HomeMy WebLinkAbout18-19189 CITY OF ZEPHYRHILLS
5335-8TH STREET
� � �sis)�so-oozo 19189
� BUILDING PERMIT SINGLE FAPiIILY RESIDENTIQ►L
PERMIT INFORMATION LOCATION INFORMATION
Permit#:19189 Issued: Address: 6693 WAGON TRAIL ST
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 252,110.70 Total Fees: 11,327.19 Subdivision: SILVERADO
Amount Paid: 11,327.19 Date Paid: 1/16/2018 Parcel Number: 05-26-21-0080-00600-0420
I CONTRACTOR INFORMATION OWNER INFORMATION
Name: D R HORTON INC Name: DR HORTON INC
Addr: 12602 TELECOM DR Address: 12602 TELECOM DR
I TAMPA, FL. 33637 TEMPLE TERRACE FL 33637-0935
Phone: Lic: Phone: 813-549-1968
i Work Desc: CONSTRUCT SINGLE FAMILY 2,238 SQ FT
, APPLICATION FEES
B I DING FEE 1,042.88 ELECTRICAL FEE 212.40 PLUMBI G FEE 141.60
MECHANICAL FEE 99.12 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
I' PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00
SCHOOL IMPACT FEE-sfd 1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
�,,e/ `��` �(,�' ��
�i1 b - � �
� R,es�rc��G��.�
`
Ins ections Re uired �,
FO ER 2ND R UG PLUMB MIS INSULATIO CEI IN I
I FOOTER BOND DUCTS INSULATED SEWER MISC. �i
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REIMSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local.government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this properly that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your properly. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
�
CONTRACTORS SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
I
: �
DR Horton-6693 Wagon Trail St-2,238;sq ft
� • .;=""''
o umn
SQ. FEET �• PRICE
MAIN OR LIVING: 2,238 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 252,110.70
FEE SHEET $ 944.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,042.88
ELECTRICAL: $ 212.40
PLUMBING: $ 141.60
MECHANICAL: $ 99.12
SUB-TOTAL $ 1,496.00
TOTAL $ 1,496.00
SEW ER: n/a
WATER: n/a
IRRIGATION: $ -
TOTAL: $ -
WATER METER: n/a
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 2,049.35
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00 �
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 11,327.19
� i iiiiii iiiii iiiii iiiii iiiii iiiii.iiiii iiiii iiiii iiiii iiii iiii
2017201445
� • • Rcpt:1918441 Ree: 10.00
DS: 0.00 IT: 0.00
� , 12/21/2017 K. M. , Dpty Clerk
Permit No. Parcel ID No �S- Z(n�2����$U' ��G O- ��z� '
NOTICE OF COMMENCEMENT
State of � r I �_ County of �Qs�
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,
the following information is provided in this Notice of Commencem(ent:�1 �1 r- � ry / ,�1.
1. Description of Property: Parcel Identification No. LO'1` _I Z v1 bC�. l0 ` t )►IUt'1"G�:� '11'1Q�S� l���, '�-�'l rl
Street Address. `"1 �I �� F �
2. General Description of Improvement �'Q7.� J l ��l �� CL VI/��► I� ��i i12i� �.�
PRULq S 0'NEIL,Ph D PqSCO CLERK & COMPTROLLER
3. Owner Information or Lessee information if the Lessee contractetl for the improvement: _ 12�21/2017 09:32am 1 of 1 I
�•. � IU��-tl/� �/1 � --�R _BK—��52--PG 2��� -
1 Z('o O� "�°'e.I-P��n�t � r �v►�t.r/�e� c���o3� �C.
Address City�— State
Interest in Property: �e� ���Vl.i� ��.
' Name of Fee Simple Titleholder:
(if different from Owner listed above)
Address -� n ' �I�r���� City State
4. Contractor �1
���O��ame��P.IC'�OM ��' �41M�Q �.��g�3 � IC�-
Address Ci y State
Contractor's Telephone No.•
5. Surely: ���-
Name
Address City State
Amount of Bond: $ � �� Telephone No..
6. Lender• a��/y.-
' Name
Address City - Sfate
Lender's Telephone No.
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7), Florida Statutes:
1, QI/�'� C��9�-�
Nam�
Idresd s I-�' ���.�r�l �� i�U�i(-�//� ��c?�?•_) � �
Telephone Number of Designated Person: ���(�_���� State
8. In addition to himself,the owner designates ,�/�/7 of
-�
to receive a copy of the Lienor's Notice as provided in Section 713 13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner
9. Expiration date of Notice of Commencement (the expiration date may not be before the cdmpletion of construction and final payment to the
contractor,but will be one year from the date of recording unless a different date is specified).
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATrORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best
of my knowledge and belief.
STATE OF FLORIDA �
COUNTY OF PASCO �
Signa ure of Owner or Lessee,or Owner's or Lessee's Authorized
Office 0irectorlPartner/Manager
�SSf. � ��'P:�/'�/ - ]�•'�,�n����r
Signatory's Title/O�ce
The foregoing instrument.was acknowledged before me this[r► day o�WQ��201�by_ I°I'�Q(/� c�"f'"(�L���Q.✓��
as���� �Pr���C��/ (type of authority,e.g.,o�cer,trustee,attorney in fact)for
1 . �+�o�-1-bn Tr�� (name of party on behalf of whom instrument was executed).
� ��I, ���-
Personally Known[�OR Produced Identification❑ Notary Signature ��6�, .(�
l"ype of Identification Produced Name(Print) . ' ` /
` ' j i _
� �i1
.�'�o�q " �NOtery PuUlic Ste4e of Fiorida
��°.��;; Mlchelle Moyes, .
'� � a �My Coinmisslon GG 057321
' �of�d� ExplreeY92l21f2020 _
wpdata/bcs/not(cecommencement_pc053048 , ' .
II
� � �ai���
�:. � �o
sr���oF F�o�i��,�ou�rY o��Asco � �o �����'' �`��'�� ��
7HIS IS TO CERTIFY�HAT THE FOREGOING I � . n� � �
TRUE AND CORRECT,CdPY OF TNE DOCUMENT � 0; J^•�. "` '. � a �
�F t � ��� � w,.
ON 61L�-t�R fjf-�,.(;�gUC RECORD IN THIS OF �,�:, ��.;i�'s-� � y � �
W�T N E S S M Y►��N p N D O F F I CIAL SEAL THIS�C E �-�'� x"��`��4
� �F
�DAY OF �����` �
P A U L A S O'NEIL;CLER &COMPTRO�E �� u
��'•e d . �
eY ���e's�.b.�'
—`—'" DEPUTY CLERK
I
4� � '
.��1f�_;',lLOHiBA� � .
-��""_"'�_-
� � . �..�. �� '
. '„r'-"o'.i "
;✓.
City o£Zephyrhills
BUILDTNG PLAN REVT.EW COMMENTS
. �
Contractor/Homeowner: � c�'..6��
Date Reeeived:
Site: �g � � `�� �-' 6
Perrnit Type: �1 1�-0 2- G�� C��
�
Appraved w/no cpmments:❑ Approved wlthe belaw cor�unents: Denied wlthe belaw comrnents: ❑
�
,
This comment sheet shall be kept with the pernut a.xad/or plans.
�
Kalvin Switzer-Plans Examiner L}ate Contractor andlor Homeowner
(Required when comments are present)
��
�� - -- - - - - --,� _ . -_ _ _..__ _ - _ - - -� -- �- -- -..- - _. -- _. ---. _ _ . - : _. � _ _-�_ . , '
� - - -=-" - - - - -- -- - - --- - ... . _ -
, I
:
�, .
' FORM R405-2014 -
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Aria Elevation D��` Builder Name: DRH Express Hpmes�, ,�
Street: � � G� � < } Permit Office: "� ;� ln �r-
City,State,Zip: �Zeph�/r�FL������ ��Z�� �v Permit Number�($� �
Owner: �� �� 2I� Jurisdiction: (Q �� �
Design Location: FL,Tampa � � County•• Pasco�lorida Climate Zone 2)
1. New construction or existing• New(From Plans) 9. Wall Types(1658.2 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1372.20 ftz
b. Frame-Wood,Adjacent R=11.0 286.00 ftz
� 3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 3 d.N/A � R= ftz
5. Is this a worst case? No 10.Ceiling Types (1672.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 1672.00 ftz
6. Conditioned floor area above grade(ftz) 1672 b.N/A R= ftz
Conditioned floor area below grade(ftz) 0 c.N/A R= ft2
11. Ducts R ft2
7 Windows(182.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 334
a. U-Factor: Dbl,U=0.34 142.00 ftz
SHGC: SHGC=0.31
b. U-Factor• Dbl, U=0.55 40.00 ftz 12•Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00
c. U-Factor• N/A ftz
SHGC• 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftz a. Electric Heat Pump 28.6 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 4.985 ft.
� Area Weighted Average SHGC: 0.317 14.Hot water systems
8. Floor Types (1672.0 sqft.) Insulation Area a.Electric Cap:50 gallons
EF.0.950
a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ftz b. Conservation features
b.N/A R= ftz None
c.N/A R= ft2 15.Credits Pstat
Total Proposed Modified Loads: 56.48 pASS
Glass/Floor Area: 0.109
' Total Baseline Loads: 57.14
I hereby certify that the plans and specifications covered by Review of the plans and ��T�E�T'qx,�
this calculation are in compliance with the Florida Energy specifications covered by this �� '� � � , O
Code. calculation indicates compliance �'w'�i„�'''% `=-'-',o� �„
with the Florida Ener Code. ti �rt ���-.":,__;���;;.•�� O
9Y „�, s�, ::� a
PREPARED BY: LMI� ,,,o.�.. Before construction is completed w �� �
�e t'�, �
DATE: ia-3o-n this building will be inspected for � '�t�E�t,��
compliance with Section 553.908 * � '° �,
I hereby certify that this building, as designed, is in compliance Florida Statutes. j� A -��
with the Florida Energy Code. �''OD���
OWNER/AGENT: �' ' BUILDING OFFICIAL:
DATE: t l l. DATE• ' '
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as I
certified factory-sealed in accordance with R403.2.2.1. �
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
a
10/30/2017 11•11 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4
;
�, .
• FORM R405-2014 •
FLORIDA ENERGY- EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional-Regulation - Residential Performance Method
Project Name: Aria Elevation D Builder Name: DRH Express Homes
Street: �j����,;_GC' �i�� � i < } Perrnit Office:
City,State,Zip: Zeph hit ,FL,vn��l ���2t� �1 ,v Permit Number:
Owner: �� -1 ���f� Jurisdiction:
Design Location: FL,Tampa � � County:: Pasco(Florida Climate Zone 2)
1. New construction or existing- New(From Plans) 9. Wall Types(1658.2 sqft.) - Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1372.20 ftz
b.Frame-Wood,Adjacent R=11.0 286.00 ftz
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
10.Ceiling Types (1672.0 sqft,) Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1672.00 ftz
6. Conditioned floor area above grade(ftz) - 1672 b.N/A R= ftz
Conditioned floor area below grade(ftz) 0 c.N/A R= ftz
11 Ducts R ftz
7. Windows(182.0 sqft.) Description Area a.Sup:Attic, Ret:Main,AH:Main 6 334
a. U-Factor: Dbl, U=0.34 142.00 ftz
SHGC: SHGC=0.31
b. U-Factor: Dbl, U=0.55 40.00 ft2 12•Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00
c. U-Factor: N/A ftz
SHGC: 13.Heating systems kBtu/hr Efficiency-
d. U-Factor: N/A ftz a.Electric Heat Pump 28.6 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 4.985 ft.
Area Weighted Average SHGC: 0.317 14 Hot water systems
a.Electric Cap:50 gallons
S. Floor Types (1672.0 sqft.) Insulation Area
a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ftz EF.0.950
b. Conservation features
b.N/A R= ftz None
c.N/A R= ftZ 15.Credits Pstat
Total Proposed Modified Loads: 56.48 n A��
Glass/Floor Area: 0.109 Total Baseline Loads: 57.14 rf1
I hereby certify that the plans and specifications covered by Review of the plans and �.��SES�,��,�
this calculation are in compliance with the Florida Energy specifications covered by this �� = .; p
Code. calculation indicates compliance �'c+',,,,°''��� z=;',� �,,,�
�.°.o ic"
with the Florida Energy Code. N �rtrrr.':.,'��:;:<::;;..',;��,;,�`�„ o
PREPARED BY: L'N1�- .,,,,�... Before construction is completed � ' �
DATE: i -3o-i� this buildin will be ins ected for � j''' _ ~ ,q;
9 P t7 _`l,i�-
compliance with Section 553.908 * l�. �' �
I hereby certify that this building, as designed, is in compliance Florida Statutes. ,� _ '. �,S
with the Florida Energy Code. D��¢�
OWNER/AGENT: -����"���' � BUILDING FFICIAL:
DATE: Il , DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
. certified factory-sealed in accordance with R403.2.2.1. �
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
10/30/2017 11:11 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
i
� .
� •
, FORM R405-2014
PROJECT �i
Title. Aria Elevation D Bedrooms: 3 Address Type: Lot Information
Building Type: User Conditioned Area: 1672 Lot# 42/6
Owner: Total Stories: 1 Block/SubDivision: Silverado Ranch
#of Units: 1 Worst Case: No PlatBook:
Builder Name: DRH Express Homes Rotate Angle: 180 ' -'" Street:
Permit Office: Cross Ventilation: - County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: Garage R Face S
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
\/ Design Location TMY Site � Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Blocki 1672 14496.2
. SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated
1 Main 1672 14496.2 Yes 4 3 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 192.68 ft 0 1672 ftz ____ 0.5 0 0.5
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
\/ # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 1870 ftz O ftz Dark 0.92 No 0.9 No 0 26.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1672 ft2 Y N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 1672 ftz 0.11 Wood
�
1 0/30/2017 1 1•11 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
� •
, FORM R405-2014
WALLS I
Adjacent Cavity Width - Height Sheathing Framing Solar Below I
Space
0
� _ 1 'N=>S Exterior Concrete Block-Int Insul Main 4.0999 18 0 S 8 156.0 ftz 0 0.6 0
_2 W=>E Exterior Concrete Block-Int Insul Main 4.0999 44 0, 8 8 381.3 ftz 0 0.6 0
_3 S=>N Exterior Concrete Block-Int Insul Main 4.0999 38 8 8 8 335.1 ft2 0 0.6 0
_4 E=>W Exterior Concrete Block-Int Insul Main 4.0999 57 8 8 8 499.8 ftz 0 0.6 0
_5 N=>S Garage Frame-Wood Main 11 20 0 S 8 173.3 ftz 0.23 0.01 0
_ 6 W=>E Garage Frame-Wood Main 11 13 0 S 8 112.7 ftz 0.23 0.01 0
DOORS '
# Omt Door Type Space Storms U-Value Width Height Area
� Ft In Ft In
1 N=>S Insulated Main None .4 3 6 8 20 ftz
2 N=>S Wood Main None .46 2 8 6 8 17.8 ftz
WINDOWS
Orientation shown is the entered orientation => chan ed to As Built rotated 180 de rees .
/ Wall Overhang
\/ # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N=>S 1 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 2 ft 8 in 0 ft 1 in Drapes/blinds Exterior 5
2 N=>S 1 Vinyl Low-E Double Yes 0.34 0.31 2.5 ftz 7 ft 8 in 0 ft 2 in Drapes/blinds Exterior 5
3 S=>N 3 Vinyl Low-E Double Yes 0.34 0.31 62.0 ftz 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5
4 S=>N 3 Vinyl Low-E Double Yes 0.34 0.31 31.0 ftz 8 ft 0 in 0 ft 1 in Drapes/blinds Exterior 5
5 E=>W 4 Metal Low-E Double Yes 0.55 0.34 40.0 ft2 12 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 .
6 E=>W 4 Vinyl Low-E Double Yes 0.34 0.31 15.5 ftz 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 432.177 ftz 432.177 ftz 49 ft 8.67 ft 0
INFILTRATION
# Scope Method SLA CFM 50 ELA EqLA - ACH ACH 50
1 Wholehouse Proposed ACH(50) .000386 1691.2 92.85 174.61 .2892 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump None HSPF:8.2 28.6 kBtu/hr 1 sys#1
10/30/2017 11:11 AM EnergyGaugeC�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2014
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit None SEER:14 28.6 kBtu/hr 858 cfm 0.75 1 sys#1
.�
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation�
1 Electric None Garage 0.95 50 gal 70 gal 120 deg None "
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftz
DUCTS
/ ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
\/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 334 ftz Main 40 ftz Default Leakage Main (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Coolin Jan Feb Mar A r Ma Jun Jul Au Se Oct Nov Dec
Heatin9 Jan f X}Feb f X�Mar �APr E �May 4�Jun f�Jul f�Aug f�SeP E�Oct �Nov �Dec
Ventin Jan [ ]Feb [X]Mar A r [ Ma � Jun [ Jul [ Au [ Se [X]Oct Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 . 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
' PM 68 68 68 68 68 68 68 68 68 68 66 66
1 0/30/2017 1 1•11 AM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 4 of 4
� FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index,the more efficient the home.
, Zephyrhills, FL,
' 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 137220 ftz
b.Frame-Wood,Adjacent R=11.0 286.00 ftz
3. Number of units,if multipie family 1 c.N/A R= ftz
4 Number of Bedrooms 3 d.N/A R= ftz
5. Is this a worst case? No 10.Ceiling Types Insulation Area
a.Under Attic(Vented) R=30.0 1672.00 ftz
6. Conditioned floor area(ftz) 1672 b.N/A R= ftz
7. Windows" Description Area c.N/A R= ftz
a. U-Factor: Dbl,U=0.34 142.00 ftz 11. Ducts R ft2
a.Sup:Attic,Ret:Main,AH:Main 6 334
, SHGC: SHGC=0.31
, b. U-Factor: Dbl,U=0.55 40.00 ft2
SHGC: SHGC=0.34 12.Caoling systems kBtu/hr Efficiency
' c. U-Factor: N/A ft2 a.Central Unit 28.6 SEER:14.00
SHGC:
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 28.6 HSPF:8.20
Area Weighted Average Overhang Depth: 4.985 ft.
Area Weighted Average SHGC: 0.317
8. Floor Types Insulation Area 14 Hot water systems
z a.Electric Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ft EF:0.95
b.N/A R= ` ftz
c.N/A R= ftz b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building �.�KE srR�, -
Construction through the above energy saving features which will be installed (or exceeded) yo - � � �o
in this home before final inspection. Otherwise, a new EPL Display Card will be completed �;v�`,,,;''%.' :'��,.t �
based on installed Code compliant features. � rn;,,'�--: =�:�;;°;;��;;,,ro�
s�. �.:t`.�ui.
Builder Signature:..-!-��,�/L�}-zy,� , Date: ( c� s>;(� �
v a -�-�� � * �.� z
Address of New�Home:���� � ��(a�.�����l�� City/FL Zip� ',, �- �co ��c,'�
� •
. ��<< D`�-
. �
Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
*"Label required by Section.R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
10/30/2017 11:12 AM EnergyGauge�USA-FlaRes2014 -Section R405.4 1 Compliant Software Page 1 of 1
FORM R405-2U14 �
� � Florida Department of Business and Professional Regulations
Residential Whole Buildin Performance and Prescri tive Methods
ADDRESS: Permit Number:
Zephyrhills, FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
� 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy pertormance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for oecupancy.Florida law
[Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display,card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C
� R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage iri accordance with the requirements of
Sections R402.1 through R402.4.4.
Q R402.4.7 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4 1.1 and R402.4.1.2.The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
• R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in
accordance with the manufacturer's instructions and the criteria listed in Table 402.4 1.1,as applicable to the method of construction.
Where required by the code official,an approved third party shall inspect all components and verify compliance.
• R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air
changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an
approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures;
2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures,
3.Interior doors,if installed at the time of.the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air.
O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
� R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
, � R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
� that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
� R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance
with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction
or rough-in testing below.
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section
553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following:
1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All
register boots shall be taped or otherwise sealed during the test.
2. Rough-in test:Total leakage shall be less than or equal to 4 cfm (113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be
taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm
(85 Umin)per 100 square feet(9:29 m2)of conditioned floor area. �
Exceptions:
1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope.
2. Duct testing is not mandatory for buildings complying by Section R405 of this code.
� 10/30/2017 11:12 AM EnergyGauge�USA-FlaRes2014 -Section R405.4 1 Com Page 1 of 3
• FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
� R403.2.3 Building Cavities(Mandatary). Building framing cavities shall not be used as ducts or plenums.
❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capabl�of carrying fluids above 105°F(41°C)
or below 55°F(13°C)shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping insulation.
� R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can turn off the hot-water circulating pump when the system is not in use.
� R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 Yz inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
� R403.4.4 Water heater efficiencies(Mandatory).
� R403.4.4.1 Storage water heater temperature controls
. R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum
temperature setting range shall be from 100°F to 140°F(38°C to 60°C).
. R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off.A separate valve shall be provided to permit the eriergy supplied to the main burner(s)
of combustion types of service water heating systems to be turned off.
0 R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4 4.2.1.
. R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar pomestic Hot Water System and Component Test Protocol,Collectors in installed solar water
heating systems should meet the following criteria.
1 Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
p R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment.
� R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1 This code does not allow designer safety factors,provisions for future expansion or other factors
which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems. �
• R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
10/30/2017 11:12 AM EnergyGaugeC�USA-FlaRes2014 -Section R405.4 1 Com Page 2 of 3
• FORM R405-2014
MANDATORY REQUIREMENTS - (Continued) �
� R403.6.1.1 Caoling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and
shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This
selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the
load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for;he indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions: -
1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the -
calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of
, equipment may be sized in accordance with good design practice. .
� R403.6.1.2 Heating equipment capacity
' R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section
R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
. R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.6.1
' R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.6.1.
� R403.6.1.3 E�ctra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum pertormance during base load periods is utilized.
❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall
include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F.
❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and
inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy
requirements for portable spas shall be in accordance with ANSI/APSP-14.
Q R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
� R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum
thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
� R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in
compliance with this equipment.
Exceptions:
• 1. Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or
at the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or
' solar energy source computed over an operating season.
❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be
, high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps.
� R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
� R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
O R405.2.1 Pertormance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or �i
concrete deck roofs do not have sufficent space, R-10 is allowed. I
10/30/2017 11:12 AM EnergyGaugeC�USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
�
Project Name: Aria Elevation D Builder Name: DRH Express Homes
Street: . - Permit Office:
City,State,Zip: Zephyrhills, FL, Permit Number:
� Owner: Jurisdiction:
Design Location: FL,Tampa �
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. .
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attiC The air barrier in any droppeii ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings,drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim 'oists Rim joists are insulated and include an air barrier. �
• Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking. I
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped. •
Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings tc�exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled -
by insulation that on installation readily conforms to the available cavity
s aces.
� Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated,and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls,or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
EleCtriCal/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
10/30/2017 11:12 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: Aria Elevation D Builder Name: DRH Express Homes
Street: Permit Office: -�
City,State,Zip: Zephyrhills, FL, Permit Number:
Design Location: FL,Tampa Jurisdiction:
Cond.Floor Area:: 1672 sq.ft. Cond.Volume: 14496 cu ft.
Envelope Leakage Test Results Leakage Characteristics
Regression Data:
C: n: R:
CFM(50):
Single or Multi Point Test Data
HOUSE PRESSURE FLOW: E�'
1 Pa cfm EqLA:
2 Pa cfm ACH:
3 Pa cfm
ACH(50):
4 Pa cfm
5 Pa cfm -
SLA:
6 Pa cfm
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour
in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2
inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party A written report of the results of the
test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
' During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other
infiltration control measures; . '
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration
control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
I hereby certify that the above envelope leakage W here required by the code official, ��'��E S�'A��,
performance results demonstrate compliance testing shall be conducted by an � ,,,,ti ��_�, �,,�,
with Florida Energy Code requirements in approved third party. A written � '��f�°i - �O �
� TtJiif�°'`'y, c�"x•°.``�S`",�4 (�
- a c c o r d a n c e w i t h S e c t i o n R 4 0 2.4.1.2. r e p o rt o f t h e r e s u l t s o f t h e t e s t s h a l l � "'�'':,'
be signed by the third party � . ���{ . v
� conducting�the test and provided to � 4`"� n �
SIGNATURE: the code official. * � � �`
PRINTED NAME: - j���������
BUILDING OFFICIAL:
DATE: DATE:
� 10/30/2017 11:12 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
� Manual S Com liance Re ort Job:
-�- wrightsoft� p p �ate: ooc,o,zo,a
Entire House Bv�
Progressive Air Systems, Inc
5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669
� • ' • •
For: DR Horton
Lot 42 Blk 6 Silverado Ranch, Zephyrhills, FL
. • o • •
Design Conditions
Outdoor design DB: 91.2°F Sensible gain: 21334 Btuh Entering coil DB: 76.1°F
Outdoor desi n WB: 77.1°F Latent ain: 2877 Btuh Enterin coil WB: 63.0°F
9 9 9
Indoor desi n DB: 75.0°F Total ain: 24211 Btuh
9 9
° fm
Indoor RH: 50/o Estimated airflow: 1000 c
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: SpIitASHP
Manufacturer: Carrier Model: CH14NB030""*"A+FB4CNP030
Actual airflow: 1000 cfm
Sensible capacity: 23532 Btuh 110%of load
Latent capacity: 3786 Btuh 132%of load
Total capacity: 27318 Btuh 113%of load SHR: 86%
. • . -
Design Conditions
� Outdoor design DB: 40.0°F Heat loss: 20312 Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: CH14NB030'*"`A+FB4CNP030
Actual airflow: 1000 cfm
Output capacity: 25625 Btuh 126%of load Capacity balance: 31 °F
Supplemental heat required: 0 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 1000 cfm -
Output capacity: 6.4 kW 108%of load Temp. rise: 20 °F
Meets are all requirements of ACCA Manual S.
.� wri htsoft� zo,�-o�c-so„�,a:,s
�� 9 Right-Suite�Universal 2017 17.0.21 RSU25554 Page 1
�'�` .on\Wrightsott Files\Express homes�Aria 4EAB.rup Calc=MJ8 House taces: S
� 1 .
" Load Short Form ��b�
-�- wrightsoft� Date: Oct 10,2014
Entire House By:
Progressive Air Systems, Inc
5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669
� • ' � •
For: DR Horton
Lot 42 Blk 6 Silverado Ranch, Zephyrhills, FL
i - o • a -
� Htg Clg Infiltration
Outside db(°F) 40 91 Method - Simplified
Inside db (°F) 70 75 Construction quality Semi-tight
Design TD (°F) 30 16 Fireplaces 0
Daily range - L
Inside humidity (%) 50 50 �
Moisture difference(gr/Ib) 26 54
HEATING EQUIPMENT COOLING EQUIPMENT
Make Carrier Make Carrier
Trade CARRIER Trade CARRIER
Model CH14NB030""A , Cond CH14NB030�""A
AHRI ref Coil FB4CNP030
AHRI ref
Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER
Heating input Sensible cooling 22500 Btuh
Heating output 29600 Btuh @ 47°F Latent cooling 7500 Btuh
Temperature rise 27 °F Total cooling 30000 Btuh
Actual air flow 1000 cfm � Actual air flow 1000 cfm
Air flow factor 0.049 cfm/Btuh Air flow factor 0.047 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.88
Capacity balance point=31 °F
Backup:
In ut=6 kW, Out ut= 21934 Btuh, 100 AFUE �
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
- (ft2) (Btuh) (Btuh) (cfm) (cfm)
M bed 237 3345 3280 165 154
dining 202 2812 3947 138 185
greatroom 257 3318 4133 163 194
M wic 49 744 338 37 16
wc 25 372 169 18 8
M bath 135 1579 845 78 40
kitchen 146 170 1547 8 73
laundry 42 252 843 12 40
A/C closet 14 16 25 1 1
bed3 154 1615 1675 80 79
foyer 162 1679 1494 83 70
bath2 60 659 322 32 15
bed2 166 3751 2716 185 127
Calculations approved by ACCA to meet all requirements of Manual J Sth Ed.
.� wri htsoft" 2017-Oct-3011:14:15
,..`� 9 Right-Suite�Universal 2017 17.0.21 RSU25554 Page 1
�+� .on\Wrightsoit Files\Express homes�Aria 4EAB.rup Calc=MJ8 House faces: S
. l
Entire House d 1647 20312 21334 1000 1000
Other equip loads 0 0
Equip. @ 1.00 RSM 21334
Latent cooling 2877 _
TOTALS 1647 20312 24211 1000 1000
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
.� wri htsoft6 2017-Oct-3011�14:15
^, 9 Right-Suite�Universal 2017 17.0.21 RSU25554 Page 2
�� .on\Wrightsoit Files\E�ress homes\Aria 4EAB.rup Calc=MJS House faces: S I
. ` -
Pro ect Summar Job:
� wrightsoft� Entire House y Byte: o�t,o,20,4
Progressive Air Systems, Inc
5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669
� • ' � !
- For: DR Horton
Lot 42 Blk 6 Silverado Ranch, Zephyrhills, FL
Notes:
� - • s •
Weather: Tampa Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 40 °F Outside db 91 °F
Inside db 70 °� Inside db 75 °F
Design TD 30 °F Design TD 16 °F
Daily range L .
Relative�humiclity 50 % ,
Moisture difference 54 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 16693 Btuh Structure 16219 Btuh
Ducts 3619 Btuh Ducts ' 5114 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 20312 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 21334 Btuh
Method Simplified Latent Cooling Equipment Load Sizing �
Construction quality Semi-tight
Fire laces 0 Structure 2231 Btuh
P Ducts 646 Btuh
Central vent (0 cfm) 0 Btuh
� Heating Cooling none
2 �. )
Area(ft 1647 1647 Equipment latent load 2877 Btuh
Volume�ft3) 14494 14494
� Air changes/hour 0.26 0.14 Equipment total load 24211 Btuh
, Equiv.AVF(cfm) 63 34 Req. total capacity at 0.75 SHR 2.4 ton
Heating Equipment Surr�mary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER Trade CARRIER �
Model CH14NB030"'*A Cond CH14NB030'��'A
AHRI ref Coil FB4CNP030
, AHRI ref
Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER
Heating input Sensible cooling 22500 Btuh
Heating output 29600 Btuh @ 47°F- Latent cooling 7500, Btuh
Temperature rise 27 °F Total cooling 30000 Btuh
Actual air flow 1000 cfm Actual air flow 1000 cfm
Air flow factor 0.049 cfm/Btuh Air flow factor 0.047 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.88
Capacity balance point=31 °F ,
Backup:
Input=6 kW, Output= 21934 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J°8th Ed. ,
.�, wri f'1'tSOft`° 2017-Oct-3011•14:15
��� g Right-Sui[e�Universal 2017 17.0.21 RSU25554 Page 1
.on\Wrightsoft Files\E�ress homeslAria 4EAB.rup Calc=MJ8 House faces: S
�
FORM R405-�014 �
RES/DENT/AL ENERGY CONSERVATION CODE DOCUMENTATION CHECKL/ST
Florida Departmenf of Business and Professional Regulation
Simulated Performance A/fernative(Performance)Mefhod
Applicafions for compliance with the 2074 F/orida Building Code, Energy Conservation via the
residential Simulated Performance method shall include
❑ This checklist .
❑ A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, e-ratio and the pass or fail status along with summary
areas and fypes of components, whether the home was simulated as a worst-case
orientation, name and version of the compliance software tool, name of individual ,
completing the compliance report(1 page)and an input summary checklist ihat can
be used for field verification (usually 4 pages/may be greater). -
❑ Energy Performance Level(EPL)Display Card(one page)
❑ Mandatory Requirements(three pages)
Reguired prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report(usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
� Form R405 Duct Leakage Test Report(usually one page)
EnergyGauge�-USRCZB v5.1
1 0/30/201 7 2:01:27 PIV1 Page 1 of 1
.� I
i �ASCO COURITY, �FLORIDA
� Permit No. B�
' Date Permftte /��_�B
Builder Name/Owner Name ��/C ���j� G� Control#
,� County Parcel No. (�_�'_Z��0&jT/�!�(o�z ,.0�2oSubDiv: s' �
Y AddresslLocation �Q l� 3 c S
'` ClassiflcatioNType of Use �'� �� f
�,`� TRANSPORTA�'ION IMPACT FEE Rate: Sq.Ft Unit: 2� �3$
i�:
` Exempt � Yes � No How Determined
`� � Im act Fee Amount $, 3(Q���
P Zone No. Tp,Z:
�`" � SCHOOL IMPACT FEE
,..
Account (056) Single-Family Detached House Amount $ ��j 7�� Z�
� (057) Mobile Home
', (058) Other Residential
� 123) Collection Fee
Exempt [�Yes [�No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total �
Recreation Account Recreation Credlt -Recreation Total
Zona TOTAL AMOUNT $ 2�� ��
Exempt � Yes � No How Determined
- LIBRARY FEE
_ Land Accounf Land Credit Land Tptal
� Facility Account Facility Credit Facility Total
Exempt � Yes � No How Determined Total Amount �/_
RESOURCE FEE ERU '
TOTALAMOUNT
Prepared By Checked By i
- NO CERTIFICAYE OF OCCUPANCY WILL BE ISSUED OR FINAL INSI'ECTION
.. PERFORMED U(dTIL THE TOTAL AMOUN7S LISTED HAVE
�EEN PAID AND
r RECEIPTED FOR BY,4 CENTRAL PERMITTING OFFICE�OF PASCO COUNTY
r Acknowledgement below doea not imply acceptance of concurrenca,but simpty recelpt of a copy of this form,placing
`- the bullding pertnit owner on notice of thls assessment and thQ condiUons of payment for same.
DATE RECEIVED BY
� RECEIPT NO. DATE gy
� ' -. pasco.couNr�r
A { DEVELOpMEFfT SERVICES
���'� 8'731 Citizens Drive Date:4/27/2018
�1 :1��� ' :,
�
�(7UIV'I"Y FLURIDA New Pott RicEiey,F�'34654
t�r>ta�i Sr�s..G'�c,uan�r�Pwe;�s. ' 727-847-2411
'�* lVC�T A PER6�i�IT **
Receipt#: 1755729
FEE DESCRIP710N ACCOUNT GODE UNITS INVOICE# FEE AMQUNT PAID .RECEIPT# QATE
lmpact Fee Resldentia!Solid 295039QQ-329010 42.46 7339925 $42:48 $42.4$ 'E755729 4127i18
Waste Single Family
TOTALS: $42.48 542.48
Receipt# Fal_ d 8v Check# CC Auth# Casfiier tD Workstation Receiat Date mt-Paid
1755729 Check 738987 �40 BCCCPO6W 04J27/2018 �42.48
, Total Payments: 542.48
�I
, Pa or Address Phone
' D R Horton 134'1 Horton Circle
� Arlington,T?C T6011
� �ts:
City+of Zephyrhiiis
� Permit19188
'i 6693.WagonTrail�Street
I
Parcel;05 26 21 0080 00600�420
I While you wi8 be peyi�g your b111 with Pasec toun evetapment SerJtces,the fu(1 amoani ofi the crcdlt card or e�thetk fees,N07 shown above,is coltected 6y
First BIIIing payment services.
�
�
#
l
1
} �
� li
!
� �
I
�
l
( �
I
� ��i
� �� �
�i �
�
�
i
i
I
MyReports/reportsl/PRODUCTION/FASCO/ReceipfPOS VS.rpt 4/27J2018 Page 1 af 1
�
�
I
�
OS-26-21-0080-00600-0420 � Pasco County Property Appraiser Page 1 of 1 l
Data Current as Of: Weekly Archive - Saturday, December 30, 2017
Parcel ID 05-26-21-0080-00600-0420 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
DR HORTON INC Ag Land $0
12602 TELECOM DR Land $4,544
TEMPLE TERRACE FL 33637-0935 Building $0
Physical Address Extra Features $0
6693 WAGON TRAIL STREET
ZEPHYRHILLS, FL 33541
7ust Value $4,544
Legal Description (First 4 Lines) Assessed (Non-school Amendment i) $4,544
See Plat for this
Subdivision Taxable Value $4,544
SILVERADO RANCH SUBDIVISION
PHASES 6, 8 &9A PB 75 PG 075
BLOCK 6
LOT 42
Jurisdiction
City of Zephyrhills
Land Deta�il (Card: 001 of 001)
Line Use Description2oning jUn�ts _ �Type _;Price ;Condition Nalue
_____�_. �_ . f__ __�__..______ ' � �
1 i 0100 SFR� MPUD 6,000.00 SF G 0.75 � 1.00 j_ $4,500
2 � ; 0100 �� SFR � MPUD 176.00 M SF �� $0.25 i 1.00`! $44
Additional Land Information
___ _�.�_�_..___._ ���_�__��_�.____.__ _____
' Acres T 0.14 �Tax Area 30SI � FEMA � __ ( Residential Code SLVRLPI
' j � � I Code � ; �----
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
__� ____ Extra Features (Card: 001 of 001)
-�---------.----- -_i_. __._�_._�--,---__�._. —�_�___-
LineT�____ _ �Description �_ � ear _ ,__�Units �______ ;Value
^ No Extra Features
Sales History- See All 6 sales
Previous Owner: DUNE FL LAND I SUB LLC
Month/Year;Book/Page �Type_ � ` ,DOR Code��Condition�Amount
12/2017 �9649 / 0964� � Warranty Deed � 05 ! Vacant �Multi-Parcel Sale
_�___�_._._�____�_._ � _._.______ - - -- — .�_.-- -
�-�_�____�
05/2017 i9535 / 0546 � Certificate of Title ' 05 Vacant Multi-Parcel Sale
_______._.__--�--- -..�__r__...------._�_� _._--_ — - -
il/2016 (9462 / 0384 iMineral Rights or Royalty Transfer 05 Vacant��Multi-Parcel Sale
� http://search.pascopa.com/parcel.aspx?parce1=2126050080006000420 1/3/2018
C����
� ' 66�9 agon Wheel St.
SQ. FEET PRICE
MAIN OR LIVING: 2,238 $ 112.65
OTHER AREA UNDER ROOF• - $ 91.00
OTHER: - $ -
VALUATION $ 252,110.70
FEE SHEET $ 944.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,042.88
' ELECTRICAL: $ 212.40
PLUMBING: $ 141.60
MECHANICAL: $ 99.12
SUB-TOTAL $ 1,496.00
RADON: $ 33.57
TOTAL $ 1,529.57
SEWER: $ 2,010.00 �
WATER: $ 641.00
IRRIGATION: $ -
TOTAL: $ 2,651.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL.
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 5,207.70
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00
99% $ 3,595.68
� 1% $ 36.32 i
TOTAL: $ h 4,485.54
�
S'13-780-OQ20 City of Zephyrhills Permifi Appiication F�c-813-780-0021
. Building Ciepartment
DateReceived ,�l;;�i;.��",7�a,(�'F'� s�.' d`" � G�°�'���
Phone Contact for Perrr�iYting
—rrrrrrr.r r (�
Owner's Nama �. � (`�;� cs r-� . � Owner Phone Number _ ��1�• C ��t1
�• >r-�,�.. 1 �
Owner's Address !��"�����'e�" 'ry" p'� ��~n^E°���� � �Qwner Phone Number
Fes Simple Titleholder Name , ��r�� '�._ i� Owner Phone Number ��---^ �
Fee Simple 7itieholder Address '
JOB ADDRESS `� C � { . ' ' �` r rr '. �?�"I LQT# -! �
r
su�oiv�sioN J`�� u�e_r'c. ,�tc.� PARCELID# '�/.?��-��-�'�C7�0�` `� �'PD-�E��IZC�
{467AlNED FROM PROPERTY TAX NOTlGE)
WORK PROPOSED �NEw CONSTR 8 ADD(AL7 � S1GN � 0 DEN{OLISH .
lNSTALL REPAIR
PROPOSED USE . 0''� SFR [� C{JMM � OTNER
TYPE OF GQNSTRUGTIC?N ��''� BLQCK � FRAME � STEEL �
DESCR(PT101V OF WOFIK Or`t��-'� ���.' .rr 1c;�a-rv�.� �, ��'S�i��.'►�� t3 �J�c� ����-�"-L --'�c�-"t-`.
BUILDlNG SlZE � � S4 FOOTAGE i / � � HEIGHT ���
TR� r-r'r-r-�-o-'r-�r-t�-A-[Tri"i"1-rt�t-r-s-r-�-��c�'r�'r-i-r^s�r-rit�r'r`r'r-t-9"'rP'v-aTa'"'a-e-'u-r-s�-a'-e'-e�a�
C�BU(LDING � X�� fb�j VA�UATION OF TOTAL CONSTRUGTION
� u�..��
�ELECTRfCAL $ AMP SEAVIGE 0 . PRO�RESS ENEFIGY ' � W.R.E.C.
������� .
�PLUMBING $ _ �'"�'}
• �'�._.J
�MECMANlCAL $ L� �,�� VALUATiON OF MECNANICAL INSTALiATION
�GAB �j R0C7FlNG Q SPEC(ALTY � QTNEA �
FINISHED FLOOR EL.EVA7(ONS t �{',l �� ,� FLOQD ZONE AREA �YES NO
� L�
-R--�-C�-�--6-i--6-i�-6•-i-6--F'A-�-a--E--�-�F-�G--8-C-8--G-�F-*-�--�;-F'-k--��'�-'a-�--�-+"^¢-�-7-�,-4-r.�.�,�,�,-�' `B-H�-o-ir-�-�-��€u�° °��.°aw'r-4-�-E-�@-''�'-
HUILDER � ''����__,!�`r GONIPANY �t � - ���•""'��`�'"� �J"''�
SIGNA7URE REGISTERED � Y/ N FEE GURAER Y/N
Address f���� /���'Ci�.�-7 � r" I�'r}� '�"'� Llcense# ���--��T�� �' � �
.�l.EC7RICIA(I ���„�;c,,...-,,..�''"�',�.-- � COMFANY ��?�"`l+�A�„��,�"� ,��"�!'�'�`--7��'A'� �
SIGNATUaE ---``` REGISTERED Y( N . FEE GURRER Y/N
Address 4�d..����=',0'°,0''�C� .�,� � �9� License# ��-�%�'�'����� �
y
PLUMBER �� COMPANY � f'` !' �li,i�.!` .��8.���,��'� �` ��'"�";�i�'d`� �
SlGNATURE ������� REGlSTERED Y( N FEE CURRE� Y/N '
Address �,����}t,��,�� Af��� �',�u�.+�� License# ��+� +�.�c.�����a`
MECHANICAL �� CdflBPANY )"'�`"����`�����'� ��°'� �; ,%''7'��'fi
S1GNA1`IJRE f,.+^" ���"'��'`�w��-„-^-�^^�-'---REGISTERED Y�/ N FEE CURREA Y/N �
Address �`e�,"'� ,l.�Gf%t�.�- �� ,��a.,��',�,,,tf,,L.'',f`�-���. License# �������fi�:k� � �
..
�--., r
OTHEa ,/�_,,r,..-�.Y----. COMPANY �A<�,l� ��f':,�i�ta��.�� :�'�;����-�
SIGNATURE � �'�"'`�"" �
REGISTERED Y/ N FEE CURREA Y(N /'�
A,ddress �����`� '�a� - ��� �'���� License# �— �
liliMitlllTiI111111l11 ! ! ! lllltit1ii11fili61MllilIY1IH1119 ➢ fl1H188bl6 !
RESlDEN71AL Attach{2) Pfat Pians; (2)sets of BuilBing Plans; (1)set of Energy Forms; R-0-W Permit for new construction,
Miniriium ten(10)working days after submittai date. Required onsite,Construction P(ans,Stormwater Plans w/Silt Fence installed,
Sanitary�acilities&1 dumpster;Site Work�Permif for subdivisions!large proJects
COMMERCtAL Attach (2)complete sefs of Building Pians plus a Life Safety Page; (1)set of Energy Forms.R-O-W Permit for new constructlon.
Minimum ten(10)warking days a�ter submitta(date. Required onsite,Construction Plans,Starmwater Plens w(Silt Fence instatted,
' Saniiary Facitities&1 dumpster.Site Work Permit for ai!new projeets.Ai!commerciai requirements must meet compliance -
SIGN RERMIT Attach {2)sets of Engineered Plans. -�
"`*"*PROPERTY•SURVEY required for alI NEW cqnstruction.
-i-.i-.6.-d-.i_�-6-.,i._i.-I-i-�-.i-.1:-1-�-.I�C..�..b�1-d-.1_.i-.8-�1�-a-.�-E.-i-i�-B--E-S..B-�B.-i-�.b�.�-0--6-a-8-�6�-d-6-8-�.b.$-�&,-9-E;9.Qfl.di..9..i-.8•�-6.-¢�8-4..8�.
d{T8CtI0ii9;
FiII out application completely.
Qwner�Contractor sign back of application,notarized
It over$250Q,a Notice of Gommencement is reqvired. (AjC upgrades over$7500) _ -
** Agent{for the contractor)or Ppwer of Attorney(for the awner)wou(d be someone with notarized letter fram owner authorizing same
OVER THE COUNTER PERMl7TING (copy of contract required} -
Fleroafs•if shingles Sewers Service Upgrades A/C Fences{P(at/5unrey(Faatage) , _ -, • ~� ,
Driveways-Not over Gounter if on�ublic roadways..needs ROW , ' ' ' ,_ „ , �
, v ._ • .. „ �
. � - - - . - � - � �
f - _
�dOTtCE t�F �}��� FtESTRi�TtOi�S: The undersigned understands fihat this permit may be subject to "deed" restrictions"�
which may he more rsstrictive than County regulations. The undersigned assumes responsibility for campliance with any
' applicable deed restrictions.
UNLICENSED COfVYRAC70RS AND CONTRACTOR RESPONSIBlL.lTlES: !f the owner has hired a contractar or
cantractors to undertake work, they may be required to be licensed in accordance with state and laca! regulations. !f the
contractar is not�(icensed as required by (aw, both the owner and contractor may be cited for a misdemeanor violation
under state law. Ef the owr�er or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the f'asco County Builciing [nspectit�n Division—Licensing Sectian at 727-847-
8Q09. Furthermore, if the owner has hired a cantractar or cantractars, he is advised to have the contractor(s} sigrt
portians of the "contractor Block" of this applicatian for which they will be responsible. !f you, as the owner sign as the
cantractor, that may be an indicatian that he is not properly licensed and is not entitled to permitting privileges�in Pasco
Caunty. '
TRANSFORTAT'tOR! IIi�PACT/UTILtTtES tMPACT AND RESOURCE RECaVERY FEES: The undersigned.understands
that 7ransportation lmpact Fees and Recourse Recovery Fees may apply to the canstruction af new buildings, change of
u�e in existing buildings, or expansion of existing bui{dings, as specified in Pasco County Qrdinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identifisd at the time of
permitting. lt is further�understood that Transportation Impact Fees and Resaurce Recovery Fees must be paid priar ta
receiving a "certificate of occupancy" ar final pawer release. If the project does not invoive a certificate of occupancy or
final power refease, the fees must be paid prior ta permit issuance. Furthermore, ifi Pasco�Caunty WaterJSewer lmpact
fees are due,they must be paid pripr to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCT90N LIE6d LAW (Ch�pter 713, Florida Statutes, as amended}: !f valuation of v�ork is$2,500.Q0 or more, 1
certify that I, the applicant, have been provided with a copy af the "Florida Construction• Lien Law—Homeowner's
Pro#ection Guide" prepared by the Flarida Department of Agriculture.and Consumer Affairs. If the applicant is someone
ather than the"awner", i cerEify that ( have obtained a copy of the abave described document and promise in goad faith ta
deliver it to the"owne�" priar to ccammencement.
CONTRACTOR'S!O!!11lNER'S AFFlDAV1T: I certif}r that al! the informa#ion in this application is accurate and that all work
will be done in compliance with all applicable laws regulating canstruction, zaning and land develapment. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
canstruction, County and City cades, zanfng regulatians, and land deveCopment regulations in the jurisdiction. i also
certify that ! understand that the reguiations of other govemment agencies may apply to the intended warK, and that it is
my respansibifity to identify what actions ! must take to be in compliance. Such agencies include but are nat limited to:
- Department of Environmenta! Protection-Cypress Bayheads, Wet(and Areas and Environmenta!!y SensitiVe
Lands,Water/Wastewater Treatment.
- Southwest �(orida Water Management District-We(Is, Cypress Bayheads, Wetland Areas, Altering
Watercaurses. .
- Army Carps afi Engineers-Seawalls, C►oc4cs, Navigable Waterways. '
, - Department of Hea(th & Rehabilitative Setvices/Envirorimental Fiealth Unit-Welis, Wastewater Treatrnent,
Septic fianks. �
- US�Environmental Protection Agency-Asbestos abatement.
- Federai Aviation Autharity-Runways.
1 understand that the fa(lawing restrictions apply ta the use of fiil:
- Use of fi!! is not aflowed in Flood Zone"V" unfess expressly permitted.
- If the fill material is to be used in F(ood Zone "A", it is understaod that a drainage .plan addressing a
� "comp"ensating volume" will be submitted at time of permitting which is prepared by a professiana! engineer
licensed by the State of Florida.
- If the �11 material is to be used in Flood Zone "A" in connection with a permitted buiiding using stem wall
canstruction, 1 certify that fill wili be used o�ly to fili the area within the stem wal1.
- !f fill material is to be 'used in any area, ( cerCify that use of sUch fill wi{i not aduersely affect adjacent
properties. If use af fil! is faund ta adversely affect ad'}acent proparties, the owner may be cited for vio{ating
the conditions af the building permit issued under the attached permit application, for lots less than one (1}
acre which are e(evated by fill, an engineered drainage plan is required. .
if f am the AGEN�' FOR TNE CtV1li�ER, i promise in good faith ta inform the owner of the permitting conditions set forth in
this affidavrt prior ta commencing construction. 1 understand that a separate permit may be.required for electrical work,
: plumbing, signs, wells, pools, air conditioning, gas, or ather installations not specificaHy incEuded in the application. A
permit issued shall be constru�d to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical cades, nor shall issuance of a permit prevent the Building Ofificia!frQm thereafker
requiring a correction ofi errors m plans, construction or vialations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, ar if work authorized by
the permit is suspended or abandoned fbr a period;of six (6} mon#hs after t3�e time the work is commenced. An extension
may be requested, in writing, from the Building Oificia! for a period not to exceed ninety (90) days and wilE demonstrate
� justifiable cause for the extension. If work ceases far ninety (90) consecutive days,the job is cansidered abandanetl.
WARNt�fG 'T� OWt�ER: �tOUR �AILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYl�IG 7WICE FOf� IMPROVEMENTS 1"O YOUR PRdPERTY. tF YOU 1NTEND TO OBTAIN FiNANC1NG, CON$ULT
W17H.YOUR L�NQER C?R AN ATTORNEY BEFpRE RECURDING YOUR fitOT10E{3F CCIMMENCEMENT.
FLORIDA JURAT(F.S. 1 y 7.03) � �
OWNER OFi AGENT �—�'"` ~ CONTRACTdR
Su�jjcr�b���nd swc�n to (or a irmed)before me this Subscribed and sworn to(or affirmed)before me th'ts
1�ld.i�c�l�=..hy ,ll�.�.-✓t•fl��.'-{�,�r.:�e..:.Z�,c,'i.L�t bY
. Wfio is/are aersonally known to me or has(have produced Who is/are personaliy known to me pr hasmave produced
as identification. as identitication, �
�_;��(��� •`�"' Notary Rublie Notary Public
r' , ,,
' Commission Na. r Gommission No.
' Name of Natary typed,printed or stamped Name of Notary typed,printed or stamped
P� Nofary Public State af Flarida
� �; M(cheUe Moyes
'� My Comm3sslan�G o57321
�� p� Explreb'12/21l2020
I n�
Single Family Dwelling
Plan Review Comments
1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan.
2. Lots shall be graded to comply with R401.3 of the F.B.C.
3. Compaction test required if 24" or more of fill dirt is brought in at any one place.
4. Tie in survey required before pouring concrete.
5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have
expansion material.
6. All setbacks shall be met.
7. All property markers shall be uncovered and marked at time of first inspection.
8. All A.D.A. requirements shall be met.
9. No electric,plumbing,mechanical, or framing shall be covered without an inspection and
approval first.
10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).
11. Appliances shall not be installed in a location where subject to mechanical damage unless
protected by approved barriers. M303.4 of the F.B.0
12. Water heaters shall comply with section P607.3 of the F.B.C.
13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1
14. Return air in all bedrooms. F.B.C. M1620.4
15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C.
16. All glazing requirements are to be in accordance with R308.4 of the F.B.C.
17. All means of egress are to be in accordance with R311 of the F.B.C.
18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C.
19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker.
20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating
or appliances or an attached garage. They shall be installed in accordance with the F.B.C.
21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all
underground plumbing and electric.
22. A112008 N.E.C. Codes will be enforced.
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0
24. In accordance with the Land Development Code, lots shall be sodded before final at least 10
feet around the structure.
25.A copv of the energv cacls shall be with pernzit at all times.
26. Copy of final insulation report shall be provided with per�nit before fina�
F.F.E.-Finished Floor Elevation
F.B.C-Florida Building Code Sth Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008)
PLOT PLAN
. DESCRIPTION:(AS FURNISHED) .
LOT 42, BLOCK 6 SILVERADO RANCH SUBDIVISION PHASE 6, 8 & 9A
NOT YET RECORDED IN PLAT BOOK ----, PAGE(S) ----, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. I
LOT 45 � LOT 44
BLOCK 6 � BLOCK 6
� S87'24'28"E
� .35.65' C1 —
Z '�9� LOT 42 ,,
BLOCK 6 a°
� �.. _ 30' ti>.
GRAPHIC SCALE 5 ;, 6,n6 sq. FT t j »6.0
�r„ — — �� �
O 1 S 3O I DRAINAGE TPE A '� I�
8.2' I
COVERED.0 26.7• 8.2'
� I IANAI . � �.r�
N 120., I � ,
I 38.67' I � .
LOT 41 � I
BLOCK 6 PeoPoseo LOT 43
W I ^ ARIA-1672 n ^ I �j BLOCK 6
� ON LOT CALCULATIONS ' a 4EAB— D � ^
LOT = 6,176 SQ. FT. N FlNISHED FLOOR � �
� LIVING AREA = 1,672 SQ. FT. � I ELEVA710N=11g,2p `�I N a
GARAGE = 432 SQ. FT. a� ��
ENTRY = 38 SQ. FT. � I �� ,
LANAI = 96 SQ. FT. �1 COVERED N?
PAT10 = 0 S�. FT. O I i�4' ENTRY p
DRIVEWAY = 370 SQ. FT. Z ^ `:� I �
A/C PAD = 12 SQ. FT. 8.2. 17.0'2. ' ': ' 2.0'19.3' -
� WALKWAY = 28 SQ. FT. — ' — - -- . es'
IMPERVIOUS • = 43% II o "`�6.0' ''
= 2648 SQ. FT. "'o.';•:;;-;.:.: �
SOD = 3,528 SQ. FT. `lY � �n ,`;bRIVE'.. ' N
OFFLOTCALCULATIONS �! —N ---N---�� �," M
S,S _N—_
DRIVE APRONY = 247� S0. FT. _ _ _ � �o' UE _ ,`a.yr.
PUBLIC S/W = 275 SQ. FT. �. ...,.... .�+,`;.,.�'� ,�`
SOD = 468 SQ. FT. ��'N .�.. .4;'. :'-.W.:�.� :�. �• ... ——
TOTALS .. •-'' �
AREA = 7,166 SQ. FT. - �w
DRIVEWAY = 617 SQ. FT. , ��o
SIDEWALK = 303 SQ. FT. �n o
SOD = 3,996 SQ. FT. Z�'
` ��p� ' CENTERLINE OF � 6.25�
— — _ 80.30' RIGHT—OF—Wqy� — I PT _
� N87'24'28'W — �L
(REFERENCE BEARING) 86.55'
WAGON TRAIL STREET
TRACT "G" — 60' RIGHT OF WqY
(PRIVATE ROADWAY)
PREPARED FOR:
D•R•HORI1f)1V'N„
t��'�ccs'-�'iut'l e c�rva robia
Curva�/ Length Radius Delta Chord Bearing Chord
, BUILDING SETBACKS C1 19.39' 200.OD' S33'14' N69'48'S5'E 19.36' II
FRONT: 22'
REAR: 15' �
SIDE: 7.5'
SIDE STREET: 20' LEGEND:
NOTES: - - - BUILDING SETBACK LINE PI POINT OF INTERSECTION
PC POINT OF CURVATURE
t. ELEVATIONS SHOWN ARE PER LOT GRADING --- CEN1ERUNE PT POINT OF TANGENCY
PLANS PROVIDED BY THE CLIENT. -- - - RIGHT OF WAY UNE RP RADIUS POINT
2. ELEVATIONS ARE BASED ON NAVD 1988 XX PRC POINT OF REVERSE CURVA7URE
DATUM. ' � PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE
TYP TYPICAL
� PROPOSED DRAINAGE FLOW CS CONCRETE SLAB
THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES � CONCRETE �C� PER PLAi
ONLY THIS IS NOT INTENDED FOR THE CONSTRUCTION OF cALcu�n�o
THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND A/c AIR CONDITIONER PB PLAT BOOK
OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/�'� SiDEwnuc PGS PAGES
SQ. FT. SQUARE FEET
LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.E.At.A. FEDERAL EMERGENCY MANAGEMENT AGENCY
AND IS FOR INFORMATIONAL PURPOSES ONLY. F.i.R.M. �oo� iNsuRaNCE Ra�MnP
NAVD NORTH AMERICAN VER7ICAL DATUM
THIS IS NOT A SURVEY D&UE DRAINAGE&UTILITY ASEMENT ATUM
THIS IS A PLOT PLAN ONLY ueE UTILIN EASEMENT(PUBLC)N7
FLOOD NOTE: SURVEYOR NOTES:
- 1 HAVE EXAMINED THE F.I.R.M. MAP N0. 12701CO288F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE
DATED SEP7EMBER 26, 2074, AND FOUND THE SUBJECT PROPER7Y LAND SHOWN HEREON FOR EASEMENTS, RIGHT
APPEARS TO L1E IN ZONE'%', AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH
0.2%ANNUAL CHANCE fLOODPLAIN. THE SURVEYOR 1AAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND.
GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE
�oca�F.E.M.n. ncENr FOR vERiFlcnnou. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN
LOCAiED EXCEPT AS SHOWN.
BEARING BASIS: '
6EARINGS SHOWN HEREON ARE BASED ON THE CENTER LINE OF WAGON 3. NOT VALID WITHOUT THE AUTHENTIC
TRAIL STREE7 BEING N87'24'28'W, PER PLA7. ELECTRONIC SIGNATURE AND THE AUTHENTIC
ELECTRONIC SEAL OF A FLORIDA LICENSED
REwsEo: A M E R 1 CA N SURVEYOR AND MAPPER.
(FIELD DATE:) ��
S�A�E. S U R V E Y 1 N G ��!w y. � Dlgitallysigned byJames W Boteman
1�= 3D FEET ' '.'oN:cn=JamesWeoleman,
S� MAPPING INC. vf�"`���'�'` �
�i= o=American5urveying&Mappinry
APPROVED BY' �B ��� •• �-^�—e�'
CERTIFlCATION OF AUi}iORIZATION NUMBER LB�6393 ��,�:�; . ,ma�I=)boleman�asmcorpoatecomFOR
3191 MAGUIRE BOULEVARD, SUITE 200 ,c=us ��
171013 LOT 42, BLK 6 ,•�"'�%^r''�� Date:1017.102710:1445-04'00' TME
JOB No. ORLANDO, FLORIDA 32803 , FlRu
� (407) 426-7979 DATE
DRAWNBY: DSB pLOT PLAN 10-25-2017 JML �w•AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485
5335 - 8TH STREET �
(813)780-0020
CERTIFICATE OF OCCUPANCY ,
Address: 6693 WAGON TRAIL ST Owner: DR HORTON INC '
ZEPHYRHILLS, FL. 12602 TELECOM DR
Subdiv: SILVERADO TEMPLE TERRACE FL 33637-0935
Parcel: 05-26-21-0080-00600-0420 Work Type: 101-NEW CONST/SFR -
Construction Type: NOT APPLICABLE � Sprinklers
Use Classification: NOT APPLICABLE
Permit Number: 19189 �
Date• 5/17/2018
�e,(,i� ��-
� ISS D BY: BUILDI OFFICIAL :
WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE
GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE
I '