HomeMy WebLinkAbout17-19068 , __; D CITY OF ZEPHYRHILLS
• " ' S335-8TH STREET �•'�
�sls��so-oo20 19�68
' � BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
i PERMIT INFORMATION � LOCATION INFORMATION
Permit#:19068 Issued: 11/29/2017 Address: 3186 MOULDEN HOLLOW DR
Permit Type: NEW SINGLE FAMILY DWELLING � ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 225,863.25 Total Fees: 14,334.97 Subdivision: HIDDEN RIVER
Amount Paid: 14,334.97 Date Paid: 11/29/2017 Parcel Number: 24-26-21-0090-00000-1060
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 WEST CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA FL 33607
Phone: (813)574-5743 Lic: Phone:
Work Desc: CONSTRUCT SINGLE FAMILY 2,005 SQ FT
APPLICATION FEES
PLUMBING FEE 129.90 SEWER CONNECTIO RESIDEN" 2,010.00 ELECTRICAL FEE 194.85
WATER.CONNECTION RESIDENI 641.00 MECHANICAL FEE 90.93 SCHOOL IMPACT FEE-sfd 1% 48.28
SCHOOL IMPACT FEE-sfr/100% 4,828.00 TRAFFIC IMPACT FEE 1% 36.32 TRAFFIC IMPACT FEE 99% 3,595.68
BUILDING FEE 963.32 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00
FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56
/�,���
r "�
V V �
' t�?�G����� �6
� � a
Ins ections Re
FOOTER 2ND ROUGH PLUMB MIS INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTO S SI NATURE PERMIT OFFI
PERMIT E PIRES IN 6 MONTHS 11VITHOUT APPROVED INSPECTIO
CA L FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
- . � � . � � _ � � l llllll lllll lllll llll�llll!Illll lllll lllll11111 llill llll(!II
. 2017182065 - , ,
. ' , Rcpt:1909816 Rec: IQ3.00 "
_ " , � , DS: 0.00 IT: 0.00 �
11%1612017 K, R. , ppty Clerk �
PRULR S 0'NEIL,Ph.D PASCO CLERK & COMPTROL.LE
11/16/2@17 02:26 m 1 of 1 - =
�. . q�_ �� ��i�� P� 1085 -
Permit No. . Parcel ID Na 24-26-21-Oq60-00000-1060
NOTICE OF COMMENCENIE�iT
State of Flarida Coun#y of Pasco � ,
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713, Florida Statutes,
the fo!lowing in4ormation is prov�ded in this Notice of Cammencement: `
1. Description af Property- Legai H(DDEhl.RiVER PHASE ONE A PB 74 PG 101 LdT 106 _
street Address: 31$6 Mouldell Hollow Drive zephryhi(Is F� s35ao
z. General Description af Improvement Single Family Residence/Pool/Screen Enclosure/Fence '
3. Owner Information: Lennar'Homes, LLC � �
- Name '
4600 V11 Cypress St, Ste 200 Tampa _ FL. 33607
- Address City State •
� (nterest in Praperty� . ,
Name of Fee Simple Titleholder. N�A ,
� {(f other than awner} ,
Address City State '
4. contractor� . �ennar Flomes, LCC , .
Name , '
, , 460Q W Cypress St, Ste 200 Tampa FL, 336Q7 .
. , Address Gity �State
� Contractor's Telephone No.. 813.574 57Q0 ,
5. Surety� "' N/A ' �
� Name � � ,
Address City State
� Amount of Band: $ Telephone Na.: '
- s. ` �ender N/A � ' �
Name ; �
Address � , City � Sfafe �
' Lender's Telephone Na.. ,
� 7 Persons wiftii� the 8tate of F3orFda designated by the owner upon whom notices or other documents may be served as provided by
� Section 713 13(1)(a)(7),Florida Statutes. � , �
, Lennar Homes LLG _
- , , Name � _
�4600 W Cypress St, Ste 200 Tampa F�, 33607
, Address � City State `
� Telephone Number af Designated Person: 813 574 570Q
8. !n addifian to himself,fhe owner designates N�t� of
to receive a copy of the Lienor's Notice as provided in Sectian 713:13(1){b),F'lorida Statutes.
� Telephone Number of Person or Entity Designafed by Owner•u '
9. Expiration date of Notice of Commeacement is one year from fhe date oi recording unless a cfifferenf dafe is specifed:
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION•713,13, FLORIDA STATUTES, AND CAN
F2ESUl.T IN YOUR PAY[NG TWICE FOR (MPROVEMENTS TQ YQUR PROPEFZTY. , A NOTICE OF C{}M(vi�NCENiENT MUST BE
RECORDED AND PdSTED ON THE JOB S{TE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO dBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR,AN ATTORNEYBEFORE COMMENCING WORK OR REGORDING YOUR NOTICE OF COMMENCEMENT.
STATE OF FLC}RIDA —L�-ti l � �
COUNTY OF PINELLAS �-'��
5ignature af Owner or Owner's Authorized OfficerlDirectorlParfnerlManager
Vice President
, r 8ignatory's Title/O�ce
The foregoing instrument was acknowledged before me this 6 day of �arCh ZO�� ,by -
Steve Robert Smith as Vice President {type oi a ttt4; ��.,officer,trustee,attarney in tact)for
Lenii�r Homes' LLC (name of n'be�of whom instrument was ezecuted). , ".
� Persona(ly Known�OR Produced identification❑ - Notary �gnature
� Type of Identification-Praduced..� � ' Name(Print) E�ISS olleran �
Verification pursuant'to Section 92.525,�F(orida.Statutes. Under penalties of perjury, (declare that!have read the foregaing and that the facts stated in
it are t�ue to'the b'est of,my knoivledge.and belief �, - .
' � � .
, r��+�' ELISSKM.,NOLLEPoqN Signature of Natural Person Signing Above
.,�Cimmlaelon,�FF 88583T � , .
� ��;�o,�,�, �'=���1rea June 6,2020 `
•, wpdata/bcs/bcs form; ' „f��''� MndalThruTroyFaloin+unncelOQ�3i5�7DiD
� ,,._, _''c . , . _. . . .
i ,
� . .
� �' t
'
��,�����Co ��:�'�����Fi��R�DA, COUWTY OF PASCO
o ��`� 1"HIS IS TO CERTIFY TMAT THE FOREGOIMG iS A
� ° m�>+ TRUE AND CORRECT COPY OF THE DOCUMENT
��• , �''� � ���F'ILE OR C�F PUBLIC RECORD IN THIS OFFICE
���'� � WITN S�MY HAND AND OFFICIAL SEALTHIS
� � In(�3oC�"We'1'rust o � I � ` •�,
:...o�... ��i ^DAY OF "I�� .- : 2 �("")
T � F�AULA S.O'iV�IL, CLERK 8�COMPTROLLER
� • :.��. � • '�
�c . ���7 BY '������..DEPUTY CLERK
���OF���`��
- Jacquelin� Bog�s
I From: TQ Randolph (FATHOM)<support@gwfathom.zendesk.com>
Sent: Wednesday, March 14, 201812:50 PM
To: Jacqueline Boges -
Subject: [FATHOM] Re: 3186 Moulden Hollow Dr New
##- Please type your reply above this line -##
Your request (#201281) has been updated. REPLY TO THIS EMAIL or click the link below:
https://qwfathom.zendesk.com/hc/requests/201281
� �___ ' TQ Randolph (FATHOM)
`--�-� Mar 14, 9:50 AM MST
Mi Jacqueline,
Account 889145-2985959 has been established for this location and is pending mapping by
our GIS team. Once mapping is complete, a service order for meter install will be generated.
Thank you!
' Best Regards,
TQ� FATHOM Support
� Jacqueline Boges
- �-� Mar 14, 6'21 AM MST
Hello Forgot to mention could you rush this request more than normal. This service should
have been ordered back in November and I missed it. Thank you for any help you may assist in
giving to move this along expendient.
f - Jacqueline Boges
�...--=- 1
Mar 14, 6 1 8 AM MST
New 31 86 Moulden Hollow Dr water, sewer, water meter
This email is a service from FATHOM.
i
Jacquelin� Bog�s ',
From: FATHOM <support@gwfathom.zendesk.com> '�
Sent: Wednesday, March 14, 2018 9:19 AM �I
To: Jacqueline Boges '
Subject: [Request received] 3186 Moulden Hollow Dr New
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
B
est Regards,
FATHOM Support Team
TO ADD ADDITIONAL COM
MENTS, reply to this email or click the link below:
https://awfathom.zendesk.com/hc/requests/201281
j � � lacqueline Boges
E �-- - Mar 14, G:1 8 AM MST
New 31 86 Moulden Hollow Dr water, sewer, water meter
This email is a service from FATHOM.
,
i
S
_ PASCO COUNTY
PAS C�Y'�}[^^ DEVELppMENT SERVICES
8731 CiEizens Drive Date:2/14/2018
COUNTY FLORIDA New Part RicFiey,FL 34654
t:7r��aa�r.ac-�.�c.Li�rw;�rPLnr.:�c, 727-B47-2411
�'� 1 �@�� � i ��lV1�� �k*
Receipt#: 1737960
FEE DESCRIPTION ACCOUNT CODE UNITS IM/O10E# FEE AMOUNT PAID RECEIPT# DA7E
Impact Fee Residential Solid 24503100-329010 6.00 1320011 $328.44 $328.44 1737960 2/14/18
Waste Single Family
TOTALS: �328.44 $3Z8.44
Receipt# Paid gv Check CC u # Cashier ID Workstation Fieceiut Date Amt Paid
3737960 Check 11890 540 BCCCP08W 02/14/2018 $328.44
Totaf Payments: $328.44
Pavor Address phone
Lennar Homas 4600 W Cypress Street, 813-574-5745
Suite 200
Tampa, FL 33607
Comments:
City of2ephyr�ills Permit#18979/18983/19065/19066/19067/19068, Hfdden River Phase 9A PB 74 Pg101 Lot41,105,106,107,
and �
Silverado Ranch Phase 2,3,4,PB 73, Pg 59, Block 03,Lot 93 and Block 04, Lot 03.
Whlle you wlll ba paying your bill wlth Passo County Oevelopment Services,the full amount of the credit card ore-check fe¢s,NOTshown ebove,is cnlle�ted by
Ftrst Billing pByment servitts.
MyReports/reports//PRODUCTION/PASCO/ReceiptPOS V5.rpt 2/14/2018 Page 1 of 1
\
Jacqueline,Boge�
From: OPC Engineering <opcengineering a"(,�")mail.wrec.net>
Sent: Monday, February 26, 2018 10:14 AM
To: Jacqueline Boges
Subject: Re: permanent power request to be released
Thank you
---- Original Message----
From: "Jacqueline Boges" <jboges@ci.zephyrhills.fl.us>
Sent: 2/26l2018 9:35:49.AM
To: "opcengineering@wrec.net" <apcengineering@wrec.net>
Subject:permanent power rec�uest to be released
Hello, �
Jackie,here in the City of Zephyrhills could you please release permanent power for the address 318b Moulden
hallow Dr(hidden river subdivision) single family new horne bp#19068.
I need to have acknowledgment receipt af this request for the pernut file .
Thank you so much and have a great day!
x
dackle Bo9es
8�'3-780-0020 ext�513
"A rule I have had for years is:to treat the Lord Jesus Christ as a personal friend.His is not a creed,a mere doc#rine,but it is Ne
Himself we have"Dwight L.Moody
Florida has a very broad publa.c records law. Electranic cammunications regarding most City
of Zephyrhi.11s business are public records and available upon request. Your e-mail
communi.cations may therefare 6e subject ta public disclosure. Sf you reeeived this message in
error, please da not read, forward, copy, e�c. and delete immeda.ately.
z
Jacqueline.Boges
From: OPC Engineering <opcengineering@mail.wrec.net>
Sent: Tuesday, January 9, 2018 4:56 PM
To: Jacqueline Boges
Subject: Re: release need for tug 3186 Moulden Hollow
Hello Jackie, / �
. �, �°�,�`P� �
Thank you for the release.
Have a great day.
Melissa
---- Original Message----
From: "Jacqueline Boges" <jboges@ci.zephyrhills.fl.us>
Sent: 1/9/2018 4:24:47 PM
To: "opcengineering@wrec.net" <opcengineering@wrec.net>
Subject: release need for tug 3186 Moulden Hollow
Hello my.name is Jackie I work for the City of Zephyrhills and I need a release for a Tug inspection that was
done today. Could you release tug inspection for 3186 Moulden Hollow Dr(Hidden River subdivision)
bp#19068. •
Thank you
Could you send email acknowledgement indicating you received this release.
Have a great day!
X
dackie Boges
813-780-0020 ext 35>3
"A rule I have had for years is:to treat the Lord Jesus Christ as a personal friend. His is not a creed,a mere doctrine, but it is He
Himself we have." Dwight L.Moody
Florida has a very broad public records law. Electronic communications regarding most City
of Zephyrhills business are public records and available upon request. Your e-mail
communications may therefore be subject to public disclosure. If you received this message in
error, please do not r.ead, forward, copy, etc. and delete immediately.
t
1
Jacquelis�e Boges
From: Jacqueline Boges
Sent: Tuesday, January 9, 2018 4:25 PM
To: 'opcengineering@wrec.neY
Subject: release need for tug 3186 Moulden Hollow
Hello my name is Jackie I work for the City of Zephyrhilis and I need a release for a Tug inspection that was done today.
Could you release tug inspection for 3186 Moulden Hollow Dr(Hidden River subdivision) bp#19068.
Thank you
Could you send email acknowledgement indicating you received this release.
Have a great day!
<e d �
I
.�a, ' ,�
� ' I
�
`=` _;�r� �;�:.
dackie Boges - -
813-780-0020 cxt 3�13 '
"A rule I have had for years is:to treat the Lord Jesus Christ as a personal friend. His is not a creed, a mere doctrine, but it is He
I� Himself we have." Dwight L. Moody
' Florida has a ver broad ublic records law. Electronic communications re ardin mo
Y p g g st City
of Zephyrhills business are public records and available upon request. Your e-mail
communications may therefore be subject to public disclosure. If you received this message in
error, please do not read, forward, copy, etc. and delete immediately.
''
II
�
�
. . ' lQ�o _-
' � ';�.,ss1�fIIHuy - '.
s��� 4„�� �'�., -
,��;
� �L.-'!�_�i'v'=_-�-.'ev.
, :'��^^: --��t=.
, -
��s��
•,`
.a__ ..,,�,':
;.;,L--,-�._..�--_ ."r'
City of Zephyrhills
BUILDING PLAN REVIEW COIVTMENTS
Contractor/Homeowner: �� � �� ;n�,�,� �
Date Received: �� _ ��� `7
Site: 3 � t�� /�1�,�;1 �.� /7�ll(�?;��
i F
Pernut Type: I�p �, ��—S �
Approved w/no comments:❑ Approved w/the below coxnments: I� Denied w/the below comments: ❑
- �� �r�CGL�
This comment sheet shall be kept with the permit and/or plans.
�p� �'�
Kal ' S ' —Plans Examiner Date Contractor and/or Homeowner
(Required when comments are present)
i
�
1
Lennar Homes-3186 Moulden Hollow Dr 2,005 sq ft
o umn
SQ. FEET PRICE
MAIN OR LIVING: 2,005 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 225,863.25
FEE SHEET $ 866.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 963.32
ELECTRICAL: $ 194.85
' PLUMBING: $ 129.90
MECHANICAL: $ 90.93
SUB-TOTAL $ 1,379.00
TOTAL $ 1,379.00
- SEWER: $ 2,010.00
WATER: $ 641.00
IRRIGATION: $ -
TOTAL: $ 2,651.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES _
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 5,057.13
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 14,334.97
� 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received Phone Contact for Permitting '813 363 _ 2891
1 1 1 1 1 1 1 1 1 1 1 1 1
Owner's Name Lennar Homes,LLC, �� Owner Phone Number 813.574.5700
Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number
Fee Simple Titleholder Name N�`4 Owner Phone Number
, .
Fee Simple Titleholder Address N/A
JOBADDRESS 3186 Moulden Hollow Drive �or# 1060
SUBDIVISION Hidden River Fhase One A pqRCELID# 24-26-21-0060-00000-1060
(OBTAINED'FROM PROPERTY TAX NOTICE)
WORK PROPOSED 11./ II NEW CONSTR B ADD/ALT � 'SIGN Q � DEMOLISH
� INSTALL REPAIR
PROPOSED USE � " SFR Q COMM .� OTHER
TYPE OF CONSTRUCTION � BLOCK Q FRAME 0 STEEL Q
DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence
BUILDING SIZE U/R SF �a00 SQ FOOTAGE 1555 HEIGHT � StOI'�/
I�BUILDING � �O �,!} VALUATION OF TOTAL CONSTRUCTION
7
�I�/ 'ELECTRICAL $ � PROGRESS ENERGY Q W.R.E.C.
' � ` AMP SERVICE
�PLUMBING $ � � �� ��
II�/ IMECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
7� f
QGAS � ROOFING Q SPECIALl'Y � OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA �YES �10
u
BUILDER COMPANY Lennar Homes,LLC
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address 4600 W. ress St.Ste.200,Tampa,FL 33607 License# CGC1518166
ELECTRICIAN ~ COMPANY Edmonson Electric, �f1C.
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address 1034 Skipper Road, Tampa, FL 33613 �icense# EC13005408
PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGfVATURE REGISTERED Y/ N FEE CURRE� Y/N
Address P.O. Box 5308, Bayonet, FL 34674-5308 �icense# CFC042998
MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc _
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address P•O. Box 308, Bayonet, FL 34674-5308 �icense# CAC058062
OTHER COMPANY
SIGNATURE REGISI'ERED Y/ N FEE CURRE� Y/N
aadress 4211 Shoal Line Blvd, Spring Hill, FL 34607 �icense# CCC057991
� i � � � � � � � � � � � � � � � � � � � � � i � i � � � � � � � � � � � � � � � � � � � i � � � � � i � � o � � � � � � � � � � � i
RESIDENTIAL Attach(2)Plot Plans;.(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects -
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans. .
"""*PROPERTY SURVEY.required for all NEW construction.
. .
Directions:•
Fill out application completely. -
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is requlred. (A/C upgrades over$7500)
*" Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers � Service Upgrades A/C Fences(PIoUSurvey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
- ���i ...__
k
(
�
I . . ' . .
(
NOTICE OF DEED RESTRICTIONS: The undersigned unders#ands that this permit may be subject ta;"deed" restrictions°
which may be more restricfiive than Caunty regulations. `fhe undersigned assumes respansibility far campliance wi#h any
applicable deed restrictions. I''
UNLICENSED CONTRACTORS AND CONTRACTOR'�RESPQNSlBlLITIES: !f the owner has hired a contractor or
contractars to underEake wark, they may be required to be licensed in accordance with state and local regula#ians. If the
contractor is not licensed as required by law, both the owner and contractar may be cited for a misdemeanor violation
under state law. If the owner oc irttended contractor are uncertain as fo what licensing requirements may apply for the
intended work, they are advised�to contact the Pasco County Building Inspection Division--Licensing 5ection at 727-847-
8009. �Furthermore, if the owner has hired a contractar or contractors,. he is advised to have the contractor(s} sign
portions af the "contractor Blockn af this applicafian for which they wi(1 be responsible. lf you, as #he owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasca
County. i
TRANSPORTATION IMPACT/UTIL171ES IMPACl"AND RESO,URCE RECCIVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recoveryi Fees may apply ta fihe canstruction of new buildings, change ot
use in existing buildings, or expansian of existing buildings, as speci�ed in Pasca County Ordinance number 89-07 and
90-07, as amended. The undersigned alsa understands, that such fees, as may be due, will be.identified at the time�of
permitting. lt is furkher understood that Trarispartation lri�pact Fees and Resource Recovery Fees must be paid.prior ta
receiving a "certificate of occupancy" or final power release. If the project daes nat invalve a certificate of occupancy or
final power release, the fees must be paid prior to permifi issuance. F'urthermore, if Pasco County Water/�ewer lmpact
fees are due,they musfi be paid priar to permit issttance tn accordance with applicabfe Fasco County.ordinances.
CONSTRUCTIO.N LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I
certify that I, the appEicartt, have been provided with ;a capy of the "Florida Construction Lien C.aw—=Homeawner's
Protection Guide" prepared by the.Flarida D'epartment of Agriculture and Cansumer Affairs. If the applicant is sameone
other than the"owner", ! certify..that! have obtained a copy of the above described document and promise in good faith to
deliver it ta the"owner"�priar ta.commencement. � -
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with ai[ app(icable laws regulating construction, zaning and land development. Applicafiion is
hereby made to abtain a permit to do wark and installation as indicated. ' I certify,that no work or installation has
commenced prior to issuance af a permit and that all,uvork wil! be performed to meet'standards of all laws regulating
eonstruction, County and City cQdes, zoning regulafions, and land development regulations in the jurisdiction. I a(so
certify tliat I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify wliat'actions 1 must take to belin,cornpliance. Such agencies include but are nat limited to;
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands;WaterlUVastewater Trea#rnent. !
- Sauthwest Fiorida UVater Management Dis#rict-Wells, Cypress Bayheads, Wetland Areas, Aftering
Watercourses. i
- Arr�y Corps af Er�gineers-SeawaJls, Docks, tUavigable Waterways.
- Department af Health & Rehabilitative Seiices/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- tJS Environmentai Protection Agency-Rsbestos abatement.
Federal Aviatian Authority-Runways. i
I understand that.the following restrictipns apply to fhe use of fill:
- Use of fill is not allawed in Flood Zone"V" unless expressly permitted. ,
- !f the fill material .is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating voiume" wi(I be submifted at time of permitting which`is prepared by a professianai engineer .
licensed by the State of Florida. �
- ]f the fiEi material is ta be used in Flood Zo�e "A" in cannection with a,permitted building using stem wall
constructibn, I certify that fill will be used only to fill#he area within the stem wall.
- lf fill material is ta be used in any ar�a, ! !certify fihat uss of such fil! will not adversely affect adjacent
properties. if use af fill is found to adverseiy�aifec# adjacent properties, the owner may be cited for vioiating
the canditions of the building permit issued under the a#tached permit application,.for lots less than one (1)
acre vuhich are elevated by f311,,an engineered Edrainage plan is required. '
Ifi I am the AGENT FOR THE OWNER, I pramise in good#faith to inform the awner af the permitting conditions set forth in
this a�davit prior fio commencing construction. f underst�and that a separate permit may be required far electrica! wark,
plumbing; signs, weils, paols, air conditioning, gas, or pther instaliations nat specifica(iy inciuded.in the application. A
permi# issued shall be construed to be a license to proce�d with the wcark and not as�authority to violate, cancel, al#er, or
set aside any provisions of the technical codes, nor sha3i issuance of a permit prevent the Buildirtg,flfficial from thereafter
requiring a carrectian of errors in plans, cons#ructian or violations of any codes. Every permif issued shall become invalid
un{ess the work authorized by such permit.is commenced vuithin six months of permit issuance, or if work authoriaed by
filie permit is suspended ar abandoned for a period of six(6} manths after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period no#to exceed ninety (90) days and will demonstrate
justifiiable cause for the e�ctension. [f work ceases far ninety{90)consecutive days,the jab is considered abandaned.
,
WARNlNG TO OWNEf�. YOUR FAl�URE TO REC�RD A NOTiCE QE COHtIMENCEMENT MAY RESULT 1N YOUR
pAYING TWICE FOR 1MPROVEMENTS TO YOUR PRt)PERTY. IF YOU INTEND 70 OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY'BEFORE RECORpING.YOUR NOTICE OF COMMENCEMENT.
FLORIDR JURAT(F:S.917:43} , , ,
�
OWNER OR AGENT _ ,,,,,_,,,�_,,,,,_,,, _ CONTRACTOR �
Sutascribed and swom to{ar aFftrme before me this SuEiscribed and sworn to r a �rmed}before me this _
v°-uG-c-�� py paul Sweene _ • _ �e�o��-�� by Bat Sweene - ' " ^ -
Who is/are ersonall knawri to e or Who is/are ersonall nawn to me or
as idet�tification. as identification.
�� i .
�r� Notary Public � iVotary Public
, , ,
Commission No. FF98537 Commission No. FF98537 ' '
Elissa IvI.Holleran ' �- Elissa M.Holleran �
' Name of NotaN tvped,printed or stamped Name of Notary typed,printed or stamped
_ .�..�.�.
�I�I�M�.N�19��W' - ,il �I��,kli��I'AI��W .
y��rsar��anE�l.���heae� �r�un"�u'tanpi��Pabaal�' 1
j ��a��r�������
��4,�1dIt�����fF�� , �, . �., e+�dwla�atT,»�P,�eivo�.�dd�11�PU ,
",; . �, �drdl�ItNTkayF�a'�44+9H,�118C47�9,7tQ1 � - -
i
� I
I _ _
__�
� �,
'i
� = PASCC} COUf�TY, F�t�RtDA
,
. .. Permtt No. d ��g
Date Permi�ted ,� --/____7-1.?�^
Builder NametOwner Name �VtLzh'�'�Yne �.[.-� Cantroi#
Gounty Parcei No. ' -'�-2-�-UDqO �-�O�Z� SubDiv: �Sp((,{'p���2y-�
Address/Lacation ��,,,_8 (o l�.n{�(,,�CitP� �t�a�c�� __
ClassiflcatfoM"ype of Usa �i�tP �"�''''t��-f__
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Z�OC�J
Exempt []Yes [] Na Ho�nr Determined
� lmpact Fee Amount $. v�- ��232• Zone No. TAZ:
SCHt10L IlU1PAGT FEE
Account (056) Singfe-Family Detached Nouse Amount $ �1��lo• 2�3
(057) Mobtle Nome
(058) Other Residential
123) Gollectlan Fee
Exempt []Yes ❑No How Determ(ned
PARKS AND RECREATit3N FEE
Land Account Land Credit Land Totat
Recreation Account Recreatian Credlt �Recreatton Tota!
Zone TOTAL AMOUNT $ Z(�`����
Exempt (�Yes ❑ Na Haw Determined
LIBRARY FEE
�and Accaunt Land Credit Land Totat
Facillty Accoun# Faciitty Cred(t Faciitty Total
Exempt ❑Yes ❑ No How Determ{ned Tota(Amou���=-
RESOURCE FEE ERU
TOTAL AMOUNT �
Praparad By ' Checked By
NO CERTtFiCATE OF OCCUFANCY WILL BE ISSUED OR FIMAL 1NSPECTION
PERFQRMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
SEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING lJFFICE OF PASCO COUN'TY
Acknowladgement befow doas not impiy acceptance of concurrence,but sfmpty racelpt of a aapy of thfs form,piacing
, the buliding parmit ownar on notice of this assessment and thQ condittons ot paymant ior same.
DATE RECEIVED BY
RECEfPT NO. DATE BY
;
. � I
i
Single Family Dwelling
Plan Review Comments
1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan.
2. Lots shall be graded to coinply with R401.3 of the F.B.C.
3. Compaction test required if 24" or more of fill dirt is brought in at any one place. '
4. Tie in survey required before pouring concrete.
5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have
expansion material.
6. All setbacks shall be met.
, 7. All property markers shall be uncovered and marked at time of first inspection.
8. All A.D.A. requirements shall be met.
9. No electric,plumbing,mechanical, or framing shall be covered without an inspection and
approval first.
10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).
11. Appliances shall not be installed in a location where subject to mechanical damage unless
protected by approved barriers. M303.4 of the F.B.0
12. Water heaters shall comply with section P607.3 of the F.B.C.
13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1
14. Return air in all bedrooms. F.B.C. M1620.4
15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C.
16. All glazing requirements are to be in accordance with R308.4 of the F.B.C.
17. All means of egress are to be in accordance with R311 of the F.B.C.
18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C.
19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker.
20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating
or appliances or an attached garage. They shall be installed in accordance with the F.B.C.
21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all
underground plumbing and electric.
22. A112008 N.E.C. Codes will be enforced.
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0
24. In accordance with the Land Development Code, lots shall be sodded before final at least 10
feet around the structure.
25 A COpy of the ener,gv cacls shall be with perntit at all tinies
26. Cony of fnal insulation report shall be provided with ne�•n:it befoYe�na�
� F.F.E.-Finished Floor Elevation
F.B.C-Florida Building Code 5�'Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008)
: • _ E �.� ' � I V�
� 4� ,�''� � � � 1 .
. � � ,.��.....,......y...._....�_, '� ' ,�� F� ' �
.,... ..�.. _ ....:;..� • 1, � ' �, '
.,,..._,.......,.._.r.. _,�.....�.. � .:._....,, ...:_ .�...�.� _•� ,I
r ...w. ;r��� , .
� � : .�_
; ` '��,,, ` � . :, � ' , �.��,� -�..._ II
- , �,� r,��'. �� `t ,�? _ ' '�FF�. � �. "
� ,:= ���� . � �1 ��.. �: , ��: '� .�Q� r ;► I
• ,�-� �� - � � -� �� ` �� rs.�f t �'� . ,�,,�� � �� .
v -�' �� � '� } L i� ,� .� ``�,� � � �,�-_�.
�'%•'' ��� � �1 � .�� �� ��:.. t � . F ' � "`.,� "�•...�►�� l
�.. . , . �. �"' , � �� 7�.s� '� !
-�� � , � �e:��► � � �► , - `� ti� � � ''�`� ~7
; �� � � '� ,,;�• , � �� ,� ��
. 1 ,�� � � :'�� � .� �
r, � . �. �-� , .. :�:-- �.�; � � f� ��..
+� � . 1 � ���.i.. i� ��.. A. � �,�; � . � � �
F- j -. l�� �° �'��1 �' -� , ., +� �a. i `�,, �ti r� f"��`•..� �.
� � �� � � A� . - - E� 1 -�,�o �.;� '�, � � ,
! � � �� , �,. FP E!. �.�� p �: ,� �A'�r
' �,� �.� `�` '' . .''' i �.. �.� �ti r �� �, ��= �
.. ,� ` ,;.� • ' � ,� �
;i n ,,. • E �� , ' � � . ~� � � '� '�$
' �.�,,, � .�� �.�s .' �'��1 '��� t�` . ` � '���� �'"` '
�.' -��..� „ . � � - �r� .r � +.. .
,: �`• , ,= � ' � ' �:
•--�,r�,� ` �a 1, � 1 .1 _ � � �,�, �.. � '�.,� ��
FF�1. ' �� � 73:�0 1 -'���� 1' ;� .�'`�:,r.r"ic � , ti: � �
r '' '�'� .ti 1 � '� '� i ��`'�
� �y� ! �$. � � A O 1 � �� ..�"'r/' �FF.txl. l� `� *�.
i A � ' 7SA� ' � � �� � ' 1 �'�� .+1 '�^ ��+'�.5/ �t� �� F��. �`'
.�...�. - I �1 '� � _ � �11 ,.� �'' '� t � i• rz;�
� ..,._� � �� �� �� 1� ��,;,,.r �. . 1 ` • ��� 1 �1 i "
i■�s �r,sN r,, ,1�q�1 �,�.� , .��
�' .. � ' ' �; �x'i�,r`��+ �� �' �l��e�rn .� 1 � ��ti', . f 1�
� � t�. .
�
PI�OT PLAN NOT A BOUNDARYLSURVEY �EC" 24 , TWP. �� S, RNG.'2� E.
�OT 106 ' aEnr�Nc ens�s:
HIDDEN RIVER PHASE ONE A NORTF# BOUNOARY OF SUBJECT PLA7 �tG S 85'40'�a` E
PASCO COUNIY, FLORlDA_ �T '(};�g $�}RttEY 15 StT$SECZ TQ ANY FAC75 MAT
�� NAY 8E D15CCd5EU BY A FUIt ANp ACCURA7E
71TLE SEARCH. ALSO SUBJECT TO SETBACKS.
PRE�lMtldARY DRAWlNG: Eas�ENTs nwn RES'rn�cnoius o� REcoRn.
7HIS AtAN SS FOR PERhi1iSINCi PURPOSES o
UY4Y, N07 F4R CONSTRUCTICNV. �IERIFY h UNOERGRWNp FQOTER, SfE�.t WAtt, AttD
ALL CIIMEN51C1N5 BfFQRE ANY CONSTRUCTION. � uNpEttc,�WND ununEs artE No7 �pCaTED C�t
� SHOWN_
LEGENLl: ^ 00 NOT SCALE 11i�5 PRINT. O1ktEN51CMi5 ANO
�+ = PROPOSfO DRAINAGE FLOW � NOTES TAKE PREFERENCE_
{Op.00}- = PROPOSEO GRAOE N
E-00.00 = EwSnNG GRAOE cEftraN UATA sKOwH KEr�Eoaz BaSEo o�
ENpNEERING PLANS PROVi0E0 BY CUENT.
STF?t.lC71lRE TIES SHQwN HEftEOi� DENOTES
ldEASURENEAtT FROit F�2Y BOARUS%f0t3NDA'iCQN
TO PROPERTY UNE.
� = 10' ORAiPNGE/UitUTY E1lSEtAEM
/ ...
= 70' DRNNAGE EASE6IENT
� �+� 7 1� LOT t05
� � i,�9
t/ ��"f oo-=-_- / �--� S ,
"i�V�►'C`��c�, �` �g-a�.. :;� � lSpg�. �
V �`� _ �` � - M/, � ,04::: �7p�Q,.
�� � M '_1`.- J .
O -.�� - -�•--` .tih.
/ 1-� h=. �'�
� / * ��� h
r•+:.' � '/ \
v ��d„>. LOT 106 �
'�o. j�. �¢ �, "
`Ql S te„'�'r„�-9` h�,y�'0v
QCP �D,.�,4. � c. 3°9 '
•�A� c� �' -'-
. :. � p.� +�."QT ."A
2 � � \ `Sq� � 4r o-0o c
as � �. O� -,
a�,� ."G�, �ss}4r �' �
oo_o, � s3.
�•
� � G
_ S'�t� s�\ .�,�
��. f# ' 1
OW LOT AREA CALGULA'iIONS 4Q'� \ � �
LOT a 8195.26 Sq. F'f. �y \ �''. ''•:Tv �
UVING AREA 1556 SO. FT.
ry� '`�s' LOT 329
fNiRY � 40 St). FT_ �j� - �� -
GARAGE = 406 50. FT_
COVEt2E0 LANA1 N/A SU. FT_ LOT 10� �O• \.
PA3t0 � 23 5Q. � � \
CQNC. ORIVE = 4� SO. F'T , \
A/C �6c CO��C PAD = 9 SQ. FT
PRIYATE SiDEWAIK = 28 SO. fT_ �
JiAPERVtOUS - 31 z ^
� '2526 SQ. �. o
SOp - 5669 50. FT y,
OFF LOT AREA CAL.CULATIOIdS � -
RIqiT QF 1YAY - 599.�4 $p. �_ � \
� QRt1l� APAON = t� SQ. F7_ ,"
PUB!!G 9DEWAl.Ic = ZO& SQ. FT_
_5pp � 249 So. FT, LOT 330
TCtTALS N���
aRea = s�sa.so so. Fr. �ar atnaNc �E = n
ORIYEWAY = 608 Sq,.�. PROPOSED PAQ ELEVATION = N/A
90EWALK � 23a SQ. f7. fRONT SETBACK = 20'
Spp = 5918 S0. FT. 3DE SETBACK = Sd•
REM SETBApf = t0'
CURVE DATA
cu�r i aao2vs a.ac cHa�o a�+�c a�.Tn pROPQSED-
cs> >30.00' sz.ss' s2.00• r+ 3o-n•ot` � zsoa•ze' LOWEST FLOOR ELEI/ATIONS:
csz � �3a.00' s�.�x' s�.3s• N 53't3'09'E zrax3e-
CtQ1 I 240.00� 96.65' 96.q0' S 34'17'O)"l+t 2SOC'25" �.(�N(a /�1R�1: 7�_$r'J�
GARAGE AREA:
DESCRIPTIl7N: ELEVA710NS REFERENCED TO
�Qi` ]06. MAP OR PLAT EN31TlEQ "H@DEN RNER PNASE ONE A", NATIONAL GEOOEf1C VERTlCAL
AS RECORDED tN PLAT 800K 074, PAGES t01 THROUGH 12i, DATUM 4� `1929. MEAN SEA
OF THE PUBLIC RECORDS OF PASCO COUNTY,. FLORIDA. LEVEC= 00.00 Ff.
APPARENT FL000 HAZARD ZONE: "X" COMMUNITIf PANEL NO. 120230 046Q D EFFECTIVE DATE: 9/30/1992
Froyeci Atumber. _ Squore Feet= $19536 ± ' lEMNXR HOMES
C'cG�NO: •
[C)= CALCULA?ED DATA, (D)= DEED pATA,�(M)= MEASURED DATA, (P)= PLAT DATA, g= CEN7ERLINE. A/C= AIR COWO171pNER, B/C= BACK OF CURB. G/S=
CO.tG4c7E SLA9. Gv= GH4:2D. t�-t8= CH{3.40 BEARtNG. CIF= GHAiFt UNK FENCE C4t+tC= C4NCR£3E. COY.= COLEREQ.-Ef,k?d=£OG£ 4� PAVE�+tEt17. ESµ'T= EASEI�IEHT,
FjC= FEyCc CO�v.R, �CM= FOUt�6 CO�SCRETE t�tONUMEtVT, FlP= FOUND tF20N PiPE. FlR= POUNp tRQN RO�,�FJiBct?= r-OUN�`J'bSAR dc DISK, FPP= FWND PlNdiED
PIPE. I.FE= LOY4E57 FLOOe2 ELEVATIOV, MAS.= MASONRY, OR= OFFlpAl. RECORO BOOK, P�� PLAT BOOK,.�Pp'=F'EiklS'M'.G`N�CC:TJTROL POINT, PRM= PERYANENT
r` `'_
REFERENCE MO.\UMEN7, R/W= F21G'iT OF wAY, R= RAD1U5. SIR=5E7 7/2' IRON ROD dc CAP No. 4493. SN&D=�w-� NAIk-�=DISK,��E'!liE= TE1dPQRARY BENCHIIARK,
t3 = Ui1Cl7Y FOLE_ W = tTtOdO FENCE. R = RADIAE. �=�r=�i,��
JOHPI R.BEACH 8c ASSfJC1ATE5,INC. Orawn By: ry� �.� ,��-4- -� " �
_r- JMYS tih /"'\^ � a ''� � +
T StiR�YORS AND MAS'PERS Checked Sy-
9ii YIcST ST_ PEiER56URG DRiVE -;"` _
ONE OIDSMAR, fl.ORIOA 3t677 3� ` � - "r�;} :i"'� ;
wAY (g13) 85a—t276 FAx (813) 855-8370 `-'CO1e: �,_30, :j -_ ~ " ' n^- 'S, *
HOi VAUD K't3H0UT THE StGNATURE AND paie- PLOT PUW 9/OS/20i7 GH ��� �" �-n �
� �1 1� �dl
iHc 0:21GINA1. RAISED SEAL Oi A FLORIDA JO . BFACH"� r`�"_ "-'��^ .,�
UCtNS:D SUR�YOr2 AND MAPPER RIDA Gr I.AND'S!JRV�YG`R ��2984 !.B 4493
Rerisioas REYISED PtR DESCRiPStt}N 3/t3f T7 JBS , --_ . -
T' y„ � � . .
FORM R405-2014
FLORIDA ENERGY EFFICIENGY CODE FCIR BUILDING CONSTRUCTION
Florida Department af Business and Professional F2egulation - Residential PerFormance Method
Project Name: 1551 B sf ADS Builder Name: Lennar Homes
street: 3186 Mouldean Hallow Drive Permit Office: �1 of Zephyrhills
Gity,S#ate,Z'sp: ,FL, Permit Num6er ��j(,�(�?�j
Owner. Lennar Homes Jurisdiction: 611600
pesign Location: Fl.,Tampa County Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1492.0 sqft.) Insulation Area
2. S9ngte famity ar mu(tip3e family Single-family a.Cancrete Block-Int lnsul,E�cterior R=4.1 9 976A0 ft2
b.Frame-Wood,Adjacent R=11.0 316.00 ft
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Namber of Bedraoms 3 d•NIA R= �z
5. Is this a worst case? Yes 10.Ceiling Types (1555.0 sqft.) Insulation Area Z
a.Under Attic(Vented) R=30.0 1555.00 ft
6. Ganditioned floor area abave grade(ft�} 1555 b.NtA R= ft2
Conditioned floor area below grade(ft�) 0 c.N/A R= ft22
11.Ducts R 1�
7 Windows(1d4.3 sqft.} Description Area a.Sup:Attic,Ret:Main,AH:Main 6 312
a. U-Factor Dbl, U=0.54 55.00 ftz
SHGG: SHGG=0.31
b. U-Factor. Dbl,U=0.56 33.33 ft2 �2•Cao(ing systems kBtuthr Efficiency
SHGC: SHGC=0.32 a.Central Unit 25.2 SEER:16A0
c. U-Factor� Dbl,U=0.56 16.0�ft2
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor N!A ft2 a.Electric Heat Pump 21.8 HSPF:8.50
SNGC:
Area Weighted Average Overhang Depth: 1.319 ft.
Area Weighted Average SHGC: 0.309 14.Hot water systems
a.Elecfric Cap:40 gallons
S. FloorTypes (1555.0 sqft.) Insulation Area EF•0.950
a.Siab-On-Grade Edge Insulation R=4.Q 1555.fl0 ftz b. Conservation features
b.N!A R= �2 None
c.N/A R= �� 15.Credits Pstat
Glass/Floor Area: 0.067 Total Proposed Modified Laads: 50.84 �w��
TQta!Saseline Loads: 50.87
/"\
1 hereby certify that fhe p[ans and spec[fcations covered by Review of the plans and ��'fi�.��'r��.� .-
this calculation are in compliance with the Florida Energy specifications cavered by this �;;�r ,�. '-_•;;y O
c_ �, � '
Gode. calculation indicates compliance . �'Q'+sr�,, ' `==����.�`�.Ys+
with the Flarida Energy Code. •I••� rn,���`r%:=y=�:�',•;�`ti,��
PREPARED BY: �7(a'VPT{��I�IC� Before construction is completed c�'� � �`�' ""
DATE. this building will be inspected foc � '"�1`���C��-- �
compliance with Secfion 553.908 ' *., �"� = : �.,
I hereb certi that this buildin as desi ned,is in com liance Flarida Statutes. �
Y fY 9, 9 P �?'�,� '._-:. ;,�c�� .'
with the Flarida Energy Code. � aLi'WE`C�' :
C?WNERlAGENT: � BUILDING FFICIAL:
DATE: � _ DATE:
- Campliance requ9res cerEificatian by the air handler anit manufacturer that the air handler enclosure quaEifies as
certified factory-sealed in accordance with R403.2.2.1. `
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4,4.1 and an envelope leakage
test repart in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to autdoors,
tested in accordance with Section 803 af RESNET Standards,is not greater than 0.080 Qn for whate house.
9/13/2017 12:05 PM EnergyGaugeO USA-F'IaRes2014 Sectian R405.4.1 Compliant Software Page 1 of 4
� . . . .
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential PerFormance Method
Project Name: 1551 B sf ADS Builder Name: Lennar Homes
street: 3186 Moulden Hollow Drive Permit office: City of Zephyrhills
City,State,Zip: ,FL, Permit Number:
Owner. Lennar Homes Jurisdiction: 611600
Design Location: �FL,Tampa County:. Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1492.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ftz
b.Frame-Wood,Adjacent R=11.0 316.00 ftZ
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ftZ
5. Is this a worst case? Yes 10.Ceiling Types (1555.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 1555.00 ft'
6. Conditioned floor area above grade(ftz) 1555 b.N/A R= ftZ
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ftZ
7 Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311 I
a. U-Factor Dbl,U=0.54 55.00 ftZ
SHGC: SHGC=0.31
b. U-Factor Dbl,U=0.56 33.33 ftz 12-Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 25.2 SEER:16.00
c. U-Factor: Dbl,U=0.56 16.00 ftz
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftZ a.Electric Heat Pump 21.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.319 ft.
Area Weighted Average SHGC: 0.309 14.Hot water systems
a.Electric Cap:40 gallons
8. FloorTypes (1555.0 sqft.) Insulation Area EF 0.950
a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ftZ b. Conservation features
b.N/A R= ftZ None
z
c. A R= ft 15.Credits Pstat �
Glass/Floor Area: 0.067 Total Proposed Modified Loads: 50.84 p A C C I
Total Baseline Loads: 50.87 r/`'1�7�7
I hereby certify that the plans and specifications covered by Review of the plans and Tk�.E;S� .
this calculation are in compliance with the Florida Energy ' specifications covered by this -���� _ �rQO ,
Code. calculation indicates compliance '��±�,,,�''� `'-���;��K+ .
�" with the Florida Energy Code. �+ �irrr`,�%�.�;:::�.,;.�i�`•`ti,'r0 ,
PREPARED BY: �2G�'1/� f��j'I�YC Before construction is completed ' ''y �"°`-"'" ���
DATE. this buildin will be ins ected for ~
9 P C7 �`_1�'�j �: ;� .
compliance with Section 553.908 ' * -�~'� ' :_ _�
I hereby certify that this building,as designed, is in compliance Florida Statutes. .� , , �,�
with the Florida Energy Code. G'Otj yyj,;:�� _
OWNER/AGENT: BUILDINC�OFFICIAL:
DATE. DATE: �l��L���
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.080 Qn for whole house.
9/13/2017 12:05 PM EnergyGaugeOO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
i
, , , . • • .
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1551 B sf ADS Builder Name: Lennar Homes
street: 3186 Moulden Hollow Drive Permit office: City of Zephyrhills
City,State,Zip: ,FL, Permit Number�
Owner. Lennar Homes Jurisdiction: 611600 -
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1492.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ftz
b.Frame-Wood,Adjacent R=11.0 316.00 ft2
3. Number of units,if multiple family 1 c.N/A R= �_
4. Number of Bedrooms 3 d.N/A R= �:
5. Is this a worst case? Yes 10.Ceiling Types (1555.0 sqft.) Insulation Area 2
a.Under Attic(Vented) R=30.0 1555.00 ft
6. Conditioned floor area above grade(ft� 1555 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ
11.Ducts R ftZ
7. Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311
a. U-Factor� Dbl,U=0.54 55.00 ft2
SHGC: SHGC=0.31
b. U-Factor Dbl,U=0.56 33.33 ftZ 12•Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 25.2 SEER:16.00
c. U-Factor Dbl,U=0.56 16.00 ftZ
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftZ a.Electric Heat Pump 21.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.319 ft.
Area Weighted Average SHGC: 0.309 14.Hot water systems
a.Electric Cap:40 gallons
8. Floor Types (1555.0 sqft.) Insulation Area EF 0.950
a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ftZ b. Conservation features
b.N/A R= ftZ None
c.N/A R= �Z 15.Credits Pstat
Glass/Floor Area: 0.067 Total Proposed Modified Loads: 50.84 pASS �
Total Baseline Loads: 50.87
I hereby certify that the plans and specifications covered by Review of the plans and :a�'S�:S�':q�,� --._
this calculation are in compliance with the Florida Energy specifications covered by this ��S' ,, ' __-�_� O .
Code. calculation indicates compliance ���i;,T;'�, `_ '�:``:�.�e+
�" with the Florida Ener Code. �+ iir,i, `�, •,;:::�:•;:+.�` � `
PREPARED BY: �7G�VG f���'(GYG 9Y � ' ;:�;-w;'` 51 p
Before construction is completed ` �
DATE: this buildin will be ins ected for � �`��' , ~ ',i` O
9 P t� � -��ll� �. ;
compliance with Section 553.908 �:, : .-,�. . I
I hereby certify that this building,as designed, is in compliance Florida Statutes. -�C ` ��.t I
with the Florida Energy Code. �D'y�i�'C¢ ,
OWNER/AGENT: BUILDIN OFFICIAL:
DATE. DATE: �- � -
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards,is not greater than 0.080 Qn for whole house.
9/13/2017 12:05 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
� . . .
FORM R405-2014
PROJECT
Title: 1551 B sf ADS Bedrooms: 3 Address Type: Street Address
Building Type: User Conditioned Area: 1555 Lot#
Owner. Lennar Homes Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Lennar Homes Rotate Angle: 45 Street:
Permit Office: Cross Ventilation: County Pasco
Jurisdiction: Whole House Fan: City,State,Zip:
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: 2017
CLIMATE
� IECC Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium
" BLOCKS
Number Name Area Volume
1 Blockl 1555 12440
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated
1 Main 1555 12440 Yes 4 3 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 134 ft 0 1555 ftz �_ 0.3 0 0.7
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
�� # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 1684 ftZ 0 ftZ Medium 0.85 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC �
1 Full attic Vented 300 1555 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 UnderAttic(Vented) Main 30 Blown 1555 ftZ 0.11 Wood ,
9/13/2017 12:05 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
I �
` . , .
FORM R405-2014 .
WALLS
Adjacent Spa� Cavity Width Height Sheathing Framing Solar Below
1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 20 S 160.0 ftZ 0 0.600000 0
2 E=>SE Exterior Concrete Block-Int Insui Main 4.0999 54 8 432.0 ftZ 0 0.600000 0
3 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ftZ 0 0.600000 0
4 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 33 8 264.0 ft2 0 0.600000 0
_ 5 N=>NE Garage Frame-Wood Main 11 19 8 152.0 ft2 0 0.01 0
_6 W=>NW Garage Frame-Wood Main 11 20 6 8 164.0 ftZ 0 0.01 0
7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 � 8 48.0 ftZ 0 0.600000 0
DOORS
# Omt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>NE Insulated Main None .2 3 6 8 20 ft2
2 N=>NE Wood Main None .4 2 8 6 8 17.8 ftZ
WINDOWS
Orientation shown is the entered orientation => chan ed to Worst Case.
/ Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 16.0 ftZ 1 ft 0 in 4 ft 0 in Drapes/blinds None
2 E=>SE 2 Metal Low-E Double Yes 0.54 0.31 16.0 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds None I
3 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 16.0 ftZ 1 ft 0 in 1 ft 0 in Drapes/blinds None
4 S=>SW 7 Metal Low-E Double Yes 0.56 0.32 33.3 ftZ 2 ft 0 in 0 ft 6 in Drapes/blinds None
5 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 23.0 ftZ 1 ft 0 in 1 ft 0 in Drapes/blinds None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 408 ft2 408 ftz 40 ft 8 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EqLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000254 ' 1036.7 56.91 107.03 .1906 5
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump None HSPF:8.5 21.8 kBtu/hr 1 sys#1
9/13/2017 12:05 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
( 1 � � � • + .
FORM R405-2014
COOLING SYSTEM
# System Type � Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 16 25.2 kBtu/hr 756 cfm 0.85 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 60 gal 120 deg None
SOLAR HOT WATER SYSTEM
I FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
/ —Supply— —Return— Air CFM 25 CFM25 HVAC#
�� # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 311 ftZ Main 77.8 ftZ Proposed Qn Main —cfm 124.4 cfm 0.08 0.60 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Coolin Jan Feb Mar A r Ma X Jun Jul Au Se Oct Nov Dec
Heating �Jan �Feb f X Mar �Apr f �May Jun Jul Au9 Sep Oct Nov Dec
Ventin Jan Feb [X Mar A r [ Ma Jun Jul Au Se Oct X Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
9/13/2017 12:05 PM EnergyGaugeOO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 4 of 4
� , . ' ' .
FORM R405-2014 .
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index,the more efficient the home.
„ FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ft2
b.Frame-Wood,Adjacent R=11.0 316.00 ft
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number af Bedrooms 3 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types Insulation Area Z
a.Under Attic(Vented) R=30.0 1555.00 ft
6. Conditioned floor area(ft2) 1555 b.N/A R= ft�
7. Windows'* Description Area c.N/A R= ft�
a. U-Factor: Dbl,U=0.54 55.00 ftz 11.Ducts R ftz
a.Sup:Attic,Ret:Main,AH:Main 6 311
SHGC: SHGC=0.31
b. U-Factor Dbl,U=0.56 33.33 ftZ
SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: Dbl,U=0.56 ' 16.00 ft2 a.Central Unit 25.2 SEER:16.00
SHGC: SHGC=0.28
d. U-Factor N/A �2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 21.8 HSPF:8.50
Area Weighted Average Overhang Depth: 1.319 ft.
Area Weighted Average SHGC: 0.309
8. Floor Types Insulation Area 14.Hot water systems
z a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ft EF:0.95
b.N/A R= ftz
c.N/A R= {�z b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building �- ;��,��.-� -
Construction through the above energy saving features which will be installed (or exceeded) �,�.a� "" `�?2?0, -.
in this home�before final inspection. Otherwise, a new EPL Display Card will be completed y4�",,;;`'� ���;.� ''�,;�.. -
based on installed Code compli t features. � ?ri„�r�%;:"_.'"� '��°s��o_
;:;_-.'%„v,. :x�
�. �.�•,��.. _ ;, t�
Builder Signature. _, Date: 09/14/17 �. :���(�'`_� �
, .*. � �
Address of New Home: Ci /FL Zi '�'
3186 Moulden Hollow Drive tY p�Zephyrhills,FL 33540� ;�G������� :-
'`Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
9/13/2017 12:09 PM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
Buildin Anal S�S Job: 1551BsfADS
g y Date: 9/1312017
Entire House By: Dave
� BAYONET PLUMBING COOLING HEATING
' • - • �
For: Lennar Homes
� - • • • �
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD (°F) 39 16
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7
Dry bulb(°F) 31 91 Infiltration:
Daily range(°F) - 14 ( L ) Method Simplified
Wet bulb(°F) - 77 Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
•
Component Btuh/ftZ Btuh % of load
Walls 5.6 6022 27.8 ��
GleZlllg 30.2 3178 14.7 wa�� nt��o-ation
Doors 23.5 480 2.2
Ceilings 1.3 1950 9.0
Floors 3.7 5815 26.8
Infiltration 1.9 2323 10.7
D ucts 1901 8.8
Fioo�
I� Humldification 0 0 Glazing
Ventilation 0 0 DooCeilings
Adjustments 0
Total 21670 100.0
• •
Component Btuh/ft2 Btuh % of load
' Walls 2.8 2996 15.6 Walls
Glazing 59.1 6224 32.4 Intemal Gains
Doors 18.4 376 2.0
Ceilings 1.7 2697 14.0
Floors 0 0 0
Infiltration 0.4 520 2.7 i • �
Ducts 2200 11.4 - Ducts
Ventilation 0 0 �
Internal gains 4210 21.9 ��azin9
BlOwer 0 0 Infiltration
Adjustments 0 Ceilings
Total 19223 100.0 Other
', Latent Cooling Load= 2870 Btuh
Overall U-value= 0.103 Btuh/ft2-°F
Data entries checked.
�. -�- wrightsoft� 2017-Sep-13 12:11:07
�� Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1
...with CBA27UHE AH's\155181 sf ADS drawn 2ton.rup Calc=MJ8 Front Door faces:NW
,, ; . ' ' . .
Pro ect Summar�� Job: 1551B sf ADS
1 '1 Date: 911312017
Entire House By: Dave
BAYONET PLUMBING COOLING HEATING
' � - • �
For� Lennar Homes
N otes:
� - � • •
, Weather: Tampa International AP, FL, US \
Winter Design Conditions Summer Design Conditions
Outside db 31 °F Outside db 91 °F
Inside db 70 °F Inside db 75 °F
Design TD 39 °F Design TD 16 °F
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 19769 Btuh Structure 17023 Btuh
Ducts 1901 Btuh Ducts 2200 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 21670 Btuh Use rrianufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 19223 Btuh
Method simplitied Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 2479 Btuh
Ducts 391 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft2) 1555 1555 Equipment latent load 2870 Btuh
Volume(ft') 12438 12438 ,
Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 22092 Btuh
Equiv.AVF(cfm) 54 29 Req. total capacity at 0.85 SHR 1.9 ton
'�
Heating Equipment Summary Cooling Equipment Summary
Make Lennox Make Lennox
Trade 14HPX SERIES Trade 14HPX SERIES
Model 14HPX-024230-21 Cond 14HPX-024-230-21
AHRI ref 10258598 Coil CBA27UHE-024-230*++TDR
AHRI ref 10258598
Efficiency 8.5 HSPF Efficiency 13.5 EER, 16 SEER
Heating input Sensible cooling 21420 Btuh
Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh
Temperature rise 25 °F Total cooling 25200 Btuh
Actual air flow 800 cfm Actual air flow 800 cfm
Air flow factor 0.037 cfm/Btuh Air flow factor 0.042 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.87
Capacity balance point= 32°F
Backup: n/a n/a
Input= 0 kW, Output= 0 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
C. "� wrightsoft� 2017-Sep-1312:11:07
�� Right-Suite�Universal 2017 17.0.23 RSU05714 page 1
.with CBA27UHE AH's\1551B1 sf ADS drawn 2ton.rup Calc=MJ8 Front Door faces:NW
. .
� � F < � , .
Manual S Com liance Re ort Job: 1551B sf ADS
p p Date: 9/13/2017
Entire House By: Dave
BAYONET PLUMBING COOLING HEATING
' • - • �
For: Lennar Homes
• • • • �
Design Conditions
Outdoor design DB. 91.3°F Sensible gain: 19223 Btuh Entering coil DB 75.7°F
Outdoor design WB: 77.3°F Latent gain: 2870 Btuh Entering coil WB 62.8°F
Indoor design DB: 75.0°F Total gain: 22092 Btuh
Indoor RH. 50% Estimated airflow: 800 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Lennox Model: 14HPX-024230-21+CBA27UHE-024-230*++TDR
Actual airflow: 800 cfm
Sensible capacity: 21420 Btuh 111% of load
Latent capacity: 3780 Btuh 132% of load
Total capacity: 25200 Btuh 114% of load SHR: 85%
� • �
Design Conditions
Outdoor design DB: 30.8°F Heat loss. 21670 Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer Lennox Model: 14HPX-024-230-21+CBA27UHE-024-230"++TDR
Actual airflow: 800 cfm
Output capacity: 21800 Btuh 101% of load Capacity balance: 32 °F
Supplemental heat required: 0 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer• n/a Model: n/a+n/a
Actual airflow: 800 cfm
Output capacity� 0 kW 0% of load Temp. rise: 0 °F
Meets are all requirements of ACCA Manual S.
... wri htsoft� 2017-Sep-1312:11:07
�, 9 Right-Suite�l Universal 2017 17.0.23 RSU05714 Page 1
� ...with CBA27UHE AH's\1551B1 sfADS drawn 2ton.rup Calc=MJ8 Front Doorfaces:NW
5335 - 8TH STREET
, . (813)780-0020
CERTIFICATE OF OCCUPANCY
Address: 3186 MOULDEN HOLLOW DR Owner: LENNAR HOMES LLC
ZEPHYRHILLS, FL. 4600 WEST CYPRESS ST STE 200
Subdiv: HIDDEN RIVER TAMPA, FL. 33607
Parcel: 24-26-21-0090-00000-1060 Work Type: 101-NEW CONST/SFR
Construction Type: NOT APPLICABLE ❑ Sprinklers ,
Use Classification: NOT APPLICABLE
Permit Number: 19068
Date: 3/ /2018
i ��
ISSUED BY: BUILDI OFFICIAL :
WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE
GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE
-- � �` -`
Jacqueline Boges
To: City of Zephyrhills Support
Subject: RE: Request#201281: How would you rate the support you received?
From:City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com>
Sent:Saturday, March 24, 20181:03 PM
To:Jacqueline Boges<jboges@ci.zephyrhills.fl.us>
Subject: Request#201281: How would you rate the support you received?
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We'd love to hear what you think of our customer service. Please take a moment to answer one simple question by
clicking either link below:
How would you rate the support you received?
Good. I'm satisfied
Bad, I'm unsatisfied
Here's a reminder of what your ticket was about:
... �7 f� .�
�_� � �1�
r TQ Randolph (City of Zephyrhills Support ) �
------j Mar 23, 9.01 AM MST
Mapping Complete. 889145-2985959, SO #655025
Best Regards,
TQ� FATHOM Support
� "� ` TQ Randolph (City of Zephyrhills Support )
p( � �
` �L Mar 1�, 9 50 AM MST
Hi Jacqueline,
Account 889145-2985959 has been established for this location and is pending mapping by
1