HomeMy WebLinkAbout17-18903 .
CITY OF ZEPHYRHILLS
, � , � 5335-8TH STREET
. � (sispso-oo20 18903
BUILDING PERMIT SINGLE FAMILY RESIDENTYAL
PERMIT INFORMATION ' � LOCATION INFORMATION�
Permit#:18903 Issued: 10/06/2017 Address: 37851 PRAIRIE ROSE LP
Permit Type: GENERAL BUILDING PERMIT ZEPHYRHILLS, FL.
Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 210,880.80 Total Fees: 9,507.89 Subdivision: WALNUT GROVE TOWNHOMES
Amount Paid: 9,507.89 Date Paid: 10/06/2017 Parcel Number: 15-26-21-0210-00000-0240
CONTRACTOR INFORMATIOIV OWNER INFORMATION
Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD MOBILE HOME SVC INC
Addr: 4209 GALL BLVD Address: 38930 BUTTERFIELD LN
ZEPHYRHILLS, FL. 33542 ZEPHYRHILLS FL 33542
Phone: (813)377-7395 Lic: Phone: 813-973-5250
Work Desc: CONSTRUCT TOWNHOME 1,872 SQ FT
, APPLICATION FEES
BUILDING FEE 917.41 ELECTRICAL FEE 184.73 PLUMBING FEE 123.15
MECHANICAL FEE 86.21 SEWER CONNECTION RESIDEN" 2,010.00 WATER CONNECTION RESIDENI 641.00
WATER METER RES 3/4" 473.78 FIRE PLAN REVIEW FEES 104.20 FIRE INSPECTION FEES 12.50
POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35
PARK FEES TOWNHOMES 769.56 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
�s� S�-��=�/ 3_a r- ��� � �
�
� 5���
�20 ,Y��
Ins ections Re uired
FOOTER 2ND ROUGH PLUMB MIS INSULATION CEILING I
FOOTER BOND DUCTS INSULATED SEWER MISC. �
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications and Must Accompany Application. All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
� l�'
CONTRACTORS SI NATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT I�PPROVED INSPECTIA
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
I
. ' �
- � Pasco couNnr '
�
��� BUILDING CONSTRUCTION SERVICES
' 8731 Citizens Drive Date: 12/29/2017 '
Suite 230
�ti New Port Richey, FL 34654
� 727-847-8127
** NQT A PERMIT **
Receipt#: 1728034
FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE
impact Fee Residential Solid 24503100-329010 1.00 1309091 $0.39 $0.39 1728034 12/29/17
Waste Cando,Multi-Family MH
in Park,per Unit
TOTALS: 50.39 50.39
Receipt# Paid Bv Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid
1728034 Check 2238 2238 534 BCCCPI5W 12/29/2017 $0.39
Total Payments: 50.39
Pavor Address Phone
BAI LEY 18903
ZHLLS
37851 PRAIRIE LP
Comments•
f � �U �
MyReports/reports//PRODUCTION/PASCO/ReceiptPOS V4.rp1 12/29/2017 Page 1 of 1
Single Family Dwelling �
Plan Review Comments
1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan.
2. Lots shall be graded to comply with R401.3 of the F.B.C.
3. Compaction test required if 24" or more of fill dirt is brought in at any one place. •
4. Tie in survey required before pouring concrete.
5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have
expansion material.
6. All setbacks shall be met.
7. All property markers shall be uncovered and marked at time of first inspection.
8. All A.D.A. requirements shall be met.
9. No electric, pluinbing, mechanical, or framing shall be covered without an inspection and
approval first.
10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).
11. Appliances shall not be installed in a location where subject to mechanical damage unless
protected by approved barriers. M303.4 of the F.B.0
12. Water heaters shall comply with section P607.3 of the F.B.C.
13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1
14. Return air in all bedrooms. F.B.C. M1620.4
15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C.
16. All glazing requirements are to be in accordance with R308.4 of the F.B.C.
17. All means of egress are to be in accordance with R311 of the F.B.C.
18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C.
19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker.
20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating
or appliances or an attached garage. They shall be installed in accordance with the F.B.C.
21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all
underground plumbing and electric.
22. A112008 N.E.C. Codes will be enforced.
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0
22. In accordance with the Land Developinent Code, lots shall be sodded before final at least 10
feet around the structure.
F.F.E.-Finished Floor Elevation
F.B.C- Florida Building Code 5�'Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008)
15-26-21-0210-00000-0240 � Pasco County Property Appraiser Page 1 of 1
Data Current as Of: Weekly Archive- Saturday, September 30, 2017
Parcel ID 15-26-21-0210-00000-0240 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
BUTTERFIELD MOBILE HOME Ag Land $0
SERVICE INC Land $4,373
38930 BUTTERFIELD LN Building $0
ZEPHYRHILLS FL 33542-1677 Extra Features $0
Physical Address
37851 PRAIRIE ROSE LOOP
ZEPHYRHILLS FL 33542-2203 7ust Value $4,373
Assessed (Non-School Amendment i) $4,373
Legal Description (First 4�ines)
See Plat for this Taxable Value $4,373
Subdivision
WALNUT GROVE TOWNHOUSES
PB 69 PG 054
LOT 24
OR 6544 PG 1916
7urisdiction
City of Zephyrhills
Land Detail (Card: 001 of 001)
Line Use�Description�Zoning Units Type Price ,Condition V lua e�
1�^ 0100 C SFR M UD � 2,750.00 SF $1.56 j 1 00 $4,290
2 ��� 0100 � SFR� MPUD � 1,650.00 ^ �SF� $0.05 ����1.00 � $83
Additional Land Information
----- FEMA ,---_._._�. __�__�___._�_�.—_
Acres � 0.1�Tax Area� 30ZH I Code � X � � Residential Code WGTHLPI
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
Extra Features (Card: 001 of 001)
Line � � �Description �Year �nits _`_ IValue �
No Extra Features
Sales Historv
Previous Owner: N/A
Month/Year Book/Page ype DOR Code ,Condition �pmount
08/2005 � 6544 / 1916 � Warranty Deed_ _� Vacant � $6� 00,000
11/1981 1157 / 1702 � _ �__ __�--i � � Vacant { $130,000
01/1973 0707/ 0675 � � Vacant � $0
http://seazch.pascopa.com/parcel.aspx?parce1=2126150210000000240 10/6/2017 i
• � : 37851 prairie Rose
o umn
SQ. FEET PRICE
UNDER ROOF: 1,872 $ 112.65
OTHER: - $ -
VALUATION $ 210,880.80
FEE SHEET $ 821.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 917.42
ELECTRICAL: $ 184.73
PLUMBING: $ 123.15
MECHANICAL: $ 86.21
SUB-TOTAL $ 1,311.50
TOTAL $ 1,317.50
SEWER: $ 2,010.00 � '
WATER: $ 641.00
IRRIGATION: $ -
TOTAL: $ 2,651.00
WATER METER: $ 473.78
IRRIGATION METER
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 4,989.63
PARK IMPACT FEES $ � 769.56 I
SIF'S: I'
100.0% $ - �
1.0% $ - I
TOTAL: $ ' I
T I F'S: $ 3,632.00 I
99% $ 3,595.68 �
1% $ 36.32 �
TOTAL: $ 9,391.19
. . ' Prairie Rose Lp It 24- Bailey Contracting 1,872 sq ft-Townhome-
• ' 37851 Prairie Rose Lp
o umn
SQ. FEET PRICE
MAIN OR LIVING: 1,872 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
' OTHER: - $ -
VALUATION $ 210,880.80
FEE SHEET $ 821.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
- BUILDING: $ 917.42
ELECTRICAL: $ 184.73
PLUMBING: $ 123.15
MECHANICAL: $ 86.21
SUB-TOTAL $ 1,311.50
TOTAL $ 7,317.50
SEWER: $ 2,010.00
WATER: $ 641.00
IRRIGATION: $ -
TOTAL: $ 2,651.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: $ 104.20
INSPECTION TOTAL: $ 12.50
PERMIT TOTAL
TOTAL: $ 116.70
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 5,106.33
PARK IMPACT FEES $ 769.56
SIF'S: �
100.0% $ -
1.0% $ -
TOTAL: $ -
T I F'S: $ 3,632.00 �
99% $ 3,595.68
� 1% $ 36.32
TOTAL: $ 9,507.89
- -- I
�� .
4 r
FORM R4Q5-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Prafessiona! Regulation - Residential Performance Methad
Project Name: R0617256 Unit 8-1 and 8-6 Buiider Name: Buttertield
Street: 4�6t3-C-e�E-..,t-- '3^7 rOs( �r�,�c`t-2G'^S�- L� permit Office: City of Zephyrhills
City,8tate,Zip: Zephyrhil3s,F�,33542 Permit Number: t t�ct a3
Owner: Typical-End Units 8-1 and 8-6 Jurisdiction: 611600
Qesign�ocatian: Fl.,Tampa Caunty:: Pasco{Florida CNmate Zone 2)
1. New canstruction or existing New(From Plans) 9. Wall Types{1085.3 sqft.) Insulation Area
2. Singie famity or mulfip(e famiiy Singie-famiiy a.Concrete-Block-Eact Insu1,�teriar R=5.0 898.67 ft2
b.Frame-Wood,Adjacent R=13.0 186.67 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d'N1A R= ft2
5. Is this a worst case? Na 10.Ceiling Types (1435.0 sqft.) Insulation Area 2
a.Under Attic(Vented} R=30.0 1435.00 ft
6. Conditioned floor area above grade(ft�} 1435 b.N/A R= ft2
Conditioned floor area below grade(ft� 0 c.N/A R= ft2
11.Duc#s R ftz
7. Windows(137.0 sqft.} Description Area a.Sup:Attic,Ret:Attic,AH:ah 6 175
a.�U-Factor• Dbl,U=0.30 137.00 ft2
SHGC: SHGC=0.25
b. U-Factor• �. N/A g= 12.Cooiing systems kBtWhr Efficiency
SHGC:� , a.Central Unit 27.8 SEER:14.00
c. t1-Facto"r: NIA ft2
�- SHGC: ;�' � 13.Heating systems kBtu/hr Efficiency
d. t1-�actar� ' ';` NIA ftZ a.Electric Strip Heat 27.3 COP-1.OQ
''�' SHGC: � �
. =�..,•,.s
w-'�J Area�Weighted Ave�:�ge Overhang Depth: 1.672 ft.
. - Rrea Viteighted,A`ve�s�e SHGC: p,2�p 14.Flot water systems '
`#°-� " a.Electric Cap:40 galions
8. Floor T'}ipes (1435;i>°sqft.) Insulation Area EF.0.970
a.Slab-On-Graiie E%ge insulation R=O.Q 1435.Ofl ft2 b. Gonservatian features
b.N/A � '- � , R= ftZ None
c.N/A � , .' . '�•;;�; R= �2 15.Credits _ CF,Pstat
. y:;
-�". ` `'�,� Total Proposed Modified Loads: 46.63
Glass/FloorArea: ,..O.q95 PASS
:} Tatal Baseline Loads: 46.58
4:. ; �
r .,c k,;;• � ;. .
. ' : ..n�n' ., . � ' ' .
` I,he,rei�y�eertify that the plans and specifications covered by Review af the ptans and �����`��,�
tfiis;,,�cafculation are in compliance with the Flarida Energy specificatiqns covered by this 4� f,f ,�� t��,
Code. � - calculation indicates compliance '� �' �-�,;�. .c�
� f r� a �`
d��.�f�� with the Flarida Energy Code. �:"�rr�r�?�J;z�:�,,,� , +Q
PREPARED BY: �'i Befare construction is completed �
4f�_ .. �1
DATE: �6-��-» tftis building witl be inspected for � : �'���� �.
compliance with Section 553.908 ,. .� � ,
I hereby certify that this building,as designed,is in compliance Florida Statutes.
with the Florida Energy Cade. �����'���
OWNER/AGENT: BUI�DlNG F IAL: '
DATE: DATE:
- Compiiance requ��es certifcation by the air handler unit manufacturer fhat fhe air handler en Iasure qualifies as
certified factory-s::aled in aacordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation lnspection Checklist in accordance with R4Q2.4.1.1 anc!art envelope leakage
test cepart in acaor�iance with R402.4.1.2.
6/27/2017 5:50 AM EnergyGaugeB USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
° :�
��
* FORM R405-2014
PROJECT
Tiile: R4B17256 Unit 8-'!and 8-6 Bedrooms: 3 Address Type: Street Address
Buiiding Type: User Conditioned Area: 1435 Lot#
Owner. Typicai-End Units 8-1 and 8- 7otal Stories: 1 Block/SubDivision:
#af Units: i Warst Case: No PlatBaok:
Builder Name: Butte�eid Rotate Angle: 0 Street: 4408 Court St
Permit Office: City of Zephyrhills Cross Ventilation: No County: Pasco
Jurisdiction: 611600 Whole Hause Fan: Na City,State,Zip: Zephyrhi(Is,
Family Type: Single-family FL, 33542
NewlExisting: New(From Plans}
Comment:
C�.tMATE
j � lEGG Design Temp int Design 7err�p Heating Design Daily Temp
�I Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL TAMPA INTERNATI 2 39 S'f 7Q 75 645.5 54 t�lledium
BLOCKS
Number Name Area Volume
1 Entire Unit 1435 'I14$0
spACEs
Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated
9 Master Bedroom 22d 17&d No 2 i 1 Yes Yes Yes
2 Mtlt 19 152 Na 0 1 Yes Yes Yes
3 Master Bath 93 7A4 No d 1 Yes Yes Yes
4 Mwic 39 312 No 0 1 Yes Yes Yes
5 Kitchen 156 1248 No 0 1 Yes Yes Yes ,
6 Bedroom3 150 124Q No 4 1 1 Yes Yes Yes
7 ah 12 96 No 0 1 Yes Yes Yes
8 Laundry 40 320 No 0 2 Yes Yes Yes
9 Bath2 44 352 No 0 1 Yes Yes Yes
1Q Bedroam2 131 'lQ48 M1ta 1 1 9 Yes Yes Yes
11 Entry 58 464 No 0 1 Yes Yes Yes
12 HaII 79 632 No ,� 0 1 Yes Yes Yes
13 Great Rm Dining 394 3152 No 0 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perime#er R-Value Area Joist R-Value Ti1e Wood Carpet
1 Slab-Qn-Grade Edge Insulatio Master Bedroom 30.7 ft 0 22p ft' ____ 0 1 (1
2 Slab-Qn-Grade Edge Insuiatio Mtlt 1 ft 0 19 ft� __r p 1 0
3 Saab-On-Grade Edge Insu)atio Master Bath 1 ft 0 93 ft2 ____ 0 1 0
4 Slah-pn-Grade Edge Insulatio Mwic 1 ft 0 39 ftz _� 0 'I 0
�
6/27/2017 5:50 AM EnergyGauge�U8A-FlaRes2014 Section R445.4.1 Gomptiant Software Page 2 of 5
�
Y� FORM R405-20'14
FC.OQRS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
5 Slab-On-Grade Edge Insulatio Kitchen 1 ft 0 156 ftZ ____ 0 1 0
6Stab-dn-�rade Edge Insu(afio Badroam3 94 ft 0 'i5d ftz ____ d 1 0
7 Slab-On-C,rade Edge lnsulatia ah 1 ft 0 12 ft2 ____ 4 1 Q
8 Slab-On-Grade Edge Insulatio Laundry 1 ft 0 40 ftZ ____ 0 1 0
9 Siab-On-Grade Edge insulatio Bath2 T ft 0 44 ftZ ____ 0 1 0
10SIab-C}n-Grade Edge lnsulatio Bedroom2 23.7 ft 4 134 ft2 ____ 0 9 0
11Siab-On-Grade Edge Insulatio Entry 5 ft Q 58 ftZ ____ 0 1 0
12SIab-On-Grade Edge Insulatio Hall 1 ft 0 '79 ftz _�_ 0 1 0
13Siab-On-Grade Edge insufatio Great Rm Dining 39 ft 0 394 ftz _�_ 0 1 0
ROOF
J Roof Gable Raof Solar SR Emitt Emitt Deck Pitch
# Type Materials Area Area Colar Absor. Tested Tesfed InsuL (deg)
1 Gab1e or Shed Gampositioa shingfes 1512 ft2 238 ft2 Medium 4.65 tVo 0.9 tVo 0 18.4
ATTIC
V # Type Ventilation Vent Ratio(1 in} Area RBS 1RCG
1 Ful!attic Vented 300 1435 ft2 N N
CEILING .
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) ' Master Bedroam 30 Blown 220 ftz 0.1 Wood
2 Un�er Attic{Vented} MfEt 3d Blawn 19 ft2 0.1 Wood
3 Under Attic(Vented) Master Bath 30 Blown 93 ft2 0.1 Wood
4 Under Attic(Venfed) Mwic 30 Blown 39 ft2 d.1 Wood
5 Under Attic(Vented) Kitchen 30 Blown 156 ft' 0.1 Wood
6 Under Atfic{Vented} Bedroam3 30 Blown 15Q ftz 0.9 Wood
7 Under Attic(Vented) ah 30 Blown 12 ftz 0.1 Wood
8 lJnder Attic{Vented) �au�dry 30 Blawn 40 ft' 0.1 Woad
9 Under Attic(Vented) Bath2 3p Blawn 44 ftZ 0.1 Wood
10 UnderAttic{Vented} Bedraom2 30 8lowrr 939ftz 0.1 Wood
11 Under Attic(Vented) Entry 30 Blown 58 ft� 0.1 Wood
12 Under Atfic{Vented) Hai1 30 Blown 79 ft� 0.1 Wood
13 Under Attic(Vented) Great f2m Dining 30 Blawn 394 ft' p.1 Wood
� 6/27/207 T 5:50 AM EnergyGangeQ USA-FlaRes2014 Section R405.4 1 Compiiani Software Page 3 af 5
'� FORM R405-2014
{NALL.S
Adjacent spa�� Cavity Width Height Sheathing Framing Solar Befo w
1 N Exterior Concrete Block-F�ct In3r6�ster Bedro 5 14 8 8 0 117.3 ft2 0 0 0.3 0
2 E E7cterior Goncrete Block-Ext In��ster Bedra 5 ' 8 0 8 4 B4.0 ft2 0 4 0.3 0
3 W Exterior Concrete Block-F�ct In�ddster Bedro 5 8 Q 8 0 64.0 ft2 4 0 0.3 0
4 W E�erior Co�crete Block-E�Ins�edroom3 5 '14 0 8 Q 112.0 ftx 4 0 0.3 0
5 S Exterior Concrete Block-Ext Ins�edroom2 5 12 0 8 p 96.0 ftz 0 0 0.3 0
6 W Exferior Cancrete Biock-E�ct 1ns�edraom2 5 41 8 8 0 93.3 R2 d 0 0.3 0
, 7 S Exterior Concrete Block-F�ct Insul Entry 5 5 0 8 0 40.0 ft2 0 0 0.3 0
8 N Exteriar Goncrete B1ock-�ct In�teat Rm"Din 5 14 0 8 0 112.0 ft2 0 0 d.3 0
9 W Exterior Concrete Block-Exct In�teat Rm Din 5 25 0 8 Q 200.0 ft2 0 0 0.3 0
_9 Q S �arage Frame-Woad Entry 13 9 4 8 8 4 93.3 ff2 0 0 0.41 0
_11 S Garage Frame-Wood Bath2 13 6 4 8 0 50.7 ft2 0 0 0.01 0
_12 S Garage Frame-Wood �.aundry 13 5 4 8 0 42.7 ft2 0 0 d.di 0
DQQRS
# Omt Door Type Space Storms U-Value Width Height Area
Ft tn Ft !n
1 S Insulated Entry None .35 3 6 $ 20 ftZ
2 N Insulated Great Rm Din None .35 3 B 8 2Q ft2
' 3 S insulated Entry None .35 2 8 6 8 17.8 ft=
WIND0INS
4rientation shown is the entered,Pro osed orientation.
j 11�?ail Overhang
V # Ornt (D Frame Panes NFRC U-Factar SHGC Area Depth Separation Int Shade Screening
1 N 1 TIM Low-E Double Yes Q.3 0.25 30.0 ftZ 1 ft Q in 't ft 2 in Drapesibtinds Exierior 5
2 W 4 TIM Low-E Double Yes 0.3 0.25 15.0 ft' 1 ft 0 in 1 ft 2 in Drapes/blinds Eacterior 5
3 S 5 TiM Low-E Double Yes 4.3 Q.25 ZQ.O ft= 1 ft 0 in 1 ft 2 in Drapesibiinds Exterior 5
4 W 6 TIM Low-E pouble Yes 0.3 0.25 15.0 ftz 1 ft 0 in 1 ft 2 in Drapes/blinds E�cterior 5
5 N 8 TIM Low-E Doubie Yes 4.3 0.25 12.0 82 8 ft 8 in 1 ff 2 in Drapesiblinds EScterior 5
6 W 9 TIM Low-E Double Yes 0.3 0.25 15.0 ftz 1 ft 0 in 0 ft 9 in Drapes/blinds E�erior 5
? W 3 TtM Low-E Double Yes 0.3 0.25 30.Q ftZ 1 ft 0 in 1 it 2 in DrapeslbJinds F�cteriar 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wali Insulation
1 234 ft2 234 ft2 64 ft 8 ft 1
INFILTRATION
# Scope Method SLA CFM 5Q ELA EqLA ACN ACH 50
1 Wholehouse Proposed ACH(50) .p00356 1339.3 73.53 138.28 .2669 7
�
6/27l2017 5:54 RM EnergyGaugefl tJSA-F1aF2es2014 Section R405.4 1 Compliant Saftware Page 4 of 5
�'r FORM R405-2014
HEATIiVG SYSTEM
# aystem 7ype Subtype Efficiency Capacity BJock Qucts
1 Eiectric Stnp Heat None COP•1 27.3 kBtu/hr 1 sys#9
' COOLING SYSTEM
# System 7ype Su6type E�ciency Capacity Air Flow SHf2 Block Ducts
1 Central Unit Split SEER: 14 27.8 kBtu/hr cfm 0.75 1 sys#1
HOT WATER SYSTEII�I
# System Type SubType Lacation EF Gap Use SetPnt Conservatian
1 Electric None Garage 0.97 40 gal 60 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Coilector Storage
Cert # Gompany Name Sysfem Model# Collector Model# Area Volume FEF
None None ft2
aucTs
/ --Supply--- ---Return-- Air CFM 25 CFM25 HVAC#
\� # Location R-Value Area Locatian Area Leakage Type Nandler TOT OUT QN RLF Heat Coo!
1 Attic 6 175 ftZ Attic 75 ft� Default Leakage ah (Default) (Default) 1 1
TEMPERATURES ' •
Programable Thermo�>tat:Y Ceiling Fans:
Coolin Jan Feb Mar A r Ma X Jun X Jul X Au X 8e Oct Nov ]Dec
Heatins EX�Jan �X�Feb �X�Mar E �AAr � �MaY � �Jun � �Jul �Au9 f �Sep E �Oct f X�Nov f X]Dec
Ventin f Jan ( Feb [X Mar [X A r Ma Jun Ju! Au t Se IX Oct [X Nov t �Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 i0 11 42 �
Cooling(WD) AM 78 7$ 78 78 78 7$ 78 78 80 80 80 80
PM SO 80 78 78 78 78 '78 78 78 78 78 78
Coo(ing(WEH} AM 78 78 78 78 78 78 78 78 78 78 '78 78
PM 78 7$ 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 fi$ 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 6$ 68 68 68 68 68 68
PN1 68 68 88 68 68 88 68 68 B8 68 66 Bfi
1
6/27l2017 5:50 AM EnergyGaugeC�USA-FlaRes2044 Section R405.4 1 Compiiant Software Page 5 of 5
(
J FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerFormance Index,the more e�cient the home.
4408 Court St, Zephyrhills, FL, 33542
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insui,Exterior R=5.0 898.67 ft2
b.Frame-Wood,Adjacent R=13.0 186.67 ftz
3. Number of units,if multiple family 1 c.N/A R= ft=
4. Number of Bedraoms 3 d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types Insulation Area
a.Under Attic(Vented) R=30.0 1435.00 ft'
6. Conditioned floor area(ft') 1435 b.N/A R= ft'
7. Windows'* Description Area c.N/A R= ft
:
a. U-Factor: Dbl,U=0.30 137.00 ftZ 11.Ducts R ft=
a.Sup:Attic,Ret:Attic,AH:ah 6 175
SHGC: SHGC=0.25
b. U-Factor� N/A ft'
SHGC: 12.Cooling systems kBtu/hr Efficiency
c. U-Factor• N/A ft2 a.Central Unit 27.8 SEER:14.00
SHGC:
d. U-Factor: N/A ff� 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Strip Heat 27.3 COP�1.00 �
Area Weighted Average Overhang Depth: 1.672 ft.
Area Weighted Average SHGC: 0.250
8. Floor Types Insulation Area 14 Hot water systems
� a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1435.00 ft EF:0.97
b.N/A R= ft=
c.N/A R= ft: b. Conservation features
None
15.Credits CF,Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building �,���x�.
Construction through the above energy saving features which will be installed(or exceeded) ,,�,� =�c� _
in this home before final inspection. Otherwise, a new EPL Display Card will be completed ��",;,f'"�� '�=.�, ''�'�
based on installed Code compliant features. � r_u'uir ,'�;���`'"„�
Builder Signature: Date: � i`���" � �
� � k
Address of New Home: City/FL Zip: �.�, - �5.
'�iD���'�'.
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)`
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/27/2017 5:51 AM EnergyGauge�USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
' PAS�t� C�UI�1`Y, ��.oRia� �
e . ., .
� � �
. .. Permit No. �__� �
Date Permitted � ,�
Buiider NamelOwner Name ���t ���-- f'r�?�5't Control#
S-� -2 2�� f0-OOQOd- `�o SubDiv: �l.�tht�.7"�r��,
Caunty Parcei No. � 2 -6
Address/Locatian �j 7� �� � �+"��'i�.- K�1 Se--t�
C(assificat(onfi'ype of Usa ������
7RANSPORTATION IMPACT FEE � Rate: Sq.Ft Unit: �7�.
Exempt []Yes ❑ No No�v Determined
' ic►zpact Fee Amount $ 3��a 2� Zane No. TAZ:
SCHOQL iMPAGT FEE
Account (056) Single-Family Detached House Amount $ r�'�
{057j Mobile tiome
(058) Otrier Restdenttai
123} Collect(on Fee
Eacempt []Yes [l No How Detercn(ned
PARKS AND RECREATION FEE
land Account Land Credit Land Total
Recreation Account Recreation Credit �Recreatton Totai
Zane TOTAL AMOUNT $ ����-J�,C
Exempt []Yes ❑ No How determined.
UBRARY FEE
Land Account Land Credit Land Tota)
Facitity Account PaciBty Gredit FacilEty Tota1
Exempt ❑Yes ❑ Na Now Determined Total Arnaunt ����'"� },
RE50URCE FEE ERU
TOTAL AMOUNT � �
Prepared By • Checked By }
i
;
NO CERTIFICATE OF QCCUPANCY WILL BE tSSUED OR FlNAL IIdSPECTtON �,
PERFORMED UI�ITIL,THE TOTAL AMOUNTS LiSTED HAVE i
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTlNG OFFICE OP PASCO COtlN'FY
i
3
Acknowiedgement below does not tmpty accaptance of concutrsnce,but simpiy recelpt of a copy of this form,ptacing �
the buiiding pertntt owner an notice of this assessmsnt and tha conditlons of payment for same. 4
t
DATE RECEIVED BY
RECEiPT NO. DATE BY
� 1
C
t
{
. . . .. {
6
___-�.._._..�_..�.. _�-:_._ .s..:..'.. -�--�.—.� ..,_-_-' '_
• 5335 - 8TH STREET �
- , � (813)780-0020
CERTIFICATE OF OCCUPANCY
Address: 37851 PRAIRIE ROSE LP LT 5 Owner: BUTTERFIELD MOBILE HOME SVC INC
ZEPHYRHILLS, FL. 38930 BUTTERFIELD LN
Subdiv: WALNUT GROVE TOWNHOMES ZEPHYRHILLS, FL. 33542
Parcel: 15-26-21-0210-00000-0240 Work Type: 105-NEW CONST/MULTI 5+ UNIT
Construction Type: NOT APPLICABLE ❑ Sprinklers
Use Classification: NOT APPLICABLE
Permit Number: 18903
Dat : � � 4/05/2018
�
ISSUE Y: BUILDI OFFICIAL :
WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE
GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE
Jacqueline Boges
From: , Nichole Spence(FATHOM)<support@gwfathom.zendesk.com>
Sent: Tuesday, October 17, 2017 12:17 PM
To: Jacqueline Boges
Subject: [FATHOM] Re: 37851 Prairie Rose Lp
##- Please type your reply above this line -##
Your request (#170536) has been solved. TO REOPEN THIS REQUEST, reply to this email or click the link below:
https://gwfathom.zendesk.com/hc/requests/170536
___ �
�_� -; Nichole Spence (FATHOM)
L-�j---' Oct 17, 9:1 7 AM MST
Service order# 608793 created for meter install.
Best Regards,
Nichole � FATHOM Support
r '� � Nichole Spence (FATHOM)
`-��- �-� Oct 12, 1 1 .24 AM MST
Account # 2618509 has been created, service order to follow once mapping has been
completed.
Best Regards,
Nichole � FATHOM Support
C �_ > ' Jacqueline Boges
` -----' Oct 12, 10.20 AM MST
new construct townhome sewer and water services
' This email is a service from FATHOM.
i
I