LLC SIGNATURE REGISTERER Y/ N FEE CURRE� Y/N Address 460Q W.C�press SC.Ste.200,Tampa,FL 33607 License# CGC1518166 �� ELECTRtCiAN COMPANY Edmonsan E(ectric, �tlC. SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Address �fl34 Skipper R ad,Tampa, FL,33613 �icense# EC1300540$ _—� Pt�UM8EF2 � COMAANY gayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Address P.O. Bax 5308 Bayonet, FL 34674-5308 License# CFC042998 � NtECHANICAL '' GpyNp,q�y Bayanet P1t�mbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Address PA• Box 530$, B�yonet, FL 34674-5$Q$ �icense# CAC058062 —� OTHER GOtU1PA(+!Y SIGNATURE �~ REGISTERED Y/ N FEE CURRE� Y/N Address 4211 Shoai ' e Blvd, Spring.Nill, FL 34607 �Icense# CCC057991 � IIIIIIIIIIIIIIIIIIMIIIIIIIIIIIIIMIIIIIIIIIIIIIIIIIIIYI '1111111L11111 RESiQEN7lAL Attach(2}P(ot Pians;(2}sets of Buiiding Pians;(3)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(14}warking days after submitta(date. Required onsite,Construction P1ans,Stormwater Pians w/Silt Fence instailed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMIVlEl2G1AL Attach(2}cornplete sets of Buildi�g Pians plus a Life Safety Page;{1}set of Energy Forms.R-O-W Petmit far new construcfion. Minimum ten(10}working days afFer submiftal date. Required onsite,Construction P(ans,Stormwater Plans w/Silt Fenee instailed, Sanitary Facilities&1 dumpster Site Work Permit for all new projects.All commercial requirements must meet compliance SlGN PERMlT Attach{2}sets of Enginaered Plans. "'�"PROPERTY SURVEY required for aii NEW construction. Y. ■ • • ■ • ■ ■ • • ■ • ■ ■ • �__y_.■ ■ ■..■ • • ■ Y • ■ • ■ ■ • ■ • • ■ • ■ ■ • ■ Y • ■ • ■ • � ■ • • ■ ■ • ■ Y • pirectfons: Fili out application campletely Owner&Contractor sign back of application,notarized (f over$254Q,a Notice af Gommencement ts required. (AtG upgrades over$754Q) �" Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER TtlE C�UNTER PERNlI7TtMG {copy of contract required} Reroofs if shingles Sewers Service Upgrades AJC Fences(P(ot/Survey/Footage} Driveways-Not over Gounter if an publlc roadways..needs ROW 1 - NOT(GE C3F DEED RESTRIGTICINS: The undersigned understands that#his permit may be subject to"deed",restrictions" which may be more restr.ictive than County regu(ations. The undersigned assumes responsibility for compiiance wi#h any applicable deed resfrictions. � . , UNLICENSEL? GONTRACTORS AND CONTRACTOR RESPONSIBlUTIES: If the owner has hired a confiracto� or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the'owner and contractor may be cited for a misdemeano� violation under state law. If the awner or intended cantractor are uncertain as fo rrvhat Iicensing requirements may appiy for the intended work, they are advised to contact the Pasco Couniy Building Inspection Division—Lieensing Section at 727-847- 8009. Furthermore, if the awner-has hired a contractor or contractars, he is advised to have the contractor(s) sign portions of the "contracfor Black" of-this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication�that he is not praperly (icensed and is not entitled ta permitting privileges in Pasco County. ` ' � TRANSPOR7ATION IMPAC7NTlL17'IES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportatian Impact Fees and Recourse Recovery Fees may apply ta fihe construction of new bttildings, change of use in existing buildings,,or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees„as may be due, will be identified at the time of permitting. It is further understood fhat Transportation �impact Fees and Resource Recovery Fees must be paid prior to _ receiving a"certificate of occupancy" or firia! pawer release. Ifi the projeck does nat invalve a certificate of occupancy or final pawer release, the fses must be paid prior to perrr►it issuance. Furthermare, if Pasco Gounty WaterfSewer impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. .--,� CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as.amended): lf valuation of work is$2,500.00 or more, I - certify that 1, the applicant, haue been provided with,a capy of the "Florida Construction Lien Law=Homeowner's � , Protection Guide"•prepared by the Florida Department of Rgriculfure and Consumer Affairs. lf the,applican# is sameone other than the'"owner", ! certify that ! have abtained a copy of the above clescribed 'document and promise in gaad faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWI�ER'S AFFIDAVIT: I cer#ify that all the information in this applicatian is accurate and that all wark will be dane in campliance wifh afl applicable laws regulating construction, zoning and (and deve(opment. Application is hereby made to obtain a permit to c!o work and installation as indicated. 1 certif}r #hat na work ar instaliafion has commenced prior to issuance of a permit and that all wark will be performed ta meet standards of all lavus regulating construction, County and City codes, zoning regulations, and land development regulatians in the jurisdiction, ! also certifiy that ( understand that the regulations of other gavernment agencies may apply to the intended work, and that it is my respansibility to identify what actions i rnust take to be in compliance. Such agencies inciude but are not limited to: - Department of Enviranmental Protection-Cypress Bayheads, Wetland�Areas and Enviranmental(y Sensi#ive Lands,WaterlWastewater Treatment. - Sauthwest Florida Water Management District-Wells, Cypress Bayheads, UVetland Rreas, Altering Ul/atercaurses. � - Army Carps of Engineers-Seawalls, pocks, Navigable,Waterways. ' - Department of Health & Rehabilitative Services/Environmental Health Unit-Welis, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestas abatement. , - Federal Aviation Authority-Runways. � i understand that the following.restrictions app(y to the use of fill: - llse af fill is not allowed in Flaod Zone"V" unless expressly permitted, - If the fill materia! is ta be used irt Flood Zone "A", ifi is understaad that a drainage plan addressing a "cornpensating volume° will be submitted at time of permitting which is prepared by a professiona! engineer , licensed by fhe State of Florida. ' - (f the fill materia(. is.to be used in �(ood Zone "A" in connection with a permitted building using stem wall construction, 1 cer�ify that fil!will be used anly to fill the area within the stem wa(fi. - !f fi!! material is to be used in any area, 1 certif}r that use of such fill �wil! not adversely afFect adjacent , properties. !f use of filf is found to adversely�affect adjacent properties, the owner may be cited for violating the conditians of fihe building permit issued under the attached permit.application, for lots less than one (1� acre which are elevated by fi(I, an engineered drainage plan is required. !f 1 am the AGEfVT FOR THE �WNER, ( promise in goad,faith to inform the owner af the permitting conditions set forth in this affidavit prior ta commencing construction. I understand that a separate perrn9t may be required for electrical work, plumbing, signs, wel(s, poals, air conditioning, gas, or other installations not specifica(ky,included in the application. A permit issued shall be construed to be a license to proceed with the wark and no#as authority to vialate, cance(, alter, or set'aside any pravisions of tiie technical codes, nor sha(( issuance of a permi# prevent the Building Official from thereafter reqetiring a correction of errors in p(ans, construction or violatians of any codes. Every.permit issued shali become invalid , unlsss the wark autharized by such perrrtit is commenced within six months of permit issuance, or if work authorized by the.permit is suspended or abandoned far a period of six(6) months after the time the work is.commertced. An e�ctension may be requested, in writing, firom the Building Official for a periad not to exceed ninety (90).days and wil! demonstrate jusfifiable cause for#he extension. If wark ceases for ninety(90} consecutive days, the job is cansidered abandoned. 1f1fARNING Tt� OWNER: YOUR FAILURE 1'U RECORD .A NOTICE t3F CONtMENCEMENT MAY�RESULT tN Y{3UR PAYING,TWICE FOR lMPROVEMENTS TQ YOUR PRt?PERTY. IF YOU 1NTEND 70 t�BTA1N FlNANGING; CON�Ul.7' WITM YOUR LENDER OR AN TTORNEY BEFQRE RECORDlNG YOUR NOTICE OF COMMENCEMENT. FLdR1Dfi,JURAT(F.S.117.03} � OWNER OR AGENT CONTRACTOR � _ Subscribed and swom to(or,afflrme8 before me this � Subscribed and sworn#o(ar affirme before me this u°-U�i`!!. by.�au Sweeney - - Q6:oG�-+z _ by Pa Sweeney _ –-- -- __ ._ - Who is/are personallV known to me or Who is/are personallv known to me or as identification. as idenfiftcatian. ,�..'.�"—� �, Notary Public � �-- Notary Pub(ic Comrrtission No. FF98537 ' Commfssion Na. .�F9$537 ' Elissa M.Holleran ' Elissa M.Holleran ' ' Name of Notarv tvped,printed or stamped. Name of Notary typed,printed or stamped '�'� - . ...�11��R`�.,�i����+Ml� �1�i�4�,Mh�t&�dNl� ' y��mm�+r.�an��R�a�ae�' ,y �ttstt�tflatU,���b��'�' r�!�pM��l�t�di�D��J i_P��4`kBJlll������� �' � • �d�l'�a°I'�€�dn�a,eae�#dt'�!! . ;I � . B�sdI��YPJ'G�yFatn'I�tApr�61ILR1i�l� � - - _ � A � - , , Lennar Homes-3137 Moulden Hollow Dr 3,359 sq�ft � �� ���QS� o umn SQ. FEET PRICE MAIN OR LIVING: 3,359 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ _ VALUATION $ 378,391.35 FEE SHEET $ 1,325.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 ' BUILDING: $ 1,431.50 ELECTRICAL: $ 298.13 PLUMBING: $ 198.75 MECHANICAL: $ 139.13 SUB-TOTAL $ 2,067.50 TOTAL $ 2,067.50 SEWER: $ 2,010.00 WATER: $ 641.00 IRRIGATION: $ - TOTAL: $ 2,651.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,745.63 Pi4RK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 ' 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 15,023.47 � , , t. _ _7 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential PerFormance Method Project Name: 2889A1 sf ADS 2017 Builder Name: Lennar Homes 0041 street: 3137 Moulden Hollow Drive Permit Office: �i�o��ephyrhills City,State,Zip: ,FL, Permit Number: D Owner. Lennar Homes Jurisdiction: C14C00 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2754.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 1308.70 ftz b.Frame-Wood,Exterior R=11.0 1114.00 ft� 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 331.50 ftz 4. Number of Bedrooms 5 d•N�p` R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2313.0 sqft.) Insulation Area � a.Under Attic(Vented) R=30.0 2173.00 ft 6. Conditioned floor area above grade(ftz) 2896 b.Knee Wall(Vented) R=30.0 140.00 ft2 Conditioned floor area below grade(ftz) 0 c.N/A R= ftz 11.Ducts R ft2 7. Windows(193.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 358 a. U-Factor: Dbl,U=0.54 96.00 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 221 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 64.00 ftZ 12-Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 b.Central Unit 18.0 SEER:16.00 c. U-Factor: Dbl,U=0.56 33.33 ftz SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a.Electric Heat Pump 21.8 HSPF:8.50 SHGC: b.Electric Heat Pump 17.5 HSPF:8.50 Area Weighted Average Overhang Depth: 1.172 ft. Area Weighted Average SHGC: 0.302 14.Hot water systems a.Electric Cap:40 gallons 8. FloorTypes (2902.0 sqft.) Insulation Area EF 0.950 a.Slab-On-Grade Edge Insulation R=0.0 1793.00 ftZ b. Conservation features b.Floor Over Other Space R=0.0 672.00 ftz None c.other(see details) R= 437.00 ftz 15.Credits Pstat Glass/Floor Area: 0.067 Total Proposed Modified Loads: 84.94 pASS Total Baseline Loads: 85.63 � I hereby certify that the plans and specifications covered by Review of the plans and _' cT�E���"� -. Y r""- �� � this calculation are in compliance with the Florida Energy specifipations covered by this ,�'�3 _�,,�0�_ :; Code. calculation indicates compliance � .���,,;''' °=,�a`.��_��.rc+. ., . a.� '� /-/ with the Florida Energy Code. ��+ rrrrr`�'%%%'===�'�'4`^„ O PREPARED BY: �aV� �Gvl�'l�� Before construction is completed �r� �• � "'^ `"''" '� D A T E: t h i s b u i l d i n g w i l l b e i n s p e c t e d f o r �' `-'1a - _ ":� � ; compliance with Section 553.908 ` *, ` �: .: =�.� - I hereby certify that this building,as designed, is in compliance Florida Statutes. ;.�_ _-, �; I with the Florida Energy Code. C�b`�"��= " OWNER/AGENT: BUILDING FFI IAL: DATE: " � DATE: � � ' - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Irisulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. 10/13/2017 7:06 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 ; , , . , --� FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential PerFormance Method Project Name: 2889A1 sf ADS 2017 Builder Name: Lennar Homes 0041 street: 3137 Moulden Hollow Drive Permit o�ce: City of Zephyrhills City,State,Zip: ,FL, Permit Number• Owner• Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa " County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2754.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1308.70 ftZ b.Frame-Wood,Exterior R=11.0 1114.00 ft' 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 331.50 ftZ 4. Number of Bedrooms 5 d.N/A R_ ftZ 5. Is this a worst case? Yes 10.Ceiling Types (2313.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2173.00 ft2 6. Conditioned floor area above grade(ft� 2896 b.Knee Wall(Vented) R=30.0 140.00 ftZ Conditioned floor area below grade(ftZ) 0 °• R= ft : 11.Ducts R ftz 7. Windows(193.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 358 a. U-Factor: Dbl,U=0.54 96.00 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 221 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 64.00 ftZ �2•Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 b.Eentral Unit 18.0 SEER:16.00 c. U-Factor: Dbl,U=0.56 33.33 ft2 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor N/A ftz a.Electric Heat Pump 21.8 HSPF:8.50 SHGC: b.Electric Heat Pump 17.5 HSPF:8.50 Area Weighted Average Overhang Depth: 1.172 ft. - Area Weighted Average SHGC: 0.302 14.Hot water systems 8. Floor Types (2902.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF 0.950 a.Slab-On-Grade Edge Insulation R=0.0 1793.00 ftZ b. Conservation features b.Floor Over Other Space R=0.0 672.00 ftz None c.other(see details) R= 437.00 ftz �5.Credits Pstat Glass/Floor Area: 0.067 Total Proposed Modified Loads: 84.94 pASS Total Baseline Loads: 85.63 I hereby certify that the plans and specifications covered by Review of the plans and _ �:��iE;Sx,��,,, this calculation are in com liance with the Florida Ener � ecifications covered b this, � � ' _�:. - p 9Y P Y ���y _ � �O .��, Code. calculation indicates compliance ��'i+'�;,,��''�' `='.�,.�,�+ . /I with the Florida Energy Code. � `I�, !1{�Ir„�i!. ••;=�:�;;;-";,`�O , rj�_,,' ,_,;:`,. PREPARED BY: _ �aV� f���'l�VL Before construction is completed r� � �. DATE: this building will be inspected for � •. �� = :� - compliance with Section 553.908 *����i' � � * I hereby certify that this building,as designed, is in compliance Florida Statutes. ` ,�.- with the Florida Energy Code. ��'O.~ .��� ' D yvE:.,. OWNER/AGENT: BUILDING OFFICIAL: ' � DATE. DATE: - '� - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. � -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. 10/13/2017 7:06 AM EnergyGaugeOO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 � ; FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2889A1 sf ADS 2017 Builder Name: Lennar Homes 0041 street: 3137 Moulden Hollow Drive Permit office: City of Zephyrhills City,State,Zip: ,FL, Permit Number• Owner• Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2754.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1308.70 ftz b.Frame-Wood,Exterior R=11.0 1114.00 ft' 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 331.50 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2313.0 sqft.) Insulation Area Z a.Under Attic(Vented) R=30.0 2173.00 ft 6. Conditioned floor area above grade(ft2) 2896 b.Knee Wall(Vented) R=30.0 140.00 ftZ Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ 11.Ducts R ftz 7 Windows(193.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH: 1st Floor 6 358 a. U-Factor: Dbl,U=0.54 96.00 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 221 � SHGC: SHGC=0.31 b. U-Factor: Dbl, U=0.56 64.00 ftZ 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 b.Central Unit 18.0 SEER:16.00 c. U-Factor: Dbl,U=0.56 33.33 ftz SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor N/A ft2 a.Electric Heat Pump 21.8 HSPF:8.50 SHGC: b.Electric Heat Pump 17.5 HSPF:8.50 Area Weighted Average Overhang Depth: 1.172 ft. Area Weighted Average SHGC: 0.302 14.Hot water systems 8. FloorTypes (2902.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1793.00 ftz b. Conservation features b.Floor Over Other Space R=0.0 672.00 ft2 None c.other(see details) R= 437.00 ftZ 15.Credits Pstat � Total Proposed Modified Loads: 84.94 pASS Glass/Floor Area: 0.067 Total Baseline Loads: 85.63 I hereby certify that the plans and specifications covered by Review of the plans and ' �'T��S?`,q�, `�.,. this calculation are in compliance with the Florida Energy specifications covered by this ��'a"_ ' "__� '�O . , Code. calculation indicates compliance � ,��!'�,,,'''' `=s�r;.�� K+. �,_�. '"":,� .a`�� '�` with the Florida Energy Code. ti rirr,,,4.��•, -,,;;;�.•;;:��-;��{? :,,...__ , PREPARED BY: �QV� ���� Before construction is completed � �;°� _ �, d DATE: this building will be inspected for ,� k, �,_ compliance with Section 553.908 " *� � � - � ` I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. ` �. ` - with the Florida Ener Code. 9 9 p �G'O'�� ��J. 9Y b y�'i-:.. OWNER/AGENT: BUILDING OFFICIAL: DATE. DATE. -6� • - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. 10/13/2017 7:06 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2Ct14 ' PROJECT Title: 2889A1 sf ADS 2017 8edrooms: 5 Address Type: Street Address 8uilding Type: tSser Conditiqned Area: 2896 Lat# Owner• Lennar Homes Total 5tories: 2 Block/SubDivision: � #of Units: 1 Worst Case: Yes PtatBoak: ' Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: "' County: Pasco Jurisdiction: Who3e Hause Fan: Gity,State,Zip: Family Type: Single-family F�-, New/Existing: New(From Plans} Comment: - GLIMATE j IECC Design Temp tnt Design Temp Heating Design Daily Temp �j Design Location TMY Site Zone 97.5% 2.5°!o Winter Summer Degree Days Moisture Range FL,Tampa FL TAMPA fNTERNATi 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume � 4 Block9 1793 18419.8 2 Block2 11Q3 8$24 SPACES Number (Uame Area Volume Kitchen {lccupanfs Bedrooms InfillD Finished Cooted Fleated 1 1st Floor 1793 15419.8 Yes 2 1 1 Yes Yes Yes 2 2nd Floor 11�3 8824 No 4 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 S(ab-On-Grade Edge Insulatio 1st Flaar 937 ft 0 1793 ftz .___ 0.3 0 0.7 2 Fioor over Garage 2nd Ffoor �_ ..� 437 ft2 91 �.'E5 0 0.85 3 Floor Over Other Space 2nd Floor r__ ..� 672 ftz 0 � 0 0 1 ROOF � � j Roof Gable Roaf Soiar SA Emitt Emitt Deck Pitch �� # Type Materials Area Area Calor Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2419 ftz 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTiC V # Type Ventilatian Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2233 frZ N N 10t13l2017 7:06 AM EnergyGaugeU USA-FlaRes2414 Section R405.A.1 Compliant Software Page 2 of 5 � � ) I FORM R405-2Q14 ` CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 30 Blown 1109 ft2 0.11 Wood 2 UnderAttic(Vented) 1st Floor 30 Blown 1064 ft� 0.11 Wood 3 Knee Wall(Vented) 2nd Floor 30 Batt 140 ftz 0.11 Wood WALLS Adjacent SPa� Cavity Width Height Sheathing Framing Solar Belo 0 1 N=>NE Exterior Concrete Block-Int Insul 1st Floor 4.0999 19 8 8 164.7 ft2 0 0.600000 0 2 E=>SE Exterior Concrete Block-Int Insul 1st Floor 4.0999 58 8 8 502.7 ftZ 0 0.600000 0 3 S=>SW Exterior Concrete Block-Int Insul ist Floor 4.0999 34 8 8 294.7 ft2 0 0.600000 0 4 W=>NW Exteriar Concrete Block-Int Insul 1st Fioor 4.0999 34 8 8 294.7 ft2 0 0.600000 0 _ 5 N=>NE Garage Frame-Wood 1 st Floor 11 19 9 8 8 171.2 ftz 0 0.01 0 _6 W=>NW Garage Frame-Wood 1st Floor 11 18 6 8 8 160.3 ft2 0 0.01 0 _ 7 N=>NE Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ftZ 0 0.600000 0 _ 8 E=>SE E�erior Frame-Wood 2nd Floor 11 29 6 8 236.0 ft2 0 0.600000 0 , _ 9 S=>SW Exterior Frame-Wood 2nd Floor 11 40 S 320.0 ftZ 0 0.600000 0 _10 W=>NW Exterior Frame-Wood 2nd Floor 11 29 9 8 238.0 ftZ 0 0 0.600000 0 _11 S=>SW Exterior Concrete Block-Int Insul 1 st Floor 4.0999 6 8 8 52.0 ft2 0 0.600000 0 i DOORS # Ornt DoorType Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated 1st Floor None .2 3 6 8 20 ft' 2 W=>NW Wood 1 st Floor None .4 2 8 6 8 17.8 ftz WINDOWS Orientation shown is the entered orientation(_>)chan ed to Worst Case. / Wail Overhang \/ # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening � 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 16.0 ftZ 1 ft 0 in 13 ft 4 in None None 2 E=>SE 2 Metal Low-E Double Yes 0.54 0.31 16.0 ftZ 1 ft 0 in 0 ft 10 in None None 3 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 48.0 ftZ 1 ft 0 in 0 ft 10 in None None � 4 S=>SW 11 Metal Low-E Double Yes 0.56 0.32 33.3 ftZ 2 ft 0 in 1 ft 2 in None None � 5 N=>NE 7 Metal Low-E Double Yes 0.56 0.28 32.0 ftZ 1 ft 0 in 0 ft 4 in None None 6 E=>SE 8 Metal Low-E Double Yes 0.54 0.31 16.0 ftZ 1 ft 0 in 0 ft 4 in None None 7 W=>NW 10 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 1 ft 0 in 0 ft 4 in None None 8 N=>NE 7 Metal Low-E Double Yes 0.56 0.28 16.0 ftZ 1 ft 0 in 3 ft 5 in Drapes/blinds None 10/13/2017 7:06 AM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 3 of 5 FORM R405-2014 ' GARAGE # Fioor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 437 ft2 437 ft2 44 ft 8.6 ft 1 INFILTRATION # Scape Methad SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000372 2828.4 155.28 292.02 .3438 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.5 21.8 kBtulhr 1 sys#1 2 Electric Heat Pump None HSPF:8.5 17.5 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 25.2 kBtu/hr 756 cfm 0.85 1 sys#1 2 Central Unit Split SEER:16 18 kBtu/hr 540 cfm 0.85 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 80 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None �2 DUCTS / —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 358 ftZ ist Floor 90 ftz Proposed Qn 1st Floor —cfm 53.8 cfm 0.03 0.60 1 1 2 Attic 6 221 ft2 2nd Floor 55 ftZ Proposed Qn 2nd Floor� —cfm 33.1 cfm 0.03 0.60 2 2 10/13/2017 7:06 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 ,- � _ FORM R405-20�14 ' II TEIIflPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb [ ]Mar A r Ma X Jun Jul X Au X Se Oct Nov Dec Heating �Jan �Feb [X]Mar f �APr f �May 4 �Jun ��Jul 4 �Au9 4 Sep Oct Nov Dec Ventin Jan Feb [X]Mar [X A r [ Ma [ Jun Jul [ Au [ Se Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference � Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 SO 80 80 SO i PM 80 80 78 78 78 78 78 78 78 78 78 78 i Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 �I Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 _ PM 68 68 68 68 68 68 68 68 68 68 66 66 10/13/2017 7:06 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 � .. ��`, 1 _ ' . FORM R405-2014 � " - --' ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. „ FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1308.70 ft2 b.Frame-Wood,Exterior R=11.0 1114.00 ft 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 331.50 ft2 4. Number of Bedrooms 5 d.N/A R= ftZ 10.Ceiling Types Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2173.00 ftZ 6. Conditioned floor area(ft�) 2896 b.Knee Wall(Vented) R=30.0 140.00 ftz 7. Windows'* Description Area c.N/A R= ft Z a. U-Factor: Dbl,U=0.54 96.00 ftZ �1.Ducts R ft a.Sup:Attic,Ret: 1st Floor,AH:1st Floor 6 358 SHGC: SHGC=0.31 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 221 b. U-Factor. Dbl,U=0.56 64.00 ftZ SHGC: SHGC=0.28 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.56 33.33 ftz a.Central Unit 25.2 SEER:16.00 SHGC: SHGC=0.32 b.Central Unit 18.0 SEER:16.00 d. U-Factor N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 21.8 HSPF:8.50 Area Weighted Average Overhang Depth: 1.172 ft. b.Electric Heat Pump 17.5 HSPF:8.50 Area Weighted Average SHGC: 0.302 S. Floor Types Insulation Area 14.Hot water systems : a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1793.00 ft EF 0.95 b.Floor Over Other Space R=0.0 672.00 ft2 c.other(see details) R= 437.00 ft2 b. Conservation features None 15.Credits Pstat • I certify that this home has complied with the Florida Energy Efficiency Code for Building • ;����,. - Construction through the above energy saving features which will be installed (or exceeded) :�,o� " _.'�TAo - in this home before final inspection. Otherwise, a new EPL Display Card will be completed y�v'h;�°����' •_�:�,o:';'� based on installed Code compliant featur . � ��i„�•-; •_:�;::��,ti o � ,/ .\�F.:.. �. w( . �` .��.� Builder Si nature: ,� � �"��u" � g Date: 10/12/17 �: :��(�:.,�. � �. � � Address of New Home: 3137 Mou en Hollow Drive- Ciry/FL Zip'Zephyrhills, c � . FL 33540 . � .` 5�' � oD yvE'� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support , staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/1 3/201 7 7:07 AM EnergyGauge�USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 � ; , Buildin Anal $�$ " __ Job: 2889A1 sf ADS � Y Date: 1 011 312 01 7 lower floor By: Dave BAYONET PLUMBING COOLING_�HEATING ' � - • • � For. Lennar Homes � - • • � � Location: Indoor: Heating Cooling - Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 17 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 53.6 Dry bulb(°F) 31 92 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ftz Btuh % of load Walls 5.5 6957 30.1 �� Glazing 30.2 3426 14.8 wau nfilVatlan Doors 21.2 419 1.8 Ceilings 1.3 1450 6.3 Floors 3.3 5951 25.8 I nfiltration 2.1 2877 12.5 - Ducts 2020 8.7 Plpl�g 0 0 F�aors Humidification 0 0 Glazing Ventilation 0 0 o�er. Adjustments O Ceilings Total 23100 100.0 • • • Component Btuh/ftZ Btuh °/a of load Walls � 2.9 3724 19.3 Glazing' 54.3 6167 32.0 wa��s Intemal Gains Doors 17.2 340 1.8 Ceilings 1.7 2021 10.5 Floors 0 0 0 Infiltration 0.5 684 3.5 �ucts D ucts 2360 12.2 • Ventilation 0 0 ' Internal gains 3980 20.6 Infiltration BIOw2f 0 0 Glazing Adjustments O Ceilings Total 19276 100.0 Other Latent Cooling Load=2905 Btuh Overall U-value= 0.107 Btuh/ft2-°F Data entries checked. -� �- wrigF�tsoft9 2017-Oct-1307'10:52 �� Rfght-Suite�sl Universal 2017 17.0.23 RSU05714 Page 1 ...BA27UHE AH's\2889Asf template ADS 1.5-2ton.rup Calc=MJ8 Front Doorfaces:SE r � BV��d�n Anal $�S Job: 2889A1 sf ADS � y Date: 10/13/2017 upper floor By: Dave BAYONET PLUMBING COOLING HEATING ' � - • � For: Lennar Homes � � - • • � � Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 17 Latitude: 28°N Relative humidity (%)� 50 50 Outdoor: �Heating Cooling Moisture difference(gr/Ib) 34.7 53.6 Dry bulb(°F) 31 92 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 � Component Btuh/ft2 Btuh % of load Walls 3.8 3623 33.1 �«5 Glazing 30.2 2386 21.8 DOors 0 0 0 Wa�� Celll Ilgs 1.3 1384 12.6 nfi�tratian Floors 2.0 30 0.3 I nfi Itration 2.1 2121 19.4 D ucts 1402 12.8 � Piping 0 0 ou,er Humidification 0 0 Ceilings Ventilation 0 0 Glazing Adjustments 0 Total 10946 100.0 • • • Component Btuh/ftz Btuh % of load Walls 2.9 2718 21.3 Intemal Gains Glazing 52.2 4127 32.4 walls Doors 0 0 0 Ceilings 1.7 1874 14.7 Floors 0.9 14 0.1 ucts Infiltration 0.5 504 4.0 Ducts 1682 13.2 � Ventilation 0 0 �nfiltration Internal gains 1820 14.3 Other BloWer' 0 0 Glazing Adjustments 0 Ceilings Total 12739 100.0 Latent Cooling Load=2049 Btuh Overall U-value= 0.088 Btuh/ft2-°F Data entries checked. .... +�- wrightsoftm zo��-oot-�s o���o:s2 �� , Right-Sufte�sl Universal 2017 17.0.23 RSU05714 Page 2 ...BA27UHE AH's\2889A sf template ADS 1.S2ton.rup Calc=MJ8 Front Door faces:SE Pro ect Summa Job: 2889A1 sf ADS J � Date: 10N 3/2017 lower floor By: Dave � BAYONET PLUMBING COOLING H.EATING ' � - � • For: Lennar Homes Notes: 2017 � - • • � Weather Tampa InternationalAP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 92 °F Inside db 70 °F Inside db 75 °F Design TD 39 °F Design TD 17 °F Daily range L Relative humidity 50 °/o Moisture difference 54 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 21080 Btuh Structure 16917 Btuh Ducts 2020 Btuh Ducts 2360 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23100 Btuh Use manufacturer's data y ', Rate/swing multiplier 1.00 Inflltl'atlon Equipment sensible load 19276 Btuh nnethod Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2502 Btuh Ducts 403 Btuh Central vent(0 cfm) 0 Btuh , Heating Cooling (none) Area(ftz) 1793 1793 Equipment latent load 2905 Btuh Volume(ft') 16024 16024 Air changes/hour 0.25 0.13 Equipment Total Load (Sen+Lat) 22181 Btuh Equiv.AVF(cfm) 67 36 Req. total capacity at 0.85 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary ', Make Lennox Make Lennox ' Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-024230-21 Cond 14HPX-024-230-21 AHRI ref 10258598 Coil CBA27UHE-024230*++TDR AHRI ref 10258598 Efficiency 8.5 HSPF Efficiency 13.5 EER, 16 SEER Heating input Sensible cooling 21420 Btuh Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh Temperature rise 25 °F Total cooling 25200 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.87 Capacity balance point= 33°F Backup: Input= 6 kW, Output=22126 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .c. wri htsoftm 2017-Oct-13 07'10:52 .�_ g Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 �� ...BA27UHE AH's\2889Asf template ADS 1.5-2ton.rup Calc=MJ8 Front Doorfaces:SE } � Pro ect Summar�� Job: 2889A1 sf ADS 1 '7 Date: 10/13/2017 upper floor By: Dave BAYONET PLUMBING..COOLING HEATING ■ . - . . For: Lennar Homes N otes: 2017 � - . • � . I Weather: Tampa InternationalAP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 92 °F Inside db 70 °F Inside db 75 °F Design TD 39 °F Design TD 17 °F Daily range L Relative humidity 50 % Moisture difference 54 gr/Ib . Heating Summary Sensible Cooling Equipment Load Sizing Structure 9545 Btuh Structure 11057 Btuh Ducts 1402 Btuh Ducts 1682 Btuh � Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 10946 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 I Infiltration Equipment sensible load 12739 Btuh i Method simplified Latent Cooling Equipment Load Sizing ' Construction quality Semi-tight Fireplaces 0 Structure 1760 Btuh Ducts 289 Btuh Central vent (0 cfm) 0 Btuh Heatin Cooling (none) Area(ftz) 110� 1103 Equipment latent load 2049 Btuh Volume(ft3) 8824 8824 Air changes/hour 0.33 0.18 Equipment Total Load (Sen+Lat) 14788 Btuh ' Equiv.AVF (cfm) 49 26 Req. total capacity at 0.85 SHR 1.2 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-018-230-21 Cond 14HPX-018-230-21 AHRI ref 10258596 Coil CBA27UHE-018-230"++TDR AHRI ref 10258596 Efficiency 8.5 HSPF Efficiency 13.0 EER, 15 SEER Heating input Sensible cooling 16915 Btuh Heating output 17100 Btuh @ 47°F Latent cooling 2985 Btuh Temperature rise 26 °F Total cooling 19900 Btuh Actual air flow 600 cfm Actual air flow 600 cfm Air flow factor 0.055 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.86 Capacity balance point= 20°F Backup: Input= 3 kW, Output= 10697 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .� -�- wrightsoftm 2017-Oct-1307•10:52 .+- Right-SuRe�Universal 2017 17.0.23 RSU05714 Page 2 '�� .BA27UHE AH's\2889Asf template ADS 1.5-2ton.rup Calc=MJ8 Front Doorfaces:SE r ; Manual S Compliance Report �ob: 2889A1 sf ADS Date: 1011312017 lower floor By: Dave BAYONET PLUMBING COOLING HEATING ' � - • � For: Lennar Homes • • • • • Design Conditions Outdoor design DB: 92.4°F Sensible gain: 19276 Btuh Entering coil DB: 75.7°F Outdoor design WB: 77.4°F Latent gain: 2905 Btuh Entering coil WB. 62.9°F Indoor design DB: 75.0°F Total gain: 22181 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SpIitASHP Manufacturer: Lennox Model. 14HPX-024230-21+CBA27UHE-024230'`++TDR Actual airflow� 800 cfm Sensible capacity: 21420 Btuh 111% of load Latent capacity: 3780 Btuh 130°/a of load Total capacity: 25200 Btuh 114% of load SHR: 85% � � � • � Design Conditions , Outdoor design DB: 30.8°F Heat loss. 23100 Btuh Entering coil DB: 69.6°F Indoor design DB. 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Lennox Model 14HPX-024230-21+CBA27UHE-024-230'`++TDR Actual airflow: 800 cfm Output capacity: 21800 Btuh 94% of load Capacity balance: 33 °F Supplemental heat required: 1300 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 6.5 kW 96% of load Temp. rise: 50 °F Meets are all requirements of ACCA Manual S. ,� wri htsoft° 2017-Oct-13 07�10:53 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 �� ...BA27UHE AH's\2889A sf template ADS 1.5-2ton.rup Calc=MJ8 Front Door faces:SE - . . � Manual S Com liance Re ort Job: 2889A1 sf ADS p p Date: 1 011 312 01 7 �� upper floor By: Dave BAYONET PLUMBING COOLING HEATING ' • - • � For: Lennar Homes � • • • � Design Conditions Outdoor design DB: 92.4°F Sensible gain: 12739 Btuh Entering coil DB: 75.8°F Outdoor design WB: 77.4°F Latent gain: 2049 Btuh Entering coil WB 62.9°F Indoor design DB. 75.0°F Total gain: 14788 Btuh Indoor RH: 50% Estimated airflow: 600 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Lennox Model: 14HPX-018-230-21+CBA27UHE-018-230*++TDR Actual airflow: 600 cfm Sensible capacity� 15300 Btuh 120% of load Latent capacity: 2700 Btuh 132% of load Total capacity: 18000 Btuh 122% of load SHR: 85% . • • Design Conditions Outdoor design DB: 30.8°F Heat loss 10946 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SpIitASHP Manufacturer: Lennox Model: 14HPX-018-230-21+CBA27UHE-018-230"++TDR Actual airflow: 600 cfm Output capacity: 17500 Btuh 160% of load Capacity balance: 20 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip � Manufacturer: Model: Actual airflow� 600 cfm Output capacity: 3.1 kW 98% of load Temp. rise: 50 °F Meets are all requirements of ACCA Manual S ,,.� wri htsoft' 2017-Oct-13 07�10:53 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page 2 �� ...BA27UHE AH's\2889A sf template ADS 1.5-2ton.rup Calc=MJ8 Front Door faces:SE Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. 9. No electric, plumbing, mechanical, or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations reguiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. A112008 N.E.C. Codes will be enforced. 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. 25. A copv of the enerQ-v cacls shall be with nernzit at all tinies. 26. Conv of�nal insulation renort shall be nrovided with nermit before fcnaL F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 5�'Edition , R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008) . . = J� -. E � r=.i ; ,� � : � �� ' . . AV � ; �.�,�.,.......�.r....��.,.� 1� � �,� � � � ..�.. _ ....;.. � -- • � • : ����� - w. �:,,_,�.��.... �_�_.� ; - . .�._.�.. ,�_ �,.,� '��+�� � _ ; ..r�: , -- , � �►'`� 1 � ='' ; � .�, . . � . r;,�', � �`� �?' ��: I � . �,,..�� � ' �� � _ ,- J _ � �� l � _ �-�' 't 1 ��. �� ; o�- ,� �Q 1 ,� .� �� �,� 11 .� _ �� ,.. � �.�of ,. �`. �� - �. � ��� • � � � 1 �, � ' � "v�.,. --�.."� : j ,y�� ` .; � , . . �,.,,,, .,,; �1e !., tr.,,, t'I�Y' ���. \ ` +�, '�_ ,1- '� ' r '- _ �t ",,,�.- `,,..,,,�,J�'j 1'... �. . � � 1 � 39 t. � � `v �� �' �� ��.e� -�� r ` � � � � � A - � - ,,� -, � � r � - � � . ��: , p� - '��, � � ;� . 1 � 4� �.. �,�.5,� � .� '� . .��� ��,�� ,� . ,4 'i.�DC7 � /'� � Y� � � , �' `�' A r �. , ��:- _ •� � � .� �� �' � , ! ��i,.1 'i .� ,;..,' ., � � '� �,ti' r ��+ ~�- F- � _ l ` 7�p �� �. �' ., ., , ,t \ �'� i �`'� '+,� �' .r "'�' `' . 1�.'� � � a . ,•� . � ,-T�.�o �.r � ,� � ! • � �� ', � �. " FR EL �} �- A. ►' ti'*.� �'�t�'`�J' 1 �` � �' 4 �.�" 1:: ,� �� `� �s ,�`•� ' .� �. ; . .:�� ;�.�� �' �, . ,�. .. ,� a ' . � - .,, , 1 �a; � '� � � - � , . 1} � � �� ` L.�, - ` -�, 72�'8 .' � �� ' '� , .` �° �'''t"�� 'ti.� � �'1F --�w.'.' . ,•'' `� ., � � �� � ��� �� `.� �� .+'� .� � '�..`,. � ' �` � � 1 . � , .. � � � �. :y��4� ,� � . �a � 1 ,�' � 1 1,�,�' ,,•• �� ,,� �;►��`�. FF�I. ' .r• . �I '� r.�:7o � -'�u�, 1 \� i;, .;;r•�'t ,. �. �'7'�`�/ c�r'° !� � L A �� _� '�� .,,"•'� '' �' ��► � ��� �,- � ,� . � 1 ,,�? �.�,. ���,� � �` � A � ,- T�AO� 'l `. , , �• 1 �,,.•'' y.%1 '�M 7...�5 �, � FF�3. `'' .�.w..... ''�' �- ,� � � � �� � � ,� �,,�, r.r � �.,�!! � �:,� ��, • ..,.__ �. ` '� l h'~ '�,� 1�I�r,,.�''' �- • ' � 1 ,� �` � -�.� ' �t � � f � �•..• ,.�� . - �',. -, �- . �'�'�' �` .�� ��_ , — ����""�r"�rrr'1 1 : �1 �' : , l'►T � �"� :�' . l . t �1r �'� PLOTPLAIt�! � SKETCH ONLY SEC. 24 , TWP. 26 S, RNG. 21 E. NOT A BOUNDARY SURVEY LOT 41 BE"R'"� e�s` HIDDEN RIVER PHASE ONE A � Norrn+ souNonRr oF sue,iEcr ainr e�wc s sg+o•�s- E PASCO COUNTY, FLORIDA. �T 7H15 SURVEY IS SUBJECT TO ANY FACTS THAT 1� YAY 8E OISCLOSEO BY A FULL AND ACCURAiE TITLE SEAR(�1. AL50 SUB.�CT TO SETBApCS, EASEUEN75 ANO RESTRICT10N5 OF RECORD. PREUMINARY DRAWING: � UNDERGROUND FOOTER, S�F�r wau, ewo THIS PLAN IS FOR PERMITi1NG PURPOSES UNOERGROUND U7IUTIES ARE NOT LOCATED OR ONLY, NOT FOR CONSTRUCTION. VERIFY o �0�. ALL DIA1ENSlONS BEFORE ANY CONSTRUCilO�Y_ ' � ' DO NOT SCaLE iH15 PRINL DIUENSIONS AND 'LEGEND: � NOTES TAKE PREFERENCE. �—�= PROPOSEO DRAINAGE fLOW � (00_00)— = PROPOSED GRADE N CERTAIN DATA SHOVM HEREON BASEU ON E-00_00 = EXISi1NG (�2ADE ENpNEERMG PLANS PROViDEO BY CUEt�T SiRUCTURE 71E5 SHOwTI HEREOr1 DENOTES uEASUREUEN7 FRObt FOR�+1 BOARDS/�OUNDATION TO PROPERTY UNE. - = 10' DRA�NaGE/UitUTY FASENErff TRACT '0" uwOSCA.E�sEuErrt � ON LOT AREA CALCULATIONS I � . LOT = 8153.91 gQ. � ��j � LMNG AREH = 1779 So. fT. �j5- y ENTRY - 26 . Sa. FT. �j1. � - � COVERED L.ANAF = � �_ FT. I �1 6�'�6 .)_- � PAT10 = 23 50. FT. � \ CONC_ DRNE 357 SO. fT. - ;=. i a/c a� coNc Pnn = ,s �_ Fr_ PRIVATE 90EYVALK = 31 SO. FT_ ' PLAi 1 O�ERIAOUS = 32 S BOUNDaRY I -._�s� , � = 2640 So_ FT_ � +:� --. •.o� a SOD = 55t4 50. FT_ -''- �' LOT 40 �'� _ OFF LOT AREA CALCULATIONS 'O:Q P' RIGHT� WAY = 447.03 SO. Fi. G ��,c O�_ DRIVE APRON 144 so. fT. IN 78.69'- - :t s��� PUBLIC SIOEWALK = 152 SO. FT. N Z '� �p 157 SO. FT Kj LOT 41 N, °' �� o i TOTALS I w. P�° �"�� - _O p��p = 8600.94 So. FT. �Gg� p_ ORIVEWAY 501 SO. FT. SIOEWAIJC 783 SO. FT. d1 � `��. G�� _ $Q� _ S66S SO. fT. i � �� � _ � N �o-�°• 0 o . o.,. --s���Q. :. Z _�6oA: '�:'_a o • � -��Y ^�1i •':�-� �„ ' --- ---°a.oa• -. .•ao' j -; - . :��y� �N .. --•-------• - TRaCT "D" - -`'. s•_ - - ' a p O�uG:dc � o= '-�s �.r.�-"- S 6 Z26_ Ii.VDSCAfl''c EASOufNf 0a1 m= 48� � • " - �` : / '•- -• G6.5'.y_. .:pp�•- •�sr10 / — I — N 89'S3'28" W 63.92'��z°_ - ..�.�� Q�pl I ,• �__ � �i � �ti - - . �_, _ N PIAT� �PRM(P) TRAC7 "D" �O� ,`'� - BOUNDARY Il�pSCApE�E�T / �O� O� j � O`��, �or c2 �0�� l5� NOTES: / lOT GRADING TYPE = A PROPOSED PAD ELEVATI�1 = N/A FRONT�THACK = 20' 510E SEiBApC = 10' REAR SETBAqC = 10' CURVE DATA PROPOSED: a,R+r i w+�:us aac c}a�o e=r�a,�c oe�rn LOWEST FLOOR ELEVATIONS: ce3 es.00• �s.n• is.�s- s s<r,e-oz-w ,o-3rs�- LMNG AREA: 73.50' GARAGE AREA: DESCRIQ�TION: ELEVATIONS REFERENCEO TO LOT 41, MAP OR PLAT ENTITLED "HIDDEN RNER PHASE ONE A", NATIONAL GEODETIC VERTICAL AS RECOROED IN PLAT BOOK 074, PAGES 101 THROUGH 121, DATUM OF 1929. MEAN SEA OF THE PUBUC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00_00 �i. APPARENT FLOOD HAZARD ZONE: "X" COMMUNIN PANEL NO. 120230 0460 D EFFECTNE DATE: 9/30/1992 Projeci �Sumber Square FeeL- 8153_91 t �NNAR HOIJES LEG�t�D: (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, g= CENTERUNE. A/C= A1R C�CPI'D9ApNER;=B/C= BApC OF CURB,C/5= CO.i4'Rc7E SLAB. GY= CHOetD. CHB= CHORO BEARING. CIF= CHAtN UNK FENCE, CONC= CONCRETE: COV_= COVERE[�.:E%PF.EQCs�O�F��VEI,IEN7, E9d'7= EASE4ENT, - F/C= FENCE CORNER, FCM= FOUND CONCRETE MONU►IENT, FIP= FOUND IRUy PIPE. FlR= FOUND IRON ROD.;FN+!�G.�e�i7iJNu PiA�IL�•r`dc�D45K, FPP= FOUND P1HqiE0 PIPE. LFE= L014�57 FlOOR ElEVA710�V, 6fA5.= MASONRY, OR= OFFlpAL RECORO BOOK, P8= PLAT BOOK. RCP= PcR1,lAFl�p3��ONIfifJ�l�OINT, PRY= PERYANENT REFEReNCE 6SO,�UMENT, R/W= RIGtIT OF WAY, R= RAp1U5. SIR=SET 1/2- IRON ROD dc CAP No_ 4493, SNdcD�=��E�1�NtiL-..3�5-DI'SK:;T'c3!IA=,',�E�PORARY BENpi1JARK, U = UTILiTY POLE. Y! = P100D FENCE R = RADIAL ` JOHN R.BEACH&ASSOCIATES.INC. �`O�' BY � ; — � � '' � � SUR�YORS Mf0 61APPERS _- __,.., ,�.,N-�,: ;'"� ' 9i1 W5T ST. PETER59URG ORIVE �ecked B�r ` � , ONE OL05.1AAR. FLORIDA 34677 �� ' ' '—-� � WAY (813) 85t-1276 FAX (813) 855-8370 �ale: '�_�, -_ �"_'^,, i �\, - �- :-, ,-< � 9 !3 Zo, ., - N07 VAUD w1iHW7 iHE S�G.vA7URE AND Datec PLOT PLAN 9/OS/2017 GH - � - THE 021GINAL RA15£D SEAL OF A F�ORIDA JO BEACH � '-�-�'- ^' - pA UCENSEO SUR�YO� AND MAPPER ORID EG. LAtJD SLIRVEYOR No. 2984 LB 4493 Rev:sions: REI/ISED PER DESCRIP710N 9/73/77 JBS Jacqueline Boges From: Nichole Spence(FATHOM)<support@gwfathom.zendesk.com> Sent: Wednesday, February 14, 2018 4:32 PM To: Jacqueline Boges Subject: [FATHOM �-3 3T-Moul`d`en Hoflaw Dr water/sewer ##- Please type your reply above this line -## 1 ��v ��-� l, Your request (#195114) has been updated. REPLY TO THIS EMAIL or click the link below: https://gwfathom.zendesk.com/hc/requests/195114 �-- ---, ' -� � Nichole Spence (FATHOM) �---1-� Feb 14, 2 32 PM MST Account # 889145-2983399 has been created; service order to follow once mapping has been completed. Best Regards, Nichole � FATHOM Support ,-�� ; Jacqueline Boges .__. , , -- --- � Feb 14, 8:00 AM MST New service 3137 Moulden Hollow Dr need water, sewer and water 3/4 meter this order was suppose to be done in November 2017 and it was so I am asking could we have this order rush out to site sorry about the last minute but would appreciate anything you could do to get this meter out This email is a service from FATHOM. 1 Jacqueline Boges I� From: Holly Zaragoza(FATHOM)<support@gwfathom.zendesk.com> I'� Sent: � Monday, February 19, 2018 4:02 PM To: Jacqueline Boges Subject: [FATHOM] Re: 3137 Moulden Hollow Dr water/sewer ' ��o�� ##- Please type your reply above this line -## - � �� Your request (#195114) has been solved. TO REOPEN THIS REQUEST, reply to this email or click the link below: https://gwfathom.zendesk com/hc/requests/195114 � Holly Zaragoza (FATHOM) Feb 19, 2.02 PM MST Created Meter install SO. Best Regards, Holly � Client Support Manager FATHOM Support ; ��� � Nichole Spence (FATHOM) � ._-a` � `�—-� Feb 14, 2:32 PM MST Account # 889145-2983399 has been created; service order to follow once mapping has been completed. Best Regards, Nichole � FATHOM Support � )acqueline Boges -----� Feb 14, 8 00 AM MST New service 3137 Moulden Hollow Dr need water, sewer and water 3/4 meter this order was suppose to be done in November 201 7 and it was so I am asking could we have this order rush out to site sorry about the last minute but would appreciate anything you could do to get this meter out This email is a service from FATHOM. 1 � t Jacqueline Boges From: OPC Engineering<opcengineering@mail.wrec.net> Sent: Monday, February 19, 2018 4:19 PM To: Jacqueline Boges Subject: Re: release permanent power Thank you ---- Original Message---- From: "Jacqueline Boges" <jboges@ci.zephyrhills.fl.us> Sent: 2/19/2018 3:45:50 PM To: "opcengineering@wrec.net" <opcengineering@wrec.net> Subject: release permanent power Hello Jackie with the City of Zephyrhills could you please release permanent power for 3137 Moulden hollow dr(Hidden River subdivision)bp#19065. I also need acknowledgement that you received this email so I may place in the permit file. Thank you x __ dackie Boges 813-780-0020 ext 3�13 "A rule I have had for years is:to treat the Lord Jesus Christ as a personal friend. His is not a creed,a mere doctrine, but it is He Himself we have"Dwight L. Moody Florida has a very broad public records law. Electronic communications regarding most City of Zephyrhills business are public records and available upon request. Your e-mail I communications may therefore be subject to public disclosure. If you received this message in error, please do not read, forward, copy, etc. and delete immediately. , 1 5335 - 8TH STREET (813)780-0020 -- � ` CERTIFICATE OF OCCUPANCY Address: 3137 MOULDEN HOLLOW DR Owner: LENNAR HOMES LLC �, ZEPHYRHILLS, FL. 4600 WEST CYPRESS ST STE 200 � Subdiv: HIDDEN RIVER TAMPA, FL. 33607 Parcel: 24-26-21-0090-00000-0410 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19065 Date: 3/ 2018 ' L�� � ISSUED BY: BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE