Loading...
HomeMy WebLinkAbout17-19068 , __; D CITY OF ZEPHYRHILLS • " ' S335-8TH STREET �•'� �sls��so-oo20 19�68 ' � BUILDING PERMIT SINGLE FAMILY RESIDENTIAL i PERMIT INFORMATION � LOCATION INFORMATION Permit#:19068 Issued: 11/29/2017 Address: 3186 MOULDEN HOLLOW DR Permit Type: NEW SINGLE FAMILY DWELLING � ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 225,863.25 Total Fees: 14,334.97 Subdivision: HIDDEN RIVER Amount Paid: 14,334.97 Date Paid: 11/29/2017 Parcel Number: 24-26-21-0090-00000-1060 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 WEST CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607 Phone: (813)574-5743 Lic: Phone: Work Desc: CONSTRUCT SINGLE FAMILY 2,005 SQ FT APPLICATION FEES PLUMBING FEE 129.90 SEWER CONNECTIO RESIDEN" 2,010.00 ELECTRICAL FEE 194.85 WATER.CONNECTION RESIDENI 641.00 MECHANICAL FEE 90.93 SCHOOL IMPACT FEE-sfd 1% 48.28 SCHOOL IMPACT FEE-sfr/100% 4,828.00 TRAFFIC IMPACT FEE 1% 36.32 TRAFFIC IMPACT FEE 99% 3,595.68 BUILDING FEE 963.32 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 /�,��� r "� V V � ' t�?�G����� �6 � � a Ins ections Re FOOTER 2ND ROUGH PLUMB MIS INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTO S SI NATURE PERMIT OFFI PERMIT E PIRES IN 6 MONTHS 11VITHOUT APPROVED INSPECTIO CA L FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER - . � � . � � _ � � l llllll lllll lllll llll�llll!Illll lllll lllll11111 llill llll(!II . 2017182065 - , , . ' , Rcpt:1909816 Rec: IQ3.00 " _ " , � , DS: 0.00 IT: 0.00 � 11%1612017 K, R. , ppty Clerk � PRULR S 0'NEIL,Ph.D PASCO CLERK & COMPTROL.LE 11/16/2@17 02:26 m 1 of 1 - = �. . q�_ �� ��i�� P� 1085 - Permit No. . Parcel ID Na 24-26-21-Oq60-00000-1060 NOTICE OF COMMENCENIE�iT State of Flarida Coun#y of Pasco � , THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713, Florida Statutes, the fo!lowing in4ormation is prov�ded in this Notice of Cammencement: ` 1. Description af Property- Legai H(DDEhl.RiVER PHASE ONE A PB 74 PG 101 LdT 106 _ street Address: 31$6 Mouldell Hollow Drive zephryhi(Is F� s35ao z. General Description af Improvement Single Family Residence/Pool/Screen Enclosure/Fence ' 3. Owner Information: Lennar'Homes, LLC � � - Name ' 4600 V11 Cypress St, Ste 200 Tampa _ FL. 33607 - Address City State • � (nterest in Praperty� . , Name of Fee Simple Titleholder. N�A , � {(f other than awner} , Address City State ' 4. contractor� . �ennar Flomes, LCC , . Name , ' , , 460Q W Cypress St, Ste 200 Tampa FL, 336Q7 . . , Address Gity �State � Contractor's Telephone No.. 813.574 57Q0 , 5. Surety� "' N/A ' � � Name � � , Address City State � Amount of Band: $ Telephone Na.: ' - s. ` �ender N/A � ' � Name ; � Address � , City � Sfafe � ' Lender's Telephone Na.. , � 7 Persons wiftii� the 8tate of F3orFda designated by the owner upon whom notices or other documents may be served as provided by � Section 713 13(1)(a)(7),Florida Statutes. � , � , Lennar Homes LLG _ - , , Name � _ �4600 W Cypress St, Ste 200 Tampa F�, 33607 , Address � City State ` � Telephone Number af Designated Person: 813 574 570Q 8. !n addifian to himself,fhe owner designates N�t� of to receive a copy of the Lienor's Notice as provided in Sectian 713:13(1){b),F'lorida Statutes. � Telephone Number of Person or Entity Designafed by Owner•u ' 9. Expiration date of Notice of Commeacement is one year from fhe date oi recording unless a cfifferenf dafe is specifed: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION•713,13, FLORIDA STATUTES, AND CAN F2ESUl.T IN YOUR PAY[NG TWICE FOR (MPROVEMENTS TQ YQUR PROPEFZTY. , A NOTICE OF C{}M(vi�NCENiENT MUST BE RECORDED AND PdSTED ON THE JOB S{TE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO dBTAIN FINANCING,CONSULT WITH YOUR LENDER OR,AN ATTORNEYBEFORE COMMENCING WORK OR REGORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLC}RIDA —L�-ti l � � COUNTY OF PINELLAS �-'�� 5ignature af Owner or Owner's Authorized OfficerlDirectorlParfnerlManager Vice President , r 8ignatory's Title/O�ce The foregoing instrument was acknowledged before me this 6 day of �arCh ZO�� ,by - Steve Robert Smith as Vice President {type oi a ttt4; ��.,officer,trustee,attarney in tact)for Lenii�r Homes' LLC (name of n'be�of whom instrument was ezecuted). , ". � Persona(ly Known�OR Produced identification❑ - Notary �gnature � Type of Identification-Praduced..� � ' Name(Print) E�ISS olleran � Verification pursuant'to Section 92.525,�F(orida.Statutes. Under penalties of perjury, (declare that!have read the foregaing and that the facts stated in it are t�ue to'the b'est of,my knoivledge.and belief �, - . ' � � . , r��+�' ELISSKM.,NOLLEPoqN Signature of Natural Person Signing Above .,�Cimmlaelon,�FF 88583T � , . � ��;�o,�,�, �'=���1rea June 6,2020 ` •, wpdata/bcs/bcs form; ' „f��''� MndalThruTroyFaloin+unncelOQ�3i5�7DiD � ,,._, _''c . , . _. . . . i , � . . � �' t ' ��,�����Co ��:�'�����Fi��R�DA, COUWTY OF PASCO o ��`� 1"HIS IS TO CERTIFY TMAT THE FOREGOIMG iS A � ° m�>+ TRUE AND CORRECT COPY OF THE DOCUMENT ��• , �''� � ���F'ILE OR C�F PUBLIC RECORD IN THIS OFFICE ���'� � WITN S�MY HAND AND OFFICIAL SEALTHIS � � In(�3oC�"We'1'rust o � I � ` •�, :...o�... ��i ^DAY OF "I�� .- : 2 �("") T � F�AULA S.O'iV�IL, CLERK 8�COMPTROLLER � • :.��. � • '� �c . ���7 BY '������..DEPUTY CLERK ���OF���`�� - Jacquelin� Bog�s I From: TQ Randolph (FATHOM)<support@gwfathom.zendesk.com> Sent: Wednesday, March 14, 201812:50 PM To: Jacqueline Boges - Subject: [FATHOM] Re: 3186 Moulden Hollow Dr New ##- Please type your reply above this line -## Your request (#201281) has been updated. REPLY TO THIS EMAIL or click the link below: https://qwfathom.zendesk.com/hc/requests/201281 � �___ ' TQ Randolph (FATHOM) `--�-� Mar 14, 9:50 AM MST Mi Jacqueline, Account 889145-2985959 has been established for this location and is pending mapping by our GIS team. Once mapping is complete, a service order for meter install will be generated. Thank you! ' Best Regards, TQ� FATHOM Support � Jacqueline Boges - �-� Mar 14, 6'21 AM MST Hello Forgot to mention could you rush this request more than normal. This service should have been ordered back in November and I missed it. Thank you for any help you may assist in giving to move this along expendient. f - Jacqueline Boges �...--=- 1 Mar 14, 6 1 8 AM MST New 31 86 Moulden Hollow Dr water, sewer, water meter This email is a service from FATHOM. i Jacquelin� Bog�s ', From: FATHOM <support@gwfathom.zendesk.com> '� Sent: Wednesday, March 14, 2018 9:19 AM �I To: Jacqueline Boges ' Subject: [Request received] 3186 Moulden Hollow Dr New ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. B est Regards, FATHOM Support Team TO ADD ADDITIONAL COM MENTS, reply to this email or click the link below: https://awfathom.zendesk.com/hc/requests/201281 j � � lacqueline Boges E �-- - Mar 14, G:1 8 AM MST New 31 86 Moulden Hollow Dr water, sewer, water meter This email is a service from FATHOM. , i S _ PASCO COUNTY PAS C�Y'�}[^^ DEVELppMENT SERVICES 8731 CiEizens Drive Date:2/14/2018 COUNTY FLORIDA New Part RicFiey,FL 34654 t:7r��aa�r.ac-�.�c.Li�rw;�rPLnr.:�c, 727-B47-2411 �'� 1 �@�� � i ��lV1�� �k* Receipt#: 1737960 FEE DESCRIPTION ACCOUNT CODE UNITS IM/O10E# FEE AMOUNT PAID RECEIPT# DA7E Impact Fee Residential Solid 24503100-329010 6.00 1320011 $328.44 $328.44 1737960 2/14/18 Waste Single Family TOTALS: �328.44 $3Z8.44 Receipt# Paid gv Check CC u # Cashier ID Workstation Fieceiut Date Amt Paid 3737960 Check 11890 540 BCCCP08W 02/14/2018 $328.44 Totaf Payments: $328.44 Pavor Address phone Lennar Homas 4600 W Cypress Street, 813-574-5745 Suite 200 Tampa, FL 33607 Comments: City of2ephyr�ills Permit#18979/18983/19065/19066/19067/19068, Hfdden River Phase 9A PB 74 Pg101 Lot41,105,106,107, and � Silverado Ranch Phase 2,3,4,PB 73, Pg 59, Block 03,Lot 93 and Block 04, Lot 03. Whlle you wlll ba paying your bill wlth Passo County Oevelopment Services,the full amount of the credit card ore-check fe¢s,NOTshown ebove,is cnlle�ted by Ftrst Billing pByment servitts. MyReports/reports//PRODUCTION/PASCO/ReceiptPOS V5.rpt 2/14/2018 Page 1 of 1 \ Jacqueline,Boge� From: OPC Engineering <opcengineering a"(,�")mail.wrec.net> Sent: Monday, February 26, 2018 10:14 AM To: Jacqueline Boges Subject: Re: permanent power request to be released Thank you ---- Original Message---- From: "Jacqueline Boges" <jboges@ci.zephyrhills.fl.us> Sent: 2/26l2018 9:35:49.AM To: "opcengineering@wrec.net" <apcengineering@wrec.net> Subject:permanent power rec�uest to be released Hello, � Jackie,here in the City of Zephyrhills could you please release permanent power for the address 318b Moulden hallow Dr(hidden river subdivision) single family new horne bp#19068. I need to have acknowledgment receipt af this request for the pernut file . Thank you so much and have a great day! x dackle Bo9es 8�'3-780-0020 ext�513 "A rule I have had for years is:to treat the Lord Jesus Christ as a personal friend.His is not a creed,a mere doc#rine,but it is Ne Himself we have"Dwight L.Moody Florida has a very broad publa.c records law. Electranic cammunications regarding most City of Zephyrhi.11s business are public records and available upon request. Your e-mail communi.cations may therefare 6e subject ta public disclosure. Sf you reeeived this message in error, please da not read, forward, copy, e�c. and delete immeda.ately. z Jacqueline.Boges From: OPC Engineering <opcengineering@mail.wrec.net> Sent: Tuesday, January 9, 2018 4:56 PM To: Jacqueline Boges Subject: Re: release need for tug 3186 Moulden Hollow Hello Jackie, / � . �, �°�,�`P� � Thank you for the release. Have a great day. Melissa ---- Original Message---- From: "Jacqueline Boges" <jboges@ci.zephyrhills.fl.us> Sent: 1/9/2018 4:24:47 PM To: "opcengineering@wrec.net" <opcengineering@wrec.net> Subject: release need for tug 3186 Moulden Hollow Hello my.name is Jackie I work for the City of Zephyrhills and I need a release for a Tug inspection that was done today. Could you release tug inspection for 3186 Moulden Hollow Dr(Hidden River subdivision) bp#19068. • Thank you Could you send email acknowledgement indicating you received this release. Have a great day! X dackie Boges 813-780-0020 ext 35>3 "A rule I have had for years is:to treat the Lord Jesus Christ as a personal friend. His is not a creed,a mere doctrine, but it is He Himself we have." Dwight L.Moody Florida has a very broad public records law. Electronic communications regarding most City of Zephyrhills business are public records and available upon request. Your e-mail communications may therefore be subject to public disclosure. If you received this message in error, please do not r.ead, forward, copy, etc. and delete immediately. t 1 Jacquelis�e Boges From: Jacqueline Boges Sent: Tuesday, January 9, 2018 4:25 PM To: 'opcengineering@wrec.neY Subject: release need for tug 3186 Moulden Hollow Hello my name is Jackie I work for the City of Zephyrhilis and I need a release for a Tug inspection that was done today. Could you release tug inspection for 3186 Moulden Hollow Dr(Hidden River subdivision) bp#19068. Thank you Could you send email acknowledgement indicating you received this release. Have a great day! <e d � I .�a, ' ,� � ' I � `=` _;�r� �;�:. dackie Boges - - 813-780-0020 cxt 3�13 ' "A rule I have had for years is:to treat the Lord Jesus Christ as a personal friend. His is not a creed, a mere doctrine, but it is He I� Himself we have." Dwight L. Moody ' Florida has a ver broad ublic records law. Electronic communications re ardin mo Y p g g st City of Zephyrhills business are public records and available upon request. Your e-mail communications may therefore be subject to public disclosure. If you received this message in error, please do not read, forward, copy, etc. and delete immediately. '' II � � . . ' lQ�o _- ' � ';�.,ss1�fIIHuy - '. s��� 4„�� �'�., - ,��; � �L.-'!�_�i'v'=_-�-.'ev. , :'��^^: --��t=. , - ��s�� •,` .a__ ..,,�,': ;.;,L--,-�._..�--_ ."r' City of Zephyrhills BUILDING PLAN REVIEW COIVTMENTS Contractor/Homeowner: �� � �� ;n�,�,� � Date Received: �� _ ��� `7 Site: 3 � t�� /�1�,�;1 �.� /7�ll(�?;�� i F Pernut Type: I�p �, ��—S � Approved w/no comments:❑ Approved w/the below coxnments: I� Denied w/the below comments: ❑ - �� �r�CGL� This comment sheet shall be kept with the permit and/or plans. �p� �'� Kal ' S ' —Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) i � 1 Lennar Homes-3186 Moulden Hollow Dr 2,005 sq ft o umn SQ. FEET PRICE MAIN OR LIVING: 2,005 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 225,863.25 FEE SHEET $ 866.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 963.32 ELECTRICAL: $ 194.85 ' PLUMBING: $ 129.90 MECHANICAL: $ 90.93 SUB-TOTAL $ 1,379.00 TOTAL $ 1,379.00 - SEWER: $ 2,010.00 WATER: $ 641.00 IRRIGATION: $ - TOTAL: $ 2,651.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES _ PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,057.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,334.97 � 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting '813 363 _ 2891 1 1 1 1 1 1 1 1 1 1 1 1 1 Owner's Name Lennar Homes,LLC, �� Owner Phone Number 813.574.5700 Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name N�`4 Owner Phone Number , . Fee Simple Titleholder Address N/A JOBADDRESS 3186 Moulden Hollow Drive �or# 1060 SUBDIVISION Hidden River Fhase One A pqRCELID# 24-26-21-0060-00000-1060 (OBTAINED'FROM PROPERTY TAX NOTICE) WORK PROPOSED 11./ II NEW CONSTR B ADD/ALT � 'SIGN Q � DEMOLISH � INSTALL REPAIR PROPOSED USE � " SFR Q COMM .� OTHER TYPE OF CONSTRUCTION � BLOCK Q FRAME 0 STEEL Q DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF �a00 SQ FOOTAGE 1555 HEIGHT � StOI'�/ I�BUILDING � �O �,!} VALUATION OF TOTAL CONSTRUCTION 7 �I�/ 'ELECTRICAL $ � PROGRESS ENERGY Q W.R.E.C. ' � ` AMP SERVICE �PLUMBING $ � � �� �� II�/ IMECHANICAL $ VALUATION OF MECHANICAL INSTALLATION 7� f QGAS � ROOFING Q SPECIALl'Y � OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA �YES �10 u BUILDER COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Address 4600 W. ress St.Ste.200,Tampa,FL 33607 License# CGC1518166 ELECTRICIAN ~ COMPANY Edmonson Electric, �f1C. SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Address 1034 Skipper Road, Tampa, FL 33613 �icense# EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGfVATURE REGISTERED Y/ N FEE CURRE� Y/N Address P.O. Box 5308, Bayonet, FL 34674-5308 �icense# CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc _ SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Address P•O. Box 308, Bayonet, FL 34674-5308 �icense# CAC058062 OTHER COMPANY SIGNATURE REGISI'ERED Y/ N FEE CURRE� Y/N aadress 4211 Shoal Line Blvd, Spring Hill, FL 34607 �icense# CCC057991 � i � � � � � � � � � � � � � � � � � � � � � i � i � � � � � � � � � � � � � � � � � � � i � � � � � i � � o � � � � � � � � � � � i RESIDENTIAL Attach(2)Plot Plans;.(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects - COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. . """*PROPERTY SURVEY.required for all NEW construction. . . Directions:• Fill out application completely. - Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is requlred. (A/C upgrades over$7500) *" Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers � Service Upgrades A/C Fences(PIoUSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW - ���i ...__ k ( � I . . ' . . ( NOTICE OF DEED RESTRICTIONS: The undersigned unders#ands that this permit may be subject ta;"deed" restrictions° which may be more restricfiive than Caunty regulations. `fhe undersigned assumes respansibility far campliance wi#h any applicable deed restrictions. I'' UNLICENSED CONTRACTORS AND CONTRACTOR'�RESPQNSlBlLITIES: !f the owner has hired a contractor or contractars to underEake wark, they may be required to be licensed in accordance with state and local regula#ians. If the contractor is not licensed as required by law, both the owner and contractar may be cited for a misdemeanor violation under state law. If the owner oc irttended contractor are uncertain as fo what licensing requirements may apply for the intended work, they are advised�to contact the Pasco County Building Inspection Division--Licensing 5ection at 727-847- 8009. �Furthermore, if the owner has hired a contractar or contractors,. he is advised to have the contractor(s} sign portions af the "contractor Blockn af this applicafian for which they wi(1 be responsible. lf you, as #he owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasca County. i TRANSPORTATION IMPACT/UTIL171ES IMPACl"AND RESO,URCE RECCIVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recoveryi Fees may apply ta fihe canstruction of new buildings, change ot use in existing buildings, or expansian of existing buildings, as speci�ed in Pasca County Ordinance number 89-07 and 90-07, as amended. The undersigned alsa understands, that such fees, as may be due, will be.identified at the time�of permitting. lt is furkher understood that Trarispartation lri�pact Fees and Resource Recovery Fees must be paid.prior ta receiving a "certificate of occupancy" or final power release. If the project daes nat invalve a certificate of occupancy or final power release, the fees must be paid prior to permifi issuance. F'urthermore, if Pasco County Water/�ewer lmpact fees are due,they musfi be paid priar to permit issttance tn accordance with applicabfe Fasco County.ordinances. CONSTRUCTIO.N LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the appEicartt, have been provided with ;a capy of the "Florida Construction Lien C.aw—=Homeawner's Protection Guide" prepared by the.Flarida D'epartment of Agriculture and Cansumer Affairs. If the applicant is sameone other than the"owner", ! certify..that! have obtained a copy of the above described document and promise in good faith to deliver it ta the"owner"�priar ta.commencement. � - CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with ai[ app(icable laws regulating construction, zaning and land development. Applicafiion is hereby made to abtain a permit to do wark and installation as indicated. ' I certify,that no work or installation has commenced prior to issuance af a permit and that all,uvork wil! be performed to meet'standards of all laws regulating eonstruction, County and City cQdes, zoning regulafions, and land development regulations in the jurisdiction. I a(so certify tliat I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify wliat'actions 1 must take to belin,cornpliance. Such agencies include but are nat limited to; - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands;WaterlUVastewater Trea#rnent. ! - Sauthwest Fiorida UVater Management Dis#rict-Wells, Cypress Bayheads, Wetland Areas, Aftering Watercourses. i - Arr�y Corps af Er�gineers-SeawaJls, Docks, tUavigable Waterways. - Department af Health & Rehabilitative Seiices/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - tJS Environmentai Protection Agency-Rsbestos abatement. Federal Aviatian Authority-Runways. i I understand that.the following restrictipns apply to fhe use of fill: - Use of fill is not allawed in Flood Zone"V" unless expressly permitted. , - !f the fill material .is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating voiume" wi(I be submifted at time of permitting which`is prepared by a professianai engineer . licensed by the State of Florida. � - ]f the fiEi material is ta be used in Flood Zo�e "A" in cannection with a,permitted building using stem wall constructibn, I certify that fill will be used only to fill#he area within the stem wall. - lf fill material is ta be used in any ar�a, ! !certify fihat uss of such fil! will not adversely affect adjacent properties. if use af fill is found to adverseiy�aifec# adjacent properties, the owner may be cited for vioiating the canditions of the building permit issued under the a#tached permit application,.for lots less than one (1) acre vuhich are elevated by f311,,an engineered Edrainage plan is required. ' Ifi I am the AGENT FOR THE OWNER, I pramise in good#faith to inform the awner af the permitting conditions set forth in this a�davit prior fio commencing construction. f underst�and that a separate permit may be required far electrica! wark, plumbing; signs, weils, paols, air conditioning, gas, or pther instaliations nat specifica(iy inciuded.in the application. A permi# issued shall be construed to be a license to proce�d with the wcark and not as�authority to violate, cancel, al#er, or set aside any provisions of the technical codes, nor sha3i issuance of a permit prevent the Buildirtg,flfficial from thereafter requiring a carrectian of errors in plans, cons#ructian or violations of any codes. Every permif issued shall become invalid un{ess the work authorized by such permit.is commenced vuithin six months of permit issuance, or if work authoriaed by filie permit is suspended ar abandoned for a period of six(6} manths after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period no#to exceed ninety (90) days and will demonstrate justifiiable cause for the e�ctension. [f work ceases far ninety{90)consecutive days,the jab is considered abandaned. , WARNlNG TO OWNEf�. YOUR FAl�URE TO REC�RD A NOTiCE QE COHtIMENCEMENT MAY RESULT 1N YOUR pAYING TWICE FOR 1MPROVEMENTS TO YOUR PRt)PERTY. IF YOU INTEND 70 OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY'BEFORE RECORpING.YOUR NOTICE OF COMMENCEMENT. FLORIDR JURAT(F:S.917:43} , , , � OWNER OR AGENT _ ,,,,,_,,,�_,,,,,_,,, _ CONTRACTOR � Sutascribed and swom to{ar aFftrme before me this SuEiscribed and sworn to r a �rmed}before me this _ v°-uG-c-�� py paul Sweene _ • _ �e�o��-�� by Bat Sweene - ' " ^ - Who is/are ersonall knawri to e or Who is/are ersonall nawn to me or as idet�tification. as identification. �� i . �r� Notary Public � iVotary Public , , , Commission No. FF98537 Commission No. FF98537 ' ' Elissa IvI.Holleran ' �- Elissa M.Holleran � ' Name of NotaN tvped,printed or stamped Name of Notary typed,printed or stamped _ .�..�.�. �I�I�M�.N�19��W' - ,il �I��,kli��I'AI��W . y��rsar��anE�l.���heae� �r�un"�u'tanpi��Pabaal�' 1 j ��a��r������� ��4,�1dIt�����fF�� , �, . �., e+�dwla�atT,»�P,�eivo�.�dd�11�PU , ",; . �, �drdl�ItNTkayF�a'�44+9H,�118C47�9,7tQ1 � - - i � I I _ _ __� � �, 'i � = PASCC} COUf�TY, F�t�RtDA , . .. Permtt No. d ��g Date Permi�ted ,� --/____7-1.?�^ Builder NametOwner Name �VtLzh'�'�Yne �.[.-� Cantroi# Gounty Parcei No. ' -'�-2-�-UDqO �-�O�Z� SubDiv: �Sp((,{'p���2y-� Address/Lacation ��,,,_8 (o l�.n{�(,,�CitP� �t�a�c�� __ ClassiflcatfoM"ype of Usa �i�tP �"�''''t��-f__ TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Z�OC�J Exempt []Yes [] Na Ho�nr Determined � lmpact Fee Amount $. v�- ��232• Zone No. TAZ: SCHt10L IlU1PAGT FEE Account (056) Singfe-Family Detached Nouse Amount $ �1��lo• 2�3 (057) Mobtle Nome (058) Other Residential 123) Gollectlan Fee Exempt []Yes ❑No How Determ(ned PARKS AND RECREATit3N FEE Land Account Land Credit Land Totat Recreation Account Recreatian Credlt �Recreatton Tota! Zone TOTAL AMOUNT $ Z(�`���� Exempt (�Yes ❑ Na Haw Determined LIBRARY FEE �and Accaunt Land Credit Land Totat Facillty Accoun# Faciitty Cred(t Faciitty Total Exempt ❑Yes ❑ No How Determ{ned Tota(Amou���=- RESOURCE FEE ERU TOTAL AMOUNT � Praparad By ' Checked By NO CERTtFiCATE OF OCCUFANCY WILL BE ISSUED OR FIMAL 1NSPECTION PERFQRMED UNTIL THE TOTAL AMOUNTS LISTED HAVE SEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING lJFFICE OF PASCO COUN'TY Acknowladgement befow doas not impiy acceptance of concurrence,but sfmpty racelpt of a aapy of thfs form,piacing , the buliding parmit ownar on notice of this assessment and thQ condittons ot paymant ior same. DATE RECEIVED BY RECEfPT NO. DATE BY ; . � I i Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to coinply with R401.3 of the F.B.C. 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. ' 4. Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. , 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. 9. No electric,plumbing,mechanical, or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. A112008 N.E.C. Codes will be enforced. 23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. 25 A COpy of the ener,gv cacls shall be with perntit at all tinies 26. Cony of fnal insulation report shall be provided with ne�•n:it befoYe�na� � F.F.E.-Finished Floor Elevation F.B.C-Florida Building Code 5�'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008) : • _ E �.� ' � I V� � 4� ,�''� � � � 1 . . � � ,.��.....,......y...._....�_, '� ' ,�� F� ' � .,... ..�.. _ ....:;..� • 1, � ' �, ' .,,..._,.......,.._.r.. _,�.....�.. � .:._....,, ...:_ .�...�.� _•� ,I r ...w. ;r��� , . � � : .�_ ; ` '��,,, ` � . :, � ' , �.��,� -�..._ II - , �,� r,��'. �� `t ,�? _ ' '�FF�. � �. " � ,:= ���� . � �1 ��.. �: , ��: '� .�Q� r ;► I • ,�-� �� - � � -� �� ` �� rs.�f t �'� . ,�,,�� � �� . v -�' �� � '� } L i� ,� .� ``�,� � � �,�-_�. �'%•'' ��� � �1 � .�� �� ��:.. t � . F ' � "`.,� "�•...�►�� l �.. . , . �. �"' , � �� 7�.s� '� ! -�� � , � �e:��► � � �► , - `� ti� � � ''�`� ~7 ; �� � � '� ,,;�• , � �� ,� �� . 1 ,�� � � :'�� � .� � r, � . �. �-� , .. :�:-- �.�; � � f� ��.. +� � . 1 � ���.i.. i� ��.. A. � �,�; � . � � � F- j -. l�� �° �'��1 �' -� , ., +� �a. i `�,, �ti r� f"��`•..� �. � � �� � � A� . - - E� 1 -�,�o �.;� '�, � � , ! � � �� , �,. FP E!. �.�� p �: ,� �A'�r ' �,� �.� `�` '' . .''' i �.. �.� �ti r �� �, ��= � .. ,� ` ,;.� • ' � ,� � ;i n ,,. • E �� , ' � � . ~� � � '� '�$ ' �.�,,, � .�� �.�s .' �'��1 '��� t�` . ` � '���� �'"` ' �.' -��..� „ . � � - �r� .r � +.. . ,: �`• , ,= � ' � ' �: •--�,r�,� ` �a 1, � 1 .1 _ � � �,�, �.. � '�.,� �� FF�1. ' �� � 73:�0 1 -'���� 1' ;� .�'`�:,r.r"ic � , ti: � � r '' '�'� .ti 1 � '� '� i ��`'� � �y� ! �$. � � A O 1 � �� ..�"'r/' �FF.txl. l� `� *�. i A � ' 7SA� ' � � �� � ' 1 �'�� .+1 '�^ ��+'�.5/ �t� �� F��. �`' .�...�. - I �1 '� � _ � �11 ,.� �'' '� t � i• rz;� � ..,._� � �� �� �� 1� ��,;,,.r �. . 1 ` • ��� 1 �1 i " i■�s �r,sN r,, ,1�q�1 �,�.� , .�� �' .. � ' ' �; �x'i�,r`��+ �� �' �l��e�rn .� 1 � ��ti', . f 1� � � t�. . � PI�OT PLAN NOT A BOUNDARYLSURVEY �EC" 24 , TWP. �� S, RNG.'2� E. �OT 106 ' aEnr�Nc ens�s: HIDDEN RIVER PHASE ONE A NORTF# BOUNOARY OF SUBJECT PLA7 �tG S 85'40'�a` E PASCO COUNIY, FLORlDA_ �T '(};�g $�}RttEY 15 StT$SECZ TQ ANY FAC75 MAT �� NAY 8E D15CCd5EU BY A FUIt ANp ACCURA7E 71TLE SEARCH. ALSO SUBJECT TO SETBACKS. PRE�lMtldARY DRAWlNG: Eas�ENTs nwn RES'rn�cnoius o� REcoRn. 7HIS AtAN SS FOR PERhi1iSINCi PURPOSES o UY4Y, N07 F4R CONSTRUCTICNV. �IERIFY h UNOERGRWNp FQOTER, SfE�.t WAtt, AttD ALL CIIMEN51C1N5 BfFQRE ANY CONSTRUCTION. � uNpEttc,�WND ununEs artE No7 �pCaTED C�t � SHOWN_ LEGENLl: ^ 00 NOT SCALE 11i�5 PRINT. O1ktEN51CMi5 ANO �+ = PROPOSfO DRAINAGE FLOW � NOTES TAKE PREFERENCE_ {Op.00}- = PROPOSEO GRAOE N E-00.00 = EwSnNG GRAOE cEftraN UATA sKOwH KEr�Eoaz BaSEo o� ENpNEERING PLANS PROVi0E0 BY CUENT. STF?t.lC71lRE TIES SHQwN HEftEOi� DENOTES ldEASURENEAtT FROit F�2Y BOARUS%f0t3NDA'iCQN TO PROPERTY UNE. � = 10' ORAiPNGE/UitUTY E1lSEtAEM / ... = 70' DRNNAGE EASE6IENT � �+� 7 1� LOT t05 � � i,�9 t/ ��"f oo-=-_- / �--� S , "i�V�►'C`��c�, �` �g-a�.. :;� � lSpg�. � V �`� _ �` � - M/, � ,04::: �7p�Q,. �� � M '_1`.- J . O -.�� - -�•--` .tih. / 1-� h=. �'� � / * ��� h r•+:.' � '/ \ v ��d„>. LOT 106 � '�o. j�. �¢ �, " `Ql S te„'�'r„�-9` h�,y�'0v QCP �D,.�,4. � c. 3°9 ' •�A� c� �' -'- . :. � p.� +�."QT ."A 2 � � \ `Sq� � 4r o-0o c as � �. O� -, a�,� ."G�, �ss}4r �' � oo_o, � s3. �• � � G _ S'�t� s�\ .�,� ��. f# ' 1 OW LOT AREA CALGULA'iIONS 4Q'� \ � � LOT a 8195.26 Sq. F'f. �y \ �''. ''•:Tv � UVING AREA 1556 SO. FT. ry� '`�s' LOT 329 fNiRY � 40 St). FT_ �j� - �� - GARAGE = 406 50. FT_ COVEt2E0 LANA1 N/A SU. FT_ LOT 10� �O• \. PA3t0 � 23 5Q. � � \ CQNC. ORIVE = 4� SO. F'T , \ A/C �6c CO��C PAD = 9 SQ. FT PRIYATE SiDEWAIK = 28 SO. fT_ � JiAPERVtOUS - 31 z ^ � '2526 SQ. �. o SOp - 5669 50. FT y, OFF LOT AREA CAL.CULATIOIdS � - RIqiT QF 1YAY - 599.�4 $p. �_ � \ � QRt1l� APAON = t� SQ. F7_ ," PUB!!G 9DEWAl.Ic = ZO& SQ. FT_ _5pp � 249 So. FT, LOT 330 TCtTALS N��� aRea = s�sa.so so. Fr. �ar atnaNc �E = n ORIYEWAY = 608 Sq,.�. PROPOSED PAQ ELEVATION = N/A 90EWALK � 23a SQ. f7. fRONT SETBACK = 20' Spp = 5918 S0. FT. 3DE SETBACK = Sd• REM SETBApf = t0' CURVE DATA cu�r i aao2vs a.ac cHa�o a�+�c a�.Tn pROPQSED- cs> >30.00' sz.ss' s2.00• r+ 3o-n•ot` � zsoa•ze' LOWEST FLOOR ELEI/ATIONS: csz � �3a.00' s�.�x' s�.3s• N 53't3'09'E zrax3e- CtQ1 I 240.00� 96.65' 96.q0' S 34'17'O)"l+t 2SOC'25" �.(�N(a /�1R�1: 7�_$r'J� GARAGE AREA: DESCRIPTIl7N: ELEVA710NS REFERENCED TO �Qi` ]06. MAP OR PLAT EN31TlEQ "H@DEN RNER PNASE ONE A", NATIONAL GEOOEf1C VERTlCAL AS RECORDED tN PLAT 800K 074, PAGES t01 THROUGH 12i, DATUM 4� `1929. MEAN SEA OF THE PUBLIC RECORDS OF PASCO COUNTY,. FLORIDA. LEVEC= 00.00 Ff. APPARENT FL000 HAZARD ZONE: "X" COMMUNITIf PANEL NO. 120230 046Q D EFFECTIVE DATE: 9/30/1992 Froyeci Atumber. _ Squore Feet= $19536 ± ' lEMNXR HOMES C'cG�NO: • [C)= CALCULA?ED DATA, (D)= DEED pATA,�(M)= MEASURED DATA, (P)= PLAT DATA, g= CEN7ERLINE. A/C= AIR COWO171pNER, B/C= BACK OF CURB. G/S= CO.tG4c7E SLA9. Gv= GH4:2D. t�-t8= CH{3.40 BEARtNG. CIF= GHAiFt UNK FENCE C4t+tC= C4NCR£3E. COY.= COLEREQ.-Ef,k?d=£OG£ 4� PAVE�+tEt17. ESµ'T= EASEI�IEHT, FjC= FEyCc CO�v.R, �CM= FOUt�6 CO�SCRETE t�tONUMEtVT, FlP= FOUND tF20N PiPE. FlR= POUNp tRQN RO�,�FJiBct?= r-OUN�`J'bSAR dc DISK, FPP= FWND PlNdiED PIPE. I.FE= LOY4E57 FLOOe2 ELEVATIOV, MAS.= MASONRY, OR= OFFlpAl. RECORO BOOK, P�� PLAT BOOK,.�Pp'=F'EiklS'M'.G`N�CC:TJTROL POINT, PRM= PERYANENT r` `'_ REFERENCE MO.\UMEN7, R/W= F21G'iT OF wAY, R= RAD1U5. SIR=5E7 7/2' IRON ROD dc CAP No. 4493. SN&D=�w-� NAIk-�=DISK,��E'!liE= TE1dPQRARY BENCHIIARK, t3 = Ui1Cl7Y FOLE_ W = tTtOdO FENCE. R = RADIAE. �=�r=�i,�� JOHPI R.BEACH 8c ASSfJC1ATE5,INC. Orawn By: ry� �.� ,��-4- -� " � _r- JMYS tih /"'\^ � a ''� � + T StiR�YORS AND MAS'PERS Checked Sy- 9ii YIcST ST_ PEiER56URG DRiVE -;"` _ ONE OIDSMAR, fl.ORIOA 3t677 3� ` � - "r�;} :i"'� ; wAY (g13) 85a—t276 FAx (813) 855-8370 `-'CO1e: �,_30, :j -_ ~ " ' n^- 'S, * HOi VAUD K't3H0UT THE StGNATURE AND paie- PLOT PUW 9/OS/20i7 GH ��� �" �-n � � �1 1� �dl iHc 0:21GINA1. RAISED SEAL Oi A FLORIDA JO . BFACH"� r`�"_ "-'��^ .,� UCtNS:D SUR�YOr2 AND MAPPER RIDA Gr I.AND'S!JRV�YG`R ��2984 !.B 4493 Rerisioas REYISED PtR DESCRiPStt}N 3/t3f T7 JBS , --_ . - T' y„ � � . . FORM R405-2014 FLORIDA ENERGY EFFICIENGY CODE FCIR BUILDING CONSTRUCTION Florida Department af Business and Professional F2egulation - Residential PerFormance Method Project Name: 1551 B sf ADS Builder Name: Lennar Homes street: 3186 Mouldean Hallow Drive Permit Office: �1 of Zephyrhills Gity,S#ate,Z'sp: ,FL, Permit Num6er ��j(,�(�?�j Owner. Lennar Homes Jurisdiction: 611600 pesign Location: Fl.,Tampa County Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1492.0 sqft.) Insulation Area 2. S9ngte famity ar mu(tip3e family Single-family a.Cancrete Block-Int lnsul,E�cterior R=4.1 9 976A0 ft2 b.Frame-Wood,Adjacent R=11.0 316.00 ft 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Namber of Bedraoms 3 d•NIA R= �z 5. Is this a worst case? Yes 10.Ceiling Types (1555.0 sqft.) Insulation Area Z a.Under Attic(Vented) R=30.0 1555.00 ft 6. Ganditioned floor area abave grade(ft�} 1555 b.NtA R= ft2 Conditioned floor area below grade(ft�) 0 c.N/A R= ft22 11.Ducts R 1� 7 Windows(1d4.3 sqft.} Description Area a.Sup:Attic,Ret:Main,AH:Main 6 312 a. U-Factor Dbl, U=0.54 55.00 ftz SHGG: SHGG=0.31 b. U-Factor. Dbl,U=0.56 33.33 ft2 �2•Cao(ing systems kBtuthr Efficiency SHGC: SHGC=0.32 a.Central Unit 25.2 SEER:16A0 c. U-Factor� Dbl,U=0.56 16.0�ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor N!A ft2 a.Electric Heat Pump 21.8 HSPF:8.50 SNGC: Area Weighted Average Overhang Depth: 1.319 ft. Area Weighted Average SHGC: 0.309 14.Hot water systems a.Elecfric Cap:40 gallons S. FloorTypes (1555.0 sqft.) Insulation Area EF•0.950 a.Siab-On-Grade Edge Insulation R=4.Q 1555.fl0 ftz b. Conservation features b.N!A R= �2 None c.N/A R= �� 15.Credits Pstat Glass/Floor Area: 0.067 Total Proposed Modified Laads: 50.84 �w�� TQta!Saseline Loads: 50.87 /"\ 1 hereby certify that fhe p[ans and spec[fcations covered by Review of the plans and ��'fi�.��'r��.� .- this calculation are in compliance with the Florida Energy specifications cavered by this �;;�r ,�. '-_•;;y O c_ �, � ' Gode. calculation indicates compliance . �'Q'+sr�,, ' `==����.�`�.Ys+ with the Flarida Energy Code. •I••� rn,���`r%:=y=�:�',•;�`ti,�� PREPARED BY: �7(a'VPT{��I�IC� Before construction is completed c�'� � �`�' "" DATE. this building will be inspected foc � '"�1`���C��-- � compliance with Secfion 553.908 ' *., �"� = : �., I hereb certi that this buildin as desi ned,is in com liance Flarida Statutes. � Y fY 9, 9 P �?'�,� '._-:. ;,�c�� .' with the Flarida Energy Code. � aLi'WE`C�' : C?WNERlAGENT: � BUILDING FFICIAL: DATE: � _ DATE: - Campliance requ9res cerEificatian by the air handler anit manufacturer that the air handler enclosure quaEifies as certified factory-sealed in accordance with R403.2.2.1. ` -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4,4.1 and an envelope leakage test repart in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to autdoors, tested in accordance with Section 803 af RESNET Standards,is not greater than 0.080 Qn for whate house. 9/13/2017 12:05 PM EnergyGaugeO USA-F'IaRes2014 Sectian R405.4.1 Compliant Software Page 1 of 4 � . . . . FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential PerFormance Method Project Name: 1551 B sf ADS Builder Name: Lennar Homes street: 3186 Moulden Hollow Drive Permit office: City of Zephyrhills City,State,Zip: ,FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611600 Design Location: �FL,Tampa County:. Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1492.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ftz b.Frame-Wood,Adjacent R=11.0 316.00 ftZ 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ftZ 5. Is this a worst case? Yes 10.Ceiling Types (1555.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1555.00 ft' 6. Conditioned floor area above grade(ftz) 1555 b.N/A R= ftZ Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ftZ 7 Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311 I a. U-Factor Dbl,U=0.54 55.00 ftZ SHGC: SHGC=0.31 b. U-Factor Dbl,U=0.56 33.33 ftz 12-Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 25.2 SEER:16.00 c. U-Factor: Dbl,U=0.56 16.00 ftz SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a.Electric Heat Pump 21.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.319 ft. Area Weighted Average SHGC: 0.309 14.Hot water systems a.Electric Cap:40 gallons 8. FloorTypes (1555.0 sqft.) Insulation Area EF 0.950 a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ftZ b. Conservation features b.N/A R= ftZ None z c. A R= ft 15.Credits Pstat � Glass/Floor Area: 0.067 Total Proposed Modified Loads: 50.84 p A C C I Total Baseline Loads: 50.87 r/`'1�7�7 I hereby certify that the plans and specifications covered by Review of the plans and Tk�.E;S� . this calculation are in compliance with the Florida Energy ' specifications covered by this -���� _ �rQO , Code. calculation indicates compliance '��±�,,,�''� `'-���;��K+ . �" with the Florida Energy Code. �+ �irrr`,�%�.�;:::�.,;.�i�`•`ti,'r0 , PREPARED BY: �2G�'1/� f��j'I�YC Before construction is completed ' ''y �"°`-"'" ��� DATE. this buildin will be ins ected for ~ 9 P C7 �`_1�'�j �: ;� . compliance with Section 553.908 ' * -�~'� ' :_ _� I hereby certify that this building,as designed, is in compliance Florida Statutes. .� , , �,� with the Florida Energy Code. G'Otj yyj,;:�� _ OWNER/AGENT: BUILDINC�OFFICIAL: DATE. DATE: �l��L��� - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.080 Qn for whole house. 9/13/2017 12:05 PM EnergyGaugeOO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 i , , , . • • . FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1551 B sf ADS Builder Name: Lennar Homes street: 3186 Moulden Hollow Drive Permit office: City of Zephyrhills City,State,Zip: ,FL, Permit Number� Owner. Lennar Homes Jurisdiction: 611600 - Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1492.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ftz b.Frame-Wood,Adjacent R=11.0 316.00 ft2 3. Number of units,if multiple family 1 c.N/A R= �_ 4. Number of Bedrooms 3 d.N/A R= �: 5. Is this a worst case? Yes 10.Ceiling Types (1555.0 sqft.) Insulation Area 2 a.Under Attic(Vented) R=30.0 1555.00 ft 6. Conditioned floor area above grade(ft� 1555 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ 11.Ducts R ftZ 7. Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311 a. U-Factor� Dbl,U=0.54 55.00 ft2 SHGC: SHGC=0.31 b. U-Factor Dbl,U=0.56 33.33 ftZ 12•Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 25.2 SEER:16.00 c. U-Factor Dbl,U=0.56 16.00 ftZ SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a.Electric Heat Pump 21.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.319 ft. Area Weighted Average SHGC: 0.309 14.Hot water systems a.Electric Cap:40 gallons 8. Floor Types (1555.0 sqft.) Insulation Area EF 0.950 a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ftZ b. Conservation features b.N/A R= ftZ None c.N/A R= �Z 15.Credits Pstat Glass/Floor Area: 0.067 Total Proposed Modified Loads: 50.84 pASS � Total Baseline Loads: 50.87 I hereby certify that the plans and specifications covered by Review of the plans and :a�'S�:S�':q�,� --._ this calculation are in compliance with the Florida Energy specifications covered by this ��S' ,, ' __-�_� O . Code. calculation indicates compliance ���i;,T;'�, `_ '�:``:�.�e+ �" with the Florida Ener Code. �+ iir,i, `�, •,;:::�:•;:+.�` � ` PREPARED BY: �7G�VG f���'(GYG 9Y � ' ;:�;-w;'` 51 p Before construction is completed ` � DATE: this buildin will be ins ected for � �`��' , ~ ',i` O 9 P t� � -��ll� �. ; compliance with Section 553.908 �:, : .-,�. . I I hereby certify that this building,as designed, is in compliance Florida Statutes. -�C ` ��.t I with the Florida Energy Code. �D'y�i�'C¢ , OWNER/AGENT: BUILDIN OFFICIAL: DATE. DATE: �- � - - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.080 Qn for whole house. 9/13/2017 12:05 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 � . . . FORM R405-2014 PROJECT Title: 1551 B sf ADS Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1555 Lot# Owner. Lennar Homes Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County Pasco Jurisdiction: Whole House Fan: City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: 2017 CLIMATE � IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium " BLOCKS Number Name Area Volume 1 Blockl 1555 12440 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 Main 1555 12440 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 134 ft 0 1555 ftz �_ 0.3 0 0.7 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch �� # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1684 ftZ 0 ftZ Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC � 1 Full attic Vented 300 1555 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 UnderAttic(Vented) Main 30 Blown 1555 ftZ 0.11 Wood , 9/13/2017 12:05 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 I � ` . , . FORM R405-2014 . WALLS Adjacent Spa� Cavity Width Height Sheathing Framing Solar Below 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 20 S 160.0 ftZ 0 0.600000 0 2 E=>SE Exterior Concrete Block-Int Insui Main 4.0999 54 8 432.0 ftZ 0 0.600000 0 3 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ftZ 0 0.600000 0 4 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 33 8 264.0 ft2 0 0.600000 0 _ 5 N=>NE Garage Frame-Wood Main 11 19 8 152.0 ft2 0 0.01 0 _6 W=>NW Garage Frame-Wood Main 11 20 6 8 164.0 ftZ 0 0.01 0 7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 � 8 48.0 ftZ 0 0.600000 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ftZ WINDOWS Orientation shown is the entered orientation => chan ed to Worst Case. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 16.0 ftZ 1 ft 0 in 4 ft 0 in Drapes/blinds None 2 E=>SE 2 Metal Low-E Double Yes 0.54 0.31 16.0 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds None I 3 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 16.0 ftZ 1 ft 0 in 1 ft 0 in Drapes/blinds None 4 S=>SW 7 Metal Low-E Double Yes 0.56 0.32 33.3 ftZ 2 ft 0 in 0 ft 6 in Drapes/blinds None 5 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 23.0 ftZ 1 ft 0 in 1 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 408 ft2 408 ftz 40 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 ' 1036.7 56.91 107.03 .1906 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.5 21.8 kBtu/hr 1 sys#1 9/13/2017 12:05 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 ( 1 � � � • + . FORM R405-2014 COOLING SYSTEM # System Type � Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 25.2 kBtu/hr 756 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM I FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / —Supply— —Return— Air CFM 25 CFM25 HVAC# �� # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 311 ftZ Main 77.8 ftZ Proposed Qn Main —cfm 124.4 cfm 0.08 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb Mar A r Ma X Jun Jul Au Se Oct Nov Dec Heating �Jan �Feb f X Mar �Apr f �May Jun Jul Au9 Sep Oct Nov Dec Ventin Jan Feb [X Mar A r [ Ma Jun Jul Au Se Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 9/13/2017 12:05 PM EnergyGaugeOO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 4 of 4 � , . ' ' . FORM R405-2014 . ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index,the more efficient the home. „ FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ft2 b.Frame-Wood,Adjacent R=11.0 316.00 ft 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number af Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area Z a.Under Attic(Vented) R=30.0 1555.00 ft 6. Conditioned floor area(ft2) 1555 b.N/A R= ft� 7. Windows'* Description Area c.N/A R= ft� a. U-Factor: Dbl,U=0.54 55.00 ftz 11.Ducts R ftz a.Sup:Attic,Ret:Main,AH:Main 6 311 SHGC: SHGC=0.31 b. U-Factor Dbl,U=0.56 33.33 ftZ SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.56 ' 16.00 ft2 a.Central Unit 25.2 SEER:16.00 SHGC: SHGC=0.28 d. U-Factor N/A �2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 21.8 HSPF:8.50 Area Weighted Average Overhang Depth: 1.319 ft. Area Weighted Average SHGC: 0.309 8. Floor Types Insulation Area 14.Hot water systems z a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ft EF:0.95 b.N/A R= ftz c.N/A R= {�z b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building �- ;��,��.-� - Construction through the above energy saving features which will be installed (or exceeded) �,�.a� "" `�?2?0, -. in this home�before final inspection. Otherwise, a new EPL Display Card will be completed y4�",,;;`'� ���;.� ''�,;�.. - based on installed Code compli t features. � ?ri„�r�%;:"_.'"� '��°s��o_ ;:;_-.'%„v,. :x� �. �.�•,��.. _ ;, t� Builder Signature. _, Date: 09/14/17 �. :���(�'`_� � , .*. � � Address of New Home: Ci /FL Zi '�' 3186 Moulden Hollow Drive tY p�Zephyrhills,FL 33540� ;�G������� :- '`Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/13/2017 12:09 PM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Buildin Anal S�S Job: 1551BsfADS g y Date: 9/1312017 Entire House By: Dave � BAYONET PLUMBING COOLING HEATING ' • - • � For: Lennar Homes � - • • • � Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ftZ Btuh % of load Walls 5.6 6022 27.8 �� GleZlllg 30.2 3178 14.7 wa�� nt��o-ation Doors 23.5 480 2.2 Ceilings 1.3 1950 9.0 Floors 3.7 5815 26.8 Infiltration 1.9 2323 10.7 D ucts 1901 8.8 Fioo� I� Humldification 0 0 Glazing Ventilation 0 0 DooCeilings Adjustments 0 Total 21670 100.0 • • Component Btuh/ft2 Btuh % of load ' Walls 2.8 2996 15.6 Walls Glazing 59.1 6224 32.4 Intemal Gains Doors 18.4 376 2.0 Ceilings 1.7 2697 14.0 Floors 0 0 0 Infiltration 0.4 520 2.7 i • � Ducts 2200 11.4 - Ducts Ventilation 0 0 � Internal gains 4210 21.9 ��azin9 BlOwer 0 0 Infiltration Adjustments 0 Ceilings Total 19223 100.0 Other ', Latent Cooling Load= 2870 Btuh Overall U-value= 0.103 Btuh/ft2-°F Data entries checked. �. -�- wrightsoft� 2017-Sep-13 12:11:07 �� Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 ...with CBA27UHE AH's\155181 sf ADS drawn 2ton.rup Calc=MJ8 Front Door faces:NW ,, ; . ' ' . . Pro ect Summar�� Job: 1551B sf ADS 1 '1 Date: 911312017 Entire House By: Dave BAYONET PLUMBING COOLING HEATING ' � - • � For� Lennar Homes N otes: � - � • • , Weather: Tampa International AP, FL, US \ Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 39 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 55 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 19769 Btuh Structure 17023 Btuh Ducts 1901 Btuh Ducts 2200 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 21670 Btuh Use rrianufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 19223 Btuh Method simplitied Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2479 Btuh Ducts 391 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1555 1555 Equipment latent load 2870 Btuh Volume(ft') 12438 12438 , Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 22092 Btuh Equiv.AVF(cfm) 54 29 Req. total capacity at 0.85 SHR 1.9 ton '� Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-024230-21 Cond 14HPX-024-230-21 AHRI ref 10258598 Coil CBA27UHE-024-230*++TDR AHRI ref 10258598 Efficiency 8.5 HSPF Efficiency 13.5 EER, 16 SEER Heating input Sensible cooling 21420 Btuh Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh Temperature rise 25 °F Total cooling 25200 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.87 Capacity balance point= 32°F Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. C. "� wrightsoft� 2017-Sep-1312:11:07 �� Right-Suite�Universal 2017 17.0.23 RSU05714 page 1 .with CBA27UHE AH's\1551B1 sf ADS drawn 2ton.rup Calc=MJ8 Front Door faces:NW . . � � F < � , . Manual S Com liance Re ort Job: 1551B sf ADS p p Date: 9/13/2017 Entire House By: Dave BAYONET PLUMBING COOLING HEATING ' • - • � For: Lennar Homes • • • • � Design Conditions Outdoor design DB. 91.3°F Sensible gain: 19223 Btuh Entering coil DB 75.7°F Outdoor design WB: 77.3°F Latent gain: 2870 Btuh Entering coil WB 62.8°F Indoor design DB: 75.0°F Total gain: 22092 Btuh Indoor RH. 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Lennox Model: 14HPX-024230-21+CBA27UHE-024-230*++TDR Actual airflow: 800 cfm Sensible capacity: 21420 Btuh 111% of load Latent capacity: 3780 Btuh 132% of load Total capacity: 25200 Btuh 114% of load SHR: 85% � • � Design Conditions Outdoor design DB: 30.8°F Heat loss. 21670 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer Lennox Model: 14HPX-024-230-21+CBA27UHE-024-230"++TDR Actual airflow: 800 cfm Output capacity: 21800 Btuh 101% of load Capacity balance: 32 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer• n/a Model: n/a+n/a Actual airflow: 800 cfm Output capacity� 0 kW 0% of load Temp. rise: 0 °F Meets are all requirements of ACCA Manual S. ... wri htsoft� 2017-Sep-1312:11:07 �, 9 Right-Suite�l Universal 2017 17.0.23 RSU05714 Page 1 � ...with CBA27UHE AH's\1551B1 sfADS drawn 2ton.rup Calc=MJ8 Front Doorfaces:NW 5335 - 8TH STREET , . (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 3186 MOULDEN HOLLOW DR Owner: LENNAR HOMES LLC ZEPHYRHILLS, FL. 4600 WEST CYPRESS ST STE 200 Subdiv: HIDDEN RIVER TAMPA, FL. 33607 Parcel: 24-26-21-0090-00000-1060 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers , Use Classification: NOT APPLICABLE Permit Number: 19068 Date: 3/ /2018 i �� ISSUED BY: BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE -- � �` -` Jacqueline Boges To: City of Zephyrhills Support Subject: RE: Request#201281: How would you rate the support you received? From:City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent:Saturday, March 24, 20181:03 PM To:Jacqueline Boges<jboges@ci.zephyrhills.fl.us> Subject: Request#201281: How would you rate the support you received? ##- Please type your reply above this line -## Hello Jacqueline Boges, We'd love to hear what you think of our customer service. Please take a moment to answer one simple question by clicking either link below: How would you rate the support you received? Good. I'm satisfied Bad, I'm unsatisfied Here's a reminder of what your ticket was about: ... �7 f� .� �_� � �1� r TQ Randolph (City of Zephyrhills Support ) � ------j Mar 23, 9.01 AM MST Mapping Complete. 889145-2985959, SO #655025 Best Regards, TQ� FATHOM Support � "� ` TQ Randolph (City of Zephyrhills Support ) p( � � ` �L Mar 1�, 9 50 AM MST Hi Jacqueline, Account 889145-2985959 has been established for this location and is pending mapping by 1