Loading...
HomeMy WebLinkAbout17-19173 CITY OF ZEPHYRHILLS 5335-8TH STREET . s (sis)�sa-ooza 19173 FIRE SPRINKLER$YSTEM PERMIT ' PERMIT INFORMATION` � LOCATIO.N INFORMATION Perrriit Number: '19173 Address: 6Q3Q GALL BLVD Permit Type: FIRE SPRINKLER SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE-SPRlNKLER SY� Tawnship: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivisian: CITY OF ZEPHYRHILLS Est.Va[ue: Parcel Number: 03-26-2'I-0010-12800-0000 Improv. Cost: 12,990.00 OWNER INFORMATtON Date Issued: 110812018 Name: GAL.� BdULEVARD �AND TRUST Total Fees: 225.00 Address: 350 HARBOR PASSAGE Amount Paid: 225.OQ CLEARWATER, FL. 33767 Date Paid: 1/08/2018 Phone: Wark Desc: MODIFlCATION TO SPRINKLER SYSTEM -BEALS OUTLET CCINTRACTO►R S APPLICATiON FEES PIP R FI PR�ECTI�J I C- OHN FIRE SPR KL SYS 50.00 FIRE INS ECT N FE 5.00 FIF2E PLAN REViEW FEES �aa.oa CONTF2ACTOF2 CERTIFICATE 34.Q0 r � -� � � � C,��-�� 3�.ST6 tns ectians Re uired FIRE-PRE SURE E T FIRE AGCEPTANCE Final Chapter 633, Florida Statutes,authorizes the City to charge and callect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan reviewj aclministrafiive fees,and othec costs related ta the aforementioned, Complete Plans� Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshai or required permits ar apening up for cammercial activity without an approved final inspecCion shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shaEl be performed in accardance with City Codes and drdinances. "WARNTNG TO OWNER: YOUR FAILURE T4 RECORD A NOTICE OF C4MMENCEMENT MAY RESULT IN Yf3UR PAYING TWICE FOR IMPROVEMENTS TO YOUR PRC?PERTY. IF YOU INTEND TU QBTAIE�f FINANCING, CONSULT WITH YOUR LENDER OR AN A7TORNEY BEFORE RECO DING Y#'�UR NCITICE OF COMMEN ENT." l, `�— CONTRACTOR SIGNATURE PERMIT OFFlCE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FQR INSPECTION - 8 HOURS NO'I`ICE lPEQUIRED ZEPHYRHILi.S FIRE RESCUE DEPT- 813-780-0041 sas-7aa-ao2o � City of Zephyrhiiis Fire Fax-813-780-0021 � � ��� Permit Application late Received � ���.,'2"�'�' ("�,� I Phone Contact for Permit ('� � tr-;,"'---•��_n..,.-;a7:_.....s_:.:�.z�.. „. i�... ....._ ., r�si.�:;.�=t-""".<�.;a9r..��.3.��..s-�_v._ . __..,. :.r..s:-'�.",'"..........��"s'S$FSf.;�:nr'c.,A-. , L��.�..� �ix:w`:.`1%F�.:.`...�_no...+v_ �>3..ri.^«L�..�."..NaL'.r:_✓+...%��r'i}L::iAt`i+�Mii:.i4:L�.ia' �Y.G^.M-.�cr^= Jwne�s Name �- � �,L �rwner's Phone Number ' C_� � �� hvne�s Address ��� (�� .��..��� �„ �,3?�j - ee Simple Titleholder Name Tltleholder Phone Number U �� � ee Simple Titleholder Address . ...-,,:.�c_3."`�":::...=t:.`_iS':'?':"_<'5:7�`xs:�.i%..e ...'�t.:s:�>j.i?.�wsi.ati3'.'= 'iC..3..`'t:r.--�.--.�vr�-.caz-�--.z:•, +=.:-�_ :+,r;:-�-->��c. pT>�,•,-_�,- . ' .,��: ' v�. -�..+,,:..'�".�'_-..zp-^-.�;«x""' _Tn_.�-�'-.�-:.�xi .'-.>`'�`�'».;.i:.::-'�-,�s.,.....:r - •4::....=asii..'�'"�.�.-`_�.•-=. ob Address � �� �. jx u��,� �� �= Lot# �ub Divisian Parcel# F».`<.r.:a5`::��"t'its.-:,.�, ,s:c "�'�T.s..'s'.�a..>v..u:.v�u� ' ^' 'x-,�.�,i,a.c�?w.., _ ,_ 'w"•.i�>. .. w�=_n'::.7v:7k:f�=„zx:`l..^�..-..:_.. � - �� '. . ,.2.-,..._.,...: � .;:_:1::-."^..Cii:.'.,:::&'_'..:;i:#.�"'„�.:..,�":a"y;.3:.���^.::....'t:..::�.a.':_,,..y.n..w.."r:.,��"'��c:�a.�:�`_.�".�.,'r'�.�__<,x....�.�..s.":=�lr:?:X�%:f.�•."f'?'-:""»", . ' ' ':ti r Bio-Hazard Waste Storage-ANNUAL � Fumigation Tenf � Comm Exfiaust Kitchen Hood/Duct Q hiazardous Materiai(Tier II or RQ Facility)APINUAL , � Cantrolled Bum � Hood lnstailation � Emergency Generator<30 kw � LP/Natural Gas-Installation � Emergency Generator>30 kw � LPlNaturai Gas-At@tdUAL Sa{e � Fire Protectian Maintenance-ANNUAL Q Places of Assembly-ANNUAL ❑� emi � er (9j��� Sprinkter C) O ❑ � � Recreational8um � � t Fire Alarm � ❑ ❑ ❑ � � Sparklers �.�. t � Hood Cleaning � ❑ , ❑ ❑ �� �SprinklerSystem instaiiations �j'C� � Hood Suppression � D D ❑ � � Standpipes{8prinkler Sys) � Fire Alarm Instaltation � Tarch Roofing/Tar Kettle ' � Fire Pumps o Waste Tire Storage,4P!ldUAl. � Fiammabie App(ication-At�NUAL Z , Valuation of Project Fuel 7anks Q Other: .�>. _�t__�...,;_...._< .,..�.,. +=^.:..'Y3..._•v.`.;:L".'Si.r.�;:'rGw:-�,,,;< '�^ .�..f..:e'-m•- w,•>. _ ' _ ' � � A -. ..,.`�-.a;.s�..ctr�..!« ..�c.�,:;w.2..>S:'.:.�w��r�«�r.�.::4'S:�':''.e!s..`.ii"u'�xd�...�a.+..�.... .��� .�.r_��-�.m_-..:._:���.,.'�..� - " - ' - -.a.:.,:.. .. P:s��..�...-. ..r�,�..M,:r..�._.�,.......-._r.-. " -._�+.:..r -' : -�,�r�:=.,T2.k:.�.�.iY,,.�"�.�..r '+�r-�'.-::x"�x. "�"Y-;�!.^.x-..;;xn+.-... ,..� , ...,... ,,,.. ., -:..-.,.., ;...�"�ir»"=��;>_' �'"."'.:�'...A.a_..�r,;....�,�'i-`, :orttractor . Company � � � iignature Registered � N Fee Curtent Y/1� Address license# �3�}7j(� j :I.ECTRICIAN Company >ignature Registered -Y 1 N Fee Current Y/N Address License# 'LUMBER Company >ignature Registered Y/N Fee Gurrent Y/1�! Addeess License# dECNANIGAL Company aignature • Registered Y/N Fee Current Y/N Address LkCSTSSE# �THER Campany iignature Registered Y i N Fee Cutrent Y 1 N Address ,_,.:.,.,•�.n,.• __ . _,,; .,,.. :;:�.,��_.....,r:.�_..a_r.;�.�,� .,.., .��:� p„s:•::>.:,.-�:�e,. - - - ,..:s:_:. :�.-�._=.:,s_=, - ��:...., _. .J:_Y:...c.�...-,.3 -..:.t,'x.,._._.y-,.r.-+_i��:-.:r-::{.^..:4i���Y<`:�"v. �i�ectians: �..,...,.-:, 58�..� - .�.���.._.3.�_�__�,�_w.�a�...�.�,�..�.,.._._. ....� ,..,�:.., __...._,:.�-._.�._,... _,. „ ,._ .,_. :... ...�.._..,,...,._._. I Fili out appiication completely. Owner 8 Contractor sign back of application,notarized(Or,copy of signed contraot with owner) If over$25d0,a t�oiice of Commencemenf is required{Mechanical wark over$5000} Supply two(2)sets of drawings with applicable documentation Allow 10-14 days for review after submittal date. Parcel#-obtained from Property 7�Notice{httpJlappraiser.pascogov.com) i NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed°resVictfons° which may be more resMctive than County reguletions. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED COWTRACTORS AND CONTRACTOR RESPONSIBILIi7E�: ff the owner has hired a contractor or � , contractors to undertake work,they may be requfred to be Ifcensed In accordance with state and local regulatlons. If the contractor Is not Iicensed as required by law, both the owner and contractor may be cited for a misdemeanor violatlon under state law. If the owner ar Intended contractor are uncertain as to�what Iicensing requirements may apply-for 4he , • tntended work,ihey are advtsed to contact the Pasco County Bu(IdfnB Inspection Divisiori—Licensfng Section at 727-847- 8009. Furthemtore; ff the ovmer has hired a contractor or contractors, he is advised io have the contractor(s�stgn : portions of the"contrector Blocl�'of this application for wfiich they wlll be responsible. 1f you,as the owner sign as the contractor,that may be an Indication that he Is not properly licensed and is not entitled to permitting privfleges in Pasw • County. - ' TRANSPORTA710N IMPACT1U71LITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportatton Impact Fees and Recourse Recovery Fees may apply to the c�nstruction of new bufldings,change of use tn exisUng buildtngs,or expansion of existing bufldings,as specffied in Pasco County Ordinance number 89-07 and 90-07,as amended. The undetsigned also understands,that such fees,,as may be due,,Hn11 be fdentified at the flme of permftting. It fs further understood that TransportaUon Impact Fees and Resource Re�overy Fees must be paid prior to recelving a'certificate of occupancy°or flnal power release. if the project does not involve a certiflcate of occupancy or final power release,the fees must be paid prior ta pertnit issuance. Furthermore,ff Pasco County Water/Sewer Impact fees are due,they must be paid prior to permft issuance in eccordance with applicable Pasco County ord(nances. , CONSTRUCTION LIEN LA1AI(Chapter 713,Florida Statukes,as amended): If valuaUon of work is$2,500.00 or more,I certify that I, the appflcant, have been provfded wHh a copy of the 'Florida ConstrucNon Lten Lew—HomeowneYs Protection Guide'prepared by ihe Florida Department of Agriculture and Consumer ATfairs. If the applicant is someone other than the'owner°,I certiFy that I have obtained a copy of the above described document and promise fn good faith to �-- deliver it to the'owner'prior to commenceme�. CONTRACTOR'SIOYYNER'S AFFIDA►VR: I certify that all the Informatlon in this appllcation Is accurate and that all work un11 be done fn compliance wfth all applicable laws regulating construction,zoning and land development. Appiicalton ts hereby made to obtefn a permlt to do work and fnstellation as indicated. I certify that no work or Instailallon has commenced prlor to issuance of a permtt and that all work wtll be performed to meef standards of all lews regulating � • construction, County and.City codes, zoning regulaUons, and land�,development regulatlons in the jurisdiction. ( al'so certify that I understend that the regulations of otFier govemment agencies may apply to the intended work,and that it is my responsibtlity to identify what actions I must�ake to be in compffance. Such agencies Include but are not Ilmfted to: - Department of Environmental Protection-Cypress Bayheads, 1Netland Areas and Env(ronmentelly Sensitive Lands,WaterNVestewater Treatment ' - ' SouthwesE Florida Water Management District-Welis; Cypress Bayheads, WeUand Areas, Altering Watercourses. � - Army Corps of Engineers-Seavralis,Docks,Navlgable Watervvays. - Department of Health 8� Rehabllitative Servfces/Environmental Health Unit-Wells, Wastewater Treatrnent, Sepifc Tanks. • - US Environmental Protectlon Agency-Asbestos abatement. - Federal Aviation AutHority-Rurnvays. , � 1 understand that the foilowing restricUons apply 4o the use of fill:• - Use of fill is not aliowed in Flood Zone N"uNess expressly permftted. - If the flll material fs to be used in Flood Zone "A, ft Is understood that a drainage plan addressfng a 'compensating volume"will be submit�ed at time of permi8ing wh(ch is prepared by a professional engineer . • • licensed by the Stete of Flortda._ - If ihd flll materlal fs to be used in Flood Zone'A in wnnec$on wlih a permitted building.us(ng stem wall constFuotibn,I c:ertffy_ffiat flll wlll be used oniy to flll the area wfthin the stem wall. - If flll mffieriai is to be used in any erea, 1'certffy that use of such fill will not adversely affect adjacent propertles. if use oF fll Is found to edversely affect adJacent properties,the owner may be cited for violeling " the condiUons af the building.permit Issued under the attached perm�t appiication,for lots less than one(1) acre whlch are elevatetl by flll,en ehglneered drainage plan fs requhed. Ii I am the AGEM'FOR THE OWNER,I promise in good faith to inform the owner of.the permitting conditions set forth in this affidavft prior to commencing conshuction. I understsnd that e separate permit.may be required for electrical work, plumbing, signs,wells, pools,air conditioning; gas, or other installations not speeifically Induded in the epplicafion. A � permR issued shall be construed to be a license to proceed'inrith the work and not as authority to,violate,cancel,atter,or set aside arry provisions of the technical codes,nor shall issuar�ce of a pennit prever�t the BuOdirig Officlal from therea(ter . requiring e correction of�rrors in plans,construcfion or violaUons of any codas. Every permft Issued shall become irnalid unless the work euthorized by.such permft is commenced w(thin sbc momhs of permit issuance,or if work euthorized by the permtt is suspended or ebandoned for a perlod'of six(6)months after the Nme the work is commenced: An extension mey be requested, in writing,from the Buiidtng.Official for a period not to exceed ninety(90)days and will demonstrate )ustifiable cause for the extension. If work ceases for nlnety(90)consecutive days,th�Job is consfdered abandoned. - WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEAflEMT MAY RESULT IN YOUR PAYING 7WICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT VYITH YOUR LENDER OR AN A7TORNEY BEFORE RECORDIPIG YOUR NOTiCE OF COMMENCEMENT FI.ORIDA JURAT(F.S..117.03) OWNER OR AGENT COMRACTOF!, Subsalbed end svam to(or afHrtned)betore me 1hLs Su6svlbed end s�wm to(or effUmad)before me thls . �, ' by Who Islare personaity Mwwn to me or hesThave produced Whn Islere personally Imown to me or hasThave produeed as identlficatlon. as Identlfica8on. Nohary Pubiic Notary Pub�c Commission No. Commisslon No. Neme of Notsry typed,p�inted or atemped ' �Name oi Nolary�ped,printed or stamped � N0310E OF DEED RESTRICTtONS: 7he undersigned understands fhe#fhis permit may be subject ta"deed"resfricfians" . ' which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UN�ICENSED CONTRACT012S ANLt CONTRACTdFt RESPC}NSt81l.ITtES: If the owner has hired a contcactar ar contractors to undertake woric,#hey may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor uiolation under state law. If the owner or intended contractor are uncertain as to what ticensing requirements may apply for the intended work,they are advised to contact the Pasco Caunty Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contraciors, he is advised to have the contractor(s) sign partians of ttre"confractor Biock"of this app(icatian far which fhey will @e resportsible. Ef you,as the awner sign as the contractor,tfia#may be an indication thet he is not property licensed and is not entitled to permitting privileges in Pasco Counry. TRANSPQRTATI4N IMPACTiUTELiTlES lMPAGT AND RESOURGE RECOVERY FEES: The undersigned understands thaf Transpartatian Impact Fees and i2ecourse Recovery Fees may apply to the eonstruction of new buiidings,change of use in existing buildings, or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees,as may be due,wilI be identified at the time of permitting. It is further understaod that Transportation Impact Fees and Resource Recavery Fees must be paid prior to receiving a"certificate af occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore,if Pasca Couniy WaterlSewer impact fees are due,they mast be paid priar to permit issuance in accordance with applicabte Pasco County ardinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction �ien Law--Homeowners Protectian Guide"prepared by the Florida Department of Agriculture and Cansumer Attairs. If the applicant is someone other than the"awner",I certify that I have obtained a capy of the above described document and promise in good faith ta deliver it to the"owner"prior to commencement. . - CQNTRACTOR'S14WNER'S AFFIDAVIT: 1 cerfify thaf atl fhe i�formation in#his appCication is accura#e and that aii work wi��be done in compliance with all applicable laws regulating canstructian,zoning and land development. Application is hereby made ta obtain a permit to do work and installation as indicated. I certify that no work or i�stallation has comrnenced priar to issuance of a permit and that aJJ work wili be pacformed ta mee#standards of a!1 laws regulating construction, Counfy and Gty codes, zoning regu(ations, and land development regulations in the jurisdiction. 1 also certify that I understand that the regulations of other govemment agencies may apply to the intended wark, and that it is my responsibifity to identify what actions I must take to be in campliance. Such agencies inctude but are not limifed to: - DeparFmsnt of Environmenta( ProtecEion-Cypress Bayheads, Wettand Areas and Environmenta(�y Sensitive Lands,Water/Wastewater Treatrnent. - Southwest Florida Water Management District-Wells, Cypress 8ayheads, Wetland Areas, Altering Wafercourses. . � - Army Corpa of Engineers-Seawalls,Docks,Navigable Waterways. - � - Department of Health & E2ehabilitative Services/Environmental Health Unit-Wei(s, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. 1 understand#hat the follawing restdctions apply to fhe use of fill: - Use of fill is not allawed in Flood Zone"V"unless expressly permitted, - If the fill material is to be used in Flood 2one "A", it is understood that a drainage plan addressing a "compensating valume"wil!be submitted at time af permitting which is prepared by a praEessianat engineer (icensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall canstruction,1 certify fhat fi!I wi31 be used onty to fll the area within the stem wall. - If fill material is to be used in any area, t certify that use of such fill will not adversely affect adjacent properties. If use oP fill is faund to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached petmit appiication,for lofs tess than one{1} acre which are etevated by fitt,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing cons2ruction. !understand that a separate perrnit may be required far elecfrical work, ptum6ing, signs,weEts, poats, air conditioning, gas, or other installations not specifically included in the appiication. A permit issued shall be canstrued to be a license to proceed with the work and not as authority to violate,cancel, alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the 8ui(ding O�cial f�am thereafter requiring a carrection af errors in pfans,cans#ruction or viotafions of any codes. Every permii issued shall become invalid unless the work authorized by such permit is cammenced within six months of permit issuance,ar if work autharized by the permit is suspended or abandoned for a period of six(6)months after the time the work is cammencecl. An extension may be requested, in writing,from the Building Officia2 for a period nat to exceed ninaty{90}days and wi11 demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING Tfl OWNER: YOUR FAlLURE Td RECQRD A NOTtCE OF CQMMENGEMENT MAY RESULT IN YOUF2 PAYING TWtCE FdR tMPROVEMEIVTS TO YOUR PROPERTY. IF YOU 1NTEND TO dBTAIN FINANCING,CONSULT WITH YOUR LENDER QR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT '� F�oRioa.auRa,r�F.s.»7.oa � �i O E OR AGENT �—�� CONTRAGTOR j � bY ( �ed) e e t ` � Subscribed and s�warn to(or aHirme�before me this Y I o i are pers own ta me or haslhave produced Wtto islare personally knflwn to me ar hasfiave produced i as identficatlon, as identification. '' ,/" .�-- .,._, _,,,,,,,,,,, Notary Public Notary Public mmi ion No. Commisston No. Nam ary ry rinted or stamped Name of Notary typed,printed ar stamped I {� !.ri �"'�; APAtLOBERt.E ti ;� MY COMMISSION 9 FF 11185� EXPIRES:August 10,201g �R��. 9onded 7�w NWary PUNp Undenttit[K I `.�___.�...._,...._�..._.�F___.� _.__.,_�____. ... ... . .. . . .._.. ___-—. ._ � .. ,.. .,. ._ v.. d._,...._._e. -- - �� �- � - PIPER FIRE PEZOTECTI.ON INC._ � - - - _ _ ' -- - 13075 US Highway 19 North = __ � - - -- _- : - _ - - Clearwater,Florida 33764 _ _.. -_- _ __-_ - _ _ - = - � -- PHONE: 727-581-9339 FAX: 727-581-8332 _ - - .- = CONTRACTOR'S_MATERIAL AND-TEST CERTIFICATE FOR ABOVEGROUND_PIPING__.- � - PROCEDURE: :.: - - - " - -- - _ _ _ - _ - ° - ---- - UPON COMPLETION OF WORK,INSPECTION AND TESTS SHALL BE MADE BYTHE CONTRACTOR'S REPRESENTATIVE AND WITNESSED BYOWNER'S REPRESENTATNE(HEREINAFfER DEFINED AS PROPERTY OW NER).ALL DEFECTS SHALL BE CORRECTED AND SYSTEM LEFT IN SERVICE BEFORE CONTRACTOR'S PERSONNEL FINALLY LEAVE THE J06.� ._ A CERTIFICATE SHALL BE FILLED OUT AND SIGNED BY BOTH REPRESENTATNES. COPIES SHALL BE PREPARED FOR APPROVING AUTHORITIES,OW NERS AND CONTRACTOR IT IS UNDERSTOOD THAT THE PROPERTY OWNER'S AUTHORIZED REPRESENTATNE IS A LEGAL SIGNATORYAND FULLY REPRESENTATNE OF THE PROPERTY OWNER AND THAT BY THE PROPERTY OW NER'S OR PROPERN OW NER'S AUTHORIZED REPRESENTATNE SIGNATURE,THE PROPERTY OW NER ACCEPTS FULL RESPONSIBILITY FOR THE SYSTEM AS INSTALLED AND AGREES THAT IT IS IN COMPLIANCE W ITH THE APPLICABLE APPROVING AUTHORIII"S RE�UIREMENTS AND LOCAL ORDINANCES. NOTE:NFPA 13,10-2.2 MODIFICATIONS AFFECTING 20 OR FEWER SPRINKLERS SHALL NOT REQUIRE TESTING IN EXCESS OF SYSTEM PRESSURE. MODIFICATIONS THAT CANNOT BE ISOLATED,SUCH AS RELOCATED DROPS,SHALL NOT REQUIRE TESTING IN EXCESS OF SYSTEM WORKING PRESSURE. PROPERTY NAME: I BEALL'S OUTLET#542 oATE' _ __ -__-__ _ i PROPERTYADDRESS: C6030 GALL BLVD.ZEPHYRHILLS, FL 33542 ACCEPTED BY APPROVING AOTHORITY('S)NAMES i CITY OF ZEPIiYRFiILLS FIRE IVIARSHAL ADDRESS I Puws 5335 8TH STREET ZEPHYRHILLS FL 33542 INSTALLATION CONFORMS TO ACCEPTED PLANS: EQUIPMENT USED IS APPROVED IF NO,STATE DEVIATIONS r --'_- ----- -._s_ ._----— -___.__-•---- ------------- - ----- —-- --- 1 -- , HAS PROPERTY OWNER OR PROPERTY OWNER'S AUTHORIZED REPRESENTATIVE BEEN INSTRUCTED AS TO THE LOCATION OF CONTROL VALVES AND CARE AND MAINTENANCE N� OF THIS NEW EQUIPMENT? __ _i_ _ EXPLAIN"NO"ANSWERS: f V---•---- ---- +- - -------T-- ---- -__.-_ - ------------- - -- ------- -•----- � iAt time of close-outs INSTRUCTIONS HAVE COPIES OF THE FOLLOWING BEEN GIVEN TO THE PROPERTY OWNER OR PROPERTY � OWNER'S REPRESENTATIVE? 1. SYSTEM COMPONENTS INSTRUCTIONS N 2. CARE AND MAINTENANCE INSTRUCTIONS 3. NFPA 25 p EXPLAIN"NO"ANSWERS: iAt t1IT1@ Of CIOS@-OUtS T ` � � - -- _ —__,_a_� _,_ LOCATION OP SERVES BUILDINGS OR PORTION OF BUILDING: SYSTEM(S) Entire Building MAKE MODEL SIZE QUANTITY TEMPERATURE/STYLE TY -L 3211 1 2' PT, 5.6K 165°F 401 DEEP NDENT SPRINKLERS OR SPRAY NOZZLES TYPE OF PIPE: TYPE OF FITTINGS: � -� - - ___ ...��- - - - - -_- _ -_ ,- - - ----- - -- ----- - - F- ---- - - - ---- - PIPE AND FITTINGS SCH 10 GROOVE$SCH 40 THREAD CI, DI 8 MI THREAD AND GROOVED STEEL ROUGH-IN/NSPECT/ON: HYDROSTAT/C TESTING OR PNEUMAT/C TEST/NG HYDROSTATIC: HYDROSTATIC TESTS SHALL BE MADE AT NOT LESS THAN 200 PSI(13.6 BAR)FOR TWO HOURS OR 50 PSI(3.4 BAR)ABOVE STATIC PRESSURE IN EXCESS OF 150 PSI(10.2 BAR)FORTVJO HOURS. DIFFERENTIAL DRY-PIPE VALVE CLAPPERS SHALL BE LEFT OPEN DURING THE TEST TO PREVENT DAMAGE.ALL TEST DESCRIPTION '�OVEGROUND PIPING LEAKAGE SHALL BE STOPPED PNEUMATIC: ESTABLISH 40 PSI(2.7 BAR)AIR PRESSURE AND MEASURE DROP,WHICH SHALL NOT EXCEED 1 1/2 PSI(0.1 BAR)IN 24 HOURS.TEST PRESSURE TANKS AT NORMAL WATER LEVEL AND AIR PRESSURE AND MEASURE AIR PRESSURE DROP,WHICH SHALL NOT EXCEED 1 1/2 PSI(0.1 bar)IN 24 HOURS. WELDED PIPING L_ NO • IF YES.... DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY �_ N/A _, W ITH THE REQUIREMENTS OF AT LEAST AWS B2.1? DO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS QUALIFIED IN �_ N/A____ WELDING COMPLIANCE WITH THE REQUIREMENTS OF AT.LEAST AWS B2.1? DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISCS ARE RETRIEVED,THAT OPENINGS IN -- PIPING ARE SMOOTH,THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED,AND THAT THE [ _N%A __, INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED. ' CUTOUTS DO YOU CERTIFY THAT YOU HAVE A CONTROL FEATURE TO ENSURE THAT ALL CUTOUTS ARE RETRIEVED? I YES UNDERGROUND MAINS AND LEAD-IN CONNECTIONS TO SYSTEM RISERS FLUSHED BEFORE CONNECTION MADE TO SPRINKLER PIPING UNDERGROUND VERIFIED BY COPY OF UNDERGROUND TEST FORM ' N/A , OTHER: FLUSHED BY INSTALLER OF UNDERGROUND SPRINKLER PIPING I N/A ! __ ALLPIPINGHYDROSTATICALL:YTESTEDAT �-` ZOO PSI FOR' �HOURS- - - DRY PIPING PNEUMATICALLY TESTED: ( N/A _ ,�_- _ - ' ' _- _ - - .,EQUIPMENT OPERATES PROPERLY: � YES- : - � � - __ _ - - � - � _ -- , - - - --- —-- - - _ —-- - —-__-:._.- --�-- ---�-- — ------___--.a�_ ___ _TESTS '- IF NO,STATE REASON: r -- - - ' - _ - _- _ _ _ ! - - . - -_ - _ : _ - 2 =-- - -- —------ ---- - -- - --- -- - - --- ------ - -- ----�---- - -- " ,.-- MODIFICATIONS OF 20 OR FEWER SPRKS OR RELOCATED DROFS: � - _ � SYSTEM PRESSURE ONLY i N/q-�� � - � �-- - - BLANK TESTING NUMBER USED LOCATIONS NUMBER REMOVED GASKETS _ -------� -- -- � -�--- SFRINKLER CONTRACTOR: PIPER FIRE PROTECTION,INC. HYDROSTATIC OR PNEUMATIC TESTS WITNESSED BY: -- -- --- - - - ------------- -------- ---- ROUGH-IN, t HYDROSTATIC pROPERTY OWNER (PRINT NAME) SIGNATURE TITLE DATE TESTS OR -- -- -- -- - --- - -- — -- --- -- -, � o/ . PNEUMATICTESTS: A.�6h. S • i O WITNESSED BY SPRINKLER CONTRACTOR (PRINT NAME) SIGNATURE TITLE DATE LOCAL AHJ (PRINT NAME) f SIGNATURE TITLE DATE FINAL INSPECT/ON ' ALARM DEVICE OPERATINGTIMETHROUGHTESTCONNECTION ALARM VALVE OR TYPE MAKE MODEL MINUTES SECONDS WATER FLOW INDICATOR � DRY VALVE: Q.O.D. i MAKE MODEL SERIAL# MAKE MODEL SERIAL# Time to Vip Time water throu h test Water Air Pressure rrip point air �eached test Alarm O erated Pro erl DRY PIPE Q�.p 9 pressure pressure P p y OPERATING TEST connection• ouUeY in ec psi psi psi in ec Yes No W/OQOD With QOD IF NO,EXPLAIN , -measurea ttom[ime inspeccors tes[openeo�NrrA��oniy reqwres[ne ou-secona umi[auon in spearic sec[ions� OPERATION: IPNEUMATIC �ELEGTRIC__� HYDRAULIC � PIPING SUPERVISED � N/A�DETECTING MEDIA SUPERVISED IYES NO, DOES VALVE OPERATE FROM THE MANUAL TRIP,REMOTE,OR BOTH CONTROL STATIONS r---� --__i -- �_N/A_a� IS THERE AN ACCESSIBLE FACILITY IN EACH CIRCUIT FOR TESTING r� N/A r-- �-- - ' - -- --- — "- _ � __ DELUGE AND IF NO,EXPLAIN: - --f'�- ---- - - - -�{-- -' --- -----�-- PREACTION VALVES DOES EACH CIRCUIT MAKE MODEL OPERATE SUPERVISION OPERATE RELEASE LOSS ALARM OPERATE VALVE RELEASE MINUTES SECONDS LOCATION AND FLOOR MAKE AND MODEL SETTING STATIC PRESSURE RESIDUAL PRESSURE FLOW RATE PRESSURE pg� INLET PSI OUTLET PSI INLET PSI OUTLET PSI GPM REDUCING VALVE TEST DRAIN TEST WATER SUPPLY TEST CONNECTION RESIDUAL PRESSURE Wmi VALVE IN 7ES7 STATIC: PSI CONNECTION OPEN WIDE: PSI , rn�DitaUUC oATA HYDRAULIC DATA NAMEPLATE PROVIDED: NO DO YOU CERTIFYAS THE SPRINKLER CONTRACTOR,THATADDfTIVES AND CORROSNE CHEMICALS,SODIUM SILICATE OR DERIVATIVES OF SODIUM SILICATE,BRINE,OR OTHER CORROSNE CHEMICALS WERE NOT USED FOR TESTING SYSTEM'OR STOPPING LEAKS. YES REMARKS DATE LEFT IN SERVICE WITH ALL CONTROL VALVES LEFT OPEN � PIPER FIRE PROTECTION INC. ; FINAL ACCEPTANCE pROPERTY OWNER (PRINT NAME) S NATURE TITLE DATE TEST WITNESSED ' ' --' V-' �- - --- ---_ _ _ _ �_ �j BY: °� � d � SPRINKLER CONTRACTOR (PRINT NAME) SIGNATURE TITLE DATE i LOCAL AHJ (PRINT NAME) SIGNATURE TITLE DATE \ � _. , � �EP�i�'�Hl�.t�� F�R� ��PA�T`iVI��T 6907 Dairy Road, Zephyrhills, FL 33542 �iRE �ER�ICE I�SER FEES Occupancy No.: � P�an No.: Contractor. �� ?C-'�- �"�� ��z.�r:���r,� Business Name: i ��-�-•— s QV`���""'Er '� Billing Address: �3 c�'1� �s s � 9 � Business Acidress. 0 3� G.�-.� '3�-� C �`''�•��'�-°'� ��. Business Phone No.: Billing Phone No.: � Business Fa�c No.: Silling Fax No.: Contact: Contact: PLAM RfViEW FEES INSPEC7iON FEES EE FALSE/�LARM FEE ❑Site plan N/C Annual N/C Sprinkler $5 1stAlarm N!C 1']�5� D�utti-FamltylGommerciai .0$sf 1 st Re-inspection N/� S ' $50 2nd Alarm N/C d` pu (Minimum Charge$25.00 2nd Re-inspection $��00 Fire Rump $50 3rd Alarm N/C �p�°❑Plan Revisions D8� 3rd Re-inspecfian $250 Hoads $50 4th Alarm $100 ,�� 4kh Re-Inspection $500 Fire Alarm $50 5th Alarm $150 SPRIPdKLER SYSTENtS {Business clased untii LP�as $5Q 6fh Atamt $200 0- 5 H�—"556-�,. violations corrected) Natural Gas $50 NON COMPLIANCE $150 p us Heads SPRIN#CLER SYSTEMS Fuei Tanks- per�nk $60 TANDPIPE SYS7EM Hydro Undergrounds $45 Sparklers $10D � Per Riser $50 Hydrostatic Test $65 per system Fire Works $500 FtRE FUh1iP A ce est per sysiem Camp Fire $25 �Per Pump $100 $75 ConUalled Bum $100 FIRE ALAf2tdi SYSTEM NoodtDuct $50 8 0-25 Devices $50 FIRE ALARAA SYSTEM Place of Assembly $50 Mnual 28 plus Qevices $900 System Acceptance $54 Fire Profectian $25 SUPPRESSION SYSTEAAS Recall Acceptance $50 Flammable Application $50 Mnual Wet $5d OTHER Waste iire Storage $50 �nua� Dry $50 Fire WalUSrnoke Wall $15 per wall Generator<KW $100 - CO2 $5Q LP Gas $25 per tank Genetator>30 KW 150 Other $50 Natural Gas $25 persystem Hio-Hazard Waste $10D Annual KITCHEN EXHAUST , Fumigation Tenting $50 �NaodlDuc#s $50 Tent 985c10'ar greater $15 pertent Torch PoUApplied $50 OTHER Fire Pump $45 Haz.Materials $100 a,nuai 8 CP tnsta!lation Frer tank $50 Fire Suppression $30 Fuei Tank Installation $50 System Acceptance ❑ {Per Tank) $54 n Exhaust HoadiDuct $30 Natural Gas Installa0on $50 � Re-inspection DBL {Per System} {other tttan annuaij �Spray Booth $50 �Inspection scheduled UBL 8 and cancelled less than 24 hours 8 Construction Insp. N/C �� Emergency Vehicle As $50 FAi.SE ALARM PLANS 70T/#L� INSPECTIOId TOTI4L� PERMIT TOTAL �d TpTAL� GRAND TOTAL �+y."��������"�� ����.��� Camments: - Date: ,�H �lj Inspectar: • > nin • - '. s�H lii11111111[Illllllllll{I11111111111111{{I11�11111111i11111 s�oas�ossaz �017191152 ��� ...•'a o�-2s-a�-oo�a�2aoa0000 �'�� Permit No. Parte!ID Ma ��q(p ��W NQ710E OF COMMENCEMENT � �p Ftorida � State ct Coonzy af PBSCo � t1f THE UNDERSIGNED here4y gives notice that improvement v+�be made to attain real properry,and in accordance with Chapter 713,Florida Statutes, � the fodawing informalion is providad in fhis NoGce of CommencemenL �.i� i. Desdrptian of Property:Parx!Identitica5on No. ` {) so-�eiAaaress: 6030 Gall Bivd.,Zephyrhills,Flarida ►��" r 2, feneral Desaiption o(lmpmvemeni ��nor interior wait retocaGon,ceiling repiacement,checkstand replacement �c @ aD and associated MEPs. � r � �e 3. Ovmer IrdocmaUvn or tessee iMamat3on H ihe lessee contracied forlhe bnpmvet»enL• � 8eaii's Outtet Stors,ina Name 8raderfton l0U t3th Aveoue Easi F� O.ddress . Ciry Staze , " Interest in Property: Lease6oid Name oi Fae Shnpte Tateholder: Zeph�rtills Plaza LLC 5Z36 Commerciai Way Ste F�E�erem trom ovmerustea abm+e) Spring Hip , p�, Address Mclnt�rre Etwell 8�Strammer GC,Ina �ry S�°�e N a 4. Comrador.____ C 1S45�a`rRber Raad Sarasota FL ��� N Conuadors7elephoneNo.: �1-3�-�d� �ty Slate ��o 5. Surery: N/A r��� Name {i/ r ��T Address City Stete lM..�o fvnount M Bond:S 7elephone No.: �M 6. Lender: N/A �� � Name ,� o ��� �►Y State �~� m Lendets Telepbone No.: � O 7. Pers4ns wilhin the State pf Florida designated by the rnvner upon whom not3ces or other douunenls may be served as provided by �m Sedirm 713.73(1y(a)(�,Florida Statute&: �N 3 v Name - � 0 r r Address Cih' Stete Ln Tetephone tdumber ot Deslgnated Pet&on:. 8. In addiqon lo himself,the owner designates o{� to recetve a capy of the�efs Notice as provided in Section 713.i3(t}(b�,Flaida Statutes. Telephone Number of Person w Entiry pesignaled by Oxmer. 9. E�iradon date o!Notice of Cammencement{tMe e�iraUon daie may not be before the canple8on o!wnsUvdton and finai payment to the canvactor,but wlil be ane year trom the Qate ai recar�irtg unless s diHereni date is spedfie�: WARNING TO OWNER: ANY PAYMENTS MA6H BY THE OWNER AF7ER THH EXP�RA710N OF THE NOTICE OF CdMMENCEMENT ARE CONSIDERED IMPRqPER PAYMENTS UNDER CHAPTER?13, PART 1, SECTIQN 743.13. FLORIDA STA7UTES, AND GAN RESUl.T IN YOUR AAYIIYG T1MCE FOR IMPRpVEMENTS TO Y011R PRQPERN. A NOTiCE O�COMMENCEtatENT Mi7ST BE RECOROED ANO FOSTED ON THE JOS SFTE BEFdRE THE fIRST tNSPECTIpN.IF YOU INTEFlp TO OSTAthI fINANCING.CONSUL7 WITH YOUR LEHDER OR AN ATiORNEY BEFORE COMMENCING WORK OR RECORDINO YOUR NOTICE OF COMMENCEMENT, Under penalty of petjury,l deda2 tAat 1 have read the fosegoing no6ce of castmentement and that ihe tsds SWted therein are We to the bat of my k�pwfedge and De6et. ���� ��4��5�� :���� ma,t�ts., evos ;�� SfgnaWre of Owner or E.essee,or Ownets or Lessee's Authozized ' = NotaryPubiic-SfateatFkrida p{t /p7�Q� erJMana er "•". o "`��• MCCmmsEacniresAu36.2021 , •_•• �er 9 : � 'u' 'cI� o� v�' C�n ' ••� .. • Y P 9 U��0� „�.cP��.•• SIg1f6t0[yf5 EJOf[iC6 �} The faregoing inshument wa5 arJmovAadged be ore me is�day o►��j���f����Ol,�by �� ��[Z 1�� as�,�� C�Q���:�'/�M. (typI�of aG�/hority,e.g.,officer,trustee,aUomey in tactj for {rsame p'�[t��npqF{�EfQfwhmninsWmentvrasexecuted}. Personptty Kno Qg Produced IdenGfication❑ Notary Signeture i� ��U�y Type a!IdenUficatton Producei3 Name{Printj � �� 1JG YtJJ wpdatalbcsfn oticecammencement�d153046 . , ��' OR BK g643 P� 71� -- 2 of 2 Legal Description 03-26-21-0010-12800-0000 Assessed in Section 03, Township 26 South, Range 21 East of Pasco County, Florida �EPHYRHILLS COLONY CO LANDS PB 1 PG 55 THAT PART OF TRACTS 113 & 128 LYING EAST OF US 301 DESC AS C�M AT SE COR OF SECT- I�N 3 TH NOODG 25' 50"W 23.95FT TO NLY RIGHT-OF-WAY LINE OF NORTH AVE PER 4R 1227 PG 653 FOR POB TH CONT NOODG 25' 50"W 473.35 FT TO WLY R/W LINE OF FORT KING RD TH N25DG 39' 30"W137.85 FT TH WEST (N90DG 00' 00"VI!) 177.53 FT TH S23DG 19' 56"E 135.82 FT TH S65DG 25' 48"W 242.20 FT TO PT ON CURVE CONCAVE TO NE OF NELY R1W LINEOF US 301 TH ALG ARC OF CURVE RAD 1031 .21 FT CHDBRG � DIST S15DG 54' 11"E 45.00 FT TH N65DG 25' 48"E 144.52 FT TH S23DG 38' 48"E 164.62 FT THS65DG 25' 48"W 150.00 FT T4 PT ON CURVE C�NCAVE T4 NE OF SAID ELY R/W LINE US 301 TH ALG ARC OF CV RAD 1031 .21 FT CHDBRG & D1ST S31 DG 40' 25"E 192.05 FTTO NLY R/W NORTH AVE TH S87DG �0' 18"E 233.28 FT TO POB AKA PARCEL 1 4R 3707 PG 186 o�U I.L0111Ufl . � �"`e'",;"?�-,�" •,'�,�._,_ �: . ! City of Zephyrhills , BUILDING PLAN REVIEW COMMENTS ' � I Contractor/Homeowner: �� Date Received: �Z— ?7—(� site: a�d �P�'► ll �/ lf-G� a Permit Type: ��� S �/2 � `Q� ,.5 Approved w/no comments:LI Approved w/the below comments: ❑ Denied w/the below comments: ❑ ��P2 cv� This comment sheet shall be kept with the permit and/or plans. �'� � i• �-�� �� Gene Brown—Fire Safety Officer Date> Contractor and/or Homeowner (Required when comments are present) , � �Pinellas L Sarasota 13075 US Hwy 19 N 1595 Barber Road � �� Clearwater, Florida 33764 Sarasota, Florida 34240 'p e r Phone: (727) 581-9339 Phone: (941) 377-2100 � Fire Protection F a x: (7 2 7) 5 8 1-8 3 32 Fax: (941) 377-2001 Fire Protection � Material Submittal Sheets B L'S OUTLET 60 o GALL BLVD. 3 � ZEPHYRHILLS, FL 33542 JOb# 10-10-00g0g December 20, 201� � Listing and Approval � Information Design • Install • Inspect • Service Lic.#:EF-0001219•Lic.#:57668600012001 •Lic.#:392845000622001 •Lic.#:71286800011990•Lic.#:45152300011999 � - 1-800-327-7604 • WWW.PIPERFIRE.COM i � . �y�� Worldwide Fire Protection Contacts W�'�co-fire.com Products Series TY-L — 5.6 and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage corrosive environment. The effects of �T�:---.�:. ��. General ambient temperature,concentration of �"' � � � chemicals, and gas/chemical velocity, `� � -�`�� �' �� ��=:-. Descr►pt�on should be considered, as a minimum, � along with the corrosive nature of the The TYCO Series TY-L, 5.6 and ,'��' � --��=��^•, ;�� 8.0 K-factor, Upright, Pendent, chemical to which the sprinklers will be - and Recessed Pendent Sprinklers exposed. _ �,,� described in this data sheet are stan- An intermediate level version of the - � �r-�,�-,_��� dard response, standard coverage, Series TY L Pendent Sprinkler can be �:r �=� solder type spray sprinklers designed obtained by utilizing the Series TY-L - ': ;,_� for use in light, ordinary, and extra Pendent Sprinkler in combination with ���.. hazard,commercial occupancies such the Model S Shield. -- V `:=r ,'��'`" as banks, hotels, shopping malls,fac- _ �-�--:;�;�� tories,refineries,chemical plants,etc. ,� �""'m The recessed version of the Series The TYCO Series TY-L, 5.6 and 8.0 - TY-L Pendent Sprinkler, where appli- K-factor, Upright and Pendent Sprin- i!"�' „�;. ". '\, cable, is intended for use in areas with k/ers described herein must be � �� � - - � a finished ceiling. It uses a two-piece installed and maintained in compliance .-' f`� `� . :��`:;�,, Style 20(1/2 inch NPT)or Style 30(3/4 with this document,as well as with the - ��� ^. inch NP� Recessed Escutcheon.The applicable sfandards of the National � � y P-'`.�' Recessed Escutcheon provides 1/4 in. Fire Protection Association,in addition -� ,� ;i;�';.' (6,4 mm)of recessed adjustment or up to the standards of any ofher authori- ��' � to 1/2 in.(12,7 mm)of total adjustment ties having jurisdiction.Failure to do so �, � from the flush pendent position. The may impair the pertormance of these j adjustment provided by the Recessed devices. Escutcheon reduces the accuracy to The owner is responsible for main- �_�;; which the fixed pipe drops to the sprin- � � � � klers must be cut. taining their fire protection system and devices in proper operating con- Corrosion resistant coatings, where dition. Contact the installing contrac- applicable,are utilized to extend the life for or product manufacturer with any of copper alloy sprinklers beyond that questions. which would otherwise be obtained ' when exposed to corrosive atmo- Sprinkfer spheres. Although corrosion resistant coated sprinklers have passed the ,�entification , standard corrosion tests of the appli- cable approval agencies,the.testing is ��mber (SIIV) , not representative of all possible cor- rosive atmospheres. Consequently, TY3111. .. . . .0 ri ht 5.6K, 1/2" NPT it is recommended that the end user TY3211 . . . .Pendent 5.6K 1/2" NPT be consulted with respect to the suit- TY4111. .. . . Upright 8.OK,3/4" NPT ability of these coatings for any given TY4211. . . . .Pendent 8.OK,3/4"NPT TY4811 . . . . .Upright 8.OK,1/2"NPT IMPORTANT TY4911 . .. .Pendent 8.OK,1/2"NPT Always refer to Technical Data TY3111 is a re-designation for S1800 Sheet TFP700 for the `7NSTALLER and G3111. WARNING" that provides cautions TY3211 is a re-designation for S1801 with respect to handling and instal- and G3112. lation ofsprinklersystems and com- TY4111 is a.re-designation for S1810 ponents. Improper handling and and G3101. installation can permanently damage TY4211 is a re-designation for S1811 a sprinkler system or its compo- and G3102. nents and cause the sprinklei to fail TY4811 is a re-designation for S1805. to operate in a fire situation or cause TY4911 is a re-designation for S1806. it to operate prematurely. Page 1 of 6 NOVEMBER 2015 TFP110 � ; TFP11� ` Page2of6 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Ejection 5 - Strut is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Sealing Spring 6 - Hook Deflector. special request. PLATE SEATING Button 4 - Fusible 7 - Deflector* SURFACE Element � WRENCH 2-5/8" AREA � , 2 (66,7 mm) ' 2-5/8" 7/16" (66,7 mm) 3 /4 (11,1 mm) NOMINAL 2" STYLE 20 5 MAKE-IN � (50,8 mm) RECESSED � ESCUTCHEON ;, 6 \ . . 1/2"NPT** WRENCH 2-7/8"(73,0 mm)DIA. 7* FLANGES UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION - FIGURE 1 STANDARD RESPONSE SERIES TY-L UPRIGHT(TY311i)AND PENDENT(TY3271)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Ejection 5 - Strut is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Sealing Spring 6 - Hook Deflector. special request. PLATE SEATING Button 4 - Fusible 7 - Deflector* SURFACE Element 1 WRENCH ' � 2-11/16" AREA � . 2 (68,3 mm) 1/2" 2-11/16" 4 (12,7 mm) (68,3 mm) 3 � NOMINAL MAKE-IN , (50,8'mm) STYLE 30 5 � RECESSED ESCUTCHEON 6 \ :. 3/4"NPT** WRENCH 2-7/8"(73,0 mm)DIA. 7* FLANGES UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION F/GURE 2 STANDARD RESPONSE SERIES TY-L UPRIGHT(TY4111J AND PENDENT(TY4211)SPRINKLERS 8.0 K-FACTOR,3/4/NCH NPT , , ' TFP110 Page3of6 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Ejection 5 - Strut is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Sealing Spring 6 - Hook Deflector. special request. , PLATE SEATING Button 4 - Fusible 7 - Deflector* SURFACE Element 1 WRENCH 2-5/8" AREA � 2 (66,7 mm) 7/16" 2-5/8" (11,1 mm) (66,7 mm) 3 _4 NOMINAL 2�� STYLE 20 5 MAKE-IN 1 (50,8 mm) RECESSED � ESCUTCHEON . 6 \ � . . 1/2"NPT** WRENCH 2-7/8"(73,0 mm)DIA. 7* FLANGES UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION FIGURE 3 STANDARD RESPONSE SERIES TY-L UPRIGHT(TY481 i)AND PENDENT(TY4911)SPR/NKLERS 8.0 K-FACTOR, i/2/NCH NPT Technical DesJ n Series TY-L Pendent and Upright g Sprinkler Installation Data Criferia The Series TY-L Pendent and Upright Sprinklers must be installed in accor- Approvals The TYCO Series TY-L, 5.6 and dance with this section. UL and C-UL Listed.FM,and LPCB 8.0 K-factor, Upright, Pendent, and Pendent sprinklers are to be instailed Approved.(Refer to Table A for complete Recessed Pendent Sprinklers are in the pendent position, and upright approval information including corrosion intended for fire protection systems sprinklers are to be installed in the resistant status.) designed in accordance with the stan- upright position. Maximum Working Pressure dard installation rules recognized by the Step 1. With pipe thread sealant 175 psi(12,1 bar) applicable Listing or Approvai agency applied to the pipe threads, hand Dischar e Coefficient �e.g.,UL Listing is based on the require- tighten the sprinkler into the sprinkler 9 ments of NFPA 13, and FM Approval fittin K=5.6 GPM/psi'i2(80,6 LPM/barYZ) is based on the requirements of FM's 9' K=B.o GPM/psi'�=(115,2 LPM/bar'�=) Loss Prevention Data Sheets). Only Step 2. Tighten the sprinkler into the Temperature Ratings the Style 20 or 30 Recessed Escutch- sprinkler fitting using only the W Type Refer to Table A eon, as applicable, are to be used for 9 Sprinkler Wrench (Ref. Figure 7), ' recessed pendent installations. except that an 8 or 10 inch adjust- Finishes able Crescent wrench is to be used Sprinkler:Refer to Table A Recessed ' for wax Coated sprinklers. With refer- Escutcheon:White Coated,Chrome ��s����a���� ence to Figures 1,2,and 3,the W-Type Plated,or Brass Plated The TYCO Series TY-L, 5.6 and 9 Sprinkler Wrench is to be applied to Physical Characteristics $.0 K-factor, Upright, Pendent, and the wrench area, or as applicable, the ' Frame ... . . . . . .. Brass Recessed Pendent Sprinklers must adjustable Crescent wrench is to be Sealing Button Bronze w/TEFLON be installed in accordance with this applied to the wrenching flanges. Ejection Spring . Stainless Steel section: When installing wax coated sprinklers Strut ..................... MONEL Hook..... .. .... Bronze/MONEL A leak tight 1/2 inch NPT sprinkler joint with the adjustable Crescent wrench, Deflector ... . .. . ...Bronze should be obtained with a torque of 7 additional care needs to be exercised Fusible Element....... ....Solder,Copper, to 14 ft.-Ibs. (9,5 to 19,0 Nm). A leak to prevent damage to the wax coating � stain�ess stee� tight 3/4 inch NPT sprinkler joint should on the sprinkler wrench flats or frame � eration be obtained with a torque of 10 to 20 arms and, consequently, exposure of � ft.-Ibs. (13,4 to 26,8 Nm). Higher levels bare metal to the corrosive environ- A copper tube sealed by two stainless of torque may distort the sprinkler inlet ment.The jaws of the wrench should be steel balls holds a fusible alloy. When and cause leakage or impairment of the opened sufficiently wide to pass over the rated temperature is reached, the sprinkler. the wrench flats without damaging the alloy melts,the balls are forced toward Do not attempt to make-up for insuf- Wax coating. Before wrench tightening each other releasing the tension mech- ficient adjustment in the escutcheon the sprinkler,the jaws of the wrench are anism,allowing the sprinkler to operate. plate b under- or over-ti htenin the to be adjusted to just contact the sprin- Y 9 g kler wrench flats. After wrench tight- sprinkler. Readjust the position of the ening the sprinkler, loosen the wrench ' sprinkler fitting to suit. jaws before removing the wrench. TFP11�0 � Page 4 of 6 Frame Sprinkler Finish K Type Ra ng Color Natural Chrome Lead Wax Wax Over Code Brass Plated Coated Coated Lead Coated Pendent(TY3211) 165°F(74°C) Unpainted 1 2 3 and 212°F(100°C) White 1,2,3,5 5.6 Upright(TY3111) 1/2" 280°F(138°C) Blue 1,2 4 N/A NPT Recessed Pendent 165°F(74°C) Unpainted 1,2,3,5 (TY3211 w/Style 20) 212°F(100°C) White 1,2,3,5 N/A 165°F(74°C) Unpainted 1,2,3 Pendent(TY4211) 212°F(100°C) White 1,2,3 280°F(138°C) Blue 1,2 4 N/A 8.0 165°F(74°C) Unpainted 3/4" 1,2,3 NPT Upright(TY4111) 212°F(100°C) White 1,2,3,5 280°F(138°C) Blue 1,2 4 N/A Recessed Pendent 165°F(74°C) Unpainted (TY4211 w/Style 30) 1�2�5 N/A 212°F(100°C) White Pendent(TY4911) '165°F(74°C) Unpainted 1,2,3 and 212°F(100°C) White 1,2,3,5 8�� Upright(TY4811) I 1/2" 280°F(138°C) Blue 1,2 N/A N PT Recessed Pendent '165°F(74°C) Unpainted (TY4911 w/Style 20) 1�2 N/A 212°F(100°C) White OTES: UL Listed . C-UL Listed . FM Approved . FM Approved for maximum 150°F(68°C)ambient temperatures . LPCB Approved(LPCB Ref.No.094a/03) N/A:NotAvailable TABLE A LABORATORY L/STINGS AND APPROVALS After installation, the sprinkler color coded wax is to be used, and Step C. After the ceiling has been wrench flats and frame arms must retouching of wrench flats and frame installed or the finish coat has been be inspected and the wax coating arms is only permitted at the time applied, slide on the Style 20 or 30 retouched (repaired) whenever the of initial sprinkler installation. With Closure over the Series TY-L Sprin- coating has been damaged and bare tf►e steel rod heated as previously kler and push the Closure over the metal is exposed.The wax coating on described, touch the rod to the area Mounting Plate until its flange comes the wrench flats can be retouched by requiring additional wax with the rod in contact with the ceiling. gently applying a heated 1/8 in. diam- angled downward, and then touch the eter steel rod to the areas of wax that wax stick to the rod approximately one- � have been damaged, to smooth it half inch away from the area requiring back over areas where bare metal is retouching. The wax will melt and run exposed. down onto the sprinkler. Series TY-L Recessed Pendent � Sprinklers Installation Only retouching of the wax coating The Series TY-L Recessed Pendent applied to the wrench flats and frame Sprinklers must be installed in accor- arms is permitted, and the retouching dance with this section. is to be performed only at the time of Step A. After installing the Style 20 the initial sprinkler installation. or 30 Mounting Plate, as applicable, The stee/rod should be heated only over the sprinkler threads and with to the point at which it can begin to pipe thread sealant applied to the pipe melt the wax,and appropriate precau- threads,hand tighten the sprinkler into tions need to be taken, when handling the sprinkler fitting. the heated rod, in order to prevent the Step B. Tighten the sprinkler into the installer from being burned. sprinkler fitting using only the W Type If attempts to retouch the wax coating 10 Recessed Sprinkler Wrench (Ref. with complete coverage are unsuc- Figure 8).With reference to Figure 1,2, cessful,additional wax can be ordered or 3,the W Type 10 Recessed Sprinkler in the form of a wax stick (the end of Wrench is to be applied to the sprinkler ' which is color coded).Only the correct wrenching flanges. � . ' TFP110 Page 5 of 6 7/16t1/8" 2-7/8" DIA. 1/2"(12,7 mm) (11,1±3,2 mm) (73,0 mm) �/4"(6,4 mm) FACE OF 2-1/4" DIA. MOUNTING WRENCH SPRINKLER (57,2 mm) � PLATE RECESS � FITTING I 1/8" = r (3,2 mm) � \ � �� _1 ��— - - MOUNTING FIGURE 7 i SURFACE 1-3/4"(44,5 mm) W-TYPE 9 SPR/NKLER 1-1/2"(38,1 mm) WRENCH CLOSURE TY-L WRENCH F/GURE 4 RECESS\ SERIES TY-L(TY3211)RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 7/16±1/8" 2-7/8" DIA. 1/2"(12,7 mm) (11,1±3,2 mm) (73,0 mm) 1/4"(6,4 mm) F/GURE 8 FACE OF 2-1/4" DIA. MOUNTING W-TYPE i0 RECESSED SPRINKLER (57,2 mm) � PLATE SPRINKLER WRENCH FITTING / -� I 1/8" _ ; �3,2 mm) Care ar�d � � -� � Maintenance MOUNTING The TYCO Series TY-L, 5.6 and SURFACE 1-3/4"(44,5 mm) $•0 K-factor, Upright, Pendent, and 1-1/2"(38,1 mm) Recessed Pendent Sprinklers must be maintained and serviced in accordance CLOSURE TY-L with this section. FIGURE 5 Before closing a fire protection system SERIES TY-L(TY4217)RECESSED PENDENT SPRINKLER ASSEMBLY main control valve for maintenance WITH TWO-PIECE 1/21NCH TOTAL ADJUSTMENT work on the fire protection system that STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR,3/4 INCH NPT it controls,permission to shut down the affected fire protection system must be obtained from the proper authorities 7/16t1/8" 2-7/s" DIA. 1/2"(12,7 mm) and all personnel who may be affected (11,1t3,2 mm) (73,o mm) 1/4"(6,4 mm) by this action must be notified. FACE OF 2-1/4" DIA. .�l MOUNTING Absence of an escutcheon, which is SPRINKLER (57,2 mm) I PLATE used to cover a clearance Hole, may FITTING delay the time to sprinkler operation in � I 1/s" a fire situation. (3,2 mm) Sprinklers that are found to be leaking ' !- _� � or exhibiting visible signs of corrosion � must be replaced. MOUNTING Automatic sprinklers must never be painted, plated, coated or otherwise � SURFACE 1-3/4"(44,5 mm) altered after leaving the factory. Modi- 1-1/2"(38,1 mm) fied or over-heated sprinklers must be replaced. Care must be exercised to C�OSURE TY-L avoid damage to the sprinklers-before, FIGURE 6 during,and after installation.Sprinklers � SERIES TY-L(TY4911)RECESSED PEIVDENT SPRINKLER ASSEMBLY damaged by dropping,striking,wrench WITH TWO-PIECE 1/2INCH TOTAL ADJUSTMENT _ twist/slippage, or the like, must be � STYLE 20 RECESSED ESCUTCHEON 8.0 K-FACTOR, i/2 INCH NPT replaced. Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprin- klers, after the installation has been TFPii•0 ' Page6of6 P/N 53 - XXX - X - XXX SIN SPRINKLER TEMPERATURE FINISH RATING 111 5.6K UPRIGHT(1/2"NPT) TY3111 1 NATURAL BRASS 165 165°F(74°C) 112 5.6K PENDENT(1/2"NPT) TY3211 6 WAX COATED 212 2�2�F(100°C) 165 F TO 280 F ONLY 101 8.OK UPRIGHT(3/4"NPT) TY4111 7 LEAD COATED 280 280°F(138°C) 102 8.OK PENDENT(3/4"NPT) TY4211 g WAX OVER LEAD 165 F TO 212°F ONLY 106 8.OK UPRIGHT(1/2"NPT) TY4811 9 CHROME PLATED � 107 S.OK PENDENT(1/2"NPT) TY4911 TABLE B SERIES TY-L PENDENT AND UPR/GHT SPRINKLERS PART NUMBER SELECTION completed,to verify the integrity of the ' Sprinkler Wrench corrosion resistant coating.Thereafter, Order►n� Specify: W Type 9 Sprinkler Wrench, annual inspections per NFPA 25 should p r o c e d u r e P�N 56-000-1-849 suffice; however, instead of inspecting Specify: W Type 10 Sprinkler Wrench, from the floor level,a random sampling Contact your local distributor for avail- P/N 56-000-1-948 ' of close-up visual inspections should ability.When placing an order,indicate be made,so as to better determine the the full product name and Part Number Wax Sticks(for retouching wrench � exact sprinkler condition and the long �P�N� damaged wax coating) term integrity of the corrosion resistant Specify: Series TY-L Sprinklers, coating, as it may be affected by the Sprinkler Assemblies with NPT (specify color), color coded Wax Stick corrosive conditions present. Thread Connections for retouching, (specify) temperature The owner is responsible for the Specify: Series TY-L (specify SIN), rated, P/N(specify): inspection,testing,and maintenance of �specify K-factor), (specify Upright, Red for 165°F��a°C) . .. . P/N 56-065-1-155 their fire protection system and devtces Pendent,or Recessed Pendent)Sprin- B11e for 2�2°F�1oo°c) in compliance with this document, as kler, Standard Response, Standard and 280°F(138°C).. .... .P/N 56-065-1-286 well as with the applicable standards Coverage,(specify)temperature rating, NOTES: of the National Fire Protection Asso- �specify)finish or coating,P/N(specify ciation e. NFPA 25 , in addition to from Table B) Each wax stick is suitable for retouch- � 9•. ) ing up to twenty-five sprinklers. the standards of any other authorities Recessed Escutcheon having jurisdiction.Contact the install- Specify: Style (specify) Recessed The wax used for 280°F(138°C)sprin- ing contractor or product manufacturer Escutcheon with (specify finish), P/N klers is the same as for 212°F(100°C) with any questions. (specify): sprinklers, and, therefore, the 280°F It is recommended that automatic 1i2"(�5 mm) (138°C)sprinkler is limited to the same s rinkler s stems be ins ected,tested, maximum ceiling temperature as the p y p Bral s Plated. . . . . . .P/N 56-705-2-010 2i2�F (100°C) sprinkler (i.e., 150'F and maintained by a qualified Inspec- ��2^��5 mm) (65°C)). tion Service in accordance with local styie 20 requirements and/or national codes. signai wn�te�Rn�soos).....PiN ssao5-a-oio 1/2"(15 mm) L,m�i.e�,/ Style 20 d �� Chrome Plated......... ..P/N 56-705-9-010 Warra�ty 3/4"(20 mm) Style 30 Brass Plated.. . . . . P/N 56-705-2-011 For warranty terms and conditions,visit sia��(20 mm) www.tyco-fire.com. styie so Signal White(RAL9003).....P/N 56-705-4-011 3/4"(20 mm) Style 30 Chrome Plated.... . . .P/N 56-705-9-011 GLOBAL HEADQUARTERS�1400 Pennbrook Parkway,Lansdale,PA 19446�Telephone+1-215-362-0700 Copyright O 2015 Tyco Fire Products,LP. All rights reserved. ���.o MONEL is trademark of Special Metals Corporation. Fire Protection Products TEFLON is trademark of The DuPont Corporation ,I I s � ■ � I I� �1C1�� �1�� �1�7���5 _ � �__� (Co ' _ � Black & Galvanized, Std. Sch. 40, XH Sch. 80 � ' � ; � , � � - „'-• `�' w,SGv.:w�..v.,.'�b'1tj, - ' '_"�? .-- - "....�.,1��•".^��.$',�,.,,` � _i �, <".�'�" .- "��: .- 's��.„ � L._._.� - •'� ���;a�m.:�. , _ _ .�k.:-;..� ---�.��,�. _ �„ -:.�.�.. -----w�;���� `��,� ,.` J�`Y���;"` i.,\1�` .,��v`,��,`����.`ii�\�1: � �°`.1��'� " 2'�t'**�'�" `�\�� " a�' f ' \ ��F� ..1�;� ��.�4�\e;�5 ��°.\ t. �� .:.'r' i� '~c�1`4 ` + 4,, `l•�''' `� '' ' � ` y�� � `���� ''�:}'��U.F��! `e .L,�'�y�µ�' � �v `�����r^ ,� . .. �'�.�� '{`I� _ , :i � 4 `'Y �'s�',�.� tf`�1 � ��t . .. �. x � l )I��+ �� �i�: �. �( i'. :i, �°`� _ _ � �� 1 ,� - . ,, .� � r ' M�� , . : .,� . ..�.! i� - - � �_.�...�'"= --.. -�a r-- -, FIG. 339: FIG. 338: F6G.343: FIG. 342: ��, i Standard Extra Heavy Standard Extra Heavy i u,g Black Schedule 40 Black Schedule 80 Galv.Schedule 40 Galv.Schedule 80 �E� � � I � Material OUTSIDE DIAMETER - ASTM A53 Standard Specification for Pipe Steel,Black, TOLERANCES _ = Galvanized,Hot-Dipped,Zinc Coated,Welded. PiPE sizE To�. vs--,vz- svsa - - 2"•8" $1%OF NOMINAL O.D. Rpplicable specification --- � ASTM A733 � `� � (Refer to the chart below for specific pipe dimensions.) INSIDE IN� DIAMETER I�xs t�lote:Minimum wall thickness at any point to be not � �'� � ---- -�. P LL� more than+/-10/nominal wall thickness specified for f �. that size pipe. L---i Nipples over ` • LENGTH t 1/76" 12' long have a � ' Standard and Extra Heavy right and Ieft nipples available lengthtolerance � � ; In�/e—4"d'lameter and 4"and 6'��engths. Standard NPT Tapered Pipe Threads as of+/-%e'. l� ; per APISI B 1.20.1 Specification. a ; � i , • • , . , L__� i i � � • � � � �� ; i ` inin _ in _ ._.. - -- - — ---- --- -- ---- - -- _ - - � - - --- - � � , �/a 0.405 3/a 1�/z 2 2�/2 3 3Yz 4 4�/z 5 5�/z 6 7 8 9 10 11 12 �'� E '/4 0.540 �/8 1 Yz 2 2�/z 3� 3�/z 4 4�/z 5 5Yz 6 7 8 , 9 10 ]1 12 f� : 3/8 0.675 1 1�/z 2 2�h 3 3'/z 4 4�h 5 5�/2 6 7 8 9 10 11 12 ; � ! I �/z 0.840 1 Ye 1�/x 2 2�/z 3 3�/z 4 4�7z 5 5'/x 6 7 8 9 10 11 12 i �, f I� 3/ 1.050 I 3�8 1�/z 2 2�/� 3 3�/z 4 4�/z 5 5�/2 6 7 8 9 10 11 12 ;o ; I 1 1.315 1'/z 2 2Y2 3 3'h 4 4�/z 5 5'/z 6 7 8 � 9 10 11 12 'L � I 1'/a 1.660 15/e 2 2Yz 3 3Yz 4 4�/z 5 5�/s 6 7 8 9 10 11 12 �m j � 1'/x 1.9 0 0 13/a 2 2'/z 3 3'/z 4 4'/z 5 5�/z 6 7 8 9 1 0 1 1 1 2 �� � t.-- -' 2 2.375 2 2�h 3 3�/z 4 4�/z 5 5Yz 6 7 8 9 10 11 12 ;-�-- 2'/z 2.875 2'/z 3 3Yz 4 4�/z 5 5Y2 6 7 8 9 10 11 12 i� ' ie 3 3.500 Z5�8 3 3�/z 4 4�/2 5 5�/z 6 7 8 9 10 11 12 j� 4 4.500 2�/a 4 4�/2 5 5'/z 6 7 8 9 10 11 12 �� , 5 5.563 3 4�/z 5 5Y2 6 7 8 � 9 10 11 12 r� ' 6 6.625 3'/a 4Yz 5 5'/z 6 7 8 9 10 11 12 � -- � Noie:Otherlengths available. 8"Pipe Size available as POA-contact yourMvil Representative for details. ' Z /�MOIL . �� , �,�Tea�Ar,o�a� PF-11.10 �� ,. �. ' • � I • • � ' FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer Bull Moose Tube's Sch. 10 and Sch. 40 pipes are of quality pipe products. Our Schedule 10 and made to ASTM A135 and ASTM A795. These Schedule 40 are FM Approved and UL Listed (for U.S. products are typically supplied with our protective and Canada), even though these products do not coating but can be supplied without the coating so � require separate approvals and listings. Bull Moose they can be hot-dip galvanized to meet FM Tube made the decision to have them approved and requirements for use in dry systems in accordance listed for your peace of mind. Our Sch. 10 and Sch. 40 with the zinc coating specifications of ASTM A795 or have been through the same rigorous testing as our ASTM A53. All Schedule 10 and Schedule 40 pipe other fine pipe products. has a pressure rating of 300 PSI. Schedule�10 Pipe . � o- . o � . � � o . -� - , . . . �' _ ___.____ ..__ .. .r--._ __. ___..___'—T__ _'_." ' __ _' ��._'�____.___ .____.•r_ `_" _ . '_ __ ' __�____—_ __ _'_"____' ___ � ��_-_�=--- --_:.-...=-=---=---a�-�._:=�=_::.1„315..,.,__-__: �--__-_-_�- 1_097-_;:M_---;�----_ -1.41__I_bs/ft___ .__.,�. -- 9� -�= --- ' _ = ,�- ---. ---_ _ --.- ---_ -=—___= �_.--__--; r - � 1 1/4 ` ,,___ 1.660 ,� 1.442 �! 1.81 Ibs/ft '; , ( _ __- ---� - --_-__.---- , _-- - ---____.--- - 61 - . -..._. v_. _ '"' ' ""' ` ._..,__ .....�_-_--.'"_.... .. �'L_ ___"_' _ '__-_.__ _ ' _ _ ' _'_' _' _'_' '_ _"" _ "' ' ..` _ __. ..'_' ' _' �� ' _ _ ' __'_` _"' ""' ... , ::....=_..f_,� . _�... .. _ ^_ _ _"""" " r �--��- --- --=--_---___�=-.�::.LL--_-.-_=_:.1�_900_n� -=-- -_-;�=--=--=_ 1;682==-==-�.._�t_---=.- -2.09=1bs/ft_--�_--_.1�a_=__._-_.=._.61_:�_---__--_-' �-? =_-._._.-:: _=_��-- =.._-:- _---==--;t. _-_ _ :2.375._,.. - ---- ;;._______._. 2.157 _- -----��- _ _ 2.64 Ibs/ft i 37 - - _ - -�-�_.,_�..___,.=--==--- �__,_..-------=-. - -=�_ __----;�-----_-.---_ =�__=�.____ -- ;--= -- _=�-_= _._—:=r=.._,.;�-- - - - , 2 1/2__ __ � 2.875 � 2.635. _ _ ; _ 3.53 Ibs/ft____ �� 30__ _ _ �_ ="_'_-___ "' '_' :�_-_."'_.:'.�_._.._._ :'_�.-_, '�y.'__- _'-_'_"_=r.'.:__"._-._"._' ""—_.__�.='""� _'_ _ _ _ "4' _ ' "'_ __.. ' ' ., - ..,_r..__ '—__'____' "'_'r_'_____ '_..-_"""_ - _'_'. 3 ____v._ �' _ 3.500 . _ ;I .3.260 ,_------_ f;_ _.___4.34_Ibs/ft _ a --== =-__:----_ ---�--- �-_, _--= -__==_=__== .._____.,_ ._ __ 19 ---- ,==-- - ------ �r - - - --- ___ ::. - =-== - =-_ - - ---- - - - - -- -- -- __ - ����----- - ----- __ --._.�..�_- - ----._�:_...-- --- 4.500.-- -__.�_�_ _._ ._.._4.260._ __.. ..__ .:� ____5.62Ibs/ft- -�- ---- -�-9- -- --_-., G 4=.-__..__ _ _ . Schedule 40 Pipe - . �!ii- _ - yi - i, I,rpy�c`,�� -� aS",u��,;rm .sn..��eo� .; -- � Y..'_. y _ .e ■ 'l��".,'�"'�,^:,� --_- ra �W �o �O .OiY� � _w .�y�' 3;' '-��`,�� 'a i -. -. � - .. - _ . _ ... - . .� ".»�". " '" .,��=�:_ .�.. ,�oF.� - ,uf� " �. ,...... oll��y - ,.�.. ,�.�-��� °�. �,���`_ L;�" - - �,.....< m ..».., ...,..,.. --. ..- - _��.. _. _ _- � - - - . ..-- - . __- .� ... mn, �_.,. . .. ., ..�.�.�,. ;� -=.. . - - - - ., - - .. ._ ..- , __ _ - ; - - -- - - - - , �-=�_�:__--.:�:.�.�.-�_-.__�-_.�-._:_--��-.�4::-W.-.-_-=_�-31_5--:�_----_-:�-_----_= -1,049-.__.._-�:_-'==--=1,.68Ibs/ft.---_�-:�;�--- 70 � . - - -.a . - ,, - - ---- ,r __ ..._____��—_--.._.,_ � - -- - � ..� _. . r._ _ - _ __- ;__1 1/4 '�-.---_-.- -=1_660 _____- _�__- _. --, 1.380_ -_ = -•, ___ 2,27 Ibs/ft -- ='---- - 51 -- - - -._ - -- �- -- - : --- ,. - -- --- ---_----- - - -- = � 1 1/2__ __ _ . . ` _1.900_ 1.61_0_ _ � 2.72 Ibslft � 44 � ,-.. . - - - - - -- - - - ---- - -- - ---- -- - - -- - - � - - --_- _---_- -_: _ - -- --_,__ __---- - .� --- - _ .._ - - - ; ! 2 : 2.375 ;; - . 2.067 _ 3.66 Ibs/ft ___ ._;;_ _. _ 30 ;_ _�._:.-,__� ., .._ ::-_--_-_--;._.__, � _,_._____.__._� - :- ,:--_.---�.-- - - --- - - _ - ___ -- _ _ . -- ---__-.- _ _ ..,_.. __ �_2 1/2 � 2.875 � 2.468 � 5,80Ibs/ft� - :, - - - - --- - --- - - •----- =-- - - - - - -- - --= . - - ---- - - - -- --_-- - 30 , _ - =__ --- �-- - - - ` : —`; - --- --- - � = -- -- ' � 3. _ __ __ , _ _ � _ � 3.500 _ - -';= �_ --� -_3.068=-== _= -~ --- 7.58 Ibs/ft _'�- - _. _.�9 � --- - - - -- - ---- -- - . --= =--=- - -=� ~ --_- • ;_4 _ _ � _ __ __ _ �'_ 4.500� :_ _ _ . 4.026 ' 10.80 Ibs/ft ;._ _ 19 PIPE PREPARATION For proper operation,all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket,pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint,scale,dirt,chips,grease,and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly,causing leakage. Also,check the manufacturer's instructions for the specific fitting used. � � 1819 Clarkson Road For additional information, � �. Chestefield,MO 63017 contact your salesperson C .-L uS `�� II BULL MOOSE TUBE COMPANY �800)325-4467 today at(800)325-4467 or ���T� �'"'�-="� FAX:(636)537-2645 (636)537-2600 in the USA, , www.bullmoosetube.com or from Canada F� q CA A O company e-mail:salesn,bullmoosetube.com ��I(800)es2-4666 nPPaovEo All information contained here(n is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurting obligation. 12/09 � � • � � • � � • ' � . • � • � � � � � � FM Approved and Fully Listed Sprinkler Pipe SCFfEDULE 10 SPECIFiCATIONS Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, NOMINAL NOMINAL C-UL and FM Listed. NPs NOM OD NOM ID WALL WEIGHT UL PIECES . _ � ��� -- i; In. � mm In. �r mm 1' In. , mm , Ibs./ft.� kg/m � CRR•`l Llft � Approvals and Specifications -f' -. - --- -�-----�f��__. '. .-_- :[--. _.,_..� __�___._! _.___�:- __. -�__ Both products meet or exceed 1�/a �.eso 42.2 ' 1.442' 36.6 .109 2.�� i.ai 2.69 ' 7.3 ei thefollowingstandards: --a: - - E- - ,r .- __ _ . _ ;, _ _.., _ 1'b ; 1.900 �, 48.3 i 1.682 '; 42J ' .109 ;� 2.77 �' 2.09 ;� 3.11 " 5.8 ;j 61 • ASTM A735,Type E,Grade A(Schedule 10) -'"�'� �� - "- � '' ' - '-� - " - �- '" - " - `"'' 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 ` 4.7 ' 37 • ASTM A795,Type E,Grade A(Schedule 40) -~, - - � •- - � ---- -�� - - - � - -�- 2�/z �; 2.875 i 73.0 ; 2.635 66.9 ' .120 ' 3.05 ' 3.53 �j 5.26 3.5 � 30 • NFPA 13 -' - -- - - -'� . . ,-• - _ _._ , , ,_ , __�; - 3 3.500 88.9 3.260 � 82.8 .120 3.05 4.34 6.46 2.6 � 19 � Manufacturing Protocols -'�"' y�- - "- �--- "�" 'i� ,: � " 4 ` 4.500 :: 714.3 ,� 4.260 ,, 108.2 , -.720 3A5 , 5.62 ,� 8.37 .' 1.6 79 � , Schedule 10 and Schedule 40 are subjected ____� _ ____ ._ _ _ _, t _ ___ .__. _ , . _ ___ � to the toughest possible testing protocols to 5 5.563 147.3 7 5.295 ; 134.5 .134 3.40 ;• 7.78 11.58• 1.5 13 ensure the highest quality and long-lasting ---� . ,� -__ _„ e ._ , � , � , performance. e �; 6.625 ; 168.3 i 6.357 ' 161.5 _734 �! 3_40 ; 9.30 ;; 13.85 ! 1_O 10 8 1 8.625 219.1 8.249 209.5 j .188 4.78 16.96 , 25.26 , 2.1 � 7 Finishes and Coatings ------- ' - � - AII Wheatland black steel fire sprinkler pipe ����ulated using Standard UL CRR/oimu/a,UL Fire Protectlon D/ieetory,Category V/ZY. Up t0 6�� receives a proprietary mill coating to 'The CRR/s a iatlo value used to measure the ablllty of a p/pe to w/thstand conoslon. Threaded Sehedu/e 40 stee/p/pe Is used as the benehmark(value of 1.0). ensure a clean,corrosion-resistant surface that outperforms and outlasts standard lacquer coatings.Thiscoatingallowsthepipetobe SCFlEDl1LE 40 SPECIFICATIOIVS easily painted,without special preparation. Schedule 10 and Schedule 40 can be ordered in NOMINAL NOMINAL black,or with hot-dip galvanizing,to meet NPS NOM OD NOM ID WALL WEIGHT UL PIECES _-i ' . __ ;�_.._____._. � -- -----� FM/UL requirements for dry systems that meet i� in. ' �� mm i� mm o�. '� mm : Ibs./ft.� kg/m.;; cRR• ; uh - - �- the zinc coating specifications of ASTM A795 - --��- - -- -' - � --•--••-� -�- -�'_ ._.�_r.__��_. __ __�'L,�i ___._�:�._ .... . _.___�1 or A53.All Wheatland galvanized material is 1 i.ais 33.4 i.oa9 26.6 .133 3.38 i.es � ' z.so i.00 �o also UL Listed. �� � ' � � �li - 1'h ;j 1.660 i� 42.2 ; 1.380 r .35.1 .140' ,. 3.56 2.27 3.39 7.00 51 � _." ._ �--- --- --_ ,L---�--• ___. _ Product Marking 1'h 1.900 48.3 7.610 40.9 .145 3.68 2.72 4.05 1.00 44 Each length of Wheatland fire sprinkler � �""{ -" - " �, �f" �- 1; -" � , -- 2 �i 2.375 ti 60.3 ' 2.067 ' S2.5 .154 , 3.91 3.66 i 5.45 1.00 : 30 pipe is continuously stenciled to show _.. _ ._�_ _....___ __. __.. ._. ._ _._ ___ _ _.._._ ..__•�_ __ _ _ _ the manufacturer,type of pipe,grade,SIZ@ 'Calcu/ated using Standard UL CRR/ormu/a,UL Flre Piotect/on D/rectory,Category V/ZY. and length.Barcoding is acceptable as a 'The CRR/s a ratlo value used to measuie the abl/ity of a p/pe to wlthstand conoslon. SUppl@�'1211t8ry Id@�tlflCatl011 Il12thOd. Th�eaded Schedule 40 stee/p/pe!s used as the benehmark(value of 1.0). u� C u� FM APPROVED • � � • ! PROJECT: ' CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: ❑ BLACK ❑ HOT-DIP GALVANIZED r z . - `• . •. - . .. . �l1/�1��t'�11Ct Tube i�� � �• •� • • • • • • JMC STEEL GROVP �I I ' ` • e • I I, ,•�;,� ��. �.._� - _ � .� � ;�\� _ �-�� _ •�' - ���_�, �;�-� - _� . . _ �-,,: .�. > v ,�.`t � �; . ,> _ � _ � ,,, . ,. :'t . , � , ,�' � . . z:� _ .. . , .. . "S-� .. -., � . _ :1''L' . ,... #y�,.. .�R'n;r._' rM'� /� .w�._ :ti.r�.,._§ xV) � � / _ - :�_a: � ., . � t �a;F���" �, . � * =��« J - - ,.-Y�r' -� � � � . .,9 �.. �� a✓ � ' � � � � :I S �� _ �. � �� f U ' +F�r iv�� � ; ' II� � � � i I ',, s ��� - � *� � - �zr , �_-, _ �a�• �. I r I � y -......--- �-�-�, :..00'ST � � ;``�" � ,--,°-'a� a� �_ ;`�- 'f�l�.. � , _.""'�..o+�_•-�_ � ' � N tA �� _�`�Vb.�.�ug���T.�. j. ' �`.� `,A i N C + `i". .7����:5r'��''•°�. ,,'1... _� ��' -`����`�.�� � �LLI •y�.r�'. .y. SA::� � iw.-, `a`i`•;� j' a' �� � !� ( .f `,y�. .,y�j�,; ' + ��. ' . �'��''- , .� �t � �.s ��� et <:'� : � � >,) ::,;v g ��j i n�H� �---� .A,' �' p � � �� y� � �1�� � 1 `��. '� �� C � �t"� � e'^` .�t� ' �°�n i �� � 1 � a� Z U, � `�• � a a I i d� � -._ � 5 �� - ''S-i � i � �' i s.,.,:` �"`.�.' 1� ] �r _ '_ ':v..' I J _, � � ) G I 7 - O µy„ C �_ . �a at5 � yi .". " � �Q L�C Y.� 4__�' (_e-_i k Malleable Iron Threaded Pipe Unions Malleable Iron Threaded Fittings ; ' Pressure-Temperature Ratings Pressure-Temperature Ratings �w ! Pressure Pressure ; � Temperature ;¢ � Class 150 Class 250 Class 300 Temperature Class 300 j (°� (°C) psi bar psi bar psi bar CIaSS 750 Sizes'/"-1" Sizes 1'/"-2" Sizes 2'/z"-3" � -20° -28.9° (6-25 mm) (32-51 mm (64-76 mm) 4-_ to fo 300 20.7 500 34.5 600 41.4 �°�1 (°CJ psi bar psi bar psi bar psi . bar � 150° 65.6° -20° -28.9° � 1d i � � to to 300 2 .7 2 000 1 7. 500 103.4 1 000 68.9 1=' � 0 0 0 , 3 9 1, , � 2 0 0 9 3.3 2 6 5 1 8.3 4 5 5 3 1.4 5 5 0 3 7.9 150° 65.6° f `° 250° 121.1° 225 15.5 405 27.9 505 34.8 200° 93.3 265 18.3 1,785 123.1 1,350 93.1 910 62.7 �U i 300° 148.9° 185 72.8 360 24.8 460 31.7 250° �2r.r 225 15.5 1,575 108.6 1,200 82.7 825 56.9 ; -_ 350° 176.7° 150 10.3 315 21.7 415 28.6 300° 148.9 185 12.8 1,360 93.8 1,050 72.4 735 50.7 I� 400° 204.4° 110 7.6 270 18.6 370 25.5 'o 450° 232.2° 75 5.2 225 15.5 325 22,¢ 350° 176.7 150 10.3 1,150 79.3 900 62.1 650 44.8 i.� ,t 500° 260.0° - - 180 12.4 280 79.3 400° 204.4 - - 935 64.5 750 51.7 560 38.6 ;� 550° 287.8° - - 130 9.0 230 15.9 450° 232.2 - - 725 50.0 600 41.4 475 32.8 ;m ; ', Note:Unions with Copper or CopperAlloy seats are not intended for use where temperature exceeds 500° 260.0 - - 510 35.2 450 31.0 385 26.5 ' � a5o°F 550° 287.8 - - 300 20.7 300 20.7 300 20.7 ��� U FM rc C � �$ Anvil Class 150/300 Malleable Iron Fittings conform to ASME � o � 0 APP6i0VED B163 and Unions conform to ASME B1639 �� For Listings/Approval Details antl Limitations,visit our website @ ' -- www.anvilintl com or contact an Anvil/AnvilStar Sales Representative. ALL EL60WS&TEES 3/8" (70 DN)and LARGER ARE 100%GAS TESTED AT ', A MINIMUM OF 100 PSL (6.9 bar) z /�MOIL . PF-11.10 � 'I I , � / I I� _ ' `; , - _ ,�•~�,`,%w�+�.` ` ; �_-_ •. ',:,Y�,(��r, .` m p:�� ���~ �_ ��,_�����'� ,,��w "r'` _ �.� ���v� . m i v= -�5'' s:'%'.;`':�u��` T��':�;`� i .w� ^3 ':� `+?!'r'�,:.�-:: f'; � .::t ��:._�'M1 � i , .f j . ' •�.�,�. ,:�•=�.:-� r ;.� � �� ' �" iS. - ,-,. ,^'s_ ;f� �y . ' � ; y, ';�:.��t^�HAJ�. I 'f:... �- - "-fF�•'-`."',tti'�Y��".. '{�'�. _ ti'��*�^w:S=�; 'r �:'„ �,. I '�t n��a` :'i� � �----' .}.: t5 �i;�,'[�i',-�y.`�( fy.�!'�5�-ffi+y �.�kj.sy. +. I .Il �.. ,�(� {� A; '�n�'"�.:���'- y 51�:� `�..1 hj�'�LY::��'� /" _ .�� t �„N.-�:�~',L'.�'�f��ri�s�;*! ;��' � t . �, '� •' }�`r:.•, .tzs i�,y �''� � !, :.� �t ��. .'�,.•'�`yr` �" �` � r;?�s � •J l= '•t:. ''�,�.J( ` ; � ���*:;>,o . �� ,�I � �' �':' __� *" �:=_r`;r.;' ,�' � `�.;a�' :�""1, . - y :-;�L '�';.t;: :.:•,� � � a � r,-�. �-_"w ';-`:- ;�ti�.- I`r �,� ,�.r. - - :i - ,l.` :t.,_ - ".\ �j'�•.F`~ J f �1,` ' - ' ' � �/ - ".l;��x-'�{;' F� i�- '`\ r----� t.• .iS�" y.+ `N•-`' Y;l 1 .:i.z .:s?,�_ ,t�. � F::. :��;;.�z.;:--�' � � � -�. : � � �:,. ,�,:,-. �;,� °�+' i 'z` 4/: - ' .,. - GD � ' �a.'J. .? �N � - ` - - 1w..r,, . . . .. ' ' 1'- � '-`s..}. � C + 'i.�,�l.. �l � (d� .'g ai: 't !+' ;R�" � � �LL 'ti•. r..''i. ,-.._ r-...� ��,- �U �f.: f y ' �`�s.• '� - , p \ .�,-, ,�,a �._.__�R,--.-^'^..',��... 'i � l7_�____ I .y � " — ��__��A` .i � ! i •/��` -- i. � vi � ,r �"i .». ... . , ��'jrr ,e'�� „.�.--�—�;:�_' "� y�i r ���i�.tx;-��;;�µ�,�.�r.,:,'�.�LL ; �C ft., -!+` .. Y:. -..,..�.. , :�'y+�;'�.��;�^y3-�x�'*:=aJ,'`�1r�� a� �ti �. .,s ,���yg''�,,.� : , _ - "i'o.t o ; �: � .�:;.. 4,- �-_-- ��` z� �Y � a n � �:� �'`'"'C'•�': `,":,=.,:_ " . +� 1�._- ;.,. :.:,�• ,;.�;,}a;s- �# n"°"` i �� '+1:y -"' '�'z�;t-�� �!'. 'r .,..�.,F� . __ � g,�;:. �~ :� -j .. - - '-'-," m . �� ! '' ` - o �. ,t'' t '.,F,» .,,.,,..- m c ' ���, N� 1 a�+tS � . . -- i i. :c;%���`;>�"�, t ( �c i '=w�& i ` � �LL LL� . ( _ I , -__ " �^ __7 "s � � �� f � � t C FM a � Anvil standard and extra heavy cast iron threaded fittings are C V� U$ o �` manufactured in accordance with ASME-B16.4 (except plugs APPROVED i and bushings,ASME B16.14). Dimensions also conform to Federal For Listings/Approval Details antl Limitations,visit our website Q S ecifications WW-P-501 exce t lu s and bushin s WW-P-471. www.anvilintl.com or contact an Anvil/AnvilStar Sales Re resentative. � � � p � � P P S g ) P � � � U . � � � Cast Iron Threaded Fittings Pressure-Temperature Ratings � -_ � Pressure � � ! Temperature i o � Class 125 Class 250 ;�. (°� (°C) psi bar psi bar {� , -20°to 150° -28.9 to 65.6 175 12.1 400 27.6 k`� � im �� 200° 93.3 165 11.4 370 25.5 '__ .� 250° 121.1 150 10.3 340 23.4 � � ; :'� 300° 148.9 140 9.7 310 21.4 � o , i� , 350° 176.7 125 8.6 300 20.7 ' o 400° 204.4 — — 250 17.2 �" Z /�IV\/1 L � ,�rEw�ar,o�A� PF-9.09 .. : ;�UTJLOI<; �'� ��v�� F � 7 ' Branch Outlet �.: The Gruvlok Fig.7044 Branch Outlet is for direct connection of sprinkler heads and . drop nipples.Just cut a hole,saddle up and fasten it with the U-bolt.The branch outlet provides an economical,quick,and easy outlet at any location along a pipe. , Specially engineered to conform to the pipe O.D.,the Fig.7044 provides a leak tight `�::"'y` S reliable seal in both positive pressure and vacuum conditions.Ductile iron housings R.. ,�; with Grade E gasket and carbon steel U-bolt(3/s"dia.)with flanged nuts.Ductile iron � '1 ��,�� j housings is available black. `�-�,,..�T.-��-. :� The maximum working pressure for all sizes is 175 PSI (12.1 bar). ���.� ',' ; _� c 4L us Fm �, • USTEO APPRDVEO For Llstmgs/Approvel Details antl L1mllaiions, "�;��`°°`"icbs1oetvnvienvd"°`°'"°` HoleDiameter Dimensions SpecifiedTorque§ ,��a�A���P S�a�RaP�sa�,a�Ye. Nominal Approx. Size ��D� Min.Dia Max.Dia A B C Take-out T Min. Max. N►t.Each B In./ON(mm) InJmm InJmm In./mm !n✓mm InJmm In✓mm In./mm FL-LbslN-m LbsJKg ����-� � ����\ 1�/a x Yz 1.660 x 0.840 13/is lYa 2Yis 3Yz 2�/az 13/a 27 33 0.8 A �_ T � -----'�� �-;�-� '--�- - � 32 x 15 42.4 x 21.3 30 32 53 89 56 35 - - 0.4 �.--- --- --- - �--�. '�I� 1�/ax3/a 1.660x1.050 13/s 1�/a 2�/�s 3�/x 2�/az 13/e 27 33 0.8 � ' 32 x 20 42.4 x 26.7 30 32 53 89 56 35 - - 0.4 1�/a x 1 1.660 x 1.315 13/s 1�/a 23/i s 3�/z 2'/3z 1�/x 27 33 0.9 32 x 25 42.4 x 33.7 30 32 56 89 56 38 - - 0.4 CMATERIAL SPECIFICATIONS ; i�i2 X y2 1.soo X o.sao i 3i s i v4 zsi3z a�r2 2�i3z �3�8 2� 33 o.a GASELETS:Materials 40 x 15 48.3 x 21.3 30 32 55 89 56 35 - - 0.4 Properties as designated in accordance with 1 Y2 x 3/a 1.900 x 1.050 13/is 1 Ya 25/az 3Yz 2'/az 13�8 27 33 0.8 ASTM D 2000 40 x 20 48.3 x 26.7 30 32 55 89 56 35 - - 0.4 ❑ Grade"E"EPDM(Green color code) 1 Yz x 1 1.900 x 1.315 13/s 1 Ya Z9�32 3Yz 2'/3z 1�/z 27 33 0.9 -40°F to 150°F(Service Temperature Range 40 x 25 48.3 x 33.7 30 32 58 89 SG 33 - - 0.4 ' (-40°C to 66°C)Recommended for water 2 x Yz 2.375 x 0.840 13/s 1�/a 2Yz 3'/a 2'/az 15/s 27 33 0.8 service,diluted acids,alkalies solutions, 50x 15 60.3x27.3 30 32 64 9S 56 42 - - 0.4 oil-free air and many chemical services. 2 x 3/a 2.375 x 1.050 13/s 1'/a 2Ys 3'/a 27/az 15/e 27 33 0.8 NOT FOR USE IN PETROLEUM APPLICA- 5ox2o 6o.3x26.7 30 32 64 s8 56 42 - - 0.4 TIONS. 2 x 1 2.375 x 1.315 13/is 1 Ya 25/e 3�/s 2'/sz �3�4 27 33 0.9 F30l1SIY�4C�a: SOx25 6U.3X33.7 30 3?_ 67 98 56 45 - - 0.4 Ductile Iron conforming to ASTM A 536, 2Yz x Yz 2.875 x 0.840 13/s l Ya 2"/e 43/s 2'/3z 2 27 33 0.8 Grade 65-45-12. 65x�s 73.Ox21.3 30 32 G9 111 5G 5i - - 0.4 U-B�LT: 2Yz x 3/a 2.875 X 1.050 �3�16 l Ya 2�Yis 43�8 2�/3z 2 27 33 0.9 Plated U-bolt conforming to ASTM A 307 with 65 r2o 73.0 x26.7 3D 32 s9 111 56 51 - - 0.4 plated hex nuts conforming to ASTM A 563. 2y2 x 1 2.875 x 1.315 13/s 1 Ya 213/s 43�8 2'/3x 2�/e 27 33 1.0 �UEf:ICATEf3F�: G5x25 73.Ox33.7 30 32 72 i7i 55 54 - - 0.5 � Standard Gruvlok Not for use in copper systems. ❑ Gruvlok XtremeT^^ §-For additional BoltTorque information,see page 190. See Installation&Assembly directions on page 167 . � ' . i � � � � � i i Project: �Approved Address: ❑Approved as noted Contractor: �Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: GL-7.12 . , • 1 II � , � � , � o • . . . . � � , . � . � 0 � . ��i m ���� ' r�s�- �,,� �T-qq�.{�. 'PL9Ff — ,-: .� -- - - � ,..s 0' - . _ � _ k'��, �� I � _ � �r+ d I 5(IP, ;11�. 6100EL�f011 , — 3 J�Cs t. arLi.w. �.3' _ •The AGF Manufacturing Inc. Model 1011A TESTaNDRA1N�matches all the features and benefits of our Model 1000 by providing both the test function and the express drain function in a multistory installation for a wet fire sprinkler system,with the added feature of an integral Model 7000 Pressure Relief Valve with drainage piping. •The Model 1011A complies with the requirements of NFPA-13 that stipulate a pressure relief valve be installed on all gridded systems and downstream of all pressure reducing valves(see reverse). •The Model 1011A TESTaNDRA1N�is a compact single handle ball valve which includes a tamper resistant test orifice and integral tamper resistant sight glasses, and is 300 PSI rated. •Available in a full range of sizes from 3/a" to 2" NPT and BSPT, with all specifiable orifice sizes 3/e" (2.81n,'/s" (4.2f�, �/2" (5.61n, "/sz" (8.01�, 5/s" (11.2K, ELO), 3/a" (14.OK, ESFR), and K25 as required by NFPA 13, 2007 Edi- tion (see reverse). •The included UVFM Model 7000 Pressure Relief Valve features a flushing handle and is factory rated for 175 PSI. Other pressure settings are available and may be substituted. � Designed to relieve excess system pressure caused by surges or temperature changes as well as solve the dif- ficult problem of providing the relief valve with a convenient drainage-piping outlet. • Shipped with relief valve and bypass drain ports plugged to expedite pressure testing the system. •A locking kit is available and can be ordered with the valve to provide vandal resistance or prevent uninten- tional alarm activation. • Repair kits including(1)adapter gasket, (1) ball, (2)valve seats, (1)stem packing, and (1)stem washer are avail- able for all TESTaNDRA1N�valves.Valve and orifice size must be specified when ordering. NOTE:It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve.Standard relief valves are required to OPEN in a range of pressure between 90%and•105%of their rating.The valves are required to CLOSE at a pressure above 80%of that rating.The relief valve should be installed where it is easily accessible for main- tenance.Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational.A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. i � � r � � � � � r � � TESTANDRAIN Is a registered trademark of AGF Manufacturing Ina CS1011A 10/09 � i • I � � � � , � � 0 � � „ . � � '' ' ,. - . . . DIMENSIONS MODEL '�O'I'I A - FRONT VIEW Orifice Size Available:3/a",�/�s",�/z", ��/sz", ELO(5/a")`, ESFR(3/a")`,&K25" A� SIZE A B C D E F G H E—� ��N�r 3 " �9�16�� 1��2�� 23�16�� 35�g" 33�g" 113�16�� 49�16�� 63�8�� Tp F � � 4 (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) ��H � 79�6�� 1��2�� 23�16�� 35�g" 33�g" 113�16�� 49�6�� 63�8�� � ��� (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) ���4�� 715�16�� 111�16�� 29�16�� 41�q" 35�g" �15�6�� 59�16�� 51�2�� (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 1��2�� 815/16" 113/76�� 3�/4" 5�/ts�� 3�/8�� 25/8" 8�/4" 10�/8" MODEL 1O11A - PLAN VIEW (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) .z�� $15�16�� 113�6�� 3��4�� Jr��l6�� 3��8�� 25�8�� 8��4�� ����8�� � A-DI (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) �O *Available on 1�/a"to 2" size units only '*Available on 1�/2" and 2"size units only To + DRAIN THE MODEL 'IO1'�A PROVIDES ALL OF THE FOLLOWING... �—�I From the 2007 Edition of NFPA 13 1 f C hapter 8.16.2.4.1* Provisions s ha l l be ma de to proper ly drain a ll parts o f the system. + O Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s)- &8.16.2.4.3 shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. �ATERIALS Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling Handle:Steel the flow of the drain. Stem: Rod Brass Chapter A.8.17.4.2 (Wet Pipe System)test connection is permitted to terminate into Ball:C.P. Brass a drain capable of accepting full flow... using an approved sight Body: Bronze test connection containing a smooth bore corrosion-resistant Valve Seat: Impregnated Teflon� orifice giving a flow equivalent to one sprinkler... Indicator Plate:Steel Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. Relief Valve: Bronze Chapter 8.17.4.2.4 shall be permitted to be installed in any location... downstream Bypass Fittings: Brass of the waterflow alarm. Bypass Tubing: Nylobraid Chapter 8.17.4.3.1 (Dry Pipe System)a trip test connection not less than 1" in diameter,terminating in a smooth bore corrosion-resistant orifice, �PPROVALS to provide a flow equivalent to one sprinkler... UL and ULC Listed:(EX4019 Chapter 8.17.4.3.2 The trip test connection...with a shutoff valve and plug not less &EX4533) than 1",at least one of which shall be brass. FM Approved Chapter 7.1.2 -a gridded wet pipe system shall be provided with a relief valve NYC-BSA No.720-87-SM set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure,whichever is greater. Chapter 8.16.1.2.3* A relief valve of not less than�/z" in size shall be provided on the � discharge side of the pressure-reducing valve set to operate at a � pressure not exceeding`175 PSI. ��� , Chapter A.8.16.1.2.3 -consideration should be given to piping the discharge from the MADE IN U.S.A. (pressure reliefl valve . • . � . . AGF Manufacturing Inc. Job Name: 100 Quaker Lane,Malvern,PA 19355 , Phone:610-240-4900 Architect: Fax:610-240-4906 Engineer' www.testandrain.com Contractor: , , PI PE R 11�1 G S � � � �nivi� . gl�. 69 Adjustable Swivel Ring, Tapped Per NFPA Standards _ � __-- -----____._____._._____�_--______._______v_.___..- - ----- __.------ _�._-------___ ___ Size Range:'/z"through 8" � � Material:Carbon steel Finish:0 Galvanized �`. _ f"Y.- Service:Recommended for suspension of non-insulated stationary pipe line. l— -_ Maximum Temperature:650°F Approvals:Complies with Federal Specification A-A-1192A(Type 10) , WW-H-171-E(Type 10),ANSI/MSS SP-69 and MSS SP-58(Type 10). UL Listed and FM Approved(Sizes 3/a"-8"). Features: • Threads are countersunk so that they cannot become burred or damaged. • Knurled swivel nut provides vertical adjustment after piping is in place. • Captured swivel nut in the'/z"through 6"sizes.The capture is permanent in the bottom portion of the band,allowing the hanger to be opened during installation if desired,but not allowing the nut to fall completely out. Ordering:Specify size,figure number and name. Note:The acceptability of galvanized coatings at temperatures above 450°F is at the discretion of the end user. � Metric nut available upon request.Non-captured nut also available upon request. ��A �r'�r A � � � F C B �' t � B /�� F � I C � /1 �\� � -+ f + , ��i�` \\ / 1'/a"through 8"pipe � '/a"through 1"pipe U FIG. 69: LOADS (LBS) • WEIGHT (LBS) • DIMENSIONS (IN) Pipe Size Max Loatl Weight Rod Size A B C F '/z 0.10 2'/e 2 19/s 3�4 �.1� 23�4 ���8 15�6 1 0.10 29/s 1"/s 1 1 Ya 300 0.10 25/a 13/a �/e ���2 0.1� 3�8 Z3�4 1��8 2 0.11 3'/a 23/e 1 Ys 2��2 �.2� 4 23�4 15�6 3 525 0.20 373/e 215/e 13/s 4 650 0.30 4"/,s 313/,s 5 0.54 �JS�6 43/e 19�6 6 1,000 0.65 Yz 6"/s 59/s 2Ya 8 1.00 8 7 2'Ys Note:Reflects changes in rod diameter from previously published data per recent revisions in MSS-SP-58&69 i • � � • i S i � � � i i Project: . ❑Approved � Adtlress: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: � Notes 1: Notes 2: Catalog PH-2008 i • � HANG�ER �RODS ��!w�4 . Flg. 146 Continuous Threaded Rod Size Range:'/a"through 1'/z"Stocked in six,ten,and twelve foot _ lengths.Other even foot lengths can be furnished to order. Material:Carbon steel;rod threaded complete length. Finish:0 Plain or 0 galvanized. Maximum Temperature:650°F. Ordering:Specify rod diameter and length,figure number, name and finish. Note:The acceptability of galvanized coatings at temperatures above 450`F is at the discretion of the end user. Length A FIG. 146: LOADS(LBS)•WEIGHTS(LBS) DIMENSIONS(IN) Rod Size Threads Max Load Weight A per Inch per Fi. 650° F Ya 20 240 0.12 3/s 16 730 0.30 Yz 13 1,350 0.53 5/s 11 2,160 0.84 3/a 10 3,230 1.20 7/e 9 4,480 1.70 1 8 5,900 2.30 l Ya 7 9,500 3.60 1 Yz 6 13,800 5.10 Note:Other rod sizes available upon request.Class 2 fit is available upon request. � � � • � � i • • � � i Project: ❑Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: , Notes 2: Catalog PH-2008 : . , , BEAM CLAMPS ~ � � ���� . Flg. 9z Universal C-type Clamp (Standard Throat) �-- ____._ -�- .__�__— -- - - -- --.-�-�- �- �... ��..� Size Range:'/s"and'/z" � Material:Ductile iron,hardened steel cup point set screw and locknut. Finish:0 Plain or 0 Galvanized Service:Recommended for use under roof installations with bar joist type construction, or for attachment to the top or bottom flange of structural shapes where the vertical hanger rod is required to be offset from the edge of the flange and where the thickness of joist or flange does not exceed'/4: Approvals:Complies with Federal Specification A-A-1192A(Type 19&23) WW-H-171-E(Type 23J,ANSI/MSS SP-69 and MSS SP-58(Type 19&23). UL,ULC Listed and FM Approved. How to size:Size of damp is determined by size of rod to be used. Installation:Follow recommended set screw torque values per MSS-SP-69 -- :-=:� (See table on page 208) Features: • They may be attached to horizontal flanges of structural members in either the top beam or � bottom beam positions. • Secured in place by a cup-pointed Set Screw tightened against the flange. A Jam Nut is provided for tightening the Set Screw against the Body Casting. • Thru tapping of the body casting permits extended adjustment of the threaded rod. - • Can be used with Fig 89X retaining clip for seismic applications. Ordering:Specify rod size,figure number,name of clamp and finish. � �H� C-► �F E AT LEAST ONE I � � � � � FULLTHREAD BE EXP SEDT � � �,. i -_ """'•'.' 3/4 I � BODY - / ' ;" } '• CASTING - I I � � ��� JAM-NUT �–��A � SET SCREW 1• FIG. 92: LOAD (LBS) • WEIGHT (LBS) • DIMENSIONS (IN) • TORQUE (IN-LBS) Rod Size Set Screw Torque Max Loads■ A Size Value Top Bottom Weight C D E F G H 3�8 3�8 6� �J�� 2�J� 0.34 �5�6 �9�16 9�6 13�16 3�8 ��2 Yz Yx 125 950 760 0.63 13/e 113/s Y� 1'/,s �/s Z3�32 ■Maximum temperature of 450°F . � � . , � � � • � t i Project: ❑Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: � Notes 1: Notes 2: Catalog PH-2008