HomeMy WebLinkAbout18-19267 �
CITY OF ZEPHYRHILLS .
• - 5335-8TH STREET
(�i3)�so-�ozo 19267
.,FIRE.�,ALARM SYSTEM PERMIT
� PERMIT INFORiVIATIOfV LOCATION INFORMATION-
Permit Number: 19267 Address: 6030 GALL BLVD
Permit Type: FIRE ALARM SYSTEM ZEPHYRHILLS, FL.
Class of Work: FIRE ALARM SYSTEM Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Square Feet: Subdivision: CITY OF ZEPHYRHILLS
Est. Value: Parcel Number: 03-26-21-0010-12800-0000
Improv. Cost: 5,200.00 OWNER INFORMATION
Date Issued: 2/14/2018 Name: GALL BOULEVARD LAND TRUST
Total Fees: 150.00 Address: 350 HARBOR PASSAGE
Amount Paid: 150.00 CLEARWATER, FL. 33767
Date Paid: 2/14/2018 Phone:
Work Desc: INSTALL FIRE ALARM DEVICE- BEALS OUTLET STORE
CONTRACTOR S APPLICATION FEES
PREMIER ELECTRICAL S LU IONS FIRE ALARM 50.00 FIRE INSPECTION FEES 50.00
EIRE PLAN REVIEW FEES 50.00
�/ � �
a /�✓
���
�
Ins ections Re uired
FIRE AC EPTANCE Final
FIRE ELEVATOR RECALL
Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire
prevention and protection related activities such as inspections, plan review,administrative fees,and other
costs related to the aforementioned.
Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of
the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final
inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All
work shall be pertormed in accordance with City Codes and Ordinances.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMME ENT."
ONTRACTOR SIGNATURE PERMIT OFFIC
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED
� ZEPHYRHILLS FIRE RESCUE DEPT- 813-780-0041
�� I
;�
�--�--�----�--£ - --- � —�.- - �— -' " - � --_- - - - - - -- `-�
�EPHYRHILLS' FIR� D�PA�TtV1EhlT
6907 Dairy Road, Zephyrhills, FL 33542
FOIRE �ERVICE IJSER FEES
� Ocaupar�c�Na.: �i
Plan No.: Cantractar: '
Business Name: - - �� , Billing Address:
Business Address: �R Q�O ��
Susiness Phone No.. Bill'sng Phone No.;
Business Fax No.: Billing Fax No.:
Contact: Contact:
PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE ALARMI FEE
8 Site Ptan NIC Mnual NIC Sprinkler $50 1stAlarm NIC
MuRi-Family/Commercial .06 sf 1st Re-inspection N/C Standpipes $50 2nd Alarm N/C
{Minimum Charge$25,Q0 2nd f2e-inspect€on $10D Flre Pump $5Q 3rd Atarm N1C
� Plan Revisfons DBL 3rd Re-inspection $250 Haods $50 4th Alarm $100
4th Re-tnspec6or� $500 Fir�Alarm $50 52h Alarm $'f 50
SPRINKLER SYSfiEMS (Business Gased until , LP Gas $50 6th Alarm $200
8 0-25 Heads $50 violations corrected) Natural Gas $50 HON co�tpiu�c� $150
2$plus HP..ads $100 SPRiNiCtER SYSTEIdOS Fuet Tanks- pertanx $50
STANpPIPE SYSTEM Hydra Undergrounds $45 Sparklers $100
�Per Riser $50 Hydrosfatic Test $65 persystem Fire Works $500
FIRE PUMP Acceptance Test $45 per system Camp Fire $25
Per Pump $10Q Hydrant Ftow $75 Controlted 8urn $'100
IRE/OLARRA SYS7EAA Haod/Duct $50
-25 Devlces $54 F(RE AtAR�t!SY5TE[�Y Ptace of Assembiy $50 Annuai
26 pius Devices $100 System Acceptance $50 Fire Protection $25
SUPPRESSIQM SYSTEMS RecaA Acceptance $50 Ftammable Application $50 annuat '
Wet $50 OTHER Waste Tire Storage $50 nnnuaf
Dry $50 Fire WalUSmoke Wall $15 per wall Generator<KW $100
CO2 $50 LP Gas $25 pertank Generator>30 KW 150
Olher $50 Natural Gas $25 persystem Bio-Hazard Waste $900 �+nnua�
KITCFtEN EXHAUST Fumigafion Tenting $50
�Hood/Duds $50 Tent 10'x10'or greater $15 per tent Toroh PoUApplied $50
O'tHElt Fire Pump $45 Haz.Ma#erials $'t00 rv,nve�
LP Instauation per tank $50 Fire Suppression $30
Fuei Tank Installation $50 System Acceptance
❑ (Per Tank) $50 �Exhaust HoodlDuct $30
Natura�Gas InstallaUon $50 Re-inspection DBL
(Per$ystem} {other tt►an annuat}
❑Spray Booth $50 � Inspection scheduled DBL 8
and cancelled less than
24 hours
Construction Insp. N1C
Emergency Vehicle A� $50 FALSE ALARM
�i PLANS TOTA��7�� iNSPECT{ON TOTAl.� PERM17 TOT �o TOTAL��
il
� GRAtdD 70TAL ����
�, Comments: j, �_ .
Da#e: 1 �� 1�'
lnspector: /"�'�-�----•�
mn
i
r
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed° restrictions"
which may be more restrictive than Couflty regu�ations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
- CONTRACTOR'S/OWNER'S AFFIDAVIT• I certify that all the information in this application is accurate and
that all work will be done in compliance with all applicable laws regulating construction, zoning and land
development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify
that no work or installation has commenced prior to issuance of a permit and that all work will be performed to
' meet standards of all laws regulating construction, County and City codes, zoning regulations, and land
development regulations in the jurisdiction. I also certify that I understand that the regulations of other I
govemment agencies may apply to the intended work, and that it is my responsibility to identify what actions I
' must take to be in compliance.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building O�cial from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S.117.03) ',�7
OWNER OR AGENT CONTRACTOR</r� �._ ------
' Subscribed and swom to(or a�rmed)before me this Subscribed and sworn to(or affirmed)before me this
by by
Who is/are personally knovm to me or has/have produced Who is/are ersqnally known to me or has/have produced
as identification. �(�. as identification.
v � ��/
i
Notary Public " /`� " v� Notary Public
Commission No. Comrpission No._ v7������3
� �� ��{�I �V� ��5
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped
I YP .
o`K` ° Notary Pubhc State of Florida
_ '� Plaomi Aviles
�a c� �Q My Commission GG 131883
p'�oF n,a� Expires 08/06/2021
�
s��asaoozo q ,��, City of Zephyrhiils Fire�� Fax-sla-7so-oo2�
� Permit A IE�ation
N�� . PP
_.
Date Received Phane Con2act for Permit �} ���i`�
...:'�� ��:�.~-�..� �. �
Owner"s Name Gall Bouleval'd Land Trust � _ Owners Phone Number C� � �]
Owner'sAddress 350 Harbor Passage,Clearwater, FL 33767�
Fee Simpie Titiehoider Name Titiehotder Phone Number �� � ��
Fee 5imple Titleholder Address
, ,,;,.. , . , , , „ , ;� , ,,,,, < , .. ,
JobAddress 030 Gall BLVD,Ze hyrhills, FI �ot# �
Sub Division � , Parcel# 03-26-21-0010-12800-0000
, ... . ,. , _ � .,.,�.,�����:��r� . v ,
� Bio-Hazard Waste Storage-ANNUAL Q Fumigation Tent
� Comm Exhaust Kitchen Hood/Duct � Hazardous Material(Tier II or RQ Facility)ANNUAL
oConfroiled 8um � Hood insfa(ia6on
� Emergency Generator<30 kw � LP/Natural Gas-Installation ,„J,
� Emergency Generator>30 kw Q �PlNatural Gas-AP1N[!AL Sale �jN�r �� I
� Fire Protection Maintenance-ANNUAL � Places af Assembly-ANNUAL� r
r y em� A�n er
Sprinkier � ❑ ❑ ❑ � RecreaUonai Bum /'���y,�4
� ��'I�ET-'
��
Fire Alarm � � O ❑ � � Sparkiers !
Hood Gleaning � ❑ ❑ ❑ � � Sprinkler System Installations � � l,J
Hood Suppressio� � � ❑ ❑ � � Standpipes{Sprinkier Sys} 1� ���� l��`�
� `
Fire Alarm Installation Torch Roofing/Tar Kettle I.iJJ �� �
Fire Pumps � Waste Tire Storage ANNIIAL ��
FlammableApplication-ANNUAL Valuation af Pro'ec�� ,
� � , S� �Q���
� Fuei Tanks _ ��
Q Other:
� ,.... -.,� � a
, _
, . ,
�.
Gontractor Company ►"��vi,.i�" - -
Signature Registered Y/N Fee Current /N
Address License#
ELEC7RICIAN Company
Signature Registered Y!t�l Fee Current Y/N
Address �icense#
PLUMBER Company
Signature Registered Y/N Fee Current Y/N
Address License#
MECHANICAL Company
Signature Regisfered Y/N Fee Current Y 1 N
Address License#
OTHER Company
Signature Registered Y/N Fee Current Y/N
Address License#
,, �.. ..,, _ w.�� ��--� ,, ,,,,,,,. ��,,.,,,.., �,,�
. . mv,��,h„ . ... , .,,�i,a�,...�r����,.".�i.�r�,�-"��,�„ , . ��.:;..:�W,:;�, „ „ . ..��,...._.""�,us:,,�
Directions:
Fili out appiication campleteiy
Owner&Contractor sign back of applicatian,notarized(Or,copy of signed contract with owner)
If over$2500,a Notice of Commencement is required(Mechanica!work over$5000)
Supply#wo{2}sets of drawings with appSiCable documerr#afion
Allow 10-14 days for review after submittal date. Parcel#-obtained from Property Tax Notice(http://appraiser.pascogov.com)
�
o 15��
/�� I�LO Il l ilP
• ' "�/ ��'-�,i��.
� �
� �'
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner:
Date Received: �—�-����
�
Site: �Dd���� �U�l-l/ ./�-J! /�.�
Permit Type: ��� ����
Approved w/no comments:LT Approved w/the below comments: ❑ Denied w/the below comments: ❑
� This comment sheet shall be kept with the permit and/or plans.
/ �- )--�� f�� .i �
Gene Brown—Fire Safety Officer Date Contractor and/or Homeowner '
(Required when comments are present)
�
FIRE ALARM SYSTElVI RECORD OF COMPLETION
To be comp/eted by the system insfallation contractor at fhe time of sysEem acceptance and approval.
� �
1. PROTECTED PROPERTY INFORMATION
Name of protected property: �eti1� �u�'���-
Address: �j��� ���� (�, l�a� Zc�l�v�u«.s ; ��
Description of property:� ��;` �
Occupancy type:
Name of property representative: �oh� �`r�;(�.,
Address:
Phone: Fax: E-mail:
Authority having jurisdiction over this property: L��y e� •ZePHvr�w��ls
Phone: C�13,7�0-002p Fax: E-mail:
2. FIRE ALARM SYSTEM INSTALLATION, SERVICE AND TESTING INFORMATION
Installer contractor for this equipment: P. I�r.S .S ,
Address: 3Sb� N 4�w7 1q(�► �LeJ�E- �e�x Fi. 3275"7
Phone:�YSS�96S' �72?7 Fax: ,s,,,„` E-mail: S.G3;,,�r�o..�PA�SS-FL , C...
Service organization for this equipment: . �.s cL� I e Sc���.4v
Address: I
Phone: �°�l�(�7�.2�?.Zo� Fax: E-mail: �
Location of s built drawings: Q,�,.�( Location of historical test reports: Q�,.��
Location of system operation and maintenance manuals: P„���
A contract for test and inspection in accordance with NFPA standards is in effect as of: 3/81 1g
Contract expires: 3/5�1� Contract number: Freq. of routine inspection: ,,.��
3.TYPES OF FIRE ALARM SYSTEM OR SERVICE
NFPA 72 Chapter Reference of System Type: 72
Name of organization receiving alarm signals with phone numbers (if applicable):
Alarm: S c� ��1 � � '�- Phone: (qlK��2L-22°o
Supervisory: �� �� Phone: �� ��
Trouble: �'� �� Phone: �� ��
Entity to which alarms are transmitted: �� �� Phone: �� '�
Method of retransmission of alarms to that organization or location: F{�.,.,�{- ! �1.,,,,�.
If Chapter 8, note the means of transmission from the protected premises to the central station:
�Digital alarm communicator _McCulloh _Multiplex _2-way radio _ 1-way radio _N/A
If Chapter 9,note the type of connection:_Local energy _Shunt _N/A
3.1 System Software
Operating system (executive)software revision level: �/�r
Site-specific software revision level: �/A
Revision completed by,N //�
Page 1 of 4
�— _
� n
'�___..�"'f �.��..•` c.:��'I a� a�
4�-� ��`-d a!s�1..,. f e't�,� . 8�c� {� �d d-�.� L:ti�� � �
L 6
5 � �b
� ,���;a,-t _
.e��b`>�`{..3 F,9�C.�'
.`
�_ ,
:.�u�ts'�.16%C}'� ,,, "i�. a�+..-�.
� � � � � ,y Q�a. � ", 4
���+•.'`� .��f' � { �`��•
- � � O
{- - ,i-� 1,��
. . -, , , . �
��<..;'a�G r.'7 i°�'t�� :'ae t i�"r� d�Y,�.; L�'wi�� . �� '2' .:�'s�'.,
f r y � �a 'y�e`
Q' Z.. . e `+�.�add�'1�'$ �%a�"�'�5`p.yl'��.w ��F-t �. �ti���-�1 � �ld°?d 'a:• �
� '
:� ��+- .:,. -i e 6�v�-s<n�O'..�. �
,�a .. r.e ; : ti.. {..� , !y'
.�a`ws. ws;��a e +�y m 'I
t (��s
�..:a,,.'� 1!el'.i- '� I
� ,�d '
t c�
., �� ^.
� `;-' i
1� � �'
�d�f s�.P'y'A-t 'l�b .� �yV
� 0
Z �
` `�"a"� �..�i �F''n���1 �t�tr"�a:�:-�~-- .:J.-�-}- ;:'��.:'�.,..
'1 0 .i,o" �� a �'.f
0 a .i/ r ;N _
�• �� e'y w
�r'`� t j.,.�j
a...d'`� 6 `ta.e1•F"E.�
.�
Y'�".��
�; ,z�f
r� . �/'
4. SIGNALING LINE CIRCUITS ' `
Characteristics of signaling line circuits connected fo system (see NFPA 72, Table 6.6.1)
Quantity: 2 Style: Y Class: '{;
5.�►LARM-IMITIATING DEVICES AND CIRCUITS
Characteristics of initiating device circuits connected to this system (see NFPA 72, Table 6.5)
Quantity• 2 style: Y Class: �
5.1 Manual Initiating Devices
5.1.1 Manual Pull Stations Number of manual pull stations: �
Type of devices: �Addressable _Conventional _Coded Transmitter _N/A
5.2 Automatic Initiating Devices
5.2.1 Area Smoke Detectors Number of smoke detectors: ��
Type of coverage:_Complete area �[ Partial area _Nonrequired partial area _N/A
Type of devices: �Addressable _Conventional _Coded _Transmitter _N/A
Type of smoke detector sensing technology: _lonization x Photoelectric
5.2.2 Duct Smoke Detectors Number of duct smoke detectors: ✓�
Type of coverage:_Complete area �Partial area _Nonrequired partial area _N/A
Type of devices: _Addressable _Conventional _Coded _Transmitter _N/A
Type of smoke detector sensing technology: _lonization �C Photoelectric
5.2.3 Heat Detectors Number of heat detectors: �
Type of coverage:_Complete area _Partial area _Nonrequired partial area 3C N/A
Type of devices: _Addressable _Conventional _Coded _Transmitter X N/A
5.2.4 Sprinkler Waterflow Detectors Number of waterflow detectors: l
Type of devices: �Addressable _Conventional _Coded _Transmitter _N/A
5.2.5 Alarm Verification Number of devices subject to alarm verification O
Alarm verification on this system is: _Enabled X Disabled _Set for seconds
6. SUPERVISORY SIGNAL-INITIATING DEVICES AfVD CIRCUITS
6.1 Sprinkler System Number of valve supervisory switches �
Type of devices: �Addressable _Conventional _Coded _Transmitter _N/A
6.2 Fire Pump
Type of fire pump: _Electric _Diesel
Type of fire pump supervisory devices: _Addressable _Conventional _Coded _Transmitter �N/A
Fire Pump Functions Supervised
_Fire pump power _Fire pump running _Fire pump phase reversal _Selector in not in auto position
_Engine or control panel trouble _Low fuel
other: N//�
6.3 Engine-Driven generator:
Type of generator supervisory devices: _Addressable _Conventional _Coded _Transmitter �( N/A
_Engine of control panel trouble _Generator running _Selector switch not in auto position _Low fuel
Other: N/Oa
Page 2 of 4
7.ANNUNCIATORS ' �
7.1 Annunciator 1 Local � Remote
Type: K Addressable _Directory _Graphic _N/A Location: ��o..i- cra�K.�
7.2 Annunciator 2 Local Remote
Type: _Addressable _Directory _Graphic )( N/A Location:
7.3 Annunciator 3 Local Remote
Type: _Addressable _Directory _Graphic � N/A Location�
8.ALARM NOTIFICATION APPLIANCES AIdD CIRCUITS
8.1 Emergency Voice Alarm Service
Number of single voice alarm channels: IV//� Number of multiple voice alarm channels: K//A
Number of speakers:_ _ N/l� Number of speaker zones: Pl��
8.2 Telephone Jacks
Number of telephone jacks installed: N/� Number of telephone handsets stored on site: N�a_
Type of telephone system installed: _Electrically powered _Sound powered �N/A
8.3 Nonvoice Audible System
Characteristics of notification appliance circuits connected to this system (see NFPA 72, Table 6.7):
Quantity: � Style: Y Class: �
8.4 Types and Quantities of Nonvoice Notification Appliances Installed
Bells: ��A With visual appliance: �/h Horns � With visual appliance. �
Chimes: N�p. With visual appliance: N�h-
Visual appliances without audible appliances: �� Other(describe):
9. EMERGENCY CONTROL FUNCTIONS ACTIVATED
_Hold-open door releasing devices _Smoke management or smoke control
_Door unlocking _Elevator recall _Other
10. SYSTEM POWER SUPPLY
10.1 Primary Power
Nominal voltage: iZOV�L Amps: l.3/�
Overcurrent protection: Type:��sr Amps: Zop�.
Location of primary supply panelboard:
Disconnecting means location:
10.2 Secondary Power
Location: N/�r Type: A►/Ar Nominal voltage: (U/14- Current rating: W�
Number of standby batteries: L�) 12.VDC Amp hour rating:�jg,ti.y-
Location of emergency generator: �ll�Q►�
Location of fuel storage: �l�1c
Calculated capacity of secondary power to drive the system
In standby mode: 2� In alarm mode: �
Page 3 of 4
_ �
�
, .��
� �
� _� �
��.:�.-�-:s,.: 'i r,.,•-'�
i{
s='>
i*,:�'l7 .�`�'�VE .
#`�`\�� $�� ,�'�
i�� '�r ��` R,.
T 8 � �
�a�
� ,u M
(� .� �" ��'i �/,i9��
�
•cci� ,7�� �{ 9�
i q
d s
��'•a -���`'��b
yj�=-.�. e y-a e� _� ,
' B 0
�;'����.%i '���i+l� .�'�'.,� { �:�'p+,�
9'i����. �'�'`...jtl i' .
R !J�
�`'a
��0 5
7/:,'��d7
.� � �+:
11. RECORD OF SYSTEM INSTALLATION � �
Fill out after insfallation is comp/ete and wiring has been checked for opens,shorts,ground faults, and improper 6ranching,but before conducfing
operational acceptance fests.
This system has been installed in accordance with the following NFPA standards: (Note any or all that apply.)
X NFPA 72 �t NFPA 70, National Electrical Code, Article 760
�Manufacturer's published instructions _Other(please specify):
System deviations from referenced NFPA standards: 7�.
Signed: ,�C� '�./�" Printed name: .�e�. (�:�k��., Date: 3/$f 1 S
Organization: Q,A.$. S. Title: ��s. /�,,,�„scr Phone:�4•�)940-8?�S'
12. RECORD OF SYSTEM OPERATION
All operational features and functions of this system were tested by or in the presence of the signer shown below, on
the date shown below, and were found to be operating properly in accordance with the requirements of:
!( NFPA 72 �NFPA 70, National Electrical Code, Article 760
�Manufacturer's published instructions _Other(please specify):
�Documentation in accordance with Inspection and Testing Form (Figure 10.6.2.3) is attached
Signed:�' �/��- Printed name:_ ��s� W:.��r�a, Date: 3/�/( �
Organization: P/�.,5.5. Title: ois, /��,�w z- Phone:[�07)7`�p-p'2�.5
13. CERTIFICATIONS AND APPROVALS
13.1 System Installation Contractor
This system as specified herein has been installed and tested according to all NFPA standards cited herein.
Signed: �l���„�-` Printed name: ��ti� (�,�„�.�,.{�,,, Date. 3/�jl �
Organization: p,J�._�j,�, Title: �is_ �'1..�...•tier Phone: C�a•� 790- $�2,5
13.2 System Service Contractor
This system as specified herein has been installed and tested according to all NFPA standards cited herein.
Signed: Printed name: Date:
Organization: Title: Phone:
13.3 Central Station
This system as specified herein will be monitored according to all NFPA standards cited herein.
Signed: Printed name: Date:
Organization: Title: Phone:
13.4 Property Representative
I accept this system as having been installed and tested to its specification and all NFPA standards cited herein.
Signed: Printed name: Date:
Organization: Title: Phone:
13.5 Authority Having Jurisdiction
I have witnessed a satisfactory acceptance test of this system and find it to be installed and operating properly in
accordance with all NFPA standards cited herein.
Signed: �,��_�.:�.,�-^f Printed name: C�G�^�//�v�--�'� Date: �3 b1 i�l'
Organization: �,�J �f �,�,�,i,�/�� Title: ��� �5,�<�r�~L Phone: I 3 7�� c7c.� �,
Reprinted with permission from NFPA 72,National Fire Alarm Code,Copyright°2007,National Fire Protection Association,Quincy,MA 02169 This II
reprinted material is not the complete and official position of the NFPA on the referenced subject which is represented only by the standard in its
entirety
Distributed by� AFAA—P O Box 1569 Jasper,GA 30143 Web—www.afaa.org
Phone—678-454-FIRE(3473) Fax—678-454-3474 Email-fire-alarm@afaa.org Page 4 of 4
� a��a j• •e.e r C.Si' �y�c�'W"-;Fr�.., rr..4at� i:. V... '
•_3 l L � � _
`�.t�iy``� -+..��,�--`� ��r�.•� �y�°t.•�r:,a, _,d ,.,�y � f � '
��_:�,._�_ _-.��-v, �.. -'.�S'- . @ a , .•r � ..:i' ...,
v +
?���r• �• ,q,� �`�.�v —.,,:
h�} y ._ \�` .`'•' .c.. "r,.'�� 4 B„ 'sv _.
,��""y.-�. _ �"�,_. ��r� �.e�'J r..i.a��� �9� a �..� ._.�
\G, - l�"
a�
�Y �
�'� iF� ..3� �. l'a„i• 4�}"Nast_,.`. i'�LZ.�q�� I��a
'' f t r
d.^,�Y._` ..�<-r.�-a�'; �av,r �.a• `...;l,o n� i c
;. '''''�, , - , ���� _ m` ,
.��
�� a�
- - a s
, _,_
� � Powerful
addressable fire
syste nn
�
�� ._
�
+ Proven�eiiabitiiysuitable for commercial and industrial
� - � __ -- instaAations
-- - . . = . • On-8aard 9D1]OO Network Commanication
• Full range of zone expansion,tommunication,and
relay output capability
• Fiash Updateable:No mare firmware chips iu replace
• Adaptive TechnotogyT""—Gost-effective supervised
celiatar backup
DMP XR]50�C/XR550FC Seri�s panels deiiv�r true
� flexibility and expandabiGiy to cover ail your�ire needs.
����oF�i�X��JJ���� $����$ Ci������:��� ���$� �����5
SYSTEM fFEA�URES
• 11p to 562 two-wire smoke detector or fire initiating zones on • Multiple on-board status LEDs
XR550FC • Up to 100 output schedules to control relays and panet outputs
• Up to 142 two-wire smoke detector or fire initiating zones on • 32 individual reporting areas.with common areas
XR150FC • Output Groups:Maximum functionaiity-Minimum programming
• Up to.5 Amps 12 VDC smoke and auxiliary output with OVC
protection XR150DIVFC/XR550DNFC SYSTEfiA FEATURES
• Up to.7 Amps 12 VDC supervised beU output • All above listed System Features 'il
• Up to 506 futly-programmable Form C relays • On-board Ethemet connec6on for Pfetwork MonitoringTm
• Seriat 3 Digital Diaier or CID reporting to mu(tipte receivers • Customizable check-in time and retry time
• Eight communication paths between the panel and Centrat Station • Suitab(e for multi-site applications where the Internet or
LAfV/WAN is avaitab(e
• Built-in remote or on-site feature upgrade capability - ,
• 12,000 event buffer
• Multi-lingual menus available by user
0
. • - .
r----__
�____.____--
___-- __---
��`!-- XR150FC & XR550F'C FIRE PANELS
The XR150DFC and XR550DFC provide basic fire monitoring for any single site application.The XR150DNFC and XR550DNFC panels provide
atl the same basic fire monitoring as the XR150DFC and XR550DFC snhanced by the on-board Ethemet connection that allows the use of
Neiwork MonitoringT"".Both panels come futly assembled from the factory with the following components:
CONTROL PAIdEL
The XR150FC and XR550FC Series addressabte fire panets provides comp(ete system control for tocal NAC operation and OACT.NET,or Cetl
communication to the central station.The microprocessor based panet aiso provides input for Class A zone expansion,conventional and
addressable smoke detectors,pull stations,and heat detedors.
ENCLOSURE
The endosure is comprised of cold rotled steel in Red to distinguish it far fire operation.For added security,the enc(osure comes with a lock
and key.
KEYPAD ANNUNCtATOR
The Fre Command Center mounted in the door of#ers a 32-character full text LCD readout that displays system events and menu prompts.
making it efficient and easy-to-use.
TRi41VSFORMER AND ENCLOSURE
The 16 VAC,5b VA wire-in transformer is tactory installed and features a built-in PTC for power circuit protedion.
XR150�C/XR550FC �'1(PiCAAL IVOTIFIC�►T°lON/ANNl1NCl�1TION
,� F 32�r 2/i VDC
'�`FFRE� F.�:�.�Y�i� NAC1
�'-•' f:-?..
12or2LVDC rtRt , ��
" Sync Module Strobe Mini-Hom
,x,c,:=�;�:' 11AC 1
:��,...,
,:�.: 4��, �--,Y-�, .��
�,� 12or2bVOC =y���
�-""^¢��`^' NAC2 r,.�:`�� 12or24VOC
Power Supply Sync Modute Hom Strobe NAC3
505-12 or other 12/2kVDC UL _ Motor Sell
Commercial Fire Approved pi9�q�
Digital SLC Power SuppGes Annunriator Bus
Loop 2
.
Digital SLC - Additional 630F
Any expansion device Loop 1 Fre Command
can operate on SLC Loop Centers
1 or2 630FFre
Command Center
FLEXIBLE COMMUNICATION NETWORK OR CELLULAR
The XR150DNFC and XR550DNFC COMMUNICATION
has transitioned from dialer-focused Built-in 10/100 auto-sensing Ethernet The check-in and faii time settings are
communications to a true network and connection enhances botfi standard and programmedforfiveminutes.Asthebackup
cellular communications approach by encryptedlinesecurityoptions.BotfiUDPand path,the263Cor2G3Hprovidesthesecurity
providing stronger, multi-layered panel TCP are supported.The network option can of a communication link that continues to
communications that ensure a constant beusedastheprimaryorbackuppathtothe function, even when land lines are cut or
tink between the panel and Central Station. digital dialer or cetlu(ar option. compromised.The communicators can be
Installers have the abiGty#o create,canfigure The XR150FC and XR55DFC Series Panels used as a stand-alone communicatar without
and manage up to eight communication may be used with the 263C or 263H Digital the need for a backup.This interface works on
paths. Celtular Communicator as the primary path digitat Celtular data networks over a variety of
The unique DMP Serial 3 format supports 1 b (no backup required) for commerciat fire carriers in the USA and Canada.
or 32-character user,zone and area names installations.
to decrease the centrat station response time
and limit dependence on automation literal
tables for message conversion.
.tl
�
E(GHT COMMUNlCATION PATHS NOTIFICATION CIRCUIT OUTPUTS
Create, configurs, and manage up to Qight EXPANSION The XR150FC and XR550FC allow tbe�ase�=
communicatian paths between the paneland Easity add NAC outputs to the XR150FC/ of two SPDT retay outputs and four open
Centrat Station.Each path has its own panel XR550FCsystem.Up to three Ciass B modules colledor outputs, that may be activated by
communication programming parameters, can be mounted within the FACP.Model865 or zone or sysiem events,by schedute,through
and can be iden#ified as either primary or 866 Ctass B NAC Modules may be combined the User Menu or when a card is presented.
backup.Thisenablesinstallerstoconfigurea with a power supply to provide additional4 Output Groups attow multiple outputs to
reliable communication link.offering greater Amp NAC outputs. Use an 867 on the SLC activate with a single event and/or can be
confidence that the panel will atways he Laop to further expand NAC circuits. assigned to a pa�ticutar user profi(e.
connected to the Centra(Station. OUTPUT SCHEDULES
FYRE DRILL AND ONE-MAN
COMMUNICATION FUNCTION 4Np►LK TEST Achieve maximum system flexibility with
DIAGNOSTICS Users can test fire notification betLs using 100 programmable schedules that simplify
The enhanced diagnostic menu enables the Fire Dritl feature.A special code is also Alanning and operations. Control any
technicians to check network and cellular avaitable#orinstatterstotestthesystem.The contact-ac#ivateddevicewithschedutesthat
communication status,celt signal strength, one-man walk test feature allows a single automaticalty regulate re(ays and switched-
and email status from the keypad. technician to check the panel respnnse to 9round outputs.
fire,burglary,panic and supervisory zones. �ryULTI-LINGUAL DISPLAYS
FIRE ZONE PROGRAMMING For additional flexibitity,keypads attached�o
Programzonesforfire.fireverifyr.fireretard. B�11LT II�1 PROGRAMMER �eXR150FCandXR550FCpanelscandisplay
presignal,cross zoning,or fire supervisory. AND DIAGNOSTICS keypad Status List and User Menu text using
This flexibiiity aliows the ability to match No programming device is required,enabling mutt9ple languages.The user has ihe option
individual zane characteristics to the needs instatters and service technicians to fiulty to select the language to use.
of any area in the fire installa#ion. program the system and run diagnostics from
any DMP LCD keypad. Check the electrical STATUS LIST
ZONE EXPANSION stateofzones,findindividuaizonenumbers. Tu pravide maximum system flexibility.6re
The XR150FCand XR550FC provide up to 570 check the LX-Bus for Missing.Overlapping Zanes may be pragrammed io display at�
zones, programmable for a variety of fire and/or Extra zones,and much more,a(t from specifickeypad,ln this manner.ali fire zones
applications.The system provides Ctass B any OMP LCD keypad. can be monitared in one location and other
12 VDC powered zones, two on-board and zones can 6e programmed to disptay and be
four on the 715 Modute, ptus eight pane( FLASH UPDATEABLE monitored at different keypad lacations.
burg(ary zones.lfp io 60 zones are available The XR150FC and XR55UFC panels accept
on i 5 keypad addresses and up to i00 zones software updates from a remo#e tocation 12,000 EVENT 1l�iEMORY
are available on each buitt-in LX-BusT�'using using Remo#e LinkT""software. When new Altows the user to view the last 10.000
Expansion Modules. XR150FC/XR55flFC feature updates retease, door accesses or 2.000 system events ihat
perform the f(ash update remotely, occurred over the ast 45 da s
FIRE 1/ERIFY P Y •
Usedprimarilyforsmokedetectorcircuitsto REMOTE LINK
verifytheexistenceofanactuatfirecondition. The Remote Link programming so#tware
When a Fire Verify zone initiates an alarm, takes advantage ofthe easy-to-use simplidty
the panel per�orms a Sensor Reset. If any of Microsoft�WindowsT"�.The XR150FC and
Fire Verify zone initiates an alarm within 120 XR550FC inctude an interface connection for
seconds after the reset,an atarm is indicated. installers to use to connect a iaptop computer.
lf an alarm is initiated after another 120
seconds,the cycle is repeated.
�-�--
__._.--- �
-- • - � - - . -
• � � '
– ____----``--��_ POWER SUPPLIES ��
_____._-�p� 505-1?JLX 5Amps@12VDC DMPWIRELESS TW���
630F LCA Remote Fire Command 505-12L 5 Amps�12 VDC 1100X Receiver �� �
505-12A 5 Amps @ 12 VDC 1100XH High Pawer Receiver
EXPAP1SIOfV MODULES 11UOR Repeater
7i0 BusSplitter/Repeater PULL STATIONS 1103 UniversatTransmitter.
711 Singte Zone Expansion 850 Series Pull Stations Externat Contact
714 4-zone Class-B Expansion SMOKE/HEAT DETECTORS 1165 Commeraat Smoke
714-8 8-zone Class-B Expansion 521 B/BXT Conventional5moke,CteanMe Detector
714-16 16-zone Class-B Expansion 521 UULXT Addressable Smoke/Heat, 1165H Commercial SmokelHeat
715 4-zone 2-wire smoke Expansion CieanMe Detector
715-8 8-zone 2-wire smoke Expansion 1165HS Commercial Smoke/Heat
715-16 16-zone 2-wire smoke Expansion ACCESSORIES Detectorwith Sounder
716 Output Expansion. 270 Idetwork Transient Suppressor 1181 Post Indicator Valve(UL)
4 Form C relays, 277 Commerciat Fre Buaer Module 1182 Outside Screw and Yoke Valve
4 open coUector outputs 300 Four-wire Hamess Supenrisory Switch NL)
717 Graphic Annunciator:20 open 303 Silence/Reset Push-8utton 1183-135F Heat Detector
collector outputs 305 Plug-in Output Retay 1183-135R Heat Detedor
CELLULAR COi1iIMUNICATORS 3D6 Tamper Hamess 1184 Carhon Monoxide Detedor
307-5 Screw-On Tamper Switch
263C CDMA Celtular Communicator 3U12 CGp-On Tamper Switch
2G3H HSPA+CeUularCommanicator 335 lntrt�sionSiren COMPUTER SOF'f1NARE
263HCAN HSPA+Cellular Communicator 370 Lightning Suppressor Remote Link Upload/0ownload
lAti require a 381 cabte) 374 Su�ge Voltage Suppressor Programming Software
AUXILIARY IVtODULES 381-2 18°Coax Extension System Link fnd-User Management
860 Retay flutput Modute 431 Output Harness Software
8b5 Style W/X Notification Circait g61 Power Distribution Mlodule Alarm Moniioring Modale
Modole Command Center Module
866 Style W Natifiration Grcuit CENTRAL STATION RECEIVERS Advanced Reporting Module
Module SCS-1 R Network Enabled Receiver Account Groups Module
867 LX-Bus Notifiption Circuit Compatable with Central Station Link Server AppGc�tion
Moduie Receivers that accept 5taadard C1D.
869 5tyle D Class A Initiating Ci�cuit DD.or DMP Serial 3 messaging
Modute SCS-VR�rtual Receiver) Software only
893A Duai Phone Line Module solution that runs on a server for network
IP and celtutar communications
SYSTEM SPECIFlCATIONS LISTINGS AND APPROVALS
Primary Power(included) 16 VAC 5b VA frensformer Refer to the XRt 50FC/XR55UFC Installation Guide CLT]297). XR150FC/
Secondary Power 12 VDC Battery XR550FC Programming Guide(LT 1232)and specific comptiance tistings
Models 365.366.368 or 369 for installation and programming requirements necessary to meet a
Output Rating particutar approval.
Bell Up to.7 Amps at 12 VDC FCC Part 68
Smoke and AuxiGary 1!p to.5 Amps at 12 VDC FCC Part 15 �
For UL instaUations.totat bell,smoke,and auxitiary cannot Underwriters Laboratories(UL)listed a
exceed 1.2 Amps using a 56 VA transformer. ANSINL 8b4 Fre Protective Signating �
Current Draw 180mA �
Enclosure: For approval information,access www.dmp.com and select Compliance. �
Material Cold-rolled steel(Red) � _
� —
� _
ORDERING INFORMAYION a'` _
XR150DFC-R XR150 Fire Contro(Panel = =
XR150DNFC-R XR150 Fire Control Panel with �o =
Network � =
� -
XR550DFC-R XR550 Fire Control Panel '� _
�fR559B R XR550 Fire Control Panel with o =
N �
�
��
o rtn h' Bo leva 8 �1 2 2 .com
• � � - • �es' ed, c Ass ,
'n E e! isso ri 658D3-8877
t � e M so
`: - - __,
. : , . — �
" � `:.`€�('s
�� ,:�:
— _ a pf
S#&Idaifllfi
�1� �DNY ���`��
Fire annua�ciation �sr�
soluta�ns —
: �
.... ..;b�..�..
,;; � :
_ t.,� - - .,
,,... .. ...... . v . ,...
.. ,_.. �
., . _..,�.:�.. w:..:�_.__ ....r
�� :h,-.�;-� r�i�-
u
; ,�
�'�
t ,,� j�`;_
,;'-' �;
_; „;�
::;_
;"�� �` � -- � �;� DMP�re Comman� K�ypads provide a variety
�,:� �� r���°' ""�"" �, , .=5 z- of�ire annvnciatian�elutians for re3idantial a�d
,� g� �;;�,: �; .��, ``f� zommerciai�ir�applicaiion�.
- .a� _
€,; ="�; "�'� �.—d ��; `- The b3�F provid��2-rhara�Yer full text LCD display
-�' of system�vents and m�nu prompt�far�ffici��t,
_� -'=�
_. �r:. �asy u�e.
. ;��:_
_.,,,:,.. �.._ .
.,...,,<:-;y...�,,;�,_._...:, b t
.......: .....,.,:�::.:.:,_,.a,H,,.�..>�
......._.
, -,: , <..,;- .<�,#.-,...�..:;..:...:........ e u tan acce�s to
, : 'l�ii� k�ypad aff�r�simpt�, nn
. ,�� . - ,. - _ .�'�u� , comman fP�ture�,inrluding:
� 5il�nz�aiarm�
+ l�eset s�n$ars
, + Test th�system
+ Pert�rm a�re dritl
�30F Di11l�P FIFtE COM6N�AIVD t�CI�YPAD
', FEA�URES
• Simpte hamess connection to 4-wire keypad bus • Flush or Serfiace mount
• At-a-gtance system status • Keyswitch enables single button operatinn
• Powered from panel or auxiliary power suppiy • Fult operation with authorized code
• Optional backboxes for conduit or wa(l mount apptications • Buitt-in diagnostics
• Attractive non-obtrusive designs • AC Power,Trouble.Atarm LED
• 2-button Panic keys • Compatible with XR100/XR500 Series
• 32-character LCD display • System events display in plain Engl'�sh
• 1 m • • • ' • • •
_-------`—'�__---
630F REMOTE ANNUNCIATOR g(���T-IN DIAGNOSTICS STATUS LEDS
The 630F Fire Command Center offers a pnintemaldiagnosticsprogramletsinstatlers The Green Power LED turns on when
32-character full text LCD readout that displays and service technicians test the operation of primary AC or DC powerto the pane!is at an
system events and menu prompts, making the keypad at any time without disabling the acceptabte level and flashes when its battery
it efficient and easy-to-use.The backbox and system, is tow or missing.
trim frame provide an attractive instaltation. A Yellow Trouble LED turns on when either
The keypad can either be flush-mounted or SUPERVISED AND UNSUPERVISED
surface-mounted. OPEFiAT10N the panel has faitedto communicate with the
The 630F keypad can be programmed for central station receiver or when phone line
supervised or unsupervised operation on 1 or 2 is in a bad condition_
the keypad data bus,increasing the overall
number of keypads you can instalt to provide
maximum ftexibility. When supervised,
T� " � the keypad occupies its own address.
a. -�
Unsapervised operation attows you ta install
'' ��� � r� multipte keypads on the bus with the same
address.
630F Keypad
SING�E-�U�TOf� OPERATBOf�
The b30F Fre Command Center has a factory
installed keyswitch that enabtes the four
function 6uttons—Atarm Silence, 5ystem
Reset,System Test,and Fire Orill.The user
can also access these four funcfions and many
more through the User Menu by entering a valid
usercode_
N
V
630F SPECIFICATiONS KEYPAD ACCESSORIES m
Operating Voltage 8.5 to 15 VDC 635 1.75"630F Attemate Surface Mount Backbox �
Current Draw 63mA standby 635F 2.5"630F Flush Mount Reptacement Backbox ��
92mA maximum 300 4-wire Replacement Hamess � ;
LISTINGS AND/APPROVALS � _
Trim Frame Dimensions 10.4"W x 7.0"H x 1.T'D C a l i f o m i a S t a t e F i�e M a r s h a l(C S F M) a =
Backbox Dimensions 8.75"W x 6.375"H x 2.5"D New York City(FDNY COA#6055) � �
Panel Compatibility XR100 and XR500 Series Panels FCC Part 15 'o �
Underwriters Laboratories(UL)Listed � =
ANSINL 864 Control Units for Fre Protective Signaling � �
ANSI/UL 985 Household Fire Waming o =
For additional information,access www dmp.com and select Compliance. N _
� —
�
� — � — . — 5 e sh t d 80U 8� c
g ie ssa 6 03
�� SYSTEM � ..�,�r
�� SENSOR� Y���?
,�,.
=:�;: � - �
xµ:. �.
���:��� : :;
..1�' , y .:I
Indoor Selectabie- �� ���`"��.� �
�.��:�
Out ut Strobes ancl - `Y�-�� �'�'��� `�
p r . _
.. - .-�:.
Horn Strobes for �- y==-� � - :.����
;� ,�� %
:��;�` , _ - -:�;,(,
Ceiling Applications - _ � _� _,�:_ __=-.
�:: -�.�..�,.�.= - _
- �.���� -_'�, � � - . _ :;�
�°�,. ,f_ � ' ,;f _ -- �. .
� �a�'�=�
System Sensor L-Series audible visible nnfificafion ;.,'� ;,';'w`..;. `�.�� t ��,�. ; ;
1 • .�t; � , ;G
. . �-...._,f,i~ 5 < � /
prQducts are rich vuith features guaranteed to cut �°��;.° 3;--^;-_;;�:A;:;;-';=-,,, -: ;':'�'>" `,
�.. . , -�- _: -.a.f. ;:
'�. :..-,.`;S�', !:" � : _ ,.
installafion ti�es and maximize profits wifh lower � � - _ �: s
_ ,. - : '_ `�-' �;H
..� ;
currenf draw and�nodern aesfhetics. �'����;-=�,:�t�-'== � : �.-��;?j`'� _�
�,,� �x
$ f .;-r ,.
�:�,,,,:
F@8t1J1'�S The System Sensor L-Se�ies offers the mos�versaiile ant�
• Plug-in design with minimal inirusion inia ihe back box
�easy-to-use line of homs,strobes,and hom strobes in the i�adustry
wiih lower currerat draws�nd rr�odem-a�sthetics.With white and red
• Temper-resistani constructimn plastic h�vsings,wa11 and ceiling mounting options,System 5ens�r
• Automaiic selection of 12-or 2A-volt op�rati�n L-Seri�s can rneet virivally a�y applicaiion requirement.
at 15 and 30 candela
The entite L�eries product line ofi ceiling-mount strob�s and horn
• Feld-seleciable ca�dela seitings on ceiling uniis:
15,30,75,95,115,150,an�d 177 strob�s include a variery of features that increase their applicatson
versai;lity while simplifying instaNation.All devices#eature a plug-in
• Hom rated at 88+dBA at 16 volts �lesign�vith minimal intrusion into the back box,making insialiations
• Rotary switch for horn tone and iwo volume s�lectie�ns fast and foalproofi whife virtually eliminating costly and time-
• Universal mounting plate for ceiling uniis consuming ground faults.
• Mounting plate shorting spring feature checks wiring continuity To further sfmplify installation,the L-Series utilizes a universal
before device installation mounting plate so installers can mount them to a wide�rray of back
• ElectricaNy Compatible with legacy SpectrAlert and SpectrAlert boxes.l�Vith an onboard shorting spring,instalfers can test�viring
Advance devices continuity before the device is installed.
• Compatible with MDL3 sync module
Installers can also easily adapt devices to a suit a�vide range of
• Listed for ceiling mounting only application requirements using field-selectable candela settings,
automatic selection of 12-or 24 volt operation,and a roiary switch
for horn tones with two volume selections. �
Agency Listings
sicxauNc
U� �rv�o �.
usreo
s5st2 FM aPwwed e■cePt 7125-1653�,Y,fl4
SA0�7 faAl.EfiTnwde�s Tti.t1653�Y13
3957�3
,
L-Series Specifications
. .
�
Generai � I
L-Series ceiling-mount strobes and hom strabes shall mount to a standard 4 x 4 x i'/z-fnch back bax,4inch octagpn back box,or double- �
gang back bax.Two-vr�re praducis shall also mount ta a single-garag 2 x 4 x I7ld-incfi�back box.A universal mounting plate sha11 be used I
far mounting ceiling and wall products.The notification appliance circuit wiring sh�dl terminate at the universal mounting plate.Also,L-Series
products,when used with the Syne•Circuit�"Module accessory,shal)be powered from a non-coded notification appliance circuit output
and sha�l aperate on a nami�a�12 or 24 voSfs.LNhsn used with the Sync•Circu3t�oduie,i2-vait-ra#ed no6fication appliance ciroui�outputs
sh�ll operate between 8.5 a�d i7.5 volts;2A-volt-rated notification appliance circuit outputs shail operate between 16.5 and 33�olts.Indoor
L-Series products shall aperate beiwreen 32 and 120 degrees Fahrenheit from a regulaied DG or full-wave recti#ied unfiltered po�ver supply.
Ceiling s#rabes and horn strobes sha11 have#ield-seiectable cande3a settings z�cluding 15,30,75,85.115.15fl,and 177.
Strohe
The strobe shall be a System Sensor t Series tvlodei �isted to UL 197i and shall be approved{or#ir�pratectiue service.The strobe
shall be wired as a primary-signafing notification appliance and comply wi#h the Americans wiih Disabilities Act requirements for visibfe
signaiing aPRliarices,#lashing at t Nz ovar the sUobe's en#ire operating voltage range.T3-�e strot�e 3ighi s1�a11 consisi o#a xe�on#tash tube and
assaciated tenslreffector sys#em.
Hom Sirobe Combtnatfon
The horn strob�shall be��ystem Sensor L-S�ries Model iist�d to UL 1971��d UL 46�and sha11 be approved�or�ire�rotect+ve
service.TI7e horn sirabe shail be wired as a primary-signaling notiidc�iion appliar�ce an�'cornply with�h,e Arrtericarrs v✓+ih Disabiliiies Act
requiremants far v'ssit�I�sit�naling appliances,f3ashir�g�t 1 Nz o�er�e st�o�e's�r�tfre operating volia��ranga.77ae�irobe�i�}�t shal9 c�nsi�t
of a xenon fiash tube�nd asso�iaied lensi're#lector sysiem.The hnrra sha�i�ave�twa au�ibility options and an�ption#a�wiir�h be�reen a
temporai ihree pattem and a non-#emporal(con�inuous)patiem.These opUons are set by a muiYiple pasition switch.`37ae hom ara hom strobe
madels sh��9��erate on�c�d�d�r a��r�-cr�d�d�ow�r suP3�jY
S�tnctim,r�t�attQn M�duta
T'he modute st��ll be�Syst�n'3 5�t��z�r 5}mc•�irc�sit mad�l iv�L�L:3�ist�ei to 11L�6A�rrd�h�11 b��pprovet3#t�r#ore prot�ctiv��eni,�e.Th��r+oz�ut�
�fi�all syn�hronize C.-Seri���trab'���t 1 N��nd horn��t temporal�trse,d41so,whiie e��er�ting the strob'es,the mo��1�sh�ii silence the homs
an ham sttob�nioz�els�v�t�s�ne�3�A�ar est wires.'t'he�adul�s"�al1 r�ount t�a�!t ilt�x�'t�xi�x�ii$-inch back box,'���o�aule�h��l aisc�
contral two�tyi�1'(�tass�)circuits or�ne Styt����l�ss�}circuii.i`f�e mor�ule shall s}+�chrani2e muitipte zar+es,i��isy chain'mg�wo�r znore
synchroni��atian mrt�dules tz�g�ti��r will s}+r��Mr`or�i.z�ail 2h��dn�s they aoniroi.'fh�mo�dule shail not op�rate ar�a cod�c�p�o�,r�w suppiy.
�i k R
9tand�rd�Dp�r�tingl�mp�r�t�r� ��°F co t�d"F{b��to 49°�?
M�mttil#y�ang� 1�3 to 9�°7n nox��corrder�sirrg
Strob��I�sh AatQ 1 flash pei�seGand
i+1�3tt1t�€�1 V�lt��Q i��;gulated 1�V�i�ot r�guE�t�ct��I��t�VRi
Aper�fln�VAlt�g�F��n�e@ 8 to 17,5�(1�V nomin�l)c�r 15 to�3 V(24 V nomiri�l)
� �ratin�VglEaq���ng�(N1�6�� 8.�id��.SV(a��namtnal��r 16,a to 3�V(�dV nQm����l}
In��t1'�Yt1t►n�1 Wie��8��� i2 to 1�AtNG
0�3111ng•i�oun4 DirnQnelon�(Inciuding 10ne) 6.�"diam�t�r x 2.5"high�173 mm�iameter x 6�mm high)
C�#Iing-Motan#8tte#�c�Mo�n#��cit�ox Sktet Dltn�n�lcns 6,9'd�am�t�t x 3.4°high(1�5:nm di�rnet�r x�6�m ht�h}
(SHBCE�L,SBBCWL)
Notes:
1 Fuli Wave Rectified{FNIR}voltage is a non-regulaie�l.t3me varying paw�t source that is used on som�power supply�r�d panel ouiputs.
2.P,S,PC,and SC products will aperate at 1 P V nominal only for 15 and 30 cd.
AVDS8e800
UL Curr�ent Draw Data
..� .
8-17.5 Voits 1Cr33 Volts
Candela DC DC FWR
15 87 41 80
30 153 63 86
75 N/A 1'I i 142
95 N/A 134 164
115 N/A 158 191
150 N/A 189 228
177 N/A 226 264
� . ..
, ' &17.5 Volts 16-33 Volts
DClnput 15cd• 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd
Temporal High 103 167 71 90 143 i65 187 217 254
Temporal Low 96 165 54 71 i37 16i 185 2i1 249
NorrTemporal High 106 �i73 71 90 �47 i65 i87 230 273
Non-Temportai Low 95 i 66 54 71 124 7 61 17fl 216 258
3.1KTemporalHigh 1"11 yfi4 69 94 7�7 163 184 2�9 257
3.1KTemporalLow 103 763 bd 88 3�3 155 185 21� 2�2
3.iKNon-TemporaiHigh 711 i72 69 94 1�t 164 2fl2 229 27'!
3.1K Nora-Temporai Lativ 1�3 '!S8 b4 88 13� i�� 78� �17 259
16-33 Voits
FWRinput 15cd 3Qcd 75cd 95cd 115cd 150cd 17Tcd
Temporal Hi�h i0a 135 17J 196 223 254 28fi
Temporal Low 78 7fli 1b1 1�� '199 229 262
iVon-Temporat High 107 735 179 1�8 223 25� 286
No�Temportal Low 78 iC1i 351 17� 798 229 �262
3.13CT�mpora1High ��g �3g� 7?9 20t7 �2b �55 2g9
3.1 K Temporal Low 79 101 150 171 196 229 260
3.1K Non-Temporal High 108 135 179 20D 225 255 289
3.1 K Non-Temporai Low 79 101 150 171 196 229 260
Horn:StrobeTones and Sound Output Data
. . ..• •
8-17.5 16-33
VoFts Volts
Sn►itch Position Sound Pattem dB DC DC FWR
1 Temporal High 84 89 89
2 Temporal Low 75 83 83
3 Non-Temporal High 85 90 90
4 Non-Temporal Low 76 84 84
5 3.1 KHz Temporal High 83 88 88
6 3.1 KHz Tempora! Low 76 82 82
7 3.1 KHz Non-l'emporal High 84 89 89
8 3.1 KHz Non-Temporal Low 77 83 83
AVDSBfiE�l
L-Series Dimensions
2.A7 �---�,
1.37 �6.92 -� �2.50
Q5 f.83 � �
�
��,...� , i
a o 0
�
0 0 0 0 0
o �o �
0 o p o 0
Ceiling-Mount Horn�trobes Ceiling Surtace Mount 8ack Box
�
�
m
o �
�����n
� �o
v
� m 0
m �
m �
Ceiling Mount Hom Strobes with Ceiting Surtace Mount Back Box
L-Series Ordering Information
..- .- . . •�- �-
Ceiling Horn Strobes Ceiling Strobes
PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red
PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White
SCWI-CLR-ALERT Strobe,White,ALERT
Accessories
TRC-2 Universal Ceiling Trim Ring Red
TRG2W Universal Ceiling Trim Ring White
SBBCRL Ceiling Surface Mount Back Box,Red
586CWL Ceiling Surface Mount Back Box,White
� S�STEM ��»S��„��,..�:.
�.� SENSOR� 3825 Ohio Avenue•St.Charles.IL 60174 Froductspecifk:atlo*isa��ecllocfiangew�tlmtrtrW.icaYsitgsta�seua.com
Phone:800-SENSOR2•Fax:630-377-6495 '°�amcvrtpruduct�n!wiatix,�rxkWmgYnela.stt�sior+ofGtisdatashzr.t
AVDS858p I•03/77
. �--�
i� � - � �
� �� � � � � � � �.�
., . ._ .. ..__. ..... ..:._,.�.�.�.._:_._�.n�._._...,:,. _ �
_ �-....�:-.m�-�_ = �.u�...�_.�.�_.�..__ �.� �___�. . , ._ .._�. . _ .
� �°��'� �:�
LlSTED
. ... ,
.. .. .. . -
,.:..,.....,. _ __
., �,
Si�ple o�eration
�` � ' � � � � � �e���edes ins�e�nt
F , � � �� ;.
;,° i `� `���� � �' a���°m
f;,y �
/� �.. ".,-.-+r+ _ ' , _ �'4.�"O4rm,� s�.:,
;'Y _ '_ _ ( � ` �s 7s=.,� " g�'i .'3�
�:A. -�:: ;tU .`,, �, \`` *i;�' �
_ �'�%Qit� �' "�.tirs� �:
`;`; ' _�_ -. : . , --, '-��p
a.�,.�s.._ __ :�-�.�fiv
� �-,.._._.,�,.��� ;",
!S° ' � G,���T � `���gf,''",��� f i
��'� �y� ��,� �' �� � ��i4„"�„Y
—_._=._.:sa�.+w ��t� �;+�z:bd;}�Ne�
i.
- � - ���� E.�3.
�r`.^
� .it� .';
,;� �'
..,� t ' '�'
� �'_
- �:
"i::
'`� �. �3
��� The 850 Series Fire Alarm Pull stations offer
-- .���:,
- quick and simple operation that's economical
- ,,r,,;, ., and reliable.
: _ .,. -- '"�- .,`F:
w . ,: rF�,:�.��r;;-�.:_��s�:'�' • Available in single or dual-action manual
pulls
• SPST contacts and terminal strip
connections
• Gold-plated contacts to avoid the risk of
corrosion
���� �Q�,�,�� �� �� �'1���
�SOS � �S�D► ,
__ . _ ....._....a._�.; .,.... , - �:����_ - - - _. .__ _ _
.
. _ ,.._ , .. ,.,�:N�..�; -
��a'ru�t��
� •�Approvals: UC and CSFM , • Mounts on standard-single-gang box .
, .. '• Americans;with:DisabilitiesAct;(ADA)compliant: - „-,. � • Optional surface:and.weatherproof backboxes.available
�- •`Die-cast'metaC construction .� � � , , � �• High=gtoss red�enamet finish . - '
� ��.Reset.key - ' � , • Scoced acrylic breakrod ., ��
7 .. . ,.- ,. . � -�,;, - ;� .� , .. ... .. .. _ -�
.ti -.1� � _ ' _ _ _ " - 4x4C' '
"S'_ 'i.. �'J�J"' ��.FW� '� 'Y. -
.FY.ti' :iJ� ' S.' . ,
.:C" .5.� 'S
�\; �7 .S. - ,�Sr� , -
4� r.
.. . , �. :k " .,., "" . ' _ '. ' ' , .. ,
k'.r t - _ - ..
,. ,�;
; .� .._�. - - �,:
.•:
.�,. �
f,., , .. . _..: ,�. . .:
.._ _ _, , " ' ' , ' , _. _ . - ' -.._ ,.. � . . .� -.. . �..d,._ ' _ ,., _ , .
_. _ . . ' � , � � , . ', _ , .'. _ . . , _. _ _. _ � . ._.i_ _ .' '_ ' .,. - .
E - . . ' � ..'_ ' ' _ � _ , ' ' " . ' - >. . - ' '-'. . _ . _ ' . _ .� .
�F` .. - - - '� ` ' ` ' _ " � `_' " . � '' ' ` ' . � _'. , . , • .. . " . �
L :, . i ` � - ,- , - •
i 1
, , _ .. �� � -� �v�r�,�r:vrA� , r', �a�'�Ci"�u "^t � �E. a_ . - ., .!
,7�* te� +l 11�_�.� -c 1 a�;� _` � , ��� '�. - '� t - �
W �,�.r�s �f�,�5�:w :-�.'�
.a,'w,+T° .� "'."r"p' �+�W ,�,6w.W=aPv�r� ::.P� -�9�e+::;ww, - �-- B; ' ,„„�,hv - ' ' '" I
�_- - ,r,,.,,�, -_� . w+ �v'r�wc�.- -r _ - .� x, � -
-�a'F a _sa�'�:F. - _ '�+��.� .vn^� .:ssF -2` <- ,c -y�.: - •;•,ys --��.-
3i3
.�`�h�� - -4S E` �' .-s� 4 �_ 1 Y� ' � ,
���_.
��.:
� _
�
������ ��� ���� ����� ���� ����'���
�,w,.�r._�..<... .: - -- - ..._ _ _ _ .
... .., �.- - � ;,– :.s--:�-�
_ ,..,.„ _. _..,..�_ .�M__.___�..._..,..K,r,u..�..�_�,�..,..�.
DESCEtIPTBOt�I MOt1E�T19VG OP'1'�Ot�IS BS�D O�EF3�4TiOfi'�
The DMP 850 Series Fire Alarm Pull A variety of mounting options are On the Model 850D Dual Action Pull
Station is a high quality, die-cast available for the 850 series. It can be Station, the push bar rotates inward
metal manual pull station available flush mounted to a standard sin�le gang allowing the PULL handle to be grasped
in either single-action or dual-action switch box or surface mounted in two in a one handed motion.
configurations with SPST contacts and optional configurations. The Model
terminal strip connections.The normally 850-SB Interior Surface Backbox or the AD�RESS,��LE ZOnIE
open contact,which closes when the pull Model 850-WP Weatherproof Backbox To create an addressable reporting zone
station is activated,is rated for 1 Amp C� both allow conduit connection to the for the 850 Series, install a Model 711
30 VDC.The contacts are gold-plated to 850 Series Pull Stations. Zone Expansion module.
avoid corrosion risks.
Scored acrylic breakrods are used with 8SOS OPEi�ATOO�i
the 850 series. The Model 8505 Sin�teAction Pull Station
is operated by pulling the handle on the
g���,����g� front of the station as far down as it
The 850 series has been tested by UL for �oes. When the handle locks into place
compliance to the latest requirements �t is easily visible from up to 50 feet.
of the ADA. Reset the handle by opening the station
with the supplied key,placing the handle
in the normal upright position and
re-lockin�the station.
PULL Screw
Terminals
To Fire Alarm To next
Control Panel device or
EOL resistor
Model 850 Wiring Diagram
SPECIFICATIOt�@S � ���•. ' , ORIDE6�8i+iG iL��OAt�/AYION �"'
$witch Rating , 1 Amp,C�30 VDC , � 8505 Single-action pull station o �
Dimensions 4J5"�H.x 3.25"N!-x 2.25"D� � 850D Dual-action pull station �-
, Color �, , " Red w/raised�,white letters;white 850-5B Interior surface sheetmetal backbox � -
� - � • PULL handle w/raised red letters 850-WP Weatherproof surface die-cast backbox �_
CO[+�P/��'l�1LITY'_ � � _ ' 850-AR Scored acrylic breakrods(1 dozen) �_
The.850 Series Fire Pull Station�is,compatible.with-alC 8505/711 Single-action pull station w/addressable module o_
DMP Com,mand Processors..; ��. ,, � � 850D/711 Dual-action pull station w/addressable module 0 �
- � � : , � • f " � ( Note:All models are supplied with one scored acrylic breakrod and �=
- - � .. one key. �-
�-
o _
• II I � � : i � � • �
� 2500 North.Partnershi Boulevard
�"�� . . � P
°�e�'""�^;�^^sP�°�� , . _ � Springfield, Missouri 65803-8877 ��
V u in �I' f Y�
-- - _--------_______--______-�:��
� ���
-------___
�� ��
f;� ��, ''-'''----_ -- ,
��o �--�—_
Faster 6nsta6latiora
v- . _ vvith more precise
�� .:�
"�LL� i`��� response to a9arr�s
.�;'`�' ' K�`�,
', ��s_ ..��i�, y ,���A .��: - �_:�w;.
� � .���,�, � ,,.s,�,:., '-�,
.-i r �.i - - � ,., .`�: .
, � ,
��� � f= ''S- Each detector reports alarms batk to the panel
;';E4L`=: -`.,�� ���.�, , �:;�„�:s:'��:���y�E' �
. �� � .,��s ,„ ,� � with its address.
� E; �' f,.;���6� .� , � � r� � ,,.�.
;r. ' �r. - y,: , '
;�� ,:. � : � � _ , • Reduced wiring speeds installati�n time
y,:. a���� � j { � ' � .� � ��
`��t �4 5_ „ a ,GG_�, ,,,,, � t ' � • Emergency responders know where to go
� �� j�i' 'if{i� T �IJI
� w �
„ d _�`��r ,� 4 -:��f t '��✓�'� � _ '- ' r:
� ' � r : ' ' " ; � ��� ` ���� +�@ : , e Trovble alerts 3o a spe�ifi�d�t�ctor
`` ,, ;
:`�., � ' A ..L..._,::,����° > �� �-�
��'�'� • Addressable conventiunal�moke detector
. .;:.. ., . - , ,J'"
_;.��s __--_- __ 1,
-,._ ...- - , • Suitt-in single zone
• Addressabte mo8ule fiar DMP LX 8us
connection
• The 2WT BLX also includes an integra�ed
hea#sensor
+ REd lEb blinks ance�very finre seconds ta
in�i�atP maintenanc�e required
2�1�/-�LX AI�ID 2lIVT BL)C
ADDFiESS�►BLE PFlOTOELECTF�IC S9VfOKE DETECTOFi
SYSTEM FEATiJRES
• Addressable single-point detector module • State-of-the-art opticai sensing chamber
• Fxed-temperature thermal detector trips at 135°F • Easy rotary switch addressing
• Buiit-in drift compensation ensures reliable sensing • Proven design ensures stability and performance
• LED lights speed insta(tation and confirm status
• Reduced wiring and multiple mounting options speed
installation
0
i • • i
�_...__----�� _�____._--____--__
_----�-�5( GLN E-POINT ADDRESSABLE BUILT IN DRiFT COMPENSATION SIMPLIFIED WIRiYVG
YECHNOLOGY As detectors age and accumutate Compared to non-addressable de�ices.
A factory-mounted, addressable singte- contaminants or as their environment addressabledetectorsrequiremuchsimp(er
point zone expander is integrated into the changes, false alarms become more wiring.This type of wiring reduces both
base of the smoke detector.Because each common. With drift compensation, the instaltation time and the chance of errors.
detector reports individually to the panel, detector automatically adjusts to maintain MOUNTING OPTIOfVS
trouble reports are identified to a specific the UL-acceptabte operating range.
detector, speeding repair. No need to Smoothing algorithms compensate for Muttiple optioas provide installation
replace the heads on a string of detectors these changes,reducing nuisance alarms. ftexibiGty. Each detector is supplied with a
or individually test each detector to pinpoint mounting base that can be mounted:
LED STATUS LICHTS
the source of the probtem. • To a single gang box
Wide-angte, duat-color LEDs provide at-
In an alarm situatian, facitity owners and a-glance status indications. After power- • To a 3i'z-or 4-inch octagonal box
first responders instantty know the exact up has comptet2d and the detec#or is • To a 4-inch sqaare hox with plaster ring
location of the alarm, ena6ling a faster {�ndioning normally,the green LED btinks . Directly to the ceiling using drywall
response.For any instatlation that indudes once eve five seconds. If the detector
multi le rooms or areas, addressa6le ry ry fasteners
P needs maintenance 6ecause its sensitivi
technotogy offers many benefits. has shifted outside the timits.the red LED The bases can be pre-wired so the heads
SIMPLIFIED TROUBLESHOOTING blinks once every five seconds. �n be quick{y inserted to complete the
installation.
Addressable detectors provide trouble GREEN LED REO LED
signalsiraceablebacktoaseparatedetector, powe�up Blinksl0seconds Blinksl0se�onds TAMPER RESISTANT
This�urthersimQlifiestroubteshooting and Normal(Stand6y) BGnksSse�onds �� detectors intlude a tamper-resistant
speeds repairs. � feature that prevents removal f�om the
Out ofsensitivily -- Btinks 5 seconds movnting base without the use of a tool.
F1XED TEMPEF�ATURE THERMAL Atarm -- Sntid
DETECTOR EASY ADDRESS(NG
The2WTBLXfeaturesarestorabte.built-in. COMMUNICATION VERIFICATION Settingtheaddressisaseasyasratatingthe
fixed tempereture thermal detectur and is two on-board rotary switches to positions
The verification feature speeds installation
capable of sensing a temperature higher matchingtheLX-Buszonenumberaddress.
than i35°F condition.lf the detector senses ��d ensures system integrity by verifying
a higher temperature than 135°F, the Red the wiring and coniirmi�g devi�e polting
LED tatches on and an alarm condition is using a 2-second�iashing green LED on the
sent to the control panel, integrated zone expander.
SPECIFICATIONS ORDERING INFORMATIOI�!
Ope�ating Vottage 12 VDC •2W-BLX/10 Photoelectric smoke detec�or
Dimensions 5.3'Dia.x 2.0' I
Weigh 6.3 ounces •2WT BW10 Photoelectric smoke detector with fixed-temperature v
Standby Current 11 mA thermal detector o
Atarm CuRent 31mA LISTINGS&APPROVALS �
�
Maximum Ripple 30�M peak to peak Califom'ta State Fire Marshal(CSFM) �
Operating Temperature(Ambient Room) Underwriters Laboratories(UL)Listed - -
2W-BLX 32°F to t 20°F UL 268 Smoke-Automatic Fire Detectors � -
2WT BLX 32°F to 100°F = —
-� —
Humidity Range 0 to 95�RH non-condensing a �
� _
Heat Sensor 135°F(2VJT BLX Onty) o �
Povuer-Up Time 45 seconds � _
Photoelectric Sensitivity 2.5Y1ft.max. � �
m �
'o �
v —
0 �
� -
� - - - 2 a er 'p Boule ar � 2 eo
• - • • �es e n ee e & ssem le
S ' id, sso "65803-8&
in 5 rr gfie s o '
`-:�` :�YDU ,
' '� �
— _____ s
�_"—_----------_._._..__._.________�--___________�--� ,
SECURf�Y ---
SFGHALi��6 �"'' . I
�L k�,�;, `__''---._` ,
� , —
USTED '
1 � �/O�t
_ ... _ _ - -- --_ --- =- - _ - _ = �0911���' �1.1��3�i�S —
_ �
,��.�;.,.�:.:.. - - - - __
�-
��=:.M.«F: {��"�''''�..�>
��..:,;awr��„������, � ��fl��se `/Oft���
� "'' ,,�����.�,,
' ;`x;��'=��,, =�:��; �
��,� �;���, ,.;�"`"�^'',,,"'r$`�.�.�
'�", '��'''x�-='
�
�:�^:�=:�=�:�-- - for any Applica#ion
�.�.--
.�:, ..,.�- : _
. . _ - , . . ° _ �:�.,�,.ry.:,�,.e.Y.��
� rA��., , , _ , , : _ _
��.�:r,-��-_ -
' � � DMiP pow�r suppli�s are� reti�bl�and�rer3atite
�choitP,
'. `✓ • E�#e�tive,cost-eificient i1�power st�ppli��
' " A� t°`� • 5�i�abt�far�ire,acz�ss�antrol,and bur�lary,
� ,�� i•�:r��-�,�:� �I ,� .,�'
� » � v.-':-=="�`� €'-.� I.� N._l� syst��►�pplications
-��A" .:a-'s.���M:.rt
_ _�������tli��`S �.!�Y.r,=
'f.�,���`.'.:-.�.;5.;� - • Per��ct for any 12 VDC application
�_.4,�' �:.
� ,�,�,
`';-` �:•�`i� Frima � Ucations include notification� lrance
;:.d:�a������: � TY PP� PP�
"=��=' �A.. circuit �NA�) �xpansian a�d �uxiliary pov�ier 30
�����''; " � support burglary ahd access cantrol attessories.
��`�-=;:°��:�:�;�.��� I
��.'�yau','�'""w,��'�'r f-
i ��u��u..;.�r'�
.?�"
(.
�='�
t
, . w„*_ .. _ -- - ,,.-..-.-._�-^T-_. � ,i'>
��� �Gil���
��YY�� �����'�a� '
FEATURES
• Reguiated and filtered power system • Rugged cold-ralled steel enclosure
• Power-indicating LEDs • Lock-and-key mechanism for secutity
• Built-in overload protection • Optional tamper switch
• Battery backuplcharging circuit 505-12LX ADDITIONAL FEATURES
• 5 Amp output • Connects to the LX-Bus ofi the XRi00 and XR500 Series
• 12 VDC power supplies • Provides 2 independent Ctass B NAC outputs
• Battery cutoff to preve�t deep discharge of 6atteries
J
. � � • • �
,�_�.���,����...J--���-^-�'�'�
-_�-».
----�''VISUAL INDICATORS 505 SERIES DfGITAL LX-BUS'"" FEATURES
Each power supply provides a green AC The 505 Series power suppties are power The 505-12LX power supplies connect to
power LED and a red DC LED for a visua! limited,switching powersuppliesthat meet the FACP via a 4-wire LX-BusT""(SLC)(oop.
indication of the power suppty input and UL,CSFM,NFPA,and FCC standards. This connection superv�ses communication
output voltage status. The 505-12 provides 5 Amps of continuous between the panet and the NAC modutes.
Charging circuit for a battery backup power. Troubte conditions on the NAC circuit
included with each power supply. 505-12A AND 505-12L (Ground Faulk Open,Short,powersvpplyAC
or Battery trouble)or loss of communication
TRANSIENT PROTECTION The 505-12A is mounted in a gray 350A between the NAC module and the FACP,
AC input and OC output circuits include Grade A, attack-resistant enclosure with cause the specific troubte condition to
metat oxide varistors tMOVs)for transient lock and key and a tamper switch. be indicated at the system keypads and
protection. The 505-12L is mounted in a red or gray 350 reported to the Central Station.
IUONITOR AC lNPUT endosure with lock and key. NAC MODULE FEATURES
The power supplies monitor the AC input 505-i2LX • Providessteady.pulsed.TemporalCode3,
voltage for power failure or 'brownout' The 505-12LX power supplies include and Catifornia Schoots Code bell outputs.
conditions.During AC powerfailure,current all of the features ofi ihe 5D5-12.The LX • Supervised silence switch disables the
is suppGed by the backup battery antil AC version includes two independent Class beUoutputduringserviceormaintenance.
power is restored. B iVAC outputs. Using an 867 Notificafion . On-board status LED indicates good
BATTERY CIOTOFF RELAY Module pro�ides an on-6oard PowerSupply �mmunication with the control pane�
The battery cotoff relay is included to prevent Monitor LED to indipte any loss of power . Rataryswitches provide easyaddressing.
deep-discharge of the battery which helps from the auxiGary powersupply.Atl trouble ACCESSORIES
reduce the risk of damage to the ba�tery or +ndications are communicated to the FACP �
to tfie power suppty itself. via#he 4-wire LX Bus�''digital toop. 8b7 No6fication Modute
• 3D7 Clip-on TamperSwitch
ENCLOSUR� FEATURES • 307-SScre3ns-onTamperSwitch
The power suppiies are mounted and • 3U12Clip-onTar�perSwifch
stabil'rcedinn�ggedendosuresforpratectian • Sealedlead-acidrechargeablebatteries
from the elements.Each enclosure indudes
a tock and keyand provides space to include
a backup battery.Optional tamper switches
may be mounted in the enciosures to
monitor door tannpering.
SPECIFICA'TIOiVS PANEL COMPATIBILITY �
Voltage/Current Input 120 VAC @ 1.5 Amps DMP Power Suppties are compatible with all DMP panels. N
Voltage/Current Output 12 VDC C�5 Amps max. LlSTINGS AND APPROVALS �
�
Califomia State Fre Marshal(CSFM)
Secondary(Battery)Power FCC Part 15 =
Charge Current 1.5 Amps max. Underwriters Laboratories(UL)Listed � _
Current Draw 200mA UL 294 Access Control System Units a �
Only use sealed lead-acid rechargeable batteries. UL 603 Power Supplies for Use witfi Burgtar Atarm Systems o ;
UL 1481 Power Suppties for Fire Protective Signaling -� �
Systems � -
� �
�, —
o =
For addiiional informatian,access www.dmp.com and select Compliance. N _
e —
�
� -- _
• — � — — • — 0 o Pa ne ip ou ev .b4� �8 p eom
ng �{ , 6 803- e Q
�
,
T ,.. , ,,,, _,.'.,,,. ,..,.,,,�:,,,.. � , �..,�.,�,
«r.,..<,. 7n .,, ,. i a ,r,�'.�z^:�:'�r„O/�/Oric�?�o, ._, >..,, //.N'r.�"'Lnr///�.,�,�.��,., ,s„r,!�aDr/OG�;;':.a,;??9���„;,;.^'�A,"%?:�c",•?.%,Sz"""""�?Fr„ 2��6,'�/iria�/!'i��i.�ww"�'7/���
����,.< .:.e�,<,;.r:,�i,,� ,,. . .�.;,,.. .,...�,.. ,r..< ,�",fM. ,r�. �� ,,,..,�, .���/,.,'.�.`,.s'.'".i�. i,;;�./,.>_. z/f— �,�.r,y�. "H�b!�,�,"�r'�'2 fh.�.�H/!/,�.;.�,
i„i... .,,,o�.e,..<,..,.r.,n. ,,.y., .s,,,,.3Ny ��.�/�,„�..ssy':. >„-,.,�..;;7 ;�:"�;.��. ,1'' �u- .�.,' .`,/�,. .L
,,r.c„/ a✓�� �.r��.f�.� ;i� s��i'."'i .. �.. ,;i::. ;r_. �..:
._..,r�,'�. , 7:,-.*. :.,,,i/ �- �;, r, �r�a'��,�, ar� ,�r..J,: "
_..... ,iY/. ,�,.�.d� , ,", .�/ .�, .'Y."„ �%�1.:s:.� a �'i ..f7 a/ ;,:1..7;: ,N:i.,f�jg�%
i ,:: .. ,
,, sii'�/„rll/.� .�,:,�.E> , s_ , ..'->,°., b., .�:�,� �+"� '-Fw/i %": ;i;/:�' ty,.,, �;s%.::,„,Y �:F'
..X,i� ..�ir�� , , ;�o-, . . ,. ,. �„/,.,,,�,F<.,.. . .m,5,/: ��iv io r!�i�!!'.•'�� ��f"�'.�..��� v i?`��:.�>s, l��`" ''F,•�el2i"G;�(%E;;-�, �"4.r.-.�.
� ,b'�P �,:i°S;,
.:,et; ?� „xr i� ,�< r,;�5/,aziG.,., v;-, ':siy, '';�i.,,,, ..iy'-'a L�'"�� y .:b "�' j;_,y/ � �r�i/p�� � .¢"' q�f�a
a2i /-'ii" :' , ;.;;y,y., { � � �. S f 1j�k Z g � >? ,.;�
:i"' ;::r.,�, -%r: '% �% . Fj�:,%��• .�F;j% n i �Y'< :�� %�
�„
� �3 lr �:��/�-� �
�; � e� � �
.% :,.:%;% 1��.:
x.
:y. � ���:�d:;� d.:�cr;
�" ,:� �t�,�:r; �
1� . . .
�:�, ..�� .�._� _.�_
, ;�. , .,. _ �, ,. �.�� ���..��.�... ::� �:
,</ , . ....3,...,.. ,,. ,i.iiv ,r,.,y�� .,,. ,�...,.. , .�:ni,i��.:�fj'..r:nr- %' ��/�.r✓c "^� �/'O/ .,/fl, '�i :.F/'i: i;i5
s� i ri, ./, ., , rr.o / ./ �/�,t ,.a ' '.,
iY , i ,.�. ,.r� i./:,:.;%;:;/1,<�i.�:�.,,�.,�;L/�.� ��.��;7'� ,...��. � �'./y�� ir!_, ,/: �:h���'�
rl�,_.// „�,. :�� „r� .�� ,:.<�`�.. �,�,� ��s, �,,. � ;.�,�.. ;.y ,i o;;_�;�;,
.ti/�.%� in,i.����-�.�., n,>.v. ,�.vzr+ :%f. _,,; .r. �.G..'� ;/�., „� %.��. / i i,�,`�,�%� '�
v�.��� ���.,;:_i�..��. . ...,�(4.�/.ie,rs... .�s� ,''�.':;- ��N, �%Oo' -.'-z'%.J !, ':�%� �, .,F�' ,pv./� p�%�
,,.���
/ � -/c �;%� �. Oii.a:�;i:'
,. _:��/ �/;,�,..,,.,.�; ,�� .:%�,,.�,.,.,r %:o:`%�,,-x�3. /<u.�:�i, i/>,l_ yi�4 j%j�/� ��;;; �i./1�/�,,;c,r.L,„l>:,.�i
,
-,,.-i�q o��/./„r.�,.,, . .. ., , ,i. ,,.�z,. .. �, ,>, .,���, ,� %,,,�.,:G�'w�� ,-,,lo��„^ �r'/�,'�,l„�� _1�.����'', . .,r,,,,
-i. ."R'.!N,..�.,i. , .:- ./,?'/N.,,O.�s:f';c��ir,/.rL,.r,,;i�i� ii7".��¢:���� �,�� .','/�f':l �i�::.: ,. ,.�i i„ / .>.�
„�.5r%,;�j.�. .r� / 3�/:��.���ihf.UW,r ' i � ,
i�, " .,, ., �.,..,..'�.,,i. .i/.. . C//... �, /'�./i. „'.�Y/�j,�%y'',"; ..�/,/r.�%ji'."l '�"(.,.: r�'P�•��/N !;�i�i�i� :�
,�� � .'�/,��//G.°' ;%,; i%r;/.: ✓�i� '�l':../� ;'✓./.' i�,.i
,/„�. L.,�,�rk-;:� ..ie,-/-,: .<�,,;;iv�io; ,�;�:i' �.i�:'� �U�,;,v >:�<,,,� ;°�.,
�5;{;' ,.<��,.,,���,`„ .. <,ii�� ,. .,li,�,., ',;�
.�;, a ` 3 ,� , n ation ;witli>re ard'to-size�am"*'hou�,r,atin ;:and;.:?�y
. . ,
„ELK"Sealed Leacl..Acid Batte:�es ar.e�zcell,"en�.forthefol��w�ri :a '�lic g, ,,..,,,...p�.. <.X,,,.,,,. g•,,,,,,
>,., ..� :,. .., 9.,,,... ,,..,_ .�,., ,�,.�,,, ..,.:,,N,,,
.�:,, , r . ,., .P,.,. ,. , . , . . . :.... .:. ...fr:f.;-. ,.>..i;.,,,�:�g,..;�..s �f7',�jy,ma.* eYc�/,. ;�-�.%/�i � :;,�%ir�;`x,/. 'x��:X.E
n, .q . .F: , / ..r.{r. .,,.,:.;r:, y� / ,�. ,..:/....,�.a.zf�,.. ,S% �:v�t:a -'%r; �''1,�:iNr�?-ra ,'nr zi.,:.vµ,..,r..�gr j.,,;.:
,;y.;....,.,, ., ,,./.,.s/,� ..�..��. .,,r��. �,� ,r. 9aJr;r% .i�'" ;;ii' i.�.6 ,�� ,/�
i✓::.. .::. . .. . .. ..rri��/,., . ... . �,%; /�.q. �,: ,.`: `,P
..:�r�� ..._...e� # y�t �.(
vi, ...,1i,.-, .��f�� ���� �i '.;'j'~�: �.C�iG�;��lr3- S`�i:t is`�:��U:,S����. . .�f.��.�i%,,
.�,�r , r term -al,�conn�ect���ki"at��r.. ��"`"c�r�`F(for��ces�;�o'%itro#,,s �tern ,.frr� y, t
„ . ..;�.,�' . .,,..,.�,,..,:,., ,,,,,: .,,, .,. . ...,..,.,,. 1F . : ::,�. .,.r<. ,),i a,a, !o::;;i �,,.�"5.��., �,;�,,�,�
� .,a..�i.,. . ,.a,,:�, -,s,. „y,,,.�<��q,:✓ . . ...; :.,,.,,... . ,�.:u�.'- . �r,:q zr., ;..;::^ 7s�� .,yi.; �.z;��rE,�,y, ,1.,. rr"'G„ ,,e
,.:G�..�... ie - , , ,r ,; ir.,5,, ,,.;..'�.,;../.
,, ., F
. c,.<,,,..,.r;..��, ,. .y . ,. :�.:�s „�,- ./:-,..,. ,:;y,f,:/,,./,., .� ,<., rl�,,�'��'` ,e.:%�-xi,i,s� �Z6,';;i v �v ;.%ii'f,, ,✓..��../.2/::-,��,/"�.d.r;.i
;,E,.as...r,,-,�. • .,,.. .. �<.,., . :�..viU.i,./,.,:.
� . . . ..,.���,,.. . ,r ' � '. ,, :%"zs�;¢ ;" ;;,; -.. ;., �
r�call :mota�ze:d;vehicl.es�`emer enc ;li`'hts:li hted�exi�si ns;;and;'utiiriter,ru t�k�1e :ov,rer�s;. .plies:-;r
�- systems};elect y, 9:. Y,>.,.�., 9 ,9 ,y ,p., �?,,F.. K� �
,.; ,...,.,,..,,;:.;.. , .-_y., . ..,.;. ; , ,, ,;,., ;:o:. ����� ,.. ��.:.,,..
' � .r:� :�:.rro�:�//,/,�/,: ;j!r� i,j�".,�'.i.�F),v �.,� f.,:
;�., ,.:., ,;�sa;H�...„ ..,....,,w.,�/, ;>/.,� �:
�.;.:.. ,.1'-
, "
.✓,,. „b,:f f`?; a:aN
.. �, -s�., �:. ,.r.. .. , .. .,, �:�-,.,....,. .F„,as�,..:
/ ,: o�:.
, ....,.9 ., , ... �. „i 3 n,... . ,,;,i.,. ;r.iv.,-,, r. ,:ii.,�u'�i.,-':i n��i�w%�:.�
, „Y.s. ,.,. :. , , ..- - .. .... ,r., .� y..r.� ,. ....F.r, ., :. . . �,.:.✓d,f%",` � " „�/s'.. �,T . .,j..�.,u`u'.'�qw`n��%U��;s'.,,�ea,z».w.,4.�._
�.F.wsG.��'2/v�,G.�<�Cau.....�<..,.,.,:_..,,,,..,...,._.,.„».....,,,..,,,r.,s�i���.w�Ga_.�,,,.a,..ik✓�i;;Z.��`e.rsi�s�.,....,...<...st..,nir.�,.r,,,_�__,:�.;«.Cw<.;.......�'u<�:,�,...�.ti,�v.'r".,"o;.o.��.,.r;Fh:ii////n�,w�%.;:�'r'�,�.`.,,..,....�,..�Gu,�r,r..,�.. :»
, % `"�
ELK-1 ��� 12Vd � l�h
. , .
�► �;
.....
Nominal Voltage 12 VOItS .. ������� ,' . � UCompo elntd
Rated Capacity 8 Ah(20 hour rate) ��� �� %"`�' �
,,..._.�....._.,..... ,..
„ �a,�,, ���� :.:. i
Length 5.94 (151 mm) ��
Width 2.56"(65 mm) ��� �
� Neight 3.98"(10l mm� � �
€
Weight(Approximate) 5.6 Ibs(�.5 kg) 974'o Recyttable �
� Terminals F1 Fastan Tab(.187") �
�
. � . A � Dimensions(�nm) �
�
Capacity 20 hour rate(Q.375A) 8Ah F� �
77°F(25°C) 10 hour rate(0.71 A) 7.1Ah �'�� �
a.,� �
5 hour rate(1.27A� 6.37Ah � �
�
, �'��a,_��...� �
1 hour rate(4.5A) 4.5Ah ����'T e �
e ,
�� f
Capacity affected 104°F�40°C} 102°l0 �
t�yTemperature 77°F(25°C) 100% �_.,,_._.._.. 1S1 —._�.._.._...__.� �-.. .._- �,s ---{ �
(20 hour rate) 3�°F(0"C} 85°l0 �� __. � ' � �
� 5°F(-15°C) 65°/a ' �o �=__.�__ �
Charge Constant Cycie: initial Charging Current(ess than 2.25A '' �
Voltage Voltage 14.4V-15.OV at 77°F(25°C) � � �
Standby: Voltage 13.5V-13.8V at 77°F(25°C} -�.. __.._---_____..._._ ; ,�.._..__.. _ ��
----...._.... _ _____.. �._�__.. _.__�..,�._.—.. �
�
Discharge Ch�ra�eterist�cGs (2U'C,S$°F) Discharge C'haracteristics {U°C/32°F,d0°CI1Q4� '�
�� ��
s �
�Z T � �
�
�� �
� " � � �
-�,a�n o:7�i a��n d :�
y '� � �
� . � za
�
� 4 4 fi � fA°�b3# A°C(32°ti 30°C 104°F)
� � �+ � i
� $ -t'�' � � �
37SA 30s122.5A 15A 7.�A� � i
( �
�l 2 3 S tA 2(t Stl bi) 2 3 5 t9 26 3D 3U45M� 1�3 1S 3it � i
y, �.__.' (min) _—_""._`�_"' {l�) -j �"_(mA)—}--{A)----� �
Uischarge Ti�n+� i)isc�rge Carrent �
�l�� �
�
� Far more inforrrration,including detar/s on recycling ELK batteries and N1SDS for �
PRODIJCTS this product,please visit www.elkproducts.com or call us at(828)397-4200. �
,�.. .M.,.� �m,,,,, .,..,.,,.,µ,.H.� , ,w. ..�,.�,.��� . ._„ » ..�..w,.,
. ,
; ,� DTK-HW Series �
;;
f �� y � Equipment Pane//Dedicated Ci�cuit Su�ge P�otective Device
`��"DITEK Gene�a/P�oduct Specifications
y� �
DITEK's HW series of surge protectors are designed -��°� ����-,
and manufactured to meet the exacting standards of �M" �� � '� ""' `���-�-w,
the life safet indust These com act tx" ' �'�'�����t. '
y ry. p parallel ' �
mount surge protectors are widely used to protect ��
fire alarm panels and other dedicated branch circuit
.��
loads. %
-,���°%%
DTK-120HW DTK-120/240HW � � � �
, , ,
Product Features ' ' "
. � � .
•Available for Popular 120V and 120/240V systems
• DTK-120HW approved for 20A circuit breakers �,�
• Diagnostic LED indicates ground presence, �
system power and SPD function � �
•Weatherproof enclosure
• Small footprint enables installation in a variety of ��
locations
•Available for popular 120V, and 120/240V systems �
• Complies with ANSI/IEEE C62.41 and C62.45 Specifications
Category B standards Agency Approvals: UL 1449, 3�d Edition, cUL
•Ten Year Limited Warranty IEEE Location Category: Category B
�'���-�� � -r- Protector Type: SPD Type 2
� __ ���, � Protection Modes: L-G, L-N, N-G
�� ; Response Time. 1 ns
s_��--= ,_,�. Temperature Range: -40°F— 185°F (-40°C—85°C)
�.._...,,�..._.._... Maximum Humidity: 95% non-condensing
, -m,--- - Operating Frequency: OHz—400Hz
,__��:.`c?� ----..t�
�.��:� ----�----m------ Dimensions: 2.93"x 2.83"x 1.68"
� � � (74.4mm x 71.9mm x 42.7mm)
�9 Connection: 3/4" diameter threaded fitting
; Weight: .51b. (227g)
.�... --_.�.W..�.. . ...�����
� �����~ Housing: ABS
„S..
��
r _ �
Model Peak UL 1449, 3�d Short Circuit UL1449,
seiect�on: Service Wiring Surge MCOV Current 3�d Ed. I�
°TK- Current Ed. V.P.R. Rating Rating
120HW Single� 19,500A 130V �OOV L-N, L-G; 10,OOOA 3,OOOA
(2W+G), 120VAC 600V N-G
13,OOOA/ 700V L-N, L-G;
120/240HW Split�p Phase 130/260V 600V N-G; 10,OOOA 3,OOOA
(3W+G), 120/240VAC 6,500A/ 1200V L-L
Mode
C UL US
One DITEK Center 1-800-753-2345 Document: SPS-100057-001 Rev 10 9/13
1720 Starkey Road Technical Support: 1-888-472-6100 002013 DITEK Corp.
Largo, FL 33771 www.ditekcom.com Specification Subject to Change
N E W G E N E R A T f O N�' C A B L E S 20.55
Fir� A1a�rm �abl�
Gommercial Applications �� >>>
Unshielded, Pawer-�imited NEWGENERATiON"
Unshielded Multi-conductor . ,.B;I •„ . ,. , . , � . ��
FPLR/CMG FT4 Rated � � . � � - � � - �
� t � ��
Product Desc�ip#i�are
Bare copper cpnduatars,PVC insuiation, Unshi�lded Mul4i-�oreductar{NEC FPLR and CEC CMG F'f4)
conductors cabfed together, Red PVC
jacket with rip card.Sequential footage 5522UL 4 solid C-500 C-152 7.0 3.2 .01 q .25 125 3.18 "
marking every two#eet. U-1040 U-305 16.4 7.3
1d00 305 16.0 7.3
Color Code:See chart below. 5524U4 6 solitl C-500 C-152 10.0 4.6 .010 .25 168 4.27
Specafic�t6ons U-100� U-3D5 21.d 9.5
Conductar Bare CopPQ� 532DUL 2 solid C-500 C-152 8.0 3.6 .010 .25 .151 3.84
Insulation PVC ll-5d� U-152 9.d 4.1
Jacket PVC 500 152 9.0 4.1 _
U-1000 U-305 18.0 8.2
Jacket Thickness .015"{.381 mm) 1000 305 17.� 7,7
Appravals 5322UL 4 solid C-250 C-76 7.0 3.2 .010 .25 .176 4.47
NEC FPLR C-500 C-152 14.4 6.q
CEC{22-16 AWG only} GMG FT4 U-50{l U-152 15.5 7.4
California State Fire Marshall U-1000 U-305 30.0 13.6 ,
NEC Aniotes 764 10�0 305 30.0 13.6
Voltage Rating 300V 5324UL 6 soSid 50d 152 23.5 10.7 .010 .25 212 5.38
Temperature Rating 75�� U-1�00 U-305 43.0 19.5
1044 305 44.0 20.p
lipplications 532&Ul 8 solid 1000 3d5 Bi.O 277 .OiO .25 .230 5.84
• Fire Protection 5328UL 10 solid 1000 305 71.0 32.3 .010 .25 .272 6.91
• Aiarm 5329U� 12 so3id 1000 305 83.0 37? .010 .25 .281 7.19
• Signal 5220U1.' 2 solid 5Q0 152 13.0 5.9 .010 .25 174 4.42
• MonitorlDetec#ion U-1000 U-3d5 24.0 10.9
• Audio Circui#s 1000 305 25.0 11.4
• Confrol Gircuits 5222U� 4 solid 1400 3d5 45.d 20.4 .010 .25 .204 5.18
• Initiating Circuits
• Natification Gircuits 5120UL* 2 solid 500 152 19.0 8.6 .013 .33 .213 5.41
10Dd 305 38.0 17.3
5122UL 4 solid 1000 305 70.0 31.8 .013 .33 .251 6.38
5020UL 2 solid 10d0 305 55.0 25,0 .013 .33 .2A7 6.27
'Also available in other jacket colors.Consult vnvw.belden.com,
Colar Code Chart
� ��t� �
1 Black
2 Red
8 Brown
4 Blue
5 Orange
8 Yellow
7 Putple
8 Green
9 RedlBlack
10 RedlWhite
11 Red/�reen
32 Red1Blue
������ For mare inEormation, contaot Sslden Technicai Support• 1-804-8E�QECd-1 • www.beiden com