HomeMy WebLinkAbout18-19244 .-\
CITY OF ZEPHYRHILLS
5335-8TH STREET
� „ % (sispso-oo20 1 44
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
II - PERMIT INFORMATION � � LOCATiON INFORMATION '
Permit#:19244 Issued: 1/31/2018 Address: 3221 MOULDEN HOLLOW DR
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 267,205.80 Total Fees: 14,510.47 Subdivision: HIDDEN RIVER
Amount Paid: 14,510.47 Date Paid: 1/31/2018 Parcel Number: 24-26-21-0090-00000-0340
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W. CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA FL 33607
Phone: (813)574-5743 Lic: Phone: 813-574-5700
Work Desc: CONSTRUCT SINGLE FAMILY 2,372 SQ FT
APPLICATION FEES
B ILDING FEE 1,082.65 ELECTRICAL FEE 221.18 PLUMBING FEE 147 45
MECHANICAL FEE 103.22 SEWER CONNECTION RESIDEN" 2,010.00 WATER CONNECTION RESIDENI 641.00
WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00
SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
I � '
�
�
� x ✓ �--1�
����
� �
�
Ins ections Re ui " -
FOOTER 2ND ROUGH PLUMB MIS INSULATION CE LING I
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME � MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this properly that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
' Complete Plans, Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
�✓
CONTRACTORS SIG ATURE PERMIT OFFI
PERMIT E PIRES IN 6 MANTHS WITHOUT APPROVED INSPECTIO '
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
i
_ . � IIIIIIIIIIIIIIIIIIIIII�IIIiIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
, � •� ' 2018017430
Rcpt:1928242 Rec: 10.00
DS: 0.00 IT: 0.00
01/31/2018 K. A. , Dpty Clerk
PAULR S 0'NEIL,Ph D PASCO CLERK & COMPTROLLER
01/31/2018 11:18am 1 of�y1
I --OR_BK ���1 P� Z�J��
Permit No. �� Parcel ID No 24-26-21-0060-00000-0340
NOTICE OF COMMENCEMENT
State of Florida County of PaSCO
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713, Florida Statutes,
the following information is provided in this Notice of Commencement:
1. Description of Property: Legal HIDDEN RIVER PHASE ONE A PB 74 PG 101 LOT 34
streetAddress: 3221 Moulden Hollow D►'ive Zephryhills FL 33541
2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence
3. Owner Information: Lennar Homes, LLC
Name �
� 4600 W Cypress St. Ste 200 Tampa FL, 33607
Address City State
Interest in Property:
Name of Fee Simple Titleholder: N�A '
(If other than owner)
Address City State I
a. contractor� Lennar Homes, LLC
Name
4600 W Cypress St, Ste 200 Tampa FL, 33607
Address City , State
Contractor's Telephone No.. 813.574.5700
5. Surety: - N/A
Name .
Address City State
Amount of Bond: $ ' Telephone No..
6. Lender: N�A
Name '
Address City State
Lender's Telephone No..
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7),Florida Statutes:
_ Lennar Homes LLC '
Name
� 4600 W Cvpress St, Ste 200 Tampa FL, 33607
Address City State •
Telephone Number of Designated Person: 813.574 5700
8. In addition to himself,the owner designates N/A of
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner
9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified:
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
' RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATfORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
I STATE OF FLORIDA ��
CQUNTY OF PINELLAS
Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager
Vice President
Signatory's Title/Office
The foregoing instrument was acknowledged before me this 3 day of March c�0 I 7 �by
Steve Robert Smith as Vice President (type of authority,e.g.,officer,trustee,attorney in fact)for
Lennar Homes, LLC (name of party o a f of who ' t ment was executed).
Persohally Known:�,OR Produced Identification❑ Notary gnatur
Type of Identification Produced Name(Print) Eli olleran
Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in
if are true to the besYof my knowledge and belief.
; II,, � -
;.��'3'�t►1"�,.ELISSAM.NOLLERAN �Ig�of Natural�on Signing Above
a
;�; ;M Gmml�slon�FF 88583T
�o'=Ex'Iree June 6,2020 �
, wpdata/bcs/bcs form; •�P�� '° dondorThm7ror_Folnln+unna100�3i5-
7010
� . .
���� : ��'�� STATE 0� FLat�tDA,��U�+TY OF PA�.�
THIS IS 70 C�RT��'Y 7HA��'HE FOREGOING IS A
�°�� � .D�� TRUE AND CORF3EC�'COPY OF 7HE DOCUMENT
� ';' ' ON FILE OR OF f'UBLIC f2 CORD IN THIS OFFICE
� ' ""�' � '• � WITNESS MY HAND AND FICIAL SEAL THcI'S��
�ust � 2.
� � ��t�on'w9 f e��,. � ��DAY OF -
_, � � ' � , � � PAULA S.O'NEIL,CLE &COMPTROLLER
� -4 ���:��87 BY (il ' � - DEPUTY CLERK
� .,. ..,.. � o ����� '
°���'����'
, �� ; 3221 Moulden Hollow Dr-2,372 sq ft-Lennar Homes
o umn
SQ. FEET PRICE
MAIN OR LIVING: 2,372 $ 112.65
OTHER AREA UNDER ROOF: - $ -
OTHER: - $ _
VALUATION $ 267,205.80
FEE SHEET $ 983.00
ADDRESS $ 40.00
� DRIVEWAY $ 40.00
BUILDING: $ 1,082.66 �pS
ELECTRICAL: $ 221.18
PLUMBING: $ 147.45
MECHANICAL: $ 103.22
SUB-TOTAL $ 1,554.50
TOTAL $ 1,554.50
SEWER: $ 2,010.00
WATER: $ 641.00
IRRIGATION: $ -
TOTAL: $ 2,651.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: $ -
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00 �
5% $ 26.35
TOTAL: $ 553.35
, S U B-TOTAL $ 5,232.63
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00
100.0% $ 4,828.00
� � 1.0% $ 48.28
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 14,510.47
s�s-7so-oa2o City of Zephyrhi[Is Permit Application ��X-s�s-7aa-oo2�
� + � Building Department
Date Received phone Contact for Permittlng 813 363 __ 2891
1 1 1 1 1 t 1 1 1 ! I .d 1
-Owner's Name Lennar Hornes,LLC Owner Phone Number 813.574.5700
Owner's Address `�6Q0 W.Cypress St.Ste.204,Tampa,FI.33607 pwner Phane Number � �
Fee Simple Titlehotder NaErte N�A'' � Owner Phone Number �` �
Fee Slmple 7it[eholder Address N/A
JOB ADDRESS ��21 Moulden Hollow Drive LOT# 0340
SUBDIVISION Hidden River Phase One A pqRCEL ID# �4-26-21-OQ60-00000-0340
{087AINED FROM PROPERTY TAX N0110E}
WdRK PROPOSED II�/ I� NEW CONSTR 8 ADD/ALT � SIGN � � DEMOLISH
� INSTALL REPAIR
PROPOSED USE � SFR � COMM � OTHER
TYPE OF CONSTRUCTION � BLOCK Q FRAME � STEEL 0
DESCRIPTION OF WORK Single FamIly ltesidence/Paol/Screen Enclosure/Fence
BUILDING SIZE U/R SF ���� SQ FOOTAGE �93� HEIC�HT 1 Story�
�BUILDING � I..ry7 �a Q VALUATION OF TOTAL CONSTRUCTION
/
���/ �ELECTR(CAL �� � PROGRESS ENERGY Q W.R.E.C.
� � AMP SERVICE
f�PLUiU1BING �;�� r�
� ����
�MEGNANICA� $ VALUATION OF MECHAhl3CAL INSTALLATION (�
�
QGAS � ROflFING Q SPEC(A�TY � OTHER
FINISHED FLOOR ELEVATIONS � � FLOOp ZONE AREA �YES nV0
L_1
_,_� . � . ■_ ,
BWLDER � � CQMPANY Lennar Homes,ZLC
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address 4600 W.Cypzess St.Sfie. 0,Tampa,FL 33507 License# CGC1518166 �
EGEGTRIGlAN COMPANY Edmonsan Electric, Inc.
SIGNATUFtE REOISTERED Y/ N FEE CURRE� Y/N
Address ��34 Skippet Road,Ta pa, FL 33613 License# EC13p05408 '��
PLUMBEt2 GOMPANY Bayonet Plumbing, Heating &AC, 1nc
SIGNATURE REGISTEREp Y/ N FEE CURRE� Y/N
Address Q.Q. �ax 530$, Bayonet, �3�674-53Q8 �icense# CFC04299$ �
MEGftANICAL � con��a�aY Bayonet Piumb�ng, Heating &AC, lnc
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address �'•fl� �flx 53Q8, Bayottet, F 3467�€-53Q$ �icense# GAC058062 �
OTHER COMPANY
SiGNATUi2E REG�STEREp Y/ N FEE CURRE� Y/N
Address �211 Shoa! L.ine Blvd, Spt'i Hill, FL 346Q7 �icense# ��CQ5799`I �
IIIIIIIIIIIM11111111111 1111111111111111111111111111110111111111111
RE8IDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans,(1)set of Energy Forms;R-O-W Permit for new canstruction,
Minimum ten{10}worKing days after submitta!date. Requared onsite,Construction Pians,Stormwafer Plans wJ Si(t Fence installed, i
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERClAL Attach(2�complete sets of Building Plans plus a Life Safety Page;(1}set of Energy Forms.R-O-W Permlt for nsw consUucfion.
Nl'tnimum fen{14}working days after su6miftal date. Required onsite,Construction Plans,Stormwafer P(ans w/Siif Fence instailsd,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet oompliance
SIGN PERMIT Attach{2)sets af Engineered Plans.
*�"*PROPERTY SURVEY required far aIi NEW construction.
.-�_1-� • • • • • Y • • /. � • • Y • • •....� • • • • • • • • • � � • • �..• • •.. • • • • • • Y L•
Dlrectlons:
Fil1 out applicaf'son�comp(etely.
Owner&Contractor sign back of application,notarized
tf over$2500,a Notice of Commencement is required. {A(C upgrades ouer$750Q}
"'* Agen#(for the contracfor)or Power of Attorney(for the owner)would be someane with notarized letter from owner authorizing same
OVER THE GOUN7ER PERN!lTTtNG (copy of contract required) _
Reroofs if shingles Sewers Service Upgrades A/C Fences(PIof/SurveylFootage}
Driveways-Nat over Counter 3f on gubiic roadways..needs ftOW
J
�—
�lOTICE OF DEED RESTRICTIONS. The undersigned understands that this permit may be subject to"deed"�estrictions" �
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009 Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "cerfiificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to �ermit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
COiVSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
COfVTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Vllastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks. ,
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone"V" unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building O�cial from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMEfVCEMENT MAY RESULT IN YOUR
PAYIIdG TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND YO OBTAIN FINANCING, COIVSULT
WITH YOUR LEfVDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S. 117.03)
OWPJER OR AGENT CONTRACTOR
Subscribed and sworn to(or affirmed)befo e me this Subscribed and sworn to(or affirmed) fore me this
u3-ivov-i� bY paul Sweene 03-Nov-17 by Paul Sweene
Who is/are personally known to me or Who is/are personally known to me -�asN�ave-predaeed�
tification. as identification.
Notary Public Notary Public
Commission No. FF98537 Commission No. FF98537
Elissa M.Holleran Elissa M.Holleran
Name of Notarv tvped,printed or stamped Name of Notary typed,printed or stamped _
..� �9,19�14W.p1�9�RE�W' - + _ &�,1��4'N.91P�L�4�NNW� —
�� �Rrn�'aniup�ul�e9T ' j�e�r�n'�a3am�PPu�aa4�
i��a+�,�c�����d�d
liElp�',9�1,(Iltxi�����G�O � �+d�Il1N?�F�4e4a��941�i�9�Sy1PII �
'! .�� B3�d�d'6bN't7eXFi7tl�Sllpy45ili#�Y9�I�t .
ri
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1941A sf ADS Builder Name: Lennar Homes
street: 3221 Moulden Hollow Drive Permit Office: Cl of Zephyrhills
City,State,Zip: ,FL, Permit Number �,�Z�C{� ,
Owner. �ennar Homes ,lurisdiction: 611600 � I
Design Location: FL,Tampa County• Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Euterior R=4.1 1454.60 ft2
b.Frame-Wood,Adjacent R=11.0 506.78 ftz
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 4 d.N/A R= ftZ
10.Ceiling Types (1936.0 sqft.) Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1936.00 ft2
6. Conditioned floor area above grade(ftz) 1936 b.N/A R= ftZ
z
Conditioned floor area below grade(ftZ) 0 11 cDucts R R ft2
7. Windows(157.3 sqft.) Description Area a.Sup:Attic, Ret:family rm,AH:laundry rm 6 387.2
a. U-Factor Dbl,U=0.54 101.00 ftZ
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 33.33 ft= �2•Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00
c. U-Factor: Dbl, U=0.56 23.00 ftZ
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N!A ftz a.Electric Heat Pump 32.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.212 ft.
Area Weighted Average SHGC: 0.308 14.Hot water systems
8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF 0.950
a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft� b. Conservation features
b.N/A R= ftz None
c.N/A R= ftZ 15.Credits Pstat
Total Proposed Modified Loads: 61 81 pASS
Glass/Floor Area. 0.081 Total Baseline Loads: 62.65
I hereby certify that the plans and specifications covered by Review of the plans and ' D�eT�5TA?, •-
this calculation are in compliance with the Florida Energy specifications covered by,this � "a_•� '�p
��y ii,; k-r?`., .1{!.. �
Code. � � calculation indicates compliance �'��,,, � ,= �.��.s+
�aVe ���C� with the Florida Energy Code. !. rrnr�°�%-:.:;-t'��-;;:�`•��,�O�
a:;..�:.... �.
PREPARED BY: Before construction is completed f '' �.
DATE. this building will be inspected for � -I�'�����'- -" �
compliance with Section 553.908 *.. `•`��'. :- -�
I hereby certify that this building,as designed, is in compliance Florida Statutes. ,� •
with the Florida Energy Code. �G'Oj3 ���
W�<..
OWNER/AGENT' BUILDING FFICIAL. �
DATE: � DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory�sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house.
8/7l2017 2:03 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1941A sf ADS Builder Name: Lennar Homes
street: 3221 Moulden Hollow Drive Permit office: City of Zephyrhills
City,State,Zip: ,FL, Permit Number�
Owner Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area
2. Single family or multiple family • Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ftz
b.Frame-Wood,Adjacent R=11.0 506.78 ft2
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 4 d.N/A R= �:
5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area Z
a.UnderAttic(Vented) R=30.0 1936.00 ft
6. Conditioned floor area above grade(ftz) 1936 b.N/A R= ftZ
Conditioned floor area below grade(ftz) 0 c.N/A R= ftz
11.Ducts R ft2
7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2
a. U-Factor: Dbl,U=0.54 101.00 ftZ
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 33.33 ft2 �2•Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00
c. U-Factor: Dbl,U=0.56 23.00 ftZ
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A � ft� a.Electric Heat Pump 32.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.212 ft.
Area Weighted Average SHGC: 0.308 14.Hot water systems
a.Electric Cap:40 gallons
8. Floor Types (1936.0 sqft.) Insulation Area EF 0.950
a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftZ b. Conservation features
b.N/A R= ft2 None
c.N/A R= ftZ 15.Credits Pstat
Total Proposed Modified Loads: 61.81 pASS
GlasslFloor Area: 0.081
Total Baseline Loads: 62.65
I hereby certify that the plans and specifications covered by Review of the plans and �T�S�'.q?.. -._
this calculation are in compliance with the Florida Energy specifications covered by this ���'a� r�R,;�O�
Code. calculation indicates compliance w'�„�'';� _;-'.��:�.�s+.
�ave ���C� with the Florida Ener � Code. ti »�rr �� �` �"�� `�a�Q ,
9Y `�`'�- ��� �
PREPARED BY: Before construction is completed :� �-- ''�r ""� "' -•
DATE. this building will be inspected for �' :`���i ° �
compliance with Section 553.908 ' * � '�� : •:�
I hereby certify that this building,as designed, is in compliance Florida Statutes. =1,� : •4
with the Florida Energy Code. COD�q��'���
OWNER/AGENT' BUILDING OF.FI AL: ' �
DATE. DATE: '' "
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory�ealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house.
8R/2017 2:03 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6
f �
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1941A sf ADS Builder Name: Lennar Homes
street: 3221 Moulden Hollow Drive Perm�t o�ice: City of Zephyrhills
City,State,Zip: ,FL, Permit Number•
Owner Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ftz
b.Frame-Wood,Adjacent R=11.0 506.78 ft2
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedroams 4 d.N/A R= �:
5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area =
a.Under Attic(Vented) R=30.0 1936.00 ft
6. Conditioned floor area above grade(ftZ) 1936 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ
11.Ducts R ftZ
7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2
a. U-Factor: Dbl,U=0.54 101.00 ftZ
SHGC: SHGC=0.31
b. U-Factor: Dbl, U=0.56 33.33 ftZ 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00
c. U-Factor: Dbl,U=0.56 23.00 ftz
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.212 ft.
Area Weighted Average SHGC: 0.308 14.Hot water systems
8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF'0.950
a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftz b. Conservation features
b.N/A R= ftZ None
c.N/A R= ffZ 15.Credits Pstat
Glass/Floor Area: 0.081 Total Proposed Modified Loads: 61.81 pASS
Total Baseline Loads: 62.65
I hereby certify that the plans and specifications covered by Review of the plans and ' . �.'Ck1E.s�.q�,, -._
o -- _..^ �,�_.
this calculation are in compliance with the Florida Energy specifications covered by this ` ,�' _.�_ O
Code. calculation indicates compliance ��;,,�''' `"�'-���.��.�s+-
t+s _�� , :.,:��..�„ ±�'
/, with the Florida Energy Code. F+ .r�rrr.�i'�%;-:;f.�.,,y,��„ � .
PREPARED BY: �aVe �����'c Before construction is completed '� _ ��� ' '� �" �
- DATE. this building will be inspected for � -1�,���'� - . �.
compliance with Section 553.908 *., �� � �
I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. �-
Y fY 9� 9 P '� 5- -
with the Florida Energy Code. - �OD"y�'��.= -� ,
OWNER/AGENT: BUILDING Q�FICI�9L:
DATE. DATE: � /�Jt�'f
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house.
8/7/2017 2:03 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 �
� .
FORM R405-2014
PROJECT
Title: 1941A sf ADS Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1936 Lot#
Owner. Lennar Homes Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Lennar Homes Rotate Angle: 45 Street:
Permit Office: Cross Ventilation: No County: Pasco
Jurisdiction: Whole House Fan: No City,State,Zip: ,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
� IECC Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium
BLOCKS �
Number Name Area Volume
1 Entire House 1936 16360.3
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated
1 master 210 1680 No 2 1 1 Yes Yes Yes
2 family rm 341 3171.3 No 0 1 Yes Yes Yes
3 cafe 161 1288 No 0 1 Yes Yes Yes
4 kit 182 1692.6 Yes 0 1 Yes Yes Yes
5 bdrm2 147 1176 No 1 1 1 Yes Yes Yes
6 bdrm3 149 1192 No 1 1 1 Yes Yes Yes
7 bath2 61 488 No 0 1 Yes Yes Yes
S bdrm4 149 1192 No 1 1 1 Yes Yes Yes
9 o wic 104 832 No 0 1 Yes Yes Yes
10 privy 24 192 No 0 1 Yes Yes Yes
11 o bath 117 936 No 0 1 Yes Yes Yes
12 laundry rm 100 800 No 0 1 Yes Yes Yes
13 foyer 148 1376.4 No 0 1 Yes Yes Yes
14 hall 43 344 No 0 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio master 29.5 ft 0 212.3 ft2 � 0 0 1
2 Slab-On-Grade Edge Insulatio family rm 14.5 ft 0 340.8 ft2 — 0 0 1
3 Slab-On-Grade Edge Insulatio cafe 25.5 ft 0 161 ft2 —� 0 0 1
4 Slab-On-Grade Edge Insulatio kit 13.5 ft 0 182.3 ft� ___ 1 0 0
8R/2017 2:03 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2014
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
5 Slab-On-Grade Edge Insulatio bdrm2 10.5 ft 0 146.8 ft2 —__ 0 0 1
6 Slab-On-Grade Edge Insulatio bdrm3 13.5 ft 0 148.5 ft2 � 0 0 1
7 Slab-On-Grade Edge Insulatio bath2 5.5 ft 0 60.5 ft� � 1 0 0
8 Slab-On-Grade Edge Insulatio bdrm4 35.5 ft 0 148.5 ft� � 0 0 1
9 Slab-On-Grade Edge Insulatio o wic 21 ft 0 104 ft� — 0 0 1
10SIab-On-Grade Edge Insulatio privy 1 ft 0 24 ftZ ___ 1 0 0
11SIab-On-Grade Edge Insulatio o bath 10.5 ft 0 117.3 ft2 � 1 0 0
12SIab-On-Grade Edge Insulatio laundry rm 9 ft 0 100 ftz — 1 0 0
13SIab-On-Grade Edge Insulatio foyer 22.5 ft 0 147.5 ftz � 1 0 0
14SIab-On-Grade Edge Insulatio hall 2 ft 0 42.5 ft2 � 0 0 1
ROOF
� Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2165 ft2 0 ft2 Medium 0.85 No 0.9 No 0 26.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1936 ftz N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) master 30 Blown 210 ftZ 0.1 Wood
2 Under Attic(Vented) family rm 30 Blown 341 ftZ 0.1 Wood
3 Under Attic(Vented) cafe 30 Blown 161 ftZ 0.1 Wood
4 Under Attic(Vented) kit 30 Blown 182 ftZ 0.1 Wood
5 Under Attic(Vented) bdrm2 30 Blown 147 ftZ 0.1 Wood
6 Under Attic(Vented) bdrm3 30 Blown 149 ftZ 0.1 Wood
7 Under Attic(Vented) bath2 30 Blown 61 ftZ 0.1 Wood
8 Under Attic(Vented) bdrm4 30 Blown 149 ftZ 0.1 Wood
9 Under Attic(Vented) o wic 30 Blown 104 ftz 0.1 Wood I
10 Under Attic(Vented) privy 30 Blown 24 ftz 0.1 Wood
11 Under Attic(Vented) o bath 30 Blown 117 ftZ 0.1 Wood
12 Under Attic(Vented) laundry rm 30 Blown 100 ftz 0.1 Wood
13 Under Attic(Vented) foyer 30 Blown 148 ftZ 0.1 Wood
14 Under Attic(Vented) hall 30 Blown 43 ftZ 0.1 Wood
8/7/2017 2:03 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2014
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
_ 1 S=>SW Exterior Concrete Block-Int Insul master 4.1 12 6 8 0 100.0 ftZ 0 0 0.6 0
_2 W=>NW Exterior Concrete Block-Int Insul master 4.1 17 0 8 0 136.0 ft2 0 0 0.6 0
_ 3 S=>SW Exterior Concrete Block-Int Insul family rm 4.1 14 6 9 4 135.3 ftZ 0 0 0.6 0
_ 4 E=>SE Exterior Concrete Block-Int Insul cafe 4.1 12 0 8 0 96.0 ftz 0 0 0.6 0
_ 5 S=>SW Exterior Concrete Block-Int Insul cafe 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0
_ 6 E=>SE Exterior Concrete Block-Int Insul kit 4.1 13 6 9 4 126.0 ftZ 0 0 0.6 0
_ 7 E=>SE Euterior Concrete Block-Int Insul bdrm2 4.1 10 6 8 0 84.0 ft� 0 0 0.6 0
_ 8 E=>SE Exterior Concrete Block-Int Insul bdrm3 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0
_ 9 E=>SE Exterior Concrete Block-Int Insul bath2 4 1 5 6 8 0 44.0 ftz 0 0 0.6 0
_10 N=>NE Exterior Concrete Block-Int Insul bdrtn4 4.1 13 6 8 0 108.0 ftZ 0 0 0.6 0
_11 E=>SE Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ftZ 0 0 0.6 0
_12 W=>NW Exterior Concrete Block-Int Insul bdrtn4 4 1 11 0 8 0 88.0 ftZ 0 0 0.6 0
_13 N=>NE Garage Frame-Wood o wic 11 28 4 8 0 226.7 ftZ 0 0.25 0.01 0
_14 W=>NW Exterior Concrete Block-Int Insul o wic 4.1 8 0 8 0 64.0 ftZ 0 0 0.6 0
_15 W=>NW Exterior Concrete Block-Int Insul o bath 4.1 10 6 8 0 84.0 ftZ 0 0 0.6 0
_16 N=>NE Garage Frame-Wood laundry rm 11 17 5 8 0 139.3 ft2 0 0.25 0.01 0
_17 N=>NE Exterior Concrete Block-Int Insul foyer 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0
_18 W=>NW Garage Frame-Wood foyer 11 15 1 9 4 140.8 fi� 0 0.25 0.01 0
_19 W=>NW Exterior Concrete Block-Int Insul foyer 4.1 2 5 9 4 22.6 ft2 0 0 0.6 0
_20 W=>NW Exterior Concrete Block-Int Insul hall 4.1 2 0 8 0 16.0 ftz 0 0 0.6 0
DOORS
# Ornt DoorType Space Storms U-Value Width Height Area
" Ft In Ft In
1 N=>NE Wood laundry rm None 4 2 8 6 8 17.8 ft2
2 N=>NE Insulated foyer None .2 3 6 8 20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/ Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 S=>SW 1 Metal Low-E Double Yes 0.54 0.31 23.0 ftZ 1 ft 0 in 0 ft 11 in None None
2 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 46.0 ftz 1 ft 0 in 0 ft 11 in None None
3 S=>SW 5 Metal Low-E Doubie Yes 0.56 0.32 33.3 ftz 2 ft 0 in 0 ft 6 in None None
4 E=>SE 7 Metal Low-E Double Yes 0.54 0.31 16.0 ftZ 1 ft 0 in 0 ft 11 in None None
5 E=>SE 8 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 1 ft 0 in 0 ft 11 in None None
6 N=>NE 10 Metal Low-E Double Yes 0.56 0.28 23.0 ftZ 1 ft 0 in 4 ft 2 in None None
8/7/2017 2:03 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6
�
FORM R405-2014
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 416ftZ 416ftz 43.7ft 8ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EqLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000322 1636 89.82 168.91 .2416 6
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump Split HSPF:8.5 32.8 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype E�ciency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER:15 34.2 kBtu/hr 1026 cfm 0.85 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftZ
DUCTS
/ —Supply— —Retum— Air CFM 25 CFM25 HVAC#
�� # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 387.2 ft family rm 96.8 ft� Proposed Qn laundry rm —cfm 58.1 cfm 0.03 0.50 1 1
8/7/2017 2:03 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2014
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Coolin Jan Feb Mar A r Ma X Jun X Jul Au � X Se ]Oct Nov Dec
Heatin9 �Jan �Feb �Mar f �Apr f �MaY 4 �Jun f �Jul ��Au9 4 �SeP f ]Oct �Nov �Dec
Ventin Jan Feb X Mar [X]A r [ Ma [ Jun [ Jul Au [ Se [X]Oct Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 SO 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(V1/EH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
, Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
�
8/7/2017 2:03 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 6 of 6
�ORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
, , FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ftZ
b.Frame-Wood,Adjacent R=11.0 506.78 ft2
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 4 d.N/A R= ftz
5. Is this a worst case? Yes 10.Ceiling Types Insulation Area
a.Under Attic(Vented) R=30.0 1936.00 ftZ �
6. Conditioned floor area(ftz) 1936 b.N/A R= ft= , ��
z
7. Windows" Description Area c.N/A R= ft
a. U-Factor Dbl, U=0.54 101.00 ftZ �1•Ducts R ftz
a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 33.33 ft�
SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: Dbl,U=0.56 23.00 ftZ a.Central Unit 34.2 SEER:15.00
SHGC: SHGC=0.28
d. U-Factor N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 32.8 HSPF:8.50
Area Weighted Average Overhang Depth: 1.212 ft.
Area Weighted Average SHGC: 0.308 �
8. Floor Types Insulation Area 14.Hot water systems
: a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft EF.0.95
b.N/A R= ft2
c.N/A R= �z b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building T�_Sr
Construction through the above energy saving features which will be installed (or exceeded) �,ya� � __ATA�,.': '
in this home before final inspection. Otherwise, a new EPL Display Card will be completed �k,�,,;�'�%f �:;`?,. ''�',,;�,. ', �i
based on installed Code compliant features. � ,,,,,.��rr,�-:;;;��;�;t�.°;,�p.
' �
BuilderSignature: Date: 11/08/17 �?. � ���(�'� `.��
�,�.
* ` �
Address of New Home: 3221 Moulde Hollow Drive Ciry/FL Zip Ze�hyrhills,FL 33540 , �'c-,. - � . �5`�"
- oD yvF,'� _
*Note: This is not a Building En rgy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if yo obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
8/7/2017 2:04 PM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
B111�C�117 Anal SIS Job: 1941A sf ADS
9 Y Date: 8/1412017
Entire House By: Dave
Bayonet Plumbing Heating and Air
' • - � �
For: Lennar Homes
� - • • • �
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD (°F) 39 16
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7
Dry bulb(°F) 31 91 Infiltration:
Daily range(°F) - 14 ( L ) Method Simplified
Wet bulb(°F) - 77 Construction quality Semi-tight
Wind speed(mph) 15.0 7.5 Fireplaces 0
Component Btuh/ftz Btuh °/a of load
Walls 5.6 6966 24.1 0��
GI2ZIIlg 30.2 5083 17.6 wa��
DOO�S 23.5 466 1.6 rrti�vation
Ceilings 1.3 2429 8.4
Floors 3.5 6726 23.3
Infiltration 2.8 3996 13.8
� Ducts 3223 11.2 -
Plpitlg 0 0 Glazing
Humidification 0 0 F�0°`�
Ventilation 0 0 ��Ceilings
Adjustments 0
Total 28888 100.0
� •
Component Btuh/ft2 Btuh % of load ,
Walls 2.8 3465 13.1 walls'
Glazing 55.0 9266 34.9 ntemal Gains
Doors 18.4 365 1.4
Ceilings 1.7 3358 12.7
Floors 0 0 0 =
Infiltration 0.6 880 3.3
Ducts 3621 13.7
Ventilation 0 0 �"`�S
Internal gains 5570 21.0 �iazing
Blower 0 0 Infiltration
Adjustments 0
Total 26524 100.0 Other Ceilings
Latent Cooling Load=4271 Btuh
Overall U-value= 0.104 Btuh/ft2-°F
Data entries checked.
.i, WI'1 htsoft' 2017-Aug-1410:39:51
�� g Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1
...th CBA27UHE AH's11941Asf ADS template 3ton.rup Calc=MJ8 Front Door faces: E
li
�-
Pro ect Summa1�� Job: 1941A sf ADS
1 ',7 Date: 8/1412017
Entire House By: Dave
Bayonet Plumbing Heating and Air
' � - • �
For: Lennar Homes
Notes: 2017
� - • • •
Weather: Tampa International AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 °F Outside db 91 °F
Inside db 70 °F Inside db 75 °F
Design TD 39 °F Design TD 16 °F
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 25666 Btuh Structure 22903 Btuh
Ducts 3223 Btuh Ducts 3621 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 28888 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 26524 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 3625 Btuh
, Ducts 646 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft2 1936 1936 Equipment latent load 4271 Btuh
. Volume�ft') 16360 16360
Air changes/hour 0.34 0.18 � Equipment Total Load (Sen+Lat) 30795 Btuh
Equiv.AVF (cfm) 93 49 Req. total capacity at 0.85 SHR 2.6 ton
Heating Equipment Summary Cooling Equipment Summary
Make Lennox Make Lennox
Trade 14HPX SERIES Trade 14HPX SERIES
Model 14HPX-036-230-21 Cond 14HPX-036-230-21
AHRI ref 10258589 Coil CBA27UHE-036-230*++TDR
AHRI ref 10258589
Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER
Heating input Sensible cooling 29580 Btuh ��
Heating output 32800 Btuh @ 47°F Latent cooling 5220 Btuh ,
Temperature rise 25 °F Total cooling 34800 Btuh
Actual air flow 1200 cfm Actual air flow. 1200 cfm
Air flow factor 0.042 cfm/Btuh Air flow factor 0.045 cfm/Btuh
, Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.86
Capacity balance point=29°F
� Backup: n/a n/a
Input= 0 kW, Output= 0 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
���+ wrightsoftm 2017-Aug-14 1039:51
Right-SuiteQ�l Universal 2017 17.0.23 RSU05714 Page 1
...th CBA27UHE AH's\1941A sf ADS template 3ton.rup Calc=MJS Front Door faces: E
. , , ., . . '
Manual S Com liance Re ort Job: 1941A sf ADS
p p Date: 8/1412017
Enfire House By: Dave
Bayonet Plumbing Heating and Air
' � - • �
For� Lennar Homes
• . • • •
Design Conditions
Outdoor design DB: 91.3°F Sensible gain: 26524 Btuh Entering coil DB• 75.6°F
Outdoor design WB� 77.3°F Latent gain: 4271 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 30795 Btuh
Indoor RH: 50% Estimated airflow: 1200 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230"++TDR
Actual airflow� 1200 cfm
Sensible capacity: 29070 Btuh 110% of load
Latent capacity� 5130 Btuh 120% of load
Total capacity: 34200 Btuh 111% of load SHR. 85% �
. . •
Design Conditions
Outdoor design DB: 30.8°F Heat loss: 28888 Btuh Entering coil DB: 69.7°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230*++TDR
Actual airflow: 1200 cfm ,
Output capacity: 32800 Btuh 114% of load Capacity balance: 29 °F
Supplemental heat required: 0 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: n/a Model: n/a+n/a
� Actual airflow: 1200 cfm
Output capacity: 0 kW 0% of load Temp. rise: 0 °F
Meets are all requirements of ACCA Manual S.
.�. wri htsoft° 2017-Aug-1410:39:51
1, 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1
'� ...th CBA27UHE AH's\1941Asf ADS template 3ton.rup Calc=MJS Front Doorfaces: E
' � 3221 Moulden Hollow Dr
SQ. FEET PRICE
MAIN OR LIVING: 2,372 $ 112.65
OTHER AREA UNDER ROOF: - $ 91.00
OTHER: - $ -
VALUATION $ 267,205.80
FEE SHEET $ 989.00
� ADDRESS $ 40.00
DRIVEWAY $ 40.00
� BUILDING: $ 1,088.78
ELECTRICAL: $ 222.53
PLUMBING: $ 148.35
MECHANICAL: $ 103.85
SUB-TOTAL $ 1,563.50
RADON: $ 35.58
TOTAL $ 7,599.08
SEWER: $ 2,010.00
WATER: $ 641.00
IRRIGATION: $ -
i TOTAL: $ 2,651.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 5,277.21
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00
' 99% $ 3,595.68
1% $ 36.32
TOTAL: $ 14,555.05
�
.� �` � � ,.`'���%" ��' } ��*,�'!..� : ����"`'� #�,
-.;��.:.. � a•
.. . � j� � , r�-. . �� , •�.r��� ��/7�y�IMIM�1'M.��������rfiW��l
, �Y 111�` ■�- '
. _ • � ?� •4` •�. �'` � , ____._ .._.., w .............. r...j,. � . .,..
. }, � 'i���� `'l l+ , ' .
.
.� .
i. ..: ' . SYr . ..
, ' ,
� ��` (�' ..:.,r'+ ,�t�,,. ; i � . �
• �� y � i...a: i � '
, ;'� �£, tr .`~"'""•r„� 7�,� . . . � 1 � �' ;�
- • _ � �G� � 14 . , � .�
� F��L � �� � � .��� F�El.
� � �� �; �-�1�-�- — "� �. 74,�Q ' �' _ 7+i;�d6
. . : �.�_.��._�....,�.�.__. �,_��—� � �._.r.r,� ,�..� A
`'� %'' � ....� , ..».... ,...»......,,.
; .....,......,,..�..s="� �"."
. . r��' � �� 7E�"Q ' � ' � � � e� �'F1
. � ; .� .. � �'4.'Jlt �� , 1 � '' �a7�., 7�i.f30 f
, . ' : :W...,�lt,.�'_.;.,��.:,... .... i+hl, � , .. !�'' � '- 1�'
„: . . ,
� , ��..._��:.,� ..__.....�. w.......+.�i,, L.a� .._......�.�_�
., � ` i �$ �Fa. t -�-__�.....___...,...,...� p�-__._.� ..,.�_�
, 4 ,�� ; � T A� � � �� �. � � � ��� �4.A
• �' �: �-��-� — — — i 'A , � €,p� � '. �` . ,
. p r_.�.�.,..�.�� �._ _,„�, .....��.,�..� .r.,,-»... . �
_ " = � : , �,,...._.__.._.�_.—`E i�._.�..�, ......�.-.....:,.
'�' � 4.50 i, ' i��L. � � FF E,3.
� , � • . �
, " �� � �� �� ' 33,��s �� � � j ' A� `�A.�
. . ��� . ����
:; . ;; �.�— — — . � ! �.
....ri,.,.,_....... ............�',�"'..,;'..,..,....,......._..,..._... �-—��.....— ....__.,. • ....,^. ..�...�,..�. ��.,..,�, r........
.,� : '1 5' � , ��.�..�..._���.a��....w.� S�.r rr.r w..w..�..�+�i.w•
r' < 's � ". ��•,... �� � �� _ i � • ��.
- ��' r� � z�.�s . �� � i i ��'�' �r�.a�
:. 4. �..�� '� .._.� .ti,, '� �, ,�,�,,' # - � � � �
� �-__••,,—•__—�._.a..� ;�, .� _,....' _. .,'�.'1`�'.w,.,,..,�.�_.�.
i f �
' } .i � � � '� �r����.r.a+,.:� t--ar ..�u.w e+. 4.�..�yw ry-
k p, �:�„ t; � :
� � .�`��,,.� '�+'��.9x �.� �F�'�!. � 1 � ' FF�.
� � � ��,_ y _ � '. '� r.��� �'� , � � � '��� ��►
, :� r � •�. , �� � � ��
� - /� - I I
, Y:;, t-. �. �+--' � :$� .�,�r ww.;�, w�u.� .Fw�L.��..�.....++.�.�.�w.q. j
i . i ■• �� t .
. t ` � � ' �..�.�.�...��.����T� ""�""
`v I ,. j :� � ... .r .r.w. ..r r ..w.w ai.u�.
. �� � t ���� �--�;
.:.� �:�, � i :� . ��, ,,,( /� ��j. ��'� � �r�ry,;:
, �. {3� `� `� � 4��`""_' '.~ � d.�.�i� �1�V ' ! t : �:fr'V r� .
� •,.. . ,; L .,._,...,..+.�.,.._, �'L A ' �� °'� �" ....
� ' ' R �. _..,...�_�_.;....u.. ��t1 . �. ,�,..,.,,.a. �,. _
, . , j . � _..,.....�.�.r,,,.,..,�......� �.———.�_ -._...__
.. . ``. � ' •.�y7 �� T3,5t9 �� FF�. . � � . F�€t. I
,,, ,= � � �'.
, . ' ` � �. . � : � �"�..: � .j ` '��"� �"A
� Y �...�.� ��-+� �M1' _ ` � "�,
: i .+�...__...�,..+�,....w.w...�._ i �' • w..._.� F 3*s" —— �-��
. r � ! • �
� ... R..,,......4-�'�-�..�_.� ��`� .—
, ' ' ; � f �`�, �,�ty � t � '� ''. . �---
, ,..,,_ ,.� � � A :Fi�Et. ��� . � �� . .. ��
� " ,�''� ?2.@�3 .�,� �� ��� T�f.".q
�. ' .f � �..�;i�'3c�. ,.,.......r.....w..M,.� �[ � • � � �
.....................,. .....,,.5... .._..,. ,_. .f,: ,, . ..f i �_.,....�....— l E�F.�. ' °3�..�,.��`�_»«»�'���,.....��„.,__...._
.� � ,�i, : �.,' "' "1 E�
,� ' •`{ � ,�.� � . ` FF T�1. {'�s I � F��t,
• �� � • i�.�S �t�I�a7 � � '�.`� 7�.OD/
. :�Y �....�'S�'� ,,.,.�„�.:' :�'y . �_�, A,! � A i
� , ; , r,�_.........�.........__^ • � _._ ....,� �,��' _ .._�.,.,,..,._ 1
� =' � � �..�_..�.�,..'.�.._,_.�.� E �..,�.�....,_.� .,......W.:....
..r� ' ' ; ! ��` .7�",�?�D �EI. E ' � � �F E9.
� � E � �� � ` � '1 d� � � "��'� '�°
� � � ���.���� �� � �� �� �
. . _ .. :
.... ....... ......_. ...,,,. ........ .....v.. ..M�. ,..,w..• yJ.,,_.,._'�' __.....�.. : - �. - .a..w ..�� .�...�.•�
i �,,,.-,'...�.�.��.�.�. ...,. '��� ""'"" ; ..,. ��_.--..�.� � .� �
��.,,�,� � =f� _» , ,..r......�_......� � � ^�F EL S
�. ,� r,,�` �� o ��' .. ��� � � 1 �.a�
�,.�^'� � � • � �� �F�l,. 4:. . ��. A ��� � � ��� A
,.,�', '�� �`� - �� � y 7�.�tt�:a '" . .,,. � F � ,��
.-'"� 1 4 � "^�-�`'`�. - �4""'�+-�. .
't � .,. �
f� ��•�L'S 11 . FF F�.�� � _ .' ! F�� `°'.�-�'„�'`...���J�'" ...,,,-....,e,� `"-�-,:. '+,�
� � '. �� � k � �d � �° - r � � , -�-....
��.� � `�-.. � �,
�� , ��. t �` �� . �'� `'-� � �t��i { � ��z.
�� �,'. � � � ,� . `�� .,, , � ,r ,,;� ��� �.�
��, ��''''���, �� �; �► e .. ; ,��� ,ti,�� ����.$ �� �
i 1'1 �� �� �4 .�` .. . .. , . 4 FF EI.. I v, _�, i l r.. _... •
� SKETCH ONLY SEC. 24 , TWP. 26 S, RNG. 21 E.
PL.OT PLAN NOT A BOUNDARY SURVEY
LOT 34 � eEaRwc e,asis: ,
HIDDEN RIVER PHASE ONE A NORTH 80UNDARY OF SUBJECT PLAT BEING S 89'40'43" E
� PASCO COUNTY, FLORIDA. �T THIS SURVEY IS SUBJECT TO ANY FACTS THAT
MAY BE DISCLOSED BY A FULL AND ACCURATE
PRELIMINARY DRAWI[VG: OiV LOT AREA CALCULATIONS 1�- TITLE SEARCH. ALSO SUBJECT TO SETBACKS,
THIS PLAN IS FOR PERMITf1NG PURPOSES LOT = 6599.81 SQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD.
ONLY, NOT FOR CONSTRUC110N. VERIFY LIVING AREA = 1556 SQ. FT.
ALL DIMENSIONS BEFORE ANY CONSTRUCl10N. ENTRY = 45 SQ. FT. M UNDERGROUND FOOTER, STEM WALL, AND
GARAGE = 407 SQ. FT. p UNDERGROUND UTILITIES ARE NOT LOCATED OR
LEGEND: COVERED LANAI = N/A gp_ �, _ SHOWN.
�-►= PROPOSED DRAINAGE FLOW PA110 =_23 SQ. FT. � DO NOT SCALE THIS PRINT DIMENSIONS AND
CONC_ DRIVE = 475 SQ. FT w
(00.00) = PROPOSED GRADE A/C & CONC PAD = 18 SQ. FT. ¢ NOTES TAKE PREFERENCE.
E-00.00 = EXISTING GRADE �
PRIVATE SIDEWALK = 29 SQ. FT DESCRIP710N NOT CONTAINING PLAT BOOK AND
IMPERVIOUS = 39 % PAGE INDICATES THAT PLAT IS IN
NOTES: = 2553 SQ. FT. PRELIMINARY STAGE AND IS SUBJECT TO
LOT GRADING TYPE = A SOD = 4047 SQ. FT CHANGE AND/OR REVISION.
PROPOSED PAD ELEVATION = N/A
FRONT SETBACK = 20' OFF LOT AREA CALGULATIONS CERTAIN DATA SHOWN HEREON BASED ON
SIDE SETBACK = 10' RIGHT OF WAY = 720.00 Sq. FT. ENGINEERING PLANS PROVIDED BY CLIENT.
REAR SETBACK = 10' DRIVE APRON = 144 SQ. FT. STRUCTURE TIES SHOWN HEREON DENOTES
PUBLIC SIDEWALK =_24� SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION
' - SOD = 336 SQ. FT. TO PROPERTY LINE.
TOTALS * = 10' DRAINAGE/UTILIN EASEMENT
AREA = 7319•81 SQ. FT.
DRIVEWAY = 619 SQ. FT.
SIDEWALK = 269 SQ. FT.
SOD = 4383 SQ. FT.
LOT 33
� I
i
r�2 ��� � w
PtAr ''�� �—� S 89°36'S8" E 109.99' �—� 9'� ^ 2so ' >
BOUN ARY I - �
�o o•
0 0_ Q
} � '� �- I ' :
a.�-. O 24.50�L1 *LI 20.$0' � �
�� I � q�C,o. 65'-0�. � O
' �w CO a+ I � �
� �
¢
, ' o°� ' W _ o _ w _20.�0- -- I —J�
J O UIZ�2U' M X -% � �
�O I � � d�rn �W i- Z9.00� O�
, �m O � �����J o . .I. .. N . Z�
a w • .�.' O
x� N `�ol•.' M �'
� � ^• �o'.r� rr.,.J�.l: ,; N•' • z
� O ..
2 I O - ' O.� �.L�
tw.i Z - . .24.50' -- . .. Q
I `o o- 29.67�I � �
-o 0
.� � y• : �
rw,cr .'i" ;�' -�� N 89'36'58" W 109.99' -l�' .;� •-: 25 0 ' � �
BUFFER/DRAINAGE & ry`ti ,��
LANDSCAPE EASEMENT L L
I
I LOT 35
N
� '�
d� . :
I �
d
�
O
M
�
c�i PC�P�
n '
0
�
� PROPOSED:
0
LOWEST FLOOR ELEVATIONS:
� LIVING AREA: 73.20'
� DESCRIP`�'IOM' GARAGE AREA: 72.66' I
Q LOT 34, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE A", ELEVATIONS REFERENCED TO
w AS RECORDED IN PLAT BOOK 074, PAGES 101 THROUGH 121, NATIONAL GEODETIC VERTICAL
� OF THE PUBLIC RECORDS OF PASCO COUNIY, FLORIDA. DATUM OF 1929. MEAN SEA
i w ' LEVEL= 00.00 FT.
�
a
� APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL N0. 12101 C 0458 F EFFECTIVE DATE: 9/26/2014
� LEGEND:
� (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, r�= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
� CONCRETE SLAB, CH= CHORD, CH6= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM�T= EASEMENT,
w F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
o PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, P6= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
= REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK,
� U P= UTILITY POLE, W F= WOOD FENCE, R = RADIAL � i
� JOHN R.BEACH&ASSOCIATES,INC. Drawn By� SMS Square Feet: 6599.81 t LENNAR HOMES
`m � SURVEYORS AND MAPPERS
v 911 WEST ST. PETERSBURG DRIVE Checked By:
= ONE OLDSMAR, FLORIDA 34677 JRB �
� WAY (813) 854-1276 FAX (813) 855-8370 Scale:
1"=30'
N NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 10 9 17 ACS �D ?J {
'v THE ORIGINAL RAISED SEAL OF A FLORIDA JOHN EACH AT
N LICENSED SURVEYOR AND MAPPER FLOR A R LAND SURVEYOR No. 2984 LB 4493
/ Revisions:
�
_I
. Q�o u - �
' , `�:$.. -�ff!������
- .�-
���_ `:J:..r,:' :[�-=,�
'"'C??k°.��"j.;;�,'_,,. ;�" l_.,�
��_ �'?,�'��-i7 :�,
.��� �' .
� City of Zephyrhills .
i BUILI�ING PLAN REVIEW CONIlVIEIVTS
Contractor/Homeowner: �'�{/1-��(,� �!-��}'yL
�
Date Received: � l �
Site: � ��1 �� � �l U(�(1 �'lf�
L/
Permit Type: �� � � � Z. � `� S 7`�(��
�
Approved w/no comments:❑ Approved w/the below
comments:
� Demed w/the below comments: ❑
�
Chis comment sheet all be kept with the pernut and/or plans.
, z � � �
:alvin w' -plans Examiner l�ate Contractor d/or Homeowner
(Require hen comments are present)
\\
t • • •
'
Single Family I�welling
Plan Review Comments
,
1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan.
2. Lots shall be graded to comply with R401.3 of the F.B.C.
3. Compaction test required if 24" or more of fill dirt is brought in at any one place.
4. Tie in survey required before pouring concrete.
5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have
expansion material. '
6. All setbacks shall be met. �
7. All property markers shall be uncovered and marked at time of first inspection.
, 8. All A.D.A. requirements shall be met.
9. No electric, plumbing,mechanical, or framing shall be covered without an inspection and
approval first.
10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).
11. Appliances shall not be installed in a location where subject to mechanical damage unless
protected by approved barriers. M303.4 of the F.B.0 '
12. Water heaters shall comply with section P607.3 of the F.B.C.
13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1
14. Return air in all bedrooms. F.B.C. M1620.4
15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C.
16. All glazing requirements are to be in accordance with R308.4 of the F.B.C.
17. All means of egress are to be in accordance with R311 of the F.B.C.
18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C.
19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker.
- 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating
or appliances or an attached garage. They shall be installed in accordance with the F.B.C.
21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all
� underground plumbing and electric.
22. All 2008 N.E.C. Codes will be enforced.
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0
24. In accordance with the Land Development Code, lots shall be sodded before final at least 10
feet around the structure.
25.A copy of the ener�y cacls shall be with permit at all times
26. Copy of final insulation renort shall be provided with permit before fina�
I� F.F.E.-Finished Floor Elevation
F.B.C-Florida Building Code 5�'�Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2008)
. �
Jacqueline Boges '
From: FATHOM <support@gwfathom.zendesk.com>
Sent: Thursday, February 1, 2018 1:03 PM
To: Jacqueline Boges
Subject: [Request received] 3221 Moulden Hollow Dr
� ##- Please type your repiy above this line -##
Hello Jacqueline Boges,
I �
Z
' We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
Best Regards,
' FATHOM Support Team
TO ADD ADDITIOIVAL COMMENTS, reply to this email or click the link below:
' ' httos://qwfathom.zendesk.com/hc/reauests/192180
!
°:p3 ; Jacqueline Boges
— ' Feb 1 , 1 1 03 AM MST
New service water, sewer and meter 3/4 for 3221 moulden hollow dr
This email is a service from FATHOM.
i
� � � - � PAS�� �����'Y, ��.�1R1�►�►►
. .`� � Permlt Na. ��
pate Permitted ��7_$_
Builder Name/Owner Name t,,P�rn rtld.r- ��'�`�8 Control#
County Parcef Na. �.��Zfi— Z/�j'j(�Rn..PJc�C.��3`�'U SubDiv: �t�o[e11 ��
AddresslLocation �ZZ-1 ��t,�dPl� �o��Q� CUe- � _____ �
GlassificatloNType of Use �9 ytGi t���l�f ,
TRANSPORTA7iON tMPACT FEE Rate: Sq.Ft Unit: ��, 37�-
Exempt � []Yes [] No Haw betermined
� impact Fee Amount $. 3�3Z- Zone Na. TAZ:
SGHOCtL{MPAGT FEE
Account (056j Singfe-Famtly Detached House Amount $ �(��'(p�2�
(057} MobtIa Home •
{058) flther Resldential
123) Collection Fee
Exempt �Yes [�No Fiow Determtned
AARKS AND OtECREAvft1N FEE
Lar+d Accaunt L.and Credit Land Tota1
Recreation Account Recreation Credit �Recreatian'Total
Zone TOTAL AMC?UNT $ ��q� �ib
Exempt (�Yes ❑ No How Determined
liBRARY FEE
Land Account Land GrediE Land 7otai
Facitity Account Facifity Credit Faciiify Total
Exemp# (�Yes [� iVo How Determined Tatai Amount ��
RESOURCEFEE ERU
TOTAL AMOUNT
Prepared By Checked By
NO CERTtFtCATE OF OCCUPANCY WiLL BE tSSUEQ OR FtNA!INSPECTICIN
PERFCIRMED UNTiL THE TOTAL AMOUNTS LlSTED HAVE
BEEN PAID AND .
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO CQUNTY I
Acknawtedgement betow does not Imp1y acceptance of concurrence,but simpiy receipt of a aopy of this farm,placing
the buliding permft owner on nottce of thls assessment and th�conditions of paymant for sams.
DATE f2ECEtVED BY
FtECE1P7 iVO. DATE BY
,
�.��•-.�=n-�,.�. .��-�..�.
PAsco couNnr
+�>4,�� DEVELfJRMENT SERVlCES
� �� ������` 8731 Cifizens Drtve Date:2l22l2018
CC7'UNTY FLORIDA New Port Richey,FL 34654
t_)3��SrAe�a.!%mr+n�r rianc�e. 727-847-24'13
** NO�T /� �'E��IT *�
Receipt#: 173�9642
FEE DESCRIPTION AGCOUNT CODE UN17S INVOJGE# �EE AMQUNT PAlD REGElPT# DAT�
Impact Fee Residential Solid 24503100-329010 54.74 1321804 $328.44 $328.44 1739842 2/22/18
Waste Single Family
TOTALS: �328.44 $328.44
Recel t Pa B Ch c # CC A�ath# Cashier ID Workstation ecei4t Date mt Paid
1T39642 Check OQ958412 54Q BCCCP06W 42122t2018 $328.44
Totai Payments: . $328.44 �
Pavor Address Pho e
Lennar Hornes LLC 4600 W.Cypress Street
SUIt$�0�
Tampa FL 33607
Camments•
Ciky of Zephyrhills
1J b Pett�lf 49140, ��/'
3144 Moulden Hollaw Dr. ""
� Permit 49242
3'i23 Moulden Iiollow Drl.�
y� Permit 192�3,
3111 Moulden Hollow Dr.�
t� y Permit 19244,
3221 Moulden Hollow Dr�
j t 1 Permit 192Ab,
3130 Moulden Hollow Dr.�"'
Permit18246 /
10 y 3200 Moulden Hollow Dr.'`�
Whlte yau w31I he paytng yaur btll vdth Pazca Covnty oevetapmeht Servtus,tha tutl amaunt ef the credlt tard or e-theck faes,NR7 shawn a6ava,is collecsed by
Flrst Bllling p�yment sarvices,
MyReparts/reports//PRODUCTION/PASCO1FteceiptPOS V5.tpt 2/22/2018 Page 1 of 1
' Jacqueline Boges ',
From: Nichole Spence(FATHOM)<support@gwfathom.zendesk.com>
Sent: Friday, February 9, 2018 6:32 PM
To: Jacqueline Boges,�,�����?� ��, _
Subject: [FATHOM] Re 3221`Mould'en Hollow Dr�
##- Piease type your reply above this line -##
Your request (#192180) has been updated. REPLY TO THIS EMAIL or click the link below:
https://awfathom.zendesk.com/hc/requests/192180
i --- --;
� �,-�f _ ; Nichole Spence (FATHOM) 2�
� __ . ;
' f � �
���--� Feb 9, 4.31 PM MST � `
Account# 88�91�5n-2-98=290.9 h�as_Eeen created service order for meter install will be created I
,
once mapping has been completed.
Best Regards,
Nichole � FATHOM Support
a
� "-� ' Jacqueline Boges
` , ;
`-c`-- ' Feb 1 , 11 03 AM MST
New service water sewer and meter 3 4 for 3221 moulden hollow dr
, /
' -- - - - - - - -. .. - - - - -- - - - - ----- - - - - -- - --
This email is a service from,FATHOM.
1
�
l
.r e '1 . � _
Jacqueline Boges
From: FATHOM <support@gwfathom.zendesk.com>
Sent: Thursday, February 15, 2018 4:03 PM
To: Jacqueline Boges
Subject: Request#192180: How would you rate the support you received?
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We'd love to hear what you think of our customer service. Please take a moment to answer one simple question by
clicking either link below:
How would you rate the support you received?
Good. I'm satisfied
Bad. I'm unsatisfied
Her ' �� [� '
e s a reminder of what your ticket was about: f �
1
�--- i
;
Nichole Spence (FATHOM)
_�� Feb 14, 1 .20 PM MST
Hello Jacqueline Boges,
The changes you requested have been completed. I
' I am markin this ticket as solved.
9
''�
Best Regards,
Nichole � FATHOM Support
�-----,
� Nichole Spence (FATHOM)
--=� �
`- -- --' Feb 9, 4.31 PM MST
�
Account# 889145-2982909 has been created, service order for meter install will be created
once mapping has been completed.
�
I
i
�
- . .. . ... .
Best Regards,
Nichole � FATHOM Support
� r��� Jacqueline Boges
�---'-�-' Feb 1 , 1 1�03 AM MST
New service water, sewer and meter 3/4 for 3221 moulden hollow dr
This email is a service from FATHOM.
2
. �. _ j � 5335 - 8TH SfREEf
(813}780-0020
CERTIFICATE 4F �CCUPANCY
Address: 3221 MC)ULDEN HOLL�W DR C?wner: LENNAR HOMES LLC
ZEPHYRHILLS, FL. 4600 W. CYPRESS ST STE 20Q
Subdiv: H{DDEN RIVER TAMPA FL 33607
Parcel: 24-26-21-0090-00000-0340 Work Type. 141-NEW CONST/SFR
Construction Type: NOT APPLICABLE ❑ Sprinkiers
Use Ciassification: NOT APPLICABLE
Permit Number: 19244
Date� 6/01I2018
��
lSSUE Y: BUILDI OFFIClAL :
WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE
GARBAGE DEP4SIT MUST BE APP�IED FOR PRI4R T4 ISSUANCE